############################################################ ############################################################ ### NEW CALIBRATION EPICS "WRITE" MATLAB LOG ### ### 29-Sep-2015 10:59:03 ### ############################################################ ############################################################ # DARM parameter file: H1DARMparams_1125963332.m ############################################################ ### MODEL VALUES FOR CAL LINE at f_tst = 35.9 Hz ### ############################################################ Re{ C_0(35.9) } = 1.10159e+06 Im{ C_0(35.9) } = -162598 Re{ C_{res}(35.9) } = 1.1187e+06 Im{ C_{res}(35.9) } = -46624.5 Re{ D_0(35.9) } = 7.24018e+09 Im{ D_0(35.9) } = 1.44004e+10 Re{ A_0^{tst}(35.9) } = -8.84658e-19 Im{ A_0^{tst}(35.9) } = -4.61252e-17 Re{ A_0^{pum}(35.9) } = -1.54169e-17 Im{ A_0^{pum}(35.9) } = 4.99024e-17 Re{ A_0^{uim}(35.9) } = -2.06481e-20 Im{ A_0^{uim}(35.9) } = -5.40844e-21 Re{ A_0^{top}(35.9) } = 0 Im{ A_0^{top}(35.9) } = 0 Re{ G_0(35.9) } = -0.853278 Im{ G_0(35.9) } = -0.758468 CALCULATED VALUES FOR CAL LINE at f_tst = 35.9 Hz: Re{ A_0^{p/u}(35.9) } = -1.54375e-17 Im{ A_0^{p/u}(35.9) } = 4.9897e-17 | A_0^{tst}(35.9) |^2 = 2.12832e-33 Re{ - 1 / A_0^{tst}(35.9) } = 4.1566e+14 Im{ - 1 / A_0^{tst}(35.9) } = -2.16721e+16 Re{ (1 + G_0(35.9)) / C_0(35.9) } = 2.29813e-07 Im{ (1 + G_0(35.9)) / C_0(35.9) } = -6.54602e-07 ############################################################ ### MODEL VALUES FOR CAL LINE at f_pcal = 36.7 Hz ### ############################################################ Re{ C_0(36.7) } = 1.10082e+06 Im{ C_0(36.7) } = -166372 Re{ C_{res}(36.7) } = 1.11872e+06 Im{ C_{res}(36.7) } = -47896.6 Re{ D_0(36.7) } = 7.33025e+09 Im{ D_0(36.7) } = 1.47819e+10 Re{ A_0^{tst}(36.7) } = -4.5357e-17 Im{ A_0^{tst}(36.7) } = -3.34952e-17 Re{ A_0^{pum}(36.7) } = -1.36657e-17 Im{ A_0^{pum}(36.7) } = 4.74395e-17 Re{ A_0^{uim}(36.7) } = -1.8175e-20 Im{ A_0^{uim}(36.7) } = -4.42161e-21 Re{ A_0^{top}(36.7) } = 0 Im{ A_0^{top}(36.7) } = 0 Re{ G_0(36.7) } = -0.831447 Im{ G_0(36.7) } = -0.741955 CALCULATED VALUES FOR CAL LINE at f_pcal = 36.7 Hz: Re{ A_0^{p/u}(36.7) } = -1.36839e-17 Im{ A_0^{p/u}(36.7) } = 4.74351e-17 | A_0^{tst}(36.7) |^2 = 3.17918e-33 Re{ - 1 / A_0^{tst}(36.7) } = 1.42669e+16 Im{ - 1 / A_0^{tst}(36.7) } = -1.05358e+16 Re{ (1 + G_0(36.7)) / C_0(36.7) } = 2.49288e-07 Im{ (1 + G_0(36.7)) / C_0(36.7) } = -6.36328e-07 ############################################################ ### MODEL VALUES FOR CAL LINE at f_ctrl = 37.3 Hz ### ############################################################ Re{ C_0(37.3) } = 1.10022e+06 Im{ C_0(37.3) } = -169195 Re{ C_{res}(37.3) } = 1.11873e+06 Im{ C_{res}(37.3) } = -48848.5 Re{ D_0(37.3) } = 7.3987e+09 Im{ D_0(37.3) } = 1.5067e+10 Re{ A_0^{tst}(37.3) } = -4.45405e-17 Im{ A_0^{tst}(37.3) } = -3.22197e-17 Re{ A_0^{pum}(37.3) } = -1.24621e-17 Im{ A_0^{pum}(37.3) } = 4.569e-17 Re{ A_0^{uim}(37.3) } = -1.65433e-20 Im{ A_0^{uim}(37.3) } = -3.80162e-21 Re{ A_0^{top}(37.3) } = 0 Im{ A_0^{top}(37.3) } = 0 Re{ G_0(37.3) } = -0.815883 Im{ G_0(37.3) } = -0.72988 Re{ 1 / A_0^{pu}(37.3) } = -5.56352e+15 Im{ 1 / A_0^{pu}(37.3) } = -2.03688e+16 CALCULATED VALUES FOR CAL LINE at f_ctrl = 37.3 Hz: Re{ A_0^{p/u}(37.3) } = -1.24787e-17 Im{ A_0^{p/u}(37.3) } = 4.56862e-17 | A_0^{tst}(37.3) |^2 = 3.02196e-33 Re{ - 1 / A_0^{tst}(37.3) } = 1.47389e+16 Im{ - 1 / A_0^{tst}(37.3) } = -1.06619e+16 Re{ (1 + G_0(37.3)) / C_0(37.3) } = 2.63141e-07 Im{ (1 + G_0(37.3)) / C_0(37.3) } = -6.22927e-07 ############################################################ ### MODEL VALUES FOR CAL LINE at f_pcal2 = 331.9 Hz ### ############################################################ Re{ C_0(331.9) } = 290585 Im{ C_0(331.9) } = -756394 Re{ C_{res}(331.9) } = 1.02679e+06 Im{ C_{res}(331.9) } = -473564 Re{ D_0(331.9) } = 1.66411e+07 Im{ D_0(331.9) } = 5.72814e+06 Re{ A_0^{tst}(331.9) } = -1.17934e-18 Im{ A_0^{tst}(331.9) } = 3.03633e-19 Re{ A_0^{pum}(331.9) } = -1.66596e-19 Im{ A_0^{pum}(331.9) } = -1.26166e-19 Re{ A_0^{uim}(331.9) } = 3.01083e-26 Im{ A_0^{uim}(331.9) } = 3.43411e-26 Re{ A_0^{top}(331.9) } = 0 Im{ A_0^{top}(331.9) } = 0 Re{ G_0(331.9) } = -1.04016e-05 Im{ G_0(331.9) } = 1.63283e-05 CALCULATED VALUES FOR CAL LINE at f_pcal2 = 331.9 Hz: Re{ A_0^{p/u}(331.9) } = -1.66595e-19 Im{ A_0^{p/u}(331.9) } = -1.26166e-19 | A_0^{tst}(331.9) |^2 = 1.48303e-36 Re{ - 1 / A_0^{tst}(331.9) } = 7.95222e+17 Im{ - 1 / A_0^{tst}(331.9) } = 2.04738e+17 Re{ (1 + G_0(331.9)) / C_0(331.9) } = 4.42555e-07 Im{ (1 + G_0(331.9)) / C_0(331.9) } = 1.15203e-06 !!! SKIPPING CAL LINE at f_pcal3 = 1083.7 Hz, NO INSTANCE WAS SET FOR THE CHANNEL !!! !!! SKIPPING CAL LINE at f_pcal4 = 3001.3 Hz, NO INSTANCE WAS SET FOR THE CHANNEL !!! ############################################################ ### MODEL VALUES FROM COMBINATION OF CAL LINES ### ############################################################ Re{ R_tst } = Re{ (C_0(f_pcal) / (1 + G_0(f_pcal))) * (C_0(f_tst) / (1 + G_0(f_tst)))^{-1} } = 1.0145 Im{ R_tst } = Im{ (C_0(f_pcal) / (1 + G_0(f_pcal))) * (C_0(f_tst) / (1 + G_0(f_tst)))^{-1} } = -0.0362863 Re{ (- 1 / A_0^tst(f_tst)) * (C_0(f_pcal) / (1 + G_0(f_pcal))) * (C_0(f_tst) / (1 + G_0(f_tst)))^{-1} } = 3.64714e+14 Im{ (- 1 / A_0^tst(f_tst)) * (C_0(f_pcal) / (1 + G_0(f_pcal))) * (C_0(f_tst) / (1 + G_0(f_tst)))^{-1} } = 2.20015e+16 Re{ R_ctrl } = Re{ (C_0(f_pcal) / (1 + G_0(f_pcal))) * (C_0(f_ctrl) / (1 + G_0(f_ctrl)))^{-1} } = 0.988661 Im{ R_ctrl } = Im{ (C_0(f_pcal) / (1 + G_0(f_pcal))) * (C_0(f_ctrl) / (1 + G_0(f_ctrl)))^{-1} } = 0.0401723 ############################################################ ### WRITING INTO EPICS ### ############################################################ Old : H1:CAL-CS_TDEP_ESD_LINE1_REF_C_REAL 1.10107e+06 New : H1:CAL-CS_TDEP_ESD_LINE1_REF_C_REAL 1.10159e+06 Old : H1:CAL-CS_TDEP_ESD_LINE1_REF_C_IMAG -166076 New : H1:CAL-CS_TDEP_ESD_LINE1_REF_C_IMAG -162598 Old : H1:CAL-CS_TDEP_ESD_LINE1_REF_C_NOCAVPOLE_REAL 1.11855e+06 New : H1:CAL-CS_TDEP_ESD_LINE1_REF_C_NOCAVPOLE_REAL 1.1187e+06 Old : H1:CAL-CS_TDEP_ESD_LINE1_REF_C_NOCAVPOLE_IMAG -50157 New : H1:CAL-CS_TDEP_ESD_LINE1_REF_C_NOCAVPOLE_IMAG -46624.5 Old : H1:CAL-CS_TDEP_ESD_LINE1_REF_D_REAL 7.24018e+09 New : H1:CAL-CS_TDEP_ESD_LINE1_REF_D_REAL 7.24018e+09 Old : H1:CAL-CS_TDEP_ESD_LINE1_REF_D_IMAG 1.44004e+10 New : H1:CAL-CS_TDEP_ESD_LINE1_REF_D_IMAG 1.44004e+10 Old : H1:CAL-CS_TDEP_ESD_LINE1_REF_A_TST_REAL 3.8093e-18 New : H1:CAL-CS_TDEP_ESD_LINE1_REF_A_TST_REAL -8.84658e-19 Old : H1:CAL-CS_TDEP_ESD_LINE1_REF_A_TST_IMAG 4.68963e-17 New : H1:CAL-CS_TDEP_ESD_LINE1_REF_A_TST_IMAG -4.61252e-17 Old : H1:CAL-CS_TDEP_ESD_LINE1_REF_A_PUM_REAL -1.58295e-17 New : H1:CAL-CS_TDEP_ESD_LINE1_REF_A_PUM_REAL -1.54169e-17 Old : H1:CAL-CS_TDEP_ESD_LINE1_REF_A_PUM_IMAG 5.03122e-17 New : H1:CAL-CS_TDEP_ESD_LINE1_REF_A_PUM_IMAG 4.99024e-17 Old : H1:CAL-CS_TDEP_ESD_LINE1_REF_A_UIM_REAL -2.08227e-20 New : H1:CAL-CS_TDEP_ESD_LINE1_REF_A_UIM_REAL -2.06481e-20 Old : H1:CAL-CS_TDEP_ESD_LINE1_REF_A_UIM_IMAG -5.56965e-21 New : H1:CAL-CS_TDEP_ESD_LINE1_REF_A_UIM_IMAG -5.40844e-21 Old : H1:CAL-CS_TDEP_ESD_LINE1_REF_A_TOP_REAL 0 New : H1:CAL-CS_TDEP_ESD_LINE1_REF_A_TOP_REAL 0 Old : H1:CAL-CS_TDEP_ESD_LINE1_REF_A_TOP_IMAG 0 New : H1:CAL-CS_TDEP_ESD_LINE1_REF_A_TOP_IMAG 0 Old : H1:CAL-CS_TDEP_ESD_LINE1_REF_OLG_REAL -0.860124 New : H1:CAL-CS_TDEP_ESD_LINE1_REF_OLG_REAL -0.853278 Old : H1:CAL-CS_TDEP_ESD_LINE1_REF_OLG_IMAG -0.767675 New : H1:CAL-CS_TDEP_ESD_LINE1_REF_OLG_IMAG -0.758468 Old : H1:CAL-CS_TDEP_PCALY_LINE1_REF_C_REAL 1.10027e+06 New : H1:CAL-CS_TDEP_PCALY_LINE1_REF_C_REAL 1.10082e+06 Old : H1:CAL-CS_TDEP_PCALY_LINE1_REF_C_IMAG -169924 New : H1:CAL-CS_TDEP_PCALY_LINE1_REF_C_IMAG -166372 Old : H1:CAL-CS_TDEP_PCALY_LINE1_REF_C_NOCAVPOLE_REAL 1.11856e+06 New : H1:CAL-CS_TDEP_PCALY_LINE1_REF_C_NOCAVPOLE_REAL 1.11872e+06 Old : H1:CAL-CS_TDEP_PCALY_LINE1_REF_C_NOCAVPOLE_IMAG -51508 New : H1:CAL-CS_TDEP_PCALY_LINE1_REF_C_NOCAVPOLE_IMAG -47896.6 Old : H1:CAL-CS_TDEP_PCALY_LINE1_REF_D_REAL 7.33025e+09 New : H1:CAL-CS_TDEP_PCALY_LINE1_REF_D_REAL 7.33025e+09 Old : H1:CAL-CS_TDEP_PCALY_LINE1_REF_D_IMAG 1.47819e+10 New : H1:CAL-CS_TDEP_PCALY_LINE1_REF_D_IMAG 1.47819e+10 Old : H1:CAL-CS_TDEP_PCALY_LINE1_REF_A_TST_REAL -4.56236e-17 New : H1:CAL-CS_TDEP_PCALY_LINE1_REF_A_TST_REAL -4.5357e-17 Old : H1:CAL-CS_TDEP_PCALY_LINE1_REF_A_TST_IMAG -3.4067e-17 New : H1:CAL-CS_TDEP_PCALY_LINE1_REF_A_TST_IMAG -3.34952e-17 Old : H1:CAL-CS_TDEP_PCALY_LINE1_REF_A_PUM_REAL -1.40538e-17 New : H1:CAL-CS_TDEP_PCALY_LINE1_REF_A_PUM_REAL -1.36657e-17 Old : H1:CAL-CS_TDEP_PCALY_LINE1_REF_A_PUM_IMAG 4.78326e-17 New : H1:CAL-CS_TDEP_PCALY_LINE1_REF_A_PUM_IMAG 4.74395e-17 Old : H1:CAL-CS_TDEP_PCALY_LINE1_REF_A_UIM_REAL -1.833e-20 New : H1:CAL-CS_TDEP_PCALY_LINE1_REF_A_UIM_REAL -1.8175e-20 Old : H1:CAL-CS_TDEP_PCALY_LINE1_REF_A_UIM_IMAG -4.56229e-21 New : H1:CAL-CS_TDEP_PCALY_LINE1_REF_A_UIM_IMAG -4.42161e-21 Old : H1:CAL-CS_TDEP_PCALY_LINE1_REF_A_TOP_REAL 0 New : H1:CAL-CS_TDEP_PCALY_LINE1_REF_A_TOP_REAL 0 Old : H1:CAL-CS_TDEP_PCALY_LINE1_REF_A_TOP_IMAG 0 New : H1:CAL-CS_TDEP_PCALY_LINE1_REF_A_TOP_IMAG 0 Old : H1:CAL-CS_TDEP_PCALY_LINE1_REF_OLG_REAL -0.838078 New : H1:CAL-CS_TDEP_PCALY_LINE1_REF_OLG_REAL -0.831447 Old : H1:CAL-CS_TDEP_PCALY_LINE1_REF_OLG_IMAG -0.750993 New : H1:CAL-CS_TDEP_PCALY_LINE1_REF_OLG_IMAG -0.741955 Old : H1:CAL-CS_TDEP_DARM_LINE1_REF_C_REAL 1.09966e+06 New : H1:CAL-CS_TDEP_DARM_LINE1_REF_C_REAL 1.10022e+06 Old : H1:CAL-CS_TDEP_DARM_LINE1_REF_C_IMAG -172804 New : H1:CAL-CS_TDEP_DARM_LINE1_REF_C_IMAG -169195 Old : H1:CAL-CS_TDEP_DARM_LINE1_REF_C_NOCAVPOLE_REAL 1.11856e+06 New : H1:CAL-CS_TDEP_DARM_LINE1_REF_C_NOCAVPOLE_REAL 1.11873e+06 Old : H1:CAL-CS_TDEP_DARM_LINE1_REF_C_NOCAVPOLE_IMAG -52518.8 New : H1:CAL-CS_TDEP_DARM_LINE1_REF_C_NOCAVPOLE_IMAG -48848.5 Old : H1:CAL-CS_TDEP_DARM_LINE1_REF_D_REAL 7.3987e+09 New : H1:CAL-CS_TDEP_DARM_LINE1_REF_D_REAL 7.3987e+09 Old : H1:CAL-CS_TDEP_DARM_LINE1_REF_D_IMAG 1.5067e+10 New : H1:CAL-CS_TDEP_DARM_LINE1_REF_D_IMAG 1.5067e+10 Old : H1:CAL-CS_TDEP_DARM_LINE1_REF_A_TST_REAL -4.4803e-17 New : H1:CAL-CS_TDEP_DARM_LINE1_REF_A_TST_REAL -4.45405e-17 Old : H1:CAL-CS_TDEP_DARM_LINE1_REF_A_TST_IMAG -3.27785e-17 New : H1:CAL-CS_TDEP_DARM_LINE1_REF_A_TST_IMAG -3.22197e-17 Old : H1:CAL-CS_TDEP_DARM_LINE1_REF_A_PUM_REAL -1.2833e-17 New : H1:CAL-CS_TDEP_DARM_LINE1_REF_A_PUM_REAL -1.24621e-17 Old : H1:CAL-CS_TDEP_DARM_LINE1_REF_A_PUM_IMAG 4.60713e-17 New : H1:CAL-CS_TDEP_DARM_LINE1_REF_A_PUM_IMAG 4.569e-17 Old : H1:CAL-CS_TDEP_DARM_LINE1_REF_A_UIM_REAL -1.66852e-20 New : H1:CAL-CS_TDEP_DARM_LINE1_REF_A_UIM_REAL -1.65433e-20 Old : H1:CAL-CS_TDEP_DARM_LINE1_REF_A_UIM_IMAG -3.92893e-21 New : H1:CAL-CS_TDEP_DARM_LINE1_REF_A_UIM_IMAG -3.80162e-21 Old : H1:CAL-CS_TDEP_DARM_LINE1_REF_A_TOP_REAL 0 New : H1:CAL-CS_TDEP_DARM_LINE1_REF_A_TOP_REAL 0 Old : H1:CAL-CS_TDEP_DARM_LINE1_REF_A_TOP_IMAG 0 New : H1:CAL-CS_TDEP_DARM_LINE1_REF_A_TOP_IMAG 0 Old : H1:CAL-CS_TDEP_DARM_LINE1_REF_OLG_REAL -0.822362 New : H1:CAL-CS_TDEP_DARM_LINE1_REF_OLG_REAL -0.815883 Old : H1:CAL-CS_TDEP_DARM_LINE1_REF_OLG_IMAG -0.738795 New : H1:CAL-CS_TDEP_DARM_LINE1_REF_OLG_IMAG -0.72988 Old : H1:CAL-CS_TDEP_DARM_LINE1_REF_A_USUM_INV_REAL -5.61781e+15 New : H1:CAL-CS_TDEP_DARM_LINE1_REF_A_USUM_INV_REAL -5.56352e+15 Old : H1:CAL-CS_TDEP_DARM_LINE1_REF_A_USUM_INV_IMAG -2.01403e+16 New : H1:CAL-CS_TDEP_DARM_LINE1_REF_A_USUM_INV_IMAG -2.03688e+16 Old : H1:CAL-CS_TDEP_PCALY_LINE2_REF_C_REAL 268381 New : H1:CAL-CS_TDEP_PCALY_LINE2_REF_C_REAL 290585 Old : H1:CAL-CS_TDEP_PCALY_LINE2_REF_C_IMAG -764555 New : H1:CAL-CS_TDEP_PCALY_LINE2_REF_C_IMAG -756394 Old : H1:CAL-CS_TDEP_PCALY_LINE2_REF_C_NOCAVPOLE_REAL 1.01253e+06 New : H1:CAL-CS_TDEP_PCALY_LINE2_REF_C_NOCAVPOLE_REAL 1.02679e+06 Old : H1:CAL-CS_TDEP_PCALY_LINE2_REF_C_NOCAVPOLE_IMAG -503336 New : H1:CAL-CS_TDEP_PCALY_LINE2_REF_C_NOCAVPOLE_IMAG -473564 Old : H1:CAL-CS_TDEP_PCALY_LINE2_REF_D_REAL 1.66411e+07 New : H1:CAL-CS_TDEP_PCALY_LINE2_REF_D_REAL 1.66411e+07 Old : H1:CAL-CS_TDEP_PCALY_LINE2_REF_D_IMAG 5.72814e+06 New : H1:CAL-CS_TDEP_PCALY_LINE2_REF_D_IMAG 5.72814e+06 Old : H1:CAL-CS_TDEP_PCALY_LINE2_REF_A_TST_REAL -1.20475e-18 New : H1:CAL-CS_TDEP_PCALY_LINE2_REF_A_TST_REAL -1.17934e-18 Old : H1:CAL-CS_TDEP_PCALY_LINE2_REF_A_TST_IMAG 2.49349e-19 New : H1:CAL-CS_TDEP_PCALY_LINE2_REF_A_TST_IMAG 3.03633e-19 Old : H1:CAL-CS_TDEP_PCALY_LINE2_REF_A_PUM_REAL -1.62008e-19 New : H1:CAL-CS_TDEP_PCALY_LINE2_REF_A_PUM_REAL -1.66596e-19 Old : H1:CAL-CS_TDEP_PCALY_LINE2_REF_A_PUM_IMAG -1.35372e-19 New : H1:CAL-CS_TDEP_PCALY_LINE2_REF_A_PUM_IMAG -1.26166e-19 Old : H1:CAL-CS_TDEP_PCALY_LINE2_REF_A_UIM_REAL 2.87211e-26 New : H1:CAL-CS_TDEP_PCALY_LINE2_REF_A_UIM_REAL 3.01083e-26 Old : H1:CAL-CS_TDEP_PCALY_LINE2_REF_A_UIM_IMAG 3.61099e-26 New : H1:CAL-CS_TDEP_PCALY_LINE2_REF_A_UIM_IMAG 3.43411e-26 Old : H1:CAL-CS_TDEP_PCALY_LINE2_REF_A_TOP_REAL 0 New : H1:CAL-CS_TDEP_PCALY_LINE2_REF_A_TOP_REAL 0 Old : H1:CAL-CS_TDEP_PCALY_LINE2_REF_A_TOP_IMAG 0 New : H1:CAL-CS_TDEP_PCALY_LINE2_REF_A_TOP_IMAG 0 Old : H1:CAL-CS_TDEP_PCALY_LINE2_REF_OLG_REAL -1.08149e-05 New : H1:CAL-CS_TDEP_PCALY_LINE2_REF_OLG_REAL -1.04016e-05 Old : H1:CAL-CS_TDEP_PCALY_LINE2_REF_OLG_IMAG 1.62964e-05 New : H1:CAL-CS_TDEP_PCALY_LINE2_REF_OLG_IMAG 1.63283e-05 Old : H1:CAL-CS_TDEP_REF_INVA_CLGRATIO_TST_REAL -9.79465e+14 New : H1:CAL-CS_TDEP_REF_INVA_CLGRATIO_TST_REAL 3.64714e+14 Old : H1:CAL-CS_TDEP_REF_INVA_CLGRATIO_TST_IMAG 2.15612e+16 New : H1:CAL-CS_TDEP_REF_INVA_CLGRATIO_TST_IMAG 2.20015e+16 Old : H1:CAL-CS_TDEP_REF_CLGRATIO_CTRL_REAL 0.988396 New : H1:CAL-CS_TDEP_REF_CLGRATIO_CTRL_REAL 0.988661 Old : H1:CAL-CS_TDEP_REF_CLGRATIO_CTRL_IMAG 0.0401016 New : H1:CAL-CS_TDEP_REF_CLGRATIO_CTRL_IMAG 0.0401723 ############################################################ ### END OF LOG (START TIME: 29-Sep-2015 10:59:03) ### ############################################################