# TF from MICH_OUT_DQ to OMC-DCPD_SUM_OUT_DQ # Start time 2015-06-14 06:10:25 # 200 avg, 50% overlap # Frequency [Hz] Real part [mA/ct] Imag part [mA/ct] Coherence [] 1.050000000000000000e+01 9.845734900000000417e-06 -6.004002400000000011e-05 2.222472400000000126e-02 1.100000000000000000e+01 1.083673200000000082e-06 -4.451072999999999930e-06 1.827020899999999928e-04 1.150000000000000000e+01 -1.324810499999999977e-05 2.674152700000000107e-06 2.005351900000000142e-03 1.200000000000000000e+01 -1.123919200000000052e-05 4.301645500000000080e-05 2.085546599999999959e-02 1.250000000000000000e+01 4.557869499999999916e-06 9.038824800000000778e-06 7.619531199999999551e-04 1.300000000000000000e+01 1.208991500000000027e-05 5.920776700000000229e-05 1.807928500000000049e-02 1.350000000000000000e+01 -4.843538100000000016e-06 -5.860988700000000049e-05 1.486722799999999969e-02 1.400000000000000000e+01 8.896794300000000343e-05 7.729325399999999483e-05 3.476882399999999679e-02 1.450000000000000000e+01 2.863530599999999983e-05 -8.069867200000000384e-05 5.717555800000000132e-02 1.500000000000000000e+01 -2.205722399999999846e-05 -5.581642499999999813e-05 4.594273499999999844e-02 1.550000000000000000e+01 -3.149233100000000150e-05 -2.587406699999999989e-05 3.569177199999999661e-02 1.600000000000000000e+01 -1.839102200000000079e-05 -1.766124899999999975e-07 6.296582499999999957e-03 1.650000000000000000e+01 -1.145861599999999946e-05 1.832642200000000144e-05 7.796357900000000160e-03 1.700000000000000000e+01 -2.634548800000000094e-05 -3.285455300000000196e-06 1.823346299999999837e-02 1.750000000000000000e+01 1.400510300000000068e-06 -8.303508399999999675e-05 1.301407699999999890e-01 1.800000000000000000e+01 9.020834099999999365e-05 -4.236188799999999891e-05 1.083770800000000006e-01 1.850000000000000000e+01 1.312359699999999998e-04 1.034284899999999934e-04 5.601934800000000214e-01 1.900000000000000000e+01 1.217071500000000024e-04 8.056821400000000388e-05 7.658757600000000165e-01 1.950000000000000000e+01 1.182924100000000000e-04 5.044520700000000194e-05 8.229191300000000542e-01 2.000000000000000000e+01 1.104386899999999962e-04 3.719492800000000188e-05 8.565409800000000073e-01 2.050000000000000000e+01 1.099141300000000006e-04 2.059370099999999841e-05 8.941564600000000418e-01 2.100000000000000000e+01 1.077591400000000059e-04 7.001743599999999998e-06 9.324487399999999981e-01 2.150000000000000000e+01 1.023013699999999939e-04 -1.121234900000000008e-05 9.409350800000000348e-01 2.200000000000000000e+01 9.320136499999999598e-05 -2.796776600000000046e-05 9.587323100000000320e-01 2.250000000000000000e+01 8.158838300000000661e-05 -4.636870700000000125e-05 9.642400100000000362e-01 2.300000000000000000e+01 6.577611200000000149e-05 -6.244544800000000149e-05 9.641785000000000494e-01 2.350000000000000000e+01 4.028291000000000087e-05 -8.142137799999999922e-05 9.448981300000000028e-01 2.400000000000000000e+01 2.663290600000000186e-06 -1.041403700000000012e-04 9.104722699999999724e-01 2.450000000000000000e+01 -7.125872099999999330e-05 -1.273401900000000104e-04 8.174319300000000288e-01 2.500000000000000000e+01 -1.978267099999999950e-04 -1.065766299999999940e-04 6.856447500000000250e-01 2.550000000000000000e+01 -2.387424999999999931e-04 9.987246399999999782e-05 4.802654399999999879e-01 2.600000000000000000e+01 -2.466333199999999902e-05 2.604233700000000091e-04 7.519008499999999540e-01 2.650000000000000000e+01 1.651562899999999955e-04 2.581868299999999744e-04 5.296097400000000510e-01 2.700000000000000000e+01 3.099711599999999882e-04 4.031611399999999670e-05 7.729512499999999786e-01 2.750000000000000000e+01 2.215471600000000095e-04 -6.088504600000000321e-05 9.180768700000000448e-01 2.800000000000000000e+01 1.490459699999999936e-04 -7.894573400000000514e-05 9.671747099999999930e-01 2.850000000000000000e+01 1.123531699999999982e-04 -8.214686399999999934e-05 9.831322399999999906e-01 2.900000000000000000e+01 8.398768099999999687e-05 -8.139717800000000037e-05 9.871654499999999999e-01 2.950000000000000000e+01 6.553842100000000675e-05 -8.068155899999999796e-05 9.915078299999999789e-01 3.000000000000000000e+01 5.193815399999999766e-05 -7.839636999999999832e-05 9.935841600000000495e-01 3.050000000000000000e+01 3.922736899999999837e-05 -7.517734799999999389e-05 9.934603600000000423e-01 3.100000000000000000e+01 2.957967300000000020e-05 -7.264737399999999384e-05 9.940485999999999489e-01 3.150000000000000000e+01 2.047839199999999839e-05 -6.897551100000000063e-05 9.936209900000000372e-01 3.200000000000000000e+01 1.311007799999999988e-05 -6.551338400000000491e-05 9.945941600000000049e-01 3.250000000000000000e+01 6.162942600000000268e-06 -6.175587600000000382e-05 9.938707399999999748e-01 3.300000000000000000e+01 1.063914899999999936e-07 -5.737263200000000110e-05 9.937099799999999927e-01 3.350000000000000000e+01 -4.642645800000000360e-06 -5.331261900000000044e-05 9.943118100000000181e-01 3.400000000000000000e+01 -8.510106499999999495e-06 -4.913717600000000213e-05 9.817050699999999575e-01 3.450000000000000000e+01 -1.466111399999999923e-05 -4.639273200000000141e-05 8.410909199999999641e-01 3.500000000000000000e+01 -1.707049000000000129e-05 -4.132878500000000210e-05 8.484329600000000138e-01 3.550000000000000000e+01 -1.743636899999999982e-05 -3.586377699999999746e-05 9.884376499999999455e-01 3.600000000000000000e+01 -1.856713400000000017e-05 -3.196125900000000298e-05 9.923868200000000028e-01 3.650000000000000000e+01 -2.004576700000000014e-05 -2.787064099999999925e-05 9.921703899999999576e-01 3.700000000000000000e+01 -2.093670099999999835e-05 -2.432963299999999854e-05 9.938010600000000139e-01 3.750000000000000000e+01 -2.140780999999999926e-05 -2.063899599999999913e-05 9.917486300000000199e-01 3.800000000000000000e+01 -2.132628799999999994e-05 -1.743382899999999832e-05 9.929404899999999534e-01 3.850000000000000000e+01 -2.100329800000000051e-05 -1.438857600000000079e-05 9.913442099999999479e-01 3.900000000000000000e+01 -2.022986000000000150e-05 -1.133292199999999971e-05 9.905387799999999521e-01 3.950000000000000000e+01 -1.964273400000000051e-05 -8.642745300000000702e-06 9.906231800000000476e-01 4.000000000000000000e+01 -1.861968300000000080e-05 -6.359377499999999745e-06 9.902164300000000363e-01 4.050000000000000000e+01 -1.723886099999999853e-05 -4.103833800000000207e-06 9.686459299999999883e-01 4.100000000000000000e+01 -1.606392999999999919e-05 -2.178261199999999825e-06 9.252104799999999463e-01 4.150000000000000000e+01 -1.475011999999999931e-05 -8.243247300000000178e-07 9.726789000000000129e-01 4.200000000000000000e+01 -1.346833599999999959e-05 4.697743899999999937e-07 9.869463400000000330e-01 4.250000000000000000e+01 -1.209719700000000011e-05 1.525256800000000026e-06 9.841378899999999597e-01 4.300000000000000000e+01 -1.055024099999999988e-05 2.231532800000000123e-06 9.835380900000000315e-01 4.350000000000000000e+01 -9.256926200000000431e-06 2.805051700000000173e-06 9.799918499999999977e-01 4.400000000000000000e+01 -8.075891899999999886e-06 3.330387499999999884e-06 9.819056999999999924e-01 4.450000000000000000e+01 -6.906859200000000118e-06 3.610497100000000059e-06 9.783350800000000236e-01 4.500000000000000000e+01 -5.826141200000000379e-06 3.795046000000000087e-06 9.758297200000000116e-01 4.550000000000000000e+01 -4.713137100000000144e-06 3.836406900000000276e-06 9.705252100000000270e-01 4.600000000000000000e+01 -3.830516600000000079e-06 3.890469100000000417e-06 9.672338999999999798e-01 4.650000000000000000e+01 -2.999892299999999877e-06 3.707338699999999840e-06 9.611165499999999584e-01 4.700000000000000000e+01 -2.207844300000000036e-06 3.445580899999999844e-06 9.647495200000000271e-01 4.750000000000000000e+01 -1.503886999999999972e-06 3.188353500000000135e-06 9.509472300000000322e-01 4.800000000000000000e+01 -9.247927400000000508e-07 2.905244399999999855e-06 9.426644400000000479e-01 4.850000000000000000e+01 -4.492093200000000053e-07 2.631165199999999868e-06 9.291406300000000229e-01 4.900000000000000000e+01 -2.859720999999999869e-08 2.293397099999999998e-06 9.297598000000000251e-01 4.950000000000000000e+01 3.694081799999999861e-07 1.981676200000000080e-06 9.120642500000000208e-01 5.000000000000000000e+01 6.424600699999999863e-07 1.584602000000000096e-06 9.066947699999999832e-01 5.050000000000000000e+01 8.619298299999999553e-07 1.313162300000000019e-06 9.145001200000000274e-01 5.100000000000000000e+01 9.921648100000000427e-07 9.992129400000000358e-07 8.949622499999999592e-01 5.150000000000000000e+01 1.095087999999999992e-06 5.765576800000000240e-07 8.646745099999999518e-01 5.200000000000000000e+01 1.181065000000000101e-06 2.698000999999999861e-07 8.789040399999999975e-01 5.250000000000000000e+01 1.256543899999999960e-06 1.937498200000000066e-08 8.936039199999999960e-01 5.300000000000000000e+01 1.258377400000000067e-06 -2.103555900000000027e-07 9.090406300000000162e-01 5.350000000000000000e+01 1.272154800000000014e-06 -4.457426700000000170e-07 9.355211900000000025e-01 5.400000000000000000e+01 1.235253000000000030e-06 -5.932879500000000157e-07 9.470779299999999568e-01 5.450000000000000000e+01 1.173760099999999989e-06 -7.466495599999999712e-07 9.472160299999999866e-01 5.500000000000000000e+01 1.053443800000000009e-06 -9.408298599999999567e-07 9.426282000000000272e-01 5.550000000000000000e+01 9.511902600000000261e-07 -1.092745400000000083e-06 9.521726999999999830e-01 5.600000000000000000e+01 8.527963999999999772e-07 -1.207622400000000034e-06 9.584456700000000273e-01 5.650000000000000000e+01 7.382595300000000367e-07 -1.303388600000000030e-06 9.691312300000000102e-01 5.700000000000000000e+01 6.614276899999999990e-07 -1.370908899999999965e-06 9.744920700000000435e-01 5.750000000000000000e+01 5.448983399999999760e-07 -1.433690199999999953e-06 9.752392199999999622e-01 5.800000000000000000e+01 4.375575599999999984e-07 -1.455369800000000004e-06 9.742115099999999472e-01 5.850000000000000000e+01 3.096376699999999772e-07 -1.475371699999999929e-06 9.756767200000000528e-01 5.900000000000000000e+01 2.513733900000000221e-07 -1.487239399999999910e-06 9.790383000000000280e-01 5.950000000000000000e+01 1.306874399999999922e-07 -1.518693500000000099e-06 4.280872900000000092e-01 6.000000000000000000e+01 -2.199360700000000073e-07 -1.630877500000000040e-06 1.910520199999999891e-01 6.050000000000000000e+01 -9.105360700000000635e-08 -1.497362199999999943e-06 4.717304700000000128e-01 6.100000000000000000e+01 -1.229188500000000022e-07 -1.459576999999999968e-06 9.842419000000000029e-01 6.150000000000000000e+01 -1.906036300000000117e-07 -1.410355699999999897e-06 9.846977599999999775e-01 6.200000000000000000e+01 -2.619607099999999793e-07 -1.368108000000000090e-06 9.837214399999999470e-01 6.250000000000000000e+01 -3.225728699999999910e-07 -1.315835800000000020e-06 9.841166099999999473e-01 6.300000000000000000e+01 -3.656203899999999995e-07 -1.270130299999999929e-06 9.866091599999999850e-01 6.350000000000000000e+01 -4.052601000000000093e-07 -1.215309100000000012e-06 9.869278099999999609e-01 6.400000000000000000e+01 -4.418515399999999774e-07 -1.171997999999999904e-06 9.842859499999999651e-01 6.450000000000000000e+01 -4.932239799999999506e-07 -1.105921799999999958e-06 9.810601500000000197e-01 6.500000000000000000e+01 -5.147892399999999622e-07 -1.042556799999999972e-06 9.817491200000000307e-01 6.550000000000000000e+01 -5.355845499999999703e-07 -9.810209999999999540e-07 9.824459599999999515e-01 6.600000000000000000e+01 -5.630140000000000148e-07 -9.276144500000000282e-07 9.831959599999999799e-01 6.650000000000000000e+01 -5.769294899999999683e-07 -8.776379399999999547e-07 9.831852899999999895e-01 6.700000000000000000e+01 -5.879216999999999593e-07 -8.085195899999999848e-07 9.834093499999999599e-01 6.750000000000000000e+01 -5.865606500000000081e-07 -7.667559300000000244e-07 9.833326300000000408e-01 6.800000000000000000e+01 -6.043596299999999747e-07 -7.320849100000000512e-07 9.842602000000000295e-01 6.850000000000000000e+01 -6.064755700000000388e-07 -6.800519299999999649e-07 9.815748899999999777e-01 6.900000000000000000e+01 -5.977558400000000243e-07 -6.359582000000000202e-07 9.803628899999999868e-01 6.950000000000000000e+01 -5.867024099999999867e-07 -5.846594599999999955e-07 9.789417999999999731e-01 7.000000000000000000e+01 -5.922411200000000010e-07 -5.245981399999999488e-07 9.786568900000000015e-01 7.050000000000000000e+01 -5.780806899999999608e-07 -4.836295499999999527e-07 9.774312400000000345e-01 7.100000000000000000e+01 -5.622726999999999656e-07 -4.509428500000000019e-07 9.789774399999999765e-01 7.150000000000000000e+01 -5.477049899999999570e-07 -4.170586000000000073e-07 9.771655200000000097e-01 7.200000000000000000e+01 -5.400879700000000089e-07 -3.888250699999999786e-07 9.768854999999999622e-01 7.250000000000000000e+01 -5.217575000000000185e-07 -3.591227399999999890e-07 9.699737999999999971e-01 7.300000000000000000e+01 -5.081938099999999503e-07 -3.202552299999999920e-07 9.705549500000000274e-01 7.350000000000000000e+01 -4.943855199999999701e-07 -2.966335199999999871e-07 9.701228699999999705e-01 7.400000000000000000e+01 -4.818370500000000245e-07 -2.711206799999999869e-07 9.629285899999999732e-01 7.450000000000000000e+01 -4.667084600000000003e-07 -2.308873400000000106e-07 9.462037699999999996e-01 7.500000000000000000e+01 -4.328801100000000242e-07 -2.137133199999999988e-07 7.628390200000000343e-01 7.550000000000000000e+01 -4.187050399999999759e-07 -2.007617800000000040e-07 6.925309899999999574e-01 7.600000000000000000e+01 -4.049645399999999992e-07 -1.759895299999999921e-07 9.283694599999999797e-01 7.650000000000000000e+01 -3.777154199999999794e-07 -1.498850499999999912e-07 9.420681600000000433e-01 7.700000000000000000e+01 -3.604944500000000163e-07 -1.259661100000000064e-07 9.375118599999999747e-01 7.750000000000000000e+01 -3.432609200000000199e-07 -1.164516100000000042e-07 9.410896300000000103e-01 7.800000000000000000e+01 -3.311678500000000030e-07 -1.107068099999999990e-07 9.350823200000000224e-01 7.850000000000000000e+01 -3.167634200000000038e-07 -9.609546899999999520e-08 9.235628799999999750e-01 7.900000000000000000e+01 -2.923309200000000264e-07 -7.517917300000000657e-08 9.100651699999999789e-01 7.950000000000000000e+01 -2.749664500000000197e-07 -6.515700300000000333e-08 9.042460900000000024e-01 8.000000000000000000e+01 -2.619062499999999965e-07 -5.695140400000000129e-08 8.958607899999999624e-01 8.050000000000000000e+01 -2.392043000000000054e-07 -5.269234999999999868e-08 8.837363099999999694e-01 8.100000000000000000e+01 -2.209768199999999897e-07 -4.698099699999999800e-08 8.692249699999999857e-01 8.150000000000000000e+01 -2.139492200000000095e-07 -4.299562000000000129e-08 8.503820300000000110e-01 8.200000000000000000e+01 -1.907921900000000064e-07 -2.836192300000000138e-08 7.643915399999999805e-01 8.250000000000000000e+01 -1.800422100000000125e-07 -3.064668200000000094e-08 6.608719800000000255e-01 8.300000000000000000e+01 -1.765108100000000104e-07 -3.317045500000000134e-08 7.316386099999999670e-01 8.350000000000000000e+01 -1.577946400000000088e-07 -2.649699700000000132e-08 7.990063400000000371e-01 8.400000000000000000e+01 -1.406828000000000056e-07 -1.957864799999999978e-08 8.044744700000000526e-01 8.450000000000000000e+01 -1.292802099999999977e-07 -1.818101899999999859e-08 7.576723100000000155e-01 8.500000000000000000e+01 -1.212029200000000044e-07 -1.520742500000000159e-08 7.028877100000000544e-01 8.550000000000000000e+01 -1.045687899999999941e-07 -1.868116199999999902e-08 6.442023500000000347e-01 8.600000000000000000e+01 -9.131206699999999555e-08 -1.254386100000000005e-08 6.164779700000000418e-01 8.650000000000000000e+01 -8.381034200000000386e-08 -8.336243699999999268e-09 5.639246700000000168e-01 8.700000000000000000e+01 -7.096581100000000426e-08 -6.468693599999999827e-09 4.594307200000000146e-01 8.750000000000000000e+01 -6.109507200000000192e-08 -9.349057500000000004e-09 3.865413699999999952e-01 8.800000000000000000e+01 -5.597478699999999823e-08 -8.946367200000000754e-09 3.525945799999999908e-01 8.850000000000000000e+01 -5.153630799999999797e-08 -6.968766900000000373e-09 3.451504400000000028e-01 8.900000000000000000e+01 -4.292646899999999734e-08 -1.150775699999999984e-08 2.907578599999999791e-01 8.950000000000000000e+01 -3.141258599999999850e-08 -8.253156399999999746e-09 1.608949600000000035e-01 9.000000000000000000e+01 -2.615414700000000100e-08 -1.068146599999999948e-08 1.420843499999999981e-01 9.050000000000000000e+01 -1.467364599999999923e-08 -1.727133999999999880e-08 9.934309900000000415e-02 9.100000000000000000e+01 -3.511997799999999992e-09 -1.922961899999999846e-08 7.156266299999999858e-02 9.150000000000000000e+01 -3.411226899999999856e-09 -1.695767799999999865e-08 6.068133900000000081e-02 9.200000000000000000e+01 5.808280099999999748e-09 -1.638769700000000026e-08 5.455637399999999776e-02 9.250000000000000000e+01 1.625268300000000154e-08 -2.453136500000000031e-08 1.616976900000000050e-01 9.300000000000000000e+01 2.547431999999999977e-08 -2.830539200000000023e-08 2.212668499999999872e-01 9.350000000000000000e+01 2.851327500000000026e-08 -2.462404299999999981e-08 2.271977199999999919e-01 9.400000000000000000e+01 3.632208500000000320e-08 -2.513279200000000066e-08 3.080732800000000049e-01 9.450000000000000000e+01 4.205275400000000043e-08 -2.936198299999999969e-08 3.756302000000000252e-01 9.500000000000000000e+01 4.615696999999999803e-08 -3.426803000000000248e-08 4.267725299999999833e-01 9.550000000000000000e+01 5.458872799999999931e-08 -3.485184799999999787e-08 4.903650299999999795e-01 9.600000000000000000e+01 5.632539099999999869e-08 -3.787683400000000230e-08 5.040388099999999483e-01 9.650000000000000000e+01 6.035059400000000514e-08 -3.810476600000000093e-08 5.735464099999999510e-01 9.700000000000000000e+01 6.299502799999999829e-08 -4.328075999999999851e-08 6.034775999999999474e-01 9.750000000000000000e+01 7.774120499999999696e-08 -5.103078800000000073e-08 6.774315800000000332e-01 9.800000000000000000e+01 8.419385000000000452e-08 -5.794141000000000082e-08 7.157971899999999721e-01 9.850000000000000000e+01 8.767105400000000201e-08 -6.480579600000000586e-08 7.528458199999999989e-01 9.900000000000000000e+01 8.993819699999999438e-08 -7.169268200000000333e-08 7.667462200000000339e-01 9.950000000000000000e+01 8.944439100000000561e-08 -7.913535400000000056e-08 7.679225200000000529e-01 1.000000000000000000e+02 9.266700799999999450e-08 -8.709869099999999539e-08 7.986090799999999712e-01 1.005000000000000000e+02 9.483925800000000259e-08 -9.623075700000000186e-08 8.537358600000000131e-01 1.010000000000000000e+02 9.066894100000000051e-08 -9.878272799999999786e-08 8.523782500000000040e-01 1.015000000000000000e+02 8.514923899999999711e-08 -1.051933799999999964e-07 8.457870499999999847e-01 1.020000000000000000e+02 8.152488800000000113e-08 -1.123646000000000055e-07 8.513979900000000489e-01 1.025000000000000000e+02 7.849485000000000093e-08 -1.113029500000000047e-07 8.478991399999999956e-01 1.030000000000000000e+02 7.525163400000000025e-08 -1.182058399999999951e-07 8.658604600000000540e-01 1.035000000000000000e+02 7.383342599999999364e-08 -1.230818199999999988e-07 8.744865699999999631e-01 1.040000000000000000e+02 7.190671199999999748e-08 -1.259799499999999978e-07 8.774359800000000043e-01 1.045000000000000000e+02 6.855510299999999721e-08 -1.278772299999999881e-07 8.898698099999999833e-01 1.050000000000000000e+02 6.585760600000000660e-08 -1.322286500000000132e-07 8.954935699999999610e-01 1.055000000000000000e+02 6.143000100000000511e-08 -1.285518500000000104e-07 8.875030900000000500e-01 1.060000000000000000e+02 5.907621099999999685e-08 -1.303667400000000018e-07 8.883910200000000312e-01 1.065000000000000000e+02 5.910133899999999982e-08 -1.369240700000000048e-07 9.164289799999999486e-01 1.070000000000000000e+02 5.771152099999999709e-08 -1.349333399999999972e-07 9.074736799999999493e-01 1.075000000000000000e+02 5.488954700000000168e-08 -1.385409999999999963e-07 8.897811199999999809e-01 1.080000000000000000e+02 5.056270800000000042e-08 -1.384232199999999988e-07 8.837447200000000391e-01 1.085000000000000000e+02 4.866698000000000186e-08 -1.392559900000000031e-07 8.986874200000000146e-01 1.090000000000000000e+02 4.807927199999999730e-08 -1.426281700000000063e-07 9.023830900000000543e-01 1.095000000000000000e+02 4.553028499999999959e-08 -1.448740800000000031e-07 9.051703199999999727e-01 1.100000000000000000e+02 4.544892800000000239e-08 -1.518565799999999930e-07 9.018576099999999762e-01 1.105000000000000000e+02 4.406702899999999945e-08 -1.538525300000000103e-07 9.144175599999999626e-01 1.110000000000000000e+02 3.952539300000000109e-08 -1.517576899999999886e-07 9.181070900000000146e-01 1.115000000000000000e+02 3.197430599999999726e-08 -1.476189800000000001e-07 9.049431700000000189e-01 1.120000000000000000e+02 3.252962300000000303e-08 -1.504871800000000072e-07 9.106432800000000549e-01 1.125000000000000000e+02 3.482608000000000264e-08 -1.537525799999999989e-07 9.162996399999999708e-01 1.130000000000000000e+02 3.019365400000000113e-08 -1.490359700000000089e-07 9.114086000000000132e-01 1.135000000000000000e+02 2.845284199999999934e-08 -1.510555399999999984e-07 9.158544499999999866e-01 1.140000000000000000e+02 2.479910000000000135e-08 -1.530574599999999931e-07 9.226074199999999559e-01 1.145000000000000000e+02 2.240281000000000114e-08 -1.516993400000000032e-07 9.175072300000000070e-01 1.150000000000000000e+02 1.880669099999999837e-08 -1.518281200000000132e-07 9.236846600000000462e-01 1.155000000000000000e+02 1.452074399999999925e-08 -1.509971500000000003e-07 9.138016700000000103e-01 1.160000000000000000e+02 1.358376400000000028e-08 -1.502540200000000097e-07 8.618996700000000066e-01 1.165000000000000000e+02 1.781195099999999856e-08 -1.498843300000000000e-07 8.425111199999999467e-01 1.170000000000000000e+02 1.171926300000000004e-08 -1.557988400000000062e-07 8.866872199999999982e-01 1.175000000000000000e+02 -1.589730800000000100e-09 -1.594817700000000110e-07 9.057731599999999661e-01 1.180000000000000000e+02 -1.643384999999999862e-08 -1.553485699999999989e-07 8.656220399999999815e-01 1.185000000000000000e+02 -9.904299600000000092e-09 -1.428531500000000036e-07 7.910944199999999649e-01 1.190000000000000000e+02 1.800894100000000038e-09 -1.385334699999999981e-07 8.229716400000000043e-01 1.195000000000000000e+02 -8.078920899999999929e-10 -1.476060899999999874e-07 7.247936099999999771e-01 1.200000000000000000e+02 -8.709065499999999801e-09 -1.547404299999999927e-07 5.658693900000000276e-01 1.205000000000000000e+02 -2.857061500000000123e-09 -1.542997799999999947e-07 7.895986999999999867e-01 1.210000000000000000e+02 -4.585662100000000321e-09 -1.573564400000000043e-07 9.171908500000000020e-01 1.215000000000000000e+02 -7.761014100000000338e-09 -1.588145400000000086e-07 9.356700199999999912e-01 1.220000000000000000e+02 -8.820622500000000474e-09 -1.614037900000000130e-07 9.257745099999999949e-01 1.225000000000000000e+02 -1.559118499999999986e-08 -1.608032999999999904e-07 9.161099799999999904e-01 1.230000000000000000e+02 -1.987283799999999998e-08 -1.526276899999999957e-07 9.278956699999999502e-01 1.235000000000000000e+02 -2.317531899999999984e-08 -1.543874599999999925e-07 9.193590900000000454e-01 1.240000000000000000e+02 -2.661260200000000033e-08 -1.581282000000000090e-07 9.074957999999999636e-01 1.245000000000000000e+02 -2.872908699999999997e-08 -1.587173300000000103e-07 8.945826900000000137e-01 1.250000000000000000e+02 -3.405018799999999756e-08 -1.589745299999999949e-07 8.450688100000000036e-01 1.255000000000000000e+02 -4.573772499999999738e-08 -1.490705599999999907e-07 6.158581400000000539e-01 1.260000000000000000e+02 -3.997520900000000272e-08 -1.237081900000000126e-07 4.595309499999999936e-01 1.265000000000000000e+02 -2.989433799999999810e-08 -1.350651400000000037e-07 6.929803500000000227e-01 1.270000000000000000e+02 -2.931653999999999935e-08 -1.458222000000000046e-07 8.472625000000000295e-01 1.275000000000000000e+02 -2.775899499999999902e-08 -1.466249800000000112e-07 8.788405700000000431e-01 1.280000000000000000e+02 -3.106492499999999982e-08 -1.491258499999999933e-07 9.002652199999999771e-01 1.285000000000000000e+02 -3.912421999999999748e-08 -1.509644700000000119e-07 9.158955800000000425e-01 1.290000000000000000e+02 -3.792056100000000156e-08 -1.476708500000000110e-07 9.053423400000000232e-01 1.295000000000000000e+02 -2.836572399999999873e-08 -1.459639900000000126e-07 9.057005599999999879e-01 1.300000000000000000e+02 -2.917497700000000080e-08 -1.472818400000000101e-07 9.042855499999999935e-01 1.305000000000000000e+02 -2.544307200000000137e-08 -1.518510800000000000e-07 8.785371800000000286e-01 1.310000000000000000e+02 -2.375680099999999835e-08 -1.724977099999999941e-07 8.249355000000000437e-01 1.315000000000000000e+02 -6.634787299999999551e-08 -2.018210400000000039e-07 8.318850399999999645e-01 1.320000000000000000e+02 -8.166586000000000651e-08 -1.665451399999999918e-07 8.096587100000000037e-01 1.325000000000000000e+02 -4.102559400000000250e-08 -1.720364899999999968e-07 6.687024200000000196e-01 1.330000000000000000e+02 -8.545029600000000256e-08 -2.007954299999999905e-07 6.807531100000000501e-01 1.335000000000000000e+02 -1.209130100000000020e-07 -1.656291699999999884e-07 7.951082600000000111e-01 1.340000000000000000e+02 -1.135299900000000016e-07 -1.461053499999999961e-07 8.853800899999999530e-01 1.345000000000000000e+02 -1.084863700000000016e-07 -1.395532899999999988e-07 9.158768099999999857e-01 1.350000000000000000e+02 -1.048495599999999946e-07 -1.329582100000000125e-07 9.175093199999999616e-01 1.355000000000000000e+02 -1.055814100000000026e-07 -1.308881799999999917e-07 9.216948200000000258e-01 1.360000000000000000e+02 -1.045802700000000008e-07 -1.287431400000000084e-07 9.147105199999999714e-01 1.365000000000000000e+02 -1.045802200000000047e-07 -1.283382000000000050e-07 9.228759399999999502e-01 1.370000000000000000e+02 -1.067853700000000051e-07 -1.251854200000000071e-07 9.264655699999999605e-01 1.375000000000000000e+02 -1.025573899999999951e-07 -1.238979299999999996e-07 9.246060299999999677e-01 1.380000000000000000e+02 -1.052434900000000021e-07 -1.233995400000000054e-07 9.280030099999999615e-01 1.385000000000000000e+02 -1.063757399999999956e-07 -1.181887799999999964e-07 9.239063899999999663e-01 1.390000000000000000e+02 -1.048632700000000041e-07 -1.169079799999999973e-07 9.015044599999999519e-01 1.395000000000000000e+02 -1.116249400000000027e-07 -1.205512299999999926e-07 8.872394599999999798e-01 1.400000000000000000e+02 -1.150374500000000042e-07 -1.132834400000000039e-07 8.925748500000000307e-01 1.405000000000000000e+02 -1.118387299999999997e-07 -1.059829899999999937e-07 8.712329300000000165e-01 1.410000000000000000e+02 -1.100017400000000044e-07 -1.084389000000000036e-07 8.530044599999999644e-01 1.415000000000000000e+02 -1.003937700000000050e-07 -1.095001300000000029e-07 8.414996900000000224e-01 1.420000000000000000e+02 -1.054795899999999972e-07 -1.083218600000000038e-07 8.063631100000000496e-01 1.425000000000000000e+02 -9.585318799999999848e-08 -1.013607499999999966e-07 7.137436299999999623e-01 1.430000000000000000e+02 -5.472492099999999998e-08 -1.130582599999999958e-07 4.594964999999999744e-01 1.435000000000000000e+02 -8.719149499999999867e-08 -1.760236799999999924e-07 6.160429099999999991e-01 1.440000000000000000e+02 -1.539568499999999920e-07 -1.581586399999999980e-07 8.287406000000000494e-01 1.445000000000000000e+02 -1.511632799999999983e-07 -1.278446900000000047e-07 8.673579700000000337e-01 1.450000000000000000e+02 -1.570161600000000059e-07 -1.178112000000000061e-07 8.954917199999999911e-01 1.455000000000000000e+02 -1.587758899999999899e-07 -1.094577600000000027e-07 9.133827100000000421e-01 1.460000000000000000e+02 -1.578398399999999912e-07 -9.817034699999999970e-08 9.187843799999999561e-01 1.465000000000000000e+02 -1.552230200000000061e-07 -9.521232199999999595e-08 9.201108199999999959e-01 1.470000000000000000e+02 -1.550923799999999987e-07 -9.011058199999999781e-08 9.154454499999999939e-01 1.475000000000000000e+02 -1.572945499999999889e-07 -9.277350399999999487e-08 9.026697900000000274e-01 1.480000000000000000e+02 -1.630103399999999911e-07 -9.007047200000000342e-08 8.919432800000000050e-01 1.485000000000000000e+02 -1.699773700000000061e-07 -8.331551999999999562e-08 9.265438900000000366e-01 1.490000000000000000e+02 -1.665925600000000069e-07 -8.116257500000000373e-08 9.301655899999999866e-01 1.495000000000000000e+02 -1.737417700000000077e-07 -7.677900299999999979e-08 9.373562899999999809e-01 1.500000000000000000e+02 -1.806698899999999873e-07 -7.162530100000000112e-08 9.300573500000000049e-01 1.505000000000000000e+02 -1.837426099999999944e-07 -6.323299600000000650e-08 8.889087399999999750e-01 1.510000000000000000e+02 -1.855509699999999888e-07 -6.175012099999999594e-08 8.894636000000000209e-01 1.515000000000000000e+02 -1.899471900000000011e-07 -5.081382100000000011e-08 8.579741100000000120e-01 1.520000000000000000e+02 -2.085066500000000031e-07 -1.878819799999999948e-08 6.995322699999999561e-01 1.525000000000000000e+02 -1.731147400000000085e-07 6.414868599999999964e-10 3.983844799999999853e-01 1.530000000000000000e+02 -1.401424300000000098e-07 -3.712217400000000234e-08 2.138464700000000107e-01 1.535000000000000000e+02 -1.137703799999999944e-07 -8.675729499999999204e-09 7.899597999999999343e-02 1.540000000000000000e+02 -8.955667099999999687e-08 -2.511279000000000050e-08 1.856433999999999862e-01 1.545000000000000000e+02 -1.327972500000000015e-07 -4.694573999999999882e-08 8.504757299999999853e-01 1.550000000000000000e+02 -1.478001399999999917e-07 -4.454864599999999708e-08 8.753727700000000223e-01 1.555000000000000000e+02 -1.605417899999999885e-07 -4.324799700000000025e-08 9.059072700000000422e-01 1.560000000000000000e+02 -1.591111200000000129e-07 -4.365355399999999845e-08 9.295434399999999986e-01 1.565000000000000000e+02 -1.628702200000000059e-07 -3.799350500000000031e-08 9.285197299999999876e-01 1.570000000000000000e+02 -1.683816500000000061e-07 -3.511735999999999835e-08 9.385606100000000174e-01 1.575000000000000000e+02 -1.727723300000000127e-07 -3.191184199999999743e-08 9.426926399999999706e-01 1.580000000000000000e+02 -1.726500999999999930e-07 -3.479148699999999674e-08 9.435341400000000212e-01 1.585000000000000000e+02 -1.752215700000000075e-07 -3.160595000000000251e-08 9.421735399999999760e-01 1.590000000000000000e+02 -1.757277199999999872e-07 -2.494911300000000022e-08 9.491117599999999710e-01 1.595000000000000000e+02 -1.745601799999999873e-07 -2.327789500000000133e-08 9.535433700000000012e-01 1.600000000000000000e+02 -1.764658300000000054e-07 -1.699592100000000008e-08 9.432718199999999831e-01 1.605000000000000000e+02 -1.805211699999999870e-07 -1.295194100000000016e-08 9.434801900000000519e-01 1.610000000000000000e+02 -1.837654100000000097e-07 -9.639091300000000471e-09 9.328473800000000038e-01 1.615000000000000000e+02 -1.855453200000000075e-07 -5.621170600000000127e-09 9.382763499999999812e-01 1.620000000000000000e+02 -1.866288700000000014e-07 -6.430079600000000068e-09 9.146391200000000277e-01 1.625000000000000000e+02 -1.847189399999999953e-07 -4.644454200000000122e-09 9.202989299999999595e-01 1.630000000000000000e+02 -1.843254199999999927e-07 -3.024993999999999946e-09 9.339165099999999775e-01 1.635000000000000000e+02 -1.884063199999999959e-07 4.296371900000000215e-10 9.496582199999999974e-01 1.640000000000000000e+02 -1.905606800000000120e-07 8.589815100000000111e-09 9.373180300000000242e-01 1.645000000000000000e+02 -1.888204400000000007e-07 1.501850899999999934e-08 9.419174799999999736e-01 1.650000000000000000e+02 -1.893956899999999978e-07 1.953026400000000162e-08 9.471779500000000462e-01 1.655000000000000000e+02 -1.936354199999999881e-07 2.113013799999999894e-08 9.455516899999999447e-01 1.660000000000000000e+02 -1.902713199999999931e-07 2.151386800000000088e-08 9.434296500000000085e-01 1.665000000000000000e+02 -1.860486500000000015e-07 2.409797199999999947e-08 9.473159899999999967e-01 1.670000000000000000e+02 -1.874595199999999917e-07 3.021824900000000294e-08 9.574931899999999940e-01 1.675000000000000000e+02 -1.845902300000000011e-07 3.229923700000000299e-08 9.559938300000000444e-01 1.680000000000000000e+02 -1.836065999999999892e-07 3.668534300000000075e-08 9.544911400000000157e-01 1.685000000000000000e+02 -1.865474099999999879e-07 3.683005900000000185e-08 9.271993600000000280e-01 1.690000000000000000e+02 -1.906559799999999904e-07 4.050605900000000115e-08 9.385610800000000475e-01 1.695000000000000000e+02 -1.932635599999999947e-07 4.468743600000000173e-08 9.549410900000000479e-01 1.700000000000000000e+02 -1.946440600000000116e-07 5.150142400000000188e-08 9.312095599999999918e-01 1.705000000000000000e+02 -1.889772700000000120e-07 4.813512800000000166e-08 9.023335000000000106e-01 1.710000000000000000e+02 -1.889415399999999977e-07 4.911826699999999925e-08 9.106457199999999919e-01 1.715000000000000000e+02 -1.925770299999999942e-07 5.442161599999999923e-08 9.410197099999999537e-01 1.720000000000000000e+02 -1.940940400000000036e-07 6.086131099999999475e-08 9.576578100000000537e-01 1.725000000000000000e+02 -1.948426799999999970e-07 6.519868400000000551e-08 9.579157200000000261e-01 1.730000000000000000e+02 -1.928430499999999978e-07 7.045387200000000231e-08 9.558698500000000209e-01 1.735000000000000000e+02 -1.872596900000000110e-07 7.379592399999999680e-08 9.635546200000000283e-01 1.740000000000000000e+02 -1.894575700000000034e-07 7.616333900000000398e-08 9.656084799999999913e-01 1.745000000000000000e+02 -1.939574299999999924e-07 7.977328000000000558e-08 9.641109700000000116e-01 1.750000000000000000e+02 -1.932456500000000096e-07 8.192431299999999678e-08 9.644890400000000197e-01 1.755000000000000000e+02 -1.916200900000000002e-07 8.625235600000000464e-08 9.574661300000000264e-01 1.760000000000000000e+02 -1.908292300000000082e-07 8.845280099999999745e-08 9.551604999999999679e-01 1.765000000000000000e+02 -1.865912200000000103e-07 9.196866600000000059e-08 9.562296300000000526e-01 1.770000000000000000e+02 -1.879181299999999974e-07 9.674347700000000461e-08 9.599731599999999920e-01 1.775000000000000000e+02 -1.872796699999999876e-07 1.014281400000000050e-07 9.644088699999999736e-01 1.780000000000000000e+02 -1.848919499999999895e-07 1.056134000000000026e-07 9.610225000000000017e-01 1.785000000000000000e+02 -1.857822799999999988e-07 1.068412600000000004e-07 9.607812799999999598e-01 1.790000000000000000e+02 -1.875373100000000066e-07 1.102068800000000036e-07 9.543278200000000489e-01 1.795000000000000000e+02 -1.901325000000000119e-07 1.152508000000000065e-07 8.176477599999999457e-01 1.800000000000000000e+02 -1.877766099999999894e-07 1.162619400000000064e-07 6.235364700000000093e-01 1.805000000000000000e+02 -1.814199499999999966e-07 1.239900800000000128e-07 8.483487400000000456e-01 1.810000000000000000e+02 -1.794496700000000028e-07 1.311869399999999895e-07 9.530098999999999654e-01 1.815000000000000000e+02 -1.786502399999999987e-07 1.346305100000000056e-07 9.603216100000000477e-01 1.820000000000000000e+02 -1.783502299999999928e-07 1.365198199999999898e-07 9.614752500000000035e-01 1.825000000000000000e+02 -1.771521200000000088e-07 1.424745499999999925e-07 9.598354700000000239e-01 1.830000000000000000e+02 -1.799971899999999948e-07 1.425603499999999998e-07 9.623302799999999824e-01 1.835000000000000000e+02 -1.773392300000000111e-07 1.444301299999999987e-07 9.613101499999999744e-01 1.840000000000000000e+02 -1.693170999999999988e-07 1.545874399999999879e-07 9.583665700000000287e-01 1.845000000000000000e+02 -1.614797000000000110e-07 1.622796199999999926e-07 9.502195700000000134e-01 1.850000000000000000e+02 -1.561987699999999941e-07 1.648939300000000049e-07 9.331755000000000466e-01 1.855000000000000000e+02 -1.497938899999999959e-07 1.661983599999999993e-07 9.393505500000000064e-01 1.860000000000000000e+02 -1.485528300000000122e-07 1.595099800000000105e-07 9.477251799999999449e-01 1.865000000000000000e+02 -1.525955800000000104e-07 1.543895300000000104e-07 9.499027700000000074e-01 1.870000000000000000e+02 -1.543408699999999971e-07 1.534445199999999878e-07 9.386277200000000542e-01 1.875000000000000000e+02 -1.529082400000000055e-07 1.581631800000000027e-07 9.412660000000000471e-01 1.880000000000000000e+02 -1.573117700000000121e-07 1.615886300000000130e-07 9.370877699999999866e-01 1.885000000000000000e+02 -1.594518699999999956e-07 1.664944000000000036e-07 9.366227999999999776e-01 1.890000000000000000e+02 -1.622460200000000022e-07 1.721678400000000121e-07 9.378001099999999646e-01 1.895000000000000000e+02 -1.633093699999999890e-07 1.781315399999999955e-07 9.338689399999999807e-01 1.900000000000000000e+02 -1.577644500000000002e-07 1.914509900000000017e-07 9.215923499999999491e-01 1.905000000000000000e+02 -1.438073299999999913e-07 2.061290300000000086e-07 8.779537099999999983e-01 1.910000000000000000e+02 -1.270620199999999963e-07 2.037991000000000028e-07 8.887181299999999951e-01 1.915000000000000000e+02 -1.274705999999999953e-07 1.903942500000000110e-07 9.278165099999999832e-01 1.920000000000000000e+02 -1.294285100000000097e-07 1.896220300000000051e-07 9.381675699999999507e-01 1.925000000000000000e+02 -1.285547999999999912e-07 1.887238899999999878e-07 9.350870300000000412e-01 1.930000000000000000e+02 -1.225916900000000039e-07 1.975243400000000049e-07 9.395220899999999764e-01 1.935000000000000000e+02 -1.215379799999999931e-07 1.969789700000000035e-07 9.462781000000000109e-01 1.940000000000000000e+02 -1.192848099999999981e-07 2.022255399999999994e-07 9.382419600000000415e-01 1.945000000000000000e+02 -1.206683899999999909e-07 2.093963300000000103e-07 9.368176499999999463e-01 1.950000000000000000e+02 -1.178599199999999989e-07 2.104158800000000110e-07 9.257377399999999756e-01 1.955000000000000000e+02 -1.141104400000000020e-07 2.150971999999999946e-07 9.152911299999999528e-01 1.960000000000000000e+02 -1.097498300000000054e-07 2.144778899999999946e-07 9.143267299999999764e-01 1.965000000000000000e+02 -1.059269499999999968e-07 2.122848200000000068e-07 9.108568400000000009e-01 1.970000000000000000e+02 -1.016158199999999970e-07 2.052416099999999939e-07 9.134145399999999970e-01 1.975000000000000000e+02 -9.848845700000000493e-08 2.031811700000000059e-07 9.135571099999999500e-01 1.980000000000000000e+02 -1.025540800000000053e-07 1.872532199999999933e-07 8.701530699999999729e-01 1.985000000000000000e+02 -1.393173500000000018e-07 1.837727099999999941e-07 8.095396799999999837e-01 1.990000000000000000e+02 -1.414004900000000128e-07 2.288829999999999988e-07 8.606349199999999700e-01 1.995000000000000000e+02 -1.150900999999999990e-07 2.472964099999999980e-07 9.390804799999999952e-01 2.000000000000000000e+02 -1.068384499999999981e-07 2.502644599999999979e-07 9.481106400000000045e-01 2.005000000000000000e+02 -9.708935499999999410e-08 2.503501000000000072e-07 9.500721699999999936e-01 2.010000000000000000e+02 -9.073328799999999510e-08 2.413318000000000223e-07 9.452701199999999915e-01 2.015000000000000000e+02 -8.458990699999999857e-08 2.473589099999999763e-07 9.449431900000000439e-01 2.020000000000000000e+02 -7.778457700000000549e-08 2.502084400000000207e-07 9.510693000000000064e-01 2.025000000000000000e+02 -7.898802999999999529e-08 2.485771800000000074e-07 9.511014800000000546e-01 2.030000000000000000e+02 -7.328907300000000211e-08 2.495349899999999810e-07 9.499304899999999607e-01 2.035000000000000000e+02 -6.689927500000000068e-08 2.495322599999999776e-07 9.540669299999999797e-01 2.040000000000000000e+02 -6.873948200000000571e-08 2.480492499999999803e-07 9.578290000000000415e-01 2.045000000000000000e+02 -6.047935099999999786e-08 2.521815099999999972e-07 9.576486899999999691e-01 2.050000000000000000e+02 -5.645783200000000109e-08 2.531646400000000217e-07 9.595199800000000501e-01 2.055000000000000000e+02 -5.305624400000000044e-08 2.528187200000000255e-07 9.595049599999999623e-01 2.060000000000000000e+02 -4.900644900000000306e-08 2.553714800000000116e-07 9.606638600000000361e-01 2.065000000000000000e+02 -4.541597699999999714e-08 2.544098499999999982e-07 9.588877000000000095e-01 2.070000000000000000e+02 -4.596992299999999931e-08 2.546008799999999795e-07 9.526126999999999789e-01 2.075000000000000000e+02 -4.168508399999999936e-08 2.557073600000000102e-07 9.513716100000000342e-01 2.080000000000000000e+02 -4.107795000000000289e-08 2.550744699999999826e-07 9.517968300000000381e-01 2.085000000000000000e+02 -3.804205299999999782e-08 2.591237899999999907e-07 9.572613800000000506e-01 2.090000000000000000e+02 -2.893126099999999994e-08 2.580334200000000066e-07 9.591785099999999842e-01 2.095000000000000000e+02 -2.665392400000000057e-08 2.570762099999999861e-07 9.573910799999999499e-01 2.100000000000000000e+02 -2.277526799999999986e-08 2.616057500000000131e-07 9.552032400000000090e-01 2.105000000000000000e+02 -2.336593100000000009e-08 2.579774899999999853e-07 9.437834600000000185e-01 2.110000000000000000e+02 -2.028584600000000100e-08 2.570030799999999876e-07 9.367318199999999928e-01 2.115000000000000000e+02 -1.913522500000000120e-08 2.627627999999999976e-07 9.471300799999999853e-01 2.120000000000000000e+02 -1.400428000000000078e-08 2.661066999999999856e-07 9.491801899999999792e-01 2.125000000000000000e+02 -4.197926000000000171e-09 2.687178000000000003e-07 9.456008099999999583e-01 2.130000000000000000e+02 -9.125710199999999769e-10 2.655795300000000154e-07 9.380222599999999966e-01 2.135000000000000000e+02 -4.133510899999999592e-09 2.675579900000000094e-07 9.363575600000000332e-01 2.140000000000000000e+02 3.745248100000000291e-09 2.698302499999999819e-07 9.384381200000000423e-01 2.145000000000000000e+02 7.687369900000000068e-09 2.673485500000000028e-07 9.463041399999999603e-01 2.150000000000000000e+02 9.502629800000000239e-09 2.704081200000000069e-07 9.430172999999999472e-01 2.155000000000000000e+02 1.191240999999999940e-08 2.678750699999999974e-07 9.286245100000000141e-01 2.160000000000000000e+02 1.352494499999999935e-08 2.676001700000000218e-07 9.403378399999999804e-01 2.165000000000000000e+02 1.156645299999999962e-08 2.687091599999999990e-07 9.345959999999999823e-01 2.170000000000000000e+02 9.689938599999999698e-09 2.735980900000000213e-07 9.269587999999999717e-01 2.175000000000000000e+02 1.622214699999999849e-08 2.763969200000000109e-07 9.228817200000000165e-01 2.180000000000000000e+02 2.125181099999999995e-08 2.757102499999999790e-07 9.434574799999999595e-01 2.185000000000000000e+02 2.225430499999999990e-08 2.716855900000000100e-07 9.391447899999999516e-01 2.190000000000000000e+02 2.108195599999999899e-08 2.734740599999999836e-07 9.313487999999999767e-01 2.195000000000000000e+02 2.971822400000000042e-08 2.704410099999999894e-07 9.191184599999999705e-01 2.200000000000000000e+02 3.304543499999999881e-08 2.698885200000000213e-07 9.294396600000000008e-01 2.205000000000000000e+02 3.831558399999999688e-08 2.724161999999999800e-07 9.263044000000000278e-01 2.210000000000000000e+02 4.890131700000000074e-08 2.719745599999999906e-07 9.237763900000000028e-01 2.215000000000000000e+02 5.011533599999999702e-08 2.764129799999999820e-07 9.183309100000000003e-01 2.220000000000000000e+02 4.801582099999999716e-08 2.770615300000000120e-07 9.138006600000000423e-01 2.225000000000000000e+02 5.023350599999999972e-08 2.805831499999999802e-07 9.238831400000000471e-01 2.230000000000000000e+02 5.762905500000000040e-08 2.759433100000000108e-07 9.198994600000000021e-01 2.235000000000000000e+02 6.390443699999999804e-08 2.793399899999999756e-07 9.202878500000000184e-01 2.240000000000000000e+02 6.953574400000000583e-08 2.913104999999999932e-07 9.278010100000000371e-01 2.245000000000000000e+02 6.658156299999999659e-08 2.914123100000000020e-07 9.229953899999999711e-01 2.250000000000000000e+02 7.722790899999999589e-08 2.910939499999999766e-07 9.081040599999999907e-01 2.255000000000000000e+02 8.520375200000000019e-08 2.864433100000000056e-07 8.911843299999999690e-01 2.260000000000000000e+02 9.946537499999999475e-08 2.869399499999999779e-07 8.728354000000000390e-01 2.265000000000000000e+02 1.060912800000000034e-07 2.939668799999999894e-07 8.607627700000000104e-01 2.270000000000000000e+02 1.158622500000000024e-07 2.934186800000000189e-07 7.876238800000000539e-01 2.275000000000000000e+02 1.450085399999999973e-07 2.852533200000000160e-07 7.052213000000000509e-01 2.280000000000000000e+02 1.887945300000000065e-07 2.432322499999999975e-07 5.326790200000000031e-01 2.285000000000000000e+02 1.840152899999999902e-07 2.015611399999999924e-07 3.194410500000000042e-01 2.290000000000000000e+02 1.145969600000000042e-07 1.583995999999999939e-07 1.736697899999999906e-01 2.295000000000000000e+02 5.668855600000000299e-08 1.793933699999999893e-07 1.796137399999999940e-01 2.300000000000000000e+02 2.577849399999999959e-08 2.268516099999999869e-07 3.224171699999999752e-01 2.305000000000000000e+02 1.660115400000000035e-08 2.609173200000000024e-07 4.814177800000000174e-01 2.310000000000000000e+02 2.421079099999999794e-09 2.651000600000000173e-07 4.794356200000000068e-01 2.315000000000000000e+02 -2.625259800000000112e-08 2.444051300000000187e-07 4.005870500000000001e-01 2.320000000000000000e+02 -2.168650100000000065e-08 2.610849200000000125e-07 3.946783200000000269e-01 2.325000000000000000e+02 -1.461385800000000043e-08 2.727154300000000152e-07 3.864832799999999846e-01 2.330000000000000000e+02 -1.882791899999999891e-08 2.892896600000000025e-07 3.078276200000000240e-01 2.335000000000000000e+02 -1.799832500000000112e-07 3.229497999999999793e-07 1.898252199999999890e-01 2.340000000000000000e+02 -2.142147500000000091e-07 6.039036899999999929e-07 2.467564899999999950e-01 2.345000000000000000e+02 1.603582999999999888e-07 6.390764599999999990e-07 3.648062300000000091e-01 2.350000000000000000e+02 2.024979300000000020e-07 4.276556400000000190e-07 6.692359399999999736e-01 2.355000000000000000e+02 1.276718799999999948e-07 4.106343600000000051e-07 6.628361299999999678e-01 2.360000000000000000e+02 9.777372199999999664e-08 4.441216700000000054e-07 5.506294400000000255e-01 2.365000000000000000e+02 -1.846468900000000036e-08 5.087732100000000197e-07 3.765558900000000042e-01 2.370000000000000000e+02 -1.118080800000000034e-07 8.172757999999999814e-07 3.070819399999999977e-01 2.375000000000000000e+02 1.930691700000000011e-07 1.102169399999999970e-06 3.125607699999999878e-01 2.380000000000000000e+02 5.869721299999999654e-07 9.028149700000000513e-07 3.551838700000000126e-01 2.385000000000000000e+02 7.260670700000000016e-07 6.946764300000000440e-07 4.842134100000000108e-01 2.390000000000000000e+02 6.330936299999999989e-07 5.490447300000000039e-07 4.405406099999999991e-01 2.395000000000000000e+02 7.066683500000000110e-07 4.571297399999999745e-07 4.172368300000000030e-01 2.400000000000000000e+02 8.167850200000000374e-07 1.711738099999999937e-07 3.633213299999999979e-01 2.405000000000000000e+02 5.909993800000000123e-07 5.219164100000000311e-08 1.953853200000000012e-01 2.410000000000000000e+02 2.582795599999999993e-07 -3.506672599999999763e-08 5.276980600000000243e-02 2.415000000000000000e+02 9.227156299999999701e-08 1.741721100000000081e-07 3.875806899999999916e-02 2.420000000000000000e+02 2.211821299999999967e-07 3.970522199999999783e-07 3.591868899999999809e-01 2.425000000000000000e+02 3.365809099999999794e-07 4.524259800000000110e-07 7.829068900000000220e-01 2.430000000000000000e+02 4.324730599999999901e-07 4.883918899999999683e-07 8.695474899999999785e-01 2.435000000000000000e+02 5.413360200000000172e-07 5.024382999999999655e-07 9.171082999999999874e-01 2.440000000000000000e+02 5.918116099999999674e-07 4.792324799999999804e-07 9.428700800000000548e-01 2.445000000000000000e+02 6.818806900000000300e-07 4.431813899999999884e-07 9.501433400000000029e-01 2.450000000000000000e+02 7.563593300000000358e-07 3.995401100000000181e-07 9.650593400000000432e-01 2.455000000000000000e+02 8.292983600000000276e-07 3.478566800000000197e-07 9.656649800000000061e-01 2.460000000000000000e+02 9.067994100000000240e-07 2.821617200000000256e-07 9.599145100000000541e-01 2.465000000000000000e+02 9.488709900000000434e-07 1.649748199999999889e-07 9.471465300000000420e-01 2.470000000000000000e+02 9.355601899999999955e-07 5.292329799999999920e-08 9.408779099999999840e-01 2.475000000000000000e+02 9.768704099999999372e-07 -1.965011600000000117e-08 9.449778199999999684e-01 2.480000000000000000e+02 9.807149600000000443e-07 -1.787451400000000084e-07 9.502129000000000270e-01 2.485000000000000000e+02 9.496342299999999528e-07 -2.958586300000000103e-07 9.474549300000000285e-01 2.490000000000000000e+02 8.900623199999999626e-07 -4.422293799999999844e-07 8.808258799999999500e-01 2.495000000000000000e+02 7.564267999999999902e-07 -5.183997599999999598e-07 7.025019500000000416e-01 2.500000000000000000e+02 6.100031000000000050e-07 -5.423751200000000493e-07 7.332868000000000164e-01 2.505000000000000000e+02 5.416613399999999848e-07 -5.772771499999999766e-07 8.921082599999999863e-01 2.510000000000000000e+02 4.627352199999999980e-07 -5.850973800000000432e-07 8.042358200000000457e-01 2.515000000000000000e+02 4.072025799999999821e-07 -5.570193500000000187e-07 6.544644800000000151e-01 2.520000000000000000e+02 2.950398299999999924e-07 -5.588002500000000079e-07 5.728743699999999661e-01 2.525000000000000000e+02 2.655621099999999814e-07 -5.356469599999999926e-07 6.695263399999999976e-01 2.530000000000000000e+02 2.309579399999999900e-07 -4.790263700000000360e-07 7.272838999999999832e-01 2.535000000000000000e+02 2.112521599999999894e-07 -4.434574199999999867e-07 7.754549400000000370e-01 2.540000000000000000e+02 1.495898900000000028e-07 -4.214350600000000206e-07 7.716000699999999712e-01 2.545000000000000000e+02 9.698069199999999447e-08 -3.832035400000000202e-07 7.596353900000000214e-01 2.550000000000000000e+02 8.160446900000000130e-08 -3.561350800000000047e-07 8.002367599999999914e-01 2.555000000000000000e+02 7.081950300000000523e-08 -3.489953700000000015e-07 8.101319700000000346e-01 2.560000000000000000e+02 5.981448899999999586e-08 -3.314124800000000239e-07 7.095127700000000148e-01 2.565000000000000000e+02 5.463530399999999685e-08 -3.270018599999999741e-07 7.111345500000000319e-01 2.570000000000000000e+02 2.869575200000000135e-08 -2.918875699999999750e-07 6.953232299999999588e-01 2.575000000000000000e+02 1.897919199999999908e-08 -2.724611099999999957e-07 6.787406799999999851e-01 2.580000000000000000e+02 2.687719599999999934e-08 -2.649180100000000001e-07 5.699319800000000047e-01 2.585000000000000000e+02 2.512407500000000126e-08 -2.750199399999999779e-07 4.671858799999999978e-01 2.590000000000000000e+02 -1.755029499999999931e-09 -2.388230200000000135e-07 3.116292399999999740e-01 2.595000000000000000e+02 -2.240259900000000005e-08 -1.951910799999999897e-07 2.694371600000000089e-01 2.600000000000000000e+02 -3.625441299999999839e-09 -1.860964299999999990e-07 2.958199100000000192e-01 2.605000000000000000e+02 -5.676641399999999984e-09 -1.717384499999999902e-07 2.896809599999999874e-01 2.610000000000000000e+02 1.122044800000000067e-09 -1.788985000000000055e-07 3.523055299999999779e-01 2.615000000000000000e+02 -6.847798799999999897e-09 -1.734704799999999984e-07 3.517718899999999760e-01 2.620000000000000000e+02 -9.832580999999999880e-09 -1.352062800000000097e-07 2.239701600000000015e-01 2.625000000000000000e+02 1.143291999999999985e-08 -1.118347199999999986e-07 1.519691900000000040e-01 2.630000000000000000e+02 -7.142280999999999771e-09 -1.247802400000000067e-07 1.592576500000000006e-01 2.635000000000000000e+02 -1.553764599999999956e-08 -1.597285999999999921e-07 2.036408600000000069e-01 2.640000000000000000e+02 -1.884461800000000165e-08 -1.779266099999999905e-07 1.935536099999999871e-01 2.645000000000000000e+02 -1.410885800000000021e-08 -1.588425499999999972e-07 1.808273900000000045e-01 2.650000000000000000e+02 -2.279439700000000048e-09 -1.325459200000000021e-07 1.422381000000000062e-01 2.655000000000000000e+02 -6.334674099999999657e-09 -9.874842300000000436e-08 8.512830700000000028e-02 2.660000000000000000e+02 -6.700300300000000212e-09 -1.168769000000000028e-07 1.373403400000000052e-01 2.665000000000000000e+02 -3.436230100000000024e-08 -9.707242299999999650e-08 1.033613800000000027e-01 2.670000000000000000e+02 -6.707662000000000199e-09 -8.221692100000000554e-08 6.325601799999999719e-02 2.675000000000000000e+02 -1.052524399999999997e-08 -8.044268899999999789e-08 4.394307399999999864e-02 2.680000000000000000e+02 -3.751537699999999983e-08 -9.487415300000000549e-08 4.900240200000000046e-02 2.685000000000000000e+02 -2.469918500000000108e-08 -8.710935599999999703e-08 2.963515400000000036e-02 2.690000000000000000e+02 -2.242560300000000094e-08 -7.174345699999999937e-08 2.210429100000000160e-02 2.695000000000000000e+02 -2.773739499999999901e-08 -4.592090600000000119e-08 1.351526299999999958e-02 2.700000000000000000e+02 -5.171383700000000004e-08 -3.222533699999999728e-08 1.848432800000000126e-02 2.705000000000000000e+02 -3.986517400000000249e-08 -4.722306800000000057e-08 2.593504099999999896e-02 2.710000000000000000e+02 -2.594851600000000085e-08 -3.897773499999999827e-08 1.882262700000000150e-02 2.715000000000000000e+02 -3.445575600000000259e-08 -3.897834900000000209e-08 2.831565000000000124e-02 2.720000000000000000e+02 -3.610610500000000288e-08 -2.304090099999999920e-08 2.719051600000000138e-02 2.725000000000000000e+02 -7.449926500000000268e-09 -4.650624799999999932e-08 3.236877199999999705e-02 2.730000000000000000e+02 -4.606425900000000125e-09 -6.708698700000000293e-08 6.419377800000000689e-02 2.735000000000000000e+02 -1.065596000000000008e-08 -5.252524800000000180e-08 5.218127399999999971e-02 2.740000000000000000e+02 -2.347765199999999845e-08 -2.982452700000000214e-08 2.304229899999999873e-02 2.745000000000000000e+02 8.076131799999999650e-09 -2.881650299999999962e-08 1.039512400000000038e-02 2.750000000000000000e+02 3.303371399999999969e-09 -2.602128099999999879e-08 6.199591800000000229e-03 2.755000000000000000e+02 1.009835800000000046e-08 -5.728923800000000077e-08 2.085497999999999866e-02 2.760000000000000000e+02 -1.121718600000000019e-08 -5.712684000000000122e-08 2.449597800000000158e-02 2.765000000000000000e+02 -3.287602700000000137e-08 -2.243356400000000089e-08 1.396458599999999932e-02 2.770000000000000000e+02 -3.033618899999999850e-08 -2.799973400000000050e-08 1.505768799999999963e-02 2.775000000000000000e+02 -2.061807400000000016e-08 -3.218621099999999892e-08 1.411825599999999917e-02 2.780000000000000000e+02 -2.992238599999999883e-08 -4.654754400000000120e-08 2.704732500000000053e-02 2.785000000000000000e+02 -4.960744700000000231e-08 -3.082229599999999805e-08 2.245006199999999980e-02 2.790000000000000000e+02 -1.506965200000000019e-08 -1.552104200000000063e-08 3.702564900000000075e-03 2.795000000000000000e+02 -2.384302500000000101e-09 -1.139307699999999957e-08 1.257084799999999948e-03 2.800000000000000000e+02 -6.939307799999999813e-09 -7.246952400000000023e-09 1.261561299999999905e-03 2.805000000000000000e+02 -3.862327800000000374e-09 -2.970577399999999888e-08 9.690946000000000629e-03 2.810000000000000000e+02 -7.230798199999999727e-09 -3.572354000000000008e-09 7.064925199999999529e-04 2.815000000000000000e+02 3.946462899999999929e-10 2.847530399999999951e-08 6.968750600000000323e-03 2.820000000000000000e+02 1.116079699999999963e-08 -8.464171600000000658e-09 1.845576499999999984e-03 2.825000000000000000e+02 1.786461600000000150e-08 -7.004361999999999805e-09 4.528698999999999746e-03 2.830000000000000000e+02 1.544228899999999972e-08 -8.148321999999999648e-09 4.024161499999999794e-03 2.835000000000000000e+02 -8.221330300000000697e-09 -4.203394499999999675e-09 1.006261299999999933e-03 2.840000000000000000e+02 -1.013395000000000056e-08 -1.154881299999999967e-08 2.752680799999999810e-03 2.845000000000000000e+02 -2.299813000000000028e-08 5.646296299999999888e-09 5.017200000000000305e-03 2.850000000000000000e+02 -4.066701199999999998e-09 1.021473400000000039e-08 7.740081599999999772e-04 2.855000000000000000e+02 -2.015260800000000180e-09 8.655272899999999719e-09 4.913831399999999501e-04 2.860000000000000000e+02 -8.359121399999999597e-09 -1.406377500000000048e-08 1.339335000000000091e-03 2.865000000000000000e+02 2.128266499999999849e-09 3.471090400000000142e-08 5.302346799999999721e-03 2.870000000000000000e+02 -2.156141800000000120e-08 -7.612273500000000100e-09 2.546866200000000129e-03 2.875000000000000000e+02 -1.134976400000000035e-09 -3.469176600000000206e-08 7.578825600000000176e-03 2.880000000000000000e+02 2.504942699999999864e-08 -2.033574399999999872e-08 8.452080199999999904e-03 2.885000000000000000e+02 2.619472799999999996e-08 -7.785224900000000451e-09 8.696317699999999221e-03 2.890000000000000000e+02 2.810631399999999869e-10 3.668924299999999905e-09 2.118682499999999887e-04 2.895000000000000000e+02 -8.753387300000000073e-09 1.110450999999999932e-09 1.306122600000000043e-03 2.900000000000000000e+02 -7.418460299999999726e-10 2.309123100000000145e-09 8.665222399999999579e-05 2.905000000000000000e+02 -3.682900699999999985e-09 -7.958861999999999353e-09 1.257028899999999968e-03 2.910000000000000000e+02 -6.466169400000000032e-09 -5.043760099999999994e-09 1.228135399999999910e-03 2.915000000000000000e+02 -1.704478299999999842e-08 -5.136232300000000066e-09 6.094210299999999747e-03 2.920000000000000000e+02 -1.339607799999999970e-08 -3.016683799999999939e-09 3.442778999999999978e-03 2.925000000000000000e+02 3.729320400000000232e-09 1.152527699999999959e-08 2.289613700000000043e-03 2.930000000000000000e+02 1.238071199999999934e-08 1.331536699999999915e-09 2.207088700000000084e-03 2.935000000000000000e+02 7.675297099999999858e-10 1.543186900000000008e-08 2.933670099999999802e-03 2.940000000000000000e+02 -9.880648500000000965e-10 -6.539830899999999612e-10 1.383965000000000055e-05 2.945000000000000000e+02 2.227565900000000090e-08 -1.816578900000000091e-08 5.995404400000000321e-03 2.950000000000000000e+02 3.085859400000000152e-08 3.799286199999999717e-08 1.142447000000000080e-02 2.955000000000000000e+02 4.952322599999999874e-08 2.605069799999999916e-08 1.061200399999999953e-02 2.960000000000000000e+02 1.711606900000000135e-08 1.043515799999999955e-08 1.169526300000000045e-03 2.965000000000000000e+02 -1.705709000000000070e-08 5.625848600000000263e-08 7.806729499999999836e-03 2.970000000000000000e+02 -5.433410900000000035e-08 9.089661500000000293e-09 6.910288700000000346e-03 2.975000000000000000e+02 -2.399835200000000059e-08 2.398352599999999934e-08 2.270044499999999878e-03 2.980000000000000000e+02 7.559285099999999618e-08 6.920524199999999440e-08 1.534103499999999939e-02 2.985000000000000000e+02 6.922983399999999856e-08 9.107188200000000523e-08 1.283232299999999965e-02 2.990000000000000000e+02 1.528238300000000045e-08 -6.367871899999999710e-08 1.761745299999999993e-03 2.995000000000000000e+02 2.843308699999999851e-07 -3.730774299999999976e-08 9.307934900000000220e-03 3.000000000000000000e+02 1.697575099999999998e-07 -4.435273499999999842e-08 5.753557200000000357e-03 3.005000000000000000e+02 -3.158591800000000106e-09 1.588450999999999895e-08 3.905030599999999752e-04 3.010000000000000000e+02 -3.254005799999999752e-08 1.465244099999999941e-08 3.541878699999999845e-03 3.015000000000000000e+02 -2.409544200000000031e-08 -2.544602399999999940e-08 4.011249199999999786e-03 3.020000000000000000e+02 5.438449700000000206e-08 -7.644756300000000037e-08 1.020922099999999923e-02 3.025000000000000000e+02 4.888906700000000008e-08 -3.350230699999999975e-08 3.990848499999999702e-03 3.030000000000000000e+02 -2.124190200000000108e-08 -1.538486499999999845e-08 3.176721500000000142e-04 3.035000000000000000e+02 -7.693029900000000067e-08 -8.618436600000000021e-09 2.201261199999999998e-03 3.040000000000000000e+02 1.097194800000000054e-08 2.551237300000000020e-08 1.404654900000000062e-03 3.045000000000000000e+02 1.738883899999999937e-08 8.539648599999999527e-08 1.564930399999999930e-02 3.050000000000000000e+02 1.416320999999999994e-08 5.112773800000000214e-08 3.934592500000000381e-03 3.055000000000000000e+02 4.026802000000000008e-08 2.885845699999999950e-08 2.682543800000000180e-03 3.060000000000000000e+02 7.226909600000000097e-08 1.232063700000000004e-08 5.835459599999999643e-03 3.065000000000000000e+02 1.442080099999999999e-08 -2.206655499999999877e-08 1.133241799999999948e-03 3.070000000000000000e+02 -3.253357400000000187e-08 3.101320400000000002e-08 2.946139500000000133e-03 3.075000000000000000e+02 -5.858093499999999650e-10 7.935413000000000543e-08 6.261938300000000415e-03 3.080000000000000000e+02 -4.519523599999999785e-08 1.252122199999999972e-08 2.311771499999999962e-03 3.085000000000000000e+02 2.766811800000000121e-08 2.010806600000000165e-08 1.004342999999999989e-03 3.090000000000000000e+02 8.663134600000000108e-08 -3.159811300000000073e-09 5.058003600000000356e-03 3.095000000000000000e+02 7.384777199999999408e-08 -1.003623300000000016e-07 9.265193700000000365e-03 3.100000000000000000e+02 9.727892799999999733e-08 5.949832599999999917e-09 4.899154000000000182e-03 3.105000000000000000e+02 2.024467699999999990e-08 6.669118599999999784e-08 2.042644399999999846e-03 3.110000000000000000e+02 -7.428475599999999481e-08 8.135270900000000381e-08 3.419302400000000068e-03 3.115000000000000000e+02 2.265397500000000086e-08 3.617459400000000095e-08 3.823150799999999933e-04 3.120000000000000000e+02 1.606317999999999945e-07 2.991138399999999896e-08 4.418000600000000257e-03 3.125000000000000000e+02 1.588105499999999874e-07 4.077844599999999949e-08 3.831520000000000151e-03 3.130000000000000000e+02 1.095994699999999985e-07 1.953066499999999908e-07 9.127898100000000209e-03 3.135000000000000000e+02 -9.314578599999999704e-08 8.832168399999999359e-08 4.019802400000000407e-03 3.140000000000000000e+02 -7.345288099999999452e-08 1.287697300000000075e-07 7.534377299999999757e-03 3.145000000000000000e+02 -1.763707599999999879e-07 7.403996700000000595e-08 1.468727600000000084e-02 3.150000000000000000e+02 -1.311888800000000124e-07 3.141593699999999799e-08 1.014984499999999935e-02 3.155000000000000000e+02 -7.412820200000000528e-08 1.079087799999999997e-07 1.238755499999999975e-02 3.160000000000000000e+02 -8.762454199999999840e-08 5.324546800000000161e-08 7.562401199999999914e-03 3.165000000000000000e+02 -4.499443300000000147e-08 -4.562771100000000053e-08 3.183173200000000147e-03 3.170000000000000000e+02 -2.245591399999999844e-08 -2.673900400000000003e-08 1.011808799999999947e-03 3.175000000000000000e+02 -2.285120000000000149e-08 -7.274791899999999635e-09 5.550560300000000492e-04 3.180000000000000000e+02 -1.734957800000000099e-08 9.914446200000000260e-09 4.438065799999999991e-04 3.185000000000000000e+02 -3.924749599999999994e-08 5.064650199999999692e-08 4.587012300000000223e-03 3.190000000000000000e+02 -3.098709600000000228e-08 3.373605400000000246e-08 2.304856699999999897e-03 3.195000000000000000e+02 5.299189699999999924e-08 -7.333535699999999921e-08 7.888876799999999800e-03 3.200000000000000000e+02 2.831114200000000013e-08 -1.126177599999999993e-07 1.015733499999999997e-02 3.205000000000000000e+02 1.114140700000000059e-09 -1.102323800000000060e-07 8.297004700000000857e-03 3.210000000000000000e+02 1.594982300000000037e-08 -1.242092099999999915e-07 1.346135799999999966e-02 3.215000000000000000e+02 -7.627132000000000458e-08 -6.573004899999999936e-08 7.199512299999999594e-03 3.220000000000000000e+02 -5.429358999999999800e-08 -3.373416699999999982e-08 1.504616999999999977e-03 3.225000000000000000e+02 -6.202880300000000579e-08 3.429330199999999842e-09 2.308128600000000207e-03 3.230000000000000000e+02 -8.689586700000000660e-08 9.794947100000000701e-09 6.380795499999999607e-03 3.235000000000000000e+02 4.101994899999999926e-10 -2.099770599999999859e-09 3.574014699999999962e-06 3.240000000000000000e+02 -3.641477500000000322e-08 -5.543689200000000068e-08 4.393117999999999676e-03 3.245000000000000000e+02 -4.646341999999999711e-09 -2.613260900000000008e-09 2.653312199999999861e-05 3.250000000000000000e+02 -1.068962400000000035e-07 -1.038302200000000013e-07 2.074165999999999857e-02 3.255000000000000000e+02 -1.848016100000000041e-07 -1.267374000000000004e-07 5.689287199999999711e-02 3.260000000000000000e+02 -5.142630500000000132e-08 -1.009744600000000025e-07 1.670228299999999833e-02 3.265000000000000000e+02 -6.431400100000000632e-08 -2.565851699999999989e-08 6.511651900000000118e-03 3.270000000000000000e+02 -5.243922999999999780e-08 4.811720399999999720e-09 3.030756999999999809e-03 3.275000000000000000e+02 -1.009555699999999961e-07 -1.556036999999999920e-07 3.617745299999999831e-02 3.280000000000000000e+02 -9.739932200000000091e-08 -9.425455999999999799e-08 2.074464999999999990e-02 3.285000000000000000e+02 -1.545710299999999912e-07 -7.488693399999999964e-08 3.103230100000000172e-02 3.290000000000000000e+02 -2.153899899999999886e-07 -9.285181999999999876e-08 6.195535900000000151e-02 3.295000000000000000e+02 -2.392448000000000116e-07 -7.999217599999999577e-08 7.636285600000000673e-02 3.300000000000000000e+02 -1.135159499999999995e-07 -6.120728100000000033e-08 2.025649300000000042e-02 3.305000000000000000e+02 -1.456239899999999977e-07 -8.418270899999999673e-08 2.659221700000000133e-02 3.310000000000000000e+02 -3.037782799999999921e-07 -1.198871000000000121e-07 8.713971800000000489e-02 3.315000000000000000e+02 -2.822226300000000065e-07 -1.819360299999999984e-07 9.995259300000000624e-02 3.320000000000000000e+02 -1.977072900000000046e-07 -8.619588999999999774e-08 4.489310500000000259e-02 3.325000000000000000e+02 -1.683354000000000000e-07 -1.274030100000000026e-07 4.292513099999999832e-02 3.330000000000000000e+02 -2.497438299999999817e-07 -6.247272200000000367e-08 6.678904600000000469e-02 3.335000000000000000e+02 -2.548609599999999822e-07 -7.331914299999999888e-08 6.169739400000000262e-02 3.340000000000000000e+02 -2.570319599999999823e-07 -8.823853599999999788e-08 6.571251200000000070e-02 3.345000000000000000e+02 -2.419491800000000092e-07 -9.603855500000000430e-08 5.973585700000000331e-02 3.350000000000000000e+02 -2.563774600000000210e-07 -6.960323899999999806e-08 6.512405699999999908e-02 3.355000000000000000e+02 -2.920058100000000265e-07 -1.115647700000000062e-07 9.540230800000000511e-02 3.360000000000000000e+02 -3.206026199999999737e-07 -1.054765899999999938e-07 1.018283700000000014e-01 3.365000000000000000e+02 -4.152717000000000114e-07 -8.034770399999999752e-08 1.339661900000000128e-01 3.370000000000000000e+02 -3.926942599999999992e-07 -4.649574199999999873e-08 1.135037500000000005e-01 3.375000000000000000e+02 -3.277021999999999895e-07 -2.719415999999999990e-08 6.952440699999999640e-02 3.380000000000000000e+02 -4.663909000000000182e-07 -4.985069400000000255e-08 1.141398799999999991e-01 3.385000000000000000e+02 -4.699816099999999941e-07 -1.132478799999999975e-07 1.026220000000000049e-01 3.390000000000000000e+02 -4.163545399999999973e-07 -9.450591400000000502e-08 5.605278899999999870e-02 3.395000000000000000e+02 -3.909640900000000149e-07 -5.412473700000000212e-08 4.053048800000000340e-02 3.400000000000000000e+02 -5.751036300000000468e-07 -1.382446000000000096e-07 8.047505500000000367e-02 3.405000000000000000e+02 -5.260779399999999486e-07 -1.222209399999999872e-07 5.211488899999999758e-02 3.410000000000000000e+02 -4.348554799999999795e-07 1.359012600000000006e-08 2.837951899999999889e-02 3.415000000000000000e+02 -5.895402099999999911e-07 6.540496900000000238e-08 4.138882499999999715e-02 3.420000000000000000e+02 -5.674743300000000222e-07 -1.853872900000000107e-07 3.220757800000000060e-02 3.425000000000000000e+02 -3.927222000000000251e-07 -2.482989000000000000e-07 1.517817100000000072e-02 3.430000000000000000e+02 -7.116484499999999855e-07 -1.679932400000000112e-07 3.335300100000000018e-02 3.435000000000000000e+02 -6.068661900000000302e-07 3.387928599999999769e-07 2.956143799999999891e-02 3.440000000000000000e+02 -7.376435200000000431e-07 5.608532699999999996e-07 3.420247500000000301e-02 3.445000000000000000e+02 -1.021430599999999908e-06 9.153236000000000026e-07 6.106207100000000249e-02 3.450000000000000000e+02 -9.573723199999998950e-07 7.273234200000000485e-07 4.633192700000000191e-02 3.455000000000000000e+02 -1.083676199999999953e-06 1.321409799999999988e-07 3.095395299999999933e-02 3.460000000000000000e+02 -9.907813600000000450e-07 8.666194899999999901e-08 1.959095199999999828e-02 3.465000000000000000e+02 -5.220555899999999947e-07 7.320871299999999516e-07 1.417718599999999961e-02 3.470000000000000000e+02 -1.225585699999999971e-06 4.861985299999999609e-07 2.595659900000000034e-02 3.475000000000000000e+02 -1.259735400000000072e-06 1.307246900000000040e-06 4.823518200000000145e-02 3.480000000000000000e+02 -1.381132600000000094e-06 1.237804299999999961e-06 5.077463000000000115e-02 3.485000000000000000e+02 -1.779170899999999945e-06 1.063064899999999978e-06 5.043804300000000185e-02 3.490000000000000000e+02 -1.669575600000000078e-06 9.024740800000000372e-07 4.519186499999999773e-02 3.495000000000000000e+02 -8.028055199999999750e-07 1.414896199999999977e-06 4.258144299999999660e-02 3.500000000000000000e+02 -1.120261599999999928e-06 1.292722299999999924e-06 5.165890199999999960e-02 3.505000000000000000e+02 -1.520763399999999913e-06 1.101218200000000098e-06 7.044862200000000241e-02 3.510000000000000000e+02 -1.073313599999999950e-06 2.173656000000000098e-06 1.397779700000000014e-01 3.515000000000000000e+02 -6.979439600000000330e-07 2.129005200000000088e-06 2.052152299999999985e-01 3.520000000000000000e+02 -9.433781000000000107e-07 2.142446600000000078e-06 3.822571300000000005e-01 3.525000000000000000e+02 -8.448843700000000024e-07 2.189161700000000128e-06 3.670075799999999999e-01 3.530000000000000000e+02 -5.717375899999999495e-07 2.263289599999999964e-06 2.127821400000000085e-01 3.535000000000000000e+02 -2.998027100000000081e-07 2.446655999999999856e-06 2.079154000000000002e-01 3.540000000000000000e+02 -3.872337100000000185e-07 2.435729600000000045e-06 2.289483800000000069e-01 3.545000000000000000e+02 1.091199699999999974e-07 2.112295800000000099e-06 1.879876900000000128e-01 3.550000000000000000e+02 4.261024499999999775e-07 1.941750000000000086e-06 1.653699899999999945e-01 3.555000000000000000e+02 7.311667799999999681e-07 2.194548899999999842e-06 2.453574500000000047e-01 3.560000000000000000e+02 4.025906199999999797e-07 1.969474899999999953e-06 1.851833900000000033e-01 3.565000000000000000e+02 6.187634100000000513e-07 1.664143499999999909e-06 2.065077100000000110e-01 3.570000000000000000e+02 7.051211799999999959e-07 1.723580200000000070e-06 2.370766099999999932e-01 3.575000000000000000e+02 1.044066799999999937e-06 1.794417399999999936e-06 2.949891399999999830e-01 3.580000000000000000e+02 8.602584099999999516e-07 1.553907199999999924e-06 2.828588499999999950e-01 3.585000000000000000e+02 8.305632899999999640e-07 1.375324700000000012e-06 2.248214199999999940e-01 3.590000000000000000e+02 1.160238500000000030e-06 1.217637299999999989e-06 2.357338400000000000e-01 3.595000000000000000e+02 1.187331199999999937e-06 1.267553299999999945e-06 2.554708099999999926e-01 3.600000000000000000e+02 1.159171199999999982e-06 9.941945799999999750e-07 1.453140199999999882e-01 3.605000000000000000e+02 1.037485399999999997e-06 9.086996900000000178e-07 1.066582900000000028e-01 3.610000000000000000e+02 1.235343799999999910e-06 5.773941299999999573e-07 1.140596100000000057e-01 3.615000000000000000e+02 1.323479900000000051e-06 1.269948399999999926e-06 2.438401699999999950e-01 3.620000000000000000e+02 1.413635899999999895e-06 1.091584700000000040e-06 2.383604800000000135e-01 3.625000000000000000e+02 1.131750099999999945e-06 8.047303999999999490e-07 1.514188099999999870e-01 3.630000000000000000e+02 1.098528100000000020e-06 6.326977199999999822e-07 1.193671800000000033e-01 3.635000000000000000e+02 1.041781300000000059e-06 3.894425599999999940e-07 9.341865800000000164e-02 3.640000000000000000e+02 1.128343900000000069e-06 5.098001999999999568e-07 1.168893599999999977e-01 3.645000000000000000e+02 9.221401999999999553e-07 4.175705300000000163e-07 7.292069499999999371e-02 3.650000000000000000e+02 7.939617600000000287e-07 3.707025700000000094e-07 5.282444499999999765e-02 3.655000000000000000e+02 8.804327600000000094e-07 3.458227699999999986e-07 5.702454600000000234e-02 3.660000000000000000e+02 9.475647900000000076e-07 4.027340000000000115e-07 8.014583599999999808e-02 3.665000000000000000e+02 1.007437499999999958e-06 4.546911299999999735e-07 9.086481500000000155e-02 3.670000000000000000e+02 1.152067899999999971e-06 6.341558100000000032e-07 9.481532099999999408e-02 3.675000000000000000e+02 1.012112999999999952e-06 6.808339800000000271e-07 9.848951499999999970e-02 3.680000000000000000e+02 8.082483300000000314e-07 2.441345499999999909e-07 6.802835299999999974e-02 3.685000000000000000e+02 1.045226600000000104e-06 2.316261500000000005e-07 1.121157500000000001e-01 3.690000000000000000e+02 1.154038700000000078e-06 3.262492799999999820e-07 1.320566499999999976e-01 3.695000000000000000e+02 8.471448600000000015e-07 -1.291143399999999998e-08 4.033769699999999875e-02 3.700000000000000000e+02 7.614163500000000457e-07 -1.736660900000000037e-08 3.011444200000000168e-02 3.705000000000000000e+02 9.111112099999999528e-07 1.493414599999999882e-07 7.126069799999999732e-02 3.710000000000000000e+02 8.759411700000000030e-07 2.507972900000000121e-07 7.623985399999999579e-02 3.715000000000000000e+02 1.044450600000000071e-06 3.056390799999999739e-07 1.091212200000000049e-01 3.720000000000000000e+02 9.936929900000000990e-07 3.433099499999999990e-07 9.334700599999999626e-02 3.725000000000000000e+02 1.009648500000000003e-06 3.310146300000000109e-07 1.077429399999999954e-01 3.730000000000000000e+02 8.185572800000000253e-07 2.698822400000000046e-07 7.514371000000000245e-02 3.735000000000000000e+02 6.997743199999999729e-07 2.289422700000000128e-07 5.111376900000000334e-02 3.740000000000000000e+02 1.012181200000000014e-06 3.978533400000000248e-07 1.002152600000000005e-01 3.745000000000000000e+02 1.057914000000000032e-06 5.849400999999999877e-07 1.044751500000000027e-01 3.750000000000000000e+02 6.523565599999999619e-07 5.046234700000000158e-07 4.473469800000000329e-02 3.755000000000000000e+02 8.285881000000000264e-07 5.613030799999999927e-08 4.320015800000000239e-02 3.760000000000000000e+02 7.216581299999999579e-07 2.471202500000000122e-07 3.034172400000000047e-02 3.765000000000000000e+02 1.122315399999999997e-06 3.179003200000000039e-07 4.602804399999999713e-02 3.770000000000000000e+02 1.316765299999999949e-06 -2.281342199999999939e-08 3.402409700000000314e-02 3.775000000000000000e+02 1.440960300000000036e-06 7.870079300000000128e-07 3.107658400000000085e-02 3.780000000000000000e+02 6.954640000000000129e-07 9.824052500000001009e-07 1.849014499999999950e-02 3.785000000000000000e+02 1.020159999999999945e-06 6.844089200000000251e-07 2.453493099999999941e-02 3.790000000000000000e+02 5.123728200000000401e-07 1.672760600000000011e-07 7.337341100000000296e-03 3.795000000000000000e+02 1.702676000000000046e-07 -1.562537299999999908e-07 1.899828400000000026e-03 3.800000000000000000e+02 9.239390700000000148e-07 -2.285620899999999878e-07 3.645242399999999716e-02 3.805000000000000000e+02 9.621189700000000641e-07 -3.869994300000000080e-07 4.888120700000000290e-02 3.810000000000000000e+02 6.399955100000000313e-07 -3.063844399999999806e-07 2.308645700000000120e-02 3.815000000000000000e+02 4.756468299999999896e-07 -1.088036800000000033e-07 1.238737200000000066e-02 3.820000000000000000e+02 5.867083800000000435e-07 2.317486999999999899e-07 1.992277099999999884e-02 3.825000000000000000e+02 4.365587400000000214e-07 6.197618099999999340e-08 1.063845400000000031e-02 3.830000000000000000e+02 4.979111699999999988e-07 -3.177956700000000162e-08 1.299634300000000048e-02 3.835000000000000000e+02 9.828957000000000125e-07 -1.954884000000000050e-07 3.497818899999999981e-02 3.840000000000000000e+02 7.532173600000000229e-07 -4.080413900000000060e-07 1.941333900000000168e-02 3.845000000000000000e+02 -2.973114199999999895e-08 -1.171057700000000027e-07 3.363455800000000060e-04 3.850000000000000000e+02 2.846434900000000138e-08 -9.470812000000000196e-08 2.130249299999999960e-04 3.855000000000000000e+02 -1.466375999999999975e-07 -8.445593400000000280e-07 1.744653499999999913e-02 3.860000000000000000e+02 5.521625500000000145e-08 -7.440582400000000281e-07 1.355688399999999995e-02 3.865000000000000000e+02 1.282658399999999939e-07 -1.216111699999999975e-07 6.942735100000000477e-04 3.870000000000000000e+02 9.362651100000000018e-07 -7.253894600000000123e-08 1.925312900000000077e-02 3.875000000000000000e+02 1.138823799999999943e-06 -4.368064599999999752e-07 3.392735499999999932e-02 3.880000000000000000e+02 6.108095899999999965e-07 -2.516910599999999797e-07 7.987456400000000553e-03 3.885000000000000000e+02 1.559715600000000073e-07 -6.283228799999999692e-07 9.812651199999999560e-03 3.890000000000000000e+02 4.975938899999999736e-08 1.224359099999999898e-07 4.247152800000000080e-04 3.895000000000000000e+02 5.940467000000000488e-07 2.752671500000000073e-08 7.444110700000000115e-03 3.900000000000000000e+02 7.123130700000000229e-07 2.559626599999999847e-08 1.036198500000000064e-02 3.905000000000000000e+02 7.913765800000000180e-07 -5.134588199999999481e-07 1.824008099999999827e-02 3.910000000000000000e+02 5.758131999999999802e-07 -9.951334999999999819e-08 6.728573699999999651e-03 3.915000000000000000e+02 3.947542099999999832e-07 -1.592270699999999896e-07 3.325229700000000097e-03 3.920000000000000000e+02 -1.731999499999999931e-07 -1.424967699999999949e-07 7.556590099999999565e-04 3.925000000000000000e+02 3.189801399999999932e-07 -6.208355100000000106e-08 1.346253800000000002e-03 3.930000000000000000e+02 2.096129599999999995e-07 5.984147799999999980e-09 5.175303100000000489e-04 3.935000000000000000e+02 2.283176600000000042e-07 2.953318000000000029e-07 1.334122400000000005e-03 3.940000000000000000e+02 -6.596363299999999710e-07 1.648130699999999974e-07 3.559735599999999840e-03 3.945000000000000000e+02 1.502845800000000104e-07 -7.018765599999999977e-07 2.945590300000000203e-03 3.950000000000000000e+02 1.523193500000000013e-06 -7.198376600000000009e-07 1.357580899999999945e-02 3.955000000000000000e+02 1.254532700000000051e-06 -1.259717499999999938e-06 1.417077400000000056e-02 3.960000000000000000e+02 8.367584299999999526e-07 -1.135956800000000001e-06 1.134042900000000083e-02 3.965000000000000000e+02 1.632861199999999931e-06 -1.477064300000000106e-07 2.126707499999999987e-02 3.970000000000000000e+02 3.522308099999999983e-07 4.363450599999999867e-07 2.919150499999999867e-03 3.975000000000000000e+02 7.340627799999999697e-07 -3.021303600000000018e-07 7.614210199999999797e-03 3.980000000000000000e+02 1.373986200000000016e-06 -5.465186600000000091e-07 3.209402000000000088e-02 3.985000000000000000e+02 9.237647300000000135e-07 -5.282217900000000357e-07 1.928203699999999840e-02 3.990000000000000000e+02 1.725195600000000043e-07 -1.622636000000000078e-07 1.123840299999999967e-03 3.995000000000000000e+02 2.181441400000000027e-07 1.724291300000000100e-07 1.743448500000000043e-03 4.000000000000000000e+02 4.140047199999999972e-07 3.389317000000000041e-07 5.698361400000000014e-03 4.005000000000000000e+02 8.518803699999999944e-07 6.789223299999999757e-07 2.044014599999999932e-02 4.010000000000000000e+02 5.830648299999999791e-07 1.658955099999999881e-07 5.933764900000000099e-03 4.015000000000000000e+02 2.524819000000000051e-07 -6.394306499999999779e-07 6.742975200000000079e-03 4.020000000000000000e+02 1.954787900000000055e-07 -1.046236500000000092e-06 1.397329800000000032e-02 4.025000000000000000e+02 4.769675600000000052e-07 -2.812951199999999905e-07 3.331301699999999859e-03 4.030000000000000000e+02 9.857658399999999101e-07 8.825099900000000489e-07 2.032683600000000090e-02 4.035000000000000000e+02 4.995509399999999653e-07 3.285550999999999851e-07 4.156382299999999801e-03 4.040000000000000000e+02 8.133035900000000097e-07 -2.064940400000000088e-07 8.552109800000000719e-03 4.045000000000000000e+02 4.638267800000000108e-07 3.216181899999999895e-07 3.775756999999999811e-03 4.050000000000000000e+02 -2.824036199999999902e-07 2.923808899999999743e-07 2.066314699999999890e-03 4.055000000000000000e+02 5.791962500000000140e-08 8.649151900000000137e-07 7.407780699999999899e-03 4.060000000000000000e+02 2.451362499999999991e-08 1.423726199999999984e-06 1.471142599999999967e-02 4.065000000000000000e+02 3.794356100000000117e-08 1.027841699999999997e-06 4.435808400000000422e-03 4.070000000000000000e+02 -2.739529100000000091e-07 -4.377241100000000112e-07 7.344966900000000172e-04 4.075000000000000000e+02 1.060759900000000091e-06 9.503117400000000162e-09 2.585955200000000093e-03 4.080000000000000000e+02 2.199255100000000027e-06 6.729309199999999802e-07 1.416488599999999980e-02 4.085000000000000000e+02 -5.946427599999999894e-07 -5.558460999999999787e-07 2.766259699999999884e-03 4.090000000000000000e+02 1.819948600000000045e-07 -1.075978699999999973e-06 8.201446399999999526e-03 4.095000000000000000e+02 6.481509400000000121e-07 -7.925672800000000420e-07 8.784000800000000414e-03 4.100000000000000000e+02 -1.102071600000000002e-07 -7.062765199999999714e-07 4.110373599999999836e-03 4.105000000000000000e+02 -8.949330099999999939e-07 -9.963436299999999727e-08 5.830898400000000294e-03 4.110000000000000000e+02 -3.634478700000000046e-08 -3.750068099999999900e-07 9.273415200000000198e-04 4.115000000000000000e+02 -9.753850299999999454e-08 -2.380126300000000096e-07 4.343028999999999987e-04 4.120000000000000000e+02 -7.011460599999999502e-07 6.053824799999999553e-08 2.753870299999999945e-03 4.125000000000000000e+02 4.514818700000000239e-07 -9.478118600000000651e-08 1.270709899999999948e-03 4.130000000000000000e+02 1.450178299999999954e-06 -3.852820199999999884e-07 1.530344200000000043e-02 4.135000000000000000e+02 1.622829699999999951e-07 -2.685300500000000058e-08 1.773404800000000128e-04 4.140000000000000000e+02 1.846476300000000079e-07 -1.493663700000000077e-07 4.241337299999999966e-04 4.145000000000000000e+02 4.850394900000000104e-07 -1.334768100000000023e-06 1.650048999999999960e-02 4.150000000000000000e+02 6.874504399999999863e-07 -7.842158400000000145e-07 9.688690300000000338e-03 4.155000000000000000e+02 6.332937800000000287e-07 -2.091834800000000085e-08 4.394791999999999796e-03 4.160000000000000000e+02 7.875299700000000616e-08 -2.704753400000000074e-07 7.597021800000000515e-04 4.165000000000000000e+02 -8.594771000000000325e-07 7.926806900000000428e-08 6.619424999999999962e-03 4.170000000000000000e+02 -8.865529800000000178e-07 -2.680545800000000122e-07 8.639165199999999933e-03 4.175000000000000000e+02 -7.474161399999999791e-08 -7.851877400000000392e-08 1.180406999999999962e-04 4.180000000000000000e+02 1.013164800000000102e-06 -4.400950200000000174e-07 9.540096899999999519e-03 4.185000000000000000e+02 4.549659999999999991e-07 -2.901131199999999839e-07 2.583802699999999865e-03 4.190000000000000000e+02 -1.760439299999999955e-07 -1.144702099999999994e-07 4.206719200000000216e-04 4.195000000000000000e+02 3.274771200000000000e-07 1.736090800000000020e-07 9.007285700000000530e-04 4.200000000000000000e+02 -8.905224699999999696e-07 2.674881000000000115e-07 4.836233799999999951e-03 4.205000000000000000e+02 -1.900399699999999835e-08 -9.625308600000000264e-07 9.546250100000000516e-03 4.210000000000000000e+02 1.178917800000000038e-06 -1.453830599999999995e-06 3.508572699999999711e-02 4.215000000000000000e+02 1.046848599999999984e-06 -8.636260999999999991e-07 1.670551899999999854e-02 4.220000000000000000e+02 7.545956500000000433e-07 1.438755799999999959e-07 5.405677900000000098e-03 4.225000000000000000e+02 -1.868788300000000074e-08 5.420002899999999496e-07 2.595371300000000065e-03 4.230000000000000000e+02 -2.513811800000000106e-07 -2.904132500000000015e-07 1.133171699999999896e-03 4.235000000000000000e+02 -1.205740999999999970e-07 -6.963413700000000467e-07 4.222005099999999629e-03 4.240000000000000000e+02 9.654654599999999711e-07 -7.550845599999999802e-07 1.301428500000000044e-02 4.245000000000000000e+02 5.471538899999999488e-07 -6.070325799999999920e-07 6.450292199999999899e-03 4.250000000000000000e+02 -8.977735899999999581e-09 -4.703937200000000133e-08 2.319916900000000163e-05 4.255000000000000000e+02 2.596949300000000079e-07 -1.592384400000000075e-08 6.888906900000000069e-04 4.260000000000000000e+02 6.162204600000000225e-07 1.675433300000000127e-07 3.425817900000000145e-03 4.265000000000000000e+02 -1.150409500000000048e-08 -5.545177299999999895e-07 2.715067900000000135e-03 4.270000000000000000e+02 -1.046872399999999921e-06 2.188100000000000118e-07 1.045108900000000021e-02 4.275000000000000000e+02 -3.837981700000000145e-08 4.004838300000000199e-07 1.604663899999999969e-03 4.280000000000000000e+02 9.686557400000001042e-07 3.967755300000000211e-07 8.992721299999999196e-03 4.285000000000000000e+02 4.400262700000000255e-07 3.194640500000000038e-07 2.155534199999999817e-03 4.290000000000000000e+02 -2.794432400000000199e-07 -1.066137700000000011e-06 6.201250900000000038e-03 4.295000000000000000e+02 1.331959400000000077e-08 -9.958743000000000173e-07 4.142456699999999895e-03 4.300000000000000000e+02 -1.030123600000000051e-07 -1.093071799999999945e-06 5.026787500000000179e-03 4.305000000000000000e+02 1.219404199999999910e-06 2.153327599999999896e-07 7.162498800000000054e-03 4.310000000000000000e+02 6.145696099999999916e-07 5.232994299999999778e-07 3.029048400000000033e-03 4.315000000000000000e+02 -1.210384400000000095e-07 7.982159799999999859e-07 3.670344099999999898e-03 4.320000000000000000e+02 3.018612900000000120e-08 5.200419099999999835e-07 1.352674899999999980e-03 4.325000000000000000e+02 1.801558800000000034e-07 5.450634100000000200e-07 1.755480000000000018e-03 4.330000000000000000e+02 4.068313000000000280e-08 5.815015199999999675e-07 2.130354799999999941e-03 4.335000000000000000e+02 5.702484599999999865e-07 -4.517397100000000007e-07 3.203737500000000075e-03 4.340000000000000000e+02 5.830381700000000436e-07 -1.485531399999999985e-07 2.370353099999999991e-03 4.345000000000000000e+02 -1.328314199999999950e-07 -3.778038700000000175e-07 1.137577099999999893e-03 4.350000000000000000e+02 7.990623800000000139e-07 -1.748554899999999905e-07 4.613630900000000382e-03 4.355000000000000000e+02 1.502819299999999955e-06 -1.740203400000000083e-07 1.540494199999999959e-02 4.360000000000000000e+02 1.550769899999999911e-06 4.147079599999999974e-07 1.718676099999999832e-02 4.365000000000000000e+02 9.130926099999999708e-07 1.061256500000000077e-06 1.315167499999999982e-02 4.370000000000000000e+02 7.433602599999999643e-09 9.352222000000000191e-07 6.163660900000000366e-03 4.375000000000000000e+02 4.987917399999999938e-07 -4.216924800000000091e-07 2.768901600000000032e-03 4.380000000000000000e+02 8.298466699999999736e-07 7.868518400000000388e-07 7.154252399999999970e-03 4.385000000000000000e+02 1.905572299999999909e-06 7.919376799999999846e-07 1.919049999999999923e-02 4.390000000000000000e+02 1.935872199999999917e-06 -8.772190099999999717e-07 2.069701100000000127e-02 4.395000000000000000e+02 7.674270299999999569e-07 -1.102474999999999977e-06 9.401024299999999681e-03 4.400000000000000000e+02 3.871401500000000257e-07 1.418840900000000073e-08 1.072375900000000068e-03 4.405000000000000000e+02 1.011794400000000009e-06 4.884815299999999821e-07 7.779684400000000388e-03 4.410000000000000000e+02 1.698032999999999943e-06 5.614182899999999981e-07 1.582154300000000041e-02 4.415000000000000000e+02 1.125911600000000035e-06 -7.678191300000000230e-07 9.328409100000000648e-03 4.420000000000000000e+02 1.153874099999999939e-06 -3.267640000000000003e-07 7.701374599999999751e-03 4.425000000000000000e+02 1.135554200000000069e-06 6.514489999999999990e-07 8.608090699999999471e-03 4.430000000000000000e+02 4.821286599999999997e-07 1.618565200000000026e-06 1.346296100000000072e-02 4.435000000000000000e+02 1.113332199999999911e-06 5.513901400000000474e-07 5.403623899999999633e-03 4.440000000000000000e+02 2.623359000000000085e-07 1.626715000000000018e-07 4.056890600000000158e-04 4.445000000000000000e+02 9.831874200000000690e-07 -3.578514100000000242e-07 5.167312500000000031e-03 4.450000000000000000e+02 1.086611200000000079e-06 -1.656513399999999947e-07 5.760983600000000107e-03 4.455000000000000000e+02 1.287387499999999920e-06 1.091101499999999958e-06 1.280958700000000075e-02 4.460000000000000000e+02 9.298990999999999997e-07 7.501977299999999523e-07 6.510294500000000407e-03 4.465000000000000000e+02 1.774148699999999931e-06 1.004922100000000022e-06 1.936456900000000161e-02 4.470000000000000000e+02 1.541122400000000102e-06 8.236830199999999712e-07 1.352503199999999933e-02 4.475000000000000000e+02 1.355037299999999936e-06 1.202963800000000093e-07 8.337289100000000799e-03 4.480000000000000000e+02 2.867869200000000186e-06 -7.606157500000000325e-08 3.567031400000000158e-02 4.485000000000000000e+02 2.708690299999999967e-06 1.200632300000000057e-06 3.449967500000000048e-02 4.490000000000000000e+02 7.095064800000000478e-07 1.307856000000000061e-06 7.733043299999999877e-03 4.495000000000000000e+02 2.057931399999999790e-06 3.250509099999999813e-07 1.456485199999999966e-02 4.500000000000000000e+02 7.643350300000000507e-07 7.443240699999999513e-08 2.302548800000000020e-03 4.505000000000000000e+02 9.100317599999999821e-07 8.301208800000000402e-07 5.821445500000000349e-03 4.510000000000000000e+02 1.553697200000000056e-06 5.054008600000000087e-07 9.274794700000000072e-03 4.515000000000000000e+02 2.448725600000000064e-06 5.315158699999999847e-07 2.306732300000000069e-02 4.520000000000000000e+02 2.777637699999999845e-06 9.908698100000000831e-07 2.875260300000000158e-02 4.525000000000000000e+02 2.377284999999999889e-06 5.697855299999999536e-07 1.569793400000000019e-02 4.530000000000000000e+02 2.338675999999999917e-06 1.084887099999999984e-06 1.484507900000000061e-02 4.535000000000000000e+02 2.440754299999999811e-06 1.932819900000000132e-06 2.632005899999999982e-02 4.540000000000000000e+02 1.722482399999999921e-06 1.803931499999999916e-06 1.826458099999999848e-02 4.545000000000000000e+02 2.107943400000000066e-06 1.113760600000000048e-06 1.626152000000000153e-02 4.550000000000000000e+02 9.024603900000000342e-07 -1.096171000000000029e-06 4.471803100000000357e-03 4.555000000000000000e+02 2.822306399999999989e-07 8.103121999999999944e-07 1.552168600000000025e-03 4.560000000000000000e+02 1.224515999999999899e-06 -5.468930199999999789e-08 3.242188100000000048e-03 4.565000000000000000e+02 1.745815000000000072e-06 -3.150383899999999771e-07 6.975750900000000053e-03 4.570000000000000000e+02 9.100595499999999933e-07 1.411819899999999954e-06 5.974730900000000018e-03 4.575000000000000000e+02 -3.809664100000000032e-07 3.392133899999999934e-07 5.555267599999999788e-04 4.580000000000000000e+02 2.414193000000000130e-06 -3.455036800000000251e-07 1.228537099999999979e-02 4.585000000000000000e+02 3.147990799999999845e-06 1.893992300000000013e-07 2.152075100000000116e-02 4.590000000000000000e+02 1.114430599999999907e-06 4.249921500000000129e-07 2.997026299999999959e-03 4.595000000000000000e+02 2.523529900000000106e-06 6.935094300000000177e-07 1.298348499999999947e-02 4.600000000000000000e+02 3.183091199999999910e-06 -9.961810300000001006e-07 2.227679999999999938e-02 4.605000000000000000e+02 1.336628699999999968e-06 -7.152361800000000041e-07 4.344061899999999629e-03 4.610000000000000000e+02 1.905765900000000001e-06 -2.321922800000000021e-07 7.651492999999999663e-03 4.615000000000000000e+02 1.716584099999999927e-06 3.410140700000000013e-07 5.957575500000000281e-03 4.620000000000000000e+02 2.649560200000000054e-06 9.078584100000000337e-07 1.301509799999999925e-02 4.625000000000000000e+02 1.996011900000000001e-06 4.171514500000000187e-07 7.562202399999999776e-03 4.630000000000000000e+02 4.235181699999999811e-06 -7.225809800000000104e-07 3.254724700000000137e-02 4.635000000000000000e+02 3.617305099999999944e-06 -2.859918600000000059e-06 3.499609599999999737e-02 4.640000000000000000e+02 3.526093899999999898e-06 -1.169046399999999914e-06 2.138536400000000046e-02 4.645000000000000000e+02 1.350815600000000101e-06 -5.032261999999999669e-07 3.138142599999999786e-03 4.650000000000000000e+02 1.381221900000000039e-06 1.713050500000000070e-07 2.686703300000000023e-03 4.655000000000000000e+02 2.700917100000000036e-06 9.938528399999999480e-07 1.021022700000000054e-02 4.660000000000000000e+02 4.395015400000000232e-06 1.529495900000000087e-06 2.384721500000000147e-02 4.665000000000000000e+02 4.108777399999999704e-06 5.443925500000000052e-07 1.757840399999999886e-02 4.670000000000000000e+02 3.725107299999999929e-06 8.971211399999999819e-07 1.462888799999999961e-02 4.675000000000000000e+02 3.946725399999999650e-06 -7.984146500000000468e-07 1.313482200000000086e-02 4.680000000000000000e+02 1.793079199999999969e-06 -3.787183199999999970e-06 1.149922899999999970e-02 4.685000000000000000e+02 1.653157600000000044e-06 -1.965408999999999941e-07 2.065046200000000137e-03 4.690000000000000000e+02 2.620607599999999988e-06 -1.066452499999999934e-06 5.359852699999999824e-03 4.695000000000000000e+02 2.249860199999999883e-06 -5.144520399999999927e-07 3.233514700000000072e-03 4.700000000000000000e+02 5.285344300000000217e-06 -1.709612700000000021e-06 1.969545099999999924e-02 4.705000000000000000e+02 4.851558500000000079e-06 -2.134006799999999915e-06 1.794043199999999921e-02 4.710000000000000000e+02 7.194741999999999800e-06 -1.068502000000000074e-06 3.094255400000000059e-02 4.715000000000000000e+02 7.517432100000000202e-06 6.851656700000000031e-07 1.941069399999999917e-02 4.720000000000000000e+02 2.429506400000000124e-06 -1.491291099999999922e-06 2.158529800000000016e-03 4.725000000000000000e+02 5.189460400000000381e-06 -3.131034599999999904e-06 1.599075499999999886e-02 4.730000000000000000e+02 1.697347700000000063e-06 2.451172600000000059e-06 4.580485599999999796e-03 4.735000000000000000e+02 -1.411653399999999963e-07 -2.459129299999999868e-06 3.044563299999999799e-03 4.740000000000000000e+02 1.083151500000000060e-05 -4.183115800000000374e-06 3.726315100000000130e-02 4.745000000000000000e+02 7.537604700000000159e-06 -2.564408999999999997e-06 1.423647400000000070e-02 4.750000000000000000e+02 2.840945899999999830e-06 -1.612990799999999930e-06 2.364814499999999976e-03 4.755000000000000000e+02 4.624117100000000105e-06 -7.581400000000000376e-07 4.428958099999999801e-03 4.760000000000000000e+02 1.047818499999999927e-06 4.930787999999999538e-07 3.418695700000000154e-04 4.765000000000000000e+02 2.511020499999999903e-07 -1.885199800000000088e-06 1.054734099999999914e-03 4.770000000000000000e+02 8.477098800000000001e-07 3.327698099999999804e-06 3.097381399999999882e-03 4.775000000000000000e+02 3.023702400000000186e-06 -4.626161599999999896e-07 2.183981199999999838e-03 4.780000000000000000e+02 2.302641200000000149e-06 -8.068785100000000309e-06 1.588947900000000149e-02 4.785000000000000000e+02 2.836069099999999975e-06 -7.073658700000000247e-06 1.239906900000000041e-02 4.790000000000000000e+02 -9.430029899999999541e-07 -8.259229599999999430e-06 1.815128300000000069e-02 4.795000000000000000e+02 -1.558509700000000021e-06 -3.473229300000000035e-06 5.797037399999999813e-03 4.800000000000000000e+02 -5.819024899999999798e-06 -2.872098799999999878e-06 2.167352999999999988e-02 4.805000000000000000e+02 -6.614257000000000224e-06 -1.772434200000000091e-07 1.931097700000000000e-02 4.810000000000000000e+02 -4.607886200000000301e-06 -2.149060299999999872e-06 9.638316900000000811e-03 4.815000000000000000e+02 -6.794061100000000441e-08 -5.480361800000000422e-06 1.160652199999999933e-02 4.820000000000000000e+02 -2.971952700000000034e-06 -9.858554200000000238e-07 5.201885899999999716e-03 4.825000000000000000e+02 -3.484545000000000025e-06 -8.884385399999999780e-07 1.035108199999999930e-02 4.830000000000000000e+02 5.455609699999999944e-07 -3.265714400000000064e-06 8.780592099999999858e-03 4.835000000000000000e+02 -1.385288799999999921e-06 -2.359682899999999843e-06 6.058850299999999842e-03 4.840000000000000000e+02 -2.313052199999999963e-07 -1.162850900000000102e-06 1.338835100000000059e-03 4.845000000000000000e+02 -4.975362900000000353e-07 -1.331341800000000080e-06 1.913498399999999941e-03 4.850000000000000000e+02 -7.239013900000000299e-07 -1.847024499999999997e-06 2.885596800000000094e-03 4.855000000000000000e+02 -6.841784699999999848e-08 -7.112448099999999863e-07 3.481139099999999882e-04 4.860000000000000000e+02 1.359482399999999966e-06 -2.070139099999999839e-06 3.961873200000000372e-03 4.865000000000000000e+02 1.425345999999999931e-06 9.723877399999999949e-07 2.212013399999999790e-03 4.870000000000000000e+02 -1.008776800000000103e-06 -2.850168800000000052e-07 8.714002299999999875e-04 4.875000000000000000e+02 1.423406800000000104e-06 -4.724006900000000044e-06 1.847237700000000163e-02 4.880000000000000000e+02 1.145558300000000023e-06 -3.111299699999999938e-06 9.144676799999999425e-03 4.885000000000000000e+02 -1.191096399999999982e-06 -1.052386800000000054e-06 2.078725999999999925e-03 4.890000000000000000e+02 1.643019899999999959e-06 -1.392658800000000072e-06 4.245756199999999904e-03 4.895000000000000000e+02 -5.550223799999999542e-07 -1.142272400000000101e-06 1.383271900000000026e-03 4.900000000000000000e+02 -1.505901499999999993e-06 -3.108723600000000042e-06 9.789605599999999172e-03 4.905000000000000000e+02 -1.239411900000000121e-07 -3.051009600000000192e-06 6.921468299999999733e-03 4.910000000000000000e+02 1.271163799999999976e-06 -1.843170799999999944e-06 2.936302699999999814e-03 4.915000000000000000e+02 8.896062700000000053e-07 -1.909277199999999962e-06 2.727872000000000109e-03 4.920000000000000000e+02 9.148739700000000404e-07 7.538446299999999398e-08 5.014035900000000110e-04 4.925000000000000000e+02 -1.837739300000000045e-06 -3.281271299999999898e-06 8.971958400000000500e-03 4.930000000000000000e+02 1.150018599999999921e-06 3.929799599999999764e-07 8.359811599999999749e-04 4.935000000000000000e+02 -2.031722499999999842e-06 -3.555825099999999899e-06 9.380694499999999922e-03 4.940000000000000000e+02 3.245025300000000144e-06 -2.942483699999999944e-06 9.241220499999999380e-03 4.945000000000000000e+02 -6.158135000000000291e-06 -1.989256800000000158e-06 1.694254200000000141e-02 4.950000000000000000e+02 1.104637100000000092e-06 -3.567430900000000210e-06 5.132699899999999989e-03 4.955000000000000000e+02 -3.533000899999999762e-07 -1.003149099999999997e-06 3.228801700000000240e-04 4.960000000000000000e+02 -7.891984499999999884e-07 -9.327450199999999826e-06 1.559749099999999979e-02 4.965000000000000000e+02 1.942185700000000022e-06 3.061597000000000174e-06 1.362370699999999922e-03 4.970000000000000000e+02 -1.442367800000000031e-06 -1.333953000000000034e-05 9.010173399999999930e-03 4.975000000000000000e+02 6.391840099999999714e-06 -5.286864499999999702e-06 1.654228900000000082e-03 4.980000000000000000e+02 -6.864371700000000128e-06 1.110299499999999990e-05 1.725286099999999954e-03 4.985000000000000000e+02 1.605744200000000136e-05 -3.131021699999999696e-05 4.123860499999999762e-03 4.990000000000000000e+02 -4.081000999999999791e-05 5.860602700000000151e-05 9.166674700000000328e-03 4.995000000000000000e+02 1.216645800000000060e-04 -7.608422300000000204e-05 1.300464599999999991e-02 5.000000000000000000e+02 -2.151357600000000051e-04 1.500425099999999927e-04 6.961547799999999626e-03 5.005000000000000000e+02 1.071906500000000028e-03 2.070889000000000020e-04 4.709771399999999886e-03 5.010000000000000000e+02 -1.767431700000000102e-03 -4.654407499999999899e-03 9.969854700000000021e-04 5.015000000000000000e+02 -3.066462500000000091e-02 -5.528716399999999975e-02 1.948323700000000047e-02 5.020000000000000000e+02 -1.446926999999999935e-02 -1.997997099999999915e-02 6.443751999999999640e-03 5.025000000000000000e+02 -1.327816299999999995e-03 4.609769700000000345e-03 6.678852699999999684e-03 5.030000000000000000e+02 -3.965987700000000267e-04 2.184036199999999945e-03 3.415043200000000053e-03 5.035000000000000000e+02 2.390976499999999943e-06 4.239409199999999932e-04 4.997918399999999768e-03 5.040000000000000000e+02 1.179810200000000023e-05 -6.714090700000000542e-05 4.308442000000000109e-04 5.045000000000000000e+02 -2.186712399999999972e-04 -7.181653099999999465e-04 1.317180499999999997e-03 5.050000000000000000e+02 -1.949690600000000005e-04 -1.474415300000000073e-03 4.285248900000000055e-03 5.055000000000000000e+02 -3.723541199999999877e-04 5.160935700000000197e-04 5.494926600000000008e-03 5.060000000000000000e+02 -1.629010399999999937e-04 1.396898599999999921e-03 8.012090799999999763e-03 5.065000000000000000e+02 1.356258699999999965e-04 1.065336699999999974e-04 1.716263900000000080e-03 5.070000000000000000e+02 -3.961985199999999859e-05 1.316808199999999892e-04 3.120815399999999793e-04 5.075000000000000000e+02 -9.535468999999999759e-04 2.508602599999999847e-04 2.100333600000000005e-03 5.080000000000000000e+02 -4.605363399999999933e-04 -1.257005299999999944e-03 8.460025400000000060e-04 5.085000000000000000e+02 -7.386498600000000010e-04 -1.549903100000000079e-03 1.762702500000000059e-03 5.090000000000000000e+02 1.129696700000000015e-04 2.157873199999999945e-04 1.067176699999999943e-04 5.095000000000000000e+02 3.245548599999999889e-04 1.252830999999999932e-04 1.578164099999999903e-02 5.100000000000000000e+02 -4.320638300000000039e-05 -2.171608999999999963e-05 8.379884100000000238e-03