---- HARDWARE INJECTION REPORT ---- #--------------------------------------------------------------------------------# Report of all hardware injections in the Hanford and Livingston IFOs. For all injection tables, we have the following definitions concerning the frame flags field (FrFlags): Frame flags are specified in the following order, from left to right in the field: 1. CAL-INJ TRANSIENT injection bit (CAL-INJ channel in RAW frames) 2. CAL-INJ channel in RAW frames 3. ODC-MASTER channel in HOFT frames 4. ODC-MASTER channel in RAW frames 5. ODC-MASTER channel in RDS frames 6. GDS-CALIB channeld in HOFT frames Frame flag symbols have the following meaning: 'X' = injection found to occur '0' = injection not found to occur '-' = frame channel or bit not checked. #--------------------------------------------------------------------------------# GPS Start Time = 1131828057 # Beginning of time span, in GPS seconds, to search for injections GPS End Time = 1132088085 # Ending of time span, in GPS seconds, to search for injections Check Hanford IFO = True # Check for injections in the Hanford IFO frame files. Check Livingston IFO = True # Check for injections in the Livingston IFO frame files. IFO Coinc Time = 0.012 # Time window, in seconds, for coincidence between IFO injection events. Check ODC_HOFT = True # Check ODC-MASTER_CHANNEL_OUT_DQ channel in HOFT frames. Check ODC_RAW = True # Check ODC-MASTER_CHANNEL_OUT_DQ channel in RAW frames. Check ODC_RDS = True # Check ODC-MASTER_CHANNEL_OUT_DQ channel in RDS frames. Check GDS_HOFT = True # Check GDS-CALIB_STATE_VECTOR channel in HOFT frames. Check CAL_RAW = True # Check CAL-INJ_ODC_CHANNEL_OUT_DQ channel in RAW frames. Report Normal = True # Include normal (IFO-coincident (network injections only), consistent, scheduled, and of known type) injections in report Report Anomalous = True # Include anomalous (non-IFO-coincident (network injections only), inconsistent, unscheduled, or of unknown type) injections in report Use CONDOR optimizations = True # Enable optimizations that assume execution on a CONDOR machine #--------------------------------------------------------------------------------# # --- Table 0:Occurring Schedule Injs --- # Table of scheduled injections that were found to occur in at least 1 IFO. | Inj UID | Inj Name | Inj Type | GPS Time | Amp Scale | - --------- ---------------------------------- ---------- ------------------ ------------ - # --- end Table 0:Occurring Schedule Injs --- # # --- Table 1:Non-occurring Schedule Injs --- # Table of scheduled injections that did not occur in any IFO. | Inj UID | Inj Name | Inj Type | GPS Time | Amp Scale | - --------- ---------------------------------- ---------- ------------------ ------------ - # --- end Table 1:Non-occurring Schedule Injs --- # # --- Table 2:Normal Network Injs --- # Table of IFO-coincident, consistent, scheduled, and known type network injections. | Inj UID | Inj Name | Inj Type | H1 UID | H1 Type | H1 GPS Time | H1 FrFlags | L1 UID | L1 Type | L1 GPS Time | L1 FrFlags | - --------- ---------------------------------- ---------- -------- ---------- ------------------ ------------ -------- ---------- ------------------ ------------ - # --- end Table 2:Normal Network Injs --- # # --- Table 3:Anomalous Network Injs --- # Table of non-IFO-coincident, inconsistent, unscheduled, or unknown type network injections. | Inj UID | Inj Name | Inj Type | H1 UID | H1 Type | H1 GPS Time | H1 FrFlags | L1 UID | L1 Type | L1 GPS Time | L1 FrFlags | - --------- ---------------------------------- ---------- -------- ---------- ------------------ ------------ -------- ---------- ------------------ ------------ - | - | UNSCHEDULED | CALRESET | - | CALRESET | 1131831157.000 | 00X00X | - | - | - | - | | - | UNSCHEDULED | CALRESET | - | CALRESET | 1131843394.000 | 00X00X | - | - | - | - | # --- end Table 3:Anomalous Network Injs --- # # --- Table 4:H1 IFO Injs --- # Table of all H1 IFO injections. | Inj UID | Inj Name | Inj Type | GPS Time | FrFlags | - --------- ---------------------------------- ---------- ------------------ ------------ - | - | UNSCHEDULED | CALRESET | 1131831157.000 | 00X00X | | - | UNSCHEDULED | CALRESET | 1131843394.000 | 00X00X | # --- end Table 4:H1 IFO Injs --- # # --- Table 5:H1-only IFO Injs --- # Table of all H1-only IFO injections. | Inj UID | Inj Name | Inj Type | GPS Time | FrFlags | - --------- ---------------------------------- ---------- ------------------ ------------ - | - | UNSCHEDULED | CALRESET | 1131831157.000 | 00X00X | | - | UNSCHEDULED | CALRESET | 1131843394.000 | 00X00X | # --- end Table 5:H1-only IFO Injs --- # # --- Table 6:L1 IFO Injs --- # Table of all L1 IFO injections. | Inj UID | Inj Name | Inj Type | GPS Time | FrFlags | - --------- ---------------------------------- ---------- ------------------ ------------ - # --- end Table 6:L1 IFO Injs --- # # --- Table 7:L1-only IFO Injs --- # Table of all L1-only IFO injections. | Inj UID | Inj Name | Inj Type | GPS Time | FrFlags | - --------- ---------------------------------- ---------- ------------------ ------------ - # --- end Table 7:L1-only IFO Injs --- # #---------------------------------- END REPORT ----------------------------------#