# SR785 Measurement # Timestamp: Mar 09 2015 - 19:12:49 # Parameter File: TFSR785carm.yml~ #---------- Measurement Setup ------------ # Start frequency (Hz) = 100000.000000 # Stop frequency (Hz) = 100.000000 # Number of frequency points = 40 # Excitation amplitude (mV) = 3.000000 # Settling cycles = 1 # Integration cycles = 40 #---------- Measurement Parameters ---------- # Measurement Group: "Swept Sine" "Swept Sine" # Measurements: "Frequency Response" "Frequency Response" # View: "Log Magnitude" "Phase" # Unit: "dB" "deg" #---------- Input Parameters ---------- # Input Source: Analog # Input Mode: Single ended, Single ended # Input Grounding: Float, Float # Input Coupling: AC, AC # Input Range: -42.0dBVpk, -40.0dBVpk # Auto Range: On, On # Auto Range Mode: Up Only, Normal # Anti-Aliasing Filter: On, On #---------- Source Parameters ---------- # Source Type: Sine # Source Amplitude: 3.0mVpk # Source On: 0 #---------- Measurement Data ---------- # [Freq(Hz) Display 0(dB) Display 1(deg) ] +1.0000000e+002 +1.0556790e+001 -6.3566574e+001 +1.1937766e+002 +1.4848533e+001 -1.5409198e+002 +1.4251027e+002 +1.2402422e+001 +6.3607197e+001 +1.7012543e+002 +2.9594782e+001 +1.6412396e+002 +2.0309177e+002 +1.8423565e+001 +1.6101326e+002 +2.4244620e+002 +1.1403853e+001 +6.3096424e+001 +2.8942661e+002 +4.8432335e+001 -2.9293417e+001 +3.4551074e+002 +2.4722248e+001 -2.6657141e+001 +4.1246265e+002 +2.0095999e+001 +1.7417235e+002 +4.9238828e+002 +3.3678432e+001 -1.2730423e+002 +5.8780164e+002 +2.8009275e+001 -1.4018124e+002 +7.0170386e+002 +3.6612827e+001 +4.1983799e+001 +8.3767761e+002 +3.1299412e+001 -1.6754947e+002 +1.0000000e+003 +2.0068871e+001 -1.5495049e+002 +1.1937766e+003 +2.3550043e+001 -1.5277016e+002 +1.4251027e+003 +2.1763479e+001 -1.6636888e+002 +1.7012543e+003 +1.8804539e+001 -1.4279866e+002 +2.0309176e+003 +1.6106426e+001 -1.4823831e+002 +2.4244619e+003 +1.3623705e+001 -1.4137485e+002 +2.8942661e+003 +1.0659951e+001 -1.3913316e+002 +3.4551072e+003 +8.7596540e+000 -1.2483033e+002 +4.1246265e+003 +7.5090966e+000 -1.2312007e+002 +4.9238828e+003 +4.3615913e+000 -1.1887639e+002 +5.8780161e+003 +3.1227682e+000 -1.1378124e+002 +7.0170381e+003 +1.7144557e+000 -1.0898312e+002 +8.3767764e+003 +1.4671388e-001 -1.0700032e+002 +1.0000000e+004 -1.0994040e+000 -1.0499971e+002 +1.1937767e+004 -2.2597842e+000 -1.0446867e+002 +1.4251026e+004 -3.4707065e+000 -1.0523978e+002 +1.7012543e+004 -4.5508199e+000 -1.0894786e+002 +2.0309176e+004 -8.2551498e+000 -1.1695821e+002 +2.4244621e+004 -6.9783893e+000 -1.1386043e+002 +2.8942662e+004 -8.1477938e+000 -1.2283839e+002 +3.4551074e+004 -9.9183407e+000 -1.3265060e+002 +4.1246266e+004 -1.1573442e+001 -1.4204926e+002 +4.9238828e+004 -1.3704582e+001 -1.5285417e+002 +5.8780160e+004 -1.5772099e+001 -1.6025642e+002 +7.0170383e+004 -1.7473101e+001 -1.6987753e+002 +8.3767766e+004 -1.8963028e+001 +1.7878712e+002 +1.0000000e+005 -1.8743990e+001 +1.6412646e+002 +1.1937766e+005 +1.0556790e+001 -6.3566574e+001