controls@h1build release 0$ make h1isiham4 command is make h1isiham4 Cleaning h1isiham4... Done Parsing the model h1isiham4... Done Building EPICS sequencers... Done Building front-end Linux kernel module h1isiham4... Done RCG source code directory: /opt/rtcds/rtscore/advLigoRTS-2.8.2 The following files were used for this build: /opt/rtcds/userapps/release/cds/common/models/ODCV2.mdl /opt/rtcds/userapps/release/cds/common/models/ODC_CHAN.mdl /opt/rtcds/userapps/release/cds/common/src/BLRMSFILTER.c /opt/rtcds/userapps/release/cds/common/src/ODC_ADD_PARITY_INT.c /opt/rtcds/userapps/release/cds/common/src/ODC_LATCH.c /opt/rtcds/userapps/release/cds/common/src/wait.c /opt/rtcds/userapps/release/isc/common/models/ISC_common.mdl /opt/rtcds/userapps/release/isi/common/models/Offset_DOF.mdl /opt/rtcds/userapps/release/isi/common/models/WD_Checker.mdl /opt/rtcds/userapps/release/isi/common/models/isihammaster.mdl /opt/rtcds/userapps/release/isi/common/models/isipayloadwd.mdl /opt/rtcds/userapps/release/isi/common/src/BLENDDIFF.c /opt/rtcds/userapps/release/isi/common/src/BLENDMASTER.c /opt/rtcds/userapps/release/isi/common/src/ISIRESET.c /opt/rtcds/userapps/release/isi/common/src/ISIWD_GPS.c /opt/rtcds/userapps/release/isi/common/src/LATCH.c /opt/rtcds/userapps/release/isi/common/src/RAMP_BIAS.c /opt/rtcds/userapps/release/isi/common/src/WD_CHECKER.c /opt/rtcds/userapps/release/isi/h1/models/h1isiham4.mdl Successfully compiled ********************* make succeeded log file is /opt/rtcds/lho/h1/data/buildlog/h1isiham4_2014_50_14_10:50:45 controls@h1build release 0$ controls@h1build release 0$ controls@h1build release 0$ controls@h1build release 0$ make install-h1isiham4 command is make install-h1isiham4 Installing system=h1isiham4 site=lho ifo=H1,h1 Installing /opt/rtcds/lho/h1/chans/H1ISIHAM4.txt Installing /opt/rtcds/lho/h1/target/h1isiham4/h1isiham4epics Installing /opt/rtcds/lho/h1/target/h1isiham4 Installing start and stop scripts /opt/rtcds/lho/h1/scripts/killh1isiham4 Performing install-daq Updating testpoint.par config file /opt/rtcds/lho/h1/target/gds/param/testpoint.par /opt/rtcds/rtscore/advLigoRTS-2.8.2/src/epics/util/updateTestpointPar.pl -par_file=/opt/rtcds/lho/h1/target/gds/param/archive/testpoint_140214_105113.par -gds_node=61 -site_letter=H -system=h1isiham4 -host=h1seih45 Installing GDS node 61 configuration file /opt/rtcds/lho/h1/target/gds/param/tpchn_h1isiham4.par Installing auto-generated DAQ configuration file /opt/rtcds/lho/h1/chans/daq/H1ISIHAM4.ini Installing Epics MEDM screens Running post-build script /opt/rtcds/lho/h1/medm/h1isiham3/H1ISI_HAM3_PAYLOADMON.adl /opt/rtcds/userapps/release/isi/common/scripts/create_hamisi_payload_with_links HAM3 MC2 PR2 make succeeded log file is /opt/rtcds/lho/h1/data/buildlog/install-h1isiham4_2014_51_14_10:51:13 controls@h1build release 0$ userapps controls@h1build release 0$ ls als aos asc cds ecat etc fmcs guardian hpi ioo isc isi lsc omc pem psl saf sus sys tcs ve controls@h1build release 0$ cd cds/common/scripts/ controls@h1build scripts 0$ ls add_args_to_adls.py beckhoff_gang_whiten checkTargetDependencies dolphin_present.sh dumpTargetDependencies gen_awgtpman_scripts.sh gpsget makeSafeBackup openDTT.py rt.sh something.adl start_streamers.sh webview.log awgtpman_monitrc_template cat_medm.py check_filter_file_hard_links.bsh dolphin_wait edcu.sh generate_KisselButton.py kill_epics.sh medm_expander.py pyburtfile rtsystab start_epics.sh topodiff.py webview_simlink_update.m awgtpman_template checkCompiledModel daily_restart_logger.sh dolphintab ezcaswitch generate_KisselButton_with_alarms.py kill_fes.sh medm_gen2specific.pl rc.local setup_RCG_LIB_PATH.sh start_fes.sh update_webview.cron which_matlab_version.py beckhoff_gang_gain checkSafeDotSnapFiles.sh demacrotize_medm_screen.py dtt2mlab filter_checker generate_ini_req_file.py load_dolphin_drivers.sh medm_macro_finder.pl reserve slow_chan_config_checker.py start_iop_mx_stream.sh view_alarms.pl controls@h1build scripts 0$ controls@h1build scripts 0$ controls@h1build scripts 0$ controls@h1build scripts 0$ makeSafeBackup isi h1isiham4 H1:FEC-61_IPC_SUS_SR2_ISI_HAM4_WD_ER ... not connected so no ca_array_get_callback() H1:FEC-61_IPC_SUS_SR2_ISI_HAM4_WD_ET ... not connected so no ca_array_get_callback() H1:FEC-61_IPC_SUS_SR2_ISI_HAM4_WD_PS ... not connected so no ca_array_get_callback() H1:ISI-HAM4_PAYLOAD_SR2_TRIP_FLAG ... not connected so no ca_array_get_callback() H1:ISI-HAM4_PAYLOAD_SR2_RUNNING ... not connected so no ca_array_get_callback() H1:ISI-HAM4_PAYLOAD_SR2_OVERRIDE_LATCH ... not connected so no ca_array_get_callback() H1:ISI-HAM4_PAYLOAD_SR2_OVERRIDE ... not connected so no ca_array_get_callback() H1:ISI-HAM4_PAYLOAD_SR2_BLOCK ... not connected so no ca_array_get_callback() H1:ISI-HAM4_PAYLOAD_TRIP_FLAG ... not connected so no ca_array_get_callback() H1:ISI-SR2_ISI_HAM4_WD_ERROR ... not connected so no ca_array_get_callback() H1:FEC-61_IPC_SUS_SR2_ISI_HAM4_WD_ER.HSV ... not connected so no ca_array_get_callback() H1:FEC-61_IPC_SUS_SR2_ISI_HAM4_WD_ER.LSV ... not connected so no ca_array_get_callback() H1:FEC-61_IPC_SUS_SR2_ISI_HAM4_WD_ER.HIGH ... not connected so no ca_array_get_callback() H1:FEC-61_IPC_SUS_SR2_ISI_HAM4_WD_ER.LOW ... not connected so no ca_array_get_callback() H1:FEC-61_IPC_SUS_SR2_ISI_HAM4_WD_ET.HSV ... not connected so no ca_array_get_callback() H1:FEC-61_IPC_SUS_SR2_ISI_HAM4_WD_ET.LSV ... not connected so no ca_array_get_callback() H1:FEC-61_IPC_SUS_SR2_ISI_HAM4_WD_ET.HIGH ... not connected so no ca_array_get_callback() H1:FEC-61_IPC_SUS_SR2_ISI_HAM4_WD_ET.LOW ... not connected so no ca_array_get_callback() H1:FEC-61_IPC_SUS_SR2_ISI_HAM4_WD_PS.HSV ... not connected so no ca_array_get_callback() H1:FEC-61_IPC_SUS_SR2_ISI_HAM4_WD_PS.LSV ... not connected so no ca_array_get_callback() H1:FEC-61_IPC_SUS_SR2_ISI_HAM4_WD_PS.HIGH ... not connected so no ca_array_get_callback() H1:FEC-61_IPC_SUS_SR2_ISI_HAM4_WD_PS.LOW ... not connected so no ca_array_get_callback() H1:ISI-HAM4_PAYLOAD_SR2_TRIP_FLAG.HSV ... not connected so no ca_array_get_callback() H1:ISI-HAM4_PAYLOAD_SR2_TRIP_FLAG.LSV ... not connected so no ca_array_get_callback() H1:ISI-HAM4_PAYLOAD_SR2_TRIP_FLAG.HIGH ... not connected so no ca_array_get_callback() H1:ISI-HAM4_PAYLOAD_SR2_TRIP_FLAG.LOW ... not connected so no ca_array_get_callback() H1:ISI-HAM4_PAYLOAD_SR2_RUNNING.HSV ... not connected so no ca_array_get_callback() H1:ISI-HAM4_PAYLOAD_SR2_RUNNING.LSV ... not connected so no ca_array_get_callback() H1:ISI-HAM4_PAYLOAD_SR2_RUNNING.HIGH ... not connected so no ca_array_get_callback() H1:ISI-HAM4_PAYLOAD_SR2_RUNNING.LOW ... not connected so no ca_array_get_callback() H1:ISI-HAM4_PAYLOAD_SR2_OVERRIDE_LATCH.HSV ... not connected so no ca_array_get_callback() H1:ISI-HAM4_PAYLOAD_SR2_OVERRIDE_LATCH.LSV ... not connected so no ca_array_get_callback() H1:ISI-HAM4_PAYLOAD_SR2_OVERRIDE_LATCH.HIGH ... not connected so no ca_array_get_callback() H1:ISI-HAM4_PAYLOAD_SR2_OVERRIDE_LATCH.LOW ... not connected so no ca_array_get_callback() H1:ISI-HAM4_PAYLOAD_SR2_OVERRIDE.HSV ... not connected so no ca_array_get_callback() H1:ISI-HAM4_PAYLOAD_SR2_OVERRIDE.LSV ... not connected so no ca_array_get_callback() H1:ISI-HAM4_PAYLOAD_SR2_OVERRIDE.HIGH ... not connected so no ca_array_get_callback() H1:ISI-HAM4_PAYLOAD_SR2_OVERRIDE.LOW ... not connected so no ca_array_get_callback() H1:ISI-HAM4_PAYLOAD_SR2_BLOCK.HSV ... not connected so no ca_array_get_callback() H1:ISI-HAM4_PAYLOAD_SR2_BLOCK.LSV ... not connected so no ca_array_get_callback() H1:ISI-HAM4_PAYLOAD_SR2_BLOCK.HIGH ... not connected so no ca_array_get_callback() H1:ISI-HAM4_PAYLOAD_SR2_BLOCK.LOW ... not connected so no ca_array_get_callback() H1:ISI-HAM4_PAYLOAD_TRIP_FLAG.HSV ... not connected so no ca_array_get_callback() H1:ISI-HAM4_PAYLOAD_TRIP_FLAG.LSV ... not connected so no ca_array_get_callback() H1:ISI-HAM4_PAYLOAD_TRIP_FLAG.HIGH ... not connected so no ca_array_get_callback() H1:ISI-HAM4_PAYLOAD_TRIP_FLAG.LOW ... not connected so no ca_array_get_callback() H1:ISI-SR2_ISI_HAM4_WD_ERROR.HSV ... not connected so no ca_array_get_callback() H1:ISI-SR2_ISI_HAM4_WD_ERROR.LSV ... not connected so no ca_array_get_callback() H1:ISI-SR2_ISI_HAM4_WD_ERROR.HIGH ... not connected so no ca_array_get_callback() H1:ISI-SR2_ISI_HAM4_WD_ERROR.LOW ... not connected so no ca_array_get_callback() Created the following soft link in the target area: lrwxrwxrwx 1 controls controls 64 Feb 14 10:52 /opt/rtcds/lho/h1/target/h1isiham4/h1isiham4epics/burt/safe.snap -> /opt/rtcds/userapps/release/isi/h1/burtfiles/h1isiham4_safe.snap Please check the following file into SVN: -rw-rw-r-- 1 controls controls 893261 Feb 14 10:52 /opt/rtcds/userapps/release/isi/h1/burtfiles/h1isiham4_safe.snap controls@h1build scripts 0$ controls@h1build scripts 0$ controls@h1build scripts 0$ controls@h1build scripts 0$ userapps controls@h1build release 0$ ls als aos asc cds ecat etc fmcs guardian hpi ioo isc isi lsc omc pem psl saf sus sys tcs ve controls@h1build release 0$ cd isi controls@h1build isi 0$ ls c1 common h1 h2 l1 m1 s1 x1 x2 controls@h1build isi 0$ cd h1 controls@h1build h1 0$ ls burtfiles daqfiles filterfiles guardian medm models scripts src controls@h1build h1 0$ cd burtfiles/ controls@h1build burtfiles 0$ svn st M h1isiham4_safe.snap controls@h1build burtfiles 0$ svn commit -m "h1isiham4_safe.snap was updated now that IN/Out filters and matrices are installed" h1isiham4_safe.snap Authentication realm: This content is viewable by only LIGO/Virgo personnel. Please enter your LIGO Directory name, e.g. albert.einstein, and password to continue. Password for 'jeffrey.kissel': Authentication realm: This content is viewable by only LIGO/Virgo personnel. Please enter your LIGO Directory name, e.g. albert.einstein, and password to continue. Username: hugo.paris Password for 'hugo.paris': Sending h1isiham4_safe.snap Transmitting file data . Committed revision 7132. controls@opsws1:~ 255$ ssh h1seih45 controls@h1seih45 ~ 0$ controls@h1seih45 ~ 0$ controls@h1seih45 ~ 0$ controls@h1seih45 ~ 0$ controls@h1seih45 ~ 0$ controls@h1seih45 ~ 0$ starth1isiham4 Specified filename iocH1.log does not exist. h1isiham4epics H1 IOC Server started Burt restored /opt/rtcds/lho/h1/target/h1isiham4/h1isiham4epics/burt/safe.snap Old : H1:FEC-61_BURT_RESTORE 1 New : H1:FEC-61_BURT_RESTORE 1 * Starting h1isiham4 awgtpman ... [ !! ] controls@h1seih45 ~ 0$