---- HARDWARE INJECTION REPORT ---- #--------------------------------------------------------------------------------# Report of all hardware injections in the Hanford and Livingston IFOs. For all injection tables, we have the following definitions concerning the frame flags field (FrFlags): Frame flags are specified in the following order, from left to right in the field: 1. CAL-INJ TRANSIENT injection bit (CAL-INJ channel in RAW frames) 2. CAL-INJ channel in RAW frames 3. ODC-MASTER channel in HOFT frames 4. ODC-MASTER channel in RAW frames 5. ODC-MASTER channel in RDS frames 6. GDS-CALIB channeld in HOFT frames Frame flag symbols have the following meaning: 'X' = injection found to occur '0' = injection not found to occur '-' = frame channel or bit not checked. #--------------------------------------------------------------------------------# GPS Start Time = 1132963217 # Beginning of time span, in GPS seconds, to search for injections GPS End Time = 1136155727 # Ending of time span, in GPS seconds, to search for injections Check Hanford IFO = True # Check for injections in the Hanford IFO frame files. Check Livingston IFO = True # Check for injections in the Livingston IFO frame files. IFO Coinc Time = 0.012 # Time window, in seconds, for coincidence between IFO injection events. Check ODC_HOFT = True # Check ODC-MASTER_CHANNEL_OUT_DQ channel in HOFT frames. Check ODC_RAW = True # Check ODC-MASTER_CHANNEL_OUT_DQ channel in RAW frames. Check ODC_RDS = True # Check ODC-MASTER_CHANNEL_OUT_DQ channel in RDS frames. Check GDS_HOFT = True # Check GDS-CALIB_STATE_VECTOR channel in HOFT frames. Check CAL_RAW = True # Check CAL-INJ_ODC_CHANNEL_OUT_DQ channel in RAW frames. Report Normal = True # Include normal (IFO-coincident (network injections only), consistent, scheduled, and of known type) injections in report Report Anomalous = True # Include anomalous (non-IFO-coincident (network injections only), inconsistent, unscheduled, or of unknown type) injections in report Use CONDOR optimizations = True # Enable optimizations that assume execution on a CONDOR machine #--------------------------------------------------------------------------------# # --- Table 0:Occurring Schedule Injs --- # Table of scheduled injections that were found to occur in at least 1 IFO. | Inj UID | Inj Name | Inj Type | GPS Time | Amp Scale | - --------- ---------------------------------- ---------- ------------------ ------------ - | 0 | coherentbbh10_1128678894_ | CBC | 1134345924.000 | 1.000000 | | 1 | coherentbbh11_1128678894_ | CBC | 1134348928.000 | 1.000000 | | 2 | coherentbbh15_1128678894_ | CBC | 1134353728.000 | 1.000000 | | 3 | coherentbbh16_1128678894_ | CBC | 1134354928.000 | 1.000000 | | 4 | coherentbbh17_1128678894_ | CBC | 1134356128.000 | 1.000000 | | 5 | coherentbbh18_1128678894_ | CBC | 1134357328.000 | 1.000000 | | 6 | coherentbbh11_1128678894_ | CBC | 1134359800.000 | 1.000000 | | 7 | coherentbbh12_1128678894_ | CBC | 1134361000.000 | 1.000000 | | 8 | coherentbbh13_1128678894_ | CBC | 1134362200.000 | 1.000000 | | 9 | coherentbbh14_1128678894_ | CBC | 1134363400.000 | 1.000000 | | 10 | coherentbbh19_1128678894_ | CBC | 1134364600.000 | 1.000000 | | 12 | WNB_burst_1134573920_1_ | BURST | 1134581196.000 | 1.000000 | # --- end Table 0:Occurring Schedule Injs --- # # --- Table 1:Non-occurring Schedule Injs --- # Table of scheduled injections that did not occur in any IFO. | Inj UID | Inj Name | Inj Type | GPS Time | Amp Scale | - --------- ---------------------------------- ---------- ------------------ ------------ - | 11 | WNB_burst_1134573920_1_ | BURST | 1134577813.000 | 1.000000 | # --- end Table 1:Non-occurring Schedule Injs --- # # --- Table 2:Normal Network Injs --- # Table of IFO-coincident, consistent, scheduled, and known type network injections. | Inj UID | Inj Name | Inj Type | H1 UID | H1 Type | H1 GPS Time | H1 FrFlags | L1 UID | L1 Type | L1 GPS Time | L1 FrFlags | - --------- ---------------------------------- ---------- -------- ---------- ------------------ ------------ -------- ---------- ------------------ ------------ - # --- end Table 2:Normal Network Injs --- # # --- Table 3:Anomalous Network Injs --- # Table of non-IFO-coincident, inconsistent, unscheduled, or unknown type network injections. | Inj UID | Inj Name | Inj Type | H1 UID | H1 Type | H1 GPS Time | H1 FrFlags | L1 UID | L1 Type | L1 GPS Time | L1 FrFlags | - --------- ---------------------------------- ---------- -------- ---------- ------------------ ------------ -------- ---------- ------------------ ------------ - | - | UNSCHEDULED | CALRESET | - | - | - | - | - | CALRESET | 1133582391.811 | 00X00X | | 0 | coherentbbh10_1128678894_ | CBC | 0 | CBC | 1134345929.942 | 00XXXX | 0 | CBC | 1134345929.942 | 00XXXX | | 1 | coherentbbh11_1128678894_ | CBC | - | - | - | - | 1 | CBC | 1134348934.048 | 00XXXX | | 2 | coherentbbh15_1128678894_ | CBC | 2 | CBC | 1134353734.202 | 00XXXX | 2 | CBC | 1134353734.202 | 00XXXX | | 3 | coherentbbh16_1128678894_ | CBC | 3 | CBC | 1134354934.233 | 00XXXX | 3 | CBC | 1134354934.233 | 00XXXX | | 4 | coherentbbh17_1128678894_ | CBC | 4 | CBC | 1134356134.157 | 00XXXX | 4 | CBC | 1134356134.158 | 00XXXX | | 5 | coherentbbh18_1128678894_ | CBC | - | - | - | - | 5 | CBC | 1134357333.938 | 00XXXX | | 6 | coherentbbh11_1128678894_ | CBC | 6 | CBC | 1134359806.048 | 00XXXX | 6 | CBC | 1134359806.048 | 00XXXX | | 7 | coherentbbh12_1128678894_ | CBC | 7 | CBC | 1134361005.933 | 00XXXX | 7 | CBC | 1134361005.934 | 00XXXX | | 8 | coherentbbh13_1128678894_ | CBC | 8 | CBC | 1134362206.003 | 00XXXX | 8 | CBC | 1134362206.004 | 00XXXX | | 9 | coherentbbh14_1128678894_ | CBC | 9 | CBC | 1134363405.957 | 00XXXX | 9 | CBC | 1134363405.957 | 00XXXX | | 10 | coherentbbh19_1128678894_ | CBC | 10 | CBC | 1134364606.129 | 00XXXX | 10 | CBC | 1134364606.130 | 00XXXX | | 12 | WNB_burst_1134573920_1_ | BURST | 12 | BURST | 1134581196.000 | 00XXXX | 12 | BURST | 1134581196.000 | 00XXXX | | - | UNSCHEDULED | CALRESET | - | - | - | - | - | CALRESET | 1134765837.000 | 00X00X | | - | UNSCHEDULED | CALRESET | - | CALRESET | 1134768240.248 | 00X00X | - | - | - | - | | - | UNSCHEDULED | CALRESET | - | - | - | - | - | CALRESET | 1135328440.000 | 00X00X | | - | UNSCHEDULED | CALRESET | - | - | - | - | - | CALRESET | 1135349683.938 | 000XX0 | | - | UNSCHEDULED | CALRESET | - | - | - | - | - | CALRESET | 1135349696.938 | XX0000 | # --- end Table 3:Anomalous Network Injs --- # # --- Table 4:H1 IFO Injs --- # Table of all H1 IFO injections. | Inj UID | Inj Name | Inj Type | GPS Time | FrFlags | - --------- ---------------------------------- ---------- ------------------ ------------ - | 0 | coherentbbh10_1128678894_ | CBC | 1134345929.942 | 00XXXX | | 2 | coherentbbh15_1128678894_ | CBC | 1134353734.202 | 00XXXX | | 3 | coherentbbh16_1128678894_ | CBC | 1134354934.233 | 00XXXX | | 4 | coherentbbh17_1128678894_ | CBC | 1134356134.157 | 00XXXX | | 6 | coherentbbh11_1128678894_ | CBC | 1134359806.048 | 00XXXX | | 7 | coherentbbh12_1128678894_ | CBC | 1134361005.933 | 00XXXX | | 8 | coherentbbh13_1128678894_ | CBC | 1134362206.003 | 00XXXX | | 9 | coherentbbh14_1128678894_ | CBC | 1134363405.957 | 00XXXX | | 10 | coherentbbh19_1128678894_ | CBC | 1134364606.129 | 00XXXX | | 12 | WNB_burst_1134573920_1_ | BURST | 1134581196.000 | 00XXXX | | - | UNSCHEDULED | CALRESET | 1134768240.248 | 00X00X | # --- end Table 4:H1 IFO Injs --- # # --- Table 5:H1-only IFO Injs --- # Table of all H1-only IFO injections. | Inj UID | Inj Name | Inj Type | GPS Time | FrFlags | - --------- ---------------------------------- ---------- ------------------ ------------ - | - | UNSCHEDULED | CALRESET | 1134768240.248 | 00X00X | # --- end Table 5:H1-only IFO Injs --- # # --- Table 6:L1 IFO Injs --- # Table of all L1 IFO injections. | Inj UID | Inj Name | Inj Type | GPS Time | FrFlags | - --------- ---------------------------------- ---------- ------------------ ------------ - | - | UNSCHEDULED | CALRESET | 1133582391.811 | 00X00X | | 0 | coherentbbh10_1128678894_ | CBC | 1134345929.942 | 00XXXX | | 1 | coherentbbh11_1128678894_ | CBC | 1134348934.048 | 00XXXX | | 2 | coherentbbh15_1128678894_ | CBC | 1134353734.202 | 00XXXX | | 3 | coherentbbh16_1128678894_ | CBC | 1134354934.233 | 00XXXX | | 4 | coherentbbh17_1128678894_ | CBC | 1134356134.158 | 00XXXX | | 5 | coherentbbh18_1128678894_ | CBC | 1134357333.938 | 00XXXX | | 6 | coherentbbh11_1128678894_ | CBC | 1134359806.048 | 00XXXX | | 7 | coherentbbh12_1128678894_ | CBC | 1134361005.934 | 00XXXX | | 8 | coherentbbh13_1128678894_ | CBC | 1134362206.004 | 00XXXX | | 9 | coherentbbh14_1128678894_ | CBC | 1134363405.957 | 00XXXX | | 10 | coherentbbh19_1128678894_ | CBC | 1134364606.130 | 00XXXX | | 12 | WNB_burst_1134573920_1_ | BURST | 1134581196.000 | 00XXXX | | - | UNSCHEDULED | CALRESET | 1134765837.000 | 00X00X | | - | UNSCHEDULED | CALRESET | 1135328440.000 | 00X00X | | - | UNSCHEDULED | CALRESET | 1135349683.938 | 000XX0 | | - | UNSCHEDULED | CALRESET | 1135349696.938 | XX0000 | # --- end Table 6:L1 IFO Injs --- # # --- Table 7:L1-only IFO Injs --- # Table of all L1-only IFO injections. | Inj UID | Inj Name | Inj Type | GPS Time | FrFlags | - --------- ---------------------------------- ---------- ------------------ ------------ - | - | UNSCHEDULED | CALRESET | 1133582391.811 | 00X00X | | 1 | coherentbbh11_1128678894_ | CBC | 1134348934.048 | 00XXXX | | 5 | coherentbbh18_1128678894_ | CBC | 1134357333.938 | 00XXXX | | - | UNSCHEDULED | CALRESET | 1134765837.000 | 00X00X | | - | UNSCHEDULED | CALRESET | 1135328440.000 | 00X00X | | - | UNSCHEDULED | CALRESET | 1135349683.938 | 000XX0 | | - | UNSCHEDULED | CALRESET | 1135349696.938 | XX0000 | # --- end Table 7:L1-only IFO Injs --- # #---------------------------------- END REPORT ----------------------------------#