%1611 photodiode with 20dB amplifier at AS_REFL on ISCT6 %signal read into spectrum analyzer with michelwson locked to the bright fringe. %10kHz resolution bandwidth, 801 points %measurement. Noise floor at -70dBm. %we measured with auxiliary laser offset on one side of the carrier, then %moved to the other side. when measuring side 2 maybe michelson was not %aligned as well because all of the measured values were lower than for %side_1. We are planning to go back and repeat this side. %auxiliary laser offset controlled on H1:LSC_EXTRA_AO_2 about 4V, amplified %by SN560. We needed roughly 4V to see a beat note, and moved around by %0.05 V divisions %beat note from ISCT2R table 1611PD rerouted to ISCT6 on rack feedthroughs %(ISCR2 to ISCR4 or something, with something in the middle?) freq_amp_side1=[ ... 940.38 -54.18 %MHz, dBm 940.56 -53.96 940.75 -54.137 954.6 -55 983.125 -52.651 941.875 -54.7 886.475 -60.7 872.31 -60.11 844.81 -59.3 845 -59 845 -62.4 824.75 -56 803.6 -58.7 803.625 -60 776.25 -58 757.7 -57.9 736.6 -59.0 709.18 -57.4 709.18 -55.5 689.125 -54.6 666.6 -53.2 668.3 -53.5 ]; freq_amp_side2=[ ... 701.625 -57.5 701.4 -58.0 729.6 -59.3 729.75 -59.1 771.9 -63.1 771.9 -64.0 820.938 nan %-69 %beneath -69dBm noise floor 771.3 -64.1 820.18 nan %-69 %beneath -69dBm noise floor 867 nan %-69 %beneath -69dBm noise floor 910.7 -62.74 951.38 -58.38 952.5 -59.2 1000.0 -57.2 ];