########################### HAM-ISI Update ########################### START: 3:24PM on Feb 12th 2014 - LHO aLog # 10032 FINISHED:6:20PM WP: 4434 3:25PM - ISI fully turned off 3:38PM - svn up 4:09PM - Restarted HAM2 4:32PM - Updated resetWatchdogThresholds 4:36PM - HAM2-ISI fully updated was tested and it is isolated again 4:46PM - Updated version of h1isiham2.mdl gets commited to the svn -r7102 4:51PM - Restarted HAM3 after updating model. 5:30PM - All models are restarted. HAM3 needs to be restarted again once Alexa is done with her measurement 5:58PM - Updated foton files for HAM2 and HAM3 so ISO Lv3 starts in filter module FM3 instead of FM2. Needed for the command scripts to work 6:20PM - HAM2 and HAM3 are fully isolated. Alignment and isolation performance are similar to what they were prior to the update. ************ SVN Up ************ controls@opsws2:common 0$ pwd /opt/rtcds/userapps/release/isi/common controls@opsws2:common 0$ svn st ? scripts/wd_plots/test.pl ? scripts/wd_plots/ST2_CPSINF.cmd ? scripts/wd_plots/ST2_GS13INF.cmd ? scripts/wd_plots/plot.sh ? filterfiles/ISI_4k_FIR_companion_filters_ST2_SENSCOR_20130509.mat ? guardian/HAM/states/SAFE/transits ? guardian/HAM/states/SAFE/goto controls@opsws2:models 127$ pwd /opt/rtcds/userapps/release/isi/common/models controls@opsws2:models 0$ svn up isihammaster.mdl U isihammaster.mdl Updated to revision 7097. controls@opsws2:medm 0$ pwd /opt/rtcds/userapps/release/isi/common/medm controls@opsws2:medm 0$ svn up hamisi/ U hamisi/ISI_CUST_CHAMBER_WATCHDOG.adl D hamisi/ISI_CUST_CHAMBER_SENSCOR_MATCH_L4C_ALL_BAK.adl D hamisi/ISI_CUST_CHAMBER_ERRMON.adl D hamisi/ISI_CUST_CHAMBER_SENSCOR_FIR_L4C_ALL_BAK.adl D hamisi/ISI_CUST_CHAMBER_OVERVIEW_LARGE_BAK.adl D hamisi/ISI_CUST_CHAMBER_SENSCOR_IIRHP_L4C_ALL_BAK.adl D hamisi/ISI_CUST_CHAMBER_OVERVIEW_BAK.adl D hamisi/ISI_CUST_CHAMBER_ST1_SENSCOR_OVERVIEW_BAK.adl D hamisi/ISI_CUST_CHAMBER_SENSCOR_OVERVIEW_BAK.adl U hamisi/ISI_CUST_CHAMBER_COMMANDS.adl U hamisi/ISI_CUST_CHAMBER_OVERVIEW.adl Updated to revision 7097. controls@opsws2:scripts 0$ pwd /opt/rtcds/userapps/release/isi/common/scripts controls@opsws2:scripts 0$ svn up HAMISItool U HAMISItool Updated to revision 7097. controls@opsws2:scripts 0$ pwd /opt/rtcds/userapps/release/isi/common/scripts controls@opsws2:scripts 0$ svn up HAMISItoolwrapper.sh At revision 7097. controls@opsws2:scripts 0$ svn up wd_plots/ A wd_plots/random_retry.patch U wd_plots/util.py U wd_plots/main.py U wd_plots/const.py Updated to revision 7097. controls@opsws2:common 1$ pwd /opt/rtcds/userapps/release/isi/common controls@opsws2:common 0$ svn up U src/ISIWD_GPS.c D guardian/stateMaker D guardian/lib D guardian/BSC A guardian/cartbias.py A guardian/HAMX.py D guardian/HAM svn: Failed to add directory 'guardian/HAM': an unversioned directory of the same name already exists controls@opsws2:common 1$ ************************* Update model for HAM2 ************************* IOPWD input grounded because CDS update is still waiting for ECR approval. Will need to be updated once CDS is ready (next week or so) ************************* Compile/restart HAM2 ************************* controls@h1build release 0$ make h1isiham2 command is make h1isiham2 Cleaning h1isiham2... Done Parsing the model h1isiham2... Done Building EPICS sequencers... Done Building front-end Linux kernel module h1isiham2... Done RCG source code directory: /opt/rtcds/rtscore/advLigoRTS-2.8.2 The following files were used for this build: /opt/rtcds/userapps/release/cds/common/models/ODCV2.mdl /opt/rtcds/userapps/release/cds/common/models/ODC_CHAN.mdl /opt/rtcds/userapps/release/cds/common/src/BLRMSFILTER.c /opt/rtcds/userapps/release/cds/common/src/ODC_ADD_PARITY_INT.c /opt/rtcds/userapps/release/cds/common/src/ODC_LATCH.c /opt/rtcds/userapps/release/cds/common/src/wait.c /opt/rtcds/userapps/release/isc/common/models/ISC_common.mdl /opt/rtcds/userapps/release/isi/common/models/Offset_DOF.mdl /opt/rtcds/userapps/release/isi/common/models/WD_Checker.mdl /opt/rtcds/userapps/release/isi/common/models/isihammaster.mdl /opt/rtcds/userapps/release/isi/common/models/isipayloadwd.mdl /opt/rtcds/userapps/release/isi/common/src/BLENDDIFF.c /opt/rtcds/userapps/release/isi/common/src/BLENDMASTER.c /opt/rtcds/userapps/release/isi/common/src/ISIRESET.c /opt/rtcds/userapps/release/isi/common/src/ISIWD_GPS.c /opt/rtcds/userapps/release/isi/common/src/LATCH.c /opt/rtcds/userapps/release/isi/common/src/RAMP_BIAS.c /opt/rtcds/userapps/release/isi/common/src/WD_CHECKER.c /opt/rtcds/userapps/release/isi/h1/models/h1isiham2.mdl Successfully compiled ********************* make succeeded log file is /opt/rtcds/lho/h1/data/buildlog/h1isiham2_2014_06_12_16:06:45 $ controls@h1build release 0$ make install-h1isiham2 command is make install-h1isiham2 Installing system=h1isiham2 site=lho ifo=H1,h1 Installing /opt/rtcds/lho/h1/chans/H1ISIHAM2.txt Installing /opt/rtcds/lho/h1/target/h1isiham2/h1isiham2epics Installing /opt/rtcds/lho/h1/target/h1isiham2 Installing start and stop scripts /opt/rtcds/lho/h1/scripts/killh1isiham2 Performing install-daq Updating testpoint.par config file /opt/rtcds/lho/h1/target/gds/param/testpoint.par /opt/rtcds/rtscore/advLigoRTS-2.8.2/src/epics/util/updateTestpointPar.pl -par_file=/opt/rtcds/lho/h1/target/gds/param/archive/testpoint_140212_160748.par -gds_node=56 -site_letter=H -system=h1isiham2 -host=h1seih23 Installing GDS node 56 configuration file /opt/rtcds/lho/h1/target/gds/param/tpchn_h1isiham2.par Installing auto-generated DAQ configuration file /opt/rtcds/lho/h1/chans/daq/H1ISIHAM2.ini Installing Epics MEDM screens Running post-build script /opt/rtcds/lho/h1/medm/h1isiham2/H1ISI_HAM2_PAYLOADMON.adl /opt/rtcds/userapps/release/isi/common/scripts/create_hamisi_payload_with_links HAM2 MC1 MC3 PRM PR3 make succeeded log file is /opt/rtcds/lho/h1/data/buildlog/install-h1isiham2_2014_07_12_16:07:48 controls@h1build release 0$ #################################### Tests Update on HAM2 #################################### 1- Make sure that Overview & WD screen got updated: No white lines 2- Trun on damp and ISO and see it isolate 3- FF blocks are grey (no filter loaded) 4- Tripped the ISI by lowering Threshold on CPSs. 5- Made sure that CPSs get recorded as the last group of sensors that tripped the ISI. 6- Made sure that Last WD trip time gets recorded 7- Confirmed that "reset threshold levels" buton resets the watchdog threshold to the safe values 8- Made sure that "Reset all" button resets both the user WD and the dackill 9- Repeated 4-8 with GS13 and ACT ##################################### Commit new version of h1isiham2.mdl #################################### controls@opsws2:models 0$ svn st M h1isiham2.mdl controls@opsws2:models 0$ svn commit -m "updated master model and re-wired the top level model of HAM2-ISI accordingly" h1isiham2.mdl Sending h1isiham2.mdl Transmitting file data . Committed revision 7102. ################################################## Repeat previous steps for HAM3 HAM4 HAM5 and HAM6 ################################################## controls@opsws2:models 0$ pwd /opt/rtcds/userapps/release/isi/h1/models controls@opsws2:models 0$ svn commit -m "updated HAM-ISI top level model to match the latest version of the master model." * Sending h1isiham3.mdl Sending h1isiham4.mdl Sending h1isiham5.mdl Sending h1isiham6.mdl Transmitting file data .... Committed revision 7104.