TITLE: 05/01 Day Shift: 15:00-23:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Observing at 151Mpc
OUTGOING OPERATOR: Corey
CURRENT ENVIRONMENT:
SEI_ENV state: CALM
Wind: 4mph Gusts, 2mph 5min avg
Primary useism: 0.01 μm/s
Secondary useism: 0.13 μm/s
QUICK SUMMARY: Just got back into Observing after a lock loss, fully auto relock. Planned commissioning today from 9-12 PT
After yesterday's SQZ realigning 77530 we're nearly back to the squeezing levels we had before the output arm alignment shift 77427: 4.3dB above 1kHz, 3.3dB ~350Hz. Plot attached.
I made a small change to verbal_alarms tests in test.py to ignore the TEST node being in error as I plan on creating another state to test/learn some camera stuff and I don't want to annoy everyone in the CR with it going into error. Verbal alarms could use a restart to reflect these changes.