# H1 DARM noise budget from 2015-12-02 5:30:00 to 2015-12-02 6:30:00 Z. # Traces as follows: # [00] Frequency [Hz] # [01] Measured [m/rtHz] # [02] Quantum noise [m/rtHz] # [03] Dark noise [m/rtHz] # [04] Seismic+Newtonian [m/rtHz] # [05] Thermal [m/rtHz] # [06] Actuator noise [m/rtHz] # [07] Ambient electrostatic [m/rtHz] # [08] Gas noise [m/rtHz] # [09] LSC [m/rtHz] # [10] ASC [m/rtHz] # [11] Intensity+Frequency [m/rtHz] # [12] Jitter [m/rtHz] # [13] SRM PEEK ($1/f^{1/2}$) [m/rtHz] # [14] Total expected [m/rtHz] 0.000000000000000000e+00 6.545099338822718417e-14 1.738556499395551338e-15 4.765391223064116939e-17 6.455100000000029749e-10 1.847960000029326689e-14 3.802965617808638167e-12 7.078400000000001778e-16 3.995748034273862613e-17 0.000000000000000000e+00 0.000000000000000000e+00 1.815168824961145134e-15 0.000000000000000000e+00 8.447313313194117272e-17 6.455212025919978809e-10 1.000000000000000056e-01 1.828287383990121588e-13 1.738556499395551338e-15 4.765391436100216788e-17 6.455100000000029749e-10 1.847960000029326689e-14 3.802965617808638167e-12 7.078400000000001778e-16 4.206409289902844784e-17 0.000000000000000000e+00 0.000000000000000000e+00 4.961449340775052989e-15 0.000000000000000000e+00 8.447313313194117272e-17 6.455212026085126452e-10 2.000000000000000111e-01 2.014157868127702346e-13 4.346426344090832949e-16 4.765392075208459019e-17 6.455100000000029749e-10 1.847960000029326689e-14 2.255300348750848317e-12 1.769614471381773651e-16 5.021989388996556276e-17 0.000000000000000000e+00 0.000000000000000000e+00 5.201188646364995866e-15 0.000000000000000000e+00 2.111932388019597051e-17 6.455139400883920569e-10 3.000000000000000444e-01 1.666891211795513004e-13 1.933922628340155251e-16 4.496191403862618637e-17 6.455100000000029749e-10 1.847960000029326689e-14 2.287879559581052780e-12 7.873820402714491966e-17 7.617389753396273149e-17 0.000000000000000000e+00 0.000000000000000000e+00 2.058010676270443098e-15 0.000000000000000000e+00 9.386725978825799949e-18 6.455140547181491119e-10 4.000000000000000222e-01 8.596133072855905952e-14 1.086615021892175600e-16 3.964530340912646262e-17 6.455100000000029749e-10 1.847960000029326689e-14 6.543990416886888668e-12 4.424072268034136642e-17 2.460267819514383181e-16 0.000000000000000000e+00 0.000000000000000000e+00 5.703479157146951309e-16 0.000000000000000000e+00 5.280003127973792836e-18 6.455431699371288796e-10 5.000000000000000000e-01 4.351132476523598253e-14 6.960609194173543822e-17 3.447009655831868926e-17 6.455100000000029749e-10 1.847960000029326689e-14 2.044399999278672710e-12 2.833961060033620621e-17 1.009183846524079944e-16 0.000000000000000000e+00 0.000000000000000000e+00 5.050176380927283920e-16 0.000000000000000000e+00 3.379230177794658045e-18 6.455132376745875062e-10 6.000000000000000888e-01 2.617502655674774844e-14 4.834779908528600798e-17 2.885508299146079995e-17 6.455100000000029749e-10 1.847960000029326689e-14 7.099433503615145988e-13 1.968445853875675144e-17 4.174946169668944811e-17 0.000000000000000000e+00 0.000000000000000000e+00 5.412121458781693085e-16 0.000000000000000000e+00 2.346708199565433941e-18 6.455103906687779627e-10 7.000000000000000666e-01 1.185968153123644164e-14 3.550299045317760986e-17 2.324404506932947679e-17 6.455100000000029749e-10 1.847960000029326689e-14 3.487217534503992969e-13 1.445479205324200549e-17 1.952469696253875718e-17 0.000000000000000000e+00 0.000000000000000000e+00 5.167697900794803514e-16 0.000000000000000000e+00 1.724028513792079667e-18 6.455100944591263324e-10 8.000000000000000444e-01 6.123111487761257660e-15 2.716556175478606948e-17 1.949039187188448999e-17 6.455100000000029749e-10 1.847960000029326689e-14 2.456640840417356968e-13 1.106027067177754452e-17 8.936567515044237247e-18 0.000000000000000000e+00 0.000000000000000000e+00 5.000445991578088398e-16 0.000000000000000000e+00 1.320020974121722166e-18 6.455100470113481525e-10 9.000000000000000222e-01 5.188130779288347292e-15 2.149774253623133759e-17 1.764279035537113434e-17 6.455100000000029749e-10 1.847960000029326689e-14 2.781859240571103497e-13 8.752660229259078986e-18 2.816764430974111411e-18 0.000000000000000000e+00 0.000000000000000000e+00 4.928880430172231267e-16 0.000000000000000000e+00 1.042970911511390965e-18 6.455100602075474074e-10 1.000000000000000000e+00 7.210590587333434959e-15 1.740139475973056803e-17 1.588959644238565006e-17 6.455100000000017341e-10 2.613308387096997320e-13 1.080134109394768337e-12 7.084862203363806968e-18 8.892923189193198741e-17 0.000000000000000000e+00 0.000000000000000000e+00 4.975857606351637231e-16 0.000000000000000000e+00 8.447842575001236647e-19 6.455109565946653493e-10 1.100000000000000089e+00 1.122807829198475227e-14 1.437703525152927308e-17 1.548419163269167352e-17 2.506306250003061120e-11 1.119606857186652377e-14 1.864272650435631718e-13 5.853515855261585661e-18 1.940011029223968246e-17 0.000000000000000000e+00 0.000000000000000000e+00 4.652432069864958817e-16 0.000000000000000000e+00 6.981417264125176519e-19 2.506375834895582188e-11 1.200000000000000178e+00 1.614602269597236565e-14 1.208687111858946786e-17 1.509034753267876758e-17 1.014316666671919342e-11 5.928237838593131125e-15 5.426695189983342575e-14 4.921091399377192612e-18 1.160263221753341741e-17 0.000000000000000000e+00 0.000000000000000000e+00 4.294405161080125691e-16 0.000000000000000000e+00 5.866726664580636250e-19 1.014331357396920125e-11 1.300000000000000044e+00 1.288888829459931210e-14 1.030376804372603847e-17 1.468574074952484701e-17 5.630307692376108083e-12 6.627580000621625062e-15 3.039346790293997811e-14 4.195112830448520121e-18 8.529239136874559505e-18 0.000000000000000000e+00 0.000000000000000000e+00 3.683741644363452239e-16 0.000000000000000000e+00 4.998884017941850064e-19 5.630393639404739954e-12 1.400000000000000133e+00 7.528032701803504532e-15 8.875791705660799368e-18 1.427958955291220774e-17 3.666942857221252571e-12 1.580324547868399797e-15 2.246223813644283435e-14 3.613721232310947743e-18 6.733821574606976791e-18 0.000000000000000000e+00 0.000000000000000000e+00 3.116038292473240217e-16 0.000000000000000000e+00 4.309842643032080001e-19 3.667012007770353815e-12 1.500000000000000000e+00 8.137330879133303644e-15 7.738788307622499615e-18 1.389617059623248992e-17 2.680062222304406059e-12 2.138484256980074019e-15 1.367461505061904502e-14 3.150796922368736559e-18 5.533200784501175250e-18 0.000000000000000000e+00 0.000000000000000000e+00 2.621574151941956404e-16 0.000000000000000000e+00 3.754368076212153224e-19 2.680097974450770150e-12 1.600000000000000089e+00 1.058469299476153118e-14 6.791442618698594611e-18 1.251773122208526920e-17 2.174533333412661419e-12 3.566734117656359258e-14 9.998245188483374271e-15 2.765090112785612885e-18 4.659932816268834216e-18 0.000000000000000000e+00 0.000000000000000000e+00 2.159778838129793242e-16 0.000000000000000000e+00 3.300032050602740535e-19 2.174848819834373695e-12 1.700000000000000178e+00 1.753057054071136982e-14 6.023990002024052168e-18 1.115389887114643296e-17 1.985782353010476775e-12 1.367666668949295259e-15 9.736373308600486086e-15 2.452625298942070278e-18 3.992777407266252327e-18 0.000000000000000000e+00 0.000000000000000000e+00 1.699039872151569030e-16 0.000000000000000000e+00 2.923079327837562733e-19 1.985806700073109872e-12 1.800000000000000044e+00 2.185477551862099356e-14 5.374439846297056439e-18 1.014160101489180601e-17 2.163625925977475262e-12 1.414169124888654277e-15 6.195828333798467659e-15 2.188163406248302330e-18 3.461544470730808970e-18 0.000000000000000000e+00 0.000000000000000000e+00 1.259703692913149840e-16 0.000000000000000000e+00 2.607338180333316375e-19 2.163635263102830034e-12 1.900000000000000133e+00 3.332913460655463860e-14 4.822214350203592026e-18 9.521604237510771189e-18 3.571610526341444076e-12 2.545853334427254969e-15 4.848668426308774127e-15 1.963326347809166967e-18 3.021350579161246068e-18 0.000000000000000000e+00 0.000000000000000000e+00 8.172860830679683188e-17 0.000000000000000000e+00 2.340185492060381757e-19 3.571614725811594505e-12 2.000000000000000000e+00 3.515740683484375117e-14 4.350344669678358263e-18 8.992630651667218037e-18 9.080830000008380243e-12 1.190932698434891557e-14 4.183403152936002556e-15 1.771205396030761849e-18 2.756859664457168308e-18 0.000000000000000000e+00 0.000000000000000000e+00 4.563796199604844801e-17 0.000000000000000000e+00 2.111847063467475013e-19 9.080838773162794304e-12 2.100000000000000089e+00 3.695107011264204772e-14 3.944858706853350828e-18 8.932079020663594993e-18 1.257574603225485071e-12 1.288823638314094438e-15 4.041322129103177539e-15 1.606111924584370127e-18 2.543246550681925875e-18 0.000000000000000000e+00 0.000000000000000000e+00 4.295164341570798270e-17 0.000000000000000000e+00 1.915576207588746541e-19 1.257581757969608108e-12 2.200000000000000178e+00 5.716589788149632189e-14 3.594268925251406277e-18 8.875103149705327890e-18 5.373762122222210100e-13 5.963913083672480166e-16 2.978469247070526568e-15 1.463368875391615156e-18 2.261416784706148984e-18 0.000000000000000000e+00 0.000000000000000000e+00 3.942751132064093968e-17 0.000000000000000000e+00 1.745402557415861158e-19 5.373847988894464366e-13 2.300000000000000266e+00 7.811230874151878327e-14 3.289144376799981630e-18 8.587056793293635828e-18 2.943553624765222560e-13 3.583440063930137665e-16 2.281095631291098201e-15 1.339136511982160785e-18 2.039494757873142363e-18 0.000000000000000000e+00 0.000000000000000000e+00 3.569583722644828487e-17 0.000000000000000000e+00 1.596859947666260039e-19 2.943644214084269153e-13 2.400000000000000355e+00 1.067526583161827089e-13 3.021753560013338265e-18 8.067526066566131640e-18 1.829044446631376470e-13 2.512646487305087909e-16 1.825805860966149443e-15 1.230267011431197567e-18 1.851468594339246356e-18 0.000000000000000000e+00 0.000000000000000000e+00 3.604247217414960254e-17 0.000000000000000000e+00 1.466622929502600299e-19 1.829137336471353952e-13 2.500000000000000000e+00 1.507896845138795316e-13 2.785766796016618076e-18 7.550119046544364535e-18 1.224636002833874617e-13 2.096562632017829590e-16 1.492972103427033143e-15 1.134183288743980640e-18 1.692670573620620405e-18 0.000000000000000000e+00 0.000000000000000000e+00 3.350344678913572992e-17 0.000000000000000000e+00 1.351653601440158077e-19 1.224728847836741566e-13 2.600000000000000089e+00 2.264877525761759303e-13 2.576008564157319113e-18 7.057024504275675280e-18 8.744715419268285152e-14 3.059986238921305423e-16 1.236400436535470475e-15 1.048778162090688472e-18 1.553760003593108933e-18 0.000000000000000000e+00 0.000000000000000000e+00 3.107025396361169028e-17 0.000000000000000000e+00 1.249672932233724403e-19 8.745643557179742593e-14 2.700000000000000178e+00 3.459577230474806764e-13 2.388251728066078342e-18 6.564600685684787975e-18 6.584933373738297759e-14 6.020343561735403937e-16 1.032672553356158638e-15 9.723305735600446567e-19 1.431249183098292219e-18 0.000000000000000000e+00 0.000000000000000000e+00 2.942880937934298434e-17 0.000000000000000000e+00 1.158726306827322373e-19 6.586018926093053119e-14 2.800000000000000266e+00 3.033355885495480822e-13 2.219046845729447782e-18 6.081213512942897110e-18 5.216875045020559869e-14 3.362469146685338160e-16 8.675951396842583481e-16 9.034360941929188164e-19 1.324728071343946226e-18 0.000000000000000000e+00 0.000000000000000000e+00 2.822951310584486085e-17 0.000000000000000000e+00 1.077480744625793606e-19 5.217705576441912132e-14 2.900000000000000355e+00 1.824876175145076350e-13 2.068816710017547626e-18 5.613200115623473371e-18 4.362179358098156713e-14 1.176914439498166251e-16 7.363964023476334408e-16 8.422669376671135183e-19 1.229468343593863015e-18 0.000000000000000000e+00 0.000000000000000000e+00 2.873170403326866849e-17 0.000000000000000000e+00 1.004461361572060551e-19 4.362817747384211956e-14 3.000000000000000000e+00 1.597498962345065058e-13 1.934797598668544538e-18 5.156252293531132656e-18 3.888740047730651953e-14 7.913295826934922055e-17 6.304518710065352170e-16 7.876978804801211176e-19 1.144102470311623579e-18 0.000000000000000000e+00 0.000000000000000000e+00 2.862567235382839960e-17 0.000000000000000000e+00 9.410610421542325180e-20 3.889260211360189369e-14 3.100000000000000089e+00 1.826078328884433767e-13 1.811706577631727016e-18 4.658505859766181797e-18 3.786641979339433885e-14 6.969749365874353380e-17 5.400897745233945056e-16 7.375779064846069434e-19 1.067427289375606882e-18 0.000000000000000000e+00 0.000000000000000000e+00 2.996629273863059521e-17 0.000000000000000000e+00 9.296685332827438770e-20 3.787034759979708070e-14 3.200000000000000178e+00 1.821528460031611905e-13 1.697999068104493610e-18 4.168680711832772944e-18 4.279823993190257892e-14 7.838128822667372411e-17 4.625466482018265761e-16 6.912781255068632787e-19 9.983315385862492438e-19 0.000000000000000000e+00 0.000000000000000000e+00 3.240429789389105345e-17 0.000000000000000000e+00 8.852987077501419251e-20 4.280082366121939408e-14 3.300000000000000266e+00 1.905486343547416482e-13 1.598885091050636165e-18 4.019955235107097352e-18 7.021015170672007815e-14 1.916829597406021228e-16 4.024388889958506119e-16 6.509200465854462082e-19 9.358556828011844242e-19 0.000000000000000000e+00 0.000000000000000000e+00 3.832635825510762519e-17 0.000000000000000000e+00 8.081681397784703136e-20 7.021157732902276205e-14 3.400000000000000355e+00 2.878719184227982287e-13 1.506148646967812696e-18 4.205071245730153844e-18 2.685503922021618329e-13 9.098194409457641195e-16 3.507695505654449561e-16 6.131582800265287742e-19 8.792890385332856346e-19 0.000000000000000000e+00 0.000000000000000000e+00 4.618348798141595675e-17 0.000000000000000000e+00 7.755130762687688629e-20 2.685521664717089613e-13 3.500000000000000000e+00 3.475214980154340956e-13 1.419866500175725540e-18 4.390226911225766698e-18 2.800736831875208444e-14 1.085359046945420946e-16 3.078015057639167461e-16 5.780241004774504442e-19 8.280998325819486168e-19 0.000000000000000000e+00 0.000000000000000000e+00 4.229589518420539173e-17 0.000000000000000000e+00 8.650588344851388041e-20 2.800930226214147472e-14 3.600000000000000089e+00 1.962166275220952118e-13 1.343778446219639886e-18 4.436482653942791671e-18 1.160077864411276201e-14 5.460749565799754252e-17 2.713471112710259919e-16 5.470404263064122105e-19 7.811034428462250295e-19 0.000000000000000000e+00 0.000000000000000000e+00 3.074946264127053458e-17 0.000000000000000000e+00 9.965370187845080678e-20 1.160412186767952637e-14 3.700000000000000178e+00 1.314293453210020799e-13 1.271130722676566419e-18 4.483692729542610688e-18 6.171742027092554534e-15 3.259964339370104829e-17 2.374997943814417408e-16 5.174571232732525968e-19 7.380269293131046375e-19 0.000000000000000000e+00 0.000000000000000000e+00 2.767205514518222417e-17 0.000000000000000000e+00 1.208634445835383447e-19 6.176459894391324593e-15 3.800000000000000266e+00 1.142544850312727302e-13 1.205743204975190427e-18 4.431980690151044957e-18 1.629756455030639247e-14 2.336885892760768814e-17 2.095522289896067045e-16 4.908297406716925802e-19 6.985337905360019054e-19 0.000000000000000000e+00 0.000000000000000000e+00 2.708214392084157550e-17 0.000000000000000000e+00 1.441522645323538792e-19 1.629895161659417195e-14 3.900000000000000355e+00 1.025667474641919947e-13 1.144721245117214261e-18 4.280087785015024424e-18 2.365118642823503880e-15 1.793013335295044899e-17 1.850629529510532904e-16 4.659795669455496786e-19 6.621604040764646553e-19 0.000000000000000000e+00 0.000000000000000000e+00 2.725897583960816799e-17 0.000000000000000000e+00 1.481107985750781688e-19 2.372576519250850180e-15 4.000000000000000000e+00 8.272317564491136212e-14 1.087800049828625087e-18 4.127180029432005579e-18 1.546364584204805832e-15 1.432584488221681072e-17 1.638078933255405985e-16 4.427987995193592547e-19 6.285974250043218022e-19 0.000000000000000000e+00 0.000000000000000000e+00 2.755941165106114840e-17 0.000000000000000000e+00 1.524833147745983682e-19 1.555332773261529701e-15 4.100000000000000533e+00 6.545861267929341729e-14 1.036006130246458897e-18 3.830117842492248188e-18 1.058097161005541959e-15 1.176550841236806207e-17 1.460047503841884138e-16 4.217055318061488965e-19 5.974880693147190377e-19 0.000000000000000000e+00 0.000000000000000000e+00 2.872665793426298386e-17 0.000000000000000000e+00 1.569344198929091761e-19 1.068581742261377251e-15 4.200000000000000178e+00 5.200981429149224495e-14 9.864554246408662069e-19 3.540784667073030156e-18 7.452628659186772184e-16 9.850321808150957564e-18 1.297109448096037060e-16 4.015252539880931824e-19 5.685745712234232218e-19 0.000000000000000000e+00 0.000000000000000000e+00 2.992389637271191351e-17 0.000000000000000000e+00 1.607957945766753705e-19 7.571315325224494616e-16 4.299999999999999822e+00 4.517924082520125412e-14 9.419712587999643501e-19 3.217184706984151162e-18 5.364853082535041826e-16 8.372121519075172667e-18 1.164116291377806805e-16 3.834078555408961338e-19 5.416502430121668681e-19 0.000000000000000000e+00 0.000000000000000000e+00 3.118415719955130407e-17 0.000000000000000000e+00 1.613273130656340587e-19 5.499294513387227367e-16 4.400000000000000355e+00 3.785133744372005023e-14 8.988370304182045908e-19 2.869883590041290156e-18 3.933272839989275431e-16 7.198451993259441830e-18 1.039097194991282471e-16 3.658396877004392720e-19 5.166327781294897058e-19 0.000000000000000000e+00 0.000000000000000000e+00 3.238431400047453722e-17 0.000000000000000000e+00 1.610041198338912797e-19 4.081833098731498885e-16 4.500000000000000000e+00 3.080284695331030544e-14 8.601351169967793808e-19 2.557957336172163395e-18 2.928996548883977273e-16 6.247550450929418221e-18 9.371326335549637050e-17 3.500762137424905432e-19 4.936056695980925462e-19 0.000000000000000000e+00 0.000000000000000000e+00 3.362828112816163990e-17 0.000000000000000000e+00 1.608705397573331728e-19 3.094348910484189591e-16 4.600000000000000533e+00 2.349559769784017915e-14 8.225868202823911694e-19 2.613082930354222642e-18 2.210879298730901651e-16 5.464391241962751543e-18 8.411638662657782430e-17 3.347820476238102470e-19 4.719729121607558993e-19 0.000000000000000000e+00 0.000000000000000000e+00 3.486803785369757878e-17 0.000000000000000000e+00 1.608629868033928975e-19 2.391839134137579086e-16 4.700000000000000178e+00 1.950721433317595885e-14 7.884571243965452112e-19 2.673615834963401929e-18 1.688795727667376099e-16 4.811814727723432592e-18 7.608913426622457663e-17 3.208797941980328064e-19 4.516011962352200902e-19 0.000000000000000000e+00 0.000000000000000000e+00 3.610877546105720854e-17 0.000000000000000000e+00 1.608853695388067475e-19 1.887987456403914752e-16 4.800000000000000711e+00 1.606778436459181985e-14 7.557717034200048260e-19 2.736073941575530014e-18 1.303989310781756217e-16 4.264533399364230595e-18 6.872465444249692167e-17 3.075652858560119306e-19 4.324590816806807822e-19 0.000000000000000000e+00 0.000000000000000000e+00 3.736955082117073587e-17 0.000000000000000000e+00 1.600603378865273961e-19 1.521512190431525401e-16 4.900000000000000355e+00 1.273146956593012169e-14 7.252611498680257659e-19 2.799665143449920931e-18 1.016880081424752737e-16 3.800702355899754176e-18 6.224238108430194053e-17 2.951361555918474278e-19 4.148509446429467329e-19 0.000000000000000000e+00 0.000000000000000000e+00 3.861029550637373731e-17 0.000000000000000000e+00 1.588971448673464727e-19 1.254129731890821865e-16 5.000000000000000000e+00 1.101845131264214244e-14 6.968091291532242023e-19 2.863647694756455717e-18 7.997365865424661161e-17 3.439075271111287745e-18 5.659510962779178673e-17 2.835450605943099214e-19 3.981356018506453970e-19 0.000000000000000000e+00 0.000000000000000000e+00 3.985707762409817241e-17 0.000000000000000000e+00 1.578365252419727242e-19 1.058685799989363486e-16 5.100000000000000533e+00 9.444854943133846510e-15 6.691717859517271539e-19 2.676896591863089455e-18 6.344268534947341623e-17 5.822760898355794009e-18 5.123881423157880672e-17 2.722852813392799967e-19 3.822318707689275063e-19 0.000000000000000000e+00 0.000000000000000000e+00 4.178271170949259068e-17 0.000000000000000000e+00 1.568384851722816683e-19 9.185830586027080043e-17 5.200000000000000178e+00 8.373436889591282890e-15 6.444051613815636378e-19 2.488809563299175273e-18 5.070195760536276030e-17 2.791192278983425422e-18 4.690915678397826901e-17 2.621945232135805061e-19 3.675529546880051527e-19 0.000000000000000000e+00 0.000000000000000000e+00 4.371818963409304213e-17 0.000000000000000000e+00 1.558593932268432071e-19 8.183560300240954107e-17 5.300000000000000711e+00 7.180006768772823799e-15 6.196399542669999306e-19 2.381722459080822652e-18 4.081746500454032322e-17 2.500680562993553891e-18 4.257950709688621259e-17 2.521037650878809675e-19 3.536298724983257639e-19 0.000000000000000000e+00 0.000000000000000000e+00 4.564846538906256725e-17 0.000000000000000000e+00 1.547324787288199278e-19 7.466849923324639148e-17 5.400000000000000355e+00 6.803662228176975771e-15 5.975030261490979978e-19 2.369693946076376708e-18 3.307773070065287160e-17 2.265903103616895784e-18 3.908095157681956314e-17 2.430833699729444567e-19 3.402814411838596640e-19 0.000000000000000000e+00 0.000000000000000000e+00 4.757864399781065574e-17 0.000000000000000000e+00 1.530047260462512196e-19 6.997492034075142152e-17 5.500000000000000000e+00 6.153448786610964462e-15 5.759460701852742814e-19 2.377503783284825293e-18 2.698020243210505017e-17 2.061889391774012969e-18 3.576547069958824263e-17 2.342987469866776455e-19 3.279818709161947311e-19 0.000000000000000000e+00 0.000000000000000000e+00 4.951121700500439939e-17 0.000000000000000000e+00 1.512328154966433810e-19 6.684969552893480881e-17 5.600000000000000533e+00 5.324240104901491679e-15 5.552404308809092127e-19 2.492188175399564358e-18 2.213843343336211578e-17 1.882164598449739942e-18 3.268659796956799043e-17 2.258604654168303397e-19 3.161994125576386330e-19 0.000000000000000000e+00 0.000000000000000000e+00 5.144169827503198248e-17 0.000000000000000000e+00 1.495547160836988552e-19 6.492308866783669911e-17 5.700000000000000178e+00 4.475606004647219131e-15 5.364763969643361059e-19 2.610866380688730360e-18 1.827470394438620432e-17 1.723274711573018091e-18 3.014790942226457136e-17 2.182129130674872048e-19 3.049523375710490462e-19 0.000000000000000000e+00 0.000000000000000000e+00 5.337591666483870924e-17 0.000000000000000000e+00 1.479521560464339786e-19 6.404753184282587766e-17 5.800000000000000711e+00 3.785396170477250827e-15 5.177137738608477632e-19 2.648311166518546929e-18 1.517376113080574511e-17 1.582115660143327043e-18 2.760923564884128318e-17 2.105653607181439976e-19 2.945121067035922522e-19 0.000000000000000000e+00 0.000000000000000000e+00 5.530944240089455496e-17 0.000000000000000000e+00 1.464063709356308009e-19 6.373056188511031214e-17 5.900000000000000355e+00 3.627574979096307558e-15 5.005815429700633963e-19 2.603716196450394601e-18 1.267104359357367387e-17 1.456151337818417745e-18 2.547061853720026604e-17 2.035817907549106149e-19 2.843673781084693655e-19 0.000000000000000000e+00 0.000000000000000000e+00 5.724369475991007956e-17 0.000000000000000000e+00 1.448939367679248443e-19 6.399564005007835775e-17 6.000000000000000000e+00 3.086271316432203515e-15 4.842501805660827500e-19 2.559133199423004728e-18 1.063889643348412577e-17 1.343526177093265703e-18 2.352837182228197645e-17 1.969241280382095038e-19 2.749342341050706110e-19 0.000000000000000000e+00 0.000000000000000000e+00 5.917815590166540806e-17 0.000000000000000000e+00 1.428977221497174845e-19 6.463395427416114803e-17 6.100000000000000533e+00 2.841139257126577692e-15 4.679202719488243695e-19 2.338896933294631611e-18 8.986921130902473967e-18 1.242350312657402519e-18 2.158614529094416063e-17 1.902664653215083446e-19 2.658711651577222870e-19 0.000000000000000000e+00 0.000000000000000000e+00 5.899003798801048634e-17 0.000000000000000000e+00 1.405661468616215175e-19 6.351307323655894361e-17 6.200000000000000178e+00 2.557458260220619414e-15 4.535202227391569634e-19 2.135327957599719275e-18 7.635914534978432456e-18 1.151365494599740376e-18 2.006111409561609659e-17 1.843950581689445564e-19 2.572217443722663891e-19 0.000000000000000000e+00 0.000000000000000000e+00 5.879916470212062867e-17 0.000000000000000000e+00 1.383343946987437816e-19 6.264429350514728468e-17 6.300000000000000711e+00 2.379134552778594942e-15 4.393067019696527025e-19 1.954065753458006859e-18 6.527428713390238671e-18 1.069379718775928697e-18 1.857616305889189565e-17 1.785991550061293919e-19 2.490905303309116484e-19 0.000000000000000000e+00 0.000000000000000000e+00 5.860725561210099603e-17 0.000000000000000000e+00 1.362014122204874609e-19 6.186888556363688762e-17 6.400000000000000355e+00 1.912787605711267860e-15 4.251379960667722581e-19 1.788621336362695288e-18 5.615852187942733973e-18 9.952492600770256650e-19 1.709947325908936797e-17 1.728209272282711071e-19 2.411811317342972433e-19 0.000000000000000000e+00 0.000000000000000000e+00 5.841658607117003398e-17 0.000000000000000000e+00 1.341457785965961581e-19 6.116292806869970689e-17 6.500000000000000000e+00 1.703138038903547890e-15 4.127668573538710565e-19 1.640791881415479571e-18 4.864553212978981515e-18 9.281411069864887707e-19 1.596419574906009410e-17 1.677752385380853434e-19 2.338475153876212345e-19 0.000000000000000000e+00 0.000000000000000000e+00 5.822787665227219773e-17 0.000000000000000000e+00 1.321689000354078793e-19 6.060387252897971162e-17 6.600000000000000533e+00 1.580181670495945675e-15 4.003970668344264738e-19 1.453048186749704650e-18 4.244131263817740165e-18 8.672193131716779918e-19 1.482893843143743035e-17 1.627295498478995075e-19 2.265950704787408547e-19 0.000000000000000000e+00 0.000000000000000000e+00 5.803618328953668730e-17 0.000000000000000000e+00 1.302580668872342067e-19 6.007684383838924721e-17 6.700000000000000178e+00 1.328619059193849486e-15 3.880287534437812862e-19 1.265027876961301264e-18 3.730378611773342189e-18 8.119020802069269584e-19 1.369370632829089209e-17 1.576838611577137197e-19 2.199530578723288548e-19 0.000000000000000000e+00 0.000000000000000000e+00 5.784718355886172177e-17 0.000000000000000000e+00 1.284556922391411777e-19 5.958380446504511148e-17 6.800000000000000711e+00 1.206094797764784284e-15 3.772596950830287720e-19 1.188132843558258612e-18 3.304909596753234604e-18 7.615908587953569713e-19 1.282577629006376131e-17 1.532900555152597928e-19 2.133486297276652905e-19 0.000000000000000000e+00 0.000000000000000000e+00 5.765719520313690566e-17 0.000000000000000000e+00 1.268158954131591479e-19 5.917764972095494890e-17 6.900000000000000355e+00 1.032442940166935128e-15 3.664949766214038394e-19 1.228717513941335772e-18 2.952234653057094784e-18 7.157515880231948933e-19 1.195836846263518744e-17 1.488974744725663597e-19 2.072603241654362913e-19 0.000000000000000000e+00 0.000000000000000000e+00 5.746867964337665887e-17 0.000000000000000000e+00 1.252902352046288415e-19 5.879289579756674825e-17 7.000000000000000000e+00 9.860086300553420166e-16 3.557317179216195248e-19 1.276901117987246446e-18 2.659310890519182843e-18 6.740004540517417264e-19 1.109098546678563627e-17 1.445048934298729267e-19 2.012126068303208548e-19 0.000000000000000000e+00 0.000000000000000000e+00 5.727654337654960832e-17 0.000000000000000000e+00 1.238610566967309431e-19 5.842064979160798483e-17 7.100000000000000533e+00 7.421492932407048606e-16 3.461256127544545739e-19 1.232035171769438447e-18 2.415556665990016004e-18 6.358753797596059518e-19 1.039374657084298957e-17 1.405840079735426432e-19 1.956421012249690403e-19 1.223620498708195954e-15 1.824418591332969116e-16 5.293774541245770181e-17 0.000000000000000000e+00 1.225254176039603611e-19 1.238325700975847301e-15 7.200000000000000178e+00 6.070644719177820283e-16 3.367581781647098522e-19 1.199906779761867326e-18 2.212860431684703399e-18 6.010293648097702603e-19 9.731464552709940586e-18 1.367599971394697171e-19 1.900860987730093451e-19 1.954914359299398630e-16 1.901021917106139819e-16 4.933205653320042842e-17 0.000000000000000000e+00 1.212864634437689538e-19 2.772922262444991338e-16 7.300000000000000711e+00 5.295345817612840355e-16 3.273921696139981895e-19 1.136849327999065567e-18 2.043606041657046379e-18 5.692473674103046210e-19 9.069204931365172464e-18 1.329359863053967429e-19 1.849767508877795461e-19 3.104365612999621599e-16 1.767570173757383900e-16 4.644979816174749626e-17 0.000000000000000000e+00 1.201419603410425826e-19 3.603605171399580727e-16 7.400000000000000355e+00 4.762975977442494875e-16 3.186473870216963765e-19 1.049625533721417333e-18 1.901624886624380765e-18 5.402770174484396601e-19 8.487067169721920779e-18 1.293650419705698097e-19 1.798674105070500072e-19 7.938049437477408978e-16 1.345857718656797621e-16 4.426026568501828041e-17 0.000000000000000000e+00 1.190821677093733768e-19 8.063967973207929232e-16 7.500000000000000000e+00 4.580382143745249775e-16 3.104963281683500742e-19 9.860634756572560378e-19 1.782216150327209116e-18 5.138000000255362064e-19 7.981512247079876559e-18 1.260360063268379794e-19 1.751603279752327322e-19 1.544426136991558870e-15 1.331717513090751631e-16 4.270009509870225556e-17 0.000000000000000000e+00 1.180049845910652570e-19 1.550767029612755967e-15 7.600000000000000533e+00 4.062386289343198854e-16 3.023466481808285333e-19 1.066901763719196900e-18 1.681027627017740707e-18 4.897038273174986605e-19 7.475976715393890351e-18 1.227069706831061010e-19 1.704860709898515136e-19 7.556790011758911200e-16 9.156521765269927557e-17 4.168076733257330528e-17 0.000000000000000000e+00 1.168754547504466428e-19 7.623860384570426707e-16 7.700000000000000178e+00 3.651731587144280420e-16 2.942364279717370272e-19 1.100562257880543528e-18 1.594696602999939299e-18 4.678817335235759015e-19 6.974769612213702229e-18 1.193934480835300520e-19 1.660996858491463777e-19 2.722470146929605262e-16 8.764933882469764597e-17 3.871094166304107547e-17 0.000000000000000000e+00 1.157924594406521784e-19 2.887077121518310421e-16 7.800000000000000711e+00 3.291015878461449899e-16 2.871442428071483689e-19 1.114368224241599802e-18 1.520439329995952254e-18 4.480969817147101288e-19 6.588853169679423457e-18 1.164953186591859941e-19 1.618062030181073089e-19 3.785351117640718846e-16 1.141736011023217447e-16 3.508496711762003309e-17 0.000000000000000000e+00 1.147751461500134158e-19 3.969920649728454265e-16 7.900000000000000355e+00 2.594080753245571080e-16 2.800533789481091945e-19 1.127905078658034656e-18 1.455873497019670140e-18 4.303671904186130003e-19 6.202952885876338586e-18 1.135971892348419844e-19 1.577067254893810447e-19 1.069785816446936723e-16 8.886467705154411175e-17 3.163485039622369141e-17 0.000000000000000000e+00 1.138216220707890479e-19 1.427735768855540937e-16 8.000000000000000000e+00 2.026671419850676614e-16 2.729639393664576070e-19 1.133126818628671803e-18 1.399167547166758033e-18 4.145705811979908852e-19 5.817071976680421378e-18 1.106990598104979506e-19 1.537834799858372179e-19 1.154944441769679454e-15 7.972168394110728267e-17 2.836436841890030782e-17 0.000000000000000000e+00 1.129250406180303411e-19 1.158056182949369708e-15 8.099999999999999645e+00 1.798683286438673018e-16 2.662396634119826209e-19 1.015511576550181591e-18 1.348847322459333119e-18 4.006666801102674241e-19 5.467460953149430815e-18 1.079496267345998536e-19 1.499330393940881342e-19 1.938954466141719292e-16 5.804181815819258769e-17 2.578407749639624534e-17 0.000000000000000000e+00 1.120825380674169481e-19 2.041130505875951204e-16 8.200000000000001066e+00 1.615402896782100585e-16 2.600704872663446082e-19 9.052663503176461766e-19 1.303679634354163907e-18 3.887580845110761068e-19 5.173062918294883637e-18 1.054266275663382177e-19 1.463310149536589497e-19 2.493826778300081984e-15 5.276195633700723974e-17 2.332141015137307496e-17 0.000000000000000000e+00 1.112912314435138465e-19 2.494499800706550215e-15 8.300000000000000711e+00 1.414428999429103653e-16 2.539026590309642679e-19 8.137281201087262101e-19 1.262676559405071036e-18 3.787597990830848591e-19 4.878680189729482344e-18 1.029036283980766420e-19 1.427289987431116777e-19 1.033341235230593404e-16 4.279668554668418116e-17 2.097428560659452583e-17 0.000000000000000000e+00 1.105482002881580800e-19 1.139110493669622415e-16 8.400000000000000355e+00 1.267794989063448139e-16 2.477362793816165496e-19 7.684022508284102131e-19 1.225023791102592315e-18 3.710889886907441447e-19 4.584315716143206945e-18 1.003806292298150543e-19 1.393903216980773896e-19 1.438459335718927626e-16 4.384497217314212074e-17 1.954218532571532168e-17 0.000000000000000000e+00 1.098697670310545422e-19 1.517210563199142131e-16 8.500000000000000000e+00 1.220438283163818298e-16 2.420379379593880346e-19 7.281799472625067012e-19 1.190155194889211806e-18 3.656843852189305790e-19 4.330765342001551453e-18 9.804856279037752192e-20 1.360938049974138050e-19 2.017715360782996340e-16 3.760455681106034251e-17 1.824783851274950809e-17 0.000000000000000000e+00 1.092664772054849534e-19 2.061062194603832976e-16 8.599999999999999645e+00 1.147617213932968061e-16 2.366723378918417659e-19 6.908574490829885345e-19 1.157524279714668432e-18 3.631226917572227054e-19 4.106208768842098069e-18 9.585213748597986144e-20 1.329135440291771236e-19 1.178339054013543545e-16 3.640522917733943586e-17 1.700423938814820340e-17 0.000000000000000000e+00 1.087199426736145015e-19 1.245721428459788175e-16 8.700000000000001066e+00 8.738392426419037057e-17 2.313080934094597834e-19 6.584432307783164443e-19 1.126829820367377824e-18 3.637665137152455966e-19 3.881666072742872773e-18 9.365571218158216486e-20 1.298885426478043002e-19 1.165591748264959509e-16 3.107751492049186345e-17 1.581111205017257132e-17 0.000000000000000000e+00 1.082246573714729117e-19 1.217326506861476400e-16 8.800000000000000711e+00 8.196227399882414800e-17 2.259453010624925657e-19 6.213931975993204566e-19 1.097816863842531326e-18 3.686768626982760098e-19 3.657139809794520148e-18 9.145928687718450438e-20 1.268635484546944011e-19 1.865791202830790403e-16 3.149247681953494218e-17 1.466978128367613215e-17 0.000000000000000000e+00 1.077786242230661528e-19 1.898260671167412606e-16 8.900000000000000355e+00 7.852642789989265456e-17 2.209952922051191611e-19 5.784347107854927341e-19 1.070378289914397864e-18 3.791298914630440433e-19 3.464186657819820529e-18 8.943135802382207542e-20 1.240753567381176102e-19 2.185150317502690421e-16 2.786642174628897455e-17 1.357880235034892786e-17 0.000000000000000000e+00 1.073798000874325931e-19 2.207338868912259613e-16 9.000000000000000000e+00 7.147880238705376611e-17 2.163292564239589047e-19 5.384820318824934242e-19 1.044508260802594335e-18 3.970058860206182540e-19 3.292932684077846425e-18 8.751923526988457917e-20 1.213069069441634407e-19 1.095065235705533610e-16 3.024283037557062011e-17 1.253524928029732355e-17 0.000000000000000000e+00 1.070260760063691422e-19 1.143499128806147523e-16 9.099999999999999645e+00 6.583255856527190896e-17 2.116645660825890884e-19 4.716107418949295263e-19 1.020467399931737077e-18 4.267487594439207857e-19 3.121690779747563024e-18 8.560711251594708292e-20 1.186164779797050089e-19 7.890529305682797793e-17 3.026552787092323054e-17 1.181484336659680550e-17 0.000000000000000000e+00 1.067152567636098855e-19 8.539851521064119609e-17 9.200000000000001066e+00 6.349518203015267090e-17 2.070013121378442773e-19 4.058199162851461808e-19 9.990202443316160587e-19 4.738015677055984943e-19 2.950463046319222383e-18 8.369498976200955055e-20 1.160744032356747094e-19 1.043179328824292795e-16 3.736571560870584240e-17 1.106583189774336885e-17 0.000000000000000000e+00 1.064450401294722885e-19 1.114048812618967171e-16 9.300000000000000711e+00 6.829862581851544050e-17 2.025880966068041287e-19 3.593039200006870228e-19 9.818773309811089148e-19 5.526478674280922926e-19 2.795975289800249161e-18 8.188481277584352916e-20 1.135323367024072306e-19 1.879838895580138215e-16 3.653392437415326993e-17 1.034917687041156888e-17 0.000000000000000000e+00 1.062129963410484123e-19 1.918047544331710100e-16 9.400000000000000355e+00 6.526571042493375075e-17 1.985310451771762867e-19 3.309785467784684546e-19 9.738446018150696038e-19 7.022082394581651696e-19 2.665376483569662075e-18 8.022019280501862236e-20 1.111397390789251310e-19 8.362817006747643706e-17 3.442708681801401941e-17 9.666381765590689954e-18 0.000000000000000000e+00 1.058058798337204427e-19 9.100032262111306604e-17 9.500000000000000000e+00 7.560246863244972635e-17 1.944753131344028365e-19 3.052032747200532571e-19 9.907083528807818409e-19 1.016038980174365693e-18 2.534787813776487170e-18 7.855557283419370352e-20 1.088140707094667147e-19 3.343317399933238047e-16 2.079522481366807461e-17 9.016516446421148344e-18 0.000000000000000000e+00 1.047942544249300484e-19 3.351119965942068556e-16 9.600000000000001421e+00 8.256246298494067223e-17 1.904209847824388821e-19 2.873232461013736861e-19 1.115287401496064169e-18 2.655231971832112951e-18 2.404210932153084451e-18 7.689095286336876061e-20 1.064884106817244728e-19 3.725175352765151106e-17 1.819240218935494013e-17 8.399193178148003230e-18 0.000000000000000000e+00 1.037887082971013016e-19 4.246674317936163512e-17 9.700000000000001066e+00 4.627171417451630475e-17 1.863856809785793238e-19 2.704278456244798873e-19 3.806356355726449772e-18 6.606039443289525337e-18 2.274683394910127936e-18 7.523353400758562039e-20 1.043455157912867133e-19 6.459833923302787235e-17 1.593622862972702256e-17 7.816348338585792191e-18 0.000000000000000000e+00 1.028261879173788158e-19 6.746437132644561870e-17 9.800000000000000711e+00 3.761933208157056066e-17 1.828587343004336505e-19 2.670366737308993166e-19 1.447861268050146372e-18 1.797894791963715991e-18 2.175115866551663934e-18 7.378438036848839967e-20 1.022104188356717689e-19 3.501326844721369833e-17 1.459826043312850026e-17 7.266635460251506789e-18 0.000000000000000000e+00 1.019062858799541148e-19 3.875607107031269483e-17 9.900000000000000355e+00 5.089549244339404996e-17 1.793330674909136899e-19 2.760520675121525337e-19 8.933274555959182400e-19 8.047805660825113629e-19 2.075556619256679830e-18 7.233522672939117895e-20 1.001020455378072199e-19 1.384475050042030184e-16 2.303968106651410223e-17 6.749703776127586721e-18 0.000000000000000000e+00 1.010246118611963680e-19 1.405346381197639268e-16 1.000000000000000000e+01 5.511986710038761428e-17 1.758087575494485998e-19 2.843624280066583525e-19 8.008835770281821848e-19 5.316184346341061560e-19 1.976006904726331214e-18 7.088607309029395823e-20 9.814803238862051463e-20 1.339818589273325250e-16 2.658443452188218587e-17 6.266855068567034687e-18 0.000000000000000000e+00 1.000435523119450549e-19 1.367556551889811169e-16 1.010000000000000142e+01 4.740474292381358635e-17 1.722858877450418489e-19 2.755835048698555801e-19 7.564514553804080402e-19 4.017640659746598848e-19 1.876468240147575349e-18 6.943691945119670140e-20 9.619402726388593487e-20 6.106643975544744881e-17 3.091507109267086166e-17 5.792612534286649366e-18 0.000000000000000000e+00 9.888134105019373285e-20 6.872256028597772521e-17 1.020000000000000107e+01 3.911371659906013943e-17 1.689686527734750564e-19 2.677919468151854884e-19 7.241395360374619916e-19 3.231280140956446563e-19 1.787515795122700815e-18 6.807177899441618981e-20 9.428013466959677282e-20 9.539743132654576316e-17 2.626076228156346503e-17 5.353215265531715208e-18 0.000000000000000000e+00 9.762742988468396248e-20 9.911055328292863062e-17 1.030000000000000071e+01 3.703232089586925456e-17 1.659043534225552928e-19 2.708140673295703165e-19 6.966271938491903596e-19 2.720677034203208736e-19 1.711605859990619761e-18 6.681020199395041178e-20 9.248425368212925826e-20 7.925274604876443484e-17 2.433918661285997114e-17 5.294210793989721031e-18 0.000000000000000000e+00 9.642157389451571411e-20 8.309653730843965317e-17 1.040000000000000036e+01 3.431610440097813977e-17 1.628413530683610416e-19 2.667941136515207577e-19 6.710048406896926255e-19 2.368499799456918083e-19 1.635703417663623234e-18 6.554862499348464580e-20 9.068838079490447267e-20 5.552306456588995803e-17 2.117068466799929738e-17 5.258355716588304914e-18 0.000000000000000000e+00 9.525870607536300164e-20 5.968215860416653486e-17 1.050000000000000000e+01 3.463321399605552990e-17 1.597797264167723917e-19 2.621980423289377521e-19 6.468081370842549268e-19 2.112297202960925418e-19 1.559809561972173501e-18 6.428704799301886777e-20 8.893503635706945994e-20 5.809896516832801401e-17 2.609069505543093265e-17 5.202666494126842972e-18 0.000000000000000000e+00 9.414751531594955374e-20 6.392411930390587981e-17 1.060000000000000142e+01 3.070089363989999392e-17 1.567195539765480176e-19 2.630322943449055127e-19 6.233271066180423773e-19 1.914184635140710241e-19 1.483925610380899871e-18 6.302547099255307771e-20 8.729376482800703154e-20 1.005147365803971368e-16 2.284193542700045943e-17 5.125944578849415858e-18 0.000000000000000000e+00 9.307153968625066702e-20 1.032181321588402963e-16 1.070000000000000107e+01 3.063444668495081556e-17 1.539164232882438353e-19 2.636378412072500668e-19 6.005224869867161171e-19 1.757405225417665224e-19 1.419645418353359566e-18 6.186930286923479529e-20 8.565250134456356537e-20 1.293395179125181314e-16 2.555414957152556064e-17 5.027753328725835847e-18 0.000000000000000000e+00 9.203547983763555552e-20 1.319451533504408315e-16 1.080000000000000071e+01 2.836281269796704681e-17 1.512549086681146565e-19 2.591399824762501142e-19 5.785390301805298557e-19 1.631182098735498329e-19 1.361738381311190758e-18 6.077102282137477519e-20 8.403927519456778741e-20 5.105797193534077746e-17 2.536580500974614858e-17 4.723475852197578379e-18 0.000000000000000000e+00 9.104048156073693960e-20 5.722741046135113097e-17 1.090000000000000036e+01 2.429659390649901056e-17 1.485946934088758630e-19 2.512260936153325084e-19 5.569978729847039012e-19 1.525784060733221039e-19 1.303837834687426399e-18 5.967274277351475509e-20 8.253197094996435279e-20 2.852822993301814995e-17 2.266108654700091048e-17 4.270911418910670953e-18 0.000000000000000000e+00 9.008593650115483049e-20 3.671188681641286170e-17 1.100000000000000000e+01 2.195031255147430216e-17 1.459358485673763168e-19 2.434002911503305075e-19 5.359852347232398529e-19 1.437456485085104086e-19 1.245944683335023092e-18 5.857446272565473500e-20 8.102467473485235970e-20 2.495726164909527962e-17 2.070200144683759252e-17 3.841401972558220802e-18 0.000000000000000000e+00 8.918125447605652166e-20 3.268260934218163024e-17 1.110000000000000142e+01 1.919189284697820901e-17 1.432784504369266027e-19 2.230773320033357056e-19 5.156244041805882284e-19 1.361337888834678149e-19 1.188060008350277126e-18 5.747618267779469082e-20 7.952445198851980796e-20 2.217091702227670686e-17 1.623052455036383342e-17 3.655416534574419405e-18 0.000000000000000000e+00 8.831828032683617674e-20 2.775112910003984241e-17 1.120000000000000107e+01 1.695607767990998121e-17 1.408342962582760329e-19 2.037902344572521844e-19 4.958755785112500670e-19 1.295263400674370176e-19 1.138641819144803584e-18 5.646547565594339735e-20 7.814871046511990195e-20 2.424645040249596462e-17 1.645818582407954216e-17 3.476891581032605575e-18 0.000000000000000000e+00 8.749152684929373296e-20 2.953791635776204887e-17 1.130000000000000071e+01 1.596480970033415811e-17 1.385234038555146843e-19 1.942926672165854117e-19 4.767398944078503866e-19 1.236948295707542368e-19 1.094500947464431868e-18 5.550935560692373899e-20 7.677297682061381493e-20 2.601610519903944601e-17 1.489715242281255855e-17 3.306430622371297699e-18 0.000000000000000000e+00 8.670074098513659142e-20 3.018624368697274567e-17 1.140000000000000036e+01 1.615794655256197059e-17 1.362137937087086036e-19 1.937282971835325154e-19 4.582393961483729963e-19 1.185005400864085451e-19 1.050365548922556901e-18 5.455323555790406859e-20 7.539725148628755787e-20 2.347892063082140373e-17 1.277317342008843708e-17 3.143359739773557139e-18 0.000000000000000000e+00 8.594796860945827672e-20 2.693870468072502423e-17 1.150000000000000000e+01 1.380345650806298065e-17 1.339055321671426807e-19 1.932663051407074114e-19 4.401891369753587166e-19 1.137760224204869971e-19 1.006236343705555135e-18 5.359711550888441023e-20 7.410692175593383047e-20 1.175384849530302666e-17 1.280733700054085974e-17 2.988621989088241840e-18 0.000000000000000000e+00 8.524044721292947187e-20 1.767492101553318466e-17 1.160000000000000142e+01 1.260437274525951097e-17 1.315986901950743847e-19 1.946954868533173483e-19 4.229706658173691524e-19 1.095336898185004750e-19 9.621141840198372480e-19 5.264099545986473381e-20 7.283717876087437524e-20 1.599323750278440007e-17 1.171996392718166259e-17 2.842207458427480559e-18 0.000000000000000000e+00 8.456518985843173743e-20 2.006006882282061558e-17 1.170000000000000107e+01 1.244643366961693996e-17 1.293973612745282371e-19 1.963043996334085341e-19 4.062448282259633646e-19 1.056464885716168882e-19 9.216437426185632129e-19 5.172802853937743113e-20 7.156744595585720844e-20 1.566178799120226632e-17 1.016155273485181013e-17 2.704118328457344302e-18 0.000000000000000000e+00 8.391344779362837515e-20 1.889329919515262307e-17 1.180000000000000071e+01 1.177803504880331891e-17 1.273916404781435372e-19 1.902958859878807131e-19 3.902274742727037594e-19 1.020860748678188917e-19 8.879849123064956960e-19 5.089566747635112119e-20 7.034919597695613041e-20 1.222232382842441008e-17 1.093889721755518000e-17 2.642777921707780628e-18 0.000000000000000000e+00 8.327631517855246073e-20 1.664473126778310599e-17 1.190000000000000036e+01 1.131799160565703260e-17 1.253871694162264379e-19 1.721496429897566374e-19 3.748109172819997623e-19 9.879322516551520978e-20 8.543305915310235322e-19 5.006330641332480523e-20 6.919070952515216762e-20 9.933614823378867053e-18 1.068718012795444848e-17 2.588598917931822876e-18 0.000000000000000000e+00 8.254789512252288581e-20 1.485035205895642368e-17 1.200000000000000000e+01 1.094617310878094563e-17 1.233840089975741422e-19 1.549460359093617051e-19 3.598606535864607012e-19 9.572511814409888601e-20 8.206813350706069063e-19 4.923094535029849530e-20 6.803223112267342663e-20 1.388821022336312526e-17 9.723178416130850496e-18 2.535261349954403586e-18 0.000000000000000000e+00 8.184058524019808776e-20 1.716727393951510998e-17 1.210000000000000142e+01 1.011059237506237511e-17 1.213822241105037196e-19 1.531350671615666047e-19 3.456602463662328222e-19 9.287838671524797672e-20 7.870377924893757960e-19 4.839858428727216731e-20 6.687584372028969248e-20 1.456052979556442810e-17 9.260411610146076902e-18 2.597964077214405493e-18 0.000000000000000000e+00 8.116125025249930461e-20 1.747320206183998287e-17 1.220000000000000107e+01 1.054113645950520593e-17 1.193818839494114389e-19 1.516868824788964983e-19 3.319397971161294541e-19 9.021168602992949732e-20 7.534007292573974542e-19 4.756622322424585737e-20 6.581248375566397611e-20 1.585022120024673824e-17 8.506686963922498590e-18 2.660736858942006666e-18 0.000000000000000000e+00 8.051924322695576684e-20 1.820464305580242268e-17 1.230000000000000071e+01 1.046385786715987796e-17 1.175983211184935622e-19 1.517032243524620524e-19 3.188473081960737539e-19 8.771176135698940216e-20 7.263783285305095129e-19 4.682353021777138534e-20 6.474913167177957518e-20 1.160719841588110631e-17 7.858448677384469478e-18 2.724111849531726393e-18 0.000000000000000000e+00 7.991106670430354826e-20 1.430348392489346179e-17 1.240000000000000036e+01 1.035098436261050920e-17 1.158593774720899161e-19 1.535693163944645192e-19 3.062523375922928189e-19 8.534847440534193362e-20 7.006915018950144984e-19 4.609890893203151552e-20 6.368578786338718831e-20 2.791156759047898846e-17 7.867999703417521429e-18 2.787703563567734885e-18 0.000000000000000000e+00 7.932794786827679668e-20 2.914401894263992667e-17 1.250000000000000000e+01 1.080163052371865244e-17 1.141216932081671900e-19 1.558438015200341236e-19 2.942553002316939436e-19 8.313429273105426436e-20 6.750086538382893096e-19 4.537428764629164570e-20 6.266458414144703388e-20 1.614792988252180572e-17 7.948603095691329491e-18 2.852043094843175963e-18 0.000000000000000000e+00 7.877163419110157245e-20 1.823920821613117705e-17 1.260000000000000142e+01 1.198516409307933046e-17 1.123853267438626141e-19 1.524166716443431446e-19 2.828088873700423435e-19 8.104012788985719585e-20 6.493302564526320731e-19 4.464966636055176385e-20 6.168897753265767349e-20 1.568736605611556796e-17 1.018409677285787724e-17 2.916943154084979363e-18 0.000000000000000000e+00 7.825764017820854281e-20 1.894396476604295806e-17 1.270000000000000107e+01 1.298613550555127985e-17 1.106503401174050594e-19 1.488746059356521142e-19 2.717902067926983862e-19 7.904962636291859736e-20 6.236568594930040845e-19 4.392504507481189403e-20 6.071337897914481491e-20 1.997873310293750804e-17 9.723406344551592979e-18 2.982384005258333909e-18 0.000000000000000000e+00 7.776663012679905649e-20 2.242998347417182154e-17 1.280000000000000071e+01 1.283089975880138406e-17 1.089291296426219410e-19 1.475483375863487556e-19 2.612607126887162858e-19 7.714838151247543262e-20 5.983230250117509393e-19 4.320557990066707746e-20 5.973778887556901124e-20 2.070068564547329381e-17 9.373447120401652025e-18 3.054118506322578801e-18 0.000000000000000000e+00 7.729775953210012373e-20 2.293871798452886914e-17 1.290000000000000036e+01 1.471774787649624901e-17 1.074212069992707230e-19 1.492189977358291014e-19 2.511886261761082426e-19 7.535374632928621732e-20 5.787339348189120049e-19 4.257475268989123633e-20 5.882918151119581381e-20 1.992540677913912563e-17 9.480519220920365256e-18 3.142541101380141889e-18 0.000000000000000000e+00 7.686999869676050712e-20 2.229857259042485573e-17 1.300000000000000000e+01 1.522730542072764368e-17 1.059144822036997752e-19 1.518887971849902606e-19 2.415683891553633799e-19 7.363217951572111866e-20 5.591479321939461685e-19 4.194392547911540121e-20 5.793381349491161613e-20 2.205116088781616845e-17 9.379171245703266392e-18 3.244201276679791394e-18 0.000000000000000000e+00 7.646639350619053580e-20 2.419026799950725782e-17 1.310000000000000142e+01 1.550055499431996208e-17 1.044090071142912883e-19 1.570196731477569085e-19 2.324114937667586767e-19 7.200640340469157138e-20 5.395653533693275288e-19 4.131309826833954803e-20 5.703845606432259536e-20 2.467075450129169615e-17 9.240078623946837260e-18 3.210422094245994585e-18 0.000000000000000000e+00 7.608432576129539991e-20 2.654672535095009967e-17 1.320000000000000107e+01 1.656519608258265950e-17 1.029048365798374871e-19 1.587181148485867335e-19 2.236581862556159867e-19 7.044861391240524145e-20 5.199865851638731184e-19 4.068227105756371291e-20 5.614950980530044471e-20 2.403491816888577554e-17 1.054953181811201037e-17 3.103449211694346390e-18 0.000000000000000000e+00 7.573369499219418764e-20 2.643809762953361226e-17 1.330000000000000071e+01 1.525574253853491198e-17 1.014020286546113574e-19 1.576755653579797693e-19 2.152878791250550681e-19 6.895991722947492268e-20 5.004120748525370228e-19 4.005144384678787780e-20 5.533130471639480980e-20 2.866214513290131550e-17 8.861750980301629499e-18 2.997971842991898871e-18 0.000000000000000000e+00 7.539332451195168732e-20 3.015599508544911718e-17 1.340000000000000036e+01 9.108250796811382125e-18 9.990151372807197320e-20 1.540060946718406813e-19 2.073128031570496513e-19 6.753377152958517306e-20 4.808629631202175001e-19 3.942098187484077297e-20 5.451310747884182251e-20 1.670474267585396869e-17 5.008996391761618022e-18 2.893804286009859630e-18 0.000000000000000000e+00 7.506210400638912447e-20 1.768714795450797251e-17 1.350000000000000000e+01 6.200772269039257553e-18 9.859568651024895143e-20 1.504308975853782020e-19 1.996332893780971009e-19 6.615903815450001925e-20 4.659070146060339249e-19 3.887180815101218266e-20 5.369491845155560255e-20 9.530536880740990476e-18 2.778774197533992149e-18 2.791045846527460539e-18 0.000000000000000000e+00 7.477358259172213428e-20 1.032696914990145727e-17 1.360000000000000142e+01 7.063050039653389498e-18 9.729103374294495454e-20 1.427899073168716998e-19 1.923465152099497446e-19 6.484903475834234689e-20 4.509536425069977254e-19 3.832263442718358031e-20 5.289132973493670343e-20 7.799357600042227800e-18 2.756822655474241199e-18 2.689818809349990479e-18 0.000000000000000000e+00 7.450328038323777302e-20 8.714895781353620162e-18 1.370000000000000107e+01 1.200766460117738384e-17 9.598760331517221059e-20 1.351800289918043936e-19 1.854009871224761124e-19 6.359192745332359236e-20 4.360031119091035010e-19 3.777346070335498397e-20 5.213913424750337878e-20 7.168606965662797036e-18 2.662021599565078893e-18 2.589902827625193616e-18 0.000000000000000000e+00 7.425580578026207414e-20 8.090027451292910226e-18 1.380000000000000071e+01 2.886484975161350315e-17 9.468544570675738945e-20 1.310463880619003499e-19 1.787089161192747397e-19 6.237832229075759777e-20 4.210557254941273650e-19 3.722428697952638764e-20 5.138694669117028481e-20 1.006194744760677328e-17 3.033477531028328659e-18 2.491305087180708959e-18 0.000000000000000000e+00 7.404511775954737077e-20 1.081203665816845792e-17 1.390000000000000036e+01 6.909653815314570490e-17 9.338461416239924292e-20 1.303096819766326440e-19 1.723557281828335651e-19 6.121525493119585910e-20 4.061118304374059486e-19 3.667511325569779733e-20 5.063476741939069928e-20 1.712735140617292249e-17 4.999029851579690384e-18 2.394144863830313606e-18 0.000000000000000000e+00 7.385243530499490215e-20 1.800838250162967926e-17 1.400000000000000000e+01 6.285254626852324123e-17 9.208516487963460055e-20 1.297275843352413834e-19 1.662373451228569807e-19 6.009016591122486174e-20 3.911718268790910201e-19 3.612593953186920701e-20 4.989843728450467111e-20 1.203098190338350383e-17 3.215154702294418089e-18 2.298307550623443114e-18 0.000000000000000000e+00 7.369188958258775927e-20 1.267212525006937292e-17 1.410000000000000142e+01 1.931206041105473645e-17 9.089931272801234570e-20 1.359060259815934098e-19 1.604485242632834787e-19 5.901811117736233034e-20 3.785850248907330038e-19 3.562423923154751880e-20 4.921059642185405353e-20 5.582996213099505216e-18 2.540288404887657056e-18 2.179305924688586629e-18 0.000000000000000000e+00 7.356024380523402159e-20 6.525386939329484458e-18 1.420000000000000107e+01 9.958006074581529873e-18 8.977043656769218092e-20 1.426771781930916089e-19 1.548391967730887768e-19 5.797055051629183505e-20 3.671689497440107943e-19 3.514614986921192334e-20 4.852276344774018755e-20 1.359998979630915812e-17 4.666407224349162297e-18 2.062068738566440930e-18 0.000000000000000000e+00 7.344477844443979802e-20 1.453226597882613719e-17 1.430000000000000071e+01 1.562862930776996519e-17 8.864274008126379425e-20 1.449896225580675705e-19 1.495467092473363188e-19 5.697882448650981974e-20 3.557551735570669781e-19 3.466806050687633390e-20 4.783493870245797022e-20 2.591176560041374889e-17 9.436674969254461973e-18 1.946496210594115851e-18 0.000000000000000000e+00 7.337258249836244787e-20 2.764867454634772366e-17 1.440000000000000036e+01 1.703735847395017451e-17 8.751626887102949064e-20 1.426681950607235933e-19 1.444441176637130452e-19 5.601011353216886532e-20 3.443439249369930969e-19 3.418997114454074446e-20 4.715585508203577434e-20 2.841957297588997813e-17 9.887809728975504230e-18 1.832579609425451651e-18 0.000000000000000000e+00 7.331958311335350970e-20 3.014927218141574606e-17 1.450000000000000000e+01 1.463261661948863101e-17 8.639107086689888532e-20 1.403274425968994273e-19 1.395562639816483321e-19 5.507735515310518697e-20 3.329354637783485848e-19 3.371188178220515502e-20 4.652440117920672822e-20 1.956075134437355734e-17 6.006352535714654379e-18 1.720227947621014000e-18 0.000000000000000000e+00 7.329548660912490122e-20 2.053844278585622605e-17 1.460000000000000142e+01 1.060408421579274249e-17 8.526719647311120622e-20 1.277981827391527199e-19 1.348635547161836832e-19 5.417688933491169483e-20 3.215300867935850744e-19 3.323379241986955354e-20 4.589295514344139814e-20 1.656295690074914608e-17 5.866426744806629255e-18 1.609465638022301480e-18 0.000000000000000000e+00 7.330629867554619671e-20 1.764918060224594551e-17 1.470000000000000107e+01 9.100102097349489792e-18 8.414928195160241483e-20 1.154924329595449396e-19 1.303869278090840802e-19 5.330662001257228999e-20 3.102126296135659940e-19 3.275765618012126483e-20 4.526151730400139566e-20 1.298438622781988701e-17 5.022158834699178654e-18 1.500327396965261776e-18 0.000000000000000000e+00 7.332699980820605117e-20 1.400758150845800165e-17 1.480000000000000071e+01 8.053055087441206476e-18 8.317325089409275884e-20 1.094730154349672936e-19 1.260818299218076177e-19 5.246335199541240649e-20 3.014905100184570948e-19 3.234145010823389591e-20 4.463008800877779249e-20 1.094645183752673779e-17 4.969924788123589006e-18 1.392649515542564065e-18 0.000000000000000000e+00 7.329685382304829353e-20 1.210790199978975691e-17 1.490000000000000036e+01 7.036102307808331033e-18 8.219834438913428299e-20 1.094305830936732192e-19 1.219836223867383583e-19 5.165315763148900027e-20 2.927701998638848161e-19 3.192524403634653302e-20 4.404837772225135926e-20 7.958216213739167164e-18 5.743557249410588091e-18 1.286539212439445866e-18 0.000000000000000000e+00 7.322330559484012761e-20 9.904905528241041658e-18 1.500000000000000000e+01 5.946403578073471368e-18 8.122460292940400784e-20 1.093955519294100444e-19 1.180208978232670972e-19 5.086339772938974835e-20 2.840518657978019954e-19 3.150903796445917012e-20 4.346962518024411095e-20 7.493594170108913060e-18 4.708913180607652986e-18 1.181954259135315835e-18 0.000000000000000000e+00 7.306826663937273282e-20 8.935816722704932510e-18 1.510000000000000142e+01 5.784368725289942926e-18 8.025206892327179828e-20 1.089405157173977306e-19 1.142518258395230928e-19 5.010810710349319070e-20 2.753356955351225823e-19 3.109283189257179519e-20 4.289088074139257269e-20 6.747749941229480624e-18 3.796570067644789780e-18 1.127386936779967583e-18 0.000000000000000000e+00 7.293507354544473545e-20 7.831659035465736149e-18 1.520000000000000107e+01 4.997782974661977538e-18 7.928078680609439016e-20 1.086684190322635877e-19 1.106023870558414945e-19 4.936823261647671407e-20 2.666219012874426720e-19 3.067662582068443229e-20 4.231214473820105630e-20 4.748672742324279992e-18 3.468412037191811388e-18 1.072643476797443278e-18 0.000000000000000000e+00 7.281501775338410682e-20 5.986837555724482398e-18 1.530000000000000071e+01 3.988002430085503042e-18 7.831080315909687080e-20 1.078879098638701866e-19 1.071235776046411147e-19 4.865596462852769291e-20 2.579107238836255439e-19 3.026041974879706940e-20 4.176236793702075355e-20 3.966522644680523792e-18 3.062458826989778096e-18 1.018081775504915235e-18 0.000000000000000000e+00 7.272692168501870650e-20 5.123917314043643892e-18 1.540000000000000036e+01 3.707306505499214285e-18 7.735237264103164101e-20 1.064831248156714734e-19 1.037583868748848577e-19 4.796170916959496417e-20 2.493687191585039511e-19 2.984860152475082266e-20 4.123113364376423079e-20 3.762743501548169921e-18 2.665059139838268226e-18 9.643041007414981905e-19 0.000000000000000000e+00 7.264758468233467326e-20 4.721345446464584636e-18 1.550000000000000000e+01 3.425327125461230017e-18 7.651025386337508736e-20 1.050179194966593463e-19 1.005381431143922782e-19 4.729008853894330060e-20 2.427041971579110529e-19 2.948626864742084800e-20 4.069990735194507899e-20 3.285130693187876536e-18 2.821856905610012979e-18 9.111647113875851006e-19 0.000000000000000000e+00 7.260151676675717102e-20 4.436339739182591039e-18 1.560000000000000142e+01 3.135674480273663631e-18 7.566923045545440527e-20 1.002414512957426764e-19 9.745784174850493807e-20 4.664472534740180723e-20 2.360411920164084249e-19 2.912393577009086130e-20 4.016868937901756283e-20 2.963230800302201500e-18 2.202335276928276555e-18 8.590463234368670976e-19 0.000000000000000000e+00 7.256749533600091612e-20 3.802613468252909598e-18 1.570000000000000107e+01 3.120271492532209259e-18 7.482933935058307569e-20 9.559453422754098760e-20 9.447715681877704358e-20 4.601318545054487539e-20 2.293798359187995268e-19 2.876160289276088664e-20 3.964409541782269808e-20 2.733493018093890427e-18 1.894506238132649873e-18 8.075725014648826179e-19 0.000000000000000000e+00 7.255743393097626597e-20 3.435021219331658203e-18 1.580000000000000071e+01 3.058883397891551494e-18 7.399061910816980394e-20 9.083544304929684462e-20 9.162033048266780472e-20 4.540268621151459793e-20 2.227202768292356162e-19 2.839927001543091198e-20 3.915744345889158999e-20 3.266215776030628787e-18 1.707608532974931222e-18 7.569491345718931907e-19 0.000000000000000000e+00 7.256720864550904533e-20 3.773387856225407658e-18 1.590000000000000036e+01 2.882205059078898509e-18 7.315311000099237212e-20 8.586191950371030254e-20 8.885707932628294969e-20 4.480509852689731755e-20 2.160626809118012266e-19 2.803693713810093731e-20 3.867080289221094308e-20 2.716036488504732301e-18 1.699936854257930374e-18 7.072324861030666299e-19 0.000000000000000000e+00 7.259455774976898477e-20 3.292974124042757583e-18 1.600000000000000000e+01 2.502654302577435054e-18 7.231685410791737149e-20 8.105800576436693289e-20 8.620878847472423987e-20 4.422946279951421020e-20 2.094072354094906653e-19 2.767460426077096265e-20 3.818417046399260535e-20 2.449590277200841709e-18 1.732023878493960096e-18 6.582825360320414893e-19 0.000000000000000000e+00 7.264931662535193462e-20 3.083225047802106630e-18 1.610000000000000142e+01 2.724638465931927668e-18 7.148189541244555992e-20 8.037257433449134259e-20 8.366599708958552205e-20 4.367204693837643493e-20 2.027541520858311262e-19 2.731227138344098197e-20 3.769754648941144321e-20 3.220064009737122546e-18 1.610792556218711607e-18 6.360379396571024863e-19 0.000000000000000000e+00 7.271554601019257477e-20 3.665658149294055780e-18 1.619999999999999929e+01 2.500679881918951197e-18 7.073483842165401170e-20 7.983694248715495388e-20 8.120165041039452956e-20 4.312692774585646751e-20 1.973507558475707993e-19 2.698758339212159719e-20 3.723329244834220465e-20 2.608311946199355520e-18 1.373301002153230639e-18 6.141840488459347256e-19 0.000000000000000000e+00 7.281376788081611073e-20 3.022029732660984732e-18 1.630000000000000071e+01 2.407861357814162408e-18 7.001014556604873002e-20 7.657327052327252296e-20 7.883569145642459511e-20 4.259773787870942290e-20 1.922553457515295737e-19 2.667215043027438928e-20 3.678685321098955563e-20 2.415944038137996304e-18 1.437949338795314689e-18 5.927625293558499043e-19 0.000000000000000000e+00 7.291725969157675276e-20 2.884265860359282433e-18 1.640000000000000213e+01 2.420304025523197568e-18 6.928653675535889802e-20 7.062514356923911446e-20 7.656365578427621011e-20 4.208450964150165102e-20 1.871612758681558281e-19 2.635671746842718137e-20 3.634042193115137482e-20 2.387976511284220989e-18 1.251238258883882985e-18 5.716885665767134687e-19 0.000000000000000000e+00 7.305894620795658571e-20 2.766705749829654929e-18 1.650000000000000000e+01 2.222862642747140026e-18 6.856404631185796816e-20 6.496346864783681772e-20 7.436321352889847113e-20 4.158580678777275991e-20 1.820686586902721830e-19 2.604128450657998851e-20 3.589399890574222710e-20 2.322459131958072396e-18 1.113406637918890994e-18 5.508246281021860770e-19 0.000000000000000000e+00 7.318391507185480202e-20 2.644532187177510397e-18 1.660000000000000142e+01 2.226070243771439258e-18 6.784270996568489523e-20 6.493299525551330970e-20 7.224806389401308078e-20 4.110155245234644872e-20 1.769776196248461358e-19 2.572585154473278061e-20 3.544758444662821920e-20 2.385158865868262947e-18 1.145663152334282173e-18 5.327024914098010514e-19 0.000000000000000000e+00 7.315742087243295770e-20 2.709172992386618553e-18 1.669999999999999929e+01 2.249336928919396246e-18 6.712256492456180127e-20 6.528587806982906497e-20 7.020763272899332719e-20 4.062963760986672307e-20 1.718882988949561161e-19 2.541041858288558474e-20 3.503239470185339072e-20 2.708811534782409537e-18 1.125146426899921985e-18 5.147805952557937540e-19 0.000000000000000000e+00 7.309438668739154841e-20 2.986757836290754967e-18 1.680000000000000071e+01 2.131936011950687608e-18 6.640364994747289319e-20 6.700216327251692779e-20 6.823232938456725900e-20 4.016939586406389190e-20 1.668008537869330823e-19 2.509498562103837683e-20 3.462358489940697844e-20 2.193732347925684670e-18 1.013563356391750495e-18 4.970089515467848817e-19 0.000000000000000000e+00 7.287552238406078239e-20 2.477280782015142978e-18 1.690000000000000213e+01 1.930947791942645081e-18 6.570268358085531953e-20 6.989985695382953830e-20 6.633371025774450222e-20 3.972308457447639628e-20 1.619279238149921228e-19 2.478688838216361360e-20 3.421478310147817919e-20 2.047538602937323771e-18 9.859065613967033569e-19 4.794365356907628093e-19 0.000000000000000000e+00 7.266087883922924664e-20 2.332970570821328198e-18 1.700000000000000000e+01 1.898130352400512044e-18 6.507898914654197937e-20 7.257888535685204015e-20 6.449185179198286285e-20 3.928660033574348831e-20 1.580265348139869477e-19 2.451228466926597546e-20 3.380598959845292016e-20 2.029039272806423915e-18 9.199605994829103152e-19 4.619572120493052749e-19 0.000000000000000000e+00 7.245847408368731623e-20 2.285586196034162374e-18 1.710000000000000142e+01 1.719292174690669438e-18 6.445631810181263961e-20 6.809377618871594276e-20 6.271905425764004525e-20 3.886160261103514244e-20 1.541261967613241773e-19 2.423768095636833130e-20 3.339720304082717218e-20 2.136067241497804636e-18 9.752703751390540117e-19 4.480896163658488367e-19 0.000000000000000000e+00 7.226068194879582246e-20 2.399923849078354915e-18 1.719999999999999929e+01 1.764789223094430393e-18 6.383470039441708450e-20 6.364832066457686578e-20 6.099770772059079526e-20 3.844764840374217253e-20 1.502269915142299736e-19 2.396307724347069316e-20 3.302084254021684561e-20 1.941074314783150988e-18 9.407269065985266244e-19 4.342958306107169019e-19 0.000000000000000000e+00 7.207362667545954778e-20 2.210000397796929801e-18 1.730000000000000071e+01 1.799161960253533038e-18 6.321416709840068998e-20 6.193108256502237020e-20 5.935233956744743898e-20 3.804887626839501305e-20 1.463290096297875863e-19 2.368847353057304900e-20 3.264563688633349422e-20 1.589092488904427242e-18 9.720659260646176032e-19 4.207322563696963347e-19 0.000000000000000000e+00 7.189020632595647066e-20 1.920456170751117902e-18 1.740000000000000213e+01 1.734458792055929002e-18 6.259475046472072746e-20 6.273658019562635407e-20 5.774030828015673528e-20 3.765386602771542957e-20 1.424323515482500882e-19 2.341386981767540183e-20 3.227043927689589474e-20 1.327100426544119413e-18 9.502127529535463565e-19 4.071180969996552619e-19 0.000000000000000000e+00 7.171444280565462175e-20 1.693951070027324729e-18 1.750000000000000000e+01 1.630984591899860587e-18 6.197648397443491550e-20 6.355251423479241333e-20 5.619918889643968158e-20 3.727225696129887325e-20 1.385371289741708882e-19 2.313926610477776670e-20 3.189524999579493810e-20 8.738304131925906830e-19 9.024275033880364162e-19 3.937417011974995613e-19 0.000000000000000000e+00 7.154178347113294328e-20 1.330893906083877874e-18 1.760000000000000142e+01 1.578157758852123710e-18 6.135940239460223459e-20 6.486466867623052429e-20 5.470163631079157446e-20 3.689904858544487627e-20 1.346434664948866458e-19 2.286466239188011953e-20 3.152006934043183559e-20 1.060997274120683249e-18 9.978216380308661119e-19 3.804057376007045130e-19 0.000000000000000000e+00 7.137570907136647315e-20 1.517609183878598776e-18 1.769999999999999929e+01 1.579077461941167915e-18 6.075916943538140534e-20 6.623949094984976158e-20 5.325899481691240305e-20 3.653747936444958827e-20 1.309283151601733871e-19 2.259703184847579066e-20 3.117516665825604497e-20 9.503196595416149047e-19 1.006087709008566377e-18 3.671748075201444922e-19 0.000000000000000000e+00 7.121186507188864674e-20 1.444328216808101338e-18 1.780000000000000071e+01 1.627785820268853967e-18 6.022404159570231879e-20 6.555434877670903637e-20 5.185599616407534172e-20 3.618230495461877969e-20 1.279388285877220263e-19 2.235797249749490004e-20 3.083156862007797572e-20 7.607887832281264646e-19 1.090974220629919123e-18 3.540312855381832614e-19 0.000000000000000000e+00 7.105333479514077620e-20 1.388939296754163529e-18 1.790000000000000213e+01 1.553703003796596429e-18 5.968989305169273048e-20 6.279327461416023670e-20 5.050219155575520378e-20 3.583603259067997676e-20 1.249502116433050205e-19 2.211891314651400942e-20 3.048797859206016322e-20 9.804353840829217990e-19 1.165890469657728989e-18 3.410939130098461623e-19 0.000000000000000000e+00 7.089542506199732541e-20 1.571717925770340620e-18 1.800000000000000000e+01 1.293812755288646324e-18 5.915675033064514991e-20 5.995362785374466467e-20 4.919301663727232318e-20 3.550063048628167332e-20 1.219625282560439932e-19 2.187985379553312783e-20 3.014439684810538499e-20 7.509501181313720890e-19 1.082323457704850956e-18 3.280374544172002841e-19 0.000000000000000000e+00 7.073940256500542338e-20 1.369306123118873157e-18 1.810000000000000142e+01 1.220753976153796414e-18 5.862464087395495220e-20 5.436823156772225525e-20 4.792537329933045669e-20 3.517201649042135166e-20 1.189758487555238225e-19 2.164079444455223721e-20 2.980082367474122035e-20 5.077594409695750917e-19 1.148715278357002086e-18 3.166229975107637659e-19 0.000000000000000000e+00 7.058331842044657584e-20 1.306918857064488682e-18 1.819999999999999929e+01 1.064541190026512533e-18 5.809359307424726387e-20 4.894341621244033439e-20 4.669352419015794781e-20 3.484940751908827716e-20 1.159902506902180879e-19 2.140173509357135562e-20 2.947978523693746357e-20 2.591430934820001896e-19 9.179774106217251491e-19 3.053535665819013109e-19 0.000000000000000000e+00 7.042694466830086079e-20 1.015866302562078132e-18 1.830000000000000071e+01 1.032625741757514170e-18 5.756363631417324471e-20 4.666619589614258923e-20 4.550743045950989882e-20 3.453722957663993249e-20 1.130058197742635915e-19 2.116267574259046500e-20 2.916419898141715959e-20 2.734202661202223364e-19 7.740984185419804013e-19 2.941604217315065019e-19 0.000000000000000000e+00 7.027025700216155911e-20 8.878508001998461356e-19 1.840000000000000213e+01 1.003693436641023043e-18 5.703480100695288725e-20 4.732058567604641609e-20 4.435032759866434494e-20 3.423088892419351726e-20 1.100226509865965220e-19 2.092361639160957438e-20 2.884862071164531235e-20 3.540139136098020415e-19 6.983893361377667378e-19 2.830591514087683438e-19 0.000000000000000000e+00 7.010993710412034883e-20 8.485972769085090957e-19 1.850000000000000000e+01 1.013465883491131940e-18 5.650711863874462082e-20 4.803022054770558268e-20 4.323486878503648219e-20 3.393174372147950718e-20 1.070408498517034152e-19 2.068455704062869279e-20 2.853304746135131328e-20 4.242733917595854490e-19 7.097515661254484562e-19 2.720889269326360663e-19 0.000000000000000000e+00 6.994961720607913855e-20 8.853817439767251423e-19 1.860000000000000142e+01 9.070642953636625362e-19 5.603749883279281196e-20 5.108508719847506988e-20 4.214945663697397409e-20 3.363950559102879721e-20 1.046361267756313507e-19 2.047134044448375009e-20 2.821748420930795755e-20 4.000842512085276633e-19 5.543927269536056354e-19 2.612545798239530438e-19 0.000000000000000000e+00 6.939051180919969554e-20 7.492061158548365629e-19 1.869999999999999929e+01 8.824728668060113310e-19 5.558005110688995357e-20 5.421199119218359497e-20 4.110016103863435048e-20 3.335427407133341700e-20 1.023457826585387759e-19 2.026322463756928423e-20 2.791532020647818967e-20 4.372597182903896713e-19 4.246382593273648544e-19 2.505236656182969291e-19 0.000000000000000000e+00 6.881448638502223642e-20 6.778684154055659240e-19 1.880000000000000071e+01 8.915283052079677588e-19 5.512354821792638217e-20 5.331672322158631759e-20 4.008428755110378972e-20 3.307554338672735597e-20 1.000561850527183760e-19 2.005510883065480933e-20 2.762650369566309859e-20 4.591026125004561013e-19 3.918666785910283028e-19 2.399267731117411648e-19 0.000000000000000000e+00 6.803143522835546556e-20 6.680467997945495385e-19 1.890000000000000213e+01 7.949430764231124167e-19 5.466801383536742032e-20 4.856833536856836261e-20 3.909735702033156162e-20 3.280308135795312433e-20 9.776738640544155749e-20 1.984699302374033444e-20 2.733769505432790499e-20 4.765309395436780683e-19 3.383817849732173041e-19 2.293871474975679089e-19 0.000000000000000000e+00 6.720122535966543162e-20 6.460420046933487343e-19 1.900000000000000000e+01 7.608952600197382036e-19 5.421347237314824761e-20 4.432213794582968470e-20 3.814032817859071574e-20 3.253747089226275785e-20 9.547944417375997617e-20 1.963887721682586556e-20 2.704889453454658344e-20 4.492158853939029603e-19 3.105097161534419677e-19 2.189705118641457153e-19 0.000000000000000000e+00 6.638548165241694426e-20 6.068087749483161199e-19 1.910000000000000142e+01 7.182020188111849897e-19 5.375994901675972803e-20 4.704015572236042404e-20 3.721502460774351692e-20 3.227739191952436929e-20 9.319242143458603667e-20 1.943076140991139067e-20 2.676010239926751984e-20 4.353014929215140678e-19 2.970345199086486788e-19 2.119899135091834896e-19 0.000000000000000000e+00 6.557770752308494410e-20 5.867412004855756641e-19 1.920000000000000284e+01 7.030304387393440126e-19 5.330746975139052563e-20 5.024821586790192286e-20 3.631239249757288083e-20 3.202200554233039876e-20 9.090638758571895820e-20 1.922264560299691578e-20 2.647228564117663412e-20 4.252317311594239787e-19 3.167031608185210198e-19 2.050811123577802675e-19 0.000000000000000000e+00 6.477907794124927793e-20 5.868750636839927578e-19 1.930000000000000071e+01 7.161916040023256973e-19 5.285606139116441829e-20 5.124311841402297804e-20 3.543968051709264236e-20 3.177393619771818087e-20 8.862141915395267719e-20 1.901452979608244991e-20 2.620697282383102310e-20 4.229471690640127434e-19 2.945356064013351084e-19 1.982388646900852675e-19 0.000000000000000000e+00 6.399162753775894993e-20 5.706280708255212287e-19 1.940000000000000213e+01 7.003808584239728318e-19 5.241033778995443890e-20 4.987625350633703509e-20 3.459136314240372435e-20 3.153014323684628843e-20 8.637886893093751813e-20 1.880853518224929215e-20 2.594166778806489190e-20 3.833718439571071315e-19 2.394009594507786717e-19 1.914659003936176229e-19 0.000000000000000000e+00 6.320889544391083838e-20 5.107392507244683115e-19 1.950000000000000000e+01 7.150567476036106092e-19 5.201924908299318936e-20 4.855507758412044346e-20 3.377076045146050816e-20 3.129304391759654529e-20 8.461999666821970406e-20 1.862735762567203780e-20 2.567637077509134542e-20 3.618975105805431517e-19 2.667970547236216620e-19 1.847490274063535623e-19 0.000000000000000000e+00 6.244198924139485304e-20 5.055015298883781224e-19 1.960000000000000142e+01 6.704601378611511381e-19 5.162903444359521435e-20 4.864607526196129760e-20 3.296658621837492913e-20 3.105824128564795495e-20 8.286170699838889484e-20 1.844618006909477743e-20 2.541108203618926515e-20 3.654477146837181021e-19 2.837396373071370822e-19 1.781146310097153490e-19 0.000000000000000000e+00 6.167508303887884363e-20 5.143192653644400597e-19 1.970000000000000284e+01 6.606189358495341526e-19 5.123971384107726928e-20 4.882863574189330910e-20 3.219235468661250233e-20 3.083098251699235423e-20 8.110403781230690177e-20 1.826500251251751706e-20 2.514580183323355073e-20 3.576154119535045655e-19 2.707747477613737939e-19 1.716332083937589732e-19 0.000000000000000000e+00 6.092828292716669695e-20 4.989172160971588248e-19 1.980000000000000071e+01 6.381353912226397326e-19 5.085130780984028353e-20 4.962736967331434049e-20 3.143743544439724347e-20 3.060811691153357269e-20 7.934703034423710013e-20 1.808382495594026572e-20 2.489004681240789183e-20 3.222059427244420392e-19 2.132429297077334575e-19 1.652268683339991740e-19 0.000000000000000000e+00 6.018181696082381458e-20 4.409391982848820456e-19 1.990000000000000213e+01 5.890281470382707022e-19 5.046383746748608990e-20 5.123819515979583873e-20 3.070171000926296658e-20 3.038767414666943140e-20 7.759072954712028074e-20 1.790264739936300536e-20 2.464734695139576424e-20 2.879948821570252812e-19 2.290999052725052303e-19 1.588755082299485964e-19 0.000000000000000000e+00 5.944862513883756602e-20 4.221251709750914815e-19 2.000000000000000000e+01 6.076631792617078526e-19 5.007732453353188450e-20 5.295123489914354929e-20 2.999131889323977844e-20 3.017419388178097789e-20 7.583518451929400415e-20 1.772146984278575101e-20 2.440466057811868952e-20 2.649889783902710119e-19 2.154145672295572671e-19 1.525851577446998442e-19 0.000000000000000000e+00 5.872081298005408156e-20 3.964027052652137924e-19 2.010000000000000142e+01 5.716026597079057272e-19 4.969179134873875134e-20 5.041892096309689042e-20 2.929998952251959841e-20 2.996560536822915824e-20 7.408044899102787232e-20 1.754029228620849064e-20 2.416198226979653449e-20 2.740119228463344638e-19 1.949860390958219706e-19 1.470975053055973240e-19 0.000000000000000000e+00 5.800082762017593359e-20 3.889100232046176229e-19 2.020000000000000284e+01 6.065289653855733092e-19 4.930726089507093497e-20 4.777570607322124747e-20 2.862495877724283372e-20 2.975916395468672314e-20 7.232658188083485696e-20 1.735911472963123028e-20 2.391931227190329536e-20 2.362281841028130774e-19 2.033955398054556053e-19 1.416715546636282845e-19 0.000000000000000000e+00 5.729195636476617095e-20 3.647602297736823470e-19 2.030000000000000071e+01 5.625221134469048557e-19 4.892375681630235204e-20 4.487306857340056565e-20 2.797133594059789753e-20 2.955794462625210966e-20 7.057364793344509083e-20 1.717793717305397894e-20 2.367665083996816734e-20 2.332358737054018341e-19 1.679490350311843564e-19 1.362688674673315250e-19 0.000000000000000000e+00 5.658475094989554656e-20 3.409932382381155151e-19 2.040000000000000213e+01 5.729745801599241620e-19 4.858623716332793852e-20 4.170625116106926221e-20 2.733747160947526734e-20 2.936123875205478926e-20 6.918521776161117973e-20 1.701805906410914202e-20 2.344654039814992482e-20 2.495002050449680581e-19 1.491582772855398404e-19 1.309294618295856846e-19 0.000000000000000000e+00 5.589476716188615486e-20 3.407355212502300998e-19 2.050000000000000000e+01 6.688818920964535853e-19 4.825408276649962410e-20 3.874673415953417783e-20 2.671761994078396763e-20 2.916819455472915247e-20 6.783400889772980270e-20 1.686033290436196770e-20 2.322356687985782735e-20 1.973343177484053108e-19 1.328850403539051000e-19 1.256250772298082774e-19 0.000000000000000000e+00 5.520478337387679927e-20 2.936799846693582635e-19 2.060000000000000142e+01 5.383896687904151666e-19 4.792275898018148031e-20 4.169351213337213871e-20 2.611761839904246582e-20 2.897896649956911358e-20 6.648329789423486540e-20 1.670260674461478435e-20 2.300060126465346299e-20 1.584931778183776794e-19 1.431219924179888646e-19 1.203659544461557897e-19 0.000000000000000000e+00 5.452760425654286487e-20 2.717537463336222519e-19 2.070000000000000284e+01 5.071373462432301354e-19 4.759228315179107669e-20 4.483205821725307094e-20 2.553239237361001259e-20 2.879255917453403265e-20 6.513311572457149130e-20 1.654488058486760401e-20 2.277764378462188336e-20 1.526766434264902036e-19 1.455563627096834870e-19 1.151535578989320463e-19 0.000000000000000000e+00 5.385501280835821819e-20 2.672980485381350510e-19 2.080000000000000071e+01 4.702997257705563207e-19 4.726267306891636277e-20 4.547246370799899189e-20 2.496261261316335211e-20 2.861112451908931863e-20 6.378349597213880045e-20 1.638715442512042968e-20 2.255469468101632793e-20 1.430940805168262025e-19 1.160603527713091499e-19 1.099887056740163038e-19 0.000000000000000000e+00 5.327741332123759898e-20 2.438662351518855704e-19 2.090000000000000213e+01 4.902980541226403728e-19 4.693394697156428160e-20 4.363550819174870373e-20 2.441098681124997595e-20 2.843322088275367208e-20 6.243447510955649220e-20 1.622942826537324934e-20 2.233175420471496739e-20 1.335443789321919489e-19 1.208497357364479674e-19 1.048486667501685723e-19 0.000000000000000000e+00 5.287091379197027862e-20 2.374841021345951404e-19 2.100000000000000000e+01 4.870390584815437868e-19 4.660612356473415521e-20 4.181204981523495706e-20 2.387032249604237758e-20 2.825716480791870082e-20 6.108609281435817799e-20 1.607170210562607502e-20 2.212184128906349406e-20 1.077664734632760909e-19 1.063929561643362890e-19 9.976228618207934001e-20 0.000000000000000000e+00 5.246441426270297631e-20 2.130866644366694239e-19 2.110000000000000142e+01 4.587238641026407977e-19 4.627922203132038010e-20 3.799926831174647593e-20 2.334567301472169091e-20 2.808600935706853921e-20 5.973839232673988607e-20 1.591397594587889467e-20 2.191794507428622507e-20 1.087981028851394678e-19 1.328658249606253899e-19 9.615439471223712930e-20 0.000000000000000000e+00 5.216954469694311267e-20 2.251212234971925598e-19 2.120000000000000284e+01 4.293522071724699580e-19 4.595326204534944000e-20 3.422631338798535563e-20 2.283662043612706648e-20 2.791767839422544444e-20 5.839142085600565682e-20 1.575624978613171433e-20 2.171405672432829570e-20 1.022090960262143397e-19 1.110729659929884173e-19 9.258203250582820078e-20 0.000000000000000000e+00 5.188052864751345654e-20 2.067856223183152765e-19 2.130000000000000071e+01 4.396760504988958204e-19 4.564104658947441599e-20 3.269953226321031411e-20 2.234084699395455223e-20 2.775286119570293487e-20 5.713821566169477162e-20 1.560473130525025596e-20 2.151017199394632715e-20 7.933460869188536039e-20 1.073370229543340749e-19 8.903878149815797033e-20 0.000000000000000000e+00 5.159834049640843709e-20 1.918285174470806777e-19 2.140000000000000213e+01 4.347642662054903369e-19 4.535891484178645196e-20 3.327858878713674657e-20 2.185743925800625722e-20 2.759079281078983051e-20 5.609836347094515119e-20 1.546742102279270136e-20 2.130629791198373352e-20 7.174249149571387688e-20 1.071540184176791959e-19 8.534340306546130507e-20 0.000000000000000000e+00 5.132257054833322837e-20 1.865223643363264220e-19 2.150000000000000000e+01 4.858726829738758872e-19 4.507754170303623345e-20 3.382092448132823108e-20 2.138528077032132450e-20 2.743203462586514708e-20 5.505890199482243818e-20 1.533011074033514976e-20 2.110243446911135228e-20 6.676953155968366048e-20 1.001752861272318748e-19 8.156243779719350550e-20 0.000000000000000000e+00 5.104750493862353772e-20 1.784629695372756504e-19 2.160000000000000142e+01 4.355679450042704451e-19 4.479694146787457150e-20 3.453592725582278946e-20 2.092580846119948052e-20 2.727541919960862285e-20 5.401985378797224573e-20 1.519280045787759215e-20 2.090767749699045126e-20 6.557067862269002358e-20 8.506515468883941604e-20 7.783344289560772246e-20 0.000000000000000000e+00 5.078514261956284441e-20 1.677504126285811295e-19 2.170000000000000284e+01 3.862540314722866183e-19 4.451712875159475634e-20 3.524382141162322206e-20 2.047960784914667008e-20 2.712213107896276049e-20 5.298124316504468240e-20 1.505549017542003453e-20 2.072017792040069654e-20 6.679968263998369730e-20 9.565232418712732609e-20 7.415750100207524471e-20 0.000000000000000000e+00 5.052278030050215110e-20 1.717713093739929099e-19 2.180000000000000071e+01 4.006022093615316304e-19 4.423811849772347791e-20 3.506471821306193457e-20 2.004587395326275486e-20 2.697204823889835334e-20 5.194309637473055416e-20 1.491817989296248595e-20 2.053268621859871126e-20 5.219263507304724520e-20 7.910565918915838698e-20 7.052142465341230374e-20 0.000000000000000000e+00 5.026782992839379552e-20 1.553705413792227780e-19 2.190000000000000213e+01 4.014978317380388147e-19 4.395992598576408129e-20 3.410395346565389303e-20 1.962015748872196975e-20 2.682403869217613812e-20 5.090544179473103462e-20 1.478086961050492833e-20 2.034520260929536587e-20 5.712854132543992735e-20 7.815432225836369623e-20 6.692189830033552655e-20 0.000000000000000000e+00 5.001867840109515101e-20 1.541946066794329634e-19 2.200000000000000000e+01 3.622500541367881306e-19 4.368256683909228373e-20 3.331677432106151135e-20 1.920804106898012758e-20 2.667930123829999908e-20 4.986831015063785789e-20 1.464355932804737674e-20 2.015772731829155604e-20 5.109206039555437351e-20 8.112573915055640070e-20 6.336472365275385177e-20 0.000000000000000000e+00 4.977000919257825426e-20 1.512959035056898842e-19 2.210000000000000142e+01 3.643722691720471433e-19 4.340605703300343810e-20 3.400580002990655323e-20 1.880388012666885188e-20 2.653674334076270861e-20 4.883173476219049109e-20 1.450624904558982213e-20 1.997026057985696689e-20 6.237877136783861389e-20 7.155865582529496695e-20 6.060168130306809136e-20 0.000000000000000000e+00 4.953271023075465508e-20 1.490967848986342895e-19 2.220000000000000284e+01 3.699190938357654855e-19 4.313041290291113249e-20 3.474298553028235249e-20 1.841287499631422535e-20 2.639645925675663500e-20 4.779575182096093886e-20 1.436893876313226452e-20 1.978680961076371482e-20 5.103726338301329702e-20 7.650012901842952416e-20 5.787587341043030342e-20 0.000000000000000000e+00 4.929541126893105590e-20 1.456786154663590503e-19 2.230000000000000071e+01 3.589274576805483045e-19 4.286438500665502446e-20 3.423653205802627604e-20 1.802917076811486331e-20 2.625930982024474959e-20 4.681756538462842546e-20 1.423599545882188345e-20 1.961542156310837274e-20 5.192274816922534256e-20 6.804805376693574264e-20 5.519170392793635642e-20 0.000000000000000000e+00 4.906400611025804555e-20 1.399404195202210735e-19 2.240000000000000213e+01 3.877034143214060821e-19 4.262593246889927940e-20 3.253450311757363799e-20 1.765719343692176796e-20 2.612428190351810072e-20 4.601530467885648238e-20 1.411645844797476124e-20 1.944404127464521492e-20 4.771028301124560167e-20 6.115026556779225969e-20 5.251902895966132322e-20 0.000000000000000000e+00 4.883870788329453065e-20 1.331298834840833768e-19 2.250000000000000000e+01 4.348457595074203813e-19 4.238817342331886853e-20 3.087330597763257318e-20 1.729378723520744678e-20 2.599136666246189898e-20 4.521335612652818910e-20 1.399692143712764505e-20 1.927266895236779318e-20 4.991682180681511620e-20 5.892898643821044649e-20 4.989728001684908908e-20 0.000000000000000000e+00 4.861340965633102779e-20 1.309712118367399935e-19 2.260000000000000142e+01 3.506223597659511410e-19 4.215111960512239825e-20 2.843594390348613164e-20 1.693949140359481845e-20 2.586054153307766172e-20 4.441173663743367892e-20 1.387738442628052285e-20 1.910130481068820602e-20 5.240469238627659594e-20 5.174656958784445114e-20 4.731191955113931479e-20 0.000000000000000000e+00 4.839884742288053934e-20 1.267899963477760302e-19 2.270000000000000284e+01 3.609641582196220887e-19 4.191478297979240915e-20 2.602535354487987511e-20 1.659373337740145571e-20 2.573223825599609776e-20 4.361046435746254524e-20 1.375784741543340064e-20 1.892994217948807188e-20 5.612993958121082116e-20 5.328848602287487443e-20 4.474165629037080565e-20 0.000000000000000000e+00 4.818532118587288749e-20 1.270237602015200127e-19 2.280000000000000071e+01 3.517513036904381738e-19 4.167917574759176915e-20 2.620927263124469019e-20 1.625747021014443017e-20 2.560605050546443277e-20 4.280955878289908106e-20 1.363831040458628144e-20 1.875859445866753766e-20 5.770531620495975889e-20 5.259729789727705668e-20 4.220978327640046365e-20 0.000000000000000000e+00 4.797497349827835502e-20 1.260723787105378478e-19 2.290000000000000213e+01 3.372709900991050782e-19 4.144431034812826596e-20 2.899315433297878816e-20 1.592735330520454136e-20 2.548213633628678330e-20 4.200904088754832236e-20 1.351877339373915923e-20 1.859774870371369499e-20 5.635300730884482920e-20 5.735512345134925119e-20 3.970905082633121619e-20 0.000000000000000000e+00 4.777193840759997480e-20 1.268025439681917251e-19 2.300000000000000000e+01 3.317009182406106247e-19 4.121019946497572549e-20 3.174026036148468407e-20 1.560621419629521026e-20 2.535993495990595091e-20 4.120893326439256508e-20 1.339923638289204154e-20 1.844026475940629244e-20 5.671481274350895630e-20 4.306818488808237451e-20 3.724308181000463049e-20 0.000000000000000000e+00 4.756890331692160661e-20 1.205464649455415286e-19 2.310000000000000142e+01 3.254494987458265462e-19 4.097685603034941743e-20 3.245023348761131732e-20 1.529505843530290216e-20 2.524052076423232315e-20 4.040926028373753759e-20 1.327969937204491933e-20 1.828278870460708055e-20 6.010069738951234220e-20 4.096711525952570760e-20 3.542973514207113469e-20 0.000000000000000000e+00 4.737290607507020951e-20 1.205674869152427517e-19 2.320000000000000284e+01 3.461492225156213482e-19 4.074429322983361144e-20 3.309445733890358150e-20 1.498889036223304192e-20 2.512208142112947262e-20 3.961004827011413372e-20 1.316016236119779713e-20 1.812532074495247450e-20 6.053858267705554421e-20 4.362175595627834136e-20 3.365433948713541408e-20 0.000000000000000000e+00 4.718047474258072670e-20 1.208643402518865162e-19 2.330000000000000071e+01 3.258137407182280774e-19 4.051252450715865976e-20 3.290969770160028559e-20 1.469091758258320884e-20 2.500635076831956308e-20 3.881132570055980984e-20 1.304062535035067943e-20 1.796786109327681187e-20 6.234060302110865425e-20 4.232702814414814048e-20 3.196293556537107431e-20 0.000000000000000000e+00 4.698804341009124991e-20 1.203000748019984591e-19 2.340000000000000213e+01 3.401215899972196999e-19 4.030283521508750718e-20 3.188491621097309131e-20 1.439968343122771794e-20 2.489184523806615100e-20 3.814027704793809067e-20 1.293210012398160283e-20 1.781040996992955337e-20 6.361492096977035364e-20 4.141620309692816302e-20 3.032025504588674462e-20 0.000000000000000000e+00 4.672409048140547456e-20 1.194640968950760491e-19 2.350000000000000000e+01 3.738541690262939915e-19 4.010241406049262953e-20 3.084349096705789917e-20 1.411587617128422933e-20 2.477969154458395738e-20 3.752102578923962498e-20 1.282803583464710511e-20 1.765398635576575100e-20 6.327782416481771994e-20 3.961567067616347583e-20 2.870338748204839574e-20 0.000000000000000000e+00 4.645969561967130211e-20 1.175276005869098783e-19 2.360000000000000142e+01 3.540180221796580165e-19 3.990262483483791838e-20 2.924894730519554322e-20 1.383791557017937199e-20 2.466855694105313671e-20 3.690203073766818335e-20 1.272397154531260438e-20 1.750995028402711763e-20 6.769895051295638350e-20 3.560431651976900684e-20 2.705938085240908762e-20 0.000000000000000000e+00 4.619248123534656992e-20 1.174511572937505716e-19 2.370000000000000284e+01 3.216652769970186329e-19 3.970347707778726902e-20 2.764996712491809798e-20 1.356953706052854760e-20 2.456037566056657067e-20 3.628330500594650053e-20 1.261990725597810365e-20 1.736592192559905589e-20 6.756183145373169039e-20 3.305545082681163058e-20 2.545715099832845313e-20 0.000000000000000000e+00 4.591846535383203066e-20 1.154096295136573481e-19 2.380000000000000071e+01 3.264005856058568308e-19 3.950498049042503484e-20 2.572031931442564382e-20 1.330527113620199934e-20 2.445326307560699673e-20 3.566486261082455402e-20 1.251584296664360593e-20 1.722190147400296980e-20 7.232443875540219872e-20 3.441605674851395134e-20 2.382949635179279087e-20 0.000000000000000000e+00 4.564444947231750344e-20 1.174263315114817880e-19 2.390000000000000213e+01 3.314930463508300261e-19 3.930714493774984781e-20 2.346373560347911081e-20 1.304776702301494828e-20 2.434782467259857700e-20 3.504671855177245369e-20 1.241177867730910520e-20 1.707788912927741771e-20 7.360137435484887226e-20 3.028045045038822388e-20 2.226566425333693841e-20 0.000000000000000000e+00 4.537546176718685181e-20 1.158507603433143426e-19 2.400000000000000000e+01 3.187743532723631436e-19 3.910998045117912789e-20 2.130485736397346889e-20 1.279569758389988007e-20 2.424419429082328579e-20 3.442888889797383076e-20 1.230771438797460899e-20 1.693388509825435086e-20 7.666337702597799597e-20 3.082905332077148940e-20 2.071086642015111050e-20 0.000000000000000000e+00 4.511040951804062744e-20 1.168339675814676747e-19 2.410000000000000142e+01 3.330549540986939866e-19 3.891349723106214472e-20 2.130967952640339199e-20 1.254976990661113664e-20 2.414187305664254283e-20 3.381139088465025491e-20 1.220365009864010826e-20 1.678988212703764113e-20 7.724693067570482066e-20 3.527867868080878715e-20 1.985633074037789794e-20 0.000000000000000000e+00 4.484535726889439705e-20 1.178973377397184869e-19 2.420000000000000284e+01 3.117428902497156277e-19 3.871770564919977199e-20 2.142470779336321966e-20 1.230764406064118806e-20 2.404068952766886707e-20 3.319424301989589060e-20 1.209958580930560753e-20 1.664822277612955157e-20 8.236316043535748736e-20 2.993373278545640773e-20 1.907632800024678637e-20 0.000000000000000000e+00 4.458715141346793341e-20 1.193506249442986130e-19 2.430000000000000071e+01 2.938070768413104584e-19 3.852261625136848479e-20 2.231170686246565483e-20 1.207525920273054991e-20 2.394127902038818711e-20 3.257746520337208401e-20 1.199552151997110981e-20 1.651596271776195829e-20 9.127902673018627407e-20 3.264885895410892875e-20 1.824712245185439384e-20 0.000000000000000000e+00 4.433068743831544398e-20 1.259949911320345337e-19 2.440000000000000213e+01 3.059641457561060392e-19 3.832823975984614455e-20 2.394743589581539430e-20 1.184481175422991392e-20 2.384399548756884064e-20 3.196107885841217021e-20 1.189145723063660909e-20 1.638371041442604106e-20 9.476673118522697415e-20 2.498773214227992574e-20 1.747707464345439903e-20 0.000000000000000000e+00 4.407423357833650387e-20 1.266326139663092390e-19 2.450000000000000000e+01 3.439616817855290448e-19 3.815162206727149338e-20 2.552126227346609875e-20 1.162058816738726293e-20 2.374735838716554075e-20 3.143787555790362094e-20 1.179654609384893201e-20 1.625146605545010533e-20 9.746335480113186887e-20 2.899097241038071094e-20 1.668537381958998933e-20 0.000000000000000000e+00 4.382515146493504223e-20 1.293680504345032515e-19 2.460000000000000142e+01 3.108027513068171056e-19 3.798362353164723030e-20 2.558243732715726535e-20 1.140158550051084996e-20 2.365280983541063181e-20 3.095865541269106055e-20 1.170595175626302293e-20 1.611922983636397806e-20 1.047035380044787479e-19 2.915424865588294164e-20 1.587627090322589464e-20 0.000000000000000000e+00 4.357606935153356854e-20 1.345574094076326895e-19 2.470000000000000284e+01 3.090872778203411775e-19 3.781618938244896708e-20 2.564152571465637200e-20 1.118789845609911708e-20 2.355916274402617830e-20 3.047963836887315636e-20 1.161535741867711385e-20 1.598700195915455151e-20 1.191067550918145215e-19 3.085808714890940105e-20 1.508327113446280152e-20 0.000000000000000000e+00 4.332826389344627513e-20 1.460504999213561496e-19 2.480000000000000071e+01 3.304551249038141897e-19 3.764932714949815176e-20 2.513347513561431455e-20 1.097969326728857112e-20 2.346752454572085618e-20 3.000083415508397344e-20 1.152476308109120928e-20 1.585478263253399613e-20 1.378487070402358489e-19 3.022131903371616770e-20 1.431591822477534304e-20 0.000000000000000000e+00 4.308655469435441684e-20 1.611883277194777312e-19 2.490000000000000213e+01 3.264872350802786296e-19 3.748304447074681077e-20 2.414961391623279249e-20 1.077515987752739287e-20 2.337669304853034379e-20 2.952225312662378204e-20 1.143416874350530020e-20 1.572390560404097787e-20 1.456153888864863593e-19 2.714114095105053491e-20 1.352988140379059149e-20 0.000000000000000000e+00 4.284484549526254651e-20 1.669117211712340235e-19 2.500000000000000000e+01 3.151479969818217670e-19 3.731734909351653579e-20 2.341538673603094199e-20 1.057493418323112304e-20 2.328714836537765187e-20 2.904390631633546427e-20 1.134357440591939413e-20 1.560281474870207728e-20 1.559846764209182395e-19 2.452137531160848241e-20 1.273412413303660509e-20 0.000000000000000000e+00 4.260531083178471219e-20 1.752727758314250552e-19 2.510000000000000142e+01 3.081406486530976033e-19 3.715224887572928536e-20 2.409123527112289193e-20 1.037964637050509819e-20 2.319853486090293318e-20 2.856580549047622327e-20 1.125298006833348656e-20 1.548173161005297599e-20 1.864021191036519645e-19 2.175255399795515373e-20 1.215725973079082785e-20 0.000000000000000000e+00 4.237056779022519820e-20 2.023632691474906003e-19 2.520000000000000284e+01 3.334627025365625163e-19 3.698775178712850877e-20 2.486609706492074726e-20 1.018863872941209438e-20 2.311199396638980138e-20 2.808796321016173590e-20 1.116238573074757748e-20 1.536065637057825960e-20 2.168018741034613853e-19 2.000354587944937416e-20 1.156353104867228510e-20 0.000000000000000000e+00 4.213582474866568420e-20 2.304044464121510628e-19 2.530000000000000071e+01 3.390384581810806811e-19 3.682386591048909946e-20 2.483729261215947140e-20 1.000198071160772579e-20 2.302637741051048724e-20 2.761039289903543474e-20 1.107179139316167141e-20 1.523958921854962927e-20 2.013450720495129513e-19 2.188242068477368825e-20 1.099586222293110311e-20 0.000000000000000000e+00 4.190351538806927523e-20 2.159069180955026522e-19 2.540000000000000213e+01 3.174644206206506455e-19 3.666059944281442672e-20 2.390314132659041458e-20 9.820755671200743097e-21 2.294205698020777490e-20 2.713310891790397488e-20 1.098119705557576383e-20 1.511852642674169425e-20 2.046410468869420840e-19 2.101641224557670292e-20 1.037739735629132164e-20 0.000000000000000000e+00 4.167459458732669651e-20 2.186037898377572220e-19 2.550000000000000000e+01 3.295639852825127271e-19 3.649796069651895296e-20 2.294621800583419195e-20 9.642530633120367474e-21 2.285803930434199599e-20 2.665612664718192539e-20 1.089060271798985776e-20 1.499747057166818646e-20 1.470549258084159675e-19 2.104384003439912498e-20 9.716197674418422267e-21 0.000000000000000000e+00 4.144567378658412380e-20 1.655545820367095208e-19 2.560000000000000142e+01 3.166826958666740188e-19 3.633859406924687643e-20 2.185327647894552839e-20 9.467305597786997830e-21 2.277580975624465794e-20 2.619260323680447459e-20 1.080148178117556386e-20 1.487642879661730485e-20 1.928877824710629314e-19 1.603194184717661651e-20 9.149580790584753526e-21 0.000000000000000000e+00 4.121958551118348140e-20 2.065815769816185441e-19 2.570000000000000284e+01 3.967770606046759790e-19 3.619812719791235167e-20 2.097007460126593225e-20 9.295985749954077089e-21 2.269453837981388934e-20 2.582075132512154353e-20 1.072261386159319657e-20 1.476363249716663883e-20 3.087900227220637689e-19 2.162641226941785087e-20 8.527280549075108928e-21 0.000000000000000000e+00 4.099644194385042423e-20 3.176846848090771187e-19 2.580000000000000071e+01 2.739917359342067494e-19 3.605815529258786455e-20 2.081521336880246239e-20 9.129467200164133079e-21 2.261523446110560702e-20 2.544905546667253605e-20 1.064374594201083078e-20 1.465248212818562718e-20 2.062642275042229139e-19 1.908720940826849074e-20 7.962463557255572221e-21 0.000000000000000000e+00 4.077329837651737309e-20 2.189497989344441481e-19 2.590000000000000213e+01 2.181034927132738538e-19 3.591868413978892664e-20 2.125139322194320481e-20 8.965990627428283769e-21 2.253573970498938536e-20 2.507752260046211745e-20 1.056487802242846348e-20 1.454133961729150590e-20 5.994868310974086509e-20 1.606154685303500016e-20 7.381652835796791596e-21 0.000000000000000000e+00 4.055297587666117545e-20 9.398309436492446538e-20 2.600000000000000000e+01 2.127364089393451512e-19 3.577971959539188171e-20 2.171605221509914852e-20 8.806527305978546542e-21 2.245789309546833855e-20 2.470616007975551162e-20 1.048601010284609920e-20 1.443020514605499483e-20 5.224353224732625217e-20 1.654609454767001334e-20 6.821238800810244289e-21 0.000000000000000000e+00 4.033516867831117706e-20 8.910041389060035171e-20 2.610000000000000142e+01 2.116530086836240745e-19 3.564126758516336796e-20 2.186080141200744570e-20 8.650654109515490816e-21 2.238090649650156010e-20 2.433497570319774623e-20 1.040714218326373190e-20 1.431907890167033962e-20 5.170012891228021133e-20 1.502810103295618368e-20 6.598472591456280701e-21 0.000000000000000000e+00 4.011736147996117867e-20 8.821087653984299574e-20 2.620000000000000284e+01 1.997120591736911430e-19 3.550333410527758672e-20 2.199258128040294086e-20 8.497532134220787418e-21 2.230535628541060317e-20 2.396397774875548381e-20 1.032827426368136460e-20 1.420796107717421181e-20 6.066924077809859092e-20 1.704783729066391647e-20 6.345744983731872903e-21 0.000000000000000000e+00 3.988471454341912989e-20 9.380380290065496714e-20 2.630000000000000071e+01 2.324778480567053653e-19 3.536592522282033033e-20 2.136670961765109865e-20 8.347093086990869571e-21 2.223038936174351830e-20 2.359317501078172706e-20 1.024940634409899881e-20 1.409685187167483725e-20 2.319159116940062218e-19 1.663950623417984470e-20 6.123289510250367447e-21 0.000000000000000000e+00 3.963904864741134310e-20 2.424915889423674972e-19 2.640000000000000213e+01 3.436685192204614471e-19 3.522904707627889056e-20 2.001925733401069630e-20 8.200265443178607965e-21 2.215608909286045694e-20 2.322257684054046035e-20 1.017053842451663152e-20 1.398892396392883039e-20 3.859102119890072561e-19 1.933177464881875229e-20 5.846364205885896148e-21 0.000000000000000000e+00 3.939338275140355029e-20 3.923325614672646682e-19 2.650000000000000000e+01 3.168805840997168403e-19 3.509270587601690870e-20 1.877424775075653965e-20 8.056650965434811486e-21 2.208286079033507570e-20 2.285219319057015109e-20 1.009167050493426723e-20 1.388730423455575691e-20 2.111920800734487089e-19 1.571853638065057101e-20 5.623942851841962588e-21 0.000000000000000000e+00 3.914983834241808792e-20 2.221867686497376837e-19 2.660000000000000142e+01 2.424062282940068470e-19 3.495690790473309593e-20 1.941667908369389736e-20 7.917296729689627193e-21 2.201178236536732785e-20 2.248203466331236436e-20 1.001280258535189993e-20 1.378569222817074008e-20 1.445389072511497664e-19 1.304731552169349619e-20 5.431028654869970146e-21 0.000000000000000000e+00 3.890839866975760791e-20 1.598343708552849681e-19 2.670000000000000284e+01 2.248268915756100278e-19 3.482165951790284309e-20 2.009481187537452910e-20 7.779390802468791426e-21 2.193969767693113855e-20 2.211211256448645882e-20 9.933934665769532638e-21 1.368408811681629533e-20 1.328317345983884120e-19 1.332234590223902803e-20 5.240266362772047059e-21 0.000000000000000000e+00 3.866695899709712789e-20 1.492563240378403783e-19 2.680000000000000071e+01 1.923109363473916764e-19 3.468741031249587928e-20 2.051228829810446727e-20 7.644933643138525860e-21 2.187005072572368598e-20 2.174447784462727795e-20 9.855325954593469291e-21 1.358248870866469301e-20 1.312678313690396594e-19 1.306022981440513244e-20 5.005658323394595167e-21 0.000000000000000000e+00 3.842842070684113948e-20 1.477117516953263488e-19 2.690000000000000213e+01 2.000057193166190818e-19 3.457066420576808941e-20 2.067444800488782784e-20 7.512686008305918582e-21 2.180001053525419144e-20 2.145528868138956053e-20 9.786666600101778659e-21 1.348089384919676661e-20 1.081313678038820579e-19 1.351054937755356811e-20 4.796678373326530794e-21 0.000000000000000000e+00 3.819363320778961103e-20 1.274706894838889580e-19 2.700000000000000000e+01 1.870268457891850616e-19 3.445434949503891106e-20 2.079354610044258029e-20 7.384103808598030403e-21 2.173136088979008142e-20 2.116622117936966038e-20 9.718007245610091036e-21 1.337931442820908368e-20 1.105369729857009936e-19 1.147871110977789439e-20 4.634836158761143554e-21 0.000000000000000000e+00 3.795884570873808860e-20 1.291520201602989330e-19 2.710000000000000142e+01 1.795151085008122643e-19 3.433847056411195538e-20 1.948854462392352185e-20 7.257873206418816147e-21 2.166376974536520746e-20 2.087728039214368129e-20 9.649347891118401909e-21 1.327774364252695886e-20 1.008706922305471670e-19 1.019679254333015133e-20 4.632928436239486464e-21 0.000000000000000000e+00 3.772598355900838267e-20 1.204565639285205237e-19 2.720000000000000284e+01 1.842031725015020904e-19 3.422303183962901646e-20 1.830747430476769700e-20 7.134232810400850327e-21 2.159716734080167529e-20 2.058847165469876656e-20 9.580688536626711277e-21 1.318115972971048244e-20 9.338664696435867835e-20 1.212428629759265282e-20 4.631289506997833998e-21 0.000000000000000000e+00 3.749694692494188943e-20 1.140555399314263738e-19 2.730000000000000071e+01 2.588468770722266721e-19 3.410803779122924337e-20 1.747417385747860928e-20 7.013299063393211368e-21 2.153110298355574395e-20 2.029980060312019556e-20 9.512029182135023654e-21 1.308768463198708706e-20 1.230970226464482679e-19 1.226456298550253588e-20 4.631026398893520800e-21 0.000000000000000000e+00 3.726791029087540822e-20 1.391724393647194342e-19 2.740000000000000213e+01 5.213717754171743410e-19 3.399349293169747288e-20 1.690285962039411394e-20 6.894111856129085044e-21 2.146562797826382514e-20 2.001127319593884271e-20 9.443369827643333022e-21 1.299421735032781231e-20 2.457987191119053702e-19 1.465846771582601525e-20 4.617607064276896245e-21 0.000000000000000000e+00 3.704001536483972113e-20 2.542306240150047847e-19 2.750000000000000000e+01 5.368207660204330950e-19 3.387940181710107885e-20 1.641278531037435778e-20 6.778565734390212087e-21 2.140116483410567201e-20 1.972289573730284704e-20 9.374710473151645400e-21 1.290075805461716162e-20 2.161327789052741394e-19 1.095378241612980797e-20 4.581390904980334513e-21 0.000000000000000000e+00 3.681676005176872358e-20 2.253315024575448180e-19 2.760000000000000142e+01 3.284716995455099825e-19 3.376576904691497106e-20 1.624683377981861289e-20 6.664474625455179404e-21 2.133717768359388681e-20 1.943467490215603470e-20 9.306051118659956273e-21 1.280730691968372326e-20 1.384743340219671143e-19 1.788668459392934870e-20 4.614285979491429303e-21 0.000000000000000000e+00 3.659350473869772603e-20 1.529299327142841679e-19 2.770000000000000284e+01 4.493016556664505450e-19 3.365259926413400334e-20 1.626644597798766972e-20 6.552905944223057167e-21 2.127456151748427400e-20 1.914661776362670409e-20 9.237391764168265641e-21 1.271386412548078499e-20 1.582985857236303539e-19 1.253863566062945420e-20 4.666707276282872288e-21 0.000000000000000000e+00 3.637037896132728400e-20 1.704888536367677335e-19 2.780000000000000071e+01 3.298498533637281078e-19 3.353989715537253814e-20 1.644101397163113403e-20 6.443673751044853816e-21 2.121237923852049086e-20 1.885873182285370242e-20 9.168732409676578018e-21 1.262042985727490661e-20 1.124569081860827974e-19 9.936480785889126952e-21 4.738562509372222537e-21 0.000000000000000000e+00 3.615256483955417596e-20 1.286874587675147746e-19 2.790000000000000213e+01 1.624575294689230815e-19 3.342766745095032491e-20 1.683349464088598500e-20 6.336450179104086411e-21 2.115049522174362915e-20 1.857102504150379083e-20 9.100073055184888891e-21 1.252700430584280877e-20 6.732562076744201254e-20 1.043686396214042107e-20 4.761615513464097935e-21 0.000000000000000000e+00 3.593475071778106191e-20 9.180706025217544200e-20 2.800000000000000000e+01 1.527407748038490307e-19 3.331591492496437344e-20 1.725176883220734213e-20 6.231981988944965320e-21 2.108910836227456081e-20 1.828350587726445682e-20 9.031413700693201268e-21 1.243902990131435652e-20 6.814450578402274454e-20 8.524382408429003138e-21 4.818845934219874249e-21 0.000000000000000000e+00 3.571693659600795388e-20 9.207064619937966953e-20 2.810000000000000142e+01 2.879793465361987955e-19 3.320973812695171035e-20 1.668879921034556348e-20 6.129041072139703450e-21 2.102975451195257431e-20 1.801801029928714202e-20 8.965890769021767421e-21 1.235372599636680115e-20 1.321268301058544120e-19 1.326278205610811097e-20 4.879949341655059186e-21 0.000000000000000000e+00 3.550287847935172261e-20 1.460703179665442307e-19 2.820000000000000284e+01 6.040679469608817140e-19 3.311330816197867306e-20 1.607978039391849036e-20 6.027913792024143145e-21 2.096984974949621045e-20 1.779266355277114665e-20 8.906118595694787596e-21 1.226842615361392202e-20 2.285139286320967489e-19 2.481360193501945464e-20 4.945199698125122818e-21 0.000000000000000000e+00 3.528968233408269752e-20 2.376587470772665009e-19 2.830000000000000071e+01 3.850341936514778669e-19 3.301725099578411122e-20 1.582733057454396528e-20 5.929317002581381811e-21 2.091100951393437716e-20 1.756741261198307142e-20 8.846346422367809276e-21 1.218313004594353420e-20 1.548529099317928021e-19 1.769164714740594772e-20 4.981653252545857108e-21 0.000000000000000000e+00 3.507648618881368446e-20 1.670208541161220491e-19 2.840000000000000213e+01 1.570369176784274865e-19 3.292156989157777800e-20 1.600234140074430213e-20 5.832499018443422072e-21 2.085298392884192747e-20 1.734226121005765298e-20 8.786574249040829450e-21 1.209784980489999660e-20 5.941452794258834274e-20 9.397397828019768182e-21 5.050326854350335353e-21 0.000000000000000000e+00 3.486591772873416479e-20 8.480932021755456512e-20 2.850000000000000000e+01 1.926622456203947956e-19 3.282626813776527261e-20 1.629457324471101801e-20 5.737369024725148814e-21 2.079498458740444939e-20 1.711721327485103682e-20 8.726802075713851130e-21 1.201257781577887020e-20 5.414459553960968113e-20 7.812003785398027394e-21 5.105068351323669510e-21 0.000000000000000000e+00 3.465736685022306248e-20 8.088104415804215185e-20 2.860000000000000142e+01 1.596140577278306575e-19 3.273134904793684592e-20 1.706506983196017611e-20 5.644720129854120001e-21 2.073844554877153404e-20 1.689227294168135154e-20 8.667029902386871305e-21 1.192731425556663793e-20 5.460291357089633553e-20 9.452969088223088859e-21 5.176041580181625504e-21 0.000000000000000000e+00 3.444881597171195416e-20 8.131162308743928041e-20 2.870000000000000284e+01 1.416807464077651639e-19 3.263681596084824945e-20 1.786839328653647148e-20 5.553537902036858583e-21 2.068235030931428656e-20 1.666744456707269260e-20 8.607257729059891480e-21 1.184205930632930258e-20 5.364200836860337731e-20 8.528692568365675919e-21 5.226732685026759124e-21 0.000000000000000000e+00 3.424147500763905800e-20 8.053053209112184182e-20 2.880000000000000071e+01 1.422313880277318880e-19 3.254267224039340520e-20 1.757391327353419194e-20 5.463991230058944518e-21 2.062604442256665407e-20 1.644273274359465328e-20 8.547485555732913159e-21 1.176016763018777208e-20 5.324930985708470237e-20 8.798830093559642939e-21 5.303770656181206314e-21 0.000000000000000000e+00 3.403723985360304586e-20 8.002782926185307024e-20 2.890000000000000213e+01 1.358032942137868942e-19 3.244892127556867972e-20 1.617086873108871323e-20 5.376435278745799820e-21 2.057110816652151437e-20 1.621814231589968181e-20 8.487713382405933334e-21 1.168171717580631814e-20 4.918089712186204535e-20 7.903691007739240004e-21 5.373457091340011415e-21 0.000000000000000000e+00 3.383300469956702167e-20 7.676466108280552656e-20 2.900000000000000000e+01 1.395108014226002617e-19 3.235556648042846727e-20 1.479202461476707996e-20 5.290593515744018898e-21 2.051690767613268445e-20 1.599367839807121724e-20 8.427941209078956518e-21 1.160327448538494382e-20 4.866971699510205892e-20 7.854041936851084616e-21 5.427125217388376832e-21 0.000000000000000000e+00 3.362876954553100350e-20 7.593984218920710625e-20 2.910000000000000142e+01 1.360801026009547982e-19 3.226261129403179347e-20 1.384097815120644412e-20 5.205899005708856017e-21 2.046303389080953256e-20 1.576934639240767850e-20 8.368169035751976693e-21 1.152483971745754149e-20 5.049651157249461823e-20 8.533116335253277255e-21 5.394542183200830956e-21 0.000000000000000000e+00 3.342797228278143657e-20 7.680526378459066485e-20 2.920000000000000284e+01 1.443089978319293712e-19 3.217005918037981281e-20 1.290787636074459969e-20 5.123495752453983531e-21 2.040958992373571316e-20 1.554515200978137347e-20 8.308396862424995363e-21 1.144641303488709228e-20 4.666999720151582454e-20 7.559385641477275853e-21 5.368672622086820134e-21 0.000000000000000000e+00 3.322732967703117743e-20 7.385215070290913235e-20 2.930000000000000071e+01 1.454967377890851517e-19 3.207791362834374281e-20 1.301568030239020352e-20 5.041740755568964415e-21 2.035687494562016182e-20 1.532110129172627635e-20 8.248624689098018547e-21 1.136799460501386189e-20 4.558367246463557965e-20 7.831372699211702400e-21 5.360611046929181100e-21 0.000000000000000000e+00 3.302668707128092430e-20 7.299951398940926666e-20 2.940000000000000213e+01 1.406767044763136859e-19 3.198714504982851051e-20 1.416957208691721390e-20 4.962787189125786928e-21 2.030463379227483893e-20 1.510105397780776279e-20 8.189480438389140919e-21 1.128958459980968867e-20 4.418283414643058595e-20 6.244487859047361819e-21 5.335691518909238767e-21 0.000000000000000000e+00 3.282919764083732654e-20 7.197755245057054985e-20 2.950000000000000000e+01 1.787132482098043675e-19 3.190768269904442494e-20 1.528197053309066874e-20 4.884640948895993411e-21 2.025272991054406947e-20 1.492474094464213111e-20 8.137445100587315102e-21 1.121118319603870843e-20 4.454862723122678993e-20 7.833401260473545031e-21 5.328452111028693283e-21 0.000000000000000000e+00 3.263385423040543908e-20 7.238529799369749705e-20 2.960000000000000142e+01 1.526461158948945856e-19 3.182853688302644287e-20 1.503369608932361473e-20 4.808262450773885094e-21 2.020140380584852300e-20 1.474850080139294660e-20 8.085409762785486276e-21 1.113330847471790230e-20 4.546083335775156489e-20 7.991961125844117402e-21 5.286910192820753276e-21 0.000000000000000000e+00 3.243851081997354559e-20 7.271790551218872404e-20 2.970000000000000284e+01 1.477957939686119591e-19 3.174970996895239833e-20 1.477146660545772014e-20 4.733174275391390160e-21 2.015040214165855084e-20 1.457233619268705969e-20 8.033374424983658955e-21 1.106167724424067968e-20 4.746312887330897719e-20 7.874313722487151026e-21 5.265199077519887527e-21 0.000000000000000000e+00 3.224419639982867682e-20 7.372987648193972445e-20 2.980000000000000071e+01 1.849028241922340000e-19 3.167120433798123324e-20 1.469008965015069176e-20 4.659126960401357854e-21 2.009996910381140687e-20 1.439624989143714427e-20 7.981339087181833139e-21 1.099006011349034473e-20 4.442507801756354907e-20 8.423655580522294843e-21 5.232683711929343992e-21 0.000000000000000000e+00 3.205415326177770000e-20 7.166387232336002756e-20 2.990000000000000213e+01 1.477481881388573839e-19 3.159302238518612547e-20 1.479737078419696449e-20 4.586727735264410825e-21 2.005076615235553129e-20 1.422024480663776280e-20 7.929303749380005818e-21 1.091845076686387326e-20 4.334946111285294130e-20 8.142351515578069850e-21 5.211833448987874499e-21 0.000000000000000000e+00 3.186411012372671717e-20 7.079839487222713218e-20 3.000000000000000000e+01 1.324037766189156181e-19 3.151516651948277809e-20 1.498320602343895395e-20 4.516012838793337964e-21 2.000146851840855931e-20 1.404432399173098004e-20 7.877268411578180001e-21 1.084684935853028266e-20 4.515597657440523981e-20 7.461183387739266452e-21 5.184879521398342024e-21 0.000000000000000000e+00 3.167406698567574035e-20 7.169354787121494254e-20 3.010000000000000142e+01 1.190453574544942994e-19 3.143763916355249049e-20 1.596894149531677020e-20 4.446543227998108512e-21 1.995239113990383229e-20 1.386849065358989039e-20 7.825233073776352680e-21 1.077525604673906563e-20 4.272532474789695535e-20 7.702166168257989119e-21 5.067991324045910699e-21 0.000000000000000000e+00 3.148752755964812178e-20 7.023391646814299615e-20 3.020000000000000284e+01 1.309370024656809883e-19 3.136044275376027624e-20 1.705372791923173591e-20 4.378349541162761884e-21 1.990459326455607249e-20 1.369274816217356950e-20 7.773197735974525359e-21 1.070367099395550478e-20 4.274479360237932772e-20 7.635131303848497599e-21 4.924198524482990156e-21 0.000000000000000000e+00 3.130213230805194070e-20 7.029677190088822040e-20 3.030000000000000071e+01 1.280469855476964977e-19 3.128357974006757637e-20 1.731440669729442717e-20 4.311280064982851828e-21 1.985676316197232621e-20 1.351710006091184651e-20 7.721162398172699542e-21 1.063209436700134078e-20 4.128131710305674005e-20 8.288865086950947211e-21 4.802460673772911613e-21 0.000000000000000000e+00 3.111673705645576564e-20 6.936040926150077498e-20 3.040000000000000213e+01 1.307191478907318454e-19 3.120705258593965821e-20 1.667251110518694830e-20 4.245536904678798685e-21 1.980951660586688740e-20 1.334155007788435390e-20 7.669127060370870717e-21 1.056052633720111443e-20 3.980334566223873896e-20 7.798756806836804542e-21 4.673239921857710202e-21 0.000000000000000000e+00 3.093262743633396446e-20 6.807661139782844488e-20 3.050000000000000000e+01 1.480794454976009475e-19 3.113086376824750136e-20 1.604337254662328883e-20 4.181008393582662354e-21 1.976251593426630738e-20 1.316610213786475318e-20 7.617091722569044900e-21 1.049134087493071647e-20 3.874772831679273578e-20 8.441651367790975428e-21 4.548304252157846553e-21 0.000000000000000000e+00 3.075193040845705759e-20 6.719381769909394206e-20 3.060000000000000142e+01 1.349548747540788536e-19 3.105501577716410433e-20 1.549148383289637264e-20 4.117729224692432822e-21 1.971585880023534825e-20 1.299076037530810806e-20 7.565056384767217579e-21 1.042551694684818030e-20 4.379601112544512704e-20 7.590482605050511083e-21 4.411811972103894603e-21 0.000000000000000000e+00 3.057123338058014469e-20 6.981778145480339445e-20 3.070000000000000284e+01 1.281172612411496435e-19 3.097951111605512190e-20 1.508282808691230794e-20 4.055437555898496323e-21 1.966984671913288517e-20 1.281552914836767018e-20 7.513021046965390258e-21 1.035970073583860115e-20 3.907723670446083905e-20 8.527004070667274170e-21 4.303596888509631857e-21 0.000000000000000000e+00 3.039053635270322578e-20 6.678640430967558967e-20 3.080000000000000071e+01 1.241943477610701850e-19 3.090612976034720378e-20 1.462584956208183572e-20 3.994446239410812848e-21 1.962467481691389537e-20 1.264708575118605717e-20 7.462210106895113084e-21 1.029389238992426914e-20 3.861950412990243574e-20 7.352114973810275684e-21 4.172239650541067541e-21 0.000000000000000000e+00 3.021316663077713612e-20 6.608742761075056734e-20 3.090000000000000213e+01 1.304686840027303661e-19 3.084104751476694280e-20 1.405032083920739583e-20 3.934046718534892342e-21 1.957871406151246202e-20 1.250875651792521151e-20 7.416910158282935870e-21 1.022809206091909777e-20 3.910579379182753500e-20 7.250981325542784452e-21 4.052307022586469747e-21 0.000000000000000000e+00 3.003688765688881094e-20 6.606022675632018979e-20 3.100000000000000000e+01 1.232423736584327000e-19 3.077623165944821924e-20 1.356307524285796204e-20 3.875544539773241516e-21 1.953422779569233383e-20 1.237048309514950704e-20 7.371610209670760160e-21 1.016228724435939482e-20 4.159930195541292643e-20 8.222424245339037338e-21 3.930171722117108158e-21 0.000000000000000000e+00 2.986060868300049178e-20 6.740618147999008569e-20 3.110000000000000142e+01 1.292200026691876594e-19 3.071168388101101334e-20 1.362275762385787346e-20 3.817538192493471127e-21 1.948995555556150059e-20 1.223226737550250375e-20 7.326310261058584450e-21 1.009650213863673945e-20 4.074053571450435397e-20 6.329193831326748651e-21 3.885406202430917052e-21 0.000000000000000000e+00 2.968506441528855834e-20 6.651774902741401482e-20 3.120000000000000284e+01 1.429623257754485507e-19 3.064740587327904771e-20 1.371231161625805583e-20 3.760840046436532472e-21 1.944641215825176058e-20 1.209411133733877012e-20 7.281010312446407236e-21 1.003072671958820080e-20 3.957469795269269770e-20 6.023065400320837633e-21 3.862458805408120956e-21 0.000000000000000000e+00 2.951261637354023300e-20 6.563414589326152515e-20 3.130000000000000071e+01 1.466272097264400271e-19 3.058339933720685473e-20 1.379653387593334398e-20 3.705065759036981519e-21 1.940286603879434127e-20 1.195601704958091892e-20 7.235710363834231526e-21 9.964959963929345884e-21 3.895426941491866459e-20 6.816268564194383079e-21 3.822678223648598512e-21 0.000000000000000000e+00 2.934016833179191367e-20 6.519083240285896693e-20 3.140000000000000213e+01 1.562158406583058906e-19 3.051966598080404539e-20 1.391155408915218369e-20 3.650088206413721996e-21 1.935966255448133679e-20 1.181798667690706640e-20 7.190410415222054312e-21 9.902014594807675241e-21 3.403857761156863096e-20 7.045055271088003448e-21 3.801756318760262133e-21 0.000000000000000000e+00 2.916772029004358832e-20 6.225740565250717737e-20 3.150000000000000000e+01 1.534443612511797551e-19 3.045620751905676143e-20 1.403898003915272167e-20 3.596471556753334396e-21 1.931700679910044081e-20 1.168002248529498580e-20 7.145110466609880106e-21 9.841914599976199727e-21 3.784502359919332294e-20 7.825116986735998943e-21 3.779223774634377357e-21 0.000000000000000000e+00 2.899755978471246315e-20 6.437167840778445827e-20 3.160000000000000142e+01 1.251607891311130428e-19 3.039302567384611827e-20 1.360055063009735055e-20 3.543687716893672754e-21 1.927465400851386833e-20 1.154212684795137604e-20 7.099810517997702892e-21 9.781822268258665765e-21 3.608219249844148097e-20 8.283461278632628979e-21 3.753044103702272770e-21 0.000000000000000000e+00 2.882899438742865832e-20 6.314926483319569542e-20 3.170000000000000284e+01 1.111240742887178014e-19 3.033012217386384318e-20 1.314464163727011944e-20 3.491640038702529968e-21 1.923262358750687046e-20 1.140430225165763842e-20 7.054510569385525678e-21 9.721737741757566379e-21 3.487799115764308524e-20 7.630674137602881851e-21 3.714949210092504407e-21 0.000000000000000000e+00 2.866042899014485951e-20 6.212118947293444293e-20 3.180000000000000071e+01 1.090961515405360109e-19 3.026749875452484417e-20 1.309147493354126018e-20 3.440880037324118833e-21 1.919081521865512058e-20 1.126655130356610722e-20 7.009210620773351473e-21 9.661661166091572418e-21 3.578645399447029569e-20 6.686616520019578400e-21 3.704410099352104537e-21 0.000000000000000000e+00 2.849186359286106069e-20 6.235332568862429123e-20 3.190000000000000213e+01 1.096265129259390492e-19 3.020515715787681759e-20 1.343518316051965749e-20 3.390840036003169519e-21 1.914932324654385588e-20 1.112887673848402207e-20 6.963910672161174258e-21 9.601592690504341576e-21 3.716986371934187255e-20 7.608969337933472572e-21 3.647032219723503131e-21 0.000000000000000000e+00 2.832671865225055609e-20 6.317268073193674811e-20 3.200000000000000000e+01 1.097216318175500762e-19 3.014309913250675632e-20 1.370254668684128760e-20 3.341560034730168686e-21 1.910816727535179862e-20 1.099128142668608837e-20 6.918610723548998548e-21 9.541532467977397447e-21 3.508680377100152393e-20 7.017285467601698572e-21 3.630854950914136680e-21 0.000000000000000000e+00 2.816177355791370383e-20 6.179777719698484666e-20 3.210000000000000142e+01 1.040581185241579230e-19 3.008132643344438243e-20 1.260464604686206992e-20 3.293441221626273158e-21 1.906788684204181312e-20 1.085376838230014326e-20 6.873310774936821334e-21 9.481480655347205003e-21 3.588823553139691004e-20 6.950580457880608415e-21 3.587590455215783584e-21 0.000000000000000000e+00 2.799682846357685158e-20 6.185554750980976061e-20 3.220000000000000284e+01 1.090280204255787858e-19 3.001984082206247427e-20 1.147579611110257084e-20 3.246067359066438189e-21 1.902792878133504002e-20 1.071634077231505648e-20 6.828010826324645624e-21 9.421437413426659155e-21 3.191115344290823572e-20 6.447136476402901253e-21 3.535717943011458214e-21 0.000000000000000000e+00 2.783268335793192879e-20 5.918408390588010834e-20 3.230000000000000426e+01 1.014799398492706471e-19 2.996363311428981208e-20 1.095871868836912042e-20 3.199322011401718086e-21 1.898764804735412878e-20 1.059678843973081875e-20 6.786376266028818893e-21 9.362935288555561512e-21 3.219771586553852392e-20 6.535356689001040638e-21 3.500153011254411884e-21 0.000000000000000000e+00 2.767083677397139458e-20 5.909332214864891516e-20 3.239999999999999858e+01 1.083612100391109670e-19 2.991065128663999816e-20 1.106610054399551375e-20 3.153280822198966575e-21 1.894816084906067284e-20 1.048795370754335238e-20 6.746939886234746952e-21 9.307686332254185827e-21 3.506725984942872884e-20 5.874713056389221229e-21 3.458542996520427412e-21 0.000000000000000000e+00 2.750899019001087240e-20 6.050755361590113721e-20 3.250000000000000000e+01 1.280942445223227805e-19 2.985789150347178704e-20 1.123604003404251791e-20 3.108334146715869605e-21 1.890891530898208944e-20 1.037916180176003076e-20 6.707503506440672001e-21 9.252449479418882944e-21 3.424315701476917097e-20 5.794058861030961232e-21 3.409618982184277529e-21 0.000000000000000000e+00 2.734714360605033819e-20 5.990770576321264648e-20 3.260000000000000142e+01 1.062058130752152113e-19 2.980535494393761682e-20 1.120594920645910155e-20 3.064021988848480810e-21 1.886949134158174327e-20 1.027041408332883853e-20 6.668067126646597050e-21 9.197225736621688842e-21 3.500426945530560337e-20 5.881469442002704945e-21 3.370558503288500277e-21 0.000000000000000000e+00 2.718694272038010238e-20 6.020210115179599059e-20 3.270000000000000284e+01 9.214500303888853056e-20 2.975304279051170333e-20 1.117067436634887785e-20 3.020750318358010604e-21 1.883122311817098772e-20 1.016171197089087563e-20 6.628630746852522100e-21 9.142009944855264114e-21 3.319849289766035056e-20 7.226675673142610539e-21 3.332169664258012516e-21 0.000000000000000000e+00 2.702820804174397673e-20 5.916531970567311550e-20 3.280000000000000426e+01 9.615472453653026655e-20 2.970095622893030628e-20 1.123000325768802980e-20 2.978118861112072978e-21 1.879271279740967044e-20 1.005305694383739039e-20 6.589194367058447149e-21 9.086802249062496371e-21 3.295995411066492385e-20 6.102352437011736057e-21 3.298802781083500905e-21 0.000000000000000000e+00 2.686947336310784807e-20 5.876899191406740528e-20 3.289999999999999858e+01 9.225019378452217343e-20 2.964909644813055685e-20 1.139115623954887939e-20 2.936056724295442614e-21 1.875493212486173682e-20 9.944450545561090834e-21 6.549757987264375208e-21 9.031602797708750940e-21 3.254422673991256095e-20 5.521805013135230121e-21 3.263489834370824042e-21 0.000000000000000000e+00 2.671073868447173145e-20 5.836340887810048416e-20 3.300000000000000000e+01 1.006737263027535635e-19 2.959746464018771453e-20 1.156850944127977181e-20 2.894624102067209016e-21 1.871750856997820485e-20 9.835894386916014639e-21 6.510321607470300257e-21 8.976411742888818664e-21 3.319921148308366462e-20 5.745521054191583835e-21 3.231811419491367182e-21 0.000000000000000000e+00 2.655435138039413329e-20 5.864338164488825328e-20 3.310000000000000142e+01 9.668331863435446269e-20 2.954606200025100356e-20 1.197978825072698386e-20 2.854083100484760985e-21 1.867965454498603954e-20 9.727390149901684150e-21 6.470885227676225306e-21 8.921229240437808838e-21 3.014857498882169492e-20 7.375996846947833804e-21 3.178796741409791389e-21 0.000000000000000000e+00 2.639872059957730666e-20 5.709625467400257954e-20 3.320000000000000284e+01 1.067558321679852889e-19 2.949488972647787251e-20 1.241706415040477932e-20 2.814175407380323083e-21 1.864276775934195072e-20 9.618939591588326150e-21 6.431448847882150356e-21 8.866055450046056506e-21 3.035398994565943932e-20 7.111266120059833938e-21 3.116423797353112846e-21 0.000000000000000000e+00 2.624308981876048303e-20 5.711782138185250858e-20 3.330000000000000426e+01 9.245538552290918637e-20 2.944394901996679738e-20 1.267685748306685291e-20 2.775090307709664262e-21 1.860637471974591774e-20 9.510544548301592628e-21 6.392012468088075405e-21 8.815062784281868288e-21 3.214616922922327822e-20 6.017271790280378394e-21 3.052458828416134972e-21 0.000000000000000000e+00 2.608745903794365640e-20 5.787933611160134374e-20 3.339999999999999858e+01 1.012140847223926384e-19 2.939324108468846574e-20 1.274885720683116490e-20 2.736407713561313574e-21 1.856926415479864898e-20 9.402206940086767080e-21 6.352576088294003464e-21 8.764680838928041753e-21 3.219118081457617751e-20 5.736860499149215657e-21 2.973132883216105682e-21 0.000000000000000000e+00 2.593491010945215113e-20 5.774963723373879820e-20 3.350000000000000000e+01 1.128105969403211703e-19 2.934276712741543811e-20 1.279848365208186353e-20 2.698384020535340930e-21 1.853299703928104558e-20 9.293928775474068903e-21 6.313139708499928513e-21 8.714306558952943555e-21 3.097392989398285941e-20 6.178372108524628736e-21 2.922183586998528209e-21 0.000000000000000000e+00 2.578255801479386459e-20 5.699614439261438936e-20 3.360000000000000142e+01 9.653972291418953986e-20 2.929252835765028672e-20 1.249178044417472057e-20 2.661220397197737976e-21 1.849713795223089536e-20 9.185712156568851625e-21 6.273703328705853562e-21 8.663940078061772925e-21 2.817396363640794425e-20 6.125111982935972832e-21 2.861516084964719393e-21 0.000000000000000000e+00 2.563020592013557806e-20 5.530378355261002945e-20 3.370000000000000284e+01 9.437984191526347442e-20 2.924252598755210327e-20 1.216385529978937503e-20 2.624702660682760989e-21 1.846157631305932261e-20 9.077559284492246667e-21 6.234266948911778612e-21 8.613581533066058492e-21 2.929819198280196323e-20 7.027949609590739020e-21 2.800150765565170945e-21 0.000000000000000000e+00 2.547811945425799404e-20 5.577649203830165348e-20 3.380000000000000426e+01 9.316200045130961833e-20 2.919523523115448411e-20 1.155001189293102748e-20 2.588698886462524553e-21 1.842645060382756868e-20 8.977841479361613745e-21 6.196770600807021368e-21 8.563218495177316725e-21 3.106930430219568306e-20 5.467614002555241084e-21 2.741677062249505703e-21 0.000000000000000000e+00 2.532911157187002391e-20 5.629038507640855342e-20 3.389999999999999858e+01 9.387805067216464991e-20 2.915217936482715720e-20 1.065152542380611734e-20 2.553196999051037628e-21 1.839131197819180396e-20 8.891817475444464533e-21 6.162438816800442092e-21 8.512872280900864883e-21 3.014335378487470026e-20 4.904618647429271133e-21 2.676618749650722981e-21 0.000000000000000000e+00 2.518010368948206281e-20 5.542067991866778328e-20 3.400000000000000000e+01 9.557746600721925499e-20 2.910930596397442540e-20 9.799230069456378532e-21 2.518266559380611454e-21 1.835638475860253773e-20 8.805825294950174407e-21 6.128107032793859807e-21 8.462538298557492663e-21 2.949177519528776215e-20 6.130210558469868390e-21 2.622666250053707401e-21 0.000000000000000000e+00 2.503109580709409569e-20 5.490140583024391020e-20 3.410000000000000142e+01 8.708253624999049094e-20 2.906661583600872013e-20 1.026416939846635153e-20 2.484015343853242369e-21 1.832176327529234530e-20 8.719865879372240322e-21 6.093775248787277521e-21 8.412212831108779516e-21 2.833152193424035937e-20 7.613796989784118931e-21 2.578962153644124588e-21 0.000000000000000000e+00 2.488263276392841138e-20 5.442844525211206177e-20 3.420000000000000284e+01 8.477143506373731096e-20 2.902410978963112459e-20 1.080977513987489100e-20 2.450243380681411301e-21 1.828720690789799460e-20 8.633940207332184036e-21 6.059443464780695989e-21 8.362494459107922537e-21 2.952367176927652461e-20 6.637097946021982085e-21 2.551696646293643025e-21 0.000000000000000000e+00 2.473675352959910953e-20 5.490888182982094587e-20 3.430000000000000426e+01 8.922041373415555927e-20 2.898178863478964726e-20 1.124071470543405656e-20 2.416962978626379588e-21 1.825297817475761463e-20 8.548049296408252690e-21 6.025111680774113703e-21 8.316154442428741035e-21 2.944229177201845335e-20 5.667625117741811542e-21 2.499045416493020135e-21 0.000000000000000000e+00 2.459087429526980767e-20 5.471532737690733865e-20 3.439999999999999858e+01 9.325878754463323605e-20 2.893965318263673108e-20 1.153211093977328026e-20 2.384394459593750462e-21 1.821911385609512411e-20 8.462194205072063238e-21 5.990779896767534427e-21 8.269822038516668027e-21 2.860462750715720656e-20 6.807389482610161203e-21 2.457797351411856810e-21 0.000000000000000000e+00 2.444499506094051786e-20 5.433384308628111322e-20 3.450000000000000000e+01 1.102891406564136342e-19 2.889770424548605843e-20 1.178039335365014206e-20 2.352283347989074638e-21 1.818592875380041921e-20 8.376376034740552912e-21 5.956448112760952142e-21 8.223497376046075812e-21 2.846860631102437398e-20 6.307227239116136149e-21 2.432435860910012268e-21 0.000000000000000000e+00 2.429972645927387874e-20 5.412967013989635594e-20 3.460000000000000142e+01 1.001734441051075709e-19 2.885594263676864600e-20 1.095382304405912879e-20 2.320885151790051567e-21 1.815280471056875645e-20 8.290595931951317093e-21 5.922116328754369857e-21 8.177180586585421083e-21 2.980489676407511372e-20 6.638002417128259128e-21 2.385079491824542297e-21 0.000000000000000000e+00 2.415657820710265911e-20 5.458807597464735062e-20 3.470000000000000284e+01 8.719026509990127086e-20 2.881436917098819324e-20 1.010395615205295344e-20 2.289677050749913027e-21 1.811939534294575476e-20 8.204855090669838777e-21 5.887784544747788324e-21 8.130871804678410839e-21 2.929590640910371892e-20 5.789342998656981932e-21 2.341241831318654724e-21 0.000000000000000000e+00 2.401342995493143647e-20 5.392497098417256426e-20 3.480000000000000426e+01 8.419331391784980538e-20 2.877298466367575085e-20 9.811369105673108137e-21 2.259294558723720936e-21 1.808630663517769714e-20 8.119154754738018107e-21 5.853452760741206039e-21 8.084571167927912747e-21 2.902344023661961549e-20 5.667054215570726220e-21 2.303963312213334497e-21 0.000000000000000000e+00 2.387028170276021684e-20 5.358623485630928025e-20 3.489999999999999858e+01 9.278189210288992459e-20 2.873178993134361275e-20 1.006083865132438025e-20 2.229227168803879060e-21 1.805385345778016047e-20 8.033496220474028838e-21 5.819120976734626763e-21 8.038278817082694204e-21 2.905790285612394043e-20 6.168857928859334996e-21 2.265836013589463520e-21 0.000000000000000000e+00 2.372777154625633918e-20 5.358374888166724248e-20 3.500000000000000000e+01 9.365917102407229846e-20 2.869078579143848594e-20 1.029585036616622841e-20 2.199663648787785339e-21 1.802156090751010611e-20 7.947880839434315535e-21 5.784789192728044478e-21 7.991994896127087927e-21 2.539966230954558092e-20 6.237693501690408168e-21 2.233034919591261277e-21 0.000000000000000000e+00 2.358743116469229560e-20 5.162064024812800012e-20 3.510000000000000142e+01 8.915028792359357729e-20 2.864997306229401028e-20 1.020307786148889396e-20 2.170576375660051570e-21 1.798930016768223781e-20 7.862310021349634655e-21 5.750457408721462192e-21 7.945713142149793221e-21 2.761456564199815631e-20 6.306210296438507105e-21 2.208655188099656662e-21 0.000000000000000000e+00 2.344709078312825203e-20 5.261411275592603792e-20 3.520000000000000284e+01 8.653950933289056216e-20 2.860935256308238156e-20 1.011790449703925936e-20 2.141966137763367510e-21 1.795753428452839522e-20 7.776785237247706197e-21 5.716125624714880659e-21 7.900014436749845366e-21 2.721524188413506643e-20 5.522251088600406333e-21 2.178551800649001236e-21 0.000000000000000000e+00 2.330675040156420544e-20 5.217859868774168397e-20 3.530000000000000426e+01 8.637939787817816425e-20 2.856892511376543887e-20 9.681254988285993247e-21 2.113818193084498681e-21 1.792569094296499574e-20 7.691308022776363696e-21 5.681793840708298374e-21 7.857800470395744023e-21 2.764663868985824246e-20 5.142043453347548909e-21 2.152377723517234574e-21 0.000000000000000000e+00 2.316689407559737193e-20 5.216328004181362845e-20 3.539999999999999858e+01 8.892519585147076463e-20 2.853087967067834415e-20 8.897950243038740407e-21 2.085931439478684244e-21 1.789441779322616165e-20 7.613005197587474359e-21 5.649302097602262818e-21 7.815594018136778859e-21 2.670821622200229777e-20 5.586419921895389610e-21 2.122448581258168896e-21 0.000000000000000000e+00 2.302917604427233131e-20 5.145956200928070054e-20 3.550000000000000000e+01 9.874740681141143810e-20 2.849609241871980641e-20 8.208097810189244278e-21 2.058800731278775562e-21 1.786278072612495637e-20 7.544816247071048161e-21 5.619414176874516261e-21 7.773395202368611503e-21 2.860192084353660211e-20 6.375420661181865288e-21 2.096935598962465400e-21 0.000000000000000000e+00 2.289145801294728167e-20 5.233332917745444509e-20 3.560000000000000142e+01 1.437414340492204837e-19 2.846145391209721629e-20 8.416340869479984478e-21 2.031809739951731369e-21 1.783182557242051245e-20 7.476650996281078143e-21 5.589526256146770456e-21 7.731204148136783071e-21 3.034106373093646548e-20 5.472954476690898434e-21 2.074573165017454431e-21 0.000000000000000000e+00 2.275373998162223202e-20 5.312697952972465231e-20 3.570000000000000284e+01 2.811493604128047246e-19 2.842696469455308470e-20 8.681093771920575374e-21 2.005433581326922662e-21 1.780045027623631116e-20 7.408510099396816291e-21 5.559638335419023900e-21 7.689020983208175196e-21 2.984268309293639001e-20 5.130685636196334704e-21 2.055886083883564971e-21 0.000000000000000000e+00 2.261623949422278504e-20 5.274351879079279767e-20 3.580000000000000426e+01 5.889305202843288754e-18 2.839262531012272407e-20 9.240517025057850601e-21 1.979410366728535449e-21 1.777007577796398537e-20 7.340394234650385957e-21 5.529750414691278095e-21 7.646845838144770133e-21 2.556495945065715347e-20 2.214522913212353622e-20 2.030344975079131554e-21 0.000000000000000000e+00 2.248080982281923692e-20 5.484198391672853710e-20 3.589999999999999858e+01 1.175922062758651846e-17 2.835843630310732149e-20 1.011130011536297958e-20 1.953872221675129314e-21 1.773993280149551557e-20 7.272304105430612056e-21 5.499862493963533795e-21 7.604678846379809255e-21 2.727349862096351501e-20 3.155592376759972660e-20 1.996974379780373277e-21 0.000000000000000000e+00 2.234538015141569783e-20 6.007372253731690449e-20 3.600000000000000000e+01 5.872253122384622483e-18 2.832439821804674092e-20 1.094959315919169798e-20 1.928704079791501498e-21 1.770998520372700660e-20 7.204240441447481946e-21 5.469974573235787991e-21 7.562520144296425159e-21 3.109106380161275682e-20 1.941043434810691448e-20 1.981259798181392302e-21 0.000000000000000000e+00 2.220995048001214971e-20 5.673771685416560719e-20 3.610000000000000142e+01 8.477886289562399175e-20 2.829051159969192222e-20 1.109456205436619031e-20 1.903860539686918152e-21 1.767942362928015804e-20 7.136203999961189659e-21 5.440086652508041434e-21 7.520369871308861741e-21 2.837998570118534010e-20 6.431350458652009463e-21 2.014191268316856961e-21 0.000000000000000000e+00 2.207452080860860159e-20 5.210405228388965305e-20 3.620000000000000284e+01 8.803887210131715880e-20 2.825677699297705148e-20 1.119599684681578826e-20 1.879416148791458784e-21 1.764937684541156235e-20 7.068195567079832009e-21 5.410198731780295629e-21 7.478228169946343936e-21 2.845732691349137016e-20 6.544592084036567249e-21 2.018240249786674627e-21 0.000000000000000000e+00 2.194137465015662024e-20 5.207811815745847756e-20 3.630000000000000426e+01 8.558262860770888019e-20 2.822319494299132806e-20 1.081188385673267944e-20 1.855416148528545635e-21 1.761990632110935329e-20 7.000215959130268980e-21 5.380310811052549072e-21 7.438873826993600038e-21 2.724260685457211534e-20 6.174973269471429893e-21 1.991028579444852171e-21 0.000000000000000000e+00 2.180832825497355628e-20 5.119076229237742328e-20 3.639999999999999858e+01 8.481006520954179695e-20 2.818976599495046086e-20 9.996893926177434502e-21 1.831717902660815945e-21 1.759054218972826571e-20 6.932266024106946651e-21 5.350422890324805525e-21 7.400045776904052197e-21 2.844303430386680872e-20 5.305769277769601502e-21 1.994661427865366757e-21 0.000000000000000000e+00 2.167528185979050134e-20 5.147602432990009019e-20 3.650000000000000000e+01 9.743546544015377030e-20 2.815649069416783351e-20 9.355865698987593553e-21 1.808349481362210016e-21 1.756120838065149297e-20 6.864346643203787897e-21 5.320534969597058968e-21 7.361217477670761484e-21 2.910137976586592212e-20 5.501268951452637498e-21 1.995891529905746574e-21 0.000000000000000000e+00 2.154223546460743738e-20 5.164113655742968927e-20 3.660000000000000142e+01 6.297384732435690151e-18 2.812336958602532052e-20 9.885881554747876530e-21 1.785456007440129742e-21 1.753218628668488185e-20 6.796458732434773661e-21 5.290647048869313164e-21 7.322393510044029058e-21 2.387644957474841007e-20 2.019817820180384730e-20 1.996535663783625372e-21 0.000000000000000000e+00 2.141198723512859760e-20 5.260732670766434936e-20 3.670000000000000284e+01 1.257037925555260883e-17 2.809040321594384464e-20 1.055377521833561165e-20 1.762871659385387119e-21 1.750334033130191961e-20 6.728603244349075353e-21 5.260759128141566607e-21 7.283588655000312157e-21 2.680320231095146402e-20 3.295590809201939554e-20 2.006307725450213844e-21 0.000000000000000000e+00 2.128255948411259368e-20 5.997836323649689508e-20 3.680000000000000426e+01 6.277113939698668523e-18 2.805759212935355502e-20 1.074523963487906441e-20 1.740701386299814090e-21 1.747459059921467909e-20 6.660781169847209044e-21 5.230871207413820802e-21 7.244791814737445331e-21 2.068884526661450352e-20 2.097234733976345998e-20 2.011863764768958012e-21 0.000000000000000000e+00 2.115313173309659276e-20 5.152344404235731654e-20 3.689999999999999858e+01 8.404458922078223299e-20 2.802493687166372855e-20 1.042427404588765965e-20 1.718776006776367158e-21 1.744609673512451846e-20 6.592993540105107943e-21 5.200983286686076502e-21 7.206003118709236764e-21 2.643751148450455078e-20 4.987122178541884864e-21 2.017899240240542298e-21 0.000000000000000000e+00 2.102370398208060088e-20 4.993704814863738877e-20 3.700000000000000000e+01 7.992062640882248328e-20 2.799243798823231608e-20 1.008358389917292777e-20 1.697119664687331414e-21 1.741753242555388576e-20 6.525241428613531743e-21 5.171095365958330698e-21 7.167222699144409112e-21 2.401235997183555069e-20 4.619552389056674212e-21 2.018463463502651393e-21 0.000000000000000000e+00 2.089786985945441981e-20 4.848631599782849364e-20 3.710000000000000142e+01 7.670450515004312739e-20 2.796305657825471923e-20 9.315355622702952107e-21 1.675975178781192635e-21 1.738926378759139423e-20 6.466812068310708097e-21 5.143888584191614323e-21 7.128450691120586806e-21 2.431354220147716555e-20 5.270669136580335967e-21 2.034751888508827972e-21 0.000000000000000000e+00 2.077509846142549191e-20 4.845277131041747786e-20 3.720000000000000284e+01 5.365030145000948567e-18 2.793511214798709010e-20 8.533245465054834470e-21 1.654940695830746500e-21 1.736121735958983088e-20 6.412515904093103668e-21 5.117869318625433507e-21 7.089687232640615546e-21 2.962635459377576833e-20 1.779968008587854679e-20 2.058471232554694844e-21 0.000000000000000000e+00 2.065232706339656401e-20 5.385368596544802916e-20 3.730000000000000426e+01 1.071609829023881719e-17 2.790728804552601576e-20 8.187368808209321731e-21 1.634383937611603911e-21 1.733312455797955369e-20 6.358237309430448470e-21 5.091850053059251939e-21 7.051750899643078001e-21 1.943895146083338280e-20 2.640598190886104657e-20 2.074801333189203181e-21 0.000000000000000000e+00 2.052955566536763612e-20 5.259235336158109358e-20 3.739999999999999858e+01 5.370420232403460720e-18 2.787958463113652936e-20 8.308042280011338267e-21 1.614058467345711553e-21 1.730581018806910314e-20 6.303976738155692091e-21 5.065830787493071875e-21 7.016405285489687659e-21 3.298472127998107706e-20 1.246734523461487345e-20 2.097376608446720465e-21 0.000000000000000000e+00 2.040751512905103496e-20 5.410467596837478663e-20 3.750000000000000000e+01 8.867554238528869326e-20 2.785200226495127447e-20 8.438101448921996437e-21 1.594090175124058622e-21 1.727862057883798366e-20 6.249734659709254818e-21 5.039811521926890307e-21 6.981067132187789649e-21 2.562431416077995941e-20 5.242284218992430946e-21 2.117284667028989378e-21 0.000000000000000000e+00 2.028758284747175988e-20 4.859400737557835162e-20 3.760000000000000142e+01 8.246193203316493243e-20 2.782454130695417672e-20 8.093326972233591270e-21 1.574433903767740453e-21 1.725102606935022296e-20 6.195511559808647151e-21 5.013792256360708739e-21 6.945736553614171458e-21 2.555917501460363527e-20 5.054529893344754793e-21 2.135055165034727779e-21 0.000000000000000000e+00 2.016765056589248781e-20 4.839072023962894310e-20 3.770000000000000284e+01 7.708921262559507662e-20 2.779720211696402530e-20 7.714530244405385668e-21 1.555018310383605745e-21 1.722379056886452154e-20 6.141307941152467163e-21 4.987772990794527924e-21 6.910413665949807674e-21 2.667505976561374949e-20 4.750706384250654570e-21 2.151386710838306879e-21 0.000000000000000000e+00 2.004771828431321273e-20 4.880871155269743440e-20 3.780000000000000426e+01 7.064408691820283160e-20 2.776998505461789190e-20 7.554420827621605413e-21 1.535841013543486955e-21 1.719723145834440845e-20 6.087124324160836304e-21 4.961753725228346356e-21 6.875098587737783833e-21 2.419213388927689122e-20 4.348436872294316880e-21 2.170767004780406029e-21 0.000000000000000000e+00 1.992778600273394065e-20 4.734217057014611768e-20 3.789999999999999858e+01 7.164873585163180524e-20 2.774289047935442324e-20 7.610818946354323062e-21 1.517051097422475490e-21 1.716999695053805187e-20 6.032961247754462887e-21 4.935734459662166292e-21 6.839791439942940061e-21 2.461840890770815889e-20 4.620814026393647935e-21 2.192774506483355765e-21 0.000000000000000000e+00 1.981033257290200205e-20 4.750704301060363378e-20 3.800000000000000000e+01 7.522782260396417844e-20 2.771591875039701932e-20 7.686358562604194294e-21 1.498505887191172342e-21 1.714296897490255729e-20 5.978819270174668458e-21 4.909715194095985477e-21 6.804474749994774043e-21 2.445856962440295615e-20 4.465599793746094582e-21 2.208839481606458966e-21 0.000000000000000000e+00 1.969307916480143467e-20 4.733277060887227931e-20 3.810000000000000142e+01 7.477557936066558759e-20 2.768907022673686110e-20 8.038044080691476569e-21 1.480288004694409253e-21 1.711680346441432665e-20 5.924698969846923617e-21 4.883695928529803909e-21 6.769180644378248041e-21 2.388898372151207475e-20 5.117643693888941327e-21 2.259313277761094060e-21 0.000000000000000000e+00 1.957582575670086729e-20 4.707904626530207055e-20 3.820000000000000284e+01 7.191616319849938008e-20 2.766234526711580591e-20 8.423117695312152391e-21 1.462326671221286108e-21 1.709025164461288239e-20 5.870600946290489566e-21 4.857676662963622341e-21 6.733897929856890073e-21 2.289757390017052928e-20 4.218738001475030308e-21 2.307747670593625078e-21 0.000000000000000000e+00 1.945857234860030291e-20 4.647401526997302200e-20 3.830000000000000426e+01 7.760238302826347694e-20 2.763574423000914429e-20 8.390621367955296567e-21 1.444578671086633841e-21 1.706403590049000387e-20 5.816525821077110671e-21 4.831657397397440773e-21 6.698623653965872850e-21 2.404564861341182686e-20 4.215992455410143992e-21 2.350809111725124789e-21 0.000000000000000000e+00 1.934263193082611924e-20 4.695833240908931919e-20 3.840000000000000568e+01 7.411578679062463661e-20 2.760926747360830880e-20 7.955304317167299330e-21 1.427061161314895826e-21 1.703802479527142964e-20 5.762474238841774095e-21 4.805638131831259205e-21 6.664267667177539040e-21 2.468356454318259404e-20 4.523542106823727406e-21 2.395871304761765557e-21 0.000000000000000000e+00 1.922779642921081976e-20 4.715709052750645018e-20 3.850000000000000000e+01 8.144839593544573007e-20 2.758291535580328183e-20 7.575084817391085484e-21 1.409904136395286434e-21 1.701187064301594152e-20 5.708446868348851954e-21 4.779618866265079894e-21 6.631781779352699546e-21 2.296426905988796354e-20 4.599479572775113329e-21 2.441243371635715006e-21 0.000000000000000000e+00 1.911296092759552931e-20 4.613870570468719442e-20 3.860000000000000142e+01 8.072771919282463489e-20 2.755668823416511176e-20 7.463514143435696508e-21 1.392957689992156236e-21 1.698649300974941023e-20 5.654444403617112228e-21 4.753599600698898326e-21 6.599303391578728387e-21 2.284048202729130386e-20 4.020121283504419416e-21 2.487598997374253362e-21 0.000000000000000000e+00 1.899812542598023283e-20 4.591995812801001380e-20 3.870000000000000284e+01 7.562396946597039584e-20 2.753058646592804396e-20 7.372620261584463041e-21 1.376217194006460517e-21 1.696121946711959344e-20 5.600467565107424714e-21 4.727580335132716758e-21 6.566832615137386454e-21 2.410171282639986456e-20 3.468272901105161834e-21 2.533610601488880260e-21 0.000000000000000000e+00 1.888356447567474420e-20 4.641803390595360159e-20 3.880000000000000426e+01 7.659964320120184363e-20 2.750523677156027930e-20 7.475497114265314324e-21 1.359735413645452405e-21 1.693523214766722354e-20 5.548427102414497746e-21 4.702171621025659227e-21 6.534369563496031853e-21 2.195051644579064348e-20 3.630216165185968499e-21 2.579431311966963516e-21 0.000000000000000000e+00 1.877122657373528031e-20 4.528445182102547800e-20 3.890000000000000568e+01 7.318459128879305664e-20 2.748282423508435889e-20 7.782213164687150123e-21 1.343502298780267730e-21 1.690987931973740541e-20 5.505030873515090905e-21 4.679520256724663155e-21 6.501914352360856063e-21 2.281669551739397237e-20 4.285663651207072700e-21 2.622437194055889126e-21 0.000000000000000000e+00 1.865888867179581642e-20 4.573943006069216239e-20 3.900000000000000000e+01 7.568352658035491245e-20 2.746050811922318812e-20 8.071849891433656494e-21 1.327454637737448333e-21 1.688488131249530345e-20 5.461647337186313408e-21 4.656868892423668588e-21 6.469467099731666112e-21 2.302426448277583662e-20 3.902651896882330995e-21 2.668765809655068132e-21 0.000000000000000000e+00 1.854655076985636156e-20 4.578110906112135625e-20 3.910000000000000142e+01 6.822554136692847012e-20 2.743828865923929303e-20 7.872473775708481354e-21 1.311747320560121597e-21 1.686007267649278884e-20 5.418276798312143988e-21 4.634217528122672517e-21 6.437027925958251133e-21 2.216137981869925424e-20 4.690160876999383602e-21 2.695436481308981249e-21 0.000000000000000000e+00 1.843421286791689767e-20 4.531332287608641708e-20 3.920000000000000284e+01 7.102797236751750558e-20 2.741616609013721537e-20 7.655199059783003402e-21 1.296226670052717413e-21 1.683509390687429779e-20 5.374919571524251799e-21 4.611566163821676445e-21 6.404596953798410025e-21 2.429152428685372746e-20 3.318088994261992113e-21 2.721447494069786850e-21 0.000000000000000000e+00 1.832335344946895813e-20 4.616019298090487466e-20 3.930000000000000426e+01 7.272084495417803362e-20 2.739414064665425000e-20 7.343325390249162892e-21 1.280900491093624328e-21 1.680978096934251230e-20 5.331575981590675409e-21 4.588914799520679622e-21 6.372172624265905235e-21 2.167445471944568581e-20 4.464597359851717287e-21 2.752239371308017126e-21 0.000000000000000000e+00 1.821337945767222979e-20 4.480711848686897200e-20 3.940000000000000568e+01 7.823484574782998289e-20 2.737221256325095371e-20 6.934173078246325594e-21 1.265794841904027749e-21 1.678529521943680350e-20 5.288246363823085512e-21 4.566263435219683550e-21 6.339739616371766038e-21 2.510841333328156080e-20 3.782213315528860595e-21 2.778423212651622658e-21 0.000000000000000000e+00 1.810340546587550144e-20 4.636667166758448496e-20 3.950000000000000000e+01 8.249382944855894030e-20 2.735038207410173225e-20 6.570879615322732720e-21 1.250914841812443609e-21 1.676085869973472532e-20 5.244931064503611628e-21 4.543612070918688983e-21 6.307602819554403402e-21 2.315049556547434631e-20 3.815838243169767121e-21 2.805239140813896469e-21 0.000000000000000000e+00 1.799343147407877911e-20 4.520829134062247202e-20 3.960000000000000142e+01 7.777555444926906222e-20 2.732864941308538517e-20 6.706619776146085972e-21 1.236205164304768080e-21 1.673658552317271377e-20 5.201630441332339454e-21 4.520960706617692912e-21 6.278015819811247455e-21 2.422572628155337558e-20 4.003228134191487364e-21 2.835298387199733400e-21 0.000000000000000000e+00 1.788364884527815272e-20 4.572920637480421714e-20 3.970000000000000284e+01 7.311113746407847791e-20 2.730701481377546418e-20 6.895359023703948737e-21 1.221722583573866161e-21 1.671243893878846676e-20 5.158344863896647195e-21 4.498309342316696840e-21 6.248436192404480054e-21 2.323481004831159066e-20 3.654546270740829999e-21 2.862142949456202259e-21 0.000000000000000000e+00 1.777582564345749301e-20 4.513632090655947498e-20 3.980000000000000426e+01 7.516795888381102291e-20 2.728547850943075181e-20 7.113619960670880077e-21 1.207467842845211497e-21 1.668832823628887704e-20 5.115074714163610936e-21 4.475657978015700016e-21 6.218864042532235338e-21 2.498147610475967359e-20 3.736155911315409755e-21 2.888760056157971890e-21 0.000000000000000000e+00 1.766800244163683631e-20 4.602678820317914487e-20 3.990000000000000568e+01 7.657775398977992890e-20 2.726404073298556556e-20 7.359677911594684693e-21 1.193398722764122305e-21 1.666429934954168260e-20 5.071820386996799352e-21 4.453006613714703945e-21 6.189299477376324442e-21 2.439356020873031597e-20 3.371764173803714750e-21 2.916254567478665314e-21 0.000000000000000000e+00 1.756017923981617659e-20 4.564816443486904981e-20 4.000000000000000000e+01 7.289459786055319809e-20 2.724270171704008612e-20 7.621716907044606310e-21 1.179493336019427923e-21 1.664048307561137749e-20 5.028582290698860839e-21 4.430355249413709378e-21 6.159742606148539819e-21 2.289391855475739355e-20 3.581125864046823259e-21 2.941852885353695078e-21 0.000000000000000000e+00 1.745235603799552591e-20 4.485091484418732320e-20 4.010000000000000142e+01 7.164589730482204445e-20 2.722146169385059531e-20 7.967728262994198836e-21 1.165874288324623734e-21 1.661672289522418195e-20 4.985360847581385117e-21 4.407703885112713307e-21 6.130193540138241511e-21 2.467807081282526442e-20 3.859887659953633393e-21 2.918137279982743464e-21 0.000000000000000000e+00 1.734565370382423301e-20 4.579433918731244920e-20 4.020000000000000284e+01 7.566112981552838439e-20 2.720032089531971404e-20 8.328529144939318914e-21 1.152394923171578013e-21 1.659299002639411213e-20 4.942156494563677860e-21 4.385052520811717235e-21 6.100652392761279529e-21 2.601403188649828087e-20 4.465348100349274842e-21 2.894296399332510158e-21 0.000000000000000000e+00 1.724007257714422226e-20 4.657268497099138536e-20 4.030000000000000426e+01 7.591433402645040307e-20 2.717927955298650783e-20 8.528101986884908623e-21 1.139137010339294185e-21 1.656943575261242288e-20 4.898969683802083129e-21 4.362401156510720411e-21 6.071119279610268148e-21 2.667551695924524921e-20 3.815155346273020688e-21 2.872128707547512636e-21 0.000000000000000000e+00 1.713449145046421151e-20 4.685246063831329400e-20 4.040000000000000568e+01 7.587963636192653992e-20 2.715833789801668261e-20 8.561794909717563746e-21 1.126080317356708196e-21 1.654629045506692175e-20 4.855800883351705071e-21 4.339749792209724340e-21 6.041594318506279069e-21 2.561348117825760664e-20 3.518029173470901853e-21 2.846025036207305259e-21 0.000000000000000000e+00 1.702891032378420076e-20 4.616655845097396062e-20 4.050000000000000000e+01 7.859479552037747856e-20 2.713749616119257593e-20 8.556981680209459668e-21 1.113179529887904007e-21 1.652359266705883804e-20 4.812650577862466830e-21 4.317098427908729773e-21 6.012077629551993328e-21 3.004208617222157265e-20 3.713637164461308418e-21 2.822661120468663454e-21 0.000000000000000000e+00 1.692332919710419603e-20 4.870895675329595108e-20 4.060000000000000142e+01 7.593438794634228690e-20 2.711675457290323841e-20 7.987251402524980369e-21 1.100423624311424114e-21 1.650040134678793992e-20 4.769519269311533436e-21 4.294447063607733701e-21 5.982569335186339773e-21 3.379337448164143727e-20 3.339807173411576648e-21 2.798918110204258637e-21 0.000000000000000000e+00 1.681958106131531171e-20 5.092591860990645938e-20 4.070000000000000284e+01 9.041141463969086925e-20 2.709844677323209627e-20 7.378264446461915754e-21 1.087820789603114096e-21 1.647724484627398551e-20 4.733372874791342698e-21 4.274262657500361625e-21 5.954307607273007703e-21 5.134684071412789173e-20 3.714850353388450860e-21 2.776559955864210126e-21 0.000000000000000000e+00 1.671613707752998286e-20 6.383582194293803005e-20 4.080000000000000426e+01 4.069326056552218513e-19 2.708065754802130694e-20 7.029445462030807348e-21 1.075442792838093875e-21 1.645414314634743596e-20 4.698549400978103832e-21 4.254543257527621862e-21 5.927154496316811590e-21 2.887553511282539829e-19 1.318250335933076091e-20 2.751968274719422697e-21 0.000000000000000000e+00 1.661269309374465402e-20 2.914909351713649352e-19 4.090000000000000568e+01 1.470168633959218091e-18 2.706294533641817906e-20 6.940055501336295793e-21 1.063256564581119920e-21 1.643155645298087370e-20 4.663735269914068549e-21 4.234823857554882852e-21 5.900014617582203327e-21 3.843854749447154256e-18 1.796571662034816883e-19 2.726786365231956388e-21 0.000000000000000000e+00 1.650924910995932818e-20 3.848233648202855955e-18 4.100000000000000000e+01 1.338086293461447054e-18 2.704531028973338668e-20 6.861804352251919617e-21 1.051162814523622316e-21 1.640927840933379146e-20 4.628930692399350816e-21 4.215104457582145345e-21 5.872882263679947165e-21 7.692918538970068768e-18 9.409649772314297169e-20 2.702574866188080917e-21 0.000000000000000000e+00 1.640616043990879703e-20 7.693584915467187686e-18 4.110000000000000142e+01 4.063960443391839803e-19 2.702775255901244241e-20 6.954498914684087295e-21 1.039310389563928255e-21 1.638634737045445078e-20 4.594135885563303097e-21 4.195385057609406335e-21 5.845757539386751419e-21 6.339729913608451138e-19 1.199424857354521480e-20 2.710322086973027658e-21 0.000000000000000000e+00 1.630491473321468047e-20 6.351851297814183920e-19 4.120000000000000284e+01 8.033937980996874322e-20 2.701027229503051848e-20 7.158621234902313778e-21 1.027570854626689213e-21 1.636453296595924187e-20 4.559351073101499771e-21 4.175665657636667324e-21 5.818640551403336696e-21 3.770944572368157014e-20 3.542530920162026267e-21 2.719577945343123098e-21 0.000000000000000000e+00 1.620366902652056691e-20 5.316240935548101893e-20 4.130000000000000426e+01 7.353958329947702146e-20 2.699286964828727081e-20 7.369173279880448894e-21 1.016000001861370458e-21 1.634214606785022020e-20 4.524576485523323708e-21 4.155946257663928313e-21 5.791531408398070994e-21 2.832746312929217877e-20 2.976554752791093922e-21 2.727387944753414489e-21 0.000000000000000000e+00 1.610242331982645336e-20 4.690772820995830709e-20 4.140000000000000568e+01 7.488137655951074590e-20 2.697554476900156676e-20 7.518401113143810688e-21 1.004626463348898804e-21 1.631964299413152608e-20 4.489812360410722475e-21 4.136226857691189302e-21 5.764430221051780678e-21 2.296542234427034579e-20 3.118176099076782223e-21 2.733510065252660482e-21 0.000000000000000000e+00 1.600117761313233980e-20 4.384843490949324118e-20 4.150000000000000000e+01 7.833637782094520333e-20 2.695829780710630620e-20 7.653252795325864621e-21 9.933649248377605099e-22 1.629738820295047526e-20 4.455058942688720246e-21 4.116507457718451796e-21 5.737337102103778698e-21 2.169427079661010788e-20 3.954021157708487047e-21 2.743491139763147824e-21 0.000000000000000000e+00 1.590107582787254581e-20 4.322349570317964913e-20 4.160000000000000142e+01 7.293868092625974492e-20 2.694112891224311619e-20 7.493434480710248909e-21 9.822492324817613296e-22 1.627571642708885907e-20 4.420316484908300045e-21 4.096788057745712033e-21 5.710252166399115327e-21 2.365357399423462062e-20 3.464954231725759300e-21 2.749688941181474292e-21 0.000000000000000000e+00 1.580261236744659047e-20 4.410839391330117561e-20 4.170000000000000284e+01 7.313067369276004860e-20 2.692403823375714189e-20 7.320355928830602485e-21 9.712885512845013838e-22 1.625348698262041049e-20 4.385585247542328904e-21 4.077068657772973022e-21 5.683175530937148459e-21 2.275218059988327308e-20 3.445791039287781415e-21 2.758858095064775919e-21 0.000000000000000000e+00 1.570414890702063212e-20 4.353770556677820484e-20 4.180000000000000426e+01 7.084252530426540814e-20 2.690702592069171419e-20 7.277327659647499380e-21 9.604909107119483956e-22 1.623193175121457408e-20 4.350865499295198495e-21 4.057349257800234012e-21 5.656107314921404879e-21 2.276198458958146830e-20 3.302328532193667737e-21 2.765459714637261138e-21 0.000000000000000000e+00 1.560568544659467677e-20 4.346179768901827946e-20 4.190000000000000568e+01 6.885276116087949146e-20 2.689009212178307144e-20 7.373726451406641541e-21 9.498848500620670826e-22 1.621065592043479558e-20 4.316157517426944844e-21 4.037629857827495001e-21 5.630539390417556064e-21 2.137233511732036830e-20 2.695172789872864209e-21 2.770794276551263571e-21 0.000000000000000000e+00 1.550722198616871842e-20 4.266102538024565456e-20 4.200000000000000000e+01 6.602540599678439576e-20 2.687323698545505110e-20 7.478309817782534682e-21 9.393667190920135576e-22 1.618922926194991024e-20 4.281461588092612239e-21 4.017910457854757495e-21 5.605825044228730634e-21 2.235045738952187448e-20 3.214399516678223661e-21 2.781628774141077222e-21 0.000000000000000000e+00 1.541021853588340867e-20 4.315155772014153028e-20 4.210000000000000142e+01 6.988843268219555356e-20 2.685646065981374229e-20 7.518986310585703769e-21 9.290159413428976054e-22 1.616733861759599435e-20 4.246778006697712934e-21 3.998191057882018484e-21 5.581105158477155736e-21 2.102044547283839496e-20 2.721712202514272498e-21 2.804429196134279439e-21 0.000000000000000000e+00 1.531416590678629222e-20 4.238956568067490111e-20 4.220000000000000284e+01 6.816833985544432655e-20 2.683976329264217142e-20 7.566553616482135530e-21 9.188066681197478180e-22 1.614622855738419271e-20 4.212107078270659877e-21 3.978471657909279473e-21 5.556411609488301013e-21 1.980866545249609196e-20 3.115142856294584682e-21 2.831496322493030319e-21 0.000000000000000000e+00 1.521811327768917576e-20 4.177690758640949788e-20 4.230000000000000426e+01 6.259147807560530001e-20 2.682314503139492161e-20 7.612815004782929407e-21 9.086551529295364769e-22 1.612527873542614694e-20 4.177449117853106817e-21 3.958752257936540462e-21 5.531725574948345706e-21 2.147360997281356438e-20 3.040568669949853778e-21 2.855809917071103341e-21 0.000000000000000000e+00 1.512206064859205931e-20 4.253472076088275174e-20 4.240000000000000568e+01 6.406779470210915246e-20 2.680660602319276719e-20 7.660692304287105398e-21 8.987076705495145957e-22 1.610398828214149370e-20 4.142804450909205405e-21 3.939032857963801451e-21 5.507047155910689554e-21 2.102471861727999540e-20 2.852615354260658969e-21 2.879494921800304266e-21 0.000000000000000000e+00 1.502600801949494285e-20 4.224549016623990996e-20 4.250000000000000000e+01 6.807180099549961924e-20 2.679014641481730818e-20 7.691224861535265456e-21 8.889101505933958028e-22 1.608255536108455120e-20 4.108173413754836302e-21 3.919313457991063193e-21 5.482376455216810039e-21 1.984285897399868186e-20 2.594200378749467239e-21 2.905980561761658301e-21 0.000000000000000000e+00 1.493163334490426827e-20 4.159888840595995136e-20 4.260000000000000142e+01 6.543963479950572056e-20 2.677518010958257927e-20 7.302389646015444067e-21 8.792264674691369932e-22 1.606173719889033749e-20 4.077714690252846363e-21 3.901212892891969279e-21 5.457713577535229374e-21 2.061682897522756710e-20 2.984631718731751274e-21 2.931310786034514068e-21 0.000000000000000000e+00 1.483783494955284314e-20 4.187286776064012814e-20 4.270000000000000284e+01 6.367405379815731046e-20 2.676109356856036491e-20 6.893203029913833200e-21 8.696024072844083587e-22 1.604108618824022047e-20 4.049662137571740586e-21 3.884045947443666114e-21 5.433058629401521176e-21 1.913637885675290226e-20 3.340997569250539654e-21 2.958768214209802183e-21 0.000000000000000000e+00 1.474403655420141499e-20 4.106401000422358900e-20 4.280000000000000426e+01 6.126814374977036010e-20 2.674706812899995660e-20 6.532265263626040549e-21 8.602133345689964946e-22 1.602047888331076854e-20 4.021616285017401806e-21 3.866879001995362197e-21 5.408411719259311714e-21 1.932923899636297496e-20 2.970256273992596510e-21 2.980717716261185014e-21 0.000000000000000000e+00 1.465023815884998685e-20 4.100981565936499009e-20 4.290000000000000568e+01 6.076897988892428579e-20 2.673310388707142632e-20 6.209401553033423103e-21 8.508940310537221035e-22 1.599996299574919431e-20 3.993577273749563790e-21 3.849712056547058280e-21 5.383772957502365235e-21 1.798641598648674308e-20 2.868878968812632373e-21 3.008028683973749394e-21 0.000000000000000000e+00 1.455643976349855871e-20 4.027868050156896698e-20 4.300000000000000000e+01 6.025071750162475285e-20 2.671920093872583467e-20 5.918323270437050285e-21 8.416497789491054197e-22 1.597955996451030340e-20 3.965545248885409301e-21 3.832545111098755867e-21 5.359142456517764675e-21 1.969898808844030671e-20 2.792801571349388573e-21 3.030174519413950443e-21 0.000000000000000000e+00 1.446457092433883676e-20 4.096812127904799306e-20 4.310000000000000142e+01 6.213700883552898949e-20 2.670535937969245339e-20 6.076382331593059066e-21 8.325534826220244718e-22 1.595919215222872639e-20 3.937520359637912057e-21 3.815378165650451950e-21 5.335281309048651969e-21 1.842788254409491465e-20 2.269311966740392055e-21 3.047779477148657263e-21 0.000000000000000000e+00 1.437310639994840061e-20 4.030664689917152780e-20 4.320000000000000284e+01 6.345095839970289491e-20 2.669157930547598475e-20 6.273737431123388210e-21 8.236411775811239524e-22 1.593885668224439886e-20 3.909502759459991082e-21 3.798211220202148033e-21 5.312623476808934878e-21 1.955843693598980241e-20 2.546777710026768772e-21 3.062652348010120385e-21 0.000000000000000000e+00 1.428164187555796145e-20 4.082675567513789493e-20 4.330000000000000426e+01 6.550743592064321949e-20 2.667786081135378404e-20 6.580903903488471944e-21 8.148323540225767676e-22 1.591863703746627238e-20 3.881492606194721954e-21 3.781044274753844116e-21 5.289972929349768382e-21 2.174778075263077625e-20 2.745696677454568353e-21 3.077971331961122249e-21 0.000000000000000000e+00 1.419017735116752530e-20 4.192576133468016256e-20 4.340000000000000568e+01 6.149812053396937750e-20 2.666420399237306693e-20 6.992525190598035807e-21 8.061094128178108764e-22 1.589851368592123600e-20 3.853490062231910399e-21 3.763877329305540199e-21 5.267324624522125186e-21 2.027043020444926875e-20 3.248874951488010890e-21 3.094720006889147820e-21 0.000000000000000000e+00 1.409871282677708613e-20 4.122917806871234585e-20 4.350000000000000000e+01 6.675353721654867273e-20 2.665060894334814399e-20 7.386152796036368035e-21 7.974623539667546953e-22 1.587838719370636627e-20 3.825495294671358484e-21 3.746710383857237786e-21 5.244668275460735856e-21 1.999097868772366588e-20 2.514640306047506853e-21 3.109927477585523663e-21 0.000000000000000000e+00 1.400916312212714230e-20 4.105653516295093820e-20 4.360000000000000142e+01 6.295400722704031257e-20 2.663707575885757690e-20 7.417567759773348234e-21 7.889783951596757178e-22 1.585844701982652210e-20 3.797508475493121344e-21 3.729543438408933869e-21 5.222039004786848998e-21 1.885847129022434601e-20 2.571103854893692465e-21 3.129232268993319255e-21 0.000000000000000000e+00 1.391994559832797815e-20 4.047316019266523358e-20 4.370000000000000284e+01 6.243659070424732132e-20 2.662360453324143704e-20 7.439968894770410189e-21 7.805883221411139183e-22 1.583854514049827134e-20 3.769529781735153149e-21 3.712376492960629952e-21 5.199418435117964048e-21 1.823400445961583323e-20 2.666796227117418116e-21 3.142366180736283249e-21 0.000000000000000000e+00 1.383072807452881400e-20 4.014246575503081054e-20 4.380000000000000426e+01 6.167472053206017896e-20 2.661019536059845872e-20 7.312991411664190057e-21 7.722742038465484201e-22 1.581866475569447433e-20 3.741559395678657551e-21 3.695209547512326034e-21 5.176805635392177462e-21 1.820901074702046313e-20 2.807471432345109546e-21 3.155341493460791786e-21 0.000000000000000000e+00 1.374151055072964985e-20 4.006366583199824403e-20 4.390000000000000568e+01 6.316311224868907957e-20 2.659684833478326762e-20 7.060790290667526624e-21 7.641292762855961758e-22 1.579880943309572088e-20 3.713597505041574431e-21 3.678042602064022117e-21 5.154200707875685429e-21 1.970157266149191125e-20 2.664971440086346975e-21 3.170704449706687639e-21 0.000000000000000000e+00 1.365229302693048569e-20 4.065723148947306790e-20 4.400000000000000000e+01 6.315743806325871761e-20 2.658356354940355812e-20 6.849405765501072444e-21 7.560800008995777516e-22 1.577913005530543491e-20 3.685644303180596407e-21 3.660875656615719705e-21 5.131603756600718267e-21 2.288863906809903435e-20 2.579038252339829360e-21 3.185357070436825380e-21 0.000000000000000000e+00 1.356481651891557415e-20 4.220384032014097313e-20 4.410000000000000142e+01 6.075984259708190927e-20 2.657034109781726161e-20 6.623046842981421262e-21 7.481043487025529222e-22 1.575947652092323314e-20 3.657699989302147688e-21 3.643708711167415787e-21 5.109014887402983203e-21 2.118844532558934928e-20 2.723925514437512375e-21 3.148140110410627755e-21 0.000000000000000000e+00 1.347772241623834574e-20 4.122445541883710822e-20 4.420000000000000284e+01 6.200707294045221205e-20 2.655718107312978692e-20 6.441553169160680122e-21 7.401913052018484576e-22 1.574015583642965467e-20 3.629764768682824814e-21 3.626541765719112622e-21 5.086434207960070126e-21 2.047860116884528067e-20 2.107612694765844397e-21 3.106958647525747711e-21 0.000000000000000000e+00 1.339062831356111582e-20 4.074375938576416797e-20 4.430000000000000426e+01 6.083921214756322123e-20 2.654408356819113449e-20 6.226655946414198049e-21 7.324330943573560068e-22 1.572139266327826729e-20 3.601838852899726591e-21 3.609374820270808705e-21 5.063861827830791717e-21 2.157142961556694455e-20 2.070820520156878432e-21 3.070009825621003459e-21 0.000000000000000000e+00 1.330353421088388740e-20 4.121559953104253249e-20 4.440000000000000568e+01 6.515560593553740996e-20 2.653104867559313387e-20 5.938306800067805324e-21 7.247785722395286253e-22 1.570195683324756401e-20 3.573922460071251759e-21 3.592207874822504788e-21 5.042834350439722926e-21 2.102125181204173313e-20 1.993617267167740973e-21 3.031259247521585266e-21 0.000000000000000000e+00 1.321644010820665749e-20 4.082981999244670603e-20 4.450000000000000000e+01 6.773955134612708403e-20 2.651807648766659992e-20 5.678545291961865929e-21 7.172197150759794871e-22 1.568254633068902860e-20 3.546015815108878219e-21 3.575040929374202375e-21 5.022240283746960869e-21 2.236467108713896646e-20 2.514279367965529281e-21 2.992761069022597837e-21 0.000000000000000000e+00 1.313095547304075297e-20 4.147731534315133712e-20 4.460000000000000142e+01 6.252894649430785528e-20 2.650609427012093428e-20 5.786553971950095693e-21 7.097625721986763761e-22 1.566347685879629129e-20 3.520815331106419528e-21 3.559026677511351594e-21 5.001653403817093735e-21 2.440621267025272687e-20 2.364068435417794267e-21 2.955380981352050562e-21 0.000000000000000000e+00 1.304606816078557992e-20 4.256960261118749249e-20 4.470000000000000284e+01 7.007382758469711921e-20 2.649502398451794805e-20 5.928666610314559672e-21 7.023865721790846766e-22 1.564494848046273928e-20 3.498122146818598567e-21 3.544081800059074095e-21 4.981073799759237023e-21 2.636098669411473471e-20 1.921448595551979402e-21 2.915733866763805412e-21 0.000000000000000000e+00 1.296118084853040687e-20 4.367022911882325198e-20 4.480000000000000426e+01 7.185755250934639128e-20 2.648400201968088585e-20 6.013568669483292442e-21 6.950950361925341656e-22 1.562574656647157924e-20 3.475433747601472151e-21 3.529136922606795843e-21 4.960501562129496518e-21 3.306444289769390987e-20 2.526788706652110827e-21 2.878069339167791296e-21 0.000000000000000000e+00 1.287629353627523382e-20 4.801121504968042689e-20 4.490000000000000568e+01 7.683141573297095827e-20 2.647302843596437478e-20 6.058612806956863439e-21 6.879177312094254970e-22 1.560655416703143084e-20 3.452750227784707876e-21 3.514192045154517591e-21 4.939921695152398630e-21 4.219773017550825491e-20 2.919680839261926368e-21 2.839012711869142403e-21 0.000000000000000000e+00 1.279140622402006077e-20 5.469088295359234731e-20 4.500000000000000000e+01 8.195310321269595323e-20 2.646210329355797468e-20 6.112629784227325770e-21 6.808170219714879786e-22 1.558771109432839032e-20 3.430071684172678962e-21 3.499247167702240845e-21 4.919350961651044933e-21 5.387550775185914047e-20 3.074304083497782430e-21 2.803366354580244716e-21 0.000000000000000000e+00 1.270775875855314080e-20 6.411415768502900660e-20 4.510000000000000142e+01 7.785778430933189401e-20 2.645122665248479990e-20 5.836715311731383980e-21 6.737804262092774375e-22 1.556941724322724731e-20 3.407398216125425537e-21 3.484302290249962593e-21 4.898801261601011594e-21 4.698687777043804274e-20 2.324858681989075184e-21 2.798570289784650720e-21 0.000000000000000000e+00 1.262501009478409547e-20 5.835014031968642120e-20 4.520000000000000284e+01 6.796958698159776894e-20 2.644039857260002974e-20 5.561975992660280044e-21 6.668123950267628782e-22 1.555054790085356284e-20 3.384729925642805737e-21 3.469357412797684342e-21 4.878259304294792437e-21 3.172866349098331502e-20 2.477782957492473161e-21 2.800493392198727942e-21 0.000000000000000000e+00 1.254226143101505165e-20 4.687838802824997162e-20 4.530000000000000426e+01 6.472281859143762643e-20 2.642961911358946999e-20 5.397514348490534397e-21 6.599673245876584335e-22 1.553209724635110046e-20 3.362066917451951733e-21 3.454412535345406842e-21 4.857725187958064631e-21 2.810871268152173491e-20 2.405444627050419090e-21 2.798830156872930805e-21 0.000000000000000000e+00 1.245951276724600633e-20 4.444246037749303303e-20 4.540000000000000568e+01 6.385342153416142872e-20 2.641888833496812050e-20 5.343556275896935846e-21 6.532276929354958704e-22 1.551375189902710248e-20 3.339409299098190928e-21 3.439467657893128591e-21 4.837199012446579351e-21 2.530191966950999526e-20 2.047136728842642896e-21 2.799694164377123363e-21 0.000000000000000000e+00 1.237676410347696251e-20 4.265436707174616965e-20 4.550000000000000000e+01 6.174280803569101622e-20 2.640820629607873381e-20 5.347250874281668972e-21 6.465681125003011057e-22 1.549509886956741003e-20 3.316757181039604603e-21 3.424522780440851844e-21 4.816680879279275730e-21 2.157407776882903216e-20 2.282139598267520242e-21 2.790525918998935854e-21 0.000000000000000000e+00 1.229477248654736159e-20 4.052195328802784933e-20 4.560000000000000142e+01 5.635326137305217880e-20 2.639757305609034656e-20 5.881418143336636951e-21 6.399946859116072954e-22 1.547701778147450399e-20 3.294110676745360184e-21 3.409577902988573592e-21 4.796170891672171212e-21 1.761006764281487645e-20 2.046785208290113015e-21 2.788979285528227149e-21 0.000000000000000000e+00 1.221406739306626372e-20 3.857610551746571849e-20 4.570000000000000284e+01 5.607430471979583319e-20 2.638698867399685315e-20 6.447839260643824025e-21 6.334883921904566911e-22 1.545864344250279004e-20 3.271469902798047332e-21 3.394633025536295341e-21 4.776966023059541072e-21 1.703493682406041688e-20 2.554736731586975482e-21 2.790195122304663437e-21 0.000000000000000000e+00 1.213336229958516435e-20 3.839249460516508124e-20 4.580000000000000426e+01 5.386829394651353625e-20 2.637645320861556727e-20 6.703892725424222042e-21 6.270463894565137871e-22 1.544021760840681069e-20 3.248834979000140496e-21 3.379688148084017465e-21 4.758076962027117754e-21 1.775340963001644197e-20 2.126610093823806338e-21 2.788567894056968607e-21 0.000000000000000000e+00 1.205265720610406648e-20 3.868873435763112881e-20 4.590000000000000568e+01 5.686318099836080766e-20 2.636596671858574737e-20 6.669490326716190008e-21 6.206852783314577444e-22 1.542248699220041417e-20 3.226206028484839186e-21 3.364743270631739214e-21 4.739195079370891190e-21 1.660081910418246765e-20 2.382391903522293239e-21 2.789009288562456766e-21 0.000000000000000000e+00 1.197195211262296861e-20 3.813716987912541371e-20 4.600000000000000000e+01 1.049230559991876698e-19 2.635552926236718535e-20 6.625009582893804325e-21 6.144275005399694257e-22 1.540465992066067335e-20 3.203583177831456381e-21 3.349798393179462467e-21 4.720320461234118489e-21 2.798980827700789676e-20 3.478519956394706743e-21 2.786189213592173750e-21 0.000000000000000000e+00 1.189147623368242222e-20 4.432438142408082630e-20 4.610000000000000142e+01 1.568100700431308799e-19 2.634514089823874100e-20 6.185442083474617406e-21 6.082256556990575033e-22 1.538694980832559343e-20 3.180966557185590917e-21 3.334853515727184215e-21 4.701453195109979429e-21 3.925043812989170462e-20 6.171453754855787542e-21 2.786447376778745339e-21 0.000000000000000000e+00 1.181304529820509177e-20 5.233348666925543622e-20 4.620000000000000284e+01 8.062612257640720290e-20 2.633480168429690058e-20 5.710714442268115628e-21 6.020794487895874732e-22 1.536933807748963833e-20 3.158356300384316317e-21 3.319908638274906340e-21 4.682591846157101388e-21 2.402249107113325389e-20 4.532937013388083048e-21 2.786523657648631867e-21 0.000000000000000000e+00 1.173461436272776133e-20 4.181782215331357328e-20 4.630000000000000426e+01 5.226695336538521721e-20 2.632451167845434442e-20 5.680728064863545379e-21 5.960656556734873618e-22 1.535096921275634779e-20 3.135752545086609129e-21 3.304963760822628089e-21 4.663717691175063581e-21 1.548125996248622895e-20 1.911237357717201450e-21 2.788483065038051565e-21 0.000000000000000000e+00 1.165618342725043089e-20 3.729247399727653285e-20 4.640000000000000568e+01 5.043711765145846915e-20 2.631427093843848140e-20 6.096703527612451187e-21 5.901084936394666263e-22 1.533318935436966048e-20 3.113155432909298518e-21 3.290018883370350213e-21 4.644866122819440658e-21 1.482186221567621820e-20 1.812451697376891234e-21 2.794339642671625691e-21 0.000000000000000000e+00 1.157775249177310044e-20 3.704026974163189840e-20 4.650000000000000000e+01 5.341867301237385362e-20 2.630407952179003758e-20 6.478016728739981018e-21 5.842013703398402480e-22 1.531571793287907835e-20 3.090565109568786120e-21 3.275074005918073090e-21 4.626029044287186695e-21 1.526468571040182004e-20 2.173117961342016588e-21 2.795800190476567606e-21 0.000000000000000000e+00 1.149932155629577602e-20 3.725914144069657852e-20 4.660000000000000142e+01 4.869527785679163301e-20 2.629393748586157870e-20 6.396370343761596285e-21 5.783657538899085100e-22 1.529835951740085852e-20 3.067981725028825808e-21 3.260129128465795215e-21 4.607199775450774919e-21 1.648398322911592297e-20 1.791372489341205004e-21 2.795916553642229915e-21 0.000000000000000000e+00 1.142267258918408123e-20 3.769816405970108736e-20 4.670000000000000284e+01 5.375006802586540952e-20 2.628449136037330114e-20 6.281927216912634777e-21 5.726035620978362521e-22 1.528100459874902118e-20 3.047280011655774711e-21 3.246058643516603445e-21 4.588378412455849572e-21 1.466648904965459439e-20 2.183258720988563046e-21 2.797339035407048953e-21 0.000000000000000000e+00 1.134655575527193157e-20 3.689840177479013355e-20 4.680000000000000426e+01 5.065536000147034812e-20 2.627587019281382530e-20 6.090038588771659180e-21 5.668971433001184901e-22 1.526366307464648348e-20 3.028855305967845564e-21 3.233048212351886360e-21 4.569565052991389079e-21 1.521981787613484876e-20 1.697603750173138936e-21 2.801313401837210136e-21 0.000000000000000000e+00 1.127043892135978042e-20 3.702314225105521343e-20 4.690000000000000568e+01 5.418284164715875063e-20 2.626728716162000889e-20 5.818606045874494057e-21 5.612644902280923919e-22 1.524630036352852833e-20 3.010433999768780125e-21 3.220037781187169274e-21 4.550759796319913802e-21 1.393492811932775591e-20 1.399106132059410838e-21 2.801826313957607064e-21 0.000000000000000000e+00 1.119432208744763076e-20 3.641476090824646539e-20 4.700000000000000000e+01 4.942059722889759088e-20 2.625874230418802785e-20 5.573035562659420160e-21 5.557400004217828729e-22 1.522842889540366658e-20 2.992016155848708654e-21 3.207027350022453317e-21 4.532708239538417452e-21 1.560050895732332879e-20 1.688119972958824748e-21 2.803073757783267207e-21 0.000000000000000000e+00 1.111820525353548562e-20 3.701721403290948378e-20 4.710000000000000142e+01 5.044398926913126302e-20 2.625023565779633566e-20 5.618084583355171688e-21 5.502675679791924083e-22 1.521105344154825652e-20 2.973601838541440152e-21 3.194016918857736232e-21 4.515564665564188346e-21 1.289826935214491149e-20 1.460988244284518050e-21 2.774337907649920238e-21 0.000000000000000000e+00 1.104287680828054386e-20 3.591508014544451083e-20 4.720000000000000284e+01 5.028681237991474801e-20 2.624176725960491100e-20 5.690055777949932436e-21 5.448351355368097547e-22 1.519390131504421534e-20 2.955191113771818045e-21 3.181006487693019523e-21 4.498428081907387450e-21 1.512747663123201334e-20 1.635845431971535256e-21 2.746936441374970804e-21 0.000000000000000000e+00 1.096884833807330911e-20 3.675083960052893308e-20 4.730000000000000426e+01 5.090802648227314980e-20 2.623333714665451451e-20 5.693214546214275704e-21 5.394870274189671231e-22 1.517678240562260095e-20 2.936784049104791150e-21 3.167996056528302438e-21 4.481298568761395687e-21 1.670888519368876428e-20 1.408440325623392646e-21 2.722802175147652419e-21 0.000000000000000000e+00 1.089481986786607436e-20 3.737981643604244188e-20 4.740000000000000568e+01 5.357700618755368105e-20 2.622494535586597853e-20 5.626273706003319967e-21 5.341895305839159544e-22 1.515977245512996735e-20 2.918380713796313141e-21 3.154985625363585352e-21 4.464176207517092833e-21 1.555389864107803573e-20 1.604254880277082473e-21 2.692753732443068094e-21 0.000000000000000000e+00 1.082079139765884112e-20 3.683401104102905391e-20 4.750000000000000000e+01 5.222426707999853089e-20 2.621659192403946688e-20 5.550995427730245464e-21 5.289546312459233067e-22 1.514283289092728001e-20 2.899981178846126199e-21 3.141975194198869395e-21 4.447061080784619022e-21 1.528557233747912723e-20 1.665058065340130002e-21 2.667466853880209186e-21 0.000000000000000000e+00 1.074676292745161239e-20 3.667146175720666159e-20 4.760000000000000142e+01 5.218974425849464097e-20 2.620827688785372254e-20 5.302022981061081251e-21 5.238128003645083051e-22 1.512600217960075750e-20 2.881585517052509332e-21 3.128964763034152310e-21 4.429952828363056489e-21 1.440336463977104129e-20 1.426191091601501159e-21 2.639604456329307572e-21 0.000000000000000000e+00 1.067273445724437764e-20 3.622346878762210871e-20 4.770000000000000284e+01 5.424564788635322260e-20 2.620000028386536646e-20 5.086169827937035414e-21 5.187071144498297130e-22 1.510986255394281930e-20 2.863193803069105339e-21 3.115954331869435601e-21 4.412830133595232159e-21 1.314635909644800106e-20 1.500173304792685442e-21 2.611364174370340289e-21 0.000000000000000000e+00 1.060069614055213405e-20 3.567264387111863048e-20 4.780000000000000426e+01 5.288891745201693950e-20 2.619176214850815729e-20 5.147221955181654736e-21 5.136332889380327516e-22 1.509332040798051446e-20 2.844806113463868571e-21 3.102943900704718516e-21 4.395727956796774622e-21 1.261068515399703198e-20 1.953703389605269485e-21 2.584138718968064618e-21 0.000000000000000000e+00 1.052882507217044739e-20 3.546827191511750126e-20 4.790000000000000568e+01 4.815488513435711855e-20 2.618356251809224810e-20 5.473246520580916541e-21 5.086797354384604286e-22 1.507653089903485789e-20 2.826422526780278650e-21 3.089933469540001430e-21 4.378642494539547374e-21 1.416252699652067421e-20 1.762800149283417088e-21 2.551101279274212933e-21 0.000000000000000000e+00 1.045695400378876223e-20 3.604643416408502415e-20 4.800000000000000000e+01 5.229117381690840754e-20 2.617540142880349427e-20 5.820901346544395597e-21 5.037589336644441625e-22 1.505984695541170202e-20 2.808043123600876222e-21 3.076923038375285473e-21 4.361564698006792761e-21 1.324513447352858056e-20 1.615525346019548184e-21 2.524885315407371433e-21 0.000000000000000000e+00 1.038508293540708158e-20 3.570338368850488093e-20 4.810000000000000142e+01 5.215376839618518519e-20 2.616727891670267103e-20 6.122924713820396330e-21 4.988522669899882844e-22 1.504318672077714099e-20 2.789667986613252768e-21 3.063912607210568388e-21 4.344494657598216763e-21 1.317869781716566758e-20 1.612210455029321304e-21 2.512627043142467182e-21 0.000000000000000000e+00 1.031321186702539643e-20 3.568977987331509165e-20 4.820000000000000284e+01 4.904521094236893156e-20 2.615919501772479943e-20 6.444372614187593637e-21 4.940618424209069887e-22 1.502654481301447346e-20 2.771297200678600919e-21 3.050902176045851679e-21 4.327432465098515751e-21 1.390509244326832601e-20 1.800650240580688375e-21 2.497217476485491388e-21 0.000000000000000000e+00 1.024219056018087556e-20 3.599057977069083823e-20 4.830000000000000426e+01 4.805204658243549099e-20 2.615114976767838196e-20 6.346118089156361156e-21 4.893125830896256716e-22 1.500991233968856453e-20 2.752930852902918191e-21 3.037891744881134594e-21 4.310378213703129779e-21 1.487487270778330568e-20 1.689595877192585292e-21 2.486177277403501039e-21 0.000000000000000000e+00 1.017242177447375285e-20 3.631604787990102900e-20 4.840000000000000568e+01 4.756171719170627100e-20 2.614314320224471042e-20 5.813470222353142619e-21 4.845973512943259948e-22 1.499337581296534560e-20 2.734569032711016112e-21 3.024881313716417508e-21 4.294284797980714136e-21 1.310305454833441610e-20 1.760831308117630758e-21 2.470587563768911296e-21 0.000000000000000000e+00 1.010265298876662864e-20 3.550103023544269985e-20 4.850000000000000000e+01 5.504345296535668591e-20 2.613517535697712567e-20 5.309597535074417099e-21 4.799709806860374497e-22 1.497719479471080661e-20 2.716211831923437423e-21 3.011870882551701552e-21 4.278593365746383602e-21 1.321539857471361479e-20 1.661500166288737130e-21 2.456760404649388807e-21 0.000000000000000000e+00 1.003288420305951045e-20 3.542094389641321608e-20 4.860000000000000142e+01 4.809817224666182956e-20 2.612724626730027732e-20 5.284435404767945601e-21 4.753818423922846255e-22 1.496149924362074375e-20 2.697859344836422797e-21 2.998860451386984842e-21 4.262908901569585238e-21 1.384119607062309089e-20 1.731738427168524630e-21 2.440940171722581960e-21 0.000000000000000000e+00 9.963115417352386236e-21 3.562126034145528160e-20 4.870000000000000284e+01 4.878012530661665561e-20 2.611935596850944364e-20 5.294431847654208791e-21 4.708292108066827008e-22 1.494516501520984499e-20 2.679511668305082425e-21 2.985850020222267757e-21 4.247231482646667845e-21 1.477041258594707578e-20 1.699859882052672233e-21 2.430069716722573773e-21 0.000000000000000000e+00 9.893346631645263530e-21 3.595557840791231288e-20 4.880000000000000426e+01 4.870251185217204622e-20 2.611150449576976721e-20 5.388034312997247958e-21 4.663364708620544829e-22 1.492882090866769286e-20 2.661168901829887196e-21 2.972839589057550672e-21 4.231561187283052564e-21 1.288409675206925201e-20 1.538091584418774976e-21 2.407590601172861561e-21 0.000000000000000000e+00 9.825249319083743684e-21 3.519164873900593127e-20 4.890000000000000568e+01 4.902760139199637716e-20 2.610413639261871926e-20 5.561328733282778025e-21 4.618872729946608768e-22 1.491250233043073112e-20 2.644119836282806676e-21 2.960484310267139968e-21 4.215897867977631516e-21 1.358069960289019742e-20 1.455019010684078493e-21 2.391787270782002832e-21 0.000000000000000000e+00 9.757514009820631542e-21 3.543955727165943790e-20 4.900000000000000000e+01 5.174469979659450356e-20 2.609749913444150918e-20 5.724971868035149011e-21 4.575236366248599702e-22 1.489696057891662384e-20 2.629097819868834383e-21 2.949157933076537879e-21 4.200219280751694683e-21 1.170331089801310987e-20 1.817512376890358216e-21 2.379914436649516912e-21 0.000000000000000000e+00 9.689778700557523913e-21 3.477156449462914532e-20 4.910000000000000142e+01 4.822070282059336025e-20 2.609089195504693893e-20 5.703458303258637016e-21 4.531942859694620045e-22 1.488106856992448844e-20 2.614078204953156305e-21 2.937831555885935038e-21 4.184560234709943986e-21 1.222689292269677909e-20 1.938215664713377301e-21 2.353492399702708608e-21 0.000000000000000000e+00 9.622043391294411770e-21 3.491799974148437624e-20 4.920000000000000284e+01 4.998352315573585500e-20 2.608431487729196015e-20 5.670675828352929425e-21 4.488952260557010476e-22 1.486493221811453253e-20 2.599061033169554363e-21 2.926505178695331822e-21 4.168919113412649133e-21 1.437592115951581301e-20 1.224570677178739030e-21 2.323639471974413235e-21 0.000000000000000000e+00 9.554308082031299628e-21 3.565481716375012705e-20 4.930000000000000426e+01 4.648896688856133215e-20 2.607776792395239165e-20 5.624483211180876348e-21 4.446887744370841343e-22 1.484953602719193668e-20 2.584046347112776545e-21 2.915178801504728981e-21 4.153285523639137820e-21 1.161520926465442964e-20 1.511273357696800016e-21 2.290699356468696866e-21 0.000000000000000000e+00 9.486939739767139356e-21 3.460148791335561279e-20 4.940000000000000568e+01 4.741143977339726159e-20 2.607125111772254629e-20 5.564889793523876745e-21 4.405117421734184634e-22 1.483374904651548429e-20 2.569034190366215004e-21 2.903852424314125764e-21 4.137659550759958484e-21 1.355639591871411470e-20 1.679494235371022498e-21 2.269724432941336949e-21 0.000000000000000000e+00 9.421300869707220847e-21 3.526434384799294027e-20 4.950000000000000000e+01 5.236164493883336978e-20 2.606476448121489695e-20 5.500499800127433667e-21 4.363579357163074420e-22 1.481776591646231490e-20 2.554024607530539970e-21 2.892526047123523676e-21 4.122041281398250546e-21 1.436733909089646242e-20 1.278433693800244819e-21 2.238343515209124937e-21 0.000000000000000000e+00 9.355661999647306853e-21 3.552264674649424211e-20 4.960000000000000142e+01 5.129738742044578317e-20 2.605830803695968832e-20 5.387291199033140756e-21 4.322547099045100551e-22 1.480240646509897214e-20 2.539017644253319950e-21 2.881199669932920459e-21 4.106430803451961062e-21 1.175313856081790467e-20 1.581896726793975363e-21 2.210143636905324265e-21 0.000000000000000000e+00 9.290023129587388344e-21 3.450789807438196414e-20 4.970000000000000284e+01 4.826137439825948985e-20 2.605188180740458483e-20 5.269449351625202990e-21 4.282000002218959232e-22 1.478669695481247132e-20 2.524013347259685394e-21 2.869873292742317618e-21 4.090828206116513524e-21 1.266589426203051836e-20 1.629874023433743591e-21 2.168561115507179759e-21 0.000000000000000000e+00 9.224384259527469836e-21 3.477804458022015161e-20 4.980000000000000426e+01 4.514626064620702441e-20 2.604548581491428847e-20 5.294023764634985525e-21 4.242000002168149013e-22 1.477089261376973025e-20 2.509011764384063278e-21 2.858546915551714401e-21 4.075988332699611898e-21 1.131039835362609768e-20 1.692801952474848288e-21 2.139907590101120738e-21 0.000000000000000000e+00 9.158745389467551327e-21 3.427952531125438452e-20 4.990000000000000568e+01 4.596037028341018641e-20 2.603912008177021078e-20 5.462268822200905044e-21 4.202695543520336354e-22 1.475575810870292665e-20 2.494012944603021359e-21 2.847220538361111561e-21 4.061751672538827051e-21 1.241817937947598214e-20 1.779366173109758907e-21 2.110484330982469527e-21 0.000000000000000000e+00 9.094054031578438612e-21 3.465745312498350061e-20 5.000000000000000000e+01 4.485891376964471963e-20 2.603278463017007863e-20 5.610408738853715707e-21 4.163633123089822730e-22 1.474015013868219514e-20 2.479016938069294317e-21 2.835894161170509472e-21 4.047521805766178502e-21 1.204712551726546051e-20 1.171741254185631029e-21 2.084074724883835048e-21 0.000000000000000000e+00 9.030463156270927117e-21 3.449053555467759403e-20 5.010000000000000142e+01 4.617125969552596234e-20 2.602647948222760019e-20 5.461233814144940495e-21 4.124907008392572649e-22 1.472441355766867224e-20 2.464023796147005699e-21 2.824567783979906255e-21 4.033298804284847122e-21 1.159131808479126295e-20 1.506232963658967391e-21 2.068608259512380750e-21 8.862381613695405580e-22 8.966872280963411109e-21 3.430153141308349854e-20 5.020000000000000284e+01 4.999187317503933344e-20 2.602020465997207375e-20 5.455986932450957937e-21 4.086954432357298658e-22 1.470940736013631783e-20 2.449033571448166179e-21 2.813241406789303415e-21 4.019082740980906110e-21 1.038901977661936880e-20 1.493773882534234030e-21 2.052022482245405900e-21 8.131167002257773283e-22 8.903281405655895100e-21 3.387803309943953601e-20 5.030000000000000426e+01 4.754215765917389200e-20 2.601396018534806569e-20 5.309595034877862002e-21 4.049285824717736371e-22 1.469441039704157603e-20 2.434046317870477826e-21 2.801915029598700198e-21 4.004873689739508587e-21 1.323000460991390072e-20 1.175066147143051580e-21 2.035797898314658514e-21 7.254664914917770262e-22 8.839690530348377587e-21 3.478572431944105483e-20 5.040000000000000568e+01 4.761710861901555393e-20 2.600774608021501931e-20 4.914269192612440507e-21 4.011842786699225397e-22 1.467935018471795054e-20 2.419062090636519258e-21 2.790588652408097357e-21 3.990668691589677812e-21 1.137621511358351295e-20 1.554384601547138159e-21 2.019101641360556488e-21 9.941863287887947093e-22 8.776099655040861578e-21 3.405409426812764718e-20 5.050000000000000000e+01 4.912202222911307931e-20 2.600156236634692980e-20 4.579356279702361797e-21 3.974816710707426097e-22 1.466372415476952557e-20 2.404080946334346280e-21 2.779262275217494893e-21 3.976450459140781124e-21 1.293051885781260009e-20 1.683939875560372818e-21 2.009109506611472291e-21 9.815897118625115208e-22 8.713870259012035719e-21 3.453282721032405866e-20 5.060000000000000142e+01 4.919799503876294509e-20 2.599540906543195609e-20 4.647381122969364476e-21 3.938079247088159218e-22 1.464851066279540363e-20 2.389102942959590373e-21 2.767935898026892052e-21 3.962253871572600338e-21 1.195027724477040954e-20 1.338076824666646643e-21 1.997931180759487843e-21 5.986423431384558092e-22 8.652269701262271545e-21 3.413170929368059210e-20 5.070000000000000284e+01 4.634422119963276666e-20 2.598928619907208074e-20 4.798536292159825973e-21 3.902054089814516871e-22 1.463358053833767348e-20 2.374128139959114869e-21 2.756609520836288835e-21 3.948073500526272351e-21 1.187670772499677122e-20 1.685212845587930111e-21 1.979562681537682202e-21 6.762111341220252981e-22 8.590669143512505867e-21 3.411242012991476002e-20 5.080000000000000426e+01 4.524820377304894082e-20 2.598319378878275188e-20 4.855549300710798137e-21 3.866359001724992125e-22 1.461882741294279039e-20 2.359156598276276930e-21 2.745283143645685995e-21 3.933900525691470285e-21 1.123563690923995642e-20 1.502908003766457990e-21 1.972086662648076319e-21 9.547731370251671232e-22 8.529068585762740188e-21 3.387010615836149919e-20 5.090000000000000568e+01 4.497866494333078799e-20 2.597713185599254316e-20 4.788482500490139074e-21 3.831084001686450323e-22 1.460366355585190084e-20 2.344188380397889401e-21 2.733956766455082778e-21 3.919735027297842730e-21 1.294375678053017974e-20 1.358137668665355778e-21 1.956723316184747757e-21 6.394957981322848398e-22 8.467468028012974510e-21 3.442106738911075511e-20 5.100000000000000000e+01 4.587656439600759719e-20 2.597110042204276253e-20 4.749771151027726610e-21 3.796250001648455908e-22 1.458823065884250068e-20 2.329223550402942697e-21 2.722630389264480689e-21 3.905577086696377886e-21 1.170185904172673184e-20 1.124615304522673589e-21 1.942642161209048514e-21 8.080967461959200326e-22 8.405867470263213345e-21 3.393220084876149554e-20 5.110000000000000142e+01 4.713029084930548323e-20 2.596509950818716036e-20 5.002461466001034376e-21 3.761620001611752563e-22 1.457350332474210786e-20 2.314262174013158958e-21 2.711304012073877849e-21 3.891426786378234794e-21 1.169935565509014429e-20 1.396841070351487573e-21 1.928344571919372821e-21 9.254911275607801758e-22 8.345980659816186993e-21 3.395064386715809483e-20 5.120000000000000284e+01 4.862571616995103654e-20 2.595938686848705530e-20 5.286264064761841273e-21 3.727370001576012076e-22 1.455884278725852536e-20 2.300059693489401446e-21 2.700392092431161807e-21 3.877284209993955236e-21 1.238240945972053370e-20 1.327618626847492455e-21 1.923871603254670122e-21 8.974054429122655692e-22 8.286424003836858905e-21 3.420244131505506617e-20 5.130000000000000426e+01 4.560844113031638836e-20 2.595435436107934763e-20 5.410564709126762620e-21 3.693574163031768404e-22 1.454423348143544952e-20 2.287776191974350234e-21 2.690531787369811522e-21 3.864265562073621255e-21 1.310544788654180424e-20 1.217553347228619009e-21 1.924795858488402269e-21 1.058653188886675576e-21 8.226867347857532322e-21 3.446333465095770391e-20 5.140000000000000568e+01 4.880828898244676471e-20 2.594934559776412680e-20 5.374553913275152111e-21 3.660054075581180552e-22 1.452963134201534608e-20 2.275494377257012139e-21 2.680671482308460862e-21 3.851257858896378101e-21 1.135004974637687931e-20 1.793840339110509589e-21 1.914641051493116760e-21 9.464157682710005977e-22 8.167310691878205739e-21 3.382310725631889377e-20 5.150000000000000000e+01 4.804944222305100497e-20 2.594436059229335112e-20 5.335642903770262672e-21 3.627189878016800339e-22 1.451504184154222637e-20 2.263214276798690725e-21 2.670811177247110954e-21 3.838256910446981089e-21 1.315825550735569363e-20 1.105071909436221675e-21 1.907923050880565010e-21 9.389538653423743209e-22 8.107754035898882166e-21 3.440934285831360978e-20 5.160000000000000142e+01 4.638798302472778104e-20 2.593939935836430056e-20 5.238215488031212070e-21 3.594528149588983077e-22 1.450046423839329043e-20 2.250935918656078011e-21 2.660950872185760294e-21 3.825262785597458412e-21 1.278345404831229424e-20 1.178148836488316873e-21 1.896964837453222379e-21 5.989820561396574796e-22 8.048197379919555583e-21 3.421986975004887485e-20 5.170000000000000284e+01 4.318851144596459379e-20 2.593446190961936608e-20 5.136052600736446113e-21 3.562157779187051874e-22 1.448598167603643275e-20 2.238659331497372470e-21 2.651090567124409634e-21 3.812275554122441128e-21 1.150041518108333520e-20 1.522541446384545039e-21 1.887983835163312611e-21 5.961037282634849801e-22 7.989427660638898456e-21 3.373199795610404924e-20 5.180000000000000426e+01 4.646831626125233465e-20 2.592954825964593229e-20 5.287690171578596683e-21 3.530158026069548875e-22 1.447150778584528972e-20 2.226384544618912372e-21 2.641230262063058974e-21 3.799286690409611461e-21 1.196291192909743263e-20 1.207339939825864838e-21 1.889106972097429720e-21 8.560767451012284949e-22 7.930721628444466151e-21 3.388192191262640213e-20 5.190000000000000568e+01 4.768990184670360562e-20 2.592465842197615173e-20 5.694358874274354516e-21 3.498397562323426199e-22 1.445704056702026907e-20 2.214111587962354923e-21 2.631369957001708690e-21 3.786289469441571832e-21 1.242015549544547082e-20 1.057851387705159381e-21 1.875560079696099557e-21 9.221235899690863850e-22 7.872015596250035350e-21 3.408108584218650523e-20 5.200000000000000000e+01 4.356121276289850084e-20 2.591979241008678238e-20 6.052018070817382200e-21 3.467324391562239703e-22 1.444266632096390804e-20 2.201840492132417019e-21 2.621509651940358782e-21 3.773318666109104394e-21 1.175290405365918362e-20 1.451419164155342523e-21 1.874735127268908176e-21 6.198307459192487960e-22 7.813309564055607558e-21 3.388680780035115847e-20 5.210000000000000142e+01 4.626140224714507843e-20 2.591495023739902214e-20 5.856273438184331968e-21 3.436397301902904334e-22 1.442831293047260275e-20 2.189571288415196778e-21 2.611649346879008122e-21 3.760359596008054333e-21 1.106629143170992287e-20 9.811147005701125023e-22 1.870186585882362012e-21 7.641026572330162560e-22 7.754603531861175253e-21 3.357932167991522433e-20 5.220000000000000284e+01 4.815025173516896861e-20 2.591013191727832530e-20 5.615626274722714368e-21 3.405599755862505416e-22 1.441396384423761929e-20 2.177304008797109726e-21 2.601789041817657461e-21 3.747407781383320286e-21 1.157824904874385266e-20 9.755376878426004970e-22 1.862708750788798527e-21 6.292079090723045784e-22 7.695897499666744452e-21 3.368087740686873565e-20 5.230000000000000426e+01 4.868715530975132599e-20 2.590533746303421591e-20 5.319205433435659188e-21 3.375388293916774433e-22 1.439968190441259937e-20 2.165038685984447890e-21 2.591928736756306801e-21 3.734463297724933547e-21 1.033754736013084722e-20 1.395970675961821138e-21 1.868374162891687338e-21 6.996407341284275934e-22 7.638443764039617782e-21 3.321651233940100714e-20 5.240000000000000568e+01 4.554222193925456341e-20 2.590056688792013738e-20 4.964097927822488979e-21 3.345396607267519672e-22 1.438543668215642600e-20 2.152775353423594915e-21 2.582068431694956517e-21 3.721526221530198811e-21 1.216026943364131411e-20 1.851427229640490592e-21 1.867317818180133277e-21 4.913190840353271955e-22 7.581065375910272980e-21 3.376664586829775255e-20 5.250000000000000000e+01 4.805918519446140818e-20 2.589582020513325984e-20 4.651964956256890200e-21 3.315845092089830349e-22 1.437121347649935588e-20 2.140514045321924287e-21 2.572208126633606609e-21 3.708596630319753865e-21 1.043540120433249674e-20 1.640495539972999148e-21 1.857789725801859790e-21 4.594342853328146402e-22 7.523686987780931187e-21 3.310113145265653581e-20 5.260000000000000142e+01 4.706634029635652567e-20 2.589109742781431162e-20 4.732778272294651913e-21 3.286559758730928025e-22 1.435703934195017306e-20 2.128254796669394951e-21 2.562347821572255949e-21 3.695674602653911411e-21 9.962107836687969720e-21 1.493438263491689852e-21 1.855598052640119226e-21 9.193525547711046268e-22 7.466308599651584880e-21 3.294301113999509742e-20 5.270000000000000284e+01 4.799389423285634502e-20 2.588639856904740475e-20 4.903234271516365100e-21 3.257444607190733970e-22 1.434290588603640830e-20 2.115997643260896610e-21 2.552487516510905289e-21 3.682768522978768236e-21 1.175191694327481859e-20 1.776892172262504620e-21 1.851810132075898562e-21 1.026339802414031573e-21 7.408930211522240077e-21 3.354351706539394171e-20 5.280000000000000426e+01 4.663082378888809233e-20 2.588172364185986942e-20 5.061072013745144784e-21 3.228914217973256426e-22 1.432878869749126696e-20 2.103742621719341702e-21 2.542627211449554629e-21 3.670982450146057604e-21 1.038219706385853296e-20 1.244153617279005117e-21 1.855584241678727189e-21 1.040424822718658052e-21 7.351551823392895275e-21 3.306315526853989004e-20 5.290000000000000568e+01 4.644325678765964793e-20 2.587707265922207644e-20 5.173849632120030920e-21 3.200531085419260485e-22 1.431495419051610122e-20 2.091489769519561602e-21 2.532766906388204345e-21 3.659202880015651173e-21 1.129577611104041939e-20 1.163910014961376739e-21 1.841790245400342025e-21 4.573651865227846449e-22 7.296199297539245221e-21 3.333730797703242912e-20 5.300000000000000000e+01 4.505138671456552604e-20 2.587244563404725669e-20 5.261789112489726945e-21 3.172434699853832279e-22 1.430156196743091392e-20 2.079239125013025856e-21 2.522906601326854437e-21 3.647429875590025769e-21 1.007324151150627462e-20 8.567000134863305080e-22 1.840350478545697646e-21 1.147921404897250918e-21 7.241091982116055242e-21 3.293993593839129564e-20 5.310000000000000142e+01 4.730376067622722571e-20 2.586784257919135367e-20 5.060193837149093100e-21 3.144585061276994487e-22 1.428767091071949949e-20 2.066990727453413791e-21 2.513046296265503777e-21 3.635644041730126428e-21 1.090475717409403268e-20 1.322921883281761129e-21 1.820108114311014982e-21 1.306334388772221994e-21 7.185984666692862252e-21 3.316797484890205466e-20 5.320000000000000284e+01 4.725336549754925931e-20 2.586326350745283389e-20 4.869284835702785543e-21 3.116874217881272657e-22 1.427367385319746807e-20 2.054744617023092292e-21 2.503185991204153116e-21 3.623865020251494797e-21 1.197114834366765323e-20 8.774462681901028924e-22 1.807980139132359450e-21 9.130734160706844597e-22 7.130877351269669263e-21 3.345300843394191881e-20 5.330000000000000426e+01 4.659838846538560395e-20 2.585870843157251838e-20 5.006995958454267582e-21 3.089906667658819385e-22 1.425977061830244081e-20 2.042500834860508392e-21 2.493325686142802456e-21 3.612111972575910108e-21 9.918413685644279305e-21 9.100168771705880739e-22 1.790645643903460528e-21 7.217316141633099971e-22 7.075770035846476274e-21 3.276602004878264001e-20 5.340000000000000568e+01 4.462076318517574911e-20 2.585417736423341716e-20 5.487928963573090745e-21 3.063020839294356307e-22 1.424586974325181792e-20 2.030259423088560253e-21 2.483465381081452172e-21 3.600365749788130045e-21 1.251622042520566678e-20 8.484134802685601672e-22 1.775311607503378485e-21 6.764949566153975493e-22 7.020662720423283285e-21 3.369156163321817977e-20 5.350000000000000000e+01 4.540630574890608280e-20 2.584967031806056978e-20 5.963947688805696418e-21 3.036290300351372413e-22 1.423197594856588329e-20 2.018020424843970230e-21 2.473605076020102264e-21 3.588626418905429510e-21 1.076652894547493527e-20 1.167790102802498914e-21 1.751860644440967987e-21 7.974757484282287305e-22 6.967251652332471065e-21 3.315138434197117269e-20 5.360000000000000142e+01 4.427837712430591335e-20 2.584524811520280576e-20 5.779349717900927652e-21 3.009997634066062782e-22 1.421870928241347895e-20 2.005964222753767943e-21 2.463851560614837413e-21 3.576894047785300434e-21 9.718684128761101337e-21 1.397835002271984664e-21 1.738070910155656596e-21 4.804657629831120855e-22 6.914345340232060484e-21 3.277186795147140778e-20 5.370000000000000284e+01 4.624315582073589789e-20 2.584151306732149154e-20 5.540071290339830758e-21 2.983962131087624388e-22 1.420522946261678601e-20 1.995884784674395420e-21 2.455267561135855041e-21 3.565168705137971830e-21 1.091375098075591586e-20 1.205444170410283705e-21 1.717944971228457856e-21 7.459172928997847935e-22 6.861439028131649902e-21 3.307909043262005692e-20 5.380000000000000426e+01 4.361029093045892885e-20 2.583779681057476612e-20 5.309396271013433321e-21 2.958139048509809791e-22 1.419144135761518656e-20 1.985806527414698662e-21 2.446683561656872670e-21 3.553450460539129956e-21 1.094494387879811982e-20 1.240311546232509405e-21 1.695171103422487948e-21 6.487251637141424499e-22 6.808532716031239321e-21 3.302731265249693004e-20 5.390000000000000568e+01 4.284059116063697710e-20 2.583409935307200128e-20 5.089588510190076302e-21 2.932506353813259264e-22 1.417772203324531465e-20 1.975729469044869221e-21 2.438099562177889922e-21 3.541739384442861166e-21 1.147141132989181827e-20 1.189948255750910871e-21 1.675049457882306220e-21 4.670166148981004918e-22 6.755626403930828740e-21 3.314305041659863450e-20 5.400000000000000000e+01 4.461299916857393363e-20 2.583042070288615369e-20 4.886063549143627662e-21 2.907376942030069540e-22 1.416413676705309854e-20 1.965653628003482779e-21 2.429515562698908302e-21 3.530035548194803907e-21 1.128482650363387099e-20 8.911290029300966166e-22 1.674570476819363335e-21 6.019959829343356349e-22 6.702720091830421920e-21 3.301898700255484838e-20 5.410000000000000142e+01 4.550472384617988727e-20 2.582676086805372877e-20 4.828523699817765353e-21 2.882445177306216119e-22 1.415106426773221026e-20 1.955579023106869250e-21 2.420931563219925554e-21 3.518339024045525654e-21 1.154005653764514225e-20 1.050598229591954256e-21 1.643924707063972049e-21 6.722946398747244380e-22 6.651044559219335095e-21 3.308176771411169941e-20 5.420000000000000284e+01 4.449109582660544001e-20 2.582311985657465132e-20 4.824239119389826830e-21 2.857668706700372984e-22 1.413765630090423213e-20 1.945505673558783056e-21 2.412347563740943183e-21 3.506649885164129307e-21 1.062014600120671159e-20 7.400088907313619102e-22 1.615281680859521221e-21 6.418793456818916254e-22 6.600266305587115784e-21 3.273961775371101054e-20 5.430000000000000426e+01 4.704221734142197999e-20 2.581949767641221734e-20 4.955112563161433789e-21 2.833216000800653683e-22 1.412398515234055679e-20 1.935433598960358149e-21 2.403763564261960435e-21 3.495510767797726916e-21 1.197350176380543084e-20 1.091734836276728055e-21 1.588794968510291277e-21 5.590748420485415163e-22 6.549488051954897225e-21 3.320841254591040560e-20 5.440000000000000568e+01 4.732237355748045756e-20 2.581589433549299175e-20 5.192625392275218299e-21 2.808891228854164567e-22 1.411096529278527222e-20 1.925362819320376759e-21 2.395179564782978063e-21 3.484771447555262765e-21 1.070381617414592504e-20 1.106301749982751790e-21 1.555731961286308177e-21 1.137267877831045186e-21 6.498709798322677913e-21 3.280170775479090547e-20 5.450000000000000000e+01 4.776371929645891228e-20 2.581230984170670607e-20 5.397799518866994280e-21 2.784961404276305765e-22 1.409782809700697205e-20 1.915293355065852224e-21 2.386595565303996068e-21 3.474030908703252219e-21 1.129368957366106165e-20 1.256219890295937770e-21 1.538235360310454791e-21 8.675216144468197608e-22 6.447931544690463116e-21 3.300743960875044369e-20 5.460000000000000142e+01 4.912412434437509049e-20 2.580874420290623733e-20 5.319021766502999651e-21 2.761200000751564288e-22 1.408433313837885829e-20 1.905225227052942470e-21 2.378011565825013696e-21 3.463279733978806822e-21 9.586921860397363102e-21 7.341246780152188169e-22 1.516473184669178501e-21 4.378466697004496577e-22 6.397153291058243804e-21 3.240324152666155470e-20 5.470000000000000284e+01 4.567607487619193863e-20 2.580519742690744257e-20 5.213225205716086191e-21 2.737644445180403886e-22 1.407125490659311360e-20 1.895158456578209554e-21 2.369427566346031324e-21 3.452551593728760920e-21 9.391774047077658394e-21 9.711950231451411845e-22 1.482034273727220156e-21 9.492500691090972722e-22 6.347045140949844743e-21 3.232364677457434424e-20 5.480000000000000426e+01 4.483772955125782042e-20 2.580166952148914983e-20 5.021238753232971143e-21 2.714431163511211084e-22 1.405836213509482428e-20 1.885093065390220006e-21 2.360843566867048577e-21 3.441838234223227098e-21 1.049913864585019624e-20 1.052582214024385269e-21 1.466689196091980345e-21 8.698992483049864385e-22 6.298399141316272488e-21 3.261197939267850263e-20 5.490000000000000568e+01 4.622101892233997117e-20 2.579816049439301971e-20 4.738704807217658984e-21 2.691347746370334165e-22 1.404488436289677102e-20 1.875029075701527725e-21 2.352259567388066205e-21 3.431131548933462980e-21 1.123371168287833374e-20 1.781811107597735465e-21 1.419854095253481126e-21 5.839002272303686460e-22 6.249753141682700233e-21 3.281677329823861988e-20 5.500000000000000000e+01 4.587119779051767018e-20 2.579467035332349723e-20 4.497593357017381796e-21 2.668735029592586007e-22 1.403169019744950199e-20 1.864966510201025509e-21 2.343675567909084209e-21 3.420431600534654662e-21 1.041941969282268697e-20 1.183011613635834277e-21 1.392963607518091171e-21 7.372868957100841926e-22 6.201107142049131740e-21 3.246728624431095862e-20 5.510000000000000142e+01 4.205134644088345634e-20 2.579119910594773355e-20 4.697031602646042178e-21 2.646216185647616109e-22 1.401891421614842810e-20 1.854905392066691550e-21 2.335091568430101838e-21 3.409738452449013584e-21 9.658053054763726110e-21 1.623173003418972149e-21 1.398293364283026625e-21 1.187533205430480222e-21 6.152461142415559486e-21 3.227225739739019032e-20 5.520000000000000284e+01 4.406245890838935920e-20 2.578774675989546567e-20 4.941409830199085590e-21 2.623927168292678162e-22 1.400619757089621725e-20 1.844845744978754598e-21 2.326507568951119466e-21 3.399052168856275856e-21 1.132184056559491258e-20 9.542454166937214378e-22 1.385634707755124300e-21 7.792935590319800561e-22 6.103815142781987231e-21 3.278591134516229759e-20 5.530000000000000426e+01 4.665518427954375224e-20 2.578431332275897424e-20 4.965430282072284338e-21 2.601890115591429839e-22 1.399345492523559972e-20 1.834787593133270259e-21 2.317923569472136718e-21 3.388372814704359574e-21 9.435781423791730618e-21 1.314485550487047880e-21 1.375642762200310422e-21 1.237220505120586922e-21 6.055169143148414976e-21 3.219380530902730137e-20 5.540000000000000568e+01 4.385090444720408786e-20 2.578089880209299332e-20 4.766488337360909741e-21 2.580051035118362155e-22 1.398016398459009839e-20 1.824730961256144552e-21 2.309339569993154346e-21 3.377700455720187264e-21 9.434019970808085470e-21 1.385282131021216994e-21 1.381118200613763707e-21 9.262228476755814077e-22 6.008537690049959709e-21 3.213634856817131504e-20 5.550000000000000000e+01 4.998205181773058742e-20 2.577750320541462608e-20 4.574870015540543824e-21 2.558475862691446933e-22 1.396714057068908910e-20 1.814675874617614491e-21 2.300755570514172351e-21 3.367035158420685128e-21 1.029608094717583392e-20 1.313179334573691548e-21 1.386235893355872477e-21 3.765351563546532166e-22 5.961952450778843917e-21 3.233915675915421759e-20 5.560000000000000142e+01 4.571290877779162355e-20 2.577412654020325457e-20 4.469405062885025999e-21 2.536992229181074504e-22 1.395446977553077429e-20 1.804622359047195862e-21 2.292171571035189979e-21 3.356376990123945911e-21 9.571475450197817262e-21 1.152826969226273190e-21 1.372691916787086873e-21 7.719421558846660455e-22 5.915367211507724363e-21 3.208212350765253934e-20 5.570000000000000284e+01 4.500513045557086295e-20 2.577076881390047048e-20 4.371129606079041383e-21 2.515895086311451605e-22 1.394185691827904904e-20 1.794570440949131662e-21 2.283587571556207231e-21 3.345726018960574210e-21 1.035567695089276598e-20 8.535987601749042188e-22 1.357266892407024705e-21 1.314519188348366470e-21 5.868781972236605561e-21 3.229997710011172860e-20 5.580000000000000426e+01 4.572227277620720165e-20 2.576743003391000892e-20 4.195440322316110486e-21 2.494903543442012168e-22 1.392926641109608115e-20 1.784520147318345722e-21 2.275003572077224860e-21 3.335080042068820735e-21 9.451351048653971918e-21 1.291325414254890814e-21 1.352019771057441106e-21 8.432351696188554965e-22 5.822196732965486007e-21 3.197755973046220546e-20 5.590000000000000568e+01 4.569330286670905189e-20 2.576411020759764614e-20 3.950019478912117716e-21 2.474126400572944630e-22 1.391668422297907866e-20 1.774471505756925958e-21 2.266419572598242488e-21 3.325059723581905785e-21 9.296980464170556733e-21 9.724383089648867844e-22 1.342443108053333880e-21 1.080027469543824230e-21 5.775611493694367205e-21 3.187749289693464953e-20 5.600000000000000000e+01 4.564575755928256413e-20 2.576080934229113633e-20 3.743253800475459950e-21 2.453589091470308374e-22 1.390389000437936461e-20 1.764424544491162834e-21 2.257835573119260492e-21 3.315330388073970376e-21 9.455153283273325963e-21 7.841896124713928409e-22 1.349281969073994838e-21 8.704564132298358602e-22 5.730154817979593884e-21 3.186910484559108744e-20 5.610000000000000142e+01 4.432036439694410325e-20 2.575752744528010626e-20 3.827516728423669234e-21 2.433225455095233375e-22 1.389079894272562881e-20 1.754379292389155817e-21 2.249251573640278121e-21 3.305621972792890089e-21 8.919544323556551396e-21 9.604962430954042259e-22 1.342237996828539630e-21 8.754294193559480766e-22 5.685558484447286185e-21 3.171044150213877126e-20 5.620000000000000284e+01 4.535856581508998215e-20 2.575469164307625475e-20 3.937935723373440344e-21 2.413104091447765077e-22 1.387819974392340475e-20 1.745626257411420787e-21 2.241490094666307676e-21 3.295919848929964189e-21 9.648472171125963265e-21 1.061992708125999345e-21 1.338560596486601263e-21 5.713296003953117561e-22 5.640962150914978487e-21 3.191501487517585893e-20 5.630000000000000426e+01 4.337774999934634050e-20 2.575202115765027792e-20 4.101355897479750008e-21 2.393058983578579493e-22 1.386577566098824197e-20 1.737326929524934145e-21 2.234017197367825857e-21 3.286224072208827549e-21 1.219416244039259822e-20 1.510943555044061249e-21 1.337326643699543877e-21 6.726007223772293044e-22 5.596365817382670788e-21 3.279716169032810899e-20 5.640000000000000568e+01 4.485962953876738710e-20 2.574936561340934609e-20 4.322637279143501929e-21 2.373375367748730816e-22 1.385336988706026319e-20 1.729028433867236326e-21 2.226544300069344038e-21 3.276534698976026236e-21 9.837547783075754882e-21 1.421874854449605432e-21 1.345849450760941432e-21 1.012299283426853701e-21 5.551769483850363089e-21 3.201292249739459106e-20 5.650000000000000000e+01 4.625507998210217467e-20 2.574672501497660592e-20 4.545593301241076905e-21 2.353783503331465131e-22 1.384096523875345756e-20 1.720730782478992324e-21 2.219071402770862972e-21 3.266851786209158331e-21 1.144140318770324201e-20 4.920190970170901915e-22 1.359999600459625233e-21 5.888086177104466716e-22 5.507173150318058400e-21 3.251791110110336145e-20 5.660000000000000142e+01 4.373342068823703335e-20 2.574409936695107883e-20 4.733833992750728636e-21 2.334416271682784837e-22 1.382856076968659327e-20 1.712433987633000749e-21 2.211598505472381530e-21 3.257175391525134358e-21 9.551713759339304509e-21 6.801684530917683049e-22 1.344148516865841547e-21 5.784372945746885477e-22 5.462741198077468060e-21 3.191496428455470045e-20 5.670000000000000284e+01 4.414799430533498695e-20 2.574148867390761880e-20 4.925409668454076436e-21 2.315301006072940756e-22 1.381621284233667922e-20 1.704138061839790687e-21 2.204125608173899711e-21 3.247505573188559596e-21 8.385787796189515292e-21 1.174418992945260223e-21 1.354447697793216056e-21 4.859024483867545278e-22 5.420125751641010438e-21 3.161143593028131052e-20 5.680000000000000426e+01 6.577259081004949905e-20 2.573889294039686426e-20 5.036548876415068915e-21 2.296418324498825298e-22 1.380389719099911523e-20 1.695843017853367509e-21 2.196652710875417892e-21 3.237842390120231115e-21 9.167291512768431709e-21 2.439517723362827847e-21 1.346424841892195116e-21 3.481663923683518810e-22 5.377510305204552816e-21 3.189803621864784232e-20 5.690000000000000568e+01 6.091463020849999767e-20 2.573631217094522905e-20 5.064332907679444951e-21 2.277655056646785428e-22 1.379165044546782259e-20 1.687548868677134735e-21 2.189179813576936450e-21 3.228185901905763462e-21 8.526625864619622322e-21 1.810829381572533593e-21 1.350832169126416788e-21 6.565811493818656626e-22 5.334894858768095194e-21 3.167061170780647165e-20 5.700000000000000000e+01 4.757357080598355374e-20 2.573374637005481818e-20 5.098406106803355522e-21 2.258935955513842031e-22 1.377940776444912306e-20 1.679255627569984037e-21 2.181706916278455008e-21 3.218536168804331324e-21 1.068064065753065306e-20 8.878650392956030374e-22 1.361532699032170642e-21 6.812784753115166002e-22 5.292279412331640582e-21 3.226874331513052971e-20 5.710000000000000142e+01 4.656241771681533329e-20 2.573119554220343982e-20 5.162458655197926567e-21 2.240592179219454003e-22 1.376716789513562675e-20 1.670963308052562778e-21 2.174234018979973565e-21 3.208893251757541980e-21 1.004463882426925379e-20 9.302145364568744244e-22 1.362644360751762953e-21 6.619326392643277797e-22 5.249663965895182960e-21 3.205871051761958809e-20 5.720000000000000284e+01 4.486185602631925994e-20 2.572865969184451507e-20 5.233325472660596325e-21 2.222323555995087089e-22 1.375493279535223671e-20 1.662671923913731155e-21 2.166761121681491746e-21 3.199257212398436758e-21 1.070731482320353224e-20 1.174337595398664306e-21 1.362709112368344670e-21 9.134674843786122802e-22 5.207048519458725338e-21 3.228194820061617680e-20 5.730000000000000426e+01 4.386569969039744460e-20 2.572613882340709600e-20 5.256468769465486790e-21 2.204345778208447234e-22 1.374271505363066689e-20 1.654381489217204201e-21 2.159288224383009928e-21 3.189628113060618141e-21 8.652389365505643182e-21 1.225213521536977341e-21 1.358295274920081320e-21 9.648616441507690939e-22 5.165431821656976592e-21 3.165077127397526956e-20 5.740000000000000568e+01 4.154518816426730041e-20 2.572363294129577838e-20 5.232829132604167996e-21 2.186464000422132021e-22 1.373055496800185995e-20 1.646092018308393923e-21 2.151815327084528485e-21 3.179984427397743942e-21 8.297427635005505090e-21 1.365406185228399070e-21 1.359510423744563053e-21 4.770763480657506215e-22 5.124724656413917368e-21 3.153040247360079308e-20 5.750000000000000000e+01 4.623544710163547201e-20 2.572114204989068962e-20 5.201768749801175487e-21 2.168752889302582687e-22 1.371841395705454664e-20 1.637803525821455871e-21 2.144342429786047043e-21 3.170618230664268340e-21 8.468669771942152538e-21 9.256838053445006159e-22 1.361550808427758218e-21 3.174622124644029243e-22 5.084017491170861153e-21 3.153708900009008782e-20 5.760000000000000142e+01 4.532015828633952326e-20 2.571866615354744669e-20 5.023780039851255393e-21 2.151232707587877109e-22 1.370633883431560218e-20 1.629516026686544475e-21 2.136869532487565601e-21 3.161771256988884404e-21 8.664154988546798718e-21 1.137964015509710756e-21 1.373181246815625293e-21 9.886975476681721192e-22 5.043310325927801929e-21 3.156702647728931398e-20 5.770000000000000284e+01 4.299400651373069061e-20 2.571620525659711997e-20 4.930550013847547675e-21 2.133862541833988510e-22 1.369426953339140173e-20 1.621229536137290694e-21 2.129396635189083782e-21 3.152930377716337821e-21 8.587105814326256606e-21 1.542624433761002074e-21 1.370277405049666265e-21 7.666321531781466537e-22 5.002603160684742705e-21 3.152658042048167260e-20 5.780000000000000426e+01 4.877110347535164781e-20 2.571375936334619414e-20 4.727768702939959748e-21 2.116778242147871918e-22 1.368220890194943649e-20 1.612944069718503670e-21 2.121923737890601963e-21 3.144095644257162913e-21 9.097537270963451678e-21 1.877093618312961370e-21 1.375500686834650535e-21 6.989754194718673703e-22 4.961895995441683481e-21 3.163978503843999352e-20 5.790000000000000568e+01 5.980593684436915194e-20 2.571132847807652905e-20 4.335284557657599092e-21 2.099789231151152781e-22 1.367015215516820994e-20 1.604659643294104843e-21 2.114450840592120521e-21 3.135267108565424911e-21 1.023967613861216312e-20 1.271331869040744727e-21 1.381352675592271030e-21 4.873958320728210739e-22 4.921188830198624258e-21 3.188245648826368710e-20 5.800000000000000000e+01 5.624127929046529536e-20 2.570891260504532665e-20 3.961624011314680768e-21 2.083004615758911379e-22 1.365809495764109939e-20 1.596376273055309766e-21 2.106977943293639455e-21 3.126444823145372689e-21 9.242469331609988486e-21 1.626146390139160729e-21 1.390749459384835951e-21 7.246602028749507938e-22 4.881617389377021077e-21 3.153330185404918353e-20 5.810000000000000142e+01 4.919234907559326298e-20 2.570651174848509182e-20 3.747974014734317798e-21 2.066261978389019984e-22 1.364616261148569502e-20 1.588093975529055368e-21 2.099505045995157636e-21 3.117628841058178012e-21 9.737758810181427561e-21 9.986585813373132259e-22 1.385500527633494805e-21 9.231712256753054254e-22 4.842189574525410551e-21 3.161996204465958896e-20 5.820000000000000284e+01 4.679938667588429369e-20 2.570412591260360535e-20 3.585858930648367369e-21 2.049734505854339374e-22 1.363423857925191963e-20 1.579812767586690523e-21 2.092032148696675817e-21 3.108819215928770708e-21 8.949597652024748957e-21 1.145410594969447881e-21 1.383329784827885373e-21 8.479768635604526219e-22 4.802761759673799273e-21 3.135504047041147297e-20 5.830000000000000426e+01 4.698540548174342163e-20 2.570175510158386670e-20 3.630009661568985987e-21 2.033309289970265185e-22 1.362226385731966236e-20 1.571532666452937455e-21 2.084559251398194375e-21 3.100016001952756595e-21 9.258549693712183203e-21 1.126279207730564930e-21 1.374778811735810634e-21 1.038071533981216048e-21 4.763333944822187994e-21 3.143940218519018642e-20 5.840000000000000568e+01 4.520990013636910782e-20 2.569939931958408802e-20 3.863475619562196824e-21 2.017134426575341376e-22 1.361032290576289097e-20 1.563253689715128115e-21 2.077086354099712556e-21 3.091219253903432075e-21 8.031159823057958674e-21 1.481338866991546180e-21 1.371458031095734688e-21 6.758947399316193797e-22 4.723906129970576715e-21 3.111796500988825422e-20 5.850000000000000000e+01 4.697115200444420765e-20 2.569705857073762793e-20 4.108029492349308702e-21 2.001100000339050777e-22 1.359842227631866158e-20 1.554975855332733584e-21 2.069613456801231490e-21 3.082429027138888637e-21 9.741850595672086214e-21 1.047643746108136471e-21 1.366220130064756599e-21 5.910197057836341137e-22 4.684478315118968446e-21 3.159961844171711860e-20 5.860000000000000142e+01 4.569585914536777329e-20 2.569473285915297046e-20 4.375055470443352735e-21 1.985230435115059866e-22 1.358696063440092302e-20 1.546699181647191768e-21 2.062140559502749671e-21 3.073645377609208385e-21 9.055993550140608435e-21 1.250975607920081941e-21 1.361277874653645396e-21 1.466906622280632307e-21 4.645346735145438772e-21 3.145246275949227110e-20 5.870000000000000284e+01 4.465772678105297459e-20 2.569242218891370100e-20 4.643567184012914512e-21 1.969495652499849669e-22 1.357570090394849446e-20 1.538423687392045432e-21 2.054667662204267853e-21 3.064868361863764143e-21 9.719544205985015742e-21 1.277355612619223427e-21 1.369795305941046571e-21 3.103966326903672429e-21 4.607609951826400416e-21 3.179348574079639091e-20 5.880000000000000426e+01 4.739904770401969686e-20 2.569021773397979052e-20 4.715620790161566971e-21 1.953843478580511777e-22 1.356391960464569376e-20 1.530431404079054247e-21 2.047386666762921817e-21 3.056073732417756683e-21 9.659106304784602542e-21 1.321326561288391732e-21 1.365395224555155502e-21 4.989962943635993673e-21 4.569873168507362059e-21 3.201262359456680538e-20 5.890000000000000568e+01 5.698765492416008067e-20 2.568839484264783570e-20 4.598040936572905752e-21 1.938442811124198237e-22 1.355211308265044277e-20 1.523579419326293478e-21 2.040881051965252257e-21 3.047288333416841719e-21 9.375755472943847161e-21 9.358138621862734658e-22 1.351988909078188799e-21 2.369257373340527093e-21 4.532136385188323703e-21 3.157954185160273001e-20 5.900000000000000000e+01 6.460024330015492010e-20 2.568658390222377507e-20 4.517117459119015776e-21 1.923113081388433962e-22 1.354036158496114376e-20 1.516728008887332463e-21 2.034375437167583450e-21 3.038531431489281076e-21 9.479743553660066281e-21 1.740505158685770363e-21 1.344434768404158017e-21 1.655490217216297383e-21 4.494399601869288356e-21 3.157368865473716916e-20 5.910000000000000142e+01 5.239254571497345213e-20 2.568478491523545788e-20 4.737382143899711170e-21 1.908080000301371998e-22 1.352884637847839620e-20 1.509877180580407641e-21 2.027869822369914266e-21 3.029781395022280953e-21 9.363433177808256043e-21 1.201498765014783486e-21 1.352716770684138266e-21 3.726022788213174498e-21 4.456662818550249247e-21 3.170932087382137534e-20 5.920000000000000284e+01 4.726939164659839127e-20 2.568299788419474817e-20 4.986364101565339563e-21 1.893082795994451616e-22 1.351767077262591031e-20 1.503026942365629529e-21 2.021364207572244706e-21 3.021446908967619104e-21 8.812360852637803561e-21 8.017025611415233053e-22 1.381542353926660999e-21 1.137171464326261852e-21 4.418926035231211643e-21 3.136473766829656906e-20 5.930000000000000426e+01 4.758016392798614665e-20 2.568122281159750971e-20 5.160246069117729462e-21 1.878265591687676969e-22 1.350618190609730383e-20 1.496177302348197562e-21 2.014858592774575146e-21 3.013475176245641743e-21 9.166551021955084991e-21 9.270658332776395236e-22 1.396188885745501607e-21 6.282160122836615252e-22 4.381916090650448952e-21 3.147086118113191073e-20 5.940000000000000568e+01 5.097883813512880818e-20 2.567945969992360601e-20 5.263080876453262843e-21 1.863498064800359345e-22 1.349451042176891299e-20 1.489328268781705017e-21 2.008352977976905963e-21 3.005509303043192407e-21 8.016062967835268124e-21 1.049063718901382667e-21 1.392892930205055589e-21 9.896223822191400536e-22 4.346068089345434055e-21 3.117244755092162434e-20 5.950000000000000000e+01 7.043259486523599010e-20 2.567770855163684916e-20 5.636388870664657427e-21 1.848917419633621192e-22 1.348284335381076009e-20 1.482479850071533653e-21 2.001847363179237155e-21 2.997549336074623862e-21 7.410623848924853342e-21 9.247701588023294481e-22 1.416699657357202067e-21 2.842872999155340810e-21 4.310220088040420663e-21 3.118597112340793594e-20 5.960000000000000142e+01 5.999494304760417637e-20 2.567596936918501486e-20 8.222560364790607539e-21 1.834465532188271112e-22 1.347122538369749229e-20 1.475632054778340135e-21 1.995341748381567595e-21 2.989595322516981128e-21 9.884282365394102220e-21 9.794009486830994328e-22 1.430877489963040386e-21 8.865808756287792435e-22 4.274372086735405014e-21 3.229910190231074861e-20 5.970000000000000284e+01 4.951263170908654648e-20 2.567424215499982440e-20 1.114512022162754271e-20 1.820252766225611392e-22 1.346019252825364638e-20 1.468784891621642324e-21 1.988836133583898412e-21 2.981647310015248888e-21 9.121510427149763484e-21 1.349787252761537204e-21 1.440577414762527192e-21 5.963308807016765218e-22 4.238524085430389365e-21 3.293953837446431564e-20 5.980000000000000426e+01 8.847667808818290423e-20 2.567252691149689345e-20 1.458278532873782900e-20 1.806094759621298822e-22 1.344900307336471048e-20 1.461938369483500548e-21 1.982330518786228852e-21 2.973705346687644787e-21 1.207172198858032463e-20 5.280801411791676980e-21 1.464736568404048523e-21 2.876133436055518988e-21 4.202676084125373716e-21 3.562650430973845331e-20 5.990000000000000568e+01 1.420042736397246821e-18 2.567082364107575921e-20 1.852262461682338095e-20 1.791998502931783812e-22 1.343741195803683631e-20 1.455092497412304766e-21 1.975824903988559292e-21 2.965769481130986080e-21 3.526288282643564541e-19 3.576455307863906688e-19 1.481937314962939356e-21 6.155201050219804462e-20 4.166828082820358067e-21 5.072111165329263771e-19 6.000000000000000000e+01 3.631909355126112193e-18 2.566913234611983821e-20 2.162088912441547918e-20 1.778118730411783221e-22 1.342613100338791064e-20 1.448247284626663478e-21 1.969319289190890485e-21 2.957826826205167891e-21 7.102120259942275408e-19 2.062232760705260304e-18 1.540444302785656471e-21 1.698659281604942008e-19 4.131908977752683472e-21 2.188012875778853679e-18 6.010000000000000142e+01 2.306187420605551835e-18 2.566745302899640532e-20 1.819128458311352672e-20 1.764383280671501069e-22 1.341516997576282476e-20 1.441402740519405860e-21 1.962813674393221301e-21 2.949876798414649985e-21 6.290371799623600290e-19 6.053392054489074955e-19 1.455408163420332590e-21 2.599595755526136920e-19 4.097862036674076401e-21 9.115402294931641408e-19 6.020000000000000284e+01 1.494249391003558043e-19 2.566578569205660269e-20 1.391664869961284372e-20 1.750783069026588967e-22 1.340387322549375071e-20 1.434558874661694489e-21 1.956308059595551741e-21 2.941951188620631493e-21 1.343974992784091412e-20 1.556297077496460433e-20 1.403404253541814868e-21 4.934687395790671363e-21 4.063815095595469329e-21 3.888841121789794140e-20 6.030000000000000426e+01 5.996822081130827192e-20 2.566413033763539470e-20 1.040542639576620236e-20 1.737238095476983188e-22 1.339242615966320671e-20 1.427715696807254490e-21 1.949802444797882557e-21 2.934040081062741512e-21 9.398002441923964075e-21 2.635470575865103798e-21 1.367004045421279723e-21 3.118309571234066166e-22 4.029768154516862257e-21 3.277544142785340282e-20 6.040000000000000568e+01 5.189610449865787836e-20 2.566248696805157993e-20 7.660873919398438836e-21 1.723849312403698706e-22 1.338146299294641420e-20 1.420873216896724560e-21 1.943296830000212998e-21 2.926135321038781191e-21 8.687650813751193209e-21 9.799203617170404645e-22 1.324650214255733660e-21 7.613324795410566885e-22 3.995721213438254433e-21 3.170865307928570891e-20 6.050000000000000000e+01 4.667214179275236758e-20 2.566085558560774906e-20 5.187934142542487712e-21 1.710494815044740383e-22 1.337052820966548043e-20 1.414031445062129296e-21 1.936791215202544190e-21 2.918236960130305553e-21 8.401594742629612559e-21 1.482048534870142673e-21 1.288786123553221255e-21 5.890174720706652261e-22 3.961674272359649618e-21 3.112791739021058727e-20 6.060000000000000142e+01 4.578470932659273619e-20 2.565923619259029090e-20 4.653742371979108628e-21 1.697401473909798120e-22 1.335909531129160129e-20 1.407190391631481870e-21 1.930285600404874630e-21 2.910345050436830797e-21 8.608276073884877418e-21 1.636532682511833134e-21 1.265616598762586017e-21 6.268634709896387350e-22 3.927627331281042546e-21 3.109543231313289757e-20 6.070000000000000284e+01 4.121193032085411483e-20 2.565762879126934721e-20 4.407584159877136978e-21 1.684335497603505246e-22 1.334782249491741878e-20 1.400350067133521179e-21 1.923779985607205447e-21 2.902459644581731334e-21 8.243941345389808452e-21 1.358831233551443179e-21 1.211889515295193345e-21 4.328199112677607513e-22 3.894577191486201390e-21 3.092979732016150859e-20 6.080000000000000426e+01 4.129930546958293908e-20 2.565603338389883984e-20 4.186772240581980078e-21 1.671518743672633382e-22 1.333700094064986366e-20 1.393510482302582149e-21 1.917274370809535887e-21 2.894580795718202270e-21 8.172267834244584398e-21 1.291269471650525684e-21 1.180619703970858178e-21 5.984484882997524495e-22 3.862288089924712857e-21 3.086719401341175143e-20 6.090000000000000568e+01 4.235800427769551009e-20 2.565444997271641349e-20 3.965572015335353797e-21 1.658730000213048426e-22 1.332620622149715648e-20 1.386671648083610865e-21 1.910768756011866703e-21 2.886843951217320968e-21 7.395083409168737565e-21 1.088293391596174773e-21 1.148715945280379549e-21 7.387414449546519398e-22 3.829998988363224325e-21 3.062360911208390486e-20 6.100000000000000000e+01 5.213946150184740659e-20 2.565287855994345683e-20 3.788013616320146030e-21 1.646146666875707506e-22 1.331544956470178939e-20 1.379833575637324900e-21 1.904263141214197519e-21 2.879596248327290306e-21 8.458812773885805488e-21 1.191936020988862033e-21 1.123703023722655766e-21 7.976685824123515156e-22 3.797709886801738049e-21 3.086848818920437622e-20 6.110000000000000142e+01 5.560423061055461203e-20 2.565131914778503626e-20 3.892216036225388747e-21 1.633605000205125179e-22 1.330436301235866635e-20 1.372996276345524478e-21 1.897757526416528336e-21 2.872354245848537489e-21 8.375353352786064525e-21 1.162057728958333400e-21 1.099548747006737911e-21 6.531995661991451980e-22 3.765420785240249516e-21 3.084185947035349865e-20 6.120000000000000284e+01 4.044777914488211793e-20 2.564977173842994409e-20 4.031922329349651687e-21 1.621230000201256079e-22 1.329306953978402081e-20 1.366159761816563695e-21 1.891251911618858776e-21 2.865117987006919693e-21 6.713174570887052166e-21 7.374293683594123434e-22 1.082945106279839860e-21 4.626100859396049288e-22 3.733131683678760983e-21 3.042178269238432334e-20 6.130000000000000426e+01 3.875242876190200881e-20 2.564823633405063530e-20 4.112398300192140701e-21 1.608901666864183291e-22 1.328224510641397301e-20 1.359324043890980668e-21 1.884746296821189592e-21 2.857887515431633477e-21 7.760566862201861681e-21 7.888960404140796785e-22 1.074050868636697781e-21 8.501670046962650101e-22 3.700842582117271698e-21 3.067860295152089810e-20 6.140000000000000568e+01 3.911255067380026565e-20 2.564671293680324264e-20 4.133781589517019024e-21 1.596693333527143322e-22 1.327155260281607724e-20 1.352489134647295824e-21 1.878240682023520032e-21 2.850662875159452206e-21 7.476977079933106591e-21 8.756990653273091451e-22 1.071611439468775198e-21 5.003162453847921045e-22 3.669452270536507673e-21 3.059445233567532915e-20 6.150000000000000000e+01 4.263003832805217908e-20 2.564520154882752544e-20 4.168462312402545182e-21 1.584567461330121811e-22 1.326086576913627370e-20 1.345655046407986047e-21 1.871735067225851225e-21 2.843418858962350853e-21 6.866865478903701760e-21 6.982873426987928477e-22 1.060935491622077703e-21 8.786028294001569635e-22 3.638834315968562780e-21 3.044843853857332074e-20 6.160000000000000142e+01 4.196755551692299072e-20 2.564384856930981522e-20 4.330539933879508359e-21 1.572588186715153414e-22 1.325013981665797141e-20 1.339287438032270026e-21 1.865567420573846716e-21 2.836181712867833825e-21 7.734587782138829599e-21 7.158226653163871280e-22 1.043038688062182386e-21 7.949394184719262984e-22 3.608216361400615630e-21 3.066504156779739967e-20 6.170000000000000284e+01 4.348926161495532168e-20 2.564272430509259525e-20 4.507725839543859771e-21 1.560715257915174154e-22 1.323898030578452436e-20 1.333614912765353311e-21 1.859903884437165664e-21 2.828974708626275094e-21 7.814518443699007735e-21 1.083152441303594389e-21 1.027851421881408203e-21 5.210173266129477888e-22 3.577598406832668480e-21 3.070458914666035499e-20 6.180000000000000426e+01 4.203573918916019902e-20 2.564160968258362746e-20 4.605480016695419985e-21 1.548983299148877143e-22 1.322797032997477165e-20 1.327942787438782372e-21 1.854240348300484988e-21 2.821773715458287516e-21 7.502513069109210573e-21 1.851560469231058287e-21 1.016169464791840287e-21 3.149804401679499237e-22 3.546980452264721330e-21 3.066429020815031501e-20 6.190000000000000568e+01 4.174852232403397895e-20 2.564050470304032746e-20 4.623474823264778758e-21 1.537361230945729201e-22 1.321740924082323867e-20 1.322271067199410137e-21 1.848576812163804312e-21 2.814578779501182143e-21 6.681624343745625818e-21 1.452855662037516393e-21 1.000050584412494579e-21 5.936260362984623842e-22 3.516362497696774932e-21 3.044823845672837964e-20 6.200000000000000000e+01 4.438786397205461581e-20 2.563940936770943394e-20 4.650090364376165025e-21 1.525853538634769651e-22 1.320685192106466302e-20 1.316599757282407336e-21 1.842913276027124013e-21 2.807389947326236963e-21 6.141368814276143903e-21 8.725632150026997682e-22 9.841877281401360948e-22 6.108781973404705537e-22 3.485744543128830039e-21 3.030557813027948955e-20 6.210000000000000142e+01 5.072934478941900110e-20 2.563832367782703282e-20 4.728912928493035674e-21 1.514445538631565682e-22 1.319629837893111929e-20 1.310928863013154773e-21 1.837249739890443337e-21 2.800207265943255558e-21 7.450559173231109869e-21 1.243368451741042075e-21 9.945794353815229526e-22 6.936856578920899242e-22 3.455805796464720243e-21 3.061464429851425131e-20 6.220000000000000284e+01 4.250009961673665563e-20 2.563724763461851508e-20 4.813004340243758932e-21 1.503122461705345700e-22 1.318574817819172320e-20 1.305258389809187867e-21 1.831586203753762661e-21 2.793030782805184076e-21 6.419055642642262690e-21 1.374308959759991989e-21 9.853781000709931545e-22 7.873375653410683301e-22 3.426778048352666930e-21 3.039088897979822404e-20 6.230000000000000426e+01 3.728535686080950738e-20 2.563618123929860387e-20 4.830884950996657065e-21 1.491884102727897180e-22 1.317519793072945775e-20 1.299588343182188607e-21 1.825922667617081986e-21 2.785860545812770320e-21 7.822730414431163653e-21 8.117169757387926226e-22 9.616488613586958756e-22 6.802721389914917119e-22 3.397750300240613618e-21 3.068761182422236779e-20 6.240000000000000568e+01 4.014633396953039740e-20 2.563512449307133039e-20 4.782944817143443999e-21 1.480704615545408799e-22 1.316468442829257462e-20 1.293918728740032030e-21 1.820259131480400934e-21 2.778696603319272124e-21 6.949721211855279582e-21 9.920295500511486818e-22 9.622595546108193815e-22 5.201043656260813841e-22 3.368722552128560306e-21 3.046150398188387991e-20 6.250000000000000000e+01 3.907681612858596674e-20 2.563407739713001889e-20 4.726065952039976270e-21 1.469666122606808074e-22 1.315419648002322159e-20 1.288249552188883502e-21 1.814595595343720634e-21 2.771539004135219514e-21 8.109283782128531262e-21 7.347924687859041653e-22 9.557733411015843702e-22 5.884266502835058835e-22 3.339694804016508874e-21 3.072203758798613706e-20 6.260000000000000142e+01 3.893450961605227807e-20 2.563303995265729870e-20 4.600710093703954543e-21 1.458706938930466567e-22 1.314333218586236588e-20 1.282580819335350146e-21 1.808932059207039958e-21 2.764387797533221258e-21 6.596526300690434075e-21 7.330807989222479059e-22 9.580545099564443480e-22 5.062655644399679323e-22 3.310667055904455562e-21 3.032710132456591301e-20 6.270000000000000284e+01 4.065366697631756356e-20 2.563201216082508614e-20 4.466192501836295295e-21 1.447909847867835648e-22 1.313237477162317560e-20 1.276912536088693973e-21 1.803268523070359283e-21 2.757492560411826355e-21 6.765549649383510533e-21 1.473683166835826905e-21 9.455690474029787085e-22 8.501152040003771758e-22 3.281639307792402249e-21 3.036846324765287776e-20 6.280000000000000426e+01 3.821731982152278026e-20 2.563099402279458157e-20 4.263929963148442936e-21 1.437189035682331120e-22 1.312190653842847425e-20 1.271244708463096732e-21 1.797604986933678607e-21 2.750957080841654348e-21 7.078930838750859157e-21 1.035947770621590129e-21 9.383560271265173059e-22 5.264562602674869746e-22 3.252973217910833790e-21 3.037553627344671102e-20 6.290000000000000568e+01 3.717675005349805530e-20 2.562998553971626029e-20 3.994240744542349967e-21 1.426592727419309074e-22 1.311148619335522073e-20 1.265577342579990204e-21 1.791941450796997931e-21 2.744425830839915919e-21 6.599123918154143969e-21 1.072481748054482597e-21 9.266594050239931369e-22 8.114385530252511345e-22 3.225491087679663147e-21 3.022822736440574631e-20 6.300000000000000000e+01 3.947047215351856616e-20 2.562898671272986958e-20 3.743879183803267552e-21 1.416047272871211200e-22 1.310111890237608321e-20 1.259910444670445188e-21 1.786277914660317631e-21 2.737926142100020104e-21 6.057587516772592054e-21 1.214309799777963760e-21 9.205495962323814961e-22 7.096783300393120024e-22 3.198008957448494385e-21 3.007561459605008448e-20 6.310000000000000142e+01 4.477460937344412942e-20 2.562799754296442270e-20 3.733821784859416096e-21 1.405634545595848482e-22 1.309075610290530011e-20 1.254244021077624805e-21 1.780614378523636580e-21 2.731431967643588633e-21 6.300126901483891327e-21 1.489764031100781409e-21 9.075546858562043914e-22 6.731968681472804578e-22 3.170526827217323367e-21 3.012586693480274530e-20 6.320000000000000284e+01 4.323005680645916446e-20 2.562701803153818978e-20 3.743356351014642287e-21 1.395270909229656622e-22 1.308039550524515243e-20 1.248578078259305882e-21 1.774950842386955904e-21 2.724943346896085885e-21 6.576810593802655331e-21 1.038861230108679799e-21 8.970885768962291052e-22 5.750237886059981012e-22 3.143044696986152724e-21 3.015552219375562879e-20 6.330000000000000426e+01 3.960233296672279329e-20 2.562604817955869190e-20 3.768364214099596295e-21 1.385051859432694754e-22 1.307005076804158770e-20 1.242912622790466171e-21 1.769287306250275228e-21 2.718460319625513413e-21 6.474345280933101791e-21 8.199990804469894241e-22 8.871882458254758346e-22 7.225006174033304551e-22 3.115562566754982081e-21 3.012326254455075413e-20 6.340000000000000568e+01 4.256752462259753885e-20 2.562508798812269199e-20 3.820054799417949629e-21 1.374881005158880315e-22 1.305974634697135896e-20 1.237247661365942283e-21 1.763623770113594552e-21 2.711982925945690795e-21 5.605426064561097442e-21 6.685653827277519979e-22 8.652398911645454590e-22 4.541167779708166490e-22 3.088080436523811439e-21 2.993607717452753307e-20 6.350000000000000000e+01 4.094553814105877990e-20 2.562413745831618885e-20 3.859262654583292526e-21 1.364817085558462381e-22 1.304944646767065896e-20 1.231583200803158714e-21 1.757960233976914253e-21 2.705511206319563943e-21 6.266579060140489764e-21 1.059693219509186964e-21 8.684008467329524168e-22 5.463471926729608312e-22 3.060598306292642677e-21 3.007551930484121312e-20 6.360000000000000142e+01 4.062121838052996538e-20 2.562319659121442013e-20 3.684954758997100809e-21 1.354786934802325554e-22 1.303914859002971819e-20 1.225919248044933235e-21 1.752296697840233577e-21 2.699045201562549531e-21 5.832919016108097602e-21 1.105385772356068540e-21 8.315824701118749531e-22 8.305845622472696028e-22 3.034519557301354786e-21 2.996427278100861145e-20 6.370000000000000284e+01 3.888126522162549380e-20 2.562226538788185935e-20 3.496201531855058411e-21 1.344903200126633519e-22 1.302890180770934798e-20 1.220255810162359954e-21 1.746633161703552901e-21 2.692584952845907245e-21 7.042939243417587813e-21 1.003435567498168736e-21 8.244182175773855336e-22 4.327944959982916478e-22 3.008503125191292818e-21 3.017966182288513747e-20 6.380000000000000426e+01 3.628502010393422670e-20 2.562134384937217375e-20 3.496115444022945435e-21 1.335063200124368913e-22 1.301871266684566915e-20 1.214592894357769307e-21 1.740969625566871849e-21 2.686130501700143272e-21 7.375557193690593379e-21 1.351604213114386670e-21 8.311544444069362297e-22 9.024002829193959643e-22 2.982486693081230473e-21 3.027421913468932383e-20 6.390000000000000568e+01 5.641099887329276990e-20 2.562043197672828450e-20 3.674072604918390313e-21 1.325346400122136693e-22 1.300849768268672500e-20 1.208930507967770236e-21 1.735306089430191174e-21 2.679681890018443488e-21 6.069348449339051924e-21 1.254807922015446150e-21 8.025239961311211528e-22 8.261155001766889931e-22 2.956470260971168505e-21 2.998793387863018240e-20 6.400000000000000000e+01 9.749656764605291698e-20 2.561952977098228241e-20 3.848225489731972377e-21 1.315666400119940764e-22 1.299826012311726350e-20 1.203268658466380014e-21 1.729642553293510874e-21 2.673239160060144649e-21 5.856222018107012095e-21 1.593850805614848041e-21 7.927391950490879089e-22 1.033866857519846317e-21 2.930453828861108041e-21 2.998078584723884130e-20 6.410000000000000853e+01 6.009196239231737283e-20 2.561863723315547909e-20 3.970770850799961471e-21 1.306166930810853460e-22 1.298806315829506666e-20 1.197607353468236259e-21 1.723979017156829822e-21 2.666802354454226645e-21 6.029370416040605176e-21 2.010987044219285984e-21 7.924511958176075376e-22 8.741571023778561517e-22 2.904437396751044192e-21 3.004216877349630668e-20 6.420000000000000284e+01 4.118168003933433682e-20 2.561775436425838591e-20 4.087569636911176935e-21 1.296721386254273896e-22 1.297788823564282629e-20 1.191946600731906939e-21 1.718315481020149522e-21 2.660371516202847630e-21 5.806185985771761795e-21 1.143939220710379861e-21 7.720167279743550060e-22 4.409707029543904323e-22 2.878420964640983728e-21 2.994940814775571001e-20 6.429999999999999716e+01 4.176953228364893045e-20 2.561688116529071099e-20 4.302909613084326399e-21 1.287364950608649819e-22 1.296811595783684194e-20 1.186286408163284071e-21 1.712651944883469223e-21 2.653927209364520951e-21 6.413475042910069494e-21 1.289711794331828296e-21 7.695189797316205248e-22 5.152440180669455369e-22 2.853235056331385810e-21 3.010160498874839635e-20 6.440000000000000568e+01 4.129257314707558195e-20 2.561601763724132906e-20 4.622860127729095645e-21 1.278038217933351995e-22 1.295850870970152477e-20 1.180626783819079546e-21 1.706988408746788171e-21 2.647480887556051081e-21 6.198505582126207461e-21 2.053787855690654343e-21 7.782452633686165064e-22 8.954570107477597015e-22 2.828610639621269872e-21 3.014722846855059342e-20 6.450000000000000000e+01 4.159306398868141193e-20 2.561524770485180271e-20 4.910608618069281147e-21 1.268827128822460972e-22 1.294850271094209138e-20 1.175241891938293088e-21 1.701537311630673529e-21 2.641088861086160340e-21 7.454406147860316688e-21 1.270362450190483574e-21 7.725183310981858495e-22 4.098776878512788522e-22 2.803986222911157695e-21 3.041374198548633725e-20 6.460000000000000853e+01 3.953272924977803925e-20 2.561469195518333761e-20 4.711698203664860588e-21 1.259658811988814223e-22 1.293838507399731089e-20 1.170529279841307426e-21 1.696606856543941018e-21 2.635184816352608951e-21 6.003003727185950586e-21 5.109335290576869118e-22 7.680692716840424258e-22 8.414718259455010066e-22 2.779361806201041757e-21 3.003736001039449620e-20 6.470000000000000284e+01 4.076262641703986042e-20 2.561414406612506514e-20 4.475259755448969898e-21 1.250606502568777511e-22 1.292831333180430620e-20 1.165816943741977858e-21 1.691676401457209258e-21 2.629286022817980648e-21 5.946507824845753132e-21 1.019846910741946472e-21 7.533706163202563079e-22 5.657723894750716908e-22 2.754737389490929581e-21 2.998800730081009848e-20 6.479999999999999716e+01 4.117073450532836016e-20 2.561360403818141344e-20 4.402728897087966617e-21 1.241601576458513022e-22 1.291825079358786745e-20 1.161104887000707952e-21 1.686745946370477499e-21 2.623392515904809523e-21 5.746076849409190388e-21 1.928030275067293428e-21 7.348517131664666761e-22 8.028195583492895706e-22 2.730112972780817404e-21 2.997975251138919354e-20 6.490000000000000568e+01 4.019342903540404862e-20 2.561307187184961549e-20 4.493049908238285193e-21 1.232720000102010861e-22 1.290823657918376314e-20 1.156393113032471296e-21 1.681815491283744987e-21 2.617504331322766643e-21 6.011094706332981161e-21 1.471431943432884674e-21 7.403094641549304720e-22 7.185008357010591621e-22 2.705488556070701466e-21 3.000923415345702509e-20 6.500000000000000000e+01 4.062108300671390176e-20 2.561254756761970911e-20 4.582788179612108467e-21 1.223896470688433455e-22 1.289822854874833695e-20 1.151681625307922673e-21 1.676885036197013416e-21 2.611621505071176165e-21 5.532654769388905665e-21 1.252899595768034302e-21 7.398580444600093246e-22 7.114149730810605561e-22 2.681011556883112045e-21 2.991260688326929201e-20 6.510000000000000853e+01 3.882298210094664845e-20 2.561203112597452797e-20 4.670499287657808452e-21 1.215148235392563984e-22 1.288822412007506983e-20 1.146970427354528224e-21 1.671954581110280904e-21 2.605744073441544628e-21 5.785618237842688839e-21 9.188289108774105404e-22 7.337759918792545645e-22 5.179215397473434665e-22 2.657366889353601485e-21 2.994991749484578254e-20 6.520000000000000284e+01 3.917798045366871864e-20 2.561152254738970753e-20 4.773292893947119765e-21 1.206442353037877353e-22 1.287822759828892315e-20 1.142259522757733612e-21 1.667024126023549145e-21 2.599872073020122588e-21 5.664404530764057503e-21 1.441546601500111304e-21 7.259581302692159222e-22 5.551384611533386793e-22 2.633722221824093935e-21 2.995623468251589142e-20 6.529999999999999716e+01 3.866365674567470279e-20 2.561102183233367007e-20 4.693058272970900729e-21 1.197843902534039971e-22 1.286878533775397359e-20 1.137548915162150794e-21 1.662093670936817574e-21 2.594005540690473403e-21 5.851021636169887654e-21 1.495706217301419159e-21 7.168427770121195243e-22 7.799784723581351381e-22 2.610077554294586384e-21 2.997934261068329224e-20 6.540000000000000568e+01 3.672694693037272390e-20 2.561052898126764272e-20 4.424087698752781190e-21 1.189317073264063769e-22 1.285931891655356572e-20 1.132838608272779603e-21 1.657163215850085062e-21 2.588144513636073238e-21 5.623233906173640625e-21 1.234176597974184593e-21 7.215716697021630537e-22 7.342173870604678460e-22 2.586432886765075824e-21 2.987422479391417179e-20 6.550000000000000000e+01 3.998555452108870726e-20 2.561004399464564238e-20 4.168129743188209638e-21 1.180877087470343701e-22 1.284937306717310684e-20 1.128128605856263357e-21 1.652232760763353303e-21 2.582289029342930257e-21 5.882209017904903345e-21 1.210796420552447942e-21 7.054829243962250092e-22 7.812893988523021775e-22 2.562788219235568273e-21 2.987944392736605746e-20 6.560000000000000853e+01 3.857804174152420758e-20 2.560956687291446977e-20 3.992673574759349795e-21 1.172508155429884077e-22 1.283943490202268554e-20 1.123418911742163664e-21 1.647302305676620979e-21 2.576436633912023114e-21 6.764194025453120811e-21 7.914453128994288985e-22 7.094832333071997544e-22 8.811033764734126549e-22 2.539143551706057713e-21 3.002295056798761265e-20 6.570000000000000284e+01 4.098993728748921482e-20 2.560909761651372140e-20 3.841716460011814430e-21 1.164196310768129191e-22 1.282954277194612971e-20 1.118709529824280546e-21 1.642371850589889220e-21 2.570564595150983520e-21 6.457587264264555499e-21 7.750039442819442556e-22 6.922145504734097079e-22 5.368981174567143355e-22 2.515498884176550162e-21 2.991902915541339250e-20 6.579999999999999716e+01 3.953616713200276140e-20 2.560863622587576554e-20 3.761166241252766360e-21 1.155943883582108912e-22 1.281971279311177609e-20 1.114000464061996267e-21 1.637441395503157461e-21 2.564701425015816525e-21 5.038693629796615434e-21 1.509868784738942039e-21 7.028880310398170463e-22 7.877434871919891238e-22 2.492640616713337665e-21 2.966147180490457844e-20 6.590000000000000568e+01 3.760775381268419726e-20 2.560818270142576325e-20 3.737758541635113539e-21 1.147766763370474744e-22 1.281032888774225337e-20 1.109291718481655829e-21 1.632510940416425137e-21 2.558868367883222397e-21 5.203372714362397373e-21 1.103377854072451813e-21 6.774181920110182704e-22 7.901722392167674306e-22 2.470268470729901432e-21 2.966123752778286606e-20 6.600000000000000000e+01 4.106013234227614231e-20 2.560773704358166240e-20 3.721916476313099831e-21 1.139689468682978806e-22 1.280087694955871471e-20 1.104583297177986977e-21 1.627580485329693378e-21 2.553041045125841304e-21 5.467778334144109714e-21 8.114941359589042863e-22 6.516902455001856977e-22 1.009915565592122887e-21 2.447896324746468208e-21 2.969618473995677260e-20 6.610000000000000853e+01 3.775657432630743946e-20 2.560729925275417958e-20 3.775416305976032964e-21 1.131667692390182376e-22 1.279103972600958340e-20 1.099875204315545765e-21 1.622650030242960866e-21 2.547219496099591617e-21 5.629489291238582813e-21 6.158831308139572059e-22 6.738146166361362913e-22 8.695890696675159075e-22 2.425524178763031599e-21 2.971709833716960334e-20 6.620000000000000284e+01 3.681845618147232697e-20 2.560686932934680917e-20 3.843497110160078378e-21 1.123744615465659365e-22 1.278130189504330991e-20 1.095167444130211040e-21 1.617719575156229295e-21 2.541403760481829040e-21 4.343522965589705986e-21 7.213797907851722998e-22 6.866436336263437733e-22 3.682131294193654642e-22 2.403152032779598375e-21 2.949410882027632726e-20 6.629999999999999716e+01 3.554027892458269730e-20 2.560644727375583531e-20 3.982850886308280108e-21 1.115848461618110156e-22 1.277202055994277515e-20 1.090460020930707317e-21 1.612789120069497536e-21 2.535593878274124912e-21 5.194929950214718449e-21 1.010107158614658773e-21 6.695949612612661957e-22 6.050964940536959253e-22 2.380779886796164775e-21 2.965467682094108577e-20 6.640000000000000568e+01 4.061225471357146119e-20 2.560603308637028984e-20 4.197823886155309571e-21 1.108021538539799934e-22 1.276264965815337925e-20 1.085752939100171475e-21 1.607858664982765024e-21 2.529878437309045886e-21 4.805478004204994973e-21 8.501369561569236352e-22 6.430107697574514975e-22 8.023682234924245975e-22 2.358407740812728541e-21 2.961059285852876704e-20 6.650000000000000000e+01 3.881077948410746431e-20 2.560562676757200341e-20 4.405935933751917368e-21 1.100228899598451739e-22 1.275286896684440108e-20 1.081046203097762153e-21 1.602928209896033265e-21 2.524592649233145031e-21 4.944226755731835862e-21 6.882570505413839793e-22 6.400389820201826954e-22 6.674055547711285688e-22 2.336035594829295317e-21 2.964879410146874532e-20 6.660000000000000853e+01 3.696975420954019036e-20 2.560522831773556640e-20 4.346991746797972141e-21 1.092573397204768508e-22 1.274310005045442674e-20 1.076339817460302995e-21 1.597997754809300941e-21 2.519311823166519421e-21 5.292615852361148027e-21 7.113707853329970146e-22 6.506455979370727273e-22 5.381395650201449929e-22 2.314962700152520886e-21 2.969126881669401179e-20 6.670000000000000284e+01 3.994009123143494162e-20 2.560483773722833489e-20 4.275069347789604906e-21 1.084932381026664779e-22 1.273337090455532353e-20 1.071633786803977621e-21 1.593067299722569182e-21 2.514035990377824721e-21 4.994858235047593538e-21 7.916764118301712929e-22 6.392488834579179207e-22 6.229882635134419685e-22 2.293892152313318257e-21 2.962558241210568705e-20 6.679999999999999716e+01 3.660408293575454096e-20 2.560445502641043972e-20 4.276599424605201931e-21 1.077408571501563515e-22 1.272374188311491366e-20 1.066928115826062960e-21 1.588136844635837423e-21 2.508765182369052035e-21 6.440579246425306532e-21 8.115535068681972206e-22 6.359202913840183184e-22 6.638665471109439804e-22 2.272821604474115629e-21 2.989795250513759945e-20 6.690000000000000568e+01 3.528786216547575261e-20 2.560408018563475339e-20 4.354164587224377638e-21 1.069885904833650412e-22 1.271451737866889532e-20 1.062222809306707730e-21 1.583206389549105099e-21 2.503499430877356792e-21 5.020079552494160248e-21 8.782282106269853935e-22 6.145036503331970381e-22 7.556215220095712763e-22 2.251751056634909991e-21 2.963261521111676102e-20 6.700000000000000000e+01 3.599171169791528066e-20 2.560371321524695926e-20 4.432720925427067902e-21 1.062476381022885195e-22 1.270520632275989033e-20 1.057517872110765269e-21 1.578275934462373340e-21 2.498233451327726068e-21 5.359622509032161349e-21 1.009937370372872622e-21 6.189473971669255382e-22 5.846374402413350038e-22 2.230680508795706986e-21 2.969729836380766200e-20 6.710000000000000853e+01 3.734687840021299156e-20 2.560335411558545226e-20 4.422602557902682491e-21 1.055066857212157358e-22 1.269553010736286133e-20 1.052813309189663977e-21 1.573345479375641016e-21 2.492949857399257970e-21 4.667861470419980463e-21 1.175266841006747982e-21 6.343382032604612540e-22 7.318628630950803116e-22 2.209609960956501348e-21 2.958154779274676771e-20 6.720000000000000284e+01 3.680090866525749832e-20 2.560300288698141107e-20 4.407294091514161129e-21 1.047792796276632778e-22 1.268595777906862425e-20 1.048109125583336071e-21 1.568415024288909257e-21 2.487676356665838460e-21 4.874537906955303649e-21 8.577269010952914370e-22 6.462987135931464158e-22 8.809503393661076521e-22 2.188539413117298719e-21 2.959915183119748535e-20 6.729999999999999716e+01 3.986694412518269204e-20 2.560265952975877712e-20 4.288780041539238323e-21 1.040532132768372301e-22 1.267682979076700463e-20 1.043405326422193732e-21 1.563484569202177497e-21 2.482431034044149422e-21 5.365667640674625048e-21 8.960929965714688272e-22 6.385175235337047732e-22 4.897845728824916070e-22 2.167829830684756573e-21 2.965196020481675288e-20 6.740000000000000568e+01 3.852692127134439413e-20 2.560232404423424852e-20 4.065623936381619949e-21 1.033374339688441873e-22 1.266770328335864655e-20 1.038701916929157160e-21 1.558554114115444986e-21 2.477190929831732531e-21 5.741639005423636453e-21 9.056528155923393561e-22 6.308898927002884175e-22 6.485491879154412468e-22 2.148003620294205708e-21 2.968759556127567041e-20 6.750000000000000000e+01 4.083624910408924986e-20 2.560199643071726504e-20 3.869347104993328131e-21 1.026242264215624579e-22 1.265857757609420161e-20 1.033998902421744698e-21 1.553623659028713415e-21 2.471956077214868949e-21 5.067865180342943483e-21 7.843003316678336063e-22 6.247760351402973558e-22 6.644892523276443922e-22 2.128177409903657853e-21 2.952858052693969362e-20 6.760000000000000853e+01 3.862040128718526577e-20 2.560186050715975878e-20 3.822957015437419641e-21 1.019187169874887063e-22 1.264939068935462683e-20 1.029922026030534817e-21 1.549204745229970578e-21 2.466726509628144876e-21 4.760525968775883782e-21 1.260831227357571420e-21 6.004456440443828323e-22 6.558086487146842006e-22 2.108351199513106988e-21 2.948086355623490931e-20 6.770000000000000284e+01 4.081193632614938070e-20 2.560177672116353754e-20 3.805437465294609395e-21 1.012168301949285727e-22 1.263981986444245688e-20 1.026000284298281042e-21 1.544912482096901420e-21 2.461502260756385743e-21 5.385495355673013200e-21 1.409893761157708883e-21 5.982552068280284882e-22 6.639050019819645770e-22 2.088524989122558756e-21 2.958644989844752544e-20 6.779999999999999716e+01 3.851731454906476931e-20 2.560169942482484636e-20 3.863392143409697133e-21 1.005230985976916125e-22 1.263031051184638253e-20 1.022078733954082820e-21 1.540620218963832075e-21 2.456283364536583657e-21 4.539201711253681146e-21 1.004011171082523127e-21 6.009052423568305430e-22 7.060553527526871502e-22 2.068698778732010901e-21 2.942975791425921320e-20 6.790000000000000568e+01 3.701901178374774604e-20 2.560162861820247122e-20 3.991379312444212419e-21 9.983577465392648378e-23 1.262127927976684960e-20 1.018157377209398237e-21 1.536327955830762165e-21 2.451069855159851162e-21 4.880772464943642133e-21 9.701208723523611754e-22 6.005115019402633521e-22 9.991057572419374770e-22 2.048872568341460036e-21 2.950263760358376702e-20 6.800000000000000000e+01 3.975818013944739806e-20 2.560156430135025392e-20 4.108040941426112123e-21 9.915168075711018030e-23 1.261224860022678794e-20 1.014236216309779042e-21 1.532035692697692819e-21 2.445861767073381776e-21 4.712774805319604520e-21 7.203921124122326894e-22 6.141680813143586021e-22 9.051228458023703912e-22 2.029046357950912181e-21 2.947533679526364496e-20 6.810000000000000853e+01 3.644189991901205956e-20 2.560150647431711909e-20 4.130953570793692148e-21 9.847186855043768175e-23 1.260321847441393812e-20 1.010315253535522340e-21 1.527743429564622909e-21 2.440659134982418802e-21 5.399619128808151711e-21 9.676411791509167163e-22 5.870191096661871074e-22 8.489453928355526667e-22 2.009794861762446262e-21 2.959495005878220157e-20 6.820000000000000284e+01 3.636839793259136947e-20 2.560145513714702608e-20 4.142675667612571696e-21 9.779730233131861632e-23 1.259417641863889199e-20 1.006394491202347675e-21 1.523451166431553563e-21 2.435461993852244455e-21 4.787815438996652087e-21 1.155653683119881236e-21 6.018214073539415258e-22 5.301255539555076765e-22 1.991135275047286239e-21 2.948475662372837289e-20 6.829999999999999716e+01 3.739421496673925764e-20 2.560141028987902613e-20 4.135763568636135690e-21 9.713497674982691217e-23 1.258466564294104126e-20 1.002473931662082018e-21 1.519158903298484218e-21 2.430270378910170865e-21 5.105669488261599529e-21 1.090183357827150660e-21 6.224930988977129246e-22 8.346023820524587415e-22 1.972475688332126215e-21 2.953591179156087065e-20 6.840000000000000568e+01 3.577133435836425328e-20 2.560137193254722325e-20 4.117077941571106598e-21 9.647404651717255262e-23 1.257515536774382407e-20 9.985535773033644971e-22 1.514866640165414308e-21 2.425385147601413706e-21 4.609151390395945515e-21 9.802191787859643354e-22 6.067271524739343926e-22 6.779859746897440058e-22 1.953816101616963559e-21 2.943720647454483185e-20 6.850000000000000000e+01 3.819834548404091377e-20 2.560134006518078324e-20 4.105390972269167007e-21 9.582102326126662135e-23 1.256621434201604737e-20 9.946334305523697480e-22 1.510574377032344962e-21 2.420582983510215262e-21 5.223132713355843989e-21 1.417990277016067830e-21 6.102482789640210026e-22 4.959172272384071490e-22 1.935156514901803159e-21 2.954635518432762231e-20 6.860000000000000853e+01 3.975439328007961922e-20 2.560131468780394874e-20 4.068739119623050884e-21 9.516800000536092518e-23 1.255727957990019759e-20 9.907134938735410498e-22 1.506282113899275052e-21 2.415785207086019766e-21 6.082771662521125257e-21 6.109438571166905750e-22 5.876321129565190599e-22 8.847295585120359478e-22 1.916496928186640502e-21 2.968058419617851514e-20 6.870000000000000284e+01 4.093449633540747694e-20 2.560129580043600914e-20 4.034396360860048136e-21 9.452427907503853335e-23 1.254830579069110232e-20 9.867937697703494101e-22 1.501989850766205707e-21 2.411018433481746570e-21 5.397259309392467692e-21 7.242281976633666537e-22 5.814831510720899840e-22 1.006539945223359759e-21 1.897837341471480479e-21 2.954356622824214436e-20 6.879999999999999716e+01 3.707653362145087250e-20 2.560128340309135175e-20 3.945857680100247719e-21 9.388055814471655294e-23 1.253932954466578866e-20 9.828742607860635614e-22 1.497697587633136361e-21 2.406258472090062722e-21 4.749385296079254706e-21 1.565142348079985652e-21 5.947296279288655066e-22 5.892007577916432597e-22 1.879177754756320455e-21 2.943597840355595679e-20 6.890000000000000568e+01 3.824180799544646206e-20 2.560127749577937751e-20 3.798052454887976041e-21 9.324724074583640748e-23 1.253000930249971060e-20 9.789549695045413978e-22 1.493405324500066451e-21 2.401503375523194861e-21 5.021011054988465485e-21 1.475298886976914172e-21 5.816371239766737979e-22 7.357359659329990729e-22 1.861181426747998304e-21 2.945414970885913847e-20 6.900000000000000000e+01 4.064155451720846939e-20 2.560127807850458827e-20 3.645894070935204666e-21 9.261575926426967706e-23 1.252064276585920142e-20 9.750358985510432291e-22 1.489113061366997105e-21 2.396753172736206095e-21 5.300821322356219412e-21 1.098735809998589123e-21 5.710479371645818819e-22 7.150011907702113897e-22 1.843618510576252622e-21 2.946095404083422238e-20 6.910000000000000853e+01 3.810239005926973216e-20 2.560128515126654771e-20 3.466391557677019317e-21 9.199264516621748983e-23 1.251166691322124467e-20 9.711170505930563195e-22 1.484820798233927195e-21 2.392007892884241831e-21 4.858078195732673620e-21 8.379052048309812567e-22 5.768249442154314696e-22 9.032230863646656515e-22 1.826055594404504307e-21 2.935383166116818928e-20 6.920000000000000284e+01 3.909438079846989678e-20 2.560129871405987223e-20 3.292576852149992647e-21 9.137329032742526072e-23 1.250278303892389592e-20 9.671984283411491430e-22 1.480528535100857850e-21 2.387267565323926461e-21 4.311788401049560985e-21 5.079927518927670311e-22 5.811462411468342313e-22 1.352185013484931545e-21 1.808492678232759001e-21 2.925249274548788759e-20 6.929999999999999716e+01 4.257708159059529651e-20 2.560131876687424909e-20 3.295851339549934373e-21 9.076018349100293981e-23 1.249393294549744998e-20 9.632800345498371111e-22 1.476236271967788504e-21 2.382532219614755513e-21 4.160961649952102577e-21 4.021710089653868251e-22 5.976084849507518944e-22 8.819505808143461047e-22 1.790929762061013320e-21 2.920613195477787649e-20 6.940000000000000568e+01 4.283437742876899403e-20 2.560134530969442432e-20 3.469794746397438032e-21 9.015284404138214536e-23 1.248509640674135490e-20 9.593618720184765133e-22 1.471944008834718594e-21 2.377801885520505500e-21 4.326793128310592341e-21 1.525920376878955499e-21 5.959587913124371377e-22 5.657873186697950022e-22 1.773366845889265005e-21 2.927396005250137701e-20 6.950000000000000000e+01 3.968185765214199545e-20 2.560137834250020876e-20 3.653069590007022606e-21 8.954862385781831533e-23 1.247626033765854685e-20 9.554439435921772645e-22 1.467651745701649437e-21 2.373076593010643757e-21 4.327537616187854240e-21 1.121806474994798986e-21 5.561587386632833092e-22 5.397532968766051078e-22 1.755803929717519323e-21 2.927129095064302126e-20 6.960000000000000853e+01 3.882808168743874701e-20 2.560141786526648707e-20 3.890740111424944318e-21 8.895045872012680558e-23 1.246742473924764610e-20 9.515262521627352132e-22 1.463359482568579339e-21 2.368356372261743547e-21 5.054180468192889306e-21 1.486266435632820751e-21 5.674007505418407507e-22 9.474236921047608584e-22 1.738241013545771384e-21 2.943918727542184411e-20 6.970000000000000284e+01 4.377429078023323481e-20 2.560146387796320874e-20 4.134984947087089962e-21 8.835419178527755498e-23 1.245861391547642373e-20 9.476088006695941662e-22 1.459067219435510181e-21 2.363624759021069150e-21 3.938934537134762768e-21 1.923297207659248099e-21 5.684528015307704026e-22 4.612962936771553190e-22 1.721332858872431450e-21 2.931014635007442865e-20 6.979999999999999716e+01 4.142140142255598261e-20 2.560151638055536095e-20 4.144746881542383843e-21 8.776789041534072870e-23 1.244982269883445582e-20 9.436915921008233356e-22 1.454774956302440835e-21 2.358886244905444716e-21 4.027261637064398735e-21 2.241197665099377010e-21 5.623096572750697291e-22 6.214440991914635099e-22 1.704816678595641396e-21 2.934355487216762239e-20 6.990000000000000568e+01 4.244827376892224734e-20 2.560157537300303784e-20 3.942127106647674736e-21 8.718158904540547759e-23 1.244105199622160141e-20 9.397746294941250665e-22 1.450482693169370926e-21 2.354166771197879513e-21 4.373873621117996517e-21 1.842281981936207738e-21 5.471423298453204227e-22 5.896255753532314649e-22 1.688300498318849274e-21 2.933120753849112667e-20 7.000000000000000000e+01 4.668840648688465267e-20 2.560164085526136524e-20 3.785901931184662930e-21 8.660492727696592819e-23 1.243230698371019406e-20 9.358579159378677674e-22 1.446190430036301580e-21 2.349467024084557097e-21 3.892528734099365257e-21 1.210257073407131718e-21 5.567781481155410204e-22 5.977134736083893810e-22 1.671784318042059596e-21 2.920466992792952650e-20 7.010000000000000853e+01 4.721403253118412123e-20 2.560171282728054883e-20 3.795874205716367781e-21 8.602856364053241239e-23 1.242356254573750725e-20 9.319414545721378368e-22 1.441898166903231670e-21 2.344772502426814554e-21 4.359739550662485276e-21 1.348130360484849765e-21 5.731970409809427910e-22 7.360683576526795447e-22 1.655268137765267286e-21 2.927608682364641798e-20 7.020000000000000284e+01 4.649994948530989039e-20 2.560179128900585610e-20 3.839496683976261807e-21 8.546117647468842230e-23 1.241481921292710762e-20 9.280252485898273245e-22 1.437605903770162324e-21 2.340083237673554282e-21 4.321287136662156393e-21 1.077623947341698035e-21 5.644244812938462567e-22 1.004966592268021725e-21 1.638751957488477420e-21 2.926740951236447718e-20 7.029999999999999716e+01 3.952124688488347554e-20 2.560187624037761630e-20 4.033223215590997298e-21 8.489647059226776041e-23 1.240608827102514373e-20 9.241093012377398365e-22 1.433313640637092979e-21 2.335399261490902883e-21 3.963415041833903463e-21 6.607985354572313162e-22 5.622558872760339955e-22 9.554874810264791781e-22 1.622235777211687743e-21 2.922344429155402999e-20 7.040000000000000568e+01 3.832320592197478309e-20 2.560196768133123256e-20 4.366798937232184310e-21 8.433581900849149623e-23 1.239738786956129936e-20 9.201936158177314230e-22 1.429021377504023069e-21 2.331023551040799524e-21 4.525341122956225371e-21 9.967015872037989643e-22 5.747720966636056729e-22 9.863443166685980682e-22 1.605719596934895432e-21 2.935827395552194398e-20 7.050000000000000000e+01 3.961046630826498976e-20 2.560206561179716977e-20 4.636126891003131043e-21 8.377835294507783094e-23 1.238869616330067269e-20 9.162781956878777972e-22 1.424729114370953723e-21 2.326760539387313100e-21 4.770262547443819981e-21 8.621629252726415342e-22 5.366121115706007125e-22 1.531885854847640699e-21 1.589746659220503299e-21 2.945148777091679277e-20 7.060000000000000853e+01 4.061666404446259025e-20 2.560217003170096366e-20 4.495595953121316391e-21 8.322405430248073245e-23 1.238003822166540323e-20 9.123630442636686378e-22 1.420436851237883813e-21 2.322502003357172983e-21 4.855809325389717800e-21 1.100151513683914974e-21 5.363113296182776752e-22 9.816438700712387154e-22 1.574211464434919183e-21 2.942305970611716872e-20 7.070000000000000284e+01 4.158118533035709921e-20 2.560228094096319669e-20 4.293606947354427150e-21 8.267563801282491659e-23 1.237138146687285225e-20 9.084481650192380018e-22 1.416144588104814467e-21 2.318247967615046637e-21 4.650627149507167829e-21 1.094589051284576977e-21 5.570994691180064703e-22 7.654513652393049948e-22 1.558676269649337325e-21 2.934837282133733297e-20 7.079999999999999716e+01 3.839500064617361490e-20 2.560255672285788928e-20 4.154983698771902817e-21 8.212891480192049504e-23 1.236272536479022519e-20 9.050952189470581728e-22 1.412336529740840389e-21 2.313998456980810791e-21 4.698085615243840864e-21 9.344040313081823439e-22 5.403838377459192193e-22 4.704022896142576550e-22 1.543141074863755466e-21 2.931905014321899244e-20 7.090000000000000568e+01 3.892885212405646787e-20 2.560286135637086076e-20 4.081326995623585748e-21 8.159259193190404629e-23 1.235407109410698012e-20 9.018252113604813349e-22 1.408599851791356996e-21 2.309753496430498982e-21 3.985423256130898015e-21 6.589849638940642134e-22 5.450318085130262076e-22 7.653865848075145646e-22 1.527605880078171350e-21 2.919692087928345608e-20 7.100000000000000000e+01 3.891507984250893251e-20 2.560317142508757074e-20 4.048049846644810863e-21 8.105626906189016012e-23 1.234545463149069374e-20 8.985553359069951383e-22 1.404863173841874167e-21 2.305513111097250599e-21 4.038854094376200911e-21 9.014892581778145381e-22 5.431041453106722754e-22 7.040641064210085211e-22 1.512070685292589492e-21 2.919973286023060791e-20 7.110000000000000853e+01 4.012961522147822958e-20 2.560348692881054217e-20 4.243132799317371220e-21 8.052810762685370624e-23 1.233684410308954954e-20 8.952855940343782983e-22 1.401126495892390773e-21 2.301277326272259184e-21 3.983717275345127739e-21 8.661309395739472652e-22 5.433444594576611248e-22 6.095895293764815173e-22 1.496535490507005376e-21 2.921188323877677070e-20 7.120000000000000284e+01 3.640167067975333072e-20 2.560380786733887349e-20 4.476185336516705758e-21 8.000075336670696923e-23 1.232823428337952153e-20 8.920159872115799011e-22 1.397389817942907944e-21 2.297022910790360127e-21 4.179417947787524226e-21 1.593854488167218494e-21 5.532521600281687175e-22 8.371950311828230275e-22 1.481000295721423517e-21 2.930556141893191444e-20 7.129999999999999716e+01 3.813470862120493775e-20 2.560413424046817839e-20 4.459047937060221558e-21 7.947985714627863638e-23 1.231962539580612014e-20 8.887465169291017692e-22 1.393653139993425115e-21 2.292767596367108805e-21 4.060522092132489098e-21 1.134569386257624472e-21 5.600988886433829901e-22 5.486528619165271831e-22 1.465823302524354201e-21 2.925340432123445505e-20 7.140000000000000568e+01 4.100841804568697920e-20 2.560446604799064902e-20 4.205308836237869293e-21 7.896200000336619572e-23 1.231104395394654939e-20 8.854771846993983170e-22 1.389916462043941722e-21 2.288536448948458173e-21 4.198973823553682223e-21 1.142384334283872913e-21 5.400996201604403729e-22 6.462273193096759105e-22 1.451210221637649200e-21 2.923262613129302302e-20 7.150000000000000000e+01 3.857667721545661979e-20 2.560480328969500787e-20 3.986475954103884749e-21 7.844828444775610106e-23 1.230247684921482762e-20 8.822079920572794164e-22 1.386179784094458893e-21 2.284319208945929621e-21 4.102963101435826392e-21 9.647084177725985602e-22 5.359999714687508252e-22 4.862883066148183362e-22 1.436597140750946267e-21 2.917405498989314106e-20 7.160000000000000853e+01 3.987461854504095889e-20 2.560514596536653481e-20 3.915146978752404317e-21 7.793984000325816327e-23 1.229393290547377083e-20 8.789389405603221020e-22 1.382443106144975500e-21 2.280106698020546927e-21 4.304348078712155675e-21 7.882756033423995796e-22 5.650643772444744335e-22 5.978242967360170369e-22 1.421984059864241266e-21 2.918610674532446147e-20 7.170000000000000284e+01 3.748529384318544229e-20 2.560549407478707313e-20 3.867335335530230169e-21 7.743274666987249425e-23 1.228540751686379328e-20 8.756700317892976988e-22 1.378706428195492482e-21 2.275898942431766414e-21 4.514552648843674833e-21 1.237602839847442716e-21 5.616670670544938032e-22 4.879909772967516841e-22 1.407370978977538334e-21 2.922035819564734118e-20 7.179999999999999716e+01 3.786910607460800098e-20 2.560584761773499644e-20 3.798620937489552446e-21 7.693141333648745821e-23 1.227688341329041248e-20 8.724012673485972568e-22 1.374969750246009653e-21 2.271695968603847210e-21 3.846173130502687509e-21 8.391748464122819411e-22 5.400649663080314416e-22 4.999358248856525630e-22 1.392757898090835402e-21 2.909652228577497408e-20 7.190000000000000568e+01 4.005737848109832490e-20 2.560620659398525683e-20 3.708048042127385554e-21 7.643008000310355065e-23 1.226835968774979325e-20 8.691326488666784273e-22 1.371233072296526260e-21 2.267497803126823990e-21 3.940072249459563746e-21 1.153522337062478328e-21 5.388508428525907591e-22 6.419145635561403971e-22 1.378144817204130588e-21 2.910635027235090671e-20 7.200000000000000000e+01 3.475836986051932481e-20 2.560657100330933970e-20 3.611009505090416277e-21 7.593748672871701983e-23 1.225984632131621485e-20 8.658641779965157241e-22 1.367496394347043431e-21 2.263304472757486118e-21 4.265854407340614402e-21 1.290377958547971380e-21 5.428807487217972777e-22 8.757219096614089315e-22 1.363531736317427656e-21 2.914740463719066002e-20 7.210000000000000853e+01 3.732845644729107140e-20 2.560694084547528784e-20 3.429508562220394924e-21 7.544545133043828071e-23 1.225136277547660805e-20 8.625958564160596244e-22 1.363759716397560038e-21 2.259116004420351897e-21 4.621431683288056927e-21 1.216820276551593732e-21 5.312709346297372864e-22 8.905659981602090484e-22 1.349031564642406182e-21 2.917223976258363860e-20 7.220000000000000284e+01 3.788907795165573029e-20 2.560731612024771651e-20 3.238105640813025823e-21 7.496088106022478219e-23 1.224292219320132062e-20 8.593276858287127855e-22 1.360023038448077209e-21 2.254932425208652972e-21 3.797688882396543804e-21 1.312537320747329071e-21 5.397956915303150598e-22 8.254851754275148508e-22 1.335297177764259735e-21 2.902909877600502959e-20 7.229999999999999716e+01 3.639796062840788947e-20 2.560769682738777729e-20 3.371083939591869043e-21 7.447982379145550410e-23 1.223494166794366536e-20 8.560596679638100223e-22 1.356286360498594380e-21 2.250753762385313850e-21 3.618790878214161897e-21 1.286286830367290978e-21 5.325557163580536197e-22 4.337414148629260203e-22 1.321562790886113287e-21 2.900731612172120791e-20 7.240000000000000568e+01 3.876508895208350044e-20 2.560808296665318820e-20 3.828707052417913499e-21 7.400093392356728123e-23 1.222696195494243972e-20 8.527918045771120148e-22 1.352549682549110986e-21 2.246629256426518865e-21 3.740943639004968413e-21 1.696180281019236037e-21 5.248140895300088009e-22 4.325350471014771254e-22 1.307828404007964771e-21 2.909614393031160225e-20 7.250000000000000000e+01 3.797154096805275815e-20 2.560847453779822163e-20 4.233752121664700387e-21 7.352516299841183472e-23 1.221856468456953665e-20 8.495240974513131222e-22 1.348813004599628157e-21 2.242763891269112582e-21 3.428220126543347898e-21 1.038998851603796954e-21 5.211330663191388843e-22 9.009620502175938492e-22 1.294094017129818324e-21 2.908914806470718212e-20 7.260000000000000853e+01 3.606802452824896683e-20 2.560887154057371643e-20 4.092427983916519390e-21 7.305066666943863698e-23 1.221012646848067169e-20 8.462565483965544621e-22 1.345076326650144764e-21 2.238900071791464034e-21 3.642898718584347129e-21 1.085572972453405778e-21 5.302862882583848982e-22 8.284508063588308168e-22 1.280359630251669807e-21 2.909035719932402784e-20 7.270000000000000284e+01 3.606425424506764048e-20 2.560927397472705378e-20 3.893285328630824201e-21 7.258400000272801255e-23 1.220171730691386349e-20 8.429891592509562690e-22 1.341339648700661935e-21 2.235061843135602544e-21 3.642837011739958431e-21 1.024952253040469147e-21 5.423686696392386750e-22 7.135351293985561341e-22 1.266625243373523360e-21 2.905363155154708537e-20 7.279999999999999716e+01 3.688704690240909001e-20 2.560968184000219332e-20 3.719069966819741071e-21 7.211733333601799938e-23 1.219331837070491949e-20 8.397219318811557056e-22 1.337602970751179106e-21 2.231235411957300379e-21 3.951014599243904675e-21 8.180328140590450848e-22 5.423768632786047483e-22 4.783900999941652350e-22 1.252890856495376912e-21 2.905537273127624185e-20 7.290000000000000568e+01 3.587212628190356966e-20 2.561009513613964008e-20 3.565879791404261953e-21 7.165842795024034090e-23 1.218494327620916727e-20 8.364548681828608507e-22 1.333866292801695712e-21 2.227413283497561273e-21 3.644469683245847449e-21 1.028960964720180458e-21 5.340518046108185802e-22 6.286882972266260472e-22 1.239156469617228584e-21 2.900116487510404365e-20 7.300000000000000000e+01 3.512557981212016142e-20 2.561051386287647753e-20 3.435511958951124206e-21 7.120078602880129709e-23 1.217658547197514508e-20 8.331879700814194499e-22 1.330129614852212695e-21 2.223595479944159326e-21 4.072989351508299378e-21 4.749930376647127043e-22 5.394979683757214324e-22 5.329600817151904758e-22 1.226096219105539427e-21 2.902200142963220874e-20 7.310000000000000853e+01 3.574669023557031496e-20 2.561093801994633451e-20 3.446029963410110380e-21 7.074712664011375158e-23 1.216839664664749129e-20 8.299212395323948138e-22 1.326392936902729490e-21 2.219782023612315173e-21 3.438476032081286840e-21 3.450036446136082927e-22 5.198710770745402219e-22 9.170751881697271416e-22 1.213234168523381118e-21 2.894427483145448743e-20 7.320000000000000284e+01 3.478825070206535173e-20 2.561136760707941833e-20 3.475694328457469294e-21 7.029647161823936372e-23 1.216049531146823025e-20 8.266546785221620287e-22 1.322656258953246473e-21 2.215972936945362912e-21 3.681709804575426908e-21 8.647484318979275107e-22 5.040245582709036111e-22 9.719549112135156410e-22 1.200372117941224689e-21 2.898604682325646004e-20 7.329999999999999716e+01 3.461888481234314043e-20 2.561180262400249070e-20 3.506417930160294968e-21 6.984884848732729453e-23 1.215252023874050589e-20 8.233882890685131014e-22 1.318919581003763644e-21 2.212168242515408753e-21 3.677083704892770961e-21 1.052148372723596257e-21 5.276385751314510061e-22 7.437871121890146014e-22 1.187510067359068260e-21 2.898497879075788053e-20 7.340000000000000568e+01 3.561122983373008816e-20 2.561224307043887371e-20 3.538429012076323222e-21 6.940902164746149159e-23 1.214420552176374853e-20 8.201220732212786543e-22 1.315182903054280251e-21 2.208367963023994189e-21 3.385124400206819769e-21 5.989194214028190586e-22 5.227567053401129197e-22 4.834750942514626502e-22 1.174648016776909951e-21 2.893056874768829811e-20 7.350000000000000000e+01 4.007481413567834033e-20 2.561268894610847396e-20 3.558377235796413711e-21 6.896919480759587674e-23 1.213589112233219586e-20 8.168560330629663602e-22 1.311446225104797421e-21 2.204572121302762548e-21 3.424354690145313746e-21 8.630857360439899974e-22 5.278588406258204352e-22 6.935106041936035727e-22 1.161785966194753522e-21 2.894450271606128818e-20 7.360000000000000853e+01 3.447735406870701782e-20 2.561314025072774943e-20 3.501598516704491876e-21 6.853440692877058633e-23 1.212761325785966752e-20 8.135901707094085924e-22 1.307709547155314028e-21 2.200780740314118395e-21 3.532597001717103123e-21 8.748672838620727231e-22 5.385304796478186223e-22 6.843263714215367687e-22 1.148923915612595401e-21 2.894678381496344118e-20 7.370000000000000284e+01 3.715156864819493669e-20 2.561359698400973353e-20 3.432305099056146682e-21 6.809977489410132392e-23 1.211933645206680322e-20 8.103244883104331149e-22 1.303972869205831199e-21 2.196993843151896722e-21 3.993295064704917924e-21 4.338644287203177836e-22 5.318978348717884524e-22 1.082031199278841202e-21 1.136061865030438973e-21 2.899625428460163883e-20 7.379999999999999716e+01 4.042342899055967065e-20 2.561405914566401410e-20 3.359607841359280113e-21 6.767093103677288041e-23 1.211140818411059833e-20 8.070589880505439286e-22 1.300236191256348370e-21 2.193189139555585821e-21 3.344416280145090968e-21 9.089357636942567115e-22 5.186333596120702144e-22 6.558284802482863867e-22 1.123447921591586434e-21 2.889952121670208058e-20 7.390000000000000568e+01 3.762827870524540884e-20 2.561452673539677547e-20 3.284434094586858702e-21 6.724506896777127002e-23 1.210358434479993820e-20 8.037936721496203615e-22 1.296499513306864977e-21 2.189382213284809465e-21 3.917267475643253797e-21 9.541681523862926704e-22 5.253721954872605580e-22 8.319277991462918033e-22 1.111360625378466698e-21 2.896501020899965000e-20 7.400000000000000000e+01 3.901785150272218050e-20 2.561499975291074133e-20 3.215350477227393088e-21 6.682155172635675992e-23 1.209552942722362311e-20 8.005285428636365652e-22 1.292762835357382148e-21 2.185596024557642565e-21 3.356068659746992418e-21 1.122423677037957164e-21 5.209145267427093420e-22 8.302843663580654174e-22 1.099273329165348842e-21 2.888864928725000607e-20 7.410000000000000853e+01 3.770052047733805295e-20 2.561554039437581342e-20 3.177504661065533498e-21 6.640258620908071471e-23 1.208729420032236300e-20 7.974934852459526365e-22 1.289234876298886055e-21 2.181827185288119222e-21 4.110214425602948918e-21 1.640407166659359576e-21 5.022182837210543007e-22 6.441296037655728315e-22 1.087186032952229106e-21 2.899744689046589909e-20 7.420000000000000284e+01 3.767339167867018396e-20 2.561616782227318894e-20 3.151166836154301078e-21 6.598375965880237757e-23 1.207921217821141408e-20 7.947613777378918952e-22 1.285981869280146457e-21 2.178062947060981303e-21 3.058218591396871449e-21 1.597601399449120881e-21 5.075063010885931564e-22 6.376973581609691959e-22 1.075098736739111251e-21 2.885799835907246825e-20 7.429999999999999716e+01 3.944843820979790806e-20 2.561679987488619751e-20 3.180685820238957360e-21 6.557174249138687434e-23 1.207142784066501148e-20 7.920293606655081080e-22 1.282728862261406859e-21 2.174303333772737235e-21 2.940490374776375689e-21 8.813921317522161242e-22 5.294754561305716294e-22 6.986497568741966206e-22 1.063011440525993396e-21 2.881636603582252486e-20 7.440000000000000568e+01 3.793487904543537341e-20 2.561743655187252013e-20 3.280171133373024627e-21 6.515972532397160622e-23 1.206359852351508142e-20 7.892974349678835871e-22 1.279475855242666885e-21 2.170548369455997375e-21 3.350079030974118397e-21 1.882202610312651288e-21 5.174672941727259567e-22 9.880117110342301927e-22 1.050924144312873660e-21 2.892460301694303390e-20 7.450000000000000000e+01 3.890407873659518214e-20 2.561807785288738224e-20 3.397195002035371456e-21 6.475364102769223524e-23 1.205543917273673012e-20 7.865656015971164708e-22 1.276222848223927475e-21 2.166798078280143953e-21 3.285313068226538236e-21 2.202905917908779960e-21 4.992492171920221368e-22 6.515655978133157435e-22 1.038836848099755805e-21 2.893969840032072103e-20 7.460000000000000853e+01 4.172417953364741554e-20 2.561872377758352363e-20 3.471731353095101608e-21 6.435022222424140903e-23 1.204728091511601212e-20 7.838338615185443490e-22 1.272969841205187501e-21 2.163363906360873652e-21 4.261862390168178456e-21 2.799964738204089836e-21 5.243286663618625352e-22 1.704308114450739136e-21 1.026749551886636257e-21 2.916616380360980215e-20 7.470000000000000284e+01 4.033607876352441368e-20 2.561937432561122852e-20 3.540641563823177856e-21 6.394919149134988043e-23 1.203951569323317106e-20 7.811022157109771996e-22 1.269716834186447903e-21 2.159947162682336289e-21 3.126749704585900650e-21 2.490416344137000877e-21 5.144150908252269431e-22 1.096457158133155797e-21 1.015224223408944710e-21 2.896906010027429561e-20 7.479999999999999716e+01 3.964107109418123719e-20 2.562002949661829548e-20 3.638791026733882598e-21 6.355259574663807917e-23 1.203180526168707353e-20 7.783706651669301359e-22 1.266463827167708494e-21 2.156534373832980729e-21 3.261865033254917536e-21 2.147361573184655441e-21 4.956865153345748343e-22 7.771084815097053519e-22 1.003867029580997001e-21 2.895451255508573268e-20 7.490000000000000568e+01 3.756050918889419880e-20 2.562068929025008257e-20 3.768116900815321929e-21 6.315600000192695968e-23 1.202380988148608529e-20 7.756392108928648066e-22 1.263210820148968331e-21 2.153125558618487472e-21 3.534272668888665171e-21 1.961832984076579090e-21 5.156588971631447031e-22 1.272916507021829524e-21 9.925098357530474115e-22 2.900411786499633534e-20 7.500000000000000000e+01 3.703170744599039612e-20 2.562135370614946519e-20 3.882807946840321710e-21 6.276451064019492568e-23 1.201565433924532727e-20 7.729078539094354029e-22 1.259957813130228922e-21 2.149720735941852152e-21 3.214898920420335270e-21 2.538062410502141153e-21 5.101540460350279236e-22 8.383146270656862879e-22 9.811526419250997024e-22 2.900722420872507827e-20 7.510000000000000853e+01 3.756232295134828280e-20 2.562202274395684516e-20 3.860100302700283559e-21 6.237302127846342065e-23 1.200769082988323525e-20 7.701765952517370171e-22 1.256704806111488947e-21 2.146319924803806831e-21 3.074127490904186484e-21 1.768459482748089489e-21 4.892609734000731349e-22 7.884669529395956059e-22 9.697954480971501125e-22 2.892637878987543453e-20 7.520000000000000284e+01 3.807164920548722436e-20 2.562269640331019276e-20 3.819549190029005681e-21 6.198701695099150643e-23 1.200001685687083373e-20 7.674454359695633109e-22 1.253451799092749350e-21 2.142923144303242808e-21 2.675830813452685310e-21 2.004683618826911637e-21 4.785157587858818648e-22 6.770835829584145935e-22 9.584382542692022154e-22 2.889035925373239709e-20 7.529999999999999716e+01 3.550843800898709133e-20 2.562337468384498364e-20 3.873984458088497532e-21 6.160396610350532861e-23 1.199228278364309419e-20 7.647143771276660647e-22 1.250198792074009940e-21 2.139526056658145797e-21 2.941484294917639985e-21 1.437412495713685571e-21 4.910417437845133679e-22 9.147903181013361887e-22 9.470810604412545063e-22 2.889294887031242358e-20 7.540000000000000568e+01 3.597009265382543747e-20 2.562405758519424087e-20 4.024855031715907698e-21 6.122285232245787445e-23 1.198420202107701742e-20 7.619834198060222497e-22 1.246945785055269966e-21 2.136108295903588528e-21 3.133559683656633914e-21 1.498457689471612449e-21 4.930862512554991739e-22 5.046230683008691401e-22 9.357238666133049165e-22 2.892322616920577623e-20 7.550000000000000000e+01 3.769980044039724594e-20 2.562474510698853798e-20 4.157897208906987009e-21 6.084648101441337477e-23 1.197612191811899945e-20 7.592525651001080594e-22 1.243692778036530368e-21 2.132694531845121656e-21 2.798450602961560934e-21 1.272729069768293212e-21 4.924708232876958094e-22 1.437349979555250742e-21 9.244486876621198468e-22 2.892460482968906064e-20 7.560000000000000853e+01 3.614494726444834557e-20 2.562543724885597189e-20 4.168786790410520264e-21 6.047010970636987425e-23 1.196846470842459053e-20 7.565218141211740691e-22 1.240439771017790394e-21 2.129310757171337027e-21 2.762530378285577379e-21 8.519453859781427442e-22 5.114372308432239080e-22 1.635172031417911694e-21 9.137745422526199936e-22 2.891474237392462965e-20 7.570000000000000284e+01 3.435716163657954141e-20 2.562613401042219296e-20 4.159239411148174747e-21 6.010137815296241696e-23 1.196086224939393138e-20 7.537911679965329028e-22 1.237186763999050796e-21 2.125934315055955402e-21 3.085330529192074829e-21 7.974107191552557312e-22 5.060523612939874879e-22 1.584418585670998227e-21 9.031003968431216450e-22 2.893820093843174492e-20 7.579999999999999716e+01 3.559034170828947059e-20 2.562683539131039001e-20 4.085208681933627843e-21 5.973331092604567237e-23 1.195326025403462428e-20 7.510606278698466185e-22 1.233933756980311386e-21 2.122562020052307038e-21 2.919342108660801295e-21 3.303421887483133471e-22 5.176586939495614704e-22 1.617739736704550375e-21 8.924262514336232964e-22 2.890004734134794845e-20 7.590000000000000568e+01 3.519762140655001497e-20 2.562754139114129625e-20 3.943356913441818208e-21 5.936705882517963939e-23 1.194565903676799600e-20 7.483301949014249071e-22 1.230680749961571412e-21 2.119193891958416868e-21 2.921713390906319486e-21 8.634844042640001613e-22 4.961797316216285400e-22 1.426644075712591669e-21 8.817521060241232551e-22 2.887784272740617599e-20 7.600000000000000000e+01 3.577750188291500051e-20 2.562825200953318336e-20 3.788724252647434796e-21 5.900235294280144902e-23 1.193791672854704333e-20 7.455998702685291224e-22 1.227427742942831814e-21 2.115829950673832661e-21 3.906168413057900884e-21 9.447018336796346857e-22 4.768534159693860004e-22 1.699220435294736558e-21 8.710779606146249065e-22 2.898693556311563403e-20 7.610000000000000853e+01 3.672433616277801433e-20 2.562896724610187344e-20 3.499606578058869613e-21 5.863896234469658095e-23 1.192991143838063473e-20 7.428696551656795087e-22 1.224174735924091840e-21 2.112470216200038802e-21 3.313015405077930307e-21 7.644743325628232137e-22 5.000594129182099452e-22 1.400030981400745859e-21 8.604038152051250533e-22 2.885205982683764968e-20 7.620000000000000284e+01 3.583083807116274169e-20 2.562968710046073908e-20 3.199350675267054823e-21 5.828247698902340768e-23 1.192193976712457688e-20 7.401395508049752168e-22 1.220921728905352242e-21 2.109114708640874952e-21 3.921421467656446737e-21 9.014642042535492094e-22 5.051893311572964954e-22 1.714461178273964361e-21 8.497296697956267047e-22 2.891100810224907943e-20 7.629999999999999716e+01 3.628082035208018939e-20 2.563041157222068824e-20 3.256247737154698555e-21 5.792599163335121007e-23 1.191440585354691971e-20 7.374095584164144149e-22 1.217668721886612832e-21 2.105763448202946437e-21 3.021882850411010328e-21 5.112090090037040143e-22 5.111924869155032752e-22 1.832455327672809605e-21 8.390555243861283562e-22 2.880372603840820117e-20 7.640000000000000568e+01 3.479755108249752580e-20 2.563114066099018540e-20 3.668822170235203513e-21 5.757450000152829675e-23 1.190687472451144774e-20 7.346796792482270006e-22 1.214415714867872858e-21 2.102416455196038775e-21 2.595370471355128223e-21 1.135197565227887344e-21 4.824011799949349786e-22 2.271952116720803583e-21 8.286187697423407224e-22 2.885711404003549981e-20 7.650000000000000000e+01 3.582455908998801890e-20 2.563187436637524848e-20 4.038790801868616973e-21 5.722450000150524666e-23 1.189934459828665401e-20 7.319499145672129550e-22 1.211162707849133260e-21 2.099073750033530700e-21 2.741100389471149225e-21 1.323759016433802830e-21 5.070515559481745909e-22 1.945346883957666986e-21 8.185859196370553182e-22 2.890136321254356162e-20 7.660000000000000853e+01 3.729033685027126945e-20 2.563261268797943985e-20 4.116481229084569907e-21 5.687626556164831470e-23 1.189181456304656448e-20 7.292202656590863395e-22 1.207909700830393286e-21 2.095735353232801914e-21 2.595687741171222467e-21 9.385122785274674159e-22 5.136450613059121685e-22 2.352670415106948712e-21 8.085530695317685034e-22 2.891104809045885574e-20 7.670000000000000284e+01 3.553955071618794376e-20 2.563335562540387234e-20 4.147581393943256160e-21 5.653103734585822566e-23 1.188408757936409925e-20 7.264907338288308594e-22 1.204656693811653876e-21 2.092426506496421046e-21 3.109776828502491633e-21 1.247716516035691267e-21 5.132653187721418922e-22 1.751969940787299612e-21 7.985202194264831933e-22 2.893201174375107315e-20 7.680000000000001137e+01 3.528301167825171790e-20 2.563410317824720922e-20 4.041679770122316296e-21 5.618580913006859507e-23 1.187615587427566235e-20 7.237613204010580603e-22 1.201403686792913714e-21 2.089334903157535341e-21 3.790187801869890976e-21 7.946754879181345565e-22 5.156874722682293436e-22 2.582588298755559200e-21 7.884873693211963785e-22 2.904093006161517162e-20 7.690000000000000568e+01 3.338291667348636817e-20 2.563485534610567929e-20 3.792147016097860333e-21 5.584695435826248976e-23 1.186831471134127550e-20 7.210320267203806653e-22 1.198150679774174304e-21 2.086252469863575452e-21 3.044271965437949652e-21 1.385001858586432012e-21 5.224970792648251619e-22 2.914168278539276147e-21 7.784545192159109743e-22 2.896983423356159849e-20 7.700000000000000000e+01 3.453753517259810980e-20 2.563561212857305577e-20 3.579763090395745938e-21 5.550836514662311797e-23 1.186085138966532335e-20 7.183028541517861939e-22 1.194897672755434706e-21 2.083197418412917402e-21 3.142018574978635435e-21 1.184563047015854238e-21 5.419555159989214364e-22 2.675903260639560978e-21 7.684216691106256642e-22 2.891860572399883539e-20 7.710000000000000853e+01 3.540125858136740057e-20 2.563637352524067739e-20 3.602556828234382742e-21 5.517327272864642945e-23 1.185338956081436307e-20 7.155738040810258160e-22 1.191644665736694732e-21 2.080146094138089390e-21 3.409068533412900318e-21 1.264741047808540871e-21 5.284230191940697763e-22 2.764338916916942835e-21 7.583888190053388494e-22 2.896004651873500137e-20 7.720000000000000284e+01 3.503363846734762540e-20 2.563713953569741528e-20 3.656409509713094132e-21 5.484104132366736767e-23 1.184595686274174088e-20 7.128448779150094115e-22 1.188391658717955323e-21 2.077098513465114694e-21 3.228265776789258753e-21 1.310616284555262263e-21 5.169794080994828932e-22 1.651932035297858419e-21 7.483559689000534453e-22 2.885987379014626529e-20 7.730000000000001137e+01 3.538259102954445575e-20 2.563791015952973016e-20 3.774484563485388490e-21 5.450962963096263837e-23 1.183852802831571377e-20 7.101160770822081538e-22 1.185138651699215348e-21 2.074054692896346612e-21 3.001013917563517041e-21 2.798597426959113931e-21 5.108717934549772218e-22 1.806753847006858840e-21 7.386387442185018834e-22 2.896243391567650356e-20 7.740000000000000568e+01 3.711577861690116166e-20 2.563868539632163019e-20 3.956983178475995831e-21 5.418370370501670711e-23 1.183109828430880826e-20 7.073874030330700709e-22 1.181885644680475751e-21 2.071014649010736288e-21 2.675572777462573648e-21 3.154426503071414447e-21 5.099958742257539823e-22 1.751709596121773175e-21 7.292142057014359829e-22 2.898505669157739408e-20 7.750000000000000000e+01 3.727725568378610196e-20 2.563946524565467398e-20 4.109925307784258177e-21 5.385777777907110499e-23 1.182366878242304000e-20 7.046588572404404016e-22 1.178632637661736153e-21 2.067978398464089248e-21 3.307110863512514789e-21 3.916238006679858279e-21 5.216578408808646334e-22 2.196284048050261527e-21 7.197896671843699884e-22 2.919119305523018662e-20 7.760000000000000853e+01 3.644533552729962601e-20 2.564029650720337130e-20 4.014916645689756328e-21 5.353508196848687678e-23 1.181624230601267607e-20 7.021109841535719341e-22 1.175552337958554326e-21 2.064945957989328340e-21 3.015471705355897499e-21 4.256674935645218093e-21 5.248458253985692694e-22 2.403811699788583328e-21 7.103651286673027714e-22 2.920754076243617006e-20 7.770000000000000284e+01 3.292807053297578703e-20 2.564119925011885693e-20 3.895792575852716350e-21 5.321377049305808567e-23 1.180881724764153038e-20 6.998228186314356375e-22 1.172720396108860464e-21 2.061917344396754785e-21 2.904905380896796157e-21 4.335381563703214207e-21 5.218020832152016460e-22 2.174764342566012498e-21 7.009405901502367770e-22 2.917092777334152051e-20 7.780000000000001137e+01 3.314652050598011211e-20 2.564210599423871146e-20 3.686148384207229719e-21 5.289449796041948974e-23 1.180139252610441724e-20 6.975347150729939714e-22 1.169888454259166414e-21 2.058892574574302084e-21 3.490967658366096986e-21 2.405421787248839322e-21 5.417433989438882019e-22 3.436794469852857311e-21 6.915160516331694659e-22 2.910380269269564647e-20 7.790000000000000568e+01 3.551898730687539505e-20 2.564301673913849605e-20 3.385373114831069599e-21 5.258102857264610749e-23 1.179363328280307852e-20 6.952466740900277043e-22 1.167056512409472552e-21 2.055871665487795190e-21 2.924305156335597992e-21 3.425373172578865393e-21 5.082381085181116475e-22 5.143596364566743548e-21 6.820915131161035655e-22 2.935395181091812717e-20 7.800000000000000000e+01 3.559994546642876998e-20 2.564393148439193619e-20 3.124279946159603401e-21 5.226755918487283692e-23 1.178584511931093589e-20 6.929586963023798036e-22 1.164224570559778689e-21 2.052854634181207425e-21 2.780114983825551779e-21 3.289966825197486017e-21 5.130800987986729179e-22 2.764074454406623137e-21 6.726669745990375710e-22 2.896963596003651797e-20 7.810000000000000853e+01 3.379505670495329251e-20 2.564485022957095483e-20 3.087024581350258806e-21 5.195673469505904571e-23 1.177830468785075031e-20 6.906707823380892531e-22 1.161392628710084451e-21 2.049824517306506699e-21 2.402896031199649285e-21 4.951860700671954276e-21 5.191539116771280304e-22 5.247280933613696502e-21 6.632424360819703540e-22 2.950398391148848976e-20 7.820000000000000284e+01 3.475451935308058427e-20 2.564577297424567839e-20 3.095776730440506337e-21 5.164653061340886367e-23 1.177094371356058254e-20 6.883829328335278813e-22 1.158560686860390589e-21 2.046785948698339912e-21 2.833673330415417428e-21 2.601689135810658202e-21 5.071437758612625560e-22 5.151988668674621405e-21 6.541396829987235408e-22 2.922121364025952642e-20 7.830000000000001137e+01 3.641150109501624425e-20 2.564669971798440967e-20 3.154809522719711023e-21 5.133853658651241716e-23 1.176359145162275216e-20 6.860951484335364361e-22 1.155728745010696350e-21 2.043758270511054947e-21 2.429427228615195925e-21 3.624839528775554353e-21 5.270734063868177612e-22 3.392506024841008688e-21 6.452847375015147548e-22 2.903995534696001501e-20 7.840000000000000568e+01 3.437651195979334915e-20 2.564763046035363990e-20 3.272235737914106097e-21 5.103447154584512966e-23 1.175626478533092825e-20 6.838074297915679013e-22 1.152896803161002676e-21 2.040756821286496511e-21 2.385809340835208544e-21 3.724012412379866816e-21 5.145612335967044504e-22 2.201841001296836626e-21 6.364297920043071913e-22 2.894409383303411491e-20 7.850000000000000000e+01 3.457252616660553214e-20 2.564856520091806376e-20 3.385592583585138185e-21 5.073040650517789506e-23 1.174893832829974200e-20 6.815197775698294963e-22 1.150064861311308814e-21 2.037759336079146341e-21 2.579977475995043068e-21 2.941651565497803854e-21 5.141272386605124839e-22 3.493504412890009839e-21 6.275748465070997219e-22 2.900798491322943601e-20 7.860000000000000853e+01 3.141350861490541994e-20 2.564950393924056138e-20 3.409451555478328122e-21 5.043073170841359857e-23 1.174163779476370276e-20 6.792321924394305063e-22 1.147232919461614575e-21 2.034765832407604762e-21 2.722575283518415097e-21 1.807612151675690166e-21 5.104016617057038504e-22 3.463927283509256433e-21 6.187199010098909358e-22 2.892455323075533859e-20 7.870000000000000284e+01 3.383813439993040712e-20 2.565044667488221933e-20 3.419145610742134075e-21 5.013154471652750363e-23 1.173434067724344893e-20 6.769446750805328393e-22 1.144400977611920713e-21 2.031776327870377128e-21 2.857851566702567412e-21 2.300114041429024356e-21 5.083704421326646417e-22 1.410287540187679334e-21 6.098649555126833723e-22 2.879768020629928104e-20 7.880000000000001137e+01 3.465539768750306246e-20 2.565139340740229456e-20 3.498954801757148395e-21 4.983483871074182613e-23 1.172704562137240553e-20 6.746572261825010196e-22 1.141569035762226475e-21 2.028790840146116819e-21 2.145703157740769320e-21 2.201076455441303095e-21 5.164698265493797099e-22 1.638570518623981803e-21 6.010100100154745863e-22 2.874715172907548664e-20 7.890000000000000568e+01 3.419555071149641974e-20 2.565234413635827457e-20 3.650748426464877165e-21 4.954129032362936554e-23 1.171975311444359833e-20 6.723698464440617729e-22 1.138737093912532801e-21 2.025809386993868615e-21 2.406905349503037879e-21 1.653303819102363504e-21 5.139083197760748543e-22 3.194794514733328781e-21 5.921550645182670228e-22 2.887778673082485508e-20 7.900000000000000000e+01 3.472194269146636506e-20 2.565329886130581423e-20 3.801435404318541313e-21 4.924774193651706951e-23 1.171246596655429722e-20 6.700825365734601316e-22 1.135905152062838938e-21 2.023014210127895354e-21 2.509649707931718372e-21 1.734340340689505819e-21 5.139224412805208736e-22 2.721501467826762330e-21 5.833001190210594593e-22 2.885959145918201984e-20 7.910000000000000853e+01 3.898384605164692190e-20 2.565425758179878691e-20 3.942958528154685957e-21 4.895883871069547666e-23 1.170520341248211075e-20 6.677952972886223114e-22 1.133073210213144700e-21 2.020301299683421836e-21 2.813362031827137740e-21 2.014315412607393482e-21 5.046509302340597330e-22 2.670096849341217118e-21 5.747166512832389623e-22 2.891712852623664973e-20 7.920000000000000284e+01 3.887277059660884537e-20 2.565522029738926042e-20 4.085810618806752104e-21 4.867012903326105988e-23 1.169794102939387491e-20 6.655081293173233842e-22 1.130241268363450838e-21 2.017591789561144233e-21 2.769769555905182324e-21 1.109855883185368249e-21 5.034104470137805626e-22 3.523376695563120987e-21 5.663969139204828039e-22 2.897259407454788599e-20 7.930000000000001137e+01 3.711116744503121273e-20 2.565618700762750004e-20 3.993994272505808531e-21 4.838428915761487649e-23 1.169070351599650235e-20 6.632210333973529753e-22 1.127409326513756599e-21 2.014885693478774676e-21 2.437771184899158479e-21 9.387527510953332088e-22 5.061765577699527652e-22 2.767136042463696755e-21 5.580771765577254230e-22 2.883896984709604977e-20 7.940000000000000568e+01 3.754565583143796695e-20 2.565715771206197147e-20 3.665490226785433103e-21 4.810155823390561728e-23 1.168347285789882924e-20 6.609340102766908354e-22 1.124577384664062925e-21 2.012183025210487765e-21 2.758582591459661694e-21 1.204572135425764156e-21 5.109909599080928059e-22 4.244313744535323883e-21 5.497574391949691706e-22 2.901068970122711956e-20 7.950000000000000000e+01 3.854471774884746632e-20 2.565813241023935597e-20 3.366457910984374994e-21 4.781882731019659906e-23 1.167624239945648602e-20 6.586470607136810961e-22 1.121745442814369063e-21 2.009471467101566687e-21 3.129330677897856552e-21 6.355102954737928588e-22 5.134832616046466600e-22 4.498976549306015703e-21 5.414377018322130122e-22 2.902988148250827747e-20 7.960000000000000853e+01 3.683788316286398466e-20 2.565911110170451715e-20 3.364621083662757197e-21 4.754038400094559060e-23 1.166901413761574859e-20 6.563601854772116969e-22 1.118913500964674824e-21 2.006746279643053630e-21 3.050917824980177439e-21 9.265179590209442192e-22 5.118372059747507633e-22 2.984354912349975716e-21 5.331179644694556313e-22 2.883067319332503449e-20 7.970000000000000284e+01 3.684882249583480848e-20 2.566009378600054319e-20 3.391628283879730599e-21 4.726198400093162945e-23 1.166178846403407049e-20 6.540733853469003019e-22 1.116081559114980962e-21 2.004025660638582134e-21 2.532282937095924186e-21 1.246206295419842100e-21 5.125649368018308027e-22 3.257784208009109426e-21 5.247982271066994729e-22 2.882272452822074216e-20 7.980000000000001137e+01 3.484025062014943665e-20 2.566108046266871669e-20 3.573119461879178838e-21 4.698647012044012414e-23 1.165462023406719446e-20 6.517866611132783349e-22 1.113249617265286724e-21 2.001336748369257389e-21 2.984622531319093156e-21 1.440324717335586787e-21 5.106226818718094723e-22 2.866638740528742588e-21 5.164784897439420920e-22 2.885286334559494557e-20 7.990000000000000568e+01 3.861247340137220683e-20 2.566207113124853576e-20 3.916648766641925274e-21 4.671396016026736251e-23 1.164745238552401369e-20 6.495000135779853590e-22 1.110417675415593050e-21 1.998651333506534253e-21 2.165918530523569936e-21 1.301643473087798890e-21 5.046660018131106204e-22 1.276968728771254156e-21 5.081587523811858396e-22 2.870062521000588444e-20 8.000000000000000000e+01 4.430518832464605926e-20 2.566306579127769598e-20 4.235991287861215412e-21 4.644145020009485361e-23 1.164026578331222148e-20 6.472134435539614820e-22 1.107585733565899187e-21 1.995969430166841628e-21 2.159102230853035403e-21 1.359623808243365685e-21 4.973559794827311753e-22 1.543712694661271713e-21 5.000136834346724116e-22 2.875855981370467443e-20 8.010000000000000853e+01 3.779833809714265946e-20 2.566406444229211743e-20 4.154700352623028938e-21 4.617206374589853580e-23 1.163307028698023508e-20 6.449269518656485065e-22 1.104753791716204949e-21 1.993291052524073730e-21 2.714965312891923128e-21 1.369145869324832739e-21 5.219740425466516102e-22 2.151843200146643102e-21 4.922008963805959630e-22 2.883117341795736882e-20 8.020000000000000284e+01 3.502820058836912576e-20 2.566506708382592368e-20 4.049245958098470213e-21 4.590274103672234429e-23 1.162588974376932424e-20 6.426405393491938079e-22 1.101921849866511087e-21 1.990616214809725502e-21 2.550266709506368153e-21 1.217110891284509165e-21 5.030012741501463154e-22 2.175224693221910445e-21 4.843881093265205488e-22 2.879322343855624098e-20 8.030000000000001137e+01 3.778987596474941120e-20 2.566607371541143274e-20 3.930574430861423995e-21 4.563664822219717759e-23 1.161875393747422662e-20 6.403542068526566571e-22 1.099089908016816848e-21 1.987944931313026528e-21 2.512780436659219061e-21 7.818276552165018640e-22 5.046126697377702355e-22 2.525868754314497809e-21 4.765753222724441001e-22 2.878456790060223172e-20 8.040000000000000568e+01 3.579339277289127353e-20 2.566708433657919919e-20 3.791119040428458994e-21 4.537419762929932771e-23 1.161161869341143855e-20 6.380679552362222547e-22 1.096257966167122986e-21 1.985277216381076070e-21 2.751788818888756008e-21 1.497520646475308982e-21 5.074396657047292717e-22 2.129023722346377445e-21 4.687625352183686859e-22 2.878156827585975287e-20 8.050000000000000000e+01 3.830313777393891496e-20 2.566809894685798407e-20 3.664962581802597903e-21 4.511174703640188337e-23 1.160483174482597424e-20 6.357817853724175513e-22 1.093426024317429312e-21 1.982613084418974730e-21 2.150569039559467167e-21 1.762758436174084208e-21 4.928539111103975937e-22 2.911403429226671333e-21 4.609497481642932716e-22 2.879499742720736593e-20 8.060000000000000853e+01 3.656728825716290381e-20 2.566911754577475491e-20 3.690409359434261777e-21 4.485226877552025870e-23 1.159811128948986540e-20 6.334956981463328991e-22 1.090594082467735073e-21 1.979952549889953842e-21 2.636880679572192955e-21 1.922771382731247488e-21 4.915390717796896314e-22 2.304526149609986469e-21 4.531369611102168230e-22 2.879166220328213245e-20 8.070000000000000284e+01 3.769631182185553540e-20 2.567014013285470379e-20 3.733694691191639981e-21 4.459298023795908160e-23 1.159123775046779804e-20 6.312096944558499098e-22 1.087762140618041211e-21 1.977283061598964171e-21 2.789339274464339226e-21 1.605018741061747322e-21 5.009481950464901698e-22 2.920435670171245292e-21 4.453241740561415028e-22 2.884582046038501142e-20 8.080000000000001137e+01 3.444024755002635273e-20 2.567116670762123828e-20 3.694483347634442787e-21 4.433563636442978996e-23 1.158416218443834478e-20 6.289237752118699704e-22 1.084930198768346973e-21 1.974600487114867179e-21 2.601736379029343885e-21 7.479021424057374462e-22 5.161200913025055555e-22 4.021645560872628600e-21 4.375113870020649601e-22 2.891858003456707779e-20 8.090000000000000568e+01 3.506938766660833153e-20 2.567219726959597542e-20 3.575577537588443159e-21 4.408109090987283740e-23 1.157708817624516081e-20 6.266379413385537620e-22 1.082098256918653110e-21 1.971921475568505863e-21 2.164481824380137178e-21 1.167583104004014743e-21 4.774258335321608127e-22 3.374212701367292067e-21 4.297345762405007013e-22 2.879540966320648843e-20 8.100000000000000000e+01 3.743047770638543610e-20 2.567323181829876284e-20 3.489991821159409920e-21 4.382654545531622573e-23 1.156998546562934281e-20 6.243521937735602144e-22 1.079266315068959436e-21 1.969275380902890926e-21 2.312726165474427525e-21 1.056378312567897838e-21 4.782182235018649307e-22 3.392162109100521252e-21 4.223973432520185302e-22 2.879188340019453902e-20 8.110000000000000853e+01 3.838257014667750768e-20 2.567427035324765762e-20 3.665344733501835205e-21 4.357513725566150569e-23 1.156288284316228513e-20 6.220665334682935480e-22 1.076434373219265198e-21 1.966632956738765930e-21 2.436002693167697931e-21 2.113638714519839332e-21 4.801522884746753678e-22 2.370166076051639678e-21 4.150601102635353247e-22 2.877743000378505450e-20 8.120000000000000284e+01 3.740332569606668265e-20 2.567531287395895343e-20 3.864372342615749535e-21 4.332415686349377137e-23 1.155581373780470097e-20 6.197809613881569923e-22 1.073602431369571336e-21 1.963994217891382708e-21 2.561424651553021672e-21 7.443351779045697154e-22 4.836338450168084170e-22 2.799302343000307978e-21 4.077228772750531066e-22 2.878261560669892161e-20 8.130000000000001137e+01 3.757084940834899880e-20 2.567642546012863812e-20 3.989689578629707029e-21 4.307524705956151768e-23 1.154876946551785011e-20 6.177647664359825487e-22 1.071039051898174322e-21 1.961482680961201550e-21 2.701893300597991890e-21 1.584533262736012185e-21 4.803220351161591812e-22 2.437291915354347761e-21 4.003856442865699011e-22 2.881129872330923508e-20 8.140000000000000568e+01 3.547421395873913292e-20 2.567756574261440760e-20 4.049224031815092628e-21 4.283054117719793102e-23 1.154172638786284648e-20 6.158468854976785824e-22 1.068573673067496455e-21 1.959059685615570004e-21 2.951869031041958037e-21 1.572131900200012878e-21 4.778657433458775016e-22 2.804661753921287199e-21 3.930484112980876830e-22 2.887455647955242343e-20 8.150000000000000000e+01 3.643119511993679962e-20 2.567870954575901577e-20 4.085460720440482471e-21 4.258583529483469113e-23 1.153468347617964204e-20 6.139290472088576655e-22 1.066108294236818400e-21 1.956639850742125186e-21 2.389698822522525161e-21 1.617741640618347726e-21 4.968698318332256704e-22 2.061860050436582415e-21 3.857111783096055119e-22 2.876550804430364419e-20 8.160000000000000853e+01 3.686881830946036861e-20 2.567985686909202415e-20 3.842118398586976257e-21 4.234382879448098516e-23 1.152764182694648780e-20 6.120112519704674734e-22 1.063642915406140158e-21 1.954223188081317984e-21 2.367611037973518242e-21 1.353762365935465932e-21 5.047975641528295560e-22 3.123273056855814192e-21 3.783739453211223064e-22 2.881008852069695404e-20 8.170000000000000284e+01 3.885473604148016529e-20 2.568100771214164009e-20 3.566016052079679828e-21 4.210258365828417714e-23 1.152090591041586517e-20 6.100935001884883960e-22 1.061177536575462103e-21 1.951809709416318062e-21 2.221960079026716004e-21 1.637943770464197292e-21 4.823738019804385749e-22 1.814681863328644685e-21 3.710367123326400882e-22 2.866277962068004241e-20 8.180000000000001137e+01 3.545055500259208480e-20 2.568216207443468668e-20 3.333664448500847561e-21 4.186231906683455411e-23 1.151430082750215663e-20 6.081757922740111204e-22 1.058712157744783860e-21 1.949399426573084212e-21 2.438441224588663420e-21 1.279791443817280858e-21 4.943355598355883804e-22 2.876154661128665556e-21 3.636994793441568827e-22 2.871918040546177591e-20 8.190000000000000568e+01 3.749366952975084132e-20 2.568331995549664789e-20 3.148324479105724179e-21 4.162574319133833701e-23 1.150760043983946618e-20 6.062581286433197615e-22 1.056246778914105806e-21 1.946992351420437319e-21 2.213660304382580650e-21 8.716573019214319196e-22 4.810186717288880599e-22 2.301178354408556587e-21 3.567494912760975209e-22 2.861048070754332522e-20 8.200000000000000000e+01 3.529519999483472607e-20 2.568448135485161738e-20 3.042223208936650642e-21 4.138916731584242555e-23 1.150061558114092104e-20 6.043405097179715142e-22 1.053781400083427939e-21 1.944588495870129581e-21 2.430719921249599736e-21 1.464912102415800563e-21 4.790851923649020445e-22 1.795296149267877898e-21 3.499660044968950685e-22 2.860244984841282636e-20 8.210000000000000853e+01 3.503851098743520261e-20 2.568564627202236779e-20 3.357053336406746797e-21 4.115516279135542279e-23 1.149363251616344824e-20 6.024229359248810061e-22 1.051316021252749697e-21 1.942187871876914473e-21 2.112730882432210582e-21 1.220202476541271205e-21 4.807564208791761147e-22 2.057493476960761507e-21 3.431825177176916286e-22 2.861647239665761372e-20 8.220000000000000284e+01 3.528416009685985486e-20 2.568681470653028145e-20 3.743960074800092748e-21 4.092260465181124711e-23 1.148665052248248629e-20 6.005054076964068145e-22 1.048850642422071642e-21 1.939767247918471953e-21 2.056265764389511193e-21 1.323319940356528847e-21 4.875677119589465077e-22 2.644036057256826832e-21 3.363990309384891292e-22 2.871095802820930605e-20 8.230000000000001137e+01 3.467240309252529733e-20 2.568798665789539253e-20 4.036878626851054163e-21 4.069023255877875773e-23 1.147966868209233273e-20 5.985879254704361015e-22 1.046385263591393399e-21 1.937343636179062516e-21 2.647326031187445595e-21 1.566973824992661152e-21 4.767507927127638742e-22 2.960766348205998699e-21 3.296155441592856893e-22 2.883965747883263253e-20 8.240000000000000568e+01 3.350232281679203652e-20 2.568916212563637804e-20 4.232607782633233637e-21 4.046077519442858189e-23 1.147282966981154492e-20 5.966704896904756447e-22 1.043919884760715345e-21 1.934932952724484946e-21 2.138965308558340044e-21 6.778893241345102421e-22 4.903465397292433400e-22 2.650187492892102585e-21 3.228320573800832369e-22 2.875879148255452751e-20 8.250000000000000000e+01 3.287288504060249103e-20 2.569034110927056685e-20 4.374854980521001504e-21 4.023131783007867641e-23 1.146628048712138390e-20 5.947531008057392936e-22 1.041454505930037478e-21 1.932545285728809097e-21 2.111814843419800610e-21 8.579937870706048872e-22 4.931137443820320267e-22 2.560986278124415157e-21 3.160485706008807374e-22 2.877291943915203413e-20 8.260000000000000853e+01 3.187573324430710250e-20 2.569152360831392159e-20 4.244685786374073284e-21 4.000403692368936833e-23 1.145973210232953480e-20 5.928357592712419155e-22 1.038989127099359047e-21 1.930160910613607385e-21 2.284534126619652938e-21 1.323936762787196654e-21 4.965826974006686367e-22 2.725455856211449592e-21 3.092650838216772976e-22 2.879752646192772699e-20 8.270000000000000284e+01 3.409176808475665463e-20 2.569270962228105375e-20 4.063497883404125123e-21 3.977911384675770127e-23 1.145286061420825395e-20 5.909184655478934348e-22 1.036523748268681181e-21 1.927779839593570631e-21 2.093545318615797773e-21 8.521876333784151904e-22 4.900749798334921801e-22 3.033130893173025909e-21 3.024815970424748451e-22 2.876764762740200394e-20 8.280000000000001137e+01 3.706081607196943306e-20 2.569389915068522968e-20 3.817968797422281712e-21 3.955419076982606360e-23 1.144593653916069585e-20 5.890012201025920261e-22 1.034058369438002938e-21 1.925402084926842322e-21 2.261160153942080496e-21 1.232579027448905338e-21 4.833889220638579105e-22 3.332118063705311248e-21 2.957785920674527045e-22 2.879138753777169952e-20 8.290000000000000568e+01 3.461198357297799818e-20 2.569509219303834650e-20 3.514253872088588801e-21 3.933265230827920016e-23 1.143902369857384529e-20 5.870840234083243607e-22 1.031592990607324884e-21 1.923027658915078422e-21 2.058558661985257564e-21 9.646521087805327919e-22 5.078114003447914114e-22 3.432167106604832348e-21 2.893706560804211424e-22 2.873738047812387665e-20 8.300000000000000000e+01 3.665023165509873227e-20 2.569628874885097126e-20 3.260787625769743538e-21 3.911157538519410630e-23 1.143212814039606889e-20 5.851668759442628432e-22 1.029127611776647017e-21 1.920656573903501911e-21 2.104583089098570955e-21 8.717516673620688970e-22 5.020646461009249132e-22 3.253111884119535750e-21 2.829627200933895333e-22 2.868486735573759888e-20 8.310000000000000853e+01 3.521767700705103966e-20 2.569748881763231080e-20 3.305980098009542182e-21 3.889167969405711803e-23 1.142523260909324406e-20 5.832497781958677384e-22 1.026662232945968586e-21 1.918288842280959587e-21 2.275974847542414434e-21 4.576908537279879394e-22 4.941919877348813020e-22 2.969400298819014922e-21 2.765547841063570307e-22 2.866059185066429370e-20 8.320000000000000284e+01 3.561050495844499379e-20 2.569869239889021478e-20 3.396651828200317934e-21 3.867482145650131442e-23 1.141871681019457759e-20 5.813327306549909914e-22 1.024196854115290720e-21 1.915924476479975482e-21 2.101598883252221661e-21 8.767081934429554525e-22 4.935199653701883141e-22 3.203146842032761054e-21 2.701468481193254216e-22 2.869091047034311745e-20 8.330000000000001137e+01 3.454331917386328030e-20 2.569989949213119978e-20 3.493960310643044418e-21 3.845796321894553432e-23 1.141224811757718156e-20 5.794157338199800468e-22 1.021731475284612289e-21 1.913563488976800886e-21 2.226102394629911023e-21 1.025853806137111237e-21 4.819421102990587689e-22 2.500754385588904700e-21 2.637389121322929191e-22 2.864504090602842044e-20 8.340000000000000568e+01 3.604159139385702062e-20 2.570111009686043118e-20 3.595983259512750227e-21 3.824370534405841284e-23 1.140562583733966364e-20 5.774987881957868406e-22 1.019266096453934422e-21 1.911205892291467393e-21 2.069796603626422864e-21 1.207907819191210857e-21 4.849492770099638662e-22 2.321335296371211005e-21 2.573309761452613099e-22 2.863609832353711140e-20 8.350000000000000000e+01 3.649865028397590291e-20 2.570232421258171120e-20 3.666804393030595951e-21 3.803072824481414228e-23 1.139876098803747928e-20 5.755818942940763221e-22 1.016800717623256556e-21 1.908851698987832785e-21 2.257430935883434073e-21 8.444811932710917716e-22 4.955822432126903526e-22 1.781709582272254857e-21 2.509230401582297008e-22 2.860575487367425251e-20 8.360000000000000853e+01 3.598006168427267775e-20 2.570354183879752399e-20 3.492295605608519211e-21 3.781794372676743118e-23 1.139189625237927359e-20 5.736650526333378906e-22 1.014335338792578125e-21 1.906500921673630689e-21 2.635026998422032545e-21 8.092168710367973466e-22 4.940392249661045888e-22 3.337926439116344413e-21 2.445151041711971982e-22 2.875206862376679703e-20 8.370000000000000284e+01 3.403880348030667745e-20 2.570476297500899951e-20 3.306308630250050801e-21 3.760881825147490219e-23 1.138540953705529753e-20 5.717482637390008758e-22 1.011869959961900259e-21 1.904294274140855871e-21 2.401925969787702358e-21 8.641239783842587691e-22 5.075922389594381961e-22 5.166397294558178304e-21 2.381071681841655891e-22 2.897920908529417995e-20 8.380000000000001137e+01 3.650829933452824725e-20 2.570598762071591359e-20 3.285248399960056427e-21 3.739969277618239083e-23 1.137896971854855197e-20 5.698315281435489844e-22 1.009404581131221828e-21 1.902126776366490461e-21 2.281407815525436472e-21 6.673920554435058616e-22 5.001500757713873358e-22 3.649137279584684211e-21 2.319190402074170704e-22 2.872812336808513875e-20 8.390000000000000568e+01 3.664716848385858422e-20 2.570721577541669989e-20 3.426324483447982547e-21 3.719184486742993768e-23 1.137237880692485367e-20 5.679148463866401058e-22 1.006939202300543961e-21 1.899973270021581077e-21 2.055008663887471074e-21 6.827380191754081599e-22 5.004952580864738728e-22 2.316460125192498055e-21 2.258660073638466538e-22 2.858734104262996526e-20 8.400000000000000000e+01 3.760553485983416922e-20 2.570844743860847404e-20 3.566424089878726277e-21 3.698576121723275515e-23 1.136554128259164918e-20 5.659982190152265894e-22 1.004473823469865907e-21 1.897840874796015392e-21 2.097294226941511619e-21 9.914081967950511152e-22 5.086626199619277960e-22 2.611380217825602384e-21 2.198129745202762373e-22 2.864017395287955311e-20 8.410000000000000853e+01 3.469596980779087381e-20 2.570968260978698845e-20 3.692898845120410723e-21 3.677967756703555498e-23 1.135870389688306784e-20 5.640816465836784358e-22 1.002008444639187664e-21 1.895711370286770521e-21 1.913247710009877202e-21 8.568982654594838337e-22 4.983155923006490560e-22 2.703014754265338667e-21 2.137599416767049744e-22 2.864538027860297235e-20 8.420000000000000284e+01 3.360318770298318656e-20 2.571092128844667146e-20 3.822957345904067494e-21 3.657720754765863090e-23 1.135225875249881862e-20 5.621651296539108150e-22 9.995430658085097974e-22 1.893584766246449888e-21 2.171425975886290888e-21 7.243421285680948895e-22 4.702774684328065558e-22 2.826882086951895998e-21 2.077069088331345578e-22 2.868689073364800154e-20 8.430000000000001137e+01 3.515896578367593716e-20 2.571216347408060328e-20 3.772234723510759408e-21 3.637569811368956589e-23 1.134587256923614863e-20 5.602486687955097967e-22 9.970776869778313667e-22 1.891461072458202839e-21 2.292700453895826217e-21 7.527603547655898558e-22 5.021819701269280937e-22 2.603609365488518531e-21 2.016538759895632949e-22 2.866802533515566821e-20 8.440000000000000568e+01 3.804361902134301013e-20 2.571340916618052195e-20 3.548170553922203250e-21 3.617459018915458727e-23 1.133935207645768442e-20 5.583322645858665452e-22 9.946123081471535001e-22 1.889340298735747595e-21 2.099180536172547944e-21 9.607127538591997231e-22 4.977344049330084002e-22 3.204225270092230284e-21 1.956008431459928783e-22 2.868979472557558098e-20 8.450000000000000000e+01 3.643131217751852180e-20 2.571465836423684748e-20 3.332211584700174205e-21 3.597594867971407928e-23 1.133256993863560628e-20 5.564159176103088803e-22 9.921469293164754455e-22 1.887222454923390806e-21 2.130506296754853023e-21 8.014130876827895291e-22 4.826801390003167383e-22 2.388517847952356682e-21 1.895478103024224853e-22 2.857947748527342330e-20 8.460000000000000853e+01 3.727959767723278808e-20 2.571591106773865473e-20 3.177565678959247515e-21 3.577730717027355366e-23 1.132578793528057260e-20 5.544996284622379174e-22 9.896815504857972028e-22 1.885107550896046740e-21 2.053852770292845706e-21 1.147294912482701481e-21 4.844887858589304213e-22 2.487415389529744051e-21 1.834947774588512224e-22 2.857464890075949425e-20 8.470000000000000284e+01 3.492056725563143776e-20 2.571716727617368245e-20 3.030788470845359394e-21 3.558050526361379582e-23 1.131934716945881112e-20 5.525833977432698782e-22 9.872161716551191482e-22 1.882995596559256087e-21 1.547569766193372023e-21 6.809435665907800761e-22 4.810679370789639367e-22 2.624524533838291252e-21 1.774417446152808058e-22 2.852231708087811421e-20 8.480000000000001137e+01 3.592916835003285156e-20 2.571842698902833026e-20 3.037112460714968783e-21 3.538561804556236478e-23 1.131298745009443213e-20 5.506672260633746121e-22 9.847507928244409055e-22 1.880886601849202891e-21 2.306240286627072876e-21 8.368918680741172727e-22 4.765553865980035372e-22 2.465222644677332135e-21 1.716959328333415298e-22 2.856239167996968752e-20 8.490000000000000568e+01 3.705666657675870738e-20 2.571969020578768574e-20 3.204941833102353734e-21 3.519073082751105129e-23 1.130663452207540595e-20 5.487511140410245537e-22 9.822854139937630390e-22 1.878772665356527127e-21 2.152552166467857636e-21 4.923024052121354869e-22 4.732767535567275378e-22 3.371353739887055596e-21 1.659793323479461428e-22 2.865143184445759161e-20 8.500000000000000000e+01 3.645045310866319271e-20 2.572095692593548832e-20 3.358329539113922167e-21 3.499868764088677572e-23 1.130029994428905720e-20 5.468350623033401089e-22 9.798200351630849844e-22 1.876640276965399573e-21 2.069442984989484331e-21 9.619010178809466565e-22 4.802127771362260685e-22 2.408496625207961986e-21 1.602627318625507793e-22 2.857603634373492975e-20 8.510000000000000853e+01 3.435454014024586063e-20 2.572225004013251892e-20 3.409320363817089431e-21 3.480722696672340018e-23 1.129396553667824697e-20 5.450172295130041446e-22 9.774569834054369647e-22 1.874510812820360219e-21 2.107794248425559106e-21 8.638140724079894385e-22 4.710928234590465349e-22 2.571398284896807843e-21 1.545461313771545929e-22 2.859415345344583950e-20 8.520000000000000284e+01 3.382915000574518233e-20 2.572359492101005143e-20 3.441142437666725248e-21 3.461633432878359689e-23 1.128734932844783362e-20 5.434073926484911733e-22 9.753107201340311710e-22 1.872405450166543281e-21 2.019004944148294869e-21 9.260109267036999737e-22 4.823167055160327007e-22 2.707425061118552198e-21 1.488295308917592295e-22 2.860457100098992888e-20 8.530000000000001137e+01 3.539552068780072149e-20 2.572494295156271362e-20 3.481469526759905706e-21 3.442842388101653852e-23 1.128062431097502195e-20 5.417975849064964966e-22 9.731644568626250013e-22 1.870311319769478266e-21 1.802517406301482521e-21 1.067793545865181990e-21 4.728749409002668523e-22 2.860208269003567465e-21 1.431129304063630431e-22 2.861293035716340355e-20 8.540000000000000568e+01 3.509438707233732204e-20 2.572629413129539104e-20 3.528853046820302058e-21 3.424051343324955067e-23 1.127397017797624091e-20 5.401878065473837438e-22 9.710181935912192076e-22 1.868220209193862415e-21 1.879450590382807427e-21 5.059637277109922470e-22 4.686837891357858473e-22 2.977236823871763293e-21 1.373963299209676796e-22 2.861842641826842870e-20 8.550000000000000000e+01 3.544327881794936155e-20 2.572764845971191598e-20 3.577779194937727233e-21 3.405389253772154779e-23 1.126766197891505532e-20 5.385780578346236107e-22 9.688719303198132259e-22 1.866132128591355971e-21 2.213940345497289636e-21 1.246670498141915479e-21 4.778079390875822544e-22 2.768431308866702979e-21 1.316797294355722926e-22 2.864874455731186256e-20 8.560000000000000853e+01 3.250000194501227655e-20 2.572900593631506448e-20 3.632630475620567771e-21 3.386866865711888323e-23 1.126135424473166344e-20 5.369683390348418199e-22 9.667256670484070562e-22 1.864047088144364844e-21 2.027418593096070374e-21 8.256675336301446142e-22 4.795298749711546021e-22 2.517895282046108295e-21 1.259631289501761063e-22 2.860196370014808234e-20 8.570000000000000284e+01 3.288968900990181225e-20 2.573036656060655634e-20 3.688902944968344219e-21 3.368344477651641262e-23 1.125482432760143435e-20 5.353586504178661409e-22 9.645794037770012625e-22 1.861965098066047006e-21 2.077979402668373670e-21 6.449748276062720491e-22 4.708726613535872933e-22 2.766616228497244002e-21 1.202767463665211203e-22 2.862935999421314092e-20 8.580000000000001137e+01 3.540658761157683214e-20 2.573173033208707617e-20 3.711699215949246066e-21 3.350145185224344069e-23 1.124815277645996189e-20 5.337489922567734092e-22 9.624331405055950927e-22 1.859886168600314369e-21 1.752436137436389955e-21 4.531031421026521501e-22 4.479787658629209475e-22 2.369074947267098802e-21 1.148799293860726428e-22 2.856910561483159819e-20 8.590000000000000568e+01 3.558522454520705488e-20 2.573309725025624329e-20 3.699167909202233129e-21 3.332026666705286401e-23 1.124149794986061050e-20 5.321393648279403083e-22 9.602868772341891110e-22 1.857810310021840684e-21 1.731428267909554124e-21 8.602675465935457128e-22 4.564731222391201788e-22 2.681452527432409253e-21 1.094831124056248941e-22 2.860163897516119315e-20 8.600000000000000000e+01 3.669225524636532986e-20 2.573446731461263884e-20 3.685823458505835684e-21 3.313934814852915897e-23 1.123523969829776119e-20 5.305297684110917997e-22 9.581406139627833174e-22 1.855737532636060418e-21 1.800993646350755274e-21 7.964959485442465890e-22 4.649413174816886323e-22 3.623646818041634832e-21 1.040862954251771690e-22 2.870468382420911473e-20 8.610000000000000853e+01 3.676764645669689998e-20 2.573584052465379972e-20 3.666846632189121833e-21 3.296082963000542969e-23 1.122898272719916738e-20 5.289202032893521867e-22 9.559943506913771476e-22 1.853721895145864920e-21 1.584739303054495340e-21 9.072397909878499343e-22 4.454130128411551257e-22 3.152392818753097988e-21 9.868947844472867971e-23 2.863530257267886123e-20 8.620000000000000284e+01 3.566119965706415199e-20 2.573721687987620961e-20 3.646752051855070529e-21 3.278231111148181207e-23 1.122273687503025520e-20 5.273106697492977759e-22 9.538480874199711659e-22 1.851805738139114188e-21 2.195064128522400571e-21 9.311357476380419763e-22 4.368098989996777053e-22 2.555286986875701248e-21 9.329266146428094278e-23 2.861267929443849989e-20 8.630000000000001137e+01 3.258489657896416894e-20 2.573859637977530495e-20 3.683209392203834441e-21 3.260505977896347513e-23 1.121650414583323146e-20 5.257011680810082237e-22 9.517018241485649961e-22 1.849876370213762067e-21 1.620846429195127590e-21 7.443030682641070973e-22 4.506876142656242640e-22 1.693729416872560788e-21 8.789584448383245353e-23 2.850819598963909608e-20 8.640000000000000568e+01 3.470241278072553188e-20 2.573997902384548702e-20 3.774606398589634372e-21 3.242970922545293874e-23 1.121027166641818120e-20 5.240916985781214546e-22 9.495555608771592025e-22 1.847949587367807459e-21 1.615858260111000335e-21 1.128592278660412021e-21 4.498863869487668546e-22 2.642057432628051280e-21 8.249902750338472836e-23 2.860299025379356003e-20 8.650000000000000000e+01 3.583160088812105986e-20 2.574136481158010381e-20 3.864972721365211363e-21 3.225435867194257867e-23 1.120403930171377839e-20 5.224822615378867939e-22 9.474092976057534089e-22 1.846050937465368999e-21 1.653379783738285405e-21 8.586410678456347112e-22 4.679095895308402010e-22 3.338764020875091955e-21 7.710221052293699143e-23 2.867941854687570973e-20 8.660000000000000853e+01 3.415765610632896845e-20 2.574275374247146215e-20 3.943228695061534727e-21 3.208127941211570697e-23 1.119780720488171736e-20 5.208728572612214856e-22 9.452630343343472391e-22 1.844158761149584061e-21 1.701679005503202359e-21 1.471317552775446547e-21 4.634986443960364805e-22 2.160518467255650346e-21 7.170539354248850218e-23 2.860322341887638315e-20 8.670000000000000284e+01 3.427476025246620587e-20 2.574414581601083967e-20 4.021008790814177349e-21 3.190922058858152944e-23 1.119147434452391303e-20 5.192634860527684324e-22 9.431167710629412574e-22 1.842269254223880622e-21 2.016112568535937090e-21 7.834525774787132258e-22 4.658103001649411180e-22 2.442971057251349675e-21 6.635760421573177240e-23 2.862866971228852483e-20 8.680000000000001137e+01 3.430834869825596814e-20 2.574554103168845777e-20 4.114945847383645940e-21 3.173716176504746358e-23 1.118488201979777786e-20 5.176541482209511149e-22 9.409705077915350876e-22 1.840382424910186775e-21 2.095114765857094113e-21 1.175455248166218857e-21 4.698083889937080081e-22 2.355118371828305277e-21 6.126341400011068938e-23 2.865224093793100204e-20 8.690000000000000568e+01 3.353064257933554763e-20 2.574693938899349362e-20 4.225003125176833177e-21 3.156813040326733972e-23 1.117829123231140176e-20 5.160448440780351874e-22 9.388242445201292940e-22 1.838498281452508843e-21 1.838254965133838457e-21 1.020330438062192215e-21 4.629544888700695950e-22 2.598886257851450401e-21 5.616922378449031165e-23 2.866409682939579633e-20 8.700000000000000000e+01 3.668034801707433842e-20 2.574834088741410727e-20 4.304272439719585684e-21 3.139919267432509196e-23 1.117197791315942996e-20 5.144355739401865949e-22 9.366779812487233123e-22 1.836616832116921970e-21 1.770004392138115446e-21 7.414430573575296994e-22 4.593625418505184090e-22 2.822192400392431088e-21 5.107503356886994568e-23 2.868264480454642307e-20 8.710000000000000853e+01 3.565187287663623356e-20 2.574974552643740551e-20 4.173887943574686073e-21 3.123081758274552153e-23 1.116579505555128654e-20 5.128263381275328859e-22 9.345317179773171425e-22 1.834738085191564863e-21 1.490261991031780600e-21 8.244445582516480778e-22 4.709130891096470373e-22 2.157936497006075990e-21 4.598084335324885091e-23 2.859074058129105376e-20 8.720000000000000284e+01 3.276884824823142163e-20 2.575115330554945694e-20 4.012135133956607985e-21 3.106422417614766767e-23 1.115961347126948997e-20 5.112171369642265018e-22 9.323854547059113489e-22 1.832862048986628878e-21 1.696282058409457655e-21 1.001847979234649372e-21 4.674422619617621723e-22 2.162532994642943122e-21 4.088665313762848494e-23 2.858364789063603273e-20 8.730000000000001137e+01 3.583627502808697533e-20 2.575256422423529499e-20 3.873248992787965909e-21 3.089763076954997837e-23 1.115345373924291229e-20 5.096079707785062786e-22 9.302391914345051791e-22 1.830988731834349367e-21 1.623802733204159577e-21 1.606406716827434010e-21 4.827904207419126848e-22 2.076130998028795899e-21 3.579246292200739016e-23 2.858035404437372421e-20 8.740000000000000568e+01 3.427601465931927204e-20 2.575397828197892992e-20 3.758293695325939643e-21 3.073291636395130515e-23 1.114729527426842902e-20 5.079988399027632744e-22 9.280929281630991974e-22 1.829118142088995152e-21 1.633703440644159761e-21 1.061675905243489835e-21 4.565928928545269925e-22 2.255659943494890210e-21 3.069827270638702419e-23 2.855195197651816511e-20 8.750000000000000000e+01 3.594461428493410395e-20 2.575539547826331575e-20 3.651804123892477888e-21 3.057000727303798186e-23 1.114113802330569928e-20 5.063897446736064091e-22 9.259466648916934038e-22 1.827250288126855728e-21 1.544979502768564030e-21 1.078714385686912354e-21 4.643135415254173015e-22 1.967982585555765195e-21 2.560408249076665234e-23 2.851130295999657286e-20 8.760000000000000853e+01 3.501999951721695006e-20 2.575681581257039236e-20 3.583362272090875632e-21 3.040709818212471733e-23 1.113498087419656157e-20 5.047806854319281040e-22 9.238004016202872340e-22 1.825385178346229985e-21 1.729735628504818355e-21 9.679814334916828984e-22 4.743575595617140324e-22 2.394640657353833447e-21 2.050989227514555756e-23 2.854070294221498189e-20 8.770000000000000284e+01 3.410272948305949148e-20 2.575823928438105543e-20 3.529138325329142884e-21 3.024606836393874808e-23 1.112882336363575753e-20 5.031716625229747176e-22 9.216541383488814404e-22 1.823522821167413039e-21 1.711734148282515068e-21 8.132756447929217270e-22 4.771664034553676331e-22 1.873483891856688029e-21 1.618821475321764801e-23 2.848772611113696232e-20 8.780000000000001137e+01 3.425172358864650491e-20 2.575966589317517448e-20 3.447773693752856673e-21 3.008563200029837072e-23 1.112270417702879252e-20 5.015626762964144418e-22 9.195078750774752706e-22 1.821639000943445848e-21 1.460309364773083379e-21 9.542346074790106720e-22 4.796420138466922637e-22 2.184520459633668953e-21 1.784731624512378053e-23 2.848901514584684308e-20 8.790000000000000568e+01 3.460940203720154343e-20 2.576109563843158685e-20 3.336314649299969547e-21 2.992522888116085832e-23 1.111659296402171828e-20 4.999537271064089602e-22 9.173616118060692889e-22 1.819752934462649530e-21 1.756975157912581288e-21 1.266876618931909370e-21 4.721360813773437871e-22 1.859089420265216958e-21 1.950641773702967500e-23 2.848015150771662541e-20 8.800000000000000000e+01 3.442641147808213833e-20 2.576252851962808866e-20 3.260101447868353936e-21 2.976811696779951301e-23 1.111048285014970186e-20 4.983448153116853887e-22 9.152153485346634953e-22 1.817875143141080508e-21 1.709989146629132180e-21 1.386854174394813393e-21 4.661549453657173081e-22 2.307150170760013755e-21 2.116551922893557241e-23 2.850541364214613338e-20 8.810000000000000853e+01 3.202159485711426799e-20 2.576396453624146495e-20 3.362553846093391309e-21 2.961100505443824998e-23 1.110437283752239472e-20 4.967359412756098137e-22 9.130690852632573255e-22 1.816023802307071551e-21 1.905020004777291092e-21 8.090205975537843239e-22 4.719454413571685886e-22 3.170994919833605938e-21 2.282462072084170199e-23 2.858910757455857802e-20 8.820000000000000284e+01 3.296176546549134867e-20 2.576540368774747456e-20 3.503847078999703743e-21 2.945444765371238848e-23 1.109826321357958086e-20 4.951271053662630886e-22 9.109228219918513438e-22 1.814175256464299448e-21 1.931091454639248074e-21 5.557475734545134661e-22 4.804592487531005051e-22 2.202397711670698432e-21 2.448372221274759940e-23 2.850949691526609424e-20 8.830000000000001137e+01 3.222357139907852703e-20 2.576684597362082312e-20 3.492686382476295212e-21 2.929964620966528380e-23 1.109215459753415876e-20 4.935183079565168175e-22 9.087765587204451740e-22 1.812329514165296599e-21 1.786616543894770149e-21 7.982569897471300009e-22 4.704230790410891536e-22 2.355050763826303759e-21 2.614282370465372898e-23 2.851521336793233911e-20 8.840000000000000568e+01 3.325470783081759873e-20 2.576829139333521415e-20 3.339381633661191322e-21 2.914484476561827316e-23 1.108604607778016176e-20 4.919095494241115962e-22 9.066302954490393804e-22 1.810486583984476525e-21 1.476529499110930785e-21 8.397023452625758350e-22 4.722367129674729227e-22 2.233646930376356217e-21 2.780192519655962345e-23 2.846923939475763006e-20 8.850000000000000000e+01 3.144785181406829604e-20 2.576973994636332202e-20 3.199453894249634995e-21 2.899138705063133526e-23 1.107993746553554736e-20 4.903008301517364754e-22 9.044840321776333987e-22 1.808646474518106785e-21 1.700717178503801819e-21 2.255997039001305126e-21 4.742334582287138078e-22 2.573924171310391384e-21 2.946102668846551793e-23 2.856999050979045394e-20 8.860000000000000853e+01 3.202994320693608110e-20 2.577119163217678290e-20 3.124622138901295474e-21 2.883944460458458843e-23 1.107352835390718793e-20 4.886921505271098350e-22 9.023377689062272289e-22 1.806830871047571692e-21 1.453650372603708026e-21 1.240271060215789623e-21 4.839403568437650024e-22 1.796252912650789511e-21 3.112012818037165338e-23 2.842485141212774031e-20 8.870000000000000284e+01 3.324675557116769108e-20 2.577264645024622485e-20 3.059885881530382606e-21 2.868750215853788275e-23 1.106708963011980475e-20 4.870835109430634553e-22 9.001915056348214353e-22 1.805158882066988170e-21 1.970689920476347025e-21 1.082533961448388627e-21 5.001909639798622718e-22 2.218180885529943728e-21 3.277922967227754198e-23 2.847115710071949912e-20 8.880000000000001137e+01 3.468327994259446744e-20 2.577410440004124977e-20 3.064289522550212700e-21 2.853741935509968468e-23 1.106075147617010925e-20 4.854749117976245195e-22 8.980452423634152655e-22 1.803489256729668228e-21 1.634725272272536989e-21 1.275375001737349932e-21 4.973223466574778965e-22 2.277769086232541987e-21 3.717145926712005234e-23 2.846165774345415669e-20 8.890000000000000568e+01 3.347337237363684829e-20 2.577556548103043340e-20 3.141351276642640994e-21 2.838817204326832046e-23 1.105471243871548217e-20 4.838663534941046692e-22 8.958989790920094719e-22 1.801822001606292388e-21 1.701491627421826693e-21 7.760404080019083301e-22 4.859831892999730123e-22 2.444282764874892407e-21 4.170659608171610482e-23 2.846837562390152345e-20 8.900000000000000000e+01 3.466092749735351146e-20 2.577702969268132834e-20 3.211739865671142745e-21 2.823892473143695624e-23 1.104867349466144580e-20 4.822578364411847340e-22 8.937527158206034901e-22 1.800157123282537846e-21 1.758631952940514442e-21 7.084907618876575649e-22 4.806217339021061787e-22 2.460681458024926390e-21 4.624173289631215729e-23 2.847804913735107964e-20 8.910000000000000853e+01 3.545507759547987162e-20 2.577850223664394340e-20 3.136509181295428673e-21 2.809161290347661206e-23 1.104263464416123796e-20 4.806728508280224528e-22 8.916320582377194777e-22 1.798477676447032568e-21 1.590664510761759255e-21 8.659784425821580178e-22 4.728404856967442199e-22 2.362289390539494363e-21 5.077686971090885041e-23 2.845446735278157674e-20 8.920000000000000284e+01 3.597605777681419146e-20 2.578002900325425213e-20 3.047141181658792493e-21 2.794451612927978247e-23 1.103659588736842599e-20 4.793192582419509649e-22 8.897636046058209702e-22 1.796788301679642507e-21 1.384748973433790454e-21 1.208589503498520519e-21 4.775066144945221409e-22 2.271063234843075524e-21 5.531200652550490877e-23 2.843798669737551897e-20 8.930000000000001137e+01 3.705021499718714708e-20 2.578155863158635130e-20 2.965747711023189101e-21 2.779776939526202473e-23 1.103055726437023960e-20 4.779656855370725146e-22 8.878951509739222747e-22 1.795101269826293810e-21 1.498190728534635487e-21 1.523913935542465958e-21 4.804047292597591225e-22 4.552742094084496366e-21 5.984714334010160188e-23 2.872153040672140139e-20 8.940000000000000568e+01 3.570768771030957193e-20 2.578309112113090165e-20 2.892546998624342055e-21 2.765385480451150809e-23 1.102453938870845256e-20 4.766121328827745211e-22 8.860266973420237673e-22 1.793443257431384388e-21 1.563598890783593835e-21 4.168896704705582171e-22 4.798039345879161241e-22 2.481081887532745610e-21 6.438228015469764848e-23 2.842381489587192190e-20 8.950000000000000000e+01 3.496950917238375286e-20 2.578462647137773938e-20 2.853740215293672406e-21 2.750994021376101496e-23 1.101852361649443888e-20 4.752586004503710861e-22 8.841582437101252599e-22 1.791790290227725275e-21 1.619016032910884575e-21 1.134805352051299534e-21 4.906781420415736789e-22 1.965837950504968554e-21 6.891741696929370683e-23 2.840134791782324086e-20 8.960000000000000853e+01 3.586709701911476386e-20 2.578616468181588219e-20 3.076954632189475492e-21 2.736681702151132798e-23 1.101251343282733178e-20 4.739050884131306412e-22 8.822897900782265643e-22 1.790139739624199988e-21 1.427591652922926252e-21 1.496901476725800919e-21 4.993219578638577685e-22 1.363392416343933082e-21 7.345255378389039995e-23 2.839489478736917241e-20 8.970000000000000284e+01 3.541382482013889181e-20 2.578770575193349914e-20 3.332008772270684779e-21 2.722554042576359256e-23 1.100652133610930659e-20 4.725515969463050060e-22 8.804213364463280569e-22 1.788491612311453044e-21 1.554859739945751112e-21 1.019123631202679933e-21 4.905598319751129687e-22 2.078440531127642279e-21 7.798769059848645831e-23 2.845122669419502601e-20 8.980000000000001137e+01 3.514790177058778393e-20 2.578924968121794679e-20 3.469821016575502841e-21 2.708426383001584538e-23 1.100052932675109504e-20 4.711981262271560015e-22 8.785528828144293614e-22 1.786845914994974040e-21 1.499488026182532213e-21 8.641363742791266922e-22 4.959901558881161533e-22 1.960202976520184236e-21 8.235047471499685162e-23 2.845021119004078879e-20 8.990000000000000568e+01 3.204034061097611180e-20 2.579079646915573312e-20 3.493833761663379971e-21 2.694394042575754544e-23 1.099473798864396896e-20 4.698446764349862009e-22 8.766844291825308539e-22 1.785202654395072081e-21 1.587442015036704681e-21 8.528525439958949638e-22 4.824257429239491581e-22 1.861672272441366150e-21 8.662776006775083887e-23 2.844972261089985931e-20 9.000000000000000000e+01 3.486039993502834911e-20 2.579234611523255958e-20 3.497562411467000247e-21 2.680464964561277072e-23 1.098911760787311823e-20 4.684912477511664832e-22 8.748159755506323465e-22 1.783561837246855460e-21 1.609350435367398012e-21 1.649145332144687979e-21 4.916876505680220484e-22 1.870013776894305107e-21 9.090504542050482613e-23 2.848617254486254407e-20 9.015001386577819176e+01 3.619457925158044556e-20 2.579467615789433418e-20 3.201894990807744610e-21 2.659611249745154006e-23 1.098057184126720327e-20 4.664609570480265056e-22 8.720130360271483198e-22 1.781104980934174072e-21 1.629118755563560847e-21 1.276932331783030604e-21 4.988687392838889976e-22 1.617780097450961731e-21 9.732156652853581622e-23 2.841657228624749011e-20 9.030000000000001137e+01 3.472188502213759146e-20 2.579701219714181212e-20 2.982498465663999285e-21 2.639111378113282316e-23 1.097165216888365947e-20 4.644310901951900776e-22 8.692106146549364480e-22 1.778654114084850548e-21 1.702551351286074456e-21 1.112125153976251316e-21 4.906173846936190034e-22 1.590436388135904017e-21 1.037369014787679987e-22 2.838679754956903990e-20 9.040000000000000568e+01 3.510885217814750632e-20 2.579857327061520273e-20 2.989216766104680042e-21 2.625443533590035242e-23 1.096570527741819632e-20 4.630777478009247957e-22 8.673421610230379406e-22 1.777019058514776868e-21 1.693540451256502628e-21 1.216919456802448215e-21 4.845965136532152104e-22 1.440768804486334149e-21 1.080141868315219977e-22 2.838212446554565080e-20 9.050000000000000000e+01 3.270927254732041721e-20 2.580013719964371258e-20 3.031611733262424126e-21 2.611979295795505903e-23 1.095975906954172685e-20 4.617244274539687174e-22 8.654737073911394331e-22 1.775361387895994597e-21 1.517606400752195185e-21 9.519867682924305057e-22 4.788784411259439998e-22 1.574179179107616918e-21 1.122914721842759967e-22 2.837249151183324954e-20 9.060000000000000853e+01 3.421658377308064767e-20 2.580170398370808087e-20 3.177309487085224119e-21 2.598556760583963759e-23 1.095381306678029171e-20 4.603711293487540624e-22 8.636052537592407376e-22 1.773706148256157809e-21 1.453006046330199351e-21 1.174267552071464993e-21 4.776912146334044321e-22 1.637368251254153107e-21 1.165687575370305834e-22 2.839589040546602007e-20 9.070000000000000284e+01 3.397728887452524549e-20 2.580327362228824631e-20 3.335598076064304623e-21 2.585134225372428963e-23 1.094787647292834363e-20 4.590178536820037602e-22 8.617368001273422302e-22 1.772065911592911371e-21 1.363237147688534068e-21 1.173259448875293426e-21 4.949826135142553478e-22 1.433720083449604031e-21 1.208460428897845589e-22 2.839780687120926206e-20 9.080000000000001137e+01 3.413994825446008810e-20 2.580484611486329603e-20 3.448059381705554178e-21 2.571938947388473247e-23 1.094195194222940079e-20 4.576646006527635167e-22 8.598683464954435347e-22 1.770444813781901474e-21 1.364269914702736824e-21 7.476007552984161311e-22 4.870819398877083942e-22 1.489689551911235156e-21 1.250602088127934183e-22 2.839862107085114736e-20 9.090000000000000568e+01 3.667069088613143801e-20 2.580642146091151968e-20 3.518162235056766630e-21 2.558745964932071216e-23 1.093602749225668275e-20 4.563113704624374559e-22 8.579998928635450272e-22 1.768826220679699289e-21 1.438792406823443033e-21 1.022003720594341912e-21 4.960401879199619986e-22 1.773138272784216469e-21 1.291013990656905328e-22 2.843484998747692709e-20 9.100000000000000000e+01 3.303305567577755859e-20 2.580799965991038236e-20 3.588954657893212309e-21 2.545586853166390511e-23 1.093011866518204228e-20 4.549581633148218798e-22 8.561314392316467079e-22 1.767210139168516543e-21 1.491621077554968995e-21 1.069090451992917464e-21 5.032096664750922737e-22 1.327138779185040943e-21 1.331425893185876472e-22 2.842296071412034847e-20 9.110000000000000853e+01 3.419184065465779296e-20 2.580958071133652164e-20 3.629841088221684733e-21 2.532635804215088754e-23 1.092421770634522343e-20 4.536049794161418498e-22 8.542629855997478243e-22 1.765596576145062098e-21 1.600773625295713940e-21 9.104317862387643963e-22 4.984136838140178791e-22 2.145521954526141516e-21 1.371837795714853494e-22 2.847743129251947192e-20 9.120000000000000284e+01 3.595835601897535689e-20 2.581116461466578064e-20 3.663439025271036787e-21 2.519684755263789347e-23 1.091831682471831615e-20 4.522518189750870156e-22 8.523945319678495049e-22 1.764011026752415973e-21 1.302355285500927863e-21 7.936252482433646160e-22 4.891919467099982732e-22 3.428430420669351418e-21 1.412249698243824638e-22 2.858722587447454464e-20 9.130000000000001137e+01 3.485370211837099322e-20 2.581275136937315086e-20 3.531636721994826237e-21 2.506800975628546856e-23 1.091243685913567980e-20 4.508986822028482911e-22 8.505260783359506213e-22 1.762529947388332931e-21 1.525519333053366184e-21 8.574430532586970435e-22 4.985688955304877815e-22 1.805758545386068968e-21 1.452661600772801425e-22 2.843375755682189673e-20 9.140000000000000568e+01 3.222408972344113809e-20 2.581434097493284139e-20 3.232908336350483223e-21 2.494090174234576491e-23 1.090655712296101633e-20 4.495455693131561279e-22 8.486576247040523020e-22 1.761051019966210613e-21 1.413421182609556029e-21 1.262513986828845515e-21 4.932075013069209046e-22 1.827250842330980856e-21 1.493073503301772570e-22 2.840783714497654837e-20 9.150000000000000000e+01 3.369218470964434166e-20 2.581593343081822173e-20 2.972094974192528182e-21 2.481379372840608182e-23 1.090067746619937480e-20 4.481924805223177555e-22 8.467891710721537945e-22 1.759574249912189625e-21 1.282922531549328745e-21 8.303278640941113377e-22 4.987103889292111620e-22 2.057575546203397781e-21 1.533485405830743949e-22 2.837210534779588972e-20 9.160000000000000853e+01 3.416440317448137530e-20 2.581752873650186693e-20 3.067611011327230153e-21 2.468760694462517401e-23 1.089479817094415769e-20 4.468394160492563954e-22 8.449207174402550050e-22 1.758099642662713543e-21 1.235488055610835081e-21 1.307102585008150113e-21 4.973135449186201911e-22 2.632217881102871223e-21 1.573897308359720736e-22 2.844454861731344614e-20 9.170000000000000284e+01 3.481602142356031266e-20 2.581912689145551849e-20 3.201506653808502288e-21 2.456274583351172124e-23 1.088891935897584248e-20 4.454863761155519804e-22 8.430522638083565916e-22 1.756627203664505971e-21 1.231169629604671143e-21 1.050115135006925928e-21 4.851234184396988483e-22 2.540093724706931949e-21 1.614309210888691881e-22 2.843893567008132415e-20 9.180000000000001137e+01 3.485885735854736158e-20 2.582072789515012647e-20 3.350425002038957384e-21 2.443788472239831256e-23 1.088324279251508240e-20 4.441333609454794287e-22 8.411838101764578020e-22 1.755142454175612536e-21 1.322312540899222031e-21 1.438921828084267942e-21 4.941707418208304933e-22 1.887504182364879027e-21 1.654721113417668903e-22 2.842568453992401883e-20 9.190000000000000568e+01 3.317154898011552388e-20 2.582233174705581636e-20 3.514590585666671926e-21 2.431420622854755652e-23 1.087776883323504376e-20 4.427803707660517139e-22 8.393153565445593886e-22 1.753645363488901630e-21 1.300111871635761069e-21 9.217489522884122423e-22 5.085949461138145484e-22 1.857895011465861592e-21 1.694073157089817783e-22 2.842052849854154634e-20 9.200000000000000000e+01 3.221049140342698396e-20 2.582393844664189819e-20 3.655975253094339164e-21 2.419157647075985341e-23 1.087229527015525795e-20 4.414274058070599261e-22 8.374469029126608812e-22 1.752150409210023320e-21 1.371926911028264223e-21 5.359472119232905009e-22 4.934451407930922352e-22 1.643830839104686538e-21 1.733063797047694942e-22 2.841761203982968267e-20 9.210000000000000853e+01 3.358497880151828208e-20 2.582554799337688750e-20 3.609686861669500488e-21 2.406894671297219144e-23 1.086655386139425644e-20 4.400744663011174702e-22 8.355784492807621856e-22 1.750679086701755929e-21 1.529555060440858722e-21 1.105696621623346242e-21 4.872537317619538150e-22 2.621844209910462624e-21 1.772054437005577978e-22 2.850847353702284807e-20 9.220000000000000284e+01 3.561088495865258025e-20 2.582716038672847833e-20 3.540894745087368936e-21 2.394746851227799193e-23 1.086071839258270643e-20 4.387215524837025718e-22 8.337099956488636782e-22 1.749217504049119065e-21 1.436109917510791127e-21 1.300751090917011624e-21 4.906695965503542305e-22 1.839225042473977965e-21 1.811045076963455137e-22 2.844106022819810411e-20 9.230000000000001137e+01 3.413260388175464618e-20 2.582877562616355521e-20 3.522442431504318433e-21 2.382663806244882685e-23 1.085488299844450540e-20 4.373686645932019118e-22 8.318415420169649827e-22 1.747758122531681563e-21 1.284948852054450975e-21 8.336719172768252630e-22 4.994032021145540947e-22 1.843724017253813371e-21 1.850035716921338173e-22 2.841354015875008811e-20 9.240000000000000568e+01 3.103762301701845592e-20 2.583039371114821124e-20 3.555812883093033281e-21 2.370580761261976756e-23 1.084906817408997181e-20 4.360158028709571758e-22 8.299730883850664753e-22 1.746300947667901899e-21 1.238405685755511582e-21 1.881712333862817959e-21 4.995453397832156203e-22 1.703122014428877566e-21 1.889026356879215332e-22 2.845601453383289487e-20 9.250000000000000000e+01 3.371518884353736555e-20 2.583201464114771197e-20 3.591042199351024786e-21 2.358683711356300041e-23 1.084325444888187257e-20 4.346629675613099109e-22 8.281046347531679678e-22 1.744845984986313195e-21 1.613398827372480897e-21 1.100530755563928438e-21 5.045356970686331903e-22 1.784726681387318132e-21 1.928016996837092726e-22 2.844249754127167342e-20 9.260000000000000853e+01 3.316468540387379368e-20 2.583363841562652850e-20 3.602422363530381036e-21 2.346848659809700810e-23 1.083744535791294940e-20 4.333101589116473231e-22 8.262361811212692723e-22 1.743393240025498766e-21 1.489362627148106848e-21 7.423011826265816003e-22 5.050333552306736160e-22 2.057360265013849089e-21 1.967007636794975762e-22 2.844311217960592966e-20 9.270000000000000284e+01 3.444927149132435478e-20 2.583526503404832848e-20 3.617340378581253188e-21 2.335013608263109219e-23 1.083165274148709442e-20 4.319573771724521181e-22 8.243677274893707649e-22 1.741942718334061276e-21 1.441878541143944908e-21 9.021337369279477223e-22 5.089702365958847846e-22 1.962483449808593288e-21 2.005998276752852921e-22 2.843967900987847952e-20 9.280000000000001137e+01 3.416799614054021897e-20 2.583689449587596701e-20 3.644765792707838264e-21 2.323328659809299886e-23 1.082586062905747344e-20 4.306046225973482990e-22 8.224992738574720693e-22 1.740494425470594154e-21 1.770654492987557551e-21 6.280941309627890977e-22 5.099152574788014795e-22 1.837833269331852656e-21 2.044988916710735722e-22 2.844520457519946488e-20 9.290000000000000568e+01 3.266459379300564449e-20 2.583852680057150179e-20 3.680809756475709795e-21 2.311672302420787393e-23 1.082022323740140233e-20 4.292518954431530753e-22 8.206308202255735619e-22 1.739048367003652999e-21 1.447318874504439844e-21 8.747025632346473970e-22 5.073754892417025117e-22 1.652158891258219409e-21 2.083789323102156938e-22 2.842583141264350645e-20 9.305001343363686317e+01 3.381404182089774136e-20 2.584098080685488421e-20 3.744534057695212612e-21 2.294296762187453361e-23 1.081207401276761816e-20 4.272226749828596118e-22 8.178278887764499226e-22 1.736883287346691971e-21 1.384611825354947253e-21 5.054105563654202017e-22 5.020815361863868830e-22 1.636512722742095827e-21 2.139486224028029840e-22 2.841999373577441379e-20 9.320000000000000284e+01 3.251866719421452898e-20 2.584344076647402625e-20 3.811468738740999574e-21 2.277199317420857652e-23 1.080371975475874692e-20 4.251938811231279391e-22 8.150254593298779455e-22 1.734704876074700494e-21 1.425310876971766509e-21 6.973769182012386163e-22 5.082844436729589021e-22 1.673844518788644583e-21 2.195173149688047404e-22 2.843610386647668725e-20 9.330000000000001137e+01 3.323811627214912740e-20 2.584508443724568334e-20 3.698514959699805978e-21 2.265800000014528021e-23 1.079796943340283952e-20 4.238412662863535029e-22 8.131570056979791560e-22 1.733238882932833723e-21 1.414307780184602660e-21 8.922329125665832253e-22 5.129509083398222365e-22 1.650954951322819343e-21 2.232301091883347439e-22 2.842400378447855084e-20 9.340000000000000568e+01 3.418788780649583610e-20 2.584677370982766960e-20 3.427474668847732724e-21 2.254550853256664206e-23 1.079221983697918982e-20 4.226945160294185385e-22 8.115210385908431048e-22 1.731775104521628911e-21 1.516200233519642633e-21 6.331516459702699258e-22 4.988031620716355027e-22 1.808557420802099171e-21 2.269429034078642772e-22 2.839688407132074205e-20 9.350000000000000000e+01 3.314824885301718109e-20 2.584846734540740070e-20 3.200216840684896202e-21 2.243301706498806269e-23 1.078647030734240761e-20 4.215560700521012381e-22 8.098944352653956309e-22 1.730338162430104860e-21 1.263511519516200268e-21 1.103873321751008982e-21 4.839500988249126597e-22 1.376372390369316750e-21 2.306556976273937634e-22 2.834709180700304291e-20 9.360000000000000853e+01 3.076317063444499833e-20 2.585016361724303607e-20 3.193990631323861454e-21 2.232067619061604199e-23 1.078072084688245005e-20 4.204176377879394275e-22 8.082678319399479689e-22 1.728907834406673249e-21 1.110381143859159741e-21 8.553372030173170199e-22 4.953596402739385620e-22 1.316636461677929370e-21 2.343684918469237669e-22 2.832798148317847736e-20 9.370000000000000284e+01 3.337752287347607097e-20 2.585186252481563989e-20 3.252717416589615967e-21 2.221033605455983647e-23 1.077499028138311298e-20 4.192792193486357738e-22 8.066412286145004950e-22 1.727479785679200727e-21 1.371185443108149051e-21 1.191515769085409881e-21 5.096203999990658930e-22 1.613324585744947145e-21 2.380812860664533002e-22 2.837304351351295440e-20 9.380000000000001137e+01 3.485681769334072633e-20 2.585356406760559929e-20 3.362007547535257795e-21 2.209999591850368384e-23 1.076961694033980432e-20 4.181408148471075591e-22 8.050146252890528330e-22 1.726054021905005319e-21 1.300090243859096785e-21 7.094774975727158648e-22 4.980082393858621320e-22 1.716000009291884388e-21 2.417940802859833037e-22 2.837149776714012186e-20 9.390000000000000568e+01 3.398923027450532266e-20 2.585526824509265437e-20 3.510240767747579153e-21 2.198989830521936551e-23 1.076424376934953150e-20 4.170024243975040776e-22 8.033880219636053591e-22 1.724694517467279116e-21 1.311388524307340015e-21 8.118573322879063673e-22 4.771935090130024987e-22 1.734029823732919474e-21 2.455068745055128370e-22 2.839284605598696592e-20 9.400000000000000000e+01 3.691170597156811167e-20 2.585697505675585613e-20 3.635351893271292857e-21 2.188142372894648103e-23 1.075879563901578113e-20 4.158640481152229514e-22 8.017614186381578852e-22 1.723399239466011308e-21 1.494729147030680855e-21 6.928003853501563746e-22 4.949250474984036499e-22 2.428551181841591915e-21 2.491597298467645580e-22 2.846499699461261801e-20 9.410000000000000853e+01 3.454897818683294782e-20 2.585868450207359655e-20 3.528604127482717975e-21 2.177294915267364358e-23 1.075310785286442373e-20 4.147256861169272459e-22 8.001348153127101292e-22 1.722105872473702877e-21 1.431120939608194122e-21 1.207390388118041119e-21 4.914890949148073225e-22 1.721012936185824260e-21 2.526936919938669627e-22 2.841308634112713036e-20 9.420000000000000284e+01 3.518718748944173570e-20 2.586039658052359651e-20 3.420712943276808667e-21 2.166483243256206085e-23 1.074742018055034668e-20 4.135873385205633840e-22 7.985082119872626552e-22 1.720814420799306102e-21 1.479893048479634193e-21 1.060377677945522039e-21 4.902235354582592814e-22 1.900999069166379660e-21 2.562276541409688503e-22 2.840727061524581446e-20 9.430000000000001137e+01 3.439951867669647130e-20 2.586211129158291790e-20 3.449077337160779894e-21 2.155834594607392911e-23 1.074186987730738084e-20 4.124490054453778386e-22 7.968816086618149932e-22 1.719524888758328567e-21 1.498626767025101712e-21 1.056565689792961793e-21 4.835518045386304388e-22 1.877020566484928542e-21 2.597616162880712550e-22 2.840918489464743770e-20 9.440000000000000568e+01 3.302998274473822398e-20 2.586382863472795152e-20 3.588642832861932974e-21 2.145185945958585027e-23 1.073651690044883193e-20 4.113106870119362221e-22 7.952550053363675193e-22 1.718237280672807215e-21 1.345408369681606138e-21 1.510399364449034241e-21 4.824093193594725584e-22 1.529440505656053475e-21 2.632955784351731425e-22 2.841787909426892534e-20 9.450000000000000000e+01 3.430750045371197161e-20 2.586554860943442914e-20 3.714134890354767596e-21 2.134577777790257639e-23 1.073116403794157300e-20 4.101723833421406372e-22 7.936284020109200454e-22 1.716951600871287650e-21 1.250417016548731232e-21 1.262770467676223345e-21 5.020932471763311309e-22 1.414210589273753906e-21 2.668295405822750771e-22 2.841139154492764637e-20 9.460000000000000853e+01 3.442497262649727789e-20 2.586727121517741148e-20 3.769867196047890489e-21 2.124113131325454627e-23 1.072562588833183279e-20 4.090340945592484374e-22 7.920017986854723834e-22 1.715650863898540148e-21 1.435252250963424056e-21 1.217313544469643657e-21 4.909913920646978157e-22 1.956823435507576129e-21 2.703635027293774348e-22 2.845681434247010930e-20 9.475001319261123456e+01 3.204870792973203701e-20 2.586986028378609949e-20 3.862972887779151284e-21 2.108414781068131903e-23 1.071712464808609057e-20 4.073265394048299131e-22 7.895616791058481133e-22 1.713685442120880546e-21 1.405138602296127466e-21 1.350738082175624423e-21 4.868210240798362443e-22 2.126083616354252848e-21 2.756649121719175403e-22 2.848486618369318380e-20 9.490000000000000568e+01 3.405918435016802485e-20 2.587245481336607836e-20 3.927749567940278763e-21 2.092964429542069935e-23 1.070890390468929700e-20 4.056193187852977365e-22 7.871219887091296796e-22 1.711746287262620939e-21 1.187325806140019176e-21 1.557760885005379950e-21 4.854392235587757826e-22 1.949022355372386598e-21 2.809653891706836146e-22 2.848080057710886202e-20 9.500000000000000000e+01 3.424939817168711959e-20 2.587418793799247599e-20 3.965010513361222363e-21 2.082695973166084283e-23 1.070360833181725000e-20 4.044810908103698260e-22 7.854953853836822056e-22 1.710470252891940294e-21 1.430456713201160099e-21 9.372639681237285665e-22 4.801615463457329649e-22 1.936365184325579699e-21 2.844993513177855491e-22 2.846848374285102477e-20 9.510000000000000853e+01 3.395789832784853030e-20 2.587592369102076034e-20 3.988945575772513956e-21 2.072476521750703815e-23 1.069831281428827750e-20 4.033428783596351900e-22 7.838687820582345436e-22 1.709196172914367707e-21 1.284815101303825408e-21 1.093313122227693659e-21 4.844331954797515347e-22 2.454165509005460374e-21 2.879580704557759689e-22 2.850990239733145334e-20 9.520000000000000284e+01 3.569160057671047786e-20 2.587766207192204095e-20 4.019384410795346946e-21 2.062389565228822709e-23 1.069270175137270613e-20 4.022046815648914307e-22 7.822421787327870697e-22 1.707924051703727322e-21 1.493178799501534542e-21 1.319847843605398920e-21 4.824646494822510404e-22 2.212388968734157816e-21 2.913223401056088452e-22 2.851346531882856446e-20 9.530000000000001137e+01 3.427101497814700507e-20 2.587940308016675028e-20 4.055556766651520998e-21 2.052302608706940720e-23 1.068705568312845409e-20 4.010665005594298743e-22 7.806155754073393137e-22 1.706653893640148821e-21 1.400856859092154627e-21 6.222974751595673089e-22 4.794610814674789006e-22 1.916270087842010272e-21 2.946866097554422388e-22 2.846798158691105011e-20 9.540000000000000568e+01 3.170924913979101308e-20 2.588114671522467681e-20 4.095543195048590696e-21 2.042256856198438472e-23 1.068142828660925351e-20 3.999283354780579527e-22 7.789889720818918398e-22 1.705385703110044107e-21 1.451606467924029498e-21 1.562806421885125458e-21 4.753493115249589144e-22 2.680606721029553877e-21 2.980508794052751152e-22 2.857316280195118745e-20 9.550000000000000000e+01 3.183356998340860074e-20 2.588289297656492592e-20 4.121275364385424752e-21 2.032317056867198791e-23 1.067615195505092478e-20 3.987901864571197511e-22 7.773623687564443659e-22 1.704119484506074195e-21 1.439714893993695511e-21 9.193560546016143302e-22 4.782999570754781588e-22 2.382163571275924715e-21 3.014151490551079916e-22 2.852138429142426296e-20 9.560000000000000853e+01 3.116578138029898739e-20 2.588464186365598908e-20 4.028133938026578152e-21 2.022377257535957346e-23 1.067087568345829513e-20 3.976520536345182481e-22 7.757357654309967039e-22 1.702855242227127402e-21 1.452850767034553107e-21 7.654169100474401631e-22 4.794190863898195278e-22 2.297208114255738262e-21 3.047794187049413382e-22 2.849674876309303850e-20 9.570000000000000284e+01 2.939120551142913919e-20 2.588639337596566565e-20 3.931774650754580796e-21 2.012495149512399973e-23 1.066554057739397063e-20 3.965139371497384028e-22 7.741091621055492300e-22 1.701592980678288122e-21 1.373053100949423147e-21 1.099147631197249632e-21 4.822022734924771364e-22 1.655864012313877202e-21 3.081436883547742145e-22 2.844526356418714242e-20 9.580000000000001137e+01 2.992820160816211481e-20 2.588814751296111101e-20 3.868301874232358052e-21 2.002754285724892501e-23 1.065995423309005820e-20 3.953758371438685014e-22 7.724825587801015680e-22 1.700332704270809743e-21 1.306741051879858057e-21 1.047674145455971181e-21 4.837201672421918579e-22 2.815006544458322352e-21 3.115079580046075611e-22 2.852191484812452834e-20 9.590000000000000568e+01 3.464799636708998872e-20 2.588990427410883352e-20 3.833545820127032486e-21 1.993013421937386498e-23 1.065436794564537552e-20 3.942377537596245608e-22 7.708559554546540940e-22 1.699074417422086059e-21 1.334106761116832464e-21 8.680027044111147009e-22 4.764170895342892543e-22 3.025006071237681252e-21 3.148722276544404375e-22 2.853323878627102792e-20 9.605001301405430070e+01 3.835694857612040456e-20 2.589254456425598739e-20 3.678677762604768517e-21 1.978539682639792756e-23 1.064626910588072469e-20 3.925305120586584418e-22 7.684158387794427706e-22 1.697167310533572488e-21 1.376265138103716284e-21 1.688459295713009526e-21 4.817613339558383150e-22 2.832388797059125342e-21 3.199190699570689105e-22 2.853115420780437309e-20 9.620000000000000284e+01 2.977453139735053631e-20 2.589519029712090145e-20 3.280996193591658449e-21 1.964196556301484754e-23 1.063841127883781151e-20 3.908236047887087453e-22 7.659761454783113902e-22 1.695245160559528138e-21 1.360033923482190718e-21 1.318786660682575127e-21 4.890442622265748105e-22 3.720410040465246976e-21 3.248955064305129685e-22 2.856379488740967723e-20 9.630000000000001137e+01 3.186569216690068314e-20 2.589695754952971402e-20 3.117311596000187423e-21 1.954671523188776732e-23 1.063303159489552184e-20 3.896855893514995958e-22 7.643495421528637282e-22 1.693978436373963397e-21 1.223791039723058562e-21 1.211120474441808845e-21 4.714469676873473778e-22 2.795513880299137683e-21 3.280963294493313547e-22 2.842792144207987827e-20 9.640000000000000568e+01 3.175422049567038821e-20 2.589872742341353543e-20 3.048804306448781277e-21 1.945254304645608611e-23 1.062746569828341110e-20 3.885475912747391509e-22 7.627229388274162543e-22 1.692730102720322087e-21 1.608650376278596988e-21 1.029741267353346883e-21 4.709318138376763343e-22 2.642432202883376693e-21 3.312971524681493177e-22 2.841729846005445542e-20 9.650000000000000000e+01 3.170842408547864705e-20 2.590049991823495901e-20 3.001085019618892192e-21 1.935837086102440784e-23 1.062189985544002344e-20 3.874096107114138626e-22 7.610963355019687803e-22 1.691483785265817042e-21 1.621851117410352213e-21 7.996555329932333612e-22 4.660554883342632650e-22 2.919425064196393883e-21 3.344979754869672806e-22 2.843202418342658283e-20 9.660000000000000853e+01 3.239298233716195091e-20 2.590227503345593408e-20 3.069241992605846932e-21 1.926466315799079260e-23 1.061652081444698304e-20 3.862716478163106641e-22 7.594697321765211184e-22 1.690242723591220261e-21 1.105379952356321106e-21 5.141692698492675658e-22 4.573552013278945746e-22 3.003108550013437635e-21 3.376987985057857138e-22 2.841601686148924761e-20 9.670000000000000284e+01 3.229916696873369054e-20 2.590405276853776903e-20 3.153717686723423192e-21 1.917242631588435931e-23 1.061130092896289735e-20 3.851337027460439121e-22 7.578431288510735504e-22 1.689099098624304145e-21 1.242776635007863638e-21 3.293308351871850999e-22 4.585458936256802955e-22 2.775177169076814313e-21 3.408996215246036768e-22 2.840462476047518933e-20 9.680000000000001137e+01 3.302606444199394537e-20 2.590583312294110416e-20 3.217548320684036414e-21 1.908018947377791132e-23 1.060608109907286492e-20 3.839957756590812478e-22 7.562165255256258884e-22 1.687957193169470416e-21 1.490325667115265826e-21 7.021003416449744744e-22 4.540832889043045199e-22 2.441693976434464609e-21 3.441004445434221100e-22 2.839935077965830745e-20 9.690000000000000568e+01 3.486867469644237200e-20 2.590761609612594783e-20 3.261164690417962172e-21 1.898821578956625019e-23 1.060088458842324895e-20 3.828578667157726078e-22 7.545899222001784145e-22 1.686817010718834998e-21 1.229681621605395564e-21 6.930004253224127786e-22 4.451003773652251800e-22 2.334166541382366184e-21 3.473012675622400730e-22 2.838203043644737395e-20 9.700000000000000000e+01 3.457640814074152901e-20 2.590940168755166743e-20 3.328360146624992118e-21 1.889729473693355130e-23 1.059570097145800644e-20 3.817199760783765555e-22 7.529633188747309406e-22 1.685678554768686162e-21 1.326979997318901704e-21 7.541263305098306502e-22 4.636613081506729247e-22 1.586604913002640958e-21 3.505020905810580360e-22 2.834401560217536966e-20 9.710000000000000853e+01 3.363796149807435111e-20 2.591118989667696832e-20 3.498034529746397023e-21 1.880637368430083772e-23 1.059051740861377268e-20 3.805821039110899975e-22 7.513367155492832786e-22 1.684541828819461390e-21 1.466167713559332001e-21 1.124225946956971975e-21 4.459550979320187204e-22 2.371214182463644884e-21 3.537029135998764221e-22 2.843752135840006447e-20 9.725001285346959889e+01 3.254577728931486642e-20 2.591387734788566076e-20 3.757863357981024468e-21 1.867132190811570145e-23 1.058231592861975365e-20 3.788751844044027066e-22 7.488966014861481083e-22 1.682839845652073062e-21 1.399100347632975620e-21 7.226861524492461452e-22 4.404200578927948932e-22 2.522310309011375511e-21 3.585045595449170052e-22 2.846641845087525433e-20 9.740000000000000568e+01 3.102766776390078895e-20 2.591657022482789091e-20 3.619911246719593958e-21 1.853800000008703879e-23 1.057402712563975322e-20 3.771685999015372579e-22 7.464569055729405747e-22 1.681142066043504378e-21 1.379672094401221194e-21 1.455352957141520792e-21 4.433562912475494730e-22 2.843961315931112797e-21 3.631044142193886435e-22 2.850520178100269297e-20 9.750000000000000000e+01 3.182438737144625156e-20 2.591836889932582322e-20 3.537598975477776792e-21 1.844922875825593212e-23 1.056881508014747860e-20 3.760308032964408911e-22 7.448303022474931008e-22 1.679988640160212884e-21 1.496200780919527848e-21 5.070006357237630279e-22 4.552854515913054271e-22 2.074092026860414376e-21 3.661481914780314627e-22 2.840130370525911615e-20 9.760000000000000853e+01 3.153934762921197836e-20 2.592017018880727304e-20 3.512847865906452678e-21 1.836151633995423188e-23 1.056366733156520062e-20 3.748930260125394822e-22 7.432036989220454388e-22 1.678832081985209430e-21 1.416898355858202106e-21 9.393536887614348879e-22 4.501976801414474008e-22 2.606340478398070444e-21 3.691919687366746580e-22 2.844855143439272539e-20 9.770000000000000284e+01 3.267022608225540794e-20 2.592197409272711193e-20 3.502751578173239338e-21 1.827380392165254633e-23 1.055851963613362984e-20 3.737552682262847014e-22 7.415770955965979649e-22 1.677677236820791611e-21 1.249034451280998286e-21 8.413078781243591078e-22 4.499737255163245945e-22 1.956769394590981469e-21 3.722357459953174301e-22 2.838384715106934822e-20 9.780000000000001137e+01 3.308938300814886618e-20 2.592381004215933777e-20 3.544139670765867007e-21 1.818616623384913814e-23 1.055337203172282478e-20 3.727670037200623448e-22 7.401269362952326848e-22 1.676549809368929739e-21 1.179455069332554755e-21 7.369657558660301579e-22 4.509278714942390723e-22 1.615882786439155761e-21 3.752795232539606254e-22 2.836134496281697871e-20 9.790000000000000568e+01 3.167261320419259388e-20 2.592565415181937884e-20 3.636803944913611947e-21 1.810032207800397802e-23 1.054822538559729060e-20 3.718076382355213697e-22 7.387108784743765730e-22 1.675426993861673075e-21 1.388125597063566537e-21 8.830485278633777149e-22 4.462189617151649023e-22 1.511345732316967185e-21 3.783233005126033975e-22 2.838054502672519753e-20 9.800000000000000000e+01 3.118523749726857964e-20 2.592750072044866399e-20 3.740042579478682447e-21 1.801447792215881496e-23 1.054307878893724030e-20 3.708482821086988707e-22 7.372948206535204611e-22 1.674305940055305329e-21 1.306398919489861295e-21 7.235526343804552148e-22 4.468199261333069483e-22 1.598099420400134891e-21 3.813670777712461697e-22 2.839002812012672987e-20 9.810000000000000853e+01 3.234370391419876874e-20 2.592934974752184467e-20 3.881389370556170745e-21 1.792863376631368129e-23 1.053761937577301875e-20 3.698889354124060962e-22 7.358787628326641612e-22 1.673186651490904868e-21 1.365690901687541973e-21 1.304614866151254085e-21 4.440466751694302762e-22 1.946323799882299767e-21 3.844108550298894120e-22 2.845375636617643987e-20 9.825001272264549357e+01 3.304762370064452005e-20 2.593212813243389823e-20 4.078403264654264629e-21 1.780156325311112269e-23 1.052941507289767470e-20 3.684498111594984650e-22 7.337544959413634674e-22 1.671510894276092054e-21 1.404550566249506328e-21 1.092452596804222338e-21 4.527903454428617761e-22 2.071294838471159572e-21 3.889769081668438025e-22 2.848259890427449808e-20 9.840000000000000568e+01 3.232743619574858728e-20 2.593491157414300490e-20 3.911051424221431371e-21 1.767456103903810259e-23 1.052158021934037635e-20 3.670109526462305872e-22 7.316305893700957316e-22 1.669839412718614191e-21 1.213101837832949690e-21 8.418583189442745243e-22 4.607272280811374354e-22 1.900617866826304970e-21 3.935414795617670135e-22 2.842952870828562083e-20 9.850000000000000000e+01 3.140436109508505085e-20 2.593677042972728031e-20 3.755675940370578293e-21 1.759126601949361226e-23 1.051646878890169381e-20 3.660516444154531623e-22 7.302145315492396198e-22 1.668727220610460448e-21 1.345675471498559179e-21 5.488570397848814097e-22 4.665586782672990105e-22 1.438091022720767162e-21 3.964369991950437981e-22 2.838000134863016820e-20 9.860000000000000853e+01 3.323053132944611244e-20 2.593863174112047213e-20 3.508329608555121052e-21 1.750815922337617033e-23 1.051135881831641051e-20 3.650923459908113601e-22 7.287984737283833198e-22 1.667614537993576587e-21 1.394310265224262367e-21 4.948597747599252775e-22 4.629972470783975526e-22 1.695652056644576453e-21 3.993325188283209589e-22 2.836359282586545115e-20 9.870000000000000284e+01 3.000636615624997194e-20 2.594049550779394270e-20 3.246434808096846312e-21 1.742505242725877835e-23 1.050626469207341219e-20 3.641330574498074037e-22 7.273824159075272080e-22 1.666477476224347522e-21 1.275637303897908825e-21 1.453934943763709915e-21 4.591302925044771726e-22 1.793514195386438381e-21 4.022280384615977435e-22 2.836546899573474387e-20 9.880000000000001137e+01 3.253149109353952500e-20 2.594236172921851868e-20 3.088925320194715720e-21 1.734317677426695520e-23 1.050117102567485737e-20 3.631737788707610494e-22 7.259663580866709081e-22 1.665342166991531238e-21 1.330468713095846276e-21 9.028972104027083390e-22 4.493562120163332488e-22 1.727620567239792971e-21 4.051235580948749513e-22 2.832297409516767217e-20 9.890000000000000568e+01 3.140744605799304510e-20 2.594423040486447003e-20 3.032642811646433929e-21 1.726162838716929715e-23 1.049607956217121845e-20 3.622145103328214352e-22 7.245503002658147962e-22 1.664212030885870758e-21 1.544306393517058862e-21 6.641676416005966312e-22 4.507324370394297599e-22 1.966454190360109285e-21 4.080190777281517359e-22 2.833648450865783302e-20 9.900000000000000000e+01 3.303897288676402407e-20 2.594610153420151602e-20 2.998493997558735186e-21 1.718008000007166849e-23 1.049100315277299821e-20 3.612552519159772839e-22 7.231342424449587784e-22 1.663108733570024085e-21 1.500577541255779727e-21 9.060085459566413671e-22 4.643871623634768316e-22 1.779407283507628786e-21 4.109145973614285205e-22 2.832481833125505342e-20 9.910000000000000853e+01 3.385995052893523460e-20 2.594797511669886133e-20 3.079865602355183320e-21 1.709960000007079606e-23 1.048592682998296736e-20 3.602960037010680476e-22 7.217181846241024785e-22 1.662007237134439746e-21 1.070690411117722397e-21 1.222658111956134539e-21 4.640748003659630438e-22 1.940062287602820776e-21 4.138101169947057283e-22 2.833624205497776161e-20 9.925001259445764390e+01 3.255288918745830701e-20 2.595079032554323892e-20 3.253576886950166031e-21 1.697958992450341827e-23 1.047832283390577858e-20 3.588570298767850647e-22 7.195939195480158658e-22 1.660358238697772246e-21 1.286959827769194557e-21 5.950704234394485155e-22 4.547056824971644855e-22 2.184037774545961232e-21 4.181537611196146607e-22 2.836177369786322146e-20 9.940000000000000568e+01 3.314495154827650874e-20 2.595361057783638622e-20 3.597128058771956642e-21 1.686033076929905879e-23 1.047073497385298744e-20 3.574183210893534006e-22 7.174700111615339548e-22 1.658713588957070811e-21 1.241989282519752300e-21 1.002129602500201493e-21 4.594414684861744495e-22 2.814600395433063365e-21 4.224966758945364582e-22 2.846784178177445858e-20 9.950000000000000000e+01 3.220102430052685198e-20 2.595549396765592256e-20 3.819006661056508258e-21 1.678161282058028618e-23 1.046561940454715085e-20 3.564591145080030236e-22 7.160539533406779370e-22 1.657693113363770685e-21 1.484520215645375622e-21 8.606639476089291636e-22 4.522868134233181540e-22 2.651384900218387972e-21 4.253921955278132428e-22 2.848770962046925030e-20 9.960000000000000853e+01 3.384708322041396602e-20 2.595737980797357535e-20 3.708498082732797837e-21 1.670289487186153120e-23 1.046022550310309479e-20 3.554999185459545889e-22 7.146378955198216371e-22 1.656698220541967309e-21 1.215353928554925342e-21 7.874759744331099370e-22 4.515914297015428258e-22 1.937999284309437901e-21 4.282018555005500142e-22 2.840030271056313677e-20 9.970000000000000284e+01 3.247638154028998512e-20 2.595926809825526615e-20 3.566114460209303789e-21 1.662475015981027395e-23 1.045483166621121960e-20 3.545407332893987749e-22 7.132218376989655252e-22 1.655704838193088155e-21 1.363760398990115549e-21 1.038191993135227057e-21 4.593065541883543614e-22 2.260316176299737018e-21 4.309540777672029875e-22 2.842048020898409228e-20 9.980000000000001137e+01 3.237236332155507016e-20 2.596115883796640497e-20 3.404785921483735743e-21 1.654730607035260350e-23 1.044950482045731952e-20 3.535815588254598844e-22 7.118057798781092253e-22 1.654712969037502874e-21 1.382900292728319425e-21 1.452898886834415944e-21 4.561871085769943459e-22 2.391029792285482419e-21 4.337063000338563370e-22 2.843014390184429480e-20 9.990000000000000568e+01 3.239641970185656822e-20 2.596305202657186012e-20 3.209371364357198536e-21 1.646986198089497125e-23 1.044446331817868834e-20 3.526223952422096687e-22 7.103897220572531135e-22 1.653722615797959002e-21 1.570954310830209964e-21 1.266168844302576343e-21 4.510662914601593861e-22 2.359333205948202225e-21 4.364585223005092162e-22 2.840532530983351226e-20 1.000000000000000000e+02 3.757401191307210291e-20 2.596494766353596430e-20 3.043235525383949374e-21 1.639274871801225569e-23 1.043942189900965338e-20 3.516632426286795528e-22 7.089736642363970016e-22 1.652733781199563903e-21 1.400742013325578401e-21 0.000000000000000000e+00 4.533022008085843147e-22 2.365993524537689734e-21 4.392107445671621895e-22 2.835027019438473301e-20 1.001500124812773151e+02 3.152177512885514750e-20 2.596779594569218261e-20 2.968726627661374863e-21 1.627812379641973773e-23 1.043187104798822329e-20 3.502244147620373887e-22 7.068494007630091974e-22 1.651233435087240746e-21 1.372774936801991905e-21 0.000000000000000000e+00 4.445356814169022693e-22 2.378842126338877670e-21 4.433394214796352344e-22 2.834167232862439639e-20 1.003000000000000114e+02 3.242080651766044873e-20 2.597064925921540282e-20 3.012609217561339209e-21 1.616410000006128905e-23 1.042433513823135954e-20 3.487858515113977485e-22 7.047254907738283839e-22 1.649714066317952658e-21 1.277261607988723628e-21 0.000000000000000000e+00 4.481246269321238546e-22 2.882760328589352469e-21 4.474674113671217677e-22 2.838837886840691677e-20 1.004000000000000057e+02 3.412837291203380830e-20 2.597255468424666874e-20 3.116748711796658303e-21 1.609060000006055136e-23 1.041931176602477050e-20 3.478267436867222356e-22 7.033094329529722721e-22 1.648708610319831130e-21 1.572149554763202313e-21 0.000000000000000000e+00 4.514695796235292282e-22 2.706748735427869508e-21 4.502196336337747410e-22 2.839698168937439986e-20 1.005000000000000000e+02 3.135602525255567016e-20 2.597446255495019728e-20 3.238176869414562004e-21 1.601710000005983424e-23 1.041428843451786592e-20 3.468676472917877439e-22 7.018933751321161602e-22 1.647727359224958350e-21 1.406532361373754714e-21 0.000000000000000000e+00 4.507762365558183093e-22 3.141520599671518817e-21 4.529718559004277143e-22 2.844644088819390914e-20 1.006000000000000085e+02 3.195827032348308490e-20 2.597637287078711325e-20 3.420337151973091026e-21 1.594360000005910830e-23 1.040926514376956420e-20 3.459085624216675513e-22 7.004773173112598603e-22 1.646747643189444250e-21 1.271786845299484584e-21 0.000000000000000000e+00 4.576139360639930571e-22 2.788949766943719132e-21 4.557240781670810638e-22 2.842461231618290631e-20 1.007000000000000028e+02 3.244131741287279089e-20 2.597828563121800881e-20 3.630321480260694514e-21 1.586876129038099012e-23 1.040424098136985906e-20 3.449494891724912818e-22 6.990612594904038425e-22 1.645769464954722026e-21 1.490152921544759948e-21 0.000000000000000000e+00 4.604131721861078415e-22 2.877841565823764850e-21 4.584678443365283521e-22 2.846998376168405168e-20 1.008000000000000114e+02 3.182059336696399265e-20 2.598020083570293747e-20 3.690998227563641484e-21 1.579392258070287782e-23 1.039921686353044620e-20 3.439904276414592936e-22 6.976452016695475426e-22 1.644792827264437996e-21 1.297157747017978503e-21 0.000000000000000000e+00 4.516528706340306900e-22 2.559319005349880845e-21 4.610822745127387488e-22 2.843761531949578924e-20 1.009500123823667508e+02 3.129421365163353709e-20 2.598307846160195060e-20 3.545561605283222626e-21 1.568304116214243135e-23 1.039168068528966311e-20 3.425517387801559603e-22 6.955209395967905977e-22 1.643330644708623664e-21 1.375634674410656698e-21 0.000000000000000000e+00 4.506318845475873430e-22 2.415499915159466887e-21 4.650042435053866837e-22 2.840997328720755465e-20 1.011000000000000085e+02 3.117144355598986551e-20 2.598596110807458479e-20 3.404611593447253057e-21 1.557598750005571551e-23 1.038434077235097813e-20 3.411133143456124565e-22 6.933970282069790189e-22 1.641872184929474767e-21 1.531726576758584404e-21 0.000000000000000000e+00 4.446502183578290952e-22 2.208870862453508737e-21 4.689255650413693746e-22 2.838365963893790472e-20 1.012000000000000028e+02 3.335313711033251694e-20 2.598788608336565144e-20 3.373721780125700876e-21 1.550461250005508363e-23 1.037947937445224202e-20 3.401543006811079390e-22 6.919809703861229071e-22 1.640901736897000075e-21 1.549932421177822049e-21 0.000000000000000000e+00 4.498316524973430129e-22 2.706801871456680196e-21 4.715399952175794891e-22 2.842405531755437020e-20 1.013000000000000114e+02 3.341602824124095658e-20 2.598981350000310131e-20 3.605541007577507147e-21 1.543393750005443513e-23 1.037460192298176377e-20 3.391952992373447477e-22 6.905649125652666071e-22 1.639932843159720640e-21 1.371626158509935578e-21 0.000000000000000000e+00 4.615533924728985572e-22 3.319411352627148694e-21 4.741544253937899798e-22 2.850827865846126087e-20 1.014000000000000057e+02 3.185956758450896733e-20 2.599174335744383421e-20 4.077490184499687153e-21 1.536356250005379167e-23 1.036957943303732217e-20 3.382363101182716129e-22 6.891488547444105893e-22 1.638965506474155857e-21 1.269091898581283924e-21 0.000000000000000000e+00 4.666059803802358109e-22 2.914873423765330102e-21 4.767688555700000003e-22 2.852284543141018474e-20 1.015000000000000000e+02 3.190821195197768759e-20 2.599367565514419622e-20 4.480426762237348843e-21 1.529318750005314822e-23 1.036455698251654767e-20 3.372773334290176964e-22 6.877327969235544775e-22 1.637999729598902077e-21 1.210127800718916721e-21 0.000000000000000000e+00 4.544685422073847666e-22 2.838676248637173756e-21 4.793832857462101149e-22 2.857268435070388848e-20 1.016000000000000085e+02 3.151346743649936082e-20 2.599561039256002186e-20 4.456135250109534227e-21 1.522337500005250175e-23 1.035955073163638432e-20 3.363183692759097536e-22 6.863167391026981776e-22 1.637032751448193249e-21 1.401081872213717632e-21 0.000000000000000000e+00 4.592157102591455162e-22 2.290760469413903855e-21 4.819977159224205115e-22 2.852835880155595305e-20 1.017500122850115503e+02 3.284530292702354375e-20 2.599851731024058600e-20 4.291113268956867014e-21 1.511949149268111571e-23 1.035225852713601474e-20 3.348798289813686227e-22 6.841924784085471835e-22 1.635547747866633566e-21 1.391996802569797189e-21 0.000000000000000000e+00 4.602057358850982619e-22 2.767221613692918672e-21 4.859196823697848226e-22 2.854477883479238489e-20 1.019000000000000057e+02 3.116916218878397445e-20 2.600142923765078652e-20 3.806783431231787486e-21 1.501588750005072152e-23 1.034496774629010775e-20 3.334415531150592753e-22 6.820685656401297480e-22 1.634066445815567035e-21 1.440169686780875356e-21 0.000000000000000000e+00 4.643079952449027825e-22 3.165843530180984235e-21 4.898071099503600394e-22 2.851987423696251749e-20 1.020000000000000000e+02 3.170776275640416204e-20 2.600337372847633653e-20 3.489172461048743675e-21 1.494751250005012251e-23 1.033994603508959968e-20 3.324826401943640777e-22 6.806525078192736361e-22 1.633108459096777636e-21 1.457983564324794264e-21 0.000000000000000000e+00 4.577632394024406004e-22 2.866930532919405386e-21 4.923345880852866908e-22 2.844823896532884389e-20 1.021000000000000085e+02 3.337234744895587816e-20 2.600532065628866554e-20 3.436143450088474449e-21 1.487913750004951174e-23 1.033492436151570357e-20 3.315237403600235104e-22 6.792364499984173362e-22 1.632152048806241250e-21 1.288465253515029730e-21 0.000000000000000000e+00 4.607669984796337886e-22 3.293967254413380992e-21 4.948620662202138124e-22 2.847977203776302866e-20 1.022000000000000028e+02 3.153740191268382716e-20 2.600727002054047541e-20 3.416844465276785375e-21 1.481087500004891683e-23 1.032990271407107958e-20 3.305648537259203597e-22 6.778203921775612243e-22 1.631197217716852188e-21 1.271569420527067088e-21 0.000000000000000000e+00 4.676488810927678515e-22 3.596471984320486760e-21 4.973895443551404638e-22 2.851328004272900219e-20 1.023000000000000114e+02 3.398280458156618743e-20 2.600922182068392033e-20 3.375975874910300433e-21 1.474362500004835586e-23 1.032504221471821204e-20 3.296059804072601719e-22 6.764043343567049244e-22 1.630243968603416213e-21 1.498387368283324841e-21 0.000000000000000000e+00 4.709022116715481188e-22 4.474523519711935849e-21 4.999170224900674913e-22 2.864342152423400606e-20 1.024500122010729797e+02 3.302694113828586169e-20 2.601218556277392477e-20 3.280489298151739107e-21 1.464274179482595308e-23 1.031775094553070071e-20 3.283397535227195755e-22 6.744868883541992811e-22 1.628903752098747243e-21 1.467576325541282553e-21 0.000000000000000000e+00 4.633785748450638646e-22 3.473722090788155115e-21 5.037085480719092441e-22 2.849134326776487462e-20 1.026000000000000085e+02 3.110380508765898034e-20 2.601516436147444559e-20 3.204399217227323136e-21 1.454266250004671045e-23 1.031046132818598155e-20 3.271304738408086538e-22 6.726378911693084620e-22 1.627593458024355378e-21 1.460252895212206108e-21 0.000000000000000000e+00 4.553797237146679089e-22 3.420184464568889046e-21 5.074994568948480097e-22 2.847571278497303771e-20 1.027000000000000028e+02 2.912081101037144287e-20 2.601715328514756072e-20 3.164318934911080729e-21 1.447628750004617939e-23 1.030560140319653580e-20 3.263242298809354145e-22 6.714051261056712730e-22 1.626721543488202669e-21 1.442683357538300029e-21 0.000000000000000000e+00 4.607326889826787008e-22 3.259671165179423085e-21 5.100269350297746611e-22 2.845159921719616217e-20 1.028000000000000114e+02 3.196762392970394259e-20 2.601914452537660890e-20 3.199966873370523022e-21 1.440991250004563658e-23 1.030074151560410408e-20 3.255179924379166689e-22 6.701723610420338960e-22 1.625850980274627761e-21 1.420889179077402955e-21 0.000000000000000000e+00 4.590847438196671802e-22 3.592627435212985189e-21 5.125544131647016887e-22 2.849454344927927022e-20 1.029000000000000057e+02 3.307128709829509558e-20 2.602113808162976261e-20 3.309225488482485570e-21 1.434423750004511829e-23 1.029588174521177384e-20 3.247117615602955848e-22 6.689395959783967070e-22 1.624959497405046752e-21 1.413972478877085197e-21 0.000000000000000000e+00 4.553026211397512138e-22 4.105038968004693397e-21 5.150818912996284341e-22 2.857573570839760373e-20 1.030000000000000000e+02 3.246199107235929374e-20 2.602313395337475502e-20 3.442294591461608011e-21 1.427886250004460798e-23 1.029102204611750255e-20 3.239055372970974704e-22 6.677068309147596120e-22 1.624063775282692428e-21 1.524178808206843297e-21 0.000000000000000000e+00 4.546158558600877374e-22 3.576459121790832781e-21 5.176093694345550855e-22 2.852604665440978859e-20 1.031500121182736507e+02 3.328866631068509614e-20 2.602613234380020684e-20 3.922679867916613739e-21 1.418079243530331161e-23 1.028369971539267111e-20 3.226961157139502875e-22 6.658575339294598234e-22 1.622728154078610430e-21 1.339626772639035437e-21 0.000000000000000000e+00 4.622598254110969320e-22 3.847410924515638189e-21 5.214409372828417457e-22 2.861407283600758051e-20 1.033000000000000114e+02 3.234487240561195391e-20 2.602913545623124077e-20 4.155855967216196561e-21 1.408716363640666636e-23 1.027617020567740969e-20 3.214869046916683304e-22 6.640085357238477629e-22 1.621432017881759271e-21 1.433341300170344676e-21 0.000000000000000000e+00 4.624330372310485147e-22 4.052088072801816631e-21 5.252873003557078145e-22 2.867967682892680757e-20 1.034000000000000057e+02 3.141570546921672540e-20 2.603114058461179533e-20 3.929909814216083681e-21 1.402473939398189988e-23 1.027115016923457981e-20 3.206807073862895678e-22 6.627757706602105739e-22 1.620569562228553182e-21 1.459591139173930991e-21 0.000000000000000000e+00 4.663163221629321890e-22 3.462617336243493496e-21 5.278517495822681708e-22 2.857176492296066048e-20 1.035000000000000000e+02 2.944336619892230491e-20 2.603314802581601127e-20 3.708971567930953293e-21 1.396210000004202709e-23 1.026656742044239918e-20 3.198745169479195812e-22 6.615430055965733849e-22 1.619708473151122852e-21 1.382683538069569844e-21 0.000000000000000000e+00 4.682743293120675630e-22 3.633453066123289869e-21 5.304161988088284330e-22 2.855979165363358316e-20 1.036000000000000085e+02 3.126521332279676354e-20 2.603515777930891638e-20 3.531036675402056414e-21 1.389860000004155864e-23 1.026217192781218572e-20 3.190683334286107182e-22 6.603102405329360078e-22 1.618848752830172801e-21 1.511089132448056742e-21 0.000000000000000000e+00 4.601567332280106138e-22 4.906291947571926946e-21 5.329806480353890714e-22 2.873359385065882704e-20 1.037000000000000028e+02 3.207968220663713319e-20 2.603716984455505702e-20 3.363289884185788146e-21 1.383510000004110194e-23 1.025777647231439812e-20 3.182621568809429821e-22 6.590774754692989129e-22 1.617990403447571950e-21 1.478306894107261639e-21 0.000000000000000000e+00 4.617494864222505890e-22 4.558033429424299939e-21 5.355450972619494276e-22 2.865454152392568254e-20 1.038500120365905417e+02 3.225415495468672085e-20 2.604019251852959925e-20 3.500696206749133343e-21 1.374122905418360300e-23 1.025071959078525839e-20 3.170528082131280408e-22 6.572281794909600289e-22 1.616705351673554925e-21 1.618436509091468161e-21 0.000000000000000000e+00 4.660683330963501807e-22 3.990289190090097882e-21 5.393920797740430865e-22 2.859405632125159636e-20 1.040000000000000000e+02 2.993659354010314878e-20 2.604321990545174405e-20 3.789852510700394637e-21 1.365014545458515479e-23 1.024343284450977800e-20 3.158436696016267156e-22 6.553791802783871578e-22 1.615423602765705648e-21 1.568725298213431296e-21 0.000000000000000000e+00 4.646394642622076917e-22 4.795968869191741563e-21 5.432384449416306845e-22 2.875156473425921824e-20 1.041000000000000085e+02 2.948139996005870853e-20 2.604524121234742785e-20 3.621439025022969086e-21 1.358941818185741397e-23 1.023857466529126497e-20 3.150375214770938704e-22 6.541464152147498748e-22 1.614570758977949290e-21 1.793512545237213827e-21 0.000000000000000000e+00 4.701830677012558684e-22 5.722729410100875772e-21 5.458028941681913229e-22 2.891223431777914696e-20 1.042000000000000028e+02 3.139924560172864681e-20 2.604726482831239526e-20 3.433772349320706700e-21 1.352936969700847813e-23 1.023371669524511431e-20 3.142313805952420443e-22 6.529136501511126858e-22 1.613719297054818545e-21 1.671964834219832627e-21 0.000000000000000000e+00 4.720004076929902556e-22 5.518225411325477150e-21 5.483673433947516791e-22 2.884230980375192386e-20 1.043000000000000114e+02 3.023262317869045949e-20 2.604929075280852342e-20 3.325485837336374247e-21 1.346961212125044443e-23 1.022885883306717170e-20 3.134252470119561664e-22 6.516808850874753087e-22 1.612869219184844658e-21 1.726063321520534181e-21 0.000000000000000000e+00 4.737361260660772647e-22 6.660706057145008514e-21 5.508664207361521546e-22 2.907319365353272508e-20 1.044000000000000057e+02 3.331797777200435084e-20 2.605131898529722000e-20 3.279287197378716002e-21 1.340985454549242249e-23 1.022400100325840439e-20 3.126191207836978636e-22 6.504481200238382138e-22 1.612012108557183494e-21 1.388576540631864274e-21 0.000000000000000000e+00 4.760093938714522756e-22 5.851333073887705617e-21 5.533286187125722057e-22 2.887514016068475909e-20 1.045500119560012422e+02 3.229414708316777165e-20 2.605436590338431643e-20 3.225550117815059646e-21 1.332097477504739978e-23 1.021671393117309952e-20 3.114098489782502223e-22 6.485988250389760916e-22 1.610699435982581338e-21 1.634773978582309505e-21 0.000000000000000000e+00 4.639164870826372684e-22 6.426438242197654449e-21 5.570222100576229970e-22 2.900387341518438557e-20 1.047000000000000028e+02 3.134347643748088215e-20 2.605741752532627285e-20 3.221650597581380543e-21 1.323261818185475689e-23 1.020945844956518841e-20 3.102007868024949257e-22 6.467498248329264587e-22 1.609395659210292815e-21 1.631819250714633548e-21 0.000000000000000000e+00 4.578184487109847981e-22 5.951001646134000773e-21 5.607152126418327350e-22 2.890168119315136428e-20 1.048000000000000114e+02 3.234593655558139593e-20 2.605945498439055081e-20 3.329893092091521182e-21 1.317379393943010832e-23 1.020475209946871161e-20 3.093946905707392462e-22 6.455170597692891757e-22 1.608552488799666470e-21 1.581052190448756152e-21 0.000000000000000000e+00 4.598749690400050311e-22 5.365820324986006976e-21 5.631774106182530681e-22 2.879654123464934825e-20 1.049000000000000057e+02 3.293413784353757344e-20 2.606149474874783923e-20 3.541600201797537213e-21 1.311573333336910029e-23 1.020004571790457077e-20 3.085886019852200717e-22 6.442842947056519867e-22 1.607710715622881040e-21 1.543240732332663595e-21 0.000000000000000000e+00 4.682418948064792898e-22 4.215331233921201460e-21 5.656396085946731192e-22 2.862814028415854895e-20 1.050000000000000000e+02 3.148861039139333045e-20 2.606353681785687056e-20 3.724899861706003246e-21 1.305767272730809372e-23 1.019533936893750895e-20 3.077825211060144737e-22 6.430515296420147977e-22 1.606870341875796268e-21 1.616024372669867534e-21 0.000000000000000000e+00 4.717434506155835047e-22 7.188680392344621552e-21 5.681018065710931702e-22 2.924127503263130347e-20 1.051500118877787031e+02 3.102503390560659869e-20 2.606660448504935106e-20 3.709371948253948021e-21 1.297082956242075780e-23 1.018853646341868387e-20 3.065733185462581598e-22 6.412022354981762836e-22 1.605612310423347773e-21 1.598749288702249915e-21 0.000000000000000000e+00 4.692060547547083674e-22 6.085747852505780178e-21 5.717953962363701514e-22 2.898717478552429254e-20 1.053000000000000114e+02 3.032494930776053204e-20 2.606967684827542384e-20 3.763730121837424501e-21 1.288501818185231983e-23 1.018173530062266131e-20 3.053643253165540980e-22 6.393532344511029486e-22 1.604357639185367686e-21 1.548202490522869849e-21 0.000000000000000000e+00 4.667267112631222614e-22 5.906562598956048365e-21 5.754884005003540757e-22 2.895463748576951499e-20 1.054000000000000057e+02 3.131431078126431758e-20 2.607172813097019278e-20 3.890717530263153278e-21 1.282780606063982315e-23 1.017704670277403727e-20 3.045582758761056263e-22 6.381204693874657596e-22 1.603574122250015294e-21 1.557173846248444971e-21 0.000000000000000000e+00 4.651742055055857874e-22 5.347608489495617503e-21 5.779505984767741267e-22 2.886327526634998167e-20 1.055000000000000000e+02 3.257241522875821335e-20 2.607378171570387281e-20 3.957920617199749306e-21 1.277101818185157188e-23 1.017234097093720638e-20 3.037522344519795772e-22 6.368877043238286646e-22 1.602814880299276392e-21 1.669332781600216525e-21 0.000000000000000000e+00 4.706896664685499154e-22 4.762439099079274175e-21 5.803595163168107241e-22 2.877632157599313309e-20 1.056000000000000085e+02 3.198951264119922163e-20 2.607583760193258130e-20 3.731753953188820770e-21 1.271465454548755424e-23 1.016763523524299209e-20 3.029462011081622462e-22 6.356549392601912876e-22 1.602056810222651217e-21 1.435307529560385416e-21 0.000000000000000000e+00 4.686231680506232394e-22 4.768569052213471068e-21 5.827260941974755347e-22 2.873459966067532352e-20 1.057500118203303145e+02 3.080048671912827196e-20 2.607892598894444519e-20 3.314932761759107893e-21 1.263010242857354053e-23 1.016039473969013487e-20 3.017370711107964653e-22 6.338056459478329661e-22 1.600887906374961973e-21 1.435944994111145870e-21 0.000000000000000000e+00 4.637733028586490523e-22 4.373821643940461822e-21 5.862762407557948497e-22 2.862061489537507452e-20 1.059000000000000057e+02 3.143157197883856805e-20 2.608201906414343405e-20 3.173378796844353336e-21 1.254643636366823567e-23 1.015311036796758145e-20 3.005281502087161670e-22 6.319566440692796265e-22 1.599713303516723356e-21 1.433922852081829606e-21 0.000000000000000000e+00 4.694727216762358619e-22 3.526272482707557447e-21 5.898258278394692142e-22 2.848746495464112203e-20 1.060000000000000000e+02 3.629570686931645881e-20 2.608408415090463718e-20 3.121712380529324017e-21 1.249080000003151307e-23 1.014834450554693540e-20 2.997221498397801309e-22 6.307238790056424375e-22 1.598948586102723013e-21 1.493830332363742919e-21 0.000000000000000000e+00 4.715423459513708579e-22 3.363593113502942642e-21 5.921924057201336487e-22 2.846535087937155150e-20 1.061000000000000085e+02 3.422419554750075639e-20 2.608615153643487143e-20 3.146123010935627045e-21 1.243516363639479487e-23 1.014363913277305346e-20 2.989161578815018962e-22 6.294911139420050605e-22 1.598196359099051747e-21 1.505381690991208409e-21 0.000000000000000000e+00 4.741333523269462369e-22 3.762279361013036151e-21 5.945589836007984593e-22 2.851873114028495559e-20 1.062000000000000028e+02 3.259110972116208000e-20 2.608822122018763912e-20 3.187735785878136040e-21 1.238040000003081102e-23 1.013893400840095891e-20 2.981101744021008072e-22 6.282583488783679655e-22 1.597445313989855681e-21 1.391734485408886541e-21 0.000000000000000000e+00 4.705781252692724735e-22 3.256145422378423706e-21 5.969255614814628937e-22 2.845536264964339258e-20 1.063500117536429883e+02 3.287865746206920347e-20 2.609133029759081827e-20 3.074806099928404973e-21 1.229839357470546334e-23 1.013215703412199885e-20 2.969011205015401424e-22 6.264090563881076051e-22 1.596320878029911381e-21 1.452798810396895571e-21 0.000000000000000000e+00 4.644873782528254184e-22 3.481507190911174530e-21 6.004757064615747780e-22 2.847295772999545013e-20 1.065000000000000000e+02 3.041222609988738388e-20 2.609444405530960899e-20 2.872099100073838595e-21 1.221778823532390561e-23 1.012556888755967426e-20 2.956922755304946778e-22 6.245600536874562105e-22 1.595199286709623325e-21 1.681570453182012172e-21 0.000000000000000000e+00 4.681510667477704205e-22 3.437207935660664394e-21 6.040252951234564791e-22 2.845952420323665220e-20 1.066000000000000085e+02 3.185478120991814094e-20 2.609652292647879488e-20 2.788607839437080125e-21 1.216543529414709140e-23 1.012111430969744414e-20 2.948863266637230782e-22 6.233272886238189274e-22 1.594452985861306504e-21 1.481025924971152141e-21 0.000000000000000000e+00 4.803662322461621187e-22 3.896625357383982803e-21 6.063918730041212897e-22 2.849974228598694230e-20 1.067000000000000028e+02 3.095501374618720874e-20 2.609860409313150479e-20 2.732249926650904357e-21 1.211308235297029335e-23 1.011640986036149902e-20 2.940803866282119262e-22 6.220945235601817384e-22 1.593707875251388602e-21 1.388748884213944017e-21 0.000000000000000000e+00 4.803965327036248106e-22 2.724936725563081006e-21 6.087268701337873134e-22 2.835335682023829191e-20 1.068000000000000114e+02 3.259339951893490730e-20 2.610068755471861999e-20 2.910511153259450496e-21 1.206055757578635925e-23 1.011170541421097885e-20 2.932744554967678624e-22 6.208617584965443614e-22 1.592963956550075373e-21 1.548579774012563514e-21 0.000000000000000000e+00 4.601096144665099649e-22 2.689123196287171577e-21 6.109991888548615118e-22 2.837582095705423036e-20 1.069500116877038920e+02 3.031980443415388060e-20 2.610381729294421569e-20 3.528826867063962777e-21 1.198073317469253902e-23 1.010480432376742313e-20 2.920654814632313926e-22 6.190124668191583749e-22 1.591836463648478937e-21 1.475040593972677896e-21 0.000000000000000000e+00 4.599396686400950565e-22 3.352004148577750379e-21 6.144079325183559547e-22 2.851266824517731446e-20 1.071000000000000085e+02 3.229125070954005356e-20 2.610695170358904698e-20 3.991592553017475867e-21 1.190092121214904479e-23 1.009821670246174692e-20 2.908567162669999733e-22 6.171634633056327003e-22 1.590684276574310461e-21 1.663424187267125270e-21 0.000000000000000000e+00 4.726926384532755008e-22 3.287211964758167880e-21 6.178161450180836368e-22 2.857715001622352481e-20 1.072000000000000028e+02 3.036188022302809104e-20 2.610904943576221073e-20 4.246617504201526025e-21 1.184975294120398891e-23 1.009382511649962988e-20 2.900799517252341397e-22 6.159678957653279763e-22 1.589917557990157642e-21 1.731289796075866698e-21 0.000000000000000000e+00 4.767132383884552946e-22 3.352464445638671598e-21 6.200884637391575530e-22 2.862588368356838401e-20 1.073000000000000114e+02 3.153241213800745236e-20 2.611116617125377593e-20 4.220243764457030324e-21 1.179881176473308618e-23 1.008918370770133198e-20 2.893990241878894992e-22 6.148946982731479344e-22 1.589174071243070153e-21 1.431142739546540206e-21 0.000000000000000000e+00 4.754466523143869129e-22 3.624455222448773783e-21 6.223607824602318455e-22 2.863879837791876222e-20 1.074000000000000057e+02 3.138943642207833361e-20 2.611328510998458472e-20 3.904290853560305985e-21 1.174787058826219520e-23 1.008447985022722584e-20 2.887181010229371089e-22 6.138215007809681746e-22 1.588437298170545115e-21 1.463066989527106670e-21 0.000000000000000000e+00 4.673113332430690658e-22 2.990477659484675251e-21 6.246331011813057617e-22 2.852226067888953306e-20 1.075500116225005343e+02 3.173444573295686104e-20 2.611646789476677386e-20 3.595561182505646035e-21 1.167227652804382490e-23 1.007743791413885097e-20 2.876966454023852104e-22 6.122115798103141918e-22 1.587334310559965376e-21 1.622440346636364719e-21 0.000000000000000000e+00 4.579526614409310285e-22 2.689784750877023361e-21 6.280418433631722361e-22 2.846052461119046058e-20 1.077000000000000028e+02 2.967503661892184623e-20 2.611965514024761424e-20 3.594824089663244349e-21 1.159710588237895974e-23 1.007059595086054548e-20 2.866753580739965239e-22 6.106019083044286132e-22 1.586234207493405480e-21 1.625089207803514314e-21 0.000000000000000000e+00 4.598300761719337881e-22 3.028052423236595381e-21 6.314500573445278867e-22 2.849504391779166803e-20 1.078000000000000114e+02 3.453542677651912932e-20 2.612178288656862511e-20 3.673224596399534686e-21 1.154707058826102395e-23 1.006603434825336481e-20 2.859944527116588938e-22 6.095287108122485713e-22 1.585502259027958451e-21 1.584268344045672827e-21 0.000000000000000000e+00 4.624092687309220795e-22 2.799665754182382693e-21 6.337223760656020851e-22 2.847974538748846302e-20 1.079000000000000057e+02 3.085794113140213858e-20 2.612391283344357049e-20 3.819930968802337442e-21 1.149777647061368118e-23 1.006152412328347930e-20 2.853135518797315049e-22 6.084555133200688116e-22 1.584771520900221996e-21 1.631524465947562141e-21 0.000000000000000000e+00 4.626864236299540598e-22 2.643124066495512281e-21 6.359946947866760013e-22 2.848709816422806268e-20 1.080500115687175651e+02 3.070894691397164873e-20 2.612711212553372605e-20 4.068152013470740895e-21 1.142382959144541868e-23 1.005493723637396018e-20 2.842921304271323252e-22 6.068455929266122714e-22 1.583677602499631233e-21 1.606120414916646104e-21 0.000000000000000000e+00 4.588144700561956564e-22 3.050467345681144987e-21 6.392686722274772336e-22 2.856114510066883136e-20 1.082000000000000028e+02 3.221464700711187491e-20 2.613031587200810671e-20 4.350329395380000558e-21 1.135030588237753037e-23 1.004832014175914797e-20 2.832708768931030469e-22 6.052359208435292501e-22 1.582586585295105577e-21 1.692562008343124735e-21 0.000000000000000000e+00 4.572356056448143537e-22 3.141135103786680853e-21 6.425395079927632477e-22 2.861803959813130965e-20 1.083000000000000114e+02 3.232893219009190366e-20 2.613245461571296019e-20 4.377579966042990992e-21 1.130160000002430882e-23 1.004361684855560668e-20 2.825899945110820720e-22 6.041627233513492082e-22 1.581860705271524863e-21 1.751460997478405849e-21 0.000000000000000000e+00 4.617595690831044826e-22 3.187508697844375320e-21 6.447202333575930142e-22 2.863121765003683270e-20 1.084000000000000057e+02 3.255263906618493759e-20 2.613459555727693285e-20 4.241945113921791835e-21 1.125289411767109460e-23 1.003891358137971310e-20 2.819091168251907920e-22 6.030895258591694485e-22 1.581136043963752412e-21 1.554547705767151767e-21 0.000000000000000000e+00 4.560025267837119648e-22 2.614581933134582107e-21 6.469009587224224045e-22 2.854143221948192027e-20 1.085000000000000000e+02 3.070085966001539709e-20 2.613673869615991870e-20 4.083646619783708324e-21 1.120440000002376285e-23 1.003421044628106177e-20 2.812282438695382446e-22 6.020163283669895947e-22 1.580461688800829864e-21 1.450159569643496890e-21 0.000000000000000000e+00 4.504593262386714927e-22 2.789973351651361835e-21 6.490816840872518889e-22 2.852965634313798807e-20 1.086500115048314257e+02 3.306679056053369326e-20 2.613995777034510338e-20 3.715454954499165082e-21 1.113239447770429495e-23 1.002777854699234758e-20 2.802068650485005745e-22 6.004064086591574380e-22 1.579426952945506512e-21 1.481222213115320501e-21 0.000000000000000000e+00 4.607898172628898840e-22 3.496887794904504899e-21 6.523530230232732816e-22 2.855962522043406168e-20 1.088000000000000114e+02 2.998006768528326775e-20 2.614318129131632534e-20 3.498562681702617630e-21 1.106040000002299478e-23 1.002139217707634288e-20 2.791856537300923111e-22 5.987967358904499392e-22 1.578391971173953937e-21 1.385197217961780489e-21 0.000000000000000000e+00 4.635303766022128317e-22 3.445594377654636503e-21 6.556238601817407182e-22 2.852188126240140667e-20 1.089000000000000057e+02 3.324316516315160515e-20 2.614533321406684709e-20 3.587817043257625983e-21 1.101303529414039544e-23 1.001695258050526759e-20 2.785048000431651206e-22 5.977235383982700854e-22 1.577719357933876899e-21 1.790283180364448173e-21 0.000000000000000000e+00 4.596988690141376468e-22 2.952019752838338572e-21 6.578045855465702026e-22 2.850049019634396796e-20 1.090000000000000000e+02 3.302984603728904579e-20 2.614748733143023079e-20 3.668702358951750249e-21 1.096574117649309124e-23 1.001239184490517348e-20 2.778239512620672128e-22 5.966503409060902316e-22 1.577058552038654934e-21 1.614756696160271465e-21 0.000000000000000000e+00 4.574901862955188068e-22 3.145741982118135938e-21 6.599853109113995930e-22 2.852134082735369628e-20 1.091500114521295046e+02 3.197437644240626184e-20 2.615072286838274011e-20 3.629916929105113066e-21 1.089479466467709509e-23 1.000555026655220181e-20 2.768026093974903367e-22 5.950404217638538586e-22 1.576069221832543860e-21 1.391029113685938370e-21 0.000000000000000000e+00 4.667708117702322248e-22 3.084191128685947085e-21 6.632566486981368675e-22 2.849855130617122063e-20 1.093000000000000114e+02 3.161128484186032868e-20 2.615396284577220586e-20 3.674122304959834286e-21 1.082491764708057918e-23 9.998890832506026082e-21 2.757814347170927960e-22 5.934307484295505762e-22 1.575082391317182068e-21 1.485851441746559527e-21 0.000000000000000000e+00 4.620743430327876247e-22 3.009934113165146238e-21 6.664030073381284012e-22 2.850159725069140145e-20 1.094000000000000057e+02 3.452035993828844204e-20 2.615612573615980285e-20 3.830933454594357624e-21 1.077832941178621749e-23 9.994469447166118623e-21 2.751006059244529606e-22 5.923575509373707223e-22 1.574425761094482500e-21 1.558448204802935645e-21 0.000000000000000000e+00 4.695175537625529542e-22 3.189124180842574196e-21 6.684987093631907384e-22 2.854611174497122127e-20 1.095000000000000000e+02 3.192711470625993616e-20 2.615829081844476976e-20 3.980870189555176951e-21 1.073194285716412509e-23 9.990052419217790613e-21 2.744197822220255616e-22 5.912843534451909626e-22 1.573770178062479084e-21 1.699483424480548564e-21 0.000000000000000000e+00 4.817378669194727212e-22 4.352808409580554755e-21 6.705944113882531696e-22 2.872844231238806976e-20 1.096500113999082089e+02 3.279063209533634927e-20 2.616154279780618809e-20 4.098480335256337067e-21 1.066508063320468986e-23 9.983484904788862976e-21 2.733984786836137878e-22 5.896744348633921160e-22 1.572788695364322498e-21 1.655458200641225647e-21 0.000000000000000000e+00 4.860936151211668400e-22 3.730023666588533006e-21 6.737382033339541498e-22 2.865543408731121627e-20 1.098000000000000114e+02 3.266096188341809081e-20 2.616479921123989703e-20 4.118073645276171474e-21 1.059822857144914075e-23 9.976918440152339971e-21 2.723773420377154811e-22 5.880647609686512131e-22 1.571809725203300881e-21 1.624217670994155912e-21 0.000000000000000000e+00 4.875320889298668246e-22 3.231035925600713154e-21 6.768815174634409335e-22 2.859647513085875743e-20 1.099000000000000057e+02 3.236407030513519053e-20 2.616697305566850291e-20 4.007741259788482916e-21 1.055329411766740810e-23 9.972515960838072726e-21 2.716965390797469146e-22 5.869915634764713593e-22 1.571136711695126920e-21 1.444796630321798889e-21 0.000000000000000000e+00 4.814602534354881910e-22 4.065813859299750278e-21 6.789772194885032707e-22 2.867789387692446388e-20 1.100000000000000000e+02 3.164686511547442487e-20 2.616914908926970613e-20 3.889795848546134853e-21 1.050811764707895495e-23 9.968107248549629289e-21 2.710157414057233031e-22 5.859183659842915995e-22 1.570459323793353110e-21 1.487441747556460103e-21 0.000000000000000000e+00 4.656886834924466329e-22 4.094928945328630603e-21 6.810729215135657019e-22 2.866815119578360752e-20 1.101500113481610157e+02 3.102573176876850436e-20 2.617241749061201956e-20 3.608126647824083876e-21 1.044034781449764613e-23 9.961493729762769143e-21 2.699944776327175903e-22 5.843084479578423636e-22 1.569445105284626416e-21 1.564360777438316664e-21 0.000000000000000000e+00 4.829948477127006549e-22 3.823044918611220914e-21 6.842167123747996046e-22 2.859872875638921211e-20 1.103000000000000114e+02 2.918941280715674256e-20 2.617569031964646606e-20 3.334451140052356009e-21 1.037482285716232965e-23 9.954927581391175355e-21 2.689733804885470564e-22 5.826987735077518500e-22 1.568473989283647964e-21 1.559063588568012926e-21 0.000000000000000000e+00 4.693098555857658716e-22 4.519676419117933367e-21 6.873600275887533718e-22 2.866720920935706629e-20 1.104000000000000057e+02 3.137044835786856652e-20 2.617787510447378014e-20 3.173378639920860405e-21 1.033150857144782922e-23 9.950549993149504323e-21 2.682926043535623859e-22 5.816255760155719962e-22 1.567827853057737121e-21 1.497697544071026863e-21 0.000000000000000000e+00 4.634705179008157166e-22 4.874538171162123783e-21 6.894557296138158030e-22 2.870414180449774192e-20 1.105000000000000000e+02 3.125126505238464979e-20 2.618006207573973171e-20 3.014551100886006762e-21 1.028819428573333466e-23 9.946203967078907807e-21 2.676118337062046673e-22 5.805523785233922364e-22 1.567182777147670112e-21 1.728613559602928976e-21 0.000000000000000000e+00 4.631668835071171980e-22 3.799353850476864096e-21 6.914829220127448517e-22 2.853753376798428081e-20 1.106500112968814875e+02 3.082255290003920282e-20 2.618334687856583959e-20 2.783965392729182155e-21 1.022390374283740374e-23 9.939873804878975090e-21 2.665906112118315885e-22 5.789424610472736265e-22 1.566217081606652704e-21 1.594244873164178387e-21 0.000000000000000000e+00 4.632139248213205612e-22 4.147116849401192576e-21 6.945001371496836919e-22 2.855548434520235867e-20 1.108000000000000114e+02 2.953480186515264089e-20 2.618663610268859381e-20 2.641275667619471710e-21 1.015979428573272928e-23 9.933544664859675272e-21 2.655695551119070742e-22 5.773327860468524869e-22 1.565253924411149909e-21 1.567996833093353858e-21 0.000000000000000000e+00 4.491987263639342132e-22 3.842709222021000646e-21 6.975168978525563557e-22 2.849840097429430436e-20 1.109000000000000057e+02 3.167946283227139433e-20 2.618883181422649033e-20 2.652712343079344696e-21 1.011694117648883321e-23 9.929198704877929035e-21 2.648888068392384848e-22 5.762595885546726331e-22 1.564613102863027340e-21 1.508876214749924153e-21 0.000000000000000000e+00 4.560327319171329747e-22 4.658719495391548777e-21 6.995282231324933042e-22 2.861833013215784582e-20 1.110000000000000000e+02 3.383564783233123445e-20 2.619102970945991929e-20 2.703596049895158164e-21 1.007364705884157969e-23 9.924820893623051134e-21 2.642080642684743742e-22 5.751863910624928734e-22 1.563973348179953127e-21 1.477878300064887750e-21 0.000000000000000000e+00 4.509415305022553410e-22 5.656590076221430818e-21 7.015395484124303468e-22 2.880112740108129452e-20 1.111500112460633147e+02 3.163652812895089447e-20 2.619433089320428126e-20 3.097170275964734620e-21 1.000870101348681191e-23 9.918253732453305134e-21 2.631868846447406295e-22 5.735764741317536132e-22 1.563015644628972745e-21 1.670449850589564883e-21 0.000000000000000000e+00 4.501590145855601838e-22 4.668202299863784404e-21 7.045567625272504238e-22 2.867455537467878739e-20 1.113000000000000114e+02 3.205568256659532809e-20 2.619763649183452481e-20 3.541310922073921447e-21 9.945302857160315113e-24 9.911733634776866810e-21 2.621658712117754741e-22 5.719667985859531239e-22 1.562019704527020731e-21 1.796282870145964736e-21 0.000000000000000000e+00 4.638492055867478520e-22 4.595496090315222540e-21 7.075735242522418508e-22 2.872275089061609548e-20 1.114000000000000057e+02 2.983618880568330328e-20 2.619984311634939894e-20 3.787228337357783654e-21 9.903931428588694802e-24 9.907386950313321323e-21 2.614851518951068596e-22 5.708936010937732701e-22 1.561357006944750176e-21 1.553815985526232593e-21 0.000000000000000000e+00 4.471798447059411857e-22 4.455823296671712491e-21 7.095848495321787993e-22 2.871821038302188695e-20 1.115000000000000000e+02 3.180323797286188643e-20 2.620205192180766667e-20 3.986141921066833184e-21 9.862560000017075959e-24 9.903065768804347585e-21 2.608044385059132719e-22 5.698204036015935103e-22 1.560700804336180804e-21 1.710324280331250339e-21 0.000000000000000000e+00 4.472203798009807379e-22 4.334671160819929016e-21 7.115961748121157479e-22 2.873598999282880536e-20 1.116500111957003014e+02 3.075147356549883098e-20 2.620536946583682324e-20 4.014530116154151259e-21 9.800863990804570154e-24 9.896736407478977678e-21 2.597833034287778160e-22 5.682104872113488096e-22 1.559786381412776678e-21 1.590419564459362699e-21 0.000000000000000000e+00 4.483064901101616469e-22 4.926978272947024824e-21 7.146133879139718118e-22 2.882920069729825301e-20 1.118000000000000114e+02 3.166100834081576201e-20 2.620869141832595701e-20 4.044518061990641850e-21 9.739497142873678815e-24 9.890407998748747217e-21 2.587623343709740321e-22 5.666008111250537608e-22 1.558924844569722702e-21 1.667600581889945136e-21 0.000000000000000000e+00 4.491484253584571446e-22 5.166769866565569378e-21 7.175469650922312222e-22 2.888053235416683482e-20 1.119000000000000057e+02 3.190160481151687150e-20 2.621090894203913417e-20 4.097194798061080386e-21 9.698582857159217312e-24 9.886086844820704754e-21 2.580816451619376311e-22 5.655276136328739070e-22 1.558351558438581581e-21 1.810342489769277651e-21 0.000000000000000000e+00 4.442685017586525675e-22 4.381594852591410890e-21 7.194761870599243741e-22 2.876698074202316225e-20 1.120000000000000000e+02 3.627968972586354809e-20 2.621312864393459246e-20 4.178448958373269958e-21 9.659111111127292605e-24 9.881740739313805110e-21 2.574009621179931770e-22 5.644544161406941472e-22 1.557779165205264434e-21 1.553839889634167806e-21 0.000000000000000000e+00 4.353719953900899335e-22 4.337095373025600472e-21 7.214054090276176200e-22 2.875730814115372914e-20 1.121500111457863369e+02 3.270885021045011641e-20 2.621646252754774280e-20 4.596523946379380457e-21 9.600440085219476108e-24 9.875221338285044187e-21 2.563798733529527927e-22 5.628445002861248553e-22 1.556922188094196219e-21 1.585415418923263065e-21 0.000000000000000000e+00 4.505000592139932155e-22 4.740962830310920454e-21 7.242994570061159707e-22 2.888728769516078494e-20 1.123000000000000114e+02 3.252280156312298615e-20 2.621981026824598194e-20 4.795569524789368704e-21 9.541668571444222023e-24 9.868893973339884759e-21 2.554176536179368946e-22 5.613111470887983149e-22 1.556067352738041216e-21 1.604562558456942053e-21 0.000000000000000000e+00 4.537146367484937600e-22 4.649846423229035088e-21 7.271930749306976399e-22 2.890680041723222472e-20 1.124000000000000057e+02 3.201815831663819217e-20 2.622205583425513405e-20 4.607730783077836824e-21 9.502011428586915653e-24 9.864675171396383265e-21 2.548438364615641729e-22 5.603768629407523541e-22 1.555498540941316471e-21 1.809996139371457716e-21 0.000000000000000000e+00 4.424758060471134348e-22 4.771173214134598792e-21 7.291222968983907918e-22 2.890857016554885636e-20 1.125000000000000000e+02 3.070215207440305642e-20 2.622430350871746417e-20 4.419745923516935310e-21 9.462354285729607814e-24 9.860459330577089566e-21 2.542700223101910263e-22 5.594425787927064874e-22 1.554927975437667562e-21 1.782871545986761906e-21 0.000000000000000000e+00 4.355812739541866323e-22 4.441891515743156496e-21 7.310515188660839437e-22 2.882543364982521271e-20 1.126500110963154810e+02 3.014132544730124137e-20 2.622767922245157218e-20 4.181409955179692070e-21 9.402978520083773338e-24 9.854174836895542330e-21 2.534092430906044454e-22 5.580410488995209757e-22 1.554037928286323418e-21 1.899533375802872781e-21 0.000000000000000000e+00 4.424238265023176224e-22 4.847794588367610388e-21 7.339455658901797171e-22 2.886372482950251152e-20 1.128000000000000114e+02 3.111686170142196060e-20 2.623105917740100056e-20 4.058625401679790456e-21 9.344354285729122155e-24 9.847891320258282544e-21 2.525485980908968587e-22 5.566397263485684172e-22 1.553149995064436569e-21 1.621572119212906590e-21 0.000000000000000000e+00 4.362323048961525894e-22 4.063515868783518884e-21 7.368391847691640576e-22 2.870858317542465044e-20 1.129000000000000057e+02 3.014841807241436870e-20 2.623331528025188970e-20 4.116941323591399689e-21 9.305268571443247399e-24 9.843613461921941801e-21 2.519747961652826594e-22 5.557054422005224565e-22 1.552577686225074864e-21 1.544328399721828666e-21 0.000000000000000000e+00 4.273115640550037811e-22 5.529078500236264225e-21 7.387684067368572095e-22 2.895685893770996434e-20 1.130500110570538652e+02 3.062822998574293504e-20 2.623670363254397668e-20 4.168153305225055322e-21 9.247784748650933099e-24 9.837139791792368046e-21 2.511140356676598923e-22 5.543039126741521198e-22 1.551732798531789158e-21 1.715040113262320955e-21 0.000000000000000000e+00 4.373786278844064652e-22 5.193734840523859930e-21 7.416196505337108023e-22 2.891268327224411789e-20 1.132000000000000028e+02 2.919189818433995874e-20 2.624009622106630697e-20 4.124730893047095544e-21 9.191622222236416312e-24 9.830718285774671166e-21 2.502534091268961082e-22 5.529025897563845743e-22 1.550890069786144752e-21 1.477679091998676251e-21 0.000000000000000000e+00 4.476233637233595443e-22 5.114382796284657519e-21 7.443998789902878695e-22 2.888023015704018853e-20 1.133000000000000114e+02 3.245505490714099521e-20 2.624236074361162587e-20 3.947061733776174789e-21 9.154177777791817996e-24 9.826529768166230060e-21 2.496796197653582396e-22 5.519683056083385195e-22 1.550329341098388010e-21 1.622315276568253431e-21 0.000000000000000000e+00 4.404611474895356864e-22 4.171777612573060902e-21 7.462535012653484112e-22 2.871164625054544470e-20 1.134000000000000057e+02 3.020700074014724438e-20 2.624462736971969613e-20 3.633762198791709448e-21 9.116434285728178217e-24 9.822341006626691334e-21 2.491058335991643609e-22 5.510340214602926528e-22 1.549769519111885170e-21 1.880439108016836492e-21 0.000000000000000000e+00 4.433509302609906607e-22 4.763895346627573794e-21 7.481071235404085769e-22 2.877877015531387638e-20 1.135500110083658285e+02 3.109715604574433946e-20 2.624803150185120156e-20 3.404645273415993532e-21 9.059515823125151064e-24 9.816057178131603308e-21 2.482450972258421572e-22 5.496324923888068446e-22 1.548931426919804783e-21 1.696244799707326005e-21 0.000000000000000000e+00 4.521745194146364577e-22 4.177335714892725300e-21 7.508877610065201061e-22 2.864898623250949809e-20 1.137000000000000028e+02 3.226140504293958923e-20 2.625143986396906737e-20 3.650528779589828769e-21 9.002755555569008333e-24 9.809774372195238324e-21 2.473844944949853551e-22 5.482311690161546766e-22 1.548095503188369326e-21 1.665153801978278076e-21 0.000000000000000000e+00 4.543943792281236066e-22 4.081742113480148171e-21 7.536679903655895439e-22 2.866465439058614002e-20 1.138000000000000114e+02 3.178448731749476838e-20 2.625371489887520948e-20 3.788300123046574190e-21 8.966311111124414606e-24 9.805586061202650082e-21 2.468107213335392923e-22 5.472968848681086219e-22 1.547539317834447074e-21 1.545455459212567389e-21 0.000000000000000000e+00 4.611330725451108234e-22 5.255957830611824626e-21 7.555216126406499917e-22 2.886712094193010626e-20 1.139500109697230386e+02 3.053064534844815081e-20 2.625713164015459710e-20 3.942767274918663884e-21 8.911640446602928111e-24 9.799434403279440704e-21 2.459500048606407904e-22 5.458953561576563432e-22 1.546678203708543227e-21 1.674378327266507334e-21 0.000000000000000000e+00 4.529013440690359491e-22 4.963821119381137480e-21 7.583022493904700886e-22 2.884415506166901401e-20 1.141000000000000085e+02 3.160145899156328951e-20 2.626055260641529855e-20 3.795647014281004073e-21 8.857311111124006981e-24 9.793331465138241152e-21 2.450894217905628071e-22 5.444940324239707397e-22 1.545808878249640179e-21 1.818455267055077031e-21 0.000000000000000000e+00 4.624174278886628068e-22 5.506312443930648603e-21 7.610824794658309587e-22 2.893265247881842108e-20 1.142000000000000028e+02 3.215824212284637995e-20 2.626283604137963941e-20 3.610418555474810149e-21 8.821533333346095715e-24 9.789253667715855934e-21 2.445156620013467108e-22 5.435597482759248730e-22 1.545232997037553812e-21 1.538909335130140436e-21 0.000000000000000000e+00 4.517521108665660834e-22 4.566470019554280602e-21 7.629361017408911243e-22 2.872892751640302368e-20 1.143000000000000114e+02 3.002790180106855126e-20 2.626512157499056674e-20 3.553300482675261478e-21 8.785755555568178571e-24 9.785094988658645897e-21 2.439419056142294845e-22 5.426254641278788182e-22 1.544681347180473800e-21 1.927536925998000193e-21 0.000000000000000000e+00 4.469992443525985908e-22 5.452974620502729230e-21 7.647897240159516661e-22 2.889992646646518831e-20 1.144500109217993895e+02 3.012772641898319131e-20 2.626855405925054036e-20 3.657452653577293456e-21 8.732262807643306757e-24 9.778856528083208398e-21 2.430812148014166081e-22 5.412239358651695166e-22 1.543855531187964889e-21 1.831041357956915491e-21 0.000000000000000000e+00 4.480088310770338404e-22 5.405468355220627961e-21 7.675391035243451591e-22 2.889873931567087767e-20 1.146000000000000085e+02 2.981770849596829873e-20 2.627199076222320870e-20 3.411405609082734966e-21 8.679266666678885417e-24 9.772618957139408022e-21 2.422206571072314227e-22 5.398226116837408420e-22 1.543031900849347533e-21 1.914292644675530113e-21 0.000000000000000000e+00 4.578926711059153357e-22 5.096007126980250756e-21 7.702874204302514536e-22 2.881886853387905410e-20 1.147000000000000028e+02 3.050017062280112747e-20 2.627428468493925521e-20 3.129409598784801950e-21 8.643933333345423247e-24 9.768460296696665992e-21 2.416469145714170736e-22 5.388883275356949753e-22 1.542483923088375734e-21 1.744434531698863404e-21 0.000000000000000000e+00 4.613941428282477707e-22 5.439671789458604706e-21 7.721197651175293224e-22 2.883963100389672718e-20 1.148500108837609162e+02 3.061677289533776407e-20 2.627772974878368614e-20 2.967627238615416594e-21 8.591373992659488080e-24 9.762222147662630956e-21 2.407862449404028346e-22 5.374867996283730689e-22 1.541663623204529334e-21 1.645116188462196390e-21 0.000000000000000000e+00 4.659245835925008288e-22 5.660110717492867923e-21 7.748684815764610829e-22 2.886020290194265480e-20 1.150000000000000000e+02 3.064192378486685397e-20 2.628117902631611774e-20 3.000455847513722113e-21 8.539211111122821275e-24 9.756139158749076389e-21 2.399257082133731342e-22 5.360854750915569991e-22 1.540909432192307782e-21 1.669217487273190630e-21 0.000000000000000000e+00 4.530529173285436438e-22 4.927894767698033757e-21 7.776167991793631169e-22 2.873125759626675623e-20 1.151000000000000085e+02 3.314266070113679749e-20 2.628348132935240377e-20 3.146784239405100027e-21 8.504433333344919006e-24 9.752099346706860796e-21 2.393519799287175386e-22 5.351511909435110384e-22 1.540409083973542258e-21 1.652775364784305030e-21 0.000000000000000000e+00 4.572983429895829473e-22 3.805371005893768356e-21 7.794491438666412679e-22 2.857573918182999504e-20 1.152500108459864805e+02 3.231085995911147895e-20 2.628693895959344458e-20 3.390617018431079525e-21 8.452796276222715829e-24 9.746003610369762840e-21 2.384913320849693607e-22 5.337496633891096817e-22 1.539651936141005484e-21 1.635317862877639966e-21 0.000000000000000000e+00 4.610153595068036855e-22 4.432704943765699525e-21 7.821978596334151533e-22 2.869396979579036300e-20 1.154000000000000057e+02 3.086857078852234136e-20 2.629040079848917349e-20 3.518386643312791104e-21 8.401300000011223582e-24 9.739766656362714173e-21 2.376308169422595838e-22 5.323483384993730622e-22 1.538864508602589521e-21 1.921458232883087475e-21 0.000000000000000000e+00 4.543033915004892046e-22 5.946242810996548138e-21 7.849461779284751564e-22 2.900013186755526931e-20 1.155000000000000000e+02 3.105768783009357537e-20 2.629271147304105450e-20 3.560575004091585629e-21 8.367113513524617486e-24 9.735608452250196847e-21 2.370571033241487321e-22 5.314140543513271955e-22 1.538340475801498518e-21 1.907003313892770013e-21 0.000000000000000000e+00 4.513287210859877149e-22 5.390682859037020551e-21 7.867785226157530252e-22 2.889620118076748228e-20 1.156000000000000085e+02 3.234370929254985273e-20 2.629502423909380128e-20 3.507659704909713567e-21 8.334248648659630677e-24 9.731498041070710913e-21 2.364833934394695816e-22 5.304797702032811407e-22 1.537827931188898822e-21 2.087920580553697633e-21 0.000000000000000000e+00 4.497347530495755386e-22 4.232243712926621540e-21 7.886108673030311762e-22 2.870943774258544006e-20 1.157500107991355804e+02 3.068371287917274021e-20 2.629849755874017071e-20 3.422511497207497048e-21 8.284947802240849592e-24 9.725438626578158137e-21 2.356227737173983233e-22 5.290782430866004022e-22 1.537084648041551827e-21 1.930971799802355640e-21 0.000000000000000000e+00 4.751964054445745582e-22 6.164623855682525619e-21 7.914137027302248646e-22 2.903773823243856247e-20 1.159000000000000057e+02 3.334742151858215078e-20 2.630197508073752710e-20 3.571074543331499656e-21 8.235466666677308756e-24 9.719380064007522135e-21 2.347622864597344096e-22 5.276769177591431645e-22 1.536343239256094516e-21 2.191309231473493456e-21 0.000000000000000000e+00 4.641558636701077719e-22 5.566086748109760629e-21 7.942285599809158560e-22 2.895403577240115962e-20 1.160000000000000000e+02 3.314181429604476537e-20 2.630429620727249307e-20 3.683141736242017374e-21 8.202133333343868988e-24 9.715366354066297511e-21 2.341885917838337768e-22 5.267426336110972978e-22 1.535849914296265837e-21 1.839069720914044535e-21 0.000000000000000000e+00 4.624455613053742060e-22 4.797837158549277664e-21 7.961052665934372604e-22 2.880642529136042425e-20 1.161500107619452677e+02 3.238619065043722081e-20 2.630778206353503131e-20 3.766439576671267589e-21 8.152129746028616298e-24 9.709349673919717080e-21 2.333279952996174786e-22 5.253411068418796179e-22 1.535111350620863943e-21 1.827767933272001194e-21 0.000000000000000000e+00 4.591846767977393025e-22 5.180287619949130714e-21 7.989205284823580781e-22 2.888371918308133914e-20 1.163000000000000114e+02 2.963021352754655990e-20 2.631127211709603880e-20 3.798909266981694752e-21 8.102577777787984086e-24 9.703333853224317051e-21 2.324675311046600549e-22 5.239397811669592276e-22 1.534374667086333048e-21 1.909946518832121167e-21 0.000000000000000000e+00 4.565553244494399014e-22 5.098039889423141867e-21 8.017353864310022257e-22 2.887977655794659138e-20 1.164000000000000057e+02 2.987414358490626171e-20 2.631360159526464415e-20 3.780101528321149533e-21 8.069800000010102750e-24 9.699323015234413122e-21 2.318938520907156034e-22 5.230054970189133609e-22 1.533884496432284524e-21 1.719157972590165105e-21 0.000000000000000000e+00 4.693330502544670970e-22 4.676517881297013222e-21 8.036120930435237241e-22 2.879484726905424778e-20 1.165500107250102388e+02 3.162696322145325758e-20 2.631709997486021839e-20 3.647050175862205962e-21 8.020629817923258179e-24 9.693306360518043390e-21 2.310332795310736923e-22 5.216039705947738966e-22 1.533150670418564991e-21 1.905226172148680736e-21 0.000000000000000000e+00 4.613938650044042156e-22 5.261075803490463721e-21 8.064273542392822304e-22 2.889115766824592026e-20 1.167000000000000028e+02 2.949338324500238302e-20 2.632060254669331823e-20 3.308216717683628223e-21 7.972918918928710521e-24 9.687291265869767752e-21 2.301728390986156574e-22 5.202026445747753847e-22 1.532395212911932519e-21 1.770450773624847245e-21 0.000000000000000000e+00 4.708818783417202362e-22 3.481182852562236565e-21 8.092422128810883133e-22 2.857207815372363590e-20 1.168000000000000114e+02 3.391551195865492460e-20 2.632294036762768473e-20 3.243581679174191449e-21 7.941351351361037288e-24 9.683281045703109048e-21 2.295991762179769240e-22 5.192683604267293299e-22 1.531882062526013232e-21 1.875629303276572044e-21 0.000000000000000000e+00 4.693884627044902068e-22 4.468056197948080960e-21 8.111189194936100938e-22 2.870910614333810122e-20 1.169500106883278647e+02 3.205186113417133788e-20 2.632645125724429730e-20 3.369551281767774696e-21 7.893996695294109989e-24 9.677265315813930662e-21 2.287386282973258248e-22 5.178668343453075946e-22 1.531113739372006886e-21 1.994274564701974802e-21 0.000000000000000000e+00 4.640556117435810998e-22 4.953748815927181043e-21 8.139341800009480447e-22 2.881223437153612154e-20 1.171000000000000085e+02 3.209346064724469584e-20 2.632996633402911401e-20 3.526773964777593429e-21 7.847621621631005710e-24 9.671250515960384929e-21 2.278782123553406739e-22 5.164655079825914477e-22 1.530383905080728556e-21 1.924515716580345997e-21 0.000000000000000000e+00 4.672027033835793778e-22 5.302531329260744311e-21 8.166735075903406254e-22 2.888953068327877702e-20 1.172000000000000028e+02 3.345904350164669656e-20 2.633231248884224558e-20 3.637007769935959611e-21 7.816702702711989265e-24 9.667240382921280240e-21 2.273045660984487282e-22 5.155312238345455810e-22 1.529900050413538098e-21 1.785083246985511560e-21 0.000000000000000000e+00 4.648591917104047239e-22 5.092534588453990369e-21 8.184928757313750565e-22 2.885721042672729857e-20 1.173500106518955590e+02 3.427882924847081544e-20 2.633583587513927165e-20 3.516247991086859511e-21 7.770418362726499182e-24 9.661236228807349436e-21 2.264440435603062501e-22 5.141296980935049741e-22 1.529175710807898657e-21 1.887701024283795650e-21 0.000000000000000000e+00 4.607191661619745027e-22 5.848884520590884562e-21 8.212221217401210177e-22 2.899298733912668762e-20 1.175000000000000000e+02 3.270376827959811151e-20 2.633936344352685978e-20 3.338719351327827087e-21 7.724529729738728100e-24 9.655264438069190444e-21 2.255836528663849520e-22 5.127283713904076048e-22 1.528453268724824005e-21 1.726399790103523889e-21 0.000000000000000000e+00 4.579681848078580586e-22 6.167882367687356169e-21 8.239509801544786319e-22 2.902921134873232882e-20 1.176000000000000085e+02 3.040362211008507266e-20 2.634172427566118369e-20 3.594124855416147289e-21 7.693935135144035641e-24 9.651282980730395160e-21 2.250520885446788370e-22 5.118507956853695636e-22 1.527972604781870434e-21 1.980053298293670633e-21 0.000000000000000000e+00 4.542183223230012576e-22 5.592557047380840187e-21 8.257703482955133451e-22 2.896004747867945939e-20 1.177500106157107780e+02 3.134741683835691028e-20 2.634528039168744956e-20 4.047861004305418384e-21 7.648299500783566345e-24 9.645284795658303048e-21 2.243261550634370499e-22 5.106306819815808743e-22 1.527253057435197062e-21 1.800012425061732676e-21 0.000000000000000000e+00 4.487697932651999373e-22 6.676055775935588727e-21 8.284995936459248236e-22 2.923750492243002323e-20 1.179000000000000057e+02 3.318113750267636102e-20 2.634884056777865622e-20 4.055547238504036773e-21 7.603059459468083644e-24 9.639270515019882326e-21 2.236003289848893568e-22 5.094107409638933301e-22 1.526535413370228388e-21 1.881456192484001716e-21 0.000000000000000000e+00 4.503217039457079533e-22 5.410051549424419598e-21 8.312284527186168265e-22 2.898217605470515988e-20 1.180000000000000000e+02 3.293462988837298919e-20 2.635121672085551262e-20 3.977000170612063011e-21 7.572897297305832472e-24 9.635260729316924230e-21 2.231164132959772155e-22 5.085973893900679816e-22 1.526057952217018376e-21 2.024853154008053087e-21 0.000000000000000000e+00 4.504097695133290302e-22 5.325833143371874311e-21 8.330478208596512576e-22 2.896618945266674294e-20 1.181500105797710063e+02 2.974735510343953958e-20 2.635478500262919525e-20 3.662355101488554903e-21 7.528137406649212625e-24 9.629440039687322163e-21 2.223904925166865260e-22 5.073772759785958672e-22 1.525307483658203569e-21 1.935266166055422169e-21 0.000000000000000000e+00 4.582677772634627836e-22 7.099312490775702433e-21 8.357770655561861982e-22 2.929848438674242228e-20 1.183000000000000114e+02 2.991578029443857237e-20 2.635835733952129028e-20 3.438620262626055641e-21 7.483708108116383715e-24 9.623634073548225909e-21 2.216646789132084711e-22 5.061573346685916541e-22 1.524591465673674146e-21 1.892769692652156731e-21 0.000000000000000000e+00 4.572075676276768253e-22 7.440773690678815882e-21 8.385059252827551151e-22 2.935457426913829686e-20 1.184000000000000057e+02 3.011585872798243048e-20 2.636074159705842450e-20 3.447812259962874488e-21 7.454086486494679376e-24 9.619730088885764974e-21 2.211807717265259874e-22 5.053439830947662116e-22 1.524141756691257426e-21 1.971079210913577426e-21 0.000000000000000000e+00 4.675321450776978807e-22 7.020538086889011256e-21 8.402809975000837666e-22 2.925816873608758966e-20 1.185500105440737713e+02 3.016013155304715503e-20 2.636432203140839594e-20 3.533430264996985336e-21 7.410040154122669131e-24 9.613758154467156424e-21 2.204548639789056959e-22 5.041238699736381926e-22 1.523495207955275144e-21 2.141544420860262044e-21 0.000000000000000000e+00 4.853627808249866301e-22 5.792773315131857629e-21 8.429227369923920118e-22 2.901205467048557143e-20 1.187000000000000028e+02 3.123293756173708902e-20 2.636790651592249051e-20 3.736334639239430580e-21 7.366097297305234657e-24 9.607787151329330347e-21 2.197290631868753321e-22 5.029039283732899780e-22 1.522850253846924631e-21 1.904449727488153513e-21 0.000000000000000000e+00 4.932414806296818235e-22 5.707864481694031405e-21 8.455641051148575248e-22 2.900554251193135402e-20 1.188000000000000114e+02 3.032253373633121078e-20 2.637029886912796916e-20 3.748911133633068829e-21 7.336800000007854304e-24 9.603916668369651186e-21 2.192451647283535547e-22 5.020905767994645355e-22 1.522421090592152907e-21 1.865508057850720797e-21 0.000000000000000000e+00 5.008911075431179089e-22 6.415320607143457000e-21 8.473251409864489029e-22 2.915313887569893873e-20 1.189500105086166002e+02 3.148562032462846288e-20 2.637389144285733613e-20 3.618676287894019673e-21 7.293499669412461183e-24 9.598152022226202155e-21 2.185192703538850994e-22 5.008704639667279747e-22 1.521778556785536710e-21 1.788546097835460709e-21 0.000000000000000000e+00 5.051619338704692115e-22 1.135331173616691199e-20 8.499668798543435767e-22 3.060212724666576149e-20 1.191000000000000085e+02 3.451566949459592683e-20 2.637748806178885431e-20 3.643736459810039147e-21 7.250205405413023883e-24 9.592382662490705809e-21 2.177934827216113710e-22 4.996505220779883020e-22 1.521137621833413865e-21 1.951875511719378457e-21 0.000000000000000000e+00 5.156974598923155415e-22 1.282411951429183602e-20 8.526082486012226611e-22 3.119189378481518023e-20 1.192000000000000028e+02 3.299953231220993001e-20 2.637988850185366039e-20 3.719331275298641935e-21 7.221726315797018007e-24 9.588512200373765508e-21 2.173095932252534212e-22 4.988371705041628595e-22 1.520711141134414407e-21 2.077613034309979344e-21 0.000000000000000000e+00 5.320207197512336793e-22 6.646195927006171219e-21 8.543692844728138511e-22 2.921954096787680017e-20 1.193500104733971199e+02 3.116549279378398739e-20 2.638349320174000203e-20 3.969264561142460923e-21 7.180355006291590771e-24 9.582706465768274456e-21 2.165837125777061058e-22 4.976170579578844919e-22 1.520072635834419332e-21 1.856104974413361828e-21 0.000000000000000000e+00 5.504864611157793241e-22 5.763386253782187041e-21 8.570110227204810301e-22 2.905127349242332675e-20 1.195000000000000000e+02 3.132273923013776790e-20 2.638710194185889445e-20 4.256051405298502381e-21 7.138989473691522421e-24 9.576852537089573133e-21 2.158579384659660496e-22 4.963971157826866260e-22 1.519419923620681932e-21 2.109939382759309540e-21 0.000000000000000000e+00 5.774020669736923706e-22 6.034071401481010471e-21 8.596523920875876093e-22 2.916582206704682240e-20 1.196000000000000085e+02 3.142315276704533493e-20 2.638951045995708386e-20 4.336100657741444700e-21 7.111200000007233400e-24 9.572900578617320188e-21 2.153740581742106313e-22 4.955837642088611835e-22 1.518969772837551480e-21 1.840684499836670246e-21 0.000000000000000000e+00 5.813243219116994391e-22 5.626853449012206829e-21 8.614134279591789874e-22 2.907881249185216755e-20 1.197500104384129145e+02 3.379493310952128463e-20 2.639312727275264727e-20 4.382319039472671673e-21 7.069197077251505315e-24 9.566972178009095935e-21 2.146481916201962702e-22 4.943636519471273983e-22 1.518295736944880796e-21 1.822129017715180240e-21 0.000000000000000000e+00 5.994430818172475070e-22 6.281687731020113364e-21 8.640240734155330442e-22 2.922003096771421060e-20 1.199000000000000057e+02 1.370398202692662171e-19 2.639674812080357171e-20 4.227259122352852052e-21 7.027200000007011029e-24 9.561165079712075855e-21 2.139224314028000520e-22 4.931437094873849499e-22 1.517652298021417591e-21 2.466692054631893118e-21 0.000000000000000000e+00 6.338432657655135640e-22 2.613195063578417723e-20 8.665797805702181476e-22 3.871410998139252444e-20 1.200000000000000000e+02 4.367415385747086571e-19 2.639916470809240260e-20 4.097768486731486927e-21 7.000042105270097891e-24 9.557322815609713080e-21 2.134385605669051801e-22 4.923303579135595074e-22 1.517231183918037824e-21 3.139580077297419366e-21 0.000000000000000000e+00 7.392626828783185807e-22 1.119842338755025614e-19 8.682837039150443778e-22 1.155822911763472398e-19 1.201500104036616392e+02 2.520361376320163608e-19 2.640279362052430757e-20 3.875602960140718914e-21 6.959618249125380371e-24 9.551559117107731122e-21 2.127127084864621786e-22 4.911102459344756899e-22 1.516600737875952769e-21 1.860055033059838075e-21 0.000000000000000000e+00 6.499532940789885657e-22 3.730349426560696477e-20 8.708397662027030921e-22 4.692694261698440520e-20 1.203000000000000114e+02 3.241557628947307542e-20 2.640642656322688467e-20 3.663707478458702524e-21 6.919200000006725543e-24 9.545796247873928510e-21 2.119869625508500562e-22 4.898903031920831799e-22 1.515971903402894279e-21 1.547575950488174959e-21 0.000000000000000000e+00 5.984017832936466568e-22 9.017836675825542520e-21 8.733954739495234444e-22 2.982054268426346731e-20 1.204500103777496633e+02 3.144400521424068051e-20 2.641006454166073228e-20 3.470353540051113219e-21 6.879565679148557037e-24 9.540032854492211311e-21 2.112611215834101356e-22 4.886701914237549670e-22 1.515344508034710248e-21 1.787586315033409770e-21 0.000000000000000000e+00 5.844805140293495828e-22 7.573986235814484168e-21 8.759515357956619667e-22 2.940742213582652055e-20 1.206000000000000085e+02 2.830184105974036735e-20 2.641370654662183403e-20 3.577092921884139964e-21 6.839936842111789226e-24 9.534387826184458037e-21 2.105353866219475168e-22 4.874502484706069463e-22 1.514718727389600478e-21 1.772999114294288056e-21 0.000000000000000000e+00 5.645976688838602537e-22 6.640180483557752588e-21 8.785072439840023229e-22 2.919394559225400659e-20 1.207000000000000028e+02 2.984758307303284135e-20 2.641613723366639640e-20 3.749896014301043288e-21 6.813578947374882698e-24 9.530676473148596872e-21 2.100515329663802560e-22 4.866368968967815979e-22 1.514302361229402402e-21 2.151565320101362091e-21 0.000000000000000000e+00 5.557523396297140072e-22 7.127304920020006980e-21 8.802111673288285530e-22 2.935631544992490324e-20 1.208500103434004700e+02 3.182430192175806550e-20 2.641978728844921567e-20 3.589820003987751776e-21 6.774418352466032788e-24 9.525109139546755217e-21 2.093257071717624089e-22 4.854167854078329393e-22 1.513679045221427037e-21 1.989702442381194334e-21 0.000000000000000000e+00 5.376775987368314066e-22 6.130602585617489737e-21 8.827672285896831718e-22 2.909986199369660464e-20 1.210000000000000000e+02 3.214585217634642609e-20 2.642344136476161221e-20 3.281313898897996906e-21 6.735263157901005062e-24 9.519385883535282388e-21 2.085999872048161564e-22 4.841968421753053643e-22 1.513026479122550192e-21 1.760524596815218144e-21 0.000000000000000000e+00 5.285003367436103931e-22 6.421600988679609817e-21 8.853229373633074316e-22 2.911272492416055690e-20 1.211000000000000085e+02 3.166833933702118408e-20 2.642588009659378808e-20 3.394335593348261609e-21 6.709326315795677558e-24 9.515544019641830113e-21 2.081161437449245382e-22 4.833834906014798278e-22 1.512587098847642294e-21 2.138436783155929187e-21 0.000000000000000000e+00 5.195099707508054349e-22 5.975504783596310313e-21 8.870181571304164181e-22 2.905676218678919875e-20 1.212500103092779256e+02 3.207489514126516549e-20 2.642954221438468034e-20 3.612041972170540933e-21 6.670797352149462063e-24 9.509783631530107730e-21 2.073903335433765994e-22 4.821633793900675483e-22 1.511931814251273703e-21 2.019701046600992699e-21 0.000000000000000000e+00 5.139413600403143358e-22 6.237560632990486069e-21 8.894975289308648819e-22 2.913085485731484133e-20 1.214000000000000057e+02 3.245572881456871760e-20 2.643320834870014545e-20 3.364089189220036701e-21 6.632273684216539931e-24 9.504062938129566059e-21 2.066646289992240918e-22 4.809434358800035943e-22 1.511314176302293621e-21 2.056629344409546146e-21 0.000000000000000000e+00 5.070513782178228385e-22 6.513762013103465974e-21 8.919765599476286157e-22 2.916553593716345096e-20 1.215500102838333873e+02 3.292161621024663182e-20 2.643687950497748405e-20 3.144409368785370546e-21 6.594092128001872209e-24 9.498341714363861876e-21 2.059388307778175071e-22 4.797233248755448065e-22 1.510697993718740979e-21 1.885335848135067654e-21 0.000000000000000000e+00 4.978124131212919836e-22 7.246577477707861783e-21 8.944559313275295875e-22 2.930331799907968728e-20 1.217000000000000028e+02 3.374612664393765612e-20 2.644055467402084994e-20 3.117274268363988938e-21 6.556042105268989775e-24 9.492724213505358866e-21 2.052131380915219566e-22 4.785033811585273608e-22 1.510090582732133686e-21 2.149744915131160470e-21 0.000000000000000000e+00 4.967800925022383350e-22 6.849114096207296349e-21 8.969349627648408133e-22 2.922441937295017124e-20 1.218000000000000114e+02 3.216427565228938885e-20 2.644300746279516609e-20 3.286330478633083216e-21 6.530673684216298507e-24 9.489013243044395019e-21 2.047293131739208752e-22 4.776900295847018242e-22 1.509714528258311211e-21 2.130977428523160537e-21 0.000000000000000000e+00 5.065082967655499711e-22 6.935584863848201867e-21 8.985877637039117966e-22 2.926313003268381565e-20 1.219500102501020677e+02 3.251198538783052535e-20 2.644669065867555755e-20 3.834136268155597779e-21 6.493165863927594932e-24 9.483446400567486085e-21 2.040035313197897223e-22 4.764699188545973054e-22 1.509151497118577303e-21 1.861830181389311574e-21 0.000000000000000000e+00 4.912635667302899784e-22 8.289070663400644721e-21 9.010671345263010004e-22 2.966206989975283699e-20 1.221000000000000085e+02 3.288180889449554083e-20 2.645037786230427277e-20 3.966852684679446856e-21 6.455747368426654492e-24 9.477746664480507126e-21 2.032778548451704744e-22 4.752499748632255907e-22 1.508556312862826595e-21 2.199239904529250221e-21 0.000000000000000000e+00 4.805389470866363508e-22 7.182104760232146610e-21 9.035461665211239942e-22 2.941420843175371800e-20 1.222000000000000028e+02 3.161167398250666495e-20 2.645283867134006536e-20 3.917743300756783337e-21 6.430800000005546656e-24 9.473932891663228696e-21 2.027940409422446050e-22 4.744366232894002422e-22 1.508156770759031495e-21 2.036590793330365465e-21 0.000000000000000000e+00 4.786721246762453656e-22 7.041859842714364765e-21 9.051989674601946014e-22 2.936292881830398336e-20 1.223500102165913290e+02 3.196848960993734794e-20 2.645653389341616342e-20 3.833374276961940365e-21 6.394797548023541196e-24 9.468238362715037025e-21 2.020682759212776617e-22 4.732165128318558117e-22 1.507563650842959684e-21 1.955434172836251225e-21 0.000000000000000000e+00 4.781482996039646194e-22 6.873676577298076053e-21 9.076783377287181386e-22 2.930787768603617290e-20 1.225000000000000000e+02 2.920161723215278137e-20 2.646023311821572267e-20 3.771191289824113355e-21 6.358800000005378617e-24 9.462713416941615075e-21 2.013426161329968902e-22 4.719965685679240087e-22 1.507005465274815018e-21 2.147674323083579679e-21 0.000000000000000000e+00 4.791985264347833686e-22 7.013416261839679545e-21 9.101502481311489558e-22 2.934794215109858438e-20 1.226500101916017087e+02 3.045150882901745638e-20 2.646393735112571678e-20 3.895445390080570099e-21 6.322671216775411408e-24 9.457187648381305196e-21 2.006168640535072731e-22 4.707764583136329899e-22 1.506448517353542608e-21 2.068188158053378034e-21 0.000000000000000000e+00 4.767360999931888231e-22 7.222691615831176280e-21 9.125507034342341835e-22 2.941069329970718229e-20 1.228000000000000114e+02 3.183180666993634127e-20 2.646764558298586306e-20 3.994421865740557078e-21 6.286357894742058775e-24 9.451635491272358643e-21 1.998912171025234545e-22 4.695565138464476811e-22 1.505892959984223559e-21 2.155787841961876077e-21 0.000000000000000000e+00 4.704326955785659142e-22 5.058481488555214779e-21 9.149508325663561717e-22 2.897666946507520720e-20 1.229000000000000057e+02 3.101800312851515966e-20 2.647012040593730524e-20 3.908600774759169296e-21 6.262147368426218638e-24 9.447924810872631260e-21 1.994074232516066672e-22 4.687431622726222386e-22 1.505523294463181705e-21 1.790058073617007295e-21 0.000000000000000000e+00 4.710356436511275642e-22 7.419129778042056114e-21 9.165510273780917850e-22 2.944560367124750355e-20 1.230500101584717498e+02 3.191053984526512080e-20 2.647383664152305294e-20 3.728666938346576981e-21 6.226571993878846356e-24 9.442358598577268799e-21 1.986816888647071613e-22 4.675230522877943037e-22 1.504969856707766692e-21 2.048776221960850308e-21 0.000000000000000000e+00 4.689374974765423067e-22 6.460241508811744442e-21 9.189514821510330101e-22 2.921377626024980862e-20 1.232000000000000028e+02 3.233227761040443186e-20 2.647756622065739896e-20 3.434762275447689146e-21 6.191651282056295071e-24 9.436828435661743320e-21 1.980228007088613055e-22 4.663955692088159900e-22 1.504417812662672726e-21 2.011343983050432354e-21 0.000000000000000000e+00 4.744686377223899690e-22 6.090057822872361297e-21 9.213516118132986248e-22 2.909709956533960052e-20 1.233500101337652950e+02 3.176142060505747084e-20 2.648130735060772891e-20 3.247616668961155251e-21 6.156725845784711070e-24 9.431302952299537304e-21 1.974110746984735500e-22 4.653333889127762554e-22 1.503867014316347708e-21 2.162193795590331190e-21 0.000000000000000000e+00 4.713317892071808924e-22 6.093896639564097354e-21 9.237520661908887501e-22 2.908881947415331398e-20 1.235000000000000000e+02 2.989174369457922221e-20 2.648505238219304732e-20 3.186393468355732449e-21 6.122235897440761681e-24 9.425778542983244050e-21 1.967994345585745431e-22 4.642713521255189531e-22 1.503302499535613908e-21 2.015377706371647362e-21 0.000000000000000000e+00 4.702347526937126603e-22 5.807757032299171761e-21 9.261521962485056527e-22 2.901450164341272177e-20 1.236000000000000085e+02 3.100946448555323657e-20 2.648755168612702010e-20 3.417381996258321829e-21 6.099261538466352531e-24 9.422095382371881039e-21 1.963916487204873402e-22 4.635632797644199095e-22 1.502911744331856302e-21 2.064533977182850795e-21 0.000000000000000000e+00 4.829553777804213588e-22 6.456142986938251998e-21 9.277523910602414540e-22 2.918210188011084211e-20 1.237500101010096927e+02 3.261104620717183751e-20 2.649130456493172682e-20 3.793723118910998791e-21 6.064797720802556239e-24 9.416570289498046956e-21 1.957799315028386828e-22 4.625010997003135798e-22 1.502326652960153171e-21 2.046751737934215772e-21 0.000000000000000000e+00 4.822050585087102349e-22 5.217901373437647458e-21 9.301528449136778960e-22 2.898061423310021083e-20 1.239000000000000057e+02 2.974232783677449314e-20 2.649506134043631680e-20 3.540864875124971285e-21 6.030953846158516870e-24 9.411045932688885827e-21 1.951682999685601507e-22 4.614390626811228726e-22 1.501765629151217636e-21 2.438971463837614317e-21 0.000000000000000000e+00 4.721255102306356541e-22 5.199342369667438915e-21 9.325529754954484819e-22 2.897713647901895839e-20 1.240500100765816143e+02 3.097762210834620640e-20 2.649882302214933804e-20 3.344467430937047731e-21 5.997105418622083992e-24 9.405520857041944401e-21 1.945565894880970747e-22 4.603768827899849884e-22 1.501220978134760339e-21 2.077939194413794710e-21 0.000000000000000000e+00 4.807913538085993365e-22 5.868814825127637406e-21 9.348792357858323610e-22 2.905522989649104469e-20 1.242000000000000028e+02 3.097920573243451865e-20 2.650258859685656977e-20 3.376877881552310708e-21 5.963446153850685616e-24 9.400001990655710823e-21 1.939449645535801592e-22 4.593148455978258358e-22 1.500677728759369442e-21 2.403548062674873526e-21 0.000000000000000000e+00 4.723299254371822377e-22 7.919622123712915697e-21 9.372019768906112621e-22 2.956772055716113533e-20 1.243000000000000114e+02 3.236812659662518743e-20 2.650510159131919957e-20 3.266570928430998121e-21 5.941189743594228290e-24 9.396345969137514969e-21 1.935371890893983218e-22 4.586067732367267921e-22 1.500316276949559123e-21 1.760168172167505442e-21 0.000000000000000000e+00 4.780386849723043362e-22 6.652309948463039503e-21 9.387505749909649796e-22 2.919661226724928525e-20 1.244500100441940447e+02 3.110007373694054832e-20 2.650887499858280914e-20 2.900729359548427569e-21 5.907802892732515506e-24 9.390861589700854651e-21 1.929254877879608070e-22 4.575445935749163829e-22 1.499775172318866683e-21 2.154314956393530890e-21 0.000000000000000000e+00 4.833219404257161972e-22 7.115794046345050312e-21 9.410736276856935082e-22 2.929528479440853333e-20 1.246000000000000085e+02 3.019504492916515045e-20 2.651265229389398045e-20 2.803115613032252651e-21 5.874635897440249940e-24 9.385412886153236979e-21 1.923138718532036020e-22 4.564825561534297553e-22 1.499235472465148487e-21 2.266282287197720779e-21 0.000000000000000000e+00 4.742742104000666711e-22 8.301923636223998098e-21 9.433963692920257561e-22 2.960625221986644563e-20 1.247500100200396815e+02 3.232104966589149748e-20 2.651643448656350762e-20 2.932055351661455727e-21 5.841710621246863984e-24 9.380033250926808093e-21 1.917021775873169376e-22 4.554203766626497304e-22 1.498697034348985901e-21 2.075238133285620161e-21 0.000000000000000000e+00 4.749461189646600111e-22 6.793599796940629200e-21 9.457194216127003213e-22 2.921939638623296373e-20 1.249000000000000057e+02 3.122319574144197141e-20 2.652022056356635035e-20 3.299309238226604842e-21 5.808789743593971158e-24 9.374654358002841335e-21 1.910905685566933240e-22 4.543583390701327184e-22 1.498160003356949635e-21 2.184185474228785072e-21 0.000000000000000000e+00 4.794480709969873143e-22 6.467063848463089234e-21 9.480421635930865326e-22 2.919420137917307101e-20 1.250000000000000000e+02 3.122593599393280548e-20 2.652274722132506298e-20 3.550653081591827320e-21 5.787087179491366370e-24 9.371019405517693843e-21 1.906828039352679226e-22 4.536502667090337688e-22 1.497785006366698419e-21 1.982918264888969239e-21 0.000000000000000000e+00 4.841201603335213774e-22 6.290705359002255675e-21 9.495907616934400621e-22 2.917200452121750461e-20 1.251500099880139913e+02 3.072530255786943332e-20 2.652654111617620935e-20 3.835043375767027523e-21 5.754623479521095416e-24 9.365535266071373039e-21 1.900711192582132554e-22 4.525880874450187353e-22 1.497212192580866938e-21 2.067502813925517514e-21 0.000000000000000000e+00 4.840667263733526903e-22 6.234721506755038759e-21 9.519138135181654733e-22 2.920355480470037068e-20 1.253000000000000114e+02 2.918539144919341470e-20 2.653033889040268964e-20 4.136986963993199877e-21 5.722164102568161683e-24 9.360051880595428407e-21 1.894595196453295881e-22 4.515260496257366379e-22 1.496659685734242534e-21 2.442532464546178926e-21 0.000000000000000000e+00 4.940507543906493979e-22 6.541038292869226862e-21 9.542365559945010267e-22 2.934228532289695456e-20 1.254500099641287534e+02 3.082792371157169418e-20 2.653414155310888342e-20 4.496348626601141961e-21 5.690131207656535040e-24 9.354712028730920644e-21 1.888478423204924297e-22 4.504638705308464654e-22 1.496174895899422676e-21 2.218247713703894838e-21 0.000000000000000000e+00 4.894598148091677434e-22 7.517333588867616006e-21 9.565105309082930891e-22 2.961167032586100320e-20 1.256000000000000085e+02 3.095813190788634787e-20 2.653794809146774200e-20 4.330608965155812328e-21 5.658133333337275790e-24 9.349372925823346648e-21 1.882362499346691307e-22 4.494018325424396011e-22 1.495691283259551850e-21 2.012431717382625847e-21 0.000000000000000000e+00 4.867970052648843577e-22 6.309276669345925562e-21 9.587648525025260989e-22 2.929018967533370466e-20 1.257000000000000028e+02 3.031858177665911702e-20 2.654048838521465642e-20 4.046667693455486013e-21 5.636800000003905783e-24 9.345813300126778323e-21 1.878284966535221778e-22 4.486937601813406515e-22 1.495369472182524086e-21 2.081837511093864445e-21 0.000000000000000000e+00 4.942427959715043914e-22 6.288527842521438679e-21 9.602678334046495051e-22 2.925125735342386902e-20 1.258500099324588888e+02 3.116061427377830336e-20 2.654430272666939087e-20 3.756483262071084097e-21 5.606047963849776165e-24 9.340473815941274876e-21 1.872168293526489611e-22 4.476315813106959627e-22 1.494887652689564331e-21 2.078151444911831657e-21 0.000000000000000000e+00 4.907435305982171729e-22 6.728199359762043325e-21 9.625224540407948208e-22 2.931177968471613996e-20 1.260000000000000000e+02 3.103374396290996698e-20 2.654812093880767120e-20 3.563046303870274264e-21 5.575300000003791071e-24 9.335135060367867377e-21 1.866052468282275042e-22 4.465695430980436146e-22 1.494407012670903170e-21 2.295756379858460908e-21 0.000000000000000000e+00 4.925995958798923981e-22 6.509925446016527952e-21 9.647767761110197236e-22 2.925633906483834708e-20 1.261500099088382996e+02 3.110570099533300422e-20 2.655194403051890408e-20 3.504791565244610628e-21 5.544697998418397605e-24 9.329733555014858111e-21 1.859935872159553504e-22 4.455073643946497668e-22 1.493927425965613898e-21 2.073813159514384990e-21 0.000000000000000000e+00 4.875436957788250536e-22 5.806833710744776369e-21 9.670313963921522036e-22 2.908592463011706888e-20 1.263000000000000114e+02 3.230378464040108836e-20 2.655577098918271416e-20 3.576364675464926240e-21 5.514400000003675439e-24 9.324291444636627324e-21 1.853820122615196301e-22 4.444453260147464837e-22 1.493449020440785750e-21 2.002196020287197655e-21 0.000000000000000000e+00 4.917092559567659799e-22 6.607408315255811577e-21 9.692857188173901302e-22 2.926178417211033923e-20 1.264500098853297771e+02 2.990105786702224930e-20 2.655960282359381256e-20 3.820957364086059529e-21 5.484098003167006490e-24 9.318862439280711173e-21 1.847703604884275552e-22 4.433831474778100651e-22 1.492966730160064426e-21 2.019120997618540888e-21 0.000000000000000000e+00 4.868747202826499896e-22 5.704419146375562807e-21 9.715403387451938348e-22 2.910517665202103486e-20 1.266000000000000085e+02 2.993635766410322534e-20 2.656343852122300168e-20 3.905182577529510435e-21 5.453589743593310948e-24 9.313523761802133401e-21 1.841587932574540871e-22 4.423211089314494468e-22 1.492453515861278596e-21 2.090883991044921129e-21 0.000000000000000000e+00 4.890858884298180336e-22 6.039697035768691382e-21 9.737946615237603487e-22 2.919079767249311324e-20 1.267500098619325684e+02 2.975995577093760679e-20 2.656727909076876833e-20 3.841864850195486815e-21 5.422972346132152144e-24 9.308184370205537493e-21 1.835471494781550984e-22 4.412589305601822179e-22 1.491941331716013337e-21 2.177683158532523928e-21 0.000000000000000000e+00 4.946018883447895649e-22 6.638542010124268413e-21 9.760492810999086177e-22 2.932041446868936076e-20 1.269000000000000057e+02 3.130415797807040734e-20 2.657112351979467555e-20 3.492347858736500454e-21 5.392440000003465775e-24 9.302869398656247941e-21 1.829355901282148330e-22 4.401968918481524100e-22 1.491452556664070233e-21 2.583414576167921360e-21 0.000000000000000000e+00 4.973531766069498463e-22 6.288376527433309474e-21 9.782538227745386124e-22 2.923419619567406973e-20 1.270000000000000000e+02 2.951262310852444668e-20 2.657368906481847732e-20 3.312143623452985127e-21 5.372840000003433137e-24 9.299336540797831407e-21 1.825278593347034201e-22 4.394888194870534604e-22 1.491137190872684524e-21 1.987007332574342828e-21 0.000000000000000000e+00 4.805003518368730993e-22 6.076864020482524499e-21 9.797092638754686685e-22 2.912260422969295473e-20 1.271500098309079902e+02 2.903175954445634070e-20 2.657754126942773425e-20 3.360600072219054234e-21 5.343438073145416390e-24 9.294036924113284941e-21 1.819162264615314857e-22 4.384266413354626157e-22 1.490665048065609762e-21 2.126487495997150369e-21 0.000000000000000000e+00 4.833470790677014973e-22 6.794735817478090359e-21 9.818925686099390251e-22 2.929802038886822479e-20 1.273000000000000114e+02 3.075588911720469628e-20 2.658139732852782664e-20 3.612580255510584108e-21 5.314070000003332642e-24 9.288837477555231616e-21 1.813046778720810603e-22 4.373646024037563295e-22 1.490194092160270634e-21 2.369445181780334732e-21 0.000000000000000000e+00 4.840347840757432775e-22 5.974304298575970578e-21 9.840755871782586489e-22 2.916947144416967449e-20 1.274500098077673726e+02 2.916976792903414146e-20 2.658525825058673160e-20 4.112131139594947364e-21 5.285118107104183445e-24 9.283673720825304419e-21 1.806930533699252610e-22 4.363024244160179245e-22 1.489724200823539177e-21 2.187223839204341909e-21 0.000000000000000000e+00 4.795415973836916431e-22 6.509218973115863925e-21 9.862588915759308780e-22 2.933719548515208754e-20 1.276000000000000085e+02 3.103562727014348470e-20 2.658912302339050517e-20 4.217713002330139095e-21 5.256170000003236655e-24 9.278497841548063218e-21 1.800815130458812435e-22 4.352403853204592926e-22 1.489250547887519181e-21 2.146061371606019226e-21 0.000000000000000000e+00 4.751665179602457009e-22 6.035048450799203697e-21 9.884419104810486293e-22 2.924946215794526121e-20 1.277500097847354397e+02 3.062052869154539661e-20 2.659299265530582055e-20 4.130457235707739178e-21 5.227398140903456303e-24 9.273237984583671301e-21 1.794698970838103222e-22 4.341782074958036136e-22 1.488745770257848665e-21 1.982428898926336253e-21 0.000000000000000000e+00 4.692065390082266059e-22 7.081725121864108455e-21 9.906252145435046642e-22 2.946116660362819901e-20 1.279000000000000057e+02 5.288489558313913635e-20 2.659686613421663723e-20 4.016872410405656620e-21 5.198900000003143044e-24 9.267978833943272692e-21 1.788583651974200625e-22 4.331161682371623498e-22 1.488242164601198158e-21 2.266145961235010375e-21 0.000000000000000000e+00 4.677307351183166262e-22 4.430184316993575665e-21 9.928082337838386097e-22 2.894520420239226287e-20 1.280000000000000000e+02 9.510942957559617383e-20 2.659945103874498270e-20 3.944925775811613222e-21 5.179900000003113159e-24 9.264461991703542724e-21 1.784506530811039728e-22 4.324080958760633062e-22 1.487916929263121926e-21 2.587542723954003951e-21 0.000000000000000000e+00 4.767965525343764993e-22 6.049147142104376451e-21 9.942636748847684778e-22 2.925507972394727028e-20 1.281500097541939454e+02 4.263269416810322419e-20 2.660333227197614825e-20 3.731614690625535913e-21 5.151793332892373900e-24 9.259162845702060400e-21 1.778390487768889548e-22 4.313459182676634169e-22 1.487452278515027888e-21 2.063695562014655429e-21 0.000000000000000000e+00 4.792815025963058851e-22 6.936157579205574751e-21 9.964469785027112298e-22 2.938394626836136277e-20 1.283000000000000114e+02 2.908106169043249279e-20 2.660721734719843662e-20 3.546761210653459664e-21 5.124282926832286998e-24 9.253864595155422372e-21 1.772275284168506819e-22 4.302838787927661753e-22 1.486988820355961110e-21 2.140719320877430004e-21 0.000000000000000000e+00 4.847681975533009460e-22 5.601428782089808181e-21 9.986286318675766648e-22 2.908223166774839913e-20 1.284500097314126208e+02 3.195064259387511431e-20 2.661110727253633227e-20 3.347990960533809140e-21 5.096768946826809525e-24 9.248693327563109144e-21 1.766159330656222896e-22 4.292217013456746738e-22 1.486526435356423602e-21 2.370802069018923142e-21 0.000000000000000000e+00 4.843558590811300382e-22 7.157974763349372574e-21 1.000806081951146327e-21 2.941797293936914870e-20 1.285999999999999943e+02 3.090062582988597400e-20 2.661500103610817137e-20 3.426036625897272402e-21 5.069100000002936047e-24 9.243569126776469879e-21 1.760044215638452403e-22 4.281596617094693265e-22 1.486065244627726601e-21 2.205478750021771263e-21 0.000000000000000000e+00 4.750994891750278663e-22 8.069961627550272160e-21 1.002983249524174389e-21 2.965101015623727928e-20 1.287500097087375082e+02 3.228865744444819962e-20 2.661889964593218122e-20 3.663889554205279834e-21 5.041348203886454202e-24 9.238421046272490432e-21 1.753928353508482415e-22 4.270974844229338024e-22 1.485605129607179582e-21 2.132904390750713152e-21 0.000000000000000000e+00 4.783895273893266268e-22 6.533971395359006217e-21 1.005160699278606009e-21 2.929573039343406562e-20 1.289000000000000057e+02 3.050260704324447483e-20 2.662280209022966001e-20 3.921383798289957482e-21 5.013600000002851072e-24 9.233122821868843757e-21 1.747813328960128009e-22 4.260354446261721956e-22 1.485146210535634006e-21 2.057270310971737680e-21 0.000000000000000000e+00 4.848690551693774380e-22 6.055162963522811207e-21 1.007337867180772489e-21 2.922270222646332180e-20 1.290500096861677832e+02 3.190396996971942617e-20 2.662671906601567594e-20 3.957112450183462790e-21 4.986298237120273412e-24 9.227823873730129021e-21 1.742432238802471508e-22 4.250794738710947204e-22 1.484724266234596275e-21 2.220898342435394343e-21 0.000000000000000000e+00 4.935094427343984205e-22 7.620269276912079849e-21 1.009515316607595715e-21 2.960528147008925482e-20 1.292000000000000171e+02 3.157913320460459689e-20 2.663064266666184221e-20 3.602803648408940732e-21 4.959000000002765820e-24 9.222630063496135795e-21 1.737268222251802236e-22 4.241549030411713410e-22 1.484283257377607941e-21 2.418019057736295992e-21 0.000000000000000000e+00 4.911734092031098057e-22 5.254163825443490915e-21 1.011692484837370778e-21 2.905786063523651859e-20 1.293500096637027923e+02 3.154286696293822118e-20 2.663457104208636715e-20 3.493667425266720314e-21 4.932017815157361377e-24 9.217505361253153364e-21 1.732103561745904656e-22 4.232302129347067077e-22 1.483828618696719230e-21 2.274198356061459654e-21 0.000000000000000000e+00 4.832747763284436257e-22 5.831668195760011109e-21 1.013869933938105476e-21 2.914483158219766435e-20 1.295000000000000000e+02 3.134403986566877986e-20 2.663850317754166472e-20 3.588591339210937772e-21 4.905678048783177749e-24 9.212381613290617946e-21 1.726939589098502825e-22 4.223056419663046864e-22 1.483374978867302734e-21 2.155718896004974317e-21 0.000000000000000000e+00 4.868167517816851686e-22 5.838289440187138060e-21 1.016047102493968502e-21 2.915075461786941223e-20 1.296500096413417111e+02 3.028315243826643673e-20 2.664244008392288329e-20 3.676258676401443992e-21 4.879334892254838652e-24 9.207295680737221814e-21 1.721774974446400319e-22 4.213809519976781916e-22 1.482958547110643948e-21 2.078866337710106545e-21 0.000000000000000000e+00 4.943875830950149291e-22 6.467172993196357759e-21 1.018224551270123631e-21 2.929065370019198624e-20 1.298000000000000114e+02 3.257015894835854797e-20 2.664638074663098019e-20 3.650535869719275248e-21 4.853258536587976735e-24 9.202210436593143648e-21 1.716611046513504436e-22 4.204563808914378438e-22 1.482543131132856455e-21 2.307918931336830818e-21 0.000000000000000000e+00 4.908799414963961222e-22 6.932745991796255862e-21 1.020410443041080132e-21 2.941279589077460984e-20 1.299000000000000057e+02 3.117353938038907022e-20 2.664901039109362480e-20 3.486910880061599442e-21 4.835990243905025262e-24 9.198817509624840639e-21 1.713168219394587530e-22 4.198399605331489433e-22 1.482266704342213005e-21 2.133691431340403892e-21 0.000000000000000000e+00 4.904934625344462789e-22 5.216078834187407352e-21 1.021880048383139026e-21 2.902402865040856984e-20 1.300500096116874431e+02 3.156334502011634016e-20 2.665295866032140384e-20 3.348407773487338107e-21 4.810086145106279637e-24 9.193693196556466056e-21 1.708003667150369018e-22 4.189152707473174153e-22 1.481852840793731127e-21 2.141157788928720061e-21 0.000000000000000000e+00 4.991153504775356947e-22 6.951580492784073608e-21 1.024084597650099518e-21 2.937215521080749518e-20 1.302000000000000171e+02 3.342204295073422674e-20 2.665691068093274975e-20 3.399206254774060078e-21 4.784419512197631910e-24 9.188569587495646961e-21 1.702839800132628121e-22 4.179906994582821006e-22 1.481439994686165923e-21 2.251084654342095709e-21 0.000000000000000000e+00 4.915452219908234990e-22 8.255451225930437385e-21 1.026288864409316274e-21 2.972353350610225656e-20 1.303500095895662128e+02 3.251195157821899858e-20 2.666086746346410041e-20 3.655687905578644194e-21 4.758954469676113875e-24 9.183463313998743968e-21 1.697675295672366877e-22 4.170660098088104094e-22 1.481011085958329813e-21 2.186178250358971329e-21 0.000000000000000000e+00 5.026536114607512850e-22 8.174882219201491605e-21 1.028493413351181860e-21 2.972905349917057233e-20 1.305000000000000000e+02 3.130225102949966556e-20 2.666482799366795556e-20 3.986802784309405259e-21 4.733492682929269899e-24 9.178378217588292104e-21 1.692511475339105531e-22 4.161414383834153991e-22 1.480563788375838775e-21 2.112276009122667502e-21 0.000000000000000000e+00 4.949259825940615743e-22 7.459414572160125998e-21 1.030697680435492957e-21 2.957965603920760220e-20 1.306500095675465332e+02 3.071005874702870626e-20 2.666879328192499650e-20 3.899310489214321207e-21 4.708261809155572299e-24 9.173292621284441887e-21 1.687347019524085796e-22 4.152167488696773823e-22 1.480117380567485057e-21 1.946635804345896400e-21 0.000000000000000000e+00 5.087709587481155547e-22 6.996380381056938231e-21 1.032902229053756421e-21 2.944545067054803821e-20 1.308000000000000114e+02 3.056422918101236302e-20 2.667276231414045525e-20 3.878969299136519786e-21 4.683092682929198042e-24 9.168207723723759092e-21 1.682183246754080302e-22 4.142921773085485564e-22 1.479703524163538037e-21 2.201038235481593323e-21 0.000000000000000000e+00 5.199236059838262239e-22 6.388507196560141135e-21 1.035106496461670205e-21 2.932452087501118730e-20 1.309500095456277506e+02 3.139163842422506060e-20 2.667673610053804080e-20 4.085533032867439173e-21 4.657949645650053346e-24 9.163122193400073510e-21 1.677018840466938466e-22 4.133674879299224716e-22 1.479295433941179356e-21 1.975042611002701388e-21 0.000000000000000000e+00 5.193066085734858263e-22 6.472529388774100372e-21 1.037311044757813986e-21 2.935694286386189268e-20 1.310999999999999943e+02 3.065651033555552103e-20 2.668071362717694520e-20 3.855257704281718829e-21 4.633219512197425157e-24 9.158071142173980917e-21 1.671855116160596809e-22 4.124429162336819019e-22 1.478888364932937858e-21 1.861194571776752519e-21 0.000000000000000000e+00 5.139272686364444606e-22 5.825641945309412602e-21 1.039515312487847076e-21 2.918434192705698076e-20 1.312500095238091831e+02 3.143904795969878458e-20 2.668469590412271645e-20 3.479590526872552939e-21 4.608486234613244015e-24 9.153112530615594421e-21 1.666690760305980158e-22 4.115182269895497681e-22 1.478482214372556788e-21 1.843058122047497145e-21 0.000000000000000000e+00 5.269813031176028688e-22 6.499846507086532815e-21 1.041719860463344211e-21 2.928055376653893344e-20 1.314000000000000057e+02 2.971099500408740671e-20 2.668868191758973444e-20 3.678218846687274024e-21 4.583853658538822447e-24 9.148154602324702200e-21 1.661527085386013447e-22 4.105936551588150592e-22 1.478077086261733702e-21 2.079175918579459590e-21 0.000000000000000000e+00 5.268199346157236337e-22 7.726600355067084438e-21 1.043868897207590962e-21 2.961883223276516415e-20 1.315500095020901199e+02 3.090209471737141930e-20 2.669267267748417345e-20 3.917190609710878767e-21 4.559413086003132376e-24 9.143119985833166262e-21 1.656362780891272531e-22 4.096689660485637386e-22 1.477672878561427946e-21 2.265307089689727764e-21 0.000000000000000000e+00 5.139022577075745277e-22 6.474246599890764472e-21 1.046016034760353442e-21 2.936365665751378928e-20 1.317000000000000171e+02 3.103445219613334270e-20 2.669666717017684704e-20 4.070136919017533879e-21 4.534975609758267727e-24 9.138035269885966455e-21 1.651199156303393242e-22 4.087443940839481696e-22 1.477269694543236970e-21 2.453525378646384502e-21 0.000000000000000000e+00 5.129579682165369596e-22 5.745693152240912774e-21 1.048162900299753732e-21 2.924983712667767170e-20 1.318500094804699074e+02 3.207887746976904432e-20 2.670066640541334906e-20 3.889481780379088400e-21 4.511055653071156612e-24 9.132950110543087450e-21 1.646034904119286230e-22 4.078197051069683329e-22 1.476867430645394142e-21 2.136996291646430596e-21 0.000000000000000000e+00 5.223481455227609575e-22 5.314681700084306435e-21 1.050310037543058390e-21 2.912091336474199136e-20 1.320000000000000000e+02 2.920920548184400147e-20 2.670466936972215149e-20 3.548566457410668560e-21 4.487485714287827073e-24 9.127992612144467895e-21 1.640871330832937249e-22 4.068951330090815150e-22 1.476430628167793302e-21 2.315283415368095898e-21 0.000000000000000000e+00 5.234707868374956400e-22 6.700128238419120111e-21 1.052456903391915938e-21 2.937785284619928652e-20 1.321500094589478351e+02 3.081525963476354076e-20 2.670867707268708211e-20 3.316126523057664502e-21 4.463912799310281496e-24 9.123034503489429900e-21 1.635707131934373547e-22 4.059704441647679708e-22 1.475994726321271590e-21 2.273135131549055400e-21 0.000000000000000000e+00 5.224132276091327661e-22 5.215027975899216420e-21 1.054604040327168101e-21 2.904649372571861460e-20 1.323000000000000114e+02 3.085579257556206273e-20 2.671268850099547805e-20 3.293391632681411161e-21 4.440234146343516631e-24 9.118047385793844853e-21 1.630543610943475315e-22 4.050458719342146724e-22 1.475571698305932913e-21 2.301987158904853444e-21 0.000000000000000000e+00 5.194130568773702528e-22 4.930427720385730382e-21 1.056750906484078519e-21 2.899854649375202526e-20 1.324500094375232493e+02 3.063558165286682040e-20 2.671670466406823040e-20 3.549118525866842380e-21 4.416525337681277148e-24 9.113000648078072672e-21 1.625379466330282221e-22 4.041211832219667430e-22 1.475173312663970827e-21 2.251516001135325436e-21 0.000000000000000000e+00 5.229163374336242381e-22 6.092522191166309754e-21 1.058898043112672983e-21 2.924677891781194617e-20 1.325999999999999943e+02 3.033201652202611545e-20 2.672072454875272708e-20 3.739369944888019136e-21 4.392885714287710343e-24 9.107954588072408055e-21 1.620215998654019138e-22 4.031966108593479708e-22 1.474775954436181164e-21 2.588072435876256778e-21 0.000000000000000000e+00 5.282419153378898222e-22 8.278240977558706365e-21 1.061044909576240913e-21 2.983170955761049680e-20 1.327500094161955246e+02 3.106255638406676384e-20 2.672474916430576997e-20 3.847967579448864353e-21 4.370170002692357713e-24 9.103000638842413417e-21 1.615051909351732485e-22 4.022719222785683640e-22 1.474396263157283992e-21 2.285053229766069176e-21 0.000000000000000000e+00 5.185804894849081684e-22 6.834438860003276155e-21 1.063192045899564572e-21 2.945463951448384738e-20 1.329000000000000057e+02 2.906632611009035758e-20 2.672877749773601050e-20 3.801397365409921169e-21 4.347457142859079271e-24 9.098080906583475834e-21 1.609888496035364942e-22 4.013473497844811282e-22 1.474036843600584551e-21 2.147285227574828306e-21 0.000000000000000000e+00 5.143819708137313767e-22 6.130911422546180506e-21 1.065292612838593141e-21 2.928500283660648032e-20 1.330500093949639790e+02 3.099447190277090954e-20 2.673281055813495763e-20 3.760395982413942090e-21 4.324779538664472484e-24 9.093160572430236795e-21 1.604724463096065103e-22 4.004226613345771598e-22 1.473675810347953298e-21 2.418359779827459188e-21 0.000000000000000000e+00 5.187327766899470356e-22 6.446685354660788902e-21 1.067383244014797438e-21 2.937079745357699819e-20 1.332000000000000171e+02 2.969964894448810200e-20 2.673684733267373002e-20 3.827687058977908204e-21 4.302209523811404384e-24 9.088240869729435306e-21 1.599561105211768786e-22 3.994980887096142855e-22 1.473282369664820393e-21 2.592525759389347183e-21 0.000000000000000000e+00 5.234611839760790118e-22 5.503303304095801024e-21 1.069473613322009280e-21 2.920423603244960213e-20 1.333500093738279588e+02 3.011088162995896205e-20 2.674088883027740015e-20 3.870008224650975032e-21 4.279636684702032040e-24 9.083320566576941158e-21 1.594397129714933618e-22 3.985734003899971269e-22 1.472889672875232752e-21 2.360707799503986129e-21 0.000000000000000000e+00 5.208338929528364773e-22 6.030214726127664611e-21 1.071564244203647859e-21 2.929621928713659124e-20 1.335000000000000000e+02 3.288364973169998076e-20 2.674493403828072456e-20 3.903814821254664277e-21 4.257266666668498119e-24 9.078400929475708951e-21 1.589233828362680422e-22 3.976488276347476310e-22 1.472512082197995419e-21 2.520003372248151344e-21 0.000000000000000000e+00 5.189590986798195151e-22 4.562343794598375080e-21 1.073654613805425044e-21 2.904974650779779948e-20 1.336500093527868103e+02 3.115085786281060474e-20 2.674898396544119574e-20 4.101964926465620835e-21 4.235122428876133293e-24 9.073480734182346911e-21 1.584069911416079580e-22 3.967241394448322620e-22 1.472156646264305569e-21 2.232745262969094932e-21 0.000000000000000000e+00 5.171438216336963741e-22 5.481565732894869588e-21 1.075745244393820289e-21 2.921419925098878714e-20 1.338000000000000114e+02 3.094447468354133682e-20 2.675303759925838768e-20 4.318242736348747104e-21 4.212980952382729539e-24 9.068561167306721068e-21 1.578906667724543914e-22 3.957995665598807883e-22 1.471802066669847859e-21 2.303373719343533241e-21 0.000000000000000000e+00 5.106343494683226777e-22 6.519075550949432210e-21 1.077835614288841184e-21 2.946498264338510221e-20 1.339500093318399365e+02 3.114095953816034890e-20 2.675709594832105133e-20 4.482691927554971450e-21 4.191027211647935025e-24 9.063641053506853255e-21 1.573742810465167726e-22 3.948748784990862798e-22 1.471448255610739419e-21 2.259302081576990059e-21 0.000000000000000000e+00 5.160258814518828802e-22 6.577382378408821557e-21 1.079926244585306826e-21 2.950137451494738258e-20 1.340999999999999943e+02 3.147237221202549491e-20 2.676115800029475779e-20 4.194907852638162531e-21 4.169171428573159359e-24 9.058721591995618204e-21 1.568579625592678199e-22 3.939503054850140868e-22 1.471095301762896550e-21 1.898781435132277900e-21 0.000000000000000000e+00 5.248072560451332350e-22 6.860046895306709443e-21 1.082016614772257136e-21 2.950038988348243728e-20 1.342500093109866555e+02 3.024596626327108691e-20 2.676522476359838798e-20 3.726470030571144060e-21 4.147312928972222303e-24 9.053811968535573369e-21 1.563415829187701571e-22 3.930256175527633650e-22 1.470743117923099326e-21 2.358472988605601942e-21 0.000000000000000000e+00 5.175012565474486561e-22 5.724417564858947912e-21 1.084107244778097504e-21 2.922929709051459209e-20 1.344000000000000057e+02 3.245172315899265377e-20 2.676929522606467167e-20 3.797427262734291919e-21 4.125828571430253088e-24 9.049048881806015452e-21 1.558252704323218761e-22 3.921010444101472441e-22 1.470391792164514179e-21 2.188150138787747413e-21 0.000000000000000000e+00 5.177808819715084447e-22 6.061726996309661883e-21 1.086170959784520956e-21 2.929541601980454449e-20 1.345500092902263702e+02 3.235729036015854992e-20 2.677337039594147023e-20 3.852057980999211913e-21 4.104398672826462723e-24 9.044285216000020354e-21 1.553088969971006227e-22 3.911763566058672321e-22 1.470041237882459960e-21 2.539600799108156026e-21 0.000000000000000000e+00 5.133794024605377110e-22 5.343347691288395248e-21 1.088213921099478213e-21 2.919311032959663201e-20 1.347000000000000171e+02 3.428768460878983827e-20 2.677744926122984570e-20 3.693296373283714246e-21 4.082980952382584807e-24 9.039482540727817481e-21 1.547925906335151479e-22 3.902517833352804015e-22 1.469679633592844904e-21 2.361465315109230295e-21 0.000000000000000000e+00 5.116600248794117144e-22 4.230730784607403829e-21 1.090256629369133559e-21 2.897665889374836443e-20 1.348500092695584556e+02 3.369661993479035337e-20 2.678153283000550841e-20 3.592225221467683883e-21 4.061693922702364894e-24 9.034600215471873872e-21 1.542762235266299628e-22 3.893270956584016897e-22 1.469294970869029925e-21 2.399220821239392415e-21 0.000000000000000000e+00 5.215357701062742970e-22 4.732040823198249783e-21 1.092299590402616530e-21 2.904696875106473301e-20 1.350000000000000000e+02 3.231364585023054563e-20 2.678562009043900826e-20 3.564649648826853748e-21 4.040409523811114007e-24 9.029718507594919121e-21 1.537599234112418872e-22 3.884025222604136999e-22 1.468911155534890813e-21 2.741103397451776085e-21 0.000000000000000000e+00 5.250589733327515064e-22 5.764814263920913568e-21 1.094342298953745786e-21 2.926199250463828337e-20 1.351500092489823146e+02 3.228682472899203630e-20 2.678971983593972656e-20 3.742521508571852238e-21 4.019362463930576580e-24 9.024915515930902855e-21 1.533078642304676672e-22 3.875724684452047992e-22 1.468551930278400644e-21 2.392797112177149162e-21 0.000000000000000000e+00 5.123467878969181271e-22 5.924794988827671636e-21 1.096385259707004446e-21 2.928768113721429874e-20 1.353500092353155253e+02 3.027678859216251464e-20 2.679519502613532158e-20 3.906387960580061424e-21 3.992181070439120695e-24 9.018564929811439335e-21 1.527278576720143336e-22 3.864992051658468599e-22 1.468090150399370529e-21 2.288795703219261435e-21 0.000000000000000000e+00 5.092787115618459462e-22 5.625950167344707793e-21 1.099109039243952930e-21 2.924486579528870714e-20 1.355000000000000000e+02 3.296567136839328552e-20 2.679930599695792545e-20 3.887928544302139960e-21 3.971796279071283222e-24 9.013770596434751123e-21 1.522928813198200105e-22 3.856943072109516875e-22 1.467744791802094731e-21 2.522788507693401580e-21 0.000000000000000000e+00 5.134853926378384694e-22 5.403424625296999740e-21 1.101151748261433332e-21 2.922209363436588384e-20 1.356500092148909573e+02 3.217032429795011188e-20 2.680342161258595891e-20 3.606822424673024456e-21 3.951252067823136160e-24 9.008888406537993877e-21 1.518578530312779069e-22 3.848893102464041702e-22 1.467400210069269970e-21 2.640861279128731083e-21 0.000000000000000000e+00 5.104321512332487983e-22 5.466833681613715538e-21 1.103194708550405201e-21 2.921053108706184186e-20 1.358000000000000114e+02 3.289488054591195555e-20 2.680754085928406260e-20 3.312743215426829216e-21 3.930653333334805127e-24 9.004006795850857886e-21 1.514228797722651011e-22 3.840844121819042119e-22 1.467056490494219785e-21 2.520271371791530012e-21 0.000000000000000000e+00 5.123417219988264504e-22 5.196669636433898246e-21 1.105237417846045935e-21 2.911794223020266208e-20 1.359500091945565146e+02 3.208407643191451376e-20 2.681166474687233379e-20 3.071751444630335997e-21 3.910052070615693186e-24 8.999195938079409970e-21 1.509878547227041823e-22 3.832794153264778351e-22 1.466692592842507205e-21 2.399412100714401412e-21 0.000000000000000000e+00 5.171258097049120183e-22 5.140200061241303740e-21 1.107253780725370919e-21 2.907369462242005489e-20 1.360999999999999943e+02 3.253665913321547504e-20 2.681579226181864986e-20 3.137748904911819194e-21 3.890186976745619645e-24 8.994433509808231484e-21 1.505528846118643767e-22 3.824745171528569243e-22 1.466315580017181045e-21 2.512958317460457661e-21 0.000000000000000000e+00 5.169564138151880447e-22 5.167669822511847511e-21 1.109244693661577962e-21 2.909756871366980836e-20 1.362500091743116286e+02 2.988473962605635424e-20 2.681992441373644979e-20 3.371503254630810029e-21 3.870371811394666807e-24 8.989670531047025464e-21 1.501178628563923822e-22 3.816695204060709109e-22 1.465939326495335139e-21 2.216636351595541323e-21 0.000000000000000000e+00 5.091302009707891564e-22 5.416927204240546299e-21 1.111235850418178706e-21 2.914716781822289962e-20 1.364000000000000057e+02 3.160920458578091382e-20 2.682406018929780469e-20 3.612567684838249500e-21 3.850577674419995255e-24 8.984939848812635108e-21 1.496828959499890388e-22 3.808646221238094957e-22 1.465594213184986251e-21 2.671475342297207711e-21 0.000000000000000000e+00 5.164331155214603160e-22 5.959103413386827700e-21 1.113226763623107707e-21 2.932199020264108150e-20 1.365500091541556742e+02 3.129535037422078877e-20 2.682820059790852924e-20 3.732515180723454887e-21 3.831041598529935832e-24 8.980213454813585925e-21 1.492478775450079508e-22 3.800596254851867830e-22 1.465254537620764755e-21 2.444543783202963448e-21 0.000000000000000000e+00 5.119440860481543731e-22 5.271013156838804096e-21 1.115217920112166877e-21 2.918744812653004399e-20 1.367000000000000171e+02 2.899333949414903470e-20 2.683234462644588131e-20 3.636886072065562683e-21 3.811507906978095552e-24 8.975487650768993378e-21 1.488129139006139852e-22 3.792547270947620200e-22 1.464940655338136011e-21 2.192387339753055967e-21 0.000000000000000000e+00 5.213739070247530934e-22 5.002892833828437389e-21 1.117208833584637452e-21 2.911062636544119378e-20 1.368500091340881113e+02 3.110982248584765214e-20 2.683649328410711245e-20 3.494911154354138291e-21 3.792027664648628513e-24 8.970761312268629321e-21 1.483778989038577150e-22 3.784497305638282727e-22 1.464630136045847468e-21 2.508978611884193248e-21 0.000000000000000000e+00 5.216038592847078514e-22 5.795271769682541331e-21 1.119199989807328285e-21 2.926775628679729208e-20 1.370000000000000000e+02 3.170367903948574834e-20 2.684064555797562424e-20 3.380318803421462407e-21 3.772773023257130694e-24 8.966035676572401923e-21 1.479429385803941938e-22 3.776448320657147324e-22 1.464320349832113801e-21 2.356343599945228739e-21 0.000000000000000000e+00 5.203228190151898925e-22 4.994895509401754837e-21 1.121190903546166821e-21 2.909595327837271772e-20 1.371500091141083431e+02 3.067846079510110616e-20 2.684480245703916614e-20 3.565025925099059145e-21 3.753516039306460730e-24 8.961309478482952015e-21 1.475079270509679138e-22 3.768398356419986712e-22 1.464011221718522866e-21 2.486259461256121065e-21 0.000000000000000000e+00 5.200297382011572470e-22 5.018824124754110585e-21 1.123182059503655032e-21 2.913532317893533861e-20 1.373500091008369850e+02 2.894406354833547806e-20 2.685035105739960680e-20 3.670792869406248407e-21 3.728036989021046843e-24 8.955008283850940001e-21 1.469279496465133894e-22 3.757665723605187294e-22 1.463600159033215557e-21 2.354797200000753671e-21 0.000000000000000000e+00 5.260033455190617054e-22 5.057705850789203697e-21 1.125836772635183136e-21 2.914760400971148592e-20 1.375000000000000000e+02 3.047375325472990460e-20 2.685451705648262344e-20 3.605264444722872175e-21 3.709075348838467572e-24 8.950282688970298922e-21 1.464929949926578278e-22 3.749616736839690964e-22 1.463292693480148105e-21 2.196754409821737237e-21 0.000000000000000000e+00 5.311170641268668593e-22 4.816858403285293718e-21 1.127809953298213574e-21 2.908875675282571001e-20 1.376500090810022527e+02 3.133740777991018104e-20 2.685868767420520790e-20 3.629240224303882301e-21 3.690111410133142097e-24 8.945556533858484289e-21 1.460579893773139325e-22 3.741566774379108096e-22 1.462950875574246679e-21 2.317759752730294084e-21 0.000000000000000000e+00 5.410721621058795460e-22 5.465830798119225324e-21 1.129750040449614899e-21 2.921816978777094953e-20 1.378000000000000114e+02 3.059156106876569218e-20 2.686286189820521897e-20 3.602055971684634954e-21 3.671361860466338122e-24 8.940831001205569576e-21 1.456230382084099384e-22 3.733517786549216677e-22 1.462609782088023858e-21 2.416268611946789018e-21 0.000000000000000000e+00 5.407899320790687781e-22 5.003685634365345068e-21 1.131689892709426151e-21 2.914232066509606874e-20 1.379500090612537804e+02 3.038718394271802934e-20 2.686704073690715886e-20 3.470582765737275567e-21 3.652663056551898570e-24 8.936134886539638285e-21 1.451880362250280610e-22 3.725467825148399801e-22 1.462278672969861547e-21 2.378600498925288745e-21 0.000000000000000000e+00 5.575384097490515556e-22 4.644971761937383011e-21 1.133629979605417756e-21 2.906656053517471340e-20 1.380999999999999943e+02 2.963441354131968491e-20 2.687122317815854789e-20 3.552980216722130075e-21 3.633966511629098684e-24 8.931521734324795666e-21 1.447530886052923265e-22 3.717418836258743331e-22 1.461973978701725033e-21 2.529007598079898094e-21 0.000000000000000000e+00 5.530670381350165048e-22 4.344612613155505048e-21 1.135569832120638351e-21 2.904516914717809694e-20 1.382500090415910279e+02 3.229659138051460975e-20 2.687541023017097072e-20 3.767059097458834758e-21 3.615918915010251194e-24 8.926908291198239461e-21 1.443180903183648125e-22 3.709368875913091562e-22 1.461669946703769061e-21 2.295752921040109520e-21 0.000000000000000000e+00 5.517695590019674841e-22 5.199765846306515123e-21 1.137509918762329151e-21 2.919536675072483500e-20 1.384000000000000057e+02 3.046300628102579711e-20 2.687960088100256917e-20 4.010338061732311769e-21 3.597920000001157373e-24 8.922260072861238863e-21 1.438831463135609569e-22 3.701319885968269045e-22 1.461366650752657462e-21 2.237110757714741598e-21 0.000000000000000000e+00 5.580888130879169507e-22 5.336061813708682372e-21 1.139449771531850740e-21 2.925036434487652868e-20 1.385500090220134268e+02 3.013238410427426292e-20 2.688379613865109551e-20 4.087234775916195286e-21 3.579918907288445803e-24 8.917570893342980681e-21 1.434481517891542094e-22 3.693269926673213471e-22 1.461064018191662192e-21 2.424528546592328248e-21 0.000000000000000000e+00 5.561832851839227071e-22 5.281360421034653558e-21 1.141389857920341749e-21 2.926844668719609657e-20 1.387500090090087213e+02 3.073999246805912478e-20 2.688939585628614328e-20 3.838695162456777203e-21 3.555695653049551821e-24 8.911326251566680686e-21 1.428681969348195206e-22 3.682537293844104525e-22 1.460659337914616973e-21 2.368305306381630996e-21 0.000000000000000000e+00 5.624148769049383518e-22 5.074914595451657622e-21 1.143976484026291855e-21 2.919700510272640116e-20 1.389000000000000057e+02 3.013304503688076977e-20 2.689360017268951843e-20 3.774835897672075727e-21 3.537529302326684333e-24 8.906748962833893190e-21 1.424332591053962438e-22 3.674488302150812684e-22 1.460324142315977291e-21 2.102555657046654506e-21 0.000000000000000000e+00 5.529907248693571019e-22 4.658528772136997327e-21 1.145916337217204659e-21 2.910111186855499487e-20 1.390500089895718077e+02 3.091600613806755707e-20 2.689780908932927394e-20 3.883167901711312420e-21 3.519680770489173245e-24 8.902171261366020563e-21 1.419982710030990983e-22 3.666438344596676939e-22 1.459989593846644227e-21 2.280489762629786011e-21 0.000000000000000000e+00 5.543581426869598052e-22 4.966185953152064645e-21 1.147853910818063793e-21 2.918209161742647851e-20 1.392000000000000171e+02 3.114468481635407215e-20 2.690202159482976601e-20 4.153228655887294116e-21 3.502200000001070620e-24 8.897594261947586376e-21 1.415633369719058024e-22 3.658389351860338398e-22 1.459664906425598451e-21 2.721396065914330244e-21 0.000000000000000000e+00 5.548103971474021940e-22 4.326746215229416845e-21 1.149751544863963321e-21 2.915778185264814123e-20 1.393500089702185960e+02 3.068893600510647611e-20 2.690623869661410356e-20 4.197101954878575256e-21 3.484717136381036286e-24 8.893016725693876177e-21 1.411283528163717059e-22 3.650339395344758024e-22 1.459365994545155864e-21 2.504599799695136471e-21 0.000000000000000000e+00 5.592528122014462731e-22 4.388845416176208032e-21 1.151649406130878135e-21 2.915654411357560200e-20 1.395500089573626781e+02 3.014754205211627349e-20 2.691186752400778620e-20 4.040513228760210570e-21 3.461632607896579587e-24 8.886913746271714913e-21 1.405484117323485451e-22 3.639606762507664651e-22 1.458968562352559327e-21 2.502470384832407381e-21 0.000000000000000000e+00 5.546888706274615823e-22 4.902584796186662752e-21 1.154179736340005768e-21 2.921934163378215861e-20 1.397000000000000171e+02 3.122791661751749411e-20 2.691609366090974246e-20 3.910079335676286042e-21 3.444410909091934138e-24 8.882336805616164331e-21 1.401134841920913150e-22 3.631557768042881567e-22 1.458671326298642599e-21 2.599576478427041524e-21 0.000000000000000000e+00 5.534669098426936248e-22 5.302600740454704696e-21 1.156077370793403859e-21 2.928238696381796689e-20 1.398500089381477380e+02 3.047177076071202025e-20 2.692032438750113000e-20 3.971247774649673690e-21 3.427187155557323317e-24 8.877759330054833660e-21 1.396785067759703616e-22 3.623507813248325545e-22 1.458374758483910808e-21 2.536201491758764976e-21 0.000000000000000000e+00 5.498887312824015240e-22 4.867014953034323288e-21 1.157975231654569245e-21 2.921181949841324791e-20 1.400000000000000000e+02 3.238860542918545851e-20 2.692455869297914878e-20 4.094056069971803751e-21 3.410194545455544338e-24 8.873182411170414961e-21 1.392435832295416813e-22 3.615458817752408691e-22 1.458078930058700128e-21 2.465095866493802010e-21 0.000000000000000000e+00 5.496566419745034237e-22 5.304647517676031164e-21 1.159872866351068032e-21 2.930129762350839022e-20 1.401500089190150504e+02 3.025156050054298622e-20 2.692879758418586673e-20 4.015306975457632323e-21 3.393216263257918509e-24 8.868604958587653879e-21 1.388086099569397846e-22 3.607408863984572224e-22 1.457749475229559131e-21 2.465341936426784693e-21 0.000000000000000000e+00 5.371048971762223649e-22 4.875971713038633682e-21 1.161770726970173552e-21 2.921815589860074656e-20 1.403000000000000114e+02 3.106729178247086614e-20 2.693304005053499747e-20 3.912160110728384435e-21 3.376240000000971170e-24 8.864028061546165131e-21 1.383736904810721873e-22 3.599359867461934405e-22 1.457420750694325821e-21 2.265724823373985681e-21 0.000000000000000000e+00 5.396802241400961095e-22 5.164959039951006047e-21 1.163668361908732393e-21 2.924026528724316527e-20 1.404500088999641321e+02 3.852515924922691009e-20 2.693728709864906493e-20 3.839641260978562694e-21 3.359507189068595789e-24 8.859450786830781767e-21 1.379387214292150003e-22 3.591309914716431016e-22 1.457099542286527332e-21 2.674268025884721588e-21 0.000000000000000000e+00 5.448282264384250176e-22 4.358394636922664173e-21 1.165566222286812295e-21 2.913630034364250309e-20 1.406500088873086440e+02 3.200855544404270899e-20 2.694295583277436036e-20 3.877827356858497970e-21 3.337198099571150448e-24 8.853348132825452959e-21 1.373588004281396979e-22 3.580577281868581870e-22 1.456724744496895452e-21 2.663997885397344324e-21 0.000000000000000000e+00 5.471920051406213496e-22 5.217344933875945900e-21 1.168096552498475609e-21 2.928468472787807191e-20 1.408000000000000114e+02 2.945529855413173466e-20 2.694721188343926932e-20 4.051005951762991666e-21 3.320560000000927394e-24 8.848771407981330446e-21 1.369238879123448820e-22 3.572528283644478044e-22 1.456459612919503686e-21 2.778470352271949793e-21 0.000000000000000000e+00 5.401300957661951473e-22 4.851410457978333450e-21 1.169948195422248529e-21 2.925829620019076629e-20 1.409500088683927572e+02 3.049908400730248000e-20 2.695147250925621487e-20 4.386400601183278226e-21 3.304059024477712603e-24 8.844220314894057803e-21 1.364889260720545071e-22 3.564478332593194445e-22 1.456195032054004705e-21 2.652258587172497173e-21 0.000000000000000000e+00 5.421610987276985337e-22 4.679450673978125092e-21 1.171799209478075430e-21 2.926956779780547704e-20 1.410999999999999943e+02 2.981444118429345891e-20 2.695573670022070999e-20 4.580259951520300520e-21 3.287560000000903794e-24 8.839679292235103288e-21 1.360540178410770009e-22 3.556429333354005169e-22 1.455931064818311585e-21 2.080948887897587642e-21 0.000000000000000000e+00 5.298013445415932127e-22 3.693344666065381919e-21 1.173650004673246806e-21 2.911399110092251575e-20 1.412500088495572470e+02 3.060589418663771962e-20 2.696000546236557091e-20 4.564626290300520921e-21 3.271179950926101434e-24 8.835137795071030012e-21 1.356190604372706368e-22 3.548379383313493897e-22 1.455667649132901468e-21 2.664690682002114308e-21 0.000000000000000000e+00 5.394974106560223094e-22 3.655415888268494561e-21 1.175501018496655716e-21 2.915709434946675633e-20 1.414500088370446349e+02 3.092396887404517084e-20 2.696570483368589168e-20 3.694379755099542340e-21 3.249525406826314032e-24 8.829082917254148469e-21 1.350541803390539805e-22 3.537875914640479464e-22 1.455273844731048724e-21 2.490420995002431867e-21 0.000000000000000000e+00 5.337132664353030050e-22 4.266959087709113502e-21 1.177968891176256989e-21 2.910486590029344121e-20 1.415999999999999943e+02 3.109267155310745962e-20 2.696999028500836723e-20 3.377947896273410626e-21 3.233285454546316945e-24 8.824542038336191439e-21 1.346875889094040295e-22 3.530868766353891708e-22 1.454977459593210792e-21 2.369970404600052537e-21 0.000000000000000000e+00 5.301073211060413111e-22 3.077567231857062362e-21 1.179819686758244247e-21 2.890820643262561583e-20 1.417500088183418825e+02 3.417906114488536362e-20 2.697428026441968164e-20 3.252590584734193416e-21 3.217541301196252946e-24 8.820049993945933075e-21 1.343209554134719332e-22 3.523860793259301411e-22 1.454697648500343596e-21 2.572001606526388736e-21 0.000000000000000000e+00 5.468254899024006361e-22 4.118039980547783342e-21 1.181670700196475444e-21 2.904327127177021229e-20 1.419000000000000057e+02 3.618128137245447193e-20 2.697857376071246320e-20 2.896212195617711224e-21 3.201875555556393115e-24 8.815614751401768402e-21 1.339543661167950381e-22 3.516853644098975287e-22 1.454436775107411870e-21 2.703441271541666586e-21 0.000000000000000000e+00 5.422680856585508472e-22 4.058269297359500777e-21 1.183521496009242712e-21 2.901166137691392701e-20 1.420500087997181424e+02 3.287175356022043973e-20 2.698287178113275868e-20 2.766541008552856314e-21 3.186207969808042530e-24 8.811178997846779285e-21 1.335877348632358478e-22 3.509845671874432306e-22 1.454176455518203119e-21 2.612019453231258096e-21 0.000000000000000000e+00 5.400917851191742956e-22 4.403941190335924768e-21 1.185372509217668713e-21 2.904368812599604343e-20 1.422500087873459620e+02 3.013041233366057198e-20 2.698860838801146141e-20 3.165591188683174122e-21 3.165607096271098470e-24 8.805265022594306493e-21 1.330989236295366589e-22 3.500502257615814125e-22 1.453830292765305117e-21 2.700977662009588702e-21 0.000000000000000000e+00 5.431409267849933001e-22 4.391191769748499676e-21 1.187840381899002759e-21 2.909426640709973347e-20 1.424000000000000057e+02 3.168519280657572761e-20 2.699291527552131968e-20 3.248741513411502982e-21 3.150181333334134535e-24 8.800829812373573268e-21 1.327323379686876769e-22 3.493495107007449172e-22 1.453571368463499755e-21 2.348565174052159063e-21 0.000000000000000000e+00 5.455050178026306749e-22 4.125298457084767283e-21 1.189655119615955962e-21 2.903662592734735429e-20 1.425500087688527628e+02 3.288673378129739484e-20 2.699722668055054036e-20 3.141766676501789271e-21 3.134730000319686916e-24 8.796389442177627550e-21 1.323657105333286825e-22 3.486487136224846555e-22 1.453312999345532561e-21 2.639525984237712852e-21 0.000000000000000000e+00 5.457950913564442866e-22 3.916404900901185600e-21 1.191459882849232329e-21 2.902363540840382607e-20 1.427000000000000171e+02 3.072213037736885177e-20 2.700154159254314939e-20 2.775995191462654464e-21 3.119185454546233055e-24 8.791884515702913924e-21 1.319991271038110000e-22 3.479479984752532752e-22 1.453055246168111004e-21 2.498952471357899771e-21 0.000000000000000000e+00 5.454030854637735313e-22 4.026728638159497067e-21 1.193264435085469709e-21 2.899167386316982814e-20 1.428500087504372402e+02 2.993176870892742794e-20 2.700586101808672110e-20 3.058649897443269426e-21 3.103639093137273773e-24 8.787379072924174069e-21 1.316325020092526036e-22 3.472472014830250000e-22 1.452798048999080102e-21 2.466988179633870726e-21 0.000000000000000000e+00 5.501854983264699780e-22 4.586434660104377079e-21 1.195069198097187960e-21 2.910310545411872594e-20 1.430500087382031609e+02 3.040273715146596881e-20 2.701162614940104830e-20 3.720357746494717147e-21 3.083247126957168355e-24 8.781435022346514951e-21 1.311436989044806261e-22 3.463128600565179765e-22 1.452435881194798167e-21 2.594620236003385478e-21 0.000000000000000000e+00 5.471274182484291417e-22 3.993010142004108151e-21 1.197475408263008179e-21 2.910736677783170960e-20 1.432000000000000171e+02 3.167293819374760315e-20 2.701595441843801714e-20 3.943861033281823014e-21 3.068261333334076580e-24 8.777034845264937437e-21 1.307771192795854744e-22 3.456121447661006637e-22 1.452146460937734533e-21 2.569897842676382912e-21 0.000000000000000000e+00 5.512168434416251331e-22 3.623455522658714576e-21 1.199279960867992306e-21 2.908905945731563945e-20 1.433500087199160191e+02 3.137390594871950107e-20 2.702028719440618439e-20 3.981865790535083740e-21 3.053273795450902743e-24 8.772634165703852932e-21 1.304104981722198681e-22 3.449113479164585837e-22 1.451857582389366497e-21 2.695286086026594459e-21 0.000000000000000000e+00 5.508491984967006887e-22 3.861214319461795260e-21 1.201084723512508316e-21 2.913886988893291742e-20 1.435500087077670628e+02 3.011660106248987766e-20 2.702607011644459428e-20 3.937330126153154100e-21 3.033490697937974731e-24 8.766729819869757265e-21 1.299217003351011992e-22 3.439770064895539141e-22 1.451509206998453553e-21 2.545423176673375319e-21 0.000000000000000000e+00 5.535821304182103266e-22 3.662683977988260929e-21 1.203490933679352625e-21 2.909738735485866953e-20 1.437000000000000171e+02 3.037100799935672266e-20 2.703041172114129058e-20 3.901360051713783360e-21 3.018718222222933318e-24 8.762294879086368976e-21 1.295551246254914032e-22 3.432762910569480053e-22 1.451255349692489843e-21 2.642898327345062163e-21 0.000000000000000000e+00 5.577804215189541607e-22 3.692018488540432889e-21 1.205295486650515092e-21 2.910776738703521163e-20 1.438500086896069945e+02 3.164107192937489434e-20 2.703475782614229808e-20 3.947707162610505346e-21 3.003944033059854908e-24 8.757866411166124771e-21 1.291885076161923898e-22 3.425754943489008496e-22 1.451002051155475934e-21 2.548181020451043291e-21 0.000000000000000000e+00 5.630658732193444426e-22 3.615301230526674003e-21 1.207100248930381469e-21 2.909879677822903852e-20 1.440000000000000000e+02 3.559433159333743655e-20 2.703910742196184289e-20 4.045163148666246859e-21 2.989678260870258176e-24 8.753466514604355132e-21 1.288219343106119515e-22 3.418747788314565513e-22 1.450749370417886468e-21 2.629960682868460136e-21 0.000000000000000000e+00 5.544388888527584695e-22 4.335900871672520396e-21 1.208898773270297895e-21 2.922025967569444275e-20 1.441500086715224711e+02 3.218515152406785391e-20 2.704346151410621908e-20 3.943760331166334574e-21 2.975447003424072990e-24 8.749066128123712233e-21 1.284553198151416026e-22 3.411739822078949018e-22 1.450497249262377246e-21 2.298702553648605918e-21 0.000000000000000000e+00 5.528930597169095595e-22 4.038416639105816214e-21 1.210690183702140059e-21 2.913845173898549941e-20 1.443500086595078926e+02 3.129287251246612486e-20 2.704927284194773553e-20 3.792452778369871466e-21 2.956452505869915683e-24 8.743288596462550429e-21 1.279665307216635370e-22 3.402396407803624241e-22 1.450140088458397445e-21 2.577540051600957216e-21 0.000000000000000000e+00 5.538698630889843152e-22 3.368151761168143107e-21 1.213078592726825700e-21 2.906015311039284013e-20 1.445000000000000000e+02 2.872112081218409817e-20 2.705363573917002846e-20 3.730642039397748952e-21 2.942120000000662032e-24 8.739022583465058950e-21 1.275999615172536549e-22 3.395389251223038928e-22 1.449856463953480304e-21 2.776521218681131467e-21 0.000000000000000000e+00 5.555409752026324276e-22 3.770751336036515258e-21 1.214869796190708738e-21 2.912272726608816654e-20 1.446500086415483111e+02 3.105819016059264202e-20 2.705800312607919145e-20 3.929435371475146222e-21 2.927785840919370933e-24 8.734756087801773465e-21 1.272333513062216599e-22 3.388381286387727728e-22 1.449573385289162030e-21 2.662359699615525034e-21 0.000000000000000000e+00 5.531935946742169441e-22 3.740163574252332267e-21 1.216661206264598014e-21 2.913704688148051036e-20 1.448500086296165819e+02 2.973752974259873370e-20 2.706383217040959218e-20 4.094126889401893630e-21 2.908781409121213303e-24 8.728924915143547124e-21 1.267445678837953666e-22 3.379037872108532753e-22 1.449255063883281323e-21 2.437781998366587754e-21 0.000000000000000000e+00 5.553278111397124437e-22 3.493890879611222445e-21 1.219049615290273139e-21 2.911326388877568672e-20 1.450000000000000000e+02 3.101150653550475686e-20 2.706820834759871396e-20 4.122604937984265029e-21 2.894648888889522635e-24 8.724525071877394357e-21 1.263780029025716490e-22 3.372030714131512814e-22 1.449026266279946416e-21 2.240338651265333252e-21 0.000000000000000000e+00 5.552835832125307078e-22 3.390657206980865114e-21 1.220840819111119581e-21 2.909200819632205609e-20 1.451500086117806632e+02 2.988832843400850627e-20 2.707258900782996462e-20 4.166598116483783508e-21 2.880514744135068705e-24 8.720151533386454629e-21 1.260113970983960114e-22 3.365022750686858920e-22 1.448797941859134933e-21 2.496472087136878600e-21 0.000000000000000000e+00 5.546622991813182187e-22 3.651100969241451235e-21 1.222632228829522250e-21 2.915339063721345783e-20 1.453500085999309590e+02 3.132673713862556647e-20 2.707843574005080594e-20 4.119423559368384399e-21 2.862106175050366001e-24 8.714463506277361597e-21 1.255226195131327365e-22 3.355679336403831834e-22 1.448494304148740735e-21 2.530318042829482541e-21 0.000000000000000000e+00 5.491226310184560781e-22 3.499124246678357717e-21 1.225020637856176891e-21 2.913465811739192597e-20 1.455000000000000000e+02 2.975538245821833447e-20 2.708282517575180670e-20 4.005470029615418983e-21 2.848476521739736313e-24 8.710197786968473757e-21 1.251560588818656664e-22 3.348672177039986699e-22 1.448267172168969108e-21 2.677347986919205360e-21 0.000000000000000000e+00 5.564457244316408025e-22 3.380726412740984045e-21 1.226811842031530424e-21 2.912092449795875096e-20 1.456500085822173958e+02 3.268874041254007202e-20 2.708721908784358080e-20 3.956058796039840146e-21 2.834845307094756767e-24 8.705851197849809963e-21 1.247894576117991041e-22 3.341664214976441807e-22 1.448020285345790805e-21 2.602220741209707320e-21 0.000000000000000000e+00 5.506724751898110666e-22 3.696423966317059968e-21 1.228596458798542411e-21 2.914843884219225738e-20 1.458000000000000114e+02 3.036658460548862104e-20 2.709161646834559801e-20 3.924713474042015717e-21 2.821382608696240406e-24 8.701451548325261207e-21 1.244228996534214705e-22 3.334657054785070278e-22 1.447760435604610745e-21 2.651819125676701216e-21 0.000000000000000000e+00 5.364145548476529051e-22 3.663805507239950135e-21 1.230367042857083467e-21 2.914711264512990387e-20 1.459500085645766490e+02 3.288343714919234170e-20 2.709601832124442814e-20 3.886613868869939865e-21 2.807960103222374406e-24 8.697051408091240436e-21 1.240563011670022202e-22 3.327649093545650370e-22 1.447501046444156446e-21 2.666891766811906727e-21 0.000000000000000000e+00 5.386945738614269506e-22 4.302958276434635089e-21 1.232137829326139953e-21 2.923347714760822786e-20 1.461500085528564057e+02 3.119346784681835410e-20 2.710189329454304622e-20 3.912551303072338150e-21 2.790076636422373734e-24 8.691327817105167755e-21 1.235675332831785758e-22 3.318305679256575130e-22 1.447191956920955883e-21 2.518373724074901078e-21 0.000000000000000000e+00 5.469890233578201031e-22 4.135163662825473672e-21 1.234498743011680131e-21 2.920350285066479289e-20 1.463000000000000114e+02 3.130963473264790720e-20 2.710630389919053113e-20 3.899324041474871033e-21 2.776838260870126425e-24 8.687062239027202372e-21 1.232009798880727392e-22 3.311298517693544164e-22 1.446967480373590843e-21 2.759651241652472070e-21 0.000000000000000000e+00 5.561301121459222634e-22 3.521830977057245897e-21 1.236269327416815038e-21 2.914612578746541916e-20 1.464500085353360532e+02 3.051333487633505275e-20 2.711071896957311853e-20 3.830612262417327159e-21 2.763598377099155814e-24 8.682800730035328428e-21 1.228343861500262202e-22 3.304290557820159188e-22 1.446743479797874953e-21 2.432206087719480611e-21 0.000000000000000000e+00 5.538455949047240398e-22 3.895295882217581817e-21 1.238040113540698798e-21 2.915821483869833057e-20 1.466500085236956465e+02 3.053745328170633075e-20 2.711661155629062806e-20 3.882742589224517282e-21 2.746015781289941118e-24 8.677158435284749335e-21 1.223456245667240497e-22 3.294947143527354340e-22 1.446445609934381033e-21 2.531099070891294810e-21 0.000000000000000000e+00 5.614150358431262216e-22 3.850621653002294722e-21 1.240401027227181252e-21 2.917160725180835394e-20 1.468000000000000114e+02 3.158198680102005319e-20 2.712103536358113256e-20 3.809458004562613011e-21 2.732986086957059266e-24 8.672926949547297168e-21 1.219790758751600113e-22 3.287939980602018050e-22 1.446222805877812191e-21 2.549586794022831919e-21 0.000000000000000000e+00 5.590440605239016526e-22 3.641219306894489661e-21 1.242171611976546420e-21 2.913951157880410338e-20 1.469500085062944095e+02 3.045133171477791693e-20 2.712546362993871870e-20 3.499383244755863381e-21 2.719954913236347814e-24 8.668676809925677178e-21 1.216124870264661057e-22 3.280932022085373607e-22 1.445982882368848870e-21 2.649356267874544511e-21 0.000000000000000000e+00 5.605636696188868847e-22 3.715245779623611987e-21 1.243942397757606186e-21 2.912180438541054463e-20 1.471500084947330151e+02 2.919296091523100791e-20 2.713137380138922672e-20 3.453797441387010937e-21 2.702690576755998922e-24 8.662989140859330394e-21 1.211237319349470152e-22 3.271588607788877707e-22 1.445643245873760859e-21 2.633786434946476373e-21 0.000000000000000000e+00 5.616931344673525275e-22 3.578708987965919655e-21 1.246303311445021513e-21 2.910175076650666983e-20 1.473000000000000114e+02 3.078700455561901963e-20 2.713581078980271055e-20 3.757675993988712574e-21 2.689843478261384342e-24 8.658723692708372678e-21 1.207571880928650553e-22 3.264581443510491465e-22 1.445389107760338283e-21 2.893681304382142593e-21 0.000000000000000000e+00 5.495262816708902704e-22 4.243860158697913069e-21 1.248070787529078056e-21 2.925576125435579065e-20 1.474500084774497566e+02 3.164656148587296009e-20 2.714025223060909218e-20 4.348271962315423786e-21 2.676994926062421292e-24 8.654457769830057427e-21 1.203906042802701268e-22 3.257573486341385315e-22 1.445166241960671185e-21 2.744253427164957450e-21 0.000000000000000000e+00 5.547795586869108512e-22 4.264911451549258339e-21 1.249801805492185127e-21 2.932916134743569234e-20 1.476500084659665788e+02 3.164967716739876369e-20 2.714617995808366379e-20 4.469289174444564709e-21 2.660022763439321444e-24 8.648770206776300242e-21 1.199018558796129009e-22 3.248230072041235039e-22 1.444872820681495757e-21 2.635830474207855006e-21 0.000000000000000000e+00 5.589738046261662682e-22 3.374380940535334451e-21 1.252109698876809296e-21 2.922520639018140422e-20 1.478000000000000114e+02 3.199133291694473452e-20 2.715063010608293987e-20 4.387640307868491348e-21 2.647358260870056593e-24 8.644547456471244038e-21 1.195353170389151250e-22 3.241222906418965351e-22 1.444653354620618076e-21 2.381738173281006170e-21 0.000000000000000000e+00 5.501257126186166212e-22 3.889959079482335439e-21 1.253840521321913005e-21 2.925785177263173105e-20 1.479500084488000482e+02 3.114409926211646343e-20 2.715508469979486927e-20 4.384749837583994952e-21 2.634692330106151075e-24 8.640409584800253450e-21 1.191687384152281965e-22 3.234214950588289294e-22 1.444434367697747960e-21 2.472852818747437734e-21 0.000000000000000000e+00 5.541415817452095392e-22 4.677447056902140073e-21 1.255571538954417650e-21 2.938304917866025708e-20 1.481500084373942911e+02 3.127686132936559396e-20 2.716103178830691647e-20 4.193566674813737242e-21 2.618313355354831322e-24 8.634892902377479268e-21 1.186974988393844770e-22 3.225146091537473893e-22 1.444143185791519604e-21 2.729947777107808098e-21 0.000000000000000000e+00 5.548080669576421815e-22 4.388181823863767956e-21 1.257879432339935195e-21 2.933720356655567073e-20 1.483000000000000114e+02 3.182072056203418387e-20 2.716550111375563602e-20 3.941557840927142591e-21 2.606097021277065349e-24 8.630693032914108948e-21 1.183887826012589805e-22 3.219045923527001671e-22 1.443903376727907067e-21 2.560248505549732880e-21 0.000000000000000000e+00 5.517284517459404740e-22 3.949801151743655069e-21 1.259610255114747765e-21 2.922735905370955865e-20 1.484500084203432948e+02 3.084073296945647549e-20 2.716997485066991195e-20 3.602952265346032362e-21 2.593879324939750581e-24 8.626461390846916016e-21 1.180800324416501687e-22 3.212945069911088440e-22 1.443653026091808144e-21 2.571302552873158387e-21 0.000000000000000000e+00 5.553855186775157717e-22 4.274755070143490991e-21 1.261341272418876653e-21 2.923338008151643839e-20 1.486500084090142479e+02 3.010756916377290344e-20 2.717594557542711471e-20 3.581849184031016982e-21 2.577845283294802737e-24 8.620825895787884694e-21 1.176683899102401263e-22 3.204811055491941627e-22 1.443322218977058545e-21 2.717391342578558844e-21 0.000000000000000000e+00 5.488269850533203583e-22 4.054062385875530769e-21 1.263649165805279298e-21 2.921639433767177943e-20 1.488500083977156123e+02 3.247389708068545662e-20 2.718192324139006792e-20 3.746664620055169293e-21 2.561811241647417579e-24 8.615309385772096166e-21 1.172567487828704645e-22 3.196677041071557254e-22 1.443034158532293276e-21 2.580278704014804690e-21 0.000000000000000000e+00 5.469810405551948024e-22 4.223097351993371051e-21 1.265957059192033087e-21 2.925253011945411576e-20 1.490000000000000000e+02 3.039428153962115579e-20 2.718641079216971701e-20 3.851825536722536450e-21 2.549737391304789989e-24 8.611172181369252812e-21 1.169480361344158965e-22 3.190576871447350870e-22 1.442830180726661711e-21 2.809777980565227385e-21 0.000000000000000000e+00 5.595639308867060754e-22 4.454357300109606292e-21 1.267686956959999278e-21 2.932479004897223431e-20 1.491500083808244312e+02 2.824568022025662291e-20 2.719090274507972941e-20 3.845496108129888632e-21 2.537619322975576289e-24 8.607034467765280574e-21 1.166392897569115166e-22 3.184476019438672728e-22 1.442634896517281989e-21 2.625541761926578740e-21 0.000000000000000000e+00 5.573253302558995922e-22 4.500929392433650991e-21 1.269387073234048488e-21 2.931695891847104048e-20 1.493500083696013689e+02 3.282975908229888958e-20 2.719689774402384842e-20 3.708128167858247179e-21 2.521462802143066888e-24 8.601517836941901091e-21 1.162276522050278814e-22 3.176342005015215142e-22 1.442375181354206338e-21 2.523007307949561367e-21 0.000000000000000000e+00 5.614617849848495013e-22 4.734384535766679688e-21 1.271653768160429485e-21 2.933112218841887439e-20 1.495000000000000000e+02 3.169782487422283498e-20 2.720139828714026951e-20 3.631356753089435529e-21 2.509685106383402275e-24 8.597380753983609396e-21 1.159189422052132654e-22 3.170241834247600231e-22 1.442180892924055572e-21 2.442355013022619406e-21 0.000000000000000000e+00 5.705457063028380198e-22 5.400281716297232487e-21 1.273353694593942270e-21 2.943274881306219275e-20 1.496500083528230221e+02 3.167869706731205570e-20 2.720590322571265340e-20 4.048378098558315250e-21 2.497990838197363879e-24 8.593199366749406612e-21 1.156101986137657258e-22 3.164140983377741016e-22 1.441962742288786060e-21 2.275980468881053625e-21 0.000000000000000000e+00 5.793771919476341571e-22 4.847069295903278333e-21 1.275053810550638286e-21 2.938063929370077844e-20 1.498500083416747941e+02 3.028581753140580604e-20 2.721191552900323587e-20 4.615476679509302761e-21 2.482399359643757805e-24 8.587603229310019095e-21 1.151985647334509329e-22 3.156006968951239840e-22 1.441660768875481801e-21 2.619768849847361849e-21 0.000000000000000000e+00 5.847959271329205976e-22 4.839406259253864279e-21 1.277320505477867520e-21 2.949552072982637535e-20 1.500000000000000000e+02 3.104024888367195122e-20 2.721642904297570173e-20 4.843615482984540455e-21 2.470885106383383651e-24 8.583430673431844941e-21 1.148898574556185589e-22 3.149906797047849121e-22 1.441439190495291592e-21 2.652475627474947048e-21 0.000000000000000000e+00 5.891195037294276408e-22 5.067345943543746786e-21 1.279020432227885451e-21 2.957628529241618945e-20 1.501500083250080877e+02 3.053644497622190062e-20 2.722094694572454191e-20 4.630748162863451626e-21 2.459369573689140165e-24 8.579415656456054758e-21 1.145811167235874762e-22 3.143805947309225484e-22 1.441246678921107966e-21 2.602942451430110117e-21 0.000000000000000000e+00 5.964837166351090980e-22 6.288727767286017592e-21 1.280720547869341529e-21 2.977480076318138505e-20 1.503500083139339267e+02 3.226956684090133745e-20 2.722697652470754797e-20 4.209756426643512244e-21 2.444096884076454526e-24 8.574062630560411983e-21 1.141694866143970576e-22 3.135671932879712222e-22 1.440990662086764360e-21 2.698122070287751997e-21 0.000000000000000000e+00 6.063265342376058511e-22 5.561960371225002691e-21 1.282987242797410160e-21 2.957975021815056531e-20 1.505000000000000000e+02 3.118204567047650648e-20 2.723150298804095310e-20 3.876003693361430578e-21 2.432985000000388376e-24 8.569999202303663184e-21 1.138607821345303396e-22 3.129571759848098482e-22 1.440799148513496647e-21 2.959992281570227969e-21 0.000000000000000000e+00 6.087725766805829210e-22 6.230381869148941884e-21 1.284687169861828443e-21 2.969528747529653520e-20 1.506500082973778092e+02 3.146125202203210286e-20 2.723603383346607647e-20 3.658068577345189686e-21 2.421871885302977402e-24 8.565861858433259271e-21 1.135520443379601597e-22 3.123470911233200425e-22 1.440608032618543284e-21 2.513032373380509490e-21 0.000000000000000000e+00 6.122373705997289576e-22 6.061665086871606144e-21 1.286387285190137529e-21 2.959445131090894713e-20 1.508500082863769762e+02 3.034942231779728405e-20 2.724208065946862222e-20 3.502097165122403510e-21 2.407031722650059844e-24 8.560345710047041835e-21 1.131404181030804200e-22 3.115336896800704698e-22 1.440353877405376103e-21 2.599653780377579983e-21 0.000000000000000000e+00 6.161522349888346887e-22 7.043191031224706912e-21 1.288623092588115051e-21 2.980376777687739085e-20 1.510500082754052755e+02 3.100344674648665862e-20 2.724813437624645486e-20 3.464463754284324570e-21 2.392121085170156330e-24 8.554865110376077043e-21 1.127287934476620577e-22 3.107202882367024073e-22 1.440065924969880278e-21 2.379023724052161583e-21 0.000000000000000000e+00 6.228847290551191439e-22 6.611488649994817191e-21 1.290841327884408876e-21 2.968598821640333918e-20 1.512000000000000171e+02 2.839434461942676449e-20 2.725267893254684252e-20 3.436056473654777135e-21 2.380938723404620093e-24 8.550761559367296900e-21 1.124200930178830021e-22 3.101102707768446271e-22 1.439843978410841292e-21 2.641036145043230758e-21 0.000000000000000000e+00 6.207843760444151566e-22 7.518168503629072457e-21 1.292504912663910888e-21 2.992267286028034274e-20 1.513500082590020952e+02 3.165564990611677414e-20 2.725722786157212194e-20 3.453268298439527599e-21 2.369959405352210058e-24 8.546659832951543453e-21 1.121113594640830283e-22 3.095001860714292030e-22 1.439624579732828352e-21 2.539962727525506592e-21 0.000000000000000000e+00 6.216906912839705188e-22 6.223417271442872372e-21 1.294168680829452783e-21 2.962012011943937546e-20 1.515500082481026993e+02 3.099654042244743079e-20 2.726329878519679240e-20 3.404780828110593235e-21 2.355559406136959842e-24 8.541232705171833878e-21 1.116997388338557813e-22 3.086867846277671258e-22 1.439373017945894618e-21 2.562986346913131208e-21 0.000000000000000000e+00 6.205302610907092342e-22 4.907981176559417612e-21 1.296386916126548578e-21 2.937235211799606327e-20 1.517000000000000171e+02 3.076977596415643536e-20 2.726785623921350138e-20 3.185068643051989411e-21 2.344760000000348103e-24 8.537162590532655440e-21 1.113910413959173232e-22 3.080767670568695632e-22 1.439184846969730892e-21 2.726113091561059518e-21 0.000000000000000000e+00 6.297070305307734897e-22 6.686531203827190326e-21 1.298050501208868278e-21 2.971473081144152409e-20 1.518500082318074931e+02 3.087857132837551411e-20 2.727241805925875205e-20 3.367120261053870492e-21 2.333916850615818649e-24 8.533114332878253226e-21 1.110823109717883742e-22 3.074666824620548039e-22 1.438997075557813055e-21 2.474118628757804651e-21 0.000000000000000000e+00 6.118956994463431783e-22 6.309706902117943204e-21 1.299714269072789796e-21 2.963294208560221709e-20 1.520500082209797199e+02 2.904524651516643161e-20 2.727850616101425363e-20 3.835243729637912358e-21 2.319431745017041502e-24 8.527761579101681932e-21 1.106706944793517648e-22 3.066532810181013922e-22 1.438747381396474307e-21 2.379569837214315039e-21 0.000000000000000000e+00 6.098861065534919495e-22 6.851348859378618135e-21 1.301932504370680037e-21 2.980596110090781832e-20 1.522500082101803969e+02 2.958369842500566769e-20 2.728460112597775635e-20 4.017018953653840297e-21 2.305024426656068173e-24 8.522408862888397117e-21 1.102590796745018888e-22 3.058398795740322648e-22 1.438498433231514769e-21 2.339968355162555613e-21 0.000000000000000000e+00 6.025653092679110323e-22 6.850330082964472309e-21 1.304150739668885874e-21 2.983049947802647014e-20 1.524000000000000057e+02 3.074457622628693892e-20 2.728917660060533718e-20 4.210039823164761074e-21 2.294550000000327371e-24 8.518427256529672499e-21 1.099503865701866077e-22 3.052298618489044831e-22 1.438280511107709966e-21 2.125561735985783503e-21 0.000000000000000000e+00 5.955579268323354903e-22 7.101365231516633616e-21 1.305814325171808362e-21 2.990264786548219596e-20 1.525500081940345183e+02 3.121031441033911178e-20 2.729375643187875632e-20 4.462121249490924395e-21 2.284074427783579685e-24 8.514445221005393282e-21 1.096416606730309189e-22 3.046197774077126355e-22 1.438062977998867337e-21 2.327641107376556607e-21 0.000000000000000000e+00 5.990508879740289207e-22 7.162089524480782734e-21 1.307458826262372554e-21 2.997182074061889899e-20 1.527500081833058516e+02 3.000676935679336970e-20 2.729986853474202058e-20 4.656049075177018203e-21 2.270157770049431584e-24 8.509103673046070221e-21 1.092300501707752362e-22 3.038063759633561703e-22 1.437782053844739438e-21 2.099682147226816912e-21 0.000000000000000000e+00 5.985893514710323203e-22 6.310244896759465722e-21 1.309629156456707442e-21 2.979663077840863526e-20 1.529000000000000057e+02 3.127565440432521316e-20 2.730445685536589862e-20 4.289473381331235998e-21 2.259833333333646982e-24 8.505000365839962778e-21 1.089213602699389067e-22 3.031963581289293722e-22 1.437597236414956871e-21 1.792379355231568828e-21 0.000000000000000000e+00 5.922340219673723022e-22 8.243396512498525304e-21 1.311256815387392937e-21 3.019395312776937934e-20 1.530500081672653891e+02 3.016121794601123586e-20 2.730904952592829310e-20 4.091698975674419592e-21 2.249507771153542951e-24 8.500896617564994417e-21 1.086126377147186414e-22 3.025862737966077676e-22 1.437412820410610304e-21 1.994327655298962514e-21 0.000000000000000000e+00 6.013492517309923962e-22 7.837662188994324139e-21 1.312884651748779936e-21 3.007411717858450014e-20 1.532500081566066399e+02 3.023355126087101538e-20 2.731517873793504224e-20 4.449495525775678788e-21 2.235805279364104402e-24 8.495498336183136519e-21 1.082010316381680624e-22 3.017728723519669739e-22 1.437167601844597275e-21 2.473653184785383903e-21 0.000000000000000000e+00 6.040156645778390466e-22 8.025618948823742083e-21 1.315054981943873535e-21 3.021394456310839536e-20 1.534500081459756586e+02 3.039660338390237374e-20 2.732131478554385574e-20 3.747588261862652455e-21 2.222221946752785773e-24 8.490189385109510568e-21 1.077894273674248121e-22 3.009594709072131916e-22 1.436941266658787149e-21 3.003223783962075281e-21 0.000000000000000000e+00 6.077371554309888802e-22 7.667233153423947407e-21 1.317225312139268624e-21 3.007755342095966832e-20 1.536000000000000227e+02 2.992219623120621472e-20 2.732592105432058916e-20 3.614167187020364259e-21 2.212035000000293906e-24 8.486207894921452299e-21 1.074807421100371757e-22 3.003494529209641981e-22 1.436773648469992394e-21 3.175373233972456807e-21 0.000000000000000000e+00 6.074248484179898685e-22 6.390069888941145657e-21 1.318852971475048281e-21 2.978211379569588598e-20 1.537500081300810848e+02 3.030672645989017508e-20 2.733053166363820970e-20 3.733946010982997320e-21 2.202067222830901765e-24 8.482299381206036499e-21 1.071720243927138103e-22 2.997393687398714934e-22 1.436579433393810292e-21 3.096670143751730079e-21 0.000000000000000000e+00 6.158435723511870925e-22 6.926694243043019675e-21 1.320480807432924180e-21 2.991163993257848217e-20 1.539500081195191115e+02 3.041740969146077330e-20 2.733668478010510319e-20 4.106676694834485695e-21 2.188973345971362354e-24 8.477103408449560211e-21 1.067604247280456328e-22 2.989259672948370971e-22 1.436315511194958437e-21 2.982691173633346741e-21 0.000000000000000000e+00 6.218866508527166151e-22 7.520079800275902254e-21 1.322651137629068012e-21 3.009598590975142902e-20 1.541500081089845651e+02 3.009357199228570692e-20 2.734284471605382880e-20 4.121995841556846714e-21 2.175879465483050210e-24 8.471886631127769552e-21 1.063488269432811770e-22 2.981125658496911229e-22 1.436064642706935553e-21 3.004911711317295195e-21 0.000000000000000000e+00 6.232980334033071430e-22 6.883183607811123426e-21 1.324821467825509386e-21 2.995177291703827681e-20 1.543000000000000114e+02 3.060670500490848857e-20 2.734746889067204275e-20 4.036113422395296083e-21 2.165992500000277917e-24 8.467937822350292278e-21 1.060401465234456680e-22 2.975025477129991180e-22 1.435898669107272558e-21 3.013852181815564744e-21 0.000000000000000000e+00 6.191226668986262146e-22 7.889425826368300677e-21 1.326437738824554297e-21 3.019123869603879169e-20 1.544500080932338335e+02 3.093947331191665151e-20 2.735209739642524501e-20 3.950249232895683690e-21 2.156104466521277848e-24 8.463988592975027588e-21 1.057314338389818642e-22 2.968924636817644517e-22 1.435733032821578215e-21 2.795715014443043993e-21 0.000000000000000000e+00 6.243649699301629399e-22 6.424954337144091190e-21 1.328038515019734624e-21 2.981259869146552099e-20 1.546500080827673571e+02 2.918390129641964744e-20 2.735827436091678177e-20 3.630393189982667165e-21 2.142967649267553923e-24 8.458701522949485359e-21 1.053198408505949779e-22 2.960790622363416251e-22 1.435512749162355332e-21 2.829283887214541526e-21 0.000000000000000000e+00 6.208343791341668901e-22 6.210465615973741179e-21 1.330172768014888432e-21 2.973371056732465119e-20 1.548500080723278529e+02 2.800470485297192875e-20 2.736445812875826653e-20 3.523358377354547128e-21 2.130249282584477574e-24 8.453392857627484566e-21 1.049082498203168765e-22 2.952656607908091483e-22 1.435293097520717592e-21 2.867113544400267894e-21 0.000000000000000000e+00 6.167911233301803556e-22 6.221640112008809986e-21 1.332307021010330001e-21 2.973096619947279753e-20 1.550000000000000000e+02 2.940783064668312146e-20 2.736910016687576525e-20 3.672707149910789278e-21 2.120711020408425385e-24 8.449411579155189802e-21 1.045995744428357026e-22 2.946556425050340379e-22 1.435128782550683029e-21 2.564412485918808033e-21 0.000000000000000000e+00 6.202096515073053551e-22 5.876346083468432129e-21 1.333907624698509290e-21 2.965430768336505221e-20 1.551500080567191162e+02 3.068084147920359782e-20 2.737374784049494144e-20 3.778941251376199031e-21 2.111159484370235199e-24 8.445538644747781333e-21 1.043044184040767872e-22 2.940674371755390529e-22 1.434935769627166096e-21 2.923740809548473233e-21 0.000000000000000000e+00 6.168162228566822398e-22 5.562658234664592101e-21 1.335508400504031483e-21 2.964357372017136944e-20 1.553500080463467725e+02 3.165705092747701739e-20 2.737995489590993666e-20 3.840384129118447839e-21 2.098359485034060772e-24 8.440385281163865059e-21 1.039580448874289239e-22 2.933593213978267134e-22 1.434676210881259591e-21 2.917371156675924563e-21 0.000000000000000000e+00 6.132450385284958095e-22 4.961120838920934332e-21 1.337642653500189822e-21 2.954817901403378528e-20 1.555500080360010884e+02 3.189521967989087967e-20 2.738616870062441432e-20 3.717035377596276801e-21 2.085559485696180042e-24 8.435192750480103542e-21 1.036116723846623708e-22 2.926512056200200053e-22 1.434431795903820634e-21 2.672384377646047158e-21 0.000000000000000000e+00 6.010630807707588173e-22 4.850785344782968242e-21 1.339776906496632536e-21 2.949496702113553380e-20 1.557000000000000171e+02 3.053914708581590678e-20 2.739083323085644478e-20 3.393546086616284975e-21 2.076180408163510609e-24 8.431244114632971348e-21 1.033519075828701186e-22 2.921201472112898865e-22 1.434269131168164377e-21 2.505705365694259686e-21 0.000000000000000000e+00 6.113457131857593181e-22 4.660931539775172921e-21 1.341377510572464471e-21 2.941409194410914009e-20 1.558500080205323570e+02 3.176941724761752112e-20 2.739550205258497854e-20 3.342080280449582044e-21 2.066910524772243773e-24 8.427295113162373848e-21 1.030921155538963001e-22 2.915890319531335954e-22 1.434106805422962112e-21 2.780394291663091543e-21 0.000000000000000000e+00 6.005237528682853044e-22 4.566629494397968216e-21 1.342978285991828119e-21 2.942114157877690424e-20 1.560500080102529239e+02 3.127454965657430767e-20 2.740173271045149260e-20 3.601953987806126624e-21 2.054551341733997301e-24 8.422091630567006374e-21 1.027457456307716953e-22 2.908809161750923056e-22 1.433890937277115122e-21 2.808024506474430666e-21 0.000000000000000000e+00 5.910812616060291151e-22 4.189810922770011252e-21 1.345106980633081257e-21 2.940255224262831001e-20 1.562500079999998093e+02 2.942773680727362523e-20 2.740797010153804444e-20 4.272952064975773475e-21 2.042335839347185332e-24 8.416938518811934408e-21 1.023993767578444759e-22 2.901728003969578226e-22 1.433675703205148364e-21 2.677987218431368371e-21 0.000000000000000000e+00 6.017693546497239977e-22 3.060277508042596265e-21 1.347197409378204617e-21 2.934559414511376835e-20 1.564500079897728995e+02 3.124724885591864651e-20 2.741421422124872725e-20 4.677733694526200958e-21 2.030156248133245242e-24 8.411785416726472201e-21 1.020530089458083842e-22 2.894646846187305695e-22 1.433452798171730047e-21 2.691060500729793460e-21 0.000000000000000000e+00 6.049904563978365034e-22 3.377187189682977350e-21 1.349287838123601820e-21 2.944760184639928675e-20 1.566000000000000227e+02 3.150943572477990110e-20 2.741890147438418118e-20 4.349709227497367135e-21 2.021064000000227532e-24 8.407920815527517906e-21 1.017932476132002766e-22 2.889336260463258398e-22 1.433261131919299396e-21 2.746960144121063205e-21 0.000000000000000000e+00 6.069804077962310509e-22 3.061009908556386698e-21 1.350855576252560808e-21 2.937117897915309511e-20 1.567500079744814627e+02 3.098730890635617209e-20 2.742359300692957987e-20 3.777685172169842048e-21 2.012243531100715808e-24 8.404055894994550676e-21 1.015334592406768091e-22 2.884025109512164457e-22 1.433069795467390845e-21 2.994844973778322088e-21 0.000000000000000000e+00 6.147853723383257534e-22 2.836425208000946694e-21 1.352423481242209011e-21 2.929711772512135457e-20 1.569500079643196386e+02 3.138505883001067033e-20 2.742985392808847685e-20 3.467331616371051813e-21 2.000483531698227260e-24 8.398902949729124355e-21 1.011870941286157421e-22 2.876943951727587487e-22 1.432829777179903711e-21 2.856402575562454791e-21 0.000000000000000000e+00 6.246462268369778516e-22 2.922466313440281780e-21 1.354513909988286496e-21 2.925801759768409751e-20 1.571500079541837351e+02 2.937239482005874927e-20 2.743612156177987261e-20 3.575440667471860512e-21 1.988702387034583301e-24 8.393750004053792434e-21 1.008407301160372823e-22 2.869862793942092692e-22 1.432617385495968375e-21 2.746089259218835481e-21 0.000000000000000000e+00 6.242772077718613356e-22 2.411156202016255477e-21 1.356604338734634814e-21 2.921830395094205750e-20 1.573000000000000114e+02 3.146329560557903226e-20 2.744082644001614167e-20 3.816254760021225752e-21 1.979837551020622305e-24 8.389885492374585223e-21 1.005809715969968263e-22 2.864552206957983629e-22 1.432458517287010512e-21 2.855007406348270125e-21 0.000000000000000000e+00 6.311906741185176972e-22 1.932815803509641472e-21 1.358172077235576827e-21 2.922716076541688666e-20 1.574500079390280689e+02 3.240144473994253463e-20 2.744553558825424789e-20 4.082654379573427337e-21 1.970971775685410205e-24 8.386041852914132040e-21 1.003211861836125735e-22 2.859241057262144151e-22 1.432299989949747111e-21 2.889803942243877444e-21 0.000000000000000000e+00 6.283494131442589327e-22 2.129401747674311335e-21 1.359739981854661250e-21 2.928350264192177954e-20 1.576500079289563701e+02 3.108115362963633426e-20 2.745181998315346552e-20 4.232312820740953088e-21 1.959309947098219917e-24 8.380931481315508895e-21 9.997482496982529593e-23 2.852159899474376420e-22 1.432089187983001340e-21 3.005811953212579974e-21 0.000000000000000000e+00 6.250186604012837599e-22 2.069593929267890852e-21 1.361830410601680635e-21 2.931655651718987565e-20 1.578500079189101655e+02 3.075638605933542378e-20 2.745811107448460020e-20 4.015514696144338863e-21 1.947885947672055634e-24 8.375837107606051064e-21 9.962846489600643785e-23 2.845078741685705909e-22 1.431881769344369151e-21 2.877593691134512282e-21 0.000000000000000000e+00 6.352395606902024628e-22 2.053298609618879438e-21 1.363917183052554881e-21 2.927675543971989993e-20 1.580500079088893983e+02 3.049305387904415149e-20 2.746440885764593120e-20 3.832517343096387542e-21 1.936461948244438514e-24 8.370833156894534249e-21 9.928210597408737271e-23 2.837997583896134500e-22 1.431650977771849947e-21 2.652406490928172592e-21 0.000000000000000000e+00 6.397175094801045193e-22 1.797191040697678223e-21 1.365964258274781876e-21 2.921871097454180385e-20 1.582000000000000171e+02 2.982015080617996336e-20 2.746913633462545218e-20 4.114648867700931015e-21 1.927859591836932199e-24 8.367080421108688557e-21 9.902235122938247117e-23 2.832686995308343633e-22 1.431478229961103299e-21 2.914659597819966858e-21 0.000000000000000000e+00 6.342552747575687475e-22 1.762283493284776336e-21 1.367499483817915262e-21 2.928317297601735564e-20 1.583500078939057119e+02 3.125312984715563285e-20 2.747386806950163043e-20 3.976750022278198997e-21 1.919250975558096744e-24 8.363290061722059112e-21 9.876256977753278799e-23 2.827375847210096898e-22 1.431315931466599269e-21 2.732472557820443300e-21 0.000000000000000000e+00 6.324810077626228582e-22 1.731647271243889631e-21 1.369034871108608083e-21 2.924808111513483801e-20 1.585500078839480977e+02 3.007485797417750489e-20 2.748018256210154565e-20 3.608892914712838009e-21 1.907773425109130760e-24 8.358137245694377215e-21 9.841621378866683704e-23 2.820294689418289698e-22 1.431127138496061086e-21 2.912884662848571431e-21 0.000000000000000000e+00 6.361937056530265992e-22 1.804549982357282563e-21 1.371081946331481506e-21 2.922680722667699088e-20 1.587500078740155516e+02 2.980787949699366529e-20 2.748650373042039859e-20 3.577950715445195458e-21 1.896665963464767043e-24 8.352984500623273345e-21 9.806985899479568902e-23 2.813213531625595235e-22 1.430938870003344586e-21 2.727717392429347173e-21 0.000000000000000000e+00 6.286901537564984246e-22 1.612291672973971387e-21 1.373129021554611469e-21 2.919827013696543632e-20 1.589500078641080165e+02 3.133435177793347177e-20 2.749283156985356159e-20 3.844817366888592969e-21 1.885577964014037689e-24 8.348003303756231601e-21 9.772350540862595591e-23 2.806132373832014920e-22 1.430751126195494198e-21 3.059771139721055578e-21 0.000000000000000000e+00 6.237800518492622374e-22 1.498093624384857155e-21 1.375176096777997595e-21 2.926345174908002462e-20 1.591000000000000227e+02 2.970267452766598351e-20 2.749758157567002473e-20 4.313041291676998143e-21 1.877294400000182510e-24 8.344281903278870294e-21 9.746375462520922866e-23 2.800821783658703167e-22 1.430610670137788497e-21 2.375531818549779618e-21 0.000000000000000000e+00 6.192043847710409340e-22 1.455045622236611745e-21 1.376711322779485381e-21 2.926636313448763847e-20 1.592500078492933824e+02 3.082688654691094092e-20 2.750233582726839579e-20 4.794651340037618647e-21 1.869097971114791139e-24 8.340560138346916142e-21 9.720397732205282269e-23 2.795510637139992171e-22 1.430470493120989755e-21 2.967316966165712462e-21 0.000000000000000000e+00 6.313172685403506944e-22 1.483563044248582101e-21 1.378246709613554130e-21 2.940017010759422940e-20 1.594500078394479203e+02 3.081085186475090552e-20 2.750868032433789372e-20 4.795630778035153617e-21 1.858169971652744052e-24 8.335556391295956326e-21 9.685762681192223164e-23 2.788429479344214151e-22 1.430243324128254659e-21 2.862019844457878120e-21 0.000000000000000000e+00 6.327408951523893784e-22 1.441263644519982096e-21 1.380293784837575588e-21 2.939241012170942033e-20 1.596500078296271283e+02 3.002413214051807125e-20 2.751503147640058472e-20 4.390620039278509658e-21 1.847313978453051114e-24 8.330552679829180826e-21 9.651127755541089761e-23 2.781348321547562504e-22 1.430016670002830077e-21 2.724296037755553213e-21 0.000000000000000000e+00 6.335760012588045627e-22 1.327250934188697195e-21 1.382340860061849448e-21 2.931518211908378008e-20 1.598500078198308927e+02 3.271071647128843944e-20 2.752138927884913281e-20 4.115952856111901458e-21 1.836545978980477181e-24 8.325549009745384148e-21 9.616492956606465328e-23 2.774267163750041461e-22 1.429814981540754057e-21 2.830133825502259331e-21 0.000000000000000000e+00 6.310861759371270941e-22 1.352087759758613951e-21 1.384358395393655264e-21 2.929105334918895933e-20 1.600000000000000000e+02 4.504748308383231990e-20 2.752616174355319587e-20 4.142537551341255434e-21 1.828470400000170459e-24 8.321796458061395155e-21 9.590518294304704635e-23 2.768956572009064111e-22 1.429676289192773236e-21 3.118351135001364229e-21 0.000000000000000000e+00 6.322650961875954096e-22 1.234490587347971853e-21 1.385869979264112930e-21 2.932236034484436956e-20 1.601500078051824687e+02 3.187221899385474605e-20 2.753093844191547999e-20 4.299355070620643949e-21 1.820458785388875348e-24 8.318043511164087103e-21 9.564540998809386170e-23 2.763645427052133718e-22 1.429537878287873427e-21 2.759772572519363544e-21 0.000000000000000000e+00 6.332617904822457820e-22 1.254640783781379269e-21 1.387381720599567319e-21 2.931334674369632792e-20 1.603500077954472829e+02 3.072523709055340029e-20 2.753731285016784050e-20 4.309922586267019114e-21 1.809834785906005582e-24 8.313069007985485728e-21 9.529906522721679119e-23 2.756564269252451646e-22 1.429353800435689939e-21 2.691232826197994075e-21 0.000000000000000000e+00 6.324337727583555507e-22 1.171907049092384866e-21 1.389397270737148655e-21 2.930973847526445532e-20 1.605500077857363408e+02 2.972785458736624266e-20 2.754369389267594944e-20 4.008572490589585291e-21 1.799210786421848283e-24 8.308107010650860490e-21 9.495272178248051296e-23 2.749483111451910523e-22 1.429170248940556534e-21 3.046521657475602817e-21 0.000000000000000000e+00 6.344120907011813124e-22 1.303072978765299278e-21 1.391412820874974305e-21 2.931199948712716838e-20 1.607500077760495856e+02 3.033262656448719164e-20 2.755008156483002126e-20 3.524333904939281223e-21 1.788933718781616220e-24 8.303145170426322206e-21 9.460637966834025738e-23 2.742401953650513640e-22 1.428974990857486114e-21 2.554627727349533176e-21 0.000000000000000000e+00 6.327384391229418515e-22 1.327853644795874990e-21 1.393428371013043894e-21 2.920834799992806353e-20 1.609000000000000057e+02 3.151228340903005775e-20 2.755487641843295072e-20 3.532366574018696023e-21 1.781240000000157065e-24 8.299423993910310602e-21 9.434663741800313186e-23 2.737091360359424115e-22 1.428807493513286123e-21 2.456117839517894086e-21 0.000000000000000000e+00 6.324372925209718672e-22 1.241705318169794518e-21 1.394939955324718569e-21 2.920059519994807010e-20 1.610500077615645580e+02 3.110216283566558099e-20 2.755967549356210877e-20 3.563445590212970946e-21 1.773545484230491235e-24 8.295702436244299445e-21 9.408686902414231894e-23 2.731780216946820584e-22 1.428640269403998729e-21 2.716923787172202835e-21 0.000000000000000000e+00 6.296919206255080352e-22 1.235274692954473387e-21 1.396451696220602582e-21 2.923065512639061353e-20 1.612500077519378010e+02 3.086578490816201287e-20 2.756607971965985149e-20 3.489067852561862618e-21 1.763427843745412365e-24 8.290740640399116837e-21 9.374053030113801448e-23 2.724699059143299348e-22 1.428434083136115159e-21 2.880099131514581873e-21 0.000000000000000000e+00 6.300064173035219876e-22 1.273435441032821694e-21 1.398467246359276657e-21 2.924365585366840121e-20 1.614500077423349182e+02 2.880282531388732994e-20 2.757249055926529331e-20 3.062765931445129476e-21 1.753325883446135966e-24 8.285778854098797895e-21 9.339419296102204555e-23 2.717617901338932226e-22 1.428252890333840837e-21 2.885245459302696632e-21 0.000000000000000000e+00 6.363398990415583955e-22 1.261801296363427957e-21 1.400482796498191285e-21 2.920072692163177464e-20 1.616500077327557960e+02 3.127042451029250512e-20 2.757890800776639778e-20 2.884477646507072107e-21 1.743203607176153961e-24 8.280817052658206506e-21 9.304785701923695196e-23 2.710536743533724390e-22 1.428072225031261618e-21 2.979542738318102539e-21 0.000000000000000000e+00 6.387348463589103881e-22 1.299580504019030335e-21 1.402475215200283374e-21 2.919848170572352130e-20 1.618500077232003207e+02 3.032086478133988440e-20 2.758533206055071313e-20 3.000187064901983238e-21 1.733043607661569900e-24 8.275956388631527782e-21 9.270152249145603483e-23 2.703455585727679132e-22 1.427892087428604816e-21 2.706246900753296165e-21 0.000000000000000000e+00 6.410514976900063364e-22 1.319573976448266831e-21 1.404456932211708128e-21 2.918924758598894861e-20 1.620000000000000000e+02 3.059873225112750455e-20 2.759015418326504479e-20 3.230571801021083983e-21 1.725424000000144138e-24 8.272311083464097312e-21 9.244178589472431180e-23 2.698144990565419832e-22 1.427757337574157737e-21 2.859844496808567939e-21 0.000000000000000000e+00 6.310449857165327000e-22 1.299976560992293886e-21 1.405943143515296945e-21 2.923093764355002248e-20 1.621500077089113461e+02 3.066928772234801845e-20 2.759498051266725373e-20 3.585026612376256571e-21 1.717928249563311701e-24 8.268660397923482800e-21 9.218202338590703529e-23 2.692833849017045017e-22 1.427620828929449196e-21 2.807177930653952623e-21 0.000000000000000000e+00 6.278750893642629955e-22 1.222556060186666730e-21 1.407429507729283861e-21 2.926730601769030222e-20 1.623500076994146752e+02 3.089861684772879703e-20 2.760142105597704516e-20 3.729200926278013728e-21 1.708124328460204372e-24 8.263698722497561981e-21 9.183569246326021635e-23 2.685752691208917724e-22 1.427401198181224653e-21 2.976488138433644497e-21 0.000000000000000000e+00 6.409047177905992636e-22 1.335596922857772060e-21 1.409411224741291473e-21 2.931198805332455800e-20 1.625500076899413955e+02 3.059874435946343717e-20 2.760787081691814652e-20 3.626714632633672539e-21 1.698320407355950936e-24 8.258737054385506074e-21 9.151836018231383167e-23 2.679159640485402636e-22 1.427194774204346274e-21 2.977731130608580487e-21 0.000000000000000000e+00 6.536369266437570412e-22 1.403151393572707930e-21 1.411392941753530798e-21 2.930744543580889062e-20 1.627500076804913647e+02 3.075579672034200797e-20 2.761432944766978858e-20 3.909935811906551306e-21 1.688616883226552172e-24 8.253867696782158302e-21 9.122648306848388040e-23 2.672995058905874063e-22 1.427017364527242123e-21 3.010551095820624933e-21 0.000000000000000000e+00 6.567234611867226782e-22 1.339620767079229622e-21 1.413374658766000520e-21 2.934907475358395936e-20 1.629500076710645544e+02 3.025358510192128841e-20 2.762079462872406917e-20 4.330136784818303429e-21 1.678938452310184879e-24 8.249048039920729519e-21 9.093460672463801726e-23 2.666830477325629850e-22 1.426854684411178731e-21 2.638221533391147500e-21 0.000000000000000000e+00 6.536146061307998338e-22 1.478470128880762911e-21 1.415356375778700263e-21 2.938361809967016512e-20 1.631000000000000227e+02 3.216195173195489430e-20 2.762564756232497400e-20 4.382121614451634528e-21 1.671680000000129200e-24 8.245433486855857544e-21 9.071571116120566868e-23 2.662207277367052163e-22 1.426732972624623847e-21 2.550385610875365931e-21 0.000000000000000000e+00 6.601575549533835665e-22 1.609720273901861175e-21 1.416842587598880855e-21 2.939421977350960196e-20 1.632500076569676821e+02 3.131885983721019793e-20 2.763050467206339143e-20 4.247149135983157824e-21 1.664675796324791497e-24 8.241818649031232389e-21 9.049679366888767280e-23 2.657583604953927464e-22 1.426611498845164249e-21 2.732954156023377241e-21 0.000000000000000000e+00 6.588489085003109522e-22 1.460275731489445420e-21 1.418328951298179356e-21 2.938659323066497145e-20 1.634500076475984827e+02 2.999216714352389482e-20 2.763698620875463795e-20 3.944684058078424589e-21 1.655337335223797794e-24 8.236999117589688327e-21 9.020491928275687444e-23 2.651419023371907784e-22 1.426449931761210052e-21 2.895830934248578126e-21 0.000000000000000000e+00 6.627883787228675402e-22 1.460658844894939139e-21 1.420299133716706302e-21 2.936495857162161102e-20 1.636500076382521911e+02 3.036062561660566218e-20 2.764347427965193154e-20 3.688806432964226937e-21 1.645990229387335964e-24 8.232179588308080716e-21 8.991304569306937831e-23 2.645254441789181867e-22 1.426278806217902352e-21 2.642479255011489273e-21 0.000000000000000000e+00 6.571668732907821543e-22 1.543668712103232279e-21 1.422245150891100293e-21 2.931672449655729497e-20 1.638500076289287222e+02 3.053605099235373904e-20 2.764996888015552557e-20 3.673884679537619579e-21 1.636594151393981203e-24 8.227360038909040968e-21 8.962117290760706280e-23 2.639089860205752534e-22 1.426078114999040403e-21 2.910675514102985461e-21 0.000000000000000000e+00 6.494889911671849091e-22 1.578448782326151276e-21 1.424191168065716406e-21 2.934676696397189618e-20 1.640500076196279906e+02 3.187607679109577688e-20 2.765647000566534841e-20 3.777755530298467510e-21 1.627198073399558395e-24 8.222540496649280584e-21 8.932930093425351008e-23 2.632925278621622137e-22 1.425877860615062944e-21 2.752963013974180654e-21 0.000000000000000000e+00 6.577368094734654141e-22 1.628665915584354113e-21 1.426137185240553887e-21 2.935251638689539335e-20 1.642500076103499111e+02 2.988431411699910180e-20 2.766297765158103351e-20 3.782130619948815961e-21 1.617993500761160847e-24 8.217798051002917577e-21 8.903742978099562828e-23 2.626760697036793496e-22 1.425710063175785010e-21 2.661665507884566481e-21 0.000000000000000000e+00 6.590019177761812859e-22 1.651601723432555746e-21 1.428083202415611610e-21 2.935085321176023037e-20 1.644000000000000057e+02 3.168797100693789749e-20 2.766786241455558843e-20 4.193242695792499653e-21 1.611186153846270752e-24 8.214255861136520970e-21 8.881853805513959556e-23 2.622137495206814696e-22 1.425590515537926115e-21 2.463942997129341631e-21 0.000000000000000000e+00 6.645747321060267912e-22 1.685321634176503368e-21 1.429542641315250842e-21 2.939512588487216379e-20 1.645500075964750692e+02 3.076337310732082508e-20 2.767275133615158792e-20 4.402898561576574403e-21 1.604378116775478111e-24 8.210713316082542175e-21 8.859962460651859301e-23 2.617513824658247851e-22 1.425471206791515870e-21 2.739314878360357789e-21 0.000000000000000000e+00 6.559769017262539430e-22 1.753088361838673973e-21 1.431002228178609710e-21 2.945752989831128347e-20 1.647500075872532648e+02 2.766853148368688884e-20 2.767927526295355335e-20 4.196410811194157512e-21 1.595282791514298502e-24 8.205913120709136539e-21 8.830775553913638681e-23 2.611349243071684651e-22 1.425312527086324889e-21 2.785558752228828675e-21 0.000000000000000000e+00 6.583120486031758974e-22 1.732263151575692744e-21 1.432948245354215119e-21 2.943541149010981995e-20 1.649500075780537713e+02 2.971844880899279421e-20 2.768580569405794049e-20 4.286797628072449300e-21 1.586169066443308650e-24 8.201093683931688026e-21 8.801588732064284510e-23 2.605184661484434021e-22 1.425154293862577746e-21 2.570666720291391310e-21 0.000000000000000000e+00 6.574591187377463615e-22 1.940470176454678987e-21 1.434894262530037571e-21 2.944673187843859754e-20 1.651500075688766458e+02 3.022825192763004758e-20 2.769234262486325133e-20 4.269470278079630733e-21 1.577055341371299423e-24 8.196307969621732031e-21 8.772401995951131905e-23 2.599020079896494081e-22 1.424982771015986166e-21 2.800155146661093516e-21 0.000000000000000000e+00 6.638249836442690056e-22 1.873991701446877191e-21 1.436840279706077630e-21 2.946586823978040901e-20 1.653500075597216323e+02 2.975710344810982496e-20 2.769888605076766885e-20 4.002017987500211021e-21 1.568225051406223856e-24 8.191584911979070211e-21 8.743215346432865384e-23 2.592855498307872355e-22 1.424786183186712795e-21 2.787298561432973819e-21 0.000000000000000000e+00 6.642317309047665266e-22 1.876051404194100632e-21 1.438776773685602952e-21 2.943214697977999829e-20 1.655500075505887878e+02 2.908022438863339640e-20 2.770543596716918947e-20 3.823388287967066812e-21 1.559409667193385455e-24 8.186861863426048422e-21 8.714028784379634062e-23 2.586690916718567431e-22 1.424590033685236911e-21 2.797489246506275837e-21 0.000000000000000000e+00 6.685781716556956286e-22 2.212464525856733837e-21 1.440695889714595710e-21 2.943775970429185186e-20 1.657000000000000171e+02 3.041462306904516225e-20 2.771035241372998057e-20 3.926480822095843594e-21 1.552810769230873908e-24 8.183286461040783725e-21 8.692140021645731487e-23 2.582067713046576289e-22 1.424466769083247583e-21 2.723030648789540444e-21 0.000000000000000000e+00 6.779712440057299833e-22 1.911641126526026136e-21 1.442135154349783482e-21 2.942718233910342634e-20 1.658500075369308036e+02 3.085792788402948028e-20 2.771527300138613940e-20 3.824611540415506893e-21 1.546291210895034150e-24 8.179702412813663122e-21 8.670249107229041981e-23 2.577444044333337456e-22 1.424349630375964860e-21 2.829958359200658247e-21 0.000000000000000000e+00 6.808335271076479869e-22 1.968409418756789879e-21 1.443574563758481036e-21 2.943136096184817535e-20 1.660500075278528982e+02 3.017627420364279297e-20 2.772183912389529265e-20 3.720887555444029221e-21 1.537598903597264179e-24 8.174923927784601354e-21 8.641062767722599331e-23 2.571279462742338880e-22 1.424193844714598525e-21 2.840424772425983633e-21 0.000000000000000000e+00 6.800455123284231860e-22 1.861408053800650860e-21 1.445493679788001167e-21 2.941702616841189628e-20 1.662500075187968207e+02 3.084179598262783864e-20 2.772841172079293252e-20 3.993910726400652640e-21 1.528977797134452191e-24 8.170231426088158539e-21 8.611876518820167341e-23 2.565114881150667451e-22 1.424003165851061587e-21 2.788360075799339388e-21 0.000000000000000000e+00 6.805981161919252690e-22 1.922894094956125193e-21 1.447412795817730631e-21 2.945675668082745437e-20 1.664500075097625427e+02 3.053763602436282781e-20 2.773499078747619478e-20 4.018868380244770136e-21 1.520570250344419831e-24 8.165548536963259898e-21 8.582690361446100696e-23 2.558950299558324580e-22 1.423809001427583320e-21 2.703001644690853509e-21 0.000000000000000000e+00 6.707330739141317993e-22 2.012738128422272580e-21 1.449331911847669238e-21 2.946294386800124210e-20 1.666500075007499220e+02 3.192315148355831889e-20 2.774157631934202861e-20 4.229020435560137095e-21 1.512162703553477014e-24 8.160865653975027069e-21 8.553504296537392995e-23 2.552785717965313558e-22 1.423630987455855300e-21 2.960376250029714196e-21 0.000000000000000000e+00 6.780407483555275475e-22 2.045467473479333854e-21 1.451251027877815673e-21 2.952443467952461427e-20 1.668500074917589018e+02 3.076849136551251973e-20 2.774816831178725682e-20 4.392648794797561600e-21 1.503741222655181224e-24 8.156182729857039095e-21 8.524318325043846027e-23 2.546621136371637206e-22 1.423476981931257829e-21 2.818264562638673519e-21 0.000000000000000000e+00 6.817230375004020788e-22 2.384041388083055362e-21 1.453170143908169372e-21 2.956485500117311329e-20 1.670500074827894252e+02 2.988123088596773315e-20 2.775476676020855777e-20 4.349397909057421367e-21 1.495310453802508461e-24 8.151499780691078835e-21 8.495132447928318967e-23 2.540456554777296934e-22 1.423323424489286619e-21 2.672854249769955209e-21 0.000000000000000000e+00 6.798564079791252546e-22 2.523032849952499660e-21 1.455089259938729769e-21 2.956143147043222725e-20 1.672500074738414071e+02 3.022357047683095164e-20 2.776137166000247138e-20 4.242809802916857194e-21 1.486879695405800643e-24 8.146816838083728556e-21 8.465946666166941150e-23 2.534291973182295095e-22 1.423178834208186454e-21 2.846166624282879808e-21 0.000000000000000000e+00 6.754368156736115818e-22 2.616625760282749994e-21 1.456998614695959033e-21 2.957514335599827066e-20 1.674000000000000057e+02 2.951545857983860479e-20 2.776632931889228784e-20 4.204505490322844053e-21 1.480766792452920828e-24 8.143304920468618862e-21 8.444058482684669459e-23 2.529668767144726426e-22 1.423075020760428370e-21 2.715062224445365420e-21 0.000000000000000000e+00 6.727598969730480309e-22 2.358760977444036279e-21 1.458411274976693589e-21 2.953932087927549718e-20 1.675500074604594261e+02 2.999916790547922889e-20 2.777129109594663390e-20 4.230523612669032648e-21 1.474653280856837762e-24 8.139792656478744673e-21 8.422168174482491351e-23 2.525045100788557832e-22 1.422971404129716218e-21 2.851467465565355419e-21 0.000000000000000000e+00 6.851884484925951968e-22 2.057837588970163175e-21 1.459824075911726612e-21 2.953743382670192358e-20 1.677500074515646702e+02 3.182345875295582388e-20 2.777791210403118531e-20 4.319623867100126538e-21 1.466502337823113101e-24 8.135192462427593023e-21 8.392982635466277050e-23 2.518880519191914062e-22 1.422798903239967164e-21 2.803824942349595412e-21 0.000000000000000000e+00 6.823416481486423513e-22 2.652229846875794393e-21 1.461707716722488539e-21 2.959806911491539399e-20 1.679500074426911169e+02 3.054549015860852369e-20 2.778453954737540559e-20 4.098950461488813076e-21 1.458309694849751296e-24 8.130601396571419569e-21 8.363797195328568575e-23 2.512715937594616717e-22 1.422622912622050738e-21 2.699722304430604556e-21 0.000000000000000000e+00 6.805293388950501076e-22 2.627320034371746588e-21 1.463591357533450205e-21 2.955975699400619796e-20 1.681500074338386810e+02 2.927033721773753622e-20 2.779117342137534717e-20 3.668258129731581502e-21 1.450109695212699893e-24 8.125992209647924043e-21 8.334611855108142056e-23 2.506551355996669089e-22 1.422460771172505821e-21 2.684664320081832810e-21 0.000000000000000000e+00 6.798150461050605014e-22 2.512686727173001502e-21 1.465474998344610672e-21 2.949679882840677487e-20 1.683500074250072771e+02 3.002547799183362049e-20 2.779781372142706246e-20 3.879039135743584464e-21 1.441978573726211228e-24 8.121349404884053727e-21 8.305426615858376787e-23 2.500386774398072588e-22 1.422324041050514275e-21 2.943126762134955703e-21 0.000000000000000000e+00 6.825790558428756344e-22 3.228801907532927135e-21 1.467358639155969374e-21 2.962296990532616394e-20 1.685500074161968200e+02 3.123216253641904065e-20 2.780446044292650161e-20 4.499109871625477048e-21 1.434054045773416512e-24 8.116706662906268465e-21 8.276241478647498558e-23 2.494222192798830505e-22 1.422187679713784967e-21 2.981455049666297547e-21 0.000000000000000000e+00 6.855371476198262258e-22 4.568624643006263196e-21 1.469242279967525182e-21 2.989469279862861533e-20 1.687500074074072529e+02 2.880535377557324212e-20 2.781111358126959665e-20 4.574738834367500569e-21 1.426129517819794358e-24 8.112107925950429389e-21 8.247056444558855894e-23 2.488057611198944721e-22 1.422051687268407297e-21 2.909929636480401197e-21 0.000000000000000000e+00 6.802021157134898160e-22 6.130521166840087224e-21 1.471125920779277722e-21 3.018213667768472921e-20 1.689500073986384905e+02 3.188964485729769148e-20 2.781777313185220743e-20 4.648355670107960562e-21 1.418277447162639070e-24 8.107516987532384335e-21 8.217871514691176311e-23 2.481893029598417588e-22 1.421916063820223717e-21 3.052305846330780290e-21 0.000000000000000000e+00 6.900230129236705810e-22 7.052072712895274366e-21 1.473009561591226240e-21 3.041302241119662242e-20 1.691500073898904759e+02 3.180945846869184781e-20 2.782443909007018777e-20 4.379242819309077071e-21 1.410473673919069735e-24 8.102910544693984493e-21 8.188686690158853138e-23 2.475728447997250986e-22 1.421769011268497009e-21 3.116925484994340427e-21 0.000000000000000000e+00 6.836311288176294585e-22 5.926319023094371505e-21 1.474890210038408620e-21 3.014304063661386920e-20 1.693500073811631239e+02 3.124101036308768014e-20 2.783111145131937344e-20 5.125430120621389367e-21 1.402669900674694085e-24 8.098267876384182686e-21 8.159501972092214709e-23 2.469563866395447737e-22 1.421594798795751498e-21 2.897981565262929382e-21 0.000000000000000000e+00 6.822696564851787086e-22 3.978017678980148008e-21 1.476738761500854153e-21 2.992290913562988692e-20 1.695000000000000000e+02 3.139519394273033043e-20 2.783611967514987211e-20 6.253770934122706262e-21 1.397001481481558325e-24 8.094786065248139714e-21 8.137614580227183833e-23 2.464940657501265106e-22 1.421464383344692904e-21 2.911689856489965752e-21 0.000000000000000000e+00 6.778254449416536508e-22 3.108028617536276389e-21 1.478125106935884345e-21 3.003922096405865922e-20 1.696500073681106642e+02 3.172224145570734625e-20 2.784113198880502783e-20 6.362288966903048413e-21 1.391345648120940321e-24 8.091331211745933548e-21 8.115725097128022788e-23 2.460316993991553732e-22 1.421345959677368776e-21 2.882577862183268929e-21 0.000000000000000000e+00 6.796714624992691383e-22 3.345118611539516443e-21 1.479511588694878767e-21 3.008844160070236904e-20 1.698500073594346418e+02 3.099523758291964204e-20 2.784782033748897968e-20 5.515075632516795281e-21 1.383804907707316435e-24 8.086779553986196602e-21 8.086540650277999063e-23 2.454152412388167797e-22 1.421211988751325277e-21 3.009327954856513702e-21 0.000000000000000000e+00 6.842736145829359045e-22 3.034721530177474859e-21 1.481360140157798446e-21 2.990531761029748213e-20 1.700500073507790262e+02 3.001203132768314606e-20 2.785451507308956804e-20 4.398540036514489832e-21 1.376225381325216429e-24 8.082227923115953494e-21 8.057356313979526805e-23 2.447987830784153207e-22 1.421078387424017892e-21 2.831431655427905993e-21 0.000000000000000000e+00 6.862506089394013284e-22 2.658653665381824536e-21 1.483208691620906957e-21 2.967129503888296421e-20 1.702500073421437605e+02 2.977170888600408174e-20 2.786121859185635892e-20 4.014293310213168105e-21 1.368632928822840782e-24 8.077676304853911576e-21 8.031059120998487336e-23 2.442320280813862313e-22 1.420916225844082189e-21 2.702507260780387908e-21 0.000000000000000000e+00 6.837126604701608811e-22 2.624843286184808228e-21 1.485057243084203548e-21 2.960679341548441425e-20 1.704500073335287311e+02 3.289064264054559317e-20 2.786792992430070769e-20 4.128278323960994228e-21 1.361052556219186106e-24 8.073124692108325845e-21 8.006509814671463621e-23 2.436953634958739366e-22 1.420744786360676120e-21 2.722073591369724523e-21 0.000000000000000000e+00 6.815407872895793682e-22 2.768628297442986975e-21 1.486905794547687088e-21 2.964243970903119789e-20 1.706500073249339380e+02 3.055050611827661877e-20 2.787464760827804461e-20 4.095451000991533061e-21 1.353580858427065867e-24 8.068580928992405669e-21 7.981960570220453613e-23 2.431586989103073341e-22 1.420581426749659933e-21 2.791853694726270206e-21 0.000000000000000000e+00 6.813416562473954998e-22 2.798858326379680766e-21 1.488754346011357768e-21 2.965236783258004871e-20 1.708500073163592390e+02 3.092289177295556088e-20 2.788137163919738001e-20 3.480277952697084591e-21 1.346109160634194964e-24 8.064068540658062654e-21 7.957411388218173442e-23 2.426220343246868000e-22 1.420449295707025830e-21 2.880829742723823318e-21 0.000000000000000000e+00 6.781266737628465385e-22 2.982523289007958059e-21 1.490602897475214081e-21 2.960526429545921062e-20 1.710500073078045773e+02 3.044372104293743838e-20 2.788810201246782653e-20 2.862984674389750485e-21 1.338753069711117112e-24 8.059556188850727914e-21 7.932862269244416888e-23 2.420853697390125222e-22 1.420317534805829133e-21 2.830794770013447356e-21 0.000000000000000000e+00 6.833486395541885056e-22 2.242971261152375710e-21 1.492451448939255653e-21 2.947406078083428709e-20 1.712500072992699245e+02 2.866444764322667464e-20 2.789483872349860515e-20 3.451169379693562934e-21 1.331538255204180799e-24 8.055075252675479180e-21 7.908313213886172933e-23 2.415487051532845479e-22 1.420186144149091859e-21 2.801755036561389530e-21 0.000000000000000000e+00 6.856896552407219318e-22 2.607767277252061315e-21 1.494281788990161921e-21 2.956943853076668788e-20 1.714500072907551669e+02 3.147315997716369581e-20 2.790158176769903916e-20 4.265953661672277116e-21 1.324323440696526698e-24 8.050611211930581911e-21 7.883764222737751537e-23 2.410120405675032061e-22 1.420055123839584941e-21 3.136100448074657034e-21 0.000000000000000000e+00 6.866448584075999141e-22 2.538834139289012481e-21 1.496107084406671936e-21 2.970825557873975912e-20 1.716500072822602760e+02 3.046183926581795687e-20 2.790833114047859630e-20 4.815302449812056264e-21 1.317175296091382808e-24 8.046144785620702521e-21 7.859215296400875327e-23 2.404753759816685439e-22 1.419922542756335799e-21 2.967346943579271954e-21 0.000000000000000000e+00 6.869220134786107617e-22 3.065721217533150326e-21 1.497932379823363447e-21 2.982955204609367795e-20 1.718500072737851383e+02 3.038315765389216414e-20 2.791508683724684060e-20 4.796023507886742200e-21 1.310049370467421667e-24 8.041632524728852846e-21 7.834666435484814782e-23 2.399387113957808434e-22 1.419753663386209425e-21 2.724988476519656277e-21 0.000000000000000000e+00 6.880701554828766891e-22 2.667013845188103339e-21 1.499757675240235138e-21 2.977015985712671737e-20 1.720500072653296968e+02 3.087967116498164331e-20 2.792184885341352266e-20 4.372947924604814513e-21 1.302928633795151887e-24 8.037120268970318165e-21 7.810117640606498723e-23 2.394020468098403397e-22 1.419586571757960881e-21 2.647724950421347136e-21 0.000000000000000000e+00 6.868901951936140443e-22 2.605141318907063214e-21 1.501582970657286632e-21 2.969764364879411685e-20 1.722500072568939231e+02 3.216371015398353942e-20 2.792861718438850745e-20 4.081802906697999622e-21 1.295906411869118507e-24 8.032651382499752744e-21 7.785568912390623641e-23 2.388653822238470327e-22 1.419448631033763503e-21 2.897313686767297207e-21 0.000000000000000000e+00 6.866270219239799616e-22 3.138320860208985173e-21 1.503408266074517742e-21 2.973626393499332102e-20 1.724000000000000057e+02 3.287093970936010994e-20 2.793369732829398434e-20 4.247172314000985990e-21 1.290640000000059639e-24 8.029332399873393842e-21 7.767158300315768844e-23 2.384629032399658003e-22 1.419359859034132190e-21 3.194802559048599680e-21 0.000000000000000000e+00 6.817141721053612217e-22 3.018512696445897885e-21 1.504777171465303635e-21 2.978128355570910002e-20 1.725500072442768840e+02 2.923119952993804912e-20 2.793878151107609114e-20 4.414321263246055220e-21 1.285373078978782371e-24 8.026013099298457765e-21 7.748745946444925725e-23 2.380603853447588480e-22 1.419271253407918530e-21 2.901801259212597032e-21 0.000000000000000000e+00 6.821075768069198399e-22 2.979136132293881429e-21 1.506146209200698435e-21 2.977557875504381294e-20 1.727500072358898819e+02 2.997595595792805459e-20 2.794556560899119039e-20 4.488190961667439658e-21 1.278451602079711305e-24 8.021587624002356757e-21 7.724197387670420530e-23 2.375237207586346851e-22 1.419153390485884047e-21 2.852710256176598913e-21 0.000000000000000000e+00 6.777989553247898351e-22 3.274175924384952369e-21 1.507971504618374540e-21 2.981798649166451622e-20 1.729500072275222635e+02 3.047368710923253108e-20 2.795235600565054913e-20 4.432329273465506871e-21 1.271547898664844440e-24 8.017162160832541120e-21 7.699648897807889272e-23 2.369870561724584712e-22 1.419035838717129935e-21 3.149611695423298158e-21 0.000000000000000000e+00 6.711692142584633348e-22 2.991638250326039177e-21 1.509796800036227440e-21 2.981493420359951484e-20 1.731500072191740003e+02 3.226323678970380498e-20 2.795915269646485685e-20 3.977704292078666883e-21 1.264676122122235326e-24 8.012736712155285120e-21 7.675100477518594541e-23 2.364503915862303476e-22 1.418918598178989805e-21 2.838110185815739809e-21 0.000000000000000000e+00 6.727033335682796846e-22 3.343167278373671281e-21 1.511610271538979552e-21 2.976213305386384776e-20 1.733500072108449785e+02 3.209873271906598626e-20 2.796595567684504981e-20 3.845242822461333184e-21 1.257985213309968707e-24 8.008311322077890278e-21 7.650552127472294227e-23 2.359137269999505962e-22 1.418771362495207858e-21 2.778367170455030559e-21 0.000000000000000000e+00 6.706620268087238336e-22 3.300503087572158182e-21 1.513403372802902350e-21 2.973955049668973814e-20 1.735500072025351415e+02 2.946571756393959682e-20 2.797276494220223280e-20 4.239682920403802946e-21 1.251294304497060342e-24 8.003885936726628214e-21 7.626003848347360244e-23 2.353770624136194051e-22 1.418616857714320003e-21 2.786279700741957242e-21 0.000000000000000000e+00 6.651519002697619159e-22 3.154609931603614466e-21 1.515196474066997052e-21 2.978320901064721745e-20 1.737500071942444606e+02 3.133489803080637431e-20 2.797958048794778142e-20 4.574954492005557407e-21 1.244589387689906070e-24 7.999460537235686531e-21 7.601455640830926637e-23 2.348403978272367745e-22 1.418470237084075592e-21 2.823368689661008532e-21 0.000000000000000000e+00 6.568482214696069916e-22 2.973349337440882675e-21 1.516989575331263470e-21 2.982274992950725072e-20 1.739500071859728507e+02 3.153072037256585549e-20 2.798640230949328193e-20 3.896587084133687650e-21 1.237863462042150717e-24 7.995035114334593919e-21 7.576907505619028298e-23 2.343037332408029863e-22 1.418354234182057118e-21 2.922188071312964033e-21 0.000000000000000000e+00 6.529662729249668962e-22 3.176072206595320024e-21 1.518782676595700852e-21 2.976196809064381377e-20 1.741500071777202265e+02 2.976315704724059593e-20 2.799323040225059142e-20 3.679496960703462638e-21 1.231137536393756925e-24 7.990609696403863067e-21 7.552359443416757302e-23 2.337670686543182287e-22 1.418238542914957231e-21 2.958908295446681374e-21 0.000000000000000000e+00 6.521192798571582531e-22 3.275262501476619122e-21 1.520575777860308446e-21 2.975401041035322232e-20 1.743500071694865312e+02 3.027847882064744910e-20 2.800006476163182579e-20 3.642539906810230558e-21 1.224578676538887877e-24 7.986207425285040756e-21 7.527811454938394561e-23 2.332304040677826898e-22 1.418100423935412576e-21 2.943476942343532064e-21 0.000000000000000000e+00 6.562112673790648197e-22 2.809339402258987865e-21 1.522368879125085875e-21 2.970567236765709125e-20 1.745500071612717079e+02 3.213829416259025961e-20 2.800690538304935371e-20 3.532877762435267674e-21 1.218091404078073132e-24 7.981820568957920827e-21 7.503263540907557942e-23 2.326937394811965105e-22 1.417947454496763955e-21 3.032563914669597707e-21 0.000000000000000000e+00 6.564041167362092496e-22 3.013067310018399923e-21 1.524161980390032388e-21 2.972670081547649670e-20 1.747500071530756998e+02 3.112584314302705584e-20 2.801375226191583272e-20 3.392139631349423061e-21 1.211604131616648048e-24 7.977433720171239433e-21 7.478715702057375059e-23 2.321570748945598320e-22 1.417794792176563820e-21 2.813809320545017863e-21 0.000000000000000000e+00 6.535430938008147369e-22 3.229249802820126484e-21 1.525955081655147607e-21 2.971678387822883059e-20 1.749500071448983931e+02 2.972785899149643746e-20 2.802060539364420929e-20 3.661177204530342365e-21 1.205185952661852269e-24 7.973129597125343439e-21 7.454167939130630212e-23 2.316204103078729834e-22 1.417680340254663722e-21 2.878798210583807776e-21 0.000000000000000000e+00 6.588750881999337593e-22 3.592703255611263430e-21 1.527748182920430593e-21 2.980203836837867610e-20 1.751500071367398164e+02 2.969918220776380238e-20 2.802746477364774282e-20 4.026984167502649692e-21 1.198771407468974390e-24 7.968825478717790918e-21 7.429620252879903098e-23 2.310837457211358707e-22 1.417566200367633348e-21 2.915143207513629612e-21 0.000000000000000000e+00 6.567117076134114838e-22 3.527452099485871764e-21 1.529530573093335786e-21 2.985025443613156935e-20 1.753500071285997990e+02 3.006399723264237402e-20 2.803433039733997559e-20 3.979975954849130077e-21 1.192377229540969687e-24 7.964478952393091940e-21 7.405072644067780395e-23 2.305470811343489640e-22 1.417452372590852169e-21 3.053727477967246944e-21 0.000000000000000000e+00 6.635482441731858993e-22 3.784184186316833303e-21 1.531291845350361226e-21 2.989473323149391942e-20 1.755500071204783694e+02 2.927933400894895385e-20 2.804120226013479294e-20 3.784061371114703438e-21 1.186064502524583376e-24 7.960053689664883645e-21 7.380525113466958033e-23 2.300104165475121694e-22 1.417338856999517967e-21 3.048105002821637458e-21 0.000000000000000000e+00 6.628011566076943795e-22 4.169213318779550899e-21 1.533053117607550482e-21 2.992525093104393392e-20 1.757500071123753855e+02 3.045131442601659616e-20 2.804808035744638716e-20 4.027477579295586473e-21 1.179751775507615197e-24 7.955628431398365910e-21 7.355977661860471591e-23 2.294737519606259099e-22 1.417225653668646468e-21 3.021556082972361088e-21 0.000000000000000000e+00 6.643013320036154446e-22 4.067789052025245530e-21 1.534814389864901862e-21 2.994574545277074838e-20 1.759500071042908473e+02 3.259196876595991825e-20 2.805496468468931164e-20 4.592601460699206998e-21 1.173484870288612815e-24 7.951322378158233761e-21 7.331430290041824423e-23 2.289370873736901386e-22 1.417084857160578838e-21 3.023509643597596129e-21 0.000000000000000000e+00 6.685246544062744761e-22 4.028575719839590779e-21 1.536575662122415931e-21 3.002734587202490240e-20 1.761500070962246696e+02 3.125963669353881685e-20 2.806185523727845681e-20 4.686031082649806681e-21 1.167273961448194061e-24 7.947056061382411341e-21 7.306882998815186322e-23 2.284004227867050906e-22 1.416935067839910281e-21 2.974675385432432585e-21 0.000000000000000000e+00 6.714611152409266611e-22 4.185158732760228602e-21 1.538336934380091560e-21 3.006375070885850615e-20 1.763500070881767954e+02 2.999036118642667729e-20 2.806875201062906820e-20 4.440801356640055212e-21 1.161063052607207212e-24 7.942785974374506921e-21 7.282335788995565136e-23 2.278637581996709540e-22 1.416789307601993504e-21 2.830812473510492349e-21 0.000000000000000000e+00 6.731767070543169250e-22 4.013528226235959610e-21 1.540098206637928561e-21 2.999458119444232223e-20 1.765500070801471395e+02 2.993745286221814946e-20 2.807565500015676449e-20 4.390991564159139624e-21 1.154989787089903463e-24 7.938481962428378964e-21 7.257788661408994852e-23 2.273270936125879168e-22 1.416677346266746710e-21 2.864166404781677297e-21 0.000000000000000000e+00 6.806069076767355738e-22 4.527491363378990648e-21 1.541859478895925805e-21 3.006906735038313405e-20 1.767500070721356735e+02 3.277933006153379995e-20 2.808256420127754352e-20 4.907254362124111115e-21 1.148975501616533273e-24 7.934177967538449094e-21 7.233241616892716620e-23 2.267904290254560260e-22 1.416565697584833894e-21 3.134784523118558656e-21 0.000000000000000000e+00 6.753301183646636525e-22 5.090240732301559186e-21 1.543620751154083292e-21 3.027048601522955966e-20 1.769500070641422838e+02 3.007176974444807311e-20 2.808947960940778229e-20 4.392321122896619727e-21 1.142961216142619601e-24 7.929873976948497873e-21 7.208694656295377409e-23 2.262537644382757049e-22 1.416454361630187256e-21 3.354814078238362095e-21 0.000000000000000000e+00 6.769055381791770596e-22 5.173882724894304024e-21 1.545382023412400083e-21 3.023453702439319447e-20 1.771500070561669702e+02 3.085237375527571109e-20 2.809640121996426107e-20 4.041668808326831094e-21 1.137024076549376589e-24 7.925570042844419833e-21 7.184147780477211040e-23 2.257170998510468124e-22 1.416347970022911492e-21 2.931219847280016484e-21 0.000000000000000000e+00 6.807500392543341398e-22 4.788319842360184982e-21 1.547139504531145084e-21 3.008316437833308105e-20 1.773500070482096191e+02 3.111686156766383290e-20 2.810332902836417538e-20 3.947513410641128624e-21 1.131095505356683193e-24 7.921266118600203338e-21 7.159600990310252119e-23 2.251804352637697716e-22 1.416247503706113716e-21 2.747410098155556981e-21 0.000000000000000000e+00 6.757222397247527979e-22 4.632291573994932160e-21 1.548880771104309233e-21 3.003414776010580840e-20 1.775500070402702306e+02 2.977845030677705346e-20 2.811026303002511195e-20 4.005113380975856542e-21 1.125163426435617620e-24 7.916992381317735498e-21 7.135054286678529996e-23 2.246437706764444885e-22 1.416117511025374460e-21 2.808052917583119887e-21 0.000000000000000000e+00 6.783938209780314414e-22 5.171104681991332010e-21 1.550622037677629863e-21 3.014063149093496780e-20 1.777500070323486625e+02 3.035024855645558696e-20 2.811720322036509688e-20 3.988472845767019340e-21 1.119199790308187546e-24 7.912726143655735788e-21 7.110507670478282708e-23 2.241071060890714333e-22 1.415980326924617673e-21 2.998873192244048268e-21 0.000000000000000000e+00 6.794803334511957454e-22 6.028141924578256960e-21 1.552363304251105471e-21 3.032094671848081234e-20 1.779500070244449432e+02 3.090407770020919765e-20 2.812414959480261366e-20 3.934083197415252793e-21 1.113236154180225193e-24 7.908471757374970866e-21 7.085961142618153281e-23 2.235704415016504650e-22 1.415848981627861675e-21 2.866355516776977420e-21 0.000000000000000000e+00 6.746899287307717783e-22 5.312687741287797707e-21 1.554104570824736620e-21 3.017216355316786561e-20 1.781500070165589591e+02 3.050638623660125155e-20 2.813110214875656106e-20 3.627285737455865763e-21 1.107344798023376036e-24 7.904284514539746525e-21 7.061414704019424834e-23 2.230337769141819126e-22 1.415749539016740664e-21 2.931315899406979554e-21 0.000000000000000000e+00 6.743868449141561196e-22 4.606437488537458239e-21 1.555845837398522182e-21 3.002898991213037247e-20 1.783500070086906533e+02 2.997039495844043616e-20 2.813806357115902548e-20 4.018744266382464986e-21 1.101587655392727197e-24 7.900097321093375117e-21 7.040379710342344121e-23 2.225594139442296322e-22 1.415650354217628456e-21 3.128047987638059777e-21 0.000000000000000000e+00 6.738539561305601744e-22 5.652209438645952604e-21 1.557587103972461593e-21 3.028173267357943312e-20 1.785500070008399689e+02 3.134350442218342374e-20 2.814503145819908350e-20 4.896993622148687875e-21 1.095830512761570875e-24 7.895857614536448300e-21 7.019748515079474875e-23 2.220922145511714738e-22 1.415534667396936197e-21 2.938453924950998623e-21 0.000000000000000000e+00 6.719287966452904658e-22 5.425939096208537406e-21 1.559328370546554476e-21 3.035595858874042919e-20 1.787500069930068491e+02 3.095618982997570950e-20 2.815200549476225862e-20 4.948095466589550973e-21 1.090120515984055098e-24 7.891553749088694299e-21 6.999117373475065118e-23 2.216250151580722202e-22 1.415398753342087903e-21 2.991141669560056494e-21 0.000000000000000000e+00 6.659351838946306227e-22 6.188007529552083101e-21 1.561069637120800268e-21 3.052002338930451822e-20 1.789500069851912656e+02 3.115364027214426315e-20 2.815898567627944458e-20 4.600426353490431364e-21 1.084449087634253500e-24 7.887249900389204758e-21 6.978486286005043125e-23 2.211578157649320593e-22 1.415263092110798520e-21 2.919315851174514761e-21 0.000000000000000000e+00 6.739992307117945221e-22 7.054773597010980967e-21 1.562810903695198780e-21 3.065202681507667886e-20 1.791500069773931330e+02 3.112040058765089100e-20 2.816597199818205266e-20 4.719161551154620537e-21 1.078777659283957092e-24 7.883069045837277885e-21 6.957855253150981894e-23 2.206906163717510853e-22 1.415157484270655673e-21 2.846044224076642859e-21 0.000000000000000000e+00 6.715453718463972039e-22 7.050179847024469215e-21 1.564552170269749072e-21 3.066749516348896057e-20 1.793500069696123660e+02 3.202353897623221812e-20 2.817296445590202982e-20 4.583657762303622913e-21 1.073233492485082768e-24 7.878918954161829440e-21 6.937224275400183785e-23 2.202234169785295802e-22 1.415059582513134643e-21 2.778465676762008904e-21 0.000000000000000000e+00 6.716911498159280830e-22 9.756457814685422269e-21 1.566266361547581174e-21 3.137947759539307472e-20 1.795500069618489363e+02 2.854882072755339573e-20 2.817996304487181050e-20 4.830916036775926708e-21 1.067731738312679964e-24 7.874765167591126325e-21 6.916593353245758097e-23 2.197562175852675911e-22 1.414961938907957558e-21 3.212139299883834359e-21 0.000000000000000000e+00 6.800264477354474258e-22 1.268220878485189369e-20 1.567978353454987534e-21 3.248988210490336523e-20 1.797500069541028154e+02 3.205070746349278551e-20 2.818696776052439491e-20 6.967385081508633782e-21 1.062229984139800902e-24 7.870578054489875799e-21 6.895962487186712764e-23 2.192890181919651180e-22 1.414864553508571608e-21 3.003472148920824178e-21 0.000000000000000000e+00 6.872357684666064281e-22 1.296260218858350165e-20 1.569690345362542099e-21 3.297023525068869093e-20 1.799500069463738612e+02 2.826544829496673442e-19 2.819397859829328879e-20 9.392039845973602780e-21 1.056716951335724379e-24 7.866390961681787985e-21 6.875331677728056613e-23 2.188218187986225840e-22 1.414767426368297593e-21 4.535365972473597548e-21 0.000000000000000000e+00 7.237150661097813074e-22 1.171396672287208003e-20 1.571402337270243554e-21 3.328400150398141058e-20 1.801500069386621306e+02 2.854999892943253627e-19 2.820099555361259372e-20 7.304771743817928474e-21 1.051202665834061600e-24 7.862203874510502905e-21 6.854700925380854623e-23 2.183546194052398011e-22 1.414655927556766970e-21 3.403297418571467746e-21 0.000000000000000000e+00 7.313422720801253265e-22 1.149342552019968393e-20 1.573114329178092463e-21 3.254557625635851629e-20 1.803500069309674529e+02 3.252200758508970166e-20 2.820801862191694092e-20 4.656722524655306838e-21 1.045706481840899278e-24 7.858016793461771687e-21 6.834070230662368977e-23 2.178874200118171924e-22 1.414522741828582347e-21 2.799603623598086104e-21 0.000000000000000000e+00 7.025703754100607552e-22 9.606313997709759087e-21 1.574826321086087322e-21 3.137310249845021197e-20 1.805500069232898284e+02 3.090211557255733467e-20 2.821504779864154541e-20 3.676680088203727186e-21 1.040373148712301811e-24 7.853829736925199485e-21 6.813439594096103732e-23 2.174202206183547110e-22 1.414389809562202862e-21 3.065772209148639117e-21 0.000000000000000000e+00 7.058785162620076876e-22 1.032209661670033102e-20 1.576538312994228318e-21 3.150032268225499774e-20 1.807500069156292000e+02 3.245055418122163530e-20 2.822208307922219395e-20 3.784944994719044866e-21 1.035039815583251411e-24 7.849668610090364905e-21 6.792809016211924723e-23 2.169530212248525449e-22 1.414282737529200760e-21 3.095470309164954971e-21 0.000000000000000000e+00 7.131081865981307370e-22 1.314918256009283787e-20 1.578250304902514511e-21 3.255707748782018175e-20 1.809500069079854825e+02 3.267076352118574145e-20 2.822912445909526916e-20 3.687382002395512545e-21 1.029724028737253638e-24 7.845518603123824455e-21 6.772178497546164176e-23 2.164858218313108822e-22 1.414186895786932894e-21 3.226094735840620807e-21 0.000000000000000000e+00 7.164730405775957103e-22 1.062914923317107841e-20 1.579962296810945713e-21 3.163036371971183578e-20 1.812000183958784305e+02 3.196598191901842498e-20 2.823793515951681448e-20 3.965300374562006419e-21 1.023144779055859691e-24 7.840330886586104319e-21 6.746389247334426529e-23 2.159017957313800621e-22 1.414058302221783776e-21 3.011948259041018018e-21 0.000000000000000000e+00 7.191048190857503819e-22 1.238123750655657546e-20 1.582102385114174657e-21 3.228022829291249800e-20 1.814500068889499858e+02 2.974732663390114888e-20 2.824675456323896788e-20 4.126389465215451177e-21 1.016566134501344234e-24 7.835143652874254563e-21 6.720602463541349344e-23 2.153178233472843274e-22 1.413893539883108629e-21 3.002693228033450668e-21 0.000000000000000000e+00 7.256416681901192290e-22 9.075385108459625977e-21 1.584174491485977954e-21 3.118911075944012442e-20 1.816500068813651581e+02 3.056152165701556154e-20 2.825381725470573343e-20 4.255544134693550342e-21 1.011378769177308810e-24 7.830993691332014679e-21 6.699972156459114126e-23 2.148506239536051319e-22 1.413762009502709697e-21 3.156771902366344328e-21 0.000000000000000000e+00 7.201794467858363688e-22 1.109968656046082887e-20 1.585821384337247294e-21 3.187418108464365989e-20 1.818500068737969571e+02 3.171109937548239401e-20 2.826088602493614346e-20 4.422114619087901503e-21 1.006199822004863880e-24 7.826904071235675983e-21 6.679341911091325618e-23 2.143834245598870510e-22 1.413660008436505523e-21 3.105703006286346996e-21 0.000000000000000000e+00 7.296669762902051528e-22 1.207506541887603826e-20 1.587468277188653367e-21 3.224976165284515406e-20 1.820500068662454112e+02 3.139364719223574584e-20 2.826796086937000512e-20 4.433156009630912476e-21 1.001024386013126383e-24 7.822829535645982935e-21 6.658711728011615661e-23 2.139162251661300847e-22 1.413565583006386678e-21 3.071760041617126252e-21 0.000000000000000000e+00 7.263245638807689616e-22 1.171320895949592332e-20 1.589115170040196550e-21 3.211951613574934521e-20 1.822500068587104352e+02 3.125150089850292755e-20 2.827504178344772741e-20 4.215325708554863037e-21 9.959156142757740037e-25 7.818755003689932886e-21 6.638081607800756046e-23 2.134490257723343741e-22 1.413471684799236333e-21 2.795591121569551471e-21 0.000000000000000000e+00 7.261540082063188060e-22 1.150020730424357993e-20 1.590762062891876090e-21 3.199305674566770612e-20 1.824500068511920006e+02 3.207589984659716490e-20 2.828212876261039944e-20 4.615122754795265875e-21 9.908068425379989977e-25 7.814680475373213346e-21 6.617451551046749030e-23 2.129818263785000604e-22 1.413385786106211457e-21 2.963469224466550200e-21 0.000000000000000000e+00 7.253169240478385602e-22 1.126690766526835401e-20 1.592408955743691988e-21 3.198565312934073221e-20 1.826500068436900222e+02 3.264568512377089046e-20 2.828922180229976632e-20 4.116381586880555998e-21 9.857149157866203021e-25 7.810605961411168897e-21 6.596821558344963695e-23 2.125146269846272844e-22 1.413300104062043032e-21 3.083342253877534172e-21 0.000000000000000000e+00 7.164488959988182008e-22 1.049738016725221747e-20 1.594055848595643490e-21 3.167070362906806670e-20 1.828500068362044146e+02 3.172458754523856359e-20 2.829632089795825327e-20 3.528838255697214563e-21 9.806903545711705914e-25 7.806531493785990806e-21 6.576191630298231159e-23 2.120474275907162814e-22 1.413203855869973692e-21 3.089500361776669191e-21 0.000000000000000000e+00 7.212305060626298747e-22 1.083807894723473365e-20 1.595702741447729657e-21 3.172062819418313518e-20 1.830500068287352065e+02 3.345928474339113232e-20 2.830342604502895957e-20 3.680645052297181926e-21 9.756657933553087230e-25 7.802457029578158734e-21 6.555561767516963305e-23 2.115802281967669807e-22 1.413082665746025561e-21 3.226972205700271754e-21 0.000000000000000000e+00 7.158088203002345320e-22 1.211764109816412282e-20 1.597349634299950865e-21 3.221598610025248614e-20 1.832500068212822839e+02 3.316730062272205701e-20 2.831053723895569469e-20 4.589630781049406012e-21 9.706908679494085761e-25 7.798382575774529736e-21 6.534931970619290311e-23 2.111130288027796176e-22 1.412961688086224398e-21 3.192706376813873896e-21 0.000000000000000000e+00 7.180090027925770453e-22 1.157856250993705448e-20 1.598996527152306174e-21 3.213627408099075462e-20 1.834500068138456186e+02 3.322513158692479904e-20 2.831765447518295424e-20 4.732848658225810963e-21 9.658081095102757283e-25 7.794308138303435163e-21 6.514302240231157040e-23 2.106458294087542859e-22 1.412860693985395609e-21 3.050235181959175476e-21 0.000000000000000000e+00 7.151344585263709686e-22 1.103768399457959854e-20 1.600627601326719529e-21 3.195767937360145518e-20 1.836500068064251820e+02 3.252721795967901377e-20 2.832477774915593795e-20 4.288007891719395018e-21 9.609253510707465184e-25 7.790233704177926159e-21 6.493672576986465278e-23 2.101786300146910329e-22 1.412776089855622453e-21 2.956639300436906148e-21 0.000000000000000000e+00 7.144207539462221342e-22 1.170532471697878349e-20 1.602245052731699858e-21 3.212858610844905263e-20 1.838500067990208038e+02 3.338319879357937641e-20 2.833190705632057986e-20 4.008550117095695374e-21 9.560798368235236560e-25 7.786159279245553351e-21 6.473042981527212441e-23 2.097114306205902815e-22 1.412691702624255863e-21 3.173096976619752367e-21 0.000000000000000000e+00 7.054635441859052302e-22 1.063465221023723976e-20 1.603862504136809963e-21 3.174378681387202491e-20 1.840500067916325690e+02 3.203975746867749486e-20 2.833904239212354221e-20 4.005871299142155844e-21 9.512798370008411150e-25 7.782113955628511444e-21 6.452413454503571506e-23 2.092442312264518203e-22 1.412578769862354578e-21 3.431774216370913814e-21 0.000000000000000000e+00 7.156963474604592395e-22 1.072414514364433489e-20 1.605479955542050782e-21 3.180608594071278667e-20 1.843000180864523543e+02 3.186782385764439397e-20 2.834797043660037873e-20 3.835313405154548096e-21 9.452795659251657387e-25 7.777066166504428250e-21 6.426625476988233378e-23 2.086602055775393277e-22 1.412428910459742746e-21 2.950261104316914970e-21 0.000000000000000000e+00 7.129639795338967644e-22 1.114514499619479560e-20 1.607501861217404072e-21 3.188813443808912941e-20 1.845500067732320701e+02 3.166865452667377683e-20 2.835690707704891931e-20 4.003559170148892222e-21 9.393522535711527774e-25 7.772018879618891127e-21 6.400839940692783064e-23 2.080762327409419092e-22 1.412299174555737115e-21 3.260295228622196995e-21 0.000000000000000000e+00 7.156613572080989508e-22 9.474061235345634558e-21 1.609523584055719607e-21 3.140189522496644829e-20 1.847500067658997409e+02 3.196850093254396751e-20 2.836406347723909649e-20 4.302944202419932327e-21 9.346212192618412687e-25 7.767980877281958321e-21 6.380210658435673977e-23 2.076090333466728506e-22 1.412215758006624504e-21 3.263213718982397189e-21 0.000000000000000000e+00 7.201406212524583269e-22 9.185735647006145312e-21 1.611141035461412568e-21 3.136174676581291471e-20 1.849500067585832994e+02 2.909200873666439185e-20 2.837122588558677962e-20 4.449029979536396802e-21 9.299005321102859699e-25 7.763942876187501603e-21 6.359581447645196029e-23 2.071418339523666699e-22 1.412132558583103714e-21 3.247979815435817381e-21 0.000000000000000000e+00 7.246038624586335934e-22 9.947195529802115203e-21 1.612758486867233988e-21 3.161743694345367130e-20 1.851500067512826320e+02 3.068534199801880941e-20 2.837839429754277171e-20 4.444227539227885628e-21 9.252384633149495874e-25 7.759962529682569797e-21 6.338952309019112088e-23 2.066746345580236491e-22 1.412049576323554917e-21 3.133739757340394356e-21 0.000000000000000000e+00 7.187119048709007350e-22 9.856121116160041521e-21 1.614375938273182925e-21 3.158208767771719861e-20 1.853500067439977101e+02 3.109179957433780124e-20 2.838556870855867624e-20 4.173967369562362970e-21 9.205763945192460465e-25 7.755996598963404438e-21 6.318323243264283347e-23 2.062074351636438354e-22 1.411966811266266693e-21 3.223081733761485356e-21 0.000000000000000000e+00 7.153268546636972707e-22 9.053279468203511049e-21 1.615993389679259191e-21 3.131822815295840772e-20 1.855500067367285340e+02 3.134566420959878942e-20 2.839274911408687909e-20 3.934661353295380187e-21 9.159281206850316963e-25 7.752030675453932247e-21 6.297694251096832720e-23 2.057402357692272523e-22 1.411884262237923210e-21 3.097139343139647137e-21 0.000000000000000000e+00 7.107910506217764749e-22 8.579874898715033462e-21 1.617599447588283203e-21 3.114629724769003297e-20 1.857500067294749897e+02 3.098497546361271223e-20 2.839993550958057262e-20 4.191994783937816292e-21 9.113212243003891273e-25 7.747992701828131106e-21 6.277065333242297654e-23 2.052730363747741348e-22 1.411765962204928010e-21 2.769067754876731863e-21 0.000000000000000000e+00 7.048901583877822826e-22 9.008368525627428239e-21 1.619189216127812169e-21 3.127517854208091061e-20 1.859500067222370490e+02 3.297516312361180977e-20 2.840712789049375567e-20 4.339934889662365423e-21 9.067143279153869306e-25 7.743954731338414981e-21 6.256436490435778243e-23 2.048058369802845769e-22 1.411647875324133108e-21 3.061179330716021561e-21 0.000000000000000000e+00 7.075312459252398566e-22 9.140843436540382897e-21 1.620778984667465267e-21 3.136655476137437603e-20 1.861500067150146833e+02 3.162436168017142653e-20 2.841432625228125767e-20 3.928675089388012448e-21 9.021632405068113241e-25 7.739934800001963787e-21 6.235807723422101799e-23 2.043386375857586493e-22 1.411538996263768607e-21 2.802849951258789192e-21 0.000000000000000000e+00 7.049913572574216987e-22 8.186732482147597055e-21 1.622368753207242121e-21 3.102838620951032795e-20 1.864000178826887009e+02 3.072529120418568918e-20 2.842333301105042913e-20 4.061801974702685341e-21 8.966036701341275019e-25 7.734977270165383151e-21 6.210020719591215786e-23 2.037546122338582908e-22 1.411436920432833276e-21 2.979950528024038141e-21 0.000000000000000000e+00 6.937636311301433573e-22 7.520249808181780401e-21 1.624356052723812179e-21 3.089992877596274478e-20 1.866500066970264129e+02 3.032946112474450897e-20 2.843234892234972378e-20 5.060583920226451712e-21 8.910445968390237804e-25 7.730020188256258067e-21 6.185118162829821110e-23 2.031868806378079620e-22 1.411335193485239043e-21 2.843610040237513086e-21 0.000000000000000000e+00 6.836303224377790687e-22 7.439551373336326730e-21 1.626343174557221974e-21 3.102166260055774752e-20 1.868500066898580769e+02 3.131056511191946755e-20 2.843957051601812049e-20 5.429803524697934929e-21 8.865777815507751586e-25 7.726054333469733549e-21 6.167773761795669156e-23 2.027801549497767971e-22 1.411220480335643356e-21 3.059473703573706351e-21 0.000000000000000000e+00 6.841084132010342761e-22 8.136890987745602746e-21 1.627932943097428213e-21 3.128430701259599250e-20 1.870500066827050318e+02 3.155549571520373413e-20 2.844679805787643276e-20 5.204187559332633962e-21 8.821088161933672599e-25 7.722088480054775088e-21 6.150429411542822610e-23 2.023734292617145286e-22 1.411104215056144039e-21 2.882884403060654220e-21 0.000000000000000000e+00 6.775162839721559314e-22 7.274537798796995555e-21 1.629522711637756139e-21 3.102119899857785986e-20 1.872500066755673060e+02 3.039428866723610074e-20 2.845403154339202056e-20 4.841694175947730765e-21 8.776398556267312200e-25 7.718127987839257654e-21 6.133085112502117786e-23 2.019667035736211095e-22 1.410993465868962406e-21 2.779650844127825815e-21 0.000000000000000000e+00 6.852352344415792739e-22 7.166350430493757240e-21 1.631112480178205752e-21 3.093367066989403190e-20 1.874500066684448143e+02 3.020866212786428531e-20 2.846127096803308649e-20 4.203416509096485484e-21 8.733144320519564077e-25 7.714197907153956396e-21 6.115740865109286929e-23 2.015599778854967279e-22 1.410912972434350521e-21 2.851250615501036475e-21 0.000000000000000000e+00 6.855843608203643446e-22 7.050662301137647380e-21 1.632702248718776487e-21 3.082586185580408554e-20 1.876500066613374997e+02 3.136851252887552117e-20 2.846851632726875396e-20 4.309307402004110077e-21 8.689890084768533753e-25 7.710267829340374671e-21 6.098396669805015818e-23 2.011532521973414544e-22 1.410835432026620742e-21 2.964072099157944504e-21 0.000000000000000000e+00 6.814915614744862345e-22 6.943853144888733289e-21 1.634287575696623995e-21 3.083257316123304785e-20 1.878500066542452771e+02 3.090780784590163482e-20 2.847576761656904917e-20 4.317738253474095473e-21 8.646669769876089033e-25 7.706361878523557758e-21 6.081052527035020174e-23 2.007465265091555004e-22 1.410762993083923299e-21 2.682942421607598181e-21 0.000000000000000000e+00 6.819556374146423771e-22 6.717190730927196108e-21 1.635850043059977709e-21 3.076352334579716268e-20 1.880500066471682032e+02 3.060038947565726268e-20 2.848302483140487099e-20 3.990190116795894328e-21 8.604093500196221900e-25 7.702500725987867054e-21 6.063708437250100903e-23 2.003398008209387484e-22 1.410690732325096307e-21 2.785205391674982800e-21 0.000000000000000000e+00 6.845706454330232371e-22 6.595832038814380175e-21 1.637412510423449726e-21 3.070796030638892053e-20 1.883000177022473451e+02 3.142920302025338526e-20 2.849210507787446237e-20 3.667127866750217768e-21 8.550870807792929173e-25 7.697674075812650510e-21 6.042027440762783848e-23 1.998313712107534719e-22 1.410600653009163907e-21 2.794779146402227999e-21 0.000000000000000000e+00 6.785209276354400201e-22 6.294105519490942313e-21 1.639365681062905130e-21 3.061225094811282719e-20 1.885500066295411159e+02 3.029329498458633346e-20 2.850119376299864390e-20 3.555958717044492852e-21 8.497978267689821169e-25 7.692778950103303907e-21 6.020348447602845077e-23 1.993229866002634382e-22 1.410475504533941251e-21 2.786912397866394412e-21 0.000000000000000000e+00 6.903144762697920083e-22 5.652546972931222502e-21 1.641318678832642188e-21 3.048053741895398943e-20 1.887500066225164517e+02 3.244602933563954960e-20 2.850847168155566274e-20 3.630018765641349325e-21 8.455944370861104463e-25 7.688848912366366798e-21 6.003004546891172775e-23 1.989162609119400925e-22 1.410368509605539394e-21 2.850880401401623896e-21 0.000000000000000000e+00 6.923026468211143218e-22 6.930531016043757187e-21 1.642881146196523653e-21 3.076359574936035062e-20 1.889500066155066236e+02 3.193293289665250400e-20 2.851575550527882681e-20 3.796727656115596781e-21 8.413910474029270860e-25 7.684932663619634621e-21 5.985660701258307435e-23 1.985095352235865835e-22 1.410268762192547836e-21 3.085874807002522831e-21 0.000000000000000000e+00 6.924917751465327728e-22 5.522803806339080023e-21 1.644443613560520974e-21 3.052640193961754061e-20 1.891500066085116600e+02 3.200526381937930852e-20 2.852304522964418685e-20 3.723466599145190261e-21 8.372765322936113059e-25 7.681071568555384665e-21 5.968316911184433796e-23 1.981028095352028409e-22 1.410197476928611571e-21 3.122906442382398938e-21 0.000000000000000000e+00 6.927677635298758218e-22 5.257670064005938509e-21 1.646006080924634528e-21 3.048021554877492857e-20 1.893500066015314474e+02 3.088511722158626764e-20 2.853034085012876260e-20 3.832135250044709008e-21 8.332098657688754917e-25 7.677210485641558904e-21 5.950973177155341356e-23 1.976960838467890996e-22 1.410126370037445254e-21 3.002099448684548275e-21 0.000000000000000000e+00 6.936365312348796315e-22 5.027826900248979378e-21 1.647568548288863375e-21 3.044870294217632224e-20 1.895500065945659571e+02 2.940708528329413645e-20 2.853764236221053675e-20 4.328631650216665283e-21 8.291431992438399264e-25 7.673349405444755362e-21 5.933629499662494899e-23 1.972893581583454302e-22 1.410043280371990584e-21 2.887131127187084223e-21 0.000000000000000000e+00 7.026674849828779845e-22 5.175118739262713284e-21 1.649131015653206950e-21 3.053482922981165158e-20 1.898000175623455164e+02 3.124510103853740776e-20 2.854677793177319056e-20 4.825413352088441732e-21 8.240464212701158197e-25 7.668522833837378445e-21 5.911949031202627594e-23 1.967809287256950654e-22 1.409911432750431868e-21 3.028982121006624868e-21 0.000000000000000000e+00 6.973968928652927289e-22 5.192826575116602924e-21 1.651083576547840119e-21 3.063318585234661281e-20 1.900500065772164078e+02 3.103938715996016645e-20 2.855592188848590391e-20 4.441473504371601764e-21 8.189449505259706011e-25 7.663696686375330837e-21 5.890270556553899370e-23 1.962725439371057182e-22 1.409779871279601963e-21 3.299415650905810018e-21 0.000000000000000000e+00 7.001014113683399096e-22 4.903988901931888119e-21 1.653017187046424133e-21 3.056283592343894394e-20 1.902500065703021335e+02 3.243102270354706418e-20 2.856324398556124032e-20 4.236209181866781381e-21 8.148905370127183352e-25 7.659870697431556808e-21 5.872927080892135204e-23 1.958658182485578765e-22 1.409709562460214990e-21 2.925582382710288125e-21 0.000000000000000000e+00 6.907241568297821590e-22 4.782350786629976115e-21 1.654564143365872941e-21 3.048198947350541366e-20 1.904500065634023542e+02 3.169425343434007151e-20 2.857057195389693592e-20 4.281278114026737642e-21 8.109438704822071333e-25 7.656044751020358213e-21 5.855583664050744780e-23 1.954590925599805534e-22 1.409639432173295549e-21 3.033910234707192350e-21 0.000000000000000000e+00 6.963942987219750334e-22 4.201386532087906426e-21 1.656111099685434033e-21 3.041931280320734333e-20 1.906500065565170701e+02 3.067185426260177340e-20 2.857790578897644428e-20 4.055843392050196884e-21 8.069972039514097719e-25 7.652213543104069311e-21 5.838240306553935101e-23 1.950523668713737724e-22 1.409569480445491062e-21 3.223859229857494627e-21 0.000000000000000000e+00 6.965924294150381404e-22 3.639818142883652526e-21 1.657658056005107032e-21 3.034148798932796813e-20 1.908500065496462241e+02 3.189508637451451242e-20 2.858524548628426614e-20 3.922296357889608946e-21 8.030585387302567701e-25 7.648352515517456213e-21 5.820897008932180907e-23 1.946456411827376276e-22 1.409499707303386698e-21 3.330491766042888788e-21 0.000000000000000000e+00 6.978639797011260549e-22 4.242664849038676030e-21 1.659205012324891750e-21 3.041970225928467061e-20 1.911000174428738205e+02 3.032887209291691369e-20 2.859442874543819625e-20 4.334342579344560608e-21 7.981749926158774048e-25 7.643526024228064124e-21 5.799217026562973828e-23 1.941372119016982454e-22 1.409412738266072684e-21 2.967380628898198419e-21 0.000000000000000000e+00 6.932663042610360449e-22 4.171611749882050688e-21 1.661138792047792595e-21 3.043561336415653506e-20 1.913500065325318928e+02 2.881691043493893731e-20 2.860362034717884524e-20 4.467054278793190172e-21 7.932918723978894287e-25 7.638728028190926811e-21 5.777539030369803185e-23 1.936288269610195599e-22 1.409298248058198011e-21 2.779901735717890145e-21 0.000000000000000000e+00 6.954493658606477468e-22 3.601131616617381455e-21 1.663072403124839071e-21 3.037176733913429632e-20 1.915500065257112112e+02 3.094341208381064882e-20 2.861098052674094277e-20 4.236660866983070604e-21 7.894412084747375514e-25 7.634902112291932389e-21 5.760195946580541866e-23 1.932221012722813822e-22 1.409194338694096640e-21 2.772476047341112871e-21 0.000000000000000000e+00 7.038327384346743590e-22 3.345519598734430856e-21 1.664619359445011796e-21 3.031503220013731507e-20 1.917500065189047120e+02 3.207986439395786367e-20 2.861834654822435450e-20 4.417959178496255426e-21 7.856145419383017290e-25 7.631076205861984692e-21 5.742852925133270794e-23 1.928153755835143813e-22 1.409090604651386136e-21 3.066074038278903252e-21 0.000000000000000000e+00 7.078350480271367294e-22 3.097818669012155778e-21 1.666166315765294359e-21 3.034900147339994823e-20 1.919500065121124237e+02 3.908535002544954402e-20 2.862571840711932286e-20 4.883282650815116135e-21 7.817878754015938899e-25 7.627312945455844843e-21 5.725509966594514771e-23 1.924086498947184633e-22 1.409020072409590862e-21 2.959583816315410725e-21 0.000000000000000000e+00 7.092906541524799755e-22 3.193434769726462058e-21 1.667713272085686761e-21 3.042566789298553280e-20 1.921500065053342894e+02 3.300688811552036684e-20 2.863309609891716160e-20 4.710105917115869278e-21 7.780326657367368503e-25 7.623553007259619323e-21 5.708167071537690519e-23 1.920019242058937692e-22 1.408951455893515949e-21 3.045326332890080699e-21 0.000000000000000000e+00 7.177101926490072364e-22 3.324245244026078192e-21 1.669240223197568039e-21 3.042711304150950869e-20 1.924000173250165631e+02 3.118414069320058293e-20 2.864232680930245909e-20 4.646467924512910649e-21 7.733767265374078355e-25 7.618852897698119447e-21 5.686487603923006823e-23 1.914934950744182697e-22 1.408855679667732859e-21 3.018017842985721867e-21 0.000000000000000000e+00 7.248415035102602158e-22 3.652441088403676763e-21 1.671142335134219472e-21 3.045999206356646494e-20 1.926500064884504582e+02 3.088788654216086351e-20 2.865156581778329097e-20 4.524057551020638426e-21 7.687198788822692465e-25 7.614153193728719428e-21 5.664810115455458178e-23 1.909851099837069614e-22 1.408727732414984603e-21 2.945765495876708047e-21 0.000000000000000000e+00 7.333061330988262863e-22 2.859359045195130501e-21 1.673044282307567549e-21 3.035735712622771576e-20 1.928500064817214366e+02 3.082328147977377885e-20 2.865896388925090337e-20 4.319263309014942669e-21 7.649865456745441073e-25 7.610393239376231726e-21 5.647467447202891515e-23 1.905783842947823973e-22 1.408625567697405014e-21 2.937390439011696876e-21 0.000000000000000000e+00 7.398515557188623200e-22 2.955174646954060362e-21 1.674565905951753702e-21 3.034216437836296516e-20 1.930500064750063984e+02 3.061367058184025385e-20 2.866636777334575542e-20 4.259172512140068108e-21 7.612532124665579716e-25 7.606633287594371493e-21 5.630124845100646432e-23 1.901716586058293862e-22 1.408545792264502223e-21 2.822494038700746088e-21 0.000000000000000000e+00 7.478004440804330838e-22 3.478888548964182144e-21 1.676087529596046308e-21 3.038458510069210577e-20 1.932500064683052017e+02 3.010894663338385216e-20 2.867377746556520346e-20 4.117869304191555957e-21 7.575388997518839498e-25 7.602873348682703624e-21 5.612782309761936015e-23 1.897649329168482338e-22 1.408483342409933834e-21 2.928575629529563890e-21 0.000000000000000000e+00 7.524067552792243101e-22 3.660073611639650372e-21 1.677609153240444426e-21 3.040266788172036311e-20 1.934500064616178747e+02 3.196543680465955674e-20 2.868119296140771726e-20 3.684831759766567407e-21 7.539323424954258817e-25 7.599113470511119665e-21 5.595439841807547058e-23 1.893582072278388695e-22 1.408421612691004729e-21 2.692004672518036533e-21 0.000000000000000000e+00 7.503950276066630743e-22 3.398853212694102311e-21 1.679130776884947868e-21 3.030081921234947059e-20 1.937000172087413148e+02 3.032227217860598796e-20 2.869047088503091751e-20 3.006024801012203267e-21 7.494239519735277024e-25 7.594447908314662972e-21 5.573760919957026462e-23 1.888497782439210835e-22 1.408310476862341251e-21 2.688245903292485666e-21 0.000000000000000000e+00 7.563893889961084799e-22 2.763633543603834995e-21 1.681032888269563081e-21 3.016851647829309264e-20 1.939500064449599108e+02 2.933455065460114205e-20 2.869975706233383772e-20 3.420562870453984765e-21 7.449395571784301889e-25 7.589791363024475186e-21 5.552083970871933807e-23 1.883413930051927255e-22 1.408191037796905378e-21 2.905892968255963105e-21 0.000000000000000000e+00 7.643730473299766473e-22 2.734472375862329192e-21 1.682934835996665669e-21 3.023807013112422056e-20 1.941500064383207871e+02 3.006815822375250631e-20 2.870719283542390685e-20 4.350598730889878677e-21 7.413723441820916272e-25 7.586053893749106515e-21 5.534741743763959378e-23 1.879346673160853485e-22 1.408107612226613527e-21 2.951546359203045835e-21 0.000000000000000000e+00 7.600435828513027991e-22 2.793964142557485179e-21 1.684456459641535866e-21 3.037322694762648605e-20 1.943500064316953058e+02 3.160380970497438562e-20 2.871463439189426016e-20 4.597227027177015283e-21 7.378051311855097015e-25 7.582294014942553986e-21 5.517399586931162052e-23 1.875279416269502064e-22 1.408046552324646278e-21 2.806889532798876503e-21 0.000000000000000000e+00 7.589831583316401426e-22 2.753917703328709822e-21 1.685961559669913897e-21 3.039832112216950655e-20 1.945500064250834384e+02 3.037134450973549471e-20 2.872208172724966882e-20 4.162263546769280371e-21 7.342739858690403750e-25 7.578534144545923633e-21 5.500057501038306217e-23 1.871212159377873931e-22 1.407985642289991207e-21 2.836668734591202831e-21 0.000000000000000000e+00 7.611546746697290551e-22 2.530432379891313499e-21 1.687458249211875789e-21 3.032513329238629640e-20 1.948000171115666603e+02 3.146766933706225383e-20 2.873139941493115224e-20 4.106548884236538817e-21 7.298967495876619535e-25 7.573858254988573602e-21 5.478379067120023491e-23 1.866127870771892852e-22 1.407909712284153381e-21 3.079099853309282845e-21 0.000000000000000000e+00 7.608648405178772469e-22 2.674313393700014171e-21 1.689329191172918724e-21 3.036125783442381892e-20 1.950500064086130863e+02 3.265350089013554130e-20 2.874072531877103333e-20 4.099628085938165064e-21 7.255198890574614272e-25 7.569201731227545667e-21 5.456702601107150792e-23 1.861044017147597306e-22 1.407834023000380931e-21 2.855509030059394466e-21 0.000000000000000000e+00 7.571101223669648730e-22 2.571859952225637033e-21 1.691199973067224481e-21 3.033727797994318723e-20 1.952500064020485695e+02 3.165746540987717378e-20 2.874819284484127880e-20 3.758132400772777304e-21 7.220575940891353962e-25 7.565479535289983888e-21 5.439360768861707783e-23 1.856976760255006208e-22 1.407771956078984551e-21 3.019046152597111644e-21 0.000000000000000000e+00 7.487135679006076654e-22 2.880346059328666305e-21 1.692696662609540714e-21 3.034262222302664803e-20 1.954500063954974678e+02 3.115709184833847865e-20 2.875566639923721815e-20 3.839567709675321245e-21 7.185952991205772051e-25 7.561817302432899460e-21 5.422432711441459621e-23 1.852987434277754021e-22 1.407678109198445003e-21 3.104032850349171547e-21 0.000000000000000000e+00 7.425513801704988994e-22 2.817912532995611655e-21 1.694193352151957382e-21 3.036161836761287579e-20 1.956500063889597811e+02 3.217427158470136760e-20 2.876314725451857276e-20 3.620645274180024364e-21 7.151330041517867620e-25 7.558155071840157951e-21 5.407885762607020298e-23 1.849446638041294490e-22 1.407584409436038213e-21 3.042101271791451718e-21 0.000000000000000000e+00 7.390850500420679620e-22 2.172790752203617296e-21 1.695690041694474296e-21 3.028149360481666880e-20 1.959000170154833711e+02 3.073977015161929574e-20 2.877250679397166527e-20 3.738210685928130107e-21 7.109339081273841274e-25 7.553577117900670925e-21 5.389701378760561144e-23 1.845020454469261383e-22 1.407479254666079082e-21 2.974467663961667928e-21 0.000000000000000000e+00 7.300503461126089737e-22 2.356771678022658559e-21 1.697560983206812417e-21 3.031043310964173000e-20 1.961500063726739143e+02 3.150316263163167851e-20 2.878187449755309273e-20 4.184863871688045452e-21 7.067405382648329538e-25 7.548999557913732040e-21 5.371518626835856341e-23 1.840594647449112404e-22 1.407404591145561185e-21 3.184137568409650356e-21 0.000000000000000000e+00 7.255984108562561082e-22 2.901455223320353135e-21 1.699431765551203676e-21 3.044480360883263401e-20 1.963500063661827255e+02 3.122612505514496540e-20 2.878937542494140613e-20 4.151032117869504397e-21 7.034037658230548500e-25 7.545337364040734740e-21 5.356971868208483536e-23 1.837053851211829557e-22 1.407345026589741702e-21 3.324983110094783611e-21 0.000000000000000000e+00 7.338679603451020563e-22 2.435577418656046756e-21 1.700928455094068536e-21 3.042084529854771503e-20 1.965500063597048097e+02 3.097199463012011404e-20 2.879688207714175187e-20 3.871987313618971513e-21 7.001005401235931311e-25 7.541675186118696995e-21 5.342425164925956749e-23 1.833513054974311847e-22 1.407263758535593127e-21 3.366130352498748235e-21 0.000000000000000000e+00 7.331967271906080159e-22 2.391949465510364080e-21 1.702419785594443253e-21 3.039135564145483000e-20 1.968000169376686586e+02 3.104040490186073571e-20 2.880627383394906186e-20 3.885444748135082533e-21 6.959713331585127741e-25 7.537097272837750242e-21 5.324241094387640373e-23 1.829086872261979354e-22 1.407147669200950706e-21 2.923109116153210613e-21 0.000000000000000000e+00 7.337209333677740651e-22 2.319810644706578951e-21 1.704274255282267498e-21 3.034948548582823905e-20 1.970500063435675315e+02 3.182792680875232021e-20 2.881567372432592823e-20 4.099365677060039509e-21 6.918412066505640008e-25 7.532519734827384295e-21 5.306058651840607274e-23 1.824661064379499239e-22 1.407038545464805766e-21 3.339902319941852154e-21 0.000000000000000000e+00 7.320896811379143342e-22 2.212120999414084425e-21 1.706128567924925555e-21 3.042035221301453156e-20 1.972500063371355168e+02 2.937917665049602112e-20 2.882320037812976435e-20 4.246627280946238904e-21 6.885362887240632225e-25 7.528857543425337058e-21 5.291512145867810661e-23 1.821120268141168792e-22 1.406979652222062806e-21 3.072098339099674733e-21 0.000000000000000000e+00 7.322485698922370346e-22 2.192431275456512178e-21 1.707612080857288274e-21 3.041720970628346817e-20 1.974500063307165476e+02 3.036120735209472806e-20 2.883073273661451905e-20 4.520607273378442948e-21 6.852313707973469980e-25 7.525195354226370112e-21 5.276965697319404200e-23 1.817579471902607242e-22 1.406920909144777640e-21 3.176491756345279352e-21 0.000000000000000000e+00 7.401965927775918873e-22 2.265842073855801232e-21 1.709095593789747665e-21 3.047923706063093791e-20 1.977000168605624424e+02 3.103411869701356059e-20 2.884015659751809494e-20 4.294041744448334069e-21 6.811874710787136617e-25 7.520634409042849476e-21 5.258781951676687912e-23 1.813153290042154330e-22 1.406830871937692388e-21 2.875965400537666683e-21 0.000000000000000000e+00 7.356638941414611173e-22 2.297579860886571305e-21 1.710950063120653833e-21 3.042674456734295701e-20 1.979500063147258402e+02 3.174797145143392897e-20 2.884958856147375982e-20 4.252831829669341859e-21 6.771715114602177805e-25 7.516099280684232333e-21 5.240599830318229434e-23 1.808727481305199848e-22 1.406715856697187901e-21 3.028609849053061854e-21 0.000000000000000000e+00 7.433189011830897910e-22 2.288758918221786170e-21 1.712804376121317064e-21 3.044320146203130182e-20 1.981500063083521752e+02 2.985403695514177951e-20 2.885714085114841724e-20 4.423976854032535138e-21 6.739687907589730345e-25 7.512471031458969718e-21 5.226053586540160121e-23 1.805186685065836377e-22 1.406624006515348964e-21 2.912749306551366183e-21 0.000000000000000000e+00 7.534354605883493845e-22 2.270685688340448142e-21 1.714287889054112741e-21 3.046151424318317488e-20 1.983500063019913568e+02 3.077373551350177704e-20 2.886469882539888556e-20 4.463606273759630367e-21 6.708576797468079141e-25 7.508891182527063856e-21 5.211507402371476342e-23 1.801645888826245329e-22 1.406559210302002855e-21 3.079799102646496171e-21 0.000000000000000000e+00 7.556676623474215063e-22 2.382899350741438812e-21 1.715771401987003586e-21 3.049868730797354011e-20 1.986000167841550592e+02 3.525191270646095455e-20 2.887415467728655661e-20 4.043989392508977766e-21 6.669686278020390219e-25 7.504431297092274044e-21 5.193323993800520891e-23 1.797219707809956993e-22 1.406486829606072706e-21 2.825071262432765888e-21 0.000000000000000000e+00 7.619047386127764161e-22 2.340495314276283789e-21 1.717625870964224004e-21 3.042022409088345093e-20 1.988500062861452307e+02 3.282635974449637527e-20 2.888361860175119566e-20 3.754285281223179392e-21 6.630747405647067596e-25 7.499943468436431273e-21 5.175142206039513927e-23 1.792793898226278179e-22 1.406418204342759330e-21 2.684486916466478806e-21 0.000000000000000000e+00 7.779729361175073985e-22 2.731511121918304966e-21 1.719468094299167014e-21 3.041133836053490117e-20 1.990500062798290912e+02 3.158515934618541274e-20 2.889119643687012876e-20 4.286488437989055584e-21 6.599521600181586857e-25 7.496281337500656379e-21 5.160596234482546866e-23 1.789253101985896259e-22 1.406366121438699956e-21 2.889103912730062897e-21 0.000000000000000000e+00 7.833896066585216918e-22 3.287913395662903629e-21 1.720928368662880146e-21 3.056165214383311731e-20 1.992500062735256279e+02 3.075337410332490968e-20 2.889877993648644522e-20 4.750924926157890328e-21 6.568295794714125227e-25 7.492619208622457770e-21 5.146050324832186341e-23 1.785712305745290054e-22 1.406314161618981469e-21 2.811102195758322684e-21 0.000000000000000000e+00 7.817059722070408053e-22 2.760222108443346737e-21 1.722388643026685813e-21 3.057713486258653881e-20 1.995000167084370730e+02 3.143528679890603750e-20 2.890826766639549888e-20 4.597696602508503410e-21 6.529940342920958800e-25 7.488098005364344600e-21 5.127867266135531099e-23 1.781286125565554733e-22 1.406229532369579020e-21 3.056804784549721588e-21 0.000000000000000000e+00 7.757025741097277762e-22 2.401259863899775537e-21 1.724214062228143197e-21 3.055478586945596160e-20 1.997500062578221787e+02 3.112825464921612551e-20 2.891776343844967881e-20 4.472144112837372267e-21 6.492322867870627011e-25 7.483638532859042988e-21 5.109685825017315730e-23 1.776860315142796767e-22 1.406123601541917018e-21 3.008447783698279754e-21 0.000000000000000000e+00 7.773548498902907093e-22 2.415872372507618174e-21 1.726039328936603034e-21 3.054053073986793113e-20 1.999500062515627974e+02 3.021951706723309373e-20 2.892536672870744084e-20 4.041996486338673449e-21 6.462227630717275628e-25 7.480070807952074236e-21 5.095140136225411316e-23 1.773319518901410034e-22 1.406038989146374531e-21 2.869950320446827438e-21 0.000000000000000000e+00 7.739676881941473114e-22 2.022516137255505577e-21 1.727499603300730317e-21 3.044482700279140302e-20 2.001500062453159501e+02 3.173157280184525818e-20 2.893297566341144068e-20 3.765637686966335078e-21 6.432310179270375480e-25 7.476531418421224130e-21 5.080594511756856354e-23 1.769778722659801368e-22 1.405982618595622059e-21 2.863267747098487568e-21 0.000000000000000000e+00 7.730464749860788000e-22 1.999011938540315124e-21 1.728959877664949382e-21 3.041360836799267987e-20 2.004000166333991615e+02 3.130340653102681857e-20 2.894249515853220963e-20 3.897961060296885706e-21 6.395007042000815628e-25 7.472113248969499553e-21 5.062411816404047926e-23 1.765352543309112354e-22 1.405918527389943914e-21 3.186227502221548124e-21 0.000000000000000000e+00 7.599920428971233842e-22 2.130666915099357893e-21 1.730785296524496648e-21 3.047900803001308952e-20 2.006500062297532168e+02 2.977244341490174572e-20 2.895202266541054746e-20 4.072010637878395885e-21 6.357732419636250301e-25 7.467683783086053995e-21 5.044230735651912967e-23 1.760926732054816973e-22 1.405843053044359386e-21 3.013749802670042277e-21 0.000000000000000000e+00 7.560304580758499358e-22 2.638943472441124655e-21 1.732610563575894267e-21 3.053190737949273275e-20 2.008500062235498262e+02 3.108322677992285433e-20 2.895965132062562526e-20 4.056495887323315057e-21 6.328399087212746923e-25 7.464116076720172309e-21 5.029685340720445416e-23 1.757385935812439063e-22 1.405758987730043789e-21 3.141261039117648022e-21 0.000000000000000000e+00 7.517249676317732767e-22 2.870652118520485334e-21 1.734070837940430434e-21 3.056991039340882984e-20 2.010500062173587708e+02 3.247906049022784679e-20 2.896728560026370325e-20 3.872630435508056615e-21 6.299065754787434386e-25 7.460548372218127382e-21 5.015140012656467372e-23 1.753845139569842746e-22 1.405675043248784304e-21 3.050848304752321094e-21 0.000000000000000000e+00 7.471995994380495080e-22 2.949740412449904374e-21 1.735531070716654681e-21 3.055075940765488919e-20 2.013000165590322581e+02 3.171204735515613833e-20 2.897683674794315846e-20 3.509102354456580537e-21 6.262454745740145624e-25 7.456123646822407016e-21 4.996957694827861455e-23 1.749418961040790430e-22 1.405590134589018713e-21 3.145786510789765780e-21 0.000000000000000000e+00 7.448365614610675463e-22 2.992243240620767459e-21 1.737327970919978780e-21 3.052860977994762261e-20 2.015500062019349343e+02 3.148088167483438857e-20 2.898639587703781831e-20 4.041086766160043788e-21 6.226265768862805419e-25 7.451737300937455137e-21 4.978776988887825501e-23 1.744993148962399217e-22 1.405526929804925680e-21 2.856475929364088666e-21 0.000000000000000000e+00 7.352793350317701358e-22 3.234961192429323693e-21 1.739124722354955292e-21 3.059849622640242589e-20 2.017500061957867672e+02 3.241578160295916013e-20 2.899404980715545499e-20 4.251351827557473667e-21 6.197313388800443799e-25 7.448228081034335689e-21 4.964231899500089000e-23 1.741452352719043531e-22 1.405476502558208936e-21 2.996419464783355545e-21 0.000000000000000000e+00 7.277317640370087806e-22 3.977834570543268994e-21 1.740562183010429384e-21 3.073392297360630297e-20 2.020000165016495259e+02 3.064272833967014676e-20 2.900362549571043753e-20 3.744566229315923736e-21 6.161597689769117374e-25 7.443814991877756425e-21 4.946049885588662029e-23 1.737026174823983984e-22 1.405378888421419610e-21 2.610090431833533261e-21 0.000000000000000000e+00 7.403006418031363766e-22 6.047994996216071817e-21 1.742359082956371002e-21 3.097781197349517430e-20 2.022500061804696259e+02 3.256481321963378691e-20 2.901320914211288156e-20 3.294393058862514475e-21 6.126599134734302046e-25 7.439397256851651705e-21 4.927869481648308074e-23 1.732600362109711218e-22 1.405274854488094393e-21 3.004447694755779888e-21 0.000000000000000000e+00 7.327860282297700290e-22 6.655999167240255577e-21 1.744155834649496982e-21 3.109468271137321177e-20 2.024500061743639492e+02 3.250149174694634929e-20 2.902088266831081341e-20 3.499649605413500545e-21 6.098599135589094985e-25 7.435880303343023949e-21 4.913324638383150178e-23 1.729059565865603215e-22 1.405201689845498732e-21 2.815863494074637322e-21 0.000000000000000000e+00 7.295592953036511083e-22 6.214585048623763414e-21 1.745593295305276515e-21 3.101431772686277927e-20 2.026500061682703517e+02 3.047748862671908999e-20 2.902856178340580698e-20 3.675340761764776627e-21 6.070494368662891919e-25 7.432403896248765215e-21 4.898779866849799665e-23 1.725518769621281508e-22 1.405151813951752903e-21 3.071852639542881508e-21 0.000000000000000000e+00 7.321930085604756132e-22 5.047751830507840354e-21 1.747030755961142565e-21 3.085315353078214852e-20 2.029000164284533980e+02 3.133611692707807018e-20 2.903816892464494949e-20 3.662471612064001780e-21 6.035254827227566739e-25 7.428058212633957656e-21 4.880598257576676600e-23 1.721092592534934568e-22 1.405089639998490882e-21 3.067130513126624734e-21 0.000000000000000000e+00 7.315286215095315146e-22 4.035124194902830775e-21 1.748827655578770303e-21 3.070984095763517107e-20 2.031500061530887535e+02 3.129277919374273253e-20 2.904778399347189590e-20 3.687854776828388458e-21 6.000018180326582185e-25 7.423712888770695743e-21 4.862418256067478391e-23 1.716666779009549541e-22 1.405027663905212126e-21 2.888947887140838805e-21 0.000000000000000000e+00 7.346713778767284759e-22 3.266298193750121628e-21 1.750624407601184412e-21 3.061226272806572140e-20 2.033500061470370497e+02 3.270258398985844918e-20 2.905548263479668474e-20 3.699852556676580530e-21 5.972786666308144513e-25 7.420236512907592335e-21 4.847873740692590595e-23 1.713125982764486097e-22 1.404978219796061431e-21 2.903043745303530027e-21 0.000000000000000000e+00 7.329567705216661094e-22 2.791023091509228764e-21 1.752061868257351764e-21 3.057449871446619859e-20 2.036000163719705540e+02 3.081129497877292413e-20 2.906511416165576211e-20 3.993320394034628677e-21 5.938879029551537198e-25 7.415890870936456273e-21 4.829692457441305816e-23 1.708699806302196411e-22 1.404916585668696492e-21 2.756877956745624916e-21 0.000000000000000000e+00 7.214243749247657713e-22 2.294094067539432656e-21 1.753774227640389316e-21 3.056448343007138351e-20 2.038500061319596739e+02 3.108979362470698452e-20 2.907475359260035176e-20 4.580999486248007280e-21 5.905024176017962303e-25 7.411545587333322923e-21 4.811512780446992111e-23 1.704273992150908838e-22 1.404816074559107382e-21 3.012130540372131515e-21 0.000000000000000000e+00 7.198335335508661053e-22 2.044040967567963237e-21 1.755474909484888918e-21 3.066127225370312542e-20 2.040500061259494373e+02 3.063912399101160463e-20 2.908247170589908794e-20 4.739828314449154768e-21 5.878149176825587266e-25 7.408069220073690128e-21 4.796968529416561578e-23 1.700733195905111415e-22 1.404734498362699504e-21 3.020144077494578705e-21 0.000000000000000000e+00 7.108352684788379662e-22 2.000613812972181994e-21 1.756835510649885102e-21 3.068966620205102275e-20 2.043000163158747000e+02 3.091984865262236672e-20 2.909212755058373512e-20 4.977168107976895830e-21 5.844554057554377661e-25 7.403723586141376626e-21 4.778787582541465303e-23 1.696307020062607004e-22 1.404645722677144094e-21 2.556100457315014027e-21 0.000000000000000000e+00 7.069789645049195371e-22 2.273573777811973749e-21 1.758536331479363644e-21 3.071218578178488476e-20 2.045500061109752323e+02 3.078226429951276504e-20 2.910179127588090115e-20 5.050086327302634099e-21 5.811149190295821504e-25 7.399378314111530965e-21 4.760608240608183504e-23 1.691881205289707673e-22 1.404585046467716136e-21 2.950856860059691725e-21 0.000000000000000000e+00 7.047409467019874530e-22 1.864578968642453901e-21 1.760237013562726331e-21 3.074006314807918599e-20 2.047500061050060083e+02 3.291584618165789223e-20 2.910952943011870006e-20 5.024037892945553642e-21 5.784649191086743310e-25 7.395901962267789248e-21 4.747099819477635777e-23 1.688542540643836205e-22 1.404540675574742525e-21 3.066242899360696792e-21 0.000000000000000000e+00 6.957877695409768740e-22 2.094977519282396615e-21 1.761597614728001625e-21 3.076827342291997831e-20 2.049500060990484656e+02 3.022108841661273317e-20 2.911727390716187672e-20 4.867977548129555572e-21 5.758149191876117688e-25 7.392478601113432166e-21 4.734903946755871077e-23 1.685460060644687658e-22 1.404477181337474815e-21 3.077562391642143701e-21 0.000000000000000000e+00 6.948578609030122861e-22 2.043629823257905814e-21 1.762958215893356665e-21 3.074741376897683146e-20 2.052000162443138436e+02 3.154171772901419602e-20 2.912696266844217396e-20 5.047814335460895408e-21 5.725450218423673909e-25 7.388243395831446121e-21 4.719658576455863959e-23 1.681606804168083907e-22 1.404381932289197934e-21 2.843056797075788035e-21 0.000000000000000000e+00 7.070273080942694434e-22 1.957704745541759727e-21 1.764659036419013363e-21 3.075676848684158222e-20 2.054500060842053131e+02 2.942983017630934801e-20 2.913665926925988770e-20 4.956966554222271154e-21 5.693297679016093199e-25 7.384008552026926338e-21 4.704414544927075350e-23 1.677753860646034469e-22 1.404286849766199035e-21 2.715566700821582224e-21 0.000000000000000000e+00 7.085033832175437469e-22 1.552974083217107154e-21 1.766359718807089012e-21 3.071563822243315302e-20 2.056500060782882713e+02 3.110710364850901939e-20 2.914442307032018817e-20 4.775643408945288340e-21 5.667574602854038442e-25 7.380532232768599716e-21 4.692218897495677276e-23 1.674671380646261499e-22 1.404242939259979382e-21 2.705503266178699496e-21 0.000000000000000000e+00 7.151398306761439151e-22 1.559893305896131637e-21 1.767720319972719776e-21 3.069312370473430483e-20 2.059000161890879212e+02 3.146831956896688779e-20 2.915413596456139033e-20 4.440884758921272240e-21 5.635497925773146953e-25 7.376186654984078945e-21 4.676973813395904631e-23 1.670818124700857533e-22 1.404188193804941001e-21 2.445497240713205787e-21 0.000000000000000000e+00 7.249832938030215276e-22 1.576888145008115192e-21 1.769394479412167502e-21 3.063035210325307544e-20 2.061500060635459022e+02 3.224115961705259906e-20 2.916385667496447363e-20 4.384945260746139238e-21 5.603467973108216589e-25 7.371881171046695759e-21 4.661730066613649546e-23 1.666965180646055012e-22 1.404119191106041827e-21 2.902093664228455870e-21 0.000000000000000000e+00 7.220444504312565091e-22 1.582134651001908367e-21 1.771054168405602962e-21 3.067063259474771869e-20 2.063500060576689066e+02 3.083718024885791526e-20 2.917163974605906861e-20 4.567351020219182705e-21 5.577842973861206085e-25 7.368493161668802167e-21 4.649534650697758176e-23 1.663882700645664907e-22 1.404043591591005724e-21 2.481160407115460891e-21 0.000000000000000000e+00 7.275767214267642306e-22 1.531385967868963177e-21 1.772381973340314170e-21 3.066452581688799516e-20 2.066000161342362276e+02 3.118069033037921627e-20 2.918137670580945162e-20 4.571702905496934575e-21 5.546514907538523892e-25 7.364258008470037525e-21 4.634289860657163223e-23 1.660029445227863243e-22 1.403949230558113895e-21 3.014644288697278262e-21 0.000000000000000000e+00 7.262146297434636937e-22 1.489858469158351152e-21 1.774041796456056385e-21 3.071919039849180716e-20 2.068500060430262693e+02 3.196348422415989958e-20 2.919112145837688095e-20 4.098896898298469679e-21 5.515285398932751636e-25 7.360023203014872526e-21 4.619046406611704644e-23 1.656176500643921343e-22 1.403882280006245102e-21 2.737327474557449579e-21 0.000000000000000000e+00 7.178683282882374363e-22 1.337872489758562749e-21 1.775701485677423397e-21 3.062750778401024498e-20 2.070500060371890072e+02 3.136334537790732912e-20 2.919892374559060147e-20 3.877858787457852996e-21 5.490350029907348452e-25 7.356635223730151908e-21 4.606851228667799695e-23 1.653094020642919042e-22 1.403839087869989841e-21 2.788536196471789760e-21 0.000000000000000000e+00 7.134131868871925848e-22 1.503641044999757755e-21 1.777029290612398292e-21 3.061762391939929387e-20 2.073000160797549825e+02 3.243840023374216758e-20 2.920868470348335671e-20 4.288469309791590244e-21 5.459733415463883265e-25 7.352400085876507941e-21 4.591606740838947685e-23 1.649240765749159577e-22 1.403785237996536993e-21 2.882652441018408842e-21 0.000000000000000000e+00 7.244983959794009673e-22 1.558161963225310299e-21 1.778689113502404591e-21 3.069237896233735024e-20 2.075500060226450785e+02 3.198667722126201331e-20 2.921845343087948138e-20 4.824360145360214254e-21 5.429119262457649652e-25 7.348232486380675186e-21 4.576363587818690990e-23 1.645387820639653918e-22 1.403692124819780086e-21 2.662300598850910074e-21 0.000000000000000000e+00 7.225904935888458150e-22 1.582263683932978984e-21 1.780348802950162786e-21 3.076152943696795016e-20 2.078000160410645094e+02 3.389431817770646010e-20 2.922823148910517580e-20 5.300396971171264178e-21 5.398870812066873926e-25 7.344064574127966018e-21 4.561119321016450734e-23 1.641534566118051028e-22 1.403599162319221420e-21 2.958082430688005971e-21 0.000000000000000000e+00 7.393403916369376242e-22 1.552339216076755936e-21 1.782008625679859492e-21 3.087394231071090300e-20 2.080500060081710387e+02 3.286244718357898231e-20 2.923801730020086744e-20 4.531933362682109000e-21 5.369023525085064133e-25 7.339864760736551929e-21 4.545876388261098972e-23 1.637681620635312042e-22 1.403525295598737723e-21 2.936681973787925453e-21 0.000000000000000000e+00 7.388265910398359887e-22 1.861358686032830299e-21 1.783668315288391084e-21 3.077480389822394610e-20 2.082500060024008803e+02 3.175725285940483683e-20 2.924585240409577909e-20 4.281687638157410618e-21 5.345144737895196994e-25 7.336476822980971666e-21 4.533681633993882017e-23 1.634599140633275305e-22 1.403482719227766028e-21 2.829048147836548314e-21 0.000000000000000000e+00 7.478042569203679531e-22 2.255981688390858533e-21 1.784981820868453373e-21 3.076220897066677105e-20 2.085000159872096219e+02 3.158364253919656097e-20 2.925565434517882881e-20 4.393170370215762604e-21 5.315296552911619904e-25 7.332241722106836223e-21 4.518437684102440800e-23 1.630745886629693497e-22 1.403429641729971650e-21 2.741835188409415828e-21 0.000000000000000000e+00 7.683893247622683213e-22 2.148271879580923062e-21 1.786613680844909201e-21 3.077122712205192714e-20 2.087500059880238723e+02 3.122005507673294168e-20 2.926546401587248000e-20 4.397193691789642811e-21 5.285451592814410508e-25 7.328092465406427064e-21 4.503195067315580067e-23 1.626892940627437729e-22 1.403345176733569395e-21 2.792630064732181506e-21 0.000000000000000000e+00 7.849600292522383742e-22 2.000009868014785912e-21 1.788245410382251837e-21 3.077522242490333904e-20 2.089500059822923106e+02 3.126138971041872392e-20 2.927331818989361859e-20 4.114664522857488797e-21 5.261574670421746914e-25 7.324790025723523859e-21 4.491000569799277333e-23 1.623810460624806192e-22 1.403271407598375927e-21 2.774016464298284242e-21 0.000000000000000000e+00 8.048119960355142382e-22 1.868669604013110683e-21 1.789550846187896558e-21 3.073345139013074892e-20 2.092000159337151501e+02 3.107507885780947711e-20 2.928314394670355066e-20 4.382497813480748202e-21 5.232489064642699001e-25 7.320653280398775411e-21 4.475756945839967727e-23 1.619957207135781285e-22 1.403182492923818377e-21 2.737098381323398575e-21 0.000000000000000000e+00 8.032608621065030678e-22 2.239908054069322859e-21 1.791182705946436798e-21 3.080033112345595701e-20 2.094500059680113679e+02 2.948161573806234185e-20 2.929297740989688760e-20 4.340082059757876000e-21 5.203550824309014515e-25 7.316418548526205956e-21 4.460514654192532822e-23 1.616104260617487964e-22 1.403130028659591592e-21 2.910812005478722222e-21 0.000000000000000000e+00 8.074216951114498385e-22 2.535014524135378568e-21 1.792814435702322078e-21 3.084164292737663031e-20 2.096500059623180903e+02 3.098305058030425233e-20 2.930085060038835646e-20 4.461516479918463422e-21 5.180399320657116631e-25 7.313030629658831538e-21 4.448320420842855626e-23 1.613021780614266329e-22 1.403088171710029755e-21 2.685870847690994380e-21 0.000000000000000000e+00 8.115286953442448154e-22 2.081329644678745895e-21 1.794119871508216944e-21 3.081144797422307481e-20 2.099000158805774561e+02 3.095547095773216505e-20 2.931070010588383240e-20 4.636798892739710127e-21 5.151913342091806611e-25 7.308838336254123791e-21 4.433077132185975095e-23 1.609168527636370345e-22 1.403035993640422107e-21 2.795490491320480834e-21 0.000000000000000000e+00 8.155401792518483207e-22 2.054074622360841659e-21 1.795751731050293191e-21 3.085378991169099667e-20 2.101500059481322182e+02 3.227554056746888776e-20 2.932055729456811296e-20 4.463963863077551950e-21 5.123429625303748015e-25 7.304710500693973708e-21 4.417835175203512785e-23 1.605315580605482965e-22 1.402983981041468626e-21 2.851585687081381875e-21 0.000000000000000000e+00 8.129168315604418191e-22 2.164407674025239411e-21 1.797383461023263125e-21 3.084938504972918510e-20 2.104000158428384282e+02 2.995307319944321019e-20 2.933042372241466737e-20 4.194792348900864747e-21 5.095052759534601854e-25 7.300582339935855052e-21 4.402592131987289540e-23 1.601462327990597504e-22 1.402932125675770210e-21 2.961369376935696551e-21 0.000000000000000000e+00 8.072316493971071458e-22 2.085387036955357018e-21 1.799015320411603518e-21 3.082484341784820378e-20 2.106500059340136772e+02 3.152057851103938990e-20 2.934029781690258677e-20 3.978462115257841027e-21 5.066872058347573378e-25 7.296454508364897205e-21 4.387350420088530963e-23 1.597609380595661639e-22 1.402848166238720361e-21 2.636953684855574530e-21 0.000000000000000000e+00 7.973266556377899843e-22 1.746429364199072839e-21 1.800640875831960938e-21 3.075380455285798480e-20 2.108500059283850305e+02 3.094309284083980437e-20 2.934820348243302929e-20 3.866211827681919209e-21 5.044326604436619690e-25 7.293152113889994577e-21 4.375156657686166877e-23 1.594526900591443890e-22 1.402779339160328910e-21 2.615406302409822537e-21 0.000000000000000000e+00 7.974604538110645057e-22 2.018018406124977319e-21 1.801935617807316518e-21 3.076110372447926168e-20 2.111000157903041838e+02 3.223274281721895312e-20 2.935809354424772432e-20 3.913060014264157958e-21 5.016380066893559176e-25 7.289034297912566370e-21 4.359913966697025760e-23 1.590673648481885818e-22 1.402699733176602607e-21 2.800093001258613695e-21 0.000000000000000000e+00 7.878536220975366318e-22 1.762359267180850895e-21 1.803554109165264197e-21 3.077587428629230441e-20 2.113500059143599685e+02 3.088004077397631235e-20 2.936799124956594486e-20 4.124288180424191068e-21 4.988653889498281230e-25 7.284970984136281783e-21 4.344672606668254697e-23 1.586820700580182113e-22 1.402653401431087698e-21 2.780152507978276644e-21 0.000000000000000000e+00 7.819744582093038227e-22 2.179201243333414637e-21 1.805172472746006958e-21 3.083670325174966703e-20 2.115500059087685543e+02 3.090854692081712206e-20 2.937591578629433352e-20 4.335009317399719961e-21 4.966472071936600415e-25 7.281720206275132076e-21 4.332479130054688544e-23 1.583738220575390488e-22 1.402616429438105049e-21 2.555071987635024525e-21 0.000000000000000000e+00 7.753362606527473582e-22 1.793845833327049309e-21 1.806467214721603655e-21 3.082799412025385915e-20 2.118000157381171391e+02 3.186634729468754395e-20 2.938582941528337887e-20 4.492184897372967058e-21 4.939329652023255562e-25 7.277630782562431723e-21 4.317236801698645687e-23 1.579884968967823047e-22 1.402554545934864187e-21 2.924105751555019334e-21 0.000000000000000000e+00 7.680769892168653539e-22 2.024509610699473548e-21 1.808085705868698492e-21 3.090586900398768449e-20 2.120500058948360333e+02 3.219639495001314545e-20 2.939575066467166358e-20 4.171774987406274568e-21 4.912465038166896028e-25 7.273502999473141584e-21 4.301995804118330347e-23 1.576032020562702366e-22 1.402469125855368380e-21 2.631623234810772738e-21 0.000000000000000000e+00 7.640854062965170519e-22 1.994104319200088295e-21 1.809704069660892938e-21 3.084107759399041897e-20 2.123000157010513931e+02 3.135735423750971099e-20 2.940568108651406350e-20 4.005903060501600482e-21 4.885598315705418912e-25 7.269374893969582893e-21 4.286753741387286569e-23 1.572178769311673412e-22 1.402383828301141952e-21 2.606855985808445043e-21 0.000000000000000000e+00 7.692547743936245055e-22 2.065304533353085292e-21 1.811322560658230172e-21 3.083037803597379313e-20 2.125500058809691097e+02 3.126154040180051484e-20 2.941561911227344384e-20 4.578236552648575883e-21 4.858781187314244397e-25 7.265338230395683700e-21 4.271513009409593597e-23 1.568325820549003085e-22 1.402333393188481943e-21 2.686928206420491017e-21 0.000000000000000000e+00 7.643529288916010068e-22 2.202659039443330004e-21 1.812940924600606905e-21 3.093475840768376316e-20 2.127500058754405927e+02 3.067298397491416663e-20 2.942357587546808797e-20 5.100626164213609240e-21 4.837326642452756859e-25 7.262118709695174419e-21 4.259320042824710888e-23 1.565243340543242147e-22 1.402296924719138296e-21 2.610012435804925483e-21 0.000000000000000000e+00 7.722269259869015761e-22 2.111566005692456338e-21 1.814235666576610981e-21 3.101053022858027798e-20 2.130000156494517114e+02 3.150164264189028359e-20 2.943352975019853032e-20 5.192900156016724009e-21 4.810619260505064829e-25 7.258089467623590316e-21 4.244078361548120877e-23 1.561390089788557923e-22 1.402246791997383026e-21 2.730881847620317003e-21 0.000000000000000000e+00 7.733904144382899585e-22 1.830844177138092359e-21 1.815851496830163690e-21 3.102702661667475512e-20 2.132500058616646470e+02 3.271467362448196812e-20 2.944349120580013092e-20 4.622354218628247296e-21 4.784500880124608370e-25 7.254026194316522575e-21 4.228838011152661433e-23 1.557537140528140735e-22 1.402162612259184181e-21 2.471749115443245976e-21 0.000000000000000000e+00 7.754079295987803869e-22 2.045932199525813359e-21 1.817443428034894274e-21 3.093700174563040276e-20 2.135000156128019455e+02 3.055799832947482126e-20 2.945346179185007485e-20 4.186643523036879045e-21 4.758380458363994131e-25 7.249962605395605795e-21 4.213596609411100700e-23 1.553683890125996907e-22 1.402078555324323452e-21 2.845347989994669198e-21 0.000000000000000000e+00 7.753887314736020527e-22 1.905249149738203641e-21 1.819035483662989415e-21 3.090670137450330747e-20 2.137500058479531333e+02 3.095651810980994691e-20 2.946343994233100569e-20 4.812669849509222866e-21 4.732405366151723937e-25 7.245921211038913928e-21 4.198356538759500045e-23 1.549830940512046266e-22 1.402016391418888285e-21 2.710251521093172253e-21 0.000000000000000000e+00 7.739142694626987454e-22 1.997436174983621332e-21 1.820627415013790124e-21 3.099999569578634049e-20 2.140000155763234488e+02 3.146612621219493506e-20 2.947342720578716607e-20 4.826535128635310578e-21 4.706583465848401853e-25 7.241896689517710871e-21 4.183115422637700568e-23 1.545977690460796435e-22 1.401971447063982321e-21 2.578103661051416927e-21 0.000000000000000000e+00 7.799582011000632008e-22 3.050390973202879094e-21 1.822219470496905998e-21 3.108528457181370358e-20 2.142500058343056537e+02 3.244846244893444241e-20 2.948342201725196291e-20 4.878059859999124068e-21 4.680763576516509186e-25 7.237872483405564297e-21 4.167875637916080007e-23 1.542124740494965087e-22 1.401926637214978330e-21 2.388996706413992255e-21 0.000000000000000000e+00 7.777772800270705383e-22 5.677204104814601339e-21 1.823811401993093729e-21 3.145337079377364002e-20 2.144500058288644482e+02 3.112511096235284930e-20 2.949142476764592111e-20 4.574184227730880882e-21 4.660599417113573104e-25 7.234653015728092616e-21 4.156758556677131961e-23 1.539261272345495238e-22 1.401859800638510093e-21 2.705641691651572829e-21 0.000000000000000000e+00 7.676556499652519321e-22 3.110308023081154609e-21 1.825084996784928771e-21 3.107913892101995530e-20 2.147000155255389870e+02 3.234578900954151871e-20 2.950143668505750217e-20 4.397749179544451939e-21 4.635598447446117700e-25 7.230628535402272273e-21 4.143966221865065188e-23 1.535906782597645767e-22 1.401776368215867270e-21 2.473383903439857370e-21 0.000000000000000000e+00 7.656736256287922357e-22 2.275237846342372363e-21 1.826677052066206435e-21 3.097038227458286369e-20 2.149500058153058148e+02 2.978923120273395655e-20 2.951145611930434678e-20 4.475519618818019712e-21 4.610599418469432511e-25 7.226609994716154852e-21 4.131175012643898308e-23 1.532552553240788641e-22 1.401702398162095991e-21 2.519517111957853044e-21 0.000000000000000000e+00 7.624089945555364101e-22 2.222307888727871898e-21 1.828268983764798119e-21 3.099000851237509666e-20 2.152000154894666082e+02 3.125515088153138090e-20 2.952148461666736874e-20 4.697269084967777056e-21 4.585664127318866928e-25 7.222608943445698040e-21 4.118382945421494272e-23 1.529198063795016298e-22 1.401658084016141694e-21 2.854051757399972962e-21 0.000000000000000000e+00 7.573938109385897344e-22 2.245784125550267539e-21 1.829861038902709106e-21 3.106202491028973822e-20 2.154500058018100788e+02 3.164063873562891701e-20 2.953152061450218908e-20 4.447303477551864915e-21 4.560739720058354038e-25 7.218608202189352656e-21 4.105592003948560791e-23 1.525843834135238509e-22 1.401613905284071675e-21 2.536171744769859095e-21 0.000000000000000000e+00 7.660045467115764610e-22 2.351927236049969351e-21 1.831452297371968171e-21 3.101437926283265305e-20 2.157000154535615195e+02 3.066653222238898760e-20 2.954156565805262641e-20 4.104477967430461840e-21 4.535945558919044395e-25 7.214656392632035770e-21 4.092800209314521059e-23 1.522489344990142104e-22 1.401545365069943322e-21 2.667275860645149773e-21 0.000000000000000000e+00 7.617177846599122148e-22 2.302961652897037309e-21 1.833018598204632763e-21 3.098305111330608064e-20 2.159500057883768704e+02 3.175350137354502886e-20 2.955161818572959699e-20 3.842135488107403929e-21 4.511681791128143424e-25 7.210732597624684792e-21 4.080009540661436105e-23 1.519135115028849075e-22 1.401463187819877957e-21 2.578051782274220560e-21 0.000000000000000000e+00 7.665600254391503908e-22 2.161776658762810805e-21 1.834584778017437323e-21 3.094053318264714127e-20 2.161500057830209869e+02 3.128490069997421086e-20 2.955966646040040753e-20 3.859864645344670891e-21 4.492270026942096763e-25 7.207593441649872490e-21 4.069776710364808295e-23 1.516451627386059989e-22 1.401397536822285389e-21 2.563504931429021542e-21 0.000000000000000000e+00 7.827292352080827745e-22 2.413839892658038513e-21 1.835837770275734220e-21 3.096758875514092678e-20 2.164000154035730930e+02 3.195906240066796715e-20 2.956973461195848944e-20 4.250444147221233421e-21 4.468086758363301571e-25 7.203585042863184474e-21 4.056985305993021648e-23 1.513097138659578751e-22 1.401347731878948970e-21 2.643968727785342031e-21 0.000000000000000000e+00 7.788613094590036041e-22 2.625335638112082785e-21 1.837404070912936106e-21 3.105126520213405005e-20 2.166500057696745216e+02 3.256481471419134235e-20 2.957981022479059767e-20 4.584265918948877476e-21 4.444117093848870116e-25 7.199560907955623042e-21 4.044195028052362387e-23 1.509742908278506815e-22 1.401304183732626398e-21 2.676821552570977317e-21 0.000000000000000000e+00 7.839333981686221050e-22 2.319484257067652258e-21 1.838970250921746920e-21 3.108607679682239381e-20 2.169000153680646292e+02 3.213746520565025073e-20 2.958989484165031136e-20 4.708731725072249722e-21 4.420145585297346054e-25 7.195553800364411982e-21 4.031403908787648075e-23 1.506388419849382860e-22 1.401253205689944950e-21 2.747376412685909572e-21 0.000000000000000000e+00 7.843443663376189892e-22 2.500628192936977858e-21 1.840536551420104680e-21 3.113361275392358041e-20 2.171500057563895325e+02 3.118248637529677931e-20 2.959998690348302846e-20 4.612581908929090261e-21 4.396422987633939262e-25 7.191591558347480963e-21 4.018613916368384704e-23 1.503034189170128679e-22 1.401175400379777163e-21 2.700216961191346144e-21 0.000000000000000000e+00 7.944744419894347394e-22 2.431077493569844793e-21 1.842102731568144430e-21 3.111860321358187644e-20 2.174000153327195051e+02 3.230206827999815779e-20 2.961008795200423383e-20 4.752193416106932022e-21 4.372892674567588750e-25 7.187629009674675037e-21 4.005823087654497032e-23 1.499679701036995377e-22 1.401097697096307529e-21 2.617402046908006619e-21 0.000000000000000000e+00 7.997490826830553442e-22 2.623044234543501279e-21 1.843669031928296780e-21 3.115701686937078609e-20 2.176500057431655648e+02 3.162389680826129563e-20 2.962019642921603503e-20 5.066815362945655682e-21 4.349364165349135917e-25 7.183733340787039077e-21 3.993033386280042994e-23 1.496325470060931928e-22 1.401046132834846291e-21 2.920952724246795105e-21 0.000000000000000000e+00 8.046033429041587706e-22 2.372812962212966665e-21 1.845235212214924869e-21 3.122236505494078620e-20 2.179000152975365552e+02 3.231613014693617591e-20 2.963031387579555178e-20 4.744985486784394407e-21 4.326363816225648811e-25 7.179868735630321316e-21 3.980242853700951586e-23 1.492970982222431819e-22 1.401006919712489715e-21 2.771504790786412001e-21 0.000000000000000000e+00 8.183530185522961966e-22 3.021610093679500992e-21 1.846801512437504507e-21 3.122337811632244091e-20 2.181500057300022206e+02 3.256864241076408236e-20 2.964043873480202857e-20 4.637877160391724672e-21 4.303466141831692812e-25 7.176002055620504805e-21 3.967453449037095612e-23 1.489616750950921736e-22 1.400966287960730787e-21 2.651281254904948612e-21 0.000000000000000000e+00 8.153868844318790223e-22 2.675647714608215228e-21 1.848358183022902571e-21 3.117397400962203853e-20 2.184000152625147564e+02 3.169232412512213433e-20 2.965057254587393713e-20 4.951215635983814994e-21 4.280563305322186404e-25 7.172078018386759994e-21 3.954663218321515174e-23 1.486262263405706292e-22 1.400889019650270360e-21 2.421965415649982907e-21 0.000000000000000000e+00 8.133355873500723158e-22 2.933846571436536933e-21 1.849913123970796542e-21 3.123544302738599255e-20 2.186500057168991020e+02 3.145727493360875053e-20 2.966071375312802600e-20 4.558577633320991000e-21 4.257623004802211524e-25 7.168154270162705935e-21 3.941874116181049206e-23 1.482908031840103509e-22 1.400811865308648598e-21 2.675584396221084960e-21 0.000000000000000000e+00 8.033854366426489300e-22 2.511600874733865432e-21 1.851467946261763710e-21 3.116804576194505605e-20 2.189000152276528866e+02 3.239552174666019788e-20 2.967086389516386011e-20 3.808249306857743897e-21 4.234680955580098816e-25 7.164239712834564948e-21 3.929084193207156789e-23 1.479553544586834547e-22 1.400751657022016220e-21 2.593969746156478199e-21 0.000000000000000000e+00 8.028495526892859284e-22 3.043776610466587732e-21 1.853022887074328376e-21 3.111665653625559276e-20 2.191500057038557543e+02 3.178023261901360043e-20 2.968102141715608327e-20 4.171749138923497382e-21 4.212016885397153203e-25 7.160337532883095360e-21 3.916295399554669642e-23 1.476199312728483360e-22 1.400712995078928041e-21 2.475311103030923243e-21 0.000000000000000000e+00 8.029163250453915597e-22 2.588262494938611103e-21 1.854577709500996493e-21 3.112125768966875156e-20 2.194000151929499509e+02 3.270472460442707313e-20 2.969118785666511287e-20 4.770166151679299285e-21 4.189842130712276723e-25 7.156435066201656792e-21 3.903505790354984117e-23 1.472844825765830690e-22 1.400674440425678176e-21 2.244491971056968015e-21 0.000000000000000000e+00 7.919312613721972563e-22 2.586698433971677929e-21 1.856132650178848754e-21 3.119810773690573530e-20 2.196500056908718079e+02 3.188934781655798690e-20 2.970136165992382502e-20 5.005371199356469840e-21 4.167669060461816244e-25 7.152563200861101042e-21 3.890717311311859097e-23 1.469490593616066225e-22 1.400635998932094093e-21 2.253015172919975349e-21 0.000000000000000000e+00 7.952300308876910926e-22 2.915937065293901076e-21 1.857687472740598663e-21 3.127348453075199157e-20 2.199000151584048126e+02 3.131716163208374101e-20 2.971154436345325485e-20 5.157441417224351619e-21 4.145668238307763133e-25 7.148698628652580384e-21 3.877928022078345740e-23 1.466136106942709298e-22 1.400597664769940699e-21 2.662588286959342284e-21 0.000000000000000000e+00 7.854603763564780195e-22 2.429101257232165703e-21 1.859242413284350529e-21 3.129740045992019420e-20 2.201500056779468082e+02 2.984422811680052799e-20 2.972173441454491401e-20 4.928705842706380519e-21 4.123785010220318544e-25 7.144840419873991102e-21 3.865139863927943397e-23 1.462781874502857983e-22 1.400553410684535272e-21 2.251175103323502774e-21 0.000000000000000000e+00 7.887037926914170011e-22 2.474827268441607186e-21 1.860797235980567587e-21 3.124074267944982696e-20 2.203500056727932019e+02 3.134168081510367621e-20 2.972989260474429249e-20 4.784078579000307458e-21 4.106277764294633501e-25 7.141779190155273665e-21 3.854909067272321619e-23 1.460098386857354915e-22 1.400492750215498591e-21 2.361926866552833257e-21 0.000000000000000000e+00 7.762462304931734171e-22 2.586044303108592577e-21 1.862041141276656870e-21 3.124226618286141752e-20 2.206000151103047244e+02 3.129865115140935917e-20 2.974009802177437062e-20 4.609756116024895529e-21 4.084775856322635098e-25 7.137952511794950402e-21 3.842120236708625956e-23 1.456743900586809340e-22 1.400417019180025397e-21 2.557670670720711982e-21 0.000000000000000000e+00 7.739213121706659343e-22 2.553220567042321547e-21 1.863583031422464585e-21 3.123763793090093785e-20 2.208500056599501420e+02 3.120624787692366403e-20 2.975031076373670633e-20 4.168378596663128868e-21 4.063490946667110767e-25 7.134114003380121918e-21 3.829332538683822881e-23 1.453389667743047351e-22 1.400353468316145294e-21 2.503483914044152928e-21 0.000000000000000000e+00 7.648930833195779388e-22 2.355549631255825458e-21 1.865113350846351176e-21 3.116432717204451064e-20 2.211000150761339853e+02 3.320682154851307558e-20 2.976053236465678092e-20 4.167103484025747089e-21 4.042204430660600427e-25 7.130249450177484434e-21 3.816544043629621385e-23 1.450035181758664590e-22 1.400315660792464359e-21 2.486791207873174615e-21 0.000000000000000000e+00 7.553441502738685638e-22 2.367687310579144587e-21 1.866643785761924284e-21 3.117246925655731324e-20 2.214000150557056088e+02 3.190970791738888388e-20 2.977280848744165220e-20 4.404744159920915142e-21 4.016642195252921645e-25 7.125612179827205562e-21 3.801198652801492962e-23 1.446009950460784024e-22 1.400270439080562892e-21 2.417376491394946373e-21 0.000000000000000000e+00 7.611579627733978649e-22 2.342791493188815415e-21 1.868480238366053750e-21 3.120868978396060039e-20 2.216500056395217086e+02 3.191460952301132087e-20 2.978304708181489482e-20 4.440720006877762441e-21 3.995338649849463531e-25 7.121798683451251845e-21 3.788411496731442549e-23 1.442655717158538802e-22 1.400200188928691760e-21 2.350646829997553197e-21 0.000000000000000000e+00 7.626238550448469573e-22 2.606371370589807462e-21 1.870010557999116646e-21 3.123859727175450074e-20 2.219000150217810869e+02 3.225745398080354180e-20 2.979329450766545602e-20 4.560608153335220923e-21 3.974214758771698345e-25 7.117991819439655450e-21 3.775623552660678417e-23 1.439301231629335666e-22 1.400125586503879986e-21 2.303887009287139651e-21 0.000000000000000000e+00 7.439663442987435970e-22 2.713321715583479505e-21 1.871540992707021092e-21 3.127001769767037954e-20 2.221500056268286869e+02 3.141803154911594255e-20 2.980354921652272991e-20 4.282664256579896097e-21 3.953558392206050127e-25 7.114181286941324302e-21 3.762836744347792358e-23 1.435946998042218085e-22 1.400058528203314239e-21 2.395855895148308006e-21 0.000000000000000000e+00 7.532633635911253166e-22 2.409773387328694216e-21 1.873071312470052661e-21 3.122193890320421409e-20 2.224000149880091044e+02 3.238103951335603348e-20 2.981381273970730744e-20 4.459578397096210819e-21 3.932900475847941798e-25 7.110354640457368475e-21 3.750049153787373438e-23 1.432592512795840536e-22 1.400021291740100287e-21 2.273796101236267860e-21 0.000000000000000000e+00 7.520256622610195972e-22 2.772887367377068139e-21 1.874601747048922057e-21 3.127665470142378793e-20 2.226500056141926223e+02 3.063514006740622123e-20 2.982408352980889140e-20 4.428029339977164328e-21 3.912381256809226336e-25 7.106528286635826645e-21 3.737262700410329318e-23 1.429238278925133298e-22 1.399984168421000608e-21 2.023182889966094670e-21 0.000000000000000000e+00 7.583963843562431063e-22 2.943158269424255060e-21 1.876132066941337375e-21 3.127968050491787172e-20 2.229000149543886096e+02 2.977185352745056472e-20 2.983436311710730621e-20 4.453179082732304365e-21 3.892009067145255479e-25 7.102733631865730929e-21 3.724475470627717109e-23 1.425883793960312976e-22 1.399926346702438989e-21 2.208892267023946030e-21 0.000000000000000000e+00 7.504880035228002241e-22 3.074941294529011007e-21 1.877662501391750629e-21 3.131730642730273002e-20 2.231500056016132021e+02 3.243947901029908869e-20 2.984464995525290041e-20 4.681177983441219275e-21 3.871638400691411192e-25 7.098964383020190735e-21 3.711689379563001175e-23 1.422529559807288201e-22 1.399853956763126938e-21 2.600487085812225471e-21 0.000000000000000000e+00 7.607452687126831754e-22 2.637693386329314854e-21 1.879180724563460779e-21 3.135000911381484426e-20 2.234000149209186361e+02 3.163652133073205718e-20 2.985494557348458143e-20 4.576158712540430951e-21 3.851479945773163174e-25 7.095194860309409096e-21 3.698902518026945300e-23 1.419175075122765918e-22 1.399783572902799986e-21 2.274994155081217633e-21 0.000000000000000000e+00 7.503679548667811738e-22 2.990602875324231968e-21 1.880687471350903237e-21 3.134965770508852099e-20 2.236500055890900569e+02 3.188902601406454828e-20 2.986524842651357223e-20 4.686409554599357316e-21 3.831423551595296651e-25 7.091425623179061517e-21 3.686116796855721466e-23 1.415820840688688201e-22 1.399745977346782156e-21 2.384393973050131120e-21 0.000000000000000000e+00 7.587604272769950176e-22 2.742054792695566248e-21 1.882194105732391282e-21 3.136059756737011034e-20 2.239000148875981324e+02 3.159389679706459757e-20 2.987556004253769475e-20 4.394405532841371089e-21 3.811365662732135083e-25 7.087656106612524528e-21 3.673330311243264446e-23 1.412466356283212995e-22 1.399712925270530514e-21 2.161218964346792463e-21 0.000000000000000000e+00 7.499288771585282446e-22 3.020202211810005058e-21 1.883700852394493317e-21 3.133653561464945808e-20 2.241500055766227320e+02 3.286488645592341813e-20 2.988587887732935334e-20 4.435387236637428898e-21 3.791548130078722411e-25 7.083886872095722564e-21 3.660544967758521880e-23 1.409112121569339411e-22 1.399672534023128072e-21 2.507047556217629602e-21 0.000000000000000000e+00 7.541640344015409513e-22 2.817526769267662405e-21 1.885207486901658447e-21 3.135835875655841153e-20 2.244000148544261322e+02 3.187904893083371185e-20 2.989620645804509181e-20 4.796564553127699020e-21 3.771761681521138899e-25 7.080117358774212022e-21 3.647758865962288962e-23 1.405757637441667845e-22 1.399602505534307549e-21 2.249484492775810756e-21 0.000000000000000000e+00 7.479738129517111033e-22 2.744083746745202737e-21 1.886714233438978654e-21 3.139438747451354344e-20 2.246500055642109714e+02 3.184635986064977713e-20 2.990654197620568810e-20 4.712143687640568858e-21 3.752022671009371762e-25 7.076348129184778441e-21 3.636427160951020770e-23 1.402705017523354697e-22 1.399532570527937286e-21 2.214166479492617506e-21 0.000000000000000000e+00 7.252564441241137154e-22 2.503782386309276809e-21 1.888220868071260769e-21 3.136754338606805923e-20 2.249000148214016122e+02 3.196637144880376948e-20 2.991688654104566680e-20 4.655490689218911209e-21 3.732810692034271273e-25 7.072607469688293869e-21 3.625733529592425998e-23 1.399784733875846150e-22 1.399482042269971775e-21 2.204916870952874228e-21 0.000000000000000000e+00 7.393526539239113876e-22 2.581005884788762302e-21 1.889727614484352476e-21 3.137412774197522460e-20 2.251500055518542638e+02 2.991432084799324945e-20 2.992723828650381354e-20 4.066149332489145210e-21 3.713600136747656437e-25 7.068893687299459218e-21 3.615040887973383256e-23 1.396864666633644602e-22 1.399449440394035954e-21 2.292175753809541054e-21 0.000000000000000000e+00 7.311438853307943488e-22 2.571642828097025014e-21 1.891234249241194486e-21 3.130655606637364812e-20 2.254000147885236061e+02 3.181030092678053014e-20 2.993759873781398018e-20 3.687162783072107510e-21 3.694455781646444123e-25 7.065179631344970554e-21 3.604347653870801550e-23 1.393944383225839336e-22 1.399416926149608323e-21 2.258464763495396558e-21 0.000000000000000000e+00 7.252737225032344944e-22 2.504984129333637903e-21 1.892740995530609141e-21 3.126075731063797177e-20 2.257000147688667653e+02 3.150870478912920990e-20 2.995004128762387163e-20 3.970571654096219426e-21 3.671740290177081242e-25 7.060704822236476227e-21 3.591516513133072846e-23 1.390440172835017856e-22 1.399340867809271043e-21 2.409095663969621761e-21 0.000000000000000000e+00 7.424095765806066168e-22 2.448457930402955820e-21 1.894545416606755435e-21 3.131360575827226224e-20 2.259500055321973093e+02 3.210123620866414731e-20 2.996041841009089493e-20 4.023145320285297165e-21 3.652811412097292336e-25 7.056972936734357545e-21 3.580824513359934657e-23 1.387520105208779247e-22 1.399271394376855697e-21 2.478273069982838520e-21 0.000000000000000000e+00 7.449880391464563519e-22 2.804778817183931705e-21 1.896042313164144796e-21 3.136479454387592169e-20 2.262000147362211635e+02 3.149181237383248507e-20 2.997080421121846147e-20 4.403082839922708210e-21 3.634041716873637668e-25 7.053246572821429938e-21 3.570131929714520635e-23 1.384599822182296356e-22 1.399213897911955128e-21 2.469276419645971452e-21 0.000000000000000000e+00 7.477720734433853315e-22 2.455100297558006448e-21 1.897539320140854969e-21 3.139502250751651714e-20 2.264500055199822555e+02 3.084326491504070360e-20 2.998119715151904431e-20 4.447321534317960055e-21 3.615380433015414485e-25 7.049532796714674830e-21 3.559440340539929953e-23 1.381679754317414526e-22 1.399181762009355307e-21 2.443871184102260212e-21 0.000000000000000000e+00 7.624219283266747264e-22 2.453043815864865585e-21 1.899036216820578497e-21 3.140863555268333286e-20 2.267000147037195745e+02 3.273327964732325189e-20 2.999159875351202943e-20 4.135349782988865138e-21 3.596717775637839809e-25 7.045818748632247267e-21 3.548748172978694142e-23 1.378759471527892488e-22 1.399149713825156971e-21 2.432771299939594405e-21 0.000000000000000000e+00 7.772735645095503474e-22 2.491192865632806415e-21 1.900533223675816658e-21 3.137768575703285304e-20 2.269500055078210323e+02 3.192156760737532834e-20 3.000200747877470645e-20 3.872855646791788439e-21 3.578259876438637501e-25 7.042127047336155978e-21 3.538057001878597556e-23 1.375839403425421151e-22 1.399095787022320621e-21 2.585766130130477444e-21 0.000000000000000000e+00 7.928798797469675224e-22 2.423394790025908582e-21 1.902030120477334190e-21 3.136070906586468160e-20 2.272000146713610604e+02 3.110539232473643156e-20 3.001242484878216799e-20 3.975984401305784064e-21 3.559864836011411047e-25 7.038449784905293876e-21 3.527365257960408267e-23 1.372919120871817537e-22 1.399027299270690215e-21 2.403555899244220194e-21 0.000000000000000000e+00 7.962649644845722011e-22 2.346692378415765614e-21 1.903527127211634858e-21 3.136260102328539104e-20 2.274500054957132988e+02 3.190482965354019405e-20 3.002284932617676098e-20 4.218023447805585409e-21 3.541471144935127950e-25 7.034772793519400088e-21 3.516674512592439121e-23 1.369999052532802883e-22 1.398958904984117642e-21 2.627450514749010297e-21 0.000000000000000000e+00 7.913874288551473786e-22 2.234681239852447378e-21 1.905024024134410369e-21 3.141307101492195546e-20 2.277000146391445980e+02 3.254976414741172034e-20 3.003328243138916428e-20 4.593306637307851548e-21 3.523566731892229814e-25 7.031142425987315069e-21 3.505983200060669670e-23 1.367078770214083494e-22 1.398922821502374973e-21 2.448635322075391415e-21 0.000000000000000000e+00 8.122793054807625985e-22 2.883399960662386292e-21 1.906521030748303929e-21 3.151372426558055573e-20 2.280000146198825917e+02 3.183569162940710131e-20 3.004581206760003365e-20 4.270835051744264367e-21 3.502133399935059900e-25 7.026793817235319361e-21 3.493154383285492289e-23 1.363574559818650080e-22 1.398884913806658523e-21 2.500570320319988569e-21 0.000000000000000000e+00 8.022849869294549835e-22 2.310214917387415649e-21 1.908317372870711622e-21 3.143594535195660810e-20 2.282500054764512072e+02 2.990214734992213425e-20 3.005626168022260103e-20 3.878592449173559741e-21 3.484273411597744068e-25 7.023153060887681413e-21 3.482464335486302119e-23 1.360654491103325359e-22 1.398841704702056544e-21 2.749141668620505595e-21 0.000000000000000000e+00 8.131683521629250316e-22 2.477885855962715456e-21 1.909805674639887277e-21 3.142816902088114333e-20 2.285000145878915987e+02 3.182980382870169218e-20 3.006671989362300657e-20 3.801614523990002496e-21 3.466413605777664123e-25 7.019475814556277092e-21 3.471773729755801791e-23 1.357734209158282224e-22 1.398773679282647697e-21 2.688249372739271036e-21 0.000000000000000000e+00 8.187698165239565051e-22 2.767817717434017360e-21 1.911224703326604924e-21 3.144709573262518850e-20 2.287500054644808074e+02 3.176342757233968543e-20 3.007718517321376454e-20 3.711442318682095627e-21 3.448555102593713929e-25 7.015798837706467453e-21 3.461084128489299092e-23 1.354814140209103011e-22 1.398705747327137364e-21 2.500656810787524285e-21 0.000000000000000000e+00 8.193083261706940200e-22 2.196030584635873349e-21 1.912643628513986915e-21 3.138494134082920919e-20 2.290000145560403269e+02 3.193904404863600045e-20 3.008765903670955323e-20 4.491146333660377018e-21 3.430900101083651239e-25 7.012153573322843954e-21 3.450393975182569626e-23 1.351893858496282312e-22 1.398659875365474576e-21 2.477638489795920392e-21 0.000000000000000000e+00 8.228375803031183318e-22 2.460215895847469337e-21 1.914062657087862748e-21 3.151373808311534303e-20 2.293000145369962013e+02 3.315105841043625029e-20 3.010023752756759369e-20 4.672916629147679488e-21 3.410083435738435478e-25 7.007805002774473328e-21 3.437566560915404983e-23 1.348389648098303952e-22 1.398622527464279729e-21 2.305515959602252756e-21 0.000000000000000000e+00 8.219782569213529421e-22 2.730650795059751091e-21 1.915765429344995706e-21 3.156046500542988794e-20 2.295500054454366534e+02 3.137032504518048609e-20 3.011072780635096675e-20 4.347049839928502695e-21 3.392736844369427815e-25 7.004181326869048451e-21 3.426877691574884384e-23 1.345469578777079837e-22 1.398590059938009515e-21 2.456021025598196277e-21 0.000000000000000000e+00 8.173032459722596042e-22 2.670401312555551557e-21 1.917184354713162334e-21 3.152924549995706248e-20 2.298000145053665335e+02 3.208796044802170038e-20 3.012122664208658282e-20 4.408571257684177381e-21 3.375559007188250737e-25 7.000557383071995404e-21 3.416188279822422578e-23 1.342549297433715601e-22 1.398525631287277043e-21 2.102771893495618081e-21 0.000000000000000000e+00 8.074940816484317298e-22 2.465294525508415654e-21 1.918603383107511026e-21 3.150458818131993125e-20 2.300500054336013420e+02 3.372243764865718121e-20 3.013173250295847168e-20 4.590659579432792814e-21 3.358448516989068321e-25 6.996933701013448544e-21 3.405499879185739451e-23 1.339629227881279506e-22 1.398461426057580648e-21 2.483938956904405166e-21 0.000000000000000000e+00 8.126803829405176783e-22 2.808394581025485410e-21 1.920022308588028959e-21 3.159638125538587895e-20 2.303000144738741994e+02 3.335443167342471233e-20 3.014224690396460688e-20 4.890074624398395858e-21 3.341336787121503828e-25 6.993319904513372969e-21 3.394810942286609783e-23 1.336708946767523171e-22 1.398407398828792600e-21 2.196531501841542285e-21 0.000000000000000000e+00 7.995509811527613393e-22 2.598459018219248212e-21 1.921441336870806122e-21 3.161102535154496535e-20 2.306000144550443736e+02 3.142813642585219014e-20 3.015487398473105493e-20 5.015940290413835174e-21 3.321317943344178079e-25 6.989014835895132738e-21 3.381985000115944681e-23 1.333204736367041713e-22 1.398373852400494444e-21 2.145585811984812763e-21 0.000000000000000000e+00 7.861787907134876348e-22 3.053973948451848829e-21 1.923144109129155576e-21 3.167875682204971385e-20 2.308500054147714593e+02 3.323363862201792818e-20 3.016540470921736119e-20 4.322862677614983928e-21 3.304702105856563294e-25 6.985427412915937829e-21 3.371297368045075783e-23 1.330284666446753469e-22 1.398345980398619308e-21 1.978048779730495832e-21 0.000000000000000000e+00 7.758604271184829436e-22 2.882319000612237380e-21 1.924563034788420496e-21 3.155844619024632765e-20 2.311000144237699487e+02 3.173853072409706768e-20 3.017594394697339986e-20 4.004327141866818767e-21 3.288085708287288865e-25 6.981813642391484277e-21 3.360609209772084746e-23 1.327364385698303632e-22 1.398292187702759952e-21 1.706183891953377555e-21 0.000000000000000000e+00 7.730740642948479061e-22 2.888107877236899667e-21 1.925959650633127991e-21 3.151033346122161917e-20 2.313500054030688773e+02 3.295804921239319522e-20 3.018649016895593199e-20 4.243221371496330991e-21 3.271475196551648989e-25 6.978189982380965365e-21 3.349922070061441609e-23 1.324444315549402895e-22 1.398228366248229944e-21 2.016510196688061884e-21 0.000000000000000000e+00 7.730896188728335405e-22 3.137890523484029857e-21 1.927354448492520578e-21 3.159308454700636851e-20 2.316000143926305270e+02 3.194307156294263882e-20 3.019704488744569674e-20 4.567025636330254304e-21 3.254863488134108220e-25 6.974566062497535941e-21 3.339234410580333724e-23 1.321524035027988978e-22 1.398164613656379846e-21 1.964467741452845031e-21 0.000000000000000000e+00 7.647760996826194216e-22 3.316862748889670940e-21 1.928749346838242391e-21 3.166232662146647706e-20 2.319000143740113344e+02 3.172875390727504910e-20 3.020972029427952503e-20 4.939462594253678359e-21 3.235138798214504825e-25 6.970318997634074040e-21 3.326410014766821247e-23 1.318019824625046976e-22 1.398130090129831715e-21 1.984246854289690271e-21 0.000000000000000000e+00 7.774941434196177013e-22 3.112528828526008977e-21 1.930423164561670789e-21 3.171025364213337877e-20 2.321500053844496847e+02 3.303338488479438012e-20 3.022029124476076485e-20 4.708680189283493220e-21 3.219002392170867486e-25 6.966782827528647992e-21 3.315723682736977697e-23 1.315099754112415843e-22 1.398102605515112419e-21 2.167135512184031256e-21 0.000000000000000000e+00 7.837359068953636291e-22 3.198106224081993294e-21 1.931817962594802194e-21 3.170516271280214387e-20 2.324000143430861840e+02 3.162267148424372390e-20 3.023087066497403838e-20 4.609023320244149265e-21 3.202864827607920034e-25 6.963227954846940951e-21 3.305036841468924221e-23 1.312179473952229460e-22 1.398062194694194499e-21 1.780997727020449275e-21 0.000000000000000000e+00 7.954214590942410682e-22 3.082084080016661689e-21 1.933212860767980620e-21 3.166463755677714821e-20 2.327000143245948891e+02 2.925635175286938877e-20 3.024357568017932198e-20 4.832030649622405406e-21 3.183668129816186524e-25 6.958922911616238528e-21 3.292213436349634458e-23 1.308675263547793639e-22 1.397986075870849409e-21 1.977617118364057577e-21 0.000000000000000000e+00 7.973648668716518113e-22 3.137372236640141432e-21 1.934886678492122590e-21 3.172625450262176825e-20 2.329500053659583045e+02 3.079167528709445614e-20 3.025417127624326084e-20 4.373009169654438921e-21 3.167764590143697002e-25 6.955335505168770359e-21 3.281527937392720208e-23 1.305755192673935914e-22 1.397922726639950893e-21 1.992728295114464115e-21 0.000000000000000000e+00 8.097967009651047228e-22 2.863378648769101232e-21 1.936281476697797382e-21 3.164430368418106914e-20 2.332000142938817930e+02 3.117649420558185794e-20 3.026477531531948924e-20 4.189689169003049374e-21 3.151859912591960944e-25 6.951788839202292452e-21 3.270841940041814713e-23 1.302834912872499121e-22 1.397888332604968013e-21 2.004807728396389659e-21 0.000000000000000000e+00 8.098991408438307898e-22 2.820873294629421551e-21 1.937676374699615815e-21 3.162588702829800638e-20 2.334500053544655600e+02 3.107895113956936330e-20 3.027538627284600394e-20 4.757171884921928896e-21 3.136301290223621344e-25 6.948252687437288121e-21 3.260156975123408084e-23 1.299914841774134199e-22 1.397861235551486431e-21 2.120341658665880473e-21 0.000000000000000000e+00 8.130921788028847848e-22 3.014903730513025500e-21 1.939071173012528417e-21 3.174092783238554792e-20 2.337000142633001190e+02 3.210408078712363066e-20 3.028600565671326643e-20 5.036530377584516915e-21 3.120827765866023043e-25 6.944716287571293556e-21 3.249471518754882798e-23 1.296994562195669407e-22 1.397834209460515832e-21 1.626497792929957110e-21 0.000000000000000000e+00 8.120518894903191212e-22 3.213607653339861266e-21 1.940460315329786142e-21 3.178375785451203047e-20 2.340000142450138298e+02 3.143370841573090952e-20 3.029875857370334686e-20 5.016476711259806715e-21 3.102261586075039811e-25 6.940472760572206249e-21 3.236649790851125429e-23 1.293490351788839105e-22 1.397759170746095662e-21 1.431013946533744716e-21 0.000000000000000000e+00 8.136647847674412471e-22 3.164468933487502349e-21 1.942123078827814463e-21 3.177761851339115892e-20 2.342500053361792425e+02 3.105254664733742629e-20 3.030939404245477054e-20 4.874174637983170795e-21 3.086823780061701209e-25 6.936936613775873975e-21 3.225965702576958404e-23 1.290570280333259082e-22 1.397696721634372181e-21 1.194530457298330399e-21 0.000000000000000000e+00 8.173430965010279745e-22 3.139689615692806173e-21 1.943508665783012416e-21 3.175278125450554176e-20 2.345000142146406574e+02 3.056874953636113214e-20 3.032003791091811979e-20 4.348138752876148892e-21 3.071384875621919351e-25 6.933420138476828033e-21 3.215281134242053356e-23 1.287650001109573766e-22 1.397648580866218849e-21 2.207487594115067482e-21 0.000000000000000000e+00 8.123693244422905963e-22 3.269639501060700318e-21 1.944894351325104729e-21 3.175311736083645317e-20 2.348000141964788554e+02 3.182525474767228356e-20 3.033282017592097432e-20 4.375173624965329424e-21 3.052990498027868521e-25 6.929236375050549836e-21 3.202460482053010541e-23 1.284145790701289378e-22 1.397616537540522230e-21 2.293219045447443327e-21 0.000000000000000000e+00 8.161584161430109320e-22 3.135972573043894438e-21 1.946557114823823300e-21 3.176091411631786041e-20 2.350500053180173836e+02 3.253303426038011561e-20 3.034348007345170672e-20 4.798588447823083022e-21 3.037964004668363248e-25 6.925750038093597979e-21 3.191777298749345474e-23 1.281225718890930114e-22 1.397589918160216178e-21 2.411586310072292471e-21 0.000000000000000000e+00 8.129426259038033232e-22 3.568393042818519377e-21 1.947942701947365586e-21 3.188564682394002219e-20 2.353000141663120814e+02 3.193559154309174122e-20 3.035414902395136105e-20 5.244634076477717779e-21 3.022936445787082174e-25 6.922252750120900019e-21 3.182553977103976732e-23 1.278620265239157934e-22 1.397536317550445371e-21 2.155434259712411065e-21 0.000000000000000000e+00 8.133294348094091952e-22 3.450980426321943879e-21 1.949328387322257464e-21 3.193407507343784885e-20 2.356000141482735160e+02 3.124372999698379389e-20 3.036696151208549433e-20 5.276181396364021414e-21 3.005032676088678566e-25 6.918052100675992080e-21 3.171838436971748878e-23 1.275569635451929295e-22 1.397461846352447057e-21 2.298270356711740499e-21 0.000000000000000000e+00 8.069538321091434570e-22 3.624223136188560890e-21 1.950991150821658761e-21 3.197959730734300888e-20 2.358500052999787613e+02 3.223148776046594900e-20 3.037764656269879949e-20 4.816770484797206209e-21 2.990235902514773639e-25 6.914559574184075499e-21 3.162909504475310898e-23 1.273027533785957921e-22 1.397405566410024670e-21 2.011481602916829300e-21 0.000000000000000000e+00 8.118948169618267753e-22 3.139804928839698244e-21 1.952376738112401483e-21 3.184586555339470009e-20 2.361000141183110372e+02 3.132159837994314607e-20 3.038833995545529991e-20 4.469262661235691020e-21 2.975438083267538185e-25 6.911108209837879217e-21 3.153980279291842140e-23 1.270485252472180071e-22 1.397379258131924606e-21 1.879316307845552335e-21 0.000000000000000000e+00 8.161074899114422821e-22 3.070459973517727656e-21 1.953762423321225537e-21 3.178995924680970956e-20 2.364000141003944009e+02 3.160029145767012953e-20 3.040118157681200359e-20 4.527881097120934664e-21 2.957854312739161141e-25 6.906966728287800003e-21 3.143266038276679328e-23 1.267434622683711756e-22 1.397348976249103419e-21 1.549317477708930867e-21 0.000000000000000000e+00 8.065359964154816378e-22 3.539728988561740705e-21 1.955412085875485579e-21 3.184043933029527095e-20 2.366500052820620681e+02 3.172851193038922067e-20 3.041189087735342809e-20 4.465930689570108034e-21 2.943273745981354622e-25 6.903497309308714479e-21 3.134338197419390215e-23 1.264892520713059535e-22 1.397307124412248938e-21 1.781540992538398724e-21 0.000000000000000000e+00 8.043930346772087350e-22 3.200215220249301759e-21 1.956775717344759715e-21 3.181739544826087211e-20 2.369000140706341710e+02 3.230467130144602072e-20 3.042260849359177971e-20 4.435065786455630937e-21 2.928692152312743924e-25 6.900010746637581946e-21 3.125410075421465265e-23 1.262350239701905887e-22 1.397248483945066352e-21 1.388704423548350413e-21 0.000000000000000000e+00 8.025480537002481421e-22 3.840362854434156149e-21 1.958139444854737105e-21 3.187380680423519903e-20 2.372000140528382701e+02 3.078946959536357387e-20 3.043547914986838155e-20 4.549866993514428032e-21 2.911605069214939576e-25 6.895827024978045178e-21 3.114697169376090369e-23 1.259299609912209886e-22 1.397178196955044124e-21 1.367871853560452336e-21 0.000000000000000000e+00 8.033819087399359489e-22 3.791776902183273023e-21 1.959775860242616858e-21 3.189476188944319603e-20 2.374500052642661103e+02 3.182798033334177034e-20 3.044621261848224950e-20 5.045261935870475571e-21 2.897418901270448019e-25 6.892371700500012453e-21 3.105770450415951127e-23 1.256757507638933226e-22 1.397150580381715352e-21 1.955458778404492125e-21 0.000000000000000000e+00 8.012063385002185441e-22 3.524267191221462907e-21 1.961139491874224319e-21 3.197862387979470634e-20 2.377000140232782428e+02 3.242772261934207442e-20 3.045695437640427748e-20 5.608139991993687210e-21 2.883232719113753594e-25 6.888920358252380220e-21 3.096843462194294077e-23 1.254215226928368295e-22 1.397127233117960255e-21 2.466314458780690316e-21 0.000000000000000000e+00 8.122969597726436109e-22 3.650611532787043853e-21 1.962503219222960372e-21 3.213135693926864362e-20 2.380000140056018552e+02 3.171529652400776012e-20 3.046985396951911773e-20 5.018777150089176502e-21 2.866238125520502386e-25 6.884790404101955986e-21 3.086131928298219262e-23 1.251164597137456833e-22 1.397090989012618266e-21 2.505129693397341846e-21 0.000000000000000000e+00 8.166783612384666117e-22 3.162897122548735399e-21 1.964139634611492007e-21 3.199645816049456295e-20 2.383000139879699475e+02 3.165240071054556466e-20 3.048276438870694292e-20 4.429510410365521958e-21 2.849243531924731672e-25 6.880706457345757516e-21 3.075420918824830272e-23 1.248113967346093276e-22 1.397021605485727313e-21 2.964828824478886179e-21 0.000000000000000000e+00 8.631101989410243009e-22 3.619580018000859356e-21 1.965776050000265888e-21 3.200988294133661757e-20 2.385500052399915774e+02 3.121546860251876896e-20 3.049353095510456769e-20 4.525254557627178074e-21 2.835268511311399909e-25 6.877303292306352217e-21 3.066495793950568321e-23 1.245571864660027904e-22 1.396963853864293159e-21 2.802844065480813699e-21 0.000000000000000000e+00 9.132989863989460882e-22 3.970479195751303640e-21 1.967139681853301126e-21 3.206123852696780508e-20 2.388000139586818875e+02 3.173916655389975621e-20 3.050430577462032930e-20 4.411999933418770059e-21 2.821494697636354788e-25 6.873892773632489175e-21 3.057570416721916758e-23 1.243029584359485982e-22 1.396905885144002627e-21 2.583967561846751013e-21 0.000000000000000000e+00 9.547399658023907677e-22 4.410346574753770491e-21 1.968503408982092969e-21 3.209534432969572747e-20 2.391000139411678731e+02 3.010097519199163330e-20 3.051724499614723959e-20 4.212275200054302448e-21 2.804966698601260397e-25 6.869793582483652079e-21 3.046860832800014287e-23 1.239978954566923420e-22 1.396836146881275726e-21 3.049204435961522191e-21 0.000000000000000000e+00 1.011585013002908780e-21 4.413505640709996006e-21 1.970130517364803384e-21 3.212302012144458605e-20 2.393500052224775061e+02 3.280141618525487028e-20 3.052803553695145605e-20 4.277956627105425913e-21 2.791329849787623533e-25 6.866377711339485552e-21 3.037936906282845857e-23 1.237436851583035270e-22 1.396778099658914006e-21 3.177428547719996973e-21 0.000000000000000000e+00 1.074138685963144905e-21 4.023347947364363428e-21 1.971473142453878228e-21 3.210451829908612028e-20 2.396000139120752692e+02 3.104463607871564605e-20 3.053883430462300504e-20 5.098671940784341111e-21 2.777756044667061858e-25 6.862973302476127370e-21 3.029012740147540473e-23 1.234894571578328601e-22 1.396752406076054406e-21 2.975858250640367098e-21 0.000000000000000000e+00 1.132033410811603849e-21 4.100093362645429116e-21 1.972815861037431367e-21 3.222614378527803744e-20 2.399000138946779543e+02 3.528361120884643835e-20 3.055180223093712790e-20 5.571583459710442455e-21 2.761468045611620137e-25 6.858889375597123847e-21 3.018304622361526012e-23 1.231843941784579495e-22 1.396725024489347750e-21 3.332741767142394625e-21 0.000000000000000000e+00 1.209770340773670327e-21 4.452599306282265842e-21 1.974427067241320670e-21 3.240001799914723553e-20 2.402000138773240678e+02 3.554452966026613852e-20 3.056478089644226785e-20 4.578266345741927497e-21 2.745586109528631116e-25 6.854805468716463786e-21 3.007597065153540692e-23 1.228793311990388639e-22 1.396682497161921412e-21 3.641843882789187667e-21 0.000000000000000000e+00 1.175370276011039937e-21 4.500475164726919258e-21 1.976038273445443566e-21 3.229434879479863274e-20 2.404500051985859272e+02 3.208605524925888876e-20 3.057560426946241294e-20 4.320624522713098765e-21 2.732389199253597420e-25 6.851402333623003145e-21 2.998674842588746424e-23 1.226251208600235535e-22 1.396625203114646979e-21 3.507378813241805592e-21 0.000000000000000000e+00 1.081922499585796308e-21 4.559163424273398080e-21 1.977380898749089200e-21 3.225851598550144196e-20 2.407000138484970648e+02 3.251293142330758393e-20 3.058643583335076314e-20 4.937672130459339122e-21 2.719199279878154135e-25 6.847998963426597794e-21 2.989752398561196145e-23 1.223708928999093004e-22 1.396567965128921985e-21 3.532375209046464320e-21 0.000000000000000000e+00 9.949203732870719494e-22 4.685357406566671507e-21 1.978723617119497942e-21 3.237448819453533578e-20 2.410000138312582578e+02 3.077861087074406056e-20 3.059944306987709767e-20 5.460091735985885799e-21 2.703599280774572580e-25 6.843976516554534498e-21 2.979046365837577423e-23 1.220658299203732060e-22 1.396525674022470337e-21 3.460815472309439287e-21 0.000000000000000000e+00 8.970890930898068254e-22 5.188000793112273285e-21 1.980334823324238490e-21 3.253557583472527908e-20 2.412500051813470918e+02 3.309015425186506450e-20 3.061029022469232100e-20 5.338236790070544076e-21 2.690599730569952234e-25 6.840654237729109751e-21 2.970125425160233118e-23 1.218116195520444050e-22 1.396503191508007607e-21 3.036883369694917191e-21 0.000000000000000000e+00 8.795445597557304412e-22 5.807347366612659909e-21 1.981677448782704818e-21 3.258674147133474222e-20 2.415000138026221350e+02 3.407705136972315233e-20 3.062114554426467734e-20 4.529555082979478113e-21 2.677601949666456654e-25 6.837331730617224772e-21 2.961204276718137323e-23 1.215573916210495214e-22 1.396480768602549127e-21 2.827194042669570031e-21 0.000000000000000000e+00 8.529441703863651939e-22 5.070913441008032298e-21 1.983020166999317897e-21 3.233037909753336204e-20 2.418000137854972706e+02 3.348770256324015107e-20 3.063418125479681375e-20 4.906713897314221386e-21 2.662017950556036704e-25 6.833296877508583331e-21 2.950499812865407889e-23 1.212523286413975703e-22 1.396417934596229218e-21 2.495257721485182914e-21 0.000000000000000000e+00 8.300332990275212820e-22 4.756038842897074719e-21 1.984630081565644310e-21 3.232123656110603388e-20 2.421000137684148683e+02 3.368912658775255918e-20 3.064722761811579855e-20 5.898152712258895296e-21 2.646433951443409947e-25 6.829254646299476733e-21 2.939795949133728651e-23 1.209472656617024081e-22 1.396349649675778342e-21 2.510871391475250783e-21 0.000000000000000000e+00 8.188678609779440946e-22 5.165928637570268458e-21 1.986231745020401241e-21 3.256150679813014055e-20 2.423500051578295427e+02 3.082278026447456407e-20 3.065810734103779158e-20 5.405597916541991273e-21 2.633759223297852151e-25 6.825902857152770470e-21 2.930876832551929515e-23 1.206930552533841120e-22 1.396305278469001718e-21 2.950245162868922831e-21 0.000000000000000000e+00 8.221678805100016949e-22 5.205959059593495923e-21 1.987566418671163760e-21 3.252891660117665294e-20 2.426000137400380936e+02 3.332674439373916236e-20 3.066899519291114755e-20 4.615704216276938627e-21 2.621291262834464811e-25 6.822580372055384202e-21 2.921957527762663212e-23 1.204388273621150365e-22 1.396283123133760784e-21 3.065719373820343140e-21 0.000000000000000000e+00 8.083663217144602367e-22 5.026875876696706447e-21 1.988901184112163836e-21 3.239879412571512100e-20 2.429000137230680991e+02 3.352344181251058168e-20 3.068206989721196500e-20 4.134010373894057685e-21 2.606330224719721988e-25 6.818593528128075356e-21 2.911255296780379799e-23 1.201337643823055692e-22 1.396256618405109665e-21 2.794377314913321466e-21 0.000000000000000000e+00 8.148427225132154722e-22 5.593430176296659980e-21 1.990502847567521116e-21 3.241386371429614967e-20 2.432000137061399698e+02 3.192743777798019617e-20 3.069515520449677970e-20 4.503602907473113063e-21 2.591387738631137520e-25 6.814606680017768546e-21 2.900553690517463197e-23 1.198287014024535490e-22 1.396201513762797533e-21 2.916263632162463886e-21 0.000000000000000000e+00 8.114031299732163736e-22 5.348956175863265951e-21 1.992104511023101833e-21 3.244412453000503324e-20 2.434500051345244742e+02 3.342926438193297288e-20 3.070606734329378637e-20 4.847439682983829008e-21 2.578940796986308956e-25 6.811284419895549028e-21 2.891636472759311159e-23 1.195744909545077397e-22 1.396147362080438860e-21 2.957613829076049109e-21 0.000000000000000000e+00 8.108933268314895682e-22 4.807391589141416657e-21 1.993439184881919706e-21 3.242233861988633769e-20 2.437000136780190473e+02 3.334578742271207293e-20 3.071698757534940790e-20 4.752687899563169995e-21 2.566493003189158066e-25 6.807961933184268073e-21 2.882719087241302751e-23 1.193202631026059935e-22 1.396093262278587120e-21 2.985884359555313512e-21 0.000000000000000000e+00 8.188086017645126648e-22 5.646307101435924040e-21 1.994773950116230635e-21 3.255579392956386281e-20 2.440000136612018196e+02 3.249867259421483673e-20 3.073010109102560082e-20 4.584195958450964485e-21 2.551927130792723749e-25 6.803975104185668270e-21 2.872019181107241003e-23 1.190152001226411964e-22 1.396066662299858210e-21 2.817156052585326416e-21 0.000000000000000000e+00 8.252579159697662232e-22 5.795318734963198196e-21 1.996375613572403426e-21 3.255458014180595505e-20 2.443000136444258601e+02 3.391113824152726585e-20 3.074322516004603604e-20 4.919171703722346781e-21 2.537402456280266572e-25 6.799988278277251650e-21 2.861319925648074353e-23 1.187101371426344341e-22 1.396042865689816852e-21 3.191510620648455539e-21 0.000000000000000000e+00 8.325701358344497063e-22 6.112072509908455750e-21 1.997977277028796269e-21 3.270743168263834957e-20 2.445500051114291011e+02 3.244167258937400295e-20 3.075416956298427355e-20 4.622447508166804431e-21 2.525301331715615178e-25 6.796679735036539155e-21 2.852404685557865822e-23 1.184559266554181092e-22 1.396009429919012532e-21 3.269839836833121552e-21 0.000000000000000000e+00 8.219922151765162476e-22 5.247658905348543483e-21 1.999311951093795098e-21 3.253071173122758072e-20 2.448000136165573508e+02 3.282637309814362938e-20 3.076512202360211003e-20 4.446014474620176554e-21 2.513208815072832662e-25 6.793391508124367464e-21 2.843489299109365350e-23 1.182016988425301977e-22 1.395955550793931579e-21 3.541810590504405265e-21 0.000000000000000000e+00 8.248501014345456120e-22 5.682928443925969419e-21 2.000627195287736141e-21 3.261742483685940839e-20 2.451000135998908434e+02 3.241823179792840828e-20 3.077827416885977041e-20 4.756040861510751612e-21 2.498698289563175911e-25 6.789445771390592963e-21 2.832791814901585170e-23 1.178966358624121396e-22 1.395890963844050716e-21 3.188414760380740510e-21 0.000000000000000000e+00 8.311554555067561153e-22 5.715785056365624156e-21 2.002204288295703608e-21 3.264226864057796888e-20 2.454000135832650358e+02 3.469847706290728145e-20 3.079143681798602541e-20 4.871678139040999886e-21 2.484377543228320180e-25 6.785509410570009818e-21 2.822095008775933922e-23 1.175915728822527041e-22 1.395856506417216124e-21 3.364526966386927383e-21 0.000000000000000000e+00 8.247930207751923259e-22 5.476910783073613938e-21 2.003781381303884732e-21 3.264757301240181729e-20 2.456500050885405528e+02 3.187108654856259951e-20 3.080241333383279582e-20 4.194979812310835929e-21 2.472624695837445241e-25 6.782232066888439554e-21 2.813181829600367973e-23 1.173373623561182063e-22 1.395836954591202519e-21 3.467463767792040560e-21 0.000000000000000000e+00 8.279998056743739322e-22 5.495081188871931299e-21 2.005095580893632662e-21 3.257719032028105173e-20 2.459000135556455575e+02 3.275890948166809560e-20 3.081339787189464582e-20 4.214464097506471968e-21 2.460871051020300782e-25 6.778954501628296664e-21 2.804268526490919168e-23 1.170831345818952427e-22 1.395817452253953789e-21 3.346769265471282585e-21 0.000000000000000000e+00 8.299679774694388192e-22 5.345348896809117239e-21 2.006409869651327608e-21 3.255199484214071684e-20 2.462000135391277240e+02 3.261993897626433615e-20 3.082658846554292848e-20 4.524850796754588205e-21 2.446982970415286707e-25 6.775059403303714901e-21 2.793573566744674192e-23 1.167780716016259925e-22 1.395756377803109815e-21 3.689845697621976088e-21 0.000000000000000000e+00 8.233623832960950549e-22 4.684115184716588550e-21 2.007986962660076355e-21 3.254047707266920679e-20 2.465000135226500788e+02 3.252796248525796504e-20 3.083979024456265317e-20 4.681533440087609721e-21 2.433259894245956707e-25 6.771167011785600058e-21 2.784612438165337959e-23 1.165112811563988707e-22 1.395692681511217089e-21 3.892948516831388220e-21 0.000000000000000000e+00 8.172768313411745195e-22 5.189568791200305018e-21 2.009564055669036503e-21 3.267435370887493017e-20 2.468000135062124798e+02 3.318050066093136893e-20 3.085300248309735955e-20 4.605035957532005020e-21 2.419536818074794131e-25 6.767274621357174119e-21 2.775707271189018389e-23 1.162457051475335131e-22 1.395647928354401525e-21 3.462833460092857924e-21 0.000000000000000000e+00 8.130997354521324887e-22 4.273403747023271630e-21 2.011141148678207300e-21 3.249355714549673416e-20 2.470500050597044606e+02 3.148707787073518324e-20 3.086402027256318551e-20 4.623081615443287333e-21 2.408108340127797349e-25 6.764031066559985935e-21 2.768287297710773968e-23 1.160243992719862187e-22 1.395628659721736573e-21 3.459502220158234626e-21 0.000000000000000000e+00 8.178349080539452709e-22 3.716681035685486793e-21 2.012455348521427924e-21 3.243725417930850329e-20 2.473000134789051572e+02 3.358959295100962670e-20 3.087504603592816016e-20 4.295870675184441868e-21 2.396679383821479900e-25 6.760787293457937395e-21 2.760867510174966626e-23 1.158030784660127432e-22 1.395609440619902079e-21 3.908043918976513353e-21 0.000000000000000000e+00 8.222547169068252818e-22 3.928348408194518187e-21 2.013769637027291355e-21 3.247813441725661877e-20 2.476000134625736848e+02 3.277133177508714561e-20 3.088828603897760519e-20 4.123193287238070202e-21 2.382991196995447135e-25 6.756894899391581759e-21 2.751964979479782388e-23 1.155375024570534402e-22 1.395559486189068684e-21 3.406524932790036903e-21 0.000000000000000000e+00 8.246334701162696133e-22 4.114631404725455319e-21 2.015330880300919936e-21 3.243424796730346621e-20 2.479000134462817471e+02 3.397844833953156137e-20 3.090153642919837357e-20 5.144663920389937791e-21 2.369668120795899307e-25 6.753002524882860392e-21 2.743063455053604384e-23 1.152719264480591309e-22 1.395496126888394296e-21 3.727319727858620358e-21 0.000000000000000000e+00 8.162940431527817758e-22 3.592680229689714187e-21 2.016884619471080466e-21 3.256488041299394124e-20 2.482000134300292018e+02 3.246875182476715841e-20 3.091479719323432168e-20 5.432344901665793053e-21 2.356345044594602014e-25 6.749110151414588070e-21 2.734162946724680929e-23 1.150063504390299565e-22 1.395440928818934494e-21 3.537010649680758641e-21 0.000000000000000000e+00 8.313501243772754473e-22 4.163590898207325535e-21 2.018438358641444874e-21 3.267044450068911582e-20 2.484500050311933421e+02 3.409879182789730895e-20 3.092585537370727227e-20 4.735491384410856955e-21 2.345298241197995579e-25 6.745866615977439759e-21 2.726746888555003494e-23 1.147850445212807221e-22 1.395421943485848278e-21 3.086455717738576832e-21 0.000000000000000000e+00 8.297827363112470477e-22 4.409867898472419466e-21 2.019733097854890148e-21 3.255829006843123653e-20 2.487000134030287484e+02 3.248833076722525205e-20 3.093692148331376610e-20 4.504836766747672296e-21 2.334349156605818962e-25 6.742622862837114178e-21 2.719331051268505756e-23 1.145637237572375298e-22 1.395403007725201071e-21 3.256316869509446122e-21 0.000000000000000000e+00 8.376928163260484232e-22 5.044959221653199855e-21 2.021027923925836818e-21 3.264432781339236008e-20 2.490000133868805108e+02 3.220392762737111780e-20 3.095020984565502551e-20 5.450748243568467864e-21 2.321210695774567153e-25 6.738751249392276139e-21 2.710433301555806509e-23 1.142981477481160086e-22 1.395364390820183629e-21 2.683634236113745025e-21 0.000000000000000000e+00 8.418023236972609197e-22 4.889567178423500710e-21 2.022581663096741390e-21 3.272471516294928744e-20 2.493000133707711257e+02 3.358163090155938889e-20 3.096350853294568677e-20 6.376398539076094748e-21 2.308266266085138905e-25 6.734910776286313944e-21 2.701536605081777379e-23 1.140325717389601158e-22 1.395301907881518012e-21 2.695902645149036093e-21 0.000000000000000000e+00 8.475770346455380531e-22 5.739207416524360067e-21 2.024135402267847205e-21 3.304147161805435227e-20 2.496000133547004793e+02 3.202375231142840962e-20 3.097681753188793186e-20 5.854023126702321168e-21 2.295491583225159990e-25 6.731070310202628611e-21 2.692640972286383363e-23 1.137669957297698987e-22 1.395239496887925816e-21 3.030485165711492625e-21 0.000000000000000000e+00 8.571151473745891997e-22 5.262911812753405017e-21 2.025689141439153890e-21 3.290623989339990540e-20 2.499000133386684581e+02 3.254421464478637719e-20 3.099013682919644925e-20 5.188145058714376981e-21 2.282716900363536301e-25 6.727229845121142302e-21 2.683746413746749079e-23 1.135014197205454982e-22 1.395177157849062270e-21 2.691258353832129153e-21 0.000000000000000000e+00 8.434811105109653614e-22 5.297449132663366069e-21 2.027242880610660314e-21 3.278182707428497064e-20 2.501500049970017585e+02 3.349728047888242442e-20 3.100124373071251762e-20 5.215823494746496329e-21 2.272086967050541806e-25 6.724029563530186908e-21 2.676335356852338416e-23 1.132801137521870707e-22 1.395125265350323918e-21 2.406697731306406731e-21 0.000000000000000000e+00 8.526490652878270628e-22 6.525086365738624952e-21 2.028537620120192491e-21 3.299492909106686429e-20 2.504000133120337068e+02 3.216397447323826632e-20 3.101235850725862838e-20 5.362999530520640699e-21 2.261458408426875676e-25 6.720831737628410008e-21 2.668924565919738877e-23 1.130587930384293404e-22 1.395076669585383979e-21 2.243272856790320631e-21 0.000000000000000000e+00 8.551869778384763983e-22 6.433138938727636514e-21 2.029828720400752031e-21 3.299888719457838507e-20 2.507000132961038901e+02 3.286225570366678734e-20 3.102570520202241717e-20 5.469094436265111890e-21 2.248704562950251182e-25 6.717031272820464134e-21 2.660032924839917698e-23 1.127932170291144738e-22 1.395056634084834073e-21 2.275636763978118805e-21 0.000000000000000000e+00 8.605679355548771508e-22 5.593045626120666914e-21 2.031374241788687360e-21 3.287721459985887252e-20 2.510000132802121584e+02 3.201032517571009154e-20 3.103906214654728472e-20 5.748854423238413597e-21 2.236282994940085489e-25 6.713230814554949676e-21 2.651142398008801295e-23 1.125276410197658705e-22 1.395036657987256042e-21 2.230034236834801791e-21 0.000000000000000000e+00 8.710946041842780466e-22 6.482796053542986414e-21 2.032919763176818669e-21 3.309669066056721004e-20 2.513000132643583413e+02 3.307309763359677713e-20 3.105242932760667844e-20 6.100916705347537943e-21 2.223872869013633003e-25 6.709430357476561133e-21 2.642252996673920168e-23 1.122620650103837186e-22 1.394994126756479401e-21 1.858817870520134395e-21 0.000000000000000000e+00 8.828005152382741630e-22 7.048574903392429436e-21 2.034465284565145579e-21 3.326418967728207795e-20 2.516000132485423251e+02 3.123266543022703126e-20 3.106580673198670270e-20 5.537965691978086743e-21 2.211518446667083829e-25 6.705629904932415037e-21 2.633364732233241348e-23 1.119964890009681122e-22 1.394934363692978138e-21 1.867279114435237263e-21 0.000000000000000000e+00 8.971577907769914668e-22 7.336470143069753909e-21 2.036010805953666964e-21 3.324061853356405640e-20 2.518500049632717435e+02 3.202986479568392984e-20 3.107696199968635723e-20 5.491736832560451445e-21 2.201316253144455401e-25 6.702462972569012455e-21 2.625958967029288505e-23 1.117751829826848175e-22 1.394884607308121306e-21 1.761415545572955285e-21 0.000000000000000000e+00 8.858775831233114554e-22 8.308612702773239445e-21 2.037298697828456370e-21 3.346475207865401068e-20 2.521000132222659431e+02 3.299325923595795703e-20 3.108812508859411222e-20 5.229358732153752394e-21 2.191113384448286857e-25 6.699303550947431186e-21 2.618553516040134588e-23 1.115538623185346885e-22 1.394864154558328035e-21 1.673981372632712607e-21 0.000000000000000000e+00 9.038921963628582903e-22 7.231149063696569467e-21 2.038586674934967015e-21 3.317712684209837645e-20 2.524000132065501134e+02 3.324834235683551063e-20 3.110152969065738920e-20 5.109467464735064420e-21 2.178942760871178109e-25 6.695513634210768388e-21 2.609668340211894344e-23 1.112882863090303792e-22 1.394844454299283094e-21 1.804733598509733804e-21 0.000000000000000000e+00 8.926731517440476221e-22 8.799243525171011830e-21 2.040132196324004864e-21 3.355358582369146829e-20 2.527000131908715730e+02 3.320891531634342628e-20 3.111494446769864353e-20 5.049283935896276313e-21 2.166897191880448757e-25 6.691731614804355395e-21 2.600784344398406064e-23 1.110227102994930621e-22 1.394816935245925247e-21 1.427448391670038216e-21 0.000000000000000000e+00 9.040740510723643215e-22 6.915296194311365110e-21 2.041677717713234555e-21 3.309407128832197229e-20 2.530000131752302366e+02 3.297718687099622408e-20 3.112836940656316583e-20 5.032397218918916573e-21 2.154851622888225241e-25 6.687981173180403426e-21 2.591901540733531216e-23 1.107571342899228076e-22 1.394757970752977618e-21 1.355429745820345838e-21 0.000000000000000000e+00 8.957359409049101031e-22 6.805041422110364875e-21 2.043223239102655709e-21 3.307734371541879231e-20 2.533000131596259337e+02 3.373825313009410518e-20 3.114180449410894580e-20 5.105645267526085311e-21 2.143037485458626920e-25 6.684230739677957350e-21 2.583019941516403421e-23 1.104915582803197803e-22 1.394699064589529516e-21 1.426006674084339818e-21 0.000000000000000000e+00 8.951702050954269866e-22 8.104845136260837183e-21 2.044755406896069041e-21 3.339492426291970316e-20 2.536000131440585506e+02 3.268808662430013442e-20 3.115524971720673245e-20 4.809440254301569991e-21 2.131307486067311529e-25 6.680480309701308966e-21 2.574139559214221138e-23 1.102259822706840508e-22 1.394666474529056918e-21 1.170414929836101589e-21 0.000000000000000000e+00 9.009521038615746601e-22 7.680040105238041286e-21 2.046271289918954938e-21 3.325235108512140976e-20 2.538500049241677630e+02 3.347392562401742709e-20 3.116646143457725002e-20 4.872789931328071252e-21 2.121532807465041102e-25 6.677355054687384935e-21 2.566740422220608162e-23 1.100046761945230818e-22 1.394650300503104693e-21 1.352703330191993086e-21 0.000000000000000000e+00 8.845677379686558150e-22 6.304731070766076145e-21 2.047534484302265378e-21 3.298774890267577330e-20 2.541000131181945960e+02 3.225527521386666138e-20 3.117768091019933068e-20 4.641254779416381802e-21 2.111878494293599270e-25 6.674229599955206516e-21 2.559341660703685196e-23 1.097833555878855421e-22 1.394634166692822705e-21 1.035100742587803567e-21 0.000000000000000000e+00 8.866036894738146041e-22 6.298715650743182780e-21 2.048797761624177285e-21 3.295179777032922549e-20 2.544000131027250404e+02 3.393919215464957264e-20 3.119115309734539923e-20 4.065762667501557057e-21 2.100313494889950596e-25 6.670510759299213544e-21 2.550464585767805151e-23 1.095177795781632256e-22 1.394583351108891512e-21 9.734673527461993253e-22 0.000000000000000000e+00 9.061420419013052597e-22 6.024305493001089700e-21 2.050313644647557078e-21 3.283498825338784151e-20 2.547000130872919215e+02 3.273447872413377816e-20 3.120463537201212978e-20 4.651606656872032025e-21 2.088760503337272788e-25 6.666799812357629442e-21 2.541588774944503997e-23 1.092522035684086536e-22 1.394524718611968192e-21 8.701090689569292668e-22 0.000000000000000000e+00 9.103036730808121806e-22 6.819839397856897985e-21 2.051829527671121187e-21 3.307682225617526900e-20 2.550000130718950970e+02 3.322416661176434541e-20 3.121812772112992702e-20 5.207252306987141066e-21 2.077375503921582221e-25 6.663091326024540173e-21 2.532714241523917046e-23 1.089866275586219436e-22 1.394476649289763412e-21 8.448502666830279108e-22 0.000000000000000000e+00 9.074866607405588953e-22 6.982443941235054201e-21 2.053345410694868862e-21 3.320465179035452812e-20 2.553000130565344818e+02 3.238815839450303210e-20 3.123163013164203916e-20 5.171347598756967337e-21 2.065990504504517106e-25 6.659389607032480830e-21 2.523840998981178321e-23 1.087210515488031661e-22 1.394457520806276095e-21 7.535688206196170630e-22 0.000000000000000000e+00 8.931105677249399108e-22 7.147150946954423553e-21 2.054861293718799350e-21 3.324352162028091517e-20 2.556000130412099054e+02 3.274859709824668440e-20 3.124514259050453991e-20 4.354227689673463108e-21 2.054665511606689643e-25 6.655687892426896206e-21 2.514969060979620253e-23 1.084554755389525092e-22 1.394438451776718994e-21 7.607996639607637572e-22 0.000000000000000000e+00 8.871625724139388631e-22 7.561332288463112204e-21 2.056377176742911898e-21 3.323013054381758720e-20 2.559000130259212540e+02 6.765236741466351600e-20 3.125866508468634654e-20 4.382398529649143323e-21 2.043430512179249367e-25 6.651979724262721030e-21 2.506098441374031272e-23 1.081898995290700435e-22 1.394391868748296780e-21 2.940381129705510512e-22 0.000000000000000000e+00 8.972624936200178936e-22 6.243290711101533805e-21 2.057893059767206131e-21 3.296392265761238490e-20 2.562000130106684423e+02 4.210663951496518270e-20 3.127219760116928603e-20 4.674193365877804458e-21 2.032195512750466915e-25 6.648268789115867440e-21 2.497229154213983630e-23 1.079243235191558393e-22 1.394333529522803934e-21 6.974503054072918354e-22 0.000000000000000000e+00 8.760581882314102348e-22 6.069850236380782970e-21 2.059376798159586958e-21 3.298927660914827569e-20 2.564500048742444847e+02 3.436059651124191557e-20 3.128348197796960967e-20 4.918135148686988538e-21 2.022935320384090796e-25 6.645176445279025687e-21 2.489839349817917320e-23 1.077030173691055759e-22 1.394284959698213100e-21 5.145371716555175937e-22 0.000000000000000000e+00 8.808089335770430317e-22 6.297496622471153973e-21 2.060560194967646687e-21 3.307421750186855619e-20 2.567000129853262820e+02 3.348706631135071611e-20 3.129477403177055049e-20 4.853003474519888924e-21 2.013722521490726672e-25 6.642091591139225804e-21 2.482450008726121892e-23 1.074816968358954083e-22 1.394236853578039005e-21 5.833153933390352938e-22 0.000000000000000000e+00 8.815903782213422828e-22 6.424640825767365393e-21 2.061743668687195133e-21 3.310033572763753075e-20 2.570000129701683136e+02 3.300908714143050798e-20 3.130833321084331233e-20 5.346223230361394492e-21 2.002667522049298049e-25 6.638389887252394505e-21 2.473584344959181147e-23 1.072161208258972504e-22 1.394179181667679126e-21 5.516954935073971829e-22 0.000000000000000000e+00 8.544675144989534959e-22 6.773445567538591496e-21 2.063163791003983852e-21 3.325640670141997612e-20 2.573000129550457018e+02 3.257050187772709383e-20 3.132190236459414148e-20 5.347774939394945985e-21 1.991821263292927380e-25 6.634711103698678828e-21 2.464720066875050730e-23 1.069505448158678008e-22 1.394131937629510063e-21 1.433700022790843837e-22 0.000000000000000000e+00 8.693420992443089775e-22 6.536323470984528096e-21 2.064583913320939961e-21 3.321742987751188315e-20 2.576000129399582761e+02 3.342737325819154459e-20 3.133548148006506830e-20 4.749088532592135956e-21 1.981050893464214271e-25 6.631095322254797249e-21 2.455857189478378828e-23 1.066849688058072006e-22 1.394113262348314536e-21 5.211074816818673129e-22 0.000000000000000000e+00 8.471397223112319308e-22 5.829546456283377070e-21 2.066004035638062708e-21 3.300961051818202847e-20 2.579000129249059796e+02 3.141885911961629936e-20 3.134907063648800209e-20 4.837936576066804694e-21 1.970285962753942057e-25 6.627479541888986554e-21 2.447245239994563306e-23 1.064248445313770835e-22 1.394096053714497361e-21 3.770915991117276354e-22 0.000000000000000000e+00 8.701127100056978733e-22 6.389139572758048129e-21 2.067424157955351717e-21 3.313673815403823800e-20 2.582000129098886418e+02 3.178915408473205108e-20 3.136267021568469925e-20 4.838306883171350999e-21 1.959678555877518141e-25 6.623832465442872920e-21 2.439959166573215711e-23 1.061936443485897601e-22 1.394053244161574389e-21 5.581585931164027550e-22 0.000000000000000000e+00 8.775427027488112026e-22 6.023901025135104432e-21 2.068844280272806236e-21 3.308331652701686269e-20 2.585000128949062059e+02 3.198595269424961368e-20 3.137627971416208099e-20 4.351834692972678380e-21 1.949071148999859956e-25 6.620169740988234068e-21 2.432675689986142826e-23 1.059624441657755415e-22 1.393997524542955452e-21 5.106906507537266412e-22 0.000000000000000000e+00 8.824470876720013137e-22 7.177050754991968810e-21 2.070264402590426264e-21 3.325697912172065350e-20 2.588000128799584445e+02 3.285748252329972363e-20 3.138989911901825234e-20 4.583858493750046025e-21 1.938555653987773202e-25 6.616511715885441407e-21 2.425394833628290361e-23 1.057312439829345804e-22 1.393945743043039701e-21 6.043124219924826273e-22 0.000000000000000000e+00 8.994518626890040832e-22 7.537826971326856506e-21 2.071684524908209921e-21 3.338196405513739014e-20 2.591000128650453576e+02 3.314492565116887246e-20 3.140352841736432438e-20 4.866011190930502918e-21 1.928223947184291853e-25 6.612895949386840144e-21 2.418116621167894708e-23 1.055000438000669120e-22 1.393929002038080195e-21 2.971284704576108742e-22 0.000000000000000000e+00 8.887569598620079508e-22 6.986224077157205698e-21 2.073103775696325099e-21 3.330957922698135661e-20 2.594000128501667746e+02 3.224073887016884587e-20 3.141716759632439616e-20 6.095022318626409337e-21 1.917892240379622611e-25 6.609280183687402758e-21 2.410841076550365303e-23 1.052688436171726422e-22 1.393912310270831004e-21 2.750848148908993223e-22 0.000000000000000000e+00 8.970581019852323053e-22 6.343025424268889749e-21 2.074515784973590352e-21 3.339525307383870423e-20 2.597000128353224682e+02 3.460632221507793657e-20 3.143081664303560287e-20 5.149078140084074017e-21 1.907581781701278397e-25 6.605664419838127278e-21 2.403568224002208134e-23 1.050376434342519708e-22 1.393876473902312546e-21 2.301084270380970220e-22 0.000000000000000000e+00 9.080480086297837902e-22 7.739058223030834044e-21 2.075927794251016977e-21 3.354219051747146076e-20 2.600000128205124952e+02 3.143057351197508894e-20 3.144447554464812188e-20 5.053097267187876785e-21 1.897285485913275122e-25 6.602048657483731536e-21 2.396298088035019190e-23 1.048064432513048272e-22 1.393821495538418249e-21 3.521010552006766852e-22 0.000000000000000000e+00 9.134009010712363791e-22 5.588559458524237578e-21 2.077339803528604974e-21 3.311096180417862514e-20 2.603000128057366851e+02 3.398452242547248556e-20 3.145814428832515464e-20 5.163850677983030020e-21 1.886989190124099566e-25 6.598432895924212974e-21 2.389030693449555491e-23 1.045752430683313643e-22 1.393766565511151080e-21 2.947096801769940672e-22 0.000000000000000000e+00 9.150774075059414227e-22 7.087079131364040446e-21 2.078751812806353967e-21 3.342522587426084541e-20 2.605500047975436360e+02 3.253452513594156043e-20 3.146954205238512519e-20 5.605395775306156475e-21 1.878597888238296450e-25 6.595448069416143407e-21 2.382976837100826063e-23 1.043825824113500755e-22 1.393748978988881666e-21 2.663476885216269625e-22 0.000000000000000000e+00 9.216360695085930085e-22 6.797816240971253492e-21 2.079928449570287711e-21 3.344642336620256588e-20 2.608000127811857851e+02 3.432082785911600473e-20 3.148094736421741458e-20 6.385002561116007146e-21 1.870231767419832083e-25 6.592466897997676531e-21 2.376924529391029849e-23 1.041899094299841000e-22 1.393735262680820659e-21 1.787384734116542523e-22 0.000000000000000000e+00 9.266857420828878584e-22 5.471131479388632692e-21 2.081105161602957005e-21 3.335247839744164755e-20 2.611000127665004129e+02 3.308277406636178281e-20 3.149464229074158444e-20 6.140193061420852036e-21 1.860192743521010733e-25 6.588889607412264111e-21 2.369664568648719085e-23 1.039587092469409304e-22 1.393718848785213257e-21 4.202149289550810429e-22 0.000000000000000000e+00 9.245922579655184442e-22 5.509775645331280914e-21 2.082517170881131808e-21 3.332728174002748081e-20 2.614000127518487488e+02 3.368559398712201408e-20 3.150834701237389926e-20 5.213249589608610107e-21 1.850287872804981241e-25 6.585275136867953204e-21 2.362407442765596380e-23 1.037275090638717940e-22 1.393665375119130842e-21 2.191135542041119935e-22 0.000000000000000000e+00 9.320827673906177330e-22 6.240247727234387287e-21 2.083929180159464975e-21 3.330876181471061490e-20 2.617000127372306224e+02 3.401246246951333457e-20 3.152206151633859440e-20 5.091071877178570764e-21 1.840409824505822434e-25 6.581659386687208674e-21 2.355153177947524472e-23 1.034963088807767968e-22 1.393610671896201760e-21 2.833201756615731088e-22 0.000000000000000000e+00 9.564183320617711787e-22 6.138461744595090281e-21 2.085341189437956127e-21 3.328446182671669174e-20 2.620000127226459767e+02 3.349467168334036520e-20 3.153578578987306776e-20 5.278917726305376742e-21 1.830544952522820215e-25 6.578074345623261593e-21 2.347901800713837823e-23 1.032651086976560092e-22 1.393556195230895188e-21 3.583893932563629549e-22 0.000000000000000000e+00 9.525623900129361631e-22 5.622303630354417594e-21 2.086753198716604514e-21 3.323548839389095895e-20 2.623000127080947550e+02 3.395816024677857993e-20 3.154951982022778350e-20 5.195180596737365802e-21 1.820798611532142644e-25 6.574542343186412018e-21 2.340653337901878852e-23 1.030339085145094548e-22 1.393502074674544153e-21 2.912070213326425890e-22 0.000000000000000000e+00 9.672047002568294752e-22 5.925827221481887427e-21 2.088147958144392695e-21 3.328717167130346709e-20 2.626000126935767298e+02 3.650239261653823100e-20 3.156326359466640439e-20 5.026148000309243152e-21 1.811052270540386694e-25 6.571010341488363463e-21 2.333407816671608809e-23 1.028027083313373216e-22 1.393448002506326083e-21 2.614743083699674411e-22 0.000000000000000000e+00 9.806582322561409321e-22 4.736819162307037817e-21 2.089537403169344116e-21 3.308272119004054456e-20 2.629000126790919012e+02 3.356745996982485150e-20 3.157701710046568953e-20 5.108486992000568325e-21 1.801402008795939401e-25 6.567445136704911987e-21 2.326165264510282133e-23 1.025715081481396097e-22 1.393421776036761948e-21 2.024406738137094207e-22 0.000000000000000000e+00 9.752789919135304465e-22 5.102789703137912293e-21 2.090926848194449010e-21 3.316159313737436231e-20 2.632000126646399849e+02 3.411436525380454180e-20 3.159078032491556656e-20 5.534398483768701985e-21 1.791917671903431164e-25 6.563867862842675779e-21 2.318925709237223948e-23 1.023403079649165189e-22 1.393405704645633795e-21 2.855584311529466243e-22 0.000000000000000000e+00 9.732988782370258545e-22 5.428511439432909480e-21 2.092316293219706624e-21 3.329443344536902167e-20 2.635000126502210946e+02 3.347354687014691241e-20 3.160455325531914372e-20 5.467696117658032420e-21 1.782433335009878987e-25 6.560302516427348059e-21 2.311689179008652536e-23 1.021091077816679903e-22 1.393384690240890156e-21 2.120640858587687927e-22 0.000000000000000000e+00 9.748082320719560196e-22 5.064142760212165833e-21 2.093705738245116958e-21 3.323789863811704461e-20 2.638000126358349462e+02 3.615113043790334847e-20 3.161833587899270380e-20 5.160727827827593123e-21 1.773035751192802383e-25 6.556814669703920952e-21 2.304455702322628162e-23 1.018779075983942239e-22 1.393331286608775801e-21 1.635803293083664020e-22 0.000000000000000000e+00 9.782981732284490332e-22 5.244953122194786487e-21 2.095095183270678884e-21 3.322919137247795947e-20 2.641000126214814827e+02 3.348075200562214635e-20 3.163212818326568611e-20 5.445860377926247143e-21 1.763695992603517023e-25 6.553326826050063559e-21 2.297225308024038350e-23 1.016467074150952667e-22 1.393277931400314839e-21 2.729899045592454613e-22 0.000000000000000000e+00 9.567400092316825079e-22 4.945439856392368382e-21 2.096484628296392402e-21 3.324138388294554551e-20 2.644000126071605905e+02 3.394629031562376167e-20 3.164593015548075867e-20 5.615336794254155788e-21 1.754356234013217799e-25 6.549818380191844807e-21 2.289998025309701876e-23 1.014155072317712126e-22 1.393242094263381742e-21 2.473708467018892673e-22 0.000000000000000000e+00 9.605956220261297226e-22 5.319615171743245307e-21 2.097874073322256759e-21 3.333965017959831592e-20 2.647000125928721559e+02 3.407158993017620596e-20 3.165974178299380020e-20 5.362911039114855537e-21 1.745124914618816613e-25 6.546286395000633356e-21 2.282773883733542123e-23 1.011843070484221323e-22 1.393226268115151748e-21 1.958799676369210257e-22 0.000000000000000000e+00 9.512785601222761702e-22 4.753349511783721136e-21 2.099263518348271203e-21 3.322424277151038222e-20 2.650000125786160652e+02 3.255814307209540581e-20 3.167356305317387602e-20 5.402820693409372016e-21 1.735915276502244360e-25 6.542754410937279583e-21 2.275552913211850938e-23 1.009531068650481315e-22 1.393210491250820346e-21 2.640070807089033487e-22 0.000000000000000000e+00 9.717041263280638379e-22 4.920085821980899178e-21 2.100652963374435734e-21 3.326857893077624229e-20 2.653000125643922615e+02 3.363827009281249743e-20 3.168739395340331627e-20 4.860876078419003814e-21 1.726714318533092097e-25 6.539222427568260417e-21 2.268335144028643312e-23 1.007219066816492572e-22 1.393163739034432289e-21 3.842673069247702151e-22 0.000000000000000000e+00 9.783232069976126150e-22 4.172417513501213361e-21 2.102028883165198582e-21 3.309629008557887662e-20 2.656000125502005176e+02 3.345265456098815948e-20 3.170123447107764374e-20 4.756278282723634390e-21 1.717634800890317299e-25 6.535690444894705087e-21 2.261120606841107842e-23 1.004907064982256623e-22 1.393111705230106525e-21 1.732526210778210862e-22 0.000000000000000000e+00 9.659407387200327750e-22 4.550008118321282728e-21 2.103397156679936375e-21 3.314131833592125720e-20 2.659000125360408333e+02 3.384962869381978157e-20 3.171508459360566408e-20 5.788067496586791304e-21 1.708555283246572259e-25 6.532167293788576283e-21 2.253909332685131566e-23 1.002595063147773702e-22 1.393067293725569720e-21 3.161287150137110629e-22 0.000000000000000000e+00 9.796654103522210795e-22 4.787110484204050333e-21 2.104765430194820494e-21 3.335228430193109697e-20 2.662000125219130382e+02 3.423502447311876988e-20 3.172894430840942376e-20 6.235817593674093352e-21 1.699546773758850189e-25 6.528679461251991508e-21 2.246701352980945560e-23 1.000283061313044986e-22 1.393053246267111343e-21 2.121450739918415682e-22 0.000000000000000000e+00 9.847217326569297705e-22 4.619515513212906676e-21 2.106133703709850187e-21 3.342119831002388342e-20 2.665000125078170754e+02 3.395360835020000452e-20 3.174281360292422802e-20 6.374693694792746773e-21 1.690703917031488053e-25 6.525191637807793470e-21 2.239496699538842840e-23 9.979710594780709439e-23 1.393039238806672620e-21 4.001340155741715588e-22 0.000000000000000000e+00 9.905125996233790865e-22 4.884689936461479909e-21 2.107501977225025076e-21 3.349947855099670508e-20 2.668000124937528312e+02 3.443443249970713667e-20 3.175669246459867106e-20 6.574391771652919892e-21 1.681861060303191492e-25 6.521723816378075499e-21 2.232295404565010871e-23 9.956590576428525166e-23 1.393005304607165248e-21 2.592961997257437555e-22 0.000000000000000000e+00 9.883446581267029664e-22 4.153356890657446054e-21 2.108870250740344410e-21 3.345049577157677522e-20 2.671000124797201920e+02 3.424129101151600947e-20 3.177058088089459384e-20 5.701461864768968459e-21 1.673089638088115656e-25 6.518273493550128450e-21 2.225097500667452826e-23 9.933470558073904092e-23 1.392953941865720027e-21 2.936637695942697520e-22 0.000000000000000000e+00 9.896311729229542627e-22 4.161970591310687991e-21 2.110238524255808189e-21 3.330399020453183990e-20 2.674000124657189872e+02 3.476922561500807612e-20 3.178447883928716236e-20 5.165865539294967332e-21 1.664389638494150623e-25 6.514823171063062725e-21 2.217903020862017281e-23 9.910350539716861501e-23 1.392902618383483659e-21 2.581715880767564616e-22 0.000000000000000000e+00 9.966496440985973400e-22 4.543407713217058123e-21 2.111606797771414908e-21 3.327903354892446298e-20 2.677000124517492168e+02 3.349958386468075922e-20 3.179838632726484356e-20 5.922614214777616156e-21 1.655689638899274353e-25 6.511372849234239229e-21 2.210711998578525485e-23 9.887230521357395040e-23 1.392851334164796258e-21 3.325713189778576081e-22 0.000000000000000000e+00 1.007427347268180869e-21 4.630004309692161671e-21 2.112975071287165320e-21 3.343037727819839834e-20 2.680000124378107103e+02 3.314770572591120278e-20 3.181230333232938128e-20 5.939004995448234379e-21 1.647069644041704361e-25 6.507922530698054780e-21 2.203524467667011762e-23 9.864110502995519991e-23 1.392800089213994927e-21 3.442006409672240453e-22 0.000000000000000000e+00 1.006581630978638168e-21 4.043109527812390948e-21 2.114343344803058295e-21 3.336984342395960463e-20 2.683000124239032971e+02 3.320519328597420093e-20 3.182622984199585040e-20 5.736967892327549751e-21 1.638483930154006741e-25 6.504473325266504519e-21 2.196340462404065303e-23 9.840990484631249285e-23 1.392756372396629681e-21 2.061215887063114778e-22 0.000000000000000000e+00 1.007605721103106187e-21 4.160760881887381360e-21 2.115708814734532859e-21 3.336054147246384881e-20 2.686000124100270341e+02 3.485089404154598781e-20 3.184016584379266285e-20 5.844884469962400547e-21 1.629898216265417398e-25 6.501028564650955527e-21 2.189160017499277753e-23 9.817870466264577043e-23 1.392742642987975470e-21 2.483830841811166674e-22 0.000000000000000000e+00 1.018204068505776140e-21 3.950461455040204069e-21 2.117070005599284454e-21 3.336702898101960102e-20 2.689000123961816939e+02 3.307714431669610479e-20 3.185411132526155560e-20 6.527461037560639266e-21 1.621517772304021419e-25 6.497583811690167819e-21 2.181983168101819516e-23 9.794750447895522075e-23 1.392728953592595631e-21 3.797660012325729343e-22 0.000000000000000000e+00 1.022485708175345598e-21 3.883272483407316281e-21 2.118431196464176357e-21 3.349951895543844895e-20 2.692000123823672197e+02 3.321844592709106952e-20 3.186806627395758464e-20 6.865679797726997879e-21 1.613160125630053252e-25 6.494157579993157332e-21 2.174809949807106862e-23 9.771630429524087906e-23 1.392696814953321393e-21 4.076955702968810201e-22 0.000000000000000000e+00 1.013083871513930263e-21 3.694742884384996468e-21 2.119792387329208567e-21 3.355848797333197464e-20 2.695000123685834978e+02 3.329126270333875678e-20 3.188203067744917911e-20 5.983178778410727052e-21 1.604803465559393685e-25 6.490749865372262494e-21 2.167640398663601281e-23 9.748510411150283941e-23 1.392646229585756181e-21 3.538855752326809968e-22 0.000000000000000000e+00 1.009642282461538321e-21 3.853628576257402525e-21 2.121153578194379955e-21 3.341909539814832862e-20 2.698500231610144056e+02 3.484172686749996380e-20 3.189833491844701827e-20 4.944014912298002887e-21 1.595069832093695853e-25 6.486774070595482055e-21 2.159280347849860884e-23 9.721536223404161260e-23 1.392587261174578184e-21 3.200499179614262125e-22 0.000000000000000000e+00 1.023002044906650275e-21 3.999182750564609483e-21 2.122741683245241430e-21 3.328097006258541698e-20 2.702000123365405670e+02 3.483366108875536473e-20 3.191465121280867673e-20 4.863512914341113103e-21 1.585336799783825122e-25 6.482798522240429896e-21 2.151765051416773680e-23 9.696097692943866180e-23 1.392570258298394851e-21 2.893715293248898252e-22 0.000000000000000000e+00 1.015393213020243378e-21 3.469250165314955226e-21 2.124329690213653984e-21 3.322405371977070410e-20 2.705000123228586517e+02 3.248840777732149183e-20 3.192864748599696005e-20 5.869926355514950338e-21 1.577129078322649222e-25 6.479390811979100173e-21 2.146251029569800789e-23 9.675970300889835645e-23 1.392556781360850987e-21 3.980549446459926487e-22 0.000000000000000000e+00 1.007272978875247583e-21 4.142636362742636159e-21 2.125690881079287295e-21 3.347654630993168590e-20 2.708000123092070339e+02 3.411462391923454651e-20 3.194265315755581608e-20 5.743587475736960402e-21 1.569011431633222587e-25 6.475983107086286628e-21 2.140748793404996471e-23 9.655842908833772680e-23 1.392527319402283544e-21 2.201643403655422293e-22 0.000000000000000000e+00 1.006973686536193793e-21 3.750333893635567312e-21 2.127052071945058279e-21 3.341947010923347837e-20 2.711000122955856000e+02 3.391312830167983281e-20 3.195666821512817135e-20 4.794912284755452535e-21 1.560893784942979305e-25 6.472575402784316793e-21 2.135258434032105204e-23 9.635715516775684337e-23 1.392476944636175635e-21 3.317135091730894999e-22 0.000000000000000000e+00 9.970982105030048195e-22 3.668886580653851401e-21 2.128413262810966185e-21 3.327398236952552529e-20 2.714000122819943499e+02 3.438985010829297557e-20 3.197069264637031954e-20 4.844710154708114690e-21 1.552873555218410735e-25 6.469167698611072805e-21 2.129780043302670699e-23 9.615588124715570619e-23 1.392426609190101735e-21 2.224708706303399872e-22 0.000000000000000000e+00 1.003594528248871989e-21 4.151382379820660545e-21 2.129766653901114118e-21 3.334998746400698962e-20 2.717000122684330563e+02 3.554776188947922169e-20 3.198472643895197567e-20 5.358544483041335117e-21 1.544882967344325376e-25 6.465787156653059380e-21 2.124313713814479274e-23 9.595460732653446804e-23 1.392376313068326913e-21 2.614037632330186042e-22 0.000000000000000000e+00 1.028219793444290543e-21 4.605362867880377876e-21 2.131106617469703976e-21 3.350176187480303508e-20 2.720000122549016623e+02 3.764461383318334420e-20 3.199876958055622192e-20 5.573070982795482068e-21 1.536892379469443574e-25 6.462416490231007901e-21 2.118859538915945330e-23 9.575333340589317597e-23 1.392326056275112102e-21 3.279537155320238520e-22 0.000000000000000000e+00 1.020191628874506888e-21 5.740414141395592427e-21 2.132446581038427370e-21 3.372446321003384940e-20 2.723000122414001680e+02 3.514866067199947164e-20 3.201282205887960991e-20 5.074888729479116397e-21 1.529079681723596604e-25 6.459045981451611908e-21 2.113417612710475662e-23 9.555205948523182996e-23 1.392277072961070253e-21 2.182047708764860815e-22 0.000000000000000000e+00 1.028488739843085657e-21 5.564457721224100317e-21 2.133786544607284299e-21 3.362832431538316680e-20 2.726000122279282891e+02 3.520342258848509644e-20 3.202688386163207652e-20 5.644142689540781763e-21 1.521279682073865566e-25 6.455679839625126481e-21 2.107988030060790287e-23 9.535078556455060634e-23 1.392263874319757301e-21 1.857048116571934500e-22 0.000000000000000000e+00 1.040971779664792741e-21 6.527799774542148687e-21 2.135126508176273637e-21 3.390413569546064950e-20 2.729000122144861393e+02 3.504484524465579338e-20 3.204095497653701001e-20 5.116346197022736238e-21 1.513488059629425543e-25 6.452313698607156977e-21 2.102570886593196541e-23 9.514951164384943458e-23 1.392250715715728899e-21 2.282187968088308988e-22 0.000000000000000000e+00 1.073453452983871172e-21 7.367097510386603185e-21 2.136466471745395382e-21 3.400622008864242291e-20 2.732000122010734344e+02 3.416613512276569997e-20 3.205503539133118387e-20 5.494940589339890416e-21 1.505813641367890076e-25 6.448958538459383019e-21 2.097166278701830849e-23 9.494823772312851452e-23 1.392227606018595744e-21 3.852072632561344506e-22 0.000000000000000000e+00 1.069414722040631871e-21 8.033076618338539171e-21 2.137806435314649159e-21 3.422935952881841643e-20 2.735000121876901744e+02 3.519414629441272033e-20 3.206912509376487717e-20 6.213049328791902222e-21 1.498139223105601328e-25 6.445628986910210612e-21 2.091774303552838195e-23 9.474696380238783440e-23 1.392179175721143472e-21 4.272310120310885585e-22 0.000000000000000000e+00 1.070101041434405470e-21 7.885177840449602291e-21 2.139146398884034215e-21 3.433080389628553911e-20 2.738500228227122193e+02 3.507697580389665877e-20 3.208557530291930592e-20 6.471992229113561944e-21 1.489226401399535105e-25 6.441744392392666675e-21 2.085499572299562030e-23 9.451213708253926299e-23 1.392122713078828915e-21 3.737309633183532199e-22 0.000000000000000000e+00 1.072254019429764982e-21 7.362133711322813654e-21 2.140709737286532208e-21 3.427662941966610739e-20 2.742000121565764630e+02 3.346586444099006792e-20 3.210203711599859399e-20 5.649820758214716210e-21 1.480403414471422824e-25 6.437860034586455179e-21 2.079242707167768770e-23 9.427732465391649914e-23 1.392099176783329228e-21 3.135757378832243625e-22 0.000000000000000000e+00 1.070495334074274422e-21 6.912771532666166799e-21 2.142272980546441119e-21 3.405105868971473742e-20 2.745000121432905758e+02 3.572062971633454255e-20 3.211615768893286216e-20 6.061146949823576016e-21 1.472840624108676484e-25 6.434530484333026621e-21 2.073893552911402873e-23 9.407605073311049680e-23 1.392087385644808447e-21 2.890217529737268575e-22 0.000000000000000000e+00 1.061051079409871792e-21 7.465313591975058324e-21 2.143608619340865650e-21 3.425012095198423534e-20 2.748000121300337355e+02 3.527586284757649520e-20 3.213028749657982590e-20 5.631898391791904411e-21 1.465352256863349638e-25 6.431201600251712109e-21 2.068557461471609933e-23 9.387477681228499300e-23 1.392069611067239609e-21 3.621846674543650283e-22 0.000000000000000000e+00 1.054687029483818094e-21 6.167002209248442046e-21 2.144928829612985856e-21 3.393018250346070178e-20 2.751000121168057149e+02 3.370154887390408848e-20 3.214442652676148112e-20 5.885074331794077015e-21 1.457901094401198599e-25 6.427876024566418404e-21 2.063234534200503526e-23 9.367350289144016408e-23 1.392021795161627067e-21 2.012104075435332445e-22 0.000000000000000000e+00 1.052728304128355041e-21 5.930079576784139588e-21 2.146249039885233204e-21 3.394235883331033198e-20 2.754000121036066275e+02 3.507647197806056468e-20 3.215857476731333530e-20 6.236942827234751083e-21 1.450449931938328947e-25 6.424550449422282425e-21 2.057924873247465692e-23 9.347222897057592774e-23 1.391974011788780264e-21 2.254974949752218293e-22 0.000000000000000000e+00 1.076806361716462039e-21 5.800128836036977849e-21 2.147569250157607693e-21 3.399645418077557379e-20 2.757000120904361893e+02 3.467718760160328780e-20 3.217273220608437743e-20 6.445227318757397051e-21 1.443144534636328418e-25 6.421253796380684091e-21 2.052628581562921741e-23 9.327095504969246032e-23 1.391926260952049264e-21 2.147130454192753140e-22 0.000000000000000000e+00 1.067244275345959952e-21 5.840731164857388818e-21 2.148889460430108195e-21 3.405468706561615833e-20 2.760000120772944001e+02 3.409657242347416787e-20 3.218689883093704794e-20 6.589862713785436904e-21 1.435875569437510970e-25 6.418000514882786924e-21 2.047345762902017788e-23 9.306968112878977357e-23 1.391878542654783191e-21 2.154005116738000574e-22 0.000000000000000000e+00 1.053618067268860979e-21 5.362584591651259372e-21 2.150209670702735086e-21 3.401613011671651975e-20 2.763000120641812032e+02 3.551815759944617953e-20 3.220107462974731690e-20 6.765023198303980884e-21 1.428606604238001082e-25 6.414747233916186121e-21 2.042076521828241860e-23 9.286840720786790275e-23 1.391830856900328162e-21 1.809502354111506332e-22 0.000000000000000000e+00 1.059194795809217961e-21 6.140892206380287855e-21 2.151529880975487614e-21 3.419450595468223005e-20 2.766500225917214948e+02 3.544453071509121897e-20 3.221762513911166507e-20 5.987299089037769558e-21 1.420154803483561360e-25 6.410890613134186358e-21 2.035946190725546276e-23 9.263358056013026738e-23 1.391804139723609146e-21 2.399770234164939854e-22 0.000000000000000000e+00 1.063357743251939919e-21 7.092324893627000096e-21 2.153070172689582156e-21 3.424899786764760243e-20 2.770000120336940768e+02 3.512112427379746248e-20 3.223418710213659237e-20 6.074778401413968872e-21 1.411706221140130387e-25 6.407006269553542680e-21 2.029835021167624815e-23 9.239876805897618720e-23 1.391790700820946174e-21 2.996470720941766516e-22 0.000000000000000000e+00 1.094940272293423410e-21 5.685978545429945738e-21 2.154610371612395674e-21 3.401768498105606864e-20 2.773000120206752968e+02 3.506051362364365968e-20 3.224839339341626502e-20 6.796591213501135804e-21 1.404564720792497744e-25 6.403695235759419109e-21 2.024611804348261807e-23 9.219749413799098074e-23 1.391770894410565122e-21 3.078833496220896885e-22 0.000000000000000000e+00 1.109918945001597339e-21 5.368044091132338050e-21 2.155930581885563481e-21 3.411592625208405121e-20 2.776000120076846542e+02 3.278173435603373397e-20 3.226260880627200922e-20 7.610951727758563482e-21 1.397596539276053244e-25 6.400444978592848658e-21 2.019402627649993027e-23 9.199622021698688409e-23 1.391723780203043282e-21 2.150909177297439290e-22 0.000000000000000000e+00 1.151597345418318709e-21 6.025386095319544345e-21 2.157250792158855420e-21 3.440996112236625240e-20 2.779000119947220924e+02 3.492692109410809185e-20 3.227683332865181281e-20 6.687874417393544449e-21 1.390628357758956253e-25 6.397194721920567375e-21 2.014207600005205523e-23 9.179494629596395602e-23 1.391676698560883921e-21 2.724818063481632661e-22 0.000000000000000000e+00 1.174307919407047490e-21 5.614238439937571533e-21 2.158565135473391051e-21 3.416172789036786841e-20 2.782000119817873838e+02 3.686012252053210236e-20 3.229106694851716917e-20 6.108982151336782477e-21 1.383667308559962206e-25 6.393927494552426891e-21 2.009026831175597612e-23 9.159367237492233759e-23 1.391645105470931958e-21 2.730838809030409713e-22 0.000000000000000000e+00 1.171866353444173246e-21 5.559715666095629384e-21 2.159879163114443780e-21 3.405706692283435062e-20 2.785000119688806421e+02 3.850885324045268987e-20 3.230530965384311942e-20 5.759339547182621573e-21 1.376715584721111921e-25 6.390638078206987910e-21 2.003860431755147585e-23 9.139239845386195826e-23 1.391633753750275232e-21 2.833838066559473509e-22 0.000000000000000000e+00 1.196108827441559938e-21 5.732550148732435775e-21 2.161193190755618761e-21 3.403869191759883331e-20 2.788500224134830887e+02 3.665941279288888059e-20 3.232193810748389913e-20 5.924941888108085676e-21 1.368604997866875489e-25 6.386800311765382325e-21 1.997851096520705633e-23 9.115757186176840511e-23 1.391620551583521373e-21 3.698492044901719824e-22 0.000000000000000000e+00 1.204251656524309067e-21 5.406677796123156267e-21 2.162726268817934295e-21 3.403007073805757553e-20 2.792000119388727057e+02 3.494022900722745284e-20 3.233857789783735701e-20 6.164137498107595631e-21 1.360646093926376973e-25 6.383037655783450022e-21 1.991862008308017826e-23 9.092275930464874501e-23 1.391571728577762923e-21 3.848512792024684296e-22 0.000000000000000000e+00 1.186570882730481974e-21 6.361569797588355705e-21 2.164259255252166546e-21 3.425168851661881678e-20 2.795000119260581641e+02 3.451465739102420391e-20 3.235285080135862612e-20 6.223788980890034023e-21 1.353868821488596390e-25 6.379823119619139203e-21 1.986744316395720435e-23 9.072148538352651118e-23 1.391524821463587464e-21 2.729554343671780209e-22 0.000000000000000000e+00 1.176491295449447187e-21 6.405216440886307052e-21 2.165573282893745521e-21 3.428213464002987115e-20 2.798000119132711347e+02 4.076593580497807821e-20 3.236713273838864322e-20 6.461421826760502021e-21 1.347091549050194310e-25 6.376608583939703066e-21 1.981641482818331637e-23 9.052021146238581033e-23 1.391477946933419329e-21 3.381765344171847624e-22 0.000000000000000000e+00 1.154455480465952208e-21 6.144952669025470015e-21 2.166887310535444866e-21 3.429125490559422180e-20 2.801000119005114470e+02 3.790961201103566570e-20 3.238142369697461763e-20 6.587118555983555770e-21 1.340416099120451322e-25 6.373394050278185606e-21 1.976553622654368589e-23 9.031893754122677177e-23 1.391431104990551782e-21 3.112350012554193777e-22 0.000000000000000000e+00 1.146418355922141886e-21 6.271284925268102647e-21 2.168201338177264205e-21 3.435044054867516838e-20 2.804000118877791010e+02 3.502228772992608123e-20 3.239572366517733046e-20 6.513310567698514468e-21 1.333747917585274813e-25 6.370179517205504676e-21 1.971480851830862883e-23 9.011766362004938374e-23 1.391384295638276209e-21 3.367195934616462817e-22 0.000000000000000000e+00 1.150828266072139210e-21 6.229132214494808508e-21 2.169515365819203163e-21 3.434205067285516155e-20 2.807500222617978807e+02 3.637428213300244296e-20 3.241241882837829486e-20 6.524748809846435782e-21 1.325981783979620393e-25 6.366408877325841771e-21 1.965581671506621756e-23 8.988283707531133756e-23 1.391349938136437872e-21 3.806226390857397635e-22 0.000000000000000000e+00 1.148095987639858756e-21 6.874016343828280160e-21 2.171048443572355784e-21 3.448247777211404569e-20 2.811000118581760034e+02 3.777856231514515370e-20 3.242912522808418947e-20 6.673872171660220562e-21 1.318297921477318883e-25 6.362617036221369905e-21 1.959703724914467248e-23 8.964802447056456076e-23 1.391337604030628342e-21 4.344361923325096210e-22 0.000000000000000000e+00 1.168468887445573604e-21 6.756449051847999857e-21 2.172563628221585736e-21 3.450419627212024576e-20 2.814000118455339816e+02 3.726586042971912778e-20 3.244345514228890514e-20 6.237902795643224534e-21 1.311711558118505043e-25 6.359366790747211929e-21 1.954682100079557076e-23 8.944675054932657600e-23 1.391327688144191406e-21 3.214596997725044090e-22 0.000000000000000000e+00 1.154408650805151246e-21 7.883755479834457734e-21 2.173857639413986788e-21 3.467261437450531173e-20 2.817000118329189604e+02 3.657986190435086478e-20 3.245779401453033216e-20 6.668805206382371551e-21 1.305168835425614240e-25 6.356149882396623061e-21 1.949676076789510772e-23 8.924547662807047687e-23 1.391284507842892826e-21 3.479292467991989396e-22 0.000000000000000000e+00 1.165951076780773597e-21 8.960640799294798787e-21 2.175151650606504450e-21 3.502614564702728994e-20 2.820000118203307125e+02 3.226605195468312392e-20 3.247214183294151614e-20 6.016663167050011295e-21 1.298691562970133420e-25 6.352935357281422739e-21 1.944685775529148842e-23 8.904420270679641618e-23 1.391238977395710578e-21 3.952682310097013334e-22 0.000000000000000000e+00 1.162313690501441805e-21 9.622666759226475757e-21 2.176445661799137592e-21 3.509677638850989075e-20 2.823500221356463840e+02 3.325637538273495593e-20 3.248889274012717765e-20 6.149124179004272948e-21 1.291134522071272258e-25 6.349196315115320778e-21 1.938883619303844263e-23 8.880937620144304962e-23 1.391196593261784230e-21 3.722215860905563130e-22 0.000000000000000000e+00 1.177285353586492165e-21 1.031639087878972113e-20 2.177955386081005424e-21 3.533117355320760986e-20 2.827000117910621384e+02 3.194203045009575599e-20 3.250565480000291717e-20 5.769528273455952663e-21 1.283711662102604301e-25 6.345490265227533798e-21 1.933103563718986468e-23 8.857456355708715607e-23 1.391185157000056592e-21 4.238695934787002271e-22 0.000000000000000000e+00 1.160579956852361412e-21 1.093556558907017527e-20 2.179465021249063680e-21 3.546797409327560255e-20 2.830000117785627936e+02 3.286443446411026856e-20 3.252003256168859598e-20 5.869688506680755187e-21 1.277401550005961808e-25 6.342313558371205097e-21 1.931948882486876398e-23 8.838921073404286862e-23 1.391175383209287102e-21 3.182940441720937724e-22 0.000000000000000000e+00 1.183304770234693675e-21 1.061304829886111143e-20 2.180759032442080127e-21 3.539870453193429389e-20 2.833000117660898809e+02 3.321240044200242391e-20 3.253441934917158124e-20 5.840485161061358395e-21 1.271091437908763251e-25 6.339159206125410651e-21 1.933417717065510701e-23 8.821398945789942019e-23 1.391143310243353725e-21 4.202214435621423105e-22 0.000000000000000000e+00 1.200280471140185440e-21 1.421813124375012814e-20 2.182053043635210926e-21 3.665053826084738365e-20 2.836000117536434004e+02 3.482573094676854364e-20 3.254881501775248305e-20 5.264642331744956717e-21 1.264848744710866919e-25 6.336017797547945159e-21 1.935150982331509144e-23 8.803876818174052577e-23 1.391098340288123846e-21 2.845866292997706819e-22 0.000000000000000000e+00 1.150690341900438334e-21 1.249185406554150363e-20 2.183347054828455325e-21 3.593673217691104715e-20 2.839500220109165980e+02 3.379830401004454823e-20 3.256562166684027945e-20 5.645785843083588588e-21 1.257581115998047912e-25 6.332352714696549738e-21 1.937506457741399329e-23 8.783433736009867850e-23 1.391045907030857214e-21 3.546819996784084198e-22 0.000000000000000000e+00 1.138490211256264928e-21 1.209962628270460951e-20 2.184856778859964301e-21 3.587524100043876814e-20 2.843000117247037224e+02 3.148685131655783898e-20 3.258243938257286415e-20 6.928957188933505361e-21 1.250332793944262253e-25 6.328647846805931778e-21 1.940219426247316626e-23 8.762991853731015103e-23 1.390993512638707901e-21 3.330807337084107758e-22 0.000000000000000000e+00 1.150153716585136391e-21 1.316420646080403791e-20 2.186357927905137116e-21 3.648466520208348092e-20 2.846000117123445534e+02 3.189186357527435168e-20 3.259686456982238596e-20 5.705102422659140994e-21 1.244197962736326333e-25 6.325471148130606663e-21 1.942828414930862403e-23 8.745469726110026366e-23 1.390948630329142738e-21 3.914409496679724781e-22 0.000000000000000000e+00 1.144605033614493532e-21 1.351403386764628465e-20 2.187639909804965935e-21 3.641340891791255522e-20 2.849000117000114756e+02 3.290402541484747782e-20 3.261129858722749072e-20 5.450349312794782291e-21 1.238063131527856619e-25 6.322315998357588624e-21 1.945698010836856188e-23 8.727947598487514188e-23 1.390914350878392196e-21 4.629539002145913917e-22 0.000000000000000000e+00 1.137476737150210603e-21 1.420653483390242718e-20 2.188921891704906097e-21 3.665027438456412129e-20 2.852000116877043183e+02 3.207435073528029704e-20 3.262574142306846742e-20 6.169258315611034978e-21 1.231965989507044222e-25 6.319211120090579260e-21 1.948827062754138424e-23 8.710425470863487974e-23 1.390904772098609025e-21 3.548059160471482112e-22 0.000000000000000000e+00 1.155273071679283153e-21 1.295468051936009189e-20 2.190203873604957225e-21 3.631053631205264804e-20 2.855500218875845349e+02 3.242009932111798882e-20 3.264260302036287368e-20 6.996144025858519106e-21 1.224996897527206738e-25 6.315588659441357323e-21 1.952803998404037153e-23 8.689982392051460487e-23 1.390893630385627533e-21 2.744701801321764115e-22 0.000000000000000000e+00 1.182644318556510655e-21 1.405796648983405963e-20 2.191699562803248606e-21 3.688114276412141142e-20 2.859000116590880225e+02 3.129606035912944300e-20 3.265947560155028122e-20 7.581767992440633150e-21 1.218028212299048435e-25 6.311939665459926886e-21 1.957129995856198169e-23 8.669540506401562657e-23 1.390855812594096354e-21 2.930087682794336606e-22 0.000000000000000000e+00 1.190342052206655397e-21 1.380085534695118844e-20 2.193195164705505471e-21 3.691454991615995255e-20 2.862000116468667557e+02 3.021823693480672003e-20 3.267394774770973115e-20 6.914922153906824571e-21 1.212100215648218436e-25 6.308799910208673277e-21 1.961114367892068634e-23 8.652018378772519433e-23 1.390811481164901468e-21 2.615851505619919822e-22 0.000000000000000000e+00 1.201029412355617142e-21 1.432586391952624953e-20 2.194477146605923730e-21 3.699598895123355647e-20 2.865000116346710684e+02 3.077327477262832714e-20 3.268842866167674830e-20 6.204003067002508112e-21 1.206206882554462871e-25 6.305660157589092346e-21 1.965352125921245455e-23 8.634496251141983331e-23 1.390767176052135449e-21 3.428088715500035890e-22 0.000000000000000000e+00 1.184474361354372109e-21 1.575776571854806862e-20 2.195759128506451075e-21 3.746165350782160252e-20 2.868500217883903360e+02 3.048331306609527413e-20 3.270533461859846529e-20 6.164868910864237807e-21 1.199331127534733509e-25 6.302034218530536825e-21 1.970614400223832058e-23 8.614053175026082618e-23 1.390715518518157462e-21 3.336971470339360875e-22 0.000000000000000000e+00 1.164715478423482071e-21 1.698885551079733740e-20 2.197254817507483971e-21 3.800288292901927782e-20 2.872000116063135806e+02 3.083566197951025208e-20 3.272225149256234361e-20 6.290979959971219214e-21 1.192539775611272102e-25 6.298411977034609826e-21 1.976216278937122227e-23 8.593611286664941157e-23 1.390663899811476158e-21 2.373731785911703389e-22 0.000000000000000000e+00 1.143510592087869121e-21 1.755611214848839902e-20 2.198750419608105226e-21 3.829294225265152786e-20 2.875000115942026468e+02 3.023393150169997380e-20 3.273676154851225822e-20 6.717709163637984052e-21 1.186739775845416680e-25 6.295307108741543264e-21 1.981286392265004277e-23 8.576089159029453872e-23 1.390632459467452015e-21 2.765279496022920888e-22 0.000000000000000000e+00 1.145444651513162203e-21 1.865558341588113517e-20 2.200041103254648061e-21 3.889286766768117822e-20 2.878000115821170084e+02 3.162872630814202998e-20 3.275128032189671134e-20 6.661468073975750843e-21 1.180939776079072234e-25 6.292202240863260321e-21 1.986602231663854110e-23 8.558567031392490167e-23 1.390623111509558484e-21 3.078833519595352376e-22 0.000000000000000000e+00 1.130402287195021650e-21 2.171238493766191587e-20 2.201345069917540604e-21 4.044998222705871831e-20 2.881500216900911369e+02 3.650093904186785772e-20 3.276823038360952355e-20 6.038807939713968178e-21 1.174325305272568432e-25 6.288579796764445139e-21 1.993112179699820330e-23 8.538123957948429339e-23 1.390612239110320484e-21 3.470676122445851527e-22 0.000000000000000000e+00 1.125944007659050753e-21 2.122578013483029618e-20 2.202866408353740842e-21 4.010593993246437693e-20 2.885000115540148045e+02 3.048890877627819715e-20 3.278519129585891016e-20 6.231894496342562430e-21 1.167725496410007882e-25 6.284957563279526811e-21 1.999950282194968517e-23 8.517682066900538023e-23 1.390572366178051665e-21 2.887886016646440648e-22 0.000000000000000000e+00 1.134258577530652060e-21 2.348242397859138130e-20 2.204387658798047386e-21 4.138599784612757375e-20 2.888000115420127258e+02 2.974735439211604429e-20 3.279973904374178351e-20 6.581479163008965620e-21 1.162071783010162216e-25 6.281852702241013290e-21 2.006070627385952756e-23 8.500159939258692489e-23 1.390528263567419105e-21 2.141426110794705148e-22 0.000000000000000000e+00 1.144249110177159044e-21 2.741344481149125966e-20 2.205691625461303298e-21 4.379793162143369112e-20 2.891000115300354878e+02 2.974021821035109832e-20 3.281429545894153293e-20 6.102178940234816444e-21 1.156431783235334217e-25 6.278747841146588368e-21 2.012427704169674259e-23 8.482637811615396396e-23 1.390484187293124714e-21 3.629495123742161172e-22 0.000000000000000000e+00 1.148587777022320556e-21 2.544397824197665774e-20 2.206995592124666791e-21 4.253347082098277025e-20 2.894500215926750002e+02 2.955780309638541068e-20 3.283128937190022382e-20 6.717238866065820854e-21 1.149851594057711322e-25 6.275165845431443627e-21 2.020140736611257411e-23 8.462194740819200069e-23 1.390473077179753396e-21 1.856635116093891592e-22 0.000000000000000000e+00 1.166079795942742847e-21 3.151508659517589855e-20 2.208516930363817688e-21 4.651672810633307325e-20 2.898000115021852139e+02 3.083206685082682248e-20 3.284829406923519135e-20 7.051464683151526193e-21 1.143354075388614415e-25 6.271585245405462734e-21 2.028168846779674145e-23 8.441752847108729413e-23 1.390463354535777733e-21 3.198728025167254208e-22 0.000000000000000000e+00 1.170151282524559065e-21 3.030154754464225858e-20 2.210038181006268945e-21 4.576622018412659698e-20 2.901000114902904556e+02 3.064484989443487827e-20 3.286287929230016888e-20 6.414187403229719440e-21 1.137868361320404751e-25 6.268516072574954483e-21 2.035298588814860729e-23 8.424230719460617320e-23 1.390441265553397467e-21 2.615250525346174887e-22 0.000000000000000000e+00 1.153263702677065016e-21 3.480387502249891002e-20 2.211342147669990917e-21 4.878466900891335722e-20 2.904500215183328464e+02 2.998738988110500463e-20 3.287990676526674815e-20 6.227826222229587742e-21 1.131468177950486679e-25 6.264935268703166957e-21 2.043903199560982916e-23 8.403787650685136925e-23 1.390391411817350951e-21 3.469889517690081182e-22 0.000000000000000000e+00 1.165495979784345955e-21 2.872797713432810054e-20 2.212863485758763172e-21 4.464007602957420390e-20 2.908000114626316304e+02 3.019483693944825260e-20 3.289694497195198309e-20 5.982046484000880347e-21 1.125172403863410350e-25 6.261354677749352794e-21 2.052811962606842534e-23 8.383345754942767859e-23 1.390341590478483578e-21 2.898692238584572977e-22 0.000000000000000000e+00 1.176507119838204760e-21 3.337614934722222323e-20 2.214379328765149139e-21 4.774387860718740268e-20 2.911000114508184993e+02 3.170200847746221471e-20 3.291155887528216785e-20 6.013605754488980192e-21 1.119811534509288654e-25 6.258314251247462484e-21 2.060687749404035208e-23 8.365823627289886785e-23 1.390298908759874613e-21 4.557533806484167619e-22 0.000000000000000000e+00 1.170998553254579098e-21 4.186522642835547505e-20 2.215664791186057239e-21 5.403356657274403849e-20 2.914000114390297540e+02 3.128831108645946025e-20 3.292618135788522090e-20 6.509354471345721509e-21 1.114450665154731200e-25 6.255279570877953692e-21 2.068781940879196303e-23 8.348301499635582187e-23 1.390256248746537687e-21 2.247645591753226502e-22 0.000000000000000000e+00 1.186037217097349099e-21 4.149004873006243461e-20 2.216950253607069912e-21 5.380864300688513712e-20 2.917500214224499473e+02 3.144348762000394934e-20 3.294325223668081894e-20 6.507662520766588573e-21 1.108215003248694891e-25 6.251739046303072175e-21 2.078498077302943093e-23 8.327858433466356145e-23 1.390209951736552646e-21 3.080891604550132050e-22 0.000000000000000000e+00 1.201526113114358784e-21 4.272479111801410509e-20 2.218450002601556612e-21 5.477681728615057543e-20 2.921000114116168334e+02 3.167588560104928470e-20 3.296033378364560764e-20 5.471230183472856803e-21 1.101984412232756979e-25 6.248199141750062461e-21 2.088503346718639358e-23 8.307416535103370537e-23 1.390200425464456998e-21 2.661001561330543796e-22 0.000000000000000000e+00 1.216807964710291002e-21 4.508717325825891445e-20 2.219949665923169012e-21 5.653875440754849452e-20 2.924000113999085784e+02 3.252021051540226293e-20 3.297498478138695765e-20 5.444156379622985779e-21 1.096653715775496686e-25 6.245164851873960102e-21 2.097306968414592906e-23 8.289894407444365137e-23 1.390192283810958827e-21 3.654027607947949878e-22 0.000000000000000000e+00 1.208726537217852423e-21 4.601977916607937893e-20 2.221235128344526621e-21 5.729117724185482386e-20 2.927500213492733678e+02 3.465861691731249269e-20 3.299208887911664677e-20 6.212317949216232114e-21 1.090597021869097222e-25 6.241641799169805537e-21 2.107839810991504753e-23 8.269451343264215420e-23 1.390165783198915067e-21 2.299240169589448814e-22 0.000000000000000000e+00 1.216510680812711861e-21 4.305572414325871214e-20 2.222734877193090275e-21 5.502942352943294126e-20 2.931000113726826157e+02 4.018098991166184040e-20 3.300920359482772415e-20 6.058485583965937687e-21 1.084540672768363443e-25 6.238141672054924320e-21 2.118649813389157216e-23 8.249009442901234319e-23 1.390116613366606761e-21 4.100608367363208092e-22 0.000000000000000000e+00 1.217197662669640797e-21 4.847385506671757823e-20 2.224234540661426939e-21 5.935889506309300766e-20 2.934000113610541121e+02 3.823226379240775567e-20 3.302388298126594758e-20 6.381524905842663815e-21 1.079371110221990023e-25 6.235141478883730916e-21 2.128133664604610022e-23 8.231487315237569260e-23 1.390074490127502331e-21 2.683011777594873947e-22 0.000000000000000000e+00 1.193398151190674289e-21 3.444384151378015031e-20 2.225520003083126100e-21 4.863069580480109806e-20 2.937500212765950209e+02 3.894162675769109952e-20 3.304102015060645095e-20 6.591881706720482077e-21 1.073390506012964961e-25 6.231641156523372758e-21 2.139448913462444613e-23 8.211044253032974157e-23 1.390025372411836332e-21 3.060279223267685738e-22 0.000000000000000000e+00 1.184438312484064721e-21 3.110622863065064726e-20 2.227019751786758635e-21 4.636796591107641211e-20 2.941000113340131747e+02 3.850791024038441653e-20 3.305816788794468875e-20 6.133720181810605538e-21 1.067410241118820273e-25 6.228141033238998434e-21 2.151029150920439465e-23 8.190602350683632123e-23 1.389976287053317215e-21 2.376670848198301998e-22 0.000000000000000000e+00 1.171726333731543663e-21 3.497404340038392149e-20 2.228518403459052961e-21 4.899768737171536434e-20 2.944000113224635697e+02 3.725609741635425138e-20 3.307287553714198069e-20 5.888193805731451826e-21 1.062363682503511338e-25 6.225140843913521503e-21 2.161163539139444184e-23 8.173080223015359126e-23 1.389938778268254492e-21 3.048854539201580447e-22 0.000000000000000000e+00 1.162501825869830453e-21 2.747666681244698889e-20 2.229786994819983305e-21 4.393814871749597303e-20 2.947500212044097907e+02 3.673653857051519274e-20 3.309004563135750835e-20 5.965719875093553666e-21 1.056537711565309316e-25 6.221640525350483305e-21 2.173226451825285800e-23 8.152637162772932107e-23 1.389929478030897582e-21 3.336745802618543823e-22 0.000000000000000000e+00 1.145400169292260487e-21 2.457213349267800998e-20 2.231267059918554505e-21 4.220640170037880474e-20 2.951000112956057819e+02 3.699425840257893408e-20 3.310722624379124712e-20 6.684074802126449791e-21 1.050712070047336980e-25 6.218140405181673815e-21 2.185542119994577674e-23 8.132195258450723815e-23 1.389920208426319344e-21 3.670480895247977217e-22 0.000000000000000000e+00 1.131336565273934042e-21 2.122900555230938886e-20 2.232747041329206587e-21 4.047764824625179474e-20 2.954000112841342798e+02 3.761975277583275013e-20 3.312196203031328291e-20 6.957194485833252118e-21 1.045772287718741108e-25 6.215158199900582651e-21 2.196297194192050600e-23 8.114673130777889899e-23 1.389894326262217816e-21 3.785884494263283661e-22 0.000000000000000000e+00 1.156443741127877540e-21 1.844818287187692615e-20 2.234015632690467198e-21 3.915151283381035029e-20 2.957500211327127317e+02 3.416287607722746488e-20 3.313916490325540537e-20 7.106238041041432448e-21 1.040021588271129708e-25 6.211697214585406214e-21 2.209072959775039423e-23 8.094230072484377266e-23 1.389845824685326050e-21 3.348947970491660334e-22 0.000000000000000000e+00 1.155566477715227875e-21 1.982256212593741252e-20 2.235495697647938451e-21 3.985731628711020625e-20 2.961000112574578793e+02 3.594871282834964719e-20 3.315637824484023783e-20 6.169829995087918310e-21 1.034276377083693394e-25 6.208236424790858913e-21 2.222089305645729492e-23 8.073788166202661033e-23 1.389797355433668282e-21 3.606623893710095730e-22 0.000000000000000000e+00 1.155017019849293467e-21 1.811786658819804870e-20 2.236975679200457843e-21 3.889239335185119023e-20 2.964000112460636842e+02 3.424416050295693544e-20 3.317114222492805980e-20 5.417480434872454379e-21 1.029424764364734867e-25 6.205269950750275253e-21 2.218319604925854875e-23 8.057845943791667822e-23 1.389755832745688288e-21 3.932821197428376907e-22 0.000000000000000000e+00 1.152818786289187910e-21 1.797052625958694821e-20 2.238244270562045336e-21 3.872403343711517563e-20 2.967500210614988418e+02 3.563213560978959909e-20 3.318837803285378690e-20 6.013955641667971910e-21 1.023764390575331814e-25 6.201808967602691591e-21 2.206280929044251829e-23 8.040049011137806705e-23 1.389707415735108589e-21 2.890778348897290050e-22 0.000000000000000000e+00 1.162563245089408575e-21 1.896192126179308691e-20 2.239724335379365312e-21 3.929430891911424813e-20 2.971000112195667384e+02 3.620977385379221850e-20 3.320562425800765237e-20 6.200651923398499354e-21 1.018123691937237414e-25 6.198357169530533452e-21 2.194255712054403125e-23 8.022253078001176755e-23 1.389668012219333200e-21 3.936692289141864060e-22 0.000000000000000000e+00 1.163193502631933513e-21 1.937908227375444851e-20 2.241204317072794316e-21 3.954110663240446555e-20 2.974000112082490546e+02 3.301718243187571853e-20 3.322041620023632441e-20 6.468125263331305186e-21 1.013336595343640039e-25 6.195424405171674138e-21 2.183958427990626117e-23 8.006998992660454967e-23 1.389660236944151460e-21 3.332281012860522558e-22 0.000000000000000000e+00 1.186784420446406992e-21 1.647350536287436841e-20 2.242472908434705304e-21 3.825805256633198677e-20 2.977500209907633462e+02 3.592851238368770915e-20 3.323768449057149888e-20 5.935861074308549621e-21 1.007751493007605762e-25 6.192002751412666986e-21 2.171956841551253654e-23 7.989202061680518964e-23 1.389651493904213727e-21 3.763448469913143218e-22 0.000000000000000000e+00 1.207278795657363852e-21 1.667064216674151251e-20 2.243949258196674987e-21 3.827272889251887867e-20 2.981000111819297445e+02 3.627678693521140752e-20 3.325496314897554619e-20 5.019605197825358173e-21 1.002234719940241496e-25 6.188559943000281957e-21 2.159969325324715382e-23 7.971406126860930225e-23 1.389622063524681170e-21 4.967769368862842427e-22 0.000000000000000000e+00 1.204593560555517523e-21 1.526000840860642059e-20 2.245424225169422785e-21 3.756238510092945169e-20 2.984500209415305676e+02 3.493049988112526339e-20 3.327225409106554338e-20 5.427562891767933864e-21 9.967983981421861301e-26 6.185098969798512740e-21 2.147994762390449301e-23 7.953609197046076043e-23 1.389574696674202618e-21 3.191425266150799831e-22 0.000000000000000000e+00 1.214680675423379386e-21 1.859687742493697007e-20 2.246899274609609087e-21 3.910452906173770621e-20 2.988000111557338414e+02 3.522865111597683478e-20 3.328955536693411546e-20 5.430506904180780463e-21 9.913623799215822931e-26 6.181638192755435505e-21 2.136034720013785454e-23 7.935813261055131870e-23 1.389527356350616075e-21 3.148010661564080633e-22 0.000000000000000000e+00 1.233289485381418149e-21 1.722484768939544013e-20 2.248374241679441434e-21 3.848643605339033312e-20 2.991000111445445100e+02 3.587916879018588448e-20 3.330439442617655384e-20 6.293594880642438982e-21 9.867496165091068836e-26 6.178738018893673282e-21 2.125794171205452599e-23 7.920559175707883737e-23 1.389487170960308592e-21 2.385567477728915852e-22 0.000000000000000000e+00 1.239321975313567452e-21 1.644781800686405989e-20 2.249638534469607305e-21 3.828956316229080483e-20 2.994500208715972462e+02 1.279672114537330735e-19 3.332171760560510835e-20 7.837372552693991283e-21 9.813877653712776985e-26 6.175354388686227843e-21 2.113859812991205638e-23 7.902762247547999824e-23 1.389440308873809302e-21 2.526782240557491051e-21 0.000000000000000000e+00 1.255083636096115085e-21 1.564617544241385959e-20 2.251113583772625641e-21 3.833619298909208545e-20 2.998000111185232868e+02 1.284091381454413359e-19 3.333905106999909796e-20 1.541501201855277234e-20 9.760262126524104535e-26 6.171959834955334174e-21 2.101940652816383100e-23 7.884966309893203347e-23 1.389404575187828515e-21 3.943563048830154053e-21 0.000000000000000000e+00 1.255050922364155338e-21 1.209588061324401862e-20 2.252588550980362094e-21 3.946715646559837196e-20 3.001500208229211353e+02 6.347099349933215463e-20 3.335639673022572681e-20 1.429237919423060956e-20 9.707486224972736517e-26 6.168515683978436015e-21 2.090035613308370242e-23 7.867169382885251000e-23 1.389396614605317986e-21 7.203000782458161253e-22 0.000000000000000000e+00 1.256498885095146586e-21 1.318287104091170851e-20 2.254063600187905839e-21 3.921575517400807925e-20 3.005000110926231969e+02 3.513089901632002246e-20 3.337375264136965443e-20 7.952912719467749828e-21 9.654764286472932573e-26 6.165080557194543148e-21 2.078146271368688456e-23 7.849373444072363366e-23 1.389388678791129826e-21 3.452294029354367076e-22 0.000000000000000000e+00 1.243516735037843321e-21 1.662561233229358894e-20 2.255538567491627331e-21 3.873196813069582049e-20 3.008000110815601147e+02 3.460957806932255051e-20 3.338863846200869076e-20 6.462744607453273789e-21 9.609640902746366052e-26 6.162166559544918896e-21 2.067967288510924139e-23 7.834119358718695859e-23 1.389359692889150874e-21 2.741348596007854242e-22 0.000000000000000000e+00 1.234729466453546965e-21 1.790350988582184572e-20 2.256802860282325090e-21 3.903467638434940344e-20 3.011500207537764595e+02 3.428747081744395243e-20 3.340601611619648118e-20 6.151282397741552086e-21 9.557511802629038435e-26 6.158783132713494619e-21 2.056105906965546035e-23 7.816322433347075141e-23 1.389312947389165141e-21 3.472074433362263816e-22 0.000000000000000000e+00 1.238587768017136745e-21 1.479445868503027018e-20 2.258265590403909220e-21 3.767357089814430534e-20 3.015000110558317488e+02 3.656200587751429448e-20 3.342340397283412293e-20 6.451126645860709018e-21 9.505385587429314712e-26 6.155399894301388769e-21 2.044260975136486910e-23 7.798526492889123130e-23 1.389266228379523699e-21 3.943842382274619591e-22 0.000000000000000000e+00 1.259882557506665313e-21 1.570768564749543378e-20 2.259720125808454557e-21 3.810704715257722647e-20 3.018500207056478075e+02 3.546585395330960080e-20 3.344080393804803531e-20 6.410198842120555985e-21 9.453870685160906049e-26 6.152053648198751968e-21 2.032431458821806521e-23 7.780729568656489436e-23 1.389219957642421197e-21 6.101127946883751370e-22 0.000000000000000000e+00 1.278596067740472846e-21 1.659139682117749053e-20 2.261174741620950854e-21 3.849099356574327355e-20 3.022000110302226403e+02 1.257848976723637161e-19 3.345821407190548729e-20 5.453890050840975652e-21 9.403177349727751411e-26 6.148707586853915018e-21 2.020618947301313555e-23 7.762933627053488377e-23 1.389173713359548038e-21 2.566439341166143980e-21 0.000000000000000000e+00 1.264341348532948561e-21 1.579097832070697734e-20 2.262629277119085478e-21 3.809986228693792545e-20 3.025000110192835336e+02 3.657637674440145486e-20 3.347314630078987176e-20 5.799083363058522116e-21 9.359724719733246426e-26 6.145829893480259242e-21 2.010506891125659955e-23 7.747679541693516694e-23 1.389143975795610853e-21 3.624907204559261613e-22 0.000000000000000000e+00 1.258135726028666210e-21 1.563388000369936493e-20 2.263876056252363801e-21 3.801375919141546294e-20 3.028500206372784760e+02 3.456099629650087036e-20 3.349057801827901595e-20 6.140607977732514074e-21 9.309449685878987844e-26 6.142446467172974543e-21 1.998724867664853933e-23 7.729882619078888672e-23 1.389136201778117038e-21 3.030503512921914359e-22 0.000000000000000000e+00 1.242006784723615575e-21 1.547553535879427115e-20 2.265330671932613786e-21 3.801644306079037886e-20 3.032000109938432502e+02 1.313004371936644042e-19 3.350801985628948730e-20 5.434856275924038180e-21 9.259493167615639543e-26 6.139063227059515722e-21 1.986960685536340955e-23 7.712086675849297306e-23 1.389128452521414152e-21 2.111195289992956631e-21 0.000000000000000000e+00 1.228570450721513582e-21 2.780642772681131615e-20 2.266785207563696633e-21 4.445504970236008147e-20 3.035500205896880175e+02 6.119233875603491334e-20 3.352547371621606234e-20 4.930128839225797090e-21 9.209533903198219618e-26 6.135731673548003943e-21 1.975213357845870406e-23 7.694289754360938633e-23 1.389094374463434527e-21 9.243066897509110224e-22 0.000000000000000000e+00 1.226649779421559744e-21 1.564877073824906272e-20 2.268239823151891681e-21 3.795042298888690996e-20 3.039000109685201778e+02 3.620115582504692747e-20 3.354293766309908016e-20 5.713578706169302718e-21 9.160523468977396163e-26 6.132424072165633260e-21 1.963484489392425675e-23 7.676493809999116986e-23 1.389048246833503896e-21 3.706952114068534060e-22 0.000000000000000000e+00 1.222744342050496993e-21 1.391313940270777102e-20 2.269694358875516590e-21 3.738549834245846510e-20 3.042500205423165198e+02 3.688319089639370259e-20 3.356041359638773081e-20 6.038518911288044048e-21 9.111667965968322478e-26 6.129116110088963691e-21 1.951773114098358148e-23 7.658696889631854312e-23 1.389002176413965118e-21 3.861849408872325812e-22 0.000000000000000000e+00 1.238018646637848809e-21 1.378048629379470869e-20 2.271148974372079878e-21 3.740332148872351975e-20 3.046000109433134639e+02 3.531951776296187163e-20 3.357789958316725765e-20 6.661649861363916943e-21 9.062857431431526843e-26 6.125806418253448919e-21 1.940080844170505234e-23 7.640900944143021578e-23 1.388956514295443149e-21 2.464223718873226345e-22 0.000000000000000000e+00 1.255079063529996426e-21 1.343020148284188047e-20 2.272594411021974883e-21 3.739632044960188977e-20 3.049000109325460244e+02 3.523638998080094318e-20 3.359289673312926737e-20 7.083999421752001552e-21 9.021299538186258313e-26 6.122969461833532238e-21 1.930073574291144455e-23 7.625646858774321849e-23 1.388917393304048597e-21 5.321242111964271301e-22 0.000000000000000000e+00 1.259119986299105698e-21 1.264246679867451117e-20 2.273825392055311292e-21 3.721508539351697356e-20 3.052500204750198236e+02 3.447717555579318780e-20 3.361040408036458512e-20 5.656869078490134922e-21 8.972814005776202620e-26 6.119660246060252091e-21 1.918415853648963554e-23 7.607849939999714137e-23 1.388883721672329901e-21 3.277914081868486250e-22 0.000000000000000000e+00 1.263667307510753806e-21 1.253339858498331621e-20 2.275261575801097670e-21 3.694606911856652245e-20 3.056000109075041564e+02 3.376561390548609510e-20 3.362792143345493614e-20 5.468116563571128755e-21 8.924611022942146817e-26 6.116352644170839725e-21 1.906778213345697444e-23 7.590053992909842816e-23 1.388876138188645601e-21 2.825058188586356933e-22 0.000000000000000000e+00 1.254603704446982504e-21 1.149988832047333996e-20 2.276697681133432908e-21 3.659462929816730395e-20 3.059500204281739002e+02 3.250365725161768617e-20 3.364545068713109650e-20 6.000009213697879972e-21 8.877213900351454295e-26 6.113044861887586904e-21 1.895159741470242392e-23 7.572257075243904952e-23 1.388868578632329367e-21 4.973068186617766686e-22 0.000000000000000000e+00 1.252019775052632378e-21 1.203255705136688080e-20 2.278133864789751189e-21 3.686608223943452747e-20 3.063000108825768280e+02 3.151409533995645220e-20 3.366298991343757915e-20 6.449969050284238794e-21 8.829819359651059958e-26 6.109735766653893275e-21 1.883562070976064156e-23 7.554461127039541559e-23 1.388833891449878005e-21 5.463314995447225622e-22 0.000000000000000000e+00 1.250617033658926841e-21 1.032164472069059697e-20 2.279569970212024346e-21 3.643704287145727975e-20 3.066500203815418217e+02 3.123793116265548108e-20 3.368054100516505655e-20 6.428582930430779272e-21 8.783044733157373534e-26 6.106425894218028705e-21 1.871984313867523897e-23 7.536664210477223620e-23 1.388788965314166624e-21 4.672572997353365656e-22 0.000000000000000000e+00 1.256338512130193444e-21 9.869201584636970442e-21 2.281006153779282285e-21 3.632257656457987639e-20 3.070000108577631295e+02 3.086509067548272666e-20 3.369810203639718017e-20 5.670426822728217502e-21 8.736860422893116366e-26 6.103119463720910165e-21 1.860428112872753425e-23 7.518868261163461572e-23 1.388744157364501955e-21 4.493775547323882344e-22 0.000000000000000000e+00 1.258006412345490285e-21 1.010001074435008364e-20 2.282442259291081845e-21 3.627537426710441420e-20 3.073500203351221671e+02 3.063176758921084220e-20 3.371567489798612585e-20 6.618232877340560348e-21 8.690673605262231590e-26 6.099847635997771600e-21 1.848892604929407025e-23 7.501071345699741845e-23 1.388699366662289997e-21 4.937949054592478251e-22 0.000000000000000000e+00 1.265991860729929476e-21 9.257435713874616195e-21 2.283878442769684939e-21 3.622779487288444957e-20 3.077000108330623789e+02 3.187595205375103409e-20 3.373325766605300441e-20 6.876185060043565514e-21 8.644565240313454750e-26 6.096575985690938400e-21 1.837379443319607101e-23 7.483275395281639295e-23 1.388654598069806650e-21 4.651165757880423794e-22 0.000000000000000000e+00 1.291948978668637083e-21 8.977721189481294468e-21 2.285314548370603146e-21 3.622188202681915216e-20 3.080500202889135153e+02 3.418901535700473956e-20 3.375085222951312003e-20 6.723772396850754953e-21 8.598480661959720579e-26 6.093320242489616857e-21 1.825887790988465748e-23 7.465478480911530158e-23 1.388627226126455040e-21 7.315625883225902396e-22 0.000000000000000000e+00 1.293766917743173593e-21 1.078764091477749339e-20 2.286749569533486214e-21 3.670426844527336719e-20 3.084000108084737235e+02 3.704205069726409008e-20 3.376845666652332158e-20 6.211436819034431070e-21 8.552398613841101265e-26 6.090083771018414776e-21 1.814419312595354019e-23 7.447682529394117046e-23 1.388620508731730948e-21 6.835578377546161508e-22 0.000000000000000000e+00 1.305298087363634192e-21 9.926519013949723248e-21 2.288181354745937799e-21 3.638483866019636353e-20 3.087500202429143314e+02 3.709284867825036314e-20 3.378607286406370273e-20 5.298799614591853428e-21 8.507510805960265341e-26 6.086847124635415970e-21 1.802973198226132391e-23 7.429885616112667316e-23 1.388613811026470653e-21 7.197624473865813595e-22 0.000000000000000000e+00 1.320867566560498021e-21 1.131247840720579628e-20 2.289613217337759459e-21 3.666111078612241854e-20 3.091000107839963675e+02 3.759258297359939739e-20 3.380369890232511103e-20 5.491385832391699737e-21 8.462625421103973456e-26 6.083582507888729447e-21 1.791551124786734790e-23 7.412089663500934792e-23 1.388576722046733104e-21 8.044350784011898487e-22 0.000000000000000000e+00 1.308430126535226130e-21 1.065908028947615920e-20 2.291045002638255382e-21 3.651045465583208742e-20 3.094500201971233082e+02 3.909525987868874968e-20 3.382133666635405464e-20 6.210852166530103476e-21 8.418005640685827354e-26 6.080310680766021358e-21 1.780152310699039180e-23 7.394292751303221499e-23 1.388532049953203215e-21 8.221145549678612407e-22 0.000000000000000000e+00 1.305237879771224515e-21 9.521878251137588041e-21 2.292476865142884701e-21 3.632716085920511990e-20 3.098000107596297426e+02 3.814848840599758052e-20 3.383898423837365850e-20 6.216523504043813061e-21 8.374292533695228214e-26 6.077045061792671520e-21 1.768778446033038032e-23 7.376496797602123095e-23 1.388487470040090937e-21 9.118815353092119149e-22 0.000000000000000000e+00 1.311396284405710241e-21 1.186021155624497037e-20 2.293908650531025860e-21 3.702788233532993218e-20 3.101500201515389676e+02 3.954022813609038931e-20 3.385664350149850637e-20 6.604138827376364886e-21 8.330577074950648464e-26 6.073808415802973188e-21 1.757428778806760856e-23 7.358699886483265587e-23 1.388443246095785740e-21 1.088921886980298234e-21 0.000000000000000000e+00 1.289574373403420987e-21 8.559941875586142579e-21 2.295340512948855172e-21 3.619532500187757397e-20 3.105000107353728822e+02 4.033216934347332347e-20 3.387431273927749787e-20 6.162824868984146650e-21 8.286918250687587942e-26 6.070571943737411823e-21 1.744095478743155588e-23 7.342892563240801627e-23 1.388399044226491635e-21 1.166012312873259886e-21 0.000000000000000000e+00 1.291532189376839098e-21 9.090217022457913528e-21 2.296772298424245471e-21 3.626526594651278701e-20 3.108500201061598887e+02 4.114322702518487060e-20 3.389199366377036034e-20 5.181454499711906172e-21 8.243329454820502229e-26 6.067372158614511641e-21 1.730513854308938330e-23 7.327399263023208736e-23 1.388374201709755821e-21 1.271933692825480858e-21 0.000000000000000000e+00 1.269316641801664710e-21 1.088273049703875376e-20 2.298204160755665227e-21 3.662247270621061503e-20 3.112000107112252181e+02 4.096232127677418639e-20 3.390968432958063189e-20 5.735065318564656923e-21 8.199742995962881052e-26 6.064207349951687103e-21 1.717008507339079756e-23 7.311906793477546799e-23 1.388367643788998891e-21 1.192986753130387546e-21 0.000000000000000000e+00 1.251276958446943749e-21 8.724942008888039201e-21 2.299635946317911957e-21 3.613678641243738682e-20 3.115500200609847639e+02 4.105138036232623279e-20 3.392738661599063878e-20 5.282797503381286659e-21 8.156915935464296409e-26 6.061042371788968104e-21 1.703579787325803560e-23 7.296413494190743248e-23 1.388361105574683658e-21 1.502263857363854463e-21 0.000000000000000000e+00 1.258040871999007590e-21 1.216700250900952670e-20 2.301066446691856216e-21 3.707850088142551957e-20 3.119000106871858975e+02 4.075545362501239642e-20 3.394509861128761533e-20 5.300798692735382064e-21 8.114488500369711270e-26 6.057818180742152030e-21 1.690230975268792456e-23 7.280921023709495954e-23 1.388323427509860831e-21 1.558689783497011284e-21 0.000000000000000000e+00 1.246726980262399946e-21 1.019171168612783522e-20 2.302478854832201529e-21 3.649869332471506084e-20 3.122500200160121722e+02 4.150249667801537959e-20 3.396282219282662774e-20 5.371934028073223596e-21 8.072058798058933977e-26 6.054581535335801327e-21 1.676962534952109154e-23 7.265427725349311090e-23 1.388279322268286844e-21 1.604158108796361972e-21 0.000000000000000000e+00 1.248041108590418850e-21 8.791327922009037411e-21 2.303891338448110716e-21 3.616141721776773264e-20 3.126000106632542384e+02 4.301720177407279142e-20 3.398055545092047106e-20 6.369246512280893779e-21 8.030121173741432848e-26 6.051357350385466839e-21 1.663777823335654742e-23 7.249935253936679655e-23 1.388235307684153403e-21 1.763789178562378892e-21 0.000000000000000000e+00 1.239903328395236249e-21 1.063930948917965357e-20 2.305303746673368098e-21 3.683686672639563132e-20 3.129500199712407493e+02 4.185661355509065669e-20 3.399830026099863664e-20 6.067755700797460437e-21 7.988262917725085199e-26 6.048192372600482887e-21 1.650677423211890945e-23 7.234441956498974562e-23 1.388191641944564292e-21 1.841849292243282730e-21 0.000000000000000000e+00 1.246490224638687953e-21 1.324841919358758727e-20 2.306716230205177342e-21 3.764310017358447011e-20 3.133000106394295585e+02 4.389490254471512410e-20 3.401605471539766263e-20 6.150346860786617066e-21 7.946463404123173885e-26 6.045027563366860862e-21 1.637664770724558564e-23 7.218949484159127289e-23 1.388147998246311275e-21 1.963109749732392972e-21 0.000000000000000000e+00 1.261542649143892279e-21 2.497848332115254010e-20 2.308128638514966121e-21 4.322141730811262932e-20 3.136500199266692448e+02 4.324418185976389946e-20 3.403382068762319885e-20 5.850839024886344332e-21 7.905593632805085147e-26 6.041844498543239267e-21 1.624740572335373717e-23 7.203456187639788913e-23 1.388122445848693293e-21 2.360102328638557391e-21 0.000000000000000000e+00 1.284288352625148545e-21 3.538094127755597985e-20 2.309541121963050450e-21 4.995331775946871175e-20 3.140500199012889766e+02 4.435604000686368943e-20 3.405413704134376082e-20 5.524441498950613945e-21 7.858886565061610033e-26 6.038184924307356173e-21 1.610082363058315289e-23 7.185750034002021735e-23 1.388115134855263974e-21 2.153434967281337400e-21 0.000000000000000000e+00 1.307816385943796579e-21 2.011104106093162795e-20 2.311155345825051995e-21 4.055537873699880922e-20 3.144000106022051000e+02 4.410228545923996441e-20 3.407192467035816042e-20 5.389790646265405936e-21 7.818076317702672842e-26 6.034982881724506670e-21 1.597357157364519894e-23 7.170257560213486995e-23 1.388108759400035922e-21 2.051957253934033101e-21 0.000000000000000000e+00 1.308799885807972089e-21 1.290893705613242249e-20 2.312567754266914054e-21 3.749948354223745953e-20 3.147500198570288035e+02 4.303333977789846395e-20 3.408972376372406655e-20 6.282690350305905662e-21 7.777360955406853786e-26 6.031815777888569112e-21 1.584727343575999278e-23 7.154764265129054590e-23 1.388067320528376644e-21 2.304217725245884122e-21 0.000000000000000000e+00 1.321850722488034407e-21 9.914699686852075998e-21 2.313980237584181848e-21 3.675063060785640367e-20 3.151000105786521317e+02 4.160295792221516819e-20 3.410753241897364674e-20 6.518591787756019115e-21 7.736647749013937416e-26 6.028650968171762861e-21 1.572196574930721805e-23 7.139271790423908147e-23 1.388023778701228832e-21 2.464371112692764191e-21 0.000000000000000000e+00 1.319816567139443619e-21 8.273395159050067116e-21 2.315392646109608954e-21 3.641040434456614322e-20 3.154500198129649675e+02 4.283284268110460756e-20 3.412535250467330486e-20 6.375800775977965141e-21 7.696571495906994572e-26 6.025494559568208371e-21 1.559765896265248703e-23 7.123778496247397015e-23 1.387980602655466186e-21 2.412342102644236283e-21 0.000000000000000000e+00 1.298255065187828625e-21 1.037374764244147056e-20 2.316789641748253305e-21 3.693123240681862518e-20 3.158000105552035848e+02 4.207334675650160852e-20 3.414318212037246357e-20 5.969242474994433767e-21 7.656976583653738504e-26 6.022363063453442116e-21 1.547439049672669078e-23 7.108286020629706079e-23 1.387938138931539600e-21 2.525213087331433811e-21 0.000000000000000000e+00 1.259282114586509465e-21 1.056368840908853661e-20 2.318184769481281485e-21 3.693937260460310130e-20 3.161500197690963319e+02 4.191554236943546880e-20 3.416102313271980606e-20 5.473055176240270292e-21 7.617379581677993204e-26 6.019231402065980208e-21 1.535217218786241816e-23 7.092792727357098381e-23 1.387895688813211569e-21 2.015119661148797571e-21 0.000000000000000000e+00 1.259206880093497077e-21 1.175256215523434670e-20 2.319579970845734303e-21 3.720540256046573633e-20 3.165500197441156729e+02 4.256834342323314035e-20 3.418142510473821376e-20 5.393076937241098588e-21 7.572849812351985613e-26 6.015652454921070108e-21 1.521382431698161523e-23 7.075086573701642365e-23 1.387872442611445405e-21 2.415923731385500661e-21 0.000000000000000000e+00 1.233806395842602251e-21 8.714517768684213334e-21 2.321174444616071176e-21 3.639044158855070516e-20 3.169000105185651250e+02 4.193958924638862327e-20 3.419928752584723314e-20 4.919690470765739372e-21 7.534070834542986686e-26 6.012520958518101226e-21 1.509396300596191312e-23 7.059594096658126151e-23 1.387866844259247853e-21 2.127508521948112289e-21 0.000000000000000000e+00 1.240859879762815546e-21 9.321460564549967701e-21 2.322569572477497569e-21 3.647226889166107973e-20 3.172500197005510358e+02 4.402229010316304521e-20 3.421716129068799441e-20 4.894513967264389656e-21 7.495309856580051130e-26 6.009389297416122321e-21 1.497523397798131576e-23 7.044100804797886671e-23 1.387861261758456205e-21 1.985755391228911090e-21 0.000000000000000000e+00 1.243670173119621996e-21 9.390198722457863952e-21 2.323964773714764156e-21 3.649494599074474775e-20 3.176000104953818663e+02 4.314784174334869176e-20 3.423504450398864956e-20 5.261583440474406079e-21 7.457230858102456345e-26 6.006257800830793453e-21 1.485767700780952830e-23 7.028608326852182070e-23 1.387819929764164054e-21 1.727275815325781109e-21 0.000000000000000000e+00 1.255030565871799960e-21 1.146852614171414573e-20 2.325359901657434700e-21 3.713787614157784236e-20 3.179500196571781885e+02 4.139342598758156527e-20 3.425293902747459698e-20 5.776656613886736211e-21 7.419149861299015349e-26 6.003126139909457749e-21 1.474130764370163921e-23 7.013115035885642733e-23 1.387777561568626241e-21 1.746939519081454076e-21 0.000000000000000000e+00 1.289041766035330460e-21 8.791687844183829924e-21 2.326755102814221489e-21 3.649689260981777748e-20 3.183500196324794160e+02 4.174284366903988614e-20 3.427340205390271720e-20 6.529108566927599994e-21 7.375761887545218042e-26 5.999574828215804683e-21 1.460981589735689858e-23 6.995408882217708845e-23 1.387729314883574381e-21 1.474640843250823005e-21 0.000000000000000000e+00 1.288427736529701301e-21 1.024338935240479577e-20 2.328349576585681947e-21 3.700545897093064149e-20 3.187000104591568856e+02 4.278321423814500390e-20 3.429131780923011357e-20 6.455540246936907157e-21 7.338102874594721693e-26 5.996512408482377193e-21 1.449610729603385978e-23 6.979916402862298521e-23 1.387687366384446642e-21 1.526201890319635241e-21 0.000000000000000000e+00 1.291819057512519300e-21 9.684962284916359570e-21 2.329744704655299110e-21 3.686029964430092652e-20 3.190500195894054514e+02 4.175055612193034935e-20 3.430924482222716439e-20 5.225790194871629474e-21 7.300441892179975097e-26 5.993449828592702109e-21 1.438367809300741608e-23 6.964423113292233542e-23 1.387645431552182344e-21 1.220778396670183853e-21 0.000000000000000000e+00 1.297167376692095239e-21 1.005712660860813851e-20 2.331138900256069746e-21 3.677007164297006182e-20 3.194000104362344814e+02 4.195501553278531601e-20 3.432718120278836484e-20 5.580749240905941300e-21 7.263102897933641075e-26 5.990342011886323137e-21 1.427257041328553574e-23 6.948930633044807559e-23 1.387627458177973962e-21 1.321565883148992217e-21 0.000000000000000000e+00 1.313386046578422534e-21 1.099922760986702184e-20 2.332532679596345002e-21 3.711078155040837709e-20 3.197500195465201500e+02 4.308366839665817963e-20 3.434512880772741417e-20 5.784874741402491295e-21 7.226141935887475659e-26 5.987210351425872249e-21 1.416280362132028727e-23 6.933437344358407528e-23 1.387621990223955315e-21 1.391356341633492735e-21 0.000000000000000000e+00 1.322350733448006164e-21 1.006863180861031826e-20 2.333926531667746750e-21 3.689632613828757644e-20 3.201500195220984324e+02 4.164540075424634125e-20 3.436565239828741792e-20 6.233831397786949850e-21 7.183901938466407556e-26 5.983637329181639063e-21 1.403904861347486970e-23 6.915731190678209706e-23 1.387612636101753986e-21 1.299202931071471300e-21 0.000000000000000000e+00 1.316294834041094877e-21 8.902721437112689334e-21 2.335519463903325856e-21 3.668414839551491514e-20 3.205000104004158743e+02 4.169844615313890055e-20 3.438362105953205873e-20 5.942621664373857796e-21 7.147523677422360984e-26 5.980574908996361324e-21 1.393228012791533648e-23 6.900238709036936595e-23 1.387570769560412530e-21 1.352007111436514251e-21 0.000000000000000000e+00 1.312116975356583059e-21 2.035350759000008936e-20 2.336913243368998335e-21 4.096976620200093529e-20 3.208500194795070115e+02 4.064379097511795283e-20 3.440160089303849894e-20 6.088173572560596669e-21 7.111344521128187316e-26 5.977512329554313737e-21 1.382695387577567667e-23 6.884745421731374496e-23 1.387528916708799290e-21 1.222744061960962557e-21 0.000000000000000000e+00 1.300634397689128129e-21 9.980356199146404528e-21 2.338307095316173088e-21 3.696564304284766138e-20 3.212000103777500044e+02 4.159027983451839442e-20 3.441959001385505837e-20 5.850077120396712387e-21 7.075167244121682993e-26 5.974448362669200816e-21 1.372311413814484395e-23 6.869252939208089182e-23 1.387487210692302463e-21 1.234049643202152161e-21 0.000000000000000000e+00 1.285661951000469470e-21 8.111677296610705024e-21 2.339700874861195762e-21 3.648294058802374896e-20 3.215500194371009570e+02 4.196917458850047820e-20 3.443759027389552743e-20 6.050842300929394610e-21 7.039463368184181781e-26 5.971381272973857322e-21 1.362078400823221649e-23 6.853759652776334335e-23 1.387445765208310103e-21 1.322305743153952105e-21 0.000000000000000000e+00 1.269788257465480210e-21 7.400982560653796126e-21 2.341094726729758719e-21 3.638356389215721505e-20 3.219500194129517467e+02 4.321657954488897801e-20 3.445817394211704089e-20 6.399308381099604569e-21 6.998750499355010703e-26 5.967876118546298979e-21 1.350573754380577223e-23 6.836053499084073591e-23 1.387398419607255344e-21 1.366107408145807305e-21 0.000000000000000000e+00 1.249036043518144179e-21 8.736396680926707064e-21 2.342687658966423041e-21 3.675733025422028374e-20 3.223000103423310065e+02 4.124608258671229617e-20 3.447619508430695611e-20 6.407455069408161097e-21 6.963191042926835135e-26 5.964812409504603506e-21 1.340677544009049774e-23 6.820561015182529378e-23 1.387356741974978620e-21 1.404964048789719041e-21 0.000000000000000000e+00 1.262998323910460010e-21 8.730880065723510173e-21 2.344081438635440620e-21 3.677586380735450035e-20 3.226500193708347410e+02 4.092161011390989450e-20 3.449422731400304389e-20 6.952612800629569839e-21 6.928120831357944811e-26 5.961749830505196310e-21 1.330943299684829165e-23 6.805067730116238174e-23 1.387314970757435942e-21 1.058607867759114291e-21 0.000000000000000000e+00 1.272681095440170260e-21 8.926842717340744434e-21 2.345469204842735043e-21 3.692685430868805462e-20 3.230500193468497514e+02 4.005936886702774983e-20 3.451484745849597035e-20 6.525990570188918881e-21 6.888041625840401682e-26 5.958253440707693114e-21 1.320022294413625437e-23 6.787361576416708172e-23 1.387271418960261323e-21 1.152870473416467892e-21 0.000000000000000000e+00 1.278259129235690014e-21 1.281485258104621457e-20 2.347047452745579738e-21 3.799980881908082510e-20 3.234000103071530248e+02 3.991640315124641772e-20 3.453290046458996095e-20 6.585950217563750706e-21 6.853127692361084904e-26 5.955222591154550775e-21 1.310648846348897684e-23 6.771869091146301964e-23 1.387266118563735226e-21 1.237968325923415426e-21 0.000000000000000000e+00 1.294790360621878863e-21 1.257651115967042867e-20 2.348428384076166922e-21 3.794973902734578462e-20 3.237500193050187818e+02 3.899745533156428466e-20 3.455096450671515050e-20 5.996487054120528909e-21 6.818473336136752727e-26 5.952191585399837555e-21 1.301448817472983233e-23 6.756375807436211506e-23 1.387260834049209670e-21 1.109805373547168367e-21 0.000000000000000000e+00 1.306065040920650387e-21 1.085607422026093201e-20 2.349809386576121438e-21 3.732824992356054623e-20 3.241500192811964212e+02 4.097510502052355411e-20 3.457162094808493555e-20 6.135909929391751113e-21 6.778869378099362177e-26 5.948742691875459211e-21 1.291152473574808972e-23 6.738669653729482777e-23 1.387237476325597202e-21 1.107201014285770704e-21 0.000000000000000000e+00 1.303841236353145773e-21 1.040318531365325835e-20 2.351387634479607859e-21 3.724035748058708943e-20 3.245000102722135011e+02 4.216836826041578098e-20 3.458970566136882408e-20 5.820477339241671590e-21 6.744775479621755250e-26 5.945742769095312444e-21 1.282338091443293680e-23 6.723177167099517435e-23 1.387196535140276609e-21 1.032395407620945011e-21 0.000000000000000000e+00 1.300692670494443790e-21 1.155555769113379481e-20 2.352768565931380047e-21 3.754238438396782231e-20 3.248500192396485318e+02 3.937832494405536479e-20 3.460780135945120791e-20 5.470089726913943569e-21 6.711009908645672103e-26 5.942742692231583591e-21 1.273708931653816447e-23 6.707683884736456516e-23 1.387156024964112886e-21 1.047449572407963357e-21 0.000000000000000000e+00 1.288327739570268461e-21 1.127122187804739325e-20 2.354149568311265997e-21 3.741932993019896634e-20 3.252500192159871517e+02 3.933137157072855523e-20 3.462849411085638271e-20 5.479501631060666304e-21 6.672421675634182180e-26 5.939288493387327573e-21 1.268542704898122110e-23 6.692171923744932088e-23 1.387109514874413794e-21 1.087665677811925858e-21 0.000000000000000000e+00 1.268781867176223010e-21 1.511262880383165701e-20 2.355727816215387748e-21 3.876977211082140538e-20 3.256000102375101051e+02 3.996245186779516573e-20 3.464661054940600874e-20 5.387341428039794031e-21 6.639404863115558123e-26 5.936257643304036152e-21 1.264205766176607677e-23 6.678684764075553405e-23 1.387068732416579885e-21 9.904177324208796859e-22 0.000000000000000000e+00 1.268440895966945352e-21 1.438409934729620565e-20 2.357108747787524540e-21 3.849190759474913011e-20 3.259500191747195004e+02 3.993118309159628297e-20 3.466473792067049037e-20 6.277026260012352850e-21 6.606510819307916783e-26 5.933230449846763303e-21 1.259873347139455430e-23 6.665196914012112503e-23 1.387030023536284209e-21 6.797542471902915359e-22 0.000000000000000000e+00 1.269117305565031703e-21 1.706029159223555349e-20 2.358489750048151791e-21 3.970976628661164342e-20 3.263500191512175093e+02 3.984343546132167573e-20 3.468546661735366377e-20 6.362710395624737512e-21 6.568923695238831555e-26 5.929842694943770233e-21 1.254928006878354900e-23 6.649782622733150413e-23 1.387024657357448735e-21 6.456818188114700304e-22 0.000000000000000000e+00 1.275147406345718787e-21 1.522865553128215792e-20 2.360062096330170054e-21 3.898950984029831455e-20 3.267000102030403923e+02 3.742849931673904655e-20 3.470361444846702478e-20 6.484202703996889845e-21 6.536120612342490455e-26 5.926878485015066208e-21 1.250606135543151705e-23 6.636295461896142612e-23 1.387019976333176202e-21 7.846083722804812613e-22 0.000000000000000000e+00 1.275276016188209580e-21 1.608469297719491469e-20 2.361426868230296014e-21 3.936975537354507049e-20 3.270500191102272538e+02 3.833467655876802376e-20 3.472177316155018320e-20 5.944078855913802926e-21 6.503315855943410439e-26 5.923899836198051929e-21 1.246288941786473963e-23 6.622807612989642058e-23 1.387001029116964713e-21 7.695554648779567162e-22 0.000000000000000000e+00 1.283770179830292514e-21 1.519661932996779253e-20 2.362791709756484840e-21 3.894502295222390446e-20 3.274500190868829463e+02 3.896125941283436861e-20 3.474253761815058880e-20 5.653348376112056024e-21 6.466072044498066111e-26 5.920471264969575162e-21 1.241361195013680722e-23 6.607393321704603837e-23 1.386954918211880438e-21 6.730055553050921540e-22 0.000000000000000000e+00 1.295568927371295986e-21 1.576549380347958867e-20 2.364351488857543199e-21 3.914405191053720797e-20 3.278500190635955960e+02 3.905811117026379856e-20 3.476331503469045898e-20 5.985062341671628401e-21 6.429567192254385098e-26 5.917042693740609390e-21 1.236439989569812165e-23 6.591979030417370968e-23 1.386908824384342356e-21 6.232417425233540644e-22 0.000000000000000000e+00 1.306770854032311864e-21 1.933828411806789989e-20 2.365911267958823491e-21 4.077880946222378139e-20 3.282000101564085526e+02 4.019721443621665547e-20 3.478150542509518264e-20 5.190013289021397107e-21 6.397626257570483661e-26 5.914100924951322072e-21 1.232139471491599622e-23 6.578491868000780878e-23 1.386868826666926613e-21 5.500501576670602701e-22 0.000000000000000000e+00 1.323203109179448840e-21 2.264209919438297788e-20 2.367276040018788470e-21 4.235464443679628587e-20 3.285500190229792565e+02 3.874077569317112542e-20 3.479970662865962125e-20 5.263497945859914661e-21 6.365881781230607387e-26 5.911166507181083394e-21 1.227843856630512159e-23 6.565004020659453404e-23 1.386828881185586787e-21 6.472032384646326458e-22 0.000000000000000000e+00 1.318332201583128430e-21 1.947566515456476019e-20 2.368640881386596643e-21 4.077575874515833661e-20 3.289500189998474866e+02 3.560311469063773228e-20 3.482051956540828460e-20 5.512776203874883371e-21 6.329842948363258675e-26 5.907806981940067043e-21 1.222941047654579905e-23 6.549589729366224338e-23 1.386783174255249660e-21 6.881413606551601580e-22 0.000000000000000000e+00 1.328422089059448877e-21 1.388797033276963418e-20 2.370200660488483678e-21 3.847623798367132501e-20 3.293000101224819218e+02 3.658595101933081564e-20 3.483874098453427714e-20 6.109872286526378239e-21 6.298309767605516690e-26 5.904842771411632947e-21 1.218656807408573362e-23 6.536102565800441584e-23 1.386742898293216611e-21 4.058314423513358287e-22 0.000000000000000000e+00 1.322956658241428567e-21 1.165245006518354512e-20 2.371565432664735705e-21 3.783096464469900618e-20 3.296500189595019492e+02 3.453140315546946147e-20 3.485697316664282299e-20 5.564299033814203083e-21 6.267259868566946660e-26 5.901878410853197502e-21 1.214377643810556344e-23 6.522614719597870735e-23 1.386702633374013344e-21 5.907081747265214478e-22 0.000000000000000000e+00 1.306664054296850815e-21 1.398224806455686449e-20 2.372930273917312705e-21 3.854763135518620211e-20 3.300500189365242250e+02 3.401482151322676790e-20 3.487782144882245602e-20 5.025122129977145777e-21 6.232029101359984156e-26 5.898487718114340019e-21 1.209493848687090777e-23 6.507200428298706599e-23 1.386676012343583869e-21 6.052796531475003976e-22 0.000000000000000000e+00 1.301409884070643558e-21 1.152261856130387759e-20 2.374489637527485188e-21 3.766832436558790827e-20 3.304500189136020936e+02 3.140432122066823141e-20 3.489868254071902400e-20 4.832181729054518491e-21 6.196798363245974189e-26 5.895093778914891362e-21 1.204617125684432044e-23 6.491786136997399536e-23 1.386670823271777059e-21 5.762480490704072250e-22 0.000000000000000000e+00 1.273122708566981414e-21 1.305539736258837024e-20 2.376045845561320653e-21 3.815742741351979241e-20 3.308000100765818843e+02 3.197092353679300491e-20 3.491694602583206565e-20 4.901954578101768044e-21 6.166510666449646000e-26 5.892124156925972075e-21 1.200355969448993774e-23 6.478298971876879741e-23 1.386666297215516713e-21 4.762585971179931532e-22 0.000000000000000000e+00 1.247889727118835844e-21 1.229277699546985859e-20 2.377407493288351651e-21 3.792644293305115120e-20 3.311500188736217183e+02 3.163797810142602722e-20 3.493522020588982189e-20 6.397209322224174838e-21 6.136221443628892230e-26 5.889209843348940085e-21 1.196100137834777418e-23 6.464811127214974090e-23 1.386631798843221355e-21 5.043452796258972559e-22 0.000000000000000000e+00 1.241194460293635530e-21 1.178250839613710072e-20 2.378769209621051721e-21 3.800374633671742391e-20 3.315500188508515294e+02 3.654071415943572679e-20 3.495611640625482115e-20 6.812284518006780132e-21 6.101675313504218204e-26 5.885889843537932434e-21 1.191243311696172980e-23 6.449396835907811890e-23 1.386586679321799385e-21 6.594703818562019750e-22 0.000000000000000000e+00 1.245007630058637908e-21 1.737409535691864869e-20 2.380325417655478131e-21 4.017982082540783447e-20 3.319500188281362512e+02 2.102421083716564558e-18 3.497702533045551875e-20 6.078343933004431167e-21 6.067521469289905542e-26 5.882561458309564973e-21 1.186393887732382189e-23 6.433982544598534975e-23 1.386541475925740894e-21 1.680510323761777807e-21 0.000000000000000000e+00 1.245012577273166833e-21 3.074517254377830799e-20 2.381881625690118575e-21 4.745717057486332699e-20 3.323000100310962921e+02 3.349313894077844156e-20 3.499533059953578960e-20 6.033555483300385598e-21 6.037637605037163197e-26 5.879627188628182852e-21 1.182156891661479892e-23 6.420495377937346456e-23 1.386501672988054678e-21 5.008061895104958255e-22 0.000000000000000000e+00 1.253070324661849085e-21 1.979391638559445841e-20 2.383243273572693619e-21 4.119312547981138026e-20 3.326500187885159789e+02 3.797787692841476272e-20 3.501364649596641778e-20 7.045897398897813082e-21 6.007890725121154337e-26 5.876692771773047530e-21 1.177925482181903062e-23 6.407007534802231643e-23 1.386461881146428203e-21 6.184696274632937388e-22 0.000000000000000000e+00 1.276672728030490406e-21 1.810174829485893459e-20 2.384604989751250456e-21 4.058859666868457598e-20 3.330500187659505400e+02 4.343115228315598574e-20 3.503459029324974304e-20 7.021222671104501435e-21 5.974198419329551593e-26 5.873377846119205081e-21 1.173096888246609007e-23 6.391593243487179524e-23 1.386416633956511221e-21 7.768257780484662011e-22 0.000000000000000000e+00 1.285986004627255404e-21 1.962097459246425938e-20 2.386161197786473569e-21 4.130468077105066121e-20 3.334500187434393297e+02 4.529102277348025711e-20 3.505554672905986827e-20 7.221640296952114601e-21 5.940506113533380033e-26 5.870097846303797585e-21 1.168276045337660265e-23 6.376178952170038553e-23 1.386371595669999358e-21 7.659964056033560764e-22 0.000000000000000000e+00 1.295029435832030900e-21 1.820124672936063503e-20 2.387717405821907707e-21 4.070231136779264549e-20 3.338500187209820069e+02 4.609276619856707741e-20 3.507651578074419806e-20 6.396823926122340934e-21 5.907465133329093943e-26 5.866816844615848867e-21 1.163463049804884032e-23 6.360764660850819307e-23 1.386327575837434857e-21 6.879034022726651951e-22 0.000000000000000000e+00 1.303957618918695522e-21 2.171035189716172671e-20 2.389272544231016256e-21 4.227113034148994946e-20 3.342000099740673136e+02 4.409654920767369979e-20 3.509487357426397619e-20 7.000747214769042228e-21 5.878799183076392993e-26 5.863911917215240760e-21 1.159258297628984820e-23 6.347277492258017329e-23 1.386323376584753639e-21 5.977145116955619734e-22 0.000000000000000000e+00 1.301039365522784186e-21 2.255989176927949585e-20 2.390616725175209304e-21 4.282155838426491094e-20 3.345500186818109114e+02 4.340807298986265069e-20 3.511324191014884175e-20 6.642694546253773877e-21 5.850131803204061840e-26 5.861006844940969436e-21 1.155059485339450979e-23 6.333789651037207996e-23 1.386319448460666343e-21 7.636413096006266328e-22 0.000000000000000000e+00 1.315785373800203798e-21 2.203801477716188215e-20 2.391960973155988838e-21 4.250944116368772754e-20 3.349500186595009268e+02 4.202269867948545937e-20 3.513424553901517624e-20 5.753282366057327396e-21 5.817621343057642243e-26 5.857695886263507052e-21 1.150268578757607946e-23 6.318375359712312288e-23 1.386304085053827744e-21 7.262905955729093963e-22 0.000000000000000000e+00 1.323247943072498775e-21 1.812357415810484414e-20 2.393497218256255235e-21 4.049969486971046427e-20 3.353500186372442045e+02 4.158116225339772635e-20 3.515526169916881797e-20 5.750567242389608634e-21 5.785164202006474474e-26 5.854408757733537383e-21 1.145485893905780680e-23 6.302961068385362991e-23 1.386260039227915329e-21 8.093690116835942360e-22 0.000000000000000000e+00 1.322501952645811696e-21 1.828415957618267657e-20 2.395033463356726638e-21 4.059078882953591536e-20 3.357000099295004247e+02 4.106999697064289071e-20 3.517366064435600414e-20 6.182554590545264409e-21 5.756833179145065442e-26 5.851532591668461804e-21 1.141307973942104858e-23 6.289473898283080505e-23 1.386221511328213474e-21 8.065926335386017724e-22 0.000000000000000000e+00 1.327584662461505504e-21 1.928141286532983455e-20 2.396377644451359640e-21 4.112791138338692719e-20 3.360500185984223549e+02 4.061105363920894202e-20 3.519207006531346611e-20 5.639170760667023387e-21 5.729228721860278754e-26 5.848659847492936718e-21 1.137136290881094178e-23 6.275986058558292270e-23 1.386182794071242738e-21 4.744167484309752585e-22 0.000000000000000000e+00 1.330714369676131196e-21 1.964459357034304615e-20 2.397721892283040223e-21 4.123189825866592028e-20 3.364500185763109812e+02 4.098900803939902347e-20 3.521312057081633067e-20 6.352182129678633062e-21 5.697681553792834502e-26 5.845379847674249875e-21 1.132376753714125734e-23 6.260571767225742918e-23 1.386138390094318413e-21 8.242938929297545110e-22 0.000000000000000000e+00 1.324281936529908165e-21 2.189773640538809982e-20 2.399258137384069469e-21 4.247479786190151146e-20 3.368500185542521308e+02 3.972815928894743537e-20 3.523418352358727901e-20 6.175711084740267108e-21 5.666270255782666347e-26 5.842099850838365089e-21 1.127625834184929074e-23 6.245157475891169365e-23 1.386094001677173386e-21 7.520311240248394775e-22 0.000000000000000000e+00 1.324034183017982219e-21 1.895960651032197972e-20 2.400794382485300711e-21 4.102671837478090847e-20 3.372500185322456332e+02 3.969449160558115049e-20 3.525525890131676597e-20 5.901356370559527459e-21 5.635175917870719347e-26 5.838884164740770555e-21 1.122883641677171318e-23 6.229743184554577488e-23 1.386089605208625077e-21 7.093260181857676713e-22 0.000000000000000000e+00 1.329776017169803286e-21 1.643094569463256145e-20 2.402330627586732823e-21 3.989731474014541529e-20 3.376500185102912610e+02 4.030616975510144562e-20 3.527634668173542008e-20 6.835506782828095813e-21 5.604081579954720104e-26 5.835668478642756980e-21 1.118150287227509587e-23 6.214328893215977867e-23 1.386085222699681748e-21 7.214954107674029427e-22 0.000000000000000000e+00 1.333738367035915524e-21 2.158321706585711681e-20 2.403866872688365050e-21 4.243864138206793392e-20 3.380000098619328242e+02 4.059700304182755037e-20 3.529480819091320509e-20 6.982942042672841803e-21 5.577112452085902994e-26 5.832844474388268348e-21 1.114016042468152692e-23 6.200841720825238277e-23 1.386068533614352636e-21 7.881209111079056359e-22 0.000000000000000000e+00 1.349096155125975032e-21 1.888902202816704804e-20 2.405197951675772861e-21 4.117588517531439002e-20 3.383500184719959520e+02 4.113421680851661291e-20 3.531328007460006434e-20 6.547103989388634684e-21 5.550300471767861025e-26 5.830002820326369403e-21 1.109888523508235565e-23 6.187353883368616938e-23 1.386030083552607720e-21 6.527410380232765850e-22 0.000000000000000000e+00 1.336665038755787448e-21 2.002934307401119000e-20 2.406527013015079666e-21 4.165315095650082562e-20 3.387500184501840295e+02 4.144230119484783194e-20 3.533440184791493135e-20 6.611173735288181165e-21 5.519658964004775013e-26 5.826755295750980840e-21 1.105180060057997021e-23 6.171939592024527758e-23 1.385986154564420280e-21 6.764356292496868174e-22 0.000000000000000000e+00 1.327902446657265364e-21 2.308860230294397732e-20 2.408045902812211345e-21 4.323432282199408068e-20 3.391500184284234933e+02 4.090726828717309690e-20 3.535553594076586285e-20 6.519238374140693840e-21 5.489243885240335087e-26 5.823502791219690813e-21 1.100480866230878511e-23 6.156525300678457870e-23 1.385942501266950620e-21 7.039672713277522903e-22 0.000000000000000000e+00 1.332761200706377937e-21 1.972651043788890471e-20 2.409564792609538627e-21 4.153992491912033012e-20 3.395500184067142868e+02 4.067932780272527281e-20 3.537668233107373315e-20 6.560499937593112057e-21 5.458904264245447314e-26 5.820247889435559960e-21 1.095791061282541199e-23 6.141111009330410801e-23 1.385898987797380942e-21 7.067669661432462832e-22 0.000000000000000000e+00 1.304890712211472846e-21 1.975141430282150309e-20 2.411083682407060759e-21 4.157503645082547481e-20 3.399500183850561257e+02 4.048121926773991579e-20 3.539784099679930736e-20 6.414023430152658048e-21 5.428652851642598745e-26 5.817002795177495621e-21 1.091110766278653498e-23 6.125696717980395954e-23 1.385855488047115296e-21 7.442482438759057584e-22 0.000000000000000000e+00 1.285232518522708812e-21 1.969235657866290782e-20 2.412602572204776613e-21 4.154183576936784702e-20 3.403000097952785836e+02 4.142136838893521384e-20 3.541636445458321646e-20 6.848241494333553026e-21 5.402877783300982910e-26 5.814223451625729357e-21 1.087207029592022640e-23 6.112558870251713914e-23 1.385817437952437118e-21 5.414717738814715793e-22 0.000000000000000000e+00 1.268752692543561628e-21 2.015759079979382997e-20 2.413931568232423359e-21 4.184501498564146592e-20 3.406500183472767844e+02 3.876479879413809526e-20 3.543489829258153856e-20 6.909377055704707963e-21 5.377101452555694347e-26 5.811443971948096370e-21 1.084040177495954359e-23 6.100816883591816431e-23 1.385779396500110769e-21 7.467613140236163483e-22 0.000000000000000000e+00 1.256576540753338465e-21 1.914278555902317703e-20 2.415260629351244287e-21 4.139426256525840495e-20 3.410500183257582307e+02 4.004363863026153646e-20 3.545609075289762580e-20 5.470322829000990745e-21 5.347695860365290454e-26 5.808254754636061249e-21 1.080421896488833685e-23 6.087397798873815355e-23 1.385748675412337835e-21 8.325737760466278231e-22 0.000000000000000000e+00 1.258810915818780270e-21 1.877732814717149640e-20 2.416779519149490148e-21 4.102956748489617029e-20 3.414500183042900403e+02 4.045708606160335871e-20 3.547729540528292869e-20 6.278058389432782989e-21 5.318536983425587660e-26 5.805039068534138639e-21 1.076804573872109936e-23 6.073978714154126270e-23 1.385744424606561913e-21 1.015523810002364374e-21 0.000000000000000000e+00 1.284495176556801941e-21 1.594227869210007453e-20 2.418298408947927472e-21 3.995448299560813576e-20 3.418500182828721563e+02 4.090160741032472094e-20 3.549851222788906600e-20 6.498640113558149385e-21 5.289378106482218333e-26 5.801823382431812035e-21 1.073188219336933082e-23 6.060559629432747999e-23 1.385740187764776035e-21 9.528835296473242294e-22 0.000000000000000000e+00 1.337896260110236385e-21 1.516840378352805841e-20 2.419815487893567058e-21 3.970637034685918999e-20 3.422500182615042945e+02 3.913201762269795275e-20 3.551974119890731261e-20 6.110629913791445979e-21 5.260650560019512020e-26 5.798631893452101711e-21 1.069572842702911704e-23 6.047140544709692298e-23 1.385705879840535152e-21 7.125539894622330674e-22 0.000000000000000000e+00 1.303909313608355715e-21 1.611800186468428127e-20 2.421331330291080053e-21 4.002999673746101937e-20 3.426500182401863412e+02 4.006195919909536687e-20 3.554098229656856336e-20 5.974744864415363836e-21 5.232354265231264445e-26 5.795447427602399635e-21 1.065958453920197879e-23 6.033721459984962693e-23 1.385662853592489776e-21 9.213076483609034679e-22 0.000000000000000000e+00 1.314099889440340999e-21 1.416966149528342109e-20 2.422847172688782256e-21 3.928861396198918853e-20 3.430000097181728620e+02 3.879720548662755601e-20 3.555957773566808078e-20 5.135614841562985132e-21 5.207595608825551196e-26 5.792664001245436513e-21 1.062796758812522586e-23 6.021980046119117878e-23 1.385625217803078074e-21 7.281589900340485424e-22 0.000000000000000000e+00 1.330441212527614816e-21 1.572508512489349360e-20 2.424173502562384897e-21 3.977174839112112094e-20 3.433500182029994221e+02 3.984618477869817141e-20 3.557818333187454059e-20 4.915318004184792902e-21 5.182998725790042459e-26 5.789911507335635491e-21 1.059635680970903130e-23 6.010238061712675979e-23 1.385587590698484767e-21 7.369279805478044840e-22 0.000000000000000000e+00 1.317916409266922257e-21 1.217529348264282448e-20 2.425499896885213910e-21 3.849434920534750119e-20 3.437500181818177225e+02 3.930235795593877437e-20 3.559945766588026504e-20 6.390736400735327245e-21 5.154998727272760259e-26 5.786765876434249048e-21 1.056024061175707600e-23 5.996818976983374877e-23 1.385544602212722580e-21 9.686948161728891835e-22 0.000000000000000000e+00 1.308370271297564084e-21 1.488917109325205965e-20 2.427015739283432578e-21 3.967116109169923100e-20 3.441500181606852493e+02 4.055795802012716936e-20 3.562074404524714859e-20 6.279302846540691106e-21 5.126998728752033079e-26 5.783605680662505230e-21 1.052413467744400273e-23 5.983399892252422204e-23 1.385501940938615489e-21 8.910709578264470433e-22 0.000000000000000000e+00 1.289474177075500882e-21 1.419060199192590377e-20 2.428531581681837444e-21 3.941279174814301903e-20 3.445500181396019457e+02 3.873622699129254540e-20 3.564204244839374989e-20 6.617852352036079141e-21 5.099376528160756182e-26 5.780421214810935905e-21 1.048803911277012037e-23 5.969980807519820314e-23 1.385459366708062526e-21 7.613576508461318706e-22 0.000000000000000000e+00 1.273028949831365740e-21 1.150069283381758119e-20 2.430047424080428885e-21 3.859869084714208331e-20 3.449500181185674705e+02 3.766041343725147747e-20 3.566335285377802494e-20 7.007868521106890141e-21 5.071820974054243190e-26 5.777236748958976879e-21 1.045195402516938982e-23 5.956561722785579784e-23 1.385416803740324744e-21 5.227423830482641965e-22 0.000000000000000000e+00 1.262593037361811985e-21 1.224019281807123117e-20 2.431563266479205395e-21 3.890869671916498746e-20 3.453500180975817102e+02 3.961712594537342783e-20 3.568467523989724275e-20 6.162070869301027447e-21 5.044309877794434896e-26 5.774083352824842758e-21 1.041587952353313370e-23 5.943142638049705317e-23 1.385405308179435864e-21 7.170968088624291706e-22 0.000000000000000000e+00 1.262054424540060714e-21 1.382287213688251597e-20 2.433079108878166223e-21 3.931575852838783844e-20 3.457500180766444942e+02 3.882790305684207515e-20 3.570600958528797937e-20 6.083084286470813901e-21 5.017050619962007964e-26 5.770937721921533394e-21 1.037981571823430445e-23 5.929723553312201614e-23 1.385401585908696427e-21 4.464258979895975081e-22 0.000000000000000000e+00 1.275214127934879742e-21 1.071917876268721563e-20 2.434586479403572845e-21 3.833801234306981443e-20 3.461500180557557087e+02 3.889225913423959783e-20 3.572735586852603363e-20 6.378980570870177841e-21 4.989791362126280119e-26 5.767798897834979088e-21 1.034376272115215795e-23 5.916304468573074555e-23 1.385389223263755823e-21 3.851102831174591974e-22 0.000000000000000000e+00 1.292997225369807197e-21 9.329682303749922353e-21 2.436083286494762744e-21 3.804107504514083333e-20 3.465500180349151265e+02 3.808090735115812496e-20 3.574871406822642108e-20 6.559986580288331504e-21 4.962842838781786432e-26 5.764683513381911136e-21 1.030772064569746934e-23 5.902885383832330014e-23 1.385347078875219475e-21 5.006294595094090618e-22 0.000000000000000000e+00 1.324139889298285380e-21 8.430156083782838684e-21 2.437580093586132824e-21 3.788365926455202783e-20 3.469500180141226338e+02 3.855882129323871269e-20 3.577008416304330181e-20 6.263935558979201723e-21 4.936274032823415660e-26 5.761568128928467778e-21 1.027168960683817350e-23 5.889466299089971521e-23 1.385304945755859332e-21 5.966732077703627723e-22 0.000000000000000000e+00 1.334325009938018662e-21 8.613465310365152486e-21 2.439076900677683083e-21 3.789632493838866299e-20 3.473000095978499644e+02 3.710243605737713116e-20 3.578879228795574747e-20 5.705334471404132903e-21 4.913026885427213939e-26 5.758823001247721552e-21 1.024017234903872277e-23 5.877724881676765698e-23 1.385268089405745881e-21 6.263004247158329715e-22 0.000000000000000000e+00 1.331756156958277277e-21 9.759092753116520987e-21 2.440386575457026348e-21 3.810296929655192719e-20 3.476500179778508368e+02 3.725798048507367145e-20 3.580751038753224328e-20 6.313679285897437717e-21 4.889987816492680062e-26 5.756063319790021828e-21 1.020866219711381201e-23 5.865982900786984421e-23 1.385231239916527459e-21 6.016527385622416044e-22 0.000000000000000000e+00 1.342965477944342859e-21 9.450144327750069480e-21 2.441696313088326361e-21 3.813827045103136739e-20 3.480500179571895956e+02 3.906631655448976610e-20 3.582891308417405805e-20 5.927371964846144893e-21 4.863859377475323220e-26 5.752909473799082180e-21 1.017266211471762890e-23 5.852563816040223700e-23 1.385189137792703733e-21 5.717011602232090626e-22 0.000000000000000000e+00 1.344615102613218181e-21 8.853770114555004766e-21 2.443193120180367883e-21 3.795202585046721688e-20 3.484500179365758186e+02 3.968338997598268107e-20 3.585032759623337667e-20 5.681996701254117507e-21 4.837730938454866355e-26 5.749837958578470144e-21 1.013667351436829662e-23 5.839144731291870185e-23 1.385147330722888795e-21 9.852081534704843711e-22 0.000000000000000000e+00 1.362527732288589894e-21 9.576220785015941756e-21 2.444689927272586951e-21 3.811851895803984584e-20 3.488500179160093353e+02 3.959671468904942987e-20 3.587175390254968785e-20 6.933381664341510260e-21 4.811998853375404072e-26 5.746790339687547766e-21 1.010069651879686903e-23 5.825725646541929753e-23 1.385105617295644691e-21 8.578614645996907548e-22 0.000000000000000000e+00 1.380740834733793056e-21 9.918137868973298412e-21 2.446186734364982814e-21 3.842912673916380496e-20 3.492500178954899184e+02 3.847941285977904345e-20 3.589319198200138411e-20 6.710926090359362007e-21 4.786398854688646069e-26 5.743737004806221114e-21 1.006473125244937425e-23 5.812306561790410632e-23 1.385063915145383767e-21 7.111486541721318910e-22 0.000000000000000000e+00 1.347834590766910334e-21 9.020733837885986463e-21 2.447683541457554719e-21 3.818320756895440673e-20 3.496500178750174541e+02 3.987506258574726335e-20 3.591464181350568950e-20 6.426614736263105927e-21 4.760798875498901969e-26 5.740651290678436758e-21 1.002877784151611825e-23 5.798887477037316348e-23 1.385022224273125034e-21 1.346101778944724488e-21 0.000000000000000000e+00 1.339692709820234547e-21 8.739015166456606477e-21 2.449177391476981562e-21 3.810531883060968063e-20 3.500500178545917720e+02 3.745611025587792599e-20 3.593610337601862354e-20 5.640078838986934363e-21 4.735635240420227645e-26 5.737565576550292042e-21 9.992836413961614418e-24 5.785468392282651604e-23 1.384980544679886566e-21 1.377062033389442646e-21 0.000000000000000000e+00 1.326178178762030924e-21 9.159626564989671105e-21 2.450657874775991108e-21 3.810006329751447009e-20 3.504500178342127015e+02 3.963186634405356098e-20 3.595757664853494704e-20 6.478180149823060695e-21 4.710471605338620324e-26 5.734479862421787718e-21 9.956907099555061207e-24 5.772049307526424627e-23 1.384958869993816824e-21 1.265028422314576185e-21 0.000000000000000000e+00 1.310275234757341362e-21 8.206018612651389228e-21 2.452138358075173312e-21 3.803141832418123882e-20 3.508500178138801289e+02 3.907410193659271310e-20 3.597906161008813800e-20 6.367931309477739850e-21 4.685417080596503413e-26 5.731394148292924540e-21 9.920990029901461852e-24 5.758630222768636595e-23 1.384955292974459854e-21 1.778897242963388924e-21 0.000000000000000000e+00 1.285810859087844555e-21 8.036356224459788359e-21 2.453618841374527795e-21 3.801624481604337412e-20 3.512500177935938837e+02 3.830117826381126530e-20 3.600055823975031342e-20 6.548128178639699997e-21 4.660689809123289716e-26 5.728308434163704764e-21 9.885085338473368606e-24 5.745211138009295734e-23 1.384951727432265603e-21 1.634114339529512743e-21 0.000000000000000000e+00 1.295650004260714691e-21 8.124159004879233410e-21 2.455099324674053807e-21 3.807928169389144965e-20 3.516500177733537384e+02 3.954051871257609741e-20 3.602206651663216905e-20 6.573644426863943794e-21 4.635962537647226249e-26 5.725222720034128390e-21 9.849193160643269079e-24 5.731792053248407922e-23 1.384913899531898098e-21 1.957643549198113304e-21 0.000000000000000000e+00 1.318937845219969769e-21 8.999116124435374168e-21 2.456579807973750219e-21 3.831569472050168416e-20 3.520500177531596364e+02 5.343975700211993089e-20 3.604358641988300954e-20 5.950739789919000979e-21 4.611490817106014138e-26 5.722137005904196922e-21 9.813313633716614691e-24 5.718372968485974336e-23 1.384872276602592935e-21 2.184115642298941698e-21 0.000000000000000000e+00 1.333751569997723921e-21 1.211477061493243847e-20 2.458060291273617030e-21 3.909698834068048444e-20 3.524500177330113502e+02 4.100348718720732636e-20 3.606511792869059192e-20 6.083001614936750168e-21 4.587274602109584605e-26 5.719069677486706434e-21 9.777446896965545603e-24 5.704953883722004379e-23 1.384830763766908251e-21 1.861243578291640158e-21 0.000000000000000000e+00 1.330273482645758396e-21 1.186582941942791548e-20 2.459540774573653488e-21 3.904363723012334344e-20 3.528500177129087660e+02 4.145688739803089615e-20 3.608666102228118583e-20 6.692802401240841426e-21 4.563058387110389100e-26 5.716050809713895613e-21 9.741593091663278333e-24 5.691534798956501576e-23 1.384789522657016393e-21 1.850236291861167253e-21 0.000000000000000000e+00 1.317440692723994945e-21 9.857600300152192518e-21 2.461021257873859218e-21 3.860081416863849324e-20 3.532500176928516566e+02 4.287068952905155997e-20 3.610821567991942900e-20 6.559813961635525814e-21 4.539051193869054635e-26 5.713031941940741736e-21 9.705752361119222187e-24 5.678115714189472983e-23 1.384748292835292214e-21 1.801046511361877768e-21 0.000000000000000000e+00 1.319934138446880585e-21 1.041015922340062871e-20 2.462501741174233090e-21 3.874035755454839215e-20 3.536500176728399651e+02 4.202066937661212110e-20 3.612978188090836344e-20 7.624938001972431473e-21 4.515123267138223168e-26 5.710013074167245555e-21 9.669924850714773055e-24 5.664696629420920948e-23 1.384707074302744194e-21 2.038719895420487584e-21 0.000000000000000000e+00 1.327479650991712224e-21 1.180613007397258068e-20 2.463982091917695313e-21 3.936242217879420004e-20 3.540500176528734642e+02 4.199145097125188641e-20 3.615135960458931503e-20 6.149744673281628252e-21 4.491195340404687719e-26 5.706994206393407822e-21 9.634110707939909492e-24 5.651277544650852526e-23 1.384666009332325205e-21 2.126297472499281332e-21 0.000000000000000000e+00 1.313153058946595216e-21 1.300165419927369589e-20 2.465459984636624979e-21 3.950439908287562218e-20 3.544500176329520400e+02 4.311129127677211100e-20 3.617294883034189352e-20 6.087923303124533851e-21 4.467678243541917972e-26 5.703975338619230043e-21 9.598310082430467645e-24 5.637858459879272418e-23 1.384625174642935294e-21 2.084380661200558023e-21 0.000000000000000000e+00 1.316150573763945984e-21 1.313556788267794666e-20 2.466937877355721283e-21 3.955637307191122686e-20 3.548500176130755221e+02 4.375687162009892586e-20 3.619454953758393838e-20 7.124651497127757944e-21 4.444182749213944227e-26 5.700919676730272037e-21 9.562523126006241962e-24 5.624439375106185326e-23 1.384621129262343852e-21 1.980960953307100490e-21 0.000000000000000000e+00 1.331686596955353248e-21 1.374580252241933064e-20 2.468415770074983097e-21 3.994952752889909885e-20 3.552500175932437969e+02 4.384039646855656312e-20 3.621616170577143451e-20 6.406952583466490427e-21 4.420773988388483762e-26 5.697863073108231393e-21 9.526749992709849972e-24 5.611020290331595953e-23 1.384618034469523851e-21 1.755950335744554650e-21 0.000000000000000000e+00 1.328388932914933597e-21 1.537183228680896150e-20 2.469893662794410796e-21 4.042631619651261312e-20 3.556500175734566369e+02 4.275736547992516901e-20 3.623778531439850626e-20 4.609745145667262948e-21 4.397773989526245613e-26 5.694827905992847512e-21 9.490990838846406693e-24 5.597601205555511350e-23 1.384602802232411440e-21 1.979313371306395798e-21 0.000000000000000000e+00 1.336822159593629810e-21 1.586896852510283965e-20 2.471371555514003253e-21 4.040315411348909712e-20 3.560500175537139853e+02 4.193353282078960162e-20 3.625942034299734518e-20 5.592744992664669752e-21 4.374773990661448123e-26 5.691837251934848540e-21 9.455245823024017472e-24 5.584182120777932695e-23 1.384562356480901367e-21 2.052385861107949551e-21 0.000000000000000000e+00 1.347394930649530393e-21 1.717104661654428739e-20 2.472849448233759715e-21 4.107711259595065804e-20 3.564500175340155579e+02 4.259836896772162253e-20 3.628106680861232898e-20 7.206764599447251390e-21 4.351934724866266880e-26 5.688846597876519300e-21 9.421645767010052834e-24 5.571330238700159063e-23 1.384521919776407898e-21 1.913513553667782432e-21 0.000000000000000000e+00 1.351731991132844824e-21 1.634705840669261136e-20 2.474327340953680181e-21 4.100455659926892276e-20 3.568500175143613546e+02 4.318529959895677105e-20 3.630272473014647207e-20 6.479038364542278502e-21 4.329363297403897581e-26 5.685855943817859041e-21 9.392446108714398126e-24 5.559648103507797457e-23 1.384481492119723788e-21 1.760533530094432586e-21 0.000000000000000000e+00 1.359620076634827324e-21 1.666879913876257096e-20 2.475805233673763525e-21 4.102488523217785855e-20 3.572500174947511482e+02 4.144940587009933944e-20 3.632439400970252855e-20 6.815676530563683551e-21 4.306791869939045279e-26 5.682865289758870020e-21 9.363248686877608113e-24 5.547965968314152211e-23 1.384441073511641790e-21 1.684009052495408107e-21 0.000000000000000000e+00 1.374483665484346765e-21 1.655919829404721379e-20 2.477283126394009744e-21 4.105117439318080689e-20 3.576500174751848249e+02 4.181235825520840036e-20 3.634607462696578333e-20 6.288798629522036311e-21 4.284384740668276780e-26 5.679874635699552989e-21 9.334053522487016242e-24 5.536283833119223326e-23 1.384400663952954658e-21 1.613273050510940281e-21 0.000000000000000000e+00 1.393583299270884374e-21 1.777315278884886130e-20 2.478761019114417712e-21 4.148904388908809801e-20 3.580500174556622142e+02 4.244489466531706056e-20 3.636776656165934179e-20 5.745887494570965383e-21 4.262099027470250711e-26 5.676883981639908701e-21 9.304860636791723854e-24 5.524601697923019029e-23 1.384360263444454204e-21 1.569840863728285183e-21 0.000000000000000000e+00 1.429271335736512600e-21 1.857205751117334936e-20 2.480257229618657130e-21 4.177746383614320243e-20 3.584500174361832023e+02 4.237955455347587902e-20 3.638946979354406958e-20 6.045692566828392703e-21 4.239813314269796167e-26 5.673893327579938659e-21 9.275670051306665933e-24 5.512919562725541672e-23 1.384319871986933558e-21 1.680939743645304592e-21 0.000000000000000000e+00 1.596268186025022565e-21 1.721739076002371490e-20 2.481757912204883499e-21 4.126533339497308497e-20 3.588500174167475620e+02 4.163696916009742182e-20 3.641118430241858056e-20 6.926677387386055597e-21 4.217899935511817487e-26 5.670922094821939282e-21 9.246481787816767942e-24 5.501237427526797132e-23 1.384279593401600171e-21 1.767548130306356824e-21 0.000000000000000000e+00 1.750747867630375712e-21 2.113453268857365724e-20 2.483258594791272744e-21 4.320713240767488647e-20 3.592500173973552364e+02 4.253795323515132354e-20 3.643291006811917063e-20 6.276475735609668354e-21 4.196094626834443449e-26 5.667996169037864599e-21 9.217295868381136464e-24 5.489555292326787760e-23 1.384239566067197443e-21 1.976323496556252803e-21 0.000000000000000000e+00 1.889835491155122809e-21 2.366654245760036612e-20 2.484759277377824113e-21 4.443594350559544649e-20 3.596500173780059981e+02 4.139023691238101712e-20 3.645464707051970935e-20 6.788498343298690378e-21 4.174289318154720145e-26 5.665070243253474695e-21 9.188112315337390895e-24 5.477873157125519433e-23 1.384199547787634095e-21 1.803276869944176403e-21 0.000000000000000000e+00 2.017331574263692758e-21 2.123045572572783070e-20 2.486259959964537606e-21 4.328131571747332653e-20 3.601000277700628089e+02 4.334336216502455702e-20 3.647911517096203460e-20 6.292138996456635889e-21 4.150062222637331231e-26 5.661751646147683088e-21 9.155282915241343477e-24 5.464730450884808810e-23 1.384181382089702423e-21 1.498348939609656757e-21 0.000000000000000000e+00 2.088326246675793630e-21 1.850459454784031239e-20 2.487948266944205395e-21 4.194648231703556034e-20 3.605500173346272845e+02 4.126485724301117699e-20 3.650359630611376331e-20 6.146179469687976423e-21 4.125850394738640693e-26 5.658418390113871767e-21 9.122458090741856023e-24 5.451588352918080389e-23 1.384178036227909636e-21 1.356122850955482546e-21 0.000000000000000000e+00 1.777567898818107003e-21 2.354347826653501246e-20 2.489636495785231936e-21 4.438149663608851304e-20 3.609500173154172558e+02 4.131475954921983828e-20 3.652536968924724578e-20 7.002866774447740030e-21 4.104487582301888740e-26 5.655460984452040453e-21 9.093282386190229415e-24 5.439906217712746027e-23 1.384169516599115207e-21 1.530407657509072766e-21 0.000000000000000000e+00 1.513639663150186626e-21 2.405363263580251779e-20 2.491137178372467161e-21 4.479355132370349946e-20 3.613500172962498027e+02 4.259603368478242217e-20 3.654715422396343867e-20 7.631709565063093653e-21 4.083390238180101171e-26 5.652535058666321206e-21 9.064109146175725574e-24 5.428224082506169168e-23 1.384129537022995446e-21 1.527494995857377862e-21 0.000000000000000000e+00 1.440830777273724439e-21 2.582688180669261824e-20 2.492637860959862629e-21 4.588526746457555706e-20 3.617500172771246980e+02 4.300960381968107381e-20 3.656894989033296336e-20 6.483272448621167918e-21 4.062292894056080277e-26 5.649609132880292004e-21 9.034938394571883920e-24 5.416541947298355689e-23 1.384089566505195657e-21 1.521287746287593123e-21 0.000000000000000000e+00 1.399595514915963130e-21 2.961191065240695995e-20 2.494138543547416836e-21 4.796370381970636087e-20 3.621500172580418280e+02 4.252257223892638079e-20 3.659075666846377418e-20 6.155719315257885612e-21 4.041397702100782115e-26 5.646678772418041949e-21 9.005770155559518093e-24 5.404859812089307941e-23 1.384049757914841860e-21 1.538527219607726374e-21 0.000000000000000000e+00 1.373216566216575600e-21 2.717875899134056431e-20 2.495670104998405425e-21 4.647306779665269947e-20 3.625500172390011357e+02 4.361509883270284315e-20 3.661257453850108619e-20 7.072325787962026207e-21 4.020667878526153410e-26 5.643742992741276520e-21 8.976604453631617771e-24 5.393177676879029450e-23 1.384010145191911166e-21 1.379381694231212880e-21 0.000000000000000000e+00 1.346636702211739249e-21 3.179255668677813968e-20 2.497215696412622021e-21 4.944681573002052930e-20 3.629500172200023371e+02 4.333301952879323848e-20 3.663440348062728487e-20 6.193041008008707198e-21 3.999938054949353944e-26 5.640807213064203393e-21 8.947441313598407696e-24 5.381495541667527270e-23 1.383970541531074061e-21 1.438646400339309627e-21 0.000000000000000000e+00 1.331245591768298526e-21 2.892344594734580216e-20 2.498761287827000742e-21 4.754809968467907707e-20 3.633500172010454321e+02 4.443770897806198617e-20 3.665624347506198036e-20 6.744076183096436030e-21 3.979463685659056409e-26 5.637898040469487207e-21 8.918280760592415534e-24 5.369813406454800224e-23 1.383930946933108630e-21 1.240849933341706884e-21 0.000000000000000000e+00 1.325399335612292211e-21 2.986796965879930668e-20 2.500306879241540834e-21 4.821317672026198960e-20 3.637500171821301933e+02 4.484502107120686030e-20 3.667809450206183284e-20 7.103257714242324749e-21 3.959098774341372741e-26 5.634998958037772048e-21 8.889122820073732203e-24 5.358131271240857718e-23 1.383891361398792390e-21 1.349846935923946376e-21 0.000000000000000000e+00 1.298545500179415064e-21 3.504460321692398803e-20 2.501852470656242298e-21 5.164592909971253087e-20 3.642000274574399441e+02 4.471169035741884486e-20 3.670269063319996322e-20 7.798395388658727186e-21 3.936187724886128341e-26 5.631737415675435658e-21 8.856322541403209024e-24 5.344988568409783658e-23 1.383846837488942521e-21 1.496737647549373471e-21 0.000000000000000000e+00 1.286333448667126484e-21 3.285805900704439793e-20 2.503591300783583744e-21 5.031254110565063737e-20 3.646500171397226495e+02 4.561250503398511163e-20 3.672729954861560045e-20 7.133675270859311873e-21 3.913586507826558794e-26 5.628476022565313056e-21 8.823527139960772970e-24 5.331846467005053995e-23 1.383802597133829646e-21 1.392381115435028105e-21 0.000000000000000000e+00 1.293072272213434911e-21 3.341723615499762395e-20 2.505330051339907023e-21 5.059625025295736422e-20 3.650500171209419591e+02 4.694075235125700944e-20 3.674918629554756282e-20 7.237370854415973039e-21 3.893502298243232149e-26 5.625576940132622895e-21 8.794377869919441131e-24 5.320164331787181810e-23 1.383763311706730539e-21 1.198102987505916882e-21 0.000000000000000000e+00 1.307810357974357056e-21 3.908185992548996517e-20 2.506875642755128338e-21 5.452769089429508585e-20 3.654500171022023665e+02 4.683150413094199168e-20 3.677108399154843298e-20 6.437635906478765062e-21 3.873538292278155204e-26 5.622691695356910565e-21 8.765231324350420005e-24 5.308482196568109446e-23 1.383743295149245012e-21 1.266187690283566014e-21 0.000000000000000000e+00 1.331246841579850809e-21 3.564635031239179237e-20 2.508421234170508392e-21 5.203285494105563602e-20 3.658500170835038148e+02 4.676758064385886457e-20 3.679299261706890253e-20 6.862023737891945804e-21 3.853934814933676074e-26 5.619818968218472474e-21 8.736087530523031784e-24 5.296800061347838078e-23 1.383740710152759160e-21 1.238185677075701681e-21 0.000000000000000000e+00 1.343817415423542430e-21 3.787386562184591493e-20 2.509966825586047184e-21 5.365053812070720421e-20 3.662500170648460198e+02 4.667981191775106624e-20 3.681491215259641826e-20 6.873236428686262833e-21 3.834331337587200671e-26 5.616946241079741732e-21 8.706946516069118181e-24 5.285117926126375934e-23 1.383738132711700806e-21 1.171316612613407603e-21 0.000000000000000000e+00 1.360960102400134759e-21 3.538719035744711997e-20 2.511511978783480920e-21 5.194065796641133872e-20 3.666500170462289816e+02 4.522950824507351807e-20 3.683684257865520020e-20 6.669352853755292810e-21 3.814832219923060678e-26 5.614073513940719092e-21 8.677808308989023691e-24 5.273435790903724190e-23 1.383707388329822122e-21 1.394424604485129351e-21 0.000000000000000000e+00 1.374091691089518560e-21 3.252702538576781440e-20 2.513056599090978358e-21 5.003023030425722422e-20 3.671000272405329383e+02 4.554292756359358596e-20 3.686152786186706945e-20 6.671604749362639277e-21 3.793090857839992106e-26 5.610841622545263463e-21 8.645030473044362574e-24 5.260293090438451824e-23 1.383663608891160143e-21 1.336507717629624275e-21 0.000000000000000000e+00 1.369072667513599412e-21 3.321044397242540726e-20 2.514794336383614166e-21 5.049356245100198131e-20 3.675500170044888364e+02 4.305605166213816135e-20 3.688622575516314785e-20 5.940135680449285314e-21 3.771350482809218515e-26 5.607609877876852870e-21 8.612257755109837446e-24 5.247150986648429007e-23 1.383619840833503755e-21 1.247479351491029502e-21 0.000000000000000000e+00 1.366030157086381932e-21 3.123116832254197614e-20 2.516531994783420201e-21 4.913636569177004027e-20 3.679500169860031633e+02 4.746168687212823306e-20 3.690819144138682897e-20 6.108547815405299118e-21 3.752357129177989601e-26 5.604737150736886073e-21 8.583128869942400973e-24 5.235468851421940449e-23 1.383580942896827949e-21 1.264191730727797449e-21 0.000000000000000000e+00 1.357026983331515472e-21 2.665944334282433147e-20 2.518076615091425076e-21 4.640436912059822371e-20 3.683500169675576785e+02 4.361394797062525602e-20 3.693016793577829889e-20 6.712472459398673604e-21 3.733474371428054021e-26 5.601864423596631138e-21 8.554002915405949066e-24 5.223786716194278161e-23 1.383542052383616388e-21 1.191693039251055059e-21 0.000000000000000000e+00 1.344987996622709803e-21 2.664341672871329745e-20 2.519621235399585305e-21 4.649345907804435159e-20 3.687500169491521547e+02 4.155214412475228565e-20 3.695215521905376273e-20 7.077028526137606647e-21 3.714591613676232943e-26 5.599005284776304218e-21 8.524879921538751391e-24 5.212104580965449193e-23 1.383503341246050883e-21 1.179172775200749381e-21 0.000000000000000000e+00 1.347490393650245383e-21 2.719756366990234551e-20 2.521165855707899758e-21 4.688370468180290471e-20 3.691500169307865917e+02 4.257925557883603440e-20 3.697415327196587987e-20 6.628912458147081375e-21 3.695943350357550170e-26 5.596158438060167710e-21 8.495759918787871936e-24 5.200422445735452373e-23 1.383464793082873660e-21 1.180981625357671636e-21 0.000000000000000000e+00 1.334982724994621686e-21 2.473278727124211877e-20 2.522710476016368437e-21 4.544794783154267252e-20 3.696000270562760761e+02 4.341138947249055444e-20 3.699891448908400454e-20 6.608438891898097150e-21 3.675010120727022756e-26 5.592955663293170652e-21 8.463002790944578990e-24 5.187279747279930339e-23 1.383421434298866883e-21 1.153464440539563306e-21 0.000000000000000000e+00 1.331551174413502025e-21 2.282405304073284319e-20 2.524448213043273684e-21 4.445450093092960820e-20 3.700500168896091395e+02 4.047217918127146889e-20 3.702368816805396841e-20 6.360509451692507553e-21 3.654133019093432308e-26 5.589789070505449167e-21 8.430251009412041025e-24 5.174137641463723779e-23 1.383378086869891596e-21 1.205216718481096253e-21 0.000000000000000000e+00 1.337515607681893594e-21 2.365337562751412411e-20 2.526185871710982969e-21 4.487178489929784528e-20 3.704500168713722701e+02 4.073252227192887908e-20 3.704572108979724693e-20 6.243688555824160736e-21 3.635801985446425212e-26 5.586978259822789154e-21 8.401140943137014242e-24 5.162455506229968903e-23 1.383339562845180348e-21 1.231951056622935903e-21 0.000000000000000000e+00 1.313189811268767683e-21 2.420862658908018916e-20 2.527724938241224052e-21 4.516845086475160942e-20 3.708500168531747931e+02 3.967293516549507480e-20 3.706776469978093345e-20 6.041390373534998261e-21 3.617470951797612400e-26 5.584159339513440429e-21 8.372034002102669552e-24 5.150773370995063806e-23 1.383309153476750945e-21 1.222407402327948658e-21 0.000000000000000000e+00 1.294361965920378090e-21 2.108659124070615126e-20 2.529253384375144290e-21 4.356406530567268233e-20 3.712500168350164813e+02 3.965273331675181594e-20 3.708981897894799331e-20 6.409720749648595419e-21 3.599260783907468209e-26 5.581312492795828629e-21 8.342930219019214952e-24 5.139091235759014364e-23 1.383306669764284221e-21 1.121621236370618976e-21 0.000000000000000000e+00 1.292296333738059621e-21 1.783841163368318583e-20 2.530781830509213862e-21 4.215860931523407342e-20 3.717000269034157895e+02 3.956578555601364602e-20 3.711464332902553360e-20 6.883215402959695393e-21 3.579091101867417347e-26 5.578109718435148623e-21 8.310191545177246908e-24 5.125948538970829975e-23 1.383303884559800686e-21 1.149298664711301266e-21 0.000000000000000000e+00 1.293575537213097162e-21 1.877073226628372230e-20 2.532501370960617238e-21 4.265741572206727808e-20 3.721500167943029851e+02 4.124913869742505408e-20 3.713948001781128348e-20 7.596494958344467105e-21 3.558922324193806963e-26 5.574949883039675482e-21 8.277458425870871181e-24 5.112806431473735847e-23 1.383276114796052818e-21 1.145017590471205257e-21 0.000000000000000000e+00 1.303935760096850522e-21 1.555161096678918932e-20 2.534220834311416486e-21 4.148891545821166346e-20 3.725500167762712636e+02 4.173696230130018876e-20 3.716156884064739154e-20 7.739249337617109359e-21 3.541165071515687593e-26 5.572164168879539659e-21 8.248365137578790328e-24 5.101124296233989477e-23 1.383237951612306041e-21 1.315102770755052605e-21 0.000000000000000000e+00 1.346329959278796069e-21 1.674400896354602100e-20 2.535749280445969798e-21 4.200210911595854394e-20 3.729500167582781955e+02 4.151157094827624741e-20 3.718366825207639460e-20 7.369819851837294036e-21 3.523510371455142719e-26 5.569378454719133755e-21 8.219275151421992497e-24 5.089442160993114043e-23 1.383199795860958018e-21 1.077416234822184997e-21 0.000000000000000000e+00 1.390764706434133752e-21 1.824713242821719544e-20 2.537277726580670939e-21 4.257186838162572461e-20 3.733500167403237242e+02 4.206979802930830369e-20 3.720577827216495397e-20 6.755177475601620153e-21 3.505855671392894296e-26 5.566592740558460025e-21 8.192453765073576330e-24 5.078441738951244003e-23 1.383161647542623768e-21 1.219093429354285806e-21 0.000000000000000000e+00 1.380539209960639868e-21 2.342428786571063201e-20 2.538806172715519911e-21 4.495931463800862267e-20 3.738000267522730269e+02 4.120717992476437302e-20 3.723066526325162741e-20 7.114630138871435577e-21 3.486208067388334622e-26 5.563458742260955710e-21 8.165384978885150058e-24 5.067000217869663587e-23 1.383118738613570878e-21 1.115970132148450635e-21 0.000000000000000000e+00 1.388997767947512161e-21 1.607125929825512400e-20 2.540525712951221391e-21 4.168359957067226308e-20 3.742500167000664533e+02 3.948979814587475839e-20 3.725556447042558421e-20 6.926899431263828209e-21 3.466639273761214452e-26 5.560324883695965748e-21 8.138318207116109376e-24 5.055559206919982659e-23 1.383075841006513385e-21 1.110832717366632064e-21 0.000000000000000000e+00 1.396368441970103478e-21 1.383936171818476432e-20 2.542245176519465277e-21 4.086522349005833979e-20 3.746500166822364122e+02 3.841616684942780555e-20 3.727770875799027893e-20 6.450929670029582778e-21 3.449254206117816220e-26 5.557539169534425350e-21 8.114259002515973108e-24 5.045389192682287948e-23 1.383037716849720911e-21 1.157288175025222548e-21 0.000000000000000000e+00 1.416584369286430198e-21 1.234823290681918567e-20 2.543772129913527271e-21 4.032789815999945488e-20 3.750500166644443993e+02 3.887760998020338778e-20 3.729986353492585375e-20 7.000612399136044534e-21 3.432250817043618844e-26 5.554753455372619385e-21 8.090200448111755019e-24 5.035219178443626393e-23 1.382999685130250432e-21 1.202651677778768388e-21 0.000000000000000000e+00 1.422162749764317997e-21 1.132427111312923097e-20 2.545287311190510314e-21 4.014032249804246391e-20 3.755000266311574819e+02 3.909991090250191977e-20 3.732480072735380168e-20 6.528206002203544086e-21 3.413121579814527250e-26 5.551619457390153574e-21 8.063134758204787682e-24 5.023777658512178449e-23 1.382957097541389258e-21 1.239964403103947196e-21 0.000000000000000000e+00 1.419318659211317999e-21 1.068324935511848440e-20 2.546991927956379754e-21 3.990820495297626084e-20 3.759500166245508126e+02 3.937029634134777118e-20 3.734975003809501044e-20 6.616292671833600572e-21 3.394076931141687897e-26 5.548485598507592810e-21 8.036071108228861384e-24 5.012336646403118610e-23 1.382914519351928367e-21 1.182943738175755494e-21 0.000000000000000000e+00 1.416700306569513827e-21 9.416511364254580542e-21 2.548696469064245962e-21 3.962389196147387661e-20 3.763500166068815815e+02 3.866674139665494852e-20 3.737193877666234080e-20 6.188471186517336882e-21 3.377331169169535351e-26 5.545699885368428562e-21 8.012014707503165139e-24 5.002166632161334942e-23 1.382876677550206423e-21 1.161038460905637737e-21 0.000000000000000000e+00 1.407692638535172594e-21 9.711202030862211400e-21 2.550211650341693561e-21 3.964554600778645626e-20 3.767500165892498103e+02 3.836340842610398962e-20 3.739413792545639816e-20 7.000267172625068871e-21 3.360585407195814713e-26 5.542938823543231449e-21 7.987958982184850651e-24 4.991996617918599711e-23 1.382839157639717854e-21 1.239001462509231598e-21 0.000000000000000000e+00 1.379751159350648242e-21 9.390733936859810024e-21 2.551726831619283347e-21 3.972531049604521551e-20 3.772000265111337853e+02 3.851178746700096000e-20 3.741912494041553111e-20 7.442733848407341183e-21 3.341930679308877571e-26 5.539832560365625229e-21 7.960896508290203912e-24 4.980555099126932836e-23 1.382796953903286901e-21 1.066524734665357997e-21 0.000000000000000000e+00 1.360117885745552540e-21 9.690009618204887147e-21 2.553431448215342565e-21 3.989477796481117562e-20 3.776500165497149624e+02 3.790190747160906073e-20 3.744412397671623275e-20 7.342025302455730930e-21 3.323507557729318870e-26 5.536736728870371450e-21 7.933836101498596819e-24 4.969114085868970092e-23 1.382769801233178236e-21 1.271739232310493085e-21 0.000000000000000000e+00 1.336826971270024140e-21 9.518750837753995226e-21 2.555135989494378054e-21 3.986323567489378492e-20 3.780500165322043813e+02 3.718302289315486101e-20 3.746635683096272873e-20 8.139101676752549816e-21 3.307131087857987216e-26 5.533999886884917473e-21 7.909782613908517826e-24 4.958944071623153303e-23 1.382767689454175762e-21 1.234746871843607297e-21 0.000000000000000000e+00 1.382013487791051735e-21 9.028087683597293386e-21 2.556651170772426753e-21 3.992480415416795935e-20 3.784500165147308053e+02 3.663430466858639460e-20 3.748860001693045503e-20 7.456884961417745818e-21 3.290831871147044691e-26 5.531263044899209965e-21 7.885729828254477015e-24 4.948774057376395530e-23 1.382765583719786232e-21 1.288613638704897237e-21 0.000000000000000000e+00 1.381963448378353033e-21 8.904294769835290520e-21 2.558166352050615760e-21 3.978581048346607373e-20 3.789000263921870442e+02 3.900167410658538148e-20 3.751363647866678529e-20 7.340396311594278769e-21 3.272541639178569304e-26 5.528191855557663352e-21 7.858670696349918656e-24 4.937332539714305846e-23 1.382738447354895948e-21 1.096506550866164313e-21 0.000000000000000000e+00 1.367320441946329517e-21 9.764714812725740364e-21 2.559870968478384812e-21 3.998254865202681119e-20 3.793500164755499782e+02 3.915973040531920638e-20 3.753868486557020069e-20 7.054763277848001030e-21 3.254252211722563661e-26 5.525125551449791918e-21 7.831613660485744210e-24 4.925891525317765739e-23 1.382696281550949234e-21 1.222408094010593144e-21 0.000000000000000000e+00 1.339594409165832822e-21 9.854816117277554333e-21 2.561574894017601703e-21 3.997914152227020560e-20 3.797500164581958302e+02 3.803941874502341371e-20 3.756096150287999698e-20 6.592598223474689916e-21 3.238454684331812839e-26 5.522399887391291117e-21 7.807563201029652363e-24 4.915721511067971664e-23 1.382658806334326156e-21 1.164181700296957938e-21 0.000000000000000000e+00 1.319485508450781899e-21 1.204979234100719096e-20 2.563089463857306809e-21 4.051620154627438937e-20 3.802000263019454565e+02 3.854865869222829445e-20 3.758603552521020453e-20 6.193808889767193091e-21 3.220709296159952202e-26 5.519320872670899050e-21 7.780506713891311670e-24 4.904279994262873786e-23 1.382617002118617520e-21 1.119149418181476352e-21 0.000000000000000000e+00 1.309320967202436885e-21 7.646379100400533224e-20 2.564793392273516595e-21 8.567208792911228620e-20 3.806500164192824514e+02 4.032320641931411867e-20 3.761112139969693146e-20 6.890063160712906938e-21 3.202986583917175753e-26 5.516241992920699132e-21 7.753452346183282709e-24 4.892838979002541638e-23 1.382575207253652542e-21 1.172755181846918476e-21 0.000000000000000000e+00 1.300975101705872319e-21 1.109199463450002898e-20 2.566497245997148949e-21 4.033732094910617687e-20 3.810500164020466514e+02 4.026032388887042718e-20 3.763343129541683361e-20 6.992522052150728626e-21 3.187322719045905490e-26 5.513528585829774746e-21 7.729404283742533974e-24 4.882668964749738298e-23 1.382538183786152755e-21 1.227606031982036152e-21 0.000000000000000000e+00 1.289416920015116137e-21 1.007944054799140995e-20 2.568011815837302060e-21 4.011038254384447874e-20 3.815000262123189145e+02 3.994532192519865997e-20 3.765854266173557390e-20 6.051643855950248535e-21 3.169700486139445696e-26 5.510515476665342829e-21 7.702350522075114363e-24 4.871227448795803536e-23 1.382496744465973733e-21 1.107700279940844323e-21 0.000000000000000000e+00 1.306651437546600910e-21 9.784195155993528348e-21 2.569715744126752178e-21 3.990408488852418007e-20 3.819500163633979923e+02 3.906324840083259628e-20 3.768366580766105258e-20 7.392798380410247985e-21 3.152248707160638332e-26 5.507502499132031047e-21 7.675298904380754836e-24 4.859786432677577392e-23 1.382455314477460189e-21 1.265830398242783683e-21 0.000000000000000000e+00 1.315671593567754893e-21 9.669144509779206837e-21 2.571419597978146662e-21 4.012974204220695224e-20 3.823500163462792329e+02 4.036658926268872584e-20 3.770600877005512904e-20 8.319690886053011971e-21 3.136942041149049299e-26 5.504778835525457553e-21 7.651253312669256951e-24 4.849616418421798875e-23 1.382418256917286012e-21 1.263777458186714622e-21 0.000000000000000000e+00 1.317840311671765890e-21 1.071518665992478883e-20 2.572934167818743264e-21 4.059489483213996158e-20 3.828000261233011088e+02 3.745835867424825017e-20 3.773115726510045988e-20 7.655829567582015794e-21 3.119721667015011948e-26 5.501699821261623731e-21 7.624202360489997572e-24 4.838174903313256140e-23 1.382376496159216460e-21 1.190938097319099523e-21 0.000000000000000000e+00 1.338803395754301890e-21 1.109024652164869389e-20 2.574638095982293234e-21 4.058653812380944775e-20 3.832500163078927358e+02 3.775334930245200326e-20 3.775631746766115554e-20 6.712538029264149190e-21 3.102747158329436456e-26 5.498631195155848411e-21 7.597153578037067772e-24 4.826733886342972916e-23 1.382334798135112611e-21 1.200342062693189412e-21 0.000000000000000000e+00 1.325098146171416539e-21 1.012082963091490875e-20 2.576341949960580171e-21 4.018720311127541847e-20 3.836500162908898233e+02 3.928606721512151590e-20 3.777869330618358513e-20 6.415295986563844791e-21 3.087778563924388893e-26 5.495952934400129231e-21 7.573110533814434338e-24 4.816563872084248610e-23 1.382297996307256237e-21 1.253532343944346482e-21 0.000000000000000000e+00 1.325514036873966827e-21 1.063756218525863698e-20 2.577844532179403059e-21 4.029436259185576603e-20 3.841000260348859001e+02 4.165328783506626131e-20 3.780387871603015368e-20 5.686281769274458579e-21 3.070938529868073808e-26 5.492939825679459408e-21 7.546062478624339928e-24 4.805122357815387939e-23 1.382256600459624952e-21 1.195554229983413235e-21 0.000000000000000000e+00 1.318561907972748933e-21 1.080636162752683315e-20 2.579531086818296439e-21 4.025110956374710510e-20 3.845500162527626458e+02 3.787145170884708641e-20 3.782907576175681583e-20 7.134043978470338825e-21 3.054196062605657439e-26 5.489939547287696350e-21 7.519016620185679522e-24 4.793681339998829303e-23 1.382234341153734936e-21 1.176334141084564963e-21 0.000000000000000000e+00 1.302334886843327751e-21 1.112068037508371726e-20 2.581217568276847313e-21 4.058815065096425110e-20 3.849500162358744433e+02 3.837923777209564946e-20 3.785148428704581502e-20 7.483601975545104302e-21 3.039329396566668430e-26 5.487284374986005614e-21 7.494976203415755701e-24 4.783511325737188008e-23 1.382232332922117813e-21 1.142975312964589295e-21 0.000000000000000000e+00 1.308393313081844790e-21 1.223734470566031217e-20 2.582716695431481392e-21 4.099028760902305298e-20 3.854000259470670926e+02 3.975633964788804645e-20 3.787670639909814714e-20 6.805175162411862983e-21 3.022629139972671788e-26 5.484297241558261827e-21 7.467931136381483765e-24 4.772069812302356448e-23 1.382230080841306626e-21 1.344945115880657840e-21 0.000000000000000000e+00 1.290565224919653359e-21 1.146101533501661251e-20 2.584403249947433485e-21 4.067498192418777717e-20 3.858500161980040843e+02 3.859974752535584798e-20 3.790194007584900860e-20 6.963698452950624584e-21 3.006280733831191800e-26 5.481289456761190093e-21 7.440888294460788389e-24 4.760628793645239418e-23 1.382196538180235963e-21 1.362867923907951611e-21 0.000000000000000000e+00 1.299167646031406330e-21 1.059243982072825652e-20 2.586089731529888235e-21 4.049000330659401265e-20 3.862500161812294550e+02 4.031294176259649732e-20 3.792438109972083706e-20 7.603456830644067231e-21 2.991748503035665141e-26 5.478611196003941454e-21 7.416850588480127164e-24 4.750458779380711109e-23 1.382159943528821947e-21 1.330860314762885252e-21 0.000000000000000000e+00 1.301895323813963304e-21 9.845048259009806179e-21 2.587588858684948125e-21 4.043619428124557764e-20 3.867000258598388314e+02 3.865400233532644790e-20 3.794963970270650027e-20 6.696974295002127589e-21 2.975498098157199162e-26 5.475601552482104041e-21 7.389808604627405284e-24 4.739017266774309780e-23 1.382118846944292637e-21 1.400378267396883158e-21 0.000000000000000000e+00 1.307736358418651666e-21 1.005378399971387102e-20 2.589275413078784222e-21 4.035311062524184269e-20 3.871500161436132430e+02 3.919802268716263218e-20 3.797490979966051236e-20 7.349771949902780474e-21 2.959519754638259041e-26 5.472614548012221918e-21 7.362768875656810982e-24 4.727576247282300238e-23 1.382078050549853752e-21 1.331785213754242098e-21 0.000000000000000000e+00 1.347086372536254229e-21 1.233888154008029151e-20 2.590961894784307400e-21 4.111598516023690173e-20 3.876000257997927179e+02 3.831296174631738492e-20 3.800019354252915273e-20 8.287555724555978799e-21 2.943540723240148846e-26 5.469627414949651751e-21 7.335729084108573610e-24 4.716134735246180589e-23 1.382037258558654393e-21 1.305248683031341693e-21 0.000000000000000000e+00 1.405027090281077352e-21 1.213773672502272101e-20 2.592648449094080417e-21 4.125835275725042492e-20 3.880500161061715403e+02 3.915542280137420604e-20 3.802548873066224453e-20 7.627930115546006519e-21 2.927693534908689398e-26 5.466675963754783290e-21 7.308691568913956936e-24 4.704693715179453051e-23 1.381996658653535307e-21 1.228794463336137809e-21 0.000000000000000000e+00 1.369872277245597363e-21 1.102026985836623857e-20 2.594326627003080349e-21 4.083482830906244876e-20 3.884500160895865406e+02 3.866833306959085796e-20 3.804798432671624041e-20 7.337351187533892248e-21 2.913700092865941156e-26 5.464077673264224098e-21 7.284658650323521777e-24 4.694523700910102865e-23 1.381960705189798050e-21 1.471687157394933320e-21 0.000000000000000000e+00 1.350777945973621101e-21 1.102360174188311014e-20 2.595813322019825064e-21 4.081056918523405645e-20 3.889000257135502352e+02 3.933798806485578778e-20 3.807330420597529711e-20 7.861513721545152301e-21 2.897957133234162056e-26 5.461154533826511171e-21 7.257622112144215970e-24 4.683082189693070619e-23 1.381920262496201301e-21 1.474822387781177072e-21 0.000000000000000000e+00 1.358108172611033774e-21 1.055844894685255845e-20 2.597485889752758777e-21 4.080886405431519884e-20 3.893500160523947216e+02 3.882501907289117716e-20 3.809863546052706804e-20 8.675809539168220259e-21 2.882377151241993648e-26 5.458177479652207339e-21 7.230587882637897273e-24 4.671641168800902131e-23 1.381879547761365091e-21 1.271560210741620520e-21 0.000000000000000000e+00 1.337761924462974413e-21 1.081508928724696680e-20 2.599158385807963160e-21 4.105615027307154479e-20 3.898000256541807858e+02 3.900542618632854619e-20 3.812398023551278784e-20 8.293319562800498974e-21 2.866855508583668242e-26 5.455190346950696375e-21 7.203553658887645274e-24 4.660199658147736893e-23 1.381838785897539574e-21 1.335576635359297183e-21 0.000000000000000000e+00 1.337896946605657143e-21 1.074153298038044426e-20 2.600830953458468577e-21 4.098300144894208585e-20 3.902500160153744559e+02 4.041897157370267668e-20 3.814933633761008198e-20 7.597961770948485932e-21 2.851342549856004380e-26 5.452227015494198550e-21 7.176521767127046985e-24 4.648758636687339726e-23 1.381798207259350119e-21 1.444264016124676752e-21 0.000000000000000000e+00 1.340481346108111546e-21 1.050813316219581539e-20 2.602503449596738845e-21 4.081440823940811684e-20 3.906500159989757321e+02 4.054333594125381935e-20 3.817188597590024787e-20 7.358503397732935863e-21 2.837866127644267476e-26 5.449650744413376299e-21 7.152493903339207283e-24 4.638588622413254060e-23 1.381762570241953959e-21 1.505603210446752885e-21 0.000000000000000000e+00 1.328574374599707694e-21 1.006514594648941861e-20 2.603990144614175691e-21 4.068132856177548343e-20 3.911000255689074265e+02 3.959139281739574808e-20 3.819726658232763986e-20 7.605814048373359626e-21 2.822704829613397832e-26 5.446752377691782366e-21 7.128368493962094622e-24 4.628079145249281895e-23 1.381722483566316696e-21 1.435381152068763079e-21 0.000000000000000000e+00 1.329282358071528901e-21 1.091641063431246347e-20 2.605662712146286821e-21 4.096636245576371859e-20 3.915500159622012006e+02 3.748356843121140566e-20 3.822265847322810009e-20 7.169399072357967355e-21 2.807580607695299239e-26 5.443820407770128971e-21 7.105955648302489832e-24 4.618119034618848137e-23 1.381682230953906960e-21 1.226148107933034571e-21 0.000000000000000000e+00 1.341402361497198789e-21 1.015427345373209025e-20 2.607335208403864688e-21 4.070784419712073168e-20 3.920000255102032725e+02 3.828679094545606682e-20 3.824806375986593605e-20 7.856419852071449454e-21 2.792624192799099958e-26 5.440858806471311613e-21 7.083542090583026660e-24 4.608158500017110471e-23 1.381641830731673046e-21 1.549120479832704506e-21 0.000000000000000000e+00 1.346586109655702210e-21 9.181305439109044364e-21 2.609007775854468732e-21 4.063825938956339929e-20 3.924500159255953236e+02 3.893939472667083196e-20 3.827348025621023565e-20 7.633535237781678700e-21 2.777668413789971686e-26 5.437897331087962129e-21 7.061129730078594599e-24 4.598198388897552925e-23 1.381601438393173927e-21 1.504360401029531915e-21 0.000000000000000000e+00 1.358504325437364785e-21 8.729183307060322232e-21 2.610680146088990335e-21 4.051832661305278204e-20 3.929000254517680446e+02 4.023561310039086005e-20 3.829891009786535345e-20 6.839960398163538915e-21 2.762816077903134556e-26 5.434994751327595497e-21 7.038716664360788800e-24 4.588237854778987519e-23 1.381596942401389071e-21 1.403546111625714277e-21 0.000000000000000000e+00 1.359926394629688744e-21 8.833126431615114198e-21 2.612352384176076692e-21 4.041917310819538484e-20 3.933500158891569640e+02 4.102903414820882993e-20 3.832435110177640857e-20 7.787654693370217664e-21 2.748094439528720286e-26 5.432096507832548492e-21 7.016304798351200896e-24 4.578277743172549617e-23 1.381595014952657270e-21 1.425170500190530183e-21 0.000000000000000000e+00 1.376149268371305892e-21 9.986458876476380498e-21 2.614024551329128181e-21 4.088165185695295753e-20 3.937500158730155704e+02 3.942897511575990211e-20 3.834697606389415971e-20 6.752429110288352910e-21 2.735008261195005710e-26 5.429520236750069640e-21 6.996382928084809591e-24 4.569424122849143377e-23 1.381585680051386685e-21 1.529033098150526013e-21 0.000000000000000000e+00 1.384174904239652391e-21 9.063937213458181649e-21 2.615510953658276989e-21 4.050587878048976301e-20 3.942000253678327795e+02 3.861303267930325057e-20 3.837244120160281594e-20 7.447840068922073907e-21 2.720479188229353536e-26 5.426621870512263291e-21 6.973970589781432403e-24 4.559463589424602178e-23 1.381545636007716194e-21 1.428018927744804628e-21 0.000000000000000000e+00 1.390032885729424375e-21 9.021464482861722552e-21 2.617183191628846089e-21 4.063842375137002147e-20 3.946500158368171469e+02 4.025701339985348051e-20 3.839791743339788530e-20 7.149219435608339099e-21 2.706079493221853886e-26 5.423723626813719971e-21 6.951559455019385333e-24 4.549503477118829185e-23 1.381505599826230771e-21 1.441466387053361115e-21 0.000000000000000000e+00 1.384908826146741350e-21 7.897064565458960766e-21 2.618855358899306706e-21 4.037396048853316361e-20 3.951000253100472719e+02 4.018618143848899324e-20 3.842340688814251617e-20 6.893344791960202625e-21 2.691679190078489893e-26 5.420825260714949213e-21 6.929147632248618862e-24 4.539542944172097640e-23 1.381465568123886262e-21 1.541365752206221067e-21 0.000000000000000000e+00 1.348821934987000483e-21 8.091476921065662125e-21 2.620527596789657815e-21 4.039438815403194661e-20 3.955500158007833988e+02 3.875836299906654439e-20 3.844890739003447659e-20 8.194502747233332776e-21 2.677451114413997282e-26 5.417927016876310287e-21 6.906737015838817299e-24 4.529582831384870373e-23 1.381425544280423023e-21 1.555242560553018166e-21 0.000000000000000000e+00 1.322128238280172966e-21 8.035143504417697975e-21 2.622199764140948433e-21 4.064897279283334989e-20 3.960000252525244946e+02 3.989677415242453774e-20 3.847442106518678927e-20 7.827970480042191496e-21 2.663254042033262093e-26 5.415028650915943927e-21 6.884325718660653872e-24 4.519622298913778519e-23 1.381385524921539946e-21 1.682558309989868988e-21 0.000000000000000000e+00 1.287752528828358449e-21 8.990843430233214642e-21 2.623872001951446048e-21 4.080441555029600663e-20 3.964500157649133030e+02 3.927090293505057042e-20 3.849994574075516178e-20 7.482575853396845921e-21 2.649086874188434051e-26 5.412153680829124931e-21 6.861915630803519106e-24 4.509662185647289275e-23 1.381345819591157866e-21 1.423217197069898630e-21 0.000000000000000000e+00 1.282324099924563889e-21 8.498914479568400245e-21 2.625544169383198032e-21 4.064764814570108401e-20 3.969000251952625149e+02 3.991538801384037535e-20 3.852548354010701712e-20 8.201292136094659686e-21 2.635219383582793026e-26 5.409279671021853196e-21 6.839504869542009693e-24 4.499701653649685958e-23 1.381306132987188658e-21 1.597967963330110897e-21 0.000000000000000000e+00 1.289571904033355311e-21 7.582434983975470984e-21 2.627213624776393101e-21 4.063565587544919914e-20 3.973500157292056656e+02 4.115414094104183650e-20 3.855103229335074216e-20 7.334856895679324296e-21 2.621352475288800783e-26 5.406405781897509830e-21 6.817095320706251966e-24 4.489741539906111752e-23 1.381266524770416064e-21 1.477586853796549872e-21 0.000000000000000000e+00 1.306471115835735790e-21 8.261601583234188339e-21 2.628869190418303178e-21 4.062236506079984335e-20 3.978000251382596844e+02 3.932831674851562837e-20 3.857659412111263196e-20 7.414904388946955521e-21 2.607547716601332940e-26 5.403531772226240347e-21 6.794685105958206306e-24 4.479781008379858160e-23 1.381227047153574257e-21 1.550819052470935402e-21 0.000000000000000000e+00 1.320914021662772283e-21 7.647953496842410323e-21 2.630524825503862722e-21 4.054384201080769959e-20 3.982500156936595204e+02 3.895764493346800307e-20 3.860216685644848648e-20 8.082468685124434230e-21 2.593882403414950509e-26 5.400657882964863303e-21 6.772276106889704205e-24 4.469820894161360726e-23 1.381187576119658237e-21 1.701605956052002182e-21 0.000000000000000000e+00 1.342316285100522873e-21 7.762659219468027803e-21 2.632180391224714110e-21 4.072364107187741236e-20 3.987000250815141840e+02 3.952307123211207573e-20 3.862775261724790850e-20 6.860368087496175699e-21 2.580216518324579828e-26 5.397824843240535723e-21 6.749866449533762685e-24 4.459860363104333916e-23 1.381148318423463735e-21 1.656065194254505332e-21 0.000000000000000000e+00 1.383552276440308953e-21 7.901675769469916458e-21 2.633836026232278757e-21 4.054928337068372371e-20 3.991500156582735599e+02 3.997562768073243244e-20 3.865334923950892310e-20 6.076202299924314615e-21 2.566658731504457750e-26 5.395012402135790204e-21 6.727458011264805465e-24 4.449900248413063234e-23 1.381109172304589468e-21 1.613770622685144073e-21 0.000000000000000000e+00 1.366827421689096280e-21 6.794123704897222287e-21 2.635491592031714105e-21 4.024420075338912196e-20 3.996000250250242516e+02 3.952876965528932097e-20 3.867895883838887644e-20 6.939453672367364384e-21 2.553194451251276825e-26 5.392199841508179907e-21 6.705048922470823974e-24 4.439939717823153194e-23 1.381070029482298642e-21 1.451266987211156921e-21 0.000000000000000000e+00 1.377115061926247859e-21 6.144513604948494739e-21 2.637147226961635188e-21 4.029783218257072586e-20 4.000500156230468178e+02 4.080188460042863386e-20 3.870457925282274046e-20 8.106334019837167029e-21 2.539730732558441570e-26 5.389349901054036797e-21 6.682641056329703590e-24 4.429979602661242198e-23 1.381030893223953037e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.391664814629907751e-21 6.404813464532384641e-21 2.638802792839300155e-21 4.055407622970508822e-20 4.005000249687882388e+02 3.940110399392024245e-20 3.873021259524012461e-20 6.224951157856548175e-21 2.526487523135787763e-26 5.386499841864341546e-21 6.660232547568573305e-24 4.420019072536352433e-23 1.380991760267117792e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.396789399294190181e-21 6.091209779800107775e-21 2.640458427691925619e-21 4.019612890951820526e-20 4.009500155879782710e+02 3.762535728943005586e-20 3.875585670750765139e-20 7.451056168780858203e-21 2.513316369139177901e-26 5.383662402575136048e-21 6.637825265189577586e-24 4.410058956905919364e-23 1.380952633870986977e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.399809607624220042e-21 5.134298758333999284e-21 2.642113993647468498e-21 4.029551791652887688e-20 4.014000249128044402e+02 3.930868918778652259e-20 3.878151369933167133e-20 6.980803610838371216e-21 2.500144667631567555e-26 5.380849844294972547e-21 6.615417348243408423e-24 4.400098427243969249e-23 1.380913510781274447e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.406482102175821517e-21 4.586283959042895363e-21 2.643769628423144409e-21 4.016965995862459720e-20 4.019000248818106797e+02 3.859824625343828983e-20 3.881003470229625109e-20 6.154111657713512178e-21 2.485707853410608359e-26 5.377724844488683380e-21 6.590520532077787415e-24 4.389031402079135551e-23 1.380870047370952288e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.403075724367257133e-21 5.132323374747951286e-21 2.645615242213255976e-21 4.012766159392009004e-20 4.023500155337389970e+02 3.863231750798226062e-20 3.883571549131583139e-20 7.466353868073634980e-21 2.472722408883533860e-26 5.374901555325275446e-21 6.568114181647041380e-24 4.379071285724071928e-23 1.380860098786348342e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.397103750910170110e-21 4.901666877416031148e-21 2.647276537806709093e-21 4.034530765839367957e-20 4.028000248262157470e+02 4.008265856721532942e-20 3.886140908497335641e-20 6.662715497893717510e-21 2.459816623009038354e-26 5.372075050678314236e-21 6.545707209482433069e-24 4.369110756778144810e-23 1.380858484836959070e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.403644926983874438e-21 4.384416707018380796e-21 2.648937902218171830e-21 4.016937897319543653e-20 4.032500154990698320e+02 4.015127905696262420e-20 3.888711333260354894e-20 7.332780803452904973e-21 2.447131846561655191e-26 5.369251970047088049e-21 6.523301474008990415e-24 4.359150639959908788e-23 1.380853569524783154e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.392826210344314633e-21 4.752491315428455245e-21 2.650599197888879941e-21 4.035178606194959249e-20 4.037000247708687084e+02 4.140275070559239297e-20 3.891283033697364598e-20 7.372034141416559156e-21 2.434446545829056843e-26 5.366462656378912844e-21 6.500895125257493161e-24 4.349190111471667449e-23 1.380814781641201674e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.389812123421887194e-21 4.040477712354837147e-21 2.652260562224003254e-21 4.030575989731348480e-20 4.041500154645549401e+02 3.963569793769054612e-20 3.893855795033135139e-20 7.268067315311142389e-21 2.421843664890160434e-26 5.363673457864328659e-21 6.478490017550859828e-24 4.339229994192331426e-23 1.380776000294510424e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.354591991241536404e-21 3.962355043158635575e-21 2.653921857971620292e-21 4.030250657364760277e-20 4.046000247157679155e+02 3.906143712722521916e-20 3.896429827273655624e-20 8.037499672485652793e-21 2.409342620494260088e-26 5.360884144323753084e-21 6.456084305190127425e-24 4.329269466159739320e-23 1.380737222284680694e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.334133464238576669e-21 4.603289709972174367e-21 2.655583222230743851e-21 4.053995166994404782e-20 4.050500154301935254e+02 3.973646299157900858e-20 3.899004915934462510e-20 7.598967462088899069e-21 2.396842091041555701e-26 5.358094945680618342e-21 6.433679838416767313e-24 4.319309348421357472e-23 1.380698450808604599e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.308916169679743257e-21 4.445199545649640277e-21 2.657244518054927514e-21 4.046133544016745718e-20 4.055000246609117198e+02 3.859015703361612483e-20 3.901581270751261097e-20 7.435132731630952673e-21 2.384446883307303429e-26 5.355305632267075901e-21 6.411274775787699675e-24 4.309348820842397453e-23 1.380659682674181339e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.289461752485642806e-21 4.112601173638381774e-21 2.658905882238387229e-21 4.041965163392556283e-20 4.060000246305411906e+02 4.061306733908960050e-20 3.904445186237103138e-20 7.585036785897292383e-21 2.370746096737928894e-26 5.352225258418803795e-21 6.386381160481171384e-24 4.298281795663769328e-23 1.380616864261598635e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.270909556954283953e-21 3.969381778831742282e-21 2.660751804465244260e-21 4.045994455880129375e-20 4.064500153770449060e+02 3.952616684277780371e-20 3.907023876895249820e-20 7.076874724404549348e-21 2.358415641636881756e-26 5.349458921862428711e-21 6.363977717760175204e-24 4.288321677215368909e-23 1.380578412919660438e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.266446012220077544e-21 4.235835212713046046e-21 2.662428031491854772e-21 4.041936427980824720e-20 4.069000245760622079e+02 3.943225005209315730e-20 3.909603826362956718e-20 7.178901653234817810e-21 2.346351842590337900e-26 5.346692471868469947e-21 6.341573693232027095e-24 4.278361150338078512e-23 1.380539964939977072e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.257578984836006665e-21 4.471607872065076393e-21 2.664107418343508707e-21 4.048710867296090146e-20 4.073500153430707655e+02 3.917856840869112735e-20 3.912184820896439844e-20 6.993268173069020268e-21 2.334314589572858607e-26 5.343926135186040490e-21 6.319170926801502069e-24 4.268401031435822662e-23 1.380501523474309568e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.282120407719294116e-21 5.600471960402255644e-21 2.665786736408850369e-21 4.062026018775248035e-20 4.078000245218237296e+02 4.068013586528569890e-20 3.914767069542712414e-20 7.942476736772989753e-21 2.322287164970593853e-26 5.341159685316657044e-21 6.296767587838282319e-24 4.258440505007063882e-23 1.380463085375610534e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.280729148396063997e-21 4.660940948163455937e-21 2.667466123184879581e-21 4.070059691183228762e-20 4.083000244917945452e+02 4.006078402814035130e-20 3.917637520251438976e-20 8.112185881245095607e-21 2.309084040763552289e-26 5.338097411635398644e-21 6.271875906263513931e-24 4.247373479820880268e-23 1.380420536306598410e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.332163170236306212e-21 4.173675751888205344e-21 2.669332070319360365e-21 4.071017297511765018e-20 4.087500152905196273e+02 3.947933998418522279e-20 3.920222080508792973e-20 8.367395997816610887e-21 2.297201471234718393e-26 5.335353565301709056e-21 6.249474220895838498e-24 4.237413360216609200e-23 1.380382410029766704e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.362568813925806694e-21 4.343429345571613065e-21 2.671011388503064716e-21 4.080510989831624600e-20 4.092000244379269134e+02 3.953232398021260410e-20 3.922807887612975698e-20 7.963188432009397305e-21 2.285409602097515700e-26 5.332609607085811547e-21 6.227071977820572403e-24 4.227452834481657748e-23 1.380344413691939666e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.360355608458016670e-21 4.346034098959940918e-21 2.672690775162115125e-21 4.074899139734206234e-20 4.097000244081027631e+02 3.898831396436590211e-20 3.925682288895727373e-20 7.251392770756881865e-21 2.272510378060730695e-26 5.329573622442654819e-21 6.205535423835717487e-24 4.217536230352129574e-23 1.380301959207421247e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.386239264009936872e-21 3.963105716752328420e-21 2.674556722297361015e-21 4.060509039636248410e-20 4.101500152383271711e+02 4.127917549303499279e-20 3.928270398407253386e-20 8.296499014840428661e-21 2.260901312301142550e-26 5.326844169865884038e-21 6.186893134819886296e-24 4.208865335593140389e-23 1.380263695248651731e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.389264106493161319e-21 4.793225325483600998e-21 2.676236040598617811e-21 4.091836064333855475e-20 4.106000243546022830e+02 4.163496845931664898e-20 3.930859747510785304e-20 7.248087470463482900e-21 2.249345001674399557e-26 5.324115981726195781e-21 6.168250151498014838e-24 4.200194088479368660e-23 1.380225539541201557e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.385869411567347106e-21 4.819874655625866409e-21 2.677915427141486119e-21 4.074649309982464430e-20 4.111000243249810637e+02 4.002450990319182291e-20 3.933738071370622425e-20 6.327739819906904365e-21 2.236548127432517872e-26 5.321091788356969260e-21 6.147536221327048397e-24 4.190559565214772584e-23 1.380183693282484930e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.381895174175670136e-21 4.966710598522787669e-21 2.679770574669032637e-21 4.063803083488696200e-20 4.115500151864898157e+02 3.908623105633490726e-20 3.936329702875881677e-20 7.082955505955617340e-21 2.225031173820778317e-26 5.318370069436553595e-21 6.128894129686400375e-24 4.181888669852964035e-23 1.380146036665420945e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.393421864620913330e-21 5.107668270309039873e-21 2.681434511062060117e-21 4.080501258453676935e-20 4.120000242718439836e+02 3.961644453603357026e-20 3.938922566804290904e-20 7.108094146977486791e-21 2.213792011949234932e-26 5.315655951535247547e-21 6.110251348137542079e-24 4.173217423335009251e-23 1.380108225206852604e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.395375789619585836e-21 4.966692272492420986e-21 2.683098514841611041e-21 4.081682129114107101e-20 4.125000242424235353e+02 3.947986176731134965e-20 3.941804788007986887e-20 7.768977014141010945e-21 2.201361243449903247e-26 5.312647821630947818e-21 6.089537642875589269e-24 4.163582900066544622e-23 1.380066065106016662e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.398788076730079354e-21 5.009919331181018946e-21 2.684947370493413879e-21 4.096992707510388384e-20 4.129500151350039800e+02 3.905872902237400109e-20 3.944399919923704205e-20 7.252462561192233254e-21 2.190183936535443022e-26 5.309940559350382453e-21 6.070895754331389133e-24 4.154912004106013895e-23 1.380028126034635630e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.443536749202116069e-21 4.875289091283207744e-21 2.686611307001335870e-21 4.088519436145325090e-20 4.134000241896461603e+02 4.013133703448105647e-20 3.946996277141720576e-20 7.757354730492384145e-21 2.179148329872371786e-26 5.307220014981978896e-21 6.052253180329433397e-24 4.146240758179849987e-23 1.379990458251850229e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.432005310706826899e-21 4.807220077016713492e-21 2.688275310667322755e-21 4.099407341958394209e-20 4.139000241604245502e+02 3.939049649474869965e-20 3.949882371816366861e-20 6.777213816455008760e-21 2.166886792127437343e-26 5.304195821610335183e-21 6.031539706484833218e-24 4.136606234907553834e-23 1.379948639856116000e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.419974839828334310e-21 4.659181979129562427e-21 2.690124166319860606e-21 4.083000458751885474e-20 4.143500150838660261e+02 3.992893013401025529e-20 3.952480982706469509e-20 7.897177460356756976e-21 2.155903636130742309e-26 5.301489510703513082e-21 6.012898026979317318e-24 4.127935338352360499e-23 1.379920685400165944e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.411471456884371931e-21 4.394196094057015205e-21 2.691788102941897708e-21 4.102602405978770746e-20 4.148000241080031287e+02 3.923004710055590526e-20 3.955080811825729184e-20 7.915565624843230072e-21 2.145048033825403787e-26 5.298825457280621592e-21 5.994255666522700142e-24 4.119264093014000777e-23 1.379919341665489941e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.409945973072354510e-21 7.896781489333800003e-21 2.693452106495085660e-21 4.157532745676349794e-20 4.153000240789783675e+02 3.932620714616144072e-20 3.957970756261298521e-20 7.366010135810946206e-21 2.132986496064031340e-26 5.295865457452448661e-21 5.973542430857254626e-24 4.109629569737911305e-23 1.379917853468380211e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.464093882072591108e-21 4.793090004612587606e-21 2.695300962148351376e-21 4.102615476549287688e-20 4.157500150330725432e+02 4.035112486001363341e-20 3.960572824836002588e-20 6.429293694005018551e-21 2.122202103520058274e-26 5.293188619963922167e-21 5.954900966564408024e-24 4.100958672592069674e-23 1.379894746458797093e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.463182608420584571e-21 4.251401981552493636e-21 2.696959548656595697e-21 4.083334560103370295e-20 4.162000240269094888e+02 3.981043924697342409e-20 3.963176104614138050e-20 6.660275065904691830e-21 2.111484966251449747e-26 5.290503082420056279e-21 5.936258825887108027e-24 4.092287427837565065e-23 1.379857130077989169e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.492548364190629951e-21 4.836719257043553527e-21 2.698611777684846143e-21 4.096138358717025957e-20 4.167000239980794731e+02 4.079424415923276596e-20 3.966069875262481213e-20 6.540304914094917072e-21 2.099577274630355360e-26 5.287519211624364143e-21 5.915545835428548354e-24 4.082652904557722827e-23 1.379815339667081935e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.399623479977603326e-21 4.422215108232991413e-21 2.700447550920060447e-21 4.091964582965892806e-20 4.171500149826198935e+02 3.911989428996246052e-20 3.968675380377377396e-20 7.248930963060672692e-21 2.089041483457823051e-26 5.284854311302890491e-21 5.896904592765558545e-24 4.073982006825211361e-23 1.379778010692147917e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.373523871844478276e-21 4.346382324349195282e-21 2.702099713826338005e-21 4.105483582411846487e-20 4.176000239463594426e+02 3.967956054508645155e-20 3.971282089717108653e-20 6.838974261227503373e-21 2.078571045889287368e-26 5.282190258237552409e-21 5.878262678348743176e-24 4.065310762650654524e-23 1.379740697146259793e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.363417706195437940e-21 3.859549353317970444e-21 2.703751942744084835e-21 4.096037013653346905e-20 4.181000239177223534e+02 4.024943629756541396e-20 3.974179663190936707e-20 8.944441535584238026e-21 2.066937458769331945e-26 5.279236367467345268e-21 5.857549940403910640e-24 4.055676239367094784e-23 1.379699325753232875e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.374326154342924697e-21 3.902302893630583306e-21 2.705587715980007069e-21 4.139596556515991943e-20 4.186000238891537037e+02 4.014161775774902714e-20 3.977078589179357066e-20 8.657978173387331873e-21 2.055543395734715874e-26 5.276299859698621146e-21 5.836837294468711260e-24 4.046041716082216728e-23 1.379658194211661472e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.376149327675040653e-21 8.591922788138273769e-21 2.707423489216180952e-21 4.206501551976235471e-20 4.190500149146877220e+02 4.027801551210142418e-20 3.979688724608408169e-20 7.955047647000971291e-21 2.045302690880896251e-26 5.273657055262945217e-21 5.818196363312324656e-24 4.037370817559797744e-23 1.379621180820227486e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.376358782062055423e-21 4.098671214541609851e-21 2.709075652272968431e-21 4.126528874105240604e-20 4.195000238379016082e+02 4.100454484450000008e-20 3.982300054866191918e-20 9.839582190573577075e-21 2.035078253331905307e-26 5.271035576177236253e-21 5.799554766796485112e-24 4.028699574166131795e-23 1.379584169992806792e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.377327984750432263e-21 3.675495376310537560e-21 2.710727881041923255e-21 4.165491351416290115e-20 4.200000238095231566e+02 4.607670780542331617e-20 3.985202752195701011e-20 1.253687882986409176e-20 2.023866132756149353e-26 5.268138750944826643e-21 5.778842383763079056e-24 4.019065050877588548e-23 1.379543052403107874e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.367367085905413744e-21 3.387089201966194236e-21 2.712563654278795288e-21 4.237588429295816613e-20 4.205000237812121782e+02 4.052097984888502121e-20 3.988106790847631280e-20 8.115271871347076387e-21 2.012654012178880122e-26 5.265241130173833468e-21 5.758130096550432961e-24 4.009430527587745204e-23 1.379501939797066966e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.391330225861407863e-21 3.695813591522955585e-21 2.714399667121807133e-21 4.133941761794050910e-20 4.209500148473688341e+02 3.897202028604268952e-20 3.990721518270711516e-20 7.576339509541913357e-21 2.002623308371762803e-26 5.262598325499579959e-21 5.739489489868372633e-24 4.000759628282566882e-23 1.379464993697401235e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.397689973019739518e-21 3.688885796180807180e-21 2.716052612455344572e-21 4.126166016810997724e-20 4.214000237304217649e+02 4.023743054675908935e-20 3.993337431211953721e-20 7.219253237085243261e-21 1.992682203046138831e-26 5.259955416186411649e-21 5.720848224358198381e-24 3.992088385662764130e-23 1.379428136318986202e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.384959314329682359e-21 3.930511328002704510e-21 2.717705623235416223e-21 4.124459402247150496e-20 4.219000237022984834e+02 3.920875050915707908e-20 3.996245210012489771e-20 7.678860287007293038e-21 1.981636749121953108e-26 5.257018908415072476e-21 5.700136211012886622e-24 3.982453862369304377e-23 1.379387188260409081e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.392519357052484215e-21 3.793984956764217854e-21 2.719542265521098289e-21 4.134286384144695203e-20 4.224000236742417655e+02 3.971785079861010035e-20 3.999154319047084693e-20 8.147062175009143997e-21 1.970736029420157113e-26 5.254082400643342097e-21 5.679424297512795488e-24 3.972819339074561572e-23 1.379346244174140711e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.377885032588303195e-21 3.623271602616954819e-21 2.721378907807024858e-21 4.144442429070096551e-20 4.229000236462513840e+02 4.031857699813538831e-20 4.002064755414886555e-20 7.362662471471160491e-21 1.959923999950235267e-26 5.251145892871222019e-21 5.658712484954323989e-24 3.963184815778540418e-23 1.379305304060534305e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.379129953898462324e-21 4.682727902970279783e-21 2.723215550093195178e-21 4.143169669844942110e-20 4.233500147631980326e+02 4.180325784108653187e-20 4.004685229030322821e-20 7.867881695532767327e-21 1.950193364970246438e-26 5.248545584432011049e-21 5.640072307800506844e-24 3.954513915494687230e-23 1.379268674532953900e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.389876510224292534e-21 4.634182950720934255e-21 2.724868495613298805e-21 4.154440354423579698e-20 4.238000235960352597e+02 4.178580311746070009e-20 4.007306876524329918e-20 7.699102924169136167e-21 1.940588068992695258e-26 5.245958919487356701e-21 5.621431480283506757e-24 3.945842673842493240e-23 1.379232115501756582e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.424060492139298733e-21 3.800242082850797668e-21 2.726521506208913763e-21 4.145424813670992736e-20 4.243000235682293919e+02 4.149127434605173222e-20 4.010221014053057371e-20 9.762046881713136391e-21 1.929941453043418626e-26 5.243085803087441542e-21 5.600719956332613248e-24 3.936208150542917390e-23 1.379191511247037376e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.443807053424931196e-21 4.441652039408410754e-21 2.728358148495761920e-21 4.197779539249688018e-20 4.248000235404890077e+02 4.086207031820752497e-20 4.013136467956475658e-20 8.620194920389346885e-21 1.919309881766578918e-26 5.240234240745648730e-21 5.580008537639066231e-24 3.926573627242079059e-23 1.379151206186911394e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.446401948835334605e-21 5.041003860714992731e-21 2.730194790782850441e-21 4.182290807092446740e-20 4.253000235128138797e+02 4.065618378477077141e-20 4.016053235367717085e-20 6.595115343575001430e-21 1.908813641746044262e-26 5.237382678403483522e-21 5.559297225379331309e-24 3.916939103939983537e-23 1.379110905102252763e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.421266106041977527e-21 5.008573527811577680e-21 2.732029298064708108e-21 4.147610619254088303e-20 4.257500146799762888e+02 4.202787021183199919e-20 4.018679395309221692e-20 7.440672245533094004e-21 1.899367210627868266e-26 5.234792827848956806e-21 5.540657501180236428e-24 3.908268202688519824e-23 1.379074521362325068e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.436140519192001942e-21 5.756698578026282023e-21 2.733667551419935259e-21 4.174114862729327175e-20 4.262000234631622106e+02 4.141710331483857305e-20 4.021306717623556317e-20 9.147483059844994725e-21 1.889975040517745173e-26 5.232170729427244078e-21 5.522017135347873196e-24 3.899596961993059510e-23 1.379037979507715454e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.430900112561480876e-21 5.270990476222990556e-21 2.735305868908664541e-21 4.203996716755509688e-20 4.267000234356684700e+02 3.962266269496707608e-20 4.024227147664773217e-20 8.372101812490734065e-21 1.879706384365975082e-26 5.229257343760672079e-21 5.501306127512601808e-24 3.889962438687469244e-23 1.378997382018888013e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.436194890701099275e-21 5.300723193119527420e-21 2.737126186044525575e-21 4.190981977823094918e-20 4.272000234082390762e+02 4.123769909628654444e-20 4.027148880383721772e-20 7.580550115846234407e-21 1.869437728212883708e-26 5.226389710249886633e-21 5.480595230744972836e-24 3.880327915380638243e-23 1.378957016098286999e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.409341537263256111e-21 5.474854416695597708e-21 2.738946503180620955e-21 4.180834678056278900e-20 4.277000233808738017e+02 4.194375253789896508e-20 4.030071912947144170e-20 7.916332688421650958e-21 1.859261020034284124e-26 5.223538147905954234e-21 5.459884446308956419e-24 3.870693392072572385e-23 1.378916734100032717e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.379948246936880055e-21 5.939130785336428289e-21 2.740766820316949553e-21 4.196062332924585200e-20 4.282000233535725329e+02 4.174599153480761035e-20 4.032996242528740627e-20 7.640908233652337306e-21 1.849156542974073558e-26 5.220690565518543045e-21 5.439173775487768475e-24 3.861058868763272846e-23 1.378876510591971613e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.373749124558212270e-21 5.718469867719948399e-21 2.742587137453510993e-21 4.190653465901027142e-20 4.286500145806600131e+02 4.115852846800610583e-20 4.035629194574291063e-20 7.414942541953242493e-21 1.840062690414723753e-26 5.218144103535800016e-21 5.420534632333249277e-24 3.852387966357110452e-23 1.378840536966714598e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.379078850460693442e-21 5.484155848389082435e-21 2.744225391026903501e-21 4.185990936368536287e-20 4.291000233045903656e+02 4.218176137622972194e-20 4.038263299291029330e-20 7.372910245564064966e-21 1.831110057260258027e-26 5.215597542539915210e-21 5.405020157711310233e-24 3.844828829668007085e-23 1.378804565165507337e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.390924691152973070e-21 4.682218715660861634e-21 2.745863708299904931e-21 4.178061190638133568e-20 4.296000232774667893e+02 4.134679411739629288e-20 4.041191250027838935e-20 8.109260858359862060e-21 1.821213761500808025e-26 5.212768085329063949e-21 5.387814333160999141e-24 3.836441387029864968e-23 1.378764601054599012e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.419876184564133142e-21 5.069063083688415639e-21 2.747684025437113740e-21 4.199070663637735063e-20 4.301000232504062524e+02 4.157392328518515119e-20 4.044120487072438493e-20 7.729398510317406023e-21 1.811317465740109921e-26 5.209938628117856090e-21 5.370608519365667900e-24 3.828053944390664906e-23 1.378724640923029269e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.428949074839487141e-21 5.484384078910289490e-21 2.749504342574551628e-21 4.199953127629202336e-20 4.306000232234085843e+02 4.127585331851503742e-20 4.047051007631759535e-20 7.141354522997369974e-21 1.801551842837742812e-26 5.207109170906292385e-21 5.353402716429046541e-24 3.819666501750410425e-23 1.378684684771144364e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.414126121334859270e-21 5.460578419835777927e-21 2.751314013948651043e-21 4.191974204897078253e-20 4.311000231964735576e+02 4.117987647721604096e-20 4.049982808919589907e-20 7.824553666796141792e-21 1.791788880400710713e-26 5.204311498438287329e-21 5.336196924456198543e-24 3.811279059109105053e-23 1.378644732599289986e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.427148628722783286e-21 5.092143137257892334e-21 2.753122135157914528e-21 4.202372035292097114e-20 4.316000231696008882e+02 4.094508769837894871e-20 4.052915888156568947e-20 8.663031905605474966e-21 1.782091323120549521e-26 5.201520800913855836e-21 5.318991143553553166e-24 3.802891616466754078e-23 1.378604784407812576e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.473813259041022213e-21 4.871489421068322164e-21 2.754930256367403331e-21 4.219137188038176589e-20 4.320500144659180819e+02 4.413522945162505839e-20 4.055556698878131267e-20 8.351957687712552158e-21 1.773515018414269113e-26 5.199006841845229875e-21 5.303506248971901189e-24 3.795343063686218729e-23 1.378568876876912043e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.449692264736489417e-21 4.747533399376179763e-21 2.756557534068775189e-21 4.213881932800641913e-20 4.325000231213866755e+02 3.970042704639290166e-20 4.058198642369408922e-20 7.869188480759429878e-21 1.764938382862985422e-26 5.196479870164520923e-21 5.288020766170707273e-24 3.787794219707894624e-23 1.378533197747154100e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.457289524400305623e-21 5.503275495998485730e-21 2.758184874545049671e-21 4.216330497842713331e-20 4.330000230946876059e+02 4.000663966810203204e-20 4.061135285135868097e-20 8.487617825489907806e-21 1.755456624779255903e-26 5.193672178006754416e-21 5.270815016842644638e-24 3.779406777062631362e-23 1.378493558817074888e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.467422680854410455e-21 5.203239629220117068e-21 2.759992995755166659e-21 4.227342145399142643e-20 4.335000230680502114e+02 4.149570817390610254e-20 4.064073195352049172e-20 8.196019542427637605e-21 1.746059566456352657e-26 5.190864485848641091e-21 5.253609279001982997e-24 3.771019334416333665e-23 1.378470936961558488e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.451735016837108627e-21 4.526984271435834594e-21 2.761801116965506332e-21 4.216537919329384917e-20 4.340000230414740372e+02 4.119856478851397089e-20 4.067012370271229982e-20 8.537191416098923607e-21 1.736662508132299171e-26 5.188056793690183958e-21 5.236403552761996659e-24 3.762631891769008586e-23 1.378469875996044504e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.423569035128103300e-21 4.996390513573618180e-21 2.763609238176067562e-21 4.231297859884071992e-20 4.345000230149591403e+02 3.998517307032585255e-20 4.069952807153439346e-20 8.401298573431725982e-21 1.727350161781642075e-26 5.185249101531383015e-21 5.219197838237430770e-24 3.754244449120655537e-23 1.378468818332761412e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.431666454364313569e-21 4.954866459357579711e-21 2.765417359386849973e-21 4.230921563687147070e-20 4.350000229885051795e+02 4.034248452350916935e-20 4.072894503265445636e-20 7.597728363036546195e-21 1.718085456389465578e-26 5.182473718832894516e-21 5.201992135544567437e-24 3.745857006471280396e-23 1.378435458443320236e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.398617702299018323e-21 5.256152385170448176e-21 2.767225480597853189e-21 4.222052574696626005e-20 4.355000229621119274e+02 4.186685659349640143e-20 4.075837455880736311e-20 7.335686413568723622e-21 1.708820750996164095e-26 5.179704488209841480e-21 5.184786444801224987e-24 3.737469563820887276e-23 1.378395950475375287e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.387223551403777962e-21 4.547679102605149756e-21 2.769034422169540169e-21 4.211960892029860867e-20 4.360000229357792705e+02 4.101969322808900943e-20 4.078781662279508890e-20 7.713000696373415853e-21 1.699739146186311539e-26 5.176940331956021856e-21 5.167580766126787362e-24 3.729082121169477355e-23 1.378356516220432968e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.405761552418360662e-21 3.936589464651538162e-21 2.770843714077248868e-21 4.215434540870357848e-20 4.365000229095068676e+02 4.001811466664802722e-20 4.081727119748646879e-20 7.533320308807606263e-21 1.690673453232009541e-26 5.174192240497366579e-21 5.150375099642242318e-24 3.720694678517056508e-23 1.378317308305502072e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.476965465385123124e-21 4.198930537698107067e-21 2.772653005985175362e-21 4.217788552132196416e-20 4.370000228832946050e+02 4.142409591819114944e-20 4.084673825581713150e-20 7.727076622094745235e-21 1.681643072331124837e-26 5.171444149038381035e-21 5.133169445470190243e-24 3.712307235863627086e-23 1.378278103635687149e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.474222489497236603e-21 4.286119553867570122e-21 2.774462297893320027e-21 4.224985707282063718e-20 4.375000228571422554e+02 4.064972752726492466e-20 4.087621777078925263e-20 7.362945008030866512e-21 1.672773507577653588e-26 5.168672391712108048e-21 5.115963803734886031e-24 3.703919793209192618e-23 1.378238902211265614e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.462963731553247038e-21 4.490301248813729112e-21 2.776271589801680984e-21 4.223393191974334581e-20 4.380000228310496482e+02 3.955784766549144601e-20 4.090570971547144036e-20 9.460595982760181067e-21 1.663903942823122213e-26 5.165886132315524980e-21 5.098758174562256720e-24 3.695532350553755452e-23 1.378199704032513569e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.422220793106032630e-21 4.262786055741951600e-21 2.778080881710258231e-21 4.265300645501931834e-20 4.385000228050165560e+02 4.017137394403213946e-20 4.093521406299861501e-20 7.109492671993352317e-21 1.655062372221171226e-26 5.163099875609000361e-21 5.081552558079943364e-24 3.687144907897320292e-23 1.378160509112895407e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.428015052664263265e-21 3.772496164970296822e-21 2.779890173619051018e-21 4.217574767754545991e-20 4.390000227790426948e+02 4.181312778974142228e-20 4.096473078657175030e-20 7.216141371752949046e-21 1.646259452970433918e-26 5.160372603023403546e-21 5.064346954417315728e-24 3.678757465239891839e-23 1.378121606543889392e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.428430500791411429e-21 3.851014392738938421e-21 2.781699465528058214e-21 4.222937941429644490e-20 4.394500142223231478e+02 3.892744898157238360e-20 4.099130589316005593e-20 7.936290779869386813e-21 1.638336975881437793e-26 5.157918104241874028e-21 5.048862215834207638e-24 3.671208909994065068e-23 1.378086597671763192e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.426385378660033582e-21 3.740829407326251521e-21 2.783327797367545913e-21 4.237395165440133598e-20 4.399000227324386287e+02 4.114159715051789243e-20 4.101789199134943400e-20 8.640402208667134759e-21 1.630537165379325529e-26 5.155463512368516476e-21 5.033376900549911573e-24 3.663660068454022463e-23 1.378051590102119902e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.440678763240817367e-21 4.289429644221544240e-21 2.784956190964809751e-21 4.258912953426878450e-20 4.404000227066297271e+02 3.957781864031267708e-20 4.104744322584150379e-20 8.644765649040303447e-21 1.621990403230562392e-26 5.152736239782019891e-21 5.016171333485777455e-24 3.655272625793826896e-23 1.378012696625203084e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.428416660632217267e-21 4.286411038877423687e-21 2.786759041603415894e-21 4.261754637734213188e-20 4.409000226808794309e+02 3.996195823746843119e-20 4.107700673514358039e-20 9.197376614962206770e-21 1.613443641080797674e-26 5.150008967195202818e-21 4.998965779749278533e-24 3.646885183132648029e-23 1.377973806395983435e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.433349208963313479e-21 3.878880314948409789e-21 2.788552737532349891e-21 4.272249064461705305e-20 4.414000226551875130e+02 3.991256493013432978e-20 4.110658249277184605e-20 7.946248143464471422e-21 1.604944833238127450e-26 5.147281694608067516e-21 4.981760239478531719e-24 3.638497740470489386e-23 1.377934919414736303e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.435199190809609283e-21 3.918079887390453212e-21 2.790346433461493033e-21 4.250277315544407768e-20 4.419000226295536322e+02 4.095889090632561677e-20 4.113617047230769379e-20 7.725341487290799080e-21 1.596466572803223591e-26 5.144554422020616241e-21 4.964554712813571453e-24 3.630110297807357435e-23 1.377896035681736285e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.437743826063094089e-21 3.626715652937639428e-21 2.792140129390844565e-21 4.246466793187284932e-20 4.424000226039777317e+02 4.004741015934027488e-20 4.116577064739754085e-20 8.163573290650922338e-21 1.587988312367336804e-26 5.141827149432848993e-21 4.947349199896374676e-24 3.621722855143253349e-23 1.377857155197258540e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.497522640929251162e-21 3.731333501599419825e-21 2.793933825320403738e-21 4.258608111561127703e-20 4.429000225784595841e+02 4.103249191816868542e-20 4.119538299175275044e-20 7.395612745428173266e-21 1.579675596323134007e-26 5.139151007287922642e-21 4.930143700870901243e-24 3.613335412478180069e-23 1.377818528573425334e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.647550731501700000e-21 3.311781550225797113e-21 2.795727521250170549e-21 4.244483086830633486e-20 4.434000225529990189e+02 3.965043253433550061e-20 4.122500747914937292e-20 7.588967805338662545e-21 1.571373438472508182e-26 5.136481834491509395e-21 4.912938215883131389e-24 3.604947969812141120e-23 1.377779939358765090e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.870002928283805081e-21 3.240522812514141871e-21 2.797521217180143871e-21 4.251118376282566415e-20 4.439000225275957519e+02 4.039901613378990787e-20 4.125464408342808566e-20 7.787429662504243938e-21 1.563099062337088932e-26 5.133804389324293795e-21 4.895732745081092178e-24 3.596560527145140616e-23 1.377741353393859977e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.712587944667869818e-21 3.215648216096848888e-21 2.799314913110322576e-21 4.256706086092099066e-20 4.444500328120886934e+02 4.040111515694647059e-20 4.128725892363720727e-20 7.741153046475446900e-21 1.554157466569189760e-26 5.130826890039820846e-21 4.876806388904676352e-24 3.587334167221490943e-23 1.377698911790539181e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.505914951037283451e-21 2.916362927163520918e-21 2.801288015628271937e-21 4.256064046243712595e-20 4.450000224719095741e+02 4.134723851229508914e-20 4.131988713576553037e-20 8.047920667600371541e-21 1.545216206099530528e-26 5.127849502407708116e-21 4.857880759993303641e-24 3.578108153274367956e-23 1.377656475711552829e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.394926862429985921e-21 2.846957440849359267e-21 2.803261044157436596e-21 4.264042028236906137e-20 4.455000224466885470e+02 4.040349566964394767e-20 4.134956233902569302e-20 7.514646634058933266e-21 1.537159640852986509e-26 5.125158088346150929e-21 4.840675335604921985e-24 3.569720710604310579e-23 1.377618113357239121e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.406408683843861000e-21 3.190828877629161930e-21 2.805050105702363835e-21 4.259636457365004362e-20 4.460000224215241360e+02 3.997961501060496517e-20 4.137924955000051908e-20 8.333682660056891294e-21 1.529159641255616937e-26 5.122471521317183659e-21 4.823469926047226519e-24 3.561333267933303404e-23 1.377579867481152619e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.403377537357984207e-21 3.470333055187406357e-21 2.806832452383498856e-21 4.279862475355191725e-20 4.465000223964160568e+02 4.065914335301709396e-20 4.140894874286402827e-20 8.360582166965642603e-21 1.521159641657345943e-26 5.119787941033914336e-21 4.806264531479525382e-24 3.552945825261351130e-23 1.377541683899319820e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.407484659705889432e-21 3.319015566964316381e-21 2.808614799064834745e-21 4.282051727554397190e-20 4.470000223713641390e+02 4.061300772865837030e-20 4.143865989185387425e-20 7.947725717175181772e-21 1.513246504314488351e-26 5.117138687435309110e-21 4.789059152063402025e-24 3.544558382588457286e-23 1.377503502902672002e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.417675724214116910e-21 3.399829653722621708e-21 2.810397145746370750e-21 4.277709386494188909e-20 4.475000223463681550e+02 3.971300254505868268e-20 4.146838297127117608e-20 9.139591322487505764e-21 1.505360790422996408e-26 5.114489433836407472e-21 4.771853787962778402e-24 3.536170939914624809e-23 1.377465324491424139e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.455934652619626990e-21 3.366344124989352231e-21 2.812179492428106496e-21 4.304156100657354841e-20 4.480000223214280481e+02 4.161416194052624340e-20 4.149811795548038583e-20 7.532530588372435820e-21 1.497475076530623417e-26 5.111840180237209421e-21 4.754648439343939944e-24 3.527783497239854876e-23 1.377427148665791016e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.451747495228139246e-21 3.364568928157646832e-21 2.813961839110040853e-21 4.275755570325130554e-20 4.485000222965435341e+02 4.187777019152376899e-20 4.152786481890912005e-20 8.042603642111930348e-21 1.489751996331359721e-26 5.109190926637716462e-21 4.737443106375598008e-24 3.519396054564152188e-23 1.377388975425987985e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.438398171798475545e-21 3.740751921248505182e-21 2.815744185792173821e-21 4.290967201798904433e-20 4.490000222717143856e+02 4.085198540007693731e-20 4.155762354108787909e-20 7.874550473032277914e-21 1.482035684657801020e-26 5.106541673037930852e-21 4.720671545640352108e-24 3.511171236072063037e-23 1.377350804772229832e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.447016721888554647e-21 3.197120677859700233e-21 2.817526532474503896e-21 4.286343000196927798e-20 4.495000222469405458e+02 4.065753898847339601e-20 4.158739411999653697e-20 7.787023522656369899e-21 1.474333278110440865e-26 5.103879881349650379e-21 4.706361945412887665e-24 3.503869453507913629e-23 1.377312835701846840e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.423677734702785881e-21 3.612962580509098684e-21 2.819308879157031454e-21 4.290834155314880923e-20 4.500000222222216735e+02 4.057235620293582036e-20 4.161717650154297990e-20 7.212924972018944500e-21 1.466716257210413243e-26 5.101213214814817963e-21 4.692052350209982724e-24 3.496567670942961945e-23 1.377274946588906129e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.403244560833660873e-21 3.925297961257511977e-21 2.821091225839754615e-21 4.286340850719700219e-20 4.505000221975577688e+02 4.232334294446495187e-20 4.164697066040646524e-20 7.640086959216919348e-21 1.459099236309548196e-26 5.098547290664696167e-21 4.677742760077765152e-24 3.489265888377207399e-23 1.377237060062994702e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.479640460811020585e-21 3.635104231019671677e-21 2.822874298990557414e-21 4.294305808484754346e-20 4.510000221729484906e+02 4.200723695631491792e-20 4.167677657132866852e-20 8.304842901321301907e-21 1.451539951906571804e-26 5.095917661164492959e-21 4.663433175062935137e-24 3.481964105810655280e-23 1.377199176124325840e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.547070126942274565e-21 4.010266529335744352e-21 2.824665152916336212e-21 4.313055536817806375e-20 4.515500322961639199e+02 4.123865266343980586e-20 4.170957722235522040e-20 8.345572463672703271e-21 1.443359519651424055e-26 5.093025015331286206e-21 4.647692347022846759e-24 3.473931996757082630e-23 1.377157506011333454e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.978349904083578046e-21 4.098053706757517996e-21 2.826635128590052544e-21 4.319573920556772103e-20 4.521000221189997319e+02 4.247964430595849804e-20 4.174239081852976387e-20 8.322964752982325546e-21 1.435179389328683356e-26 5.090142531584633328e-21 4.631952106277330999e-24 3.465900184161440825e-23 1.377115982177754657e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.722058727278756848e-21 4.524684395613836284e-21 2.828605031553735830e-21 4.325442656206084647e-20 4.526000220945642241e+02 4.678410347186052953e-20 4.177223416702806230e-20 7.339257649545452265e-21 1.427809816584004462e-26 5.087532237594554419e-21 4.617642537958698178e-24 3.458598401592350813e-23 1.377078378824372656e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.262024981136060345e-21 4.103163792313529035e-21 2.830395885480137170e-21 4.315150863813681861e-20 4.531000220701826606e+02 5.449106248184644661e-20 4.180208916217816846e-20 7.369859133597346921e-21 1.420471788772815519e-26 5.084921943604193390e-21 4.603332974959961937e-24 3.451296619022473221e-23 1.377040778059459119e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.391381815783440112e-21 4.278026571327736021e-21 2.832186739406731479e-21 4.314539218555298697e-20 4.536000220458548711e+02 4.347310185697820208e-20 4.183195577904382153e-20 7.404064697907100651e-21 1.413133760960837652e-26 5.082311649613551748e-21 4.589023417330907401e-24 3.443994836451809810e-23 1.377003179883226201e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.746205807174721252e-21 4.485758819294462498e-21 2.833977593333518757e-21 4.317015903244580170e-20 4.541000220215806280e+02 4.086321811601631478e-20 4.186183399275024600e-20 7.077793124247568854e-21 1.405932830851168452e-26 5.079701355622630244e-21 4.574713865121944909e-24 3.436693053880364696e-23 1.376965584295886242e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.465458007231113876e-21 4.393643607491316336e-21 2.835768447260497499e-21 4.312426413111394075e-20 4.546000219973598178e+02 4.307058007611227451e-20 4.189172377848396510e-20 7.131553059517846526e-21 1.398758006023903176e-26 5.077091061631430383e-21 4.560404318384112224e-24 3.429391271308139641e-23 1.376927991297650644e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.403137112751006390e-21 4.354230037905638400e-21 2.837559301187667706e-21 4.315587337956099997e-20 4.551000219731921561e+02 4.320616727117486380e-20 4.192162511149271050e-20 7.483125747277078544e-21 1.391583181195875953e-26 5.074480767639952165e-21 4.546094777169095095e-24 3.422089488735138172e-23 1.376890400888731936e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.384969045730282007e-21 4.624508673847759080e-21 2.839350155115028250e-21 4.327162264056663999e-20 4.556500320055586712e+02 4.349875202516776596e-20 4.195453048735687445e-20 7.690142331840306462e-21 1.383796470075173493e-26 5.071609391735685861e-21 4.530354000397882792e-24 3.414057381008283695e-23 1.376849053673683026e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.413877711962956130e-21 4.368530351711416660e-21 2.841320130463350066e-21 4.331391515947880444e-20 4.562000219202099061e+02 4.473001022665203269e-20 4.198744856893139476e-20 8.463350761428017960e-21 1.376011997437033099e-26 5.068769231064620765e-21 4.514613806195253292e-24 3.406025567071809556e-23 1.376807861381400492e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.416386453475955824e-21 4.371625422863305565e-21 2.843279077684943824e-21 4.348982456465572288e-20 4.567000218962114104e+02 4.302816584499543710e-20 4.201738668759459452e-20 7.181889413634578921e-21 1.368970883795436564e-26 5.066214486661693304e-21 4.500304283008222173e-24 3.398723784496337786e-23 1.376770547590465617e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.441154226696140396e-21 4.302921552588319187e-21 2.845059425122286262e-21 4.328151965770949642e-20 4.572000218722654949e+02 4.273483493621108524e-20 4.204733625023780692e-20 7.924072540849255650e-21 1.362005849163970318e-26 5.063659742258497267e-21 4.485994765568321056e-24 3.391422001920097830e-23 1.376733236390054537e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.434008966857358320e-21 4.223667147908244751e-21 2.846839772559816027e-21 4.343163442291095348e-20 4.577000218483717617e+02 4.300062898672498977e-20 4.207729723242439346e-20 8.147156444256491594e-21 1.355040814531776849e-26 5.061075069252964270e-21 4.471685253930748216e-24 3.384120219343095566e-23 1.376695927780377710e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.417907454560767382e-21 4.292336816704081455e-21 2.848620119997531990e-21 4.350787620369519630e-20 4.582000218245302676e+02 4.249445651913906505e-20 4.210726960977802135e-20 8.504076317970237689e-21 1.348142757893216742e-26 5.058483828500609296e-21 4.457375748151399145e-24 3.376818436765330994e-23 1.376658621761645974e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.396632697367474815e-21 4.285791403799501905e-21 2.850400467435433399e-21 4.360354858779410119e-20 4.587500317892813655e+02 4.293958211038835698e-20 4.214025295653164645e-20 8.265595850842786845e-21 1.340641233096194974e-26 5.055636792968190106e-21 4.441635012697980142e-24 3.368786330025902939e-23 1.376617635004928720e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.414811163725299256e-21 4.495547778485287764e-21 2.852358885191946876e-21 4.361105685228664571e-20 4.593000217722616298e+02 4.254581097719197348e-20 4.217324883120195462e-20 7.369740927842910325e-21 1.333139980828325335e-26 5.052807134360103119e-21 4.425894856337899219e-24 3.360754515091581034e-23 1.376576969291326607e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.483116773923741429e-21 4.517768819423614038e-21 2.854317231799467629e-21 4.348654928593248986e-20 4.598000217485858911e+02 4.208794270090820478e-20 4.220325750997995291e-20 7.954001427520555664e-21 1.326396374269016559e-26 5.050234670713797030e-21 4.411585369688988228e-24 3.353452732511396119e-23 1.376540013768162770e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.445562940386675126e-21 4.395182822063522849e-21 2.856097579237959230e-21 4.360443254377194543e-20 4.603000217249614821e+02 4.271142310463407149e-20 4.223327748219876917e-20 6.584796376021393384e-21 1.319674152364411475e-26 5.047681049221209807e-21 4.397275889141089813e-24 3.346150949930461238e-23 1.376503060354723532e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.414627977813119484e-21 4.567985913892888141e-21 2.857877926676634021e-21 4.342141623357813885e-20 4.608000217013884594e+02 4.238019208104651041e-20 4.226330872379296386e-20 7.287878725941570549e-21 1.312951930459115617e-26 5.045144817456725136e-21 4.382966414753972719e-24 3.338849167348775805e-23 1.376466109051179292e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.519455278983839363e-21 4.431196493597162416e-21 2.859658274115491624e-21 4.355194154043541175e-20 4.613500316101286103e+02 4.097986956253633366e-20 4.229635667408032757e-20 8.340543676564065204e-21 1.305700273709485016e-26 5.042354912122535903e-21 4.367225715798197899e-24 3.330817061427307266e-23 1.376425464320285441e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.410588037714665014e-21 4.515030088446108312e-21 2.861608616411206397e-21 4.377706630797254446e-20 4.619000216497072415e+02 4.256280760184907234e-20 4.232941700528671208e-20 8.284985950066977803e-21 1.298463163395581262e-26 5.039565107573948858e-21 4.351485593087888792e-24 3.322785245666447674e-23 1.376384823611049852e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.349663051632885634e-21 4.449497357941907398e-21 2.863555563045854136e-21 4.378964350661132573e-20 4.624000216262970753e+02 4.097807911226195869e-20 4.235948414785227912e-20 8.497656137235647685e-21 1.291912050291521992e-26 5.037028875808638143e-21 4.337176138826174645e-24 3.315483463082383628e-23 1.376347879060311774e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.373761304072832289e-21 4.761569310857154094e-21 2.865325546503175324e-21 4.389274451937589241e-20 4.629000216029374997e+02 4.227087809602043540e-20 4.238956245936442798e-20 7.435735622523631157e-21 1.285473694427933023e-26 5.034496294085926129e-21 4.322866690985001091e-24 3.308181680497581371e-23 1.376310988759174011e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.345240926768061745e-21 4.861122214108445718e-21 2.867095529960675564e-21 4.373862236994651098e-20 4.634500314668957799e+02 4.432833460957597913e-20 4.242266206908424553e-20 6.974917250477053591e-21 1.278391375631757754e-26 5.031726460238654568e-21 4.307126022822721671e-24 3.300149575230087947e-23 1.376270640490214456e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.368165730312000953e-21 4.782103454885430014e-21 2.869042546772974763e-21 4.368657715396690856e-20 4.640000215517236484e+02 4.441483301236561496e-20 4.245577394238764971e-20 7.941721838795804531e-21 1.271334345422127565e-26 5.028956725998513928e-21 4.291385928651330368e-24 3.292117758808427733e-23 1.376230296226784628e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.402886429822150957e-21 4.542109443814343679e-21 2.870989493567803073e-21 4.385875777788260986e-20 4.645000215285248260e+02 4.253295981130367686e-20 4.248588783515989690e-20 6.924333568443654900e-21 1.264948138821880837e-26 5.026427747962481092e-21 4.277076501790125787e-24 3.284815976221278014e-23 1.376193780479904922e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.388763093117355164e-21 4.724275695868017750e-21 2.872759477025872441e-21 4.373393686627287350e-20 4.650000215053758552e+02 4.258578149743783582e-20 4.251601279748574262e-20 7.216669693397633721e-21 1.258561932220997430e-26 5.023892033794165160e-21 4.262767081624024954e-24 3.277514193633399488e-23 1.376157364461701501e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.428544223055160461e-21 5.327191316201246557e-21 2.874529460484118226e-21 4.388061854436025927e-20 4.655500313249551141e+02 4.252975011963102994e-20 4.254916360682438238e-20 7.255546604074951268e-21 1.251651583251583856e-26 5.021102698280584884e-21 4.247026445503073001e-24 3.269482089013998417e-23 1.376117308564097901e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.411674767070601058e-21 4.995845280054122499e-21 2.876476477139317213e-21 4.387944793340366927e-20 4.661000214546230040e+02 4.223486669083727111e-20 4.258232656364230124e-20 7.088914042856926773e-21 1.244812250210543992e-26 5.018331546631394800e-21 4.231286381160185132e-24 3.261450271937513794e-23 1.376076994590757979e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.359272366282139991e-21 4.795063712787975384e-21 2.878423424092877885e-21 4.386013152830457395e-20 4.666000214316326264e+02 4.430231700268287547e-20 4.261248679081422351e-20 7.473345099716792233e-21 1.238594563421608233e-26 5.015813561135663051e-21 4.216976982877675615e-24 3.254148489347320132e-23 1.376040328415264158e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.317694155597009482e-21 5.158542718069944757e-21 2.880194525580558210e-21 4.399284337526495065e-20 4.671500312176664238e+02 4.290482907745222943e-20 4.264567630369060633e-20 7.541380232807083597e-21 1.231817972144328523e-26 5.013067932339079578e-21 4.201236372051529790e-24 3.246116385217801630e-23 1.376000170838453959e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.302631194257128627e-21 5.311751254653056812e-21 2.882143615870152681e-21 4.405416804797343456e-20 4.677000213812268044e+02 4.381027485604837857e-20 4.267887787640420808e-20 8.602339658812158149e-21 1.225052339721352933e-26 5.010376491113145689e-21 4.185496331346147951e-24 3.238084567646366294e-23 1.375960404958350533e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.285894584578308125e-21 5.384914243041771277e-21 2.884092636622853336e-21 4.428830417475012559e-20 4.682000213583933714e+02 4.247282996472845849e-20 4.270907312953677189e-20 8.121147238107159056e-21 1.218914843996559634e-26 5.007929682714245348e-21 4.171186955670826605e-24 3.230782785053880418e-23 1.375924255732169154e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.262429826650367487e-21 5.460816009798476923e-21 2.885864505278719429e-21 4.423498618751071460e-20 4.687000213356086533e+02 4.403218770976454867e-20 4.273927927958931477e-20 7.134572838361876762e-21 1.212874027945305838e-26 5.005449893321957102e-21 4.156877587213694441e-24 3.223481002460682781e-23 1.375887951579546711e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.261328912382740378e-21 5.301859008171807808e-21 2.887636373934758179e-21 4.407420877308014713e-20 4.692500310779602728e+02 4.376198733499423288e-20 4.277251919344418770e-20 6.799808091934462075e-21 1.206229012282609112e-26 5.002699844610198331e-21 4.141137010807931182e-24 3.215448898969080377e-23 1.375847912885506624e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.314168020930141041e-21 5.569802918466372114e-21 2.889585464069554902e-21 4.408793767922946425e-20 4.698000212856530311e+02 4.373351987888873351e-20 4.280577105316973620e-20 6.778506094133287474e-21 1.199640830255554818e-26 4.999950248936474352e-21 4.125397002386269624e-24 3.207417080753154990e-23 1.375807883246979051e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.379124596788256753e-21 5.414964174245569263e-21 2.891534484978648968e-21 4.409943728959767183e-20 4.703000212630231545e+02 4.461238068896516302e-20 4.283601192573693748e-20 7.596151601311650102e-21 1.193748938630328598e-26 4.997467979545275119e-21 4.111789039136084913e-24 3.200389951848813686e-23 1.375771742897598558e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.431688111049331139e-21 5.599910575233399521e-21 2.893306353635236533e-21 4.428627172225694387e-20 4.708500309723539772e+02 4.520202717056025546e-20 4.286928996745389029e-20 8.009429523927986210e-21 1.187267743136592500e-26 4.994737434889022411e-21 4.098703504868923452e-24 3.193397514229625405e-23 1.375731990251477418e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.466076066538616556e-21 5.426907208531249292e-21 2.895255443653016085e-21 4.437061263618142338e-20 4.714000212134064327e+02 4.495781621843701873e-20 4.290257986880219151e-20 7.488842309371384254e-21 1.180828671811407806e-26 4.992028065934856370e-21 4.085618486373844417e-24 3.186405324116471486e-23 1.375678256552408679e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.428423244956009350e-21 5.605770183925382194e-21 2.897204464680328019e-21 4.433268355798464581e-20 4.719000211909298628e+02 4.548652880982108832e-20 4.293285523926459919e-20 6.965286654650589078e-21 1.175004347748905584e-26 4.989598488579284660e-21 4.073722850543573826e-24 3.180048675146252684e-23 1.375607164108830218e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.368602694397720514e-21 5.912252076691808240e-21 2.898970949725825017e-21 4.431440537467934974e-20 4.724500308674629423e+02 4.601419006719039486e-20 4.296617112360701543e-20 7.524782314728889622e-21 1.168597478273615201e-26 4.986925906348243665e-21 4.060637471474127215e-24 3.173056237944031645e-23 1.375528990406726057e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.361795850060655562e-21 5.997449405114322592e-21 2.900904581490895359e-21 4.444902561270112752e-20 4.730000211416485740e+02 4.512068181748256712e-20 4.299949878224221036e-20 6.886940867147563197e-21 1.162305262709833771e-26 4.984213370218765827e-21 4.047552608095736940e-24 3.166064047409645791e-23 1.375477444905473249e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.361071781566698537e-21 6.675739165517600587e-21 2.902838145044447220e-21 4.447433719606002340e-20 4.735000211193237192e+02 4.578082230004281087e-20 4.302980840014475649e-20 7.465839722960106552e-21 1.156613987796162625e-26 4.981731100826052181e-21 4.035657115307988476e-24 3.159707398437498003e-23 1.375441389993131668e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.377425507885019270e-21 6.312992344255493282e-21 2.904595961098633065e-21 4.454437701020993275e-20 4.740500307632799490e+02 4.610095025506828901e-20 4.306316187179321687e-20 7.161313536733366298e-21 1.150353475338781862e-26 4.979003348065292772e-21 4.022571895828312094e-24 3.152714961649435950e-23 1.375401750698832584e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.389698318178432949e-21 6.727804981923385596e-21 2.906529592749175274e-21 4.458751026901798849e-20 4.746000210703746234e+02 4.698735389267739287e-20 4.309652703307880893e-20 6.698443479059958701e-21 1.144180166243859073e-26 4.976349548681409054e-21 4.009487192026166516e-24 3.145722770696667558e-23 1.375362640466523414e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.384612561197387829e-21 7.748348288679024127e-21 2.908463156418423239e-21 4.471296994487554723e-20 4.751500306920611365e+02 4.638869805168362451e-20 4.312990619893879381e-20 7.898730269180256948e-21 1.138008246193793514e-26 4.973695656101243438e-21 3.996402084899458483e-24 3.138730334191727434e-23 1.375323530893046102e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.412081499947684721e-21 7.834025192992664345e-21 2.910396787990673763e-21 4.495603682903250101e-20 4.757000210216518212e+02 4.832118537399029021e-20 4.316329699662843097e-20 6.840589229235988920e-21 1.131860707089391306e-26 4.971016797780589936e-21 3.983317493481505322e-24 3.131738142952960679e-23 1.375284306530461517e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.418890548468919011e-21 9.156453195918107749e-21 2.912330351739009364e-21 4.506442980656094724e-20 4.762000209995795785e+02 4.631126498811340564e-20 4.319366388448057898e-20 7.721078328748835194e-21 1.126330505991237745e-26 4.968552009157002191e-21 3.971422251456156103e-24 3.125381493977601441e-23 1.375248510393132455e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.410955255572461686e-21 9.961960526829986798e-21 2.914088167794082942e-21 4.540495372260043554e-20 4.767500305890569052e+02 4.593776338845606720e-20 4.322708021133874675e-20 6.783447327981784283e-21 1.120247178451247292e-26 4.965840694279296921e-21 3.958337311717242845e-24 3.118389057882145949e-23 1.375209135893993694e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.427449175753685119e-21 1.037077187400490052e-20 2.916021799253097437e-21 4.537886167442662324e-20 4.773000209511833418e+02 4.846843501242313515e-20 4.326050808651081753e-20 7.352833660527049123e-21 1.114224839835199919e-26 4.963173325480303683e-21 3.945252887793534290e-24 3.111396866229742715e-23 1.375169971634773432e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.438998744921615606e-21 9.945097437494655809e-21 2.917952989511862773e-21 4.540430616554373683e-20 4.778000209292586646e+02 4.812330263991429093e-20 4.329090860540832853e-20 7.594046732032524022e-21 1.108811506739238237e-26 4.960760738173506611e-21 3.933357800191044902e-24 3.105040217252507388e-23 1.375134427088198974e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.440917216950597670e-21 1.104668174313139873e-20 2.919701228873491083e-21 4.572639839599224818e-20 4.783500304867416730e+02 4.910402776023990466e-20 4.332436184330374467e-20 8.213926209688960801e-21 1.102856736596889407e-26 4.958108187251029259e-21 3.920273032703701804e-24 3.098047781563805267e-23 1.375095348785173106e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.504469266960503410e-21 1.414654309239427490e-20 2.921624325673145104e-21 4.671046574400318285e-20 4.789000208811856396e+02 4.808439546238081358e-20 4.335782654666545579e-20 8.121982646406252451e-21 1.096959777267366335e-26 4.955472816610985333e-21 3.907188781212971575e-24 3.091055589500539134e-23 1.375056521509768954e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.603512911004855126e-21 1.364618929403365554e-20 2.923547355469637679e-21 4.657953469073634420e-20 4.794500304167960962e+02 4.787976040163367163e-20 4.339130501692353835e-20 7.276709745558948311e-21 1.091093008887522396e-26 4.952837354252851366e-21 3.894104135069108228e-24 3.084063154089909607e-23 1.375017694916977381e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.704922109512521645e-21 1.753104235342377256e-20 2.925470452192814602e-21 4.775961344466932426e-20 4.800000208333328828e+02 4.824648854374036663e-20 4.342479489607490941e-20 7.594567943185205841e-21 1.085226444444464009e-26 4.950201983506946744e-21 3.881020005091665255e-24 3.077070961745770853e-23 1.374978871707860403e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.855479010137723644e-21 1.833494764444633034e-20 2.927393482066554271e-21 4.814529096977698014e-20 4.805500303471707184e+02 4.660313767739677008e-20 4.345829848211283551e-20 8.167106588536273194e-21 1.079476769356697470e-26 4.947566521253140252e-21 3.867935482745338440e-24 3.070078526611943209e-23 1.374940049184938345e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.651535848898821378e-21 2.321442426509729500e-20 2.929316578713603546e-21 5.031811929462110183e-20 4.811000207856990301e+02 4.465548276560372231e-20 4.349181342078250263e-20 8.517995474115389924e-21 1.073736471799608146e-26 4.944931150401859426e-21 3.854851476773186666e-24 3.063086333988219590e-23 1.374901230042804809e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.483519178709742529e-21 2.883808595717802993e-20 2.931239608664236344e-21 5.322467405799842224e-20 4.816500302778633795e+02 4.499486496808644200e-20 4.352534200664784237e-20 7.081398958528965947e-21 1.068016005839784601e-26 4.942295688251904946e-21 3.841767080745492341e-24 3.056093899129933698e-23 1.374862411590434431e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.466737318308597313e-21 3.929509113327380623e-20 2.933162705235504790e-21 5.937826234444144955e-20 4.822000207382824897e+02 4.381661183442720214e-20 4.355888188919310731e-20 6.795176469956382561e-21 1.062385840337074385e-26 4.939660317295730151e-21 3.828683201338776178e-24 3.049101706227905914e-23 1.374823596515981359e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.453672869038830010e-21 3.914276645209934606e-20 2.935085735262677881e-21 5.926825458569277742e-20 4.827000207168009069e+02 4.384018952887819923e-20 4.358938400461989112e-20 7.611184253619869530e-21 1.057267419504347446e-26 4.937271626983278464e-21 3.816788615691690168e-24 3.042745057245037030e-23 1.374788344772494094e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.452365753014815052e-21 3.960834324151963312e-20 2.936833974625855587e-21 5.969746537808047283e-20 4.832500301776158835e+02 4.324683355001602257e-20 4.362294874816904763e-20 6.366474613573747385e-21 1.051653468661560820e-26 4.934692272270490893e-21 3.803704408043732736e-24 3.035752622785304849e-23 1.374749795638916568e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.480592767872772823e-21 3.782795740782178440e-20 2.938759392675545181e-21 5.840820610771443158e-20 4.838000206696978012e+02 4.362689518496388085e-20 4.365652470756296763e-20 6.617749896449559854e-21 1.046073432675671811e-26 4.932113006514520644e-21 3.790620717447835898e-24 3.028760429480738428e-23 1.374711249870257073e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.520417540153191620e-21 3.310820528646065128e-20 2.940684774576707093e-21 5.552491169197575580e-20 4.843500301090799667e+02 4.351638972133292075e-20 4.369011416897988512e-20 7.048069965527776904e-21 1.040493204456246701e-26 4.929523830306402401e-21 3.777536642605553673e-24 3.021767995293487602e-23 1.374672832354082321e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.504969293204002947e-21 2.738638783262385133e-20 2.942610222807723086e-21 5.239876287013714551e-20 4.849000206228084267e+02 4.343008770726971846e-20 4.372371479104257824e-20 6.822684502615973446e-21 1.035005809809209388e-26 4.926924560070288550e-21 3.764453085162977149e-24 3.014775801713722084e-23 1.374634550435326764e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.518910761461618805e-21 2.617276278061507654e-20 2.944535604784664324e-21 5.177323902535508884e-20 4.854500300408546423e+02 4.661009636096512362e-20 4.375732885652581371e-20 9.258984243718106690e-21 1.029584801950298813e-26 4.924325200491850901e-21 3.751369145897347537e-24 3.007783367797721869e-23 1.374596269236990317e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.038935708088354322e-21 2.287554393596779946e-20 2.946461052940988465e-21 5.062313139406461315e-20 4.860000205761312486e+02 4.532228201844945152e-20 4.379095402775955610e-20 7.948181643445821398e-21 1.024163980203915466e-26 4.921742662125729651e-21 3.738285724422316639e-24 3.000791173944008568e-23 1.374557774105074641e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.583537311176464260e-21 2.025093468470686244e-20 2.948386434993364466e-21 4.927713515460245964e-20 4.865500299729378071e+02 4.341330208379914997e-20 4.382459258412259189e-20 7.738882659476683804e-21 1.018800492812248600e-26 4.919163307713119327e-21 3.725201923582361051e-24 2.993798740298034686e-23 1.374519286867937388e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.696807971623994415e-21 1.929213499193369684e-20 2.950311883075333794e-21 4.889114000620871378e-20 4.871000205296649597e+02 4.366472228040742280e-20 4.385824219164286977e-20 7.832170306189311945e-21 1.013451565044866890e-26 4.916580039962542533e-21 3.712118640968477081e-24 2.986806546171613749e-23 1.374480864332637797e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.548786540962472627e-21 1.820998711732243050e-20 2.952237265202803007e-21 4.851462911427397791e-20 4.876500299053273579e+02 4.300352664051567568e-20 4.389190512631063490e-20 7.305165088538898827e-21 1.008104027572598602e-26 4.913980680584412131e-21 3.699034981484030700e-24 2.979814112794451916e-23 1.374442649958089318e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.496602033090646205e-21 1.743233306001722984e-20 2.954162713210751550e-21 4.817421617239001129e-20 4.882000204834080250e+02 4.370795838164869955e-20 4.392557905784272003e-20 7.723108629269722422e-21 1.002841372629400667e-26 4.911381410044167610e-21 3.685951840707096545e-24 2.972821918396557612e-23 1.374404438544328048e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.519547054831879235e-21 1.804749240222944954e-20 2.956088095412973929e-21 4.849612269886621484e-20 4.887500298380212485e+02 4.302948088317065384e-20 4.395926625884821373e-20 7.730520555055697357e-21 9.975785380205597622e-27 4.908812106871738328e-21 3.672868325591677994e-24 2.965829485286999418e-23 1.374366367267991164e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.537329825343547755e-21 1.663132707440162468e-20 2.958001541268404551e-21 4.801956316701323362e-20 4.893000204373590805e+02 4.373846020883211110e-20 4.399296440272369071e-20 7.543718151486290267e-21 9.923408473276861563e-27 4.906267932670719460e-21 3.659785329712636128e-24 2.958837290618856611e-23 1.374328415409133075e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.539418578994576226e-21 1.613722207355397917e-20 2.959912183217290684e-21 4.785175606934169417e-20 4.898500297710174891e+02 4.418845492656230456e-20 4.402667575870456999e-20 6.788891040339817446e-21 9.871836169523532138e-27 4.903723671807537768e-21 3.646701962066458943e-24 2.951844857775703641e-23 1.374290463912931544e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.519566466982320749e-21 1.495495000617730622e-20 2.961822890248341257e-21 4.738254205352153349e-20 4.904500297345966260e+02 4.381902129988645826e-20 4.406346488365364814e-20 7.571972992111101459e-21 9.815576432679008272e-27 4.900948161771933637e-21 3.632429525632375655e-24 2.944216879131568726e-23 1.374249064873943500e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.492511964797239256e-21 1.348571115017577196e-20 2.963907262419655587e-21 4.709255980948717102e-20 4.910000203665983918e+02 4.274890212450539621e-20 4.409720022836052862e-20 7.625231029757655029e-21 9.764382532336425320e-27 4.898403987419816537e-21 3.619346759913207216e-24 2.937224684048159618e-23 1.374211118129823267e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.509413836337636247e-21 1.330919799283458910e-20 2.965817904482014352e-21 4.708290631504661884e-20 4.915500296680559131e+02 4.301199830604587876e-20 4.413094869711113320e-20 8.002604778060361635e-21 9.713524529396704652e-27 4.895853915736766099e-21 3.606263626481829996e-24 2.930232251614386073e-23 1.374173245305500888e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.497598847411684738e-21 1.189073542597751639e-20 2.967728611401200745e-21 4.679616148610769972e-20 4.921000203210725772e+02 4.413104718984986513e-20 4.416470797262744356e-20 8.751142033841253631e-21 9.662668250832451156e-27 4.893289770124728820e-21 3.593181013857581583e-24 2.923240056263808258e-23 1.374135554655812972e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.477875718758671751e-21 1.063397153548576063e-20 2.969639253536564292e-21 4.665856344229803928e-20 4.926500296018124345e+02 4.345658386689321386e-20 4.419848032522016754e-20 7.431706033871973913e-21 9.612329768772049416e-27 4.890725537667226077e-21 3.581157259589544925e-24 2.916678385229540485e-23 1.374097864385876123e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.524759078388022250e-21 1.006919857212988221e-20 2.971549960383778457e-21 4.633667965752066231e-20 4.932000202757498073e+02 4.197070573785515168e-20 4.423226344212120685e-20 8.723661859540958086e-21 9.562187761876418435e-27 4.888173375595171036e-21 3.570300398463375081e-24 2.910591250687967080e-23 1.374037576353546365e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.558727135694838476e-21 9.616628935775764567e-21 2.973460602591819529e-21 4.649870034627125953e-20 4.937500295358640869e+02 4.272452688422727411e-20 4.426605957002336775e-20 8.537157665384239398e-21 9.512044060501348691e-27 4.885629115072193584e-21 3.559443370490508143e-24 2.904503910440069738e-23 1.373962223232254443e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.584555845803878412e-21 9.698306550547714915e-21 2.975371309367381577e-21 4.651393224390833889e-20 4.943500295000159781e+02 4.416190066234415654e-20 4.430294095516220784e-20 7.505136211248439331e-21 9.458715331544126580e-27 4.882854900905968869e-21 3.547599770399492780e-24 2.897863287826261430e-23 1.373880714469277311e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.601046038824319263e-21 9.081033610983019190e-21 2.977448844657569179e-21 4.624610298023371657e-20 4.949000202061018854e+02 4.567375160050065256e-20 4.433676067218318013e-20 7.339644783675969981e-21 9.409921284303771543e-27 4.880381788334978506e-21 3.536743532901201219e-24 2.891776152928877052e-23 1.373843281602766049e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.516882591783693042e-21 9.364514467416550275e-21 2.979349792062737181e-21 4.630547205408942653e-20 4.954500294345199336e+02 4.465497778552885740e-20 4.437059331378859879e-20 8.112995479643197758e-21 9.361223223862738935e-27 4.877908592475649085e-21 3.525887135585909024e-24 2.885688813031784840e-23 1.373805849132910402e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.504764957117273437e-21 9.147229344684823986e-21 2.981250803487130831e-21 4.642280048837721856e-20 4.960000201612899104e+02 4.485316020941427328e-20 4.440443657559053810e-20 7.575265997002658282e-21 9.312965973018086978e-27 4.875424069062569857e-21 3.515031311160882975e-24 2.879601677905475288e-23 1.373768419579620057e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.508171150756636580e-21 8.659289412635174218e-21 2.983151750963789955e-21 4.627043928181317439e-20 4.965500293693140748e+02 4.502012250876649287e-20 4.443829270643707642e-20 7.184819031022947646e-21 9.264707100555442345e-27 4.872913959925277895e-21 3.504175331580759623e-24 2.873514338234095623e-23 1.373730990426163301e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.519137947185284427e-21 7.768818279994887723e-21 2.985052762317695698e-21 4.608242187665701670e-20 4.971500293338688721e+02 4.481398144667886463e-20 4.447523939533307726e-20 7.949128425988979357e-21 9.212596215026753442e-27 4.870175705053483910e-21 3.492332885113217471e-24 2.866873715615828666e-23 1.373690161198991515e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.534752081445616845e-21 8.053435771603461024e-21 2.987126558043878658e-21 4.629231306499709155e-20 4.977000200924247792e+02 4.526498247780257199e-20 4.450911883335516278e-20 8.685878540574222606e-21 9.165514203578790294e-27 4.867665680115108427e-21 3.481477714334650574e-24 2.860786580137721867e-23 1.373652736767211943e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.549671101346948613e-21 8.598641059443998655e-21 2.989027505630400424e-21 4.655491876171212396e-20 4.982500292691076993e+02 4.416273746029478590e-20 4.454301105516547866e-20 9.076690091736671461e-21 9.118430615447790638e-27 4.865155571120850617e-21 3.470622395788670823e-24 2.854699240813218242e-23 1.373615312740152443e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.547704089133285403e-21 8.052271107731144795e-21 2.990928516875980507e-21 4.656397355198210827e-20 4.988500292339037969e+02 4.398523393375542298e-20 4.457999702355929746e-20 8.903571612294957206e-21 9.067443680212943732e-27 4.862418534139636076e-21 3.458780676826962253e-24 2.848058618192280561e-23 1.373574507012620372e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.706370247914884540e-21 8.193977918238168517e-21 2.993002312602997785e-21 4.659604492337419415e-20 4.994000200240284926e+02 4.421485295771258271e-20 4.461391238326473557e-20 8.713624666433884195e-21 9.020905997970322468e-27 4.859925242557737084e-21 3.447926178862621881e-24 2.841971482364779813e-23 1.373537333770822736e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.751415450739871539e-21 7.654962435785870187e-21 2.994903260298631006e-21 4.650236641528060088e-20 4.999500291695828196e+02 7.711404817174603636e-20 4.464784044219844568e-20 8.628178429992573092e-21 8.974366762576161753e-27 4.857431867764557295e-21 3.437071540750701482e-24 2.835884143384798301e-23 1.373500160946994215e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.905143775231583887e-21 1.261185587354833746e-20 2.996805521072499514e-21 4.759229356694122693e-20 5.005500291346177733e+02 4.772662876138288039e-20 4.468486541394891089e-20 8.108551045554639840e-21 8.924407771241019437e-27 4.854727869865374026e-21 3.425230570741041342e-24 2.829243520761216346e-23 1.373459634164467761e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.756274072644161097e-21 9.605479143847951346e-21 2.998882175465379647e-21 4.682183684858868253e-20 5.011000199560962187e+02 8.985983868914608158e-20 4.471881644291713188e-20 7.415373392393934436e-21 8.878727004921705486e-27 4.852271244196103680e-21 3.414376765513152121e-24 2.823156384586702025e-23 1.373422520437953809e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.612786391184417811e-21 8.539854376221071350e-20 3.000785743668754989e-21 9.687470780683312960e-20 5.016500290707324439e+02 1.608595443884690243e-19 4.475278008724408829e-20 6.499133949608912354e-21 8.833134346404754367e-27 4.849814536817395717e-21 3.403522828001647509e-24 2.817069045948912796e-23 1.373385406793857057e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.595776629388576671e-21 2.466769531029223561e-19 3.002689375186411830e-21 2.508615945097958974e-19 5.022500290360038662e+02 4.586611544295028330e-19 4.478984378850523733e-20 8.105463623862089170e-21 8.784374855555916630e-27 4.847105201703449068e-21 3.391682629240110288e-24 2.810428423322714190e-23 1.373344921357386302e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.573405584576927664e-21 3.411947504992847706e-20 3.004766029580110107e-21 5.720885207141479136e-20 5.028000198886233534e+02 1.738577633394382215e-18 4.482383023641344852e-20 9.033479891930225443e-21 8.739679396393537318e-27 4.844611909838240515e-21 3.380829537462788449e-24 2.804341286803539048e-23 1.373307811699247389e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.555090945508148083e-21 4.511406509516472094e-20 3.006669597891267937e-21 6.452033626785338052e-20 5.033500289725498078e+02 8.356293680732402910e-20 4.485782921649523777e-20 8.276535123711164546e-21 8.695154636887038331e-27 4.842122388002593399e-21 3.369976321522642271e-24 2.798253948505636958e-23 1.373270719800055832e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.583998238828410426e-21 1.535430394870807330e-20 3.008573229302634886e-21 4.851158526358283532e-20 5.039500289380552545e+02 4.570680840837868193e-20 4.489493137569627530e-20 8.300868585599127777e-21 8.647002740921080688e-27 4.839460136500019263e-21 3.358136917197616545e-24 2.791613325876848150e-23 1.373230503691491677e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.627043199893714973e-21 8.662836975357757007e-21 3.010649883697143407e-21 4.686706984950853443e-20 5.045000198216051785e+02 6.447645245022171012e-20 4.492895299430102632e-20 7.258138144177476613e-21 8.602864232038653920e-27 4.837019779599500082e-21 3.347284560416556820e-24 2.785526189015344367e-23 1.373193640911623491e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.668906455445774434e-21 1.260730143390383152e-20 3.012553452115353978e-21 4.761700716374296891e-20 5.050500288750280902e+02 1.266863243702624463e-19 4.496298706257269112e-20 7.528210357815500414e-21 8.559235469432090122e-27 4.834586056932441951e-21 3.336432087863743017e-24 2.779438851055046606e-23 1.373156878448053315e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.693733512680560818e-21 2.033680687791977288e-20 3.014457083421145736e-21 5.029060669056170499e-20 5.056500288407651738e+02 7.303725609129394418e-20 4.500012741039803763e-20 7.483133045192088430e-21 8.512141132498723101e-27 4.831941320241363530e-21 3.324593502100933783e-24 2.772798228423694045e-23 1.373116928183964014e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.684281383242862755e-21 2.959895412625719118e-20 3.016530516224590061e-21 5.471998702065224380e-20 5.062000197550371468e+02 4.634126539315461019e-20 4.503418395351704445e-20 7.922718123775989828e-21 8.468972034321867214e-27 4.829517018185033361e-21 3.313741902735499446e-24 2.766711091222167354e-23 1.373080309089308806e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.657791451567513574e-21 1.400740682370363712e-20 3.018423683338182205e-21 4.820917078104453302e-20 5.067500287781606971e+02 7.025961233451875579e-20 4.506825286446887764e-20 7.906134744534240227e-21 8.426304695624041529e-27 4.827092636306791274e-21 3.302890196273929906e-24 2.760623753597214033e-23 1.373016715917940500e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.592579437658760994e-21 7.971331635773767518e-21 3.020316912785680770e-21 4.684060103858641102e-20 5.073500287441272008e+02 1.283016664276437012e-19 4.510543113383839854e-20 7.266802472738366749e-21 8.379965075611003652e-27 4.824447899614702492e-21 3.291052454184113774e-24 2.753983130963322404e-23 1.372937298425397083e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.551036981106794026e-21 1.247312286700590584e-20 3.022382220001214857e-21 4.774501716030805248e-20 5.079500287101740810e+02 1.062438837451526901e-19 4.514262272393132292e-20 8.348264701331575946e-21 8.333640325204488783e-27 4.821803162922258616e-21 3.279215016048905064e-24 2.747342508328540926e-23 1.372863805115611982e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.526137234629733826e-21 2.935443164210459520e-20 3.024447527217025796e-21 5.482558026109047441e-20 5.085000196656829985e+02 5.401003822570035331e-19 4.517672612964821477e-20 8.885448232166135385e-21 8.291978510324672439e-27 4.819378860684160534e-21 3.268364478748135641e-24 2.741255370670616799e-23 1.372827191499783787e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.520691903376674133e-21 2.178114860302598331e-20 3.026340694472562739e-21 5.129219511428388017e-20 5.090500286481346279e+02 1.072975810121932510e-19 4.521084179354132596e-20 9.499226751188938165e-21 8.250315329903946995e-27 4.816954478985195441e-21 3.257513846568818977e-24 2.735168033495807285e-23 1.372790578002556954e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.508860873579186579e-21 9.833808978713697075e-21 3.028233923780061619e-21 4.761821656218822113e-20 5.096500286144078018e+02 4.548637017311804214e-20 4.524807094735795637e-20 8.912632104396028457e-21 8.204975361073146960e-27 4.814317521753900286e-21 3.245677287738643268e-24 2.728527410858522004e-23 1.372750754269787173e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.523271975892706162e-21 6.363378257233898689e-21 3.030299230996651206e-21 4.694551567643380516e-20 5.102500285807602722e+02 4.667677380056621765e-20 4.528531329631810740e-20 8.812502388564334289e-21 8.160125363588286699e-27 4.811690070920853640e-21 3.233841045790351861e-24 2.721886788220358629e-23 1.372711073986188155e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.521248638014858051e-21 6.626607918280251283e-21 3.032364538213513884e-21 4.699870861698047189e-20 5.108500285471918119e+02 4.614427298480741650e-20 4.532256880789374914e-20 8.422776684504932419e-21 8.115275366097515962e-27 4.809062620087460177e-21 3.222005124216224965e-24 2.715246165581320098e-23 1.372671395272467861e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.501572257783380571e-21 6.482754632034127440e-21 3.034429845430648900e-21 4.694229499561697656e-20 5.114000195541647145e+02 4.676439596667536882e-20 4.535673067202426936e-20 7.523402012075573493e-21 8.074488562768988842e-27 4.806668096744867998e-21 3.211155990694150637e-24 2.709159027353807244e-23 1.372635233050203752e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.488856200468169974e-21 6.460723100021669261e-21 3.036322180846682382e-21 4.681880405539750127e-20 5.119500284858539771e+02 4.653739429966984748e-20 4.539090465778558512e-20 8.913357379131707433e-21 8.034062906289821118e-27 4.804275200743363171e-21 3.200306778543082490e-24 2.703071690740821141e-23 1.372599096421095112e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.459757648193098770e-21 6.596903976394961766e-21 3.038207940604336551e-21 4.711293598112460814e-20 5.125500284525079451e+02 4.579141010110876228e-20 4.542819728762647289e-20 9.052909418825365397e-21 7.989962908740748385e-27 4.801661966907318489e-21 3.188471784114381846e-24 2.696431068099321125e-23 1.372559634340025246e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.507487020115133266e-21 6.760615859347630052e-21 3.040265099545800768e-21 4.719998462258961290e-20 5.131500284192399022e+02 4.546869948674838740e-20 4.546550295627306665e-20 8.478221854659402575e-21 7.946639940350800512e-27 4.799034516072609977e-21 3.176637123931544878e-24 2.689790445456957708e-23 1.372519961645650975e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.558305246282152278e-21 6.821362507076229833e-21 3.042322258487532809e-21 4.713939444054883682e-20 5.137500283860495074e+02 4.515064780960794906e-20 4.550282163165562958e-20 8.139541017454865640e-21 7.903676979764425453e-27 4.796407065237561417e-21 3.164802801744292769e-24 2.683149822813734418e-23 1.372480290521812765e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.595090853164441794e-21 7.122026844741454668e-21 3.044379417429530795e-21 4.716126254130714757e-20 5.143000194439040342e+02 4.548449467198011742e-20 4.553704126160147982e-20 9.486795072615699735e-21 7.864294904016813077e-27 4.794037336561441440e-21 3.153955149009651124e-24 2.677062684023079248e-23 1.372444197168987187e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.612856120519660083e-21 7.194476357434228813e-21 3.046265115904983372e-21 4.745661236711700740e-20 5.148500283254014676e+02 4.650188081417735686e-20 4.557127287852161778e-20 1.015992827211124983e-20 7.825302342176602698e-27 4.791695363259580800e-21 3.143107434920764358e-24 2.670975347965601212e-23 1.372408297909874892e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.630886925145403077e-21 6.861198633688694079e-21 3.048150875490549682e-21 4.757979286584792803e-20 5.154500282924298062e+02 4.786613740628446287e-20 4.560862823298709095e-20 8.035768900551661522e-21 7.782817872461550051e-27 4.789140524690298585e-21 3.131274091246592836e-24 2.664334725319957579e-23 1.372369172979300968e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.654136510629967583e-21 7.195022852523564520e-21 3.050208034433297726e-21 4.725832017116587615e-20 5.160500282595347699e+02 4.607032181142166897e-20 4.564599648232028458e-20 8.052550785134706008e-21 7.740427661928743318e-27 4.786537539390335899e-21 3.120723510504705188e-24 2.658233907964223892e-23 1.372329840169106035e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.656035933758429726e-21 7.811862104178416313e-21 3.052265193376308330e-21 4.739493098988964220e-20 5.166500282267162447e+02 4.565623755952842570e-20 4.568337759064206875e-20 8.022807562748487703e-21 7.698649886436104655e-27 4.783927149922728377e-21 3.110933318114887197e-24 2.652452839225457125e-23 1.372290475132925878e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.676025815459470694e-21 7.323049800959494517e-21 3.054322352319581491e-21 4.734840323161753958e-20 5.172500281939737761e+02 4.763076988311145273e-20 4.572077152036260018e-20 9.075382335197084344e-21 7.656872110938168232e-27 4.781338342256264804e-21 3.101143991293987866e-24 2.646671770485958025e-23 1.372239721498393330e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.692611656362349255e-21 6.990324414191340749e-21 3.056379511263115330e-21 4.752438833482926851e-20 5.178000193124754560e+02 4.765979212552202729e-20 4.575505997374358276e-20 8.615881917460167188e-21 7.618923840599870823e-27 4.779011456754911373e-21 3.092171353507141742e-24 2.641372542759821204e-23 1.372168843359934196e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.666327248935986180e-21 7.421140025811791151e-21 3.058268096003861872e-21 4.753613792717843172e-20 5.183500281341429172e+02 4.609645657560879731e-20 4.578936025395233143e-20 7.582086603544611529e-21 7.581536737875479723e-27 4.776684496355549237e-21 3.083199167558130006e-24 2.636073144461644682e-23 1.372097963993641872e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.649630984129446285e-21 7.071944759692442609e-21 3.060156826401836604e-21 4.733869312301354920e-20 5.189500281016147483e+02 4.720254997785893704e-20 4.582679034057442708e-20 6.889822957359805380e-21 7.540751464012975391e-27 4.774137299696350327e-21 3.073412338183087377e-24 2.630292075720080826e-23 1.372041024848111720e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.627924636182076961e-21 7.180338162108769462e-21 3.062217226403990305e-21 4.728450620665839387e-20 5.195500280691617263e+02 4.683712847255217373e-20 4.586423312859969325e-20 7.600913612174519584e-21 7.500209155595050598e-27 4.771582461124859312e-21 3.063626406467064707e-24 2.624511006977792572e-23 1.372001917300107659e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.631830878701938219e-21 7.197924077487428437e-21 3.064277626406401674e-21 4.743222148776072420e-20 5.201500280367835103e+02 4.702870743689154173e-20 4.590168858694587758e-20 9.867099267820119275e-21 7.459865599489927443e-27 4.769027622553050066e-21 3.053841381039634554e-24 2.618729938234783740e-23 1.371962811028450851e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.655546246426007205e-21 7.320201997552219218e-21 3.066338026409069959e-21 4.790281707963916793e-20 5.207500280044799865e+02 4.758272001565697974e-20 4.593915668462160153e-20 7.852065842042602244e-21 7.419522043379782035e-27 4.766451802801271367e-21 3.044057270640519172e-24 2.612948869491055211e-23 1.371923941766448706e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.693224695798895516e-21 7.203842061234580017e-21 3.068398426411994784e-21 4.754829549211841580e-20 5.213500279722508139e+02 4.713920048881354271e-20 4.597663739072607745e-20 7.544323859822830809e-21 7.379993286698695941e-27 4.763874879862768757e-21 3.034274084121346042e-24 2.607167800746610512e-23 1.371885086175956872e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.661735287400268264e-21 6.517979686039982392e-21 3.070458826415175020e-21 4.743435896602653988e-20 5.219500279400957652e+02 4.698023046707150897e-20 4.601413067444877766e-20 8.189619207909861912e-21 7.340627435149843337e-27 4.761317079997049451e-21 3.024491830447429109e-24 2.601386732001451407e-23 1.371846317612240630e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.624201340022787503e-21 6.402167733944672843e-21 3.072519226418609540e-21 4.756037246598617774e-20 5.225500279080144992e+02 4.662634722903728187e-20 4.605163650506922970e-20 7.794579439097701877e-21 7.301305506455671327e-27 4.758794787138282801e-21 3.014710518699587866e-24 2.595605663255581421e-23 1.371807709542861647e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.661217436768412191e-21 6.465262103601101294e-21 3.074579626422297590e-21 4.753997957267744382e-20 5.231000191168033098e+02 4.684490560335359325e-20 4.608602729778263033e-20 8.242409830063953546e-21 7.265623149983029738e-27 4.756482722184139082e-21 3.005745294391629736e-24 2.590306434659517655e-23 1.371772320498326648e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.692563428544735923e-21 5.871859281433018905e-21 3.076468296337643868e-21 4.757282794460185307e-20 5.236500278493897440e+02 4.732567334367676164e-20 4.612042968003011303e-20 8.077821702726796336e-21 7.229939656600590460e-27 4.754170583563074931e-21 2.996780590828002199e-24 2.585007037219647142e-23 1.371736931399510141e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.713425192307475340e-21 5.425192992092045057e-21 3.078347648043356226e-21 4.752551403002818465e-20 5.242500278175164112e+02 4.853980233953840152e-20 4.615797089414885216e-20 7.928402924915269105e-21 7.191205512637163666e-27 4.751648290703434089e-21 2.987001998218946334e-24 2.579225968471773820e-23 1.371698326949064491e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.706498912066511898e-21 4.658346707077380452e-21 3.080393567926726290e-21 4.745502501379635299e-20 5.248500277857158380e+02 4.760506443333279728e-20 4.619552453823231396e-20 9.147962242307569840e-21 7.153241878285635409e-27 4.749125997843487055e-21 2.977224383449590217e-24 2.573444899723199316e-23 1.371659723776095696e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.700995214610101826e-21 4.662577903742072175e-21 3.082439487810344619e-21 4.771040211988068764e-20 5.254500277539879107e+02 4.926372924293611869e-20 4.623309058199109728e-20 9.348974664877612204e-21 7.115278243929511073e-27 4.746603704983235332e-21 2.967447756185768962e-24 2.567663830973924805e-23 1.371621121880712466e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.704552434680424586e-21 4.760751626717336390e-21 3.084485407694210085e-21 4.779538216879287882e-20 5.260500277223324019e+02 5.024061977329854543e-20 4.627066899522423725e-20 8.070613406852216826e-21 7.077510993366862506e-27 4.744081412122678922e-21 2.957672126220139194e-24 2.561882762223952638e-23 1.371582521263022006e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.700719747891847233e-21 4.846002041888832681e-21 3.086531327578323062e-21 4.760672936933533849e-20 5.266500276907489706e+02 4.979442907888368559e-20 4.630825974781880205e-20 8.596640870610040174e-21 7.039983722614989438e-27 4.741577101272234994e-21 2.947897503474248656e-24 2.556101693473285753e-23 1.371544002556619222e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.663063170302954551e-21 4.692169070600341981e-21 3.088577247462681670e-21 4.771837217102814048e-20 5.272500276592375030e+02 5.036623921344601186e-20 4.634586280974977256e-20 9.374582461012865911e-21 7.002456451858613562e-27 4.739108746971491013e-21 2.938123898000641449e-24 2.550320624721925915e-23 1.371505646361687333e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.621835729217562780e-21 5.156843254518530416e-21 3.090623167347285534e-21 4.794724152070726216e-20 5.278500276277975445e+02 5.325255468144589037e-20 4.638347815107958493e-20 8.895750851472390149e-21 6.965492284949273407e-27 4.736640392670452876e-21 2.928351319985019103e-24 2.544539555969876944e-23 1.371467291444906187e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.590822045748182407e-21 4.791823462248063549e-21 3.092669087232133148e-21 4.785327218012667202e-20 5.284500275964290950e+02 5.273994835246303506e-20 4.642110574195803427e-20 7.379324070483870155e-21 6.928769395302909851e-27 4.734156489222369581e-21 2.918579779748419647e-24 2.538758487217138838e-23 1.371402689234272418e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.603567716435117097e-21 5.497784556867306000e-21 3.094715007117224889e-21 4.770787611623029259e-20 5.290500275651318134e+02 5.312101411508125875e-20 4.645874555262185339e-20 8.419848432842330647e-21 6.892046505652191284e-27 4.731665923314547187e-21 2.908809287749469786e-24 2.532977418463715126e-23 1.371326841362169246e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.652714976465784210e-21 5.571975702998510671e-21 3.096760927002558875e-21 4.792647539718443316e-20 5.296500275339053587e+02 5.498969460393309566e-20 4.649639755339452020e-20 7.577519826444119100e-21 6.855728455178270937e-27 4.729175357406430637e-21 2.899039854586659850e-24 2.527196349709608745e-23 1.371252883196850549e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.687191702574390146e-21 6.326750681346365991e-21 3.098802148801117453e-21 4.791718729280159579e-20 5.302500275027496173e+02 5.371435372572058954e-20 4.653406171468598081e-20 8.078849243018950255e-21 6.819439300436121673e-27 4.726684791498020685e-21 2.889271491000663924e-24 2.521415280954821460e-23 1.371214786496102385e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.699711893361586291e-21 6.159641609422175561e-21 3.100839352969705903e-21 4.801410769698671953e-20 5.308500274716642480e+02 5.383529169395520670e-20 4.657173800699234266e-20 8.410662622804513988e-21 6.783306165741472043e-27 4.724194225589318081e-21 2.879504207876723898e-24 2.515634212199355914e-23 1.371176717966496507e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.683927586890144650e-21 5.598330797335365552e-21 3.102876557138533212e-21 4.803820945160033204e-20 5.314500274406491371e+02 5.193487835930206211e-20 4.660942640089563370e-20 8.248987559877843777e-21 6.747952874155773673e-27 4.721718755745774073e-21 2.869738016247057762e-24 2.509853143443213283e-23 1.371138650447909058e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.688429128314445918e-21 5.732136477313511662e-21 3.104913761307599006e-21 4.806254657780222294e-20 5.320500274097039437e+02 5.277981598189395693e-20 4.664712686706351960e-20 8.548181228795775452e-21 6.712599582565955620e-27 4.719265925683599725e-21 2.859972927293336593e-24 2.504072074686397094e-23 1.371100583940423733e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.689439319164791411e-21 5.928889918709170126e-21 3.106950965476902532e-21 4.817506570168047826e-20 5.326500273788284403e+02 5.288714466010948008e-20 4.668483937624901479e-20 9.811252851519844723e-21 6.677411580106521017e-27 4.716813095621141001e-21 2.850208952349196805e-24 2.498291005928909404e-23 1.371062518444124792e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.706905012155896673e-21 5.766066346134810380e-21 3.108988169646442285e-21 4.843232942826739055e-20 5.332500273480225133e+02 5.195286328045228160e-20 4.672256389929027787e-20 8.352074291318866119e-21 6.642489426210914613e-27 4.714343637189406960e-21 2.840446102902806769e-24 2.492509937170751388e-23 1.371024630849832316e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.705930352415892496e-21 6.443760429762533069e-21 3.111025373816218265e-21 4.828013278572906180e-20 5.338500273172857078e+02 5.197735851360731706e-20 4.676030040711025650e-20 8.153895100687803607e-21 6.607567272311286102e-27 4.711868637316196094e-21 2.830684390599495881e-24 2.486728868411927455e-23 1.370986803216226421e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.673997688739006842e-21 6.234751725904899713e-21 3.113062577986229344e-21 4.825411063009071114e-20 5.344500272866180239e+02 5.198785478162982234e-20 4.679804887071648278e-20 8.710784905901357172e-21 6.573027012193267056e-27 4.709398026482598072e-21 2.820923827244413379e-24 2.480947799652437604e-23 1.370948996013964385e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.661319033116084288e-21 5.935157038266703097e-21 3.115099782156474770e-21 4.834959795927657175e-20 5.350500272560190069e+02 4.883248532499467193e-20 4.683580926120077233e-20 8.597045336518813430e-21 6.538741299656065087e-27 4.706975666357687634e-21 2.811164424805267985e-24 2.475166730892285949e-23 1.370911403313994962e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.655649005602714202e-21 5.893829912364818460e-21 3.117136986326953414e-21 4.836044668811536863e-20 5.356500272254886568e+02 5.023522876644571691e-20 4.687358154973900156e-20 8.020835355827186754e-21 6.504455587114941456e-27 4.704553306232499591e-21 2.801406195415099126e-24 2.469385662131472786e-23 1.370873811625853649e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.696829555647649106e-21 6.277973068127775393e-21 3.119175296871987186e-21 4.834770534861041552e-20 5.362500271950265187e+02 5.219762948681477032e-20 4.691136570759078877e-20 8.799423833121277709e-21 6.470786646621011757e-27 4.702124889520204950e-21 2.791649151375130456e-24 2.463604593370002227e-23 1.370821126634691431e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.747300149847413030e-21 6.071521726867117498e-21 3.121216033202677538e-21 4.849488900421987265e-20 5.368500271646325928e+02 5.233895266583190289e-20 4.694916170609927137e-20 9.024456496756277580e-21 6.437271855419348152e-27 4.699687389643680180e-21 2.781893305157649439e-24 2.457823524607874567e-23 1.370745805448168325e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.777496263819547728e-21 6.331521942015014458e-21 3.123256769533599980e-21 4.860692968433617843e-20 5.375000372093011265e+02 5.048884755519828045e-20 4.699012133499449799e-20 8.838324182740234161e-21 6.400992030824349563e-27 4.697046723837214601e-21 2.771325674310892639e-24 2.451560603016779145e-23 1.370664207353351866e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.761263736153410339e-21 6.043511992813888568e-21 3.125467601501625663e-21 4.857492860839614163e-20 5.381500270990113677e+02 5.009665902514928084e-20 4.703109352020320350e-20 8.947374816073529572e-21 6.365146434539736137e-27 4.694433224602732542e-21 2.760759808051327598e-24 2.445297875621026544e-23 1.370616780087959352e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.744877179048121241e-21 6.600713150200122347e-21 3.127678364918055014e-21 4.870618600803278861e-20 5.387500270688315140e+02 4.975857222827548019e-20 4.706892682601292656e-20 8.301877632780461016e-21 6.332057678807641774e-27 4.692025817316417158e-21 2.751007839216858486e-24 2.439516806856836185e-23 1.370579423640965714e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.763933383743088926e-21 6.735430084415156345e-21 3.129719101249705698e-21 4.864742400948334580e-20 5.393500270387188493e+02 5.283034658068130622e-20 4.710677185396872645e-20 9.810946847565114735e-21 6.299158297783055493e-27 4.689618410029831693e-21 2.741257122080681821e-24 2.433735738091998423e-23 1.370542068206492879e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.773676519147743083e-21 7.792303915334590113e-21 3.131759837581584710e-21 4.912074904910674890e-20 5.399500270086730325e+02 5.149485895109746303e-20 4.714462857584096001e-20 9.983415235454333713e-21 6.266637589352403356e-27 4.687211002742978404e-21 2.731507670047453762e-24 2.427954669326516783e-23 1.370504713784624357e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.786132873858413173e-21 6.805486185894745521e-21 3.133800573913691298e-21 4.904547919366623398e-20 5.405500269786939498e+02 5.205898917976731378e-20 4.718249697322170919e-20 9.535876500099064776e-21 6.234116880918134479e-27 4.684803595455858042e-21 2.723272205955506754e-24 2.422785579542658026e-23 1.370467360375442714e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.793994114971445168e-21 7.006684234251709639e-21 3.135841310246024333e-21 4.902134903017687724e-20 5.411500269487812602e+02 5.098203723175122395e-20 4.722037701039264115e-20 9.286583182135387884e-21 6.201913861076580199e-27 4.682396188168470608e-21 2.715377977145154880e-24 2.417752805102810254e-23 1.370430007979030703e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.810392380476580908e-21 8.062865843891228471e-21 3.137882046578583815e-21 4.917257128241694329e-20 5.417500269189349638e+02 4.828956204813845517e-20 4.725826865719153831e-20 9.193986449248190940e-21 6.170007980310758178e-27 4.679988780880816854e-21 2.707488373563931072e-24 2.412720030662405592e-23 1.370392656595471458e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.821885685444445900e-21 7.601888798802693602e-21 3.139920919645522686e-21 4.911844142397858817e-20 5.423500268891546057e+02 4.906292037131044553e-20 4.729617188571499802e-20 9.579723781179058560e-21 6.138102099541429906e-27 4.677581373592898285e-21 2.699603435763611858e-24 2.407687256221447566e-23 1.370355306224847355e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.806339193509414610e-21 9.199511920599027912e-21 3.141947910994928084e-21 4.949972654931553027e-20 5.430000368324112969e+02 4.994024502447661809e-20 4.733724738447596354e-20 8.318642408469879942e-21 6.103861596793481546e-27 4.674986356189770893e-21 2.691066601615501092e-24 2.402235000236179415e-23 1.370315044564493596e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.754073044329593529e-21 7.858611723145601458e-21 3.144143851990602699e-21 4.907615345102122091e-20 5.436500268248560133e+02 4.819866215453425281e-20 4.737833514681245689e-20 1.045711974668902360e-20 6.069756239542853992e-27 4.672394371557323011e-21 2.682535606083270139e-24 2.396782911597480570e-23 1.370274830760048268e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.733678964397148709e-21 8.682278434173783591e-21 3.146339725586068482e-21 4.965938535500850642e-20 5.442500267952834747e+02 5.171739107327541265e-20 4.741627486762930330e-20 9.715453569177426391e-21 6.038289332984405320e-27 4.670001733638439892e-21 2.674665715945968870e-24 2.391750137154779580e-23 1.370228507028262029e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.736782319657918798e-21 9.642143355095879268e-21 3.148366716936175791e-21 4.972202465932202821e-20 5.448500267657758513e+02 4.866008600213847145e-20 4.745422605477403350e-20 9.881557981573009445e-21 6.007731194952351870e-27 4.667609095719298729e-21 2.666800665477858079e-24 2.386717362711534042e-23 1.370154579528476920e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.754497382531529255e-21 9.203904507685910767e-21 3.150393708286502777e-21 4.970843322179838813e-20 5.454500267363332568e+02 4.992713590677554044e-20 4.749218868075830081e-20 8.570754653320379872e-21 5.977173056916987320e-27 4.665216457799898017e-21 2.658940497625651056e-24 2.381684588267743074e-23 1.370080653025738409e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.766458370548091553e-21 1.036131624055882032e-20 3.152420699637049064e-21 4.972949594155844520e-20 5.460500267069553502e+02 4.936941151222498385e-20 4.753016271817331145e-20 7.660613321500190799e-21 5.946630223296073211e-27 4.662851115289930488e-21 2.651085255818572135e-24 2.376651813823409322e-23 1.370026504792434950e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.801079625602335823e-21 1.148451668126082355e-20 3.154447690987814274e-21 4.986491392708445443e-20 5.467000365831339650e+02 4.707291296722006478e-20 4.757131473186456923e-20 8.779537343156355793e-21 5.913635569932151651e-27 4.660314491382891904e-21 2.642580890796545463e-24 2.371199558400789191e-23 1.369986570969166426e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.825981273985502626e-21 1.182230309412287442e-20 3.156643631756877652e-21 5.016743646991929538e-20 5.473500266435241883e+02 4.950768109903765552e-20 4.761247881668021717e-20 9.328614018664451003e-21 5.880641922422283142e-27 4.657777944805759345e-21 2.634082674251555837e-24 2.365747469192166310e-23 1.369946639329624665e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.869518888681509412e-21 1.279020888420239000e-20 3.158839505581884944e-21 5.054311234549175204e-20 5.479500266143497811e+02 4.995273788846626807e-20 4.765048881036992527e-20 9.699342461480083517e-21 5.850528914219420067e-27 4.655401114028491983e-21 2.626243323694082149e-24 2.360714694746125741e-23 1.369909779650562934e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.871519770185342753e-21 1.488167218039447573e-20 3.160866460375263345e-21 5.121673685914559020e-20 5.485500265852392658e+02 5.156177938689576646e-20 4.768851010213769946e-20 9.083564571060498907e-21 5.820807985428848564e-27 4.653023065363381351e-21 2.618409085473045010e-24 2.355681920299549439e-23 1.369872920795029600e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.874787205062036603e-21 1.703722741887894542e-20 3.162885598007774347e-21 5.180751556306311672e-20 5.491500265561923015e+02 5.111176292384038600e-20 4.772654266498173709e-20 8.495003281413835317e-21 5.791087056635128108e-27 4.650656866691132702e-21 2.610580005614162756e-24 2.350649145852439757e-23 1.369836114508101291e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.859434115144109381e-21 1.948326049321374365e-20 3.164904735640499384e-21 5.259814760813191499e-20 5.498000363768630905e+02 5.127356557916485089e-20 4.776775792072548442e-20 9.298753888495427359e-21 5.759290719273702858e-27 4.648135616477622092e-21 2.602104249084577486e-24 2.345196890895417069e-23 1.369796425500608752e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.827618109965110640e-21 2.148458750494870690e-20 3.167092167897325309e-21 5.354125274391490744e-20 5.504500264934744109e+02 4.892733305630516431e-20 4.780898508902236650e-20 9.526381489527245443e-21 5.727730505519164564e-27 4.645614442691978124e-21 2.593634917828644826e-24 2.339744801215213773e-23 1.369756738663063362e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.833362051617768948e-21 2.646726678688646351e-20 3.169279533845467713e-21 5.580171396212993917e-20 5.510500264646275355e+02 5.125542361251192007e-20 4.784705316635579323e-20 9.166899356690352575e-21 5.698597558942944533e-27 4.643263532109042551e-21 2.585822482413729797e-24 2.334712026766426073e-23 1.369720104962116900e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.827265070902483995e-21 3.431444833250982863e-20 3.171298671478866073e-21 5.989729976348187481e-20 5.516500264358434151e+02 5.241036064262635397e-20 4.788513240309486523e-20 9.871461222559047440e-21 5.669832260758481215e-27 4.640899895858798104e-21 2.578015402847210223e-24 2.329679252317111751e-23 1.369683472085128971e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.853887790385670855e-21 4.202210203856733028e-20 3.173317809112475457e-21 6.475500051402186443e-20 5.523000362122023716e+02 5.282783336571450036e-20 4.792639809451351301e-20 9.768467020023145978e-21 5.638721966259914201e-27 4.638339251285262689e-21 2.569563706389387434e-24 2.324226997731774793e-23 1.369643786799511096e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.927433669611724299e-21 5.557946760000451666e-20 3.175505241220181743e-21 7.428747738980860378e-20 5.529500263736920260e+02 5.188156308149716454e-20 4.796767557235046803e-20 8.588783123437307531e-21 5.607709107992377492e-27 4.635832428438777760e-21 2.561118670642770853e-24 2.318774907675134125e-23 1.369565782744714031e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.945647900138886317e-21 6.493304520200972606e-20 3.177692607319350157e-21 8.141385586980124674e-20 5.535500263451051524e+02 5.031557612626517819e-20 4.800578997207729849e-20 8.916908861164618112e-21 5.579571178298520929e-27 4.633519175536944098e-21 2.553328875924252943e-24 2.313742133224165295e-23 1.369493228069624750e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.944415115037951945e-21 7.116369089127074655e-20 3.179711744953623460e-21 8.651921697624182621e-20 5.541500263165803517e+02 5.007503083920038071e-20 4.804391542087572132e-20 8.790472843713018800e-21 5.551433248601752893e-27 4.631205922634871199e-21 2.545544644143434770e-24 2.308709358772675721e-23 1.369431518828295302e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.953180376391622883e-21 6.233245142997069474e-20 3.181730882588105532e-21 7.942346629631720074e-20 5.548000360490254934e+02 5.063707491125361992e-20 4.808523104916179778e-20 7.627248416280672490e-21 5.521094886010549686e-27 4.628699861015805651e-21 2.537117936866545946e-24 2.303257104555686089e-23 1.369392074554189196e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.916668494181709193e-21 5.333113187448387142e-20 3.183921513376367360e-21 7.246851453412023620e-20 5.554500262549878471e+02 4.919672553571268203e-20 4.812655833926733122e-20 1.206251212464959464e-20 5.491060855804013839e-27 4.626193874679564657e-21 2.528698137314354685e-24 2.297805014126010223e-23 1.369352632432650415e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.914825363616949083e-21 3.962171337907157474e-20 3.186113025729750609e-21 6.378593254474375788e-20 5.560500262266576783e+02 5.026358140349452776e-20 4.816471860375649992e-20 9.717461988034741806e-21 5.463336719182029332e-27 4.623890318652329538e-21 2.520931862052016779e-24 2.292772239672888182e-23 1.369316376141608115e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.908067882155468545e-21 3.753469010536223769e-20 3.188135990595808927e-21 6.213037101260097791e-20 5.567000359259913012e+02 5.546770207954945773e-20 4.820607185413199263e-20 9.448046762071102880e-21 5.433653231235141520e-27 4.621399263517158592e-21 2.512524795840290546e-24 2.287319985733636420e-23 1.369277169165630322e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.913422375477097446e-21 3.344758226139051922e-20 3.190327568673203991e-21 5.974030353248829935e-20 5.573500261654849055e+02 5.482210809246065057e-20 4.824743667264652602e-20 8.470662622257941877e-21 5.404236530110630209e-27 4.618908282958620333e-21 2.504124833231122381e-24 2.281867895022702078e-23 1.369237964331412639e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.907969145792619822e-21 2.770460492873462226e-20 3.192519081139641585e-21 5.660525225308415131e-20 5.579500261373474359e+02 4.899264400359444436e-20 4.828563149165873640e-20 9.862605325810665409e-21 5.377082245669765700e-27 4.616608881868847797e-21 2.496377046964376735e-24 2.276835120567963732e-23 1.369201775571182236e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.903258364836214422e-21 2.643232397075582008e-20 3.194542046006349905e-21 5.625350433389115879e-20 5.585500261092704477e+02 4.866214902065792470e-20 4.832383716874756100e-20 9.069539816690227201e-21 5.350250264843949606e-27 4.614309480778843547e-21 2.488635213124235141e-24 2.271802346112717866e-23 1.369165587635893643e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.894415210587658765e-21 2.399039837078458126e-20 3.196565010873262103e-21 5.504509815359259322e-20 5.592000357653780611e+02 5.009259182215083091e-20 4.836523949252674883e-20 7.618252392853736708e-21 5.321278405886010453e-27 4.611823673274750278e-21 2.480254883427873922e-24 2.266350092536044104e-23 1.369112774171923494e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.875220184821683591e-21 2.202597370582524906e-20 3.198756588804915804e-21 5.403027003452903912e-20 5.598500260486433717e+02 5.267275443339380388e-20 4.840665326250016085e-20 9.471382546994591022e-21 5.292321584684511030e-27 4.609347519814692112e-21 2.471881926353639588e-24 2.260898001457954387e-23 1.369035115954618912e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.886734316197394178e-21 1.801585218269183960e-20 3.200948101418934550e-21 5.286216786518759813e-20 5.604500260207565816e+02 4.912689770863276334e-20 4.844489315408139173e-20 8.811745445049684747e-21 5.266003404089545113e-27 4.607061805635213138e-21 2.464159312621587358e-24 2.255865227001113376e-23 1.368963431223806811e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.887379573259630538e-21 1.668351808334348378e-20 3.202971066286487721e-21 5.234324336304412355e-20 5.611000356442690418e+02 4.910854249270845180e-20 4.848633245061826737e-20 9.172029542401458694e-21 5.237491618330929362e-27 4.604585578498022599e-21 2.455800009559637121e-24 2.250412973697846376e-23 1.368912559594438916e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.882010109396061051e-21 1.803354041498703455e-20 3.205154474431576261e-21 5.288809658143063524e-20 5.617500259605394604e+02 4.980175817990553344e-20 4.852778310166249302e-20 8.222163612708711624e-21 5.209164992871876698e-27 4.602109424912231301e-21 2.447448292565230533e-24 2.244960882342910988e-23 1.368873603213470824e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.886390009369035324e-21 1.762495913141972143e-20 3.207331884785439156e-21 5.263162616509566458e-20 5.624000355618765070e+02 5.036578420244084652e-20 4.856924753606662541e-20 1.076190011001148662e-20 5.181401870916463186e-27 4.599638920686496226e-21 2.439103741145277782e-24 2.239508629225650688e-23 1.368834691298760167e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.865334128936967005e-21 1.575719533984356932e-20 3.209509359742577615e-21 5.253466304279832227e-20 5.630500259006003034e+02 4.861821645680193351e-20 4.861072326273322563e-20 9.261397971973071276e-21 5.153639571703176212e-27 4.597215879778827773e-21 2.430766926503180131e-24 2.234056537682377302e-23 1.368795985565908168e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.851161828967816915e-21 1.558052664013330936e-20 3.211686770171657478e-21 5.223292976884251098e-20 5.636500258730293353e+02 4.732782068085996512e-20 4.864902020191684862e-20 8.149498947988195900e-21 5.128143539377067608e-27 4.594979193491074415e-21 2.423078005647453282e-24 2.229023763222887314e-23 1.368760257348414933e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.880931716746861278e-21 1.609339823526186587e-20 3.213696717273301136e-21 5.223976032045822126e-20 5.643000354421396878e+02 4.903497735525466716e-20 4.869052114537186007e-20 1.096506051215937711e-20 5.100674208433873351e-27 4.592539510751660659e-21 2.414755565857388844e-24 2.223571510375942813e-23 1.368721551945389533e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.886249886681951822e-21 1.683122110099662428e-20 3.215874192122483323e-21 5.302032165831412838e-20 5.649500258134931983e+02 4.867568849151086340e-20 4.873203329082313945e-20 9.184785673666347913e-21 5.073205688785712642e-27 4.590078008753635160e-21 2.406441090204505234e-24 2.218119418558972906e-23 1.368682848452563894e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.897847777583457874e-21 1.734398625004112247e-20 3.218051602660869490e-21 5.288558881715712728e-20 5.655500257861074260e+02 4.793385364164821207e-20 4.877036376334975954e-20 9.193785644793176144e-21 5.048232641653086831e-27 4.587805819508232213e-21 2.398772996315295934e-24 2.213086644097929502e-23 1.368647122304769017e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.882748507304472858e-21 1.734008711447431589e-20 3.220061549763133809e-21 5.292058095172176088e-20 5.662000353232061798e+02 4.892961174124045370e-20 4.881190095260067116e-20 8.583099892669090719e-21 5.021355842815745551e-27 4.585355161136165321e-21 2.394088413492215815e-24 2.208287335904816043e-23 1.368579764887921104e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.892730022534672212e-21 2.012633027120484617e-20 3.222239024505080066e-21 5.383497641627139556e-20 5.668500257269701024e+02 5.115473576422576318e-20 4.885344925504720523e-20 9.127030696106451425e-21 4.994479835109551276e-27 4.582908138439641920e-21 2.389828794215033589e-24 2.203540955812246462e-23 1.368503056174565432e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.890280634842832757e-21 2.236195111850200659e-20 3.224416435152038277e-21 5.483489228936144296e-20 5.675000352422896412e+02 4.990450650228734064e-20 4.889501108320091445e-20 8.245042273727732801e-21 4.967868221551301640e-27 4.580466339984456364e-21 2.385707182688195024e-24 2.198794436162682701e-23 1.368431642007673810e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.977202375608709228e-21 2.443737264717653973e-20 3.226581155075316659e-21 5.561530305783804520e-20 5.681500256681035808e+02 5.197710095193091117e-20 4.893658396312567167e-20 8.848533629436838262e-21 4.941284343461833413e-27 4.578057551935852028e-21 2.381724538234781062e-24 2.194048055909098900e-23 1.368393168506491794e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.004089405053024718e-21 2.565139873197201957e-20 3.228728651239976429e-21 5.628812232784549450e-20 5.688000351617429260e+02 5.358458558899436378e-20 4.897817030408192140e-20 9.154830074242035928e-21 4.914823182393245561e-27 4.575648693224129478e-21 2.377881324730662069e-24 2.189301536417848955e-23 1.368354694644261860e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.856729066447538884e-21 3.056517473853431833e-20 3.230876210402613044e-21 5.876731601176622589e-20 5.694500256095057011e+02 5.336444371855207058e-20 4.901976763647594881e-20 1.037067056558149760e-20 4.888968813744803902e-27 4.573247274070242272e-21 2.374178445180132037e-24 2.184555156003989732e-23 1.368316339641764606e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.819564596207833305e-21 3.149391755881608272e-20 3.233023706639789343e-21 5.948870389429305095e-20 5.700500255825506883e+02 5.485310308826872451e-20 4.905817654708855762e-20 9.370693368135268649e-21 4.865102893029271399e-27 4.571036747853761311e-21 2.370885378738469399e-24 2.180173817585588535e-23 1.368281033610612450e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.044941232193757075e-21 3.183495200616064730e-20 3.235006039901539548e-21 5.954320153598459532e-20 5.707000350446808170e+02 5.255194198355645871e-20 4.909979849050129945e-20 8.959203300896037117e-21 4.839346107739929300e-27 4.568641976151176680e-21 2.367453883815070461e-24 2.175427298324426034e-23 1.368242785590029286e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.665110937901146614e-21 2.611832216815384960e-20 3.237153598960073255e-21 5.668819387569604176e-20 5.713500255243424135e+02 5.132474053625871495e-20 4.914143133785580443e-20 7.576947314927756833e-21 4.813782236361059191e-27 4.566247274384002148e-21 2.364164571331607843e-24 2.170680917677634377e-23 1.368204539454318023e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.417697279994935353e-21 2.562604691327944309e-20 3.239301095302639675e-21 5.628539856196431166e-20 5.720000349650339331e+02 5.080743984078079096e-20 4.918307748871003714e-20 9.082071106372504763e-21 4.788217619252296563e-27 4.563852502760401709e-21 2.361017843131326427e-24 2.165934398573021568e-23 1.368166292970907568e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.015370653541752319e-21 2.168527578608180520e-20 3.241448654290342794e-21 5.485417144013233798e-20 5.726500254663983469e+02 5.007978120413709826e-20 4.922473448410413036e-20 8.784774483509095118e-21 4.762905681965932124e-27 4.561460371838191950e-21 2.358014453883917003e-24 2.161188017767750938e-23 1.368121111131275131e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.888803418386137147e-21 1.889740081512184081e-20 3.243596150704612865e-21 5.379708308447955580e-20 5.733000348857481185e+02 4.882642696657665449e-20 4.926640471967227333e-20 8.692618871843096767e-21 4.737771984417740646e-27 4.559079523383596895e-21 2.355154776707195734e-24 2.156441498818980469e-23 1.368045296896898625e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.835918517189825222e-21 1.835629361301985953e-20 3.245743709621805131e-21 5.363074161054497775e-20 5.739500254087168969e+02 4.945589324863122852e-20 4.930808574075226338e-20 9.518201889078999014e-21 4.712639017529616307e-27 4.556698744142490640e-21 2.352439502362449350e-24 2.151695117855949680e-23 1.367969485622042242e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.861707201629827219e-21 1.658574375169617645e-20 3.247891174227995901e-21 5.323176162472406049e-20 5.746000348068210997e+02 4.935474351587363191e-20 4.934977993906463759e-20 9.743462436319785513e-21 4.687858677340800210e-27 4.554325306772848082e-21 2.349868973364276988e-24 2.146948599062319192e-23 1.367914140882910556e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.804221039979354533e-21 1.597714127289052787e-20 3.250038597089925207e-21 5.312284238006411067e-20 5.752500253512960171e+02 5.012298714732892139e-20 4.939148486423212260e-20 1.012664156848763653e-20 4.663159036650752369e-27 4.551958289183141742e-21 2.347443814661119775e-24 2.142202217942245591e-23 1.367876338759720938e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.797892822633495156e-21 1.431194781164256850e-20 3.252185957665501636e-21 5.275699482700409823e-20 5.759000347282503753e+02 5.206710437177114023e-20 4.943320290407184088e-20 9.745565429397311937e-21 4.638478260978053084e-27 4.549591203012730445e-21 2.345164336413745679e-24 2.137455699303056546e-23 1.367838536309848839e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.792839656268126294e-21 1.320358995620420157e-20 3.254333380457558806e-21 5.243403062093428230e-20 5.765500252941341159e+02 4.973420126260975718e-20 4.947493161247859880e-20 9.725921446990309497e-21 4.614202370230129986e-27 4.547224185345060807e-21 2.343031096010795906e-24 2.132709318026650719e-23 1.367800735722585719e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.836309852325207948e-21 1.459111405135049309e-20 3.256480741103863507e-21 5.283737600394302927e-20 5.772000346500335581e+02 4.921361855716637207e-20 4.951667337337631765e-20 9.560198608299781080e-21 4.589925777711453101e-27 4.544857099251323339e-21 2.341044369649915815e-24 2.127962799541209282e-23 1.367762934811281688e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.859804510638019566e-21 1.481527968441647801e-20 3.258628163826361504e-21 5.290931242846257451e-20 5.778500252372293744e+02 5.027472216410756273e-20 4.955842574491916640e-20 8.997423438127172102e-21 4.565796881454927357e-27 4.542490081506043237e-21 2.339204645584770305e-24 2.123216418109177701e-23 1.367717042012505488e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.869604516134134490e-21 1.425139655669349985e-20 3.260775524543074368e-21 5.269465717744312116e-20 5.785000345721683743e+02 5.105042159607069799e-20 4.960019110714800639e-20 9.577521312239406678e-21 4.542082255169241544e-27 4.540122995488635790e-21 2.337512164595154231e-24 2.118469899776794151e-23 1.367641689219855642e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.861200361709830144e-21 1.586185564351650729e-20 3.262922947196326155e-21 5.329259502607507770e-20 5.792000345303857785e+02 5.121245314048703032e-20 4.964518168796493703e-20 8.555831782494865245e-21 4.516543795155157099e-27 4.537573862692815352e-21 2.335854612074314461e-24 2.113358338364128804e-23 1.367560546395860606e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.823633065225187317e-21 1.796746105311145107e-20 3.265235522857554854e-21 5.382493502164980368e-20 5.798500251501819776e+02 5.028036500478992651e-20 4.968697023151404541e-20 8.632730575121858418e-21 4.492983708872563339e-27 4.535215426180375794e-21 2.334469085611598743e-24 2.108611956694041691e-23 1.367509037724866342e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.835285216731559662e-21 1.838134363086941727e-20 3.267382883681968955e-21 5.401551271982679441e-20 5.805000344530567418e+02 5.129808057398566775e-20 4.972877167139347360e-20 9.360239157693399100e-21 4.469554802131583136e-27 4.532861944221691411e-21 2.333231713605113895e-24 2.103865438595798983e-23 1.367471478815995318e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.835927335359770611e-21 2.146564109046916484e-20 3.269529222887836572e-21 5.529752499614603957e-20 5.811500250939224088e+02 5.192855306111141486e-20 4.977058357651269822e-20 1.023769551100910141e-20 4.446126568043238819e-27 4.530508529832349749e-21 2.332142803025375154e-24 2.099119056771857585e-23 1.367433921607978291e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.827671898472192738e-21 2.365439640325919016e-20 3.271662894835619124e-21 5.637279361473086300e-20 5.818000343760733131e+02 5.240137706034015284e-20 4.981240831710100271e-20 9.042748797663027654e-21 4.423106986984088184e-27 4.528155047948699898e-21 2.331202499372441628e-24 2.094372538824945082e-23 1.367396363945438976e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.822158245822792853e-21 2.532472411650849263e-20 3.273796627975648047e-21 5.692803693969442781e-20 5.824500250379139743e+02 5.239266058874183814e-20 4.985424346628253265e-20 9.830166723513515908e-21 4.400232998665760126e-27 4.525801633483414905e-21 2.330411036470758055e-24 2.089626156847839708e-23 1.367358807981411321e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.840509790526976263e-21 2.281984302575832748e-20 3.275930299992283723e-21 5.602941364468415359e-20 5.831000342994331049e+02 5.289847085776131172e-20 4.989609139043927966e-20 9.872729020705144179e-21 4.377358355801370309e-27 4.523462164196294065e-21 2.329768520663383960e-24 2.084879639051585026e-23 1.367321310688602033e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.816889732359442527e-21 2.457687103047819259e-20 3.278064033064586116e-21 5.681101841835134829e-20 5.838000342583065958e+02 5.156406547381529874e-20 4.994117065544003867e-20 9.749812821859484804e-21 4.353008645449016931e-27 4.520982164341999386e-21 2.329243329293822714e-24 2.079768077634128658e-23 1.367281096472387617e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.805435345376264920e-21 2.037567053174647949e-20 3.280361866574478370e-21 5.514233285030077904e-20 5.844500249522337754e+02 5.277003346592510724e-20 4.998304133692599025e-20 9.493444624568355277e-21 4.330418804938761292e-27 4.518679340169228727e-21 2.328910582880169116e-24 2.075021695422720225e-23 1.367243755879413993e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.788769059448708250e-21 1.801672410666322994e-20 3.282495538696441726e-21 5.430741188674370825e-20 5.851000341821900292e+02 5.219387455705874100e-20 5.002492470103107824e-20 8.410556748996301803e-21 4.307903181173081034e-27 4.516360673097841894e-21 2.328727084810218043e-24 2.070275177856945014e-23 1.367182121256280268e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.774051629413634729e-21 1.872609979363698478e-20 3.284629271665135482e-21 5.440680612752764230e-20 5.857500248968553933e+02 5.206803938128561114e-20 5.006681833152203478e-20 8.695537835533513819e-21 4.285718715476894104e-27 4.514034001789665182e-21 2.328692880833038911e-24 2.065528795494101463e-23 1.367108062476874354e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.818115813585928905e-21 1.927056399327126152e-20 3.286762943855174443e-21 5.468096184192310598e-20 5.864000341064111126e+02 5.103091406517625258e-20 5.010872458505947936e-20 9.669628277236942546e-21 4.263533618542058121e-27 4.511707264278186794e-21 2.328807975572323034e-24 2.060782278077295769e-23 1.367034002202759477e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.851461583015408817e-21 1.491786976503736007e-20 3.288896676756901132e-21 5.351073065039486935e-20 5.871000340657459446e+02 5.149621415309254611e-20 5.015386650534766844e-20 8.859021267443695082e-21 4.239824946494595017e-27 4.509239652722940297e-21 2.329098863029883752e-24 2.055670716656470435e-23 1.366992316075417358e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.918000537972926107e-21 1.456603463252626440e-20 3.291194510268307423e-21 5.331767974863610577e-20 5.877500248121361892e+02 5.222263600019331227e-20 5.019579521774029111e-20 9.620680439350065912e-21 4.218064386724137550e-27 4.506949912593611508e-21 2.329523926040732419e-24 2.050924334061964572e-23 1.366955189659552855e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.950296469624289958e-21 1.582487103599064022e-20 3.293321972492392706e-21 5.384638436290782923e-20 5.884000339904816883e+02 5.100729373912504567e-20 5.023773646222845557e-20 8.653871471195184179e-21 4.196303209883874142e-27 4.504660107533530227e-21 2.330098141068594554e-24 2.046177816873063135e-23 1.366918062814163093e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.964872487478306080e-21 1.318878406932236786e-20 3.295448665349293621e-21 5.300514351553149579e-20 5.891000339500924383e+02 5.104488915169258399e-20 5.028291596874912127e-20 9.455667348947229033e-21 4.173138343694259370e-27 4.502194198584901389e-21 2.330883179096949668e-24 2.041066255450223004e-23 1.366878081321558156e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.975748353704800098e-21 1.208401531688500480e-20 3.297738917492692726e-21 5.292184712722340923e-20 5.897500247279915584e+02 5.195931489895312127e-20 5.032487949347372215e-20 9.391607910078050891e-21 4.151776484615196997e-27 4.499904458344575089e-21 2.331766736521857261e-24 2.036319872625632048e-23 1.366840956821780478e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.943309434613283990e-21 1.348289676012711899e-20 3.299865550147216205e-21 5.328571740019773102e-20 5.904000338753378401e+02 5.270167137407024414e-20 5.036685546018270228e-20 1.094842786178966024e-20 4.130414021826735314e-27 4.497623610154183397e-21 2.332799028962851168e-24 2.031573355663093795e-23 1.366778551261308689e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.890429621431035075e-21 1.382808395671991652e-20 3.301992242902693963e-21 5.370733752802701261e-20 5.911000338352215522e+02 5.214366192317653382e-20 5.041207226444851118e-20 8.427407670658799172e-21 4.107766650476724753e-27 4.495171632893574013e-21 2.334076793515253092e-24 2.026461794238260613e-23 1.366699249355034134e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.864404494086851006e-21 1.198694347909840538e-20 3.304282495046986443e-21 5.284462301776059764e-20 5.917500246444158165e+02 5.390164497487963251e-20 5.045407033446983589e-20 8.076356905192130918e-21 4.086799205018845387e-27 4.492895419777877210e-21 2.335417244928362835e-24 2.021715411185145326e-23 1.366627319345816234e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.844437944002157343e-21 1.208141748988199699e-20 3.306409127803900935e-21 5.285063754639819461e-20 5.924000337609713824e+02 5.102610121701700935e-20 5.049608075777211771e-20 9.502339898295928220e-21 4.065844086747577978e-27 4.490631343079762761e-21 2.336018977221843895e-24 2.017020236477734443e-23 1.366590611288136718e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.822578107071036383e-21 1.326158232734358528e-20 3.308535820458638263e-21 5.340711706830009857e-20 5.931000337211253282e+02 5.260445453991104110e-20 5.054133458140550843e-20 9.767654312255186206e-21 4.043564518123323705e-27 4.488193140971361322e-21 2.326271223111137808e-24 2.012570309183245164e-23 1.366551080788026599e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.798125552302133249e-21 1.361311898986263438e-20 3.310826072603814715e-21 5.358504600569893868e-20 5.938000336813731792e+02 5.285186377665027527e-20 5.058660129214907612e-20 8.659378825912735994e-21 4.021284949496079756e-27 4.485754938862633379e-21 2.316530851425330727e-24 2.008120381888159027e-23 1.366511551011425164e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.827205100577959700e-21 1.203168884689616881e-20 3.313116324749298489e-21 5.305709930369926085e-20 5.944500245324805974e+02 5.272465842611492900e-20 5.062864558593401913e-20 9.075609700235661896e-21 4.000733352023761116e-27 4.483490925785742126e-21 2.307493039228972362e-24 2.003988364467936416e-23 1.366474845952740375e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.834989776178345084e-21 1.219678274100117612e-20 3.315246147150302591e-21 5.320446739072657060e-20 5.951000336077961492e+02 5.408932097716886365e-20 5.067070211314570577e-20 1.074035592676329101e-20 3.980447507298939654e-27 4.481226849231271958e-21 2.298461495844122074e-24 1.999856231195705496e-23 1.366438147227661842e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.804538345554725703e-21 1.338286894894873752e-20 3.317377275715186032e-21 5.383481013728348011e-20 5.958000335683105959e+02 5.626432364834929864e-20 5.071600545413365772e-20 1.103661569033648374e-20 3.958601519226413899e-27 4.478798766411438511e-21 2.288742737274345066e-24 1.995406303898924590e-23 1.366369753443040027e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.794449473561460858e-21 1.329475797002084616e-20 3.319672305073884270e-21 5.391509960877093815e-20 5.965000335289178111e+02 5.837885070472680305e-20 5.076132154953644727e-20 1.021278409868875027e-20 3.936960895957283402e-27 4.476374185542295811e-21 2.279031730268474726e-24 1.990956376601553880e-23 1.366291362920024094e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.800155227518135509e-21 1.545047397711303675e-20 3.321967334432886820e-21 5.436829016950615313e-20 5.971500244215574185e+02 5.847365125735498746e-20 5.080341158409771519e-20 9.089382677487667013e-21 3.917009303851661191e-27 4.474122820439298663e-21 2.270021520084440312e-24 1.986824358917309361e-23 1.366223043787039218e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.842981032752523719e-21 1.520820963079186943e-20 3.324098403383802039e-21 5.414078033992018814e-20 5.978000334560043711e+02 5.709016686170084903e-20 5.084551373433859494e-20 9.417884046375604151e-21 3.897057154879866418e-27 4.471871392498755763e-21 2.261017908979846361e-24 1.982692225904881794e-23 1.366186565186415954e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.874088459063685475e-21 1.518427997406270820e-20 3.326229531814693042e-21 5.423067096489064057e-20 5.985000334168746576e+02 5.360434775636559219e-20 5.089086608325523224e-20 1.117692402723188126e-20 3.875882610960051156e-27 4.469446811628702008e-21 2.251329603210276916e-24 1.978242298605838944e-23 1.366147281639514419e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.953016354020150970e-21 1.543336836359987152e-20 3.328524561174558123e-21 5.467841254740463248e-20 5.992000333778362346e+02 1.434869166103908379e-19 5.093623105556565090e-20 1.043192157496870593e-20 3.854808144050250208e-27 4.467028773920786412e-21 2.241649441917964190e-24 1.973792371306215399e-23 1.366108104197590884e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.084342438245105224e-21 1.673186367512199637e-20 3.330819590534722250e-21 5.495943702868256962e-20 5.998500243116329784e+02 5.809702625580584008e-20 5.097836636090174964e-20 1.024088758308171563e-20 3.835239278927312790e-27 4.464789916259930657e-21 2.232668230670293389e-24 1.969660353360333755e-23 1.366071829900051524e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.158645179439612340e-21 1.756452733769620289e-20 3.332950659620575945e-21 5.522455467637825252e-20 6.005000333055777446e+02 5.534314910171128303e-20 5.102051366562714998e-20 1.049314809427726618e-20 3.815960288766482823e-27 4.462550996391898810e-21 2.223693970063244306e-24 1.965528220605380006e-23 1.366035555088127120e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.041672309748751189e-21 1.732954452284345202e-20 3.335081787918675958e-21 5.523209290949155911e-20 6.012000332667987550e+02 5.316739514479352779e-20 5.106591451947065645e-20 8.618686881275979945e-21 3.795198587788990701e-27 4.460169887262515758e-21 2.214037668621718415e-24 1.961078293304107536e-23 1.365966489734427930e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.896152540185451612e-21 1.846048998810120937e-20 3.337370212767188707e-21 5.531086587299072303e-20 6.019000332281101464e+02 5.094206778180948739e-20 5.111132786733751231e-20 8.721816750040820192e-21 3.774565144795889721e-27 4.457797665171404891e-21 2.204389930174191791e-24 1.956628366002260249e-23 1.365888538078207874e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.882951572722794574e-21 2.134427795364809589e-20 3.339651335554227593e-21 5.639550427148876408e-20 6.026000331895112367e+02 5.461454548856532649e-20 5.115675367595376295e-20 9.889634282307037232e-21 3.754331461701074983e-27 4.455420328301121783e-21 2.194750867644939565e-24 1.952178438699842848e-23 1.365818409437872583e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.861358141301616921e-21 2.255873595338527464e-20 3.341932458341558754e-21 5.709697595798979638e-20 6.032500241746092797e+02 5.983043387800494735e-20 5.119894532950040007e-20 1.096741985379595325e-20 3.735543301226557078e-27 4.453193839843879808e-21 2.185808301880195537e-24 1.948046420427836754e-23 1.365782337209842631e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.835063975502981833e-21 2.624695800985969005e-20 3.344050614526452321e-21 5.887924864682603315e-20 6.039000331180650392e+02 5.548758354042740044e-20 5.124114883803753240e-20 1.055582746459907916e-20 3.716821908108781410e-27 4.450967289871821519e-21 2.176873162310340377e-24 1.943914287993843802e-23 1.365746264478979265e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.811786982020761713e-21 2.700086184714346688e-20 3.346168829233090650e-21 5.918009413128955109e-20 6.046000330797212428e+02 8.476625679325927495e-20 5.128661006641926293e-20 7.844708138042482369e-21 3.696762649948305471e-27 4.448587733819723588e-21 2.167259527371700010e-24 1.939464360689804513e-23 1.365707418011566420e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.849766581545971238e-21 3.015599964017046543e-20 3.348449952021253121e-21 6.031193377838001813e-20 6.053000330414661221e+02 5.471790179585825105e-20 5.133208362822523970e-20 9.034536789753201571e-21 3.676703391785288273e-27 4.446228617926550353e-21 2.157655021957294136e-24 1.935014433385201574e-23 1.365668572116917618e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.884070575033542383e-21 3.214010795065943455e-20 3.350731074809704857e-21 6.153051034262002717e-20 6.060000330032994498e+02 5.590191213426179896e-20 5.137756949070705827e-20 8.108593215211065787e-21 3.656989235049183888e-27 4.443869502033079202e-21 2.148059768528218084e-24 1.930564506080036455e-23 1.365629726795081946e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.881915301233346209e-21 3.429813485318701969e-20 3.353012197598444730e-21 6.259523607377619641e-20 6.067000329652208848e+02 1.040557971572402289e-19 5.142306762122331165e-20 8.158647157562067706e-21 3.637433215170582201e-27 4.441521867534149389e-21 2.138473891624449150e-24 1.926114578774311212e-23 1.365557003144029390e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.907306604125959047e-21 4.033260528476530162e-20 3.355293320387471612e-21 6.613699801031642617e-20 6.074000329272299723e+02 5.760373332463134842e-20 5.146857798723922918e-20 8.221107933046402540e-21 3.617877195289531806e-27 4.439175713815328212e-21 2.128897517906249706e-24 1.921664651468028786e-23 1.365479910621468211e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.918740263297335467e-21 5.039434479212401396e-20 3.357574443176783999e-21 7.275106310741056563e-20 6.080500239837728031e+02 6.028870390569756797e-20 5.151084796085419628e-20 1.024421325715595270e-20 3.599977978750209492e-27 4.436988929286048449e-21 2.120013914374669706e-24 1.917532632741845176e-23 1.365416569119578024e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.940695961733496995e-21 5.092075034210298196e-20 3.359690545680622355e-21 7.340190464176783754e-20 6.087000328569072281e+02 5.613818961878321551e-20 5.155312958940253608e-20 1.035681354243080222e-20 3.582090823581652211e-27 4.434774613344601588e-21 2.111138477427603461e-24 1.913400500754887730e-23 1.365380697344543980e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.993924873699171313e-21 5.334225738025647247e-20 3.361802627894231761e-21 7.514781762522263243e-20 6.094000328191656308e+02 5.355122401714191571e-20 5.159867473566195932e-20 9.418932591256795117e-21 3.562850627567778419e-27 4.432389998088557212e-21 2.101589973064885353e-24 1.908950573447020443e-23 1.365342067284311778e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.012552668625584030e-21 5.658110745219029385e-20 3.364077146798387247e-21 7.739146747753889787e-20 6.101000327815104356e+02 5.407133820682663878e-20 5.164423199292149017e-20 1.009680303016217849e-20 3.543851675710209255e-27 4.430033224061631808e-21 2.092051481081869957e-24 1.904500646138603613e-23 1.365303551898639534e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.971627779317794959e-21 6.458563121440408791e-20 3.366351665702823723e-21 8.352894793910092069e-20 6.108000327439415287e+02 5.337573829758847336e-20 5.168980132915876367e-20 1.041971489179422857e-20 3.524852723850299004e-27 4.427699890853528160e-21 2.082523139056411507e-24 1.900050718829638414e-23 1.365265133153467571e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.908490026332161989e-21 6.089461744478735583e-20 3.368626184607540814e-21 8.077759138979616386e-20 6.115000327064586827e+02 5.275037691752502087e-20 5.173538271245569795e-20 9.987093209559711399e-21 3.505988088205255570e-27 4.425366557645137880e-21 2.073005086948059426e-24 1.895600791520126317e-23 1.365226714981636865e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.855683325623242838e-21 6.502998642563920679e-20 3.370900703512537014e-21 8.391332193780598013e-20 6.122000326690615566e+02 5.095594798068709921e-20 5.178097611099819932e-20 9.700500762657021060e-21 3.487365172533507521e-27 4.423045000390611524e-21 2.063497467146115465e-24 1.891150864210069084e-23 1.365153163182184267e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.849234668328119553e-21 5.046378770246458737e-20 3.373175222417811946e-21 7.319964742682023549e-20 6.129000326317499230e+02 5.114720963588836790e-20 5.182658149307575902e-20 8.998848428573500689e-21 3.468742256859485826e-27 4.420724348340394598e-21 2.054000424518742194e-24 1.886700936899468479e-23 1.365076925248663946e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.887959992787600546e-21 4.621983553164110228e-20 3.375449741323364860e-21 7.028237098818031095e-20 6.136000325945232134e+02 5.321914720490469855e-20 5.187219882708104397e-20 9.158969154858379078e-21 3.450347958468182016e-27 4.418403696289896306e-21 2.044514106463161745e-24 1.882251009588328028e-23 1.365012104857302213e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.889219756052047283e-21 4.363503201834799963e-20 3.377724260229193498e-21 6.866579808448788890e-20 6.143000325573816554e+02 5.359994644018971873e-20 5.191782808150958380e-20 9.640832113612254944e-21 3.432097182234485159e-27 4.416083044239115143e-21 2.035038662956938961e-24 1.877801082276645968e-23 1.364973913130110015e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.877336114316035817e-21 3.130220549025419078e-20 3.379998779135298988e-21 6.168102356254669279e-20 6.150000325203243392e+02 5.371122046777153117e-20 5.196346922495928337e-20 9.785401656763802147e-21 3.413846405998592142e-27 4.413762392188055623e-21 2.025574246610433056e-24 1.873351154964428764e-23 1.364935721867509484e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.799201440085783200e-21 3.019939844810441929e-20 3.382274197776956839e-21 6.118808293861439359e-20 6.157000324833514924e+02 5.302743207030672181e-20 5.200912222613016394e-20 9.976866701585096366e-21 3.395831911981917305e-27 4.411450163163003307e-21 2.016121012720342853e-24 1.868901227651674360e-23 1.364872262417907544e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.819245015070167636e-21 2.662775104506553486e-20 3.384553867819601141e-21 5.957862678108221318e-20 6.164000324464625464e+02 5.276894960119592566e-20 5.205478705382389376e-20 9.572195404086277831e-21 3.377856783395500191e-27 4.409142055176529302e-21 2.006679119324488490e-24 1.864451300338386575e-23 1.364796440518725578e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.827652572179988194e-21 2.500086517246320868e-20 3.386833537862518534e-21 5.884288869025593661e-20 6.171000324096572740e+02 5.286398276756484114e-20 5.210046367694349311e-20 1.018876102452755951e-20 3.359915472070077642e-27 4.406835030022733787e-21 1.997248727257758343e-24 1.860001373024566878e-23 1.364721701891128748e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.808325517569288855e-21 2.295257685915762111e-20 3.389113207905708643e-21 5.814747708036388917e-20 6.178000323729353340e+02 5.749430958124857415e-20 5.214615206449285890e-20 1.019805545597703756e-20 3.342278359593258187e-27 4.404564759871560790e-21 1.987830000209294989e-24 1.855551445710217622e-23 1.364683718113698085e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.858801847991501958e-21 2.969913452602924294e-20 3.391392877949169961e-21 6.116763598838246226e-20 6.185000323362967265e+02 5.890818624828142712e-20 5.219185218557651788e-20 9.265110788585805762e-21 3.324641247114338713e-27 4.402294489720118465e-21 1.978423104780936006e-24 1.851101518395338511e-23 1.364645734801130864e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.857440460815773745e-21 3.493338416020843458e-20 3.393672547992902865e-21 6.376819694116024846e-20 6.192000322997408830e+02 6.097388095975435200e-20 5.223756400939914514e-20 1.040045178224356184e-20 3.307118792022810602e-27 4.400014410199774530e-21 1.969028210546945622e-24 1.846651591079933367e-23 1.364607830427130489e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.906157578656714314e-21 3.607225940163480158e-20 3.395952218036905099e-21 6.461059467039177932e-20 6.199000322632674624e+02 6.145745272687142724e-20 5.228328750526526922e-20 8.421571698670993383e-21 3.289830587795404834e-27 4.397718711394660161e-21 1.959645490115031683e-24 1.842201663764003952e-23 1.364570051470330759e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.894420911333724172e-21 4.176860575071201262e-20 3.398231888081175909e-21 6.771573364918824615e-20 6.206000322268763512e+02 5.966743110945584187e-20 5.232902264444785750e-20 9.834737594332530106e-21 3.272542383565965771e-27 4.395423012589276461e-21 1.950044595845290368e-24 1.837951181960449466e-23 1.364532272978553773e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.889166342350777717e-21 4.047178925454032903e-20 3.400511558125714545e-21 6.715153655468501103e-20 6.213000321905673218e+02 5.875578202805475976e-20 5.237476939808080717e-20 8.313843651081680802e-21 3.255386703380441918e-27 4.393127313783622681e-21 1.940042624054047740e-24 1.834077247682275777e-23 1.364467074306761148e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.891316393352717674e-21 3.235798412777768245e-20 3.402791228170521004e-21 6.241468854806737971e-20 6.220000321543400332e+02 5.782864981763066076e-20 5.242052773222337656e-20 9.122498704384934329e-21 3.238342601698427624e-27 4.390831614977701828e-21 1.930085874887891061e-24 1.830203313403649523e-23 1.364391662936206875e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.952399178811951214e-21 3.128929712171571141e-20 3.405070898215593032e-21 6.202176634580192627e-20 6.227000321181941445e+02 5.572934912341378823e-20 5.246629761657585478e-20 9.600387136940706512e-21 3.221298500014432409e-27 4.388539469139484014e-21 1.920175051830248054e-24 1.826329379124572761e-23 1.364318956263426347e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.906939945029794207e-21 2.395030577057527053e-20 3.407337591445255891e-21 5.877809385146753034e-20 6.234000320821294281e+02 5.526923152762492253e-20 5.251207902093651861e-20 9.643007608162572792e-21 3.204514948897769753e-27 4.386293479950387010e-21 1.910310869684637120e-24 1.822455444845046960e-23 1.364281380872090261e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.883198827205908982e-21 2.307526002208089677e-20 3.409604194129391285e-21 5.847432489960319127e-20 6.241000320461456568e+02 5.632751575692944294e-20 5.255787191520127748e-20 9.771412275471399024e-21 3.187814949756239963e-27 4.384047490761029704e-21 1.900494054695735175e-24 1.818581510565073002e-23 1.364243805946045307e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.893213268440742820e-21 2.056106590032570373e-20 3.411870796813789237e-21 5.759231125577869035e-20 6.248000320102424894e+02 5.739923946844534662e-20 5.260367626936334238e-20 9.058907949471649037e-21 3.171114950612787725e-27 4.381786526597604652e-21 1.890725344667259899e-24 1.814707576284652943e-23 1.364206231485330795e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.880389804872599523e-21 2.002148480882092073e-20 3.414137399498448242e-21 5.732646918254828390e-20 6.255000319744196986e+02 5.586408484904696660e-20 5.264949205351283471e-20 1.054210414687430738e-20 3.154647411540173909e-27 4.379503104254566575e-21 1.881005489076332845e-24 1.810833642003788254e-23 1.364168657489984152e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.903881076569343187e-21 2.170961089770738526e-20 3.416404002183367550e-21 5.823014763112366200e-20 6.262000319386769434e+02 5.539828302136260102e-20 5.269531923783645521e-20 9.265561802901534187e-21 3.138190269523350285e-27 4.377219681911268196e-21 1.871335249183982152e-24 1.806959707722480404e-23 1.364131083960044687e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.919867111317837412e-21 1.971873290260170720e-20 3.418670604868545654e-21 5.733995262105582198e-20 6.269000319030141100e+02 5.579443977850709246e-20 5.274115779261712291e-20 9.071563328899776860e-21 3.121782005242150663e-27 4.374972238607401469e-21 1.861715398141406134e-24 1.803085773440730568e-23 1.364066527026960323e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.894855916802690056e-21 2.083643326821828846e-20 3.420937207553982555e-21 5.774404399032792212e-20 6.276000318674307437e+02 5.603596695397183542e-20 5.278700768823358989e-20 1.028456659326015206e-20 3.105635813169515671e-27 4.372738196167774349e-21 1.852146721091624153e-24 1.799211839158540509e-23 1.363991920057644506e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.863424485280776112e-21 2.181139578423246588e-20 3.423203810239676748e-21 5.834509227279567413e-20 6.283000318319266171e+02 5.462558938017092533e-20 5.283286889516015843e-20 9.199270971066616902e-21 3.089489621095052579e-27 4.370504660851026177e-21 1.842630015266097480e-24 1.795337904875912284e-23 1.363918919412143355e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.844618049777952512e-21 2.035638249413872469e-20 3.425470412925628233e-21 5.767511859691082412e-20 6.290000317965016166e+02 5.478341957116452126e-20 5.287874138396625370e-20 9.187263241202833118e-21 3.073453826660902701e-27 4.368282438741264832e-21 1.833166090075909819e-24 1.791463970592846188e-23 1.363881743846264365e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.874719022046675508e-21 1.990205474687572565e-20 3.427737015611834754e-21 5.755749491589809665e-20 6.297500416832062911e+02 5.324519088804452431e-20 5.292790361585034201e-20 9.149886501480520541e-21 3.056499057706912367e-27 4.365901454973947978e-21 1.823085541365770193e-24 1.787313271793156810e-23 1.363841912872558657e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.892146033450935213e-21 2.014709556849608249e-20 3.430161249518677937e-21 5.768237659688452395e-20 6.305000317208557590e+02 5.420982720853395068e-20 5.297707742797751941e-20 9.243614756328945701e-21 3.039544737461866911e-27 4.363520534219505715e-21 1.813067818409729860e-24 1.783162682841952494e-23 1.363784098583955090e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.923626120535304648e-21 1.798460086662185392e-20 3.432583695602290992e-21 5.702494649675884260e-20 6.312000316856772315e+02 5.540244249030697814e-20 5.302298518357633696e-20 9.122617582376104452e-21 3.023878486512802320e-27 4.361298312108961208e-21 1.803775181991249380e-24 1.779288748557522237e-23 1.363709903258379839e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.914631724403770678e-21 1.779928896209010070e-20 3.434844675199601776e-21 5.698963692618829126e-20 6.319000316505769206e+02 5.563515930432129092e-20 5.306890410013422476e-20 9.159323703938531207e-21 3.008294648910389171e-27 4.359076089998168437e-21 1.794538810981320612e-24 1.775414814272659104e-23 1.363635708293462242e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.889726815176828583e-21 1.722642693273069085e-20 3.437105654797163834e-21 5.686121442444929716e-20 6.326000316155541441e+02 5.577659236840719362e-20 5.311483414870449790e-20 1.041974641090583685e-20 2.992710811306249802e-27 4.356863058056144860e-21 1.785359578629818546e-24 1.771540879987366915e-23 1.363590768637581780e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.891250893397645567e-21 1.603225534377308108e-20 3.439366634394977166e-21 5.677180601867155553e-20 6.333000315806087883e+02 5.554666626040538363e-20 5.316077530043350588e-20 1.085214909048968828e-20 2.977366747173432832e-27 4.354652531850709409e-21 1.776238370779288381e-24 1.767666945701646259e-23 1.363553805828553306e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.833074131980125439e-21 1.537815923103657377e-20 3.441627613993040266e-21 5.671289541578232874e-20 6.340500414005191487e+02 5.477098276809505374e-20 5.321001089861315616e-20 9.878909903692411180e-21 2.960979597942426556e-27 4.352284079787834398e-21 1.766530931407998948e-24 1.763516247271609887e-23 1.363514202706026974e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.826395775208413712e-21 1.422702022731182245e-20 3.444050123972783458e-21 5.627881741703559509e-20 6.348000315059854302e+02 5.594817973870449641e-20 5.325925788013481247e-20 1.097813411603662642e-20 2.944621834313359501e-27 4.349915689981098487e-21 1.756892508865079163e-24 1.759365657945094029e-23 1.363474601046224875e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.865470065312686583e-21 1.390790352296448418e-20 3.446472570275443209e-21 5.645030604770703370e-20 6.355000314712817726e+02 5.491056762635647610e-20 5.330523374069498132e-20 9.410414935703833071e-21 2.929552488326779350e-27 4.347705163774899434e-21 1.747959571872922289e-24 1.755491723658035954e-23 1.363437639391811715e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.881808223809681239e-21 1.361375666840738357e-20 3.448733549874287214e-21 5.613853402918706174e-20 6.362000314366543989e+02 5.445592355843721244e-20 5.335122058586106451e-20 8.354103568731612145e-21 2.914483142338556565e-27 4.345500424806321312e-21 1.739088464119954329e-24 1.751617789370555289e-23 1.363382448560971457e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.863883917777578426e-21 1.420657046423557559e-20 3.450994529473377226e-21 5.616134213833351525e-20 6.369000314021031954e+02 5.537172045105029684e-20 5.339721838725252226e-20 8.622702534936358990e-21 2.899499337415623637e-27 4.343301472035277690e-21 1.730280136597873528e-24 1.747743855082653503e-23 1.363309031825233903e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.882732574554353121e-21 1.296758333874425508e-20 3.453246800149848464e-21 5.594608950773256195e-20 6.376500411667830122e+02 5.316970800196245057e-20 5.344651451611969277e-20 1.152595526900053046e-20 2.883674131380879417e-27 4.340945420418482862e-21 1.720913282813271069e-24 1.743593156958273286e-23 1.363230370409792335e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.895009271079082369e-21 1.290309576258710630e-20 3.455652652492572113e-21 5.649869507868799696e-20 6.384000313283200967e+02 5.496390796446951164e-20 5.349582186650158258e-20 9.718560124146456829e-21 2.867849338972447228e-27 4.338589430382240249e-21 1.711621049790219192e-24 1.739442567321451017e-23 1.363185220498281247e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.930324512193263843e-21 1.238992029566423095e-20 3.458058441953091756e-21 5.609037129123746544e-20 6.391000312940064987e+02 5.426105696411385250e-20 5.354185391799420008e-20 9.445560683221628575e-21 2.853240745357876468e-27 4.336390477610450330e-21 1.703016363846719585e-24 1.735568633032234147e-23 1.363148453613301600e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.956332050217925873e-21 1.377159184502327531e-20 3.460303874794985463e-21 5.640983227895483141e-20 6.398000312597679340e+02 5.440463643329303887e-20 5.358789680910090161e-20 9.755308040645430338e-21 2.838753183877440931e-27 4.334193652313224569e-21 1.694478532443567525e-24 1.731694698742602033e-23 1.363104950183851295e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.938657258491107574e-21 1.192210001484084486e-20 3.462549307637119159e-21 5.608347724862644388e-20 6.405000312256042889e+02 5.494380967355200766e-20 5.363395051190539883e-20 9.893002547450354647e-21 2.824265622395454594e-27 4.332006152419986166e-21 1.686008571221482961e-24 1.727820764452555264e-23 1.363031917072399316e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.928465945742522500e-21 1.193250570052996429e-20 3.464794740479494349e-21 5.615340646299878446e-20 6.412500409356712225e+02 5.599208710097926133e-20 5.368330637244577799e-20 9.399243393137252325e-21 2.808904239620637739e-27 4.329662372076027694e-21 1.677009979644756279e-24 1.723670066630413159e-23 1.362953666694467290e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.924636056590126293e-21 1.237612864168104448e-20 3.467200592647032099e-21 5.621157658673768250e-20 6.420000311526472387e+02 5.320479947270557778e-20 5.373267329537081849e-20 8.771198848360218895e-21 2.793605931712171659e-27 4.327346536890871017e-21 1.668091993363033387e-24 1.719519476686781281e-23 1.362896884920821918e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.905788322934810739e-21 1.168319846720259159e-20 3.469606382285386547e-21 5.600790254182831312e-20 6.427000311187172201e+02 5.444528045555855086e-20 5.377876079705031869e-20 8.153178699423862664e-21 2.779327325439102154e-27 4.325206640621538109e-21 1.659842087675465831e-24 1.715645542395441468e-23 1.362860499698117185e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.858103487210311561e-21 1.090337906352328872e-20 3.471851815128511044e-21 5.579950279970357422e-20 6.434500407957093557e+02 5.361051452833863629e-20 5.382815277254316667e-20 9.537141492622821460e-21 2.764319184085813358e-27 4.322913864925033640e-21 1.651082947464052052e-24 1.711494844756342053e-23 1.362821515434310245e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.825989375125864285e-21 1.060159688468965952e-20 3.474257667189953376e-21 5.600688190937031641e-20 6.442000310462582320e+02 5.578450602310534677e-20 5.387755571448055405e-20 8.605931442355399541e-21 2.749319379074835682e-27 4.320585913845829388e-21 1.642408251424029327e-24 1.707344254626911244e-23 1.362747298292773893e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.834072759746632615e-21 1.236096810679432608e-20 3.476657304811338627e-21 5.626386410686426146e-20 6.449000310125594524e+02 5.324515123376617391e-20 5.392367674291956678e-20 8.746270741862083085e-21 2.735382446157701836e-27 4.318409748147483640e-21 1.634388929973762937e-24 1.703470320334291906e-23 1.362674645265019634e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.849237032780746542e-21 1.185231292617922139e-20 3.478889035310090483e-21 5.622068721905141805e-20 6.456000309789335461e+02 5.491400603755450472e-20 5.396980838233969993e-20 8.937588743126876988e-21 2.721658308885933630e-27 4.316241356074762515e-21 1.626445242986855083e-24 1.699596386041269079e-23 1.362609766125014141e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.872973111077017811e-21 1.143214410372400758e-20 3.481120765809074052e-21 5.620878752084728886e-20 6.463500406126698863e+02 5.426918758467877533e-20 5.401924752040123800e-20 7.583834786414222113e-21 2.706953686510215771e-27 4.313948580510491192e-21 1.618019238227827677e-24 1.695445688641555268e-23 1.362570783487924368e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.910276140720917058e-21 1.049975581722075075e-20 3.483511936458426147e-21 5.587566175779416546e-20 6.471000309071234824e+02 5.528030595080765990e-20 5.406869749993152462e-20 9.990960408170679997e-21 2.692340486307622348e-27 4.311655864066306303e-21 1.609682936929523059e-24 1.691295098269147720e-23 1.362531802278552417e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.888655215440070567e-21 1.119282937981109746e-20 3.485903045450536398e-21 5.643304408897985025e-20 6.478000308737257456e+02 5.310766663096185955e-20 5.411486231156197821e-20 9.882390206768969732e-21 2.678809452470443392e-27 4.309529137356419562e-21 1.601984258298295727e-24 1.687421163974862118e-23 1.362474103165573901e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.864163420264712783e-21 1.077676906533054993e-20 3.488134775950247457e-21 5.637632095597553437e-20 6.485500404749043355e+02 5.333554402962200996e-20 5.416433689538488559e-20 9.730154416521071957e-21 2.664311729933375231e-27 4.307259877537468923e-21 1.593824728191287993e-24 1.683270466755329257e-23 1.362397058784006180e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.916785300397358312e-21 1.119474288984071285e-20 3.490525946495799451e-21 5.648044175823498568e-20 6.493000308024019205e+02 5.564324635426969977e-20 5.421382222698385344e-20 8.154572549694098618e-21 2.649999023805437284e-27 4.304990676033757840e-21 1.585759031217089139e-24 1.679119876200049759e-23 1.362320026758400945e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.956541152107220548e-21 1.315506165102641349e-20 3.492917055593260327e-21 5.670193020384510556e-20 6.500000307692300794e+02 5.612242934708431143e-20 5.426001994667200271e-20 1.008721929371132261e-20 2.636726475414794339e-27 4.302838366863907247e-21 1.579406503518246855e-24 1.675464977110395014e-23 1.362282491650904553e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.968653823379575951e-21 1.199768165748157390e-20 3.495148786093691353e-21 5.680060123424232462e-20 6.507500403380702210e+02 5.423109935799800042e-20 5.430952969651764526e-20 9.059925140799080860e-21 2.622505705746786668e-27 4.300530645113630213e-21 1.574132249527707865e-24 1.671851541115063866e-23 1.362243921939779694e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.003170636816255567e-21 1.239337234348564208e-20 3.497539956536142148e-21 5.676089296447810231e-20 6.515000306983877181e+02 5.402399520330871503e-20 5.435905010136328248e-20 1.045237276426149354e-20 2.608539527319705514e-27 4.298234266092057969e-21 1.568860222188364229e-24 1.668238197663575013e-23 1.362205353558562875e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.070866171642918017e-21 1.313157288249143143e-20 3.499929999526751157e-21 5.721420566075258280e-20 6.522500402453035804e+02 5.616228458541797968e-20 5.440858366380674901e-20 8.679280483862710838e-21 2.594607642662848434e-27 4.295965006437286838e-21 1.563590172760797113e-24 1.664624761773871731e-23 1.362166784532806706e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.071925026920350228e-21 1.202516977272354196e-20 3.502315871836430650e-21 5.671947440776350504e-20 6.530000306278707285e+02 5.545525929644119987e-20 5.445812781855700163e-20 8.897438411153521757e-21 2.580704024203499835e-27 4.293695804766955732e-21 1.558322392158104354e-24 1.661011418215187198e-23 1.362128216834727207e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.044341687141581577e-21 1.244845196773475303e-20 3.504701683181967604e-21 5.689085879352397322e-20 6.537000305950734855e+02 5.518192957286277707e-20 5.450438029054667237e-20 9.188903038268991732e-21 2.567878658950751362e-27 4.291585111984218122e-21 1.553407678767542995e-24 1.657638921138739405e-23 1.362068362278735276e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.004237242976538329e-21 1.387405483885598282e-20 3.506928468888086562e-21 5.730830246983016615e-20 6.544500401100148110e+02 5.521479974871857800e-20 5.455394854362508958e-20 8.387668845633471319e-21 2.554137021203826939e-27 4.289327430281078165e-21 1.548143951771744177e-24 1.654025485403084951e-23 1.361991725153120798e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.947441135126794438e-21 1.159349748671746400e-20 3.509314341096051374e-21 5.672086843216321068e-20 6.552000305250298879e+02 5.699509380909002461e-20 5.460352729784367858e-20 9.144826451433948744e-21 2.540489548822279560e-27 4.287069959341281208e-21 1.542882557506371181e-24 1.650412141688070836e-23 1.361915604668726394e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.933348369237163619e-21 1.315491222102569890e-20 3.511700152544808394e-21 5.722349772017922052e-20 6.559500400182929525e+02 5.656791640075844214e-20 5.465311904498746534e-20 9.326781274411382928e-21 2.527018504525806721e-27 4.284823738016280522e-21 1.537623250711795204e-24 1.646798706056859056e-23 1.361877427799185827e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.924624891782345340e-21 1.192347878084608521e-20 3.514086024683812125e-21 5.702972291919032089e-20 6.567000304553062051e+02 5.661280617618068586e-20 5.470272123164150919e-20 9.637480953011547297e-21 2.513547802501781733e-27 4.282577573763296255e-21 1.532366321670048652e-24 1.643185362235861195e-23 1.361839252242027151e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.928752622385853716e-21 1.244547742119005041e-20 3.516471836202548111e-21 5.724019276294476188e-20 6.574000304228774212e+02 5.816986318108115912e-20 5.474902772160597108e-20 1.118722989775360222e-20 2.501083733684634115e-27 4.280481127159910155e-21 1.527461837382175403e-24 1.639812865157638405e-23 1.361791437434271602e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.894367183964245072e-21 1.210919229845103492e-20 3.518698621909839929e-21 5.749251968923921492e-20 6.581500398845237214e+02 5.409248150538749424e-20 5.479865369610297058e-20 1.078957004445619520e-20 2.487816576023278904e-27 4.278234905929599018e-21 1.522209179732412888e-24 1.636199429678751297e-23 1.361715190462562168e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.916632593158331092e-21 1.110920684340415597e-20 3.521084493948266483e-21 5.726212617474221663e-20 6.589000303536190586e+02 5.443428325499661105e-20 5.484829002048796795e-20 9.489565422606176356e-21 2.474549754327242398e-27 4.275988741580531912e-21 1.516958968086439906e-24 1.632586085703186802e-23 1.361638945758366666e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.947500488651085741e-21 1.102163073862147561e-20 3.523470314258995292e-21 5.706320289468864090e-20 6.596500397938289098e+02 5.468075267722766348e-20 5.489793917581101213e-20 1.039130707682963910e-20 2.461469840103338736e-27 4.273750386472934227e-21 1.511710960784651836e-24 1.628972650327577452e-23 1.361589230442489477e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.983031216037466411e-21 1.008781567264687301e-20 3.525862247508383809e-21 5.709649959666791639e-20 6.604000302846752675e+02 5.491634747247956900e-20 5.494759862043501850e-20 1.051074628485356450e-20 2.448441019788925913e-27 4.271515566323442225e-21 1.506465447590845114e-24 1.625359306247219399e-23 1.361551248838058864e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.980354099914261611e-21 9.692240581516385023e-21 3.528254120324382979e-21 5.709749751163276387e-20 6.611500397035457581e+02 5.440616570347239561e-20 5.499727083108002789e-20 1.010309172721672397e-20 2.435418939660807937e-27 4.269282711979512765e-21 1.501222188342027345e-24 1.621745870974419960e-23 1.361511244433134824e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.992715916138017126e-21 9.155066531136651965e-21 3.530646053505716204e-21 5.698337157264380906e-20 6.619000302160441151e+02 5.461994756890421961e-20 5.504695327085596375e-20 1.112580149563131177e-20 2.422654678053864887e-27 4.267085770074214129e-21 1.495981472626166724e-24 1.618132526789745893e-23 1.361435385626504771e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.989679049934114073e-21 8.441021890493361099e-21 3.533037926390768238e-21 5.711133289411569479e-20 6.626500396136711970e+02 5.562392342891575315e-20 5.509664841216550974e-20 8.985487121356835802e-21 2.409890095036557825e-27 4.264888772848841561e-21 1.490743061799653873e-24 1.614519091619294103e-23 1.361359525246742979e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.051878133714645608e-21 7.145577089917958823e-21 3.535429859504352363e-21 5.660557590969430114e-20 6.634000301477232142e+02 5.493243905339621789e-20 5.514635372284970844e-20 9.611296200692808199e-21 2.397188587773882885e-27 4.262680815139915983e-21 1.485507245295387427e-24 1.610905747330777747e-23 1.361299403710953846e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.068893688670662180e-21 6.675094608164438554e-21 3.537821732458142793e-21 5.669986402826296834e-20 6.641500395242027253e+02 5.401830145197692271e-20 5.519607167100651324e-20 9.302321761496222471e-21 2.384671684878377490e-27 4.260457169249851333e-21 1.480273786012862136e-24 1.607292312262211929e-23 1.361261613202011971e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.087075392513502845e-21 6.280623761717023360e-21 3.540213665504283259e-21 5.665226860765297012e-20 6.649000300797106320e+02 5.347118475076264275e-20 5.524579972919222099e-20 8.923464091858349247e-21 2.372155096085977154e-27 4.258233579160656990e-21 1.475042973251384640e-24 1.603678967870324069e-23 1.361223823984201118e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.015755393908227983e-21 6.286885735046034443e-21 3.542605538526501378e-21 5.663789012701611437e-20 6.656500394351375007e+02 5.522938302083385523e-20 5.529554036121257337e-20 9.665978127021577168e-21 2.359718585373812705e-27 4.256046885638100967e-21 1.469814571478260872e-24 1.600065532903186663e-23 1.361157675722040247e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.961488062719922164e-21 5.501905968324029072e-21 3.544997471505499864e-21 5.672460023887571589e-20 6.664000300120042084e+02 5.495509970885854382e-20 5.534529104432338906e-20 9.446107121242202383e-21 2.347374242864619313e-27 4.253871912965188048e-21 1.464588869881420667e-24 1.596452188408395440e-23 1.361082576497414901e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.964942492265152336e-21 5.066649761203889014e-21 3.547389344595835717e-21 5.669562875154096425e-20 6.671500393464726812e+02 5.506139793021926745e-20 5.539505423805075265e-20 9.692649933547294282e-21 2.335029591617865687e-27 4.251693383927905744e-21 1.459365634521718773e-24 1.592838753542232411e-23 1.361010977662044825e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.981559068542169723e-21 4.805374114910859654e-21 3.549771041231262485e-21 5.676361573488739605e-20 6.679000299446018971e+02 5.438607681512547217e-20 5.544482742433422408e-20 1.081722992528511900e-20 2.322851516893755831e-27 4.249480911663424589e-21 1.454145154498697034e-24 1.589225408945001557e-23 1.360973381655450982e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.004151689404271859e-21 4.560408699819236672e-21 3.552150405094123649e-21 5.699547057983711399e-20 6.686500392582057657e+02 5.544625881821162167e-20 5.549461305843273738e-20 1.117622590435775233e-20 2.310751366634280391e-27 4.247268384188293167e-21 1.448927197493568732e-24 1.585611974179361222e-23 1.360935792683421774e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.988183216790111267e-21 4.727996324850135012e-21 3.554529828332294579e-21 5.712611746388246935e-20 6.694500392112917098e+02 5.545045076738473375e-20 5.554772938944910613e-20 1.071085022890165479e-20 2.297844700724493809e-27 4.244932225161446676e-21 1.443364403049976565e-24 1.581757691851717646e-23 1.360877380908257197e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.992139194086698291e-21 4.089931391257643450e-21 3.557067848120023973e-21 5.703939981364196118e-20 6.702000298418377042e+02 5.562962795685418137e-20 5.559753684599524466e-20 1.027426105306373525e-20 2.285907144420295832e-27 4.242768073093204747e-21 1.438152150974234198e-24 1.578144347098307380e-23 1.360802667414085261e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.017314902556601294e-21 4.656981507221295994e-21 3.559447212085728291e-21 5.705196193035387394e-20 6.709500391236296082e+02 5.718638585368088191e-20 5.564735665486259524e-20 1.031457163137029702e-20 2.273978425367034070e-27 4.240603867205447109e-21 1.432942512074562658e-24 1.574530912485932700e-23 1.360727952327920073e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.009264172737672184e-21 4.525788952381232697e-21 3.561826635222975226e-21 5.709693301251626361e-20 6.717000297751966400e+02 5.679325811545276567e-20 5.569718630978640078e-20 8.701684727631874422e-21 2.262083326919681450e-27 4.238439715076546662e-21 1.427735775335062716e-24 1.570917567631245955e-23 1.360683588792900501e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.011275557501746636e-21 3.908560969726331602e-21 3.564205999255368630e-21 5.683078041358699670e-20 6.724500390363584756e+02 5.587460743327002659e-20 5.574702825527102193e-20 1.000869229495235281e-20 2.250381760627052179e-27 4.236275509248319067e-21 1.422531712669482571e-24 1.567304133118263730e-23 1.360646187756623693e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.998872787914648548e-21 3.748572485375055583e-21 3.566585422327165544e-21 5.708301442925468020e-20 6.732500389899729498e+02 5.383004485305368802e-20 5.580020448821523187e-20 1.014105931568295142e-20 2.237900244763077013e-27 4.233961767306514789e-21 1.416983905963599305e-24 1.563449850788074034e-23 1.360598903466989931e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.993105252279413549e-21 3.501128561220900722e-21 3.569123442116572603e-21 5.714237328754629200e-20 6.740000296735898928e+02 5.496415530908147782e-20 5.585006795001171726e-20 1.110433911952883897e-20 2.226288979900351738e-27 4.231771200458326650e-21 1.411785863821553152e-24 1.559836505778975820e-23 1.360524560753746333e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.013986672649404208e-21 3.043066069072739203e-21 3.571502806250645328e-21 5.734429023792527961e-20 6.747500389032965131e+02 5.499494841632812891e-20 5.589994360845605194e-20 1.007158732164788122e-20 2.214812423574086220e-27 4.229580579440867153e-21 1.406590592498678534e-24 1.556223071417540090e-23 1.360450216468403549e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.039611506836180165e-21 3.124844512260623838e-21 3.573879476116089679e-21 5.720732706805633366e-20 6.755500388572263546e+02 5.611130625375745045e-20 5.595315570425535008e-20 1.078861023367624196e-20 2.202570914845084492e-27 4.227271317550782282e-21 1.401052270325898110e-24 1.552368789085830773e-23 1.360392310883653358e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.002938254511417713e-21 2.701045513400315875e-21 3.576412980903142717e-21 5.736696449477854323e-20 6.763000295726742479e+02 5.549118314100388289e-20 5.600305269625615657e-20 1.005860685603925895e-20 2.191203327762892850e-27 4.225128486935216547e-21 1.395863221808614068e-24 1.548755443923375804e-23 1.360355279768539481e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.950569962480570668e-21 2.943726901727431289e-21 3.578788112374711462e-21 5.729308839483912428e-20 6.770500387711384747e+02 5.527754962746691615e-20 5.605296179193384245e-20 9.661252540904206226e-21 2.179896585318120831e-27 4.222985603511032409e-21 1.390677045125129681e-24 1.545142009712461244e-23 1.360318248011877274e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.926576332049680579e-21 3.779689658928431305e-21 3.581163302379796839e-21 5.732173340897993168e-20 6.778000295072286008e+02 5.771569653881839712e-20 5.610288050375169429e-20 8.678078630654281651e-21 2.168590121202347092e-27 4.220842772836489582e-21 1.385494029430379394e-24 1.541528664450555044e-23 1.360249196591524214e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.026136377419412459e-21 6.944970156512433886e-21 3.583538433916737363e-21 5.751250183638914738e-20 6.785500386854311046e+02 5.436815183879702642e-20 5.615281125911546208e-20 9.893407234063758659e-21 2.157464029193723254e-27 4.218699889470196942e-21 1.380313953857101761e-24 1.537915230337258531e-23 1.360175219468418682e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.034133080822462032e-21 1.121459681614696879e-20 3.585913623857656171e-21 5.842455920643762556e-20 6.793500386398752653e+02 5.541761149963246531e-20 5.620608196585379479e-20 1.056892889068650104e-20 2.145640555688604818e-27 4.216416556808198068e-21 1.374792028034701384e-24 1.534060948003071566e-23 1.360104729068122891e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.989576108724824617e-21 1.045473473062220508e-20 3.588447128646337974e-21 5.845161283234840182e-20 6.801500385944266327e+02 5.305552464143870259e-20 5.625936491105461218e-20 1.091006323036622637e-20 2.133839066368691112e-27 4.214142047133492713e-21 1.369273674532741453e-24 1.530206665668367971e-23 1.360065423372325649e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.920656873334847596e-21 7.955615050022251050e-21 3.590980633435359072e-21 5.816898230691472796e-20 6.809000293728881843e+02 5.503346837398017722e-20 5.630932814668055388e-20 9.782017345464677274e-21 2.122960695451192605e-27 4.212009720410415907e-21 1.364741190166037822e-24 1.526893799082308811e-23 1.360028575013742081e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.941090489031272069e-21 7.416777709893700704e-21 3.593355765106485004e-21 5.794573209330784454e-20 6.816500385094980174e+02 5.714343444189394708e-20 5.635930330388572372e-20 9.375075531281373897e-21 2.112082058254758433e-27 4.209898421811696725e-21 1.360564222685437585e-24 1.523748083545846396e-23 1.359970645903839622e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.985035119225406418e-21 6.439809334040713937e-21 3.595730954915685250e-21 5.781156371187139344e-20 6.824500384643553161e+02 5.659746010567174309e-20 5.641262124476307178e-20 1.088183768735632059e-20 2.100527674294733198e-27 4.207663127820183642e-21 1.356109095361488254e-24 1.520392694705466130e-23 1.359892125776560503e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.054758305546227674e-21 6.687607677747636952e-21 3.598267706983458140e-21 5.815707914248495907e-20 6.832000292740041232e+02 5.669739482153656781e-20 5.646261719843458724e-20 1.218181177800477380e-20 2.089803506642745414e-27 4.205567565263811844e-21 1.351932701150694841e-24 1.517247056036608807e-23 1.359818514330822617e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.133483458860600486e-21 5.531482879879243205e-21 3.600649379183656262e-21 5.834443886552209716e-20 6.839500383799975225e+02 5.607637948204874488e-20 5.651262498238871627e-20 1.125798780865473471e-20 2.079079077370129438e-27 4.203447696290738431e-21 1.347756436313928242e-24 1.514101340628559159e-23 1.359778891455187464e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.120992094655535478e-21 5.075918422571702653e-21 3.603031109485759583e-21 5.816513270516862992e-20 6.847500383351577966e+02 5.719078695259516825e-20 5.656597763145622756e-20 1.034368855810847308e-20 2.067781687659744328e-27 4.201184281783455646e-21 1.343302065483473062e-24 1.510745951786908183e-23 1.359739778821864126e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.087199104540511722e-21 5.597275944714482383e-21 3.605571590820800180e-21 5.809377621281620459e-20 6.855500382904227763e+02 5.539630400062602480e-20 5.661934228684425769e-20 9.270105640479602553e-21 2.056626132727993630e-27 4.198924164036673614e-21 1.338847962875082658e-24 1.507390562944818161e-23 1.359689071099362992e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.035450735589556560e-21 6.578293106441701391e-21 3.608112072156173301e-21 5.806548199849493052e-20 6.863000291417741892e+02 5.733918675822502081e-20 5.666938191761265653e-20 1.045094958231265945e-20 2.046167926967482315e-27 4.196812539309567598e-21 1.334672538366741390e-24 1.504244924101050217e-23 1.359616174621487665e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.026328636590709173e-21 1.014061154095685070e-20 3.610493744488802428e-21 5.882241825216270609e-20 6.870500382068253202e+02 5.504946113528137373e-20 5.671943325849554691e-20 9.724217183246339603e-21 2.035774913717744667e-27 4.194700863301171076e-21 1.330497252804784533e-24 1.501099208864722073e-23 1.359543276640413861e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.002657355374529223e-21 4.613849691701071299e-21 3.612875474660889679e-21 5.804696136751410705e-20 6.878500381623890689e+02 5.557687626110809053e-20 5.677283224354718381e-20 9.102446077068128250e-21 2.024716309680835566e-27 4.192471739065234166e-21 1.326043936421388817e-24 1.497743820021378974e-23 1.359488829575182013e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.053423928233162487e-21 5.462990849164040341e-21 3.615415955997211471e-21 5.807380056587052557e-20 6.886500381180560453e+02 5.535461075940289339e-20 5.682624310415997505e-20 1.167980886849842237e-20 2.013657705642499428e-27 4.190258146954893069e-21 1.321590898869584446e-24 1.494388431177602704e-23 1.359449916553808312e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.074239871592263749e-21 4.642878684155525046e-21 3.617956437333861273e-21 5.851491122202017524e-20 6.894500380738259082e+02 5.468908685495347219e-20 5.687966580687993971e-20 9.131699899451103422e-21 2.002859947096026731e-27 4.188043854672371614e-21 1.317138142977437442e-24 1.491033042333395322e-23 1.359410040466957274e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.085335970483028155e-21 5.859068355933744269e-21 3.620496918670837579e-21 5.822248330707796798e-20 6.902000289771075359e+02 5.632288331983896478e-20 5.692975971117866199e-20 8.829686682951802237e-21 1.992740254170641724e-27 4.185942430885399267e-21 1.312963993078024046e-24 1.487887403271819736e-23 1.359337505162810437e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.102446886103742923e-21 3.724119960177366811e-21 3.622875251861734758e-21 5.804951008200903422e-20 6.909500379911705750e+02 5.558602812159867293e-20 5.697986517669214106e-20 1.049376379104108790e-20 1.982644656375410996e-27 4.183840956353242337e-21 1.308789994848738953e-24 1.484741688249347517e-23 1.359264968322849761e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.128878356743854230e-21 4.205357487545821781e-21 3.625245403900675700e-21 5.840835575079514215e-20 6.917500379472343184e+02 5.557053134540759043e-20 5.703332174018859156e-20 9.074763647168952359e-21 1.972012398894821747e-27 4.181614799856136922e-21 1.304338064829762128e-24 1.481386299403907335e-23 1.359187713010037070e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.169245400929285914e-21 5.041015017101064966e-21 3.627773535551713962e-21 5.829033228190245644e-20 6.925500379033994705e+02 5.735841747467937408e-20 5.708679001726968622e-20 9.258874739604892426e-21 1.961380141412884740e-27 4.179422492283953850e-21 1.299886427795816462e-24 1.478030910558041624e-23 1.359110713404193822e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.153884799581284498e-21 4.623758973735301286e-21 3.630301667203072711e-21 5.833644476087862003e-20 6.933500378596658038e+02 5.620015687222802196e-20 5.714026997505292771e-20 8.715718680359387152e-21 1.950839873754812416e-27 4.177230184711493173e-21 1.295435086767353239e-24 1.474675521711751854e-23 1.359033714043999552e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.104612016996772718e-21 4.789511554546281849e-21 3.632829798854751947e-21 5.831669498312371344e-20 6.941500378160329774e+02 5.673913812080872241e-20 5.719376158077163933e-20 9.955781787985090434e-21 1.940417855974615821e-27 4.175010471474523835e-21 1.290984044806280308e-24 1.471320132865038906e-23 1.358984120361285945e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.128856894200625027e-21 4.222687346679162949e-21 3.635357930506748661e-21 5.852435963405380818e-20 6.949000287811190901e+02 5.818789774320199406e-20 5.724391990921277176e-20 9.591432731178446332e-21 1.930647331475328480e-27 4.172919150514187389e-21 1.286811517378018946e-24 1.468174493544240661e-23 1.358947991735701557e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.106422738004379646e-21 4.742113873037878314e-21 3.637728025507949471e-21 5.855151480041474348e-20 6.956500377344920025e+02 5.542926618550012795e-20 5.729408962273385736e-20 1.094203552887384728e-20 1.920954193543505696e-27 4.170827779394204734e-21 1.282639158048658117e-24 1.465028778776317335e-23 1.358911862463344190e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.038589274381707120e-21 4.321865579590460029e-21 3.640098177355099387e-21 5.880194037923293034e-20 6.964500376911469175e+02 5.736571832356310335e-20 5.734761453478834613e-20 8.962246120771692567e-21 1.910664285844146853e-27 4.168645351751417254e-21 1.278188993346880940e-24 1.461673389928397742e-23 1.358835706478642729e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.034493664981155568e-21 4.464844994469299673e-21 3.642626309008005651e-21 5.852894782851542020e-20 6.972500376479015358e+02 5.716044399845109507e-20 5.740115096889259053e-20 8.686186657148719034e-21 1.900374378143505184e-27 4.166463533687541420e-21 1.273739139982281498e-24 1.458318001080059673e-23 1.358759076372020312e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.069421154111054130e-21 4.631479875054003757e-21 3.645154440661227136e-21 5.855397587470502750e-20 6.980500376047551754e+02 5.745091604200021990e-20 5.745469889283771131e-20 1.134674994895619081e-20 1.890263635666099160e-27 4.164281715623394753e-21 1.269289601229311160e-24 1.454962612231306360e-23 1.358696802259674093e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.169447808599437811e-21 5.255075609956060804e-21 3.647682284204042269e-21 5.911519754926086635e-20 6.988500375617076088e+02 5.712455766757971416e-20 5.750825827452797762e-20 1.064165388632063151e-20 1.880181444427794238e-27 4.162099897558979508e-21 1.264840380408261351e-24 1.451607223382138980e-23 1.358658449843354124e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.272412210317315493e-21 5.509496120121839627e-21 3.650207058257960133e-21 5.906315453971470146e-20 6.996500375187583813e+02 5.768895705644758551e-20 5.756182908198021716e-20 1.007501213188356228e-20 1.870123172495350142e-27 4.159918079494295687e-21 1.260391480886068950e-24 1.448251834532558707e-23 1.358620097677208506e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.215537351173286917e-21 5.599668348162529808e-21 3.652731832312188704e-21 5.902227000254389573e-20 7.004500374759073793e+02 5.714363056101138566e-20 5.761541128332344306e-20 1.009529335729855735e-20 1.860232263934235446e-27 4.157744183993966057e-21 1.255942906077131051e-24 1.444896445682566717e-23 1.358552835582687653e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.144007887710595260e-21 0.000000000000000000e+00 3.655256606366727230e-21 5.880936106483353371e-20 7.012500374331541479e+02 5.721721634255557993e-20 5.766900484679828815e-20 9.647729944111595114e-21 1.850341355371912180e-27 4.155572755538581613e-21 1.251494659444142321e-24 1.441541056832164774e-23 1.358476571256271898e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.075533277649810923e-21 0.000000000000000000e+00 3.657781380421574205e-21 5.878430461440937845e-20 7.020500373904983462e+02 5.658277417720953313e-20 5.772260974075664378e-20 9.406899131539611876e-21 1.840521537526988280e-27 4.153402742594388603e-21 1.247046744498945399e-24 1.438185667981353758e-23 1.358405571843469303e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.074322628133769289e-21 0.000000000000000000e+00 3.660306154476728877e-21 5.879784273676610907e-20 7.028500373479395193e+02 5.743860792787094205e-20 5.777622593366116637e-20 9.090875629101881367e-21 1.830820180577023086e-27 4.151241605268599216e-21 1.242599164803403879e-24 1.434830279130136316e-23 1.358367583489998999e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.142096769930181725e-21 0.000000000000000000e+00 3.662830928532189743e-21 5.880322600503356276e-20 7.036500373054776674e+02 5.536154786722100773e-20 5.782985339408490426e-20 9.455306051597860153e-21 1.821118823625881966e-27 4.149080467942548022e-21 1.238151923970285591e-24 1.431474890278512152e-23 1.358329595386866111e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.158085706067637233e-21 0.000000000000000000e+00 3.665355702587956048e-21 5.891389527875566935e-20 7.044000283929580064e+02 5.718662533699013618e-20 5.788013874861576051e-20 1.110479858153145001e-20 1.812095587914113441e-27 4.147054425668312196e-21 1.233982996022145387e-24 1.428329250444363769e-23 1.358277393294623067e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.152753908773267137e-21 0.000000000000000000e+00 3.667722650263245678e-21 5.924995135312889097e-20 7.051500372261211851e+02 5.846608403290981440e-20 5.793043514291907908e-20 1.172220198263069354e-20 1.803122631557174451e-27 4.145028335455502098e-21 1.229814273546522963e-24 1.425183536180628484e-23 1.358206234305758711e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.173338885474723102e-21 0.000000000000000000e+00 3.670089653943337520e-21 5.941855336384872508e-20 7.059500371839355921e+02 5.717674566723697748e-20 5.798409482339478683e-20 9.496730281939761328e-21 1.793551591337892476e-27 4.142867198128704607e-21 1.225368027540106983e-24 1.421828147327845283e-23 1.358130332520927642e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.242286145105267297e-21 0.000000000000000000e+00 3.672614427999976513e-21 5.907509756836748704e-20 7.067500371418456098e+02 5.864671816019601364e-20 5.803776565064377275e-20 9.884169963154569360e-21 1.784116321092945864e-27 4.140713579382773372e-21 1.220922134893491939e-24 1.418472758474661533e-23 1.358082526518726547e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.285784601310227734e-21 0.000000000000000000e+00 3.675144894257099541e-21 5.919291054348834787e-20 7.075500370998506696e+02 5.881328885768083153e-20 5.809144759377036496e-20 9.094916355196084920e-21 1.774732537801751258e-27 4.138562636099458239e-21 1.216476599480990214e-24 1.415117369621078995e-23 1.358044720670964459e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.308511553998661184e-21 0.000000000000000000e+00 3.677676382143033658e-21 5.911988247710152226e-20 7.083500370579506580e+02 5.858810531134189826e-20 5.814514062198675570e-20 1.049611915773090490e-20 1.765348754509443505e-27 4.136415865011960970e-21 1.212031425233439305e-24 1.411761980767098259e-23 1.358003648363175560e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.353316392062228655e-21 0.000000000000000000e+00 3.680207870029268701e-21 5.940591076841745700e-20 7.091500370161452338e+02 5.817760556508735429e-20 5.819884470461230318e-20 1.036671277888483878e-20 1.756141278433200042e-27 4.134312578736894895e-21 1.207586616139234790e-24 1.408406591912720794e-23 1.357928467602291879e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.381467823510306525e-21 0.000000000000000000e+00 3.682739357915802414e-21 5.943689869942104761e-20 7.100000469483552479e+02 5.972178893085060243e-20 5.825591804049662168e-20 1.001836968400624952e-20 1.746368070064650971e-27 4.132077810840004568e-21 1.202864355681565640e-24 1.404841449410608230e-23 1.357848587318487707e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.280273426680976346e-21 0.000000000000000000e+00 3.685429095364888252e-21 5.942911551596254179e-20 7.108500369276208630e+02 5.785403887644157432e-20 5.831300244483868457e-20 8.937182224381587609e-21 1.736632227116477489e-27 4.129822436390873499e-21 1.198142627790249809e-24 1.401276390595859363e-23 1.357768709128434952e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.164270472783833636e-21 0.000000000000000000e+00 3.688118769675674816e-21 5.930821978443518781e-20 7.116500368861088646e+02 5.929341405299491766e-20 5.836674087592053359e-20 9.495765874090514201e-21 1.727563169291106619e-27 4.127681591431539328e-21 1.193698986158336889e-24 1.397921001740251155e-23 1.357693528972816886e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.149902737280718133e-21 0.000000000000000000e+00 3.690650257563137640e-21 5.944720577956465368e-20 7.124500368446899756e+02 6.050028995232289710e-20 5.842049023597852670e-20 1.000885617524834174e-20 1.718494111464680717e-27 4.125540746471956140e-21 1.189255726763370456e-24 1.394565612884252683e-23 1.357618349010950005e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.131367647986033955e-21 0.000000000000000000e+00 3.693181745450894620e-21 5.958335850497782222e-20 7.132500368033639688e+02 5.990336718729295816e-20 5.847425049677790500e-20 1.095359083629759896e-20 1.709509590562575901e-27 4.123441959766897593e-21 1.185453988176127714e-24 1.391565806957760262e-23 1.357576659832638629e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.116658215644788514e-21 0.000000000000000000e+00 3.695713233338945755e-21 5.980136825113301111e-20 7.140500367621306168e+02 5.774404750374675381e-20 5.852802162678694622e-20 1.073101587307248469e-20 1.700609591021297189e-27 4.121348501930873148e-21 1.181794265631948968e-24 1.388644735447381517e-23 1.357539214179510207e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.122529915526040797e-21 0.000000000000000000e+00 3.698244721227290294e-21 5.981383439386433022e-20 7.148500367209894648e+02 5.878461317176723474e-20 5.858180359565384906e-20 9.211098301230421149e-21 1.691709591478992860e-27 4.119247098453439184e-21 1.178134563785880261e-24 1.385723663936665993e-23 1.357493823139354134e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.145840703988751434e-21 0.000000000000000000e+00 3.700757268823083942e-21 5.961361808071477228e-20 7.156500366799403992e+02 5.843892631109199528e-20 5.863559637355365036e-20 1.019646170479665933e-20 1.682926888506962262e-27 4.117116257441280492e-21 1.174474882831414760e-24 1.382802592425613983e-23 1.357418994970613213e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.175341569528589317e-21 0.000000000000000000e+00 3.703263252545689795e-21 5.982759136251722256e-20 7.164500366389829651e+02 5.838882665909012483e-20 5.868939993076472515e-20 9.992947034989883173e-21 1.674194444509590584e-27 4.114985416428877297e-21 1.170815222964463475e-24 1.379881520914227546e-23 1.357344166995802528e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.250577560905452077e-21 0.000000000000000000e+00 3.705769236268583032e-21 5.984879413664653934e-20 7.172500365981169352e+02 5.919812478044548273e-20 5.874321423766837736e-20 9.253889124926072250e-21 1.665462000511221630e-27 4.112879904674671917e-21 1.167155584383394567e-24 1.376960449402507562e-23 1.357289527707244389e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.305065691245690963e-21 0.000000000000000000e+00 3.708275219991762150e-21 5.978480177096648655e-20 7.180500365573419685e+02 5.892892789003273823e-20 5.879703926474850283e-20 9.246314390021626854e-21 1.656843162361033523e-27 4.110796183850643941e-21 1.163495967289069533e-24 1.374039377890454913e-23 1.357252256910196328e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.369342855855065093e-21 0.000000000000000000e+00 3.710781203715226395e-21 5.983904083385806438e-20 7.188500365166576103e+02 5.720154719651640624e-20 5.885087498259104759e-20 8.852900417517608739e-21 1.648238718354171762e-27 4.108712463026379737e-21 1.159836371884884894e-24 1.371118306378071362e-23 1.357214986310540476e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.458415945248874932e-21 0.000000000000000000e+00 3.713287187438975016e-21 5.983607091612846611e-20 7.197000463155929992e+02 6.058046398116908171e-20 5.890808777643863186e-20 1.013565957088568385e-20 1.639119157449674272e-27 4.106473488889407401e-21 1.155948030742279551e-24 1.368014631959086316e-23 1.357141745049264030e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.412323294656724903e-21 0.000000000000000000e+00 3.715949825975832685e-21 6.009348661805476080e-20 7.205500364305036101e+02 5.940268053861910812e-20 5.896531124598527527e-20 1.110603816558541438e-20 1.630152890042829463e-27 4.104230459419504151e-21 1.152059804612734476e-24 1.364911029413160169e-23 1.357062977836526252e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.282129289554704268e-21 0.000000000000000000e+00 3.718612402852880103e-21 6.031562584922378187e-20 7.213500363901009678e+02 5.950916995134035521e-20 5.901918018399519239e-20 9.888929891318098489e-21 1.621713952415926484e-27 4.102132164154577824e-21 1.148400278329768269e-24 1.361989957899748061e-23 1.356988937218650435e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.148524842296979871e-21 0.000000000000000000e+00 3.721118386577511192e-21 6.015136356824842224e-20 7.221500363497879107e+02 5.927763025229771745e-20 5.907305969250514453e-20 9.000603997032794255e-21 1.613331253327307807e-27 4.100067648129579774e-21 1.144740774603611666e-24 1.359068886386008871e-23 1.356915144260279265e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.145976313738526571e-21 0.000000000000000000e+00 3.723624370302422142e-21 6.006463024094242788e-20 7.229500363095640978e+02 5.859166299343674724e-20 5.912694974261799732e-20 9.690587419657743604e-21 1.605042266959935131e-27 4.098003132104350762e-21 1.141081293651292334e-24 1.356147814871943776e-23 1.356841351496176686e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.140745699274055856e-21 0.000000000000000000e+00 3.726129117167110306e-21 6.022462398463348697e-20 7.237500362694291880e+02 5.966014766844973884e-20 5.918085030553623513e-20 1.050653816708138127e-20 1.596753280591641230e-27 4.095938616078892294e-21 1.137421835692629918e-24 1.353226743357553951e-23 1.356788297786831768e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.143283305117410963e-21 0.000000000000000000e+00 3.728632717083786665e-21 6.041419141605075073e-20 7.246000460023907408e+02 5.959811293058109806e-20 5.923813179928408149e-20 9.779635483906338338e-21 1.588052165098564110e-27 4.093745042574475372e-21 1.133533642338987915e-24 1.350123069179461786e-23 1.356749063189973948e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.099727487038004392e-21 0.000000000000000000e+00 3.731292822588010597e-21 6.034673670528799875e-20 7.254500361844363852e+02 5.776631989933009693e-20 5.929542377664313991e-20 9.597273764066345508e-21 1.579432966410451892e-27 4.091551519524034902e-21 1.129645564896821451e-24 1.347019466388402749e-23 1.356709829718599682e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.106039995825937881e-21 0.000000000000000000e+00 3.733952866907642978e-21 6.037395457605588930e-20 7.262500361445773933e+02 6.072036398451487512e-20 5.934935700755904982e-20 1.047251561512969208e-20 1.571320686112881567e-27 4.089487003497864743e-21 1.125986180241644206e-24 1.344098394873005525e-23 1.356636957745977858e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.132278807098626838e-21 0.000000000000000000e+00 3.736456466825182245e-21 6.057303055052068389e-20 7.270500361048062814e+02 5.881996474875994470e-20 5.940330063353475370e-20 1.065645589564408371e-20 1.563288234809747235e-27 4.087422487471467384e-21 1.122326819517372157e-24 1.341177323357287391e-23 1.356563165982313883e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.210283975191915082e-21 0.000000000000000000e+00 3.738960066742996859e-21 6.066073543401262618e-20 7.279000457938348063e+02 5.829746691303372441e-20 5.946062775075475104e-20 1.167595799389076608e-20 1.554773225468777241e-27 4.085235042718961220e-21 1.118438730719787001e-24 1.338073649339609650e-23 1.356484980427419946e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.246123201378027888e-21 0.000000000000000000e+00 3.741620172109732715e-21 6.090540547183341899e-20 7.287500360205823426e+02 5.790120583923554249e-20 5.951796522453387868e-20 1.039214633847900065e-20 1.546272484828518690e-27 4.083061551728191053e-21 1.114550758512540985e-24 1.334970046385328815e-23 1.356407298664250884e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.246951405437514635e-21 0.000000000000000000e+00 3.744280216569259080e-21 6.072861538681393920e-20 7.295500359810833970e+02 5.856779708920078111e-20 5.957194115315553959e-20 1.134584221828844069e-20 1.538419210107093712e-27 4.081015889728736755e-21 1.110891474100179166e-24 1.332048974868617094e-23 1.356334186716253496e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.207815448113626369e-21 0.000000000000000000e+00 3.746783816487925316e-21 6.095040326532345493e-20 7.303500359416709671e+02 5.905376407499651196e-20 5.962592736075172354e-20 1.015509959095154413e-20 1.530565935384819614e-27 4.078970227729060524e-21 1.107232214607581820e-24 1.329127903351589459e-23 1.356284820708816787e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.172795460189488301e-21 0.000000000000000000e+00 3.749287416406862387e-21 6.079171935462988390e-20 7.312000455871612985e+02 5.919005724580227228e-20 5.968329959174515189e-20 1.111935525510691006e-20 1.522263560777611272e-27 4.076796687083057989e-21 1.103344234668870318e-24 1.326024229492884399e-23 1.356245951701135383e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.135283904308218223e-21 0.000000000000000000e+00 3.751950393864878374e-21 6.101502054345319585e-20 7.320500358582056606e+02 5.836644539181680007e-20 5.974068205407148260e-20 1.016538039696552853e-20 1.514074089296592538e-27 4.074624910354486050e-21 1.099456372063196225e-24 1.322920626376860684e-23 1.356205724736299734e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.125473497532520457e-21 0.000000000000000000e+00 3.754618853693502795e-21 6.090435854332994713e-20 7.328500358190617590e+02 6.031415733730395029e-20 5.979470020410722293e-20 1.057142925147802005e-20 1.506366263586778783e-27 4.072624910452345734e-21 1.095797192057742327e-24 1.319999554858852539e-23 1.356132945526391599e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.129090846755908342e-21 0.000000000000000000e+00 3.757130373920461051e-21 6.102651793332368192e-20 7.336500357800032361e+02 6.013019481197138016e-20 5.984872851866507898e-20 9.786580018219796824e-21 1.498711312419447567e-27 4.070624910549992513e-21 1.092138038016119636e-24 1.317078483340532595e-23 1.356060166473741287e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.154420336661542613e-21 0.000000000000000000e+00 3.759641894147687132e-21 6.094942943878123285e-20 7.345000453823449789e+02 5.889381705539841882e-20 5.990614536090514075e-20 9.519792131183613876e-21 1.490639916891124329e-27 4.068487157208576435e-21 1.088250171479042707e-24 1.313974809639377721e-23 1.355982838025311487e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.174182392535774669e-21 0.000000000000000000e+00 3.762310414664994200e-21 6.096430262045004190e-20 7.353500356972862164e+02 5.973844213528012291e-20 5.996357231104727695e-20 9.523664788059088644e-21 1.482568704509247706e-27 4.066323545497816652e-21 1.084362423085716845e-24 1.310871206363071677e-23 1.355905511509121497e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.258392833128937085e-21 0.000000000000000000e+00 3.764978874631428689e-21 6.102441510870585595e-20 7.361500356584926976e+02 6.077563875145119288e-20 6.001763221289889837e-20 9.613575797883221502e-21 1.475099669236740543e-27 4.064287181960200499e-21 1.080703351884996270e-24 1.307950134843784155e-23 1.355832732948066119e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.377311776505836948e-21 0.000000000000000000e+00 3.767490394859486832e-21 6.109614960176274530e-20 7.370000452284020867e+02 6.102397600922472943e-20 6.007508252130230688e-20 1.182774100123138796e-20 1.467215097708960143e-27 4.062130202136175688e-21 1.076815574439118693e-24 1.304846461261050785e-23 1.355781889860055780e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.377444068361150048e-21 0.000000000000000000e+00 3.770158915274976152e-21 6.153955275602876257e-20 7.378500355763358129e+02 6.092659961264733435e-20 6.013254284527677033e-20 9.926953940421894502e-21 1.459330704481574668e-27 4.059976380440053924e-21 1.072927915799211518e-24 1.301742857864278023e-23 1.355743374381158370e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.266338644068785825e-21 0.000000000000000000e+00 3.772827375344987304e-21 6.125487131436640500e-20 7.386500355378045697e+02 6.283743088387989533e-20 6.018663406869034803e-20 1.050776591729819664e-20 1.452001743610789372e-27 4.057950362406340493e-21 1.069268930106715740e-24 1.298821786344032767e-23 1.355706225861264616e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.299583644348470705e-21 0.000000000000000000e+00 3.775338895573868481e-21 6.140594762852123124e-20 7.395000450755001111e+02 5.972673063889376561e-20 6.024411756191955608e-20 1.033268604137993250e-20 1.444219759739818161e-27 4.055844482921058465e-21 1.065381244624927893e-24 1.295718112878923182e-23 1.355629594622236957e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.348192239978311725e-21 0.000000000000000000e+00 3.778005866728489440e-21 6.143446273762049305e-20 7.403500354562023631e+02 5.992387708930463032e-20 6.030161097938935629e-20 1.089668175839270036e-20 1.436459680894179115e-27 4.053738650896796067e-21 1.061493678655087376e-24 1.292614509362501258e-23 1.355552965288092816e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.353370992662384645e-21 0.000000000000000000e+00 3.780663172850968630e-21 6.158834482442623740e-20 7.412000449721159612e+02 5.982761732291060385e-20 6.035911687912466746e-20 9.807812608553079869e-21 1.428809595250956356e-27 4.051617003673941958e-21 1.057606057413434340e-24 1.289510835976925034e-23 1.355476334406698875e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.285249474191561783e-21 0.000000000000000000e+00 3.783320538795434907e-21 6.145897120755308646e-20 7.420500353749739588e+02 6.198458805480581302e-20 6.041663264156100628e-20 9.251263129530878354e-21 1.421159681625234261e-27 4.049472883738804686e-21 1.053718556189937460e-24 1.286407232379605001e-23 1.355399705426280167e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.234973054258088865e-21 0.000000000000000000e+00 3.785977844987178362e-21 6.142735227588304907e-20 7.428500353368774540e+02 6.138835743142329457e-20 6.047077589475673972e-20 1.069914043378910692e-20 1.414022594897574278e-27 4.047454865816886012e-21 1.050059720478351726e-24 1.283486160857772386e-23 1.355327583384581903e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.243907923472499579e-21 0.000000000000000000e+00 3.788478867169326210e-21 6.171541953043221273e-20 7.437000448209390697e+02 6.068333684656567114e-20 6.052831451337116713e-20 1.048805047784432700e-20 1.406539605422502238e-27 4.045346077795890578e-21 1.046172196312357647e-24 1.280382487588498545e-23 1.355279460530761985e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.242765011759431190e-21 0.000000000000000000e+00 3.791136233014215138e-21 6.173556950274548165e-20 7.445500352561942918e+02 6.129294920125554478e-20 6.058586290500899248e-20 9.411035876268121001e-21 1.399056783642050386e-27 4.043249688830013801e-21 1.042284792949186446e-24 1.277278883872885283e-23 1.355241291406330822e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.223663516034678994e-21 0.000000000000000000e+00 3.793793539307241443e-21 6.161766500197028177e-20 7.454000447187180498e+02 5.994971197335641392e-20 6.064342361610616410e-20 1.012963548581414005e-20 1.391646279104443776e-27 4.041154354485290390e-21 1.038397336627463939e-24 1.274175210682253336e-23 1.355198675379486571e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.208327188437573072e-21 0.000000000000000000e+00 3.796450905084796551e-21 6.178747240987385927e-20 7.462500351758785655e+02 6.170917772446514783e-20 6.070099403979923721e-20 1.091014998349498658e-20 1.384279695142386029e-27 4.039067324344941249e-21 1.034510001670639608e-24 1.271071606886656499e-23 1.355122730985351131e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.221549872756896940e-21 0.000000000000000000e+00 3.799108211446304712e-21 6.197710175718660896e-20 7.471000446169621227e+02 6.070044366214524866e-20 6.075857671954211039e-20 1.063998606653998891e-20 1.376912946652995256e-27 4.036980247592280153e-21 1.031261037247867136e-24 1.268349094356678136e-23 1.355046785073151442e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.228698369105084018e-21 0.000000000000000000e+00 3.801765577156831438e-21 6.198683722895036645e-20 7.479500350959281150e+02 5.902993801290637478e-20 6.081616905197328136e-20 1.093591715577385582e-20 1.369649232628766275e-27 4.034874912260179742e-21 1.028046612830062929e-24 1.265647217094051669e-23 1.354970841033287995e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.329896166843466546e-21 0.000000000000000000e+00 3.804422883586509996e-21 6.209846273944611806e-20 7.488000445156681053e+02 6.262640758980243613e-20 6.087377357412237235e-20 9.748200774212028599e-21 1.362400641662132079e-27 4.032749888710829176e-21 1.024832122424703804e-24 1.262945279624107864e-23 1.354894895479283440e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.313895757904095295e-21 0.000000000000000000e+00 3.807079009132018963e-21 6.195636096515143653e-20 7.496500350163402118e+02 6.242500173868060104e-20 6.093138768932429131e-20 9.376211880849315446e-21 1.355166004629116231e-27 4.030624912459149289e-21 1.021617709260036323e-24 1.260243402292483847e-23 1.354818953827412504e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.315082500358299705e-21 0.000000000000000000e+00 3.809735072316830395e-21 6.195565087006721538e-20 7.505000444148333827e+02 6.160259239376187485e-20 6.098901393006430841e-20 8.603162089066572450e-21 1.348047628049394959e-27 4.028539891430406636e-21 1.018403230377670140e-24 1.257541464890077629e-23 1.354775301966165978e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.310062944782958718e-21 0.000000000000000000e+00 3.812391194553839229e-21 6.189999712823389167e-20 7.513500349371123548e+02 6.211882156828017074e-20 6.104664970474878665e-20 1.018646713942116322e-20 1.340929409547926795e-27 4.026462136820391717e-21 1.015188828682202408e-24 1.254839587489771681e-23 1.354737478850679073e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.281344756691690645e-21 0.000000000000000000e+00 3.815047257806168047e-21 6.219537395903084614e-20 7.522000443144540895e+02 6.182969506664912134e-20 6.110429754124217265e-20 9.609559291708992617e-21 1.333850821409750806e-27 4.024386175340929689e-21 1.011974361540891635e-24 1.252137650154599773e-23 1.354692164434248631e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.284886190608883889e-21 0.000000000000000000e+00 3.817703379977082125e-21 6.216032017733391331e-20 7.530500348582422703e+02 6.202266500624617506e-20 6.116195485300396402e-20 1.021469481041557202e-20 1.326849204388038007e-27 4.022317614283038072e-21 1.008759971536187624e-24 1.249435772685922077e-23 1.354616898756116098e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.311550986772758228e-21 0.000000000000000000e+00 3.820359443296623641e-21 6.231434272148268085e-20 7.539000442145276111e+02 6.157022349091866838e-20 6.121962416329222833e-20 9.413347818460705742e-21 1.319847432402365517e-27 4.020249007442520605e-21 1.005545516359589898e-24 1.246733835417682523e-23 1.354541631552225939e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.308318928677678304e-21 0.000000000000000000e+00 3.823015565401740881e-21 6.224463531658747357e-20 7.547500347797276845e+02 6.084840808516833461e-20 6.127730289060139778e-20 1.019610490258750789e-20 1.312919212498066347e-27 4.018180446332520545e-21 1.002331138272894889e-24 1.244031957880942529e-23 1.354466366152348153e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.355261760622335267e-21 0.000000000000000000e+00 3.825671628788189654e-21 6.242621192340591606e-20 7.556000441150507640e+02 6.096524185012963858e-20 6.133499355359773776e-20 1.022515637261222328e-20 1.306047407069884814e-27 4.016111839543017652e-21 9.991166952904452175e-25 1.241330020679335873e-23 1.354391099230517582e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.403507080602943622e-21 0.000000000000000000e+00 3.828327750827804211e-21 6.248945416119559500e-20 7.564500347015658690e+02 6.226915643941219784e-20 6.139269357579237889e-20 9.810200393953858905e-21 1.299175753214344908e-27 4.014043278381144625e-21 9.959023293548696601e-25 1.238628143074841560e-23 1.354315834108996482e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.405116165227722386e-21 0.000000000000000000e+00 3.830983814280858564e-21 6.247968266760978153e-20 7.573000440160205926e+02 6.174433147771319860e-20 6.145040547127431314e-20 1.101442824563913465e-20 1.292415113755534271e-27 4.012015754323122838e-21 9.926878988019661127e-25 1.235926205939569519e-23 1.354273901288445003e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.368801310525778350e-21 0.000000000000000000e+00 3.833647203966119039e-21 6.273522546899004617e-20 7.581500346237544363e+02 6.244917264427555571e-20 6.150812666855324174e-20 1.026810847269621543e-20 1.285686616675825979e-27 4.009993750234240481e-21 9.894735452566755357e-25 1.233224328267626957e-23 1.354236412141637029e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.368095606179022110e-21 0.000000000000000000e+00 3.836312376215811286e-21 6.266516597384808808e-20 7.590000439174341409e+02 6.226200024361974992e-20 6.156585967715536379e-20 9.135790328290957459e-21 1.278957971678798395e-27 4.007965683532505736e-21 9.862591273748732021e-25 1.230522391198392719e-23 1.354191060477149702e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.390714343483284720e-21 0.000000000000000000e+00 3.838977607055874219e-21 6.254733232991784983e-20 7.599000438654196614e+02 5.999958161233208154e-20 6.162699953104817798e-20 9.673747050363723636e-21 1.271951123055729615e-27 4.005794631026400562e-21 9.828556704626022159e-25 1.227661548099555680e-23 1.354112066364878544e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.397379118849830631e-21 0.000000000000000000e+00 3.841799585162774521e-21 6.268855928861196364e-20 7.607500345054214677e+02 6.138714014394174666e-20 6.168475288396409853e-20 1.021009492628680035e-20 1.265336133137724009e-27 4.003744215008852273e-21 9.796413363440578653e-25 1.224959670325042419e-23 1.354037461776036401e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.339461238868243397e-21 0.000000000000000000e+00 3.844464757513644293e-21 6.282810916396309864e-20 7.616000437675057810e+02 6.343232573591212746e-20 6.174251795426912117e-20 9.830971690023403603e-21 1.258743262836524594e-27 4.001693754069613207e-21 9.764269383233579410e-25 1.222257733356240949e-23 1.353962855693024516e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.273803240352207407e-21 0.000000000000000000e+00 3.847129988254638443e-21 6.282200280702944782e-20 7.624500344284863331e+02 6.216700952732990208e-20 6.180029218303631780e-20 1.177419235321969090e-20 1.252227853251100265e-27 3.999643338001458853e-21 9.732126172284304990e-25 1.219555855515042188e-23 1.353888251382979352e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.226140390055820764e-21 0.000000000000000000e+00 3.849795160671287751e-21 6.321008347725768908e-20 7.633000436700280034e+02 6.196810561936608797e-20 6.185807806831456078e-20 1.002755581349451211e-20 1.245712301240621898e-27 3.997592877111774867e-21 9.699982325187009343e-25 1.216853918611540017e-23 1.353813645582461518e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.261528029584989483e-21 0.000000000000000000e+00 3.852460391347870076e-21 6.296620813743108064e-20 7.642000436185977605e+02 6.179889529342199128e-20 6.191927375084012370e-20 9.472842979372005465e-21 1.238873005466873426e-27 3.995430462924765748e-21 9.665948108746593045e-25 1.213993075510845844e-23 1.353770775931828256e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.333934719853015578e-21 0.000000000000000000e+00 3.855282369456602269e-21 6.294313288658386999e-20 7.650500343114822499e+02 6.105422500222717449e-20 6.197707968170194189e-20 1.078784793136427052e-20 1.232483908758691855e-27 3.993389000561942413e-21 9.633805102077050349e-25 1.211291197568233511e-23 1.353733614958151516e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.397279106595195189e-21 0.000000000000000000e+00 3.857947541973287839e-21 6.321350071997773106e-20 7.659000435217814129e+02 6.248225265052415942e-20 6.203489717678430368e-20 9.221816780256050530e-21 1.226094672861276723e-27 3.991359897818426749e-21 9.601661463708640708e-25 1.208589260764042393e-23 1.353686495149651308e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.357636400506189133e-21 0.000000000000000000e+00 3.860606790426286840e-21 6.302060515896268246e-20 7.668000434706995065e+02 6.059945195646484429e-20 6.209612623410488196e-20 1.245713091908138920e-20 1.219408143660394008e-27 3.989246854460097211e-21 9.567627469281118609e-25 1.205728417662240904e-23 1.353608188742696995e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.365681042619285113e-21 0.000000000000000000e+00 3.863418172466509594e-21 6.363472277519345507e-20 7.676500341952705639e+02 6.152623849534858977e-20 6.215396359676166421e-20 1.068315493694493104e-20 1.213130203868956157e-27 3.987251224063277591e-21 9.535484673277812526e-25 1.203026539618906044e-23 1.353534233639149690e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.357719604879342733e-21 0.000000000000000000e+00 3.866073337792115694e-21 6.336782091775551532e-20 7.685000433745379951e+02 6.328069206236949618e-20 6.221181243232571621e-20 9.985042813376031404e-21 1.206852127773121976e-27 3.985237991965385474e-21 9.503341250094401414e-25 1.200324602913355947e-23 1.353460476596468417e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.409095480305325061e-21 0.000000000000000000e+00 3.868728560765727436e-21 6.331268127243788867e-20 7.694000433238009009e+02 6.326138446086732562e-20 6.227307458030695126e-20 9.194826850231020342e-21 1.200320347507028193e-27 3.983095134943331076e-21 9.469307484619177680e-25 1.197463759810458456e-23 1.353382509434667065e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.428683921121174506e-21 0.000000000000000000e+00 3.871539942807027508e-21 6.325397079209447308e-20 7.702500340798435445e+02 6.119115367101248285e-20 6.233094310737877393e-20 1.069549928046260931e-20 1.194166695421958945e-27 3.981071347428943451e-21 9.437164905935211545e-25 1.194761881667084472e-23 1.353308874723236914e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.414794137273751334e-21 0.000000000000000000e+00 3.874195108230943304e-21 6.354574186832380291e-20 7.711000432282875181e+02 6.187123953147299310e-20 6.238882301700947137e-20 1.040133446242495779e-20 1.188019856617847590e-27 3.979083015829976994e-21 9.405021704664208231e-25 1.192059945059513151e-23 1.353235238559092476e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.385967110734292835e-21 0.000000000000000000e+00 3.876850331108269833e-21 6.355265764571345659e-20 7.720000431778918255e+02 6.170989320749204150e-20 6.245011797458217026e-20 1.037145598503552852e-20 1.181593410696706315e-27 3.976979119843889507e-21 9.370988175372850642e-25 1.189199101955530532e-23 1.353157275420016546e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.373271120267282534e-21 0.000000000000000000e+00 3.879661713150635937e-21 6.360751578969928874e-20 7.729000431276134577e+02 6.459390815927410872e-20 6.251142422438791841e-20 1.012445951630192006e-20 1.175166964774727220e-27 3.974878347892623862e-21 9.336954729577901880e-25 1.186338258851174988e-23 1.353092792941079111e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.356916696062713586e-21 0.000000000000000000e+00 3.882473095193368419e-21 6.362736952211838700e-20 7.737500339256858979e+02 6.140525773336660918e-20 6.256933428639757799e-20 9.456018864769032117e-21 1.169136058397659710e-27 3.972899921035041690e-21 9.304812454442055015e-25 1.183636380574200193e-23 1.353056117601007024e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.398590384466238867e-21 0.000000000000000000e+00 3.885128260748574709e-21 6.358301800680744760e-20 7.746000430329621622e+02 6.212523280959639934e-20 6.262725561084538021e-20 1.211919912042510378e-20 1.163175500707129696e-27 3.970921451561208446e-21 9.272669563028267722e-25 1.180934444097489312e-23 1.353019441586346001e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.420043972166395783e-21 0.000000000000000000e+00 3.887783519605530130e-21 6.409070623181985824e-20 7.755000429830206485e+02 6.201280027667881968e-20 6.268859429665203770e-20 1.073110250744309768e-20 1.156864389946225733e-27 3.968826624091244772e-21 9.238636363640881916e-25 1.178073600992063039e-23 1.352955175929465740e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.421483098950350861e-21 0.000000000000000000e+00 3.890594998264155000e-21 6.390304325987881035e-20 7.764000429331947544e+02 6.203620826284220070e-20 6.274994414630949510e-20 1.240513167057400055e-20 1.150627901819531215e-27 3.966731796621011770e-21 9.204603251390339310e-25 1.175212757886269130e-23 1.352877550245685419e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.409511480769422249e-21 0.000000000000000000e+00 3.893406476923141734e-21 6.426486224580100388e-20 7.773000428834844797e+02 6.285413288092133015e-20 6.281130512710549525e-20 1.031564793256380836e-20 1.144445934947869203e-27 3.964638362576573945e-21 9.170570227246808452e-25 1.172351914780107733e-23 1.352799976297220046e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.413303885842818842e-21 0.000000000000000000e+00 3.896217955582488828e-21 6.395487282018129115e-20 7.781500337338552526e+02 6.135265621650957652e-20 6.286926673509324833e-20 1.113559466463119519e-20 1.138607473205158520e-27 3.962676845229565034e-21 9.138428352670491701e-25 1.169650036336891441e-23 1.352727290453375065e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.397995283648627893e-21 0.000000000000000000e+00 3.898873212547435498e-21 6.414850410256245988e-20 7.790000427899005899e+02 6.342287666598933571e-20 6.292723945691471455e-20 1.051866614587483615e-20 1.132843465877243509e-27 3.960715285869460419e-21 9.106285869971638004e-25 1.166948100023029139e-23 1.352654603166209595e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.301566274499661812e-21 0.000000000000000000e+00 3.901528526384457718e-21 6.409770676374921561e-20 7.799000427405211440e+02 6.166119191820459343e-20 6.298863241169137023e-20 1.018818398907765607e-20 1.126760200904885607e-27 3.958624258515869570e-21 9.072253105942830548e-25 1.164087256915816115e-23 1.352577641104206762e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.325573623933665232e-21 0.000000000000000000e+00 3.904340005044838494e-21 6.410553313306193909e-20 7.808000426912556122e+02 6.216821434187200201e-20 6.305003637154484823e-20 1.066479670399240560e-20 1.120680369382187004e-27 3.956508874016279941e-21 9.038220433933893701e-25 1.161226413808241038e-23 1.352500679169496614e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.353586893814429321e-21 0.000000000000000000e+00 3.907151483705575869e-21 6.424432687321792985e-20 7.817000426421037673e+02 6.305708789621926885e-20 6.311145130452487356e-20 9.533410950748888208e-21 1.114699961545530879e-27 3.954393489516422487e-21 9.004941860859312216e-25 1.158412628878373919e-23 1.352423717362100403e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.317258789726413936e-21 0.000000000000000000e+00 3.909962962366667585e-21 6.412538593699849266e-20 7.826000425930648134e+02 6.336123643601146980e-20 6.317287717962970376e-20 1.077086453105634558e-20 1.108719553708124465e-27 3.952337083015707842e-21 8.976843305860236214e-25 1.155922089731941727e-23 1.352376244556719308e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.329365480766075470e-21 0.000000000000000000e+00 3.912774441028112137e-21 6.438174978683278685e-20 7.834500335056474114e+02 6.152740182810914518e-20 6.323089990623232924e-20 1.134427151509682522e-20 1.103096366353329227e-27 3.950411889923106083e-21 8.950307146701099224e-25 1.153569938890557505e-23 1.352339883661361052e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.343604544995633795e-21 0.000000000000000000e+00 3.915432157307844807e-21 6.453756271766422631e-20 7.843000425007426202e+02 6.481924369831087913e-20 6.328893357113867848e-20 9.089524006561512670e-21 1.097540209995145821e-27 3.948485495972877144e-21 8.923771484415465863e-25 1.151217738010053554e-23 1.352301419795347750e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.339028397452459225e-21 0.000000000000000000e+00 3.918097341281172163e-21 6.423667558354932008e-20 7.852000424520281285e+02 6.413483411942476783e-20 6.335039087472054081e-20 1.034686374543526855e-20 1.091657283484303832e-27 3.946426174050443810e-21 8.895676367103831499e-25 1.148727198862723285e-23 1.352225110373811603e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.323706723941976717e-21 0.000000000000000000e+00 3.920919270766627382e-21 6.448647733640244039e-20 7.861000424034251637e+02 6.285863895149323013e-20 6.341185899591099821e-20 1.111054287379786982e-20 1.085833089079304400e-27 3.944366852127756194e-21 8.867582461776008496e-25 1.146236659715084595e-23 1.352148801079723305e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.350279006463464684e-21 0.000000000000000000e+00 3.923741200252431676e-21 6.467467857747105771e-20 7.870000423549332709e+02 6.210100489936977556e-20 6.347333790328243694e-20 1.211745673297515064e-20 1.080076004369252499e-27 3.942307530204813542e-21 8.839489779987925496e-25 1.143746120567138366e-23 1.352072491913104674e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.349438762487978387e-21 0.000000000000000000e+00 3.926563129738585045e-21 6.491536923605443044e-20 7.879000423065522227e+02 6.356433700556166734e-20 6.353482756552343705e-20 1.122844390000156907e-20 1.074318919658491563e-27 3.940248208281618112e-21 8.811398333442367119e-25 1.141255581418885481e-23 1.351996182873977715e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.372357481973014311e-21 0.000000000000000000e+00 3.929385059225085232e-21 6.481646391007786189e-20 7.888000422582814508e+02 6.335992848770473452e-20 6.359632795143814642e-20 9.479044760282632557e-21 1.068631024504358433e-27 3.938188886358169903e-21 8.783308133991326788e-25 1.138765042270327407e-23 1.351919873962363494e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.384102796392891103e-21 0.000000000000000000e+00 3.932206988711931484e-21 6.459743466981065515e-20 7.897000422101209551e+02 6.344712062779512248e-20 6.365783902994589556e-20 1.026556160247031793e-20 1.062969734484722920e-27 3.936129564434468917e-21 8.755219193638354047e-25 1.136274503121464146e-23 1.351843565178284202e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.410978209134500612e-21 0.000000000000000000e+00 3.935028918199123802e-21 6.477901064650373566e-20 7.906000421620698262e+02 6.251207073840392553e-20 6.371936077008057171e-20 1.006056550081498581e-20 1.057308444464399358e-27 3.934070242510518161e-21 8.727131524541015750e-25 1.133783963972298342e-23 1.351767256521760907e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.427679919147281424e-21 0.000000000000000000e+00 3.937850847686658424e-21 6.480799739946742707e-20 7.915000421141282914e+02 6.405083966207456177e-20 6.378089314099023365e-20 1.089384211894044889e-20 1.051731352067334401e-27 3.932021334787865374e-21 8.699045139013315007e-25 1.131293424822829114e-23 1.351698213686024095e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.464778706027310665e-21 0.000000000000000000e+00 3.940672777174537606e-21 6.500438577941176885e-20 7.924000420662954411e+02 6.139772926359166829e-20 6.384243611193652187e-20 1.134704985879002380e-20 1.046157158815202423e-27 3.930017133213711897e-21 8.670960049528273602e-25 1.128802885673059253e-23 1.351660361191833067e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.438935838524679543e-21 0.000000000000000000e+00 3.943493698383456182e-21 6.514126102823783382e-20 7.933000420185710482e+02 6.415844548734571134e-20 6.390398965229426136e-20 1.185783904858207407e-20 1.040607585199385207e-27 3.928012931639316926e-21 8.642876268720426242e-25 1.126312346522989200e-23 1.351622508827369031e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.380598792251895974e-21 0.000000000000000000e+00 3.946304718327555076e-21 6.529031404829214431e-20 7.942000419709551124e+02 6.356642968270899558e-20 6.396555373155084772e-20 1.055261980487229748e-20 1.035149985488128237e-27 3.925988140065900126e-21 8.614793809388470930e-25 1.123821807372619102e-23 1.351564068206064160e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.371566198755722901e-21 0.000000000000000000e+00 3.949115738271993266e-21 6.512610786486129356e-20 7.951000419234467245e+02 6.379878389055665492e-20 6.402712831930586196e-20 9.724516105172877398e-21 1.029692385776219270e-27 3.923946123366970166e-21 8.586712684497950561e-25 1.121331268221951310e-23 1.351488405281457978e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.491126679353605269e-21 0.000000000000000000e+00 3.951926758216766988e-21 6.506217650905875853e-20 7.960000418760458842e+02 6.495543717842866402e-20 6.408871338527046866e-20 1.209022185879262117e-20 1.024272230083758363e-27 3.921904106667795704e-21 8.558632907183921664e-25 1.118840729070985824e-23 1.351412742457073692e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.519542444934279046e-21 0.000000000000000000e+00 3.954737778161876996e-21 6.551894739031873777e-20 7.969000418287520233e+02 6.389779338751778225e-20 6.415030889926710300e-20 1.116151109873352823e-20 1.018901030366008110e-27 3.919903672932056616e-21 8.530554490753771912e-25 1.116350189919724407e-23 1.351337364546662556e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.514634674061382773e-21 0.000000000000000000e+00 3.957548798107321032e-21 6.541421041900068312e-20 7.978000417815649143e+02 6.360712751167914123e-20 6.421191483122879670e-20 9.868228367561011922e-21 1.013529830647620568e-27 3.917907857137115845e-21 8.502477448690008250e-25 1.113859650768167648e-23 1.351262018366134204e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.488509403191458490e-21 0.000000000000000000e+00 3.960359818053098345e-21 6.526565024694144752e-20 7.987000417344841026e+02 6.484362139424594071e-20 6.427353115119881687e-20 1.082121038292035837e-20 1.008205834267357591e-27 3.915904906097411139e-21 8.474401794653168076e-25 1.111369111616316574e-23 1.351186749008663727e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.383920306787804760e-21 0.000000000000000000e+00 3.963170837999207429e-21 6.547316504501986622e-20 7.996000416875094743e+02 6.584837994412728975e-20 6.433515782933014846e-20 9.833574019103515545e-21 1.002906634543944289e-27 3.913879906203103657e-21 8.446327542484719414e-25 1.108878572464171773e-23 1.351111716835070283e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.359664488505119386e-21 0.000000000000000000e+00 3.965981857945648284e-21 6.537700529984528261e-20 8.005000416406403474e+02 6.271219321146586905e-20 6.439679483588503684e-20 1.184361520333322233e-20 9.976074348199096629e-28 3.911854906308559196e-21 8.418254706210100660e-25 1.106388033311735010e-23 1.351036684761812710e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.361169855919492428e-21 0.000000000000000000e+00 3.968792877892418655e-21 6.576984778958750903e-20 8.014000415938763808e+02 6.307187430822110297e-20 6.445844214123443407e-20 9.815742381174313140e-21 9.924203959209007762e-28 3.909851574813522821e-21 8.390183300041729119e-25 1.103897494159007164e-23 1.350961652788907749e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.368097081548671048e-21 0.000000000000000000e+00 3.971603897839517787e-21 6.549605516643518683e-20 8.023000415472174609e+02 6.513983985364027918e-20 6.452009971585768596e-20 1.150456090053048088e-20 9.872489676175757923e-28 3.907864074916561217e-21 8.362113338382136266e-25 1.101406955005988677e-23 1.350886620916372513e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.365917411337459357e-21 0.000000000000000000e+00 3.974409070365970764e-21 6.583075345014428521e-20 8.032000415006630192e+02 6.229525070216590865e-20 6.458176753034187003e-20 8.833554647150952266e-21 9.820830981629095595e-28 3.905876575019369404e-21 8.334044835827161786e-25 1.098916415852681166e-23 1.350811589144223555e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.398946966957439418e-21 0.000000000000000000e+00 3.977213506578250324e-21 6.547892977209881039e-20 8.041000414542128283e+02 6.356378922772077554e-20 6.464344555538150662e-20 1.095839413099644242e-20 9.769830984261272290e-28 3.903896589333059150e-21 8.305977807169160466e-25 1.096425876699085070e-23 1.350770867519655088e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.384825262904401737e-21 0.000000000000000000e+00 3.980017942790854132e-21 6.585935393687796932e-20 8.050000414078665472e+02 6.264947400051172217e-20 6.470513376177798110e-20 1.117415926100365726e-20 9.718830986887560392e-28 3.901917336322948982e-21 8.277912267400328484e-25 1.093935337545201420e-23 1.350733491413286546e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.408080749395962501e-21 0.000000000000000000e+00 3.982822379003782188e-21 6.595701219383102009e-20 8.059000413616236074e+02 6.239664523416145079e-20 6.476683212043905036e-20 1.133872167513256097e-20 9.668139439481650163e-28 3.899931312664146085e-21 8.249848231716078356e-25 1.091444798391031830e-23 1.350687472058996895e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.416286065211541617e-21 0.000000000000000000e+00 3.985626815217032236e-21 6.604594425321527028e-20 8.068000413154840089e+02 6.297338487701289698e-20 6.482854060237855392e-20 1.078791939299280018e-20 9.618249678259784498e-28 3.897923048304292093e-21 8.221785715518457974e-25 1.088954259236576155e-23 1.350613060523362751e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.393957823367997907e-21 0.000000000000000000e+00 3.988431251430604276e-21 6.601344998073711748e-20 8.077500510677793955e+02 6.478990023679749154e-20 6.489368895607988266e-20 1.031592348075107003e-20 9.565587720337270758e-28 3.895803191832227576e-21 8.192165530781639633e-25 1.086325329673793822e-23 1.350534514312217012e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.416038854060602488e-21 0.000000000000000000e+00 3.991391520196347836e-21 6.600287068201055391e-20 8.087000412184153220e+02 6.352554411181014593e-20 6.495884717875876047e-20 1.031203513554151404e-20 9.513328456253527558e-28 3.893707760967933100e-21 8.162547686212849481e-25 1.083696454354014784e-23 1.350455969833719477e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.425848826995966370e-21 0.000000000000000000e+00 3.994351727882528480e-21 6.606674120348156989e-20 8.096000411725945014e+02 6.487616025245069868e-20 6.502058697112050910e-20 9.717049703392164450e-21 9.464147356395231093e-28 3.891736686688119371e-21 8.134489998114544613e-25 1.081205915198677047e-23 1.350381558610779808e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.442196901454221093e-21 0.000000000000000000e+00 3.997156164097093577e-21 6.603793326920191593e-20 8.105000411268755443e+02 6.537425132008314079e-20 6.508233676869871886e-20 1.169945440552750661e-20 9.414966256531368895e-28 3.889765612408082203e-21 8.106433895069878083e-25 1.078715376043057486e-23 1.350307147488383087e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.450789043172296622e-21 0.000000000000000000e+00 3.999960600311976903e-21 6.641948183576391079e-20 8.114000410812577684e+02 6.356525774412659149e-20 6.514409654304162665e-20 1.100460889813526821e-20 9.366312748064542848e-28 3.887810156667759692e-21 8.078379393593515125e-25 1.076224836887157862e-23 1.350233325843386018e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.461054812850359064e-21 0.000000000000000000e+00 4.002772613746015212e-21 6.636167587641494058e-20 8.123000410357411738e+02 6.442057606164335059e-20 6.520586626580078353e-20 1.204563565274938659e-20 9.317840309571105226e-28 3.885855238733840799e-21 8.050326510429355229e-25 1.073734297730978177e-23 1.350159524593512724e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.481633611414959243e-21 0.000000000000000000e+00 4.005588246710687285e-21 6.660351712899727350e-20 8.132500507224085595e+02 6.392873290474989342e-20 6.527107906970081381e-20 1.213988397137726728e-20 9.266674433533270313e-28 3.883791693102964818e-21 8.020716604789086614e-25 1.071105368349806049e-23 1.350081622585113590e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.482174961162002139e-21 0.000000000000000000e+00 4.008560334183818003e-21 6.668453319867583094e-20 8.142000409399810223e+02 6.400913776281345606e-20 6.533630155697111979e-20 1.097390280730335468e-20 9.216772850650995857e-28 3.881728189761516368e-21 7.991109148237938760e-25 1.068476492844795844e-23 1.350003722285344020e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.469452154263971702e-21 0.000000000000000000e+00 4.011532360748250397e-21 6.654577273113063400e-20 8.151000408947767255e+02 6.320348343692644438e-20 6.539810205018521269e-20 9.929026863517123872e-21 9.169522853024222916e-28 3.879773271826918884e-21 7.963061409465793912e-25 1.065985953687752023e-23 1.349929921348566938e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.485175504008223811e-21 0.000000000000000000e+00 4.014347993713899729e-21 6.644293400372448103e-20 8.160000408496722457e+02 6.591100414960769062e-20 6.545991237634652115e-20 1.121421831677425365e-20 9.122413453371022921e-28 3.877842535894141201e-21 7.935015360337012061e-25 1.063495414530431962e-23 1.349856120512461637e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.500813906019180682e-21 0.000000000000000000e+00 4.017163626679861272e-21 6.670839814133201388e-20 8.169500504926846816e+02 6.411786362603510401e-20 6.552516791199387253e-20 1.135570211101154935e-20 9.073323460922752103e-28 3.875817925179524969e-21 7.905412748343064905e-25 1.060866485270064653e-23 1.349778218944511586e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.498518369659177072e-21 0.000000000000000000e+00 4.020135714016417979e-21 6.679631475261089750e-20 8.179000407547775922e+02 6.416531991801210138e-20 6.559043300849379118e-20 1.009939629979906460e-20 9.024234469947678757e-28 3.873792188617756296e-21 7.875812664334708352e-25 1.058237609641854412e-23 1.349702389278379343e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.500778765669090164e-21 0.000000000000000000e+00 4.023107740720131971e-21 6.665860839574704880e-20 8.188000407099810900e+02 6.576381207612390983e-20 6.565227374880871076e-20 1.103949861204697416e-20 8.978039951414190596e-28 3.871853164324024784e-21 7.849264536434783447e-25 1.055837803958651225e-23 1.349665776797850551e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.512627394919560715e-21 0.000000000000000000e+00 4.025923373687056479e-21 6.686872131393726118e-20 8.197000406652830407e+02 6.460289438227941834e-20 6.571412420899676645e-20 9.916759103093296175e-21 8.932234506218279140e-28 3.869914140030081871e-21 7.826533865689508144e-25 1.053669637080906812e-23 1.349629164399957508e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.512537293576764908e-21 0.000000000000000000e+00 4.028739006654289437e-21 6.675349922863004317e-20 8.206500502650322915e+02 6.631924383056792062e-20 6.577942198279249421e-20 1.127542818452838066e-20 8.883883823087073041e-28 3.867867371380214954e-21 7.802551066267713377e-25 1.051380993247558569e-23 1.349576694540136872e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.508093801992334554e-21 0.000000000000000000e+00 4.031706915066879288e-21 6.703278823612638440e-20 8.216000405712421752e+02 6.769039177178906848e-20 6.584472919676197078e-20 1.012920319677486301e-20 8.836146811792251213e-28 3.865820644297730138e-21 7.778580081041513549e-25 1.049092395893782697e-23 1.349499431325315997e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.535445316080212580e-21 0.000000000000000000e+00 4.034670332483950742e-21 6.691488621131106081e-20 8.225000405268481245e+02 6.636169390456150083e-20 6.590660971949628544e-20 1.113306356825525307e-20 8.791216581450371004e-28 3.863881620003131957e-21 7.755881039817503230e-25 1.046924229015306098e-23 1.349426233935667432e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.517916196946433641e-21 0.000000000000000000e+00 4.037477809072261212e-21 6.713432863079226964e-20 8.234500500941147720e+02 6.848864650548970588e-20 6.597193913219538068e-20 1.161596351487788659e-20 8.743789747239538987e-28 3.861868315591337105e-21 7.731931929726524314e-25 1.044635585260210807e-23 1.349349193170465576e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.527400840004798773e-21 0.000000000000000000e+00 4.040441286572631583e-21 6.728057046349727257e-20 8.244000404334456107e+02 6.901911356370059768e-20 6.603727789495864506e-20 1.098340469928638940e-20 8.697052840488692198e-28 3.859868335929588269e-21 7.707994944705547434e-25 1.042346987826644142e-23 1.349272242911001359e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.525709060277501053e-21 0.000000000000000000e+00 4.043404704093020902e-21 6.723841764067331935e-20 8.253000403893523753e+02 6.688477784169962521e-20 6.609918821782321097e-20 1.077010669313863970e-20 8.652852070453425951e-28 3.857971687877593780e-21 7.685328407622469636e-25 1.040178820947442704e-23 1.349199361614000994e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.525545979790095282e-21 0.000000000000000000e+00 4.046212180682270263e-21 6.726479383744239876e-20 8.262500499243556078e+02 6.550722827683609292e-20 6.616454899346457661e-20 9.637552492632262137e-21 8.606280212150840098e-28 3.855941425564885406e-21 7.661413920809622150e-25 1.037890177270072569e-23 1.349122720151879334e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.531597115645755520e-21 0.000000000000000000e+00 4.049175658081996500e-21 6.715745151301349948e-20 8.272000402965819603e+02 6.843036109875690918e-20 6.622991903008589681e-20 1.105955653810790565e-20 8.560357897632408795e-28 3.853911204204885801e-21 7.637511881119362738e-25 1.035601579757258043e-23 1.349046080326301409e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.527432018371039493e-21 0.000000000000000000e+00 4.052139075705001022e-21 6.744031712540207868e-20 8.281000402527864708e+02 6.902969288322789075e-20 6.629185889358588457e-20 9.077877260337347955e-21 8.516852108243680816e-28 3.852003141405447597e-21 7.614878754019971970e-25 1.033433412877339405e-23 1.348973473527038383e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.555667126211009276e-21 0.000000000000000000e+00 4.054946552295178742e-21 6.720602801932890215e-20 8.290500497557430890e+02 6.741419121509474622e-20 6.635725075927815122e-20 1.178783565314364500e-20 8.471292670533506719e-28 3.850011185996022533e-21 7.590999857850544273e-25 1.031144769277171773e-23 1.348896832334577384e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.530690384159083219e-21 0.000000000000000000e+00 4.057910029594939435e-21 6.768863302684411903e-20 8.300000401606416744e+02 6.633145400166928991e-20 6.642265179787800533e-20 1.087748773764127441e-20 8.426450211574308779e-28 3.848019270630912792e-21 7.567133742513767348e-25 1.028856171685647466e-23 1.348820192773479294e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.546460414417750283e-21 0.000000000000000000e+00 4.060874448256044433e-21 6.760096336531068233e-20 8.309000401171410886e+02 6.647617903873684206e-20 6.648462094540102860e-20 1.047475057967806344e-20 8.383967455006980115e-28 3.846109954770743636e-21 7.544534963804145894e-25 1.026688004805018390e-23 1.348747812952912140e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.530690017301795345e-21 0.000000000000000000e+00 4.063684886312721867e-21 6.759774358071577186e-20 8.318500495882656196e+02 6.710408716522830746e-20 6.655004363128198967e-20 1.083608411600569816e-20 8.339436770140575186e-28 3.844087846257908097e-21 7.520692660498609027e-25 1.024399361281536776e-23 1.348671479714727456e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.541080139407645687e-21 0.000000000000000000e+00 4.066651489535945785e-21 6.771941967074055839e-20 8.328000400256154307e+02 6.706153440174905223e-20 6.661547540299645282e-20 1.080388609430536882e-20 8.295176679266347595e-28 3.842071116746719885e-21 7.496863483896060713e-25 1.022110763611835043e-23 1.348595183450728093e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.560340586493094086e-21 0.000000000000000000e+00 4.069618033322228674e-21 6.777936984975570331e-20 8.337500494752609939e+02 6.668111319752389644e-20 6.668091885040785977e-20 1.082301203419039189e-20 8.250915702608532768e-28 3.840095097091457515e-21 7.473046600668923059e-25 1.019822120140097661e-23 1.348519155618715102e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.555790205636902193e-21 0.000000000000000000e+00 4.072584636478379825e-21 6.784663201849724329e-20 8.347000399345065489e+02 6.912005703885183828e-20 6.674637132512850039e-20 1.051019261479896456e-20 8.207247025900466270e-28 3.838119116936226868e-21 7.449243086035178446e-25 1.017533522417647529e-23 1.348443129397219838e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.576978200484545848e-21 0.000000000000000000e+00 4.075551180333036236e-21 6.786267552390464723e-20 8.356500493627700052e+02 7.080323091617751566e-20 6.681183541211062282e-20 1.069842071777667289e-20 8.163735143689926716e-28 3.836146909686691785e-21 7.425452112852350364e-25 1.015244878997421339e-23 1.348367248377279809e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.564686448397340140e-21 0.000000000000000000e+00 4.078517783422417803e-21 6.795604242339736731e-20 8.366000398438113734e+02 6.733241505816178560e-20 6.687730846832719848e-20 9.925969437304760524e-21 8.120252204726336709e-28 3.834178801917203977e-21 7.401674756166609837e-25 1.012956281222463343e-23 1.348291525120517102e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.575576021366295779e-21 0.000000000000000000e+00 4.081484327345136277e-21 6.790368387408721158e-20 8.375500492507895842e+02 6.723877081476111215e-20 6.694279307383568847e-20 9.605356141509207004e-21 8.077628208519709017e-28 3.832210654938602936e-21 7.377910195113879252e-25 1.010667637853515009e-23 1.348215800445981818e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.551425545820261701e-21 0.000000000000000000e+00 4.084450930368050691e-21 6.792125256418422842e-20 8.385000397535272896e+02 6.598157709385477457e-20 6.700828659094922255e-20 1.003712224043402835e-20 8.035005060488130706e-28 3.830242547124166481e-21 7.354159504652588163e-25 1.008379040026288951e-23 1.348171951372430232e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.580848192670394960e-21 0.000000000000000000e+00 4.087417474358520522e-21 6.804932388739388049e-20 8.394500491393159791e+02 6.766984532266950358e-20 6.707379159484685720e-20 1.094029543052420775e-20 7.992575106130160390e-28 3.828274400189465358e-21 7.330421870293732165e-25 1.006090396708387633e-23 1.348134075754718373e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.569753475237082791e-21 0.000000000000000000e+00 4.090385931249734291e-21 6.825241186313237600e-20 8.404000396636513415e+02 6.664076250143142654e-20 6.713930545316150180e-20 1.103829289076241635e-20 7.950689160284464335e-28 3.826307854662307372e-21 7.306698366994583685e-25 1.003801798829131257e-23 1.348088689790683192e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.612115384282207112e-21 0.000000000000000000e+00 4.093365321616031406e-21 6.833423087532388116e-20 8.413500490283458930e+02 6.646826414224397104e-20 6.720483073621016658e-20 1.004899064123236416e-20 7.908802383750204509e-28 3.824347517878016803e-21 7.282988186741408641e-25 1.001513155562047295e-23 1.348013266874835111e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.599776923420571146e-21 0.000000000000000000e+00 4.096344771070059330e-21 6.824553642740093147e-20 8.423000395741809143e+02 6.679571222055859968e-20 6.727036481692513772e-20 1.172023495256840987e-20 7.867195248819710053e-28 3.822387219926293080e-21 7.259292404579550618e-25 9.992245576309965802e-24 1.347937847513102098e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.588299391267209373e-21 0.000000000000000000e+00 4.099324161503783553e-21 6.857548631353108110e-20 8.432500489178759153e+02 6.603831974584311596e-20 6.733591026077772551e-20 1.230507076700768301e-20 7.825884236449942184e-28 3.820431124753772560e-21 7.235610219074375074e-25 9.969359144145022220e-24 1.347862589867112495e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.577595446053175340e-21 0.000000000000000000e+00 4.102303610891952197e-21 6.874172675951516018e-20 8.442000394851132796e+02 6.871691087441597701e-20 6.740146444597939475e-20 1.163646021513958234e-20 7.784574040571590090e-28 3.818478574971308482e-21 7.211942705451247042e-25 9.946473164318916800e-24 1.347787468653683992e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.588642671018440127e-21 0.000000000000000000e+00 4.105283001392799592e-21 6.869000250648936921e-20 8.451500488079026354e+02 6.637216847193539845e-20 6.746702993317183732e-20 1.082917176385085178e-20 7.743985900176159749e-28 3.816525986639883532e-21 7.188289068962229657e-25 9.923586732657604956e-24 1.347712346028478499e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.589668241462905535e-21 0.000000000000000000e+00 4.108262450715403111e-21 6.862242774215957679e-20 8.461000393964455952e+02 6.632695203039990333e-20 6.753260410582572713e-20 1.336902754320550710e-20 7.703700584992833305e-28 3.814580234306488877e-21 7.164650385107502002e-25 9.900700752318231683e-24 1.347637486397367215e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.594690766875024726e-21 0.000000000000000000e+00 4.111241841283069743e-21 6.913309983006912866e-20 8.470500486984225290e+02 6.776486697165644355e-20 6.759818951976923121e-20 1.217203755524687886e-20 7.663414476247344590e-28 3.812635333373308173e-21 7.141025865937290221e-25 9.877814321158306383e-24 1.347562659583238336e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.606082178592256276e-21 0.000000000000000000e+00 4.114221290540400787e-21 6.897640478550646613e-20 8.480500486409986252e+02 6.668038721847090924e-20 6.766723683465480407e-20 1.271321742407659406e-20 7.621555861323665445e-28 3.810588089396380734e-21 7.116174161658827890e-25 9.853723578259187396e-24 1.347483895368593634e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.611844253307398546e-21 0.000000000000000000e+00 4.117357522027860034e-21 6.914182231843791868e-20 8.490000392618759406e+02 6.781875500219672602e-20 6.773284129080515924e-20 1.100308338649257925e-20 7.581841967699019454e-28 3.808643226707970800e-21 7.092580595580200369e-25 9.830837597140856628e-24 1.347409070172390917e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.633677971646367075e-21 0.000000000000000000e+00 4.120336912696934400e-21 6.891328203508467866e-20 8.499500485322653276e+02 6.768454234520687804e-20 6.779845689644641213e-20 1.253092298401852998e-20 7.542218225262476024e-28 3.806698325839456955e-21 7.069001647200752932e-25 9.807951166741897882e-24 1.347334243578677386e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.620014405573659021e-21 0.000000000000000000e+00 4.123309522386219308e-21 6.923747037318018758e-20 8.509000391742067677e+02 6.742258438068542134e-20 6.786408104824677996e-20 1.067726806792401541e-20 7.503080034021443919e-28 3.804762420427392205e-21 7.045438393157268519e-25 9.785065185116116489e-24 1.347259763035017312e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.646667958263063673e-21 0.000000000000000000e+00 4.126281761519374221e-21 6.899173881388217460e-20 8.518500484240169044e+02 6.642488913061287290e-20 6.792971628994546375e-20 1.257329299875390659e-20 7.463941076164098870e-28 3.802832714138715714e-21 7.021890063198200607e-25 9.762178755212928363e-24 1.347185520989551872e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.668015591249646915e-21 0.000000000000000000e+00 4.129254058871035097e-21 6.937564154381377873e-20 8.528500483672379460e+02 6.791817588598023599e-20 6.799881590227701009e-20 1.180272185453713851e-20 7.423084618036681068e-28 3.800801464254048156e-21 6.997119382471597874e-25 9.738088012298272279e-24 1.347107372310550487e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.827166907102384132e-21 0.000000000000000000e+00 4.132382762284702841e-21 6.931430986935625138e-20 8.538000390411484659e+02 6.671675512417223797e-20 6.806446989636309398e-20 1.061377289876852856e-20 7.384801411774614433e-28 3.798906953472712281e-21 6.973603582128291162e-25 9.715202029902331966e-24 1.347033131863453992e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.718040440707647686e-21 0.000000000000000000e+00 4.135355001517880474e-21 6.918207448043456805e-20 8.547500482597237124e+02 6.859015213454326085e-20 6.813013489022197708e-20 1.091176890286363506e-20 7.346517458190237640e-28 3.797014356982581579e-21 6.950103188740233121e-25 9.692315600751614508e-24 1.346958890038599313e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.686150131255455634e-21 0.000000000000000000e+00 4.138327298771816204e-21 6.929180937752568998e-20 8.557500482033291291e+02 6.882735384842366751e-20 6.819926572968376415e-20 1.323056083362079415e-20 7.306576524864106983e-28 3.795010839586988050e-21 6.925383492002587802e-25 9.668224857827699937e-24 1.346880741589256986e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.698371778829323904e-21 0.000000000000000000e+00 4.141456002186686902e-21 6.976271742896643984e-20 8.567000389089910186e+02 7.009498137016531352e-20 6.826494930347951160e-20 1.054268521687040983e-20 7.268859421754557055e-28 3.793081170966112087e-21 6.901916631214000383e-25 9.645338874666844879e-24 1.346806501357919188e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.712503542052192419e-21 0.000000000000000000e+00 4.144428241519204904e-21 6.936848651898034532e-20 8.576500480965416955e+02 6.755617718725001441e-20 6.833064378821716367e-20 1.071906217901481525e-20 7.231141584865928700e-28 3.791151464803899980e-21 6.884948755624871616e-25 9.623682216018128565e-24 1.346732259753769121e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.775560195388974069e-21 0.000000000000000000e+00 4.147400538676073766e-21 6.946269826629308207e-20 8.586500480405273947e+02 6.905751685972596061e-20 6.839980558125384569e-20 1.196961752005480235e-20 7.192041251060494560e-28 3.789154556198957007e-21 6.877477766663158702e-25 9.602709748787229953e-24 1.346654493103049837e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.737600221823730949e-21 0.000000000000000000e+00 4.150529242092134628e-21 6.973304638658280518e-20 8.596500479846436065e+02 6.850136508054910116e-20 6.846897798462358474e-20 9.752567328423057402e-21 7.153082145430984673e-28 3.787177812123379196e-21 6.871114102910962659e-25 9.581737281553595377e-24 1.346576950581381735e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.745018120001323931e-21 0.000000000000000000e+00 4.153661845576728082e-21 6.945543624877118664e-20 8.606000387326662349e+02 6.993835169226505919e-20 6.853470092992552824e-20 1.021308500502870876e-20 7.116122504537186754e-28 3.785299921934160744e-21 6.866097136432052479e-25 9.561813630605025378e-24 1.346503285972556535e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.700759051214599458e-21 0.000000000000000000e+00 4.156638914378492411e-21 6.958466599682261669e-20 8.615500478788218288e+02 6.808563341552989306e-20 6.860043466753647326e-20 1.268416219934590511e-20 7.079804811717364555e-28 3.783385174817878345e-21 6.862084424245693984e-25 9.541889593802192086e-24 1.346429620008679940e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.708391291759746743e-21 0.000000000000000000e+00 4.159616040836089481e-21 7.005478116368592605e-20 8.625500478233133208e+02 6.868932426562253610e-20 6.866963765964811734e-20 1.053194395838703203e-20 7.041576031551564872e-28 3.781369671053787070e-21 6.858947516960959638e-25 9.520917126560687575e-24 1.346352077717003420e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.688799642802883099e-21 0.000000000000000000e+00 4.162749827815286561e-21 6.976468032695867126e-20 8.635500477679333926e+02 6.798154090996679127e-20 6.873885113750611960e-20 1.228780353392974692e-20 7.003530305413578079e-28 3.779371334511018518e-21 6.856926932402596376e-25 9.499944659316485305e-24 1.346274646260664192e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.684629553165992152e-21 0.000000000000000000e+00 4.165883614794887634e-21 7.011902585852747678e-20 8.645000385579324984e+02 6.614530260394731309e-20 6.880461299111016025e-20 1.103026457710913488e-20 6.967774194498482775e-28 3.777500696275885119e-21 6.856042279838641293e-25 9.480021007487564077e-24 1.346201266276590502e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.699979014372607775e-21 0.000000000000000000e+00 4.168860683728196740e-21 6.997494302445986365e-20 8.654500476630641970e+02 6.737968681698793615e-20 6.887038552043835733e-20 1.076130471177983512e-20 6.932017394231533839e-28 3.775630021976205117e-21 6.856166386303591472e-25 9.460096971545104488e-24 1.346127884949446055e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.703767910562616198e-21 0.000000000000000000e+00 4.171837810057233472e-21 6.999798429076499781e-20 8.664500476080545468e+02 6.922981846501585953e-20 6.893962922846009329e-20 1.226081098339082367e-20 6.894742360349752567e-28 3.773666060461123233e-21 6.857386764891065555e-25 9.439124504293136608e-24 1.346050846075922118e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.701295871164422393e-21 0.000000000000000000e+00 4.174971597037994618e-21 7.031201781581179921e-20 8.674500475531718848e+02 6.942713716261133819e-20 6.900888329951248140e-20 1.216184097821756453e-20 6.857830597669684939e-28 3.771704522107239588e-21 6.859724228486416364e-25 9.418152037038504764e-24 1.345973902757574309e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.733867251940406732e-21 0.000000000000000000e+00 4.178105384019152986e-21 7.036408483663751374e-20 8.684500474984155289e+02 6.912685889062502269e-20 6.907814770242727050e-20 1.235100260400757961e-20 6.820918834984955583e-28 3.769743585347923268e-21 6.863177635718477059e-25 9.397179569781225120e-24 1.345896983095086216e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.715884405547279510e-21 0.000000000000000000e+00 4.181239171000707825e-21 7.046431038900727659e-20 8.694000383406172432e+02 7.014738014066899929e-20 6.914395779595311488e-20 9.911683826953054835e-21 6.786272599491123369e-28 3.767887281403391196e-21 6.867490442070226626e-25 9.377255916857486657e-24 1.345824167748176451e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.721362504304397662e-21 0.000000000000000000e+00 4.184224509131108668e-21 7.014306972365186094e-20 8.703500473947250384e+02 7.027381892337190211e-20 6.920977842114420586e-20 1.163450761090611269e-20 6.751752123971895268e-28 3.766030941872376481e-21 6.872807071344956547e-25 9.357331881985123656e-24 1.345751351063113069e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.721859582496847510e-21 0.000000000000000000e+00 4.187215618940091611e-21 7.047191365689227481e-20 8.713500473403327078e+02 6.913457263679035933e-20 6.927907261131157582e-20 1.228029065025918668e-20 6.715415129611352879e-28 3.764062740931137557e-21 6.879485272845288186e-25 9.336359414720209176e-24 1.345674702718029999e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.742531142788411009e-21 0.000000000000000000e+00 4.190364125402588805e-21 7.065023117637290518e-20 8.723500472860650916e+02 6.968565049382504678e-20 6.934837701292890850e-20 1.274267752277661452e-20 6.679758899591257746e-28 3.762070403874506288e-21 6.887269830611103404e-25 9.315386947452679220e-24 1.345598054436959085e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.738521035857030585e-21 0.000000000000000000e+00 4.193512631865478707e-21 7.079987405026115107e-20 8.733500472319218488e+02 6.932515026378364320e-20 6.941769159541183453e-20 1.131395044299328101e-20 6.644138463563658998e-28 3.760078066817627507e-21 6.896156997994388675e-25 9.294414480182541137e-24 1.345521406219911424e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.744384284591132324e-21 0.000000000000000000e+00 4.196661138328760567e-21 7.062516331066822911e-20 8.743500471779022973e+02 7.044285597625872769e-20 6.948701632829356255e-20 1.347776773721457933e-20 6.608667443971410561e-28 3.758120518852175208e-21 6.906142518318316914e-25 9.273442012909808149e-24 1.345444980360918353e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.775298628574963210e-21 0.000000000000000000e+00 4.199809644792431374e-21 7.107299151872089244e-20 8.753500471240063234e+02 7.006598427574068720e-20 6.955635118122431351e-20 1.103452759377621003e-20 6.573758354943778668e-28 3.756173954071591339e-21 6.917221634924157291e-25 9.252469545634483197e-24 1.345368624745918071e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.776601533539660277e-21 0.000000000000000000e+00 4.202958151256491881e-21 7.071873943840663911e-20 8.763500470702332450e+02 7.071858683066430202e-20 6.962569612397071877e-20 1.153224260456029421e-20 6.538849265911857232e-28 3.754228425833387987e-21 6.929389102295297855e-25 9.231497078356582442e-24 1.345292309843623525e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.771745181252973619e-21 0.000000000000000000e+00 4.206106657720938326e-21 7.086612881325486877e-20 8.773000379953638230e+02 6.947584476082781469e-20 6.969158251194566112e-20 1.033590931362128189e-20 6.505916086246198739e-28 3.752386238107850324e-21 6.941950950675956554e-25 9.211573423693620742e-24 1.345220048553334096e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.773671865396283597e-21 0.000000000000000000e+00 4.209097710450716468e-21 7.074636074248420152e-20 8.782500469684018753e+02 6.997050338112360420e-20 6.975747920485868440e-20 1.178397325701549368e-20 6.473285343259239412e-28 3.750544015384467937e-21 6.955484828655817495e-25 9.191649390521491301e-24 1.345147785948081015e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.802631019568689514e-21 0.000000000000000000e+00 4.212088820004450498e-21 7.103830270738024038e-20 8.792500469149831588e+02 6.826997419026002203e-20 6.982685323816960576e-20 1.096749254198424629e-20 6.438937519007099627e-28 3.748623395994350085e-21 6.970774504813633440e-25 9.170676923236157014e-24 1.345071838947270678e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.810619174802604046e-21 0.000000000000000000e+00 4.215235311740380472e-21 7.097608466861656833e-20 8.802500468616858598e+02 7.066583771946635107e-20 6.989623724448909604e-20 1.209790153120537840e-20 6.404850584690652366e-28 3.746729456701352862e-21 6.987127643981261002e-25 9.149704455948276312e-24 1.344996061947141161e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.823632859372370313e-21 0.000000000000000000e+00 4.218377909589306551e-21 7.122820998272344647e-20 8.812500468085095235e+02 7.050440596943490394e-20 6.996563119414683221e-20 1.094225816355578479e-20 6.370937543015762908e-28 3.744835517408126182e-21 7.004536797722519455e-25 9.128731988657859482e-24 1.344920285011146617e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.803458480337411145e-21 0.000000000000000000e+00 4.221520507438611798e-21 7.110862018355324462e-20 8.822500467554535817e+02 7.040530549465825100e-20 7.003503505758586835e-20 1.027095385496640649e-20 6.337024501336790178e-28 3.742918023225353625e-21 7.022994112844631193e-25 9.107759521364918277e-24 1.344844728277984791e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.814315345431090408e-21 0.000000000000000000e+00 4.224663105288296212e-21 7.107731638111496002e-20 8.832500467025179205e+02 6.860812766439104044e-20 7.010444880536206986e-20 1.198211758900937661e-20 6.303699531901929906e-28 3.740993495025342756e-21 7.042491348130793314e-25 9.086787054069452699e-24 1.344769237347324512e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.790556027305402396e-21 0.000000000000000000e+00 4.227805703138358289e-21 7.141197342128771562e-20 8.842500466497019715e+02 6.906031760192428728e-20 7.017387240814362000e-20 1.183816548169290853e-20 6.270486537266214216e-28 3.739068966825101677e-21 7.063019891589886820e-25 9.065814586771477439e-24 1.344693746480839831e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.785723317331094167e-21 0.000000000000000000e+00 4.230948300988796524e-21 7.145603284083916816e-20 8.852500465970053938e+02 6.909667685836909985e-20 7.024330583671055038e-20 1.228118139471316791e-20 6.237330389831794900e-28 3.737144438624631142e-21 7.084570778145121832e-25 9.044842119470999847e-24 1.344618255678541843e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.786198383589020530e-21 0.000000000000000000e+00 4.234090898839610165e-21 7.159898174982366568e-20 8.862500465444276188e+02 6.969932101558448489e-20 7.031274906195409102e-20 1.193346646540767805e-20 6.204928957843635603e-28 3.735219910423931903e-21 7.107134707683712025e-25 9.023869652168028737e-24 1.344542764940441269e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.783823552505400104e-21 0.000000000000000000e+00 4.237233496690796955e-21 7.160833658708053315e-20 8.872500464919684191e+02 7.149036232415944554e-20 7.038220205487633326e-20 1.243061712321742164e-20 6.172527525851633384e-28 3.733298783041714771e-21 7.130702063390660533e-25 9.002897184862571456e-24 1.344467407631715913e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.788416062291547262e-21 0.000000000000000000e+00 4.240376094542356894e-21 7.176124201608657669e-20 8.882500464396273401e+02 7.056493501019835385e-20 7.045166478658962794e-20 1.117138521902224337e-20 6.140206393910177368e-28 3.731381489908985434e-21 7.155262930291045485e-25 8.981924717554638290e-24 1.344392200749641691e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.808801429415261205e-21 0.000000000000000000e+00 4.243518692394287724e-21 7.162307180424467217e-20 8.892500463874039269e+02 6.916215077666963074e-20 7.052113722831606779e-20 1.119668958446377638e-20 6.108091700246813662e-28 3.729464196776030401e-21 7.180807113927224758e-25 8.960952250244235117e-24 1.344316993931805509e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.822768439641130374e-21 0.000000000000000000e+00 4.246662361450967865e-21 7.169599004610605676e-20 8.903000561608430417e+02 6.997394770941443627e-20 7.059409439409597657e-20 1.172934165542589220e-20 6.074370956268266771e-28 3.727489407938496208e-21 7.208675623906859781e-25 8.938930953445153437e-24 1.344238268296892548e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.795347028211516676e-21 0.000000000000000000e+00 4.249969450117212224e-21 7.185179927155399270e-20 8.913500462781162241e+02 7.027338939048837985e-20 7.066706083463519459e-20 9.236711702890636434e-21 6.041055688402061445e-28 3.725523134310643794e-21 7.237603789984780534e-25 8.916910068884390978e-24 1.344159598453818335e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.827001306257766037e-21 0.000000000000000000e+00 4.253276476874810917e-21 7.156059666428294252e-20 8.923500462262553583e+02 7.040039696701253645e-20 7.073656319569671774e-20 1.165411878606174645e-20 6.009627118603401962e-28 3.723643195614215416e-21 7.266128758975139217e-25 8.895937601566385295e-24 1.344084742645793283e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.810697411456258479e-21 0.000000000000000000e+00 4.256426055648638838e-21 7.198033899776891878e-20 8.933500461745104531e+02 6.974898385446487339e-20 7.080607514991913762e-20 1.192198329814582040e-20 5.978198548801097759e-28 3.721740210638058397e-21 7.295592723302730547e-25 8.874965134245947808e-24 1.344010099295854350e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.818061599669955206e-21 0.000000000000000000e+00 4.259575634422832385e-21 7.209283745492280243e-20 8.943500461228813947e+02 6.927129552135043967e-20 7.087559666907673516e-20 1.053397775542650353e-20 5.947195728303875324e-28 3.719837225661680950e-21 7.325984353499114067e-25 8.853992666923079986e-24 1.343935455996326634e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.823910630953090348e-21 0.000000000000000000e+00 4.262725213197390805e-21 7.194514311938986448e-20 8.953500460713676148e+02 6.962559556465932910e-20 7.094512772505046370e-20 1.101914365319105940e-20 5.916306050179817453e-28 3.717955137926552621e-21 7.357292153518770038e-25 8.833020199597795055e-24 1.343860812747218409e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.823969810355052574e-21 0.000000000000000000e+00 4.265874791972312593e-21 7.208629827407691354e-20 8.963500460199686586e+02 7.132749066361821879e-20 7.101466828982761204e-20 1.159130685691737124e-20 5.885416372052213512e-28 3.716089466380655331e-21 7.389504478505845238e-25 8.812047732270101829e-24 1.343786169548538139e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.835783537433390793e-21 0.000000000000000000e+00 4.269024370747596246e-21 7.224488151214957052e-20 8.973500459686844124e+02 6.978955275685551317e-20 7.108421833550127472e-20 1.114134314128873499e-20 5.854945218889897052e-28 3.714223794834544384e-21 7.422609552213176510e-25 8.791075264940003248e-24 1.343711526400294476e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.835721485851627504e-21 0.000000000000000000e+00 4.272173949523240259e-21 7.224257406031234914e-20 8.984000556544951905e+02 7.030446785505626914e-20 7.115725673471156445e-20 1.192879055799847109e-20 5.822959158710038149e-28 3.712277674713898370e-21 7.398970528193926674e-25 8.770696062800872980e-24 1.343633664547913287e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.836559733103700348e-21 0.000000000000000000e+00 4.275481037913492838e-21 7.244006815183509634e-20 8.994500458613586034e+02 7.177019771579311690e-20 7.123030416908292368e-20 1.248278081733149714e-20 5.791146335442166139e-28 3.710333248404891246e-21 7.332221421387258524e-25 8.751525532421852043e-24 1.343555870503835703e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.829219270856492822e-21 0.000000000000000000e+00 4.278788832447071451e-21 7.260482323390829411e-20 9.004500458104270137e+02 7.046900738591704244e-20 7.129988342985771509e-20 1.301044359017766272e-20 5.761323015406345018e-28 3.708471024580304772e-21 7.269078102188760111e-25 8.733267715084771244e-24 1.343481780302542135e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.820496129980557111e-21 0.000000000000000000e+00 4.281954458027242331e-21 7.276532917095109040e-20 9.014500457596084289e+02 7.165358350707907634e-20 7.136947205820197049e-20 1.261857192242432014e-20 5.731499695367154503e-28 3.706582135787406319e-21 7.206363354171607641e-25 8.715009897745625983e-24 1.343407690151732570e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.833031405830814360e-21 0.000000000000000000e+00 4.285120083607770561e-21 7.276511383985626872e-20 9.024500457089025076e+02 7.060132633438908147e-20 7.143907002674089481e-20 1.414070553119710646e-20 5.701862967144633601e-28 3.704693246994294960e-21 7.144088464047545655e-25 8.696752080404425077e-24 1.343333600051415848e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.826983393204546796e-21 0.000000000000000000e+00 4.288285709188655389e-21 7.311231689663468302e-20 9.035000553403414187e+02 7.023872080365484113e-20 7.151215859041755107e-20 1.148955284300482973e-20 5.670993426036606459e-28 3.702737536272432732e-21 7.079185330582220066e-25 8.677581195375033649e-24 1.343255976999436475e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.840191410405956865e-21 0.000000000000000000e+00 4.291609646706657324e-21 7.271862161155498056e-20 9.045500456027848486e+02 7.266347776908368449e-20 7.158525604181272474e-20 1.302284678969096257e-20 5.640124454363357703e-28 3.700800284865710426e-21 7.014794944099396919e-25 8.658410663981242234e-24 1.343178470221356870e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.841836042371081932e-21 0.000000000000000000e+00 4.294933522909669462e-21 7.304838145879113079e-20 9.055500455524256722e+02 7.092784314496724551e-20 7.165488279209754766e-20 1.131994422407946208e-20 5.611270274709497631e-28 3.698955266508439207e-21 6.953958796425840932e-25 8.640152846633709821e-24 1.343104653613181378e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.840531988354370203e-21 0.000000000000000000e+00 4.298099148491651919e-21 7.283262949229996096e-20 9.065500455021774542e+02 7.390441256969602532e-20 7.172451877141132793e-20 1.256634623718988809e-20 5.582638697200815519e-28 3.697116828120996893e-21 6.893612161283632410e-25 8.621895029284152619e-24 1.343031100253864328e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.821928441536403297e-21 0.000000000000000000e+00 4.301264774073985709e-21 7.310442045265546789e-20 9.076000550903465864e+02 7.085993246895899319e-20 7.179764712453513374e-20 1.141058922364146220e-20 5.552575264781656964e-28 3.695186663436863090e-21 6.830788652360464204e-25 8.602724145044772741e-24 1.342953877105733043e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.831421453509978067e-21 0.000000000000000000e+00 4.304588711455011895e-21 7.298704073011363955e-20 9.086500453970164699e+02 7.204286522812882191e-20 7.187078424911900885e-20 1.248870697730671077e-20 5.522781870849499140e-28 3.693256534196660764e-21 6.768535705876916686e-25 8.583553612843503400e-24 1.342876655431410243e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.832794168772006560e-21 0.000000000000000000e+00 4.307912587798027855e-21 7.323526336328552524e-20 9.096500453471104493e+02 7.657919187023238761e-20 7.194044866820714827e-20 1.209403563447885061e-20 5.494430995071395630e-28 3.691418298994282154e-21 6.709790528357786532e-25 8.565295795487696976e-24 1.342803110356232585e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.832643443832299589e-21 0.000000000000000000e+00 4.311078213381444980e-21 7.323751006020485437e-20 9.106500452973140227e+02 7.225897804593922442e-20 7.201012220685663792e-20 1.322965351968230323e-20 5.466137200816014682e-28 3.689580063791701922e-21 6.651590270029622222e-25 8.547037978129890743e-24 1.342729565331628831e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.825502184625999008e-21 0.000000000000000000e+00 4.314240390797666158e-21 7.350165686887081162e-20 9.117000548426002524e+02 7.173527316494258868e-20 7.208328987725553403e-20 1.259233262746398013e-20 5.436913158926230608e-28 3.687659024009853854e-21 6.591081710805263339e-25 8.527867094673459162e-24 1.342652707396689932e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.822654434948116429e-21 0.000000000000000000e+00 4.317559927455785101e-21 7.346140374948215724e-20 9.127500451930967529e+02 7.043706557701558880e-20 7.215646620467137268e-20 1.389213050173797029e-20 5.407689651269055082e-28 3.685742983224275854e-21 6.531208076456428525e-25 8.508696561672011715e-24 1.342576049477349819e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.843380553009383820e-21 0.000000000000000000e+00 4.320879403430829164e-21 7.376780464012011666e-20 9.137500451436378626e+02 6.922671289008934711e-20 7.222616784633944940e-20 1.046512723740689310e-20 5.380037791198183953e-28 3.683918165796281741e-21 6.474790403468303658e-25 8.490438744308041483e-24 1.342503041319671463e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.847438274560770894e-21 0.000000000000000000e+00 4.324040838018581388e-21 7.326880020673202548e-20 9.148000546567540141e+02 7.067734369758453897e-20 7.229936493535587389e-20 1.283526675828064499e-20 5.351354604498426206e-28 3.682002090042419785e-21 6.416204270314358607e-25 8.471267861438966226e-24 1.342426382110272004e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.859086049395033978e-21 0.000000000000000000e+00 4.327360374574996184e-21 7.371703998274615125e-20 9.158500450401255648e+02 7.048486301794403015e-20 7.237257059604381006e-20 1.242174493588932667e-20 5.322671940367300864e-28 3.680086049196851324e-21 6.358306271400678105e-25 8.452097327837290792e-24 1.342349724353325589e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.858234242086565875e-21 0.000000000000000000e+00 4.330679850653972756e-21 7.371809832624095350e-20 9.168500449910008001e+02 7.188946254460866945e-20 7.244230008951465154e-20 1.151788778747137285e-20 5.295651571769005633e-28 3.678263554561816576e-21 6.303820914082039637e-25 8.433839510467221214e-24 1.342276809264182987e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.862056922482377895e-21 0.000000000000000000e+00 4.333841285242781231e-21 7.364002670283205265e-20 9.179000544721632195e+02 7.181947160432433471e-20 7.251552633438998578e-20 1.162167572353328765e-20 5.267505484287846608e-28 3.676354446414248175e-21 6.247318309068111248e-25 8.414668628181551150e-24 1.342200430203043969e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.873826509364192226e-21 0.000000000000000000e+00 4.337160821698176488e-21 7.372890819877379551e-20 9.189500448881864259e+02 6.951503446315046505e-20 7.258876106659578536e-20 1.083030593764039627e-20 5.239359907858335344e-28 3.674445372930569750e-21 6.191561034462505528e-25 8.395498093983728165e-24 1.342124052928598248e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.882542780481031335e-21 0.000000000000000000e+00 4.340480297880379143e-21 7.368090321530848704e-20 9.200000543478245163e+02 6.941992613825598375e-20 7.266200691445736020e-20 1.151027076453937594e-20 5.211645629607382424e-28 3.672568381773789517e-21 6.136567355618997793e-25 8.376327212091044964e-24 1.342047871956311056e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.886417287653597948e-21 0.000000000000000000e+00 4.343799834267726630e-21 7.385622861490538036e-20 9.210500447858412372e+02 7.294619114251134976e-20 7.273526119307867494e-20 1.319373998018226367e-20 5.184033424316977477e-28 3.670704268314992083e-21 6.082360005208275978e-25 8.357156677491668700e-24 1.341971771447053788e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.889019345249883079e-21 0.000000000000000000e+00 4.347125402240564660e-21 7.420924440932460661e-20 9.221000542240523146e+02 7.241359211931252030e-20 7.280852652565973067e-20 1.187509616296770557e-20 5.156451015186511785e-28 3.668836858289759926e-21 6.028958204099180922e-25 8.337985795990195897e-24 1.341895669605690963e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.917394797057807240e-21 0.000000000000000000e+00 4.350454388823501491e-21 7.405942348732471811e-20 9.231500446839614824e+02 7.351238796527068318e-20 7.288180023287998697e-20 1.127005142816334962e-20 5.129368502634372746e-28 3.666934701659489761e-21 5.976385503405095725e-25 8.318815260991110411e-24 1.341819569184808865e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.944328853827204074e-21 0.000000000000000000e+00 4.353783315236967582e-21 7.403811400459042929e-20 9.241500446356100156e+02 7.146278988255097193e-20 7.295159433701352314e-20 1.286980427975749965e-20 5.103575400433231962e-28 3.665123107544184470e-21 5.927105903385483018e-25 8.300557443606921676e-24 1.341747091980312723e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.978738955458155252e-21 0.000000000000000000e+00 4.356953749997675037e-21 7.436838301428021589e-20 9.252000540423676966e+02 7.031883610145977205e-20 7.302488821854264822e-20 1.290983531955701199e-20 5.076586941877935961e-28 3.663226521506533089e-21 5.876213036078224468e-25 8.281386562679720475e-24 1.341671214470370990e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.951291610536585087e-21 0.000000000000000000e+00 4.360282736480891579e-21 7.444622028110948718e-20 9.262500445344119271e+02 7.297693563525347573e-20 7.309819039268020087e-20 1.263605306377646175e-20 5.049886152733168121e-28 3.661338049398539525e-21 5.826215486668245026e-25 8.262216027093919311e-24 1.341595661562365582e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.992026561154593618e-21 0.000000000000000000e+00 4.363611662996239364e-21 7.447290748478904314e-20 9.273000539199812238e+02 7.249776214260530658e-20 7.317150347001208734e-20 1.149040456789740504e-20 5.023184883134497749e-28 3.659449543309386113e-21 5.777134677026843326e-25 8.243045146553570362e-24 1.341520107339888349e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.943772133397013299e-21 0.000000000000000000e+00 4.366940649412279320e-21 7.435741790598145988e-20 9.283500444336716555e+02 7.279690716579448514e-20 7.324482478492845046e-20 1.310163301504097819e-20 4.996690297329451623e-28 3.657589849739211722e-21 5.728995956292489799e-25 8.223874610572556241e-24 1.341444554520385441e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.934995561842446297e-21 0.000000000000000000e+00 4.370269575996254910e-21 7.469503400837762387e-20 9.294000537981478374e+02 7.166077807632772121e-20 7.331815694295198684e-20 1.196210322737604041e-20 4.970422021819531084e-28 3.655739113809019906e-21 5.681821518607634508e-25 8.204703730417322752e-24 1.341369000389502916e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.956802013094802195e-21 0.000000000000000000e+00 4.373598562345419957e-21 7.457666431643591168e-20 9.304500443333861313e+02 7.482318347204219968e-20 7.339149728397164615e-20 1.231404470181038495e-20 4.944154217364085474e-28 3.653889922416574443e-21 5.635637293186795016e-25 8.185533194042892712e-24 1.341289222055220143e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.941424581372679152e-21 0.000000000000000000e+00 4.376927488997712645e-21 7.470546886926114409e-20 9.315000536768636721e+02 7.176364625508099305e-20 7.346484840846463393e-20 1.336609456367948240e-20 4.918214380636798200e-28 3.652052406065488485e-21 5.590466145487955062e-25 8.166362314271046705e-24 1.341176707312414161e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.967318256550506071e-21 0.000000000000000000e+00 4.380264512708469442e-21 7.495908510073848714e-20 9.326000536135520633e+02 7.262320475636446240e-20 7.354170188140189364e-20 1.314926985558868204e-20 4.891183665469028008e-28 3.650127406176283596e-21 5.544258880559308230e-25 8.146278715333300865e-24 1.341058835827915386e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.971052684525674310e-21 0.000000000000000000e+00 4.383771265111278634e-21 7.499634493399557572e-20 9.336500441814374653e+02 7.407405472674912378e-20 7.361507099606528095e-20 1.276281020314175650e-20 4.865381849466385522e-28 3.648271349676004160e-21 5.501242122615199027e-25 8.127108178362805558e-24 1.340964896165974234e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.015266775301574766e-21 0.000000000000000000e+00 4.387118589801081479e-21 7.500343180368820313e-20 9.347000534930978120e+02 6.993694813909998285e-20 7.368845080419361263e-20 1.108296971794405455e-20 4.840131137913282677e-28 3.646396333048039392e-21 5.459314629277947358e-25 8.107937299171872697e-24 1.340889881837685790e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.023264062309120678e-21 0.000000000000000000e+00 4.390465974245231396e-21 7.480862633869137684e-20 9.357500440822859673e+02 7.255363002777895613e-20 7.376183865945726340e-20 1.176190498021665582e-20 4.814902695087737543e-28 3.644521349853060643e-21 5.418503199418403529e-25 8.088766761812435697e-24 1.340814868892062138e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.984583436740834357e-21 0.000000000000000000e+00 4.393813299002946593e-21 7.498296453787845548e-20 9.368000533731839141e+02 7.360865256370716765e-20 7.383523714967764757e-20 1.133486398463961131e-20 4.789727547076991616e-28 3.642682825078789008e-21 5.378831766293667383e-25 8.069595883000579192e-24 1.340740075817664435e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.048072875601479277e-21 0.000000000000000000e+00 4.397160683380906963e-21 7.499209254549835765e-20 9.378500439835784164e+02 7.245434735091896459e-20 7.390864363394772803e-20 1.322864427483533939e-20 4.764812515643902574e-28 3.640851880598030564e-21 5.340327163736758423e-25 8.050425345253960801e-24 1.340665329861885923e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.286678461094444830e-21 0.000000000000000000e+00 4.400508008206226815e-21 7.538371581604751027e-20 9.389000532538061634e+02 7.350150029111555218e-20 7.398206069510512999e-20 1.332860294761159163e-20 4.739897041435109309e-28 3.639020903578772226e-21 5.303013424519629391e-25 8.031254466819496758e-24 1.340590582622895459e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.135531655649218352e-21 0.000000000000000000e+00 4.403855392518291793e-21 7.546696087255837892e-20 9.400000531914879502e+02 7.362389479786876468e-20 7.405898303847444372e-20 1.098789589147166443e-20 4.714028597187197338e-28 3.637102754221248791e-21 5.265228782792265990e-25 8.011170867863613040e-24 1.340512276735768258e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.128380728616313719e-21 0.000000000000000000e+00 4.407362144924267484e-21 7.516451280983256512e-20 9.410500438340142182e+02 7.394755159213636709e-20 7.413241769745773121e-20 1.136121072143412490e-20 4.689683051441841134e-28 3.635271809684458575e-21 5.242774154855597926e-25 7.993886929391524961e-24 1.340437530915263943e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.030749542961061076e-21 0.000000000000000000e+00 4.410709469852022735e-21 7.528840748500689674e-20 9.421000530729207867e+02 7.495749510995332918e-20 7.420586284577052140e-20 1.139972135701034777e-20 4.665337074512615764e-28 3.633447611287168456e-21 5.224384909009108745e-25 7.977197506035923960e-24 1.340363060491909259e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.018790718086354515e-21 0.000000000000000000e+00 4.414056224162631487e-21 7.536616811301327006e-20 9.432000530110248064e+02 7.488057814010388011e-20 7.428281452639914930e-20 1.287173781179104844e-20 4.640069059613081903e-28 3.631543017754762412e-21 5.205150860643136043e-25 7.959713503059653632e-24 1.340285308047139075e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.083490177754325070e-21 0.000000000000000000e+00 4.417560380493730677e-21 7.568107724309471318e-20 9.442500436854637655e+02 7.695731069029176240e-20 7.435627710573500662e-20 1.310344900791429004e-20 4.616089542859003436e-28 3.629725012700080262e-21 5.186820874462643044e-25 7.943024374777895006e-24 1.340211090972164103e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.539118902681167498e-21 0.000000000000000000e+00 4.420905227472333153e-21 7.581290931867950923e-20 9.453000528932600446e+02 7.423506332647532335e-20 7.442975008764635877e-20 1.192054372801788004e-20 4.592109602843115735e-28 3.627906975555839260e-21 5.168519814414300611e-25 7.926334951916777458e-24 1.340136873664997964e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.952443788893423911e-21 0.000000000000000000e+00 4.424250133490740123e-21 7.571024105751150242e-20 9.464000528317822045e+02 7.481132874052605294e-20 7.450673084093451728e-20 1.204126472000334765e-20 4.567306555837357155e-28 3.626002382022709486e-21 5.149379156265129853e-25 7.908850948933861178e-24 1.340059122924507450e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.506769166144859596e-21 0.000000000000000000e+00 4.427754289823170913e-21 7.598112768468004380e-20 9.475000527704471551e+02 7.610462161328013445e-20 7.458372152749138955e-20 1.217042558951757842e-20 4.542565816476139151e-28 3.624101312780635014e-21 5.130271304891455248e-25 7.891366945948676195e-24 1.339981516071312122e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.906563123890025896e-21 0.000000000000000000e+00 4.431258446156056854e-21 7.595716498363597551e-20 9.485500434874272742e+02 7.744547992599459923e-20 7.465722122965033251e-20 1.313280266362507866e-20 4.519005065961463093e-28 3.622296065583020106e-21 5.112063093870623997e-25 7.874677816990743831e-24 1.339907820911923641e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.318979216088989052e-21 0.000000000000000000e+00 4.434603293270178593e-21 7.615383719419215242e-20 9.496000526537475253e+02 7.795909623938212942e-20 7.473073121948378982e-20 1.189847479513021712e-20 4.495968075556576981e-28 3.620490786665486468e-21 5.093885114671724995e-25 7.857988394788869964e-24 1.339834124493089824e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.174674602485905091e-21 0.000000000000000000e+00 4.437948199156459246e-21 7.601501400597818204e-20 9.507000525928248180e+02 7.575751961746464448e-20 7.480775062853785375e-20 1.318600786182304950e-20 4.471834297628995368e-28 3.618599558700055643e-21 5.074874810939430121e-25 7.840504391797130130e-24 1.339734461482322418e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.258567102136713639e-21 0.000000000000000000e+00 4.441452355490658732e-21 7.630741420823812499e-20 9.518000525320431962e+02 7.795155705593838441e-20 7.488477985143068226e-20 1.317892445657144244e-20 4.447796854823947756e-28 3.616708330734381820e-21 5.055898780214368450e-25 7.823020388803149510e-24 1.339618660028648471e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.806089454907257632e-21 0.000000000000000000e+00 4.444956511825308103e-21 7.635793002248816517e-20 9.528500432911781672e+02 7.766480982044718521e-20 7.495831622989501345e-20 1.336429900916449595e-20 4.425041202251389928e-28 3.614903083464290256e-21 5.037817781768300316e-25 7.806331259175183897e-24 1.339508123279803712e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.534797430628933894e-21 0.000000000000000000e+00 4.448302475186126199e-21 7.644931468182956486e-20 9.539000524163944874e+02 7.623711605618087024e-20 7.503186278287283584e-20 1.229322357072591726e-20 4.402285151644693735e-28 3.613103756349533935e-21 5.019768389598415048e-25 7.789641837626638035e-24 1.339432566194432557e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.388837127228940095e-21 0.000000000000000000e+00 4.451659100686712599e-21 7.633514212690871236e-20 9.550000523560195234e+02 7.677342398192143470e-20 7.510892038352996635e-20 1.332327523248165247e-20 4.378638883071583215e-28 3.611219141068358085e-21 5.000894283295857859e-25 7.772157834626193665e-24 1.339355631195021593e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.094276064444474856e-21 0.000000000000000000e+00 4.455175534743634410e-21 7.657099682880218091e-20 9.561000522957835983e+02 7.657569835597906955e-20 7.518598768044468462e-20 1.477854994025021687e-20 4.355172217689949180e-28 3.609336496080369940e-21 4.982055993666184265e-25 7.754673831623537897e-24 1.339278776654585754e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.051780147967866732e-21 0.000000000000000000e+00 4.458691968801000841e-21 7.691132956808992623e-20 9.572000522356859165e+02 7.668105131898458524e-20 7.526306464383089518e-20 1.205136380733936262e-20 4.331705552305366365e-28 3.607458447402487640e-21 4.963253928541622521e-25 7.737189828618685423e-24 1.339202109757356756e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.044465026185293800e-21 0.000000000000000000e+00 4.462208402858809633e-21 7.650981387492381896e-20 9.582500430472206290e+02 7.730407474672549963e-20 7.533664645906245631e-20 1.291754017861943216e-20 4.309633765544848076e-28 3.605665780163281693e-21 4.945340830048628026e-25 7.720500698157849737e-24 1.339128928391857221e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.034787175856036928e-21 0.000000000000000000e+00 4.465564969814980592e-21 7.672299850450440495e-20 9.593000521213372167e+02 7.706957170064686597e-20 7.541023830911336995e-20 1.248987030577359947e-20 4.287653575593340215e-28 3.603873081744058373e-21 4.927461167070545419e-25 7.703811277421511696e-24 1.339055745789021236e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.036938817223885295e-21 0.000000000000000000e+00 4.468921595152214278e-21 7.672467784726535083e-20 9.604000520616395988e+02 7.677848683286833346e-20 7.548734322487853568e-20 1.271658047391700634e-20 4.264626910176344425e-28 3.601995033065493722e-21 4.908766851927065251e-25 7.686327274410299799e-24 1.338979079005149577e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.130407187161284329e-21 0.000000000000000000e+00 4.472438029211301256e-21 7.684152425411417844e-20 9.615000520020786325e+02 7.642682330945471643e-20 7.556445769180711976e-20 1.275470080129112153e-20 4.242032044990439320e-28 3.600116984386695102e-21 4.890110408160972473e-25 7.668843271396916175e-24 1.338902412260257876e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.035659641646161359e-21 0.000000000000000000e+00 4.475954463270825330e-21 7.691991041093113704e-20 9.626000519426539768e+02 7.517078275323724538e-20 7.564158168068777237e-20 1.118561101804268602e-20 4.219449264753463086e-28 3.598289533105626797e-21 4.871492270882469908e-25 7.651359268381366703e-24 1.338826271240933922e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.029303652944226456e-21 0.000000000000000000e+00 4.479470897330784995e-21 7.675121702796723860e-20 9.637000518833648357e+02 7.491874496439750947e-20 7.571871516242441056e-20 1.135582221643451535e-20 4.196949447108276023e-28 3.596462543584722998e-21 4.852912880978657569e-25 7.633875265363661668e-24 1.338750135058116399e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.045835281785603711e-21 0.000000000000000000e+00 4.482987331391178746e-21 7.685297434257112269e-20 9.648000518242109820e+02 7.824566877328070463e-20 7.579585810803589332e-20 1.278523656719741663e-20 4.174731626520888371e-28 3.594621711439919200e-21 4.834372685189622962e-25 7.616391262343808417e-24 1.338673998914308173e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.029643234797899314e-21 0.000000000000000000e+00 4.486523056643287022e-21 7.715241680756031580e-20 9.659000517651917335e+02 7.482827221225916281e-20 7.587301048865540764e-20 1.260933574253412578e-20 4.152513805930782425e-28 3.592756659636872356e-21 4.815872136185198110e-25 7.598907259321814298e-24 1.338597862809515827e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.050294684251704528e-21 0.000000000000000000e+00 4.490060572467366809e-21 7.720021899394951783e-20 9.670000517063068628e+02 7.666213725370012510e-20 7.595017227552987870e-20 1.494878330332946885e-20 4.130535821586049678e-28 3.590891607833597561e-21 4.797411692642333719e-25 7.581423256297683717e-24 1.338521726743746132e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.007620688208605840e-21 0.000000000000000000e+00 4.493598088291878425e-21 7.769053480042544700e-20 9.681000516475558015e+02 7.698200606410836954e-20 7.602734344001947639e-20 1.233987249939776374e-20 4.108825296429820328e-28 3.589063832333928409e-21 4.778991819323109751e-25 7.563939253271428430e-24 1.338418139209258347e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.019363542970776905e-21 0.000000000000000000e+00 4.497135604116820367e-21 7.730745752153538528e-20 9.691500425630698601e+02 7.755400636145361158e-20 7.610101491250180406e-20 1.243066823531660510e-20 4.088101791518357968e-28 3.587331888555760714e-21 4.761447642233659816e-25 7.547250121157887359e-24 1.338309881860717642e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.021302300037245580e-21 0.000000000000000000e+00 4.500512294733239096e-21 7.739463122593722191e-20 9.702000515357644872e+02 7.817056352689778844e-20 7.617469614578177454e-20 1.063005438110055573e-20 4.067511124088012391e-28 3.585599913221564909e-21 4.743940973532455364e-25 7.530560702033606108e-24 1.338201624456423335e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.017670716978417502e-21 0.000000000000000000e+00 4.503889043420171120e-21 7.719858230161141873e-20 9.713000514774001886e+02 7.670438437170602564e-20 7.625189442880775147e-20 1.262722724999032758e-20 4.046016043261297041e-28 3.583747679642865603e-21 4.725641822997216173e-25 7.513076699001201517e-24 1.338126011734674534e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.005717074674473704e-21 0.000000000000000000e+00 4.507426559246357392e-21 7.757437325978983094e-20 9.724000514191677667e+02 7.722523657015473408e-20 7.632910197856944496e-20 1.195381489336765658e-20 4.024520962432002854e-28 3.581895446063944364e-21 4.707385119363199807e-25 7.495592695966701606e-24 1.338050399937070993e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.038918983228790448e-21 0.000000000000000000e+00 4.510964075072967219e-21 7.754501747435350165e-20 9.735000513610669941e+02 7.423593806055982283e-20 7.640631876697514455e-20 1.154102408283035974e-20 4.003404000842012185e-28 3.580058819680437897e-21 4.689171358415619778e-25 7.478108692930109316e-24 1.337974880249654634e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.012442642499878626e-21 0.000000000000000000e+00 4.514501590900000600e-21 7.755761325469101205e-20 9.746000513030974162e+02 7.723809128888486595e-20 7.648354476604319464e-20 1.284587838544715134e-20 3.982356133098767567e-28 3.578250600597647890e-21 4.671001042497294114e-25 7.460624689891430523e-24 1.337899527695241383e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.025449843466522382e-21 0.000000000000000000e+00 4.518039106727455278e-21 7.783899500882745799e-20 9.757500610641367302e+02 7.657783916433835155e-20 7.656429154537173306e-20 1.217414119563256365e-20 3.960399766353658431e-28 3.576360173593199963e-21 4.652051646111347106e-25 7.442345803331304542e-24 1.337820749385537512e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.043209818300926102e-21 0.000000000000000000e+00 4.521737137502767347e-21 7.781123221289091850e-20 9.769000511823101078e+02 7.808201151641635547e-20 7.664504695024292057e-20 1.244702046020504712e-20 3.938823404527344044e-28 3.574474660179150908e-21 4.633151203131419320e-25 7.424067228985672544e-24 1.337742175843085845e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.066421616901294650e-21 0.000000000000000000e+00 4.525434959747843159e-21 7.793484793085785468e-20 9.780000511247430950e+02 7.746105223545569891e-20 7.672230124289487294e-20 1.272900964092489211e-20 3.918184969125344310e-28 3.572672612491888239e-21 4.615118419510958795e-25 7.406583225940596124e-24 1.337667080527074007e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.034307911433132325e-21 0.000000000000000000e+00 4.528972037321319703e-21 7.805518051061913262e-20 9.791000510673054578e+02 7.767178495031210587e-20 7.679956463287420507e-20 9.957121158759975977e-21 3.897683344616803016e-28 3.570871345196235805e-21 4.597131205978840455e-25 7.389099222893464057e-24 1.337592017758809348e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.024257536026791443e-21 0.000000000000000000e+00 4.532509114895213031e-21 7.772739215662719783e-20 9.802000510099967414e+02 7.746943158092859569e-20 7.687683709275175047e-20 1.355325834014057190e-20 3.877411917101492166e-28 3.569075426922454372e-21 4.579190099537691422e-25 7.371615219844282222e-24 1.337517177897674008e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.056990909710385923e-21 0.000000000000000000e+00 4.536046192469520132e-21 7.834658325451712986e-20 9.813000509528164912e+02 7.733971387639889045e-20 7.695411859520519565e-20 1.276109388141158497e-20 3.857140489583813682e-28 3.567279508648462291e-21 4.561295644251576749e-25 7.354131216793057966e-24 1.337442338068011823e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.074888159338529788e-21 0.000000000000000000e+00 4.539583270044240255e-21 7.829022243336004499e-20 9.824000508957642523e+02 7.910174898439231085e-20 7.703140911301880328e-20 1.326635483345973729e-20 3.837032711647092720e-28 3.565466581840392765e-21 4.543448391329880123e-25 7.336647213739798635e-24 1.337350489755230910e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.125537808425739832e-21 0.000000000000000000e+00 4.543120347619372647e-21 7.845217780215462313e-20 9.835000508388395701e+02 7.655795359731773858e-20 7.710870861908266585e-20 1.426043173809437016e-20 3.817046998395634803e-28 3.563633248601933559e-21 4.525648899211412322e-25 7.319163210684513046e-24 1.337238235066480814e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.231291778537915005e-21 0.000000000000000000e+00 4.546657425194915052e-21 7.870650507018082392e-20 9.846000507820422172e+02 7.869673105249662354e-20 7.718601708639241684e-20 1.303410240339855025e-20 3.797061285141863958e-28 3.561799915363262952e-21 4.507897733648689572e-25 7.301679207627202668e-24 1.337125980408673866e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.079018760813702845e-21 0.000000000000000000e+00 4.550194502770866716e-21 7.856352883945531946e-20 9.857000507253715114e+02 7.868293810454124911e-20 7.726333448831774143e-20 1.273662511295645318e-20 3.777405549683081994e-28 3.560005323148046031e-21 4.493499443816526336e-25 7.286219564511439155e-24 1.337043374491466517e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.068615801191479758e-21 0.000000000000000000e+00 4.553731580347225384e-21 7.859044933030896995e-20 9.868500603772930617e+02 7.840022119962766353e-20 7.734417652398349929e-20 1.151987491150357944e-20 3.756957636130210420e-28 3.558140442631416357e-21 4.478858581930585141e-25 7.270306675727131100e-24 1.336965660948931437e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.031550471024672043e-21 0.000000000000000000e+00 4.557437345647825517e-21 7.848081031190805026e-20 9.880000506072861981e+02 8.100220716898209013e-20 7.742502689949257308e-20 1.275779030921751982e-20 3.736522338383223151e-28 3.556275593609806449e-21 4.464220074526681538e-25 7.254394055687513895e-24 1.336887948753315212e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.076205281669821923e-21 0.000000000000000000e+00 4.561150680034270142e-21 7.875339711233297081e-20 9.891000505510047560e+02 8.056881934003949325e-20 7.750237174774589233e-20 1.373498927646593909e-20 3.717233307112105680e-28 3.554491809917289591e-21 4.450219896693790221e-25 7.239173160160341641e-24 1.336813614753344685e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.050204397679487372e-21 0.000000000000000000e+00 4.564702595093689310e-21 7.899259046816192124e-20 9.902000504948482558e+02 8.429216975274548743e-20 7.757972542138244245e-20 1.315030357976715649e-20 3.697944275838806667e-28 3.552708026224570359e-21 4.436221684302747761e-25 7.223952264631439941e-24 1.336739280784900540e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.009848822051614542e-21 0.000000000000000000e+00 4.568254510153510966e-21 7.896759511663602688e-20 9.913000504388164700e+02 4.467047908718278326e-18 7.765708789402962211e-20 1.466785312685222016e-20 3.678750673242001398e-28 3.550948242596497045e-21 4.422225456017935913e-25 7.208731369100813204e-24 1.336665191746345234e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.053857347782967356e-21 0.000000000000000000e+00 4.571806425213735864e-21 7.931199552173668130e-20 9.924500600366079652e+02 1.033887955898272594e-17 7.773797690146337010e-20 1.217038978368349658e-20 3.659023585526205850e-28 3.549134469069779124e-21 4.407595054652958590e-25 7.192818481065512516e-24 1.336587999873751240e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.034842685608821235e-21 0.000000000000000000e+00 4.575519822139070179e-21 7.896733480927587405e-20 9.936000503220600422e+02 7.854267890474260424e-19 7.781887410891037282e-20 1.191122783799299999e-20 3.639296829091370388e-28 3.547320726002120243e-21 4.392967110072282021e-25 7.176905860258500273e-24 1.336510809331947001e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.068183343358045354e-21 0.000000000000000000e+00 4.579233156704591683e-21 7.900890733769507655e-20 9.947000502664106989e+02 2.579980855840209080e-17 7.789626361285444507e-20 1.122115508546433169e-20 3.620556714085000274e-28 3.545553610309137142e-21 4.378977135016663891e-25 7.161684964722580872e-24 1.336404757894985460e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.063355217149279470e-21 0.000000000000000000e+00 4.582785071766051884e-21 7.898408225748891794e-20 9.958000502108844785e+02 2.325536816590939581e-17 7.797366180897770452e-20 1.283965878975780375e-20 3.601955432972476631e-28 3.543781798318038296e-21 4.364989222901693889e-25 7.146464069184958473e-24 1.336294010196122239e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.039561053458265662e-21 0.000000000000000000e+00 4.586336986827909309e-21 7.930552511944508250e-20 9.969500597656167429e+02 1.853360770957192189e-17 7.805458804714854572e-20 1.194807747824901802e-20 3.582508476527610165e-28 3.541930673285965809e-21 4.350367601716344950e-25 7.130551181745476200e-24 1.336185999334274780e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.053387048469317741e-21 0.000000000000000000e+00 4.590050383614204271e-21 7.924643665541928193e-20 9.981000500951796539e+02 8.291180654913352705e-18 7.813552237499842625e-20 1.476562257191743578e-20 3.563215754035599527e-28 3.540084534964259805e-21 4.335748524471439194e-25 7.114638560328094393e-24 1.336109067052495787e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.044134276613999306e-21 0.000000000000000000e+00 4.593772166319672127e-21 7.979893733452925316e-20 9.992000500400308738e+02 7.097855236239294182e-18 7.821294727481068454e-20 1.149696761162538683e-20 3.544823471999494958e-28 3.538318648765168032e-21 4.321767115631583839e-25 7.099417664785248391e-24 1.336035479069723321e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.059996268365545790e-21 0.000000000000000000e+00 4.597347181366482749e-21 7.933630508281533661e-20 1.000350059562484716e+03 8.694149634253775667e-20 7.829390134362472413e-20 1.206482492884649139e-20 3.525595016961677484e-28 3.536472479632131594e-21 4.307152361298528830e-25 7.083504777792408420e-24 1.335958548570063919e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.072182353886308124e-21 0.000000000000000000e+00 4.601084728232727723e-21 7.950091034991431516e-20 1.001500049925111057e+03 8.098525983161693498e-20 7.837486341993040379e-20 1.338216563935932735e-20 3.507145450574165045e-28 3.534626341257346660e-21 4.292540219873423203e-25 7.067592155917521273e-24 1.335881626216202704e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.063962526425958760e-21 0.000000000000000000e+00 4.604822212829268581e-21 7.979080172860649780e-20 1.002600049870335965e+03 8.072474486752901892e-20 7.845231477931102472e-20 1.375313938878184295e-20 3.489531701451250029e-28 3.532860455057654539e-21 4.278565512035554838e-25 7.052371260369506035e-24 1.335808047699570013e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.091056227419867803e-21 0.000000000000000000e+00 4.608397227877294194e-21 7.993104545134234378e-20 1.003750059360728983e+03 3.326567876531813966e-18 7.853329642456579248e-20 1.277325448730887120e-20 3.471074516482575505e-28 3.531054907001524562e-21 4.263957833989129741e-25 7.036458373820297632e-24 1.335696356249992108e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.077861233768596533e-21 0.000000000000000000e+00 4.612134774639341092e-21 7.984755586532356324e-20 1.004900049756193425e+03 1.507124762769839697e-18 7.861428599612102443e-20 1.295359072899837249e-20 3.452333382682941859e-28 3.529253255381963348e-21 4.249352840648579808e-25 7.020545751491023143e-24 1.335581357327735558e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.078515461063222528e-21 0.000000000000000000e+00 4.615872259342605552e-21 7.995639102150731903e-20 1.006000049701788043e+03 8.540384516985803502e-20 7.869176357383401762e-20 1.238489983724369989e-20 3.434406931956669684e-28 3.527519920477138779e-21 4.235385039536518539e-25 7.005324855937891566e-24 1.335481359091909197e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.094788790512914720e-21 0.000000000000000000e+00 4.619447274391832614e-21 7.994325090726125538e-20 1.007150059160335218e+03 8.219897012196362266e-20 7.877277254432837647e-20 1.146037214476822240e-20 3.416001580056789478e-28 3.525679905343463579e-21 4.220784655708325963e-25 6.989411969829340730e-24 1.335404691872890031e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.096572217280777565e-21 0.000000000000000000e+00 4.623184821050380338e-21 7.988533153789591022e-20 1.008300049588414936e+03 1.746967722577394697e-19 7.885378936091387474e-20 1.209108145852757054e-20 3.398119228900149389e-28 3.523839920658536170e-21 4.206187031356667710e-25 6.973499347048763104e-24 1.335328025922576463e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.072676149942227343e-21 0.000000000000000000e+00 4.626922305859644672e-21 8.005725884445997302e-20 1.009450059025540327e+03 1.694179813350705810e-17 7.893481667518607556e-20 1.347104101561213062e-20 3.380236582152848929e-28 3.522062813735471312e-21 4.191591709926488951e-25 6.957586461236627863e-24 1.335252971733520026e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.103903849298797383e-21 0.000000000000000000e+00 4.630660174482203354e-21 8.035819396858597914e-20 1.010600049475557967e+03 8.322110411915928570e-20 7.901585178183975558e-20 1.393971958335570929e-20 3.362511741787075211e-28 3.520319279827379440e-21 4.176999200314632487e-25 6.941673838152492044e-24 1.335178778876979440e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.097738150780602658e-21 0.000000000000000000e+00 4.634399630616654420e-21 8.051751148057246206e-20 1.011700049421764220e+03 8.164613049007387496e-20 7.909337278039886322e-20 1.207799814040747129e-20 3.345654242611464702e-28 3.518651537973453950e-21 4.163043462962007668e-25 6.926452942590896908e-24 1.335107811210949696e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.114231192580935677e-21 0.000000000000000000e+00 4.637976531230631809e-21 8.029328981145445281e-20 1.012850058827399607e+03 8.471322829922164140e-20 7.917442700539543746e-20 1.299697218527858664e-20 3.328030348470102281e-28 3.516819905876160270e-21 4.148455821362765776e-25 6.910540057214495382e-24 1.335031358942762446e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.094376393091853932e-21 0.000000000000000000e+00 4.641716049003595802e-21 8.051572672258931778e-20 1.014000049309663495e+03 7.731568190846993261e-20 7.925548894417857691e-20 1.397398311560476790e-20 3.310170844308730474e-28 3.514979921104538177e-21 4.133871071679397121e-25 6.894627433684162479e-24 1.334954692988880641e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.098720190231574860e-21 0.000000000000000000e+00 4.645455505242902469e-21 8.075905083115722606e-20 1.015150058694115728e+03 7.812768334226212955e-20 7.933656123530886196e-20 1.294652155342378245e-20 3.292245536742043015e-28 3.513151574712552277e-21 4.119288762357781417e-25 6.878714548600874878e-24 1.334866357163640469e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.110113217556918269e-21 0.000000000000000000e+00 4.649195022946984374e-21 8.066792632285392710e-20 1.016300049198070269e+03 7.888873271763783872e-20 7.941764118759506630e-20 1.300824936707538318e-20 3.274391768178705772e-28 3.511349922923023232e-21 4.104709401051616498e-25 6.862801924770404472e-24 1.334751358230680714e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.095377255508279646e-21 0.000000000000000000e+00 4.652934479256822959e-21 8.075715838088805264e-20 1.017450058561434616e+03 7.996383128680196625e-20 7.949873143437103717e-20 1.116675235209000758e-20 3.257285378898660739e-28 3.509548241587085952e-21 4.090132538266898834e-25 6.846889039978914241e-24 1.334636357411802208e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.119599590396466006e-21 0.000000000000000000e+00 4.656673996892332729e-21 8.056214621147224685e-20 1.018600049086981016e+03 8.018675725016376400e-20 7.957982929010018693e-20 1.318124114901223894e-20 3.240179269831157680e-28 3.507787022351996346e-21 4.075558681205991990e-25 6.830976415849674313e-24 1.334549747286291710e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.121612851493386222e-21 0.000000000000000000e+00 4.660413453272382746e-21 8.094593200445871524e-20 1.019750058429351952e+03 7.868395298186567938e-20 7.966093738290868437e-20 1.194312930844912895e-20 3.223142892549260263e-28 3.506043459800660335e-21 4.060987382461073026e-25 6.815063531348673716e-24 1.334475553210970934e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.114617200123098161e-21 0.000000000000000000e+00 4.664152970839628080e-21 8.083335733467258397e-20 1.020950058360675484e+03 8.098026280300047573e-20 7.974558069232156664e-20 1.176278870823545244e-20 3.205532893557087314e-28 3.504224105066072489e-21 4.045785687874668993e-25 6.798458918147018203e-24 1.334398133939666779e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.139748145991586149e-21 0.000000000000000000e+00 4.668055044204201778e-21 8.089146954906465205e-20 1.022100048918891389e+03 7.814717699255235469e-20 7.982670558320555963e-20 1.404560982299330365e-20 3.188656782115269336e-28 3.502480570993938783e-21 4.031220436624192003e-25 6.782546293565722821e-24 1.334323941076242875e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.119381769133525687e-21 0.000000000000000000e+00 4.671812740927332804e-21 8.133379551681331305e-20 1.023250058229495835e+03 7.756562897230463659e-20 7.990784062465314201e-20 1.275088663643616886e-20 3.172211305293368128e-28 3.500737008490764562e-21 4.016657837949053709e-25 6.766633409504280704e-24 1.334249747002997176e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.122494551595598514e-21 0.000000000000000000e+00 4.675570668685001904e-21 8.120033537216137242e-20 1.024400048809057807e+03 7.891670010459399439e-20 7.998898314528526122e-20 1.215080269737919122e-20 3.156097497899748508e-28 3.498973256865809806e-21 4.002098398050973976e-25 6.750720784627617387e-24 1.334161358872401587e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.134660574522602241e-21 0.000000000000000000e+00 4.679328535234553767e-21 8.118881997776334112e-20 1.025550058098904856e+03 7.920441846243393538e-20 8.007013576017886344e-20 1.182739587903809026e-20 3.139983428335346793e-28 3.497171575645049155e-21 3.987541674907487336e-25 6.734807900853399967e-24 1.334046358060978725e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.133425053936646090e-21 0.000000000000000000e+00 4.683086462924393269e-21 8.122113961003268691e-20 1.026700048699716490e+03 7.995667219058931937e-20 8.015129580352891055e-20 1.229111443855616446e-20 3.123689306637787457e-28 3.495369923703777143e-21 3.972988174381009047e-25 6.718895275682699963e-24 1.333931359118477717e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.137623303667077946e-21 0.000000000000000000e+00 4.686844329543383182e-21 8.137020297361518940e-20 1.027850057968898000e+03 7.702736698084544707e-20 8.023246588527045280e-20 1.259045629216970638e-20 3.107316049667814612e-28 3.493611202434251404e-21 3.958437456637742645e-25 6.702982392194434769e-24 1.333846521625597566e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.135592938692092346e-21 0.000000000000000000e+00 4.690602257165693260e-21 8.149592858021754807e-20 1.029050057901298942e+03 8.092454765134205441e-20 8.031717368278527681e-20 1.428339811328661499e-20 3.090231050630254903e-28 3.491791847698030279e-21 3.943257477146615549e-25 6.686377778977871049e-24 1.333769102354298866e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.160536844175068675e-21 0.000000000000000000e+00 4.694523541118429391e-21 8.185879909737269207e-20 1.030200048534264170e+03 8.108626582241218511e-20 8.039836018767417770e-20 1.308018072035769494e-20 3.074078068700266087e-28 3.490048313512566880e-21 3.928713268874725024e-25 6.670465153362256718e-24 1.333694909486123895e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.137982324597406907e-21 0.000000000000000000e+00 4.698281407842489315e-21 8.173657353836572035e-20 1.031350057772174068e+03 7.926061014110093055e-20 8.047955664676807122e-20 1.323936307467854962e-20 3.057934814023106217e-28 3.488304751119607010e-21 3.914319756773961537e-25 6.654672087502400912e-24 1.333620715417639607e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.169782653490427563e-21 0.000000000000000000e+00 4.702039335362611506e-21 8.184340735424163744e-20 1.032550057705032941e+03 8.002422398694533993e-20 8.056429188569459260e-20 1.281828243236972199e-20 3.041244680248830633e-28 3.486485396382691497e-21 3.901799469475345802e-25 6.640216754694010459e-24 1.333543296146337897e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.190598355548899425e-21 0.000000000000000000e+00 4.705960619316844747e-21 8.186069531321484459e-20 1.033700048369932347e+03 8.066079128581930942e-20 8.064550460937203429e-20 1.193116007466711614e-20 3.025813896417997768e-28 3.484741862148812025e-21 3.889801308686951481e-25 6.626363839095873595e-24 1.333452972700055566e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.168105072369785246e-21 0.000000000000000000e+00 4.709739357033446186e-21 8.180580722494315764e-20 1.034850057576780728e+03 7.895513380206362433e-20 8.072672720401732921e-20 1.317261945207296955e-20 3.010382863787922967e-28 3.482998299802944904e-21 3.877803301363180629e-25 6.612510700139355168e-24 1.333341681600379775e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.192932624938529452e-21 0.000000000000000000e+00 4.713523796412109388e-21 8.207705912555406681e-20 1.036050057510092984e+03 7.809023865472291393e-20 8.081148963260239119e-20 1.357686765968011159e-20 2.994187966424982090e-28 3.481178945065342526e-21 3.865284115837202512e-25 6.598055367325503074e-24 1.333225552693436427e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.173473764786248780e-21 0.000000000000000000e+00 4.717472744798762505e-21 8.222560317703992603e-20 1.037250057443559172e+03 8.044132701904075500e-20 8.089626132599417034e-20 1.336815537249263446e-20 2.977837967331505415e-28 3.479359590327506930e-21 3.852765315280795580e-25 6.583600034509796638e-24 1.333140070769431995e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.195943732433250125e-21 0.000000000000000000e+00 4.721421693185921931e-21 8.227576680184594268e-20 1.038400048151000419e+03 7.929690481279317379e-20 8.097750888030473352e-20 1.307902431270205546e-20 2.962169343942618253e-28 3.477616056029128365e-21 3.840768592415741925e-25 6.569747118399196400e-24 1.333065877896523638e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.186795093336142418e-21 0.000000000000000000e+00 4.725206071686911583e-21 8.230900302030123662e-20 1.039550057316465427e+03 8.069080735171498439e-20 8.105876619534045232e-20 1.252345030525502969e-20 2.946946525876358833e-28 3.475872493746004430e-21 3.828772037371081038e-25 6.555893979941186025e-24 1.332986843279146004e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.197050557077487878e-21 0.000000000000000000e+00 4.728990510929390473e-21 8.230311935048093178e-20 1.040750057250378859e+03 7.929337759127636889e-20 8.114356474532980029e-20 1.258694931841767724e-20 2.931310163101123155e-28 3.474053139007490245e-21 3.816254381326933582e-25 6.541438647120092152e-24 1.332870714372207922e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.231160633462278404e-21 0.000000000000000000e+00 4.732939459318021430e-21 8.239779208315406651e-20 1.041950057184444177e+03 7.855685429642431067e-20 8.122837244684368925e-20 1.351786552628285321e-20 2.915673800323908172e-28 3.472233784268745851e-21 3.803737125281807474e-25 6.526983314297168180e-24 1.332754585465275858e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.226467074241586584e-21 0.000000000000000000e+00 4.736888407707152677e-21 8.262845796275002152e-20 1.043150057118661607e+03 8.111597846091838064e-20 8.131318927124771779e-20 1.302622274348753767e-20 2.900241084985906979e-28 3.470465542891923901e-21 3.791220273197677953e-25 6.512527981472411907e-24 1.332660736719026095e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.218618092264184197e-21 0.000000000000000000e+00 4.740837356096784215e-21 8.263275638610798134e-20 1.044300047878960868e+03 8.239675069398032841e-20 8.139447994681623052e-20 1.226514953921253776e-20 2.885479385408248000e-28 3.468812431173993640e-21 3.779225435111257344e-25 6.498675064725078705e-24 1.332588862370145612e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.217530264874030827e-21 0.000000000000000000e+00 4.744621734771718444e-21 8.259641451405590897e-20 1.045450056993000089e+03 8.192757145389060568e-20 8.147578024712824291e-20 1.362614495570922018e-20 2.870707381953762289e-28 3.467159293072562497e-21 3.767230783857245802e-25 6.484821926886549445e-24 1.332516986874165456e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.240628460880084596e-21 0.000000000000000000e+00 4.748408910975356395e-21 8.289041253678446600e-20 1.046650056927656578e+03 8.204289959092217423e-20 8.156062351749312051e-20 1.467659361037725113e-20 2.855062382805677839e-28 3.465359591109681866e-21 3.754715133116891395e-25 6.470366594056504182e-24 1.332440071519715200e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.248147050410786242e-21 0.000000000000000000e+00 4.752362660749614376e-21 8.315321565840557635e-20 1.047850056862462907e+03 8.212635187697551527e-20 8.164547579971065693e-20 1.210186301148061784e-20 2.839417383655639642e-28 3.463540236369814264e-21 3.742199902367701363e-25 6.455911261224654535e-24 1.332362652248428349e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.255827852858492526e-21 0.000000000000000000e+00 4.756316410524366629e-21 8.282169468647173446e-20 1.049050056797418392e+03 8.248201627626541540e-20 8.173033706571258992e-20 1.387159944429567737e-20 2.824026564308562625e-28 3.461732729078791358e-21 3.729685095837631342e-25 6.441455928391007117e-24 1.332277922856484196e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.244579024626631809e-21 0.000000000000000000e+00 4.760270160299610897e-21 8.318182092649108584e-20 1.050250056732522580e+03 8.128036881479823810e-20 8.181520728754414261e-20 1.311320236879680925e-20 2.809059292390718706e-28 3.459970229174107522e-21 3.717170717811429871e-25 6.427000595555569273e-24 1.332165422977898321e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.273263342606773901e-21 0.000000000000000000e+00 4.764223910075344171e-21 8.314350487193620632e-20 1.051450056667774788e+03 8.168839688527103633e-20 8.190008643736346989e-20 1.195333741924817023e-20 2.794092020471027764e-28 3.458207729269205515e-21 3.704656772631594405e-25 6.412545262718348352e-24 1.332052923099318275e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.266093743546382484e-21 0.000000000000000000e+00 4.768177659851565698e-21 8.305204950746395321e-20 1.052600047501424115e+03 8.383392609558838905e-20 8.198143666393939068e-20 1.233928682842983450e-20 2.779884265224938654e-28 3.456509606933370934e-21 3.692664747014348947e-25 6.398692345087431312e-24 1.331962653262465798e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.276576182392822193e-21 0.000000000000000000e+00 4.771966640057003644e-21 8.318920121183243926e-20 1.053750056544087101e+03 8.474970937505406955e-20 8.206279632838590086e-20 1.297231328355625808e-20 2.765763548131391993e-28 3.454803141902322164e-21 3.680672937013500178e-25 6.384839208108708578e-24 1.331888459206775590e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.258221971140575743e-21 0.000000000000000000e+00 4.775755680257348598e-21 8.336496229478137485e-20 1.054950056479768591e+03 8.189766280286129582e-20 8.214770136019182268e-20 1.344203838961888604e-20 2.751029003466599329e-28 3.453022496836472988e-21 3.668160279659883024e-25 6.370383875266316216e-24 1.331811039935497954e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.279436490979589806e-21 0.000000000000000000e+00 4.779709430034984480e-21 8.352383304477400634e-20 1.056150056415596055e+03 8.205653186790498018e-20 8.223261521201514195e-20 1.222336383712446690e-20 2.736794042833170967e-28 3.451290543902581039e-21 3.655648072735529439e-25 6.355928542422165021e-24 1.331702923481950880e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.294758554536031054e-21 0.000000000000000000e+00 4.783663179813101092e-21 8.342084496742383962e-20 1.057350056351569265e+03 8.145025403492508503e-20 8.231753785656126654e-20 1.359064103708522188e-20 2.722690514173909239e-28 3.449565543994619411e-21 3.643136320881400862e-25 6.341473209576258666e-24 1.331590423603383436e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.289892548973254297e-21 0.000000000000000000e+00 4.787625820827494308e-21 8.371558990053704419e-20 1.058550056287687767e+03 8.310129064042523564e-20 8.240246926664526194e-20 1.344004430869128805e-20 2.708586985512939497e-28 3.447832729827458504e-21 3.630625028802266496e-25 6.327017876728602293e-24 1.331485737975792452e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.288989247664465293e-21 0.000000000000000000e+00 4.791602076019384826e-21 8.377493108294651501e-20 1.059750056223950651e+03 8.326520126341301581e-20 8.248740941519135777e-20 1.523161381283630319e-20 2.694282965765242995e-28 3.446070229921072176e-21 3.618114201267801659e-25 6.312562543879206189e-24 1.331410738056752317e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.298821918129300169e-21 0.000000000000000000e+00 4.795578331211753818e-21 8.416473527263910759e-20 1.060950056160357917e+03 8.291495359715265764e-20 8.257235827523250240e-20 1.579276346804726850e-20 2.679970239251004323e-28 3.444307730014474448e-21 3.605603843113694398e-25 6.298107211028071088e-24 1.331335738137711429e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.282998446041098773e-21 0.000000000000000000e+00 4.799554586404600531e-21 8.435078708879050980e-20 1.062150056096908884e+03 8.185977083686329561e-20 8.265731581990961664e-20 1.367107403319522246e-20 2.665699946496951044e-28 3.442535400630393224e-21 3.593093959242801705e-25 6.283651878175205072e-24 1.331259427623046785e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.308353062720553947e-21 0.000000000000000000e+00 4.803530841597924212e-21 8.406409800603818545e-20 1.063350056033603096e+03 8.281726255643917285e-20 8.274228202247128077e-20 1.391342047718795407e-20 2.651590856332182399e-28 3.440754755563040167e-21 3.580584554626312606e-25 6.269196545320613283e-24 1.331182008351778930e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.310836384207652405e-21 0.000000000000000000e+00 4.807507096791722605e-21 8.418760683122085696e-20 1.064550055970439871e+03 8.115350018705670246e-20 8.282725685627304847e-20 1.451617178447219083e-20 2.637481766165737577e-28 3.438974110495475710e-21 3.568075634304939733e-25 6.254741212464304537e-24 1.331104589080510887e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.321393569519604097e-21 0.000000000000000000e+00 4.811483351985992700e-21 8.437330247483651564e-20 1.065750055907418982e+03 8.157231402018738549e-20 8.291224029477710973e-20 1.348314487503921520e-20 2.623653488853028809e-28 3.437246794633085073e-21 3.555567203390127875e-25 6.240285879606280304e-24 1.330993549257769196e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.345549718015979210e-21 0.000000000000000000e+00 4.815459607180735250e-21 8.428643063380506271e-20 1.066950055844539747e+03 8.134548346250023634e-20 8.299723231155154459e-20 1.290647458447341777e-20 2.610157018971999390e-28 3.435521794723474366e-21 3.543059267065310747e-25 6.225830546746550870e-24 1.330881049379216986e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.334089842966675149e-21 0.000000000000000000e+00 4.819435862375946493e-21 8.427950443581142843e-20 1.068150055781801939e+03 8.411585710974995271e-20 8.308223288027001015e-20 1.391683039402989020e-20 2.596660549089379440e-28 3.433796794813659783e-21 3.530551830587163631e-25 6.211375213885116969e-24 1.330779488732613780e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.331487862565239830e-21 0.000000000000000000e+00 4.823412117571627182e-21 8.452373440403296594e-20 1.069400065457263736e+03 8.250961950619715768e-20 8.317078489502173536e-20 1.423020962958714888e-20 2.582464707142515304e-28 3.431999905905183556e-21 3.517523686672764721e-25 6.196317458148863997e-24 1.330701363208167029e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.351302828015461874e-21 0.000000000000000000e+00 4.827561023684979434e-21 8.466383129901868110e-20 1.070650055651549792e+03 8.123829280209000601e-20 8.325934475110847988e-20 1.129961987559158879e-20 2.568192091833213360e-28 3.430203045000897068e-21 3.504496300063949225e-25 6.181259937085023593e-24 1.330623238901301841e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.331415944562468567e-21 0.000000000000000000e+00 4.831734622024847439e-21 8.430765551736558406e-20 1.071850055589244676e+03 8.203724220261344287e-20 8.334437152370988385e-20 1.376131870702607532e-20 2.554490274362807342e-28 3.428515074027113082e-21 3.491990438673732041e-25 6.166804604218377109e-24 1.330524089700578999e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.350955803413137263e-21 0.000000000000000000e+00 4.835741307653822692e-21 8.475727994778400196e-20 1.073050055527078939e+03 8.218397151078608773e-20 8.342940674184014186e-20 1.432894790065317677e-20 2.541364099657303452e-28 3.426842346841041403e-21 3.479485099382858177e-25 6.152349271350052607e-24 1.330414998909269624e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.361921373270989565e-21 0.000000000000000000e+00 4.839747993283262876e-21 8.493540853910974217e-20 1.074250055465051673e+03 8.476562122460592204e-20 8.351445037970125379e-20 1.213653089013378496e-20 2.528262923863906621e-28 3.425169619654776379e-21 3.466980287840961948e-25 6.137893938480059638e-24 1.330305908117966269e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.357180806578418473e-21 0.000000000000000000e+00 4.843754678913164982e-21 8.467699194677871117e-20 1.075450055403163333e+03 8.320340472969861498e-20 8.359950241159776325e-20 1.169118881643455329e-20 2.515186463076573189e-28 3.423446795357952320e-21 3.454476009779228970e-25 6.123438605608393059e-24 1.330229489321572338e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.387546605218926644e-21 0.000000000000000000e+00 4.847761364543531268e-21 8.469962513334458608e-20 1.076650055341412553e+03 8.246351788055123221e-20 8.368456281193598720e-20 1.446053469305784279e-20 2.502282934328810978e-28 3.421721795446719620e-21 3.441972271011900880e-25 6.108983272735069767e-24 1.330154489402553644e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.377697721939614238e-21 0.000000000000000000e+00 4.851768050174357218e-21 8.520938410877488771e-20 1.077900064941087294e+03 8.427295139861504857e-20 8.377317695198517970e-20 1.358616832861629643e-20 2.488841654633484908e-28 3.419924906647187081e-21 3.428948022269899418e-25 6.093925517911755666e-24 1.330063861866367976e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.390525004799237701e-21 0.000000000000000000e+00 4.855941713306972045e-21 8.515321467631493435e-20 1.079150055213206542e+03 8.417594624550362684e-20 8.386179874579236125e-20 1.292222346961563181e-20 2.475464119972796680e-28 3.418128045631015348e-21 3.415924573244547966e-25 6.078867995910327743e-24 1.329946675398892531e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.419050574319981076e-21 0.000000000000000000e+00 4.860115311906717965e-21 8.513840596651026280e-20 1.080350055151878450e+03 8.350395621946480243e-20 8.394688478883083233e-20 1.406614855963688361e-20 2.462730002976536787e-28 3.416403045719174776e-21 3.403954872698813127e-25 6.064876816687113206e-24 1.329834175520377185e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.493376085706097892e-21 0.000000000000000000e+00 4.864121997538954509e-21 8.540632099521626386e-20 1.081550055090686328e+03 8.257222152949645682e-20 8.403197909697418747e-20 1.431883185008506957e-20 2.449995885978833894e-28 3.414715074722073497e-21 3.393599045484656916e-25 6.052292564056099914e-24 1.329749849787284600e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.439938731967303689e-21 0.000000000000000000e+00 4.868128886657092537e-21 8.552989456495351962e-20 1.082800064647209183e+03 8.260171223446900465e-20 8.412062844524789857e-20 1.296844600374467202e-20 2.436846383450331771e-28 3.412972637158436167e-21 3.382811741971898647e-25 6.039183866678922437e-24 1.329674091710301512e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.422902451102722626e-21 0.000000000000000000e+00 4.872310662505593725e-21 8.540101197383761552e-20 1.084050054963638104e+03 6.778005686954557461e-19 8.420928534158094021e-20 1.151371497151701531e-20 2.423787661085756789e-28 3.411228045989770898e-21 3.372024707011093410e-25 6.026075371070256715e-24 1.329596675782418700e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.441458330204079648e-21 0.000000000000000000e+00 4.876492373988377917e-21 8.528069842600096167e-20 1.085250054902862757e+03 8.315309509201314089e-20 8.429440497594608029e-20 1.317699987077583304e-20 2.411251191132445507e-28 3.409503046077135127e-21 3.361669171111399316e-25 6.013491118434872788e-24 1.329484175903912193e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.442613487355028984e-21 0.000000000000000000e+00 4.880506847908090220e-21 8.560515899190481307e-20 1.086450054842221789e+03 8.287733332413678029e-20 8.437953277349075196e-20 1.343748545077647900e-20 2.398848846567220228e-28 3.407778046164306011e-21 3.351313731482168915e-25 6.000906865798079738e-24 1.329371676025412834e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.454499780195931165e-21 0.000000000000000000e+00 4.884521321828252408e-21 8.573006415473705386e-20 1.087700064355978611e+03 8.201153297360818075e-20 8.446821689593024544e-20 1.499813093198077051e-20 2.385966395578386045e-28 3.406018094060029434e-21 3.340526835895960845e-25 5.987798168869384213e-24 1.329271061839802204e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.447076534236661118e-21 0.000000000000000000e+00 4.888703097533684085e-21 8.607539316446774779e-20 1.088950054716315663e+03 8.518680990836409877e-20 8.455690846246946551e-20 1.299511848276784994e-20 2.373092386288658508e-28 3.404313561750478517e-21 3.329740212049921991e-25 5.974689672800259720e-24 1.329195304926279037e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.446398208376913053e-21 0.000000000000000000e+00 4.892884809163358803e-21 8.583657729820780972e-20 1.090150054656085786e+03 8.228291073466611219e-20 8.464206127486598910e-20 1.448393866962216263e-20 2.360922975134754043e-28 3.402677198196246729e-21 3.319385074938851436e-25 5.962105420159154810e-24 1.329122577732103131e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.456029897121515468e-21 0.000000000000000000e+00 4.896899283084895473e-21 8.615875809272477381e-20 1.091400064137802701e+03 8.514974766629247489e-20 8.473077137206459199e-20 1.284725809337041777e-20 2.348246408390753639e-28 3.400906157801908750e-21 3.308598497769236654e-25 5.948996723566458182e-24 1.329016988019222369e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.454734141979869552e-21 0.000000000000000000e+00 4.901081058683140873e-21 8.598630080255194418e-20 1.092650054531031856e+03 8.326936582136749914e-20 8.481948883599338041e-20 1.410727647410884599e-20 2.335619454689681185e-28 3.399109296611641977e-21 3.297812194886422918e-25 5.935888227152398096e-24 1.328899801540582737e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.464943556734760017e-21 0.000000000000000000e+00 4.905262770422852395e-21 8.627136446498789597e-20 1.093850054471208978e+03 8.476329670617160224e-20 8.490466643142102317e-20 1.267262028454048411e-20 2.323619455287909960e-28 3.397390833161344912e-21 3.287457369136743352e-25 5.923303974507025407e-24 1.328792275053283166e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.466772527619719005e-21 0.000000000000000000e+00 4.909277244345751510e-21 8.613260236463440512e-20 1.095100063921101309e+03 8.311932499304099179e-20 8.499340226287794478e-20 1.069911486867803210e-20 2.311119360788987236e-28 3.395648395746343482e-21 3.276671119711600141e-25 5.910195278248069257e-24 1.328716516982874947e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.454864262047254882e-21 0.000000000000000000e+00 4.913481770985552532e-21 8.595186925264244793e-20 1.096350054346998604e+03 8.597386077537983845e-20 8.508214538465226471e-20 1.370929339970379875e-20 2.298894336653888236e-28 3.393905984849638471e-21 3.265885147245944125e-25 5.897086781491422363e-24 1.328640760065443685e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.457595547789809657e-21 0.000000000000000000e+00 4.917690687631525186e-21 8.646582421067402369e-20 1.097600063775508488e+03 8.626932435566132202e-20 8.517089846943405212e-20 1.469125385771847640e-20 2.286922817784273481e-28 3.392181731215216179e-21 3.255099124735469821e-25 5.883978085456700577e-24 1.328546818264320234e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.482248692563941017e-21 0.000000000000000000e+00 4.921899668262317802e-21 8.671526974285984727e-20 1.098850054223353482e+03 8.396612133572822214e-20 8.525965879343755809e-20 1.363152866659673443e-20 2.274951480695198072e-28 3.390477198786335846e-21 3.244313381064740109e-25 5.870869588469891155e-24 1.328433182886211487e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.477832718041271690e-21 0.000000000000000000e+00 4.926108584982191998e-21 8.662938278953976318e-20 1.100100063630577324e+03 8.510875355332683045e-20 8.534842902394842755e-20 1.322586221524470888e-20 2.262853499307566393e-28 3.388772640503757645e-21 3.233527590013392201e-25 5.857760892658393542e-24 1.328319545784544588e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.462033600893796910e-21 0.000000000000000000e+00 4.930317565541310680e-21 8.665344611373551360e-20 1.101350054100269517e+03 8.527315934617749583e-20 8.543720644301131540e-20 1.354315392896141306e-20 2.250706533096204162e-28 3.387068108045086712e-21 3.222742079744286870e-25 5.844652395442475128e-24 1.328237730192892998e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.476955905257941186e-21 0.000000000000000000e+00 4.934526482334747877e-21 8.679060154879393375e-20 1.102600063486303270e+03 8.601386173827222367e-20 8.552599371252770070e-20 1.239740948819235823e-20 2.238559410121546853e-28 3.385363549791404607e-21 3.211956524818733388e-25 5.831543699853195171e-24 1.328161972126419957e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.479232799206581524e-21 0.000000000000000000e+00 4.938735462822516872e-21 8.670704853744356875e-20 1.103850053977743300e+03 8.502063946749460882e-20 8.561478812034827919e-20 1.294683664753991614e-20 2.226945212755367106e-28 3.383651439909812294e-21 3.201171252682194756e-25 5.818435202409209547e-24 1.328078637819633228e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.470040718596917574e-21 0.000000000000000000e+00 4.942944379689182289e-21 8.687461844342875808e-20 1.105100063342682233e+03 8.608581145559107199e-20 8.570359232301029743e-20 1.248964590915902782e-20 2.215330840027420064e-28 3.381909002613230730e-21 3.190385938675452387e-25 5.805326507041149545e-24 1.327965000721872919e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.468645138468919603e-21 0.000000000000000000e+00 4.947153360105921334e-21 8.689536035266010507e-20 1.106350053855770739e+03 8.415762757152865885e-20 8.579240361414624933e-20 1.438954453693756735e-20 2.203748077801963157e-28 3.380166591594986373e-21 3.179600909530890532e-25 5.792218009370138494e-24 1.327851365337935601e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.472187702192706044e-21 0.000000000000000000e+00 4.951362277045480190e-21 8.727632173045070853e-20 1.107600063199709439e+03 8.579965056246100834e-20 8.588122464494915456e-20 1.335336341230606650e-20 2.192290849300948089e-28 3.378473445765090560e-21 3.168815841366619301e-25 5.779109314222305155e-24 1.327760190139788398e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.481297876515143693e-21 0.000000000000000000e+00 4.955595410304035541e-21 8.719949245928999130e-20 1.108850053734348194e+03 8.546815073843850833e-20 8.597005271480921904e-20 1.400339476950128271e-20 2.180833793200602404e-28 3.376819046528068445e-21 3.158031060206289393e-25 5.766000816325299436e-24 1.327686661360700137e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.474674590247382475e-21 0.000000000000000000e+00 4.959839268677335096e-21 8.738869543612059859e-20 1.110100063057380567e+03 8.473953532883590046e-20 8.605889046959498838e-20 1.451324410909991128e-20 2.169445144967648996e-28 3.375164622424055035e-21 3.147246242943276536e-25 5.752892121396708283e-24 1.327613131476421680e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.512896389513922978e-21 0.000000000000000000e+00 4.964083190839343035e-21 8.756085753604321061e-20 1.111350053613471800e+03 8.817905526884438201e-20 8.614773521443048693e-20 1.406810207896830474e-20 2.158159515946939730e-28 3.373468108708901993e-21 3.136461714896853170e-25 5.739783623274733518e-24 1.327505911171081895e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.529674045085861900e-21 0.000000000000000000e+00 4.968327049285475843e-21 8.757641944771021339e-20 1.112600062915691296e+03 8.604385662502218603e-20 8.623658958987959925e-20 1.361597048044211907e-20 2.146873717675471964e-28 3.371763550569511794e-21 3.125677153733668268e-25 5.726674928564403747e-24 1.327392274079124578e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.513593591618143446e-21 0.000000000000000000e+00 4.972570971376821713e-21 8.759193245266815636e-20 1.113850053493138148e+03 8.524461597009564928e-20 8.632545090677623845e-20 1.338348328688657775e-20 2.135682380901089003e-28 3.370059017963902561e-21 3.114892884072999326e-25 5.713566430218475267e-24 1.327286216060191563e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.509499274236870337e-21 0.000000000000000000e+00 4.976814829895459765e-21 8.764362720347277507e-20 1.115100062774637308e+03 8.440557260254884588e-20 8.641432180039928453e-20 1.399516174529432131e-20 2.124553726840656432e-28 3.368354459852767485e-21 3.104108584352854248e-25 5.700457735725437097e-24 1.327210458000166251e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.514872704460972945e-21 0.000000000000000000e+00 4.981058751916457283e-21 8.782694445827619003e-20 1.116400062701538900e+03 8.782294552977137383e-20 8.650675555942493255e-20 1.364597216918340021e-20 2.112980013205727042e-28 3.366581732679719901e-21 3.092893137321456411e-25 5.686824795446555879e-24 1.327131670207194430e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.531801867226909146e-21 0.000000000000000000e+00 4.985472397797915459e-21 8.786384385392714988e-20 1.117650053311262127e+03 8.582774123602490299e-20 8.659564187060736873e-20 1.224764030627135017e-20 2.101995532688706904e-28 3.364907282382153231e-21 3.082109270835914195e-25 5.673716296762149678e-24 1.327035189902136778e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.508832207496667947e-21 0.000000000000000000e+00 4.989716256426135164e-21 8.774453094942508256e-20 1.118900062561442610e+03 8.807654027650390369e-20 8.668453767741218424e-20 1.271418189784740188e-20 2.091038308747124885e-28 3.363252858374561203e-21 3.071325379080448495e-25 5.660607602597546099e-24 1.326924895082262270e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.548201385611199388e-21 0.000000000000000000e+00 4.993960178340802540e-21 8.790029065149508127e-20 1.120200062488839649e+03 8.741134322581430226e-20 8.677699726700209729e-20 1.256461837536618058e-20 2.079655460096424383e-28 3.361532270235359032e-21 3.060110360600100154e-25 5.646974662313469929e-24 1.326810189324858165e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.543074999378171533e-21 0.000000000000000000e+00 4.998379682007466634e-21 8.796996320311210685e-20 1.121450053130618471e+03 8.656289239647356340e-20 8.686590833946974893e-20 1.402667023487662543e-20 2.068855540951455670e-28 3.359877870856534306e-21 3.049326910350816833e-25 5.633866163292900262e-24 1.326733721204050960e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.525514845219510621e-21 0.000000000000000000e+00 5.002635058251637513e-21 8.827761978823698113e-20 1.122700062349691052e+03 8.515231457007186241e-20 8.695482882741386637e-20 1.332063556124242908e-20 2.058055461298668578e-28 3.358223446890114673e-21 3.038543439801502797e-25 5.620757469454521345e-24 1.326660191325996793e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.547710912328343184e-21 0.000000000000000000e+00 5.006890497738982073e-21 8.825686668470514755e-20 1.124000062277578309e+03 8.565516095456309779e-20 8.704731400721621240e-20 1.348813203906955711e-20 2.046873755465189967e-28 3.356490824166938776e-21 3.027328863843768891e-25 5.607124529165304592e-24 1.326574093164354726e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.545146668292738680e-21 0.000000000000000000e+00 5.011316121920202585e-21 8.837347903617162499e-20 1.125250052951194903e+03 8.821355168664493188e-20 8.713624961079199553e-20 1.422268509793416795e-20 2.036230977729825848e-28 3.354786291430188761e-21 3.016545843461067528e-25 5.594016029810855591e-24 1.326460457766070171e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.551848793343608825e-21 0.000000000000000000e+00 5.015571498272760437e-21 8.857650069135439977e-20 1.126500062139368083e+03 8.662085245713876947e-20 8.722519455064238568e-20 1.376935364180411184e-20 2.025588042356237145e-28 3.353081733446316276e-21 3.005762807938701926e-25 5.580907336296515650e-24 1.326346820684665784e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.577047524706426018e-21 0.000000000000000000e+00 5.019826937654913112e-21 8.859360010647087601e-20 1.127800062067740782e+03 8.677329343283007265e-20 8.731770508321283686e-20 1.614176016311102463e-20 2.014762826446783306e-28 3.351341094322107758e-21 2.994548689088546522e-25 5.567274396002207537e-24 1.326230778196413860e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.583737828126075011e-21 0.000000000000000000e+00 5.024252561837786462e-21 8.908431253077026945e-20 1.129100061996278555e+03 8.775727399028782770e-20 8.741022423510307691e-20 1.563442342038817268e-20 2.004146160363725020e-28 3.349620506181396064e-21 2.983334730080563678e-25 5.553641455706168509e-24 1.326116072439033264e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.591862870244361517e-21 0.000000000000000000e+00 5.028678186021221794e-21 8.908507255427891926e-20 1.130400061924980719e+03 8.878784558987839455e-20 8.750275197897277288e-20 1.433599543128849437e-20 1.993529494279324401e-28 3.347899918040466950e-21 2.972120932724052717e-25 5.540008515408405178e-24 1.326001368502979602e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.582430984590633044e-21 0.000000000000000000e+00 5.033103810205216848e-21 8.895720914514866694e-20 1.131650052651731585e+03 8.529065593329211393e-20 8.759172838556269352e-20 1.193632469545610592e-20 1.983229850660549543e-28 3.346245518549178825e-21 2.962093320870695985e-25 5.527608821646316739e-24 1.325927839712792042e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.597214332259290380e-21 0.000000000000000000e+00 5.037359186738660900e-21 8.869079513502352553e-20 1.132900061788329367e+03 8.817096648521253638e-20 8.768071399720002424e-20 1.421235819866209668e-20 1.972901203737576015e-28 3.344591094691916913e-21 2.953117486113634636e-25 5.516196901532859188e-24 1.325854309839681722e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.565200706391312783e-21 0.000000000000000000e+00 5.041623624381361748e-21 8.911212918132912130e-20 1.134200061717508561e+03 8.728422723789098091e-20 8.777326670050859540e-20 1.617823783643742496e-20 1.962159511060182723e-28 3.342870506550356230e-21 2.943782721074210896e-25 5.504328592010201563e-24 1.325766072825843294e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.590448579518537690e-21 0.000000000000000000e+00 5.046081856444438078e-21 8.953864226780951183e-20 1.135500061646850099e+03 8.752322097687866603e-20 8.786582788962292131e-20 1.438369369263843597e-20 1.951860622731065455e-28 3.341149918408580761e-21 2.934447991406261651e-25 5.492460282486061346e-24 1.325651367068474923e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.608592543346483185e-21 0.000000000000000000e+00 5.050540088508070369e-21 8.932382053449981651e-20 1.136800061576353073e+03 8.688441051625867320e-20 8.795839753775342477e-20 1.421625341137637794e-20 1.941561734400669529e-28 3.339429330266591633e-21 2.925113297448439936e-25 5.480591972960446618e-24 1.325536661311112759e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.599917189940158352e-21 0.000000000000000000e+00 5.054998320572257117e-21 8.938793451062693226e-20 1.138100061506017255e+03 8.870872802898868776e-20 8.805097561822073994e-20 1.556684749592585756e-20 1.931296186236331552e-28 3.337735214521624750e-21 2.915778639543730665e-25 5.468723663433361053e-24 1.325448427923575850e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.610227776051334906e-21 0.000000000000000000e+00 5.059456552636996066e-21 8.970412595513213192e-20 1.139350052295898649e+03 8.802112543785796920e-20 8.814000027947254507e-20 1.408913871553142197e-20 1.921532369288702747e-28 3.336117579381778186e-21 2.906803106914613710e-25 5.457311910815688740e-24 1.325374899129738239e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.625558257660492454e-21 0.000000000000000000e+00 5.063743282884371933e-21 8.954795350380156710e-20 1.140600061371206493e+03 8.639485786397085379e-20 8.822903399114158950e-20 1.316198032662225018e-20 1.911768409511576244e-28 3.334499918773403193e-21 2.897827476955703726e-25 5.445899991261776051e-24 1.325301367455263324e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.651637571943940819e-21 0.000000000000000000e+00 5.068030075839962090e-21 8.949578143186159166e-20 1.141900061301338155e+03 8.858452177798892865e-20 8.832163656803515452e-20 1.429372930474348081e-20 1.901669527979696804e-28 3.332779330630582004e-21 2.888492926445379299e-25 5.434031681730422706e-24 1.325186661697908495e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.601607235951572260e-21 0.000000000000000000e+00 5.072488307906304977e-21 8.975849521452789774e-20 1.143200061231628979e+03 8.730620046212613319e-20 8.841424747365412340e-20 1.352598047765691184e-20 1.891659528516457187e-28 3.331058742487549790e-21 2.879158413376939965e-25 5.422163372197615422e-24 1.325071955940560249e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.657282212525111721e-21 0.000000000000000000e+00 5.076946539973193293e-21 8.973312766801001040e-20 1.144500061162077827e+03 8.813251587458969021e-20 8.850686668185369620e-20 1.321023617857585970e-20 1.881649529052000795e-28 3.329357064220185788e-21 2.869823938115761509e-25 5.410295062663365953e-24 1.324958510840303611e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.641883346470593974e-21 0.000000000000000000e+00 5.081404772040623278e-21 8.977694548919543819e-20 1.145800061092684700e+03 9.012885369332315946e-20 8.859949416659614267e-20 1.526977134526602420e-20 1.871564095254731800e-28 3.327685635737976783e-21 2.860489501031977717e-25 5.398426753127674300e-24 1.324847082390320666e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.621135764908130046e-21 0.000000000000000000e+00 5.085867060074506795e-21 9.019336833825926873e-20 1.147100061023448689e+03 8.732472087672742740e-20 8.869212990195006797e-20 1.473780556601186727e-20 1.861431524365805695e-28 3.326014207255565781e-21 2.851155102500572663e-25 5.386558443590547809e-24 1.324735653940343551e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.640332778143843577e-21 0.000000000000000000e+00 5.090365440294447280e-21 9.019688457287933182e-20 1.148400060954369792e+03 8.806226502186758591e-20 8.878477386209007562e-20 1.375741611256660730e-20 1.851298953475654968e-28 3.324335215235521369e-21 2.841820742901453723e-25 5.374690134051986480e-24 1.324648428785056489e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.626918511454864514e-21 0.000000000000000000e+00 5.094863820514932442e-21 9.013279464282852906e-20 1.149700060885446646e+03 9.014856212195748907e-20 8.887742602129610547e-20 1.286643272812128421e-20 1.841788746206426176e-28 3.322652862383539423e-21 2.832486422619541116e-25 5.362821824512003537e-24 1.324571958280173519e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.640993573389325396e-21 0.000000000000000000e+00 5.099362200735955510e-21 9.009326732964370678e-20 1.151000060816679706e+03 8.936832794972688253e-20 8.897008635395304852e-20 1.234635541235606738e-20 1.832330368328373791e-28 3.320974209259031314e-21 2.823152142044831264e-25 5.350953514970595308e-24 1.324492797067044416e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.633800310796572906e-21 0.000000000000000000e+00 5.103860580957519494e-21 9.011185180045478141e-20 1.152300060748067381e+03 8.726140168994935795e-20 8.906275483455000062e-20 1.654426721209221753e-20 1.822863997608660368e-28 3.319339923631001246e-21 2.813817901572509297e-25 5.339085205427774281e-24 1.324381368617075765e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.619237056226622271e-21 0.000000000000000000e+00 5.108358961179619127e-21 9.087273142462955025e-20 1.153600060679610124e+03 8.766705339079280697e-20 8.915543143768003375e-20 1.344864215375878335e-20 1.813301775889978944e-28 3.317705638002775952e-21 2.804483701603004151e-25 5.327216895883538254e-24 1.324269940167113132e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.621415992481249317e-21 0.000000000000000000e+00 5.112857341402254409e-21 9.045205240698305059e-20 1.154900060611306799e+03 9.010298911409518248e-20 8.924811613803943771e-20 1.430693500661601671e-20 1.803739554170165496e-28 3.316038155073270569e-21 2.795149542542105202e-25 5.315348586337896775e-24 1.324157251061461586e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.643249643381070624e-21 0.000000000000000000e+00 5.117355721625423084e-21 9.067593258864590587e-20 1.156200060543157178e+03 9.037081409238901982e-20 8.934080891042733492e-20 1.289602272681887133e-20 1.794212893386390958e-28 3.314317566928174375e-21 2.785815424801028841e-25 5.303480276790852050e-24 1.324042545304160548e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.646252232884651023e-21 0.000000000000000000e+00 5.121854101849122894e-21 9.055580545457756998e-20 1.157550070191350187e+03 8.698149024192761127e-20 8.943707599929750458e-20 1.514778322365410045e-20 1.784402823276188780e-28 3.312530789452624720e-21 2.776122276931085237e-25 5.291155405070708164e-24 1.323923426929430558e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.633492131434895299e-21 0.000000000000000000e+00 5.126525530327270709e-21 9.099810487324484546e-20 1.158900060402103918e+03 8.902986053202132965e-20 8.953335035187774852e-20 1.349323398638250955e-20 1.774592894411378716e-28 3.310817066923069230e-21 2.766429314105925932e-25 5.278830710804070894e-24 1.323838513792999550e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.642957763261880162e-21 0.000000000000000000e+00 5.131196891546190398e-21 9.083282775215078412e-20 1.160200060334423597e+03 8.947823419652913472e-20 8.962606780429451665e-20 1.531693265031149486e-20 1.765398499513142086e-28 3.309182781293867429e-21 2.757095326141213480e-25 5.266962401252742227e-24 1.323764228159707805e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.624260692537757794e-21 0.000000000000000000e+00 5.135710557649683164e-21 9.121213907480890232e-20 1.161500060266894934e+03 8.864372093792802822e-20 8.971879322705092974e-20 1.646573440830565392e-20 1.756361743225800468e-28 3.307548495664474540e-21 2.747761381231047007e-25 5.255094091700027946e-24 1.323684226524726287e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.652367486301092226e-21 0.000000000000000000e+00 5.140224812875441247e-21 9.150429504552946342e-20 1.162800060199517020e+03 8.818579326729049451e-20 8.981152659546012887e-20 1.631220719128663074e-20 1.747324986937410903e-28 3.305914210034892819e-21 2.738427479815698279e-25 5.243225782145938337e-24 1.323572798074792806e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.630283771292084203e-21 0.000000000000000000e+00 5.144739068101722191e-21 9.156706096888653057e-20 1.164100060132289627e+03 8.960111618320768641e-20 8.990426788493506646e-20 1.476163571266450028e-20 1.738184020177733898e-28 3.304279924405121515e-21 2.729093622341456126e-25 5.231357472590474134e-24 1.323461369624866285e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.621838518643778984e-21 0.000000000000000000e+00 5.149253323328525994e-21 9.139466964839807568e-20 1.165400060065212301e+03 8.825713634996174511e-20 8.999701707098794048e-20 1.492936247605214967e-20 1.729011798428779856e-28 3.302645638775161379e-21 2.719759809260734342e-25 5.219489163033639745e-24 1.323349941174946158e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.651236861021004325e-21 0.000000000000000000e+00 5.153767578555850400e-21 9.151448271768390938e-20 1.166750069637880870e+03 8.936425344280248552e-20 9.009334255328916495e-20 1.355287728813071793e-20 1.719501691635940533e-28 3.300948483883806660e-21 2.710066981619603719e-25 5.207164292002994560e-24 1.323234226188949964e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.629032556798483426e-21 0.000000000000000000e+00 5.158455492467243292e-21 9.139429759277172997e-20 1.168100059926374797e+03 8.940463766060223009e-20 9.018967512174691177e-20 1.460157184793188056e-20 1.710380135632603120e-28 3.299251353235414474e-21 2.700374341325797822e-25 5.194839597026630535e-24 1.323118512855902706e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.632805005515116831e-21 0.000000000000000000e+00 5.163143339414258153e-21 9.165082896241676702e-20 1.169400059859755629e+03 8.964643964626818334e-20 9.028244845241614789e-20 1.494789787389024837e-20 1.701596352298949019e-28 3.297617067604878816e-21 2.691040667744882638e-25 5.182971287465613591e-24 1.323038514655039912e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.660244243572932117e-21 0.000000000000000000e+00 5.167657594643174460e-21 9.179916643696141921e-20 1.170700059793284481e+03 8.995942565633129844e-20 9.037522958084539574e-20 1.327985437991776987e-20 1.692841763971208573e-28 3.295982781974156584e-21 2.681707040467574310e-25 5.171102977903244828e-24 1.322964229021772617e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.701231638708082233e-21 0.000000000000000000e+00 5.172171849872603848e-21 9.163569662032849917e-20 1.172050069322978970e+03 9.045104650105901048e-20 9.047158812703361279e-20 1.443550270194888635e-20 1.683851430238323934e-28 3.294285627136826456e-21 2.672014408140733262e-25 5.158778107264929698e-24 1.322879940869904178e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.646968163093752627e-21 0.000000000000000000e+00 5.176859763634768766e-21 9.190318060924795883e-20 1.173400059655700034e+03 8.888251399182320708e-20 9.056795365943767051e-20 1.562580965562841759e-20 1.674861224346905337e-28 3.292588496432834328e-21 2.662321964651029755e-25 5.146453411884795119e-24 1.322764227533130320e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.723632131570647543e-21 0.000000000000000000e+00 5.181576902194710429e-21 9.219558125887566855e-20 1.174700059589680905e+03 9.114908481057595882e-20 9.066075863091362254e-20 1.513182344378127816e-20 1.666152931434040445e-28 3.290954210801543721e-21 2.652988482919167564e-25 5.134585102318300371e-24 1.322652799083241415e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.682001188553466949e-21 0.000000000000000000e+00 5.186128553602519769e-21 9.220291814727130090e-20 1.176000059523807977e+03 8.953083654059177206e-20 9.075357130294054735e-20 1.565151828118938683e-20 1.657385154100539357e-28 3.289319925170069924e-21 2.643655049512120581e-25 5.122716792750470702e-24 1.322541370633359844e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.665685700185752640e-21 0.000000000000000000e+00 5.190680205010841437e-21 9.238035456170771468e-20 1.177350069010912421e+03 8.865715000542000149e-20 9.084996250061693170e-20 1.529895129856036645e-20 1.648280090115290839e-28 3.287622770386281402e-21 2.633962620993613227e-25 5.110391922500980451e-24 1.322425655654844873e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.695114895031470253e-21 0.000000000000000000e+00 5.195406953391296589e-21 9.241740649887680308e-20 1.178700059387459305e+03 8.940350371921562398e-20 9.094636058624018221e-20 1.603907440337412388e-20 1.639454751203236333e-28 3.285925639627193759e-21 2.624270382931761011e-25 5.098067226720739186e-24 1.322309942314397266e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.706387981616672347e-21 0.000000000000000000e+00 5.200133634860520349e-21 9.263809664626067668e-20 1.180000059322032484e+03 9.317425800838723830e-20 9.103919680464540425e-20 1.450587016513931928e-20 1.631050427301887775e-28 3.284333260828626839e-21 2.614937101470100588e-25 5.086198917148837164e-24 1.322234706092138649e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.719992371611815880e-21 0.000000000000000000e+00 5.204685286270403826e-21 9.247712090988119756e-20 1.181350068777244360e+03 9.105945485353626524e-20 9.113561237595616188e-20 1.492812832566218644e-20 1.622322798607653191e-28 3.282683249272256948e-21 2.605244832696695674e-25 5.073874047190508782e-24 1.322159705644906772e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.721723650486730105e-21 0.000000000000000000e+00 5.209412034539194163e-21 9.263942033788057896e-20 1.182700059186605586e+03 9.076445186192604455e-20 9.123203476213521654e-20 1.569527909725933082e-20 1.613939633043045824e-28 3.281022782736839016e-21 2.595552755693628335e-25 5.061549351110689844e-24 1.322075656861164989e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.714174207249622899e-21 0.000000000000000000e+00 5.214138716123310176e-21 9.286076300355841448e-20 1.184050068620411139e+03 9.164861324057550920e-20 9.132846665644025717e-20 1.381684504559532920e-20 1.605569574553451101e-28 3.279325628020054800e-21 2.585860597759083138e-25 5.049224481347790336e-24 1.321959941887303471e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.719347544276567148e-21 0.000000000000000000e+00 5.218865464317150993e-21 9.265724856666287627e-20 1.185400059051795552e+03 8.962367815280620570e-20 9.142490531685895514e-20 1.367146446745577498e-20 1.597183412874668168e-28 3.277628497192028646e-21 2.577117193067652037e-25 5.037823086104806259e-24 1.321844228542240215e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.768303557276247950e-21 0.000000000000000000e+00 5.223592145978375674e-21 9.273294142679317428e-20 1.186700058987105649e+03 9.156941277010931029e-20 9.151778048242654523e-20 1.516002699047043331e-20 1.589018007875585310e-28 3.276022150126870985e-21 2.569362392438283802e-25 5.027490995707452167e-24 1.321734704992765143e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.760085042143823917e-21 0.000000000000000000e+00 5.228168733120096056e-21 9.305526250410408442e-20 1.188050068389375610e+03 8.940952415089063581e-20 9.161423636969988711e-20 1.381552224320193113e-20 1.580538489359706091e-28 3.274372138635207450e-21 2.561309287556454598e-25 5.016761441956971482e-24 1.321622204326421258e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.781734552304895988e-21 0.000000000000000000e+00 5.232941655846771443e-21 9.294186558510636728e-20 1.189400058853201926e+03 9.093681511061387658e-20 9.171069895148598693e-20 1.504258180086720997e-20 1.572102338130976708e-28 3.272722150290530810e-21 2.553256309835747633e-25 5.006032038724737491e-24 1.321509705238299097e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.787762815753506488e-21 0.000000000000000000e+00 5.237714511617077206e-21 9.322751467865629774e-20 1.190750068234304308e+03 9.064630125802734942e-20 9.180717090736973104e-20 1.445835082612499667e-20 1.563739577316147388e-28 3.271106862942358735e-21 2.545203233593501620e-25 4.995302485142491353e-24 1.321397204573759267e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.810943186431120270e-21 0.000000000000000000e+00 5.242487434268915168e-21 9.323118446525201530e-20 1.192100058719904609e+03 8.969393611389399442e-20 9.190364950997926486e-20 1.412888669200874645e-20 1.555376933551293159e-28 3.269494374306780583e-21 2.537150284526899795e-25 4.984573081737203288e-24 1.321284705483862580e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.820238156096095789e-21 0.000000000000000000e+00 5.247260290116201705e-21 9.327630783954287798e-20 1.193450068079934454e+03 9.223289973287742333e-20 9.200013743342606610e-20 1.507515586902226722e-20 1.547233280030704704e-28 3.267859914413796546e-21 2.529097237469274675e-25 4.973843528322437177e-24 1.321181373261273939e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.860286872780621476e-21 0.000000000000000000e+00 5.252033212693538527e-21 9.352109779775027225e-20 1.194800058587209833e+03 9.229947596945169986e-20 9.209663195621583319e-20 1.529981004808857057e-20 1.539218599545406993e-28 3.266162783490364637e-21 2.521044317609915580e-25 4.963114124744880415e-24 1.321104231026987638e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.856662779757120725e-21 0.000000000000000000e+00 5.256806068617456764e-21 9.365252171425840092e-20 1.196150067926261499e+03 8.912423336177312950e-20 9.219313574700730282e-20 1.742672910173148115e-20 1.531203807258826958e-28 3.264465628892699940e-21 2.512991300295963149e-25 4.952384571496843484e-24 1.321027087716610362e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.893272703125223794e-21 0.000000000000000000e+00 5.261578991120625723e-21 9.411965164018573915e-20 1.197500058455113503e+03 9.047840200886011742e-20 9.228964609015889398e-20 1.720383583292132828e-20 1.523107756745480160e-28 3.262824930178614634e-21 2.504938410211213368e-25 4.941655167747801198e-24 1.320926372546151816e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.869610485274273288e-21 0.000000000000000000e+00 5.266351847120828089e-21 9.417244813313336714e-20 1.198850067773280898e+03 9.423599135022203515e-20 9.238616564889728202e-20 1.543896307817646048e-20 1.514993106141143696e-28 3.261212419048581359e-21 2.496885423214446759e-25 4.930925614665747743e-24 1.320813871886959826e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.919630851276189476e-21 0.000000000000000000e+00 5.271124769550160204e-21 9.396325625841158175e-20 1.200250067694228392e+03 9.226371783465974878e-20 9.248626759828794949e-20 1.573343648049353638e-20 1.506614346353292457e-28 3.259538806151498677e-21 2.488534251733890252e-25 4.919798748158583246e-24 1.320697205348568362e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.989894419438523441e-21 0.000000000000000000e+00 5.276082699139742345e-21 9.411363281946804599e-20 1.201600058255657814e+03 9.045971125989013553e-20 9.258280177590731026e-20 1.621612903141789677e-20 1.498827032377889406e-28 3.257888817687529486e-21 2.480481407980443992e-25 4.909069344150622901e-24 1.320584706252477102e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.923922678384329248e-21 0.000000000000000000e+00 5.280876519541557802e-21 9.428775455549048441e-20 1.202950067542290071e+03 8.995781547151127128e-20 9.267934509031559702e-20 1.645803508384849435e-20 1.491039610387632208e-28 3.256238806337200997e-21 2.472428468151196823e-25 4.898339791319203209e-24 1.320472205595973704e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.926001587225370646e-21 0.000000000000000000e+00 5.285670406436622183e-21 9.442471332952978899e-20 1.204300058125050555e+03 9.145782443288311717e-20 9.277589484050201299e-20 1.442539280135763934e-20 1.483285985394449783e-28 3.254602708350633763e-21 2.464375655667450019e-25 4.887610387141709395e-24 1.320359706498144969e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.941680400737724823e-21 0.000000000000000000e+00 5.290464226914183863e-21 9.418768650699719112e-20 1.205650067391032280e+03 9.157721251890050382e-20 9.287245367610367923e-20 1.389638666804062724e-20 1.475612248514132635e-28 3.252990197282933662e-21 2.456322747667060631e-25 4.876880834474414427e-24 1.320247205843402367e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.956009871708591315e-21 0.000000000000000000e+00 5.295258113735918461e-21 9.420412415917002384e-20 1.207050067312868350e+03 9.121355040083673566e-20 9.297259623118775306e-20 1.524614297915155509e-20 1.467654354221590646e-28 3.251317975154073860e-21 2.447971658594877216e-25 4.865753967960187414e-24 1.320130539305041371e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.955944949861133504e-21 0.000000000000000000e+00 5.300229517521683495e-21 9.451139770442925690e-20 1.208400057927837224e+03 9.265428804050359669e-20 9.306916944341829306e-20 1.551585297240727519e-20 1.460039675604111584e-28 3.249737770516297500e-21 2.439918894788056229e-25 4.855024563526709134e-24 1.320020292584957647e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.980976060164038827e-21 0.000000000000000000e+00 5.305023338113617578e-21 9.465150136230985880e-20 1.209750067162634878e+03 9.401250438508712048e-20 9.316575166382752773e-20 1.500045456244255006e-20 1.452479623889244739e-28 3.248168840865046044e-21 2.431866036327269135e-25 4.844295011107258335e-24 1.319910832491038369e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.980980340121487090e-21 0.000000000000000000e+00 5.309817224824617223e-21 9.466364704862258400e-20 1.211150067085000046e+03 9.512438391033833227e-20 9.326591839519128714e-20 1.382379636227691609e-20 1.444639624323999497e-28 3.246538806896110895e-21 2.423514998950999240e-25 4.833168144588825991e-24 1.319798597089701216e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.011873851252693887e-21 0.000000000000000000e+00 5.314788628612261544e-21 9.458463350835157503e-20 1.212500057731957440e+03 9.341256103945497034e-20 9.336251484858828012e-20 1.457728731203566007e-20 1.437163892088992406e-28 3.244888818327607342e-21 2.415462285311836617e-25 4.822438739901110323e-24 1.319723597687659859e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.969843244613592437e-21 0.000000000000000000e+00 5.319582449317786373e-21 9.479127119194181178e-20 1.213850066935781115e+03 9.397804159781194455e-20 9.345912023385039002e-20 1.477399557408269329e-20 1.429717525533164867e-28 3.243238807078489481e-21 2.407409477898628777e-25 4.811709187727833020e-24 1.319648597254691336e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.044557069623641170e-21 0.000000000000000000e+00 5.324383775677549329e-21 9.492020700661655780e-20 1.215250066858669243e+03 9.184011236103669788e-20 9.355931091432236936e-20 1.368028558161970904e-20 1.421995420695339910e-28 3.241542975696589557e-21 2.399058493804686975e-25 4.800582321205244569e-24 1.319555539943466517e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.032426029780765190e-21 0.000000000000000000e+00 5.329401211758175764e-21 9.485466092980610675e-20 1.216650066781734949e+03 9.234346736295496297e-20 9.365950972100838741e-20 1.472505178448607767e-20 1.414372794461505109e-28 3.239870753566260858e-21 2.390707528279664846e-25 4.789455454681244789e-24 1.319438873405130724e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.012918494020088388e-21 0.000000000000000000e+00 5.334418647839438659e-21 9.510903297175316742e-20 1.218000057471263062e+03 9.392481911216665777e-20 9.375613700943039187e-20 1.392012927176230409e-20 1.407026003024809971e-28 3.238258264687102221e-21 2.382654884387154088e-25 4.778726049655187317e-24 1.319326374298588473e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.027302356247066144e-21 0.000000000000000000e+00 5.339256856673176330e-21 9.508384203158573946e-20 1.219350066633860479e+03 9.289932554688450780e-20 9.385277312877094246e-20 1.565302620259410898e-20 1.399700169298578733e-28 3.236679652290378345e-21 2.374602147929919149e-25 4.767996497809566575e-24 1.319216238665114019e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.036325906317376146e-21 0.000000000000000000e+00 5.344095131712234141e-21 9.544856197085702567e-20 1.220750066557442551e+03 9.163637952150203937e-20 9.395299558418784165e-20 1.488989403555213101e-20 1.392199117076439229e-28 3.235052625352161158e-21 2.366251237918903435e-25 4.756869631281462851e-24 1.319102725276481882e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.010946116744301438e-21 0.000000000000000000e+00 5.349112567795347735e-21 9.542421410637444458e-20 1.222150066481199246e+03 9.319984727722817523e-20 9.405322606409401268e-20 1.465069791784883274e-20 1.384698064853364330e-28 3.233425598413741597e-21 2.357900347259990607e-25 4.745742764751971309e-24 1.318989211887856140e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.021158303201477502e-21 0.000000000000000000e+00 5.354130003879087255e-21 9.548656188679485187e-20 1.223550066405130792e+03 9.515556970994472844e-20 9.415346454286220115e-20 1.561410500457843362e-20 1.377332991432044891e-28 3.231798571475118535e-21 2.349549476159536862e-25 4.734615898221089745e-24 1.318875698499236416e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.039761647412401933e-21 0.000000000000000000e+00 5.359147439963453455e-21 9.573870311193720252e-20 1.224950066329236279e+03 9.440845941591195999e-20 9.425371099497213806e-20 1.469066397245471847e-20 1.370124786694598872e-28 3.230171544536293100e-21 2.341198624826849530e-25 4.723489031688826241e-24 1.318762185110623086e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.980229337684259964e-21 0.000000000000000000e+00 5.364164876048443325e-21 9.568890896518507383e-20 1.226350066253514797e+03 9.407977706159035995e-20 9.435396539500997411e-20 1.542438050047079765e-20 1.362916581956262075e-28 3.228523531974968398e-21 2.332847793474232533e-25 4.712362165155187408e-24 1.318647207610364749e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.017090167625049279e-21 0.000000000000000000e+00 5.369182312134053104e-21 9.590469044117309776e-20 1.227700057017185372e+03 9.401489320738254390e-20 9.445064612801666779e-20 1.506756843753504181e-20 1.355919703510635691e-28 3.226911043007250838e-21 2.324795279881280770e-25 4.701632759539862699e-24 1.318534708497785347e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.978083371995824702e-21 0.000000000000000000e+00 5.374020863392376658e-21 9.594171632293614459e-20 1.229050066107967950e+03 9.345103857240552061e-20 9.454733551779749238e-20 1.499452824417404839e-20 1.348899656238566276e-28 3.225298532148815815e-21 2.316742675945110071e-25 4.690903208265009851e-24 1.318422207857968137e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.029016649497466294e-21 0.000000000000000000e+00 5.378910410913094589e-21 9.602781364244820681e-20 1.230450066032750556e+03 9.353743540275002276e-20 9.464761304871360777e-20 1.493398824150026692e-20 1.341619656629696835e-28 3.223663436772749358e-21 2.308391904355903761e-25 4.679776341727364052e-24 1.318339214389009407e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.987761504495171047e-21 0.000000000000000000e+00 5.383981018368972765e-21 9.611562932338609142e-20 1.231850065957704146e+03 9.389392580826364499e-20 9.474789842873749480e-20 1.665926761904590522e-20 1.334583259616824184e-28 3.222036409832938388e-21 2.300041153610861745e-25 4.668649475188360557e-24 1.318263538796616884e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.991078832207594962e-21 0.000000000000000000e+00 5.389051625825470851e-21 9.649759272214646049e-20 1.233250065882828267e+03 9.384670837117054624e-20 9.484819163297198301e-20 1.410661253568578648e-20 1.327576080504408192e-28 3.220409382892929183e-21 2.291690423937862327e-25 4.657522608648000835e-24 1.318181104673927273e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.002855229886935531e-21 0.000000000000000000e+00 5.394122233282585836e-21 9.618941749329367638e-20 1.234650065808122008e+03 9.352054110414349710e-20 9.494849263662313178e-20 1.528250854960757312e-20 1.320581214483091869e-28 3.218782355952723248e-21 2.283339715568119278e-25 4.646395742106292968e-24 1.318067591285343096e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.977579283168379165e-21 0.000000000000000000e+00 5.399192840740315463e-21 9.646679027257212493e-20 1.236050065733585143e+03 9.582926022973398221e-20 9.504880141499978495e-20 1.703572424564795420e-20 1.313688907157734984e-28 3.217155329012320205e-21 2.274989028736235096e-25 4.635268875563239160e-24 1.317954077896765501e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.016778633456228623e-21 0.000000000000000000e+00 5.404263448198658228e-21 9.686030269367044663e-20 1.237450065659216989e+03 9.288373397540951044e-20 9.514911794351293288e-20 1.538964244414327534e-20 1.306796599831547409e-28 3.215551241490886062e-21 2.266638363680272641e-25 4.624142009018843819e-24 1.317842164931111022e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.978531318267809743e-21 0.000000000000000000e+00 5.409334055657612626e-21 9.668175549479662253e-20 1.238850065585016637e+03 9.524676574524287064e-20 9.524944219767530320e-20 1.485225368958548178e-20 1.299936604905509470e-28 3.213967031048534125e-21 2.258287720641817585e-25 4.613015142473115762e-24 1.317731638736982267e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.996732516088816809e-21 0.000000000000000000e+00 5.414404663117174896e-21 9.669747333497677824e-20 1.240250065510984086e+03 9.496852449099696377e-20 9.534977415310079501e-20 1.640183425548819557e-20 1.293144810392867143e-28 3.212382820605991852e-21 2.249937099866033969e-25 4.601888275926053518e-24 1.317621112542859530e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.973622118917800047e-21 0.000000000000000000e+00 5.419475270577344286e-21 9.704543025281780753e-20 1.241650065437118201e+03 9.629824770152873048e-20 9.545011378555215775e-20 1.496867181158825044e-20 1.286353015879416099e-28 3.210794520314622862e-21 2.242600296355751370e-25 4.591801377723367671e-24 1.317508132442132664e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.010994244099949875e-21 0.000000000000000000e+00 5.424545878038117785e-21 9.691410723188187661e-20 1.243050065363418980e+03 9.509481249314770582e-20 9.555046107081398812e-20 1.542794038178001563e-20 1.279615072211761416e-28 3.209205331209092008e-21 2.235653706652693944e-25 4.582114758894522834e-24 1.317394619053587983e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.969090029279323323e-21 0.000000000000000000e+00 5.429638183061428680e-21 9.708337216132487504e-20 1.244450065289885515e+03 9.380273988154738235e-20 9.565081598478197285e-20 1.610323644862300550e-20 1.272923790511931851e-28 3.207609383582024979e-21 2.228707123265901946e-25 4.572428140064531891e-24 1.317281105665050450e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.984554457478204828e-21 0.000000000000000000e+00 5.434735703116970299e-21 9.729249640896251456e-20 1.245850065216517123e+03 9.250311367156203612e-20 9.575117850346962948e-20 1.447207604901345897e-20 1.266232508811313298e-28 3.205982356640264005e-21 2.221760546254630394e-25 4.562741521233397778e-24 1.317167592276520063e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.004695063790894111e-21 0.000000000000000000e+00 5.439833223173112267e-21 9.713584205753727880e-20 1.247300074828293646e+03 9.511352288443541408e-20 9.585513408386824095e-20 1.506402096615873249e-20 1.259369903374204463e-28 3.204297210334685855e-21 2.214565835924166500e-25 4.552708884699942915e-24 1.317050024052927452e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.006317162010551145e-21 0.000000000000000000e+00 5.445112832790959618e-21 9.732848221884430701e-20 1.248750065065063609e+03 9.353450948728574652e-20 9.595909638070827278e-20 1.544441797753097066e-20 1.252528923795597289e-28 3.202638084268480617e-21 2.207371228701068736e-25 4.542676382222424927e-24 1.316934271192989835e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.005834832288766726e-21 0.000000000000000000e+00 5.450392371862742414e-21 9.749063002071359853e-20 1.250150064992199304e+03 9.596864619237891262e-20 9.605948210781242517e-20 1.379055028790329546e-20 1.245927390343935317e-28 3.201053873824616901e-21 2.200424671650176152e-25 4.532989763387804005e-24 1.316823744998915059e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.000847860705410443e-21 0.000000000000000000e+00 5.455489891920720034e-21 9.734142656086678734e-20 1.251550064919498254e+03 9.392439071414430064e-20 9.615987534299022005e-20 1.598355283253475238e-20 1.239422775297100123e-28 3.199469663380567738e-21 2.193478121223858664e-25 4.523303144552053139e-24 1.316713218804847429e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.966108017268121007e-21 0.000000000000000000e+00 5.460587411979291984e-21 9.777378981687375642e-20 1.252950064846959549e+03 9.385273767594317368e-20 9.626027606275027136e-20 1.463436537407271679e-20 1.232918160249510918e-28 3.197881007471018873e-21 2.186531577485265575e-25 4.513616525715178941e-24 1.316600025334396069e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.985130844802444553e-21 0.000000000000000000e+00 5.465684932038455254e-21 9.766227662813548318e-20 1.254350064774582961e+03 9.486986406675048838e-20 9.636068424369751362e-20 1.563096939401580390e-20 1.226478711105360032e-28 3.196291818363986772e-21 2.179585040498350205e-25 4.503929906877182881e-24 1.316486511945908565e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.994057138389307814e-21 0.000000000000000000e+00 5.470782452098208341e-21 9.791598471970908902e-20 1.255800074321811508e+03 9.636878047073951866e-20 9.646468696207614257e-20 1.511864016537521041e-20 1.220011668524720731e-28 3.194647284320055370e-21 2.172390372348957794e-25 4.493897270790335790e-24 1.316369797370426058e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.028070354764444787e-21 0.000000000000000000e+00 5.476062061481030549e-21 9.793957493568425261e-20 1.257250064625172399e+03 9.639194541870142904e-20 9.656869625298742033e-20 1.438788904131475918e-20 1.213544711771731041e-28 3.193006505818883999e-21 2.165195807069680020e-25 4.483864767852074710e-24 1.316255324571946405e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.030957743909109651e-21 0.000000000000000000e+00 5.481376610689749649e-21 9.793235622472238040e-20 1.258650064553289894e+03 9.757920773896556623e-20 9.666912720516736005e-20 1.632542856067970491e-20 1.207266375349256009e-28 3.191422295373908735e-21 2.158249291228650793e-25 4.474178149010660165e-24 1.316144798377914134e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.003057884495481399e-21 0.000000000000000000e+00 5.486526638343270189e-21 9.833353269735159418e-20 1.260050064481566551e+03 9.544979421571724981e-20 9.676956552426541995e-20 1.536490700062383550e-20 1.200948426954982017e-28 3.189860455046689636e-21 2.151302782408268465e-25 4.464491530168144329e-24 1.316056642278324684e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.012112274317218539e-21 0.000000000000000000e+00 5.491676665997376783e-21 9.827813577385778974e-20 1.261500073985993367e+03 9.685637716778639181e-20 9.687359935527520258e-20 1.793935605471382107e-20 1.194404794319619901e-28 3.188257812962849414e-21 2.144108143934517927e-25 4.454458894377443203e-24 1.315980326068792776e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.995361039396486456e-21 0.000000000000000000e+00 5.497010658446724244e-21 9.881493609625558645e-20 1.262950064333503178e+03 9.512263131962147457e-20 9.697763966435920823e-20 1.552053316795580367e-20 1.188053221435931563e-28 3.186655192052443763e-21 2.136913608195202885e-25 4.444426391133715223e-24 1.315904010867527700e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.029935367084956530e-21 0.000000000000000000e+00 5.502344580425602156e-21 9.850863979423314885e-20 1.264350064262267551e+03 9.942219555488112375e-20 9.707810046754610072e-20 1.553543885058194509e-20 1.181991221744381912e-28 3.185067494621209785e-21 2.129967121368739089e-25 4.434739772287824983e-24 1.315791918122431312e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.027384932020767920e-21 0.000000000000000000e+00 5.507494608081502272e-21 9.861001855767613983e-20 1.265750064191189495e+03 9.784797986136853781e-20 9.717856854493611161e-20 1.569421294988792584e-20 1.175929222052149772e-28 3.183478305512703896e-21 2.123020641846359593e-25 4.425053153440844472e-24 1.315678404733984809e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.021625637980142904e-21 0.000000000000000000e+00 5.512644635737981672e-21 9.873404069328766452e-20 1.267200073653196569e+03 9.603737996500586799e-20 9.728263309680528142e-20 1.601301724559932443e-20 1.169715684764319138e-28 3.181834127181909367e-21 2.115826034233709430e-25 4.415020517943645919e-24 1.315561903535177823e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.044672306418210449e-21 0.000000000000000000e+00 5.517978628031284421e-21 9.888877427106334111e-20 1.268650064044455348e+03 9.711678159623884885e-20 9.738670403389299531e-20 1.599451789220889907e-20 1.163509725889731446e-28 3.180193348581274247e-21 2.108631529239729692e-25 4.404988014397217858e-24 1.315447430729906446e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.031639999185565431e-21 0.000000000000000000e+00 5.523312550171097102e-21 9.898787743418348015e-20 1.270100073485025405e+03 9.704032563117983089e-20 9.749078406737824998e-20 1.507144040840622770e-20 1.157319691362893504e-28 3.178552548424839752e-21 2.101436937803922840e-25 4.394955379048342447e-24 1.315332956420764772e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.011840364739002370e-21 0.000000000000000000e+00 5.528646542385541295e-21 9.894491096670021672e-20 1.271550063898390135e+03 9.737985046677294640e-20 9.759487043944429494e-20 1.525930103153258701e-20 1.151229731626761752e-28 3.176969161955579695e-21 2.094242448935866844e-25 4.384922875348963469e-24 1.315220609246976263e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.041557666445348404e-21 0.000000000000000000e+00 5.534008858088448255e-21 9.907768368332933390e-20 1.272950063828114253e+03 9.672521584031506557e-20 9.769537557299929498e-20 1.496148258036852650e-20 1.145349731921920501e-28 3.175461469723569423e-21 2.087296008134678095e-25 4.375236256496433155e-24 1.315112917057973374e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.042847943087975271e-21 0.000000000000000000e+00 5.539218095689669697e-21 9.913159447255539784e-20 1.274400073237076867e+03 9.804909922472765381e-20 9.779947838017543187e-20 1.613878014975186502e-20 1.139284696066131170e-28 3.173899919053757271e-21 2.080101441299942574e-25 4.365203621366249652e-24 1.315001377841765434e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.071753949852032491e-21 0.000000000000000000e+00 5.544613412771422199e-21 9.941993262268795114e-20 1.275850063683033341e+03 9.634098883155508371e-20 9.790358745751893391e-20 1.655199137018781736e-20 1.133267235715411952e-28 3.172297298034542221e-21 2.072906976967755626e-25 4.355171117441367511e-24 1.314886905032278828e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.020888395607987383e-21 0.000000000000000000e+00 5.550008659294025107e-21 9.958836986169435872e-20 1.277300073070798362e+03 1.011473661176899444e-19 9.800770550226848351e-20 1.873308781466754319e-20 1.127249696756187081e-28 3.170694656079644137e-21 2.065712427152481643e-25 4.345138482457851173e-24 1.314772430727408431e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.082391023390943919e-21 0.000000000000000000e+00 5.555403976296904008e-21 1.000787155031915166e-19 1.278750063538610448e+03 9.754619062993407285e-20 9.811182977153854745e-20 1.586040484997031114e-20 1.121283240127083630e-28 3.169092035036272960e-21 2.058517979802953618e-25 4.335105978381749765e-24 1.314657957916238140e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.093780266593230974e-21 0.000000000000000000e+00 5.560799222900828555e-21 9.968418428567915129e-20 1.280200072905273146e+03 9.825282451397164749e-20 9.821596295699084468e-20 1.524824256715427091e-20 1.115352701817433143e-28 3.167489393104698188e-21 2.051323447363224587e-25 4.325073343544240846e-24 1.314543483613075877e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.066857380881181403e-21 0.000000000000000000e+00 5.566194539825188194e-21 9.969035642398646356e-20 1.281650063394841027e+03 9.660445169389588764e-20 9.832010232170876830e-20 1.690131115806990252e-20 1.109422240715100604e-28 3.165886772037280723e-21 2.044129017358405219e-25 4.315040839317610774e-24 1.314429010800229990e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.098147308025827524e-21 0.000000000000000000e+00 5.571589786510064242e-21 1.000604059798867711e-19 1.283100072740496444e+03 9.729501436738807090e-20 9.842425055179866827e-20 1.718884825218373780e-20 1.103563706855799867e-28 3.164315306279465389e-21 2.036934502660397961e-25 4.305008204625450996e-24 1.314316763364318407e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.072009259023209407e-21 0.000000000000000000e+00 5.576985103356257456e-21 1.002108475248816070e-19 1.284550063251720985e+03 9.827697680457092763e-20 9.852840491628714083e-20 1.655384738664768073e-20 1.097720245095564776e-28 3.162753778036608278e-21 2.029740090372602358e-25 4.294975700248978456e-24 1.314205225750176295e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.067057759056567123e-21 0.000000000000000000e+00 5.582380350121715616e-21 1.002063397852704459e-19 1.286000072576462571e+03 9.722602066334188600e-20 9.863256809574665309e-20 1.566701533490261690e-20 1.091892401825798917e-28 3.161189393468120394e-21 2.022545593792951920e-25 4.284943065701522033e-24 1.314093484113009647e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.142000499722817726e-21 0.000000000000000000e+00 5.587784788967423925e-21 1.001695479880073304e-19 1.287450063109245548e+03 1.002176250449586381e-19 9.873673736512166643e-20 1.782589927692196154e-20 1.086276340932971124e-28 3.159586772352939114e-21 2.015351199605127671e-25 4.274910561175886606e-24 1.313979011296834572e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.132761978890307320e-21 0.000000000000000000e+00 5.593213910563263168e-21 1.006319000202872678e-19 1.288900072413166981e+03 9.768571165977055303e-20 9.884091539947204664e-20 1.622597900590083158e-20 1.080660207336319286e-28 3.157984130490710233e-21 2.008156721531293983e-25 4.264877926772484811e-24 1.313864536998750068e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.101737280290826482e-21 0.000000000000000000e+00 5.598643102442867344e-21 1.004623169503376799e-19 1.290350062967410395e+03 9.794439236716690109e-20 9.894509947963472201e-20 1.680802591686512716e-20 1.075031253797425390e-28 3.156399932188942945e-21 2.000962345837408479e-25 4.254845422098363877e-24 1.313751380096473546e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.144802043260823803e-21 0.000000000000000000e+00 5.604072224119059995e-21 1.006623875988055504e-19 1.291800072250604444e+03 9.684512482234564757e-20 9.904929227517834688e-20 1.799068795015522033e-20 1.069361717500136738e-28 3.154838383730118305e-21 1.993767886668074912e-25 4.244812787838375332e-24 1.313639841038436553e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.170985827831739293e-21 0.000000000000000000e+00 5.609501415921055213e-21 1.009701414031017766e-19 1.293300072166806558e+03 9.705175048790957532e-20 9.915708496015294209e-20 1.579549407116492606e-20 1.063496717827786422e-28 3.153222999204977786e-21 1.986325400819151910e-25 4.234434267698062590e-24 1.313524456551166231e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.186385977563364663e-21 0.000000000000000000e+00 5.615117784962568383e-21 1.007092284043021529e-19 1.294750062753425709e+03 9.983808521310409370e-20 9.926129133389929609e-20 1.650480522949752679e-20 1.057935373435879656e-28 3.151661470880926177e-21 1.979131053963041390e-25 4.224401762799933575e-24 1.313412918931366325e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.134834705539580971e-21 0.000000000000000000e+00 5.620546906759984030e-21 1.009235255028157204e-19 1.296200072005347238e+03 9.897017640467293468e-20 9.936550634853707008e-20 1.344460833283240586e-20 1.052474850789619003e-28 3.150099922455779732e-21 1.971936624263891879e-25 4.214369128756319744e-24 1.313301379875795236e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.174440425689194463e-21 0.000000000000000000e+00 5.625976098444887222e-21 1.005732907530024115e-19 1.297700071922116649e+03 9.815104030723979638e-20 9.947332194743115584e-20 1.676477499911315816e-20 1.046826070615248185e-28 3.148484537930028332e-21 1.964494169075533818e-25 4.203990608612082321e-24 1.313185995388544287e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.196435849633234584e-21 0.000000000000000000e+00 5.631592467488524933e-21 1.011778720750952302e-19 1.299150062540890531e+03 9.743079679253617668e-20 9.957755040261116988e-20 1.836199264277822596e-20 1.041427085214259291e-28 3.146923009571348728e-21 1.957299852032225617e-25 4.193958103491474102e-24 1.313074457766331513e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.166788252161321476e-21 0.000000000000000000e+00 5.637021589406335276e-21 1.015559784617488293e-19 1.300600071761749177e+03 9.709616499483900721e-20 9.968178742513665973e-20 1.734137649841628435e-20 1.036051441273515156e-28 3.145361461179654784e-21 1.951191315030201986e-25 4.185081931970599311e-24 1.312962918713210531e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.190810339798552350e-21 0.000000000000000000e+00 5.642454577202667057e-21 1.014800446195718276e-19 1.302100071679080656e+03 9.929832623348303734e-20 9.978962572036767464e-20 1.627784726563511424e-20 1.030490465970237795e-28 3.143764027209171677e-21 1.945010255879534606e-25 4.176046794518986716e-24 1.312847534225978954e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.197695805055432144e-21 0.000000000000000000e+00 5.648135057571093468e-21 1.014103871952910301e-19 1.303600071596602447e+03 9.932583404035321139e-20 9.989747170370909379e-20 1.697479368476214120e-20 1.024883732228706888e-28 3.142187104218956407e-21 1.938829200043046126e-25 4.167011657066228749e-24 1.312732149738753959e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.175165277125161287e-21 0.000000000000000000e+00 5.653815537940241352e-21 1.016299302939760056e-19 1.305050062258149637e+03 9.884256952428875850e-20 1.000017294397744664e-19 1.662649435441126161e-20 1.019460767154520337e-28 3.140662755061945526e-21 1.932854220734489912e-25 4.158277746631126725e-24 1.312620612113332368e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.197692704978831240e-21 0.000000000000000000e+00 5.659306633901082104e-21 1.016760607705967658e-19 1.306500071437681527e+03 9.821979816229518503e-20 1.001059956458551349e-19 1.657476107379937551e-20 1.014105463233290657e-28 3.139107615374804535e-21 1.926879168275318813e-25 4.149543724654328189e-24 1.312509073063471925e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.165833563806308572e-21 0.000000000000000000e+00 5.664797799989293251e-21 1.017691203963226986e-19 1.308000071355757655e+03 1.003788032594742665e-19 1.002138640378910673e-19 1.486115470401850194e-20 1.008834034949766158e-28 3.137492230847645552e-21 1.920698122345447646e-25 4.140508587198230348e-24 1.312393688576267243e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.208111732749964618e-21 0.000000000000000000e+00 5.670478280360540097e-21 1.016125053558772659e-19 1.309500071274021366e+03 9.849010909690369412e-20 1.003217400208111881e-19 1.793715098732636118e-20 1.003562606665582264e-28 3.135876846320284571e-21 1.914517079857249680e-25 4.131473449741003298e-24 1.312278304089069520e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.247422026342561370e-21 0.000000000000000000e+00 5.676158760732497130e-21 1.022154983040276103e-19 1.311000071192472205e+03 9.957805602945741993e-20 1.004296235701543333e-19 1.517028767465431873e-20 9.982748698256840983e-29 3.134261461792721969e-21 1.908336040844177373e-25 4.122438312282648508e-24 1.312162919601878944e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.251096153526498779e-21 0.000000000000000000e+00 5.681839241105162845e-21 1.018731928316391274e-19 1.312450061907118879e+03 9.972826533945530207e-20 1.005339175083589632e-19 1.524328206309602887e-20 9.931397807582035021e-29 3.132699933330794840e-21 1.902361077737974305e-25 4.113704401527706227e-24 1.312051381972475154e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.215624464311977904e-21 0.000000000000000000e+00 5.687330337267090996e-21 1.019856790842808315e-19 1.313900071035338215e+03 9.845844072403894191e-20 1.006382197967638982e-19 1.594794719976046179e-20 9.880046264797290780e-29 3.131179927188778231e-21 1.896386042065850686e-25 4.104970379859984827e-24 1.311941381523182474e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.243255717762610946e-21 0.000000000000000000e+00 5.692821503160981830e-21 1.021974913308199222e-19 1.315400070954333842e+03 1.005571700729195378e-19 1.007461254008117569e-19 1.637917508124722990e-20 9.827275563648209222e-29 3.129642427271807860e-21 1.890205013443621534e-25 4.095935242398348939e-24 1.311828881648191542e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.245996818973629652e-21 0.000000000000000000e+00 5.698501983535711149e-21 1.023722430496228613e-19 1.316900070873514323e+03 9.896565507653715528e-20 1.008540384760658553e-19 1.633960513194224184e-20 9.774738981113008962e-29 3.128104927354647906e-21 1.884023988432383605e-25 4.086900104935599269e-24 1.311716381773207192e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.232774173173044979e-21 0.000000000000000000e+00 5.704244560673263507e-21 1.024718508325560400e-19 1.318400070792878523e+03 1.017689949007435497e-19 1.009619589985694665e-19 1.549866640359764220e-20 9.722202398571373939e-29 3.126533258910050580e-21 1.877842967067804889e-25 4.077864967471743166e-24 1.311601381764733488e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.220870310999284886e-21 0.000000000000000000e+00 5.709995903663385137e-21 1.024472603322749603e-19 1.319900070712425759e+03 9.974169242336355881e-20 1.010698869444664213e-19 1.748062778563718844e-20 9.670426833025726710e-29 3.124956335917706255e-21 1.871661949386025868e-25 4.068829830006785036e-24 1.311485997277584290e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.267911065077234445e-21 0.000000000000000000e+00 5.715747246654207927e-21 1.028740229134989792e-19 1.321400070632156030e+03 9.935030072939704823e-20 1.011778222900008432e-19 1.740828176005033006e-20 9.618768299204772563e-29 3.123379925836235881e-21 1.865480935423659975e-25 4.059794692540724146e-24 1.311371382156228802e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.192661221185164444e-21 0.000000000000000000e+00 5.721498589645732627e-21 1.029649899965567374e-19 1.322900070552067973e+03 1.000922963911525741e-19 1.012857650115163782e-19 1.599745718901717679e-20 9.567369090274319431e-29 3.121804925920328485e-21 1.859299925217814951e-25 4.050759555073568577e-24 1.311258882281272664e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.195209499422060753e-21 0.000000000000000000e+00 5.727249932637954725e-21 1.028425548462920165e-19 1.324400070472161588e+03 1.027507250354569285e-19 1.013937150854558579e-19 1.793083537767232077e-20 9.517654807208360540e-29 3.120229926004230376e-21 1.853118918806087559e-25 4.041724417605319063e-24 1.311146382406323110e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.186963691320313141e-21 0.000000000000000000e+00 5.733001275630872715e-21 1.032669029299693321e-19 1.325900070392436191e+03 1.002418049972467456e-19 1.015016724883607452e-19 1.601423623416700292e-20 9.467940524136402971e-29 3.118677427847752774e-21 1.846937916226580575e-25 4.032689280135979279e-24 1.311033882531380702e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.222605358200075397e-21 0.000000000000000000e+00 5.738752618624484341e-21 1.030594679433376061e-19 1.327400070312890648e+03 1.003096741481765862e-19 1.016096371968705090e-19 1.586849006401566066e-20 9.418464369778907594e-29 3.117139927929287174e-21 1.840756917517910367e-25 4.023654142665555835e-24 1.310921382656445066e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.199116473417922429e-21 0.000000000000000000e+00 5.744503961618786594e-21 1.031425922960019136e-19 1.328900070233524730e+03 1.002487608911573701e-19 1.017176091877223350e-19 1.514818853037123581e-20 9.369464372371526137e-29 3.115602428010637258e-21 1.834575922719210336e-25 4.014619005194050937e-24 1.310808882781516200e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.219779557232871134e-21 0.000000000000000000e+00 5.750255304613776464e-21 1.031418286863539776e-19 1.330400070154337755e+03 1.025937212163181620e-19 1.018255884377504518e-19 1.520308944324006792e-20 9.320464374958298464e-29 3.114064928091803776e-21 1.828394931870143543e-25 4.005583867721468257e-24 1.310661381189807718e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.220458475554536565e-21 0.000000000000000000e+00 5.756006647609453198e-21 1.032566875378788595e-19 1.331900070075329268e+03 1.004014826907540618e-19 1.019335749238857455e-19 1.688817745561173909e-20 9.271845363289398509e-29 3.112527428172787481e-21 1.822213945010912125e-25 3.996548730247810000e-24 1.310511381356601518e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.191974917438683910e-21 0.000000000000000000e+00 5.761787851321124379e-21 1.036235512350601116e-19 1.333400069996498587e+03 1.005829089857025936e-19 1.020415686231551218e-19 1.603836935742673800e-20 9.223559651541281683e-29 3.110979926503676275e-21 1.816032962182264410e-25 3.987513592773080574e-24 1.310371383262727777e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.260901407076032019e-21 0.000000000000000000e+00 5.767581238025042452e-21 1.035979081741315428e-19 1.334900069917844803e+03 1.008029499107591009e-19 1.021495695126811450e-19 1.890745956040044347e-20 9.175273939787471102e-29 3.109404926586262741e-21 1.809851983425508234e-25 3.978478455297286591e-24 1.310258883387845931e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.215280190263296907e-21 0.000000000000000000e+00 5.773374624729643628e-21 1.041849903464706214e-19 1.336400069839367688e+03 1.017930096558857828e-19 1.022575775696815566e-19 1.764776028880549181e-20 9.127512070808623920e-29 3.107829926668663761e-21 1.803671008782512776e-25 3.969443317820427316e-24 1.310146383512971044e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.310443191157339204e-21 0.000000000000000000e+00 5.779168011434927155e-21 1.040740573977372696e-19 1.337900069761066561e+03 1.025198336874329669e-19 1.023655927714686971e-19 1.681878988589289895e-20 9.079940644720460044e-29 3.106277428494906580e-21 1.797490038295726470e-25 3.960408180342508626e-24 1.310033883638103304e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.218406545309048915e-21 0.000000000000000000e+00 5.784961398140890024e-21 1.040394741086077512e-19 1.339450079323600676e+03 1.010520727227810878e-19 1.024772166564615682e-19 1.747146204477466796e-20 9.030783198594378086e-29 3.104688668693309144e-21 1.791103000134990224e-25 3.951071813528754073e-24 1.309917633044170769e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.237247557267932906e-21 0.000000000000000000e+00 5.790947934982525738e-21 1.042577395499372140e-19 1.341000069599799417e+03 1.002565007137436533e-19 1.025888467325853108e-19 1.557767218961168045e-20 8.982340682977694554e-29 3.103099928660205589e-21 1.784716045979136431e-25 3.941735562884799494e-24 1.309801383896733685e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.377696201466770766e-21 0.000000000000000000e+00 5.796934397335357940e-21 1.040732859172317342e-19 1.342500069522034437e+03 1.015092768362550394e-19 1.026968837045706804e-19 1.514122359164001603e-20 8.935483542549782943e-29 3.101562428739914870e-21 1.778535088508966184e-25 3.932700425403651134e-24 1.309688884021888703e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.285368890098273124e-21 0.000000000000000000e+00 5.802727784043391936e-21 1.041118513941239548e-19 1.344000069444442715e+03 1.025495697751927042e-19 1.028049277300446117e-19 1.743411506347313303e-20 8.888769292328097937e-29 3.100024928819446228e-21 1.772354135373769310e-25 3.923665287921459523e-24 1.309576384147051431e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.286786892878216821e-21 0.000000000000000000e+00 5.808521170752094741e-21 1.045764894896263131e-19 1.345500069367024253e+03 1.020848925686110331e-19 1.029129787867917313e-19 1.729252191321004872e-20 8.842626437566780309e-29 3.098487428898800416e-21 1.766173186619066140e-25 3.914630150438223926e-24 1.309463884272221495e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.365634064375040136e-21 0.000000000000000000e+00 5.814314557461467108e-21 1.046627577833367526e-19 1.347050078876060297e+03 1.007448998336487797e-19 1.030246395994663994e-19 1.659013483913110018e-20 8.794945192669766208e-29 3.096898669152038193e-21 1.759786171378096934e-25 3.905293783946710578e-24 1.309347633682408644e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.286713649840613245e-21 0.000000000000000000e+00 5.820339549739755595e-21 1.046559429408841613e-19 1.348600069207571551e+03 1.033904982602180274e-19 1.031363064904621934e-19 1.728304666244572613e-20 8.747531230741398945e-29 3.095309929062238947e-21 1.753399239939685106e-25 3.895957532969584900e-24 1.309231384530930493e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.335225013404142210e-21 0.000000000000000000e+00 5.826401510605389388e-21 1.048801105762903169e-19 1.350100069130679913e+03 1.029765429264407487e-19 1.032443789722181710e-19 1.592269782585979446e-20 8.701959804506009663e-29 3.093799930869319997e-21 1.747218304909150544e-25 3.886922395483176203e-24 1.309120896975568122e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.285845181865583630e-21 0.000000000000000000e+00 5.832267960638965705e-21 1.047692861700131228e-19 1.351600069053959032e+03 1.033686214425769631e-19 1.033524583958447542e-19 1.685943748960169313e-20 8.656388378265433335e-29 3.092299930946040751e-21 1.741037374450941180e-25 3.877887257995738948e-24 1.309011141000154099e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.334616326576056534e-21 0.000000000000000000e+00 5.838134410673209326e-21 1.050243773850853534e-19 1.353150078520487114e+03 1.011879142336732383e-19 1.034641484244960065e-19 1.482241695272159962e-20 8.610527939029491960e-29 3.090748669516500674e-21 1.734650378499005915e-25 3.868550891760269575e-24 1.308897634186821705e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.405522591883380691e-21 0.000000000000000000e+00 5.844196446375260434e-21 1.048301639333286810e-19 1.354700068895940831e+03 1.028654010674418168e-19 1.035758444426729394e-19 1.896436270968351271e-20 8.565253801551124207e-29 3.089159929381660621e-21 1.728263466203941573e-25 3.859214640518460039e-24 1.308781385032132668e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.419100624255204447e-21 0.000000000000000000e+00 5.850258407412751877e-21 1.056059298120352975e-19 1.356200068819739954e+03 1.050619154118232207e-19 1.036839450194295929e-19 1.577899127601738127e-20 8.521439850288527870e-29 3.087622429459766716e-21 1.722082550075345152e-25 3.850179503027890092e-24 1.308668885157356522e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.391590496499363837e-21 0.000000000000000000e+00 5.856124857449029010e-21 1.051863267125871800e-19 1.357750078254463006e+03 1.043224890749203386e-19 1.037956568346160279e-19 1.727144446090029054e-20 8.475869125654375933e-29 3.086065777312719017e-21 1.715695569226172098e-25 3.840843136983996176e-24 1.308553823739542014e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.409908145673386979e-21 0.000000000000000000e+00 5.862186893026692127e-21 1.055314636797501448e-19 1.359300068662790409e+03 1.013819603239600759e-19 1.039073745733764781e-19 1.776360167657417348e-20 8.430255122209310601e-29 3.084553591548497235e-21 1.709308671934388017e-25 3.831506885544173882e-24 1.308440409927747086e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.413708205843265715e-21 0.000000000000000000e+00 5.868248854192751431e-21 1.057233734888938854e-19 1.360850078076200134e+03 1.015609893195823997e-19 1.040191009533806731e-19 1.659472905748795169e-20 8.384904761558970685e-29 3.083041387242731356e-21 1.702989298741627900e-25 3.822246296524293353e-24 1.308326994725358703e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.437685349039316111e-21 0.000000000000000000e+00 5.874310889687057893e-21 1.056445732334887045e-19 1.362400068506555272e+03 1.025073367759523514e-19 1.041308332130289147e-19 1.668693028569324072e-20 8.340928288883780978e-29 3.081499931493444653e-21 1.697680434713642277e-25 3.814118517704532044e-24 1.308184310979537502e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.466864425780322367e-21 0.000000000000000000e+00 5.880401169367809458e-21 1.057706153253626750e-19 1.363900068431212731e+03 1.036578346691232125e-19 1.042389687474501159e-19 1.688791790899439879e-20 8.298370151486524453e-29 3.079999931568787163e-21 1.692542794553902108e-25 3.806252877131203072e-24 1.308037969679078069e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.436852748124747292e-21 0.000000000000000000e+00 5.886347041843831895e-21 1.059079623921788792e-19 1.365450077813173039e+03 1.026682598899074114e-19 1.043507165675083410e-19 1.722855955071600049e-20 8.254597821231157334e-29 3.078449922186826792e-21 1.687233869043914920e-25 3.798124998933760792e-24 1.307890409842972843e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.403576693092598276e-21 0.000000000000000000e+00 5.892491147566956839e-21 1.060716536010583944e-19 1.367000068276028742e+03 1.035438282223363176e-19 1.044624702026441002e-19 1.738053891655855106e-20 8.211198088271196850e-29 3.076899931723971405e-21 1.681925010100715619e-25 3.789997219943574842e-24 1.307776996027310069e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.426619310170619932e-21 0.000000000000000000e+00 5.898635178296355863e-21 1.062076140284003979e-19 1.368550077636912874e+03 1.029949912532417861e-19 1.045742323564398124e-19 1.700363351188692814e-20 8.167797826166441205e-29 3.075349922363087178e-21 1.676616088213953980e-25 3.781869341856651071e-24 1.307663580828887522e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.416871288524459355e-21 0.000000000000000000e+00 5.904779283935936072e-21 1.062564660217573203e-19 1.370100068121546656e+03 1.027793771839920024e-19 1.046860002822931642e-19 1.660205409630895429e-20 8.124816728932297862e-29 3.073799931878453360e-21 1.671307232780943590e-25 3.773741562752266580e-24 1.307550167011673283e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.448385475243449587e-21 0.000000000000000000e+00 5.910923314751661145e-21 1.063046186711556473e-19 1.371650077461449428e+03 1.028028717286050195e-19 1.047977766781548786e-19 1.671279128227015776e-20 8.082137401991718226e-29 3.072249922538550484e-21 1.665998314585085668e-25 3.765613684775363937e-24 1.307436751814827780e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.429990428215579522e-21 0.000000000000000000e+00 5.917067420308073530e-21 1.064315555454952502e-19 1.373200067967762379e+03 1.046957853353966595e-19 1.049095588034275716e-19 1.640859258211166944e-20 8.039458593631845066e-29 3.070699932032237541e-21 1.660689462731470958e-25 3.757485905557298122e-24 1.307323337996069035e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.435210382897581066e-21 0.000000000000000000e+00 5.923211451209733446e-21 1.064948415202388726e-19 1.374750077286777469e+03 1.039958396029609463e-19 1.050213493504522976e-19 1.613423029182577105e-20 7.997244412303346073e-29 3.069180412403143885e-21 1.655380548295945308e-25 3.749358027689925839e-24 1.307209922800793616e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.404798575483188406e-21 0.000000000000000000e+00 5.929355556683348147e-21 1.065621198859088103e-19 1.376350077196931807e+03 1.038017956764742642e-19 1.051367527305185037e-19 1.789589189246334102e-20 7.953783949627525500e-29 3.067619436881041850e-21 1.649900413774648702e-25 3.740968011128086690e-24 1.307092849761302481e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.399101367894936271e-21 0.000000000000000000e+00 5.935697820620193576e-21 1.069565478012316194e-19 1.377900067735924949e+03 1.022692655259025704e-19 1.052485562115088147e-19 1.645921959781963310e-20 7.911780044732144714e-29 3.066107076733977746e-21 1.644591567483848638e-25 3.732840231738654370e-24 1.306979958705749863e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.433742214342572855e-21 0.000000000000000000e+00 5.941850160208831213e-21 1.068374343145023048e-19 1.379450077023449467e+03 1.035545202539103710e-19 1.053603680418334003e-19 1.723915151739230736e-20 7.871197983386049860e-29 3.064593972429489831e-21 1.639282658885952371e-25 3.724712354036411125e-24 1.306869243874577617e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.406477049614450996e-21 0.000000000000000000e+00 5.948045923940516571e-21 1.070695635864323186e-19 1.381000067583874852e+03 1.046893471712281877e-19 1.054721854958894328e-19 1.599783113813964805e-20 7.830616412349458239e-29 3.063080886406217462e-21 1.633973816356658465e-25 3.716584574534593463e-24 1.306758530381074119e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.458957695074487450e-21 0.000000000000000000e+00 5.954241612815435961e-21 1.069894289522431154e-19 1.382550076850744745e+03 1.049882977453713790e-19 1.055840112520003987e-19 1.798180202977207846e-20 7.789984023371092202e-29 3.061568217706590667e-21 1.628664911701907029e-25 3.708456696940657330e-24 1.306628214260875746e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.389234831444695017e-21 0.000000000000000000e+00 5.960437376464559862e-21 1.074113649640760047e-19 1.384150076761909531e+03 1.052847434778381821e-19 1.056994508632036261e-19 1.687963085803277399e-20 7.747863095477172921e-29 3.060007242183502721e-21 1.623184787187197102e-25 3.700066680373520374e-24 1.306472116874941983e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.438454878612716334e-21 0.000000000000000000e+00 5.966832964865275874e-21 1.073483551595345237e-19 1.385700067354644716e+03 1.048707842159889815e-19 1.058112893333932524e-19 1.704163538673339624e-20 7.707058691966097334e-29 3.058495056239370871e-21 1.617875950505873716e-25 3.691938900702277242e-24 1.306320898441741548e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.445799098240805348e-21 0.000000000000000000e+00 5.973028653869346169e-21 1.074846471265855715e-19 1.387250076590374647e+03 1.044075486187995264e-19 1.059231360346823881e-19 1.632291487251200199e-20 7.666975330116862020e-29 3.056982068090348377e-21 1.612567051975141576e-25 3.683811023271631967e-24 1.306204958899262421e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.452617329630883212e-21 0.000000000000000000e+00 5.979224417393995563e-21 1.074838431925028493e-19 1.388850076502139927e+03 1.059597563915100489e-19 1.060385971993518102e-19 1.771576519193297212e-20 7.626393514172998180e-29 3.055420163414577508e-21 1.607086933732154337e-25 3.675421006701346156e-24 1.306090673313164533e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.428874519346916923e-21 0.000000000000000000e+00 5.985620005797112216e-21 1.078170510052119067e-19 1.390400067126964132e+03 1.046784401846103871e-19 1.061504564844738632e-19 1.691882513097843204e-20 7.587080115597911945e-29 3.053907251583449553e-21 1.601778103079812217e-25 3.667293226861836151e-24 1.305979437050729969e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.470493192904186413e-21 0.000000000000000000e+00 5.991815694929449446e-21 1.078011371259625692e-19 1.391950076331762830e+03 1.050782759057381735e-19 1.062623239306034321e-19 1.598715807080168054e-20 7.547439900691487141e-29 3.052395047481207072e-21 1.596469210855023196e-25 3.659165349593387056e-24 1.305866021864060297e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.437147761912680970e-21 0.000000000000000000e+00 5.998011458330459404e-21 1.077680729485153831e-19 1.393550076244122693e+03 1.046967952581081529e-19 1.063778064427977468e-19 1.583142684620127172e-20 7.506360833174154328e-29 3.050834071956953413e-21 1.590989099074846730e-25 3.650775333019982512e-24 1.305748948824664706e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.452879053265151514e-21 0.000000000000000000e+00 6.004407046735953377e-21 1.078599341628730484e-19 1.395150076156683781e+03 1.049425916987457957e-19 1.064932961757075794e-19 1.747563261859522494e-20 7.465281765651654648e-29 3.049295165565063068e-21 1.585508989539756796e-25 3.642385316445522961e-24 1.305633530968451742e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.452586975430075717e-21 0.000000000000000000e+00 6.010887689308712492e-21 1.082274413473328655e-19 1.396750076069444958e+03 1.077158878768446717e-19 1.066087931058661957e-19 1.760339732135989359e-20 7.425811762289129287e-29 3.047771356124338087e-21 1.580028882273125759e-25 3.633995299870014282e-24 1.305519245382389589e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.503817340967365257e-21 0.000000000000000000e+00 6.017372176649124867e-21 1.083642044554672984e-19 1.398300066747716073e+03 1.057560283587780911e-19 1.067206869314297453e-19 1.707584700022837891e-20 7.387625628306266471e-29 3.046295174525984584e-21 1.574720062182885531e-25 3.625867519750241444e-24 1.305408531880712551e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.506112363988729323e-21 0.000000000000000000e+00 6.023653986323515082e-21 1.083903272657318534e-19 1.399850075900987349e+03 1.058702306703037077e-19 1.068325888020953977e-19 1.804069373329122603e-20 7.349529975857850673e-29 3.044818975332393038e-21 1.569411180988175100e-25 3.617739642751990011e-24 1.305263291479594232e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.557963246466028049e-21 0.000000000000000000e+00 6.029935870873474661e-21 1.086590008423797856e-19 1.401450075814333331e+03 1.047532450703371495e-19 1.069481067394103669e-19 1.636128493985873639e-20 7.310693614324817003e-29 3.043295165891110967e-21 1.563931080523412176e-25 3.609349626173414761e-24 1.305110910698219029e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.520024140616070388e-21 0.000000000000000000e+00 6.036420358216256832e-21 1.085054060496905743e-19 1.403050075727876674e+03 1.053512488824400275e-19 1.070636317825422929e-19 1.731396485986131985e-20 7.271857252786993134e-29 3.041771356449641192e-21 1.558450982422343625e-25 3.600959609593805076e-24 1.304969245994172862e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.596995753336255956e-21 0.000000000000000000e+00 6.042904845559839468e-21 1.087703959231283733e-19 1.404650075641616922e+03 1.059720237154276761e-19 1.071791639085138325e-19 1.796610450677775516e-20 7.233198184601195256e-29 3.040247547007983715e-21 1.552970886710001047e-25 3.592569593013162425e-24 1.304854960408164688e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.607718792218481211e-21 0.000000000000000000e+00 6.049389332904220311e-21 1.089904859865814950e-19 1.406250075555553622e+03 1.077787673300040350e-19 1.072947030944450944e-19 1.773667888227845759e-20 7.194798186666714840e-29 3.038723737566139288e-21 1.547490793411770299e-25 3.584179576431489747e-24 1.304740674822164225e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.594073370783310872e-21 0.000000000000000000e+00 6.055873820249396353e-21 1.090663028199507036e-19 1.407850075469685862e+03 1.062956426629403565e-19 1.074102493175533505e-19 1.783509702845493654e-20 7.156398188727541754e-29 3.037198765249834345e-21 1.542010702553399529e-25 3.575789559848791451e-24 1.304628133545717768e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.630932994747567881e-21 0.000000000000000000e+00 6.062358307595365336e-21 1.091978787195127196e-19 1.409450075384013189e+03 1.053980359739711325e-19 1.075258025551522655e-19 1.744822208000956641e-20 7.119024931159165053e-29 3.035673183936173367e-21 1.536530614161003996e-25 3.567399543265070474e-24 1.304516505764056706e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.664470676944878013e-21 0.000000000000000000e+00 6.068842794942125004e-21 1.092508301853681808e-19 1.411050075298534694e+03 1.055136602074418492e-19 1.076413627846516562e-19 1.673825965305283411e-20 7.082189377571514076e-29 3.034147602622326944e-21 1.531050528261072961e-25 3.559009526680330491e-24 1.304404877982402414e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.626241434660812020e-21 0.000000000000000000e+00 6.075403358108931094e-21 1.092522424967821692e-19 1.412650075213249920e+03 1.066399784511884977e-19 1.077569299835568534e-19 1.649525721184103919e-20 7.045353823979403606e-29 3.032623737892142793e-21 1.525570444880474964e-25 3.550619510094575909e-24 1.304290675327739615e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.710365381746603557e-21 0.000000000000000000e+00 6.081983148428297200e-21 1.093330943701166682e-19 1.414250075128157960e+03 1.096859028099351111e-19 1.078725041294682206e-19 1.717696165490088564e-20 7.008180069744688739e-29 3.031099928449373393e-21 1.520090364046467240e-25 3.542229493507809667e-24 1.304176389741775263e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.687514985573693912e-21 0.000000000000000000e+00 6.088562938748456247e-21 1.095511616079786481e-19 1.415850075043258357e+03 1.060781831458868712e-19 1.079880852000806963e-19 1.709334966935399109e-20 6.970943708084168343e-29 3.029589216031260187e-21 1.514610285786700998e-25 3.533839476920034704e-24 1.304049007144991883e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.686683223150725882e-21 0.000000000000000000e+00 6.095142729069406731e-21 1.096521950521851984e-19 1.417450074958550431e+03 1.096024804047632065e-19 1.081036731731832288e-19 1.924393932616121177e-20 6.933761919131388906e-29 3.028103501824203226e-21 1.509130210129229226e-25 3.525449460331254694e-24 1.303896626363734794e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.658500520642231882e-21 0.000000000000000000e+00 6.101722519391145642e-21 1.101205501657589331e-19 1.419050074874033498e+03 1.083663542258998363e-19 1.082192680266583904e-19 1.856871012956987013e-20 6.897107375613050140e-29 3.026617787616969094e-21 1.503650137102513582e-25 3.517059443741472574e-24 1.303744245582497642e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.704032653583891832e-21 0.000000000000000000e+00 6.108302309713669219e-21 1.101204178392775425e-19 1.420650074789707105e+03 1.074929217354059200e-19 1.083348697384817878e-19 1.972157863639314329e-20 6.860452832090347171e-29 3.025130162986319226e-21 1.498170066735430819e-25 3.508669427150692020e-24 1.303621157926244106e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.691749576644172534e-21 0.000000000000000000e+00 6.114882100036976710e-21 1.104338707793589842e-19 1.422250074705570341e+03 1.079575546116675475e-19 1.084504782867217013e-19 1.563296826003246123e-20 6.824225013183377088e-29 3.023641790971562455e-21 1.492689999057285184e-25 3.500279410558916703e-24 1.303509530144660344e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.719510145738209173e-21 0.000000000000000000e+00 6.121461890361064354e-21 1.098930551398870987e-19 1.423850074621622525e+03 1.091441936632848227e-19 1.085660936495384464e-19 1.719778463758280825e-20 6.788811681708089189e-29 3.022153418956630394e-21 1.487209934097809568e-25 3.491889393966151032e-24 1.303397902363083918e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.714189060638630454e-21 0.000000000000000000e+00 6.128041680685929140e-21 1.102405063018838967e-19 1.425450074537863202e+03 1.103261962455065155e-19 1.086817158051897426e-19 1.546045300481250625e-20 6.753398350228628784e-29 3.020665046941522668e-21 1.481930232310144100e-25 3.483735176549603453e-24 1.303286274581514826e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.671093784305528673e-21 0.000000000000000000e+00 6.134621471011568812e-21 1.100954887350345216e-19 1.427050074454291916e+03 1.082727645740388220e-19 1.087973447320336021e-19 1.677298331696468909e-20 6.718287267439865455e-29 3.019176674926240028e-21 1.477372948840362491e-25 3.476431153232900219e-24 1.303174646799953069e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.709857085766044533e-21 0.000000000000000000e+00 6.141238141603415976e-21 1.104033806268369800e-19 1.428650074370907760e+03 1.065665249077829023e-19 1.089129804084831187e-19 1.850830847931543820e-20 6.683442824811342906e-29 3.017688302910783226e-21 1.472815666352432971e-25 3.469127129915344016e-24 1.303050226604876159e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.727596433574713809e-21 0.000000000000000000e+00 6.147880950389412809e-21 1.107950621060620779e-19 1.430300083898480580e+03 1.068905883494056327e-19 1.090322374412263038e-19 1.856563830056500714e-20 6.647509283988646546e-29 3.016153410326994966e-21 1.468115942443034382e-25 3.461594811983056720e-24 1.302896737510991611e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.647177614497136382e-21 0.000000000000000000e+00 6.154731386863136027e-21 1.109188146279967913e-19 1.431950074199516393e+03 1.084552723534479390e-19 1.091515002160414105e-19 1.792795052500346042e-20 6.612020632703694364e-29 3.014618535628357015e-21 1.463416274361227825e-25 3.454062581820196093e-24 1.302743250205659146e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.710705525225204470e-21 0.000000000000000000e+00 6.161581743512974753e-21 1.109342252075982057e-19 1.433550074116701580e+03 1.095999484423803132e-19 1.092671564299467064e-19 1.845073209488089928e-20 6.577745078922216303e-29 3.013130163612370959e-21 1.458858994937627489e-25 3.446758558500040579e-24 1.302621159044654883e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.667492913182142786e-21 0.000000000000000000e+00 6.168224552301335364e-21 1.111321252406972537e-19 1.435150074034071395e+03 1.077069737806991875e-19 1.093828193067683749e-19 1.737992952882641134e-20 6.543469525136783218e-29 3.011641791596212999e-21 1.454301716533765288e-25 3.439454535179041647e-24 1.302509531263149739e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.614461577555483146e-21 0.000000000000000000e+00 6.174867361090462585e-21 1.110713819204245855e-19 1.436800083518928659e+03 1.094455963750813044e-19 1.095021042965014442e-19 1.806357355656001392e-20 6.508549344221776804e-29 3.010109226575855776e-21 1.449601997000141206e-25 3.431922217441751966e-24 1.302394414445815183e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.649110940163244176e-21 0.000000000000000000e+00 6.181717797386841509e-21 1.112995435885583960e-19 1.438450073864227079e+03 1.089877051025354942e-19 1.096213949428570883e-19 1.918639085897057808e-20 6.473642881805686074e-29 3.008612723704538451e-21 1.444902333087634950e-25 3.424389987076831942e-24 1.302279298963819264e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.635740055044382396e-21 0.000000000000000000e+00 6.188568154220447806e-21 1.116042292151578383e-19 1.440050073782158506e+03 1.084419314687918040e-19 1.097370780938914016e-19 1.860112055359978573e-20 6.439918465331103248e-29 3.007161560988274745e-21 1.440345057867106730e-25 3.417085963753269698e-24 1.302167671182337629e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.694974392537900224e-21 0.000000000000000000e+00 6.195210963011906456e-21 1.116216380942878024e-19 1.441650073700272287e+03 1.070085827025642331e-19 1.098527678226112615e-19 1.501215496946876542e-20 6.406638467034336651e-29 3.005695280278816326e-21 1.435787783706174399e-25 3.409781940428874322e-24 1.302040925424059332e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.638526783299617987e-21 0.000000000000000000e+00 6.201853771804122688e-21 1.111921932618414906e-19 1.443300083142795302e+03 1.082053554388388359e-19 1.099720804115149685e-19 1.848008602661862771e-20 6.372318270629858235e-29 3.004160387774143913e-21 1.431088068713136478e-25 3.402249622884841790e-24 1.301887436338341367e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.647622984157797510e-21 0.000000000000000000e+00 6.208745866642518930e-21 1.118313054397359253e-19 1.444950073531954331e+03 1.094648489026628713e-19 1.100913985730770843e-19 1.784808196655669230e-20 6.338533305575525976e-29 3.002625512993530936e-21 1.426388409139136967e-25 3.394717392319696874e-24 1.301733949025066509e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.669255641989958338e-21 0.000000000000000000e+00 6.215700983816019942e-21 1.118472942874403449e-19 1.446550073450622222e+03 1.116755090711056716e-19 1.102071083171866564e-19 1.982670152184029743e-20 6.306394176774457952e-29 3.001137140976165508e-21 1.421831138286780423e-25 3.387413368992772716e-24 1.301614183427535031e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.633059604753907531e-21 0.000000000000000000e+00 6.222445378804647320e-21 1.122924303761473524e-19 1.448200082861480951e+03 1.099294363546971191e-19 1.103264414787223624e-19 1.668718539301955893e-20 6.273250509478077626e-29 2.999602248500948163e-21 1.417131426830887196e-25 3.379881051593287786e-24 1.301499066615533270e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.703951099114080965e-21 0.000000000000000000e+00 6.229400576159312390e-21 1.119017871085773266e-19 1.449850073283441361e+03 1.090467632773041081e-19 1.104457801505834415e-19 1.695229635476069665e-20 6.239918514788921352e-29 2.998078344135131776e-21 1.412431770644671357e-25 3.372348820878403992e-24 1.301378664172443742e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.702246301282935468e-21 0.000000000000000000e+00 6.236355693471079374e-21 1.120595200282505636e-19 1.451500082673094539e+03 1.103670911480481709e-19 1.105651270557617866e-19 1.909811732910719245e-20 6.206478324491949292e-29 2.996615835812484272e-21 1.407732061628495993e-25 3.364816503575722491e-24 1.301228663480007595e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.731798896792977896e-21 0.000000000000000000e+00 6.243310890736357973e-21 1.125230073002631828e-19 1.453150073117019929e+03 1.096088335913064897e-19 1.106844794297452720e-19 1.831777649448397487e-20 6.173038518161728064e-29 2.995153344282641368e-21 1.403032407782878818e-25 3.357284272760569028e-24 1.301078664509945643e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.656910752675456427e-21 0.000000000000000000e+00 6.250266008140713287e-21 1.125078278423529623e-19 1.454800082485562598e+03 1.107922821929895474e-19 1.108038399897915506e-19 1.791717337449805834e-20 6.140781002020344885e-29 2.993674343792164104e-21 1.398332701254210900e-25 3.349751955554257493e-24 1.300945578864438087e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.667169153198084615e-21 0.000000000000000000e+00 6.257221205317005647e-21 1.125615649324769337e-19 1.456450072951352695e+03 1.460757547686520489e-18 1.109232059774878206e-19 1.788362125871163420e-20 6.108642057295391289e-29 2.992177840811563797e-21 1.393633049798182722e-25 3.342219724639291336e-24 1.300830463374310945e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.640366050740533817e-21 0.000000000000000000e+00 6.264176322813525736e-21 1.126729769512314792e-19 1.458100082298879670e+03 1.119226210176763048e-19 1.110425801043802454e-19 1.707790261451007971e-20 6.076554940169356951e-29 2.990681320705667398e-21 1.388933345806116590e-25 3.334687407528916302e-24 1.300715346566876496e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.668950121269322153e-21 0.000000000000000000e+00 6.271131519901232090e-21 1.126670829747421880e-19 1.459750072786434202e+03 1.103903672824106240e-19 1.111619596181285765e-19 1.588513310804754972e-20 6.044846427321569167e-29 2.989181752012332765e-21 1.384233696789995226e-25 3.327155176514595158e-24 1.300602530342547577e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.699481153741807588e-21 0.000000000000000000e+00 6.278112491738786207e-21 1.126119235478808176e-19 1.461400082113040071e+03 9.515411641716164942e-19 1.112813472245904783e-19 1.772827248247592734e-20 6.013137552436360520e-29 2.987681743533600251e-21 1.379533995384971066e-25 3.319622859499725368e-24 1.300490029827660027e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.753650819013815623e-21 0.000000000000000000e+00 6.285178702737337000e-21 1.130068497053364046e-19 1.463050072622259904e+03 1.843080283220847721e-18 1.114007401774714855e-19 1.946452339181648866e-20 5.981572536378029164e-29 2.986189708357542378e-21 1.374834348860440385e-25 3.312090628386501803e-24 1.300369574408396003e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.743998301624881465e-21 0.000000000000000000e+00 6.292244833149906803e-21 1.134094297176314786e-19 1.464700081928037662e+03 1.095618618212350994e-19 1.115201411769632967e-19 2.007146181002119432e-20 5.950294099103284649e-29 2.984727200109239532e-21 1.370134650094299105e-25 3.304558311466712607e-24 1.300219573723835103e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.733878038374467871e-21 0.000000000000000000e+00 6.299311044059260709e-21 1.136322822377990451e-19 1.466350072458824570e+03 1.106282743434560656e-19 1.116395474827910852e-19 1.859760024121048727e-20 5.919016017737062668e-29 2.983264708502405321e-21 1.365435006114457931e-25 3.297026080255035145e-24 1.300069574746126984e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.715829745532200726e-21 0.000000000000000000e+00 6.306377174564192394e-21 1.134982766400448624e-19 1.468000081743866758e+03 5.768661508650619307e-19 1.117589617895028768e-19 1.534644759831914741e-20 5.888050652766306005e-29 2.981802200272481564e-21 1.360735310040483175e-25 3.289493763429904102e-24 1.299940030444769324e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.736306506938191475e-21 0.000000000000000000e+00 6.313443385384745883e-21 1.131302442326862275e-19 1.469700081649314143e+03 5.728412430854049170e-19 1.118820009386076476e-19 1.714090437440757940e-20 5.856415871917110059e-29 2.980295382174471392e-21 1.355893227849757489e-25 3.281733238682193448e-24 1.299824121485118447e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.777302654897935186e-21 0.000000000000000000e+00 6.320723682432591749e-21 1.135109625517522656e-19 1.471350072212592067e+03 1.193057489564046781e-18 1.120014273135711123e-19 1.808021737722548824e-20 5.825711699696113337e-29 2.978832890538838886e-21 1.351193587829970587e-25 3.274201007322193946e-24 1.299711622249692174e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.773847664080561434e-21 0.000000000000000000e+00 6.327789813076667359e-21 1.137743698402791368e-19 1.473000081466392885e+03 8.368528014949124276e-19 1.121208616208437500e-19 2.005315676526476931e-20 5.795233280793453336e-29 2.977370382336606390e-21 1.346493895939909686e-25 3.266668690639680489e-24 1.299565029016062839e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.765044798194497629e-21 0.000000000000000000e+00 6.334856023763428150e-21 1.142217421245657631e-19 1.474700081372480554e+03 3.612371397075291024e-18 1.122439213119941764e-19 2.018967033263432831e-20 5.763894152089923555e-29 2.975863564238028596e-21 1.341651818011206699e-25 3.258908165889046896e-24 1.299410483736570780e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.804306217449159120e-21 0.000000000000000000e+00 6.342136320814016962e-21 1.143685662810069788e-19 1.476350071968027578e+03 1.749407204687743307e-19 1.123633675623942853e-19 1.935517825700860097e-20 5.733494350491326358e-29 2.974399936028419848e-21 1.336952182082071720e-25 3.251375934381738115e-24 1.299271395577005214e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.848952208873959538e-21 0.000000000000000000e+00 6.349205632369087832e-21 1.143438201947812998e-19 1.478000081190795981e+03 2.504608151753271415e-18 1.124828216773697667e-19 1.747412474011893056e-20 5.703650705418647282e-29 2.972933261163736996e-21 1.332252494507118567e-25 3.243843617840888258e-24 1.299161395080724168e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.880801432868438407e-21 0.000000000000000000e+00 6.356348348753474220e-21 1.141598955760737840e-19 1.479700081097517796e+03 1.119283835031458024e-19 1.126059017126964079e-19 1.988964386308799253e-20 5.672902881018810403e-29 2.971422150135539832e-21 1.327410420978175452e-25 3.236083093087360009e-24 1.299048061875793217e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.851627844262068296e-21 0.000000000000000000e+00 6.363707469550886187e-21 1.146744914310867516e-19 1.481400081004453114e+03 1.166179776683489383e-19 1.127289886204137940e-19 1.903078013176445821e-20 5.642475182475501871e-29 2.969913564564234672e-21 1.322568348977585067e-25 3.228322568332856835e-24 1.298910484309027657e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.907434884865962715e-21 0.000000000000000000e+00 6.371066590349221998e-21 1.146524157613767825e-19 1.483050071642896228e+03 6.645034122528246277e-18 1.128484612044936261e-19 1.851277656165891377e-20 5.613688111762239380e-29 2.968451072861978531e-21 1.317868718744516661e-25 3.220790336629726858e-24 1.298760485321858219e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.916627734541743420e-21 0.000000000000000000e+00 6.378209226284018595e-21 1.146858812775984239e-19 1.484700080824406996e+03 1.239024048385485071e-17 1.129679415636822105e-19 1.790465192177937428e-20 5.584900717531627547e-29 2.966988564723821199e-21 1.313169037167521137e-25 3.213258020277218380e-24 1.298610484648994522e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.966962680455445232e-21 0.000000000000000000e+00 6.385351942489805074e-21 1.147094819095195982e-19 1.486400080731967819e+03 1.143443803797936116e-19 1.130910485543447924e-19 1.747765871122226271e-20 5.555377328644173195e-29 2.965513263365627932e-21 1.308326969760716987e-25 3.205497495519860223e-24 1.298494729163680551e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.918712658209201620e-21 0.000000000000000000e+00 6.392711063290848471e-21 1.147632113260564105e-19 1.488100080639739645e+03 1.159918815622405929e-19 1.132141623293317705e-19 1.848632003422376458e-20 5.526007117514636326e-29 2.964039930112225413e-21 1.303484903950159319e-25 3.197736970761538529e-24 1.298381395958804895e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.976012225130058309e-21 0.000000000000000000e+00 6.400070184092805933e-21 1.150451368531723995e-19 1.489800080547722246e+03 1.104683010786225737e-19 1.133372828665345765e-19 1.782485899815879310e-20 5.496636906364630410e-29 2.962556746787245995e-21 1.298642839753710367e-25 3.189976446002254399e-24 1.298255939602230395e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.997004644191775947e-21 0.000000000000000000e+00 6.407429304895675955e-21 1.150632552674392451e-19 1.491450071239396266e+03 1.112630034466364474e-19 1.134567879896830477e-19 1.845916601301140035e-20 5.468522197760767876e-29 2.961094255037807579e-21 1.293943217029693446e-25 3.182444214056124761e-24 1.298105940610384934e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.956823251119670220e-21 0.000000000000000000e+00 6.414571941060903299e-21 1.152794584873066228e-19 1.493100080369698389e+03 1.118821259936807330e-19 1.135763007778345676e-19 1.776584851098421495e-20 5.440577362251511598e-29 2.959631746945040128e-21 1.289534541884402610e-25 3.175269111702820484e-24 1.297955939942339636e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.969065573003079549e-21 0.000000000000000000e+00 6.421714657045012985e-21 1.152890958560097906e-19 1.494800080278295809e+03 1.120116197973836728e-19 1.136994410766907749e-19 1.566966412349082364e-20 5.411785874435674819e-29 2.958171043320550207e-21 1.285510792159771578e-25 3.168513099581498486e-24 1.297828063247031712e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.028338931818432667e-21 0.000000000000000000e+00 6.429176114197329720e-21 1.151093172444124259e-19 1.496500080187101275e+03 1.141759670373224957e-19 1.138225880515464858e-19 1.733279674227570622e-20 5.383249719416261819e-29 2.956735487842003270e-21 1.281487043064053901e-25 3.161757087459349968e-24 1.297714730042212668e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.946030721486737103e-21 0.000000000000000000e+00 6.436658894263757412e-21 1.154656985842932238e-19 1.498200080096113425e+03 1.118521292009673392e-19 1.139457416807563662e-19 1.878844147097941468e-20 5.354747593282185126e-29 2.955299930583368563e-21 1.277463294603199371e-25 3.155001075336379707e-24 1.297601395057489982e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.045566008152147106e-21 0.000000000000000000e+00 6.444141674331095406e-21 1.158189960903567093e-19 1.499900080005331802e+03 1.130026135945525093e-19 1.140689019427674785e-19 1.841593323320073596e-20 5.326296551401333301e-29 2.953826597328712309e-21 1.273439546783232397e-25 3.148245063212590272e-24 1.297450284117756772e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.081483755941640202e-21 0.000000000000000000e+00 6.451624454399340694e-21 1.158823299786270961e-19 1.501600079914755497e+03 1.133950847843076176e-19 1.141920688161186077e-19 1.890570861357154400e-20 5.298228467790421385e-29 2.952353264073878508e-21 1.269415799610253840e-25 3.141489051087984604e-24 1.297299173178043122e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.049528273325190618e-21 0.000000000000000000e+00 6.459107234468489514e-21 1.160813145409785487e-19 1.503300079824384284e+03 1.140835047326767010e-19 1.143152422794400202e-19 1.923587592991899607e-20 5.270160384176125052e-29 2.950879930818866784e-21 1.265392053090441015e-25 3.134733038962563804e-24 1.297161397331138575e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.996564313660002594e-21 0.000000000000000000e+00 6.466590014538541113e-21 1.162547474792078325e-19 1.505000079734217252e+03 1.157025220444697645e-19 1.144384223114527902e-19 1.637366851432001000e-20 5.242296583021168920e-29 2.949406597563678266e-21 1.261368307230051364e-25 3.127977026836331546e-24 1.297048064126377083e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.004399101194219665e-21 0.000000000000000000e+00 6.474072794609491731e-21 1.159378647958627035e-19 1.506700079644253719e+03 1.114757485518390481e-19 1.145616088909683419e-19 1.706651282620308278e-20 5.214807222773769329e-29 2.947933264308313329e-21 1.257344562035421764e-25 3.121221014709290768e-24 1.296934730921623678e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.995208201217242490e-21 0.000000000000000000e+00 6.481555574681337605e-21 1.161592145262710666e-19 1.508400079554492777e+03 1.115039256542724372e-19 1.146848019968880166e-19 1.974495140824334973e-20 5.187317862523094063e-29 2.946459931052773103e-21 1.253320817512971746e-25 3.114465002581444776e-24 1.296794729311186929e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.943381733828039945e-21 0.000000000000000000e+00 6.489038354754075726e-21 1.167020773993590159e-19 1.510100079464934197e+03 1.149200391669273541e-19 1.148080016082026148e-19 1.887252569932979708e-20 5.159913615415099790e-29 2.944986597797057211e-21 1.249297073669200739e-25 3.107708990452794672e-24 1.296643618371548135e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.948751420732637713e-21 0.000000000000000000e+00 6.496521134827703838e-21 1.166794696055313342e-19 1.511800079375576843e+03 1.160003590670515940e-19 1.149312077039919392e-19 1.751661075568274815e-20 5.132568936001358512e-29 2.943517325733219325e-21 1.245273330510695873e-25 3.100952978323344866e-24 1.296494876458062480e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.046716482668521533e-21 0.000000000000000000e+00 6.504087642613339911e-21 1.165938757518012222e-19 1.513550088918984784e+03 1.157330030939352047e-19 1.150580449582257453e-19 1.998124257646782224e-20 5.104419846324414146e-29 2.942071665675621172e-21 1.241131219882419666e-25 3.093998221662535495e-24 1.296380745524434411e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.027984137596861584e-21 0.000000000000000000e+00 6.511924142460917231e-21 1.171137308061928546e-19 1.515300079192237035e+03 1.137754793856712748e-19 1.151848876425657296e-19 1.864406744307934285e-20 5.077273779119678413e-29 2.940626021536847378e-21 1.236989155605925838e-25 3.087043541583733549e-24 1.296266615847575876e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.025664618128157968e-21 0.000000000000000000e+00 6.519760556017209412e-21 1.170181685581231699e-19 1.517000079103491998e+03 1.145849370965573382e-19 1.153081134442782778e-19 1.885664764434404043e-20 5.051065447154497720e-29 2.939193264776973459e-21 1.232965414585303568e-25 3.080287529451850101e-24 1.296139174505348338e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.057783261326718925e-21 0.000000000000000000e+00 6.527373113957600806e-21 1.171752567782961516e-19 1.518700079014945004e+03 1.134510223622444574e-19 1.154313456464579567e-19 1.945544843572148938e-20 5.024873795022087794e-29 2.937719931520380742e-21 1.228941674277566964e-25 3.073531517319179807e-24 1.295988063565785152e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.971050118655748638e-21 0.000000000000000000e+00 6.534985671898878429e-21 1.173909587724703474e-19 1.520400078926596279e+03 1.142812538570575124e-19 1.155545842286275325e-19 1.940651110168351623e-20 4.998948796369406847e-29 2.936246598263616497e-21 1.224917934689744656e-25 3.066775505185721565e-24 1.295836952626242466e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.979124574405763316e-21 0.000000000000000000e+00 6.542598229841044538e-21 1.175047770493992909e-19 1.522150088416601420e+03 1.134858737981321318e-19 1.156814548122851881e-19 1.795127177231312063e-20 4.972261151646829294e-29 2.934784709568894460e-21 1.220775827902713991e-25 3.059820748737141454e-24 1.295713354975758708e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.969358121452344172e-21 0.000000000000000000e+00 6.550434729449485306e-21 1.173982184906629407e-19 1.523900078745322617e+03 1.151563782688133068e-19 1.158083307237999084e-19 1.803399829507097049e-20 4.945698818820162471e-29 2.933339065384298957e-21 1.216633767247429234e-25 3.052866068437899053e-24 1.295599225295409990e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.022545942288993821e-21 0.000000000000000000e+00 6.558271143254166777e-21 1.175385660642087950e-19 1.525600078657575295e+03 1.138244252277830621e-19 1.159315886950183711e-19 1.872617853330097613e-20 4.920198820136371554e-29 2.931930368094664464e-21 1.212610029906328590e-25 3.046110056302050883e-24 1.295484006324782183e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.067390068525737077e-21 0.000000000000000000e+00 6.565883701199025426e-21 1.177703986343076326e-19 1.527300078570023516e+03 1.141511126525480587e-19 1.160548529639939759e-19 1.759139688054786520e-20 4.894698821449648000e-29 2.930489063821067144e-21 1.208586293314650824e-25 3.039354044165425418e-24 1.295336180405719315e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.004643320364162222e-21 0.000000000000000000e+00 6.573496259144760524e-21 1.177145238267648507e-19 1.529050088017611870e+03 1.146285014838833557e-19 1.161817499014287224e-19 1.843637066964731511e-20 4.868661201740225282e-29 2.929005360158981004e-21 1.204444189745470053e-25 3.032399287885414871e-24 1.295184005836180132e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.066334093796969686e-21 0.000000000000000000e+00 6.581378301570206325e-21 1.179717662762742580e-19 1.530800078390382168e+03 1.138526955000579115e-19 1.163086520863020048e-19 1.875247957032662491e-20 4.842848843741863277e-29 2.927539065677510139e-21 1.200302132135456547e-25 3.025444607411116014e-24 1.295031832925357894e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.138331384375048568e-21 0.000000000000000000e+00 6.589310044360887054e-21 1.181500194584893484e-19 1.532500078303423834e+03 1.147111143357927739e-19 1.164319354949266335e-19 1.821196378471746568e-20 4.817773845024498347e-29 2.926134717923258465e-21 1.196278397883219398e-25 3.018688595272131846e-24 1.294884007006355399e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.174684588684551388e-21 0.000000000000000000e+00 6.597015207923061423e-21 1.181888666344778170e-19 1.534250087719295834e+03 1.165010617937753586e-19 1.165588520692012079e-19 1.819779576001330701e-20 4.792169554093602242e-29 2.924689057971016579e-21 1.192136296823489707e-25 3.011733839118166252e-24 1.294731832439689313e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.157207269848306313e-21 0.000000000000000000e+00 6.604947037025636246e-21 1.183113605030712336e-19 1.536000078124998026e+03 1.146326055957810069e-19 1.166857738312410882e-19 1.886357980211926908e-20 4.766648860677111634e-29 2.923212977241849495e-21 1.187994241595261477e-25 3.004779158512991895e-24 1.294610095974054652e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.100792202954989851e-21 0.000000000000000000e+00 6.612878779965578802e-21 1.185384912290368009e-19 1.537700078038627225e+03 1.165526020807654962e-19 1.168090761943473136e-19 1.919554388483961242e-20 4.741857195270018947e-29 2.921771672967250842e-21 1.183970509755735667e-25 2.998023146371672901e-24 1.294499226534839503e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.159420938989108945e-21 0.000000000000000000e+00 6.620583943530416371e-21 1.187160201049094452e-19 1.539450087422995011e+03 1.172755519102691046e-19 1.169360122156699385e-19 1.839248971299206415e-20 4.716748746937070693e-29 2.920293406041873841e-21 1.179828411281402945e-25 2.991068390342909211e-24 1.294379658934760180e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.136533762797113010e-21 0.000000000000000000e+00 6.628515772490200040e-21 1.187132653599738799e-19 1.541200077861404679e+03 1.177775979798085173e-19 1.170629533658715500e-19 1.617798079494004193e-20 4.691665550653198566e-29 2.918847761766665591e-21 1.175686358513008683e-25 2.984113709607750892e-24 1.294227486018435312e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.238398432336689480e-21 0.000000000000000000e+00 6.636447515578388044e-21 1.185206314236694143e-19 1.542950087224686058e+03 1.164573529961241413e-19 1.171899023709005839e-19 1.741214537922708039e-20 4.666741646677825016e-29 2.917402101857868095e-21 1.171544261823227684e-25 2.977158953662787092e-24 1.294075311456509948e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.161691795261566229e-21 0.000000000000000000e+00 6.644379344442598192e-21 1.188176448945337181e-19 1.544700077684985672e+03 1.153681256726956363e-19 1.173168564656104893e-19 1.818988904564572864e-20 4.642456064779790072e-29 2.915956457564576792e-21 1.167402210756076117e-25 2.970204272840635579e-24 1.293942705423291082e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.216869698820675355e-21 0.000000000000000000e+00 6.652311087630000928e-21 1.190620130240947446e-19 1.546450087027275231e+03 1.141671966656782693e-19 1.174438183701815419e-19 1.772846510859599698e-20 4.618170220845976257e-29 2.914510797673120564e-21 1.163260115887747721e-25 2.963249516979095878e-24 1.293828574503267150e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.183773694183788046e-21 0.000000000000000000e+00 6.660286596343589147e-21 1.191165322283064728e-19 1.548200077509363837e+03 1.181599084244889473e-19 1.175707853255822591e-19 1.941023940740026544e-20 4.593857254661352978e-29 2.913065153361830092e-21 1.159118066559732699e-25 2.956294836070352309e-24 1.293714444813276933e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.175163397691568409e-21 0.000000000000000000e+00 6.668364677139517904e-21 1.195033723958969990e-19 1.549950086830755708e+03 1.147337161283220950e-19 1.176977600462481562e-19 2.039848319615589706e-20 4.569502958271982292e-29 2.911646738307048866e-21 1.154975973550826293e-25 2.949340080291862386e-24 1.293569484264109468e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.252751208067031571e-21 0.000000000000000000e+00 6.676442844899013759e-21 1.197964028607469450e-19 1.551700077334534399e+03 1.154695964832386553e-19 1.178247397792361208e-19 1.854849356362145907e-20 4.545148923761062215e-29 2.910231852367823343e-21 1.150833926000921193e-25 2.942385399296919816e-24 1.293420549064047647e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.289990493926643859e-21 0.000000000000000000e+00 6.684520925795065295e-21 1.196224273778951172e-19 1.553450086635121579e+03 1.156052081096707666e-19 1.179517272332596825e-19 1.830522842782524728e-20 4.521309037159586459e-29 2.908810797997073657e-21 1.146691834890514846e-25 2.935430643601110492e-24 1.293270964556147564e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.306608254115658277e-21 0.000000000000000000e+00 6.692599093458524954e-21 1.197112194306313596e-19 1.555200077160491901e+03 1.143665863031446333e-19 1.180787196614373764e-19 1.979959347738992873e-20 4.497737736205619454e-29 2.907365153650028596e-21 1.142549789158818032e-25 2.928475962520359773e-24 1.293118791632544412e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.276259513390870284e-21 0.000000000000000000e+00 6.700677174454244869e-21 1.200727732033289762e-19 1.556950086440367386e+03 1.163211309877768155e-19 1.182057197667838333e-19 1.867762862437870399e-20 4.474166182639949908e-29 2.905919493810131244e-21 1.138407699987135462e-25 2.921521206906861503e-24 1.292966617078155564e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.279044907069582791e-21 0.000000000000000000e+00 6.708755342022097905e-21 1.200184896143475029e-19 1.558750086340548478e+03 1.165178085395584063e-19 1.183363543146708260e-19 1.807627113057839251e-20 4.450174361346171325e-29 2.904450994022535098e-21 1.134147289240901924e-25 2.914367782319894701e-24 1.292834380559645092e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.284390427034705265e-21 0.000000000000000000e+00 6.717064269856363983e-21 1.200558009005930937e-19 1.560500076898428006e+03 1.193034171126358847e-19 1.184633658116914035e-19 1.853102216771230925e-20 4.426888772698467624e-29 2.903036108039568772e-21 1.130005246341438902e-25 2.907413101109948336e-24 1.292722679156280071e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.431753752738807056e-21 0.000000000000000000e+00 6.725142351002149200e-21 1.202572162887620992e-19 1.562250086147114644e+03 1.185140568791800835e-19 1.185903849201360196e-19 1.755334183264021563e-20 4.403639691139726185e-29 2.901621206944886048e-21 1.125863160184778808e-25 2.900458345620398598e-24 1.292610976559907149e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.254375674669334007e-21 0.000000000000000000e+00 6.733220518426031449e-21 1.202282586768622515e-19 1.564050086047971490e+03 1.160913125677682090e-19 1.187210389526418153e-19 1.895816942859897552e-20 4.380129488353024786e-29 2.900165887876108312e-21 1.121992875725719987e-25 2.893806295935564220e-24 1.292460974898791058e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.298687626925209302e-21 0.000000000000000000e+00 6.741547146396715514e-21 1.205723983858184530e-19 1.565800076638138535e+03 1.175784726348481507e-19 1.188480693335723071e-19 1.828666405581102068e-20 4.357272468399822815e-29 2.898751001867036608e-21 1.118551291144216606e-25 2.887751819870911342e-24 1.292312039691655018e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.298788832363555161e-21 0.000000000000000000e+00 6.749777568271560101e-21 1.205942584165979294e-19 1.567550085855845055e+03 1.172231702746048115e-19 1.189751072609922317e-19 1.926813586024913831e-20 4.334505015083794548e-29 2.897336100797401506e-21 1.115109670334090978e-25 2.881697279360202390e-24 1.292163102899235259e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.356136849181331130e-21 0.000000000000000000e+00 6.758008077754023824e-21 1.208749781083821358e-19 1.569350085757370834e+03 1.170120720465644958e-19 1.191057805895150608e-19 2.081405790019698733e-20 4.311288689823299395e-29 2.895880781728082855e-21 1.111569736766577388e-25 2.875469785120290437e-24 1.292009911585208083e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.277224927360622878e-21 0.000000000000000000e+00 6.766473699596494272e-21 1.212563469215778235e-19 1.571150085659122169e+03 1.179690666711287367e-19 1.192364604289232545e-19 2.028736189091671037e-20 4.288072364559895146e-29 2.894425462658582143e-21 1.108029803635068198e-25 2.869242290879598249e-24 1.291856720271200844e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.341234283122256562e-21 0.000000000000000000e+00 6.774939321440025485e-21 1.212987458112284861e-19 1.572950085561098149e+03 1.184540583074420197e-19 1.193671467578330201e-19 2.050434704511707530e-20 4.265378939042384517e-29 2.892970143588899370e-21 1.104489870943761439e-25 2.863014796638129133e-24 1.291703528957214482e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.339375303522662847e-21 0.000000000000000000e+00 6.783404943284613704e-21 1.214640081117717687e-19 1.574700076204989728e+03 1.204693931706466031e-19 1.194942084398932533e-19 1.944132097515870825e-20 4.243679055058128788e-29 2.891555257536391175e-21 1.101048288355165007e-25 2.856960320387604518e-24 1.291554593745696387e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.370696903013173261e-21 0.000000000000000000e+00 6.791635365412131272e-21 1.214159409688320541e-19 1.576450085371137675e+03 1.180286103534590680e-19 1.196212775611903604e-19 1.985410933900656105e-20 4.221978941397893988e-29 2.890140356508441924e-21 1.097606669764639266e-25 2.850905780055273527e-24 1.291405656957855226e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.392120323927783487e-21 0.000000000000000000e+00 6.799865874652108378e-21 1.216090847285201536e-19 1.578250085273771447e+03 1.176887371925359081e-19 1.197519828747819172e-19 1.936394509871060918e-20 4.199537710458202694e-29 2.888685037438227264e-21 1.094066738394381527e-25 2.844678285811528360e-24 1.291289701460185893e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.402614118549586689e-21 0.000000000000000000e+00 6.808331496499789369e-21 1.216595796793285871e-19 1.580050085176627135e+03 1.193744327465466787e-19 1.198826945944249588e-19 1.791089472378726302e-20 4.177056079018453363e-29 2.887229718367833176e-21 1.090526807481419100e-25 2.838450791567015449e-24 1.291174807974746385e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.424304559967269762e-21 0.000000000000000000e+00 6.816797118348514575e-21 1.215670829288867656e-19 1.581850085079704058e+03 1.180182645762817769e-19 1.200134126991881415e-19 1.979766840721089373e-20 4.154594972237174532e-29 2.885785349311900983e-21 1.086986877030225752e-25 2.832223297321737364e-24 1.291047235538834353e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.440534438510222742e-21 0.000000000000000000e+00 6.825262740198280987e-21 1.219891187630966051e-19 1.583650084983001079e+03 1.183837652756199974e-19 1.201441371682302551e-19 1.907424285774290513e-20 4.132850973405346812e-29 2.884360349388457455e-21 1.083446947045333565e-25 2.825995803075697412e-24 1.290897235710650805e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.486272679234883622e-21 0.000000000000000000e+00 6.833835615103253940e-21 1.220050281419423256e-19 1.585450084886517743e+03 1.169099437840592226e-19 1.202748679807996453e-19 2.111196753047979672e-20 4.111106974570865033e-29 2.882935349464840141e-21 1.079907017531333853e-25 2.819768308828897796e-24 1.290747235882486816e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.538152504790981469e-21 0.000000000000000000e+00 6.842416383737359347e-21 1.224713280264424454e-19 1.587250084790253595e+03 1.182728710805809971e-19 1.204056051162338282e-19 1.752795215835663778e-20 4.089434989300176890e-29 2.881515890697034589e-21 1.076367088492877625e-25 2.813540814581339620e-24 1.290595019594369688e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.498628364093995265e-21 0.000000000000000000e+00 6.850997152372510474e-21 1.220322854960966799e-19 1.589050084694207044e+03 1.190888703265852172e-19 1.205363485539588404e-19 1.842744677535662084e-20 4.067978990445051661e-29 2.880098869496049985e-21 1.072827159934679257e-25 2.807313320333028760e-24 1.290441828280541688e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.472788208246648210e-21 0.000000000000000000e+00 6.859577921008698292e-21 1.222928761412926067e-19 1.590850084598378317e+03 1.177844125942199532e-19 1.206670982734890949e-19 1.791093892698748926e-20 4.046522991587329545e-29 2.878681183026283949e-21 1.069287231861512818e-25 2.801085826083964114e-24 1.290292029832937016e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.507781650805644338e-21 0.000000000000000000e+00 6.868158689645925812e-21 1.223470852461248371e-19 1.592650084502765822e+03 1.197919666833776728e-19 1.207978542544265138e-19 2.110752793454722738e-20 4.025223408275539717e-29 2.877256183101977138e-21 1.065747304278218266e-25 2.794858331834151560e-24 1.290179529961871107e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.587211989771594920e-21 0.000000000000000000e+00 6.876739458284182501e-21 1.229882066930096371e-19 1.594450084407369332e+03 1.195733620601934269e-19 1.209286164764603844e-19 2.041199488745600277e-20 4.004098609395113054e-29 2.875831183177499174e-21 1.062207377189698471e-25 2.788630837583591832e-24 1.290067030090813285e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.571188824923221287e-21 0.000000000000000000e+00 6.885320226923469863e-21 1.229990255387034099e-19 1.596250084312187937e+03 1.190636571440787249e-19 1.210593849193668293e-19 1.770273111183013969e-20 3.982973810512161811e-29 2.874406183252851187e-21 1.058667450600922650e-25 2.782403343332287502e-24 1.289938903480346861e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.571161468507676844e-21 0.000000000000000000e+00 6.893900995563781880e-21 1.227079917444336925e-19 1.598050084217220956e+03 1.212159068243382511e-19 1.211901595630081084e-19 1.955041543183054357e-20 3.962059025775187788e-29 2.872981183328033177e-21 1.055127524516926373e-25 2.776175849080241875e-24 1.289788903652299858e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.623816258394806342e-21 0.000000000000000000e+00 6.902481764205117047e-21 1.231197086834269469e-19 1.599850084122467706e+03 1.220536720731710134e-19 1.213209403873325465e-19 1.832090865239811624e-20 3.941236626871292821e-29 2.871556183403046271e-21 1.051587598942812250e-25 2.769948354827456423e-24 1.289638903824273355e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.607356079342442083e-21 0.000000000000000000e+00 6.911062532847470850e-21 1.230590935646368569e-19 1.601650084027927278e+03 1.203175227035824104e-19 1.214517273723738352e-19 1.780077392416677321e-20 3.920414227964936613e-29 2.870159310228472806e-21 1.048047673883753605e-25 2.763720860573934816e-24 1.289488903996267353e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.677885085769902004e-21 0.000000000000000000e+00 6.919772641989440357e-21 1.231154412340121801e-19 1.603450083933599444e+03 1.181279861319429859e-19 1.215825204982505998e-19 1.967850118704901341e-20 3.899882243828434227e-29 2.868771810301183862e-21 1.044507749344991718e-25 2.757493366319677791e-24 1.289338904168281664e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.593300975772821639e-21 0.000000000000000000e+00 6.928527181381804285e-21 1.235262500787140566e-19 1.605250083839482841e+03 1.209744787171010700e-19 1.217133197451659897e-19 1.820608427151750402e-20 3.879376644900610934e-29 2.867381183627076328e-21 1.040967825331841569e-25 2.751265872064689756e-24 1.289188904340316663e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.635938909304936127e-21 0.000000000000000000e+00 6.937281720775195878e-21 1.234316299957876184e-19 1.607100093335819793e+03 1.211361340828768488e-19 1.218477593593337941e-19 2.015373490402543137e-20 3.858417796469370666e-29 2.865916592775809372e-21 1.037329551783956315e-25 2.744865358668853014e-24 1.289034737051081989e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.528547452875169357e-21 0.000000000000000000e+00 6.946279488475566580e-21 1.238617787017354264e-19 1.608950083646682742e+03 1.201760861497967551e-19 1.219822040029369257e-19 1.848279964305119317e-20 3.838060648185914433e-29 2.864452017113042857e-21 1.033691316533959291e-25 2.738464911649369254e-24 1.288880571360675737e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.603163536830168102e-21 0.000000000000000000e+00 6.955277162864828584e-21 1.237372603708659659e-19 1.610750083553208242e+03 1.212060674527157200e-19 1.221130218312406690e-19 1.963587226677962059e-20 3.818253590390971709e-29 2.863058100174108018e-21 1.030151394160529286e-25 2.732237417392159901e-24 1.288732017251518641e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.632804265617154357e-21 0.000000000000000000e+00 6.964031702261343794e-21 1.240453213194765991e-19 1.612550083459942243e+03 1.197245038402007238e-19 1.222438457011533534e-19 1.846934722341088536e-20 3.798548506469803945e-29 2.861698916571063941e-21 1.026611472335016483e-25 2.726009923134229089e-24 1.288585078644614213e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.570830446609993162e-21 0.000000000000000000e+00 6.972786241658871622e-21 1.239926541297456240e-19 1.614350083366884519e+03 1.185228174739642068e-19 1.223746755932986791e-19 2.007265825305704905e-20 3.779023801596853033e-29 2.860339732967862629e-21 1.023071551063113535e-25 2.719782428875577552e-24 1.288438140037729534e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.626440035922297068e-21 0.000000000000000000e+00 6.981540781057412068e-21 1.243732816914504761e-19 1.616200092810293199e+03 1.210723913629620886e-19 1.225091465976682941e-19 1.920511258759320841e-20 3.758956640340114011e-29 2.858920761792065788e-21 1.019433280468442369e-25 2.713381915662857851e-24 1.288313906484843833e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.588809021079300311e-21 0.000000000000000000e+00 6.990538548500361169e-21 1.243674513410963041e-19 1.618050083176249245e+03 1.200864479506270652e-19 1.226436225355226843e-19 2.104201302777803892e-20 3.738829893046178346e-29 2.857494727551641005e-21 1.015795047989595446e-25 2.706981468452767314e-24 1.288198282213733748e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.563613581425287683e-21 0.000000000000000000e+00 6.999536223157575699e-21 1.247958192512474164e-19 1.619850083083822710e+03 1.209999569703752539e-19 1.227744707097323760e-19 1.970913392377804678e-20 3.719202694053997257e-29 2.856106058016627178e-21 1.012255128445387030e-25 2.700753974191932296e-24 1.288080997595236872e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.635260641290026001e-21 0.000000000000000000e+00 7.008389624163640746e-21 1.247105080074451176e-19 1.621700092495526633e+03 1.205478960774136953e-19 1.229089604408381829e-19 2.059616843412724878e-20 3.699030191428777652e-29 2.854671356840203806e-21 1.008616859708940662e-25 2.694353461088902014e-24 1.287929976584404031e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.647055137265215203e-21 0.000000000000000000e+00 7.017572060483899378e-21 1.249870320457755802e-19 1.623550082894478237e+03 1.198279497829958149e-19 1.230434550484625981e-19 1.921671360081384719e-20 3.679432460178162473e-29 2.853236670408363802e-21 1.004978628980494712e-25 2.687953013764656281e-24 1.287778957125669668e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.590464997341968626e-21 0.000000000000000000e+00 7.026754402435239813e-21 1.248975653468567930e-19 1.625400092284973198e+03 1.190169115622027032e-19 1.231779572750226602e-19 1.974456947746033442e-20 3.659945694598281945e-29 2.851806178863666322e-21 1.001340361526713916e-25 2.681552500735003295e-24 1.287626405349133951e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.606788389219861260e-21 0.000000000000000000e+00 7.035936838650228319e-21 1.251135022808443529e-19 1.627250082705994828e+03 1.201306928853084051e-19 1.233124643402056977e-19 1.722298050952756018e-20 3.640511465363559725e-29 2.850380144580795848e-21 9.977021320093584435e-26 2.675152053334401491e-24 1.287472239649916945e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.631962861411880627e-21 0.000000000000000000e+00 7.045119180711112038e-21 1.248748569093542381e-19 1.629050082614609664e+03 1.236173841823739207e-19 1.234433426989450195e-19 1.864873719226255551e-20 3.622179158601974486e-29 2.848992644651238294e-21 9.941622154820522604e-26 2.668924559069963583e-24 1.287322239822200961e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.570382146666152359e-21 0.000000000000000000e+00 7.054053397171180946e-21 1.252062180840742495e-19 1.630900091973754570e+03 1.212322692554986006e-19 1.235778633491540430e-19 1.934777820684110236e-20 3.603337524821145249e-29 2.847591767285124041e-21 9.905239499852829030e-26 2.662524046148772725e-24 1.287170793786753989e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.563216847245848740e-21 0.000000000000000000e+00 7.063235833230564844e-21 1.254449246013283248e-19 1.632750082427395455e+03 1.205549764842308527e-19 1.237123887822803238e-19 1.897375857130158602e-20 3.584473273978422572e-29 2.846194835718089127e-21 9.868857223200030393e-26 2.656123598635317219e-24 1.287019774323750795e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.706108221015017882e-21 0.000000000000000000e+00 7.072418175453353068e-21 1.255272666571914203e-19 1.634600091765567186e+03 1.232962467445093517e-19 1.238469217262292834e-19 1.880906463483073016e-20 3.565537884281842019e-29 2.844797889891306405e-21 9.832474581748181196e-26 2.649723085786687791e-24 1.286868753319193777e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.627129060149592382e-21 0.000000000000000000e+00 7.081600611408637443e-21 1.256320162038020846e-19 1.636450082241027985e+03 1.227056625368363369e-19 1.239814594160366360e-19 1.897881751120866882e-20 3.546602687650655096e-29 2.843400958307795011e-21 9.796092317915243593e-26 2.643322638197741669e-24 1.286717733854487339e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.680290336746967891e-21 0.000000000000000000e+00 7.090782953739727629e-21 1.257930175836241004e-19 1.638300091558320219e+03 1.206291795962489838e-19 1.241160045738200465e-19 2.103809267797245808e-20 3.527808489000459731e-29 2.842004012496778583e-21 9.764018107209893302e-26 2.637507468712066759e-24 1.286566712851712934e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.687223587693068361e-21 0.000000000000000000e+00 7.100016224590408636e-21 1.262532016429721148e-19 1.640150082055501116e+03 1.214746916255648155e-19 1.242505544407361715e-19 1.880547692414222638e-20 3.509163486734753649e-29 2.840622939278929320e-21 9.733733773529153992e-26 2.631935487006432554e-24 1.286417407803108907e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.696665376421526484e-21 0.000000000000000000e+00 7.109337682258703863e-21 1.260339832554414820e-19 1.642000091352007303e+03 1.227403946024351707e-19 1.243851117331207213e-19 1.877875386667306989e-20 3.490518295001338086e-29 2.839253932399514743e-21 9.703449135049851357e-26 2.626363448679158138e-24 1.286269407222128379e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.708975351852853978e-21 0.000000000000000000e+00 7.118659234650252286e-21 1.261637078771108060e-19 1.643900091246423926e+03 1.242195439456478166e-19 1.245233112923287268e-19 1.979005960066821200e-20 3.471834495313699013e-29 2.837847932477646254e-21 9.672346153948936846e-26 2.620640843796306721e-24 1.286117407397751604e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.759966200724134690e-21 0.000000000000000000e+00 7.128232672250369682e-21 1.264570990953770694e-19 1.645750081776290472e+03 1.242638524032579993e-19 1.246578794395857753e-19 1.888129235325915170e-20 3.453804202995692492e-29 2.836454019883209138e-21 9.642061828736776819e-26 2.615068861992226701e-24 1.285966714310077079e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.685101175031944650e-21 0.000000000000000000e+00 7.137554130083357498e-21 1.264478325250333184e-19 1.647600091041512542e+03 1.225740436612996791e-19 1.247924549486512954e-19 1.947658026788490488e-20 3.435773728080028304e-29 2.835057074111511022e-21 9.611777199858167026e-26 2.609496823759176973e-24 1.285815693311747171e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.808727885107186809e-21 0.000000000000000000e+00 7.146875682317274574e-21 1.266767698519882352e-19 1.649450081592852257e+03 1.246620686729847663e-19 1.249270350759630903e-19 1.866198502128299497e-20 3.417999216708618843e-29 2.833660142470703211e-21 9.581492880385409825e-26 2.603924841890421989e-24 1.285664673841118498e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.782450063574105028e-21 0.000000000000000000e+00 7.156197140258459028e-21 1.266860854012770568e-19 1.651300090837519747e+03 1.242299157669578026e-19 1.250616225234560903e-19 1.816021751437928526e-20 3.400239127959811190e-29 2.832263196714525758e-21 9.551208257992104532e-26 2.598352803719280406e-24 1.285513652844544686e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.757968942709438482e-21 0.000000000000000000e+00 7.165518692388809221e-21 1.267453196760055560e-19 1.653200090733121215e+03 1.225715302407899198e-19 1.251998529551284873e-19 1.973419827291495056e-20 3.382040679986623488e-29 2.830828502915806610e-21 9.520105292671347611e-26 2.592630198832860262e-24 1.285358550983039912e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.728382326805331681e-21 0.000000000000000000e+00 7.175092129994896999e-21 1.271157103428399319e-19 1.655100090628962789e+03 1.248230882060961053e-19 1.253380896326203421e-19 1.875324106850885534e-20 3.364063757895198719e-29 2.829411932934567529e-21 9.489002330668277706e-26 2.586907593945717188e-24 1.285229410237178525e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.745713165900856260e-21 0.000000000000000000e+00 7.184665567602194501e-21 1.271047237346265588e-19 1.656950081223531470e+03 1.233164053164464897e-19 1.254726938075987145e-19 2.189037520329763822e-20 3.346560000731201813e-29 2.828042939894586863e-21 9.458718023194650005e-26 2.581335611946760776e-24 1.285118410923780544e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.760947137820150371e-21 0.000000000000000000e+00 7.194025575688343169e-21 1.277387071198750228e-19 1.658800090426812403e+03 1.230324765491982166e-19 1.256073052194211847e-19 1.887801685621733307e-20 3.329147617786742053e-29 2.826673933084158570e-21 9.428433414307611795e-26 2.575763573900271553e-24 1.285007410493882042e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.774798634211779364e-21 0.000000000000000000e+00 7.203554372899065996e-21 1.273909552361937195e-19 1.660700090323355198e+03 1.247909381051238150e-19 1.257455601858994144e-19 2.007214308344103473e-20 3.311419157213616237e-29 2.825267933160716987e-21 9.397330462275353593e-26 2.570040969011016263e-24 1.284857408858925308e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.875351970035686000e-21 0.000000000000000000e+00 7.213340655952384168e-21 1.277146110775411095e-19 1.662600090220134916e+03 1.250884615503111195e-19 1.258838213172331015e-19 2.093403392445106943e-20 3.293690696638279172e-29 2.823861933237100115e-21 9.366227513692730499e-26 2.564318364121047227e-24 1.284705409034726832e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.841570273809848377e-21 0.000000000000000000e+00 7.223126939006921091e-21 1.279878604501633843e-19 1.664500090117149966e+03 1.239022090510862747e-19 1.260220885931314668e-19 1.947425222393338046e-20 3.276137633847099236e-29 2.822455933313309082e-21 9.335124568594287585e-26 2.558595759230369589e-24 1.284553409210549609e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.830343314147005299e-21 0.000000000000000000e+00 7.232913222062672254e-21 1.278934618790456333e-19 1.666350080765343591e+03 1.262115538347647426e-19 1.261567224680922990e-19 1.896912596412630320e-20 3.259146181278305510e-29 2.821086940233645983e-21 9.304840276883222942e-26 2.553023777069900621e-24 1.284405410121905051e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.729783178403965405e-21 0.000000000000000000e+00 7.242441923702159444e-21 1.279462308133083193e-19 1.668200089917273772e+03 1.245889177549115258e-19 1.262913634773819522e-19 2.138726855612112310e-20 3.242154558759808703e-29 2.819717933461217567e-21 9.274555685639309161e-26 2.547451739178074495e-24 1.284257409553000706e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.871557652090191796e-21 0.000000000000000000e+00 7.251970720648390400e-21 1.284662996535636298e-19 1.670100089814978901e+03 1.248705022060093286e-19 1.264296487463841490e-19 1.951877121023270252e-20 3.224900724599652930e-29 2.818311933536915711e-21 9.243452751015358911e-26 2.541729134285318436e-24 1.284105409728885172e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.854657577860439463e-21 0.000000000000000000e+00 7.261757003707695505e-21 1.283044833867987970e-19 1.672000089712916406e+03 1.275212999463018348e-19 1.265679400807112845e-19 2.155676901228925278e-20 3.207683802447572866e-29 2.816905933612441950e-21 9.212349820016481711e-26 2.536006529391862223e-24 1.283953409904790516e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.808178825142909548e-21 0.000000000000000000e+00 7.271543286768196794e-21 1.287646361832213090e-19 1.673900089611085605e+03 1.224740837177175851e-19 1.267062374605037468e-19 1.912374914023797531e-20 3.190528272084081002e-29 2.815499935480018167e-21 9.181246892679563287e-26 2.530283924497708428e-24 1.283801410080717301e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.794095288944945550e-21 0.000000000000000000e+00 7.281329569829891256e-21 1.285159635432740674e-19 1.675800089509485815e+03 1.236816231816103051e-19 1.268445408659876039e-19 2.071288760059593068e-20 3.173894310709407229e-29 2.814131935553170226e-21 9.150143969042005942e-26 2.524561319602858887e-24 1.283649410256665150e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.799204052328556840e-21 0.000000000000000000e+00 7.291115852892775882e-21 1.288988731487591491e-19 1.677700089408115900e+03 1.259759524127774418e-19 1.269828502774741704e-19 2.043426102948537144e-20 3.157260349332721191e-29 2.812763935626156775e-21 9.119041049141712479e-26 2.518838714707316906e-24 1.283497410432634440e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.754642427115394764e-21 0.000000000000000000e+00 7.301120071227217093e-21 1.289890869999629358e-19 1.679600089306975633e+03 1.269369560608639335e-19 1.271211656753596942e-19 1.861081359150562354e-20 3.140703380544353485e-29 2.811381933912838027e-21 9.087938133017099984e-26 2.513116109811083588e-24 1.283345410608624984e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.822050520703107170e-21 0.000000000000000000e+00 7.311125185043837264e-21 1.288528339582885939e-19 1.681500089206063649e+03 1.271324624768844296e-19 1.272594870401246587e-19 2.022421100913668295e-20 3.124313192735616790e-29 2.809975933987513020e-21 9.056835220707127369e-26 2.507393504914162238e-24 1.283193410784637156e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.801757203505583465e-21 0.000000000000000000e+00 7.321130298861658132e-21 1.292315659757064420e-19 1.683400089105379948e+03 1.255373427822678163e-19 1.273978143523336381e-19 2.101863551082779547e-20 3.107923004924910991e-29 2.808569934062019119e-21 9.025732312251273567e-26 2.501670900016553591e-24 1.283041410960670770e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.804731733810839520e-21 0.000000000000000000e+00 7.331135412680682706e-21 1.294950225453956718e-19 1.685300089004922711e+03 1.257114485416076906e-19 1.275361475926345513e-19 2.055713591532734888e-20 3.091653582576996877e-29 2.807211701878878180e-21 8.994629407689583445e-26 2.495948295118262791e-24 1.282891607352344971e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.740474152669580751e-21 0.000000000000000000e+00 7.341140526500898949e-21 1.295547622520763736e-19 1.687200088904691938e+03 1.251785100167784839e-19 1.276744867417584211e-19 2.038460522735554016e-20 3.075492828712544345e-29 2.805870525479041078e-21 8.963526507062634518e-26 2.490225690219289836e-24 1.282742587917125521e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.782260590032240392e-21 0.000000000000000000e+00 7.351145640322306861e-21 1.296661055132169764e-19 1.689100088804686720e+03 1.288792918345769193e-19 1.278128317805189166e-19 1.963930717344980089e-20 3.059332074846173156e-29 2.804527386553462514e-21 8.932423610411586306e-26 2.484503085319637666e-24 1.282593568481926571e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.865839519079060213e-21 0.000000000000000000e+00 7.361150754144903433e-21 1.296916627775346210e-19 1.691000088704906148e+03 1.246051260141436208e-19 1.279511826898118240e-19 1.925575578084424534e-20 3.043350955000408662e-29 2.803148955253303547e-21 8.901320717778166564e-26 2.478780480419308484e-24 1.282444549046748686e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.930806942001858374e-21 0.000000000000000000e+00 7.371155867968684152e-21 1.297740344077554254e-19 1.692950098201361470e+03 1.287226082346942667e-19 1.280931811958323710e-19 1.914235462756107692e-20 3.027015026388594666e-29 2.801734242481365149e-21 8.869399175063195014e-26 2.472907251742394419e-24 1.282291607294675556e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.897864779403407252e-21 0.000000000000000000e+00 7.381424324807672203e-21 1.298963318813484148e-19 1.694900088500794254e+03 1.267339924727618799e-19 1.282351844469517724e-19 2.198724030986138091e-20 3.010679269284009058e-29 2.800335231646498257e-21 8.837477950929031017e-26 2.467034080884943798e-24 1.282138667048289943e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.890148894247345159e-21 0.000000000000000000e+00 7.391692680558026531e-21 1.304857003825812490e-19 1.696800088401695120e+03 1.283668812770892847e-19 1.283735531594955134e-19 2.129066123184151719e-20 2.994991722932419497e-29 2.798994055245862195e-21 8.806375070824213737e-26 2.461311475982562277e-24 1.281989647613175253e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.878093332789634965e-21 0.000000000000000000e+00 7.401836703934815097e-21 1.305062391058268837e-19 1.698700088302817676e+03 1.262034536343274850e-19 1.285119276659816212e-19 2.117036790616792132e-20 2.979304176579000401e-29 2.797652878845069652e-21 8.775272194912239017e-26 2.455588871079513295e-24 1.281840628178081439e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.969430288631601093e-21 0.000000000000000000e+00 7.412010166454704838e-21 1.306274932985075258e-19 1.700600088204161011e+03 1.265208441767054697e-19 1.286503079477144199e-19 1.918439852311608069e-20 2.963722257983039280e-29 2.796284249734236230e-21 8.744169323237893882e-26 2.449866266175799425e-24 1.281691608743008879e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.820660658348223443e-21 0.000000000000000000e+00 7.422183628975777220e-21 1.304506562921478352e-19 1.702550097647643497e+03 1.282387218440057002e-19 1.287923364966857072e-19 2.124443896680028820e-20 2.948136626949575489e-29 2.794869537000729162e-21 8.712247803151671869e-26 2.443993037658433738e-24 1.281538666995289404e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.986695381217150613e-21 0.000000000000000000e+00 7.432624865301619506e-21 1.309172647297901914e-19 1.704500088002344455e+03 1.274319112677901838e-19 1.289343696988430090e-19 1.995219922809290676e-20 2.932551148484965103e-29 2.793458761410109616e-21 8.680326600112532304e-26 2.438119866634520994e-24 1.281385726744768119e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.929422610231218517e-21 0.000000000000000000e+00 7.443065999417456863e-21 1.308516893082478059e-19 1.706400087904358088e+03 1.284514254540965045e-19 1.290727674954592692e-19 2.005581699225930530e-20 2.917347219966578516e-29 2.792117585008688512e-21 8.649223741657894213e-26 2.432397261728788212e-24 1.281236707309760070e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.075459768779518665e-21 0.000000000000000000e+00 7.453239461942116290e-21 1.310111239096730169e-19 1.708350097316121264e+03 1.266651206417901364e-19 1.292148139593776232e-19 2.240724416216709489e-20 2.901717710568145245e-29 2.790741107776855849e-21 8.617302235818265395e-26 2.426524033306957890e-24 1.281083765564648688e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.047986205688466280e-21 0.000000000000000000e+00 7.463680698098120142e-21 1.315304786794580681e-19 1.710300087703909412e+03 1.278192718600065301e-19 1.293568650219418222e-19 2.115117260710122562e-20 2.886088353648666478e-29 2.789364643973711158e-21 8.585381046117269670e-26 2.420650862183390042e-24 1.280930825311652846e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.133452527142273102e-21 0.000000000000000000e+00 7.474121832391120485e-21 1.314666258515506504e-19 1.712200087606585839e+03 1.304090935804776821e-19 1.294952801622033571e-19 1.959598110302791162e-20 2.871197098340034757e-29 2.788023467571821737e-21 8.554278201324648220e-26 2.414928257275661124e-24 1.280781805876710060e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.134938759544873405e-21 0.000000000000000000e+00 7.484295294919330845e-21 1.313624592189559961e-19 1.714150096986842073e+03 1.279792763523645728e-19 1.296373443660935163e-19 2.158582518715444838e-20 2.856073692257602723e-29 2.786646990362229051e-21 8.522356710188621613e-26 2.409055028948726624e-24 1.280628864134190220e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.038805776779048723e-21 0.000000000000000000e+00 7.494736530906632262e-21 1.318098348824101620e-19 1.716100087407491628e+03 1.298467203368115401e-19 1.297794131148274880e-19 2.113101529417167194e-20 2.840950433217453169e-29 2.785239152272996311e-21 8.495155725459388489e-26 2.403842255328104725e-24 1.280475923878737314e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.126548422482562066e-21 0.000000000000000000e+00 7.505336973048183414e-21 1.318805434321388605e-19 1.718050096766680326e+03 1.269703340103063128e-19 1.299214891500707408e-19 1.928337236078168136e-20 2.826021482494710113e-29 2.783824439600643537e-21 8.468667937450617600e-26 2.398729250401788290e-24 1.280322982137950810e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.075620048393558237e-21 0.000000000000000000e+00 7.516033234766351887e-21 1.317354721339140505e-19 1.720000087209300318e+03 1.291523088532860089e-19 1.300635696943747259e-19 2.006201773132596703e-20 2.811114888888904693e-29 2.782423016547407286e-21 8.442180408643857754e-26 2.393616295075494926e-24 1.280162951353721511e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.092179737845638305e-21 0.000000000000000000e+00 7.526729392722674810e-21 1.319930442378179407e-19 1.721950096547516068e+03 1.286160779340036567e-19 1.302056574835429107e-19 1.952133340225699020e-20 2.796235939342046040e-29 2.781073010082488633e-21 8.415692625442042573e-26 2.388503290204170321e-24 1.279975450664016222e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.137571344357173903e-21 0.000000000000000000e+00 7.537425654325802071e-21 1.320547272004265638e-19 1.723900087012005770e+03 1.291271133676879858e-19 1.303477497463172631e-19 1.976247135313578657e-20 2.781546011176223019e-29 2.779723016683995797e-21 8.389205100903012543e-26 2.383390334820533404e-24 1.279787951789151020e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.179183928522675640e-21 0.000000000000000000e+00 7.548121812402086355e-21 1.322331740440652296e-19 1.725850096329342477e+03 1.295477943119211358e-19 1.304898492126575216e-19 1.975255212638330289e-20 2.766855940985619130e-29 2.778373010233532151e-21 8.362717322592951670e-26 2.378277330003954510e-24 1.279620645239315355e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.123794271487530380e-21 0.000000000000000000e+00 7.558818073890686987e-21 1.323697754067905485e-19 1.727800086815601617e+03 1.317931209665435789e-19 1.306319531174676189e-19 2.166807983726748412e-20 2.752243800079756229e-29 2.777023016819968161e-21 8.336229802410173986e-26 2.373164374563237424e-24 1.279470646137836332e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.221017320456299718e-21 0.000000000000000000e+00 7.569514232086381937e-21 1.328140066745174337e-19 1.729750096112152505e+03 1.296803415674945016e-19 1.307740641848877109e-19 2.260736725906131897e-20 2.737770397745356687e-29 2.775673010383894447e-21 8.309742029078873518e-26 2.368051369801159958e-24 1.279320645589452597e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.108361367055055296e-21 0.000000000000000000e+00 7.580210493460967517e-21 1.331054529879384260e-19 1.731700086620082175e+03 1.313096732247901424e-19 1.309161796559562504e-19 2.164092393553672882e-20 2.723297134864279100e-29 2.774323016955327763e-21 8.283254513343089687e-26 2.362938414303621680e-24 1.279170646486384682e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.073618900453113854e-21 0.000000000000000000e+00 7.590906651775529960e-21 1.330835059132941266e-19 1.733650095895939558e+03 1.278100924069854591e-19 1.310583022490174278e-19 2.136001249200367853e-20 2.709096038216812393e-29 2.772973010533580410e-21 8.256766745079835538e-26 2.357825409595803563e-24 1.279020645939670901e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.099728722726276996e-21 0.000000000000000000e+00 7.601602913036606044e-21 1.331797471768427135e-19 1.735650095785437998e+03 1.305755855978385095e-19 1.312040742674763899e-19 2.177281455234055935e-20 2.694725129919906970e-29 2.771588395225466024e-21 8.229599936523361009e-26 2.352581327438222268e-24 1.278866799965455437e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.089598593425224545e-21 0.000000000000000000e+00 7.612692580478980025e-21 1.333900973286098592e-19 1.737600086325964867e+03 1.312113217299789468e-19 1.313462070936312150e-19 1.971827150458918803e-20 2.680713561526884692e-29 2.770238401774332105e-21 8.203112427692682394e-26 2.347468371855212693e-24 1.278716800859998353e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.048234255847511645e-21 0.000000000000000000e+00 7.623649681228545262e-21 1.332090344686285083e-19 1.739550095570690928e+03 1.283798620517555745e-19 1.314883469809677048e-19 2.133814918262234765e-20 2.666667829701613065e-29 2.768888395374137112e-21 8.176624667271434601e-26 2.342355367229022006e-24 1.278566800315797873e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.073721294366874020e-21 0.000000000000000000e+00 7.634606887078001898e-21 1.336000778312321674e-19 1.741550095460937428e+03 1.321479412995187235e-19 1.316341366811764303e-19 2.166947185578402115e-20 2.652253015677836932e-29 2.767503780065504755e-21 8.149457866389036040e-26 2.337111285069479472e-24 1.278412954341646543e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.058678327633421693e-21 0.000000000000000000e+00 7.645844993028315585e-21 1.337967559448495805e-19 1.743500086033837988e+03 1.311522805728779292e-19 1.317762866926987683e-19 1.908903227022651413e-20 2.638221945407632825e-29 2.766153786591958204e-21 8.122970364684698943e-26 2.331998329401584879e-24 1.278262955233817782e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.097982298478070274e-21 0.000000000000000000e+00 7.656802093959789420e-21 1.335457916309882327e-19 1.745450095247641229e+03 1.308059877611464119e-19 1.319184437053467382e-19 2.195819031715241890e-20 2.624621517509179273e-29 2.764803780213171501e-21 8.096482612323663237e-26 2.326885324856475017e-24 1.278112954692114241e-21 0.000000000000000000e+00 0.000000000000000000e+00 5.992148934884629170e-21 0.000000000000000000e+00 7.667759299635489558e-21 1.341216463188138487e-19 1.747450095138628058e+03 1.305895104471170188e-19 1.320642509147446727e-19 2.137052382593668789e-20 2.610672427360406062e-29 2.763419164904026817e-21 8.069315819345147494e-26 2.321641242694991081e-24 1.277959108718027422e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.058051774175990029e-21 0.000000000000000000e+00 7.678997405589963555e-21 1.341737765775498650e-19 1.749450095029864087e+03 1.313873972068704455e-19 1.322100640206924548e-19 2.191649958357888151e-20 2.596779346885661919e-29 2.762034549594709477e-21 8.042149029099689407e-26 2.316397160532853643e-24 1.277805262743962985e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.007935154091411785e-21 0.000000000000000000e+00 7.690235511545836860e-21 1.344036108737642232e-19 1.751400085645767149e+03 1.305047500613081913e-19 1.323522367811673215e-19 2.187771282613061120e-20 2.583377593198182913e-29 2.760692394655705186e-21 8.015661537299051781e-26 2.311284204752204896e-24 1.277656134583604801e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.041078409258094709e-21 0.000000000000000000e+00 7.701192612718944185e-21 1.345392349039135389e-19 1.753350094818487833e+03 1.294716743647737901e-19 1.324944164635154178e-19 2.001862580238155671e-20 2.569975711974756693e-29 2.759367860123291240e-21 7.989173796087772847e-26 2.306171200314815133e-24 1.277508964244057270e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.029448798392797869e-21 0.000000000000000000e+00 7.712149818163799051e-21 1.343897072923350893e-19 1.755350094710453959e+03 1.321696930222627203e-19 1.326402468510634377e-19 2.221813395844044497e-20 2.556320085308051055e-29 2.758009369630634862e-21 7.962007014068464405e-26 2.300927118150763843e-24 1.277358021024283659e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.230531317214860550e-21 0.000000000000000000e+00 7.723438531314092962e-21 1.348880641459631923e-19 1.757350094602666331e+03 1.346161408592691627e-19 1.327860830586763196e-19 2.140598191477068689e-20 2.542763722402291771e-29 2.756674465828428068e-21 7.934840234894397566e-26 2.295683035986066399e-24 1.277183491140223205e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.038978006033908658e-21 0.000000000000000000e+00 7.734886214685142134e-21 1.348921350300665599e-19 1.759350094495123585e+03 1.331766519242288905e-19 1.329319250671988608e-19 1.946566270180663203e-20 2.529207359494872228e-29 2.755353711182465832e-21 7.907673458594943616e-26 2.290438953820726841e-24 1.276994812115572959e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.160280055478961984e-21 0.000000000000000000e+00 7.746333898057595128e-21 1.347478614330864682e-19 1.761350094387825038e+03 1.303518994969348212e-19 1.330777728575592028e-19 1.986257108845344525e-20 2.515971523942690840e-29 2.754032956536342223e-21 7.880506685199883659e-26 2.285194871654747373e-24 1.276806133090961833e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.134386933659622724e-21 0.000000000000000000e+00 7.757781581431444421e-21 1.349490428782084764e-19 1.763350094280770008e+03 1.307437122053900054e-19 1.332236264107682061e-19 2.208502936311777717e-20 2.502857238930379858e-29 2.752675407658344857e-21 7.853339914739395988e-26 2.279950789488129097e-24 1.276654248257026678e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.174813860291641382e-21 0.000000000000000000e+00 7.769229264806688509e-21 1.354399478690018977e-19 1.765350094173957359e+03 1.318748216133423937e-19 1.333694857079189441e-19 2.228591963308786913e-20 2.489742953916479523e-29 2.751316917164859051e-21 7.826173147244095113e-26 2.274706707320875320e-24 1.276503305037386039e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.251115534921807145e-21 0.000000000000000000e+00 7.780676948183318364e-21 1.356204133666353310e-19 1.767350094067386635e+03 1.339696769651140804e-19 1.335153507301865350e-19 2.121981361757325873e-20 2.476596472458781491e-29 2.749958426671208863e-21 7.799006382745005360e-26 2.269462625152987143e-24 1.276352361817767028e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.197105564717943272e-21 0.000000000000000000e+00 7.792124631561333985e-21 1.355910839475803893e-19 1.769350093961056700e+03 1.305488615663575927e-19 1.336612214588273953e-19 2.227339154484550969e-20 2.463447382248761751e-29 2.748599936177395423e-21 7.771839621273596458e-26 2.264218542984467873e-24 1.276201418598169834e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.283038035764629465e-21 0.000000000000000000e+00 7.803572314940727851e-21 1.359079905576260971e-19 1.771350093854966872e+03 1.324538377435726399e-19 1.338070978751790230e-19 1.909716120866225891e-20 2.450369402009782552e-29 2.747241445683418730e-21 7.744672862861775502e-26 2.258974460815318611e-24 1.276050475378594458e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.320586253968989363e-21 0.000000000000000000e+00 7.815019998321496950e-21 1.355700593850314599e-19 1.773350093749116695e+03 1.315368184284356841e-19 1.339529799606594923e-19 2.082997622605495683e-20 2.437626545541342136e-29 2.745908428656243723e-21 7.717506107541893841e-26 2.253730378645541562e-24 1.275899532159040711e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.264255598487862384e-21 0.000000000000000000e+00 7.826467681703636770e-21 1.359667282179533007e-19 1.775350093643504579e+03 1.355441794604593759e-19 1.340988676967668998e-19 2.178553052933039323e-20 2.424883689071384674e-29 2.744587674009006311e-21 7.690339355346771187e-26 2.248486296475139664e-24 1.275748588939508969e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.337337085452115030e-21 0.000000000000000000e+00 7.837937212463859273e-21 1.362639756505902982e-19 1.777350093538130295e+03 1.327691164382147136e-19 1.342447610650792201e-19 2.048289304119074932e-20 2.412215841953725290e-29 2.743265974200515159e-21 7.663172606309682983e-26 2.243242214304114754e-24 1.275597645719999232e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.244011562691892608e-21 0.000000000000000000e+00 7.849692427935388026e-21 1.362019192044013184e-19 1.779350093432992935e+03 1.338288368492256121e-19 1.343906600472535592e-19 2.079327166952780814e-20 2.399672985470229890e-29 2.741907483705891474e-21 7.636005860464379921e-26 2.237998132132468301e-24 1.275446702500511500e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.250928679308240765e-21 0.000000000000000000e+00 7.861447643408308565e-21 1.363936616893090835e-19 1.781350093328091589e+03 1.338813191965774536e-19 1.345365646250260106e-19 2.180331344353589934e-20 2.387130128985254438e-29 2.740548993211107546e-21 7.608839117845095980e-26 2.232754049960202877e-24 1.275295759281045962e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.358557249063033379e-21 0.000000000000000000e+00 7.873202858882617880e-21 1.367005020649756433e-19 1.783400102799892466e+03 1.336026978159464493e-19 1.346861233042511145e-19 2.126060248675841622e-20 2.374376506966379486e-29 2.739166598133404991e-21 7.580993079928482166e-26 2.227378840616246561e-24 1.275127343297887025e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.401098364547599894e-21 0.000000000000000000e+00 7.885252011047300079e-21 1.367649270710117280e-19 1.785450093113778394e+03 1.346979521227542001e-19 1.348356864260336990e-19 1.972546406322984956e-20 2.361695852596199172e-29 2.737799937924147747e-21 7.553147305708012406e-26 2.222003681505132986e-24 1.274937529592371432e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.338704798929607249e-21 0.000000000000000000e+00 7.897301050609266661e-21 1.366800052240592408e-19 1.787450093009592365e+03 1.335847153146029644e-19 1.349816079583909225e-19 2.076928371092303961e-20 2.349324424669235625e-29 2.736466604660271940e-21 7.525980573144665932e-26 2.216759599330992282e-24 1.274752344624150540e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.366893961449092011e-21 0.000000000000000000e+00 7.909056266087779920e-21 1.369802956288686891e-19 1.789450092905639167e+03 1.342290495804184326e-19 1.351275350131750760e-19 2.428458684084398803e-20 2.337106219653498498e-29 2.735142391477408149e-21 7.498813843951090976e-26 2.211515517156241055e-24 1.274591986515785442e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.328670438681457441e-21 0.000000000000000000e+00 7.920811481567660890e-21 1.376992694038189180e-19 1.791500102335098290e+03 1.349255162101505910e-19 1.352771166526741200e-19 1.984119568981700131e-20 2.324615805058294046e-29 2.733788611665500940e-21 7.470967820535559145e-26 2.206140307923306507e-24 1.274437268996294318e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.403693267021956237e-21 0.000000000000000000e+00 7.932860633483473820e-21 1.371371820366369345e-19 1.793550092693259785e+03 1.324747237605072248e-19 1.354267026646264815e-19 2.065754505419443336e-20 2.312139443840441616e-29 2.732437902883998180e-21 7.443122059794934248e-26 2.200765148696100375e-24 1.274282902451355513e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.372143307166334978e-21 0.000000000000000000e+00 7.944909673305675667e-21 1.374043004457312288e-19 1.795550092590011673e+03 1.355813232738644414e-19 1.355726464527525437e-19 2.182476218914485452e-20 2.300139444459930107e-29 2.731141606654622183e-21 7.416114428848378740e-26 2.195544813187775746e-24 1.274134754476874870e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.392817385867053726e-21 0.000000000000000000e+00 7.956664888789700396e-21 1.377298874600984680e-19 1.797550092486993890e+03 1.377406011266326601e-19 1.357185956913989191e-19 2.249303708773452530e-20 2.288139445078036637e-29 2.729845310425096475e-21 7.393495161688962981e-26 2.190979518463446659e-24 1.273986606502415856e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.345230095570689647e-21 0.000000000000000000e+00 7.968696753609408769e-21 1.379793865361437963e-19 1.799600101874488018e+03 1.353264973224599142e-19 1.358681999920196845e-19 2.224093737593249172e-20 2.275948881024908323e-29 2.728499932083674700e-21 7.370310307286678914e-26 2.186300069701637281e-24 1.273818085590903813e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.545074872808973485e-21 0.000000000000000000e+00 7.981067146425503711e-21 1.380957270573493691e-19 1.801650092276521946e+03 1.337360237572333407e-19 1.360178085962463701e-19 2.234367216331525809e-20 2.264022971949216375e-29 2.727133271815652143e-21 7.347125669441755248e-26 2.181620664276940500e-24 1.273628271877663435e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.340937414953733031e-21 0.000000000000000000e+00 7.993437424677440747e-21 1.382506631443460654e-19 1.803700101642916479e+03 1.366345236363420781e-19 1.361674242549100655e-19 2.173431155000063467e-20 2.252096952547524809e-29 2.725766598904722158e-21 7.323940818973126421e-26 2.176941215563294064e-24 1.273438456408528841e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.395208610014417618e-21 0.000000000000000000e+00 8.005807817366213664e-21 1.383039798145438992e-19 1.805750092067005880e+03 1.353535996060532890e-19 1.363170441828014706e-19 2.079284973782659024e-20 2.240159463380880136e-29 2.724430495882495884e-21 7.300756184608901221e-26 2.172261810088252697e-24 1.273279199919579030e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.371626179829014567e-21 0.000000000000000000e+00 8.018178095751238478e-21 1.383062243764836635e-19 1.807800101412395406e+03 1.396748897824510489e-19 1.364666711248314866e-19 2.075169385796849855e-20 2.228210837482038221e-29 2.723101786121595479e-21 7.277571338143599780e-26 2.167582361422553206e-24 1.273127347545916031e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.351200207894082268e-21 0.000000000000000000e+00 8.030548488313261130e-21 1.384472777639778239e-19 1.809850091858439100e+03 1.373830051564475473e-19 1.366163023020225208e-19 2.239207689984476998e-20 2.216262321739383492e-29 2.721777214271902513e-21 7.254386707332859565e-26 2.162902955897397943e-24 1.272975968075900483e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.427766884002556496e-21 0.000000000000000000e+00 8.042918766830765850e-21 1.388540688481037215e-19 1.811900101182917524e+03 1.384983196601124539e-19 1.367659404533898900e-19 2.196948961219231836e-20 2.204600831914044713e-29 2.720472662883597953e-21 7.231201864942381741e-26 2.158223507279431237e-24 1.272826876656085987e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.340913637833962590e-21 0.000000000000000000e+00 8.055289159266605484e-21 1.389305469490164751e-19 1.813950091650815011e+03 1.373699299150678282e-19 1.369155828061597588e-19 2.130867362753468327e-20 2.193020184007676596e-29 2.719168123494936080e-21 7.208017237759753182e-26 2.153544101704391299e-24 1.272677786607696676e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.404881875738637713e-21 0.000000000000000000e+00 8.067659437915982239e-21 1.389786300703775196e-19 1.816000100954476238e+03 1.376738888633262493e-19 1.370652320934761983e-19 2.012793574023649701e-20 2.181439438197195329e-29 2.717851786418395057e-21 7.184832399517468648e-26 2.148864653133942851e-24 1.272508827886439356e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.359298219055220762e-21 0.000000000000000000e+00 8.080029830226203092e-21 1.389487142926143898e-19 1.818050091444127247e+03 1.363750380162090613e-19 1.372148855487413973e-19 1.976554907779286035e-20 2.170031420946014797e-29 2.716523088878806610e-21 7.161647776039480560e-26 2.144185247509247461e-24 1.272319014165524411e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.455704575818031885e-21 0.000000000000000000e+00 8.092580758353655431e-21 1.390495092741086792e-19 1.820100100727063591e+03 1.380155891336505513e-19 1.373645458992523999e-19 2.367706181355143845e-20 2.158623299111850133e-29 2.715194379158384588e-21 7.138462942020720826e-26 2.139505798986106782e-24 1.272129198704556023e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.384476491343611870e-21 0.000000000000000000e+00 8.105206499124829797e-21 1.398036774784194418e-19 1.822150091238370123e+03 1.388733503062022817e-19 1.375142103845600946e-19 2.097934658078718081e-20 2.147295715467813678e-29 2.713854485734885186e-21 7.115278322325843197e-26 2.134826393311979283e-24 1.271974151064909146e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.293941196753100774e-21 0.000000000000000000e+00 8.117832124283976363e-21 1.395162602129420370e-19 1.824200100500673443e+03 1.361361593108472017e-19 1.376638817261382598e-19 2.202796379760631626e-20 2.136253941441200678e-29 2.712512661490468200e-21 7.092093492607938342e-26 2.130146944835936255e-24 1.271825059649880134e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.368675081797645888e-21 0.000000000000000000e+00 8.130457864928075464e-21 1.398292357013774792e-19 1.826300100385111136e+03 1.360113563990936916e-19 1.378172085580655420e-19 2.246306592545630744e-20 2.124942907580884256e-29 2.711140675676317026e-21 7.068343289993517134e-26 2.125353385392267708e-24 1.271671793702240016e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.384024495382476383e-21 0.000000000000000000e+00 8.143391491317527328e-21 1.400507420069010611e-19 1.828350090928977579e+03 1.392129236000887918e-19 1.379668895867130322e-19 1.870311809189232261e-20 2.113886526208331693e-29 2.709811978101588634e-21 7.045158676173053137e-26 2.120673979643817375e-24 1.271519942721711797e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.400327351199188722e-21 0.000000000000000000e+00 8.156017116677206836e-21 1.396463887912079108e-19 1.830400100160253714e+03 1.395064324784975258e-19 1.381165774133036508e-19 2.333941434878458696e-20 2.102809283344594267e-29 2.708483268414650333e-21 7.021973853110395516e-26 2.115994531238598616e-24 1.271368090356973339e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.148466962796682361e-21 0.000000000000000000e+00 8.168642857130213061e-21 1.404791794307901123e-19 1.832500100045472436e+03 1.403926368734813946e-19 1.382699210790380624e-19 2.281707424466023246e-20 2.091461915543763230e-29 2.707136299971062713e-21 6.998223657009972810e-26 2.111200971793146992e-24 1.271192331303320889e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.294108110553215243e-21 0.000000000000000000e+00 8.181576483524475237e-21 1.405513730431143653e-19 1.834600099930954229e+03 1.385595168218488717e-19 1.384232704091133575e-19 2.425199421185462528e-20 2.080351201051074121e-29 2.705799936407574444e-21 6.974473463160573572e-26 2.106407412347095131e-24 1.271001422437810083e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.130152667922325746e-21 0.000000000000000000e+00 8.194510109920357902e-21 1.409355405284042947e-19 1.836650090518060779e+03 1.397903309104618838e-19 1.385729733310624485e-19 1.954417607276623901e-20 2.069620560667530241e-29 2.704495396943052373e-21 6.951288857505239125e-26 2.101728006499942945e-24 1.270815059867094199e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.379131078718611972e-21 0.000000000000000000e+00 8.207135735546346878e-21 1.403617590982898215e-19 1.838700099708124526e+03 1.355409300019190738e-19 1.387226829740041611e-19 2.263105605735693889e-20 2.058889822907127452e-29 2.703212437682422307e-21 6.928104043649365500e-26 2.097048558188797529e-24 1.270665710492930007e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.357657784646608718e-21 0.000000000000000000e+00 8.219951761301979942e-21 1.409718299607250847e-19 1.840800099594376661e+03 1.364716978848203435e-19 1.388760489179697489e-19 2.207289478108398893e-20 2.048046383468969883e-29 2.701899937753514853e-21 6.904353856581930409e-26 2.092254998740987202e-24 1.270515710670108217e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.357082966763211810e-21 0.000000000000000000e+00 8.233268182900629562e-21 1.410350429280893231e-19 1.842900099480888002e+03 1.394392003343890740e-19 1.390294204524328884e-19 2.061569901072512892e-20 2.037227763363976861e-29 2.700581754875798801e-21 6.880603671858752478e-26 2.087461439292585087e-24 1.270355968660612046e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.410326604541621844e-21 0.000000000000000000e+00 8.246584604500922241e-21 1.409687631793666911e-19 1.845000099367657640e+03 1.373814841512890559e-19 1.391827975589123316e-19 2.146194278897681240e-20 2.026422943214043537e-29 2.699245391311490883e-21 6.856853489504234694e-26 2.082667879843593387e-24 1.270165059795267691e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.400523970360278291e-21 0.000000000000000000e+00 8.259901026102853466e-21 1.412464443657344185e-19 1.847100099254685119e+03 1.376753685697159409e-19 1.393361802190076237e-19 2.208890684545859448e-20 2.015749150684807111e-29 2.697909027747018585e-21 6.833103309543108357e-26 2.077874320394013206e-24 1.269974150929964149e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.559361595032518833e-21 0.000000000000000000e+00 8.273217447706420226e-21 1.415021336479093651e-19 1.849200099141968849e+03 1.412040428219213014e-19 1.394895684143984762e-19 2.162893032781985702e-20 2.005075358154268319e-29 2.696596302348601046e-21 6.809353132000465218e-26 2.073080760943848217e-24 1.269806880204245867e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.524607341246980834e-21 0.000000000000000000e+00 8.286533869311610485e-21 1.415813247342978229e-19 1.851250089804184427e+03 1.406153566797154363e-19 1.396393091575521999e-19 2.320666125240845475e-20 1.994705067601117584e-29 2.695329035393777166e-21 6.786168541597672773e-26 2.068401354925248711e-24 1.269657790142521936e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.543842312306404816e-21 0.000000000000000000e+00 8.299533174744944093e-21 1.419798110486328726e-19 1.853300098922639791e+03 1.404760986776339573e-19 1.397890564894106061e-19 2.160253700328655342e-20 1.984440884014920621e-29 2.694061757029640851e-21 6.762983744817716558e-26 2.063721906777559826e-24 1.269508698738567210e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.455587798078999734e-21 0.000000000000000000e+00 8.312532597212127796e-21 1.418706888561791782e-19 1.855400098810676127e+03 1.411756541148477242e-19 1.399424609209805614e-19 2.190985370733167868e-20 1.973926401816890766e-29 2.692749938243327347e-21 6.739233574565109414e-26 2.058928347325676778e-24 1.269358569174413950e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.621594659359961981e-21 0.000000000000000000e+00 8.325849018822090750e-21 1.420773082285299548e-19 1.857500098698965530e+03 1.379183807298865518e-19 1.400958708162146038e-19 2.109165746675366348e-20 1.963487788493384226e-29 2.691437438313146597e-21 6.715483406833619673e-26 2.054134787873215901e-24 1.269208569351795098e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.688437293383302842e-21 0.000000000000000000e+00 8.339165440433659147e-21 1.421085593418624681e-19 1.859600098587507318e+03 1.370668743194648008e-19 1.402492861571836735e-19 2.179896003602917666e-20 1.953118133871343584e-29 2.690124938382807861e-21 6.691733241650131026e-26 2.049341228420179032e-24 1.269047853495099384e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.710097345202072790e-21 0.000000000000000000e+00 8.352600983832824637e-21 1.423681689657911158e-19 1.861750108097217435e+03 1.403597415516725849e-19 1.404063605705816232e-19 2.111198553222031067e-20 1.942501535188912849e-29 2.688781182439239080e-21 6.667417490172780278e-26 2.044433514631419485e-24 1.268855888577211972e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.567797063400235439e-21 0.000000000000000000e+00 8.366632574221181137e-21 1.424136161481199711e-19 1.863900098360066977e+03 1.380912877541199878e-19 1.405634392481652219e-19 2.209420725816528565e-20 1.932154106143408720e-29 2.687437438524958013e-21 6.643101959101762514e-26 2.039525844776457877e-24 1.268663925377858369e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.641579380234811353e-21 0.000000000000000000e+00 8.380664038998900087e-21 1.427214503371639176e-19 1.866000098249372513e+03 1.405163221901982860e-19 1.407168710758815024e-19 2.267321492502628619e-20 1.922116818536897266e-29 2.686124938594142308e-21 6.619351801853432412e-26 2.034732285321677602e-24 1.268501427325914351e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.643425241634247312e-21 0.000000000000000000e+00 8.394369251989471025e-21 1.429641122159823779e-19 1.868100098138926342e+03 1.415755998135585284e-19 1.408703082775523660e-19 2.618077459483956359e-20 1.912079529609973097e-29 2.684812438663170874e-21 6.595601647265909537e-26 2.029938725866330519e-24 1.268351427503434113e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.701467037314384994e-21 0.000000000000000000e+00 8.408074464981660947e-21 1.437160360800379758e-19 1.870200098028728917e+03 1.393983594412113409e-19 1.410237508356370207e-19 2.061690176888729051e-20 1.902014012896781769e-29 2.683499940482557172e-21 6.571851495368064674e-26 2.025145166410415526e-24 1.268201425930465428e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.714477061798327063e-21 0.000000000000000000e+00 8.421779677975475872e-21 1.429600469514136391e-19 1.872300097918778420e+03 1.386868155198010174e-19 1.411771987326699539e-19 2.088886724977552442e-20 1.891948496182406904e-29 2.682224940549313039e-21 6.548101346189218600e-26 2.020351606953937397e-24 1.268013926152427479e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.621044342288775825e-21 0.000000000000000000e+00 8.435484890970900755e-21 1.431472809540775546e-19 1.874400097809074168e+03 1.391834248369884871e-19 1.413306519512611739e-19 2.228474285047350332e-20 1.881957511869723800e-29 2.680949940615919195e-21 6.524351199759097318e-26 2.015558047496896500e-24 1.267826426374430531e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.674285803953511476e-21 0.000000000000000000e+00 8.449190103967934090e-21 1.435119950728312046e-19 1.876550107244675019e+03 1.415828633387330630e-19 1.414877650106686772e-19 2.370740285453853625e-20 1.871972722287441583e-29 2.679631182972078053e-21 6.500035468551076907e-26 2.010650333877302346e-24 1.267647856220637925e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.694047481917395877e-21 0.000000000000000000e+00 8.463221693872630900e-21 1.438959775301674798e-19 1.878700097585207232e+03 1.404107981871684908e-19 1.416448822159831291e-19 2.538898369809120045e-20 1.861988021383952715e-29 2.678287439009245496e-21 6.475719956249052316e-26 2.005742663845018516e-24 1.267494285655932274e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.790841869959707270e-21 0.000000000000000000e+00 8.477253159157331348e-21 1.443420668932873540e-19 1.880800097476248766e+03 1.421805995128794670e-19 1.417983515461735420e-19 2.381371107437598633e-20 1.852303282735810509e-29 2.676974939077344575e-21 6.452757776145255780e-26 2.001070837562956164e-24 1.267344285833615477e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.608350186068959558e-21 0.000000000000000000e+00 8.491002492108727643e-21 1.442165216340365048e-19 1.882950106880158501e+03 1.415406888866571386e-19 1.419554810443001132e-19 2.241484182825322669e-20 1.842464256650122194e-29 2.675675374843414224e-21 6.432553905581823349e-26 1.996798372332873327e-24 1.267165461568216118e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.824569099938826813e-21 0.000000000000000000e+00 8.505354503216126023e-21 1.441577763505644381e-19 1.885100097253900913e+03 1.423372928117678770e-19 1.421126146383386584e-19 2.298187131758754179e-20 1.832625317651640279e-29 2.674392924445041532e-21 6.412350215397608750e-26 1.992525944919243091e-24 1.266976866135130751e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.715416131278054586e-21 0.000000000000000000e+00 8.519706387290977290e-21 1.443973734913931553e-19 1.887200097145680729e+03 1.409252715439612190e-19 1.422660999214002200e-19 2.017829105694742087e-20 1.823116850156761609e-29 2.673137439283949548e-21 6.392616292646265294e-26 1.988352857813441982e-24 1.266794286480540388e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.721182095816158678e-21 0.000000000000000000e+00 8.533724568661512528e-21 1.441303430790851963e-19 1.889350106518111716e+03 1.415732219937595784e-19 1.424232456964517587e-19 2.309654571458585527e-20 1.813423587562411486e-29 2.671793683426180193e-21 6.372412427038100599e-26 1.984080392645913444e-24 1.266640714556648988e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.885180797874646256e-21 0.000000000000000000e+00 8.548076579558779914e-21 1.447309556750539967e-19 1.891500096924836953e+03 1.443158799583808879e-19 1.425803955180996684e-19 2.135388419473054308e-20 1.803730410474463807e-29 2.670449939421977006e-21 6.352208741247681845e-26 1.979807965166740214e-24 1.266487143987491693e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.732315885140059362e-21 0.000000000000000000e+00 8.562428463853802589e-21 1.446116596653400675e-19 1.893600096817347321e+03 1.425196913251666025e-19 1.427338965973609388e-19 2.138653834182216015e-20 1.794546243897583228e-29 2.669163100144038507e-21 6.332474823127168538e-26 1.975634878059487370e-24 1.266322480950617230e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.892337164258406368e-21 0.000000000000000000e+00 8.576446645229212837e-21 1.447761617703160191e-19 1.895750106158509425e+03 1.423150902010734154e-19 1.428910584896469654e-19 2.339701473968631525e-20 1.785157869774508462e-29 2.667880638431766282e-21 6.312270962605898249e-26 1.971362412954095830e-24 1.266133883854009498e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.897649907953444135e-21 0.000000000000000000e+00 8.590798655917751547e-21 1.452424696045307594e-19 1.897900096597991933e+03 1.415555672908668075e-19 1.430482243798823708e-19 2.225187931826551300e-20 1.775787583984647570e-29 2.666598187994180228e-21 6.292067281346700273e-26 1.967089985409827764e-24 1.265945288415506137e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.856754822203838931e-21 0.000000000000000000e+00 8.605150540431437988e-21 1.452161068931060700e-19 1.900050105918262489e+03 1.416311150750979253e-19 1.432053970122808938e-19 2.520392819235743880e-20 1.766528210512015846e-29 2.665286777067733668e-21 6.271863424319693701e-26 1.962817520345951379e-24 1.265756691320858565e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.891490381608414598e-21 0.000000000000000000e+00 8.619502550980518305e-21 1.458544414515337482e-19 1.902200096379628349e+03 1.422854168211243052e-19 1.433625736103138818e-19 2.542769095303680371e-20 1.757268918258400129e-29 2.663966607486193010e-21 6.251659746184691091e-26 1.958545092758197002e-24 1.265568095880562810e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.946351522218927108e-21 0.000000000000000000e+00 8.633854435640285028e-21 1.460509794756364787e-19 1.904350105679100125e+03 1.437205354056354662e-19 1.435197569122895706e-19 2.158802857961412835e-20 1.748005646020964483e-29 2.662650814156326215e-21 6.231455892715334243e-26 1.954272627735651732e-24 1.265383886601813259e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.141864033572058161e-21 0.000000000000000000e+00 8.648653435450435754e-21 1.455969091011177650e-19 1.906500096162249747e+03 1.416167414291826405e-19 1.436769441478784668e-19 2.195869454046206129e-20 1.738735178581756866e-29 2.661368363692693087e-21 6.211252217770555572e-26 1.950000200104609408e-24 1.265233010248143907e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.033968102056528524e-21 0.000000000000000000e+00 8.663474359729204666e-21 1.458028283017177394e-19 1.908650105441015967e+03 1.432082959548256576e-19 1.438341380495077144e-19 2.147406972088864094e-20 1.729464630098399035e-29 2.660085902017639835e-21 6.191048367923913897e-26 1.945727735123209747e-24 1.265082132575526634e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.929407493658339680e-21 0.000000000000000000e+00 8.678295413575250633e-21 1.458814619200083135e-19 1.910850105319619161e+03 1.426279790321967356e-19 1.439949923800364593e-19 2.318642488569756242e-20 1.720147559061861025e-29 2.658773621388297560e-21 6.170374753266725790e-26 1.941355929599742771e-24 1.264909323915275230e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.856966632738605577e-21 0.000000000000000000e+00 8.693461076804751175e-21 1.462991164120393818e-19 1.913000095835509001e+03 1.415728397186712931e-19 1.441521955636601813e-19 2.234313947201435761e-20 1.711146265435335653e-29 2.657491170905135050e-21 6.150171083273529957e-26 1.937083501903639406e-24 1.264720728470484009e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.862552128216486974e-21 0.000000000000000000e+00 8.708282001309215001e-21 1.463238256266455317e-19 1.915150105083149811e+03 1.447285061725958565e-19 1.443094053566261769e-19 2.492187368347179730e-20 1.702144893385212911e-29 2.656208709248647462e-21 6.129967239030498551e-26 1.932811036984092054e-24 1.264532131382622707e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.967718533635842604e-21 0.000000000000000000e+00 8.723103054940698831e-21 1.468999672590397977e-19 1.917350104962575870e+03 1.430428021083616570e-19 1.444702758966094355e-19 2.178774905196659354e-20 1.693182525463135004e-29 2.654915455711593493e-21 6.109293629854557949e-26 1.928439231458989671e-24 1.264373845580489861e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.933718155247662055e-21 0.000000000000000000e+00 8.738268718175873343e-21 1.465586832468904202e-19 1.919500095510981282e+03 1.442700719869361723e-19 1.446274948712259462e-19 2.230276830920862688e-20 1.684469776880088671e-29 2.653655116424597255e-21 6.089089964973853371e-26 1.924166803698271953e-24 1.264225570539031969e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.123127044621270197e-21 0.000000000000000000e+00 8.753089642904482314e-21 1.468009585106566082e-19 1.921650104727705184e+03 1.459134255982944116e-19 1.447847203991943841e-19 2.483316104716568937e-20 1.675756574805516440e-29 2.652388729905695362e-21 6.068886126493375371e-26 1.919894338840161813e-24 1.264071257928609272e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.012761858641200153e-21 0.000000000000000000e+00 8.767910696322839425e-21 1.473566736912223759e-19 1.923850104607945013e+03 5.622238464267220935e-19 1.449456069893453759e-19 2.262855328463167475e-20 1.666824575291742648e-29 2.651061143771067678e-21 6.048212522965618544e-26 1.915522533313442758e-24 1.263881602982508293e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.145560064769526980e-21 0.000000000000000000e+00 8.783076359563623209e-21 1.471669371625623993e-19 1.926050104488457919e+03 5.242979520260401432e-19 1.451064989761464463e-19 2.323576006438416542e-20 1.657892575776860429e-29 2.649733557636275236e-21 6.027538921388569338e-26 1.911150727786180772e-24 1.263691948036448504e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.088809424002378887e-21 0.000000000000000000e+00 8.798617464327365068e-21 1.474180500757608559e-19 1.928250104369243672e+03 2.369811955083859169e-19 1.452673963416662969e-19 2.254710245483296595e-20 1.649042212317729329e-29 2.648413972832380674e-21 6.006865321782392532e-26 1.906778922258376957e-24 1.263500553672616269e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.076355825126761636e-21 0.000000000000000000e+00 8.814269242031809723e-21 1.474698781341137853e-19 1.930400094971678982e+03 1.472925416277804728e-19 1.454246414496786961e-19 2.241375034421821035e-20 1.640583232898312128e-29 2.647131522297594966e-21 5.986661665853951020e-26 1.902506494390291421e-24 1.263311958220712085e-21 0.000000000000000000e+00 0.000000000000000000e+00 6.975662018542665555e-21 0.000000000000000000e+00 8.829565231486110928e-21 1.476005653581916242e-19 1.932550104137018252e+03 5.222737814430671082e-19 1.455818930187088614e-19 2.268104945456594320e-20 1.632124180444518531e-29 2.645849060690199784e-21 5.966457837411858429e-26 1.898234029634292435e-24 1.263123361140548860e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.149882157199901591e-21 0.000000000000000000e+00 8.844861353005167432e-21 1.478055004658867695e-19 1.934750104018604361e+03 1.461323238066924429e-19 1.457428061719021845e-19 2.553424424607870103e-20 1.623455589473241821e-29 2.644556835575300882e-21 5.945784243749304780e-26 1.893862224104898028e-24 1.262966950696886988e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.171002307974315922e-21 0.000000000000000000e+00 8.860513130715305617e-21 1.484300640607723754e-19 1.936950103900459453e+03 1.455516337526924900e-19 1.459037246336716062e-19 2.274180866202410174e-20 1.614772923272853679e-29 2.643267180472144385e-21 5.925110652140190529e-26 1.889490418574968772e-24 1.262815226740191989e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.244992173084126658e-21 0.000000000000000000e+00 8.876164908427357696e-21 1.481382614503287882e-19 1.939150103782582846e+03 1.449361610689178380e-19 1.460646483864718566e-19 2.250494758525481509e-20 1.606090257071406435e-29 2.641982991040545391e-21 5.904437062606119978e-26 1.885118613044506870e-24 1.262654822020703219e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.240338519394084362e-21 0.000000000000000000e+00 8.891816686141317648e-21 1.482613080166762889e-19 1.941350103664972949e+03 7.317272815442357231e-19 1.462255774128342935e-19 2.326227958139946602e-20 1.597622555193349138e-29 2.640715194498150957e-21 5.883763475169006222e-26 1.880746807513514526e-24 1.262468381565508089e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.175856319266809057e-21 0.000000000000000000e+00 8.907468463857176447e-21 1.485343605233581427e-19 1.943550103547629078e+03 2.288557533326904920e-19 1.463865116953665420e-19 2.290755733591604549e-20 1.589226490067408885e-29 2.639447397955603427e-21 5.863089889851067712e-26 1.876375001981993577e-24 1.262281941110353208e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.368815819040807592e-21 0.000000000000000000e+00 8.923120241574926570e-21 1.486480694548239475e-19 1.945750103430551007e+03 3.807565566940164294e-19 1.465474512167521084e-19 2.418573687554763487e-20 1.580830424940454373e-29 2.638167180747608091e-21 5.842416306674825957e-26 1.872003196449944758e-24 1.262093674088899356e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.409307202333937580e-21 0.000000000000000000e+00 8.938772019294569520e-21 1.490116022824887284e-19 1.947950103313737145e+03 1.773344217338281185e-19 1.467083959597498511e-19 2.166746374591640750e-20 1.572663810287749019e-29 2.636877525643671442e-21 5.821742725663136514e-26 1.867631390917370639e-24 1.261904019143221743e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.433741382461912709e-21 0.000000000000000000e+00 8.954656379699688819e-21 1.487844895827968508e-19 1.950150103197187264e+03 1.421730007872830056e-19 1.468693459071937400e-19 2.137072176241753415e-20 1.564502520397531101e-29 2.635587870539580191e-21 5.801069146839174072e-26 1.863259585384271956e-24 1.261714364197586636e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.288135400474705500e-21 0.000000000000000000e+00 8.970703657274753913e-21 1.488940603503415324e-19 1.952350103080899771e+03 1.431795441655374337e-19 1.470303010419922302e-19 2.280805377294884055e-20 1.556340601024332625e-29 2.634298215435334716e-21 5.780395570226453109e-26 1.858887779850652015e-24 1.261560055816427292e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.394032202888274828e-21 0.000000000000000000e+00 8.986750934851732900e-21 1.492718366280527864e-19 1.954550102964874213e+03 4.228974984655091506e-19 1.471912613471280693e-19 2.201532512006748238e-20 1.548175355553318989e-29 2.633008560330935768e-21 5.759721995848814120e-26 1.854515974316511550e-24 1.261408331859972283e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.425398380743007860e-21 0.000000000000000000e+00 9.002798212430622771e-21 1.493139402814362891e-19 1.956750102849109453e+03 5.212052685211399025e-19 1.473522268056577685e-19 2.324787938276133167e-20 1.540010110081337617e-29 2.631725364459835191e-21 5.739048423730448871e-26 1.850144168781852766e-24 1.261246349132734916e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.587760295264415120e-21 0.000000000000000000e+00 9.018845490011414497e-21 1.496682098671123748e-19 1.959000112302192065e+03 5.350446230465587438e-19 1.475168565832128428e-19 2.326476287273297636e-20 1.531706474330339488e-29 2.630428748842804595e-21 5.717904910121361306e-26 1.845672985010204017e-24 1.261055670583652873e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.505168835584828209e-21 0.000000000000000000e+00 9.035257548262760547e-21 1.498297201030142210e-19 1.961250102613126955e+03 1.469796982240369425e-19 1.476814903148114377e-19 2.253289339294933697e-20 1.523473722897541930e-29 2.629132144256842069e-21 5.696761578810494137e-26 1.841201839277533727e-24 1.260864993656851023e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.418792185839027755e-21 0.000000000000000000e+00 9.051669466887116652e-21 1.498767066079771890e-19 1.963450102498150954e+03 1.451997306191387541e-19 1.478424713641525745e-19 2.387732796027963456e-20 1.515423887252667516e-29 2.627888925721373157e-21 5.676088013725307887e-26 1.836830033741307494e-24 1.260678553202037129e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.434515533571717131e-21 0.000000000000000000e+00 9.067716744473662095e-21 1.502448460073008946e-19 1.965650102383432795e+03 1.464324120816101556e-19 1.480034574990887707e-19 2.260472395129417160e-20 1.507534475413625921e-29 2.626658417310961477e-21 5.655414451000877043e-26 1.832458228204568820e-24 1.260492112747264801e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.467693677349624809e-21 0.000000000000000000e+00 9.083764022062088328e-21 1.502090755328540792e-19 1.967850102268970886e+03 1.451581333268646761e-19 1.481644487030429211e-19 2.286358660969192118e-20 1.499728024206877878e-29 2.625427908900406105e-21 5.634740890663232378e-26 1.828086422667321009e-24 1.260305672292533662e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.387377108811796014e-21 0.000000000000000000e+00 9.099811299652383315e-21 1.504038184482366094e-19 1.970100111669455146e+03 1.460815100152547119e-19 1.483291047204174264e-19 2.253109396783731049e-20 1.491744119882578937e-29 2.624132139037940990e-21 5.614846539359562243e-26 1.823818126341266571e-24 1.260114993748235035e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.414377274534922498e-21 0.000000000000000000e+00 9.116455632531899292e-21 1.505182056059239824e-19 1.972350102035640248e+03 1.481325617571058402e-19 1.484937646120214246e-19 2.397542660112532094e-20 1.483873514830442781e-29 2.622835534420139682e-21 5.597266439257640206e-26 1.819925720037064832e-24 1.259924316817076709e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.444017452592757455e-21 0.000000000000000000e+00 9.133461531058079370e-21 1.509056639214386250e-19 1.974550101921954365e+03 1.450976983270425458e-19 1.486547711520637109e-19 2.275025077100990719e-20 1.476194805549823857e-29 2.621567737875483785e-21 5.580076936669369162e-26 1.816119795551595821e-24 1.259750589939793599e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.401609438278349883e-21 0.000000000000000000e+00 9.150089591065153154e-21 1.508733987503169090e-19 1.976800111290972382e+03 1.470874513631687788e-19 1.488194428002370392e-19 2.374366259396692766e-20 1.468350584326585267e-29 2.620271122306897098e-21 5.562496690832910782e-26 1.812227356373143644e-24 1.259598047106636886e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.524841143921293010e-21 0.000000000000000000e+00 9.167095633218724925e-21 1.511955665904954040e-19 1.979050101690202609e+03 1.470050499042220089e-19 1.489841182753348802e-19 2.232968583483236309e-20 1.460599004499559913e-29 2.618974517670052782e-21 5.544916594621431939e-26 1.808334950011774676e-24 1.259445505559608103e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.479328784595581827e-21 0.000000000000000000e+00 9.184101531994666520e-21 1.511410456545745218e-19 1.981300111038204477e+03 1.475792551271543721e-19 1.491488003353194884e-19 2.314437060302251319e-20 1.452847359402622913e-29 2.617719938928987550e-21 5.527336351775115503e-26 1.804442510869679437e-24 1.259268102274252792e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.194230742781569310e-21 0.000000000000000000e+00 9.201107573989394210e-21 1.514129521729720013e-19 1.983550101459501775e+03 1.513008348322524799e-19 1.493134861908206400e-19 2.515715591066512935e-20 1.445170136771313176e-29 2.616482444197273996e-21 5.509756258244138009e-26 1.800550104470135556e-24 1.259080603287643027e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.522275518987263389e-21 0.000000000000000000e+00 9.218113472932122842e-21 1.519124391369735568e-19 1.985800110786581627e+03 1.481560722787903028e-19 1.494781785938263789e-19 2.371610867856524934e-20 1.437641534225658116e-29 2.615242309038241254e-21 5.492176018441592003e-26 1.796657665364234523e-24 1.258892961326363866e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.266639622582677562e-21 0.000000000000000000e+00 9.235119514768716637e-21 1.518311413297416499e-19 1.988050101229845723e+03 1.490647946007171513e-19 1.496428747612284019e-19 2.587472648727100912e-20 1.430112994675081247e-29 2.613945704376021305e-21 5.474595927646955285e-26 1.792765258926688746e-24 1.258702284389097860e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.447849244473845820e-21 0.000000000000000000e+00 9.252125413877475477e-21 1.523547858370108962e-19 1.990300110536097009e+03 1.496429312918413940e-19 1.498075774390654107e-19 2.404628155638044918e-20 1.422589308022990463e-29 2.612649088843605239e-21 5.457015690943212130e-26 1.788872819856820656e-24 1.258511605853341973e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.328825313716771878e-21 0.000000000000000000e+00 9.269131455556644060e-21 1.522122602919890059e-19 1.992550101001226949e+03 1.489868797144452628e-19 1.499722838504630005e-19 2.569571577015426073e-20 1.415069985041061087e-29 2.611377444449325184e-21 5.439435602942188246e-26 1.784980413381447471e-24 1.258322270863380647e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.447910095986143555e-21 0.000000000000000000e+00 9.286271924047557971e-21 1.526501379416130186e-19 1.994800110286742665e+03 1.486908726205778821e-19 1.501369967355354234e-19 2.381501194310182364e-20 1.407550599170756793e-29 2.610139939342291486e-21 5.421855369393734807e-26 1.781087974347451427e-24 1.258134770305078136e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.399187034148516147e-21 0.000000000000000000e+00 9.303878255937355786e-21 1.525056669070440947e-19 1.997050100773638860e+03 1.496606618994089625e-19 1.503017133236141024e-19 2.552023674038115117e-20 1.400201895267749248e-29 2.608902444574498719e-21 5.404275284245051409e-26 1.777195567834423117e-24 1.257947271313389859e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.366266560611181269e-21 0.000000000000000000e+00 9.321484440727880474e-21 1.529425652752814861e-19 1.999300110038510638e+03 1.494144560743164650e-19 1.504664363489135164e-19 2.161053363205730942e-20 1.392901865208387364e-29 2.607636604311510636e-21 5.386695053909881803e-26 1.773303128836140428e-24 1.257759770756936166e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.289871976661729709e-21 0.000000000000000000e+00 9.339090772456139411e-21 1.524988728245058171e-19 2.001600109912067637e+03 1.500074657457027446e-19 1.506348243985016937e-19 2.494104651507822080e-20 1.385439648979237439e-29 2.606333271049828548e-21 5.368724228376884946e-26 1.769324207796279936e-24 1.257568104321282621e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.295693896243438701e-21 0.000000000000000000e+00 9.357088280902447352e-21 1.531733097740895638e-19 2.003850100431666760e+03 1.484563840995925004e-19 1.507995562382573824e-19 2.490051243557286389e-20 1.378253964970613380e-29 2.605062444762583515e-21 5.351144147653230645e-26 1.765431801226676920e-24 1.257384773662793818e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.316246703024531042e-21 0.000000000000000000e+00 9.374694465948872458e-21 1.533307582101146930e-19 2.006100109665517039e+03 1.508521873544380140e-19 1.509642944607211775e-19 2.395800281778151633e-20 1.371068221195205998e-29 2.603824939683965560e-21 5.333563922287159202e-26 1.761539362282060324e-24 1.257234773219848353e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.232420611352369435e-21 0.000000000000000000e+00 9.392300797434387485e-21 1.533397791504426729e-19 2.008400109539929190e+03 1.483581415167781595e-19 1.511326979960811271e-19 2.265352383905645439e-20 1.363741876562890352e-29 2.602559939753038675e-21 5.315593101627531186e-26 1.757560441240720546e-24 1.257081440071410266e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.457407590346318587e-21 0.000000000000000000e+00 9.410298305887388033e-21 1.533192576395885501e-19 2.010650100092007506e+03 1.489242469328237604e-19 1.512974449371264062e-19 2.310279693799449054e-20 1.356641906376332078e-29 2.601314698309372654e-21 5.298013025471936325e-26 1.753668034614929634e-24 1.256915373787269220e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.345524491990081229e-21 0.000000000000000000e+00 9.427904491187962165e-21 1.535442765508146585e-19 2.012900109295043876e+03 1.526916665906389906e-19 1.514621982070476423e-19 2.384091748538969151e-20 1.349541877335639634e-29 2.600060594819156038e-21 5.280432805216501060e-26 1.749775595723619870e-24 1.256730947015845977e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.394858338294853858e-21 0.000000000000000000e+00 9.445510822432358286e-21 1.538227165526298595e-19 2.015200109170302539e+03 1.500048893145853412e-19 1.516306170758000036e-19 2.356092446171146765e-20 1.342334899147441756e-29 2.598778627675569235e-21 5.262461989578610165e-26 1.745796674680815867e-24 1.256542422653123107e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.508644726069930216e-21 0.000000000000000000e+00 9.463522430775631558e-21 1.539520436725822444e-19 2.017500109045845875e+03 1.511366775660942582e-19 1.517990410967104038e-19 2.397295299992846199e-20 1.335193947152897578e-29 2.597509940024784625e-21 5.244491175673885820e-26 1.741817753637519258e-24 1.256351439127913916e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.284759987255948710e-21 0.000000000000000000e+00 9.482023699267490293e-21 1.541718305488611463e-19 2.019800108921672518e+03 1.496255082209692428e-19 1.519674702526486831e-19 2.079025241627088427e-20 1.328052995157473946e-29 2.596244940093080222e-21 5.226520363520240538e-26 1.737838832593732247e-24 1.256159772692565812e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.391900634178525454e-21 0.000000000000000000e+00 9.500524967761628547e-21 1.538816597530610531e-19 2.022100108797781786e+03 1.496937236209704568e-19 1.521359045265599132e-19 2.413585988123585711e-20 1.321059672246682513e-29 2.594983547699560543e-21 5.208549553135825604e-26 1.733859911549456672e-24 1.255968652853349300e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.435008159504996041e-21 0.000000000000000000e+00 9.519026236258038797e-21 1.545382664100333621e-19 2.024350099414624765e+03 1.507335771947250620e-19 1.523006814434762260e-19 2.347730504316827800e-20 1.314281575513442929e-29 2.593766339660940657e-21 5.190969486641492538e-26 1.729967504811625353e-24 1.255784227605703021e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.397701623313147699e-21 0.000000000000000000e+00 9.537125228761915315e-21 1.545984113373109547e-19 2.026600108556199984e+03 1.491222412102084217e-19 1.524654645828358293e-19 2.159128344137291128e-20 1.307503422974447689e-29 2.592549121600744305e-21 5.173389277136435247e-26 1.726075066026641257e-24 1.255599800839700782e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.451109200942616408e-21 0.000000000000000000e+00 9.555224370279297889e-21 1.544895485040532126e-19 2.028900108433138485e+03 1.491839370225094965e-19 1.526339138891170542e-19 2.510991589121269783e-20 1.300580626048840761e-29 2.591286824807758687e-21 5.155418472091432487e-26 1.722096144980930843e-24 1.255411276477232006e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.403605647547098502e-21 0.000000000000000000e+00 9.573725638782379680e-21 1.551849862976926370e-19 2.031200108310355517e+03 1.513261555416968257e-19 1.528023682466237944e-19 2.520929254079030599e-20 1.293658721656454038e-29 2.590004857663080649e-21 5.137447668890003206e-26 1.718117223934738845e-24 1.255222752114805360e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.254678029009301796e-21 0.000000000000000000e+00 9.592226907287701869e-21 1.553608607558678888e-19 2.033500108187850401e+03 1.514157516402758077e-19 1.529708276386685651e-19 2.268996431470285040e-20 1.286762183550537857e-29 2.588722890518247257e-21 5.119476867551589551e-26 1.714138302888065996e-24 1.255034227752421783e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.395636444212366716e-21 0.000000000000000000e+00 9.610728175795259943e-21 1.551458885165937131e-19 2.035800108065622453e+03 1.544917753604227101e-19 1.531392920486367780e-19 2.493181792714128652e-20 1.280034683908054319e-29 2.587472072685810834e-21 5.101506068095908605e-26 1.710159381840913765e-24 1.254845703390080713e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.551349942592875926e-21 0.000000000000000000e+00 9.629229444305046378e-21 1.556639101151896745e-19 2.038100107943670082e+03 1.513654485658914585e-19 1.533077614599863800e-19 2.491508745707018033e-20 1.273307184264764754e-29 2.586227810456702908e-21 5.083535270542961564e-26 1.706180460793284725e-24 1.254657179027782337e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.352905564710329254e-21 0.000000000000000000e+00 9.647730712817050641e-21 1.558186060034366210e-19 2.040400107821992606e+03 1.493849207353914244e-19 1.534762358562473960e-19 2.445429365962897941e-20 1.266609688663995944e-29 2.584983548227446776e-21 5.065564474913028001e-26 1.702201539745180344e-24 1.254468654665527407e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.748008908993484465e-21 0.000000000000000000e+00 9.666848937872636987e-21 1.559317251103364746e-19 2.042750117284702583e+03 1.512778964451415619e-19 1.536483785732239237e-19 2.378412357511833768e-20 1.259824036340421122e-29 2.583712231632865781e-21 5.047202936915453964e-26 1.698136103828183006e-24 1.254276031161817040e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.594617673680538183e-21 0.000000000000000000e+00 9.686512880669751683e-21 1.559912314906144046e-19 2.045100107574198773e+03 1.533579494705222479e-19 1.538205250551534978e-19 2.363808086786012291e-20 1.253038439379501013e-29 2.582440925410679548e-21 5.028841550779138744e-26 1.694070701080189479e-24 1.254083409229748262e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.550499296892817288e-21 0.000000000000000000e+00 9.706176663033053161e-21 1.561376778026621222e-19 2.047400107453352803e+03 1.521326439593875218e-19 1.539890145222831740e-19 2.457913236017942646e-20 1.246528315176478995e-29 2.581196663180973154e-21 5.010870761129653225e-26 1.690091780030646587e-24 1.253894884867624235e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.596484571253024717e-21 0.000000000000000000e+00 9.725422145561834776e-21 1.564521511080274346e-19 2.049700107332777861e+03 1.522029578725058815e-19 1.541575089084562565e-19 2.560814655794850551e-20 1.240102469359500641e-29 2.579952400951120059e-21 4.992899973488185268e-26 1.686112858980634599e-24 1.253706360505543842e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.528034449836890675e-21 0.000000000000000000e+00 9.744667628092883872e-21 1.567806509417826417e-19 2.052000107212472813e+03 1.542977371568692254e-19 1.543260081975607522e-19 2.480948883381045734e-20 1.233676623541768248e-29 2.578708138721121015e-21 4.974929187876525715e-26 1.682133937930155719e-24 1.253517836143506896e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.570636519509167596e-21 0.000000000000000000e+00 9.763913110626191422e-21 1.568212266384663393e-19 2.054350116622448240e+03 1.522943976144946225e-19 1.544981762603644660e-19 2.323329379440365377e-20 1.227099673457144999e-29 2.577455583088051573e-21 4.956567660649913431e-26 1.678068502104387396e-24 1.253328055206768283e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.712709958042910111e-21 0.000000000000000000e+00 9.783577052982045475e-21 1.567574266007176832e-19 2.056700106967469765e+03 1.513775195427514105e-19 1.546703480110128893e-19 2.309222738974206466e-20 1.220519700491084807e-29 2.576204781775378930e-21 4.938206284553319825e-26 1.674003099260336878e-24 1.253138540075908813e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.658523154095796495e-21 0.000000000000000000e+00 9.803240835809961001e-21 1.569048476546760411e-19 2.059000106847981897e+03 1.531930277296552371e-19 1.548388621236641404e-19 2.150800290738706803e-20 1.214088325415630905e-29 2.574980588290590332e-21 4.920235505256709224e-26 1.670024178208444467e-24 1.252953056429516825e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.735567717113343007e-21 0.000000000000000000e+00 9.822486318350105602e-21 1.568508465943953707e-19 2.061300106728760966e+03 1.537257589170162036e-19 1.550073810748065851e-19 2.367523787651838464e-20 1.207846479585332020e-29 2.573756394805659546e-21 4.902264728081293676e-26 1.666045257156089939e-24 1.252767572783166967e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.811899005045808167e-21 0.000000000000000000e+00 9.841731800892484583e-21 1.573336714706521419e-19 2.063650116096880083e+03 1.518434920397308551e-19 1.551795691577512562e-19 2.467723301999570969e-20 1.201468915700159596e-29 2.572505583367789387e-21 4.885506556596024382e-26 1.662250851595638532e-24 1.252578056118385170e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.807718632204547960e-21 0.000000000000000000e+00 9.861894717303517445e-21 1.576580752473272986e-19 2.066000106485960259e+03 1.551638476435300846e-19 1.553517608679887253e-19 2.420036593779619323e-20 1.195113561099122080e-29 2.571254782031666289e-21 4.870258177846809310e-26 1.658711669356110563e-24 1.252388540984235632e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.826324036646521304e-21 0.000000000000000000e+00 9.882325742386660810e-21 1.577558837485265745e-19 2.068350115833068230e+03 1.551405625489136451e-19 1.555239589686272354e-19 2.487035729852253209e-20 1.188822766846863761e-29 2.570003970604979690e-21 4.855009677327478961e-26 1.655172458565012797e-24 1.252199024321281399e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.780792939256402073e-21 0.000000000000000000e+00 9.902756932292581528e-21 1.580285250978520764e-19 2.070700106244262315e+03 1.532549136823015480e-19 1.556961606663756342e-19 2.599494377565140886e-20 1.182532023284590348e-29 2.568753169257086226e-21 4.839761300932115562e-26 1.651633276292180685e-24 1.252009509185481655e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.658336459040751811e-21 0.000000000000000000e+00 9.923187957567985365e-21 1.583739793908586688e-19 2.073000106126384253e+03 1.517068558456585086e-19 1.558647039880889356e-19 2.309015436406274556e-20 1.176415719826345810e-29 2.567528975771440740e-21 4.824837299173129348e-26 1.648169381813485552e-24 1.251824025539347712e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.646316360716590926e-21 0.000000000000000000e+00 9.943184360745299205e-21 1.580900171361933648e-19 2.075350115442372044e+03 1.561439612616066925e-19 1.560369168858365033e-19 2.333404811369029830e-20 1.170211695232138088e-29 2.566278164361317890e-21 4.809588802627900313e-26 1.644630171069256032e-24 1.251634508879101442e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.929154904316909498e-21 0.000000000000000000e+00 9.963615550380658363e-21 1.583107537099413683e-19 2.077700105886313850e+03 1.553177421212970939e-19 1.562091333362567855e-19 2.438614066032413583e-20 1.164007720460131771e-29 2.565027362995994008e-21 4.794340429828069928e-26 1.641090988747104402e-24 1.251444993740859115e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.773546219719838344e-21 0.000000000000000000e+00 9.984046575940773326e-21 1.586323796816746876e-19 2.080050115181522870e+03 1.541102178623014119e-19 1.563813560875543126e-19 2.622170754692919444e-20 1.157874777805522393e-29 2.563776551596931338e-21 4.779091936010890071e-26 1.637551778034168561e-24 1.251255477082421978e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.833477022883692383e-21 0.000000000000000000e+00 1.000447776539548026e-20 1.590983909700057224e-19 2.082450115048777661e+03 1.557118724774832806e-19 1.565572475078910412e-19 2.456285791808757002e-20 1.151642162765636083e-29 2.562499132312747263e-21 4.763519069971101624e-26 1.633937279462375961e-24 1.251061928930992109e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.778862412062724739e-21 0.000000000000000000e+00 1.002534357732189254e-20 1.590052059243517829e-19 2.084800105525707295e+03 1.551776758114027678e-19 1.567294787739280622e-19 2.182740762173254205e-20 1.145539418265547932e-29 2.561287247986942213e-21 4.748270700931635768e-26 1.630398097090543348e-24 1.250874462054071303e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.905096758722109278e-21 0.000000000000000000e+00 1.004577460316880706e-20 1.587831800422256151e-19 2.087150114789702457e+03 1.539794192094141004e-19 1.569017162874209074e-19 2.628953392002811341e-20 1.139606983318083509e-29 2.560093592487769868e-21 4.733022211329728143e-26 1.626858886424616812e-24 1.250687953599236129e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.780975743872766261e-21 0.000000000000000000e+00 1.006650992699618591e-20 1.596223188514568746e-19 2.089500105288344002e+03 1.546926027862718981e-19 1.570739572800456025e-19 2.596792005617964386e-20 1.133682158788175135e-29 2.558899943959429486e-21 4.717773844844516806e-26 1.623319704020085252e-24 1.250501446499000208e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.689534963591158755e-21 0.000000000000000000e+00 1.008757567533404511e-20 1.597359095008003869e-19 2.091850114531790950e+03 1.590562240918080491e-19 1.572462044851318544e-19 2.218603786589880446e-20 1.127754479553439405e-29 2.557649132587917394e-21 4.702525358097273679e-26 1.619780493385105258e-24 1.250311929845069634e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.792784829700872718e-21 0.000000000000000000e+00 1.010864159170379703e-20 1.593411625507727651e-19 2.094250114400538223e+03 1.565304770220277342e-19 1.574221208003938486e-19 2.432895944946590563e-20 1.121684326039254066e-29 2.556371713302939249e-21 4.686952498992524229e-26 1.616165994811064709e-24 1.250118381693859441e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.595413588320048370e-21 0.000000000000000000e+00 1.013015563326062362e-20 1.598187428959390973e-19 2.096600104931791975e+03 1.542157381877324208e-19 1.575943763655359068e-19 2.359357832696510870e-20 1.115740657680206119e-29 2.555128516464299317e-21 4.671704136467442009e-26 1.612626812357417872e-24 1.249930018755822502e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.632404321152369876e-21 0.000000000000000000e+00 1.015122138189082393e-20 1.598813194246554389e-19 2.098950114144370673e+03 1.542955896467169656e-19 1.577666380908258478e-19 2.622943959490009126e-20 1.109873659913177231e-29 2.553897559257710539e-21 4.656455654133115452e-26 1.609087601768926659e-24 1.249743510305395901e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.740670286809005271e-21 0.000000000000000000e+00 1.017228729798386637e-20 1.604673588474678123e-19 2.101350114014003793e+03 1.568764098325455445e-19 1.579425691884519077e-19 2.629635731150796275e-20 1.103997296596014814e-29 2.552640416468855307e-21 4.640882799367572532e-26 1.605473103193552108e-24 1.249553034347193003e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.703676288160866038e-21 0.000000000000000000e+00 1.019380133954863441e-20 1.606508361082117600e-19 2.103750113883934318e+03 1.546083060142823418e-19 1.581185052499349229e-19 2.693717442502799546e-20 1.098120933278124283e-29 2.551411053265303418e-21 4.625309946098209498e-26 1.601858604617729583e-24 1.249362558389034115e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.789577761214937978e-21 0.000000000000000000e+00 1.021531538111606866e-20 1.609353095695437509e-19 2.106150113754161339e+03 1.553877141155725754e-19 1.582944462587237162e-19 2.318808724836598875e-20 1.092356744631903151e-29 2.550192005712172287e-21 4.609737094340215367e-26 1.598244106041460370e-24 1.249172082430919238e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.669047662997978582e-21 0.000000000000000000e+00 1.023682942268616010e-20 1.605194380378723465e-19 2.108500104339575046e+03 1.558365124807384573e-19 1.584667259268436635e-19 2.447884549192935229e-20 1.086772886405069585e-29 2.548996821199906668e-21 4.594488738738779950e-26 1.594704923506246348e-24 1.248985823604073996e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.841164834572088033e-21 0.000000000000000000e+00 1.025789517180186026e-20 1.608902816668458206e-19 2.110850113500877342e+03 1.572640847885482788e-19 1.586390116688888859e-19 2.366468773254308338e-20 1.081188984039706791e-29 2.547785097726110212e-21 4.579240264084497520e-26 1.591165712994979604e-24 1.248802229352514358e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.680461329744182819e-21 0.000000000000000000e+00 1.027922141786634425e-20 1.609318367085953519e-19 2.113250113371975203e+03 1.565552584609270712e-19 1.588149672172542013e-19 2.465684218749722405e-20 1.075475184514022999e-29 2.546547597792575358e-21 4.563667416888582615e-26 1.587551214417398980e-24 1.248614729581372705e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.824577148911922516e-21 0.000000000000000000e+00 1.030170160689855384e-20 1.612623535992411256e-19 2.115650113243365922e+03 1.583312131695522209e-19 1.589909276481230244e-19 2.555979434015898508e-20 1.069758821183983242e-29 2.545317402797020513e-21 4.548094571266215557e-26 1.583936715839377362e-24 1.248410970450834443e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.846062961590628131e-21 0.000000000000000000e+00 1.032418179593350487e-20 1.615784786659958658e-19 2.118050113115047679e+03 1.570282004864874012e-19 1.591668929453023530e-19 2.509064278362284133e-20 1.064047916511979239e-29 2.544098355243150231e-21 4.532521727233644916e-26 1.580322217260917505e-24 1.248182399301372728e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.826148139728617513e-21 0.000000000000000000e+00 1.034666198497118380e-20 1.616786088891646655e-19 2.120450112987020475e+03 1.621036680643933638e-19 1.593428630926703237e-19 2.426963862286851957e-20 1.058418825903170262e-29 2.542879307689132494e-21 4.516948884807333925e-26 1.576707718682019226e-24 1.247953828151981167e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.916888464116558560e-21 0.000000000000000000e+00 1.036914217401158762e-20 1.617324433632626328e-19 2.122850112859282490e+03 3.077703185009709398e-19 1.595188380741757308e-19 2.508423638783090233e-20 1.052789735293682916e-29 2.541646035556932566e-21 4.501376044003985741e-26 1.573093220102685462e-24 1.247756918123219929e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.864496651130136441e-21 0.000000000000000000e+00 1.039162236305469978e-20 1.620287986840027516e-19 2.125250112731832360e+03 7.248975897595519838e-19 1.596948178738376652e-19 2.402378662342897206e-20 1.047213773427891652e-29 2.540408535622649158e-21 4.485803204840530236e-26 1.569478721522918051e-24 1.247569418352331807e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.805186897413552378e-21 0.000000000000000000e+00 1.041410255210050974e-20 1.620400004980319840e-19 2.127650112604670539e+03 2.753308411322581123e-19 1.598708024757453453e-19 2.501708085083078027e-20 1.041754669239525243e-29 2.539174943697664736e-21 4.470230367334122281e-26 1.565864222942716443e-24 1.247381918581486754e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.892479163143669592e-21 0.000000000000000000e+00 1.043658274114901902e-20 1.623691617231817057e-19 2.130050112477794755e+03 1.594956076933057777e-19 1.600467918640572513e-19 2.331280736075936428e-20 1.036295565050508350e-29 2.537974943761102610e-21 4.454657531502175608e-26 1.562249724362084125e-24 1.247194418810685524e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.734043529668028450e-21 0.000000000000000000e+00 1.045906293020020805e-20 1.622826756400371420e-19 2.132500121922622384e+03 1.576384314101801181e-19 1.602264533206797420e-19 2.381251534947608648e-20 1.030769279277710853e-29 2.536749939038688925e-21 4.438760201212907572e-26 1.558559909308328607e-24 1.247003012046732090e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.853869344646318021e-21 0.000000000000000000e+00 1.048201154620376977e-20 1.625395280537225824e-19 2.134950112219642961e+03 1.596327775373745503e-19 1.604061183279092189e-19 2.647046917895932863e-20 1.025284226373933607e-29 2.535506973386746441e-21 4.422862996951961289e-26 1.554870123091958277e-24 1.246811606778768250e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.820600507022985569e-21 0.000000000000000000e+00 1.050507648987531948e-20 1.631266694846201338e-19 2.137350112093633470e+03 1.606507557211416209e-19 1.605821221782076591e-19 2.578242478241624872e-20 1.019911092327686375e-29 2.534269473451720120e-21 4.407290166322676848e-26 1.551255624510021344e-24 1.246624107008099804e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.883658945259090001e-21 0.000000000000000000e+00 1.052853068586902967e-20 1.631941482514700984e-19 2.139750111967906378e+03 1.582579400115974949e-19 1.607581307515856762e-19 2.597744963947407340e-20 1.014582140059144768e-29 2.533031973516548226e-21 4.391717337440725731e-26 1.547641125927659030e-24 1.246436607237475556e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.001201360988652702e-21 0.000000000000000000e+00 1.055198488186549786e-20 1.634054404182228588e-19 2.142150111842460774e+03 1.589960064977666610e-19 1.609341440325467324e-19 2.642580387442059184e-20 1.009266319441474962e-29 2.531824944078769507e-21 4.376144510324787849e-26 1.544026627344872803e-24 1.246249107466895319e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.083831011196903602e-21 0.000000000000000000e+00 1.057543907786471651e-20 1.636559602891880765e-19 2.144600121234725975e+03 1.585911256695089003e-19 1.611138297947697962e-19 2.383049123015427099e-20 1.003839740415057134e-29 2.530599939382636866e-21 4.360247189379433720e-26 1.540336812370278380e-24 1.246057700707388451e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.820618193535095267e-21 0.000000000000000000e+00 1.059938199598540417e-20 1.634228381507787340e-19 2.147050111587213905e+03 2.939299834266478344e-19 1.612935190339146090e-19 2.537123399223723672e-20 9.985938787191418938e-30 2.529374944206392868e-21 4.344349993859493850e-26 1.536647026070372095e-24 1.245859262450124886e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.052614514764344133e-21 0.000000000000000000e+00 1.062332472803830452e-20 1.638442807384705732e-19 2.149450111462619589e+03 1.398516851715853213e-18 1.614695465392155165e-19 2.355900311632137759e-20 9.934550554565087972e-30 2.528174944268690231e-21 4.328777172232773648e-26 1.533032527486303661e-24 1.245634262725601032e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.966490660143146496e-21 0.000000000000000000e+00 1.064677892404584228e-20 1.637443227654862761e-19 2.151900120823454927e+03 8.342118980106151375e-19 1.616492467718234691e-19 2.411785943839211219e-20 9.882051134540672536e-30 2.526949939588272351e-21 4.312879857161766570e-26 1.529342712559044008e-24 1.245404574617413118e-21 0.000000000000000000e+00 0.000000000000000000e+00 7.965326177211503171e-21 0.000000000000000000e+00 1.067072184185937872e-20 1.640042601959352601e-19 2.154350111209101215e+03 1.750129654849224880e-19 1.618289504377137649e-19 2.463388910356097144e-20 9.829394624759615824e-30 2.525735329866288476e-21 4.296982667159746415e-26 1.525652926209199784e-24 1.245197606479047926e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.098890036394551454e-21 0.000000000000000000e+00 1.069466457423632130e-20 1.642660507246727808e-19 2.156750111085349545e+03 1.621402792380826926e-19 1.620049920264793929e-19 2.661334033535132905e-20 9.777812537867113695e-30 2.524553791465674147e-21 4.281409851205346078e-26 1.522038427623862367e-24 1.245012991320622382e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.095997692387579382e-21 0.000000000000000000e+00 1.071811877025209543e-20 1.647490030483531160e-19 2.159200120414965113e+03 1.601175397077125941e-19 1.621847065863057281e-19 2.445202254893591778e-20 9.725891610182490115e-30 2.523347633026478569e-21 4.265512542196921268e-26 1.518348612743621018e-24 1.244824529285749784e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.303211936178338732e-21 0.000000000000000000e+00 1.074206168776053447e-20 1.646026504910340403e-19 2.161650110833542840e+03 1.619119663356627571e-19 1.623644245363774316e-19 2.490102154983725342e-20 9.674874162642696350e-30 2.522108405269124338e-21 4.251447480159904510e-26 1.514985919446254843e-24 1.244636068705637774e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.419320584912202089e-21 0.000000000000000000e+00 1.076676282616415024e-20 1.648544373748226025e-19 2.164100120142319156e+03 1.610548130165464600e-19 1.625441486337399670e-19 2.596129649742739454e-20 9.623856321742297507e-30 2.520864554389283983e-21 4.238225348100720287e-26 1.511773709626877397e-24 1.244447606672502275e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.118557228046829970e-21 0.000000000000000000e+00 1.079153378946277898e-20 1.651812966232056543e-19 2.166550110582874822e+03 1.611996357397332541e-19 1.627238760927905184e-19 2.502381492429364194e-20 9.573324200386864025e-30 2.519629176328430824e-21 4.225003319033138843e-26 1.508561524545644117e-24 1.244250682861043443e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.117061033915899396e-21 0.000000000000000000e+00 1.081630456199315367e-20 1.652150930800778771e-19 2.169000119870905110e+03 1.601619822676795412e-19 1.629036096645853648e-19 2.374168119842711075e-20 9.523026950885534889e-30 2.518423017909708408e-21 4.211781189425282210e-26 1.505349314753466692e-24 1.244024528423368334e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.090281755887862890e-21 0.000000000000000000e+00 1.084107552508202909e-20 1.652032841656055973e-19 2.171450110333338216e+03 1.879631620613714163e-19 1.630833465697754257e-19 2.550424375537596637e-20 9.472730087862641710e-30 2.517216868758972026e-21 4.198559162601049658e-26 1.502137129643549880e-24 1.243798375723535421e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.315368245170735721e-21 0.000000000000000000e+00 1.086584629783359684e-20 1.656554851496745585e-19 2.173900119600714334e+03 8.533193368236236432e-19 1.632630895534524711e-19 2.747102776446344275e-20 9.423597607985710551e-30 2.516010710350417542e-21 4.185337035488438646e-26 1.498924919878452172e-24 1.243593761564167754e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.236369034395846598e-21 0.000000000000000000e+00 1.089061726071364578e-20 1.661439554535512022e-19 2.176400119463330611e+03 7.962357640199837578e-19 1.634465048850762220e-19 2.574479290768601921e-20 9.373597610733386385e-30 2.514779941187283531e-21 4.171845122069212283e-26 1.495647167390585363e-24 1.243401454108710457e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.155536839409890463e-21 0.000000000000000000e+00 1.091589365644880192e-20 1.660454576434782693e-19 2.178850109958614667e+03 1.844096040844461620e-19 1.636262559379726835e-19 2.543834824383541567e-20 9.324612513178212699e-30 2.513573792020374227e-21 4.158623098719522922e-26 1.492434982237597520e-24 1.243212993523204902e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.463916305982053699e-21 0.000000000000000000e+00 1.094066442953251134e-20 1.661922406282320411e-19 2.181300119194972012e+03 1.606149460693229858e-19 1.638060130181608433e-19 2.643439690211929841e-20 9.275756446641441185e-30 2.512367633627090638e-21 4.145400975461005467e-26 1.489222772513168610e-24 1.243024531496147179e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.181678241492216601e-21 0.000000000000000000e+00 1.096543539209894365e-20 1.665119364370079206e-19 2.183800119058518703e+03 1.609900733990288611e-19 1.639894426884715767e-19 2.630679951879209969e-20 9.225903508186010265e-30 2.511136864463498466e-21 4.131909065835042551e-26 1.485945020024081858e-24 1.242832224040825675e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.055283746085805187e-21 0.000000000000000000e+00 1.099071178784350676e-20 1.666676897257826027e-19 2.186250109586427698e+03 1.647774325716378082e-19 1.641692077488741057e-19 2.532876876153708406e-20 9.177539907138155680e-30 2.509936310503550333e-21 4.118687046067687148e-26 1.482732834828319612e-24 1.242633272422208254e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.279093714051953842e-21 0.000000000000000000e+00 1.101640715239513231e-20 1.667058002562433627e-19 2.188700118791974091e+03 1.645428420119875428e-19 1.643489787860142126e-19 2.489701773888638840e-20 9.130102047738011157e-30 2.508748427252376323e-21 4.105464926770078264e-26 1.479520625144286933e-24 1.242410544575102214e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.372158202685830534e-21 0.000000000000000000e+00 1.104242685158605307e-20 1.668242007289793538e-19 2.191200118656440736e+03 1.616647494329371509e-19 1.645324226532156012e-19 2.669795545213351227e-20 9.081696253260801765e-30 2.507536306105967887e-21 4.091973021049001971e-26 1.476242872653994013e-24 1.242183272128092768e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.211072933468116221e-21 0.000000000000000000e+00 1.106897746384641101e-20 1.672766381478995133e-19 2.193700118521217064e+03 1.603637351306737283e-19 1.647158712849470569e-19 2.553037648159038530e-20 9.033696290233020634e-30 2.506324184959409740e-21 4.078481116673132025e-26 1.472965120163295181e-24 1.241980243872573563e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.074370999848661808e-21 0.000000000000000000e+00 1.109552807611005657e-20 1.672699876391443679e-19 2.196200118386300801e+03 1.952351930583519662e-19 1.648993246653070669e-19 2.745751936604446645e-20 8.986015133385913946e-30 2.505112063812702634e-21 4.064989213655894202e-26 1.469687367672193191e-24 1.241790850166833419e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.114756179292636001e-21 0.000000000000000000e+00 1.112207868837696719e-20 1.677589645298883055e-19 2.198650108968379300e+03 8.754251027177311033e-19 1.650791128884766048e-19 2.439153425778448911e-20 8.939287776776993705e-30 2.503924189591088667e-21 4.051767200144570243e-26 1.466475182405409229e-24 1.241605245038735876e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.103670874607766670e-21 0.000000000000000000e+00 1.114809818978208684e-20 1.674628951513498175e-19 2.201100118122753884e+03 1.126935574171034371e-18 1.652589070050801727e-19 2.546474230362778928e-20 8.893000673049560834e-30 2.502736306364725299e-21 4.038545087735442630e-26 1.463262972788467890e-24 1.241419638503713406e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.122201857840910760e-21 0.000000000000000000e+00 1.117411788842955230e-20 1.678022506779595459e-19 2.203600117988742568e+03 2.015610757488240896e-19 1.654423743488646027e-19 2.465285162779669672e-20 8.845899226299050855e-30 2.501524185217579216e-21 4.025053188820124487e-26 1.459985220296179569e-24 1.241230244798106422e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.128699855936665295e-21 0.000000000000000000e+00 1.120066850070607301e-20 1.678638476196874213e-19 2.206100117855035478e+03 1.656714598357818558e-19 1.656258463789942644e-19 2.681699402053029716e-20 8.798797820535863748e-30 2.500324187068089367e-21 4.011561291318345762e-26 1.456707467803492315e-24 1.241028728109062737e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.176863087756493100e-21 0.000000000000000000e+00 1.122721911298582566e-20 1.683798547080092722e-19 2.208600117721630795e+03 1.659943451389435924e-19 1.658093230799124829e-19 2.766742820812794906e-20 8.752565938944914119e-30 2.499149944706506907e-21 3.998069395244443125e-26 1.453429715310408514e-24 1.240801455662456908e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.261992448088265690e-21 0.000000000000000000e+00 1.125376972526878921e-20 1.687036199876129594e-19 2.211100117588527610e+03 1.658871055409604082e-19 1.659928044361309777e-19 2.548014581461514968e-20 8.706334057348387321e-30 2.497975702344782635e-21 3.984577500612943803e-26 1.450151962816929454e-24 1.240574183215921797e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.246401254641580703e-21 0.000000000000000000e+00 1.128101096178262288e-20 1.685404764627660079e-19 2.213600117455725012e+03 1.619278510022277190e-19 1.661762904322294295e-19 2.666971471993160781e-20 8.660363593370909265e-30 2.496775700627527501e-21 3.971085607438569600e-26 1.446874210323056236e-24 1.240372670094384036e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.226695207293230647e-21 0.000000000000000000e+00 1.130884621461508648e-20 1.689058143379135024e-19 2.216100117323222548e+03 1.640184227735748889e-19 1.663597810528553600e-19 2.499783453836398840e-20 8.615220738620668088e-30 2.495563579479649791e-21 3.957593715736244357e-26 1.443596457828789595e-24 1.240183276389040739e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.436301863853673018e-21 0.000000000000000000e+00 1.133668146745089188e-20 1.688429030596717137e-19 2.218600117191018398e+03 1.687224950720136191e-19 1.665432762827232893e-19 2.504739735210698165e-20 8.570077883865038919e-30 2.494352182834140413e-21 3.944101825521097400e-26 1.440318705334131918e-24 1.239992501602461700e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.320817154520442176e-21 0.000000000000000000e+00 1.136451672029001800e-20 1.690271652835562849e-19 2.221150126623592314e+03 1.650999379906216240e-19 1.667304468520822824e-19 2.645123326499045271e-20 8.524131057778920866e-30 2.493134267881269187e-21 3.930340047418262970e-26 1.436975385245723501e-24 1.239764142819072356e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.756125167021277167e-21 0.000000000000000000e+00 1.139290878471057861e-20 1.694489022771325328e-19 2.223700116922243978e+03 1.683984592230811211e-19 1.669176207805154916e-19 2.635290198129375761e-20 8.478305145165471887e-30 2.491916362066987833e-21 3.916578374157912034e-26 1.433632090243821041e-24 1.239535785749266202e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.348021716349908239e-21 0.000000000000000000e+00 1.142130063609210385e-20 1.695990838502284742e-19 2.226200116790941138e+03 1.643224597913083504e-19 1.671011299293033072e-19 2.689841362091485907e-20 8.433377611293234268e-30 2.490737259395236248e-21 3.903086488558856202e-26 1.430354337747981625e-24 1.239326832527777484e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.420304282020758609e-21 0.000000000000000000e+00 1.144913588894126587e-20 1.698706455539555093e-19 2.228700116659933428e+03 1.665241040052527479e-19 1.672846436262577903e-19 2.692099128383324986e-20 8.389323674403451799e-30 2.489580543037941143e-21 3.889594604510245276e-26 1.427076585251755214e-24 1.239140265594416056e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.409172510460636979e-21 0.000000000000000000e+00 1.147697114179371401e-20 1.700560504530335977e-19 2.231200116529219031e+03 1.669167858233981758e-19 1.674681618564270801e-19 2.373557418342506928e-20 8.345609390974799760e-30 2.488423826680510622e-21 3.876102722028299128e-26 1.423798832755144196e-24 1.238953698661099390e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.569707545725362579e-21 0.000000000000000000e+00 1.150480639464942720e-20 1.697718776370877251e-19 2.233750125909341932e+03 1.658445951106698267e-19 1.676553558042402395e-19 2.717058934471193796e-20 8.301020655528079456e-30 2.487216357774642642e-21 3.862340952187621892e-26 1.420455512735504402e-24 1.238735785892426505e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.429600690335412787e-21 0.000000000000000000e+00 1.153319845848599319e-20 1.704651072895667921e-19 2.236300116263467771e+03 1.671865583737045567e-19 1.678425530404722509e-19 2.636239923549492380e-20 8.257564219066633422e-30 2.485998451933866210e-21 3.848579286691928292e-26 1.417112217660869699e-24 1.238507428818101563e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.619146832742645358e-21 0.000000000000000000e+00 1.156199085371117681e-20 1.705338151809927398e-19 2.238800116133640131e+03 1.635058438338300961e-19 1.680260849604684009e-19 2.544297757012318045e-20 8.215029010007925868e-30 2.484804422145127231e-21 3.835087409074545683e-26 1.413834465163096043e-24 1.238286535302742208e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.571463110754108478e-21 0.000000000000000000e+00 1.159090229133542648e-20 1.705744322550213251e-19 2.241350125482406384e+03 1.659961726442033605e-19 1.682132928233756350e-19 2.556695701039424890e-20 8.171657870384302840e-30 2.483586507232283374e-21 3.821325644422796682e-26 1.410491145184568063e-24 1.238096236323452819e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.522984343047922568e-21 0.000000000000000000e+00 1.162039206735810422e-20 1.707769218407021132e-19 2.243900115869688307e+03 1.694034483136177526e-19 1.684005039328692708e-19 2.491079515723701672e-20 8.128380890668718764e-30 2.482368601375671058e-21 3.807563983822067614e-26 1.407147850066462476e-24 1.237905938759267352e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.570525583182745433e-21 0.000000000000000000e+00 1.164988162409926146e-20 1.708687966183571099e-19 2.246400115740737874e+03 1.644395228457031289e-19 1.685840494069219718e-19 2.689413390316333159e-20 8.085952321428620016e-30 2.481190991224434607e-21 3.794072111227789328e-26 1.403870097567538673e-24 1.237702952207840429e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.257817896744082385e-21 0.000000000000000000e+00 1.167879306173365537e-20 1.713363654801177785e-19 2.248950125058357116e+03 1.669819672347783462e-19 1.687712710470591965e-19 2.564303906062363636e-20 8.043116245515569986e-30 2.480011136167028587e-21 3.780310351927807818e-26 1.400526777629847550e-24 1.237474593435746551e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.460085278832338149e-21 0.000000000000000000e+00 1.170828283739613155e-20 1.713407310408064920e-19 2.251500115478566840e+03 1.656659594584175868e-19 1.689584958925290907e-19 2.587322478590064843e-20 8.001023445903093070e-30 2.478831289853200447e-21 3.766548696389625845e-26 1.397183482468570280e-24 1.237246236356056088e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.472319601461977834e-21 0.000000000000000000e+00 1.173777239451808577e-20 1.715623151512849198e-19 2.254050124775400946e+03 1.677650139103648127e-19 1.691457267015171963e-19 2.780107626575516863e-20 7.958930334693380249e-30 2.477635235399811359e-21 3.752786940775859162e-26 1.393840162558130422e-24 1.237050726341655932e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.564746921098534487e-21 0.000000000000000000e+00 1.176726216994019084e-20 1.720542618609626070e-19 2.256600115217581333e+03 1.670296817476529356e-19 1.693329606884742383e-19 2.427419607786317064e-20 7.917260102385156283e-30 2.476435239897608891e-21 3.739025288732517747e-26 1.390496867368047479e-24 1.236863227267400932e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.256526186808183754e-21 0.000000000000000000e+00 1.179675172731622638e-20 1.716912470419372885e-19 2.259150124493722160e+03 1.695720779321702147e-19 1.695202006055830202e-19 2.886425088507103202e-20 7.875885303989180981e-30 2.475240384421979867e-21 3.725263536883834789e-26 1.387153547484738581e-24 1.236670577924876901e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.461013449471667381e-21 0.000000000000000000e+00 1.182624150249902262e-20 1.725959104387631998e-19 2.261750124350609894e+03 1.695775868768626742e-19 1.697111158549034046e-19 2.725616640537427919e-20 7.833699390818270463e-30 2.474055090369574927e-21 3.711232000490828083e-26 1.383744684897662816e-24 1.236441166445779456e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.698849307416084855e-21 0.000000000000000000e+00 1.185661909586921954e-20 1.725359689593910391e-19 2.264300114825771288e+03 1.687212043316790485e-19 1.698983635293024758e-19 2.465424518971853855e-20 7.792679846459445991e-30 2.472892594711780691e-21 3.699455666940748659e-26 1.380771891956362956e-24 1.236216167554035234e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.446760091792198470e-21 0.000000000000000000e+00 1.188778871817378774e-20 1.723182997901610275e-19 2.266850124070843776e+03 1.685307442671743426e-19 1.700856170840038886e-19 2.836641571300340695e-20 7.751736036045608368e-30 2.471721584385132135e-21 3.688012811239955115e-26 1.377861327262048767e-24 1.236008179209927083e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.567690709991776518e-21 0.000000000000000000e+00 1.191895856991099276e-20 1.730805439743367410e-19 2.269450123928701942e+03 1.693272117567268298e-19 1.702765461942851513e-19 2.436084761765308142e-20 7.710031847885268701e-30 2.470518599376272343e-21 3.676345629902366114e-26 1.374893703593182794e-24 1.235814149600908840e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.704381171853824110e-21 0.000000000000000000e+00 1.195073947825193141e-20 1.726666447430450168e-19 2.272000114436616968e+03 1.678828212145133678e-19 1.704638074200837365e-19 2.755374832719543014e-20 7.669806645506889503e-30 2.469338753021863881e-21 3.664902860539599056e-26 1.371983160285343361e-24 1.235623852028556038e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.737378365805764596e-21 0.000000000000000000e+00 1.198190910095686132e-20 1.733339292103690185e-19 2.274550123650828937e+03 1.712353159127646168e-19 1.706510744769602049e-19 2.780463292324763765e-20 7.629581148043263257e-30 2.468156464393818544e-21 3.653460008368191714e-26 1.369072595626253044e-24 1.235405809842631527e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.550975102287739519e-21 0.000000000000000000e+00 1.201307895231684437e-20 1.735509668626928876e-19 2.277150123509647074e+03 1.657804226483368422e-19 1.708420173107234721e-19 2.856130038804599054e-20 7.588898106185412136e-30 2.466950667357845005e-21 3.641792830516482997e-26 1.366104971956291474e-24 1.235179723167961550e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.598800835590866965e-21 0.000000000000000000e+00 1.204485986066951765e-20 1.738659607281952677e-19 2.279750123368787172e+03 1.687457628295043698e-19 1.710329647476599883e-19 2.665032864887646760e-20 7.549031441678595940e-30 2.465749208464229124e-21 3.630125653864365691e-26 1.363137348285962194e-24 1.234952933011632884e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.223428671187902895e-21 0.000000000000000000e+00 1.207664076902612405e-20 1.737844554784727645e-19 2.282300113920165131e+03 1.711226508218080158e-19 1.712202438910582957e-19 2.657716041661149104e-20 7.509931586557466012e-30 2.464586712771689532e-21 3.618682888951420444e-26 1.360226804928514511e-24 1.234727934113809569e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.821540328149780635e-21 0.000000000000000000e+00 1.210781039226232023e-20 1.739388822626140389e-19 2.284850123093416187e+03 1.699575463474764810e-19 1.714075288006493046e-19 2.720993911614744684e-20 7.470772754675906776e-30 2.463424208589766225e-21 3.607240041652705805e-26 1.357316240316176911e-24 1.234502933572979745e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.875586672771345851e-21 0.000000000000000000e+00 1.213898024312162168e-20 1.742258449672341913e-19 2.287450122953503978e+03 1.707123020753207567e-19 1.715984897799820456e-19 2.730786568822702441e-20 7.430784024433428612e-30 2.462248495484657674e-21 3.595572868621978945e-26 1.354348616644765993e-24 1.234296392719112058e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.913158912387499100e-21 0.000000000000000000e+00 1.217076115148981374e-20 1.744331367862628308e-19 2.290050122813908729e+03 1.695152775052779294e-19 1.717894553018781776e-19 2.669514176148072137e-20 7.390795294186076731e-30 2.461080379605345241e-21 3.583905696837780618e-26 1.351380992972993243e-24 1.234107987157169415e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.959538743542227175e-21 0.000000000000000000e+00 1.220424423402787645e-20 1.745309267705547785e-19 2.292650122674630893e+03 1.695416777085472549e-19 1.719804253512057172e-19 2.683819194853288742e-20 7.351764840177715255e-30 2.459912263725890620e-21 3.572238526312336999e-26 1.348413369300858294e-24 1.233919581595272288e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.979216323609168780e-21 0.000000000000000000e+00 1.223775438210060445e-20 1.747441499359829891e-19 2.295250122535668197e+03 1.721355968276478361e-19 1.721713999128993904e-19 2.750806871819835861e-20 7.313053731135606880e-30 2.458744147846294187e-21 3.560571357058045879e-26 1.345445745628363717e-24 1.233697116327242868e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.993165276368096526e-21 0.000000000000000000e+00 1.227126453017739495e-20 1.750391761309485182e-19 2.297850122397020186e+03 1.700672483253553483e-19 1.723623789719603196e-19 2.587719092725010663e-20 7.274342622088812562e-30 2.457576031966556320e-21 3.548904189087459449e-26 1.342478121955509880e-24 1.233471029653099888e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.034769866217513515e-21 0.000000000000000000e+00 1.230477467825824045e-20 1.749828973760425279e-19 2.300450122258685496e+03 1.692761949935965196e-19 1.725533625134556385e-19 2.642986794821113975e-20 7.236710560203124626e-30 2.456398494024957571e-21 3.537237022413300369e-26 1.339510498282298435e-24 1.233244942979028943e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.027711882967876889e-21 0.000000000000000000e+00 1.233828482634312438e-20 1.752554948559505868e-19 2.303050122120662763e+03 1.687312587227274075e-19 1.727443505225181789e-19 2.489665386383722470e-20 7.199099603295616680e-30 2.455192696987518895e-21 3.525569857048461195e-26 1.336542874608730852e-24 1.233018856305029844e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.133598811289183927e-21 0.000000000000000000e+00 1.237179497443202868e-20 1.752269564241308509e-19 2.305650121982951987e+03 1.707712242701340182e-19 1.729353429843462545e-19 2.936186524482422288e-20 7.161473231247193504e-30 2.453986899949935399e-21 3.513902693005996342e-26 1.333575250934807315e-24 1.232792769631102779e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.976948709265462369e-21 0.000000000000000000e+00 1.240530512252495337e-20 1.760987535974575235e-19 2.308250121845550893e+03 1.718873904608875311e-19 1.731263398842029142e-19 2.676061671310695136e-20 7.123773233239511096e-30 2.452803568446201771e-21 3.502235530299146768e-26 1.330607627260530395e-24 1.232589148464336972e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.832233232522225010e-21 0.000000000000000000e+00 1.243881527062186984e-20 1.758667909552645528e-19 2.310850121708459028e+03 1.686624298659996170e-19 1.733173412074159662e-19 2.692654022866691065e-20 7.086073235227344534e-30 2.451635452565764625e-21 3.490568368941319879e-26 1.327640003585900276e-24 1.232400742902836691e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.819338876535894000e-21 0.000000000000000000e+00 1.247232541872277209e-20 1.760818227450261235e-19 2.313500131114469241e+03 1.743229690706026385e-19 1.735120208708924617e-19 2.624396013900492603e-20 7.048168023818951911e-30 2.450444868629731145e-21 3.478676797664276617e-26 1.324615299329773223e-24 1.232208713465813156e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.812530664372948902e-21 0.000000000000000000e+00 1.250648011577912579e-20 1.761725364300552546e-19 2.316150121429956016e+03 1.689579867013091628e-19 1.737067036964150752e-19 2.673777773581663833e-20 7.010995556927739219e-30 2.449254293270599472e-21 3.466785313485005143e-26 1.321590616863450854e-24 1.231979727174940787e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.825024878124473969e-21 0.000000000000000000e+00 1.254183616964259447e-20 1.764415569199014691e-19 2.318750121293797292e+03 1.693942257351836225e-19 1.738977183704677004e-19 2.701267892762198372e-20 6.974524325960978073e-30 2.448086177389743286e-21 3.455118156310287975e-26 1.318622993187755810e-24 1.231753640501335714e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.831686530222360430e-21 0.000000000000000000e+00 1.257680298167215302e-20 1.766742377434015467e-19 2.321350121157943704e+03 1.732754932211183974e-19 1.740887374092737753e-19 2.774341724730135513e-20 6.938324347783024734e-30 2.446923517772910652e-21 3.443451000540616590e-26 1.315655369511712526e-24 1.231528609877664476e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.953190562091789689e-21 0.000000000000000000e+00 1.261176979370581471e-20 1.769839149500157706e-19 2.324000130522084419e+03 1.729979963823035601e-19 1.742834350658847487e-19 2.705925487494688023e-20 6.901587231666444551e-30 2.445749942197362499e-21 3.431559435211175258e-26 1.312630665303375012e-24 1.231301466490424718e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.892797979936447028e-21 0.000000000000000000e+00 1.264740917223084952e-20 1.770690702105788708e-19 2.326650120881951807e+03 1.750223796204403565e-19 1.744781358304065735e-19 2.862262531525715501e-20 6.864850379006365941e-30 2.444576375037992787e-21 3.419667956652209746e-26 1.309605982786396735e-24 1.231074324732220955e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.885666104602999753e-21 0.000000000000000000e+00 1.268304829517169632e-20 1.775082556906416348e-19 2.329250120747018627e+03 1.731765131093570009e-19 1.746691680435543682e-19 2.778814629215195464e-20 6.829176428123033476e-30 2.443424946526320321e-21 3.408000805240572890e-26 1.306638359109302853e-24 1.230876469563457977e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.906877384682597332e-21 0.000000000000000000e+00 1.271801510721773511e-20 1.775670721064458973e-19 2.331900130079902738e+03 1.727581656696807906e-19 1.748638790810630720e-19 2.651128837426000567e-20 6.792874930412293721e-30 2.442251370964614414e-21 3.396109244543564236e-26 1.303613654936641592e-24 1.230687183409891126e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.003303455821681072e-21 0.000000000000000000e+00 1.275365448532240713e-20 1.775708843780177909e-19 2.334550120472893468e+03 1.743424453324925521e-19 1.750585931864123066e-19 2.973252468035008955e-20 6.756642218309104586e-30 2.441078519797331099e-21 3.384217770375293399e-26 1.300588972381856661e-24 1.230497182603346749e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.973141045150161138e-21 0.000000000000000000e+00 1.278929360870872152e-20 1.782725170990981179e-19 2.337150120338871147e+03 1.727035737229758960e-19 1.752496384431433112e-19 2.962455478177482165e-20 6.721738110519265470e-30 2.439964234140483810e-21 3.372550623459773203e-26 1.297621348703723018e-24 1.230274325739825133e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.995951883280872801e-21 0.000000000000000000e+00 1.282426042076701254e-20 1.784458064179772486e-19 2.339800129640706473e+03 1.755487771971649832e-19 1.754443627288761872e-19 2.540962442713695513e-20 6.686162643179557803e-30 2.438828515868268548e-21 3.360659067536918913e-26 1.294596644566500525e-24 1.230047182358481655e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.210557775205723834e-21 0.000000000000000000e+00 1.285989979845411586e-20 1.780001284451898125e-19 2.342450120066593627e+03 1.754048948491072804e-19 1.756390900429356503e-19 2.775880869068189498e-20 6.650833558044202696e-30 2.437679232541937155e-21 3.348767597905027138e-26 1.291571961974167916e-24 1.229820040595175683e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.962730709256836260e-21 0.000000000000000000e+00 1.289695586872400519e-20 1.785322328391293569e-19 2.345100129347714301e+03 1.754645864484411893e-19 1.758338231432249975e-19 2.596435403663421217e-20 6.616025328027320114e-30 2.436505657003155080e-21 3.336876045267555007e-26 1.288547257860589023e-24 1.229592897215809668e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.877976479420318966e-21 0.000000000000000000e+00 1.293490903690869871e-20 1.784524021694183149e-19 2.347800129198963077e+03 1.728274315423143204e-19 1.760322342580545012e-19 2.702829422460182148e-20 6.580560465116322862e-30 2.435309942783316169e-21 3.324760168481676785e-26 1.285465494821147321e-24 1.229361468935692006e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.972402738776878283e-21 0.000000000000000000e+00 1.297357816504464049e-20 1.788131314911682091e-19 2.350450119657934920e+03 1.725197438678639345e-19 1.762269748151570478e-19 2.783867545806504756e-20 6.545888850488301288e-30 2.434148539304281787e-21 3.312868703598391887e-26 1.282440812191052141e-24 1.229136681436224460e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.017012753984003747e-21 0.000000000000000000e+00 1.301153106366039690e-20 1.791339745026788155e-19 2.353100128907962244e+03 1.734956714387207513e-19 1.764217211099725106e-19 2.760532359945706931e-20 6.511329825748219441e-30 2.432991493012016617e-21 3.300977156050286259e-26 1.279416108112962891e-24 1.228912737262311336e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.843789902314122514e-21 0.000000000000000000e+00 1.304948423139977479e-20 1.792835990957799842e-19 2.355750119388726944e+03 1.737760128160482214e-19 1.766164703678220688e-19 3.012514623232309409e-20 6.476771045779892200e-30 2.431833518556420993e-21 3.289085694402035283e-26 1.276391425457993331e-24 1.228688613444197588e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.923292183925855644e-21 0.000000000000000000e+00 1.308743713032764771e-20 1.798867190382538000e-19 2.358400128618268809e+03 1.766320914369441427e-19 1.768112253315781953e-19 2.661215883672873299e-20 6.443278387984366736e-30 2.430659943040480748e-21 3.277194150314918501e-26 1.273366721403286133e-24 1.228461470069756237e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.925497156002405448e-21 0.000000000000000000e+00 1.312539029777363274e-20 1.795265272825182433e-19 2.361100128471189237e+03 1.752446890520632812e-19 1.770096586519034105e-19 2.721058333508409536e-20 6.409438389827763433e-30 2.429464228819901934e-21 3.265078282090187447e-26 1.270284958361936642e-24 1.228230041790008715e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.293741010212005926e-21 0.000000000000000000e+00 1.316405942593351625e-20 1.798330115165808066e-19 2.363800128324445723e+03 1.773706132712382892e-19 1.772080964352761230e-19 2.708447343711636384e-20 6.375598390742088037e-30 2.428276000309044517e-21 3.252962415661175542e-26 1.267203195320203461e-24 1.228000062355661197e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.107452836079402396e-21 0.000000000000000000e+00 1.320272855409821157e-20 1.800026121813466534e-19 2.366450118848905731e+03 1.776754747719126120e-19 1.774028630843777292e-19 2.619441199073489740e-20 6.342366077138047317e-30 2.427118962192731128e-21 3.241070960769925530e-26 1.264178512615360431e-24 1.227776119764688326e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.886710579663960364e-21 0.000000000000000000e+00 1.324068145365188382e-20 1.800544658224691632e-19 2.369100128037366630e+03 1.765605358021129196e-19 1.775976353759764660e-19 2.739302303730520317e-20 6.309133529477346560e-30 2.425961915927346975e-21 3.229185530736285283e-26 1.261154998488766212e-24 1.227552175596576126e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.032564391102897917e-21 0.000000000000000000e+00 1.327964250213546835e-20 1.804345479775906369e-19 2.371800127891612192e+03 1.773842672240095643e-19 1.777960862955225298e-19 2.856229487406391963e-20 6.275403829227695580e-30 2.424812622017628800e-21 3.219116945674707083e-26 1.258472135008409400e-24 1.227353586100711179e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.883093037764325205e-21 0.000000000000000000e+00 1.332069859218962676e-20 1.808064972782820500e-19 2.374500127746188809e+03 1.770527403771675496e-19 1.779945416191547327e-19 2.714197709164503066e-20 6.242128155344265885e-30 2.423671777008652719e-21 3.209048361706440222e-26 1.255789271527723634e-24 1.227163445495574620e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.860241350830759418e-21 0.000000000000000000e+00 1.336175468224881666e-20 1.807848562469285465e-19 2.377200127601096028e+03 1.734820098677156862e-19 1.781930013321583923e-19 2.800086853895218617e-20 6.208852481456761214e-30 2.422527722838416849e-21 3.198979778841819064e-26 1.253106408046709281e-24 1.226968138930048815e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.888705367233834153e-21 0.000000000000000000e+00 1.340281077231303504e-20 1.811154683492146538e-19 2.379900127456332484e+03 1.747478107103085424e-19 1.783914654198841390e-19 2.482416915067778993e-20 6.175998470524008985e-30 2.421365222900745859e-21 3.188911197091317447e-26 1.250423544565367809e-24 1.226743139214094222e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.137635524838201166e-21 0.000000000000000000e+00 1.344386686238225934e-20 1.808628103223829960e-19 2.382600127311896813e+03 1.921609390508987142e-19 1.785899338677471702e-19 2.929181808484302577e-20 6.143598472257237291e-30 2.420202722962933433e-21 3.178842616465537778e-26 1.247740681083700689e-24 1.226518139498212038e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.061645402261532032e-21 0.000000000000000000e+00 1.348492295245646999e-20 1.817242234253774083e-19 2.385300127167788560e+03 1.837753391009455013e-19 1.787884066612273944e-19 2.841524643854510906e-20 6.111198473986536355e-30 2.419050650492483607e-21 3.168774036975213332e-26 1.245057817601708103e-24 1.226291613813394554e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.885046586784328073e-21 0.000000000000000000e+00 1.352597904253565947e-20 1.817745096190746044e-19 2.388000127024005906e+03 1.961450797970621477e-19 1.789868837858685649e-19 2.513925957013112422e-20 6.079102496035769049e-30 2.417909805482814267e-21 3.158705458631221449e-26 1.242374954119391890e-24 1.226063445087578328e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.190699694653438236e-21 0.000000000000000000e+00 1.356703513261979919e-20 1.815052888023399069e-19 2.390700126880547941e+03 1.761373948002171373e-19 1.791853652272783035e-19 2.759859137938434073e-20 6.047134497734311732e-30 2.416768960473007629e-21 3.148636881444574927e-26 1.239692090636753150e-24 1.225835276361837522e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.205356048842218314e-21 0.000000000000000000e+00 1.360809122270887561e-20 1.820613619918893230e-19 2.393400126737413302e+03 1.791026012720814095e-19 1.793838509711275710e-19 2.686847986890928796e-20 6.015166499429025367e-30 2.415609667654724748e-21 3.138568305426427761e-26 1.237009227153793169e-24 1.225609807312171572e-21 0.000000000000000000e+00 0.000000000000000000e+00 8.967948298478481138e-21 0.000000000000000000e+00 1.364914731280286917e-20 1.821387982000152549e-19 2.396100126594601534e+03 1.796197397401503744e-19 1.795823410031503783e-19 2.881696928272005541e-20 5.983598521375053308e-30 2.414447167716213420e-21 3.128499730588074568e-26 1.234326363670512316e-24 1.225384807596657648e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.275880173625245093e-21 0.000000000000000000e+00 1.369072216999232164e-20 1.826500584996383362e-19 2.398800126452111272e+03 3.605153771447229849e-19 1.797808353091434978e-19 2.874629720746170038e-20 5.952062523039339866e-30 2.413291613978287153e-21 3.118431156940962070e-26 1.231643500186912058e-24 1.225159807881216698e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.083315535952022630e-21 0.000000000000000000e+00 1.373380010770725778e-20 1.828276435022999652e-19 2.401500126309941606e+03 2.550115040765876607e-19 1.799793338749659572e-19 2.889355977692396578e-20 5.920672254913817663e-30 2.412166614037524192e-21 3.108362584496679907e-26 1.228960636702993132e-24 1.224934808165849664e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.325507819343208228e-21 0.000000000000000000e+00 1.377687804542730966e-20 1.830614238390923137e-19 2.404200126168091629e+03 2.121374961609408535e-19 1.801778366865388718e-19 2.702695871428994926e-20 5.890119624940014862e-30 2.411041614096628447e-21 3.098294013266969246e-26 1.226277773218756638e-24 1.224709808450555792e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.090081926354341047e-21 0.000000000000000000e+00 1.381995598315245925e-20 1.829629556507918959e-19 2.406950135544980640e+03 2.019980135471415984e-19 1.803800205260273673e-19 2.623407179309249249e-20 5.859001097780480616e-30 2.409875636084800006e-21 3.088038952770404469e-26 1.223545217616469023e-24 1.224480641280524985e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.055083102682264484e-21 0.000000000000000000e+00 1.386383181237653240e-20 1.830483147839766587e-19 2.409700125880120140e+03 1.896473560037857584e-19 1.805822073406756612e-19 2.856383216412160108e-20 5.828040700706026491e-30 2.408691612468281426e-21 3.077783964568704105e-26 1.220812680935076600e-24 1.224251475697408355e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.483116045948640806e-21 0.000000000000000000e+00 1.390770733779344134e-20 1.836204795705440277e-19 2.412400125739232863e+03 1.975854867225208202e-19 1.807807229610745514e-19 2.953046634803157921e-20 5.797914386488559863e-30 2.407529112528941421e-21 3.067715397101272168e-26 1.218129817449883548e-24 1.224026475982339238e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.497371996306555347e-21 0.000000000000000000e+00 1.395078527553395021e-20 1.839723815153449981e-19 2.415150135084773410e+03 2.470829240185617149e-19 1.809829198008832740e-19 2.878201623577619775e-20 5.767230071685688138e-30 2.406379110381344203e-21 3.057460340595348279e-26 1.215397261878745432e-24 1.223797308815230992e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.487890206293523314e-21 0.000000000000000000e+00 1.399466110425786538e-20 1.840553738959914454e-19 2.417900125453214059e+03 1.815484131221808346e-19 1.811851195769366712e-19 2.854308562717670344e-20 5.736563934948176470e-30 2.405233281061160783e-21 3.047205356182156578e-26 1.212664725164263210e-24 1.223568143229650338e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.692430137996265823e-21 0.000000000000000000e+00 1.403853663020608422e-20 1.842309997626232932e-19 2.420600125313280387e+03 1.376084848858742930e-18 1.813836478785789579e-19 2.775048603236196739e-20 5.706467936507969896e-30 2.404112277268514882e-21 3.037136792591165793e-26 1.209981861678122599e-24 1.223343942743645097e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.533471999518263610e-21 0.000000000000000000e+00 1.408161456796181095e-20 1.843002237591908113e-19 2.423350134627681200e+03 2.522560205150551334e-18 1.815858575893498377e-19 2.819507361266507119e-20 5.675814499350115377e-30 2.402982136454377549e-21 3.026881740192897284e-26 1.207249306137926617e-24 1.223117914855663895e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.407915564717805798e-21 0.000000000000000000e+00 1.412570190388432224e-20 1.845635406142655094e-19 2.426100125029192895e+03 1.186027805175115348e-18 1.817880701979936694e-19 2.908065275157577618e-20 5.646185675012274907e-30 2.401852003412660398e-21 3.016626759688456184e-26 1.204516769390583267e-24 1.222891888522266638e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.431741871203474086e-21 0.000000000000000000e+00 1.417285724795844326e-20 1.849045127278766778e-19 2.428850134322824033e+03 1.820376082385048953e-19 1.819902884700972476e-19 2.981764653132471525e-20 5.616757004129779944e-30 2.400699258027293915e-21 3.006371710113284296e-26 1.201784213871025108e-24 1.222665860636195944e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.514595293016087229e-21 0.000000000000000000e+00 1.422001291598438096e-20 1.852283771542479518e-19 2.431600124746391430e+03 1.816476484362412766e-19 1.821925096146366488e-19 2.582665407223458401e-20 5.587324976407165719e-30 2.399531453874819778e-21 2.996116732300365953e-26 1.199051677101766136e-24 1.222439834301188917e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.507440400925655436e-21 0.000000000000000000e+00 1.426716826043670046e-20 1.848305230344283658e-19 2.434350134019344750e+03 1.816487851079450138e-19 1.823947363911502844e-19 2.632602920687179614e-20 5.557798561055455670e-30 2.398363641717812157e-21 2.985861685604623152e-26 1.196319121602754516e-24 1.222213806417021019e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.343129183075151529e-21 0.000000000000000000e+00 1.431432392810806542e-20 1.850954876965596964e-19 2.437100124464866440e+03 1.820059612411314886e-19 1.825969660149002497e-19 3.120034872509123090e-20 5.528272347850907235e-30 2.397231455699370054e-21 2.975606710541060397e-26 1.193586584811680572e-24 1.221987780080413439e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.351221807510039369e-21 0.000000000000000000e+00 1.436147927293684404e-20 1.860538931837401288e-19 2.439850133717232893e+03 1.840500633198311956e-19 1.827992012394024528e-19 2.903170318824201062e-20 5.499006402937839253e-30 2.396101314910726090e-21 2.965351666782655851e-26 1.190854029333125126e-24 1.221761752198141379e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.299066897134497073e-21 0.000000000000000000e+00 1.440863494025519808e-20 1.859024022827088875e-19 2.442600124184608831e+03 1.813530239334466116e-19 1.830014392861766725e-19 2.835793170221486441e-20 5.470435073406661572e-30 2.394971181841941724e-21 2.955096694527874858e-26 1.188121492520335577e-24 1.221535725859941145e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.506016458779421655e-21 0.000000000000000000e+00 1.445579028545872354e-20 1.860114548376936348e-19 2.445350133416481185e+03 1.817009544839497521e-19 1.832036829027417597e-19 3.197609306235000340e-20 5.441863548919677396e-30 2.393841041061719942e-21 2.944841653766334615e-26 1.185388937062144285e-24 1.221309697979557399e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.651226256661006691e-21 0.000000000000000000e+00 1.450294595242565555e-20 1.868067548027397399e-19 2.448150133263889984e+03 2.119101841696912235e-19 1.834096072639172906e-19 3.036427391569818949e-20 5.412983051792919717e-30 2.392690356192921862e-21 2.934400194863683701e-26 1.182606708269129593e-24 1.221079561286574483e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.458202113295010035e-21 0.000000000000000000e+00 1.455095883135769003e-20 1.867337065478398548e-19 2.450950133111647119e+03 1.794584280329989945e-19 1.836155359397358369e-19 2.711524627426433702e-20 5.384328507896391881e-30 2.391549946035818698e-21 2.923958737513823516e-26 1.179824479475768498e-24 1.220851479533527689e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.609336710967097174e-21 0.000000000000000000e+00 1.459897171029570091e-20 1.864472604702077117e-19 2.453700123622824776e+03 1.821731827549833099e-19 1.838177908165875263e-19 2.827082573043093645e-20 5.356185747859923494e-30 2.390435085017773838e-21 2.913703771115464433e-26 1.177091942619455353e-24 1.220628507602156551e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.459740578785692417e-21 0.000000000000000000e+00 1.464909004300045659e-20 1.868140959732766709e-19 2.456450132813609343e+03 1.857089442506289479e-19 1.840200512015266582e-19 3.049557892246141570e-20 5.328346713462845794e-30 2.389320216426915261e-21 2.903448736590400413e-26 1.174359387202090999e-24 1.220405534156324006e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.515727286955538888e-21 0.000000000000000000e+00 1.469958506792090724e-20 1.873691134822965030e-19 2.459250132662393753e+03 2.536613926745064157e-19 1.842259925822277300e-19 2.929752051097786811e-20 5.300128533168602168e-30 2.388185081353083541e-21 2.893007283942573881e-26 1.171577158407709245e-24 1.220141343509471219e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.545734021857162170e-21 0.000000000000000000e+00 1.475099800959958229e-20 1.873858751495101548e-19 2.462050132511521952e+03 1.841852610554834794e-19 1.844319382204654185e-19 2.927495658470997964e-20 5.271910352870893831e-30 2.387049946279112642e-21 2.882565832915221987e-26 1.168794929612986046e-24 1.219876478982652512e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.541155814743087287e-21 0.000000000000000000e+00 1.480241095128456777e-20 1.875886298539521106e-19 2.464850132360992120e+03 1.850588206118101645e-19 1.846378881019930181e-19 2.742193765413122063e-20 5.243967510996856683e-30 2.385909534646167481e-21 2.872124383526036265e-26 1.166012700817922872e-24 1.219623398756260385e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.345684621650695671e-21 0.000000000000000000e+00 1.485382389297583358e-20 1.875053874950391104e-19 2.467650132210804259e+03 1.861862959279952248e-19 1.848438422126272824e-19 2.809771461500878320e-20 5.216040239767562961e-30 2.384758849776381610e-21 2.861682935792965389e-26 1.163230472022520090e-24 1.219393262063856753e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.407858564983933010e-21 0.000000000000000000e+00 1.490523683467337973e-20 1.878152694922397491e-19 2.470450132060957458e+03 1.840872721181075652e-19 1.850498005382476543e-19 2.607423914357285849e-20 5.188267950793797447e-30 2.383608164906455808e-21 2.851241489734218041e-26 1.160448243226778251e-24 1.219163125371531549e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.505574155734312505e-21 0.000000000000000000e+00 1.495664977637718816e-20 1.877352387983735891e-19 2.473250131911449444e+03 1.831547768132788961e-19 1.852557630647960006e-19 2.789850503091253098e-20 5.161129490704412811e-30 2.382479947235420040e-21 2.840800045368281857e-26 1.157666014430699744e-24 1.218937482113587949e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.486183698982883551e-21 0.000000000000000000e+00 1.500806271808721675e-20 1.882031242568142123e-19 2.476050131762279307e+03 1.877321592949254250e-19 1.854617297782764442e-19 3.175686996180736375e-20 5.133991030611753340e-30 2.381359947295088213e-21 2.830358602713906773e-26 1.154883785634285670e-24 1.218713482399874104e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.448769972965667541e-21 0.000000000000000000e+00 1.505947565980344743e-20 1.890179229659376050e-19 2.478850131613446592e+03 1.872323407596611113e-19 1.856677006647549540e-19 2.998933347559103744e-20 5.107029513840970395e-30 2.380239135832386694e-21 2.819917161790121678e-26 1.152101556837536212e-24 1.218489320381986193e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.453983072968551662e-21 0.000000000000000000e+00 1.511088860152587719e-20 1.889357620955194352e-19 2.481650131464949482e+03 1.850226006716980407e-19 1.858736757103590807e-19 2.848937250560799339e-20 5.080321822949712369e-30 2.379104000757452830e-21 2.809804754225133449e-26 1.149386733285705798e-24 1.218262293645264813e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.332984154447984370e-21 0.000000000000000000e+00 1.516434755386071966e-20 1.889044043901277226e-19 2.484450131316787520e+03 1.829707108578855178e-19 1.860796549012777400e-19 2.864427308966291173e-20 5.053614132055257980e-30 2.377968865682383549e-21 2.801121244401054093e-26 1.146964632711856323e-24 1.218035266908620169e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.495067102100518969e-21 0.000000000000000000e+00 1.521865788407615795e-20 1.891428945089760465e-19 2.487250131168958433e+03 1.853135469663289416e-19 1.862856382237597198e-19 3.130053420956829748e-20 5.027175692106698917e-30 2.376839947532416437e-21 2.792437735631348973e-26 1.144542532137718669e-24 1.217809483555574306e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.476089477570158275e-21 0.000000000000000000e+00 1.527296821429805112e-20 1.897689508573119890e-19 2.490050131021462221e+03 1.878401071304222887e-19 1.864916256641149804e-19 2.807254132195941353e-20 5.000898770413971774e-30 2.375719947591415048e-21 2.783754227925894998e-26 1.142120431563293386e-24 1.217585483842235114e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.394763019258959697e-21 0.000000000000000000e+00 1.532727854452640217e-20 1.894663759612034729e-19 2.492850130874297520e+03 1.837486476280755145e-19 1.866976172087134749e-19 3.072533245756249879e-20 4.974621848718132347e-30 2.374599947650281252e-21 2.775070721294695923e-26 1.139698330988581209e-24 1.217361484128970589e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.403299159858252332e-21 0.000000000000000000e+00 1.538158887476118402e-20 1.900846714825662065e-19 2.495700140241211102e+03 1.867913177168579163e-19 1.869072920746904820e-19 3.049056498289074296e-20 4.948121775196964579e-30 2.373448591794103785e-21 2.766232123646096233e-26 1.137232970385598759e-24 1.217102833001828755e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.605170836582030420e-21 0.000000000000000000e+00 1.543686921691282941e-20 1.902673940025132064e-19 2.498550130575730691e+03 1.849985920849189613e-19 1.871169697642434324e-19 2.816981728814694072e-20 4.921668018758602295e-30 2.372293190307136075e-21 2.757393586157080739e-26 1.134767626246321660e-24 1.216833239652740330e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.330832521494541233e-21 0.000000000000000000e+00 1.549214918990174157e-20 1.901064926857288560e-19 2.501350130429564615e+03 1.850970023522551470e-19 1.873229736852725560e-19 2.995891135956455607e-20 4.895745659925947861e-30 2.371161790619908644e-21 2.748710082849596532e-26 1.132345525670745679e-24 1.216573853690526110e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.567935168097856542e-21 0.000000000000000000e+00 1.554645952015589406e-20 1.905984603521184454e-19 2.504150130283725957e+03 1.882434499378903438e-19 1.875289816561425444e-19 3.036160255182341403e-20 4.870510218202368048e-30 2.370056527519581779e-21 2.740026580658034712e-26 1.129923425094886476e-24 1.216352801342255908e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.433428602520357054e-21 0.000000000000000000e+00 1.560076985041639611e-20 1.908622963002061795e-19 2.507000139609091093e+03 1.891003003099696683e-19 1.877386731829947107e-19 2.831289143469304835e-20 4.844824058206672219e-30 2.368931523838516917e-21 2.731187987704726227e-26 1.127458064527844950e-24 1.216127800882794178e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.490547739543471199e-21 0.000000000000000000e+00 1.565605019176214514e-20 1.907608514307172200e-19 2.509850129987844412e+03 1.863412725556101648e-19 1.879483674837573723e-19 2.898811927949559402e-20 4.819267202639353575e-30 2.367816616404700123e-21 2.722349454689203717e-26 1.124992720350304224e-24 1.215901485994534274e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.347924739645637311e-21 0.000000000000000000e+00 1.571375765290362109e-20 1.910661946784489436e-19 2.512700139292390759e+03 1.873447528245714279e-19 1.881580673310406604e-19 2.915403296951454951e-20 4.794013955637044028e-30 2.366714612806942223e-21 2.713510864171195233e-26 1.122527359801271639e-24 1.215673485530820719e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.388900495269456744e-21 0.000000000000000000e+00 1.577385891404590208e-20 1.913046293716724736e-19 2.515550129693304370e+03 1.864945152135445288e-19 1.883677699275333329e-19 3.102452913951998628e-20 4.768760876135278514e-30 2.365612616518589129e-21 2.704672333480871148e-26 1.120062015604561355e-24 1.215445486579501017e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.615677422944466470e-21 0.000000000000000000e+00 1.583395977654662144e-20 1.918207160927776842e-19 2.518400138977124698e+03 1.898214398178787160e-19 1.885774780397610270e-19 3.033494814368652964e-20 4.743659542124428024e-30 2.364479944409150185e-21 2.695833745444586081e-26 1.117596655073457814e-24 1.215217486117656028e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.683005261552714644e-21 0.000000000000000000e+00 1.589406103725183068e-20 1.919247862837514589e-19 2.521250129400095830e+03 1.905998753383101629e-19 1.887871888767289489e-19 2.912369136869336578e-20 4.718695069052326476e-30 2.363339948239961619e-21 2.686995217127103528e-26 1.115131310857666869e-24 1.214989487164782793e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.065268100828643139e-20 0.000000000000000000e+00 1.595416190021770124e-20 1.919996576922167435e-19 2.524100138663282451e+03 1.899276089737123457e-19 1.889969051989043378e-19 2.990671669195814023e-20 4.693730430949477145e-30 2.362202576843441145e-21 2.678156631620201632e-26 1.112665950344412108e-24 1.214755432402129726e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.576669555894549194e-21 0.000000000000000000e+00 1.601426316048778573e-20 1.922744567939958554e-19 2.526950129108210604e+03 1.911280615679086587e-19 1.892066242215803207e-19 2.976272939837488246e-20 4.669092559574896809e-30 2.361077580615180114e-21 2.669318105724453255e-26 1.110200606109627746e-24 1.214492933605936218e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.667964452865548654e-21 0.000000000000000000e+00 1.607436402391668897e-20 1.924678443472134109e-19 2.529800138350854013e+03 1.866644638432999746e-19 1.894163486991914019e-19 3.114201798182751016e-20 4.644560834448344924e-30 2.359952576966768040e-21 2.660479522795879980e-26 1.107735245614143520e-24 1.214230433078516007e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.752442948840747768e-21 0.000000000000000000e+00 1.613446528375355659e-20 1.929011489984315793e-19 2.532700138192439226e+03 1.905975819674247566e-19 1.896297560153821366e-19 2.706076480661380004e-20 4.619598839183509118e-30 2.358827578847621842e-21 2.651485907976820794e-26 1.105226641452662434e-24 1.213983066795707174e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.547874855498114508e-21 0.000000000000000000e+00 1.619562074998787864e-20 1.924895509573476596e-19 2.535550128670305185e+03 1.901275836747112400e-19 1.898394872858389393e-19 2.870769159465317851e-20 4.595658919169434660e-30 2.357740082481067806e-21 2.642647385830332886e-26 1.102761297189385742e-24 1.213758067825285704e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.919177583646730273e-21 0.000000000000000000e+00 1.625572161411137754e-20 1.929581125709304149e-19 2.538400137882126728e+03 1.879769218368990929e-19 1.900492239660339831e-19 2.942267222588418441e-20 4.571718841790133307e-30 2.356652578966030943e-21 2.633808806887423588e-26 1.100295936720563565e-24 1.213533067375972346e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.835234203096374419e-21 0.000000000000000000e+00 1.631740433689911739e-20 1.932729085056208392e-19 2.541300137724782871e+03 1.878475454204474710e-19 1.902626436597594102e-19 2.975279534822808985e-20 4.547418856884300167e-30 2.355513103529691215e-21 2.624815196063558607e-26 1.097787332558156043e-24 1.213304120302889865e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.894341312700485556e-21 0.000000000000000000e+00 1.638360097173573262e-20 1.935418386921093298e-19 2.544200137567797810e+03 1.890767632806895308e-19 1.904760674994977361e-19 2.919648666618949910e-20 4.523348858187276142e-30 2.354368366749553675e-21 2.615821586614522088e-26 1.095278728395438300e-24 1.213075173229885812e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.754376543846749948e-21 0.000000000000000000e+00 1.644979760658053907e-20 1.936654988111237997e-19 2.547050128089355439e+03 1.888691891961432060e-19 1.906858149575288031e-19 3.330012795953004962e-20 4.499693936858348483e-30 2.353255146563749346e-21 2.606983069668230629e-26 1.092813384094366710e-24 1.212842397614263120e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.786708877610620034e-21 0.000000000000000000e+00 1.651485270729756935e-20 1.945392180934168963e-19 2.549900137260281099e+03 1.892441066218448528e-19 1.908955677657427963e-19 2.936582847112788887e-20 4.476218881328707765e-30 2.352181766486387608e-21 2.598144496242057516e-26 1.090348023660920851e-24 1.212583306191991627e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.570836799542725760e-21 0.000000000000000000e+00 1.657990823371303646e-20 1.941055565073019965e-19 2.552800137104352416e+03 1.908253356624498516e-19 1.911090038189386204e-19 2.914224345687219335e-20 4.452583882599526678e-30 2.351089558752906409e-21 2.589150890954625140e-26 1.087839419497289345e-24 1.212319670168833262e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.693858839687208308e-21 0.000000000000000000e+00 1.664610486858195314e-20 1.942935478680296485e-19 2.555700136948777526e+03 1.919771867326610819e-19 1.913224439633067530e-19 2.904977211892596406e-20 4.428948883867461719e-30 2.349968366993903877e-21 2.580157287099683010e-26 1.085330815333351660e-24 1.212075174516203638e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.666119764107202066e-21 0.000000000000000000e+00 1.671230150345894970e-20 1.944939412830741970e-19 2.558600136793555521e+03 1.900722460470316509e-19 1.915358881851701785e-19 3.096485339882237664e-20 4.405598905651554503e-30 2.348823630213070069e-21 2.571163684692278948e-26 1.082822211169108897e-24 1.211846227443634800e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.729892868549370754e-21 0.000000000000000000e+00 1.677849813834399906e-20 1.950076741279748124e-19 2.561500136638684580e+03 1.894443476253239253e-19 1.917493364709122593e-19 3.107631044718679331e-20 4.382398906890521837e-30 2.347678893432098210e-21 2.562170083747672568e-26 1.080313607004562343e-24 1.211617280371145331e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.710139025435599369e-21 0.000000000000000000e+00 1.684469477323706209e-20 1.952397379216904010e-19 2.564400136484164705e+03 1.927342064686352427e-19 1.919627888069770243e-19 2.764519797285980973e-20 4.359198908126680969e-30 2.346583065479989913e-21 2.553176484281333560e-26 1.077805002839711996e-24 1.211356035055478891e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.735970744054500616e-21 0.000000000000000000e+00 1.691089140813813879e-20 1.949402741065754913e-19 2.567300136329992711e+03 1.915579081433834813e-19 1.921762451798680141e-19 2.825825236615108244e-20 4.336384114742278936e-30 2.345490857745846675e-21 2.544182886308960055e-26 1.075296398674560980e-24 1.211092399032822509e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.940918380010482229e-21 0.000000000000000000e+00 1.697768103206615707e-20 1.952543715848792851e-19 2.570200136176169508e+03 1.923628563329410864e-19 1.923897055761488580e-19 2.832157255508271187e-20 4.313613745579706815e-30 2.344388258632661016e-21 2.535189289846461116e-26 1.072787794509108009e-24 1.210839154376292404e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.684043224428742760e-21 0.000000000000000000e+00 1.704820473768323357e-20 1.954668630498201180e-19 2.573100136022692823e+03 1.915177606044807127e-19 1.926031699824421669e-19 2.734031008204164452e-20 4.290858939022997372e-30 2.343258388562587261e-21 2.526195694909980851e-26 1.070279190343355471e-24 1.210613180642763432e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.961698631516407855e-21 0.000000000000000000e+00 1.711872844330873299e-20 1.955574503594876071e-19 2.576000135869561745e+03 1.906295938149166155e-19 1.928166383854297261e-19 3.014761145302231258e-20 4.268238940217419910e-30 2.342128518492378465e-21 2.517202101515889797e-26 1.067770586177303732e-24 1.210387206909312325e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.729552023083593105e-21 0.000000000000000000e+00 1.718925214894264031e-20 1.961739526311236431e-19 2.578950145246446482e+03 1.900638320909508630e-19 1.930337920667833125e-19 2.712806544783728154e-20 4.245228867077718654e-30 2.341012125485295639e-21 2.508053418204430965e-26 1.065218721969195560e-24 1.210135464847583552e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.011478057238818701e-20 0.000000000000000000e+00 1.726099201235584072e-20 1.959723761468761989e-19 2.581900135559081264e+03 1.904457207727050940e-19 1.932509484528387887e-19 2.990274098054277585e-20 4.222589232168809426e-30 2.339915334215213255e-21 2.498904795647812203e-26 1.062666874252349082e-24 1.209870722456218480e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.982465608351453878e-21 0.000000000000000000e+00 1.733273141215469209e-20 1.965886954683947087e-19 2.584800135406991103e+03 1.929867937237583221e-19 1.934644289028021042e-19 2.903948652018913737e-20 4.200945330864896668e-30 2.338837129143554574e-21 2.489911207036729029e-26 1.060158270085396988e-24 1.209610466383175894e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.836258686817727178e-21 0.000000000000000000e+00 1.740325511781391034e-20 1.966680849030033154e-19 2.587700135255242458e+03 1.942694497397238051e-19 1.936779132963197722e-19 2.931093839531182851e-20 4.179301429558434949e-30 2.337745403605168221e-21 2.480917620036514212e-26 1.057649665918149552e-24 1.209383312101084165e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.930309560630361538e-21 0.000000000000000000e+00 1.747377882348143416e-20 1.969292686866513635e-19 2.590650144590478703e+03 1.918917680641428391e-19 1.938950831865041599e-19 3.042586197529390584e-20 4.157213729493691057e-30 2.336634361128261221e-21 2.471768943433983905e-26 1.055097801746068629e-24 1.209153441529804126e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.019836592362137446e-20 0.000000000000000000e+00 1.754551868588180607e-20 1.973317262064220878e-19 2.593600134947559582e+03 1.932049060208412738e-19 1.941122557331222033e-19 2.786676772860934793e-20 4.135070591998564645e-30 2.335515332712477173e-21 2.462620327392184998e-26 1.052545953990774852e-24 1.208911749345061551e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.014051733638655044e-20 0.000000000000000000e+00 1.761725808676151941e-20 1.971705823503646207e-19 2.596500134796838665e+03 1.930473426791655231e-19 1.943257520137873719e-19 2.903941149425568710e-20 4.113302691895333835e-30 2.334399948155061937e-21 2.453626745388917746e-26 1.050037349822638264e-24 1.208651493272409605e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.019203157271355291e-20 0.000000000000000000e+00 1.768778179245403819e-20 1.975586766270382583e-19 2.599450144100992020e+03 1.907113141270706734e-19 1.945429339535461493e-19 2.960820348955354278e-20 4.091718464826936234e-30 2.333265329191926181e-21 2.444998854609642764e-26 1.047596563485889959e-24 1.208386749177488028e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.994371876993519742e-21 0.000000000000000000e+00 1.776655350522733923e-20 1.978535849676028021e-19 2.602400134491235349e+03 1.921234490493569053e-19 1.947601185140295300e-19 2.977924552058421363e-20 4.070277071258826518e-30 2.332156360253258475e-21 2.437398869247726981e-26 1.045375023694591390e-24 1.208147649498033430e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.974795216693996056e-21 0.000000000000000000e+00 1.784571689493084559e-20 1.980988943775510607e-19 2.605350143774664957e+03 1.902969527862496074e-19 1.949773084652648771e-19 3.285927413254970014e-20 4.048834755221577964e-30 2.331059561929932005e-21 2.429798836264569768e-26 1.043153469675461846e-24 1.207920725989921954e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.984067653228002336e-21 0.000000000000000000e+00 1.792488079163555124e-20 1.988058313617233523e-19 2.608300134187015374e+03 1.918705757906494856e-19 1.951945010135642726e-19 3.046740786801050783e-20 4.027347170736555986e-30 2.329962770622776221e-21 2.422198852961185949e-26 1.040931929867515153e-24 1.207692520163509249e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.012169076913420429e-20 0.000000000000000000e+00 1.800404418193230120e-20 1.986520517082088114e-19 2.611250143449812640e+03 1.935414834930589387e-19 1.954116989228762668e-19 2.874180589190220624e-20 4.005859448945809849e-30 2.328865972307120745e-21 2.414598822166626738e-26 1.038710375863923073e-24 1.207427776072823213e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.013103904670302001e-20 0.000000000000000000e+00 1.808320807808333509e-20 1.986160752508331228e-19 2.614200133884167826e+03 1.946407638075352205e-19 1.956288994058147772e-19 3.090752292376072825e-20 3.984608702978104458e-30 2.327769180991783521e-21 2.406998840962178196e-26 1.036488836039405401e-24 1.207163033672011869e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.014143463524713003e-20 0.000000000000000000e+00 1.816237146897058720e-20 1.991620883674294654e-19 2.617150143126425519e+03 1.947979598602713730e-19 1.958461052202754693e-19 3.137760868989669518e-20 3.963994180562327467e-30 2.326677795561185248e-21 2.399398812396625180e-26 1.034267282051280990e-24 1.206914154894012688e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.011293879754233871e-20 0.000000000000000000e+00 1.824153536457043801e-20 1.994546225913030043e-19 2.620150142962549126e+03 1.947672787784847274e-19 1.960669958192378267e-19 3.093168814155963891e-20 3.943030326285799858e-30 2.325576529798558048e-21 2.391669995555812823e-26 1.032008081807144689e-24 1.206686307089848054e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.030690567954584957e-20 0.000000000000000000e+00 1.832204076449410274e-20 1.996192126585911693e-19 2.623100133429908055e+03 1.958433681700494186e-19 1.962842081718044717e-19 3.202113832288811842e-20 3.922440045505663842e-30 2.324493621905476840e-21 2.384070017596259900e-26 1.029786541957772841e-24 1.206462257460949447e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.039378829330881689e-20 0.000000000000000000e+00 1.840120415626701481e-20 2.000158434960854083e-19 2.626050142641352522e+03 1.955910860693035193e-19 1.965014258118722453e-19 3.191095746157166888e-20 3.901876322758571926e-30 2.323410707131655436e-21 2.376469992471879927e-26 1.027564987992852872e-24 1.206210989447130248e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.028863635947540513e-20 0.000000000000000000e+00 1.848036805103998865e-20 2.002132682340856324e-19 2.629050142478584803e+03 1.952949121437417119e-19 1.967223283990004513e-19 2.835208820913373250e-20 3.880964128771231550e-30 2.322309441368620857e-21 2.368741179080048925e-26 1.025305787747881603e-24 1.205945167009237942e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.018889256873371712e-20 0.000000000000000000e+00 1.856690186559929624e-20 1.998972390983571935e-19 2.632000132978720558e+03 1.962589193655852328e-19 1.969395525028456561e-19 2.811111847085732264e-20 3.860789459113067904e-30 2.321226533463507477e-21 2.361141204463298879e-26 1.023084247873826761e-24 1.205683775773030508e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.068845445772566537e-20 0.000000000000000000e+00 1.865381067011884888e-20 2.001111486148367249e-19 2.634950142159556435e+03 1.971220146154775817e-19 1.971567818507221137e-19 2.881441778783261491e-20 3.840772047418527563e-30 2.320143618700922295e-21 2.353541182878136671e-26 1.020862693931957135e-24 1.205422382881714990e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.037149810328630230e-20 0.000000000000000000e+00 1.874072002498502853e-20 2.004162817056578644e-19 2.637950141997886476e+03 1.946257304389389473e-19 1.973776963067364656e-19 2.910822961498019348e-20 3.820415422009521794e-30 2.319042352937484474e-21 2.345812373036860240e-26 1.018603493686159162e-24 1.205156560444160850e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.052697877782655733e-20 0.000000000000000000e+00 1.882910213994306286e-20 2.006923684674280716e-19 2.640950141836583043e+03 1.976318532481134671e-19 1.975986147368957023e-19 3.031267262543085252e-20 3.800323870509988404e-30 2.317941087173912364e-21 2.338083564415992892e-26 1.016344293440085132e-24 1.204906562567098178e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.169325711519655504e-20 0.000000000000000000e+00 1.891748425491190045e-20 2.011603807708547036e-19 2.643950141675645682e+03 1.967487255604428542e-19 1.978195371278853161e-19 2.798009743645396018e-20 3.780256401707005626e-30 2.316839821410205966e-21 2.330354757027686759e-26 1.014085093193735596e-24 1.204678714763660094e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.052307591444506906e-20 0.000000000000000000e+00 1.900586636989152023e-20 2.009831639809871838e-19 2.646950141515073483e+03 1.968911372800304323e-19 1.980404634664499018e-19 2.995816802048260080e-20 3.760232320035563833e-30 2.315738555646365280e-21 2.322625950884258990e-26 1.011825892947110920e-24 1.204450866960301943e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.059929702758369268e-20 0.000000000000000000e+00 1.909424848488189814e-20 2.014975577316123504e-19 2.649950141354864627e+03 1.982947681779223021e-19 1.982613937393928670e-19 3.085721097507869243e-20 3.740454007838772202e-30 2.314637289882391434e-21 2.314897145998192612e-26 1.009566692700212759e-24 1.204193270569605207e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.058489574539405884e-20 0.000000000000000000e+00 1.918263059988298001e-20 2.018577932098631658e-19 2.652950141195018659e+03 1.981344861398556813e-19 1.984823279335761916e-19 2.978632391357321779e-20 3.720675695639588555e-30 2.313536024118284427e-21 2.307168342382134520e-26 1.007307492453041111e-24 1.203927448132569414e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.062221476331861866e-20 0.000000000000000000e+00 1.927101271489475380e-20 2.019244038322315912e-19 2.655950141035532852e+03 1.977874838796308743e-19 1.987032660359199706e-19 3.180351503898111944e-20 3.701008240405310575e-30 2.312436823874619517e-21 2.299439540048906673e-26 1.005048292205598365e-24 1.203662124268954321e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.068454479957371737e-20 0.000000000000000000e+00 1.935939482991713525e-20 2.024603500330755234e-19 2.658950140876407659e+03 1.986372823521828609e-19 1.989242080334022453e-19 2.698087957690961162e-20 3.681519084812542282e-30 2.311349323932302319e-21 2.291710739011497191e-26 1.002789091957884153e-24 1.203399624612608338e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.067372945668243793e-20 0.000000000000000000e+00 1.945175651727730543e-20 2.019848960787458355e-19 2.661950140717640807e+03 1.988989507156970648e-19 1.991451539130586425e-19 3.050676134260012993e-20 3.662029929217446432e-30 2.310261823989854971e-21 2.283981939283075285e-26 1.000529891709899945e-24 1.203137124956374827e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.073250120200381986e-20 0.000000000000000000e+00 1.954696451778482538e-20 2.027153424588754482e-19 2.664950140559231386e+03 1.959462137249156828e-19 1.993661036619819647e-19 3.044979268022842567e-20 3.642860063511146279e-30 2.309174324047278601e-21 2.276253140876986662e-26 9.982706914616466587e-25 1.202874625300253786e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.063756754479211250e-20 0.000000000000000000e+00 1.964217251830368726e-20 2.029280294650247361e-19 2.667950140401178487e+03 1.969720507331388178e-19 1.995870572673220464e-19 3.037796912931205744e-20 3.623888635939213703e-30 2.308086824104572832e-21 2.268524343806758690e-26 9.960114912131248455e-25 1.202612125644245782e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.072827089437558520e-20 0.000000000000000000e+00 1.973738051883386397e-20 2.031483398034155273e-19 2.671000149756641349e+03 1.993682535044260223e-19 1.998116980737936524e-19 3.098308102417477591e-20 3.604600957729429866e-30 2.306981195713217612e-21 2.260666710320419541e-26 9.937146304608311311e-25 1.202345250161456597e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.077836558906412573e-20 0.000000000000000000e+00 1.983417562137743023e-20 2.034723604855473982e-19 2.674050140080897563e+03 2.014922246477673400e-19 2.000363414379573043e-19 3.159337836168970534e-20 3.585544126829071583e-30 2.305907450971685742e-21 2.252809127274000871e-26 9.914177840403070705e-25 1.202110253054919921e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.072287586081339833e-20 0.000000000000000000e+00 1.993097011994658839e-20 2.037931926440451356e-19 2.677050139923917868e+03 1.993843332532992280e-19 2.002573066630664436e-19 3.162496844410504030e-20 3.566844127807578997e-30 2.304857451026628657e-21 2.245080334340553906e-26 9.891585837909771049e-25 1.201885253350040741e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.048092387192185227e-20 0.000000000000000000e+00 2.002617812051082397e-20 2.040117201862927981e-19 2.680100149248158687e+03 1.992518246215323084e-19 2.004819592411966797e-19 2.946729347413454501e-20 3.547850511761311627e-30 2.303785131750659135e-21 2.237222705187030399e-26 9.868617230621956652e-25 1.201649649391309176e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.076279164947975986e-20 0.000000000000000000e+00 2.012297322206352636e-20 2.039334707448808478e-19 2.683150139605808363e+03 1.998722623177582178e-19 2.007066143421257574e-19 3.014899861520029785e-20 3.529114856707177983e-30 2.302693159894216709e-21 2.229365126351743615e-26 9.845648766165241071e-25 1.201386070309881830e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.065444394060225449e-20 0.000000000000000000e+00 2.021976772169245756e-20 2.042577025862897682e-19 2.686150139449890503e+03 2.016426804853563225e-19 2.009275910708493380e-19 3.179651218937992115e-20 3.510686286236387431e-30 2.301619085875965279e-21 2.221636337686616796e-26 9.823056763663944380e-25 1.201126811390990904e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.041374384230740578e-20 0.000000000000000000e+00 2.031497572229039390e-20 2.047212727035302981e-19 2.689200148743116642e+03 1.983353572044798274e-19 2.011522553030853867e-19 2.983757562883124597e-20 3.492096051517641751e-30 2.300519946080620186e-21 2.213778713000947000e-26 9.800088156609691527e-25 1.200861502119887075e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.044441504337170453e-20 0.000000000000000000e+00 2.041655170047611922e-20 2.046586587056379250e-19 2.692250139133930588e+03 2.001038165283133645e-19 2.013769220237200868e-19 3.107819078931030997e-20 3.473853520756585523e-30 2.299414324563950143e-21 2.205921138514871076e-26 9.777119691903227477e-25 1.200594628297482532e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.065453853187633141e-20 0.000000000000000000e+00 2.052550640461673411e-20 2.050855016953449212e-19 2.695300148406481640e+03 2.001486436766364198e-19 2.016015940030143443e-19 3.035912810089982379e-20 3.455610877060527316e-30 2.298308696202650339e-21 2.198063516902627687e-26 9.754151085004672524e-25 1.200327752823077913e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.055632557951245564e-20 0.000000000000000000e+00 2.063446178326901053e-20 2.052043357167632839e-19 2.698350138819398580e+03 1.996905809281907077e-19 2.018262684479193371e-19 3.013067702122681921e-20 3.437398219991014539e-30 2.297215382397993117e-21 2.190205945412198958e-26 9.731182620131758474e-25 1.200063849824257264e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.065146870126363171e-20 0.000000000000000000e+00 2.074341648819921156e-20 2.054073046392707808e-19 2.701400148071366402e+03 2.004351954308694391e-19 2.020509481226108029e-19 2.820389656182038049e-20 3.419214355307853488e-30 2.296123403776918116e-21 2.182348326938506832e-26 9.708214013388207144e-25 1.199800269110868354e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.082968753719347624e-20 0.000000000000000000e+00 2.085237186611619501e-20 2.053749270661488708e-19 2.704450138506285839e+03 1.985831254275787659e-19 2.022756302403404791e-19 2.849960214151499413e-20 3.401030602810142670e-30 2.295040692862024495e-21 2.174490758510287378e-26 9.685245548349599819e-25 1.199536690023788291e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.056903288011253203e-20 0.000000000000000000e+00 2.096132657183238911e-20 2.056342522052554599e-19 2.707500147737761381e+03 2.007322853019786986e-19 2.025003175592247908e-19 3.223994744382304520e-20 3.383192082559362177e-30 2.293986368683242853e-21 2.166633143242173800e-26 9.662276941760370694e-25 1.199273109312463172e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.055355341115963361e-20 0.000000000000000000e+00 2.107028194901732660e-20 2.064166362582365336e-19 2.710600147568799912e+03 2.045069133516505553e-19 2.027286914708801632e-19 3.317383082505548766e-20 3.365175612953091414e-30 2.292914763803377694e-21 2.158646740858791964e-26 9.638931872568118963e-25 1.199005208431481335e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.069106569447720881e-20 0.000000000000000000e+00 2.118102313870895168e-20 2.068068062142161241e-19 2.713650138036712178e+03 2.040205278434170635e-19 2.029533850644360245e-19 3.045768943816860561e-20 3.347449785998401003e-30 2.291845682889455278e-21 2.150789177179183691e-26 9.615963407281052539e-25 1.198743579198941629e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.067241734114504128e-20 0.000000000000000000e+00 2.128997784560374870e-20 2.066194582979130255e-19 2.716700147237453621e+03 1.998283341276444427e-19 2.031780838164149507e-19 3.011179083973249706e-20 3.330191725391890314e-30 2.290767021098949322e-21 2.142931566876865068e-26 9.592994800923270905e-25 1.198483212889593672e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.060790474862203695e-20 0.000000000000000000e+00 2.139893322169077371e-20 2.067974362837832841e-19 2.719800147069634022e+03 2.028445073694642900e-19 2.034064693120659060e-19 3.093326138516022463e-20 3.312658703085233545e-30 2.289670679694885707e-21 2.134945169512338728e-26 9.569649731722419698e-25 1.198218579092869593e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.061139295965399467e-20 0.000000000000000000e+00 2.151241178304139353e-20 2.071548267834745689e-19 2.722900146902196411e+03 2.020834885956132561e-19 2.036348586849751198e-19 3.102540923641175029e-20 3.295133759361255119e-30 2.288597480083191455e-21 2.127634876179322216e-26 9.547826632248654965e-25 1.197986693074325243e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.059999462206338497e-20 0.000000000000000000e+00 2.163636661068743471e-20 2.074051513041350206e-19 2.726000146735139424e+03 2.031689996076339239e-19 2.038632519221116537e-19 3.002916686731633746e-20 3.277642466186202748e-30 2.287525875202667644e-21 2.120990832122218573e-26 9.527503319667617913e-25 1.197757063748243369e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.042467832080434366e-20 0.000000000000000000e+00 2.176032143834869375e-20 2.074869375447949885e-19 2.729050137257772349e+03 2.007019566628250020e-19 2.040879644698238222e-19 3.263720619342236078e-20 3.260433343190264458e-30 2.286463975847860948e-21 2.114453971058864102e-26 9.507507863505988485e-25 1.197520410084051812e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.052559132850323717e-20 0.000000000000000000e+00 2.188227662221156405e-20 2.081186405540923140e-19 2.732100146407522061e+03 2.042121757017492954e-19 2.043126821056216385e-19 3.135212362987291169e-20 3.243412218354925948e-30 2.285385314075388392e-21 2.107917071107146597e-26 9.487512285226703134e-25 1.197260043779730834e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.062890307246580168e-20 0.000000000000000000e+00 2.200423255088772081e-20 2.081596598155364392e-19 2.735200146241587390e+03 2.028377007786774917e-19 2.045410867346293157e-19 2.956945669570469744e-20 3.226369428569506226e-30 2.284288972670658224e-21 2.101273030217880269e-26 9.467188972638308223e-25 1.196995409983531119e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.052794860776749592e-20 0.000000000000000000e+00 2.212818737859385702e-20 2.081310983140942388e-19 2.738300146076028796e+03 2.032381024975535061e-19 2.047694951767294526e-19 3.028866259490126670e-20 3.209326638782018887e-30 2.283217023291112084e-21 2.094628990416229183e-26 9.446865660047446609e-25 1.196730776187447826e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.048359564863926701e-20 0.000000000000000000e+00 2.225214220631502753e-20 2.084698013925125312e-19 2.741400145910844458e+03 2.038248596039907574e-19 2.049979074191762930e-19 2.929202505539370963e-20 3.192451303068730734e-30 2.282158486762150672e-21 2.087984951712587110e-26 9.426542347454132988e-25 1.196466142391481706e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.037482665656236790e-20 0.000000000000000000e+00 2.237609703405116612e-20 2.085596588609494200e-19 2.744500145746033922e+03 2.027126130947594347e-19 2.052263234492808476e-19 3.071540602319684237e-20 3.175668048147054045e-30 2.281099949076686759e-21 2.081340914117477535e-26 9.406219034858369196e-25 1.196201508745532363e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.041314308951385327e-20 0.000000000000000000e+00 2.250005186180225173e-20 2.090038282002929450e-19 2.747600145581594916e+03 2.028835526654750536e-19 2.054547432544100990e-19 2.925724332641781692e-20 3.158884793223365091e-30 2.280016816604021051e-21 2.074696877641563134e-26 9.385895722260168090e-25 1.195940063308783728e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.061696354976498579e-20 0.000000000000000000e+00 2.262400668956819108e-20 2.090426563089549592e-19 2.750750154957734594e+03 2.056294457148616947e-19 2.056868518070110050e-19 3.086664139018149646e-20 3.142048243085946077e-30 2.278916210918381984e-21 2.067945659991949090e-26 9.365244551732939924e-25 1.195674400205451349e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.036314317483360740e-20 0.000000000000000000e+00 2.275023886948161997e-20 2.095027965429462577e-19 2.753900145248552690e+03 2.057491853984778033e-19 2.059189628249288938e-19 3.058921624176825634e-20 3.125243411162372041e-30 2.277824340646835774e-21 2.061194484425735633e-26 9.344593506327317780e-25 1.195407607209237528e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.059790997628023042e-20 0.000000000000000000e+00 2.288799008417454320e-20 2.097167438977788539e-19 2.757000145085234180e+03 2.058343286795268860e-19 2.061473940002490470e-19 3.228982434562591675e-20 3.108759245556781529e-30 2.276765804117237150e-21 2.054550451410094623e-26 9.324270193721771671e-25 1.195142973413856710e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.058282484280605661e-20 0.000000000000000000e+00 2.302355518235770086e-20 2.102095932976832989e-19 2.760100144922281743e+03 2.079571753780329131e-19 2.063758289002190329e-19 3.087965719419277422e-20 3.092639246404134851e-30 2.275707267587513641e-21 2.047906419558046370e-26 9.303946881113826819e-25 1.194878339618593818e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.097429813670686435e-20 0.000000000000000000e+00 2.315912028055686481e-20 2.102568016334459846e-19 2.763200144759695377e+03 2.061475716684391821e-19 2.066042675124841311e-19 3.031933013900108575e-20 3.076519247249584509e-30 2.274657782490705066e-21 2.041262388880962405e-26 9.283623568503479550e-25 1.194615968678824519e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.092601660247015196e-20 0.000000000000000000e+00 2.329468537877203804e-20 2.104119923301512344e-19 2.766350154083896996e+03 2.082757850858650252e-19 2.068363951076833695e-19 3.142764458055927638e-20 3.060221279772592583e-30 2.273595128742781704e-21 2.034511177296933936e-26 9.262972398316753526e-25 1.194350305580622185e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.078438631220592672e-20 0.000000000000000000e+00 2.343243742580774935e-20 2.108102677888087864e-19 2.769500144430399359e+03 2.083793478238981675e-19 2.070685251118207120e-19 3.216956971379084000e-20 3.044087536112805517e-30 2.272532481396973725e-21 2.027760007624697942e-26 9.242321352546070591e-25 1.194084644083097279e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.064401242963959068e-20 0.000000000000000000e+00 2.357018864293578530e-20 2.111579843238041661e-19 2.772600144268913937e+03 2.038756929789824329e-19 2.072969749057498853e-19 3.190531396383769110e-20 3.028209835790482290e-30 2.271486698318920853e-21 2.021115980581468795e-26 9.221998039928506889e-25 1.193823198647280012e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.068517952756588984e-20 0.000000000000000000e+00 2.370575374119910077e-20 2.113591861090545899e-19 2.775750153562096330e+03 2.024807094846887792e-19 2.075291138227619653e-19 3.227864927036073735e-20 3.012204742017555001e-30 2.270424044581461459e-21 2.014364772795530590e-26 9.201346869945139552e-25 1.193557535552143931e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.060418826510137135e-20 0.000000000000000000e+00 2.384350578687832244e-20 2.116548730020889777e-19 2.778900143941843908e+03 2.042422348909442852e-19 2.077612551153802724e-19 2.874942690896085625e-20 2.996302721617725332e-30 2.269351140781982453e-21 2.007613606821149859e-26 9.180695823956503433e-25 1.193277701531709119e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.079733142394986135e-20 0.000000000000000000e+00 2.398125700546019174e-20 2.113989725501728505e-19 2.782050153214352576e+03 2.048917260570595912e-19 2.079934015571439583e-19 3.383964681398890646e-20 2.980400605842025942e-30 2.268263637580759324e-21 2.000862401643721148e-26 9.160044654108670594e-25 1.192977701032048957e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.059467571382939378e-20 0.000000000000000000e+00 2.411900905023533676e-20 2.123838947646868586e-19 2.785200143616254081e+03 2.067319676089405002e-19 2.082255503524386457e-19 3.057637605548446269e-20 2.964823839123694877e-30 2.267176140894388446e-21 1.994111238212044614e-26 9.139393607974794802e-25 1.192677702329780408e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.071094962400020895e-20 0.000000000000000000e+00 2.427494303226221766e-20 2.121399407511960574e-19 2.788350152868179521e+03 2.072664558800090852e-19 2.084577042686995161e-19 3.231748119998666747e-20 2.949331520893771234e-30 2.266107177345674627e-21 1.987360035695284517e-26 9.118742438261905041e-25 1.192403320218785120e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.072372127383277310e-20 0.000000000000000000e+00 2.443438439029258622e-20 2.126443708797124530e-19 2.791500143292133089e+03 2.101222300403729297e-19 2.086898605166255109e-19 3.118650473119355075e-20 2.933839297703843937e-30 2.265044529973738324e-21 1.980608874859594846e-26 9.098091391983458138e-25 1.192137658715836202e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.066941107663758608e-20 0.000000000000000000e+00 2.459382479532340014e-20 2.127188288100772229e-19 2.794650152523568067e+03 2.069764511525653702e-19 2.089220218575740100e-19 3.155126676413856143e-20 2.918400631769546233e-30 2.263983282492143935e-21 1.973857675057091957e-26 9.077440222404901667e-25 1.191872347185176254e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.075094815216102347e-20 0.000000000000000000e+00 2.475326615231661931e-20 2.130228788268436922e-19 2.797850152349121345e+03 2.062434829481845637e-19 2.091578713780568508e-19 3.273587637963782354e-20 2.902716954463615825e-30 2.262916615883626367e-21 1.966999335214323551e-26 9.056461319108560722e-25 1.191605680874672510e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.070596732625581085e-20 0.000000000000000000e+00 2.491523784099381562e-20 2.134492452348720893e-19 2.801000142806137319e+03 2.064782411279106765e-19 2.093900387704243281e-19 3.260655960468003971e-20 2.887377499594315913e-30 2.261866619064621031e-21 1.960248178397205386e-26 9.035810272613360007e-25 1.191343182006357439e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.082011819577826713e-20 0.000000000000000000e+00 2.507467824769812423e-20 2.136813652439681882e-19 2.804150152006843200e+03 2.067464011892479921e-19 2.096222112141168431e-19 3.391899847917236779e-20 2.872329046549125846e-30 2.260816615997719152e-21 1.953496982792271142e-26 9.015159103236261228e-25 1.191080681576218320e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.089796181240921938e-20 0.000000000000000000e+00 2.523411960313595636e-20 2.141355323660935848e-19 2.807350151833575637e+03 2.084415454925964438e-19 2.098580719781508696e-19 3.162749169762073191e-20 2.857041774649599944e-30 2.259749949388808122e-21 1.946638647188120412e-26 8.994180199932189570e-25 1.190814015266070798e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.089606914748918779e-20 0.000000000000000000e+00 2.539609129187283543e-20 2.140348543810186645e-19 2.810550151660703250e+03 2.077861032062988994e-19 2.100939365041845048e-19 2.953986559871454604e-20 2.841949182162571606e-30 2.258683282779765438e-21 1.939780313041822885e-26 8.973201296625528152e-25 1.190547348956043458e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.075483832919438376e-20 0.000000000000000000e+00 2.555806298062971709e-20 2.139800598191124605e-19 2.813700142161563235e+03 2.084596719761660020e-19 2.103261186213279258e-19 3.409700615316325372e-20 2.827296417360818656e-30 2.257643482582073360e-21 1.933029161800450952e-26 8.952550249842889681e-25 1.190287399240381464e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.125915274671803485e-20 0.000000000000000000e+00 2.571750338955324168e-20 2.149287189816112991e-19 2.816850151321507838e+03 2.082405207655818157e-19 2.105583057348664551e-19 3.188919942083667385e-20 2.812643565762874243e-30 2.256605832505855975e-21 1.926277972011927327e-26 8.931899080733017502e-25 1.190027987054543561e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.084627425886368965e-20 0.000000000000000000e+00 2.589256424351905659e-20 2.148168897906634756e-19 2.820050151149798239e+03 2.101985269007594501e-19 2.107941813549957900e-19 3.162714406781723598e-20 2.797781343982072885e-30 2.255549949616733766e-21 1.919419642285983609e-26 8.910920177418731900e-25 1.189764016671483313e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.110213438845269317e-20 0.000000000000000000e+00 2.607906367034799698e-20 2.150449746673835846e-19 2.823250150978478359e+03 2.105123265182884728e-19 2.110300606872273313e-19 2.985401946677318533e-20 2.782930435686243352e-30 2.254483283007173864e-21 1.912561314080846040e-26 8.889941274101893272e-25 1.189497350361931061e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.101399309425825176e-20 0.000000000000000000e+00 2.626556309719965431e-20 2.150410064157094951e-19 2.826450150807545924e+03 2.096297275599124854e-19 2.112659437191272513e-19 3.272005754891400062e-20 2.768079527388615603e-30 2.253416616397484564e-21 1.905702987412947719e-26 8.868962370782512638e-25 1.189230684052500308e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.098366997407919557e-20 0.000000000000000000e+00 2.645206252407389016e-20 2.157098651343247754e-19 2.829650150637000934e+03 2.107010233685506318e-19 2.115018304383172129e-19 3.162060028939882877e-20 2.753594600493545716e-30 2.252356420966634993e-21 1.898844662298955068e-26 8.847983467460591833e-25 1.188946222023932199e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.087100289459825233e-20 0.000000000000000000e+00 2.663856195097070454e-20 2.157942655204717139e-19 2.832850150466840660e+03 2.088736107977146685e-19 2.117377208324737443e-19 3.111276965856054006e-20 2.739140668677865397e-30 2.251302303375629015e-21 1.891986338755780454e-26 8.827004564136151063e-25 1.188645045957108273e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.096119898153989070e-20 0.000000000000000000e+00 2.682506137788994395e-20 2.159793506335355173e-19 2.836050150297064192e+03 2.251467313770538190e-19 2.119736148893277808e-19 3.058067614105804768e-20 2.724715060924086945e-30 2.250248185784496271e-21 1.885128016800580183e-26 8.806025660809192163e-25 1.188343869890444592e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.080548755875527381e-20 0.000000000000000000e+00 2.701156080483155124e-20 2.161500634277385531e-19 2.839250150127670622e+03 3.044330974085470940e-19 2.122095125966651712e-19 3.446139381600405203e-20 2.710462477408891639e-30 2.249194068193237891e-21 1.878269696450759091e-26 8.785046757479724317e-25 1.188075048489619372e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.082483504034670226e-20 0.000000000000000000e+00 2.719806023179547224e-20 2.169881260146009847e-19 2.842500159484017786e+03 2.551779466441287849e-19 2.124491006320568028e-19 3.285217787575837817e-20 2.695987154837475631e-30 2.248123476875852813e-21 1.871304196086211786e-26 8.763739996318503406e-25 1.187807401005351694e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.091902022022004262e-20 0.000000000000000000e+00 2.738747426763036294e-20 2.170014968755688302e-19 2.845750149784762925e+03 2.559871120450666498e-19 2.126886910028713369e-19 3.471787431815982282e-20 2.681651571823496125e-30 2.247055765186356358e-21 1.864338738255873467e-26 8.742433360084050328e-25 1.187540473427282791e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.084097067309877569e-20 0.000000000000000000e+00 2.757688719288430539e-20 2.175460432708970635e-19 2.848950149616521685e+03 3.283269341136353195e-19 2.129245997016595591e-19 3.341083257466641243e-20 2.667756461442925890e-30 2.246013904776016274e-21 1.857480422881353738e-26 8.721454456747028094e-25 1.187280008660816368e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.094189486496740918e-20 0.000000000000000000e+00 2.777378964678411521e-20 2.176022324312518755e-19 2.852150149448657885e+03 2.417955041015166633e-19 2.131605120022368131e-19 3.344296611118473251e-20 2.653861351060716836e-30 2.244972044365553186e-21 1.851390228954558575e-26 8.702274315733761055e-25 1.187019543894466365e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.104547063061769232e-20 0.000000000000000000e+00 2.798232087759995168e-20 2.178699095289517445e-19 2.855400158763508443e+03 2.145572195459194017e-19 2.134001148061371779e-19 3.083380684313540326e-20 2.639784482110134364e-30 2.243928184863356079e-21 1.845602440986503389e-26 8.683725475385163519e-25 1.186732106467183707e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.093910190554810372e-20 0.000000000000000000e+00 2.819411102701889357e-20 2.177414706443444351e-19 2.858650149108841106e+03 2.224310077776797737e-19 2.136397199019385209e-19 2.969452033029130089e-20 2.625732838459752407e-30 2.242895834988956472e-21 1.839814687851129294e-26 8.665176743301658319e-25 1.186426225418196390e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.108100508322576611e-20 0.000000000000000000e+00 2.840589994026998675e-20 2.178527403365909083e-19 2.861850148942114174e+03 2.134850364328516074e-19 2.138756430476703923e-19 3.063494450535999266e-20 2.611897333562634879e-30 2.241879364453681478e-21 1.834115961475888956e-26 8.646913323024155197e-25 1.186125049352698234e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.094757031300709123e-20 0.000000000000000000e+00 2.861443117115990533e-20 2.182346406906423713e-19 2.865100158226002804e+03 2.183774301823767598e-19 2.141152568271109519e-19 3.198816895546444043e-20 2.598131332637881760e-30 2.240823204298510730e-21 1.828328176728700058e-26 8.628364482852267522e-25 1.185857335379943043e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.101149476528552724e-20 0.000000000000000000e+00 2.882622131856118282e-20 2.186943477978642897e-19 2.868350148604594779e+03 2.436739209870586149e-19 2.143548728662689728e-19 3.318021037256794626e-20 2.584423595441064918e-30 2.239765067896178222e-21 1.822540426729872055e-26 8.609815750578940188e-25 1.185592801621700077e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.084689476483915322e-20 0.000000000000000000e+00 2.903801023397965136e-20 2.191260395864961040e-19 2.871600157867851067e+03 2.177773076606154014e-19 2.145944939390925538e-19 3.290534911166012056e-20 2.570738252973306212e-30 2.238706925345350855e-21 1.816752644191427284e-26 8.591266910524807660e-25 1.185328266326488090e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.119190974404551899e-20 0.000000000000000000e+00 2.924980038003640106e-20 2.193645032991009608e-19 2.874850148268601515e+03 2.184965010231148044e-19 2.148341172503231572e-19 3.236196550225032809e-20 2.557395435240115226e-30 2.237648788935804010e-21 1.810964896345918392e-26 8.572718178125017337e-25 1.185063732566747261e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.119447433699167719e-20 0.000000000000000000e+00 2.946158929689884761e-20 2.195465957248330089e-19 2.878100157511316866e+03 2.571274150497959461e-19 2.150737455677987968e-19 3.241775474939285321e-20 2.544052540151340789e-30 2.236590646391664359e-21 1.805177116057905037e-26 8.554169338188118330e-25 1.184799197273513491e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.094755380185864597e-20 0.000000000000000000e+00 2.967337944161702784e-20 2.198053487176193974e-19 2.881350147934124379e+03 3.628274169144056233e-19 2.153133761025736517e-19 3.304616951724058220e-20 2.530720061122984227e-30 2.235540182274074830e-21 1.799389370408282155e-26 8.535620605662439909e-25 1.184513016696355527e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.177953052300636771e-20 0.000000000000000000e+00 2.989738759631429664e-20 2.202065191691640408e-19 2.884600157156389741e+03 2.165777697820146429e-19 2.155530116164019159e-19 3.291085938122225607e-20 2.517416690039844754e-30 2.234494202294495410e-21 1.793601592413470303e-26 8.517071765842254634e-25 1.184214165661259455e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.139523950228749105e-20 0.000000000000000000e+00 3.015301092999257746e-20 2.204351976473494259e-19 2.887900156976807466e+03 2.134211719951911233e-19 2.157963367906898635e-19 3.416429434502418457e-20 2.503908690774934824e-30 2.233432133386774379e-21 1.787724789847673424e-26 8.498237613724712479e-25 1.183910717795714335e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.124912079571176842e-20 0.000000000000000000e+00 3.041256617969889663e-20 2.208916357517641666e-19 2.891150147432678750e+03 2.150199655165603942e-19 2.160359781255560899e-19 3.364755788944971305e-20 2.490773917059901991e-30 2.232411000224624122e-21 1.781937047591680347e-26 8.479688881010328644e-25 1.183645129823728923e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.126160050282211744e-20 0.000000000000000000e+00 3.066818803734191621e-20 2.210824463302213121e-19 2.894400156624281863e+03 2.125145064609662473e-19 2.162756243989065409e-19 3.252272968683419374e-20 2.477802451802866097e-30 2.231390648501679023e-21 1.776149273137646604e-26 8.461140041365143253e-25 1.183380594535477556e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.132336571583100498e-20 0.000000000000000000e+00 3.092381136860851746e-20 2.211871467122117313e-19 2.897700156445912853e+03 2.184309834835015658e-19 2.165189604639986289e-19 3.386013675423446766e-20 2.464631463503784783e-30 2.230345926661085768e-21 1.770272474144358432e-26 8.442305889240674864e-25 1.183100374069570538e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.150290191749013208e-20 0.000000000000000000e+00 3.118336661841026044e-20 2.216710679763337577e-19 2.901000156267949478e+03 2.173408761268827659e-19 2.167623001718972899e-19 2.959062257048279114e-20 2.451608177127266276e-30 2.229283857752843759e-21 1.764395676377962642e-26 8.423471737113892221e-25 1.182796926204618244e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.112284758993527847e-20 0.000000000000000000e+00 3.144292186824390765e-20 2.213148063502277949e-19 2.904300156090391283e+03 2.135401002103720106e-19 2.170056435103479760e-19 3.123854072819355985e-20 2.438640265737099057e-30 2.228221788844471598e-21 1.758518879850767774e-26 8.404637584984797160e-25 1.182493478339831647e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.139420325764720371e-20 0.000000000000000000e+00 3.170247711810942298e-20 2.218299662564582041e-19 2.907600155913234630e+03 2.150044310810459039e-19 2.172489904671507878e-19 3.125136227791367703e-20 2.425672354345353976e-30 2.227186158509685716e-21 1.752642084575253123e-26 8.385803432853409884e-25 1.182216469014506633e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.138176886206303153e-20 0.000000000000000000e+00 3.196203236800652356e-20 2.221063836845133960e-19 2.910900155736480883e+03 2.178731971691102498e-19 2.174923410301603536e-19 3.236785385461894800e-20 2.412873242375489014e-30 2.226162020633506214e-21 1.746765290564056402e-26 8.366969280719724885e-25 1.181950952133081531e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.142246862784066707e-20 0.000000000000000000e+00 3.222158761793531171e-20 2.225435972437839831e-19 2.914150146269063043e+03 2.218606863744932138e-19 2.177320072909711140e-19 3.429401985744437730e-20 2.400273279079940429e-30 2.225152226187116378e-21 1.740977556685263420e-26 8.348420547567526342e-25 1.181687890058112392e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.150626667048057971e-20 0.000000000000000000e+00 3.248234008503253626e-20 2.231079359333206217e-19 2.917400155389498195e+03 2.183159043726372054e-19 2.179716783970286766e-19 3.530828754732398836e-20 2.387735065747459508e-30 2.224118132376068693e-21 1.735189790956183246e-26 8.329871708328520168e-25 1.181392435068596961e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.133527742200574915e-20 0.000000000000000000e+00 3.279032628189554225e-20 2.235360466566762979e-19 2.920750164769318872e+03 2.181968726703576862e-19 2.182187276215130159e-19 3.032151229340323043e-20 2.375092421653179339e-30 2.223052220300671237e-21 1.729223941489064358e-26 8.310752135695710200e-25 1.181087889158459884e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.136559741937354410e-20 0.000000000000000000e+00 3.310778897511045794e-20 2.230929102829086063e-19 2.924100155033454030e+03 2.190377582730485140e-19 2.184657791032435352e-19 3.336436112733105005e-20 2.362449849699834502e-30 2.222001088796554105e-21 1.723258127421372682e-26 8.291632672162217032e-25 1.180798119456051679e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.150484372396875191e-20 0.000000000000000000e+00 3.342524985683282636e-20 2.238222901398610490e-19 2.927400154858687529e+03 2.169723184070313049e-19 2.187091475169880503e-19 3.414392813442589045e-20 2.350068988873754000e-30 2.220988588850175626e-21 1.717381339927501490e-26 8.272798520017188512e-25 1.180535619812578393e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.133774724034507431e-20 0.000000000000000000e+00 3.373797340872432133e-20 2.242155678217200789e-19 2.930700154684315294e+03 2.209347771640431170e-19 2.189525194651925068e-19 3.100118753692673154e-20 2.337787250392286843e-30 2.219976088903676025e-21 1.711504553777495273e-26 8.253964367869909104e-25 1.180273120169226043e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.142035911415068628e-20 0.000000000000000000e+00 3.405069696065318536e-20 2.240479308402840122e-19 2.934000154510334596e+03 2.222419544270807585e-19 2.191958949360841281e-19 3.525239625399477583e-20 2.325505511909362685e-30 2.218936314473984703e-21 1.705627768985257926e-26 8.235130215720396257e-25 1.179983346078563138e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.119651244757074775e-20 0.000000000000000000e+00 3.436342051261915364e-20 2.249490929044577386e-19 2.937300154336745436e+03 2.237566507197045765e-19 2.194392739179418974e-19 3.076113267409986704e-20 2.313333346694724917e-30 2.217886314529217260e-21 1.699750985564878162e-26 8.216296063568648134e-25 1.179683346486468498e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.108726476594301634e-20 0.000000000000000000e+00 3.467614406462222014e-20 2.245696223922219956e-19 2.940650163654289827e+03 2.233310044387569777e-19 2.196863447394615285e-19 3.085712481106439001e-20 2.301040269025127550e-30 2.216823245242433934e-21 1.693785144483155688e-26 8.197176491291268168e-25 1.179381643348224943e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.167590905681990820e-20 0.000000000000000000e+00 3.499360675193553880e-20 2.249031721195521964e-19 2.944000153985503403e+03 2.199172572876562068e-19 2.199334177546430516e-19 3.359691007427063707e-20 2.288747261027109621e-30 2.215795407299902312e-21 1.687819338657446957e-26 8.178057027374936693e-25 1.179115167193257948e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.113056275885753115e-20 0.000000000000000000e+00 3.531106764001457742e-20 2.255582443616661698e-19 2.947300153813090674e+03 2.207200895128988690e-19 2.201768073047476863e-19 3.431205775008192574e-20 2.276914288951921009e-30 2.214782907352801609e-21 1.681942559482296164e-26 8.159222875216474477e-25 1.178852667550576099e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.113392017365270232e-20 0.000000000000000000e+00 3.562379119212913120e-20 2.259523343913382521e-19 2.950650163099651763e+03 2.199043279659462201e-19 2.204238888164491893e-19 3.529396733569812967e-20 2.264940707372857484e-30 2.213755063594424982e-21 1.675976722812979425e-26 8.140103303115926514e-25 1.178569710783565709e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.108176107210160424e-20 0.000000000000000000e+00 3.598709900308127860e-20 2.263990312547385543e-19 2.954000153464225605e+03 2.215369420105626543e-19 2.206709724905418856e-19 3.289295144824022180e-20 2.252982685216340228e-30 2.212727225641658095e-21 1.670010921331598776e-26 8.120983839009197097e-25 1.178265166603990099e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.108701984482367462e-20 0.000000000000000000e+00 3.635501501108625963e-20 2.263371775728223635e-19 2.957350162730142529e+03 2.211505593139845416e-19 2.209180611048051747e-19 3.306021443783547827e-20 2.241182007415110549e-30 2.211699381889615219e-21 1.664045087696837061e-26 8.101864267026471321e-25 1.177960620706319092e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.122217355789912764e-20 0.000000000000000000e+00 3.672293309494995621e-20 2.266683870800653255e-19 2.960700153116939873e+03 2.212482206264571668e-19 2.211651518607580288e-19 3.241503196449364497e-20 2.229381396117102059e-30 2.210650513626131401e-21 1.658079289205954792e-26 8.082744802792906063e-25 1.177658834594159964e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.143505769838145615e-20 0.000000000000000000e+00 3.709084910539565622e-20 2.268865888135601441e-19 2.964050162362304036e+03 2.229112244151288987e-19 2.214122475300489383e-19 3.371694642372642593e-20 2.217630403489283347e-30 2.209596578133207744e-21 1.652113458670653126e-26 8.063625230927481766e-25 1.177357710562760525e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.121658670786973235e-20 0.000000000000000000e+00 3.745876718700212679e-20 2.273663461857548027e-19 2.967400152771221201e+03 2.278661234490617893e-19 2.216593453205253847e-19 3.140683631381829545e-20 2.205988286283240157e-30 2.208548268260416008e-21 1.646147663236460245e-26 8.044505766567671171e-25 1.177062207911403634e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.123623523456065986e-20 0.000000000000000000e+00 3.782668319987715872e-20 2.273381376735084362e-19 2.970750161996124916e+03 2.207591748813355586e-19 2.219064479977316237e-19 3.356074489460034479e-20 2.194346103686585738e-30 2.207531973327018375e-21 1.640181835867416898e-26 8.025386194819021217e-25 1.176798724385878024e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.129591964637265210e-20 0.000000000000000000e+00 3.819460127923653850e-20 2.279506057936300140e-19 2.974100152427061403e+03 2.240879697983563486e-19 2.221535527758150461e-19 3.315714334118401102e-20 2.182804640088113028e-30 2.206515684095161053e-21 1.634216043558030663e-26 8.006266730333540173e-25 1.176535242338682698e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.137450874124996257e-20 0.000000000000000000e+00 3.856251729452985835e-20 2.281979344821995711e-19 2.977450161631593346e+03 2.245620729826501860e-19 2.224006624142415763e-19 3.548404689057686628e-20 2.171349769904874490e-30 2.205504951510522208e-21 1.628250219424018942e-26 7.987147158701157631e-25 1.176254865796861196e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.145353043145597770e-20 0.000000000000000000e+00 3.893043537165189132e-20 2.288540631315848244e-19 2.980850161447234314e+03 2.238393380438622906e-19 2.226514630953835279e-19 3.272897675028525911e-20 2.159723964083650469e-30 2.204484951565829585e-21 1.622195371766030937e-26 7.967742274697468594e-25 1.175952643988565035e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.152467838976317152e-20 0.000000000000000000e+00 3.930384371712557348e-20 2.287547002789691837e-19 2.984250161263294558e+03 2.239431705430702389e-19 2.229022673326537215e-19 3.387179946472999687e-20 2.148318610934370493e-30 2.203464951621011702e-21 1.616140525800870452e-26 7.948337390691386323e-25 1.175650422180436075e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.145531224592249397e-20 0.000000000000000000e+00 3.975735389998451986e-20 2.292396744918670034e-19 2.987600151738291970e+03 2.219545011931931128e-19 2.231493860494195752e-19 3.423763045517820320e-20 2.137142472498634213e-30 2.202450515764787689e-21 1.611012946535948455e-26 7.931280684582899795e-25 1.175349848989183001e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.148698243676277308e-20 0.000000000000000000e+00 4.023356464802374591e-20 2.296187852928820407e-19 2.990950160902050357e+03 2.235766883128885444e-19 2.233965095740257605e-19 3.368238562761878701e-20 2.125966271714010664e-30 2.201434220849939921e-21 1.606052774446077792e-26 7.914635926645695000e-25 1.175048724966673309e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.165806378505288454e-20 0.000000000000000000e+00 4.070977805272390537e-20 2.298693696961498942e-19 2.994350160719351152e+03 2.251541565814284258e-19 2.236473243045841336e-19 3.174060290163137060e-20 2.114780109633794094e-30 2.200404951784194649e-21 1.601018585018022181e-26 7.897742786603647846e-25 1.174750980755045381e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.173485682995911970e-20 0.000000000000000000e+00 4.119309777211244765e-20 2.299269265059748202e-19 2.997750160537065312e+03 2.251710455825677492e-19 2.238981425439776131e-19 3.319675662780813068e-20 2.103596280446164085e-30 2.199384951838880237e-21 1.595984396646695526e-26 7.880849646559546332e-25 1.174486536673505078e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.173091831053160148e-20 0.000000000000000000e+00 4.167641749155974885e-20 2.304629207009251497e-19 3.001150160355193293e+03 2.302902864967642596e-19 2.241489642804273559e-19 3.750334895159041103e-20 2.092450757317863795e-30 2.198364951893442069e-21 1.590950209342133725e-26 7.863956506513389539e-25 1.174222092592089660e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.282103158534931609e-20 0.000000000000000000e+00 4.215973721106587517e-20 2.315108923351012163e-19 3.004550160173732365e+03 2.269994656706336404e-19 2.243997895022068561e-19 3.537202148619297089e-20 2.081440545139531030e-30 2.197324394612616630e-21 1.585916023114505263e-26 7.847063366465190325e-25 1.173937091202675989e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.173064433349950853e-20 0.000000000000000000e+00 4.264305693063044143e-20 2.314491091296912750e-19 3.007950159992682075e+03 2.276175353084903689e-19 2.246506181976418484e-19 3.450480142425791271e-20 2.070430332959868082e-30 2.196266616891165440e-21 1.580881837974105188e-26 7.830170226414950527e-25 1.173634869395657449e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.168219214643619957e-20 0.000000000000000000e+00 4.312637665025338142e-20 2.316485280780095888e-19 3.011350159812040602e+03 2.251227840473280804e-19 2.249014503551100199e-19 3.219990477496458058e-20 2.059538231499611096e-30 2.195208839169587485e-21 1.575847653931361418e-26 7.813277086362679327e-25 1.173332647588807803e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.146042842340634258e-20 0.000000000000000000e+00 4.360969636993443635e-20 2.316394589193190382e-19 3.014750159631806127e+03 2.279123360474590830e-19 2.251522859630406241e-19 3.019678321258020867e-20 2.048787074174794686e-30 2.194184952110458224e-21 1.570813470996836472e-26 7.796383946308385909e-25 1.173030425782127993e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.160187717171880243e-20 0.000000000000000000e+00 4.409301608967334139e-20 2.317118591292948655e-19 3.018150159451978197e+03 2.280218540819707814e-19 2.254031250099144334e-19 3.428339085962017700e-20 2.038035916848692936e-30 2.193164952164406541e-21 1.565779289181225166e-26 7.779490806252073029e-25 1.172728203975618019e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.146207092923244713e-20 0.000000000000000000e+00 4.465677464039107057e-20 2.326235403154445862e-19 3.021600168784745620e+03 2.276527977590479273e-19 2.256576570716775937e-19 3.210873041586223576e-20 2.027242843233992340e-30 2.192132916953976415e-21 1.560671062346893679e-26 7.762349190388375690e-25 1.172422416169773821e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.170052394796592366e-20 0.000000000000000000e+00 4.530003563570048567e-20 2.326962059744428407e-19 3.025050159088275450e+03 2.292837351988389959e-19 2.259121912465723408e-19 3.494519361089788878e-20 2.016507926036903554e-30 2.191109293457324856e-21 1.555562864863342023e-26 7.745207669072794864e-25 1.172119120720478316e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.161228448380866338e-20 0.000000000000000000e+00 4.594329308297129268e-20 2.334722485957182614e-19 3.028450158909668971e+03 2.295481625143692431e-19 2.261630406416352008e-19 3.292449867314123668e-20 2.005928558171599001e-30 2.190100502301526799e-21 1.550528686504096508e-26 7.728314529010412576e-25 1.171820220033227602e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.161857857098609427e-20 0.000000000000000000e+00 4.657722970696501550e-20 2.335473034821188568e-19 3.031850158731464035e+03 2.301847491041609252e-19 2.264138934297394219e-19 3.329162142792271081e-20 1.995477618041106882e-30 2.189114240362439090e-21 1.545494509308288490e-26 7.711421388946035621e-25 1.171521319346143527e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.150129195704973050e-20 0.000000000000000000e+00 4.721116633103361487e-20 2.339635053214182199e-19 3.035300168022925845e+03 2.342896069984592828e-19 2.266684393849688488e-19 3.415891649770766394e-20 1.984887905310682941e-30 2.188128523422021133e-21 1.540386287271406014e-26 7.694279773287568575e-25 1.171218022228199372e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.174307296033854571e-20 0.000000000000000000e+00 4.785442731864151297e-20 2.344771174864287121e-19 3.038750158371036832e+03 2.319548042023772636e-19 2.269229874127487852e-19 3.479737794501295146e-20 1.974319100166718940e-30 2.187142811893989556e-21 1.535278094505155375e-26 7.677138251750482369e-25 1.170914726775810906e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.177481719222858610e-20 0.000000000000000000e+00 4.849768477422456741e-20 2.349504758712177997e-19 3.042150158194036067e+03 2.469193951861326600e-19 2.271738504112208251e-19 3.335831458699791934e-20 1.964040363859714547e-30 2.186135667349022328e-21 1.530243920904169221e-26 7.660245111680122331e-25 1.170615826089234080e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.183890024523836430e-20 0.000000000000000000e+00 4.913162139851768206e-20 2.351190353292650845e-19 3.045600167454684197e+03 2.571145683388537827e-19 2.274284066900608256e-19 3.060516420816688022e-20 1.953610441126470853e-30 2.185112038227731110e-21 1.525135702598700994e-26 7.643103496174755159e-25 1.170312528974621370e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.181199626369031946e-20 0.000000000000000000e+00 4.977488238038031448e-20 2.351245686101777069e-19 3.049050157836043581e+03 2.436457276382291128e-19 2.276829650114495841e-19 3.163557566107708596e-20 1.943277243374655412e-30 2.184091801504639298e-21 1.520027513506028617e-26 7.625961974472472508e-25 1.170010237013903430e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.174326365253339248e-20 0.000000000000000000e+00 5.041813984216259435e-20 2.356403497954104323e-19 3.052500167076162597e+03 2.358799566054212076e-19 2.279375281483872570e-19 3.429363687778461217e-20 1.933114091154804969e-30 2.183079298792865408e-21 1.514919297762479155e-26 7.608820359069106103e-25 1.169710236609254997e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.184760639903744555e-20 0.000000000000000000e+00 5.111592135388115563e-20 2.364125790219007584e-19 3.056000166884812643e+03 2.323235085293417210e-19 2.281957833874323505e-19 3.541034185673195110e-20 1.922803675051823273e-30 2.182052124935978836e-21 1.509737065382753645e-26 7.591430361983281847e-25 1.169405889204635474e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.180893790033450447e-20 0.000000000000000000e+00 5.192710506997124071e-20 2.370004472225369366e-19 3.059450157299510465e+03 2.310431359299738728e-19 2.284503519982600521e-19 3.598718331622548816e-20 1.912717459187257323e-30 2.181032370911134077e-21 1.504628880114913167e-26 7.574288840115354593e-25 1.169103740266053392e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.198164824785715118e-20 0.000000000000000000e+00 5.272669826942035298e-20 2.375172183287493920e-19 3.062900166508859911e+03 2.297256210125169216e-19 2.287049253855729347e-19 3.203180276281588365e-20 1.902683682403399293e-30 2.180008741805063348e-21 1.499520668330596278e-26 7.557147224864868575e-25 1.168800443156992966e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.208175959478055766e-20 0.000000000000000000e+00 5.352629582484551929e-20 2.373797191772139365e-19 3.066400166318805987e+03 2.356804195588425368e-19 2.289631909909361464e-19 3.434387076292325509e-20 1.892504516289472645e-30 2.178970919455830554e-21 1.494338439960208501e-26 7.539757227772604815e-25 1.168492940648365101e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.192109019141616490e-20 0.000000000000000000e+00 5.433747954123598323e-20 2.381269234096961357e-19 3.069850156766613054e+03 2.329513353843480187e-19 2.292177697879825757e-19 3.534679052152613673e-20 1.882685535263244303e-30 2.177969309325822105e-21 1.489230258638129764e-26 7.522615705740172636e-25 1.168196167672084190e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.199475117556975274e-20 0.000000000000000000e+00 5.513707274835872262e-20 2.387053846626328169e-19 3.073300165945396657e+03 2.311894973956588673e-19 2.294723533229393017e-19 3.548243945446741367e-20 1.872911694826855241e-30 2.176967693757787957e-21 1.484122050934983760e-26 7.505474090641554978e-25 1.167899393084739935e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.218544570572228450e-20 0.000000000000000000e+00 5.593667029669973480e-20 2.391653482384774434e-19 3.076800165756625574e+03 2.325272769857172692e-19 2.297306291908495522e-19 3.507268940106983030e-20 1.862997449094851675e-30 2.175947777440990513e-21 1.478939826699677460e-26 7.488084093542917834e-25 1.167597196060755497e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.223838898479075761e-20 0.000000000000000000e+00 5.674785401338751418e-20 2.395463434553294077e-19 3.080300165568284683e+03 2.343300162737874767e-19 2.299889084894056201e-19 3.295630861195988447e-20 1.853124532959463651e-30 2.174920603583220722e-21 1.473757603885185385e-26 7.470694096442142760e-25 1.167292848657340808e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.210427866669086784e-20 0.000000000000000000e+00 5.755903773017500858e-20 2.396803403383855276e-19 3.083800165380370800e+03 2.322038620259579945e-19 2.302471912070622293e-19 3.473213062755799043e-20 1.843251616822870860e-30 2.173893429725326046e-21 1.468575382506558798e-26 7.453304099339246285e-25 1.166988501254101221e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.225621294008056001e-20 0.000000000000000000e+00 5.837022144706147171e-20 2.403819359674191897e-19 3.087300165192882559e+03 2.337212151087167167e-19 2.305054773323261523e-19 3.599767751020274557e-20 1.833449030170504939e-30 2.172893431575924607e-21 1.463393162579061907e-26 7.435914102234234839e-25 1.166684153851036736e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.216376234771905768e-20 0.000000000000000000e+00 5.925340560372089170e-20 2.410261680290252380e-19 3.090750155706540227e+03 2.295944853351101533e-19 2.307600762931302792e-19 3.398741505706809496e-20 1.823959777912320542e-30 2.171918434256847522e-21 1.458284989572850930e-26 7.418772579874618501e-25 1.166384155077051558e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.242534167879273118e-20 0.000000000000000000e+00 6.044404461847338534e-20 2.412867723705142145e-19 3.094250174382586920e+03 2.314679327006859388e-19 2.310183705430881766e-19 3.259537935943338701e-20 1.814332922419853698e-30 2.170927368727636262e-21 1.453102744644248549e-26 7.401382489044797602e-25 1.166080039950931832e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.239827200724738084e-20 0.000000000000000000e+00 6.165194903779465960e-20 2.416458129613284994e-19 3.097800164632961241e+03 2.366924983973465086e-19 2.312803560395961909e-19 3.278042059769192835e-20 1.804685272128618443e-30 2.169896726396882438e-21 1.447846511659247914e-26 7.383744110906563937e-25 1.165774664854252269e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.232967032993795775e-20 0.000000000000000000e+00 6.287709933236908593e-20 2.422328981335511410e-19 3.101300164447163297e+03 2.316405312832438969e-19 2.315386556813775457e-19 3.578848804832564459e-20 1.795285272627618740e-30 2.168880597418565648e-21 1.442664297693292148e-26 7.366354113793154135e-25 1.165473590004600588e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.205023787752173773e-20 0.000000000000000000e+00 6.408499724220923924e-20 2.432059259727056714e-19 3.104800164261783721e+03 2.355577201813803195e-19 2.317969586740632256e-19 3.189779873482277618e-20 1.785885273125495546e-30 2.167864468440127360e-21 1.437482085258113855e-26 7.348964116677666096e-25 1.165172515155121562e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.196361567876428615e-20 0.000000000000000000e+00 6.529289515219377712e-20 2.432275624513411979e-19 3.108300164076822512e+03 2.377461553082255486e-19 2.320552650064636256e-19 3.543165960264967183e-20 1.776519149188532198e-30 2.166848339461567573e-21 1.432299874370335261e-26 7.331574119560098901e-25 1.164871440305814817e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.222352745343022457e-20 0.000000000000000000e+00 6.650079306232269955e-20 2.443007793243343664e-19 3.111800163892276487e+03 2.491562196727597272e-19 2.323135746674383485e-19 3.522367554188522938e-20 1.767166572362081842e-30 2.165832210482887415e-21 1.427117665046824250e-26 7.314184122440469080e-25 1.164570365456681105e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.194337908988136544e-20 0.000000000000000000e+00 6.770869097259491117e-20 2.448335403587213885e-19 3.115300163708146101e+03 2.361842092405824188e-19 2.325718876458968785e-19 3.228394008212881718e-20 1.757813995534520956e-30 2.164853146208385344e-21 1.421935457304690637e-26 7.296794125318773880e-25 1.164271761584690265e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.211060741546071034e-20 0.000000000000000000e+00 6.891658888301055642e-20 2.450186541144481698e-19 3.118850173007140256e+03 2.386720158248019343e-19 2.328338948874063491e-19 3.476343762654565067e-20 1.748542201830356756e-30 2.163871228742705743e-21 1.416679205612360920e-26 7.279155652536123163e-25 1.163969633539351358e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.211021461621696007e-20 0.000000000000000000e+00 7.014174575152478820e-20 2.459525933258467322e-19 3.122400163335891193e+03 2.363538819729101405e-19 2.330959041188992570e-19 3.354236258102591888e-20 1.739283247462716728e-30 2.162885059467350208e-21 1.411422983671702821e-26 7.261517274008470260e-25 1.163667507108709483e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.228880808058464604e-20 0.000000000000000000e+00 7.136689607314804596e-20 2.463921091635365222e-19 3.125900163153008180e+03 2.326799866801030783e-19 2.333542270774359994e-19 3.399441129983691547e-20 1.730179172966358818e-30 2.161879740370944622e-21 1.406240780825857033e-26 7.244127276880578001e-25 1.163369635184187463e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.195077999715425425e-20 0.000000000000000000e+00 7.332944023355727052e-20 2.472566892835907055e-19 3.129450172421134539e+03 2.382394841475999814e-19 2.336162444053950079e-19 3.268427480850385333e-20 1.721065067539209662e-30 2.160860056857759486e-21 1.401857932784902919e-26 7.228734066343759475e-25 1.163067507142104769e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.177523244875961790e-20 0.000000000000000000e+00 7.532947058766046440e-20 2.479193795386169668e-19 3.133000162783270753e+03 2.366679429769212158e-19 2.338782636940810854e-19 3.540344184864517282e-20 1.711951010650296268e-30 2.159852642662741524e-21 1.397489828577146239e-26 7.213378777377210703e-25 1.162763916366419439e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.180202460434123008e-20 0.000000000000000000e+00 7.732949029036776466e-20 2.491537693082363012e-19 3.136550172030836166e+03 2.387747340779945108e-19 2.341402877215529874e-19 3.517528681301811361e-20 1.702927245821743241e-30 2.158860166959121176e-21 1.393121702167327538e-26 7.198023406722772284e-25 1.162458539637910154e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.198381494175917009e-20 0.000000000000000000e+00 7.932952063288717604e-20 2.500035435523002405e-19 3.140100162415205887e+03 2.426634038162437548e-19 2.344023136903905845e-19 3.618864926412529460e-20 1.694034340616453923e-30 2.157867696529082201e-21 1.388753600013200528e-26 7.182668117660054298e-25 1.162153164532254893e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.188110408573954449e-20 0.000000000000000000e+00 8.132954034812055613e-20 2.510293304775211734e-19 3.143650171642301302e+03 2.430946993424323657e-19 2.346643443725133455e-19 3.323507631409204338e-20 1.685141388209184637e-30 2.156861530164819580e-21 1.384385475729235236e-26 7.167312747094157236e-25 1.161822076101324635e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.211836316039347968e-20 0.000000000000000000e+00 8.332957067910743882e-20 2.515325004355248325e-19 3.147200162048800848e+03 2.404928489830794224e-19 2.349263769768263282e-19 3.682480222802698661e-20 1.676328488841142466e-30 2.155852585522972367e-21 1.380017375668449860e-26 7.151957457935718194e-25 1.161485761674166469e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.197554513652551422e-20 0.000000000000000000e+00 8.532959040680848289e-20 2.529367867451444199e-19 3.150750171255516761e+03 2.403681275855118845e-19 2.351884142691364370e-19 3.449782044143964419e-20 1.667564627728805445e-30 2.154847824971878311e-21 1.375649253550311959e-26 7.136602087457971270e-25 1.161154743860839472e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.210056066907733151e-20 0.000000000000000000e+00 8.732962072631380181e-20 2.535400711847065226e-19 3.154350171060065804e+03 2.421014982470067065e-19 2.354541448830147700e-19 3.435952992275983141e-20 1.658677355484039789e-30 2.153852080345088063e-21 1.371219621422746715e-26 7.121030485386042606e-25 1.160848361312314743e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.232993012149764130e-20 0.000000000000000000e+00 8.935781511682135204e-20 2.544839181295490886e-19 3.157950170865060954e+03 2.420822922785735687e-19 2.357198788680788667e-19 3.503280905663938270e-20 1.649888674619669861e-30 2.152856335718174436e-21 1.366789990422011619e-26 7.105458883312183561e-25 1.160541978763970382e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.225256834878523200e-20 0.000000000000000000e+00 9.138600950758022410e-20 2.555360421103717669e-19 3.161500161315827427e+03 2.424527716212298486e-19 2.359819247028001104e-19 3.592277815007772631e-20 1.641239606975984293e-30 2.151879955850405307e-21 1.362421894702051374e-26 7.090103593962270265e-25 1.160241554595220128e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.207896569663303555e-20 0.000000000000000000e+00 9.430485687568617673e-20 2.569497985354611920e-19 3.165050170481767964e+03 2.439094514620832734e-19 2.362439751752219528e-19 3.646987884509197778e-20 1.632600601633582444e-30 2.150908374394463364e-21 1.358053777071610826e-26 7.074748223660895248e-25 1.159942606859092022e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.216231225180332292e-20 0.000000000000000000e+00 9.744350065902194726e-20 2.584383822185642574e-19 3.168650170288078698e+03 2.474572718651241674e-19 2.365097191131695533e-19 3.498380688553573737e-20 1.623975147552199158e-30 2.149923111289578448e-21 1.353624149485552797e-26 7.059176621581346075e-25 1.159639449390731753e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.227829367833021783e-20 0.000000000000000000e+00 1.006263423036275629e-19 2.596980904315402947e-19 3.172250170094828263e+03 2.420258083084239385e-19 2.367754663773657717e-19 3.827436331679348110e-20 1.615349693469764548e-30 2.148904688499364701e-21 1.349194523070871444e-26 7.043605019499898662e-25 1.159336291922548842e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.219626432761222919e-20 0.000000000000000000e+00 1.038091839486211692e-19 2.616459549728353117e-19 3.175850169902017115e+03 2.454058104438017558e-19 2.370412169566238441e-19 3.622014486750768846e-20 1.606788602429279465e-30 2.147881530659426635e-21 1.344764897839147798e-26 7.028033417416552092e-25 1.159033134454543666e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.241554847651041756e-20 0.000000000000000000e+00 1.069920255940031393e-19 2.628836882892346639e-19 3.179450169709641614e+03 2.467405015747281668e-19 2.373069708398061657e-19 3.545775967215477855e-20 1.598364602879438193e-30 2.146869745703638945e-21 1.340335273802119583e-26 7.012461815331320139e-25 1.158721866826134906e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.256592170082026041e-20 0.000000000000000000e+00 1.101748672397702953e-19 2.643372969828258634e-19 3.183050169517701306e+03 2.477682544157167472e-19 2.375727280158253504e-19 3.415677238496366095e-20 1.589940603328578527e-30 2.145894745755622723e-21 1.335905650971676626e-26 6.996890213244205558e-25 1.158384367301623995e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.217314229399652043e-20 0.000000000000000000e+00 1.133577088859222040e-19 2.657284111135030859e-19 3.186650169326195282e+03 2.490378154628599811e-19 2.378384884736434604e-19 3.567367842438684385e-20 1.581579009195140931e-30 2.144919745807488764e-21 1.331476029359868605e-26 6.981318611155212941e-25 1.158046867777338967e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.224499327658894997e-20 0.000000000000000000e+00 1.165405505324580709e-19 2.675394166552988867e-19 3.190250169135120814e+03 2.437839084709424621e-19 2.381042522022713320e-19 3.537720876057064033e-20 1.573270209636140788e-30 2.143938901078809152e-21 1.327046408978906771e-26 6.965747009064354227e-25 1.157728925761243984e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.239979122537344923e-20 0.000000000000000000e+00 1.197233921793754886e-19 2.691441325472723543e-19 3.193850168944477446e+03 2.491931403289331389e-19 2.383700191907689127e-19 3.500665420554447580e-20 1.564961410076145724e-30 2.142953637973090293e-21 1.322616789841163949e-26 6.950175406971629416e-25 1.157425768294197071e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.244582389473337211e-20 0.000000000000000000e+00 1.229062338266740479e-19 2.707628198603655055e-19 3.197450168754263359e+03 2.536093862797986219e-19 2.386357894282447317e-19 3.869665002823374418e-20 1.556813481772587718e-30 2.141968374867254450e-21 1.318187171959181423e-26 6.934603804877048609e-25 1.157122610827329773e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.256898664893626836e-20 0.000000000000000000e+00 1.285985170572278526e-19 2.741276266556964493e-19 3.201050168564477190e+03 2.514628770895907924e-19 2.389015629038556589e-19 3.827654676043789078e-20 1.548715264377730664e-30 2.140992662680454135e-21 1.313757555345667792e-26 6.919032202780617317e-25 1.156787494559236344e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.235667686415694863e-20 0.000000000000000000e+00 1.358827529005827164e-19 2.777800979122568841e-19 3.204700177863757744e+03 2.526275359012369019e-19 2.391710316732905922e-19 3.555743750135702108e-20 1.540504550389646446e-30 2.140004118495232490e-21 1.309266405908902352e-26 6.903244287377005897e-25 1.156445306652833642e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.291385893304710690e-20 0.000000000000000000e+00 1.432681778917075826e-19 2.813637668324279262e-19 3.208350168180940727e+03 2.555806793155143291e-19 2.394405023477058299e-19 3.689676763053982882e-20 1.532327623274693250e-30 2.139018511621603650e-21 1.304775281159969713e-26 6.887456454079418484e-25 1.156114961968381892e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.272137622363190739e-20 0.000000000000000000e+00 1.506535644744761021e-19 2.855825056449798880e-19 3.211950167992440583e+03 2.572734128402161787e-19 2.397062855620428696e-19 3.568416799591155927e-20 1.524263623696933632e-30 2.138053563218520929e-21 1.300345668466368426e-26 6.871884851977423797e-25 1.155818055171706124e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.293488170667538042e-20 0.000000000000000000e+00 1.579378003204331140e-19 2.895686970430729676e-19 3.215600177260848795e+03 2.577868324638363213e-19 2.399757641700421496e-19 3.389505160299167186e-20 1.516150989526558455e-30 2.137075210218741478e-21 1.295854523084476776e-26 6.856096936707349454e-25 1.155517023889566888e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.318488388714879523e-20 0.000000000000000000e+00 1.653232252490908998e-19 2.936813821006725619e-19 3.219250167611499819e+03 2.613585808360305542e-19 2.402452446545694413e-19 3.693696058762798578e-20 1.508264147631622179e-30 2.136090579605218590e-21 1.291363402352996253e-26 6.840309103264998075e-25 1.155190621822820016e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.339465471577925268e-20 0.000000000000000000e+00 1.727086118995786311e-19 2.984890205428421163e-19 3.222900176859345720e+03 2.652900027656294930e-19 2.405147297965181804e-19 4.011002160737099385e-20 1.500377264903923624e-30 2.135102035433927211e-21 1.286872259756998090e-26 6.824521188083864573e-25 1.154848433922527251e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.566506070544507393e-20 0.000000000000000000e+00 1.800940367866306487e-19 3.035478506455257691e-19 3.226550167232282092e+03 2.893951028674023001e-19 2.407842167961690141e-19 3.414993695546607896e-20 1.492500233764905057e-30 2.134113496374590307e-21 1.282381141787628961e-26 6.808733354545118983e-25 1.154506247792031134e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.415468322971778538e-20 0.000000000000000000e+00 1.874794234822105147e-19 3.102375136215814197e-19 3.230200176459657541e+03 2.742065316597010469e-19 2.410537084282606838e-19 3.648885757876155813e-20 1.484636451508698062e-30 2.133097889026693354e-21 1.277890002035725461e-26 6.792945439452529593e-25 1.154204654611989793e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.509699230154001508e-20 0.000000000000000000e+00 1.948648483278426885e-19 3.140832968375077978e-19 3.233850166854776944e+03 2.708546103255996599e-19 2.413232018994100981e-19 3.435921341687592429e-20 1.476772709825747585e-30 2.132081912318773473e-21 1.273398886887727306e-26 6.777157605817832441e-25 1.153903624887555862e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.719313105362076167e-20 0.000000000000000000e+00 2.185568191467750869e-19 3.278505872191002042e-19 3.237500176061771526e+03 2.735118838369358095e-19 2.415926999782276411e-19 3.674312016678109594e-20 1.469034924042707634e-30 2.131078303323648637e-21 1.268907750039776414e-26 6.761369690813398698e-25 1.153590220679670138e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.452267696733425204e-20 0.000000000000000000e+00 2.639448058596131842e-19 3.600010146020651524e-19 3.241200175860788022e+03 2.765842650647396966e-19 2.418658923817159162e-19 3.522127472386385182e-20 1.461257669563206384e-30 2.130086550800200951e-21 1.264355103993158674e-26 6.745365544239918592e-25 1.153246922198753559e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.544680362306065834e-20 0.000000000000000000e+00 3.099544272582240056e-19 3.950390690267905502e-19 3.244850166289141271e+03 2.798724958478389463e-19 2.421353955228975182e-19 3.928179587015618860e-20 1.453585532819687636e-30 2.129108202850333194e-21 1.259863993212198371e-26 6.729577710461470419e-25 1.152908263756466214e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.327857144968431582e-20 0.000000000000000000e+00 3.553421804580283657e-19 4.319986773404313359e-19 3.248500175465595021e+03 2.860997975909787483e-19 2.424049032348070459e-19 3.598220034855268287e-20 1.446013754330062390e-30 2.128129849875201508e-21 1.255372860856920164e-26 6.713789795589140201e-25 1.152595378544436684e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.288877630236219099e-20 0.000000000000000000e+00 4.007301667910901706e-19 4.699058420560466678e-19 3.252200175265968937e+03 2.940960683271494773e-19 2.426781053729078879e-19 3.630021115772912688e-20 1.438352578272817438e-30 2.127138097351389702e-21 1.250820219373548104e-26 6.697785649009788134e-25 1.152290224339772774e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.305425025496542583e-20 0.000000000000000000e+00 4.467397882065806605e-19 5.098657396450116866e-19 3.255900175066797601e+03 2.958988622985660411e-19 2.429513107634436272e-19 3.788752606827333591e-20 1.430703956726530411e-30 2.126148934931939161e-21 1.246267579458554844e-26 6.681781502428469868e-25 1.151983195997220066e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.335758166443476999e-20 0.000000000000000000e+00 4.927494096277257770e-19 5.508602883532881776e-19 3.259600174868077374e+03 3.039911335349593552e-19 2.432245193954541335e-19 3.694133509086236159e-20 1.423158859092547890e-30 2.125205057431613015e-21 1.241714941129202445e-26 6.665777355845200098e-25 1.151643400563115822e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.326726791069127221e-20 0.000000000000000000e+00 5.387590310544805497e-19 5.924238227768397505e-19 3.263250165351511441e+03 3.293051985978772367e-19 2.434940384960719942e-19 3.961673818760025240e-20 1.415715741243976195e-30 2.124273937410328668e-21 1.237223837979078658e-26 6.649989521828503097e-25 1.151308197815437540e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.350603925326467670e-20 0.000000000000000000e+00 5.841467849392166168e-19 6.342511728248167411e-19 3.266900174477328619e+03 3.314678983526527134e-19 2.437635621066517538e-19 3.811431935716850874e-20 1.408328972788855626e-30 2.123328525138667981e-21 1.232732713468292823e-26 6.634201607175197783e-25 1.150987280831017679e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.318494686654782043e-20 0.000000000000000000e+00 6.295347706426111301e-19 6.762891978429708366e-19 3.270600174279944440e+03 3.626970166384762327e-19 2.440367803112308371e-19 3.577720782812812612e-20 1.400957711046168615e-30 2.122346892537974071e-21 1.228180079957439852e-26 6.618197460586148805e-25 1.150685240445741883e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.302087253214374745e-20 0.000000000000000000e+00 6.761190456778572837e-19 7.198237938744292897e-19 3.274350183624225792e+03 3.694245305618224736e-19 2.443136946219567992e-19 3.583452857518644552e-20 1.393486818643775366e-30 2.121351992099695169e-21 1.223683163679848067e-26 6.602293381883619860e-25 1.150379117654731926e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.314623366266964045e-20 0.000000000000000000e+00 7.252844990031908171e-19 7.662829413987266888e-19 3.278100173881207411e+03 3.965201907381368268e-19 2.445906107974470484e-19 3.329827311981451977e-20 1.386040832117608728e-30 2.120364600798874740e-21 1.219847103805683225e-26 6.588172549751089644e-25 1.150047020818851576e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.329304009157669887e-20 0.000000000000000000e+00 7.744497020796161309e-19 8.129503099228987137e-19 3.281800173685168375e+03 4.435070066934593976e-19 2.448638386508741974e-19 3.632689444688692998e-20 1.378713381525450675e-30 2.119392883678642643e-21 1.216062182782063697e-26 6.574239959919727894e-25 1.149710657663169068e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.348015032780759033e-20 0.000000000000000000e+00 8.229594925799508334e-19 8.594927558045682579e-19 3.285500173489571353e+03 5.023846366129855852e-19 2.451370696704145228e-19 4.096862459076213202e-20 1.371385930932417161e-30 2.118420362135419990e-21 1.212277262779446104e-26 6.560307370086702085e-25 1.149374016054029046e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.314162756867984106e-20 0.000000000000000000e+00 8.714692830860806591e-19 9.063155265309469361e-19 3.289200173294413617e+03 5.798434731188923463e-19 2.454103038454927916e-19 3.474476375948289249e-20 1.364253514228392076e-30 2.117438729534135136e-21 1.208492343807430125e-26 6.546374780252021401e-25 1.149034220621716067e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.332530673694077232e-20 0.000000000000000000e+00 9.199790735979698821e-19 9.528789426400889375e-19 3.292900173099694712e+03 7.091830669058143829e-19 2.456835411655807632e-19 3.690780953776793308e-20 1.357166591524430774e-30 2.116457096932734049e-21 1.204707425875734969e-26 6.532442190415688596e-25 1.148694425189639692e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.355758336261500242e-20 0.000000000000000000e+00 9.684888641156124355e-19 9.999414361236719746e-19 3.296650182382110415e+03 9.117265682420158423e-19 2.459604747802306881e-19 3.532811465140724037e-20 1.349984507311712190e-30 2.115466618768334527e-21 1.200871351779139137e-26 6.518321286641648652e-25 1.148351567836411974e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.324608247577581122e-20 0.000000000000000000e+00 1.017654316629840573e-18 1.047638387806596987e-18 3.300400172706334160e+03 1.162674690832836132e-18 2.462374102037542207e-19 3.859274478201782836e-20 1.342848603393771864e-30 2.114481772824598984e-21 1.197035298165405807e-26 6.504200454255914197e-25 1.148010660095620173e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.395560328842338403e-20 0.000000000000000000e+00 1.066819520587861089e-18 1.095639858469098442e-18 3.304100172512934023e+03 1.304129714779063081e-18 2.465106569801782489e-19 3.924918560754424317e-20 1.335807827062766422e-30 2.113510055703673627e-21 1.193250383443290213e-26 6.490267864414614929e-25 1.147674296941341675e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.315039972776772921e-20 0.000000000000000000e+00 1.115329311122793679e-18 1.142998771617786549e-18 3.307850181764585614e+03 1.148998889433405090e-18 2.467876001445205067e-19 3.754286533353915487e-20 1.328711200099771609e-30 2.112525204789098604e-21 1.189414312663670677e-26 6.476146960756419953e-25 1.147363187255048877e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.314623476738751177e-20 0.000000000000000000e+00 1.158213943770077135e-18 1.184884689984634143e-18 3.311600172122232834e+03 8.870933992063001458e-19 2.470645450902717926e-19 3.760399948219669563e-20 1.321730448818613034e-30 2.111540358836585409e-21 1.185578262333026632e-26 6.462026128244826788e-25 1.147060158150129297e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.304528800115523175e-20 0.000000000000000000e+00 1.089849744442191376e-18 1.118214366553915370e-18 3.315350181353396692e+03 6.910296477312561724e-19 2.473414945959747521e-19 3.850672243037866378e-20 1.314749662403677220e-30 2.110562454661650824e-21 1.181742193828015928e-26 6.447905224663779139e-25 1.146752070304755993e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.329852132690211323e-20 0.000000000000000000e+00 1.021485201040660047e-18 1.051796186887204040e-18 3.319100171733296975e+03 5.612108720113668856e-19 2.476184458649170833e-19 3.747322143776672540e-20 1.307855688590288576e-30 2.109624957066675672e-21 1.177906145750230483e-26 6.433784392068390675e-25 1.146414571637660630e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.309916080987018541e-20 0.000000000000000000e+00 9.531210013070898565e-19 9.855638655045530170e-19 3.322850180944064505e+03 5.002483170704296967e-19 2.478954016694934780e-19 3.865845866162429883e-20 1.301055671888096767e-30 2.108687454763983695e-21 1.174070079563987279e-26 6.419663488564146888e-25 1.146077071276064393e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.304077345169170916e-20 0.000000000000000000e+00 8.847564582773937772e-19 9.197371466275544300e-19 3.326650180737373830e+03 4.416506913973807135e-19 2.481760527108247708e-19 3.842084786465838064e-20 1.294165005596229002e-30 2.107714093947760446e-21 1.170182876777178748e-26 6.405354342271014682e-25 1.145733389788393620e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.337891067285893618e-20 0.000000000000000000e+00 8.154805619311655822e-19 8.533819848064756464e-19 3.330400171150608458e+03 4.063241390057594188e-19 2.484530134269287024e-19 3.921506339393749699e-20 1.287379690612361724e-30 2.106729247980648176e-21 1.166346832178929906e-26 6.391233509550103625e-25 1.145392482041663221e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.347341751714334961e-20 0.000000000000000000e+00 7.471163615898936201e-19 7.884395107078886833e-19 3.334150180330814237e+03 3.957619253509027388e-19 2.487299786424097664e-19 3.645859308045201951e-20 1.280600827863528044e-30 2.105744397084836675e-21 1.162510769572272483e-26 6.377112606160941654e-25 1.145051572589128395e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.345888673651237098e-20 0.000000000000000000e+00 6.787518191173534736e-19 7.239383607567283787e-19 3.337950180125521456e+03 3.541481205997569911e-19 2.490106391904147616e-19 3.750265020176707201e-20 1.273731597465403078e-30 2.104763319967687606e-21 1.158623570415492674e-26 6.362803459862545436e-25 1.144711969443059808e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.336048342707969711e-20 0.000000000000000000e+00 6.094759227456410848e-19 6.595891831441462204e-19 3.341750179920695700e+03 3.347082184521355515e-19 2.492913029139092270e-19 3.832772311130061759e-20 1.267018158844639254e-30 2.103785102198632734e-21 1.154736372503963881e-26 6.348494313562390569e-25 1.144373356070236422e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.331955462248396006e-20 0.000000000000000000e+00 5.402000263654146411e-19 5.963341199281527167e-19 3.345500170378115854e+03 3.208277924793768470e-19 2.495682761063864794e-19 3.762055614174390025e-20 1.260403889961646839e-30 2.102824957405471146e-21 1.150900332721724865e-26 6.334373480675096553e-25 1.144038575055786959e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.366788976241651935e-20 0.000000000000000000e+00 4.718358252186184353e-19 5.352767681778128787e-19 3.349250179517797733e+03 3.139868709578758828e-19 2.498452537504947498e-19 3.775827301250754366e-20 1.253804259580511022e-30 2.101887455120550763e-21 1.147064275066283225e-26 6.320252577438530278e-25 1.143701074702532219e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.359623370163627975e-20 0.000000000000000000e+00 4.377970275849556508e-19 5.056729762594100935e-19 3.353050179314350771e+03 3.080101103488638752e-19 2.501259268537817862e-19 3.763188119980569858e-20 1.247203117076784620e-30 2.100937455171412368e-21 1.143177080932995600e-26 6.305943431133183032e-25 1.143359075196697963e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.361675052025853577e-20 0.000000000000000000e+00 4.085197395715216937e-19 4.806856067014881291e-19 3.356850179111364923e+03 3.006354552724479168e-19 2.504066030902697822e-19 3.704962632905246944e-20 1.240601974572257201e-30 2.099972231119846722e-21 1.139289888096147092e-26 6.291634284826100096e-25 1.143018902580840219e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.357105049943925613e-20 0.000000000000000000e+00 3.792424515545351180e-19 4.561697803790400688e-19 3.360650178908837461e+03 2.957389379345962070e-19 2.506872824494345418e-19 3.982876456618458934e-20 1.234062904414837441e-30 2.098994013350200529e-21 1.135402696569061452e-26 6.277325138517290651e-25 1.142680289209206622e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.444766572648152648e-20 0.000000000000000000e+00 3.499651635340168683e-19 4.325742783564367757e-19 3.364450178706767474e+03 2.902928538654376590e-19 2.509679649207991024e-19 3.704230387251463487e-20 1.227624414191175069e-30 2.098015795580436222e-21 1.131515506365242230e-26 6.263015992206759292e-25 1.142341675837811696e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.360689738732892566e-20 0.000000000000000000e+00 3.206878755099739742e-19 4.091315429827627832e-19 3.368250178505153599e+03 2.916383119185905228e-19 2.512486504939330609e-19 3.746762579949396401e-20 1.221185923966740056e-30 2.097070747894763820e-21 1.127628317498380949e-26 6.248706845894509690e-25 1.142003062466656196e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.348478760536857047e-20 0.000000000000000000e+00 2.914105874824169321e-19 3.868299099459472636e-19 3.372100187815698064e+03 2.876549659284855698e-19 2.515330331536989587e-19 3.486386254712871052e-20 1.214714780368474821e-30 2.096117775293144038e-21 1.123689973054622733e-26 6.234209385512669830e-25 1.141659992808838600e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.307708481824088316e-20 0.000000000000000000e+00 2.617479986734758721e-19 3.649288666764718058e-19 3.375950178098012657e+03 2.788803919123175086e-19 2.518174175704160187e-19 3.741517528083029807e-20 1.208278758877662225e-30 2.095155399697541181e-21 1.119751649477411417e-26 6.219711996782865882e-25 1.141316924846891657e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.325071342168687826e-20 0.000000000000000000e+00 2.320855564684811945e-19 3.447562709240479777e-19 3.379750177897768936e+03 2.817936948305267615e-19 2.520981124674097870e-19 3.807143490292050796e-20 1.201926306382220443e-30 2.094177181927307053e-21 1.115864464741971682e-26 6.205402850465456962e-25 1.140978311476462330e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.349191519974044904e-20 0.000000000000000000e+00 2.028082684303677451e-19 3.260702461044873435e-19 3.383550177697975414e+03 2.804460573081153848e-19 2.523788104246443182e-19 3.576739673347190568e-20 1.195645178664093592e-30 2.093198964156956691e-21 1.111977281400565075e-26 6.191093704146352759e-25 1.140639698106274120e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.339658558607830354e-20 0.000000000000000000e+00 1.735309803887857441e-19 3.086624739447836538e-19 3.387400186967383434e+03 2.773289477301504795e-19 2.526632055861526566e-19 3.576714272536126201e-20 1.189296295453786608e-30 2.092230646790251702e-21 1.108038942657962353e-26 6.176596243919414585e-25 1.140296628453267587e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.312841515554449826e-20 0.000000000000000000e+00 1.599642227984360971e-19 3.014706777145543461e-19 3.391250177294503828e+03 2.765621958839995501e-19 2.529476024686507598e-19 3.940384255002459719e-20 1.182957845844349048e-30 2.091277678887498871e-21 1.104100624754206362e-26 6.162098855020892300e-25 1.139953560488474444e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.335741309278437703e-20 0.000000000000000000e+00 1.538879948415117801e-19 2.989995999663682948e-19 3.395050177096061816e+03 2.724620852488540437e-19 2.532283096251854373e-19 3.461782178634205052e-20 1.176849434948386494e-30 2.090337084877212312e-21 1.100213445721860854e-26 6.147789708696699492e-25 1.139614947119017298e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.317217646743299114e-20 0.000000000000000000e+00 1.478906641812543756e-19 2.955905840811842867e-19 3.398900186334789851e+03 2.678846267080707041e-19 2.535127140734942155e-19 3.616184184446446025e-20 1.170660635050617975e-30 2.089393091584610131e-21 1.096275111424408817e-26 6.133292248585288535e-25 1.139275110009923755e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.326519095506343520e-20 0.000000000000000000e+00 1.418144063771799972e-19 2.930346902012170548e-19 3.402750176695315531e+03 2.682576881216718420e-19 2.537971202162189218e-19 3.807214247406000733e-20 1.164499346758435451e-30 2.088449466496246089e-21 1.092336797947797584e-26 6.118794859560976417e-25 1.138935405454454239e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.322371510786556381e-20 0.000000000000000000e+00 1.357381783675339258e-19 2.906335231280243496e-19 3.406600185913613586e+03 2.718202419760707323e-19 2.540815308306149582e-19 3.650506281474113909e-20 1.158411294798285685e-30 2.087497040448990798e-21 1.088398466706733886e-26 6.104297399526496055e-25 1.138596727377180019e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.341201689268832700e-20 0.000000000000000000e+00 1.296619205957030573e-19 2.879024032841811835e-19 3.410500185701016562e+03 2.710940101711339659e-19 2.543696375120903844e-19 3.756745519260714345e-20 1.152244192330729008e-30 2.086512574483238416e-21 1.084408999649221869e-26 6.089611696753724041e-25 1.138255951175141768e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.342634934637419466e-20 0.000000000000000000e+00 1.235067654584844847e-19 2.855784713702585634e-19 3.414350176095006645e+03 2.687778309590631442e-19 2.546540529017899475e-19 3.595492860303397223e-20 1.146192622027241991e-30 2.085540732247862396e-21 1.080470690786651965e-26 6.075114307603399846e-25 1.137919544720072373e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.349256344425115331e-20 0.000000000000000000e+00 1.174305373960234198e-19 2.830531191719642663e-19 3.418200185282697475e+03 2.669200614082746030e-19 2.549384727274979144e-19 3.738564398309075233e-20 1.140176532904046630e-30 2.084587209489534872e-21 1.076532364276023052e-26 6.060616847684173032e-25 1.137580994834052619e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.340192792740495211e-20 0.000000000000000000e+00 1.113542796724982206e-19 2.810272907048941674e-19 3.422100185071539727e+03 2.691167645605390517e-19 2.552265887108468787e-19 3.707324633346590665e-20 1.134082327626528490e-30 2.083631327188348300e-21 1.072542902029766221e-26 6.045931144905981805e-25 1.137236877689594721e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.408107212628147437e-20 0.000000000000000000e+00 1.051991245330081340e-19 2.789010656146795574e-19 3.425950175498762746e+03 2.644391958002875540e-19 2.555110132545951306e-19 3.975555228562497134e-20 1.128130196988821503e-30 2.082687821480883173e-21 1.068604597936892211e-26 6.031433755630516135e-25 1.136897216112897607e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.351367028766385536e-20 0.000000000000000000e+00 1.010481351283061916e-19 2.779664671389027221e-19 3.429800184656048714e+03 2.662864883707205072e-19 2.557954421991332685e-19 3.931968287955990333e-20 1.122200463258721454e-30 2.081753353238823224e-21 1.064873046553284247e-26 6.017520369557142213e-25 1.136560808019449764e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.346622453449869194e-20 0.000000000000000000e+00 9.878465707252021175e-20 2.773494525965473698e-19 3.433700184446316598e+03 2.728938987531795997e-19 2.560835673910762428e-19 3.693993341120191192e-20 1.116193734609785590e-30 2.080806751347981316e-21 1.061556533581408867e-26 6.004735565815451496e-25 1.136220031818876838e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.339602147518606250e-20 0.000000000000000000e+00 9.649178877475642648e-20 2.764762044255121896e-19 3.437600184237059693e+03 2.671547196771499144e-19 2.563716956582768411e-19 3.711348306957518604e-20 1.110339723644410665e-30 2.079860149457024305e-21 1.058240021629617211e-26 5.991950762072203249e-25 1.135879255618550482e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.370757408777914546e-20 0.000000000000000000e+00 9.419892047671324896e-20 2.759905926057800634e-19 3.441500184028277545e+03 2.666328564102212839e-19 2.566598269903783270e-19 3.658885895919360608e-20 1.104489723957583787e-30 2.078913547565951813e-21 1.054923510707534500e-26 5.979165958327398391e-25 1.135538479418471075e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.348408938093335163e-20 0.000000000000000000e+00 9.190605217839096808e-20 2.754036416129077617e-19 3.445400183819967879e+03 2.686469077342245368e-19 2.569479613770700418e-19 3.852552809422495912e-20 1.098665418245918622e-30 2.077966945674764968e-21 1.051607000824908927e-26 5.966381154581044267e-25 1.135197703218639180e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.340796378379384975e-20 0.000000000000000000e+00 8.961318387979089588e-20 2.751769867003429997e-19 3.449300183612129331e+03 2.714791520852211545e-19 2.572360988080874530e-19 3.982972276328473385e-20 1.092940647908800927e-30 2.076993157534802073e-21 1.048290491991610657e-26 5.953596350833145471e-25 1.134829740808801295e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.331998110586929024e-20 0.000000000000000000e+00 8.732031558091385088e-20 2.748903026566905839e-19 3.453200183404760082e+03 2.688130992503124669e-19 2.575242392732118653e-19 3.786504992874745561e-20 1.087215877570994319e-30 2.076008691567730505e-21 1.044973984217636413e-26 5.940811547083709348e-25 1.134451100587359977e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.360691849455194908e-20 0.000000000000000000e+00 8.502744728176089234e-20 2.741767817180425515e-19 3.457100183197858769e+03 2.666512417052921127e-19 2.578123827622703722e-19 3.669017896455788095e-20 1.081504917852013536e-30 2.075027840577437741e-21 1.041657477513109050e-26 5.928026743332738655e-25 1.134075626969420539e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.368413326930288027e-20 0.000000000000000000e+00 8.273457898233283878e-20 2.735895682754460955e-19 3.461000182991424026e+03 2.679004443125131388e-19 2.581005292651349416e-19 3.873718985976325063e-20 1.075813807042144345e-30 2.074090340627061552e-21 1.038340971888281859e-26 5.915241939580237981e-25 1.133738127464884004e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.373717791295605312e-20 0.000000000000000000e+00 8.044171068263047262e-20 2.734622810790678441e-19 3.464900182785453126e+03 2.647679036891741042e-19 2.583886787717231374e-19 3.626261144275359675e-20 1.070122696231598151e-30 2.073152840676573644e-21 1.035024467353539280e-26 5.902457135826217431e-25 1.133400627960591785e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.351500313608650374e-20 0.000000000000000000e+00 7.837391693639438024e-20 2.727826882919788235e-19 3.468850192066529871e+03 2.680778649443012165e-19 2.586805262553305860e-19 3.754637532754240708e-20 1.064448900837381442e-30 2.072203319214776411e-21 1.031665436582303183e-26 5.889508393223091862e-25 1.133058800718646023e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.376165762209388954e-20 0.000000000000000000e+00 7.678883021640627747e-20 2.727944839612272652e-19 3.472800182369649065e+03 2.641274261174226674e-19 2.589723753972609762e-19 4.035470804760815251e-20 1.058824694460829960e-30 2.071253802314988117e-21 1.028306423090119879e-26 5.876559712832652163e-25 1.132716975119313498e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.391041129786373885e-20 0.000000000000000000e+00 7.520375111202267302e-20 2.730382217652083666e-19 3.476700182165075148e+03 2.669537880677144709e-19 2.592605339310899630e-19 3.873534075465477403e-20 1.053271667229177211e-30 2.070316302364164676e-21 1.024989921918193284e-26 5.863774909074051776e-25 1.132379475615762498e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.376025114515280763e-20 0.000000000000000000e+00 7.363873254021792850e-20 2.726426727651653880e-19 3.480650191415391419e+03 2.677954803898473149e-19 2.595523905246357566e-19 3.578036102047909900e-20 1.047710740139101063e-30 2.069373763948716477e-21 1.021630894613541829e-26 5.850826166571763419e-25 1.132011112867000675e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.584451402556259090e-20 0.000000000000000000e+00 7.205364583257360426e-20 2.722058374127161274e-19 3.484600181752085518e+03 2.647726382309274983e-19 2.598442487504758374e-19 3.784306982017948081e-20 1.042159010601655819e-30 2.068433290059027367e-21 1.018271884567153906e-26 5.837877486071259796e-25 1.131634923845435776e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.400739417463171168e-20 0.000000000000000000e+00 7.046856671471683189e-20 2.722475280745838955e-19 3.488550190981921332e+03 2.638507338966616415e-19 2.601361113918916018e-19 3.948625276975156503e-20 1.036622829090238508e-30 2.067491781013961329e-21 1.014912859640409571e-26 5.824928743636109616e-25 1.131262649515951543e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.407569573083453678e-20 0.000000000000000000e+00 6.888348001529104054e-20 2.723574377816796944e-19 3.492500181340963991e+03 2.626933031599903978e-19 2.604279756483875471e-19 3.976266271354047948e-20 1.031207751398023770e-30 2.066542264100729894e-21 1.011553851958973076e-26 5.811980063062344225e-25 1.130920823913319734e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.440241270225005279e-20 0.000000000000000000e+00 6.729840088846609112e-20 2.722973626008076169e-19 3.496450190550410298e+03 2.638484639029209377e-19 2.607198442970708271e-19 4.003196082502545135e-20 1.025792647863619242e-30 2.065592742656151678e-21 1.008194829457323379e-26 5.799031320694033756e-25 1.130578996679699294e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.405389688399598389e-20 0.000000000000000000e+00 6.571331419722233628e-20 2.722107486136003437e-19 3.500400180931698287e+03 2.666581373471658332e-19 2.610117145437875932e-19 3.777325789341214884e-20 1.020405937724872387e-30 2.064647575968643247e-21 1.004835824188820206e-26 5.786082640047345471e-25 1.130238737156685581e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.409959380897086885e-20 0.000000000000000000e+00 6.412823506147062935e-20 2.717916544491347463e-19 3.504350190120844672e+03 2.635227818662434488e-19 2.613035891594981049e-19 3.790265836307038194e-20 1.015077016236969575e-30 2.063707097590274979e-21 1.001476804160724873e-26 5.773133897745580839e-25 1.129900165422848640e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.411447397619643524e-20 0.000000000000000000e+00 6.260536338945284443e-20 2.717358325305579377e-19 3.508350189904081162e+03 2.626510751913096700e-19 2.615991607128325599e-19 3.831122311607228590e-20 1.009680652893039652e-30 2.062754716689504483e-21 9.980752742598872396e-27 5.760021278528755305e-25 1.129557308787346364e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.403660078144058743e-20 0.000000000000000000e+00 6.149015129751864444e-20 2.718188117615557834e-19 3.512300180318684852e+03 2.628131342010845260e-19 2.618910399072581659e-19 3.631403491906886718e-20 1.004391760012223031e-30 2.061821655585215804e-21 9.947162727194920945e-27 5.747072597772851657e-25 1.129190273536784132e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.411644983937880909e-20 0.000000000000000000e+00 6.038888196949233829e-20 2.715828479800317957e-19 3.516250189477421372e+03 2.616430436722551739e-19 2.621829234361022119e-19 3.769723094934352256e-20 9.991346569136864062e-31 2.060890049651551454e-21 9.913572565117691857e-27 5.734123855570776292e-25 1.128817631695237410e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.418976714185012221e-20 0.000000000000000000e+00 5.928760741554486435e-20 2.718140135179203010e-19 3.520250189262121239e+03 2.630210972522298147e-19 2.624785039874139153e-19 3.769454249221645928e-20 9.938110208365949419e-31 2.059945193032828293e-21 9.879557304915309865e-27 5.721011236349153272e-25 1.128445881857430836e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.408953303824894380e-20 0.000000000000000000e+00 5.817239532320266814e-20 2.718527227611988557e-19 3.524250189047309959e+03 2.603535579925115915e-19 2.627740875429783464e-19 4.183533294500804365e-20 9.885819162303461115e-31 2.058992812131592865e-21 9.845542058026075813e-27 5.707898617125926804e-25 1.128103025223022051e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.398999126271777461e-20 0.000000000000000000e+00 5.705718323072418831e-20 2.725016885242762671e-19 3.528250188832986169e+03 2.611373415700995220e-19 2.630696740926686284e-19 3.683718781681538882e-20 9.833783129055565242e-31 2.058040431230241580e-21 9.811526824588513502e-27 5.694785997901103317e-25 1.127760168588869619e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.397566029968536616e-20 0.000000000000000000e+00 5.594197113810978597e-20 2.718326000001514966e-19 3.532250188619147139e+03 2.666045709743409974e-19 2.633652636264035774e-19 3.932093506810025163e-20 9.781756138795803777e-31 2.057113164840947940e-21 9.777511604743081020e-27 5.681673378674690158e-25 1.127398765880224569e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.388629960657544459e-20 0.000000000000000000e+00 5.482675904536023150e-20 2.722346480275601355e-19 3.536250188405792414e+03 2.650319079991771559e-19 2.636608561341469316e-19 3.769632838785977081e-20 9.730440826217581756e-31 2.056207504511896089e-21 9.743496398632176477e-27 5.668560759446689163e-25 1.127021407950152869e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.359614718016774562e-20 0.000000000000000000e+00 5.371154695247565730e-20 2.720539356310922022e-19 3.540250188192919268e+03 2.599266022587861100e-19 2.639564516059073036e-19 3.672033210306232564e-20 9.679125513633181761e-31 2.055301844182735151e-21 9.709481206400215496e-27 5.655448140217110434e-25 1.126644050020397894e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.427062439169384813e-20 0.000000000000000000e+00 5.259633485945680967e-20 2.720237303768254988e-19 3.544250187980527244e+03 2.687250495404152447e-19 2.642520500317379875e-19 3.845948788555347986e-20 9.628015647092452765e-31 2.054362691514026617e-21 9.675466028193621165e-27 5.642335520985953971e-25 1.126266692090960021e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.406095021765202966e-20 0.000000000000000000e+00 5.148112276630383307e-20 2.723266115526467466e-19 3.548250187768613614e+03 2.626807983108142527e-19 2.645476514017365736e-19 3.876519342776153339e-20 9.577565199314785938e-31 2.053419295337591127e-21 9.641450864160911573e-27 5.629222901753228958e-25 1.125889334161839813e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.362377897872256266e-20 0.000000000000000000e+00 5.076486180910398760e-20 2.725002069535676595e-19 3.552250187557177469e+03 2.649129577771130938e-19 2.648432557060447563e-19 3.753074188110191057e-20 9.527114751531095279e-31 2.052477993561407382e-21 9.607435714452678277e-27 5.616110282518939068e-25 1.125521694236768920e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.379482438438209645e-20 0.000000000000000000e+00 5.007020542976826259e-20 2.724946032419948759e-19 3.556250187346216535e+03 2.639749077369243949e-19 2.651388629348480446e-19 3.587590907661246896e-20 9.477203048769831090e-31 2.051543414171444689e-21 9.573420579221679581e-27 5.602997663283090729e-25 1.125185246139758357e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.383060883797330464e-20 0.000000000000000000e+00 4.937554905035001149e-20 2.724342176523397660e-19 3.560300196612639866e+03 2.651782168186769558e-19 2.654381689241387908e-19 4.003112538543599834e-20 9.427301148879972126e-31 2.050597150324149431e-21 9.538980189096708246e-27 5.589721105229816028e-25 1.124844591644446313e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.397480773836418604e-20 0.000000000000000000e+00 4.867220781984963499e-20 2.731843000817357135e-19 3.564350186920471515e+03 2.639595167807132933e-19 2.657374764902501566e-19 3.616630415274958289e-20 9.377399482587045358e-31 2.049650890906431731e-21 9.504539975358892988e-27 5.576444609325743153e-25 1.124481974411938073e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.419335118688350328e-20 0.000000000000000000e+00 4.796886988177609713e-20 2.728229044488766156e-19 3.568350186710940307e+03 2.660925584757546904e-19 2.660330925063467648e-19 3.768678658134059162e-20 9.328604875652867205e-31 2.048716311516135385e-21 9.470524884873797047e-27 5.563331990085208450e-25 1.124108143193915484e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.431935878372937820e-20 0.000000000000000000e+00 4.727421350210955152e-20 2.732018600732623687e-19 3.572400195946697295e+03 2.672643048368688179e-19 2.663324073605750336e-19 3.980588370216928063e-20 9.279426192075817972e-31 2.047770047676005188e-21 9.436084540818627543e-27 5.550055432132462392e-25 1.123729638203051855e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.421287718682901431e-20 0.000000000000000000e+00 4.657087227693481669e-20 2.736672573420657047e-19 3.576450186288074292e+03 2.710563545086591566e-19 2.666317237664327103e-19 3.846581095192086021e-20 9.230247737930528673e-31 2.046858836720431854e-21 9.401644373105967718e-27 5.536778936118422021e-25 1.123351134978382970e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.450031637432660566e-20 0.000000000000000000e+00 4.586753433303565371e-20 2.736633628397716456e-19 3.580500195503415853e+03 2.692249905335584988e-19 2.669310445052895611e-19 4.135782814586277520e-20 9.181990595074416846e-31 2.045950423438486215e-21 9.367204060735516626e-27 5.523502378232601082e-25 1.122972629990162228e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.445561144085732345e-20 0.000000000000000000e+00 4.516419311140634526e-20 2.742569388222093468e-19 3.584550185867119581e+03 2.698111949200228140e-19 2.672303667791173443e-19 3.822906543192883606e-20 9.133820798182223619e-31 2.045033753271500309e-21 9.332763924692172678e-27 5.510225882145370575e-25 1.122605771931342682e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.453797283310237411e-20 0.000000000000000000e+00 4.446085516362982790e-20 2.739837460064966634e-19 3.588600195062136208e+03 2.678867159428582758e-19 2.675296933631178910e-19 4.017343418080372423e-20 9.085704843910537141e-31 2.044096251143024118e-21 9.298323644707240975e-27 5.496949324326178125e-25 1.122268271652502188e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.445079455882877487e-20 0.000000000000000000e+00 4.387139719770755202e-20 2.744540114776307657e-19 3.592700194839530468e+03 2.696846611931240801e-19 2.678327175952848636e-19 4.131537109084266423e-20 9.037383417962677201e-31 2.043147177120478756e-21 9.266270737352529179e-27 5.484340686298106512e-25 1.121926605498111706e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.446326480744072042e-20 0.000000000000000000e+00 4.331194623996652577e-20 2.748306176335342425e-19 3.596750185236667221e+03 2.699364223522129064e-19 2.681320486331857997e-19 3.863708187043996554e-20 8.989651388282137629e-31 2.042209679343364046e-21 9.237641199059477179e-27 5.472782683201122520e-25 1.121565493994237002e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.449496622197228018e-20 0.000000000000000000e+00 4.275931913520113583e-20 2.746479775061261864e-19 3.600800194401238969e+03 2.698359565732943645e-19 2.684313839472356839e-19 4.110883223293537168e-20 8.942288022130836216e-31 2.041272177221935555e-21 9.209011538057283056e-27 5.461224626544981055e-25 1.121190493688256457e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.580165124675492342e-20 0.000000000000000000e+00 4.220668946959183740e-20 2.752850607170928523e-19 3.604900194180138897e+03 2.905754962625049503e-19 2.687344169898434877e-19 4.007732881567039556e-20 8.894974750346006994e-31 2.040323103199041870e-21 9.180028501836623892e-27 5.449523904939403923e-25 1.120810864628756944e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.456104809193343105e-20 0.000000000000000000e+00 4.164723851164535654e-20 2.752749805062361257e-19 3.609000193959540411e+03 2.981847883381942964e-19 2.690374529734563834e-19 3.962668550015034069e-20 8.847661478555390409e-31 2.039411068008991100e-21 9.151045476011751502e-27 5.437823183332395993e-25 1.120431235569583560e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.435148076346273082e-20 0.000000000000000000e+00 4.108778755363043897e-20 2.754106228094381887e-19 3.613100193739443057e+03 2.747061518497239031e-19 2.693404918881479356e-19 3.777932318338753132e-20 8.801039923145219143e-31 2.038499956946790401e-21 9.122062460681785086e-27 5.426122461723957267e-25 1.120051606510736870e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.440921558182378033e-20 0.000000000000000000e+00 4.052833659554713885e-20 2.753673172139351322e-19 3.617200193519844561e+03 2.849595529116701186e-19 2.696435337240354755e-19 4.133040277095696802e-20 8.754860978250171439e-31 2.037575881129665681e-21 9.093079455947133844e-27 5.414421740114094171e-25 1.119671977452217061e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.427703941899825029e-20 0.000000000000000000e+00 3.996888563739576914e-20 2.760843866051883858e-19 3.621250183983426723e+03 3.425616386604950489e-18 2.699428820972606818e-19 4.247629791102962103e-20 8.709245296186667245e-31 2.036638383337169863e-21 9.064449978874622586e-27 5.402863736827486410e-25 1.119296978879644184e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.438093438243186891e-20 0.000000000000000000e+00 3.941625852356381121e-20 2.764764888934206591e-19 3.625300193087463413e+03 2.739136970315000501e-19 2.702422346795772778e-19 4.256201857961598833e-20 8.664208385416195494e-31 2.035700881229754017e-21 9.035820380572684422e-27 5.391305680344103125e-25 1.118921978581470614e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.449757050896129733e-20 0.000000000000000000e+00 3.886362886621460363e-20 2.767098626617041876e-19 3.629450202395215001e+03 2.726958246221904458e-19 2.705489816093381828e-19 4.206189626030398343e-20 8.618194247126738821e-31 2.034772432500136156e-21 9.006483889797091758e-27 5.379462239810165657e-25 1.118540140186394878e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.448886909263146889e-20 0.000000000000000000e+00 3.835785740014716804e-20 2.768620568983094769e-19 3.633600192646405958e+03 2.723530027180220961e-19 2.708557300834464581e-19 3.976902430871016794e-20 8.572208417344609912e-31 2.033858673178773250e-21 8.977147545015011824e-27 5.367618853660502798e-25 1.118159407689698999e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.445635151575189645e-20 0.000000000000000000e+00 3.789843355689433997e-20 2.767581363583888720e-19 3.637700192429277195e+03 2.809147099587698115e-19 2.711587863786218710e-19 4.067002015879571933e-20 8.527324209195283614e-31 2.032954084305211741e-21 8.948164594808577517e-27 5.355918132043592247e-25 1.117785098093316176e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.417693864071406037e-20 0.000000000000000000e+00 3.744454389846877634e-20 2.771093642826821605e-19 3.641800192212637285e+03 2.734994557573736445e-19 2.714618455366211276e-19 4.125934475388151406e-20 8.482440001040604356e-31 2.032013717382422554e-21 8.919181655827550333e-27 5.344217410425286715e-25 1.117446566494239352e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.455135997072473830e-20 0.000000000000000000e+00 3.699065423998910009e-20 2.774514290044841385e-19 3.645900191996484409e+03 2.757763875403558289e-19 2.717649075478665301e-19 3.766139914318475817e-20 8.437851862854934014e-31 2.031073350459522024e-21 8.890198728181758351e-27 5.332516688805590793e-25 1.117108034895421324e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.437266888155539341e-20 0.000000000000000000e+00 3.653676458145550383e-20 2.771667871993022215e-19 3.650050201252945499e+03 2.770590084677747902e-19 2.720716690335615061e-19 3.841235787614085768e-20 8.393536981403331729e-31 2.030139956090266459e-21 8.860862294878967273e-27 5.320673248418029004e-25 1.116751610954099477e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.431089486129287208e-20 0.000000000000000000e+00 3.607733863422803118e-20 2.775072017185452075e-19 3.654200191560391431e+03 2.719173056005567493e-19 2.723784320221843216e-19 4.174306390345074741e-20 8.349222302294258337e-31 2.029234503659550992e-21 8.831526007374631765e-27 5.308829862107823004e-25 1.116374339658562909e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.446966685131637542e-20 0.000000000000000000e+00 3.561791478474750400e-20 2.782370658484089470e-19 3.658300191345702387e+03 2.730678256094817513e-19 2.726815026049078122e-19 4.026036525131460556e-20 8.305604989950804271e-31 2.028339958251846984e-21 8.802543114694200495e-27 5.297129140483950404e-25 1.116001612949680893e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.453863011104330710e-20 0.000000000000000000e+00 3.516402512605185277e-20 2.782612781622300649e-19 3.662450200571561254e+03 2.737333167729378426e-19 2.729882727351546546e-19 4.057865237259860424e-20 8.261629453592580098e-31 2.027434501693477708e-21 8.773206717361892414e-27 5.285285700183721417e-25 1.115624339935031610e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.482715560947717341e-20 0.000000000000000000e+00 3.470459918221219922e-20 2.785656707775941232e-19 3.666600190912557537e+03 2.744891517372984278e-19 2.732950443438820153e-19 3.879169416314738354e-20 8.217654117347634412e-31 2.026529049255441827e-21 8.743870465733076261e-27 5.273442313777769565e-25 1.115247068637558580e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.500736457442055705e-20 0.000000000000000000e+00 3.424517532901748606e-20 2.785646790604402233e-19 3.670750200118045086e+03 2.754371639084440605e-19 2.736018202118928111e-19 3.885168358747755750e-20 8.174656564304225495e-31 2.025620409064080755e-21 8.714534093081111511e-27 5.261598873535677038e-25 1.114869795625507798e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.460281237534655804e-20 0.000000000000000000e+00 3.383449971218327532e-20 2.788023868510910900e-19 3.674900190481369009e+03 2.788506759548276398e-19 2.739085975422199395e-19 4.327668131662420931e-20 8.132011835743174137e-31 2.024677229436052620e-21 8.685197866078900572e-27 5.249755487066005128e-25 1.114492524326752069e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.443690350663153260e-20 0.000000000000000000e+00 3.350090658511413511e-20 2.797049647216807027e-19 3.679050199666575736e+03 2.750106468174559460e-19 2.742153791094984306e-19 3.839633047657690865e-20 8.089366913771049907e-31 2.023734045530323807e-21 8.655861518606432336e-27 5.237912046881791004e-25 1.114115251317292640e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.455472983156089000e-20 0.000000000000000000e+00 3.316731194506540798e-20 2.792590192436371694e-19 3.683250199438896288e+03 2.789949129006609106e-19 2.745258590236973573e-19 3.853218156299579823e-20 8.046404917042245210e-31 2.022796320122422685e-21 8.626171801427113979e-27 5.225925941825806492e-25 1.113733433716045606e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.541798172244316402e-20 0.000000000000000000e+00 3.282969885802781054e-20 2.795890049404523233e-19 3.687400189835651872e+03 2.804702603297292552e-19 2.748326448986534734e-19 3.958711537686449402e-20 8.003966754376293349e-31 2.021890867672221472e-21 8.596835612474865966e-27 5.214082555260725766e-25 1.113356162415378805e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.567514027991406063e-20 0.000000000000000000e+00 3.249610572827129992e-20 2.800127799244984788e-19 3.691550198990482386e+03 2.807373211303700510e-19 2.751394349772764530e-19 4.006693185872578105e-20 7.961698010095179835e-31 2.020985411129349162e-21 8.567499303895545392e-27 5.202239115163200678e-25 1.112978889409810168e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.550730741621687276e-20 0.000000000000000000e+00 3.216251109066433297e-20 2.803342549804712543e-19 3.695750198764341349e+03 2.765055344892607449e-19 2.754499234787381008e-19 4.326142970155497601e-20 7.919698012356588511e-31 2.020075632699601750e-21 8.537809626254243553e-27 5.190253010102824592e-25 1.112569633694579751e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.549812306249190095e-20 0.000000000000000000e+00 3.182489800350307278e-20 2.810739157458050243e-19 3.699950198538713721e+03 2.737439339408672213e-19 2.757604148461512543e-19 3.963803275672711281e-20 7.877698014612864931e-31 2.019167524640278028e-21 8.508119962174626639e-27 5.178266905040984648e-25 1.112153418112751138e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.548045394351956752e-20 0.000000000000000000e+00 3.148728491630054352e-20 2.808048922750967902e-19 3.704150198313598594e+03 2.777014706853453622e-19 2.760709090698461082e-19 4.028356813633227455e-20 7.836146785662374185e-31 2.018253558938378548e-21 8.478430311799204687e-27 5.166280799977680847e-25 1.111743060165171834e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.570725636067618119e-20 0.000000000000000000e+00 3.114967182905681139e-20 2.811765316917659511e-19 3.708350198088992329e+03 2.772114058368221829e-19 2.763814061401960943e-19 4.190008041736050993e-20 7.795223710927768168e-31 2.017307613043019557e-21 8.448740675272518159e-27 5.154294694912925126e-25 1.111364682364226176e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.532923792079808689e-20 0.000000000000000000e+00 3.081205874177218335e-20 2.816593182550166154e-19 3.712550197864894471e+03 2.769527004140939940e-19 2.766919060476179296e-19 4.136832654464030594e-20 7.754300636188207684e-31 2.016361667147546213e-21 8.419051052741122157e-27 5.142308589846719323e-25 1.110986304563614171e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.561283321332463765e-20 0.000000000000000000e+00 3.048588811897471849e-20 2.818655694722640810e-19 3.716750197641303657e+03 2.793655399580553202e-19 2.770024087825712793e-19 4.083615311847637638e-20 7.713429112591461105e-31 2.015439243362577725e-21 8.389361444353643822e-27 5.130322484779065274e-25 1.110609656327742783e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.562378731887688036e-20 0.000000000000000000e+00 3.020298761226182843e-20 2.820630151458535225e-19 3.720950197418216703e+03 2.822800157833623712e-19 2.773129143355580829e-19 4.192869013385930800e-20 7.672587735450443541e-31 2.014539243410382108e-21 8.359671850260846905e-27 5.118336379709974000e-25 1.110234656901010383e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.710782884719923882e-20 0.000000000000000000e+00 2.992008710551499986e-20 2.825838776779508597e-19 3.725150197195633609e+03 2.785661945491131341e-19 2.776234226971230356e-19 4.238973579566539864e-20 7.631746358304526688e-31 2.013639243458078533e-21 8.329982270615617418e-27 5.106350274639445500e-25 1.109859657474607122e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.552050691071182846e-20 0.000000000000000000e+00 2.963718659873423281e-20 2.828359772498334599e-19 3.729350196973552102e+03 2.800153940072962852e-19 2.779339338578529620e-19 4.029115269411980953e-20 7.592125269095798018e-31 2.012739243505667378e-21 8.300292705573038251e-27 5.094364169567484366e-25 1.109484658048533375e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.534128170446523922e-20 0.000000000000000000e+00 2.935428609191967771e-20 2.827949074632580398e-19 3.733550196751969452e+03 2.800654115591645608e-19 2.782444478083763834e-19 4.052565383960080907e-20 7.552687983040828620e-31 2.011839243553149393e-21 8.270603155290433653e-27 5.082378064494099783e-25 1.109109658622789519e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.541455472538641749e-20 0.000000000000000000e+00 2.907138558507152718e-20 2.831083413362601960e-19 3.737800206003526000e+03 2.812032132255313555e-19 2.785586618843577552e-19 3.711684645013615596e-20 7.512798077300423627e-31 2.010928527284958951e-21 8.240560106188250979e-27 5.070249240651350576e-25 1.108730194072499445e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.570620953526021007e-20 0.000000000000000000e+00 2.878511657678416041e-20 2.829366174109560474e-19 3.742050196305050576e+03 2.787201537073541994e-19 2.788728773967067794e-19 4.291231899178492376e-20 7.473131501152860315e-31 2.010017815077489105e-21 8.210517206490853587e-27 5.058120470888859160e-25 1.108350731214558431e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.563654901516314850e-20 0.000000000000000000e+00 2.849884884491915413e-20 2.840308144067765420e-19 3.746250196084969048e+03 2.926838979186977978e-19 2.791833997264469397e-19 4.158375044989500557e-20 7.433931503206954459e-31 2.009117815124649505e-21 8.180827701819892140e-27 5.046134365811190450e-25 1.107975731789816096e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.484429234332020469e-20 0.000000000000000000e+00 2.821594833796989228e-20 2.840674847724623511e-19 3.750500205305953841e+03 2.840260428315026774e-19 2.794976222505836163e-19 4.077150620036410354e-20 7.394543890599944424e-31 2.008207098863009857e-21 8.150784699604941920e-27 5.034005542055687720e-25 1.107575729726491526e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.688527707300384838e-20 0.000000000000000000e+00 2.792967933174175388e-20 2.843442908710930578e-19 3.754750195641071969e+03 2.813027824507438823e-19 2.798118461872940921e-19 4.072440187347695047e-20 7.355789741442427429e-31 2.007296386648341472e-21 8.120741846857091670e-27 5.021876772197325556e-25 1.107158320580767719e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.612963656862583927e-20 0.000000000000000000e+00 2.764393013546701930e-20 2.845746883727501226e-19 3.759000204841707728e+03 2.815679816057970686e-19 2.801260743182825230e-19 4.065169516213260856e-20 7.317035420256969871e-31 2.006385670391062626e-21 8.090698876892567953e-27 5.009747948499895920e-25 1.106740909582650449e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.702827411510245340e-20 0.000000000000000000e+00 2.739703452562900974e-20 2.849017162317819350e-19 3.763300204607652631e+03 2.980921620120998629e-19 2.804440013846769544e-19 3.931539325947189954e-20 7.278137145049900467e-31 2.005471637959436356e-21 8.063584204744883773e-27 4.998494076129142138e-25 1.106356493707734260e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.129962605229323463e-20 0.000000000000000000e+00 2.714723481593486638e-20 2.852900811969220968e-19 3.767550194976394323e+03 2.963415430136089024e-19 2.807582337266614234e-19 4.190470533142487090e-20 7.239959265466289308e-31 2.004568985137756962e-21 8.038604194997195833e-27 4.987935239022098335e-25 1.105980388924624205e-21 0.000000000000000000e+00 0.000000000000000000e+00 3.011358279277635804e-20 0.000000000000000000e+00 2.690034030009730265e-20 2.867348737087841054e-19 3.771800204146556553e+03 3.125269265109675505e-19 2.810724702300078751e-19 4.178978457175350024e-20 7.201781216988561183e-31 2.003666328322855173e-21 8.013624084681090289e-27 4.977376355204092966e-25 1.105604282478055166e-21 0.000000000000000000e+00 0.000000000000000000e+00 9.353905967229579703e-20 0.000000000000000000e+00 2.665344469202958985e-20 3.003553203356203746e-19 3.776100203914085796e+03 2.935561735517666732e-19 2.813904057410513116e-19 4.174264807239800946e-20 7.163736019311245291e-31 2.002753054035946511e-21 7.988350156825143980e-27 4.966693272851811556e-25 1.105223752091786431e-21 0.000000000000000000e+00 0.000000000000000000e+00 4.281316217063206034e-20 0.000000000000000000e+00 2.640364498224340208e-20 2.888916076562126692e-19 3.780350194316217767e+03 2.818647401883334690e-19 2.817046464036996268e-19 4.054451245685477803e-20 7.126307532408434984e-31 2.001850401207175030e-21 7.963370177101649493e-27 4.956134435661811831e-25 1.104847647306869123e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.978278651811326984e-20 0.000000000000000000e+00 2.615675046446610190e-20 2.864997864339123267e-19 3.784600203456106101e+03 2.997009150350386073e-19 2.820188911952022496e-19 4.691892056070009759e-20 7.088878880487400297e-31 2.000952588746083062e-21 7.938390097468460503e-27 4.945575551919019733e-25 1.104450750570965687e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.600839965099801935e-20 0.000000000000000000e+00 2.590985485815709114e-20 2.875219177013761729e-19 3.788900203225205132e+03 2.832228877320820405e-19 2.823368350660684066e-19 4.315604734079250974e-20 7.051715891466293741e-31 2.000047325636799131e-21 7.913116200760171450e-27 4.934892469562838989e-25 1.104035838931658595e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.618395917115947408e-20 0.000000000000000000e+00 2.566005514827971060e-20 2.872318069200442649e-19 3.793200202994827578e+03 2.869109752684840778e-19 2.826547817264758099e-19 4.002566508797218956e-20 7.014569674969050660e-31 1.999142062527404987e-21 7.887842314715835996e-27 4.924209387205356935e-25 1.103620927292766217e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.514578253790194276e-20 0.000000000000000000e+00 2.541025543837192443e-20 2.870123165599079434e-19 3.797500202764971618e+03 2.844590605605191276e-19 2.829727311670214918e-19 4.290467007752759483e-20 6.977514235216712041e-31 1.998236799417901004e-21 7.862568439438325680e-27 4.913526304846580001e-25 1.103241982291443430e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.509324018643431611e-20 0.000000000000000000e+00 2.516045572843383496e-20 2.877159047112139009e-19 3.801800202535636345e+03 3.058738375169638116e-19 2.832906833783447105e-19 4.000974177559681521e-20 6.940801632132718142e-31 1.997331536308287183e-21 7.837294575031842222e-27 4.902843222486509104e-25 1.102864789893150852e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.512757683942496623e-20 0.000000000000000000e+00 2.495603419813631042e-20 2.875956251303240998e-19 3.806100202306818119e+03 3.237944898963067456e-19 2.836086383511263725e-19 4.363201154900668306e-20 6.904089029044309276e-31 1.996426273198564652e-21 7.812020721601951959e-27 4.892160140125153429e-25 1.102476192228878453e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.515633652850554271e-20 0.000000000000000000e+00 2.476066455903209695e-20 2.884191713416793741e-19 3.810400202078516941e+03 2.852740797781637142e-19 2.839265960760894176e-19 4.019390039652939568e-20 6.867701642609742027e-31 1.995521010088733035e-21 7.786746879255561454e-27 4.881477057762513894e-25 1.102061280591540173e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.534894877449895605e-20 0.000000000000000000e+00 2.456529491990439315e-20 2.882257833276392645e-19 3.814700201850730082e+03 2.833214384797404465e-19 2.842445565439979044e-19 4.393511824875243943e-20 6.831724977848892186e-31 1.994615746978793461e-21 7.761473048100992109e-27 4.870793975398596009e-25 1.101646368954620745e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.538014444107039778e-20 0.000000000000000000e+00 2.436992528075331939e-20 2.890690172927240793e-19 3.819000201623456633e+03 2.888880183727000430e-19 2.845625197456572508e-19 4.292632201480576286e-20 6.795748313083746489e-31 1.993710483868745930e-21 7.736199228247967253e-27 4.860110893033402528e-25 1.101256020453403608e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.565707323401212197e-20 0.000000000000000000e+00 2.417455564157891781e-20 2.892286941072613078e-19 3.823350210875273660e+03 2.846184237914695811e-19 2.848841836672117655e-19 4.309054112809514089e-20 6.759828270822756347e-31 1.992794692447310602e-21 7.710631482654682206e-27 4.849303565223464337e-25 1.100874441267141065e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.544266938450972640e-20 0.000000000000000000e+00 2.397691383161344548e-20 2.895416108757262713e-19 3.827700201165185717e+03 2.892403908156988600e-19 2.852058489654669379e-19 4.216625642262809852e-20 6.724158350445477701e-31 1.991879959766962930e-21 7.685063860311791867e-27 4.838496284523201619e-25 1.100492068862407090e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.592318876084188732e-20 0.000000000000000000e+00 2.377927288317837398e-20 2.897318586085754185e-19 3.832000200939452043e+03 2.852403752636569333e-19 2.855238203764518797e-19 4.459213413820314107e-20 6.688898352296493757e-31 1.991019959812109457e-21 7.659790075308347556e-27 4.827813202154183190e-25 1.100080765154326212e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.516668414679487763e-20 0.000000000000000000e+00 2.358390324393401600e-20 2.903510178525212038e-19 3.836350210160694132e+03 2.894145982365204699e-19 2.858454925725248148e-19 3.998000454979328947e-20 6.653613297698377674e-31 1.990149957967861043e-21 7.634222365509927340e-27 4.817005874420206729e-25 1.099664677941585363e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.547558378407084681e-20 0.000000000000000000e+00 2.338626143535771092e-20 2.899959090482186902e-19 3.840700200484281595e+03 2.885941016657055322e-19 2.861671661220714036e-19 4.094049805467957303e-20 6.618378376077319058e-31 1.989266045116323709e-21 7.608654778941949135e-27 4.806198593636279119e-25 1.099248592536917327e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.701409757946366511e-20 0.000000000000000000e+00 2.318862048539260243e-20 2.905170021029045101e-19 3.845050209685174195e+03 2.885353880665640194e-19 2.864888438092123143e-19 4.298683782843152402e-20 6.583252888768375268e-31 1.988358217109181164e-21 7.583087093700564441e-27 4.795391265952859936e-25 1.098832505327071203e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.647756069059012639e-20 0.000000000000000000e+00 2.300763386422899029e-20 2.910837475323449370e-19 3.849400200031168879e+03 2.891219442586529490e-19 2.868105228344737504e-19 3.987808869871108545e-20 6.548884370001673731e-31 1.987450393036973420e-21 7.557519531685816325e-27 4.784583985113263484e-25 1.098416419921208865e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.577379545419748820e-20 0.000000000000000000e+00 2.283578163623541838e-20 2.909054485408282060e-19 3.853750209211801121e+03 2.879562557233801536e-19 2.871322059757894265e-19 4.041603452445143317e-20 6.514515702425768589e-31 1.986548232576868621e-21 7.531951871499508267e-27 4.773776657480180255e-25 1.098030087269098824e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.577004230640267810e-20 0.000000000000000000e+00 2.266392866415412102e-20 2.912831260066831461e-19 3.858150208973207100e+03 2.916834630149230434e-19 2.874575886811591445e-19 4.599856425215618242e-20 6.479905807680102009e-31 1.985637887798646841e-21 7.506090399023210199e-27 4.762845131354045938e-25 1.097650777517451949e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.566167965769444018e-20 0.000000000000000000e+00 2.249010074684275284e-20 2.924106250467436619e-19 3.862500199352745767e+03 2.834612745489958615e-19 2.877792758822524728e-19 4.233917686070472811e-20 6.445968692652957507e-31 1.984737889789087106e-21 7.480522874938278350e-27 4.752037850431111529e-25 1.097273190991751272e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.561652663801611578e-20 0.000000000000000000e+00 2.231824851752398164e-20 2.921585885077728764e-19 3.866850208503039994e+03 2.918849871677410349e-19 2.881009671673019149e-19 3.745961709885086188e-20 6.412031431182893658e-31 1.983837887895922740e-21 7.454955253448371884e-27 4.741230522873400446e-25 1.096860690747646256e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.603296705893390221e-20 0.000000000000000000e+00 2.214639554664122659e-20 2.918185185705555327e-19 3.871250208266058507e+03 2.894132041743611383e-19 2.884263580846233301e-19 4.246263020312663182e-20 6.378118081115027663e-31 1.982927543117366932e-21 7.429093820326526960e-27 4.730298996743260266e-25 1.096443450022047672e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.585599710285914358e-20 0.000000000000000000e+00 2.197256762926615829e-20 2.928005798562898559e-19 3.875650208029615442e+03 2.887038806756728273e-19 2.887517517416213061e-19 4.289414866054575224e-20 6.344504968167199550e-31 1.982033148407920961e-21 7.403232400698842044e-27 4.719367470611782042e-25 1.096026209296878096e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.581498005315095935e-20 0.000000000000000000e+00 2.179873971186981447e-20 2.931687406586025282e-19 3.880050207793708523e+03 2.916785574700439727e-19 2.890771481290442532e-19 4.033691432068399950e-20 6.310891855215276142e-31 1.981160734661592417e-21 7.377370994707281899e-27 4.708435944478972203e-25 1.095608968572139221e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.583630453228034609e-20 0.000000000000000000e+00 2.162491179445229145e-20 2.931146788132298312e-19 3.884450207558336842e+03 2.915797606950169370e-19 2.894025472376823263e-19 4.332938967763346444e-20 6.277744343250520107e-31 1.980288320915157421e-21 7.351509602495790055e-27 4.697504418344831668e-25 1.095191727847831236e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.618013821105848188e-20 0.000000000000000000e+00 2.145108387701362532e-20 2.938678907544990820e-19 3.888850207323496306e+03 2.930245653669947325e-19 2.897279490583663655e-19 4.368620370721614638e-20 6.244708279439978408e-31 1.979392265164411161e-21 7.325648224210367731e-27 4.686572892209372375e-25 1.094777283485798787e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.579129812828960727e-20 0.000000000000000000e+00 2.128614545527674849e-20 2.942080054588844215e-19 3.893250207089187370e+03 2.929390666770567173e-19 2.900533535819690517e-19 4.418956473395460590e-20 6.211686990093233545e-31 1.978489701109910064e-21 7.299786859999053748e-27 4.675641366072592488e-25 1.094363608922379514e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.593365525759893213e-20 0.000000000000000000e+00 2.113118103871453339e-20 2.946000437727507639e-19 3.897650206855407760e+03 2.893074541655180495e-19 2.903787607994034142e-19 4.230357051786970227e-20 6.179083713136978257e-31 1.977591839677996531e-21 7.273925510012010622e-27 4.664709839934497517e-25 1.093954636974931183e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.590199985295648840e-20 0.000000000000000000e+00 2.097621662213367589e-20 2.946309550463246501e-19 3.902050206622154747e+03 2.934670623720324673e-19 2.907041707016231674e-19 3.978573404822714543e-20 6.146480436176821229e-31 1.976726882458892760e-21 7.248064174401546087e-27 4.653778313795093889e-25 1.093578569190753895e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.666785296943737153e-20 0.000000000000000000e+00 2.082125220553426927e-20 2.946324230741814300e-19 3.906450206389427422e+03 2.963207432011068058e-19 2.910295832796225185e-19 3.991651893818390629e-20 6.114096070944622670e-31 1.975861925239685169e-21 7.222202853322137493e-27 4.642846787654384361e-25 1.093202501406925118e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.610896814868701829e-20 0.000000000000000000e+00 2.066628778891635267e-20 2.949292122800235334e-19 3.910850206157223965e+03 2.968556836347655392e-19 2.913549985244358783e-19 4.151354399103819084e-20 6.082330218962481519e-31 1.974979444890826111e-21 7.196341546930490634e-27 4.631915261512372606e-25 1.092808910520593527e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.588160252080377384e-20 0.000000000000000000e+00 2.051132337227998325e-20 2.954473624189564467e-19 3.915300215394302086e+03 2.892621046913920757e-19 2.916841150735825814e-19 4.050991472288651950e-20 6.050203323006989793e-31 1.974066622483220250e-21 7.170186321489785276e-27 4.620859489949986525e-25 1.092390534221435300e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.615798759646943116e-20 0.000000000000000000e+00 2.035459766277031895e-20 2.956368661764264415e-19 3.919750205689133054e+03 2.899336062122863598e-19 2.920132329311875999e-19 3.999358200102599756e-20 6.018216414581812409e-31 1.973153803961203631e-21 7.144031222739408464e-27 4.609803765448436883e-25 1.091972159703657888e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.590089934036201195e-20 0.000000000000000000e+00 2.019787262039121075e-20 2.958666814728601510e-19 3.924150205458502569e+03 2.935174384521343395e-19 2.923386561829479107e-19 4.021414254572547218e-20 5.986736741435103888e-31 1.972288519275037489e-21 7.118169961720797483e-27 4.598872239302518445e-25 1.091561393458258179e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.570974085837892019e-20 0.000000000000000000e+00 2.004290820369944075e-20 2.961969998415405818e-19 3.928600214665099429e+03 2.930374622653615752e-19 2.926677808004785856e-19 4.649960898702192533e-20 5.954899277192785444e-31 1.971421144599175592e-21 7.092014782860469183e-27 4.587816467815860833e-25 1.091146562725242815e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.589395059169413739e-20 0.000000000000000000e+00 1.988618249526330485e-20 2.974387307944785943e-19 3.933050204993574425e+03 2.900158967641331142e-19 2.929969067039483992e-19 4.172246345966176869e-20 5.923650184560901445e-31 1.970547415933510003e-21 7.065859730826773393e-27 4.576760743230725277e-25 1.090731733752531746e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.578858304027902043e-20 0.000000000000000000e+00 1.973732437942073948e-20 2.970384914053165463e-19 3.937500214179888644e+03 2.939027000059430088e-19 2.933260366753196301e-19 4.309888934232469100e-20 5.892643668940131645e-31 1.969642329319344475e-21 7.039704584001497269e-27 4.565704971794458719e-25 1.090316903022371799e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.537352913928669171e-20 0.000000000000000000e+00 1.960925962469805555e-20 2.975291831022314253e-19 3.941950204530747669e+03 2.900326228902423610e-19 2.936551679177462205e-19 4.078912793400847839e-20 5.861637284559953235e-31 1.968737246536119175e-21 7.017096838072572019e-27 4.555797046387376251e-25 1.089902074048539590e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.565215757197708816e-20 0.000000000000000000e+00 1.948119541203221837e-20 2.975343365509952930e-19 3.946400213696865649e+03 2.932972778292330859e-19 2.939843032070111509e-19 4.192880157539617431e-20 5.830798519758297441e-31 1.967851653262475488e-21 6.995364363869039251e-27 4.546172320252893809e-25 1.089487243321229229e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.575126914637964936e-20 0.000000000000000000e+00 1.935313065789075301e-20 2.980142622466804148e-19 3.950900213453468950e+03 2.927561579594910207e-19 2.943171386330645182e-19 4.278024506225692200e-20 5.799627789736946343e-31 1.966974534665849380e-21 6.973387761008374133e-27 4.536439471702308336e-25 1.089067752461760847e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.574077389057909567e-20 0.000000000000000000e+00 1.922362724768344789e-20 2.984545230442467558e-19 3.955400213210626134e+03 2.899970325219292527e-19 2.946499767560962424e-19 4.468332232379022611e-20 5.768648174047331597e-31 1.966097416069115314e-21 6.951411168285877133e-27 4.526706623150525329e-25 1.088648261602736519e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.565748397547779025e-20 0.000000000000000000e+00 1.909412383746019969e-20 2.990484929908765539e-19 3.959850203606192281e+03 2.973619593122539178e-19 2.949791186283423045e-19 4.318511382207076574e-20 5.738886638281785725e-31 1.965203320281104011e-21 6.929678815726197602e-27 4.517081937614031588e-25 1.088236527069992140e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.669884173563840571e-20 0.000000000000000000e+00 1.896605962350775704e-20 2.992010085186314446e-19 3.964300212731961437e+03 2.917837984995502183e-19 2.953082645055885750e-19 3.847597134088791996e-20 5.709124977248641128e-31 1.964305839449016169e-21 6.907946381799726072e-27 4.507457211566818581e-25 1.087825182320838794e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.645922525812220261e-20 0.000000000000000000e+00 1.883799487052747397e-20 2.988614887603093626e-19 3.968800212490755712e+03 2.937556994041195835e-19 2.956411106057145175e-19 4.130789974198310036e-20 5.679046968206888807e-31 1.963406681619433866e-21 6.885969819842717216e-27 4.497724363011494397e-25 1.087400811462341600e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.580382661599251198e-20 0.000000000000000000e+00 1.870849146025711270e-20 2.995243142988987344e-19 3.973300212250097502e+03 2.949734485331800630e-19 2.959739593667471120e-19 4.085914385689075517e-20 5.648998582717090589e-31 1.962536933766787773e-21 6.863993268415048340e-27 4.487991514454986453e-25 1.086947030672547468e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.603104413075702863e-20 0.000000000000000000e+00 1.857898804997099491e-20 2.997953642705229752e-19 3.977800212009983170e+03 2.908029392573246827e-19 2.963068107797189879e-19 4.198314569167314788e-20 5.618950197223661257e-31 1.961667185914036733e-21 6.842016727618219190e-27 4.478258665897301178e-25 1.086493249883281839e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.651859234236706147e-20 0.000000000000000000e+00 1.845073388975250864e-20 3.002975736108954310e-19 3.982300211770411806e+03 2.933204864028324880e-19 2.966396648357032192e-19 4.200142690359515437e-20 5.589465295201143331e-31 1.960797438061180744e-21 6.820040197555028127e-27 4.468525817338442245e-25 1.086061319579919005e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.611821271877190865e-20 0.000000000000000000e+00 1.833538404337867864e-20 3.005997637408001011e-19 3.986800211531382047e+03 2.935198607910116565e-19 2.969725215258127948e-19 4.463095456078259271e-20 5.560322439606288172e-31 1.959927690208220183e-21 6.798063678329607992e-27 4.458792968778412410e-25 1.085645353857348964e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.667963559491411499e-20 0.000000000000000000e+00 1.822003419699096388e-20 3.013300523988748724e-19 3.991300211292889799e+03 2.948134569757606332e-19 2.973053808412001851e-19 4.046516798046233698e-20 5.531179584007951662e-31 1.959057942355155426e-21 6.776087170047451942e-27 4.449060120217219018e-25 1.085229388135221473e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.631511070700799876e-20 0.000000000000000000e+00 1.810468435058946970e-20 3.010430157978737775e-19 3.995850220541305589e+03 2.949994788533877445e-19 2.976419419555302545e-19 4.241534030848987509e-20 5.501878581478322300e-31 1.958149955891738887e-21 6.753866443234153048e-27 4.439219108369693995e-25 1.084812073669399571e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.670350774793234146e-20 0.000000000000000000e+00 1.798805259597927141e-20 3.016577117868980136e-19 4.000400210812246769e+03 3.007634697323444881e-19 2.979785043319363720e-19 4.031788562683199552e-20 5.472613044055628255e-31 1.957239957837550502e-21 6.731645820512101478e-27 4.429378137567701433e-25 1.084394991872992532e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.661809298567979306e-20 0.000000000000000000e+00 1.787142132782438255e-20 3.016906965105497403e-19 4.004900210575372967e+03 3.025897048617601721e-19 2.983113715281238426e-19 4.358895656826775764e-20 5.443712962097655327e-31 1.956350792973053663e-21 6.709669345958114120e-27 4.419645289003008191e-25 1.083982492533202279e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.737168475216694251e-20 0.000000000000000000e+00 1.775607148138140263e-20 3.025090533355091444e-19 4.009450219793232918e+03 3.046239025065128452e-19 2.986479405816317215e-19 4.414327666848587060e-20 5.415112904156821042e-31 1.955478707872963677e-21 6.687448653742077744e-27 4.409804277221570746e-25 1.083565409000984862e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.685001889444647508e-20 0.000000000000000000e+00 1.763943972755444996e-20 3.028849489005562480e-19 4.014000210097985018e+03 3.083527382538708337e-19 2.989845108750949950e-19 4.336815544998996685e-20 5.386512965098378977e-31 1.954606626397886116e-21 6.665228065646201091e-27 4.399963306346450497e-25 1.083148327202963917e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.689296361473848790e-20 0.000000000000000000e+00 1.752280845853287457e-20 3.031005598541083447e-19 4.018500209862713291e+03 3.137103899490713145e-19 2.993173858727102545e-19 4.225571926777552351e-20 5.358351081802250592e-31 1.953748720439319078e-21 6.643251625835678361e-27 4.390230457778292302e-25 1.082738024989771591e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.740285646265485232e-20 0.000000000000000000e+00 1.740745861204883021e-20 3.032941011308760931e-19 4.023050219050217038e+03 3.183233690891549594e-19 2.996539627855166504e-19 4.618606650374275280e-20 5.330184358260561429e-31 1.952883842659876024e-21 6.621030969256050407e-27 4.380389446062510808e-25 1.082324388433126484e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.730051580354593610e-20 0.000000000000000000e+00 1.729082685900000439e-20 3.041856602048578604e-19 4.027650218800038601e+03 3.294357660604524705e-19 2.999942402958003777e-19 4.247680281063061062e-20 5.301708169333095325e-31 1.952009462542141455e-21 6.598566188533680590e-27 4.370440311991548115e-25 1.081906207287462295e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.735975337485079828e-20 0.000000000000000000e+00 1.718244747044019054e-20 3.039776330392615744e-19 4.032200209149672901e+03 3.284561743950643284e-19 3.003308210598727056e-19 4.364837238172987749e-20 5.273885349394104871e-31 1.951144588343450547e-21 6.576345648434169550e-27 4.360599341019354073e-25 1.081455380691039204e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.736117814591866439e-20 0.000000000000000000e+00 1.707628232719530629e-20 3.044696518964395791e-19 4.036750218306801344e+03 3.369205056894878438e-19 3.006674058100846098e-19 4.413544315145370837e-20 5.246370333388792247e-31 1.950279710569781521e-21 6.554125028846474944e-27 4.350758329369269856e-25 1.081004140815762717e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.671830747090519042e-20 0.000000000000000000e+00 1.697011674511425709e-20 3.048299281351276377e-19 4.041350218058316386e+03 3.381337593177979893e-19 3.010076912195162225e-19 4.536729910345853559e-20 5.218553012056795595e-31 1.949405330451724960e-21 6.531660285745181935e-27 4.340809195294645681e-25 1.080560754903426264e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.678418340876654500e-20 0.000000000000000000e+00 1.686278473009464761e-20 3.053438260644462820e-19 4.045900208441462382e+03 3.445919003074062548e-19 3.013442797728610731e-19 4.121425686523339557e-20 5.191359389120112897e-31 1.948540456246664190e-21 6.509439783084230395e-27 4.330968224249969555e-25 1.080147120058856893e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.707892335022559766e-20 0.000000000000000000e+00 1.675661958606782978e-20 3.050974063662801226e-19 4.050450217568412427e+03 3.483765387423536449e-19 3.016808722815734729e-19 4.377232472822758411e-20 5.164274295419528542e-31 1.947675578478731576e-21 6.487219201631373366e-27 4.321127212665157418e-25 1.079733483510801922e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.717252242541600290e-20 0.000000000000000000e+00 1.665045400469093668e-20 3.057849857701312099e-19 4.055050217321605487e+03 3.458007311730727348e-19 3.020211655107229014e-19 4.297499636474462548e-20 5.136891619723355351e-31 1.946806106570516885e-21 6.464754497323542025e-27 4.311178078586902986e-25 1.079291828356021957e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.696676300699338371e-20 0.000000000000000000e+00 1.654312198963217064e-20 3.059904174744004247e-19 4.059650217075357887e+03 3.529381705326537332e-19 3.023614613478442196e-19 4.121474480498304326e-20 5.109789272658521681e-31 1.945938893502186715e-21 6.442289806312686249e-27 4.301228944507439080e-25 1.078839370070863467e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.755946339753388241e-20 0.000000000000000000e+00 1.643578997456035642e-20 3.061119550383318278e-19 4.064250216829668261e+03 3.498518898911451729e-19 3.027017597841417536e-19 4.808575151831981870e-20 5.082696360719749219e-31 1.945071446387748964e-21 6.419825128738425408e-27 4.291279810426768456e-25 1.078388031134936424e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.792504874201547096e-20 0.000000000000000000e+00 1.632845795947552110e-20 3.074629522578244829e-19 4.068850216584533428e+03 3.522658462526932032e-19 3.030420608108591666e-19 4.434504293838671365e-20 5.055736254638934133e-31 1.944197066269055568e-21 6.397360464742355490e-27 4.281330676344897543e-25 1.077969849993566833e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.758368481901719703e-20 0.000000000000000000e+00 1.622112594437774294e-20 3.072103941500532159e-19 4.073450216339952021e+03 3.438362725601332734e-19 3.033823644192797479e-19 4.403992692715828206e-20 5.029286256045275618e-31 1.943322686150256847e-21 6.374895814468057704e-27 4.271381542261830012e-25 1.077551668852655026e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.767150094545035098e-20 0.000000000000000000e+00 1.612606417138094076e-20 3.075022661974228058e-19 4.078050216095922224e+03 3.310350964101609990e-19 3.037226706007253533e-19 4.228739260640538219e-20 5.002836257448446664e-31 1.942454024632469845e-21 6.352431178061145839e-27 4.261432408177569539e-25 1.077121180307361032e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.908422433295707513e-20 0.000000000000000000e+00 1.603579598721296958e-20 3.076718575032101121e-19 4.082650215852443125e+03 3.133275551480417718e-19 3.040629793465569352e-19 4.413014402860180317e-20 4.976569091584617448e-31 1.941593862076372503e-21 6.329966555669296395e-27 4.251483274092117041e-25 1.076672400547403452e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.982634345663548285e-20 0.000000000000000000e+00 1.594552780303419514e-20 3.083083485461134871e-19 4.087300225087460149e+03 2.887721525419395954e-19 3.044069903994538675e-19 4.285560964243306939e-20 4.950267476849052428e-31 1.940724348154377500e-21 6.307257720696993145e-27 4.241425976738527359e-25 1.076218741822185348e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.851553296677462490e-20 0.000000000000000000e+00 1.585427825688704769e-20 3.083817874647010215e-19 4.091950215361863684e+03 2.816179295063898387e-19 3.047510026523879741e-19 4.350498778652888404e-20 4.923965969359458645e-31 1.939854837777863042e-21 6.284548992955047388e-27 4.231368720394001345e-25 1.075793135434678489e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.794672178461730428e-20 0.000000000000000000e+00 1.576302908281386315e-20 3.087739235370482596e-19 4.096550215120034409e+03 2.268692853947687823e-18 3.050913190950218265e-19 4.269394318099813292e-20 4.898270123829886043e-31 1.938994675221457250e-21 6.262084413832022883e-27 4.221419586304981038e-25 1.075381753989475328e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.812817824912706653e-20 0.000000000000000000e+00 1.567276089860271202e-20 3.090026993389299813e-19 4.101200224324581541e+03 3.065562448600699114e-18 3.054353378998428295e-19 4.229766413418308124e-20 4.872460770415500118e-31 1.938125161305159539e-21 6.239375623229294874e-27 4.211362289017292508e-25 1.074962646311121935e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.797213830856736912e-20 0.000000000000000000e+00 1.558151135305349058e-20 3.092742005965518435e-19 4.105850214632774623e+03 9.349458442637349167e-19 3.057793578832227472e-19 4.535907987894834116e-20 4.846651521883202645e-31 1.937255650922326752e-21 6.216666940025787593e-27 4.201305032599684724e-25 1.074508989434688621e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.814417970548299605e-20 0.000000000000000000e+00 1.549026217831723845e-20 3.100524614378680864e-19 4.110500223817048209e+03 3.636938978896884568e-19 3.061233818309909810e-19 4.359982908239451735e-20 4.821223584750371817e-31 1.936386137009820339e-21 6.193958179922384783e-27 4.191247735355844889e-25 1.074055330717293103e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.775974386488544213e-20 0.000000000000000000e+00 1.539901263316585396e-20 3.101127396257371094e-19 4.115150214147716724e+03 3.841575076496436043e-19 3.064674069431256628e-19 4.176175855786774099e-20 4.795846893333391530e-31 1.935516626622784737e-21 6.171249527344295707e-27 4.181190478889625822e-25 1.073618342221268761e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.775062984905903135e-20 0.000000000000000000e+00 1.530776345798855484e-20 3.101944992412737665e-19 4.119800223311804984e+03 3.895868420773848295e-19 3.068114359992566256e-19 4.288063941275544493e-20 4.770537272832547046e-31 1.934647112714052695e-21 6.148540798414698876e-27 4.171133181689443663e-25 1.073202488399859937e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.802784480343237915e-20 0.000000000000000000e+00 1.522109161450797430e-20 3.106985451169226241e-19 4.124500223057334551e+03 4.012107896214316633e-19 3.071591661715987910e-19 4.214757564716515835e-20 4.745518812648651215e-31 1.933768250973018820e-21 6.125587952135014985e-27 4.160967762092720352e-25 1.072782163883622916e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.791101269670692862e-20 0.000000000000000000e+00 1.513753553852299062e-20 3.109308784530089122e-19 4.129150213421643457e+03 4.050396330513171255e-19 3.075031989395849838e-19 4.269150045613872860e-20 4.720766556247868295e-31 1.932904395897598560e-21 6.106593588657738276e-27 4.152176984920608941e-25 1.072338772848722823e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.787662129653500729e-20 0.000000000000000000e+00 1.505486852378981285e-20 3.113388672404116656e-19 4.133800222555512846e+03 4.164496344649773161e-19 3.078472356211860572e-19 4.483586630332197966e-20 4.696045331566118866e-31 1.932041894203412899e-21 6.087702740795485593e-27 4.143421491776316152e-25 1.071888772677121308e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.787998475166791545e-20 0.000000000000000000e+00 1.497220117537346153e-20 3.119758288411537134e-19 4.138500222302760449e+03 4.057835829533974093e-19 3.081949734773773143e-19 4.680951537067416970e-20 4.671124402673735290e-31 1.931170120056746111e-21 6.068608813932184533e-27 4.134571871403428957e-25 1.071433934712491139e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.855294833364214870e-20 0.000000000000000000e+00 1.488864509935793380e-20 3.126436205004095808e-19 4.143200222050582852e+03 3.806914851314926350e-19 3.085427138958022250e-19 4.295132175516441917e-20 4.646203473778303891e-31 1.930298345909972494e-21 6.049514897075630692e-27 4.125722251029459023e-25 1.070979096748417120e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.804372583590449672e-20 0.000000000000000000e+00 1.480508902333218962e-20 3.123988829842910238e-19 4.147900221798976418e+03 3.636031632488415366e-19 3.088904568678072488e-19 4.508351440818652479e-20 4.621666031022075703e-31 1.929426571763092801e-21 6.030420990320913269e-27 4.116872630654413694e-25 1.070524258784901131e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.805665294583808588e-20 0.000000000000000000e+00 1.472153294729628916e-20 3.130390911253331589e-19 4.152600221547940237e+03 3.507554818214199700e-19 3.092382023847779421e-19 4.718476670675243163e-20 4.597412597202995617e-31 1.928558359235178787e-21 6.011327093764318913e-27 4.108023010278294809e-25 1.070071279055027590e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.867058060190329119e-20 0.000000000000000000e+00 1.463797687125025350e-20 3.137234345092681023e-19 4.157300221297470671e+03 3.491594206508221462e-19 3.095859504381380904e-19 4.057840507207537542e-20 4.573159163380992072e-31 1.927693559281265158e-21 5.992233207503372614e-27 4.099173389901108795e-25 1.069620079796323596e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.843780416723323891e-20 0.000000000000000000e+00 1.455442079519414282e-20 3.131241152383718970e-19 4.162000221047567720e+03 3.515646479429861718e-19 3.099337010193503835e-19 4.269013027728871384e-20 4.549100409418578598e-31 1.926828759327247710e-21 5.973139331636828383e-27 4.090323769522855653e-25 1.069168880538170485e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.862851940240189677e-20 0.000000000000000000e+00 1.447086471912796013e-20 3.137556847338691861e-19 4.166700220798228656e+03 3.438259764235466539e-19 3.102814541199153074e-19 4.147068415964495372e-20 4.525094256845971131e-31 1.925995961139511810e-21 5.954045466264721621e-27 4.081474149143541351e-25 1.068717681280569575e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.911347094655728889e-20 0.000000000000000000e+00 1.438956250455348857e-20 3.139611987399505166e-19 4.171400220549450751e+03 3.247228703117401261e-19 3.106292097313714813e-19 4.541286293211551796e-20 4.501101934239093948e-31 1.925168761183296460e-21 5.934951611488372709e-27 4.072624528763170023e-25 1.068266482023521429e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.863899308378241197e-20 0.000000000000000000e+00 1.431240336445338816e-20 3.148173096884495399e-19 4.176100220301233094e+03 3.205156785949935491e-19 3.109769678452955618e-19 4.287705647152388014e-20 4.477744359715084496e-31 1.924334359464573206e-21 5.915857767410402792e-27 4.063774908381743965e-25 1.067815282767027552e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.901447552719556764e-20 0.000000000000000000e+00 1.423524422434408843e-20 3.148240020265094068e-19 4.180850229518712695e+03 3.229527135697700927e-19 3.113284287481533870e-19 4.393489844859183607e-20 4.454138253300942867e-31 1.923460357768556804e-21 5.896560769844327442e-27 4.054831125274728250e-25 1.067359282610102383e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.867834925384127739e-20 0.000000000000000000e+00 1.415726408687855141e-20 3.152932185466517534e-19 4.185600219801217463e+03 3.125394175900884680e-19 3.116798907887465269e-19 4.517581234680045978e-20 4.430591285862717165e-31 1.922586359556576259e-21 5.877263860346318988e-27 4.045887377820340024e-25 1.066903284271553939e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.816615829730077721e-20 0.000000000000000000e+00 1.407928426026545303e-20 3.157820110724071886e-19 4.190300219554679643e+03 3.192846147006940385e-19 3.120276564125283952e-19 4.027705066435407390e-20 4.407485943563255030e-31 1.921725356747955240e-21 5.858170049228161017e-27 4.037037757435750691e-25 1.066454066133230421e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.826890093906758086e-20 0.000000000000000000e+00 1.400212512012857639e-20 3.154649612535439750e-19 4.195050228741804858e+03 3.204157756624878035e-19 3.123791248772681428e-19 4.345883854517546466e-20 4.384134753360899463e-31 1.920858291578876833e-21 5.838873085430337682e-27 4.028093974385889257e-25 1.066001685029903284e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.868585551375541064e-20 0.000000000000000000e+00 1.392414498316136472e-20 3.162550511421242512e-19 4.199800219058044604e+03 3.087173565378362999e-19 3.127305944589236134e-19 4.416833829858610689e-20 4.360998944538513714e-31 1.919991229854483999e-21 5.819576209773677994e-27 4.019150226867981173e-25 1.065549305724415198e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.951010142080298551e-20 0.000000000000000000e+00 1.384616515599444412e-20 3.167466636406362868e-19 4.204550228224972670e+03 3.155782277779859067e-19 3.130820679401913946e-19 4.204376694893612135e-20 4.338112536734223242e-31 1.919157896659131833e-21 5.800279269128528141e-27 4.010206443856148817e-25 1.065096924624241771e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.846275774199656425e-20 0.000000000000000000e+00 1.376818501935880235e-20 3.167385570873587981e-19 4.209350227964723672e+03 3.122411601604646833e-19 3.134372429734921952e-19 4.552617113387853499e-20 4.314985265260878078e-31 1.918319801466476666e-21 5.780779253376955639e-27 4.001168533692083271e-25 1.064639782525391993e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.791105555001999503e-20 0.000000000000000000e+00 1.368938419552820587e-20 3.175351257741279152e-19 4.214100218314700214e+03 3.169978420486759746e-19 3.137887200728551108e-19 4.690653769433282664e-20 4.292398967966871853e-31 1.917480912529856321e-21 5.761482412835809851e-27 3.992224786110652116e-25 1.064187403218546353e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.783645522297048158e-20 0.000000000000000000e+00 1.361321535795071423e-20 3.180752302817243079e-19 4.218850227451393039e+03 3.196471153839074067e-19 3.141402010418725930e-19 4.567055199292415355e-20 4.269944379320687018e-31 1.916613847369983634e-21 5.742185507920419202e-27 3.983281003155749502e-25 1.063735022123110262e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.845375208996741983e-20 0.000000000000000000e+00 1.354628532054575155e-20 3.182745873976527378e-19 4.223650227192903913e+03 3.181082844041876430e-19 3.144953836185789071e-19 4.666333576557040771e-20 4.247253471451726435e-31 1.915737656940978064e-21 5.722685528508049932e-27 3.974243092988370073e-25 1.063277880025972568e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.812722331912565435e-20 0.000000000000000000e+00 1.347865089016930837e-20 3.187473671860308149e-19 4.228450226935002320e+03 3.132111946738514078e-19 3.148505687102947354e-19 4.608967358231622832e-20 4.224854581205252643e-31 1.914865706933031088e-21 5.703185561542725885e-27 3.965205182819884484e-25 1.062822950319499851e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.859317741342196447e-20 0.000000000000000000e+00 1.341101645978458519e-20 3.190383935208874959e-19 4.233250226677684623e+03 3.153112767836697074e-19 3.152057563085179158e-19 4.326148179844022037e-20 4.202478642555154629e-31 1.913996415641049098e-21 5.683685607152601345e-27 3.956167272650299625e-25 1.062369407767573868e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.834328606642707040e-20 0.000000000000000000e+00 1.334338202939163469e-20 3.189757649356967290e-19 4.238050226420949912e+03 3.201582325574806400e-19 3.155609464047847565e-19 4.597102315540229517e-20 4.180170393504229717e-31 1.913127124348961785e-21 5.664185665467579771e-27 3.947129362479616413e-25 1.061915865216217201e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.863089703444623674e-20 0.000000000000000000e+00 1.327574759899046889e-20 3.197189224698981448e-19 4.242850226164797277e+03 3.248058495715195022e-19 3.159161389906696029e-19 4.717406426982543966e-20 4.158227537532356670e-31 1.912294449010822431e-21 5.644685736619362594e-27 3.938091452307837604e-25 1.061462322665430602e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.892926776240186340e-20 0.000000000000000000e+00 1.320811316858110284e-20 3.202591984915932136e-19 4.247650225909222172e+03 3.303372045912269345e-19 3.162713340577841635e-19 4.221864095827783599e-20 4.136284681557843050e-31 1.911462952992103050e-21 5.625185820741488669e-27 3.929053542134971462e-25 1.061008780115215010e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.871159486335672022e-20 0.000000000000000000e+00 1.314047873816359823e-20 3.199024004055917767e-19 4.252450225654225505e+03 3.226643852706795529e-19 3.166265315977783763e-19 4.479556781780464365e-20 4.114570638134938530e-31 1.910621443827756127e-21 5.605685917969336431e-27 3.920015631961016152e-25 1.060556381923209277e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.873258664586235667e-20 0.000000000000000000e+00 1.307284430773794303e-20 3.206019147210324022e-19 4.257250225399802730e+03 3.190024276546889392e-19 3.169817316023389648e-19 4.608273728826822673e-20 4.093221385535206854e-31 1.909758943873472881e-21 5.586186028440194208e-27 3.910977721785980397e-25 1.060106382675299938e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.887512991460990929e-20 0.000000000000000000e+00 1.300520987730420193e-20 3.211404892936457455e-19 4.262050225145952936e+03 3.384769530097131388e-19 3.173369340631901116e-19 4.376728765094144832e-20 4.071872132932925691e-31 1.908896443919086568e-21 5.566686152293260219e-27 3.901939811609865574e-25 1.059656383427955213e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.958698014895868062e-20 0.000000000000000000e+00 1.293757544686238697e-20 3.212072580066980223e-19 4.266850224892674305e+03 3.231849725672597989e-19 3.176921389720928812e-19 4.420082642338287326e-20 4.050607961668184491e-31 1.908058555096571716e-21 5.547186289669692077e-27 3.892901901432675359e-25 1.059206384181176418e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.873899135572684974e-20 0.000000000000000000e+00 1.287539735062220402e-20 3.215644515192958074e-19 4.271700234098831061e+03 3.385431804424744244e-19 3.180510471103733477e-19 4.282312920624881524e-20 4.029181055324565956e-31 1.907224959764263283e-21 5.527483278921419541e-27 3.883769828541685787e-25 1.058751696555805491e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.881003101296474883e-20 0.000000000000000000e+00 1.281269907118227458e-20 3.217344090232972768e-19 4.276550224382576744e+03 3.371990244741721478e-19 3.184099563308397723e-19 4.597067745378362843e-20 4.007754232578464768e-31 1.906390975306255466e-21 5.507780359149669178e-27 3.874637791279667339e-25 1.058296618327690041e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.880593018381635191e-20 0.000000000000000000e+00 1.275000103636097569e-20 3.225200510528084421e-19 4.281400233568452677e+03 3.281072810439071223e-19 3.187688694242004665e-19 4.486794560763155557e-20 3.986613910221888464e-31 1.905519489280668518e-21 5.488077376845452048e-27 3.865505718426864344e-25 1.057804040070334825e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.813631930295930541e-20 0.000000000000000000e+00 1.268730275718322550e-20 3.226784286874539890e-19 4.286250223874787480e+03 3.237529611117468241e-19 3.191277835861674349e-19 4.630118649294346211e-20 3.965534549368087506e-31 1.904648006647499210e-21 5.468374485649508023e-27 3.856373681122312745e-25 1.057311463731175741e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.850211918738051930e-20 0.000000000000000000e+00 1.262460472206990748e-20 3.232534559409935746e-19 4.291100233040472631e+03 3.266599923563017246e-19 3.194867016012243353e-19 4.812043451159008966e-20 3.944484343170259302e-31 1.903792983512477608e-21 5.448671532405437638e-27 3.847241608307527350e-25 1.056834258081845670e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.889055947152312273e-20 0.000000000000000000e+00 1.256190644315317196e-20 3.238930761451514324e-19 4.295950223369291962e+03 3.250716790712850426e-19 3.198456206714435077e-19 4.336077507598136871e-20 3.923877273150920213e-31 1.902965853378880571e-21 5.428968670411097874e-27 3.838109570960639587e-25 1.056383096926065449e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.857510001278439306e-20 0.000000000000000000e+00 1.249920840774918596e-20 3.235542916631302854e-19 4.300800232514875461e+03 3.220062442876737122e-19 3.202045435751113526e-19 4.643619974786736999e-20 3.903270123181240806e-31 1.902138720036222699e-21 5.409265746861266767e-27 3.828977498183703273e-25 1.055931934020519568e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.864653486214315462e-20 0.000000000000000000e+00 1.243651012909231407e-20 3.243368057187336120e-19 4.305700232250266708e+03 3.245333606479650152e-19 3.205671684819747880e-19 4.530123761484536258e-20 3.882537694312217200e-31 1.901303061166621042e-21 5.389359754283814000e-27 3.819751298222552976e-25 1.055476120835773956e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.854999792541059458e-20 0.000000000000000000e+00 1.237316559929737105e-20 3.245264831585949589e-19 4.310550222612730977e+03 3.258511142842942246e-19 3.209260948778421824e-19 4.612994008740167544e-20 3.862232401328033290e-31 1.900475931027286087e-21 5.369656937462782259e-27 3.810619260812315710e-25 1.055024959678757678e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.916384712636794578e-20 0.000000000000000000e+00 1.231046756345844236e-20 3.250308528138489804e-19 4.315400231728222934e+03 3.268948974669983280e-19 3.212850250778987032e-19 4.461355100392086737e-20 3.841927029831173849e-31 1.899646470312022230e-21 5.349954059844138782e-27 3.801487188092038683e-25 1.054571469403976565e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.916066528136404898e-20 0.000000000000000000e+00 1.225108326859321097e-20 3.251713043698731261e-19 4.320300231465401339e+03 3.231433970072035764e-19 3.216476573338986171e-19 4.407726637850160385e-20 3.821636404613811870e-31 1.898772826948029385e-21 5.330474576427324589e-27 3.792412322178018397e-25 1.054077671789099434e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.128717494803514915e-20 0.000000000000000000e+00 1.219196945697846339e-20 3.255864328168865514e-19 4.325200231203175463e+03 3.270134066611069612e-19 3.220102920398149352e-19 4.283175921563414283e-20 3.801560817452871612e-31 1.897899183583930088e-21 5.313934000767568774e-27 3.784380350022466655e-25 1.053583874174920077e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.950303007427454770e-20 0.000000000000000000e+00 1.213285564535652969e-20 3.256646652704224176e-19 4.330100230941542577e+03 3.278791082208010850e-19 3.223729291873799776e-19 4.423127287412129764e-20 3.781485230289502291e-31 1.897044576302200587e-21 5.297393434686688556e-27 3.776348377865942376e-25 1.053107860240891687e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.924682839722820831e-20 0.000000000000000000e+00 1.207374183372744146e-20 3.261926339336447213e-19 4.335000230680501772e+03 3.293218908555710133e-19 3.227355687683633306e-19 4.766143733580936904e-20 3.761632010312797611e-31 1.896215345577145685e-21 5.280852878274711421e-27 3.768316405708447854e-25 1.052655553315047880e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.976723358882809009e-20 0.000000000000000000e+00 1.201462802209121074e-20 3.270621630270177667e-19 4.339900230420049411e+03 3.294923006768934077e-19 3.230982107745710290e-19 4.453080762025111446e-20 3.741859070187329468e-31 1.895386114851991477e-21 5.264312331622809211e-27 3.760284433549989060e-25 1.052203246389787871e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.976960852845111531e-20 0.000000000000000000e+00 1.195551421044787966e-20 3.269769380167092037e-19 4.344800230160185492e+03 3.282428002155215817e-19 3.234608551978464225e-19 4.535090145678044766e-20 3.722086130059486562e-31 1.894556884126737588e-21 5.247771794823292382e-27 3.752252461390565075e-25 1.051721706973502645e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.959700662246769369e-20 0.000000000000000000e+00 1.189640039879745122e-20 3.274353242760335338e-19 4.349750239381566644e+03 3.273746118807409610e-19 3.238272032221940256e-19 4.143903728216461005e-20 3.702514820778803685e-31 1.893719190258503959e-21 5.231062455122973116e-27 3.744138514785759712e-25 1.051226706865980672e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.950219812944466546e-20 0.000000000000000000e+00 1.183668327057317764e-20 3.272711191205385648e-19 4.354700229636938275e+03 3.277690275433885965e-19 3.241935522928527599e-19 4.386334766187990359e-20 3.682960552704298562e-31 1.892882404183109351e-21 5.214353189694130666e-27 3.736024599269621706e-25 1.050732243181383894e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.979237770224471429e-20 0.000000000000000000e+00 1.177696637115567534e-20 3.279642889257362232e-19 4.359600229378836957e+03 3.309865575085232337e-19 3.245562039675019723e-19 4.530344379639464324e-20 3.663656333541634910e-31 1.892059503463095858e-21 5.197812683225295344e-27 3.727992627107308576e-25 1.050245984466744365e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.928893611176573502e-20 0.000000000000000000e+00 1.171785255948398193e-20 3.284862030351791960e-19 4.364500229121314078e+03 3.291546183335060705e-19 3.249188580267904085e-19 4.292423378884335909e-20 3.644585677609599861e-31 1.891236602742985315e-21 5.181272186991963006e-27 3.719960654944047704e-25 1.049759725752790385e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.887981104490906290e-20 0.000000000000000000e+00 1.166333754969405021e-20 3.284994880166333313e-19 4.369450238302297294e+03 3.283788936532382573e-19 3.252852157495530140e-19 4.489566792551980040e-20 3.625320386403028425e-31 1.890405303491217375e-21 5.164562888810146541e-27 3.711846708405461703e-25 1.049286444999825567e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.919330450455201152e-20 0.000000000000000000e+00 1.161130466610620149e-20 3.291412653435578389e-19 4.374400228602774405e+03 3.319897377340187251e-19 3.256515744921210436e-19 4.547462694477298569e-20 3.606171970349071085e-31 1.889574007410221125e-21 5.147853665012063590e-27 3.703732792815387858e-25 1.048833011523477070e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.863291390159233452e-20 0.000000000000000000e+00 1.155927198098408087e-20 3.295487254639456300e-19 4.379350237763588666e+03 3.295668714743284198e-19 3.260179370396213197e-19 4.690382661769550376e-20 3.587195730850826700e-31 1.888742708161840113e-21 5.131144388303496191e-27 3.695618846309862177e-25 1.048379576320115218e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.008008126795514376e-20 0.000000000000000000e+00 1.150723909760824092e-20 3.301938171547444242e-19 4.384350237492438282e+03 3.291196346082622663e-19 3.263880019513812877e-19 4.468015055384947157e-20 3.568027848678624705e-31 1.887876852558135817e-21 5.114266374198528247e-27 3.687422956361073948e-25 1.047893000799807787e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.907296232676144707e-20 0.000000000000000000e+00 1.145468072967025892e-20 3.301894811055521978e-19 4.389300227826754963e+03 3.285883649908038663e-19 3.267543679233770683e-19 4.518009726801985427e-20 3.549316826643998062e-31 1.887014354242307755e-21 5.097557182978847925e-27 3.679309040715531004e-25 1.047405502559870510e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.929865315623392119e-20 0.000000000000000000e+00 1.140264804419242656e-20 3.306308733675865407e-19 4.394250236957381276e+03 3.256259483978021517e-19 3.271207376712844606e-19 4.672762165166935418e-20 3.530750705441010552e-31 1.886157212114027711e-21 5.080847939386429490e-27 3.671195094259489043e-25 1.046917363268629430e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.905022241176221544e-20 0.000000000000000000e+00 1.135061516113391367e-20 3.311915589253894705e-19 4.399250236688066252e+03 3.322024751279569343e-19 3.274908098339937726e-19 4.809708417938355804e-20 3.511997083262730164e-31 1.885317517502767729e-21 5.063969958953616324e-27 3.662999204307692284e-25 1.046421180913324734e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.899523328366985822e-20 0.000000000000000000e+00 1.129805679317663776e-20 3.317479079461549930e-19 4.404250236419361499e+03 3.328082950918165085e-19 3.278608844135171346e-19 4.189953432729182810e-20 3.493470429938824106e-31 1.884477822891405056e-21 5.047091990046076136e-27 3.654803314354895436e-25 1.045924998558741322e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.919016654738617484e-20 0.000000000000000000e+00 1.124549842521294760e-20 3.312819032909986760e-19 4.409200226798507174e+03 3.327891525879749048e-19 3.282272599274536689e-19 4.848557679534543746e-20 3.475162639435085505e-31 1.883653345943104057e-21 5.030382843874619586e-27 3.646689398635869401e-25 1.045437808445416672e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.929420974107434182e-20 0.000000000000000000e+00 1.119346573926388834e-20 3.325450144141725782e-19 4.414150235889122996e+03 3.299814181218873735e-19 3.285936391790986834e-19 4.866317032842443044e-20 3.456891376942078372e-31 1.882834547446912053e-21 5.013673646066658617e-27 3.638575452245411760e-25 1.044953973776230194e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.899489257070680287e-20 0.000000000000000000e+00 1.114302285516074651e-20 3.329136430853698573e-19 4.419150235622229047e+03 3.321203634990211404e-19 3.289637209123943089e-19 4.618166767938408640e-20 3.438805046972253466e-31 1.882007479821886731e-21 4.996795712198698005e-27 3.630379562289646330e-25 1.044465252812538487e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.926981187726447696e-20 0.000000000000000000e+00 1.109432863500967067e-20 3.329398124943511925e-19 4.424150235355938094e+03 3.375256187270154390e-19 3.293338050301859652e-19 4.804648989800728613e-20 3.420718717000247790e-31 1.881174960774010341e-21 4.979917790327217584e-27 3.622183672332892749e-25 1.043973310559665709e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.912609441210197872e-20 0.000000000000000000e+00 1.104563441485272225e-20 3.335590840524426514e-19 4.429200244588932946e+03 3.314016251406952019e-19 3.297075931046263803e-19 4.693073300837560733e-20 3.402538984745039954e-31 1.880333292568511207e-21 4.962871069466189852e-27 3.613905807901185385e-25 1.043475961996187798e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.960351626957453971e-20 0.000000000000000000e+00 1.099645315995620252e-20 3.337954987402989498e-19 4.434250234819862271e+03 3.336186948733270991e-19 3.300813821885331055e-19 4.813964671710781654e-20 3.384547940411541537e-31 1.879493194240323654e-21 4.945824425240581465e-27 3.605627974617247488e-25 1.042979541086725346e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.932055101301462797e-20 0.000000000000000000e+00 1.094727209011784647e-20 3.343185475146754801e-19 4.439250234555381212e+03 3.345925407665102177e-19 3.304514734589081005e-19 4.445936450420407155e-20 3.366734991713490832e-31 1.878666126614899228e-21 4.928946540348424230e-27 3.597432084657527162e-25 1.042490820125886047e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.105373094230176848e-20 0.000000000000000000e+00 1.089857786994327127e-20 3.342775286541318728e-19 4.444250234291494053e+03 3.334190883804597098e-19 3.308215670817174001e-19 4.792846117254192052e-20 3.349125611228816271e-31 1.877839058989377000e-21 4.912068667955129680e-27 3.589236194696833380e-25 1.042002099165755806e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.066239799923329469e-20 0.000000000000000000e+00 1.084988364976291227e-20 3.350959763278249111e-19 4.449300243483987288e+03 3.364262041466015349e-19 3.311953647206686865e-19 4.946534366401427665e-20 3.331508293445861411e-31 1.877007422711584238e-21 4.895021997729006116e-27 3.580958330331515272e-25 1.041510678552762302e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.006936588788603430e-20 0.000000000000000000e+00 1.080070239526083202e-20 3.356504615773905371e-19 4.454350233760251285e+03 3.350363168625805334e-19 3.315691633429914247e-19 4.730972134000222044e-20 3.313891041653523392e-31 1.876178319830406413e-21 4.877975404375068156e-27 3.572680496973265929e-25 1.041020754945124019e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.969399601592135435e-20 0.000000000000000000e+00 1.075152132498096856e-20 3.356849300647026728e-19 4.459350233498149464e+03 3.335179863906355287e-19 3.319392640224252295e-19 4.731381456894630325e-20 3.296646197433503219e-31 1.875357424351049867e-21 4.861097570520604857e-27 3.564484607009645349e-25 1.040535681158459033e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.000032910207163386e-20 0.000000000000000000e+00 1.070282710478322202e-20 3.360676054027521879e-19 4.464400242660448384e+03 3.379399023052101567e-19 3.323130687622535948e-19 4.550609755717489964e-20 3.279288594512801681e-31 1.874528318369180126e-21 4.844050939734332122e-27 3.556206742693821524e-25 1.040045755720138386e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.884335554953331173e-20 0.000000000000000000e+00 1.065431886833382110e-20 3.361189710440344950e-19 4.469500242383555815e+03 3.367548993210018859e-19 3.326905762284053594e-19 4.649642579168999925e-20 3.261759178666007700e-31 1.873691004981804261e-21 4.826835576229342887e-27 3.547846934946580552e-25 1.039550980460233374e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.906283366419893321e-20 0.000000000000000000e+00 1.060759369741224818e-20 3.366384428111232060e-19 4.474550232704958944e+03 3.384402427456753297e-19 3.330643843080505674e-19 4.827621728373121029e-20 3.244646925748338812e-31 1.872872724725342525e-21 4.809789036188527041e-27 3.539569101514339808e-25 1.039061056851319351e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.962251418986599447e-20 0.000000000000000000e+00 1.056132670256306559e-20 3.372886734457959701e-19 4.479600241837062640e+03 3.339528780849123157e-19 3.334381961237358225e-19 4.757989810549839251e-20 3.227534609089267616e-31 1.872081305383743944e-21 4.792742446374689615e-27 3.531291237248011182e-25 1.038571131418268304e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.961499312846207437e-20 0.000000000000000000e+00 1.051505953537402954e-20 3.375570693808327037e-19 4.484700241562045449e+03 3.393738115808985895e-19 3.338157107140254220e-19 4.649757800284892207e-20 3.210343029377392920e-31 1.871282051695500150e-21 4.775527124581084270e-27 3.522931429497696477e-25 1.038076356160548019e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.957516831751021590e-20 0.000000000000000000e+00 1.046833436443527372e-20 3.377755260788260994e-19 4.489750231917138990e+03 3.360413520556051190e-19 3.341895258264918447e-19 4.412229644863207773e-20 3.193610011690161280e-31 1.870470332576466046e-21 4.758480626179746555e-27 3.514653596010231376e-25 1.037588768257927118e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.923201199745763142e-20 0.000000000000000000e+00 1.042206736927742625e-20 3.378053895952477617e-19 4.494800241019245732e+03 3.365818898723099946e-19 3.345633446467182481e-19 4.601234842454668687e-20 3.176876931885167196e-31 1.869647368130196960e-21 4.741434078669256017e-27 3.506375731793072852e-25 1.037102471907372676e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.976202150753182989e-20 0.000000000000000000e+00 1.037580020236321590e-20 3.384561030260578709e-19 4.499900240746084819e+03 3.428957531945734385e-19 3.349408662894312255e-19 4.786240352174384031e-20 3.160142036341568667e-31 1.868816257063601009e-21 4.724218799951226463e-27 3.498015924039715177e-25 1.036611361653729154e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.149380281745591809e-20 0.000000000000000000e+00 1.032907503140745471e-20 3.391893777369704175e-19 4.505000240473541453e+03 3.410541110318582710e-19 3.353183902825175699e-19 4.888263954981379722e-20 3.143606544267476575e-31 1.867985145996904623e-21 4.707003536002233058e-27 3.489656116285345475e-25 1.036120251400814439e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.949617450092777438e-20 0.000000000000000000e+00 1.028234986044603461e-20 3.395855205447397267e-19 4.510100240201615634e+03 3.423611864289232687e-19 3.356959166180476981e-19 4.846909532267579855e-20 3.127071052191382378e-31 1.867154034930107051e-21 4.689788286984941579e-27 3.481296308529963287e-25 1.035629141148629095e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.963368659083137333e-20 0.000000000000000000e+00 1.023562468947895708e-20 3.399055899649049591e-19 4.515200239930302814e+03 3.419203205116627725e-19 3.360734452881274159e-19 4.772455063336706408e-20 3.110621355798685620e-31 1.866322923863209797e-21 4.672573053064427762e-27 3.472936500773575959e-25 1.035138030897175190e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.986436024848144154e-20 0.000000000000000000e+00 1.018915200012122741e-20 3.401851843623875414e-19 4.520300239659602994e+03 3.452370379235081466e-19 3.364509762848980624e-19 4.721094164658280653e-20 3.094214548158893548e-31 1.865491812796212861e-21 4.655357834408198120e-27 3.464576693016184411e-25 1.034646920646453289e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.959501660143694193e-20 0.000000000000000000e+00 1.014796590012898915e-20 3.404697180305656819e-19 4.525450248870271025e+03 3.446919920622832866e-19 3.368322116210265182e-19 4.398982364031575575e-20 3.077646858953509987e-31 1.864652552035955739e-21 4.638824198810015951e-27 3.456451900986908152e-25 1.034150994676881011e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.939366658725249558e-20 0.000000000000000000e+00 1.010637593825253516e-20 3.404024719435215511e-19 4.530600239114754913e+03 3.421924178063581723e-19 3.372134479096498687e-19 4.431070567471100530e-20 3.061501070404765590e-31 1.863817608378495651e-21 4.624371575171226860e-27 3.449102839602540187e-25 1.033631147417712193e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.988382009724826627e-20 0.000000000000000000e+00 1.006478612954141371e-20 3.408482895945692802e-19 4.535700238845890453e+03 3.422809733381963499e-19 3.375909858847774904e-19 4.936312022037360671e-20 3.045551980336487110e-31 1.862992608421988231e-21 4.610059251295523989e-27 3.441825114926358573e-25 1.033106148339915784e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.962561341585964153e-20 0.000000000000000000e+00 1.002360002953435331e-20 3.418984742550618433e-19 4.540850248026244117e+03 3.470861734004074878e-19 3.379722282415527800e-19 4.751472561895288224e-20 3.029461483591771054e-31 1.862161358760653767e-21 4.595606593560861902e-27 3.434476026520411104e-25 1.032577841296153082e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.975938306932492088e-20 0.000000000000000000e+00 9.982010067902709087e-21 3.420197126183270814e-19 4.546000238304731283e+03 3.464974356085539704e-19 3.383534715317925617e-19 4.722927918532777900e-20 3.013474753206157381e-31 1.861366139673534089e-21 4.581153998575391179e-27 3.427126965087520477e-25 1.032085563654109925e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.956131713571297728e-20 0.000000000000000000e+00 9.940420258916986138e-21 3.423443638759416008e-19 4.551150247464919630e+03 3.493960226539497010e-19 3.387347185446608885e-19 4.465294516293925826e-20 2.997487964207487840e-31 1.860570917670858154e-21 4.566701360397921649e-27 3.419777876710349202e-25 1.031593284208003426e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.979470315490016992e-20 0.000000000000000000e+00 9.898830297448191329e-21 3.423878474514889764e-19 4.556300237766017744e+03 3.509689613347784443e-19 3.391159664784258107e-19 4.756640210118916731e-20 2.981667616072511949e-31 1.859762735541223467e-21 4.552248785034966501e-27 3.412428815245192632e-25 1.031087141773480768e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.982316289456443234e-20 0.000000000000000000e+00 9.857240488279870661e-21 3.431571741416459884e-19 4.561450246906130815e+03 3.499721281326812452e-19 3.394972181160293759e-19 4.687709557657792154e-20 2.966131755166504837e-31 1.858935726774197862e-21 4.537796166787675807e-27 3.405079726896668981e-25 1.030560864368328828e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.166598580331055384e-20 0.000000000000000000e+00 9.815650526973197024e-21 3.435492727865433820e-19 4.566600237229734375e+03 3.529746648371966307e-19 3.398784706620881255e-19 4.705349696602778168e-20 2.950595951023634679e-31 1.858108721028801738e-21 4.523343611425526732e-27 3.397730665399396620e-25 1.030034588886949189e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.998525433412850190e-20 0.000000000000000000e+00 9.774060717623128755e-21 3.438471500382581832e-19 4.571750246349859481e+03 3.552149748975522111e-19 3.402597268933496420e-19 4.776209890456518293e-20 2.935129892043777816e-31 1.857281712264985890e-21 4.508891013490995095e-27 3.390381577079396155e-25 1.029536415425394178e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.990803300566908155e-20 0.000000000000000000e+00 9.734850891065955179e-21 3.443159978537691963e-19 4.576950246069975037e+03 3.533075819165792569e-19 3.406446862583505930e-19 4.549089175143916901e-20 2.919566256517837815e-31 1.856446675813580827e-21 4.494298136125036471e-27 3.382961151927570293e-25 1.029042985642431550e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.977346062132256016e-20 0.000000000000000000e+00 9.695639141275340759e-21 3.443802026765374232e-19 4.582150245790724512e+03 3.552536902219613059e-19 3.410296479461049090e-19 4.568728632883489922e-20 2.904002620990000368e-31 1.855616266944889946e-21 4.479705269335109719e-27 3.375540726774839850e-25 1.028545946933917804e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.958753095518488538e-20 0.000000000000000000e+00 9.656427391479947625e-21 3.447752428580589015e-19 4.587350245512108813e+03 3.470987586752820526e-19 3.414146119487556142e-19 4.474718662676412781e-20 2.888716225639548792e-31 1.854824962639461596e-21 4.465112413224923661e-27 3.368120301621203910e-25 1.028018411638061220e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.961567916245881209e-20 0.000000000000000000e+00 9.617215641679766750e-21 3.450333474701294483e-19 4.592550245234122485e+03 3.525227834468591310e-19 3.417995782584808814e-19 4.964055727322756143e-20 2.873491782008986134e-31 1.854033658333937702e-21 4.450519567899566085e-27 3.360699876466669359e-25 1.027490876343072433e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.943578522807640662e-20 0.000000000000000000e+00 9.578003891874838759e-21 3.460709720685582347e-19 4.597750244956765528e+03 3.499761009191089594e-19 3.421845468674942237e-19 5.289126713294323965e-20 2.858282746179091511e-31 1.853222588401103209e-21 4.435926733465490117e-27 3.353279451311237116e-25 1.026978755725346481e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.978894210770083670e-20 0.000000000000000000e+00 9.538792142065166660e-21 3.469507604236536600e-19 4.602950244680036121e+03 3.507094185861451786e-19 3.425695177680441585e-19 4.726936927435087444e-20 2.843378471110186246e-31 1.852387551949191085e-21 4.421333910030559415e-27 3.345859026154909018e-25 1.026485325946311697e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.979987308600911413e-20 0.000000000000000000e+00 9.499580392250760987e-21 3.465184407634825112e-19 4.608150244403930628e+03 3.474144057122686816e-19 3.429544909524135808e-19 4.739566983166202307e-20 2.828474196039493013e-31 1.851552515497178903e-21 4.406741097704071853e-27 3.338438600997690575e-25 1.025991896168036564e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.927544149965663040e-20 0.000000000000000000e+00 9.460368642431651832e-21 3.468856504804984843e-19 4.613350244128447230e+03 3.460805534710858029e-19 3.433394664129204373e-19 4.642378609991084442e-20 2.813625793137848490e-31 1.850757876786349783e-21 4.392148296596773863e-27 3.331018175839584542e-25 1.025473692127958584e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.974522436446659099e-20 0.000000000000000000e+00 9.421156892607851232e-21 3.471602887659822023e-19 4.618550243853584107e+03 3.471678257087239146e-19 3.437244441419166679e-19 4.907845350608855242e-20 2.798936690466013896e-31 1.849972265317084226e-21 4.377555506820886271e-27 3.323597750680593215e-25 1.024949952055085940e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.999634666326707489e-20 0.000000000000000000e+00 9.381945142779372728e-21 3.479188638082961240e-19 4.623800253038619303e+03 3.501095608529617768e-19 3.441131265739211887e-19 4.681163401419756392e-20 2.784106319692286554e-31 1.849173341245686368e-21 4.362822386816810330e-27 3.316105961776595932e-25 1.024421175067854563e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.949858295595554376e-20 0.000000000000000000e+00 9.343785579816902958e-21 3.479614100826562610e-19 4.629050243300455804e+03 3.438210464656511084e-19 3.445018099016662414e-19 4.631088095056660498e-20 2.769381529682317482e-31 1.848342407535179626e-21 4.348089331703625664e-27 3.308614199876096202e-25 1.023892399987499965e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.961929336475231040e-20 0.000000000000000000e+00 9.306305331508674121e-21 3.482846299169812427e-19 4.634250243027452598e+03 3.472094350570498624e-19 3.448867944336979035e-19 4.870404782726904558e-20 2.754907599407725218e-31 1.847519385995654725e-21 4.333496576836160775e-27 3.301193774714450829e-25 1.023368659917243313e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.948644381630828422e-20 0.000000000000000000e+00 9.269181971035548301e-21 3.489829295079283846e-19 4.639500252182340773e+03 3.510357082129116402e-19 3.452754837086822207e-19 4.782768760316275526e-20 2.740294470477291489e-31 1.846707156145113947e-21 4.318763492523926023e-27 3.293701985853473425e-25 1.022839882935883013e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.988537243138325833e-20 0.000000000000000000e+00 9.231701587847779936e-21 3.492674565881099348e-19 4.644750242478060500e+03 3.540569714748032035e-19 3.456641738610053388e-19 4.781498699298098499e-20 2.725896736258437852e-31 1.845913992143602353e-21 4.304030473287195568e-27 3.286210223904621848e-25 1.022311107854954585e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.921411527069916696e-20 0.000000000000000000e+00 9.194221339297655803e-21 3.496114450678032458e-19 4.650000251612897046e+03 3.481485905770240275e-19 3.460528676740497173e-19 4.781435896359041603e-20 2.711585067521007141e-31 1.845120825295893559e-21 4.289297413458687217e-27 3.278718435072258548e-25 1.021782330877516863e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.979581877249833549e-20 0.000000000000000000e+00 9.156740956253038200e-21 3.500270975288129101e-19 4.655300251326439138e+03 3.496792369924790581e-19 3.464452649196217241e-19 5.026275621797994770e-20 2.697137123096420216e-31 1.844287730005887580e-21 4.274424078039141572e-27 3.271155309438443522e-25 1.021280894739845150e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.043277105237138921e-20 0.000000000000000000e+00 9.118903685060156858e-21 3.507930489578649175e-19 4.660550241656022081e+03 3.534972568244291726e-19 3.468339618708054355e-19 4.868573330491072237e-20 2.683028940211228825e-31 1.843456796284658449e-21 4.259691096038791184e-27 3.263663547441269025e-25 1.020789889306966720e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.000030255187227912e-20 0.000000000000000000e+00 9.081423436268278864e-21 3.509287996635441182e-19 4.665800250760848940e+03 3.544193152537256197e-19 3.472226624551556942e-19 4.721745225137098339e-20 2.668933025354432739e-31 1.842634962385872764e-21 4.244958074013405577e-27 3.256171758651729076e-25 1.020291758205619800e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.032088095129661935e-20 0.000000000000000000e+00 9.043943053437904416e-21 3.511299368141808021e-19 4.671100250476327346e+03 3.516560029432693415e-19 3.476150665158225836e-19 4.733494797048418168e-20 2.654756076980527684e-31 1.841839962428550926e-21 4.230084777064877845e-27 3.248608633015151179e-25 1.019761759160895726e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.025278007938760833e-20 0.000000000000000000e+00 9.006105782231198507e-21 3.515288737772065470e-19 4.676400250192449676e+03 3.624981861055295242e-19 3.480074728471778257e-19 5.132428792399443238e-20 2.640839070923226838e-31 1.841044962471132416e-21 4.215211493293471028e-27 3.241045507377654009e-25 1.019231760117070859e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.079008731381708709e-20 0.000000000000000000e+00 8.970323171232132346e-21 3.525060373904771995e-19 4.681700249909214108e+03 3.525981553113380877e-19 3.483998814415491896e-19 4.827104344862724908e-20 2.626922064864239617e-31 1.840253154268840530e-21 4.200338222839189777e-27 3.233482381739240779e-25 1.018703888907231748e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.468708646322195011e-20 0.000000000000000000e+00 8.936665978379323122e-21 3.527127890371231169e-19 4.687000249626620644e+03 3.553471953500419933e-19 3.487922922912985815e-19 4.762843391435812651e-20 2.613079353348181968e-31 1.839463792608801225e-21 4.185464965844020377e-27 3.225919256099911032e-25 1.018177648723657601e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.071740688253542425e-20 0.000000000000000000e+00 8.903008785522436343e-21 3.527568932072021694e-19 4.692300249344664735e+03 3.581887884301610052e-19 3.491847053888222856e-19 5.018378622455009430e-20 2.599349830269058724e-31 1.838674430948667128e-21 4.170591722451992455e-27 3.218356130459671654e-25 1.017651408540974949e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.004101410196766878e-20 0.000000000000000000e+00 8.869351592661499093e-21 3.534587597717383322e-19 4.697600249063345473e+03 3.524967331288005795e-19 3.495771207265507714e-19 5.076172614413783199e-20 2.585620307188286765e-31 1.837851024968839946e-21 4.155718492809181847e-27 3.210793004818523563e-25 1.017125168359185108e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.127762036691853909e-20 0.000000000000000000e+00 8.835694399796520399e-21 3.540001907354067962e-19 4.702900248782659219e+03 3.569999111766533138e-19 3.499695382969480675e-19 4.951879767193453197e-20 2.572073423356394173e-31 1.837024074658024822e-21 4.140845277063773735e-27 3.203229879176472730e-25 1.016598928178290335e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.121694005028986692e-20 0.000000000000000000e+00 8.802037206927521326e-21 3.542073285431528257e-19 4.708250257969160884e+03 3.595760029199127060e-19 3.503656608777419433e-19 4.841899194289817277e-20 2.558510427094397455e-31 1.836198897749273885e-21 4.125831735636835027e-27 3.195595389779012816e-25 1.016058146247317664e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.051471612271083238e-20 0.000000000000000000e+00 8.768062433233700154e-21 3.544046156586318721e-19 4.713600248217916487e+03 3.603369482324964257e-19 3.507617843159731675e-19 4.861382775596354405e-20 2.544947478842145979e-31 1.835402090690948595e-21 4.110818261826879813e-27 3.187960927405809869e-25 1.015488999352148813e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.051492718059866323e-20 0.000000000000000000e+00 8.734087779802407687e-21 3.548220399454158809e-19 4.718900247939131987e+03 3.607291746850139016e-19 3.511542085811312692e-19 4.497367872309625687e-20 2.531681542984436842e-31 1.834612729030342043e-21 4.095945088956653831e-27 3.180397801761044838e-25 1.014925170589939218e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.008566054224299288e-20 0.000000000000000000e+00 8.700430586921332432e-21 3.547047181967185911e-19 4.724250257095475718e+03 3.571141718480832523e-19 3.515503378947179635e-19 4.921195517044801577e-20 2.518320979577784051e-31 1.833819328176021151e-21 4.080931591373253771e-27 3.172763312406620874e-25 1.014381345789571623e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.076237512292335839e-20 0.000000000000000000e+00 8.666455813419025432e-21 3.556965450291065408e-19 4.729600247378207314e+03 3.583300717601822695e-19 3.519464680476999906e-19 5.072613113226987557e-20 2.504981139969001041e-31 1.833028132429983258e-21 4.065918161709686278e-27 3.165128849984933836e-25 1.013853882892048737e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.956684399976541689e-20 0.000000000000000000e+00 8.633104990072472000e-21 3.562319981819573836e-19 4.734950256514493049e+03 3.742770803120979850e-19 3.523426018259713189e-19 4.901873544128467779e-20 2.491896956551132118e-31 1.832236933895744234e-21 4.050904694260240309e-27 3.157494360659132242e-25 1.013326418136699724e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.999535570258879774e-20 0.000000000000000000e+00 8.601176937932380589e-21 3.564075250368033577e-19 4.740350256222283861e+03 3.585828562339583168e-19 3.527424393376645700e-19 5.123992288984096757e-20 2.478690514312750288e-31 1.831402072979646312e-21 4.036913280480697253e-27 3.150242341473728291e-25 1.012794024743171238e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.127532878222679980e-20 0.000000000000000000e+00 8.568950549559048897e-21 3.571879120593866835e-19 4.745700246538965985e+03 3.594233304625161847e-19 3.531385761792357121e-19 4.831929785618576303e-20 2.465666520414893133e-31 1.830573201240441853e-21 4.024430931787737285e-27 3.143596074298606063e-25 1.012266561845229311e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.051968852041256833e-20 0.000000000000000000e+00 8.537022609731528748e-21 3.571273198526859811e-19 4.751050255645236575e+03 3.597518566751878149e-19 3.535347166188825246e-19 4.677103959742980032e-20 2.452783411238182398e-31 1.829755948108802819e-21 4.011948548470613455e-27 3.136949783781268690e-25 1.011739097095772440e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.028985889555058889e-20 0.000000000000000000e+00 8.505094557770563869e-21 3.572991920368482465e-19 4.756450255355002810e+03 3.608402787817373961e-19 3.539345608338701843e-19 5.027459993570682846e-20 2.439779922004194775e-31 1.828957356602429096e-21 3.999349538919684516e-27 3.130241390178241223e-25 1.011206703705013983e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.054043387430672600e-20 0.000000000000000000e+00 8.472868169385441874e-21 3.581832984579660614e-19 4.761850255065426609e+03 3.636459486446033051e-19 3.543344072820215703e-19 4.767900113850206653e-20 2.426868253066033598e-31 1.828158765095957949e-21 3.986750538932819114e-27 3.123532996574396880e-25 1.010674310315188209e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.038977128041904119e-20 0.000000000000000000e+00 8.440641780996395798e-21 3.582143355131661805e-19 4.767250254776506154e+03 3.600047240529711306e-19 3.547342559557850629e-19 4.923580547543454557e-20 2.414038723551119349e-31 1.827363948599254435e-21 3.974151548600993940e-27 3.116824602969737956e-25 1.010118907383391091e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.038919229438440117e-20 0.000000000000000000e+00 8.408415392603436172e-21 3.588193655594079844e-19 4.772650254488240535e+03 3.607330220095241352e-19 3.551341068476433244e-19 4.941974674193168821e-20 2.401209194034649220e-31 1.826570941648579990e-21 3.961552568016345107e-27 3.110116209364265369e-25 1.009552474857824513e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.027153536578712979e-20 0.000000000000000000e+00 8.376189004206569014e-21 3.592325103056955798e-19 4.778050254200626114e+03 3.593739510269339712e-19 3.555339599501125279e-19 4.981851721035305992e-20 2.388664181698687356e-31 1.825778087929075552e-21 3.948953597272190394e-27 3.103407815757983712e-25 1.008987195214116322e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.025901533955382071e-20 0.000000000000000000e+00 8.343962615805815390e-21 3.596813621393127924e-19 4.783450253913661072e+03 3.649043102884692274e-19 3.559338152557425505e-19 5.180485656072708414e-20 2.376204844612453022e-31 1.824990587970924371e-21 3.936354636463035702e-27 3.096699422150895739e-25 1.008462196180783880e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.066079162781650616e-20 0.000000000000000000e+00 8.311932054206935806e-21 3.603788674682404734e-19 4.788850253627343591e+03 3.642150827624847372e-19 3.563336727571167806e-19 4.779979121104010840e-20 2.363745507524724992e-31 1.824203088012679150e-21 3.923755685684603033e-27 3.089991028543003287e-25 1.007937197148366255e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.071219883824296551e-20 0.000000000000000000e+00 8.281264805102026012e-21 3.602227429831122773e-19 4.794250253341670032e+03 3.602392289297593369e-19 3.567335324468513951e-19 4.812367316267049662e-20 2.351373419678681341e-31 1.823413599159614994e-21 3.911156745033851300e-27 3.083282634934310489e-25 1.007397234078620704e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.126936135239545016e-20 0.000000000000000000e+00 8.250597555993458457e-21 3.606930812608996873e-19 4.799700262516400471e+03 3.628572121811197563e-19 3.571370974531711690e-19 5.097968915041048078e-20 2.338889265329098716e-31 1.822613248161927203e-21 3.898441135816837869e-27 3.076512114814081540e-25 1.006825555820072380e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.336422429537060833e-20 0.000000000000000000e+00 8.219646297132829460e-21 3.616125278003648148e-19 4.805150252766989979e+03 3.623802245228088698e-19 3.575406632721980868e-19 4.796247180196572867e-20 2.326459167963866052e-31 1.821812899943309302e-21 3.885725581272321395e-27 3.069741618203221654e-25 1.006253879547735795e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.041152410263251997e-20 0.000000000000000000e+00 8.188695145744678062e-21 3.614190658889853959e-19 4.810550252483250915e+03 3.651392730161941231e-19 3.579405295230926135e-19 4.907913023543313775e-20 2.314343142110428153e-31 1.821027894467943252e-21 3.873126671793001550e-27 3.063033224592125980e-25 1.005720405430741278e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.079097394514602481e-20 0.000000000000000000e+00 8.158027896625125182e-21 3.619852612094980551e-19 4.816000261627899818e+03 3.640770016955085199e-19 3.583441011266684637e-19 5.165756913212687040e-20 2.302114909671971102e-31 1.820238582798717946e-21 3.860411094419326522e-27 3.056262704509267190e-25 1.005194198598311284e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.060668391470878606e-20 0.000000000000000000e+00 8.127076637935333695e-21 3.627313161853118993e-19 4.821500261329455498e+03 3.663651923371260032e-19 3.587513767385001472e-19 5.193211274513493255e-20 2.289892058029564202e-31 1.819441628556121319e-21 3.847578893584000565e-27 3.049430081398595792e-25 1.004660117139587913e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.091016855073857574e-20 0.000000000000000000e+00 8.095841476848718884e-21 3.631894714248541019e-19 4.826950251625416058e+03 3.634664220111465197e-19 3.591549513423819650e-19 5.240600906152779279e-20 2.277930763537902970e-31 1.818646838304626761e-21 3.834863382063196503e-27 3.042659584731371412e-25 1.004092410841035348e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.043245549738739392e-20 0.000000000000000000e+00 8.064890325202900628e-21 3.636282610456735965e-19 4.832400260739997975e+03 3.661002525928364823e-19 3.595585295167032733e-19 4.987909819827905754e-20 2.265969427744320442e-31 1.817852045308750118e-21 3.822147837688090153e-27 3.035889064685864873e-25 1.003524702583372111e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.003327284560100328e-20 0.000000000000000000e+00 8.033939066683862391e-21 3.636487981983448597e-19 4.837900260443574552e+03 3.681070033993203176e-19 3.599658117395092876e-19 4.987170086199769392e-20 2.253960492491077501e-31 1.817052376073689110e-21 3.809315670411698722e-27 3.029056441572682692e-25 1.002970064795539742e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.018011814620720575e-20 0.000000000000000000e+00 8.002703905585771746e-21 3.640579078041401389e-19 4.843350250773390144e+03 3.664348074783463760e-19 3.603693928744788252e-19 5.117517820407909655e-20 2.242093228779531725e-31 1.816263067129371052e-21 3.796600192404959654e-27 3.022285944863400410e-25 1.002443859784913274e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.993531075761640888e-20 0.000000000000000000e+00 7.974786723974647643e-21 3.646235260217690666e-19 4.848800259858102436e+03 3.636029122479736147e-19 3.607729775532570569e-19 5.318788985544560172e-20 2.230225924229508648e-31 1.815473755468826725e-21 3.783884682030246800e-27 3.015515424855000922e-25 1.001917652964472946e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.991833284309510528e-20 0.000000000000000000e+00 7.947052057233754468e-21 3.653084838374242912e-19 4.854300259563678992e+03 3.656416241576995476e-19 3.611802663204253112e-19 5.289842397681542313e-20 2.218542979747502571e-31 1.814681469514813529e-21 3.771052549337931602e-27 3.008682801739334131e-25 1.001360009507134917e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.990384818756274060e-20 0.000000000000000000e+00 7.919062992162824376e-21 3.656673331877851113e-19 4.859800259269921298e+03 3.691010285618720632e-19 3.615875572675892512e-19 5.037176770460109966e-20 2.206895921546048394e-31 1.813890373666655399e-21 3.758220428480770325e-27 3.001850178622840363e-25 1.000794942070076860e-21 0.000000000000000000e+00 0.000000000000000000e+00 2.089278279827185791e-20 0.000000000000000000e+00 7.891073927088507356e-21 3.657676116909490127e-19 4.865300258976829355e+03 3.673184684705400534e-19 3.619948503873906207e-19 4.729498793276508238e-20 2.195267694997359701e-31 1.813099277818401348e-21 3.745388319580427067e-27 2.995017555505519156e-25 1.000229874634109286e-21 0.000000000000000000e+00 0.000000000000000000e+00 1.962314915051826211e-20 0.000000000000000000e+00 7.863084862010801903e-21 3.656887631108774513e-19 4.870800258684398614e+03 3.667811459395685634e-19 3.624021456725040970e-19 5.100888840221514732e-20 2.183793185803529047e-31 1.812308181970052129e-21 3.732556222760244072e-27 2.988184932387376940e-25 9.996648071992350155e-22 0.000000000000000000e+00 0.000000000000000000e+00 1.977885217161198368e-20 0.000000000000000000e+00 7.835095796929730586e-21 3.665980051694233770e-19 4.876300258392627256e+03 3.656917905214174345e-19 3.628094431156372427e-19 4.897133009799730684e-20 2.172318676608322493e-31 1.811517086121608494e-21 3.719724138145263978e-27 2.981352309268415551e-25 9.990997397654561177e-22 0.000000000000000000e+00 0.000000000000000000e+00 1.980670663290408473e-20 0.000000000000000000e+00 7.807106731845303939e-21 3.667239009433969416e-19 4.881850267572736811e+03 3.653257835796667536e-19 3.632204461445381057e-19 5.238891265763312402e-20 2.160793044235963669e-31 1.810718797129948783e-21 3.706775388613135043e-27 2.974457559623660091e-25 9.985313496312279701e-22 0.000000000000000000e+00 0.000000000000000000e+00 1.936142403962032935e-20 0.000000000000000000e+00 7.778863172499502482e-21 3.675776678302040772e-19 4.887400257805779802e+03 3.706973869367920384e-19 3.636314499528870839e-19 4.832735422373036958e-20 2.149373848645362825e-31 1.809920510863552165e-21 3.693826695977314671e-27 2.967562833516754179e-25 9.979649475525761644e-22 0.000000000000000000e+00 0.000000000000000000e+00 1.950251558648280347e-20 0.000000000000000000e+00 7.750619709573829405e-21 3.674344247992676439e-19 4.892900257515985686e+03 3.666320442350720856e-19 3.640387538654265762e-19 4.830897939966197241e-20 2.138057509372338015e-31 1.809129415014824154e-21 3.680994648975795497e-27 2.960730210395336191e-25 9.974036472383043254e-22 0.000000000000000000e+00 0.000000000000000000e+00 1.930010932083603449e-20 0.000000000000000000e+00 7.722630644479341279e-21 3.678238339392383218e-19 4.898450266665979143e+03 3.694820978350134648e-19 3.644497633981683540e-19 5.042377045092838434e-20 2.126778554113938122e-31 1.808335676190574533e-21 3.668045937872863451e-27 2.953835460787994053e-25 9.968404716745610606e-22 0.000000000000000000e+00 0.000000000000000000e+00 1.910687228832503837e-20 0.000000000000000000e+00 7.695555620101955679e-21 3.685033847623984327e-19 4.904000256933109995e+03 3.706632378605295182e-19 3.648607736930792368e-19 5.387613116571909206e-20 2.115606495783999096e-31 1.807542820438127283e-21 3.655097283922570057e-27 2.946940734638740956e-25 9.962779226713035747e-22 0.000000000000000000e+00 0.000000000000000000e+00 1.932613726627761560e-20 0.000000000000000000e+00 7.668870998161485025e-21 3.694084360625151707e-19 4.909550266063073650e+03 3.687569944129923669e-19 3.652717875381627123e-19 5.115699124127323061e-20 2.104434399483422841e-31 1.806758072153638632e-21 3.642148599200316986e-27 2.940045985056281187e-25 9.957153814122049410e-22 0.000000000000000000e+00 0.000000000000000000e+00 1.939525501997148689e-20 0.000000000000000000e+00 7.642186285527601065e-21 3.694311184465046684e-19 4.915100256352864562e+03 3.669600901670517228e-19 3.656828021340082505e-19 5.031822778232868043e-20 2.093388062717952016e-31 1.806008073465829010e-21 3.629199971812386182e-27 2.933151258878877756e-25 9.951528834292069329e-22 0.000000000000000000e+00 0.000000000000000000e+00 1.999907058484180365e-20 0.000000000000000000e+00 7.615501663478179952e-21 3.697540351478092581e-19 4.920650265462889365e+03 3.701115545913282439e-19 3.660938202623976705e-19 5.023251800623703481e-20 2.082374538146370580e-31 1.805258072234744638e-21 3.616251314037368222e-27 2.926256509321187857e-25 9.945903835399244062e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.110408265722251098e-20 0.000000000000000000e+00 7.588816950940162164e-21 3.702096861427391507e-19 4.926250265161120296e+03 3.736850079423967487e-19 3.665085427141691665e-19 5.355469883189766163e-20 2.071268000861100982e-31 1.804478533548411427e-21 3.603186037691509886e-27 2.919299656696802659e-25 9.940187759673148735e-22 0.000000000000000000e+00 0.000000000000000000e+00 1.976925207744616020e-20 0.000000000000000000e+00 7.561891881233456141e-21 3.710106028163541837e-19 4.931850264860036077e+03 3.716352252490386142e-19 3.669232673287906604e-19 5.267725177310880587e-20 2.060385936930046942e-31 1.803678533591423561e-21 3.590120775411328963e-27 2.912342804071566147e-25 9.934435389628785222e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.007214235376929513e-20 0.000000000000000000e+00 7.534966811523456477e-21 3.713104951001599471e-19 4.937400255195035243e+03 3.705009557921359419e-19 3.673342904781035677e-19 5.120457936314891479e-20 2.049601052485519283e-31 1.802885677829280833e-21 3.577172203142738659e-27 2.905448077838000718e-25 9.928734389664821030e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.002861532294492633e-20 0.000000000000000000e+00 7.508282189256671600e-21 3.715079350922593267e-19 4.942950264265260557e+03 3.706357064689317373e-19 3.677453171249761764e-19 5.310660715538881280e-20 2.038854461716585699e-31 1.802102311747849391e-21 3.564223601284226308e-27 2.898553328329753672e-25 9.923068401721353005e-22 0.000000000000000000e+00 0.000000000000000000e+00 1.991043396261487883e-20 0.000000000000000000e+00 7.481597476910013008e-21 3.721741016217858278e-19 4.948550263966205421e+03 3.724640293261503263e-19 3.681600481461580340e-19 5.132716272549340587e-20 2.028131365515034406e-31 1.801313050045031436e-21 3.551158381874090465e-27 2.891596475701996734e-25 9.917355660910617613e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.010426689732345112e-20 0.000000000000000000e+00 7.454672407190257304e-21 3.723443038920146289e-19 4.954150263667827858e+03 3.743725957609674082e-19 3.685747813012139846e-19 4.695020585544352321e-20 2.017408269312186037e-31 1.800522597722808068e-21 3.538093177157052861e-27 2.884639623073398124e-25 9.911634302311367893e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.046189380065635675e-20 0.000000000000000000e+00 7.428414547839576243e-21 3.721958973018962547e-19 4.959800272860457881e+03 3.750706684505151119e-19 3.689932202891439978e-19 4.969935411214396224e-20 2.006698719330783273e-31 1.799720907229259412e-21 3.524911311735239373e-27 2.877620643895244386e-25 9.905831600920822874e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.094158873855965590e-20 0.000000000000000000e+00 7.402453381292420675e-21 3.729927467443543217e-19 4.965450263067791639e+03 3.787875144938670746e-19 3.694116600284394194e-19 4.982136359444115146e-20 1.996108609480626614e-31 1.798919219429569907e-21 3.513109162531477078e-27 2.871164920025579239e-25 9.900028919041259103e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.079757580930771220e-20 0.000000000000000000e+00 7.376492301980598976e-21 3.734143956113212690e-19 4.971050262771440430e+03 3.766707512104152550e-19 3.698263995797309195e-19 5.147819404643861747e-20 1.985612199779684823e-31 1.798150300299135505e-21 3.502249772145511836e-27 2.865108553717508699e-25 9.894278186378448567e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.065865863777766050e-20 0.000000000000000000e+00 7.350760923497165039e-21 3.740409021260230190e-19 4.976650262475754971e+03 3.832351571756687972e-19 3.702411412361817639e-19 5.329470339163801118e-20 1.975263594280205375e-31 1.797398622486475912e-21 3.491390390807442266e-27 2.859052187408718629e-25 9.888527861805148801e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.040368969024039258e-20 0.000000000000000000e+00 7.325029545010672184e-21 3.746905431899856226e-19 4.982300271628223527e+03 3.884207421649005716e-19 3.706595887692820955e-19 5.438263627098954501e-20 1.964884851352995172e-31 1.796640231996211879e-21 3.480434041637544796e-27 2.852941736179765509e-25 9.882726185356281824e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.126163637473561947e-20 0.000000000000000000e+00 7.299068378648053807e-21 3.753072608595481633e-19 4.987950261881127517e+03 4.124473651394516923e-19 3.710780370311017883e-19 5.334581398658971206e-20 1.954506143143201839e-31 1.795850963336642314e-21 3.469477738502977842e-27 2.846831305390578157e-25 9.876925485866493062e-22 0.000000000000000000e+00 0.000000000000000000e+00 1.997410056694156477e-20 0.000000000000000000e+00 7.273107299126841393e-21 3.755006642302042701e-19 4.993600271013557176e+03 3.909326951743420318e-19 3.714964888124347616e-19 5.078075126758763630e-20 1.944212839949677414e-31 1.795059962058101961e-21 3.458521408232786738e-27 2.840720854183296836e-25 9.871124820649030150e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.040339417045693207e-20 0.000000000000000000e+00 7.247146132856300523e-21 3.755813389286193280e-19 4.999250261289186710e+03 5.008952948008888396e-19 3.719149413112876209e-19 5.226120859827028533e-20 1.933926960217121403e-31 1.794268963419513904e-21 3.447565124094473238e-27 2.834610423369532469e-25 9.865324174803911622e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.049386963426057576e-20 0.000000000000000000e+00 7.221185053230666595e-21 3.762024645696698873e-19 5.004900270401665693e+03 4.161736145658035588e-19 3.723333973122192318e-19 5.007750319259712918e-20 1.923684584098313861e-31 1.793477962143766901e-21 3.436608813085176071e-27 2.828499972183827898e-25 9.859523509632413360e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.008844627797363811e-20 0.000000000000000000e+00 7.195223887051796981e-21 3.762969846624211400e-19 5.010600270094060761e+03 4.043584020121546958e-19 3.727555578877623428e-19 5.044097639983037897e-20 1.913583318820651978e-31 1.792679962186831269e-21 3.425555571874439787e-27 2.822335456483846554e-25 9.853671520907819743e-22 0.000000000000000000e+00 0.000000000000000000e+00 1.952018160761078133e-20 0.000000000000000000e+00 7.170025510552840235e-21 3.767328356304400597e-19 5.016250260403681750e+03 3.970608697434593746e-19 3.731740167072672938e-19 5.154113060685929089e-20 1.903570677765627564e-31 1.791913298612842418e-21 3.414599317007341854e-27 2.816225025633320438e-25 9.847846540042539081e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.014963538578228587e-20 0.000000000000000000e+00 7.146622298882978853e-21 3.773282359700845680e-19 5.021900269486310208e+03 3.969252452458937706e-19 3.735924790028888349e-19 5.240487325345104785e-20 1.893593157513203619e-31 1.791159964068491962e-21 3.403643035675562730e-27 2.810114574479898799e-25 9.842008208283782073e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.005606122309024585e-20 0.000000000000000000e+00 7.123219009452158231e-21 3.778554933495433232e-19 5.027600269180781652e+03 3.884823781843005789e-19 3.740146459097597562e-19 5.080492929477485807e-20 1.883587298176921266e-31 1.790399962564262462e-21 3.392589824632360042e-27 2.803950058777672077e-25 9.836118219729031272e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.002323128939923654e-20 0.000000000000000000e+00 7.099608650485576388e-21 3.780523818920200674e-19 5.033300268875946131e+03 3.848729248104232865e-19 3.744368149251954030e-19 4.763211021765103934e-20 1.873581438839422192e-31 1.789607247374868421e-21 3.381536623901906187e-27 2.797785543074695978e-25 9.830229489403119169e-22 0.000000000000000000e+00 0.000000000000000000e+00 1.978625197503207323e-20 0.000000000000000000e+00 7.075998291516123706e-21 3.780442842345970547e-19 5.039000268571800007e+03 3.850918684691038093e-19 3.748589860420716160e-19 5.373547012359562030e-20 1.863732119172769755e-31 1.788814532185378837e-21 3.370483433585679386e-27 2.791621027370974174e-25 9.824340759089780153e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.175841626939325311e-20 0.000000000000000000e+00 7.052387932543815232e-21 3.793864653018333137e-19 5.044700268268340551e+03 3.858159056639729677e-19 3.752811592532963506e-19 5.443521070984649783e-20 1.853981176295668767e-31 1.788036806806797301e-21 3.359430253786493784e-27 2.785456511666509881e-25 9.818465624173357471e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.052517073111602024e-20 0.000000000000000000e+00 7.028777573568663001e-21 3.798341586819381635e-19 5.050400267965566854e+03 3.841052884285021805e-19 3.757033345518095330e-19 5.448272795218501099e-20 1.844230233417394629e-31 1.787286806846635980e-21 3.348377084608515226e-27 2.779291995961304015e-25 9.812615635531797713e-22 0.000000000000000000e+00 0.000000000000000000e+00 1.963098677793321294e-20 0.000000000000000000e+00 7.005167214590670023e-21 3.802104266278132858e-19 5.056100267663476188e+03 3.831077246882433844e-19 3.761255119305826263e-19 5.383189838356486954e-20 1.834559293501605634e-31 1.786536806886384380e-21 3.337323926157293548e-27 2.773127480255359333e-25 9.806765646902717003e-22 0.000000000000000000e+00 0.000000000000000000e+00 1.987762638788469959e-20 0.000000000000000000e+00 6.981556855609846832e-21 3.805473552869991280e-19 5.061850276825659421e+03 3.840954567668468307e-19 3.765513954214307868e-19 5.215937131599467519e-20 1.824820670388946102e-31 1.785750623752722715e-21 3.326173802796366231e-27 2.766908879611818010e-25 9.800785162268759739e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.020486023062118587e-20 0.000000000000000000e+00 6.957739349003319739e-21 3.807523465232472414e-19 5.067600267056061966e+03 3.870879887793750156e-19 3.769772796126571902e-19 5.060071399770196414e-20 1.815099559357497524e-31 1.784950956237236534e-21 3.315023727284173945e-27 2.760690299442884384e-25 9.794768627603320326e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.026100935317891808e-20 0.000000000000000000e+00 6.934162016776390696e-21 3.809659277796878031e-19 5.073300266756016754e+03 3.867647405751712475e-19 3.773994632264200927e-19 5.254820959861869009e-20 1.805694559852572016e-31 1.784160749443658014e-21 3.303970601855554582e-27 2.754525783734727385e-25 9.788808507828887418e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.060559387273158530e-20 0.000000000000000000e+00 6.911752919260433891e-21 3.816650015920388873e-19 5.079050275888200304e+03 3.894568949862787665e-19 3.778253529833863387e-19 5.177325817945653775e-20 1.796207044784469172e-31 1.783409114262980429e-21 3.292820512204981305e-27 2.748307183123630624e-25 9.782870601183438875e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.065862870268312880e-20 0.000000000000000000e+00 6.889147213621226057e-21 3.819827803742726232e-19 5.084800266152709810e+03 3.960404548285645945e-19 3.782512434242614301e-19 5.369116850900641887e-20 1.786739186753674877e-31 1.782657481548665281e-21 3.281670470620590860e-27 2.742088602917810812e-25 9.776932714035920771e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.042350175732989531e-20 0.000000000000000000e+00 6.866541582158785724e-21 3.826553897400352230e-19 5.090550275264945412e+03 3.938393903955301958e-19 3.786771373355278033e-19 5.264994401267801107e-20 1.777322190698164850e-31 1.781889106706816656e-21 3.270520404084310286e-27 2.735870002328287587e-25 9.770979519219795759e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.041921632845950780e-20 0.000000000000000000e+00 6.843935876598002359e-21 3.829312009332627923e-19 5.096350274951673782e+03 3.868317166856116339e-19 3.791067360625166019e-19 5.231323704775376317e-20 1.767823323286693153e-31 1.781087790960624044e-21 3.259273410747853077e-27 2.729597337230353122e-25 9.764950583673832260e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.048852004169079467e-20 0.000000000000000000e+00 6.821133637051666172e-21 3.833132207899631129e-19 5.102100265250250231e+03 3.916549940441986933e-19 3.795326327259709545e-19 5.343967485754337198e-20 1.758549391900223725e-31 1.780293384406215402e-21 3.248123404348940114e-27 2.723378756987690286e-25 9.758973631485710014e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.168564457429003619e-20 0.000000000000000000e+00 6.798528005455293963e-21 3.839549806119231075e-19 5.107850274332637127e+03 3.926025435410198984e-19 3.799585328341629131e-19 5.502904094037419991e-20 1.749406520315806801e-31 1.779531336688544246e-21 3.236973373485230340e-27 2.717160156430448156e-25 9.752969349034797864e-22 0.000000000000000000e+00 0.000000000000000000e+00 1.947385028105407440e-20 0.000000000000000000e+00 6.775922300011858412e-21 3.844813960701545421e-19 5.113650274021484620e+03 3.977759948883698645e-19 3.803881377932218594e-19 5.275970853534333763e-20 1.740184160562111271e-31 1.778773166794577033e-21 3.225726416441855932e-27 2.710887491330221937e-25 9.746904001492129526e-22 0.000000000000000000e+00 0.000000000000000000e+00 1.983394503151982871e-20 0.000000000000000000e+00 6.753120060457190320e-21 3.846060663588425263e-19 5.119450273711036971e+03 4.090682061102638272e-19 3.808177448275693617e-19 5.285505240928987687e-20 1.731004567536561286e-31 1.778015548868696430e-21 3.214479471820770624e-27 2.704614826229233941e-25 9.740843069700140238e-22 0.000000000000000000e+00 0.000000000000000000e+00 1.955223725357305210e-20 0.000000000000000000e+00 6.730317820899751448e-21 3.850292309421936521e-19 5.125250273401290542e+03 4.194667590931985168e-19 3.812473539301898350e-19 5.684708373657618432e-20 1.721840568025960556e-31 1.777262302155676543e-21 3.203232539752844661e-27 2.698342161127486926e-25 9.734817107558361372e-22 0.000000000000000000e+00 0.000000000000000000e+00 1.936637275803918546e-20 0.000000000000000000e+00 6.707525773223702344e-21 3.860120327553678076e-19 5.131050273092245334e+03 4.318620667845265724e-19 3.816769650940992315e-19 5.357468422096350143e-20 1.712676568514251925e-31 1.776509055442565625e-21 3.191985620370783924e-27 2.692069496024981808e-25 9.728791145430178745e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.024841569962086235e-20 0.000000000000000000e+00 6.685656703871931265e-21 3.860134081803284897e-19 5.136850272783897708e+03 4.025158197930095927e-19 3.821065783123449439e-19 5.386035382372186147e-20 1.703762297107198604e-31 1.775738599165832034e-21 3.180738713809181581e-27 2.685796830921722262e-25 9.722747973785210781e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.022829219779320731e-20 0.000000000000000000e+00 6.663787634517530089e-21 3.864764719105010203e-19 5.142650272476245846e+03 4.759059999070829942e-19 3.825361935780054690e-19 5.779181803677935078e-20 1.694854643258703413e-31 1.774947690116875611e-21 3.169491820204532803e-27 2.679524165817710583e-25 9.716684349421263297e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.018026573212638145e-20 0.000000000000000000e+00 6.641918565160506337e-21 3.874652067157938011e-19 5.148500281635420833e+03 4.205315044214418032e-19 3.829695151918812097e-19 5.296878666969074073e-20 1.685891918705806010e-31 1.774149961595170161e-21 3.158147965525104584e-27 2.673197415773340770e-25 9.710568442548366727e-22 0.000000000000000000e+00 0.000000000000000000e+00 1.997212753526715188e-20 0.000000000000000000e+00 6.619860933638558430e-21 3.871926405862873198e-19 5.154350271857743792e+03 4.453082858056232935e-19 3.834028374718310106e-19 5.377907002101214872e-20 1.677023044640358717e-31 1.773387061695775033e-21 3.146804161034047293e-27 2.666870686209063987e-25 9.704484595382830470e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.012734079303481923e-20 0.000000000000000000e+00 6.597803373518568126e-21 3.877404437023369337e-19 5.160150271552176491e+03 4.161886374275657927e-19 3.838324588734023605e-19 5.156155868027441760e-20 1.668229958683861206e-31 1.772638674638428953e-21 3.135557307370793840e-27 2.660598021102797288e-25 9.698460091217582828e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.205325550352932019e-20 0.000000000000000000e+00 6.575934304153683421e-21 3.879685846274682379e-19 5.166000280681370896e+03 4.621741529109865455e-19 3.842657866528479583e-19 5.331255466416015231e-20 1.659420322144326256e-31 1.771883834750791006e-21 3.124213493474793435e-27 2.654271271090851833e-25 9.692372025381146785e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.037960176850497577e-20 0.000000000000000000e+00 6.553876672744778574e-21 3.885418687060438145e-19 5.171850270937859023e+03 4.435165602007552993e-19 3.846991150822335233e-19 5.436022224628886988e-20 1.650695892230946404e-31 1.771128997298340633e-21 3.112869730086280110e-27 2.647944541489625039e-25 9.686220112066280312e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.096175975555718720e-20 0.000000000000000000e+00 6.531819112495967631e-21 3.891459598496216198e-19 5.177700280047117303e+03 4.073040943212791296e-19 3.851324469490992606e-19 5.295456977396497103e-20 1.641971434201336567e-31 1.770374157413275232e-21 3.101525944204118455e-27 2.641617791499240263e-25 9.680068178940788736e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.094929968177234648e-20 0.000000000000000000e+00 6.509761481162231980e-21 3.893796470882515278e-19 5.183550270326314603e+03 4.153852255393031796e-19 3.855657794552566911e-19 5.053161260811622251e-20 1.633354942050347524e-31 1.769619319957894964e-21 3.090182209054181482e-27 2.635291061873453902e-25 9.673916265632379019e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.106250853891697242e-20 0.000000000000000000e+00 6.487703920827795396e-21 3.894922350021869246e-19 5.189400279415724981e+03 4.097405634928555112e-19 3.859991153820229549e-19 5.255046561211907775e-20 1.624798855136755894e-31 1.768864480075390447e-21 3.078838451805255995e-27 2.628964311904534295e-25 9.667764332558155924e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.097350934988638093e-20 0.000000000000000000e+00 6.467350407943676366e-21 3.901828376105150339e-19 5.195300279098408282e+03 4.466871214145045299e-19 3.864361563785023705e-19 5.139982163787640068e-20 1.616169653146868166e-31 1.768103189793754112e-21 3.067397772480186505e-27 2.622583497406893110e-25 9.661559828848717058e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.136030289777403252e-20 0.000000000000000000e+00 6.447195995914076823e-21 3.904826925017701997e-19 5.201200278781812813e+03 4.197069981801061444e-19 3.868731994231921041e-19 5.138585533673678194e-20 1.607653095349879474e-31 1.767346118104895902e-21 3.057460438591626688e-27 2.616847040851444039e-25 9.655357012587907857e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.163966572887330054e-20 0.000000000000000000e+00 6.427041583882013443e-21 3.909284030721782047e-19 5.207100278465933116e+03 4.020639913472894251e-19 3.873102445091584709e-19 5.235655122002462482e-20 1.599154200099379573e-31 1.766589707888983107e-21 3.047946721672428703e-27 2.611292151018342147e-25 9.649154460930598669e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.144669452869475642e-20 0.000000000000000000e+00 6.406887171847505035e-21 3.914786006513273356e-19 5.213000278150770100e+03 4.025714003188647121e-19 3.877472916294991787e-19 5.474741626060041263e-20 1.590673754216718823e-31 1.765826077444801396e-21 3.038433013732061077e-27 2.605737261184565723e-25 9.642960616016823473e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.099124590378914634e-20 0.000000000000000000e+00 6.386732759810548589e-21 3.922125858789592675e-19 5.218900277836318310e+03 3.988060282782396275e-19 3.881843407773426539e-19 5.473350032473041227e-20 1.582356193684409727e-31 1.765036905512339527e-21 3.028919314855150219e-27 2.600182371350119818e-25 9.636797571087403725e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.114468206074448456e-20 0.000000000000000000e+00 6.366578347771162161e-21 3.926506251311276812e-19 5.224800277522577744e+03 4.011440812039628787e-19 3.886213919458487157e-19 5.192382315942960186e-20 1.574038633151097827e-31 1.764247733579782489e-21 3.019405625127379723e-27 2.594627481515004432e-25 9.630634526172682358e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.103739439431443152e-20 0.000000000000000000e+00 6.346423935729346504e-21 3.926952492842778214e-19 5.230700277209544765e+03 4.095632341443213890e-19 3.890584451282073238e-19 5.339494724894459838e-20 1.565758151196486835e-31 1.763476887537237733e-21 3.009891944635521219e-27 2.589072591679222780e-25 9.624407071285457031e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.082799838863887114e-20 0.000000000000000000e+00 6.326269523685113655e-21 3.933133069998699556e-19 5.236600276897216645e+03 4.051716167351927002e-19 3.894955003176393974e-19 5.232997187165563907e-20 1.557555712606308486e-31 1.762720477320869786e-21 3.000378273467448003e-27 2.583517701842777157e-25 9.618128878829604379e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.061743965907433687e-20 0.000000000000000000e+00 6.306115111638472640e-21 3.935912205540825880e-19 5.242550286040818719e+03 4.039913425857337158e-19 3.899362620910305267e-19 5.214890949577141067e-20 1.549283748674959114e-31 1.761957655635792540e-21 2.990783972249804673e-27 2.577915727763420345e-25 9.611797471304390559e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.053515029581916877e-20 0.000000000000000000e+00 6.285789867179222147e-21 3.939987679782795796e-19 5.248500276269403912e+03 4.065297754122275754e-19 3.903770244906698441e-19 5.389521499514598342e-20 1.541103623603866489e-31 1.761203762497544081e-21 2.981189711198908060e-27 2.572313771492680347e-25 9.605540170588140188e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.070541230961769596e-20 0.000000000000000000e+00 6.266078488151179462e-21 3.946782459052840368e-19 5.254400275959189457e+03 4.055174845229987514e-19 3.908140856945686558e-19 5.101708491587668695e-20 1.533065320996207171e-31 1.760456927093773641e-21 2.971676068704088330e-27 2.566758881654244649e-25 9.599341448968470249e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.066146965808913805e-20 0.000000000000000000e+00 6.246874200508640569e-21 3.947256426665552990e-19 5.260350285072912811e+03 4.108489068456526900e-19 3.912548535105997005e-19 5.448476522784621230e-20 1.524958884337025272e-31 1.759703761383175718e-21 2.962081796733295820e-27 2.561156907603018886e-25 9.593080374010377313e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.053740451022299543e-20 0.000000000000000000e+00 6.227507133982603791e-21 3.956179137702926787e-19 5.266350284748126796e+03 4.108363440924554650e-19 3.916993265853445023e-19 5.304920574635061637e-20 1.516885800083117103e-31 1.758944267753401646e-21 2.952406926047572545e-27 2.555507867098124673e-25 9.586738614748365040e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.044224093868861422e-20 0.000000000000000000e+00 6.207977349969659674e-21 3.958573200228577567e-19 5.272300275022279493e+03 4.108103170163065708e-19 3.921400970297725978e-19 5.325975287975197857e-20 1.508909207061041055e-31 1.758191104427559393e-21 2.942812704537983461e-27 2.549905910784482345e-25 9.580449713436012496e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.084939053567792065e-20 0.000000000000000000e+00 6.188610344765750671e-21 3.963426069011910727e-19 5.278250284106151412e+03 4.091228447615823027e-19 3.925808708610500933e-19 5.391660604498035125e-20 1.500933843079617578e-31 1.757437938720740354e-21 2.933218462845233142e-27 2.544303936761361917e-25 9.574137689240798647e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.079734985083011134e-20 0.000000000000000000e+00 6.169243278336879315e-21 3.968643787569921846e-19 5.284250283783563646e+03 4.009379204539849661e-19 3.930253499834483431e-19 5.360201190250681264e-20 1.493039867600419986e-31 1.756678445090688302e-21 2.923543622940258487e-27 2.538654896254397732e-25 9.567757955420149658e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.150622786619318861e-20 0.000000000000000000e+00 6.149713494316779165e-21 3.972989297265349665e-19 5.290250283461707113e+03 4.096671339771662182e-19 3.934698311193158312e-19 5.565029046113450513e-20 1.485145892120260314e-31 1.755918951460543339e-21 2.913868793557793906e-27 2.533005855746745239e-25 9.561378221615632213e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.169749435026582049e-20 0.000000000000000000e+00 6.130183710294300190e-21 3.980299243698098568e-19 5.296250283140579995e+03 4.058538273402659059e-19 3.939143142618365950e-19 5.503139406213744790e-20 1.477294605876667509e-31 1.755164115328229170e-21 2.904193974803016870e-27 2.527356815238406276e-25 9.555000816571607562e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.120804037669526549e-20 0.000000000000000000e+00 6.110653926269446153e-21 3.983566943862786907e-19 5.302250282820179564e+03 4.069033862373206256e-19 3.943587994042256315e-19 5.802437144997638259e-20 1.469577241019314248e-31 1.754409398387398706e-21 2.894519166782511801e-27 2.521707774729383139e-25 9.548623471139442390e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.182541572934616139e-20 0.000000000000000000e+00 6.091124142242226833e-21 3.992532161790118702e-19 5.308250282500503090e+03 4.084183417881020425e-19 3.948032865397282230e-19 5.469076516735835248e-20 1.461859876161029781e-31 1.753654681446477589e-21 2.884844369604291948e-27 2.516058734219678123e-25 9.542246125723506563e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.188990811445911780e-20 0.000000000000000000e+00 6.071937085899245751e-21 3.992251710548982730e-19 5.314250282181548755e+03 4.079625361411014713e-19 3.952477756616202739e-19 5.359696243658210151e-20 1.454188623817435150e-31 1.752899964505465441e-21 2.875169583377823072e-27 2.510409693709293065e-25 9.535868780323837697e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.212981531999360327e-20 0.000000000000000000e+00 6.053149737363664004e-21 3.995294605933452016e-19 5.320250281863313830e+03 4.096192959171339878e-19 3.956922667632076851e-19 5.431174237896486323e-20 1.446571857754356105e-31 1.752145247564363015e-21 2.865494808214051419e-27 2.504760653198231179e-25 9.529491434940473408e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.245769576422764864e-20 0.000000000000000000e+00 6.034362388825829822e-21 4.000835851294380085e-19 5.326250281545795588e+03 4.120333016603877903e-19 3.961367598378262575e-19 5.405152261752583833e-20 1.438955091690367091e-31 1.751393714806775322e-21 2.855820044225424892e-27 2.499111612686494303e-25 9.523090367453181131e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.271666269212646464e-20 0.000000000000000000e+00 6.015575040285751480e-21 4.005023193085476690e-19 5.332300290681311708e+03 4.134253916672057752e-19 3.965849597128752815e-19 5.368599349857290024e-20 1.431353409016419637e-31 1.750637463664836044e-21 2.846064653388792655e-27 2.493415487934571915e-25 9.516624433170825541e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.298108283345743956e-20 0.000000000000000000e+00 5.996631100899976956e-21 4.009113072914601556e-19 5.338350280907638989e+03 4.103560024315456372e-19 3.970331601795634845e-19 5.563161335836736093e-20 1.423789109859191234e-31 1.749882154142217883e-21 2.836309304640109303e-27 2.487719380985780088e-25 9.510158519115274596e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.310980890319305694e-20 0.000000000000000000e+00 5.977687220723126146e-21 4.016266540181845992e-19 5.344350280592269883e+03 4.139381432312067825e-19 3.974776591660875847e-19 5.567872186026490018e-20 1.416287313846311234e-31 1.749169654179668006e-21 2.826634575060056712e-27 2.482070340472019617e-25 9.503746032361223243e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.269598401552402295e-20 0.000000000000000000e+00 5.958899872176317581e-21 4.020487390711379616e-19 5.350400289697959124e+03 4.095138169395270921e-19 3.979258649798651888e-19 5.305896095752099123e-20 1.408855597156073669e-31 1.748451215598367222e-21 2.816879219328169587e-27 2.476374215748179605e-25 9.497280098163659351e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.193859487420999484e-20 0.000000000000000000e+00 5.939955932883937871e-21 4.020955004030911125e-19 5.356500289368049380e+03 4.176993646145594839e-19 3.983777762662343445e-19 5.599868078000155165e-20 1.401375835655843940e-31 1.747714249767944320e-21 2.807043268268413758e-27 2.470631024567931230e-25 9.490761718940514024e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.209993264713327985e-20 0.000000000000000000e+00 5.920855461890422017e-21 4.029492817651853509e-19 5.362550279639965083e+03 4.269987452125018742e-19 3.988259846391179883e-19 5.269397385915278102e-20 1.393979664432041674e-31 1.746962698181370871e-21 2.797287967054464808e-27 2.464934917576217330e-25 9.484298388360558229e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.217649348116015437e-20 0.000000000000000000e+00 5.901911581570822934e-21 4.029508676324651588e-19 5.368600288715859278e+03 4.167084367591689352e-19 3.992741963641646967e-19 5.411295796419855599e-20 1.386719653540968904e-31 1.746211144258899434e-21 2.787532647735092187e-27 2.459238792880429847e-25 9.477835037709743570e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.179174684571403719e-20 0.000000000000000000e+00 5.883426311880805144e-21 4.035610716912999332e-19 5.374700288388181434e+03 4.140135081258079114e-19 3.997261135928758622e-19 5.262338142045094727e-20 1.379399653934182538e-31 1.745453380324449483e-21 2.777696733723238778e-27 2.453495601698080277e-25 9.471318281082085503e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.205385760754377815e-20 0.000000000000000000e+00 5.866049372846575306e-21 4.038253496216753283e-19 5.380800288061247556e+03 4.181452535606374445e-19 4.001780327998164665e-19 5.460716611031443146e-20 1.372121316585651263e-31 1.744695616389907374e-21 2.767860832392547970e-27 2.447752410515030001e-25 9.464801524471822872e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.228540350414153973e-20 0.000000000000000000e+00 5.848672433810226944e-21 4.045481262992619489e-19 5.386900287735054007e+03 5.080860603626327825e-19 4.006299539782922176e-19 5.724837364035616992e-20 1.364916819929486648e-31 1.743937852455272730e-21 2.758024943878712090e-27 2.442009219331283153e-25 9.458278553137162924e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.197659938000030635e-20 0.000000000000000000e+00 5.831295494771769087e-21 4.053426293226453392e-19 5.393000287409597149e+03 4.253950370833319044e-19 4.010818771216384352e-19 5.275914030002531909e-20 1.357712323272452134e-31 1.743180088520547056e-21 2.748189068319366360e-27 2.436266028146842489e-25 9.451686020322688597e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.204042890347955808e-20 0.000000000000000000e+00 5.813918555731213020e-21 4.051835549678731197e-19 5.399100287084877891e+03 4.197939771502767153e-19 4.015338022232213016e-19 5.083779861478932282e-20 1.350558954951846490e-31 1.742422324585729599e-21 2.738353205854116159e-27 2.430522836961707088e-25 9.445093487526149493e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.302211198413540100e-20 0.000000000000000000e+00 5.796541616688555734e-21 4.054397880873128036e-19 5.405200286760889867e+03 4.227575288248941531e-19 4.019857292764357437e-19 5.534751546798861439e-20 1.343441085507411214e-31 1.741668676471056503e-21 2.728517356624590117e-27 2.424779645775883381e-25 9.438536762310505790e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.244442991267852939e-20 0.000000000000000000e+00 5.779164677643815283e-21 4.064442759573114380e-19 5.411300286437633076e+03 4.227305633400363095e-19 4.024376582747073110e-19 5.539510808122208740e-20 1.336323216062122459e-31 1.740920210253051128e-21 2.718681520774456977e-27 2.419036454589371366e-25 9.432025119522269218e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.232804856702078733e-20 0.000000000000000000e+00 5.761787738596991668e-21 4.068910753284370304e-19 5.417400286115102972e+03 4.185161706368917204e-19 4.028895892114901525e-19 5.414162407860589475e-20 1.329333791139235111e-31 1.740171744034956604e-21 2.708845698449479042e-27 2.413293263402175177e-25 9.425513476751650015e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.239247488878094764e-20 0.000000000000000000e+00 5.744410799548097678e-21 4.071727819252547148e-19 5.423550295240194828e+03 4.209440599534169559e-19 4.033452271561026526e-19 4.848099413327345861e-20 1.322315545431777198e-31 1.739442866607631284e-21 2.698929253235377990e-27 2.407502987979889428e-25 9.418887825454754239e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.296782127588106096e-20 0.000000000000000000e+00 5.726891399651803179e-21 4.069422686045841895e-19 5.429700285466961759e+03 4.208731808102021745e-19 4.038008656576801778e-19 5.330460494911957484e-20 1.315304242214718387e-31 1.738721571457578532e-21 2.689012852546506529e-27 2.401712730350505603e-25 9.412244331128549188e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.367011795953548864e-20 0.000000000000000000e+00 5.709436300764169372e-21 4.080359067753211894e-19 5.435850294572138409e+03 4.228556274011733571e-19 4.042565075083959983e-19 5.673811136886914256e-20 1.308427740805889280e-31 1.737995669377651884e-21 2.679096435626743195e-27 2.395922454946970366e-25 9.405596018517576355e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.422807343283447216e-20 0.000000000000000000e+00 5.692685456983306182e-21 4.089814771306150552e-19 5.442000284821749119e+03 4.227336955375486237e-19 4.047121499060274378e-19 5.488011428479093926e-20 1.301551260480008952e-31 1.737241069347024932e-21 2.669180063477590310e-27 2.390132197296078668e-25 9.398917821991384716e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.524558689230993674e-20 0.000000000000000000e+00 5.675934664559544421e-21 4.092397934224828949e-19 5.448150293907098785e+03 4.273391187658107476e-19 4.051677956365016387e-19 5.392035376162832205e-20 1.294701781449722593e-31 1.736486467005263991e-21 2.660845639878775755e-27 2.385049575281156492e-25 9.392239605031251280e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.577490870820534368e-20 0.000000000000000000e+00 5.659183820832684758e-21 4.095956749992733498e-19 5.454350293573012095e+03 4.243509767891573956e-19 4.056271470548601663e-19 5.150613037228075889e-20 1.287870904624821901e-31 1.735728012978900983e-21 2.652537755844506290e-27 2.379967811670090445e-25 9.385527300752381946e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.668328930164096242e-20 0.000000000000000000e+00 5.642296817241470805e-21 4.097974999535005352e-19 5.460500283856782517e+03 4.255430034492550377e-19 4.060827952630699147e-19 5.375300047443543702e-20 1.281095125856036495e-31 1.734978014163806953e-21 2.644296892172500346e-27 2.374927037715811008e-25 9.378889824958296945e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.728577613064938285e-20 0.000000000000000000e+00 5.625546024724668571e-21 4.105760243856315541e-19 5.466650292912470832e+03 4.293829946765467394e-19 4.065384467798606184e-19 5.356483052724944323e-20 1.274381427431863401e-31 1.734228013059454789e-21 2.636056012114878372e-27 2.369886248375329435e-25 9.372252328923748993e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.538824557253681605e-20 0.000000000000000000e+00 5.608795181078597156e-21 4.108802834332938043e-19 5.472850292580640598e+03 4.309634553799051751e-19 4.069978040142512071e-19 5.608226235443353124e-20 1.267676776627912251e-31 1.733503319761998940e-21 2.627748154669445231e-27 2.364804484762413361e-25 9.365560879737610482e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.507873936668740068e-20 0.000000000000000000e+00 5.591908177481237530e-21 4.116509776492987131e-19 5.479050292249561608e+03 4.247458188634986076e-19 4.074571631846722316e-19 5.562140202953736817e-20 1.260972125823148786e-31 1.732785027117428811e-21 2.619440306303954048e-27 2.359722721148881990e-25 9.358869430570494290e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.438857067696907464e-20 0.000000000000000000e+00 5.575021173881831603e-21 4.120010216775716603e-19 5.485250291919230222e+03 4.296666053616632754e-19 4.079165242845827523e-19 5.266986075001042261e-20 1.254350271146306595e-31 1.732060570676457326e-21 2.611132467105087844e-27 2.354640957534737616e-25 9.352171562585842991e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.405959744065802050e-20 0.000000000000000000e+00 5.558134170280389909e-21 4.120481000627313886e-19 5.491450291589645531e+03 4.351626670411466645e-19 4.083758873074718743e-19 5.509552043268092280e-20 1.247760969171004667e-31 1.731309055564891666e-21 2.602824637160633820e-27 2.349559193919981160e-25 9.345445516339415854e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.389127413063038272e-20 0.000000000000000000e+00 5.541247166676913950e-21 4.128095819022132999e-19 5.497700300731812604e+03 4.390253924907830435e-19 4.088389575125084036e-19 5.226017201474421359e-20 1.241118517594329332e-31 1.730551478699174309e-21 2.594449805350073795e-27 2.344436440574990817e-25 9.338665217526686187e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.474752773622709373e-20 0.000000000000000000e+00 5.524763965476390730e-21 4.129494506837497877e-19 5.503950290927417882e+03 4.454225618762222180e-19 4.093020282546365277e-19 5.531653544931316715e-20 1.234595187957767829e-31 1.729814208923509672e-21 2.586075008515242924e-27 2.339313702759347976e-25 9.331864634537528172e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.423003304109062378e-20 0.000000000000000000e+00 5.508345241839036339e-21 4.137745387166515017e-19 5.510150290600066910e+03 4.594920969747099794e-19 4.097613970383369178e-19 5.377236742040434627e-20 1.228129985986982376e-31 1.729100269567265059e-21 2.577767207026470464e-27 2.334231939142760779e-25 9.325101012672733919e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.474961686900469236e-20 0.000000000000000000e+00 5.492057843300636791e-21 4.140560778423701347e-19 5.516400299712365268e+03 4.414959162019055125e-19 4.102244730286626589e-19 5.820713023311902452e-20 1.221627899717913435e-31 1.728380571548273143e-21 2.569392404222660225e-27 2.329109185822251942e-25 9.318282835190442174e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.546008835505351851e-20 0.000000000000000000e+00 5.475639069969131954e-21 4.151556847825827873e-19 5.522650289942321251e+03 4.403457202166970059e-19 4.106875495412213971e-19 5.591552169520794021e-20 1.215197273932178508e-31 1.727627237582748894e-21 2.561017636591698651e-27 2.323986447978453717e-25 9.311464678327936942e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.745566421763623881e-20 0.000000000000000000e+00 5.459220346241537966e-21 4.154254171674037516e-19 5.528900299034760792e+03 4.439533440495531825e-19 4.111506293661245503e-19 5.607134215913724381e-20 1.208766628738801416e-31 1.726869660723059472e-21 2.552642853653998716e-27 2.318863694674222263e-25 9.304646500909170793e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.524895315131512852e-20 0.000000000000000000e+00 5.442801572962201757e-21 4.157641362686676924e-19 5.535150289287546002e+03 4.445357948999547504e-19 4.116137097034578615e-19 5.224130427588189568e-20 1.202392122510471206e-31 1.726122557250220649e-21 2.544268106027478610e-27 2.313740956811712096e-25 9.297819853997860324e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.588449594782102996e-20 0.000000000000000000e+00 5.426382849174636116e-21 4.157623078674435511e-19 5.541400298360214038e+03 4.561744700663426109e-19 4.120767933370945171e-19 5.328630459185777058e-20 1.196099009926957083e-31 1.725407194765999873e-21 2.535893343349536095e-27 2.308618203523685933e-25 9.290967448844821520e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.723882362507322830e-20 0.000000000000000000e+00 5.409964075947239830e-21 4.164394017604746516e-19 5.547700298021394701e+03 4.442661623640421065e-19 4.125435828553599803e-19 5.460771459424079466e-20 1.189755561992250969e-31 1.724686110467430756e-21 2.527451605669809586e-27 2.303454475982871180e-25 9.284060234870291200e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.805355044440865464e-20 0.000000000000000000e+00 5.393413977448671445e-21 4.171260449015256336e-19 5.554000297683343888e+03 4.417104860991567035e-19 4.130103742930761743e-19 5.513527369736909018e-20 1.183499135310808689e-31 1.723944874528940992e-21 2.519009878526420490e-27 2.298290748441426894e-25 9.277177970513187435e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.935875325626374922e-20 0.000000000000000000e+00 5.376863878948084595e-21 4.177465109173501967e-19 5.560300297346058869e+03 4.426935292940577993e-19 4.134771676437421708e-19 5.477817224424331442e-20 1.177292735643082580e-31 1.723190383551369993e-21 2.510568162025667320e-27 2.293127020899354453e-25 9.270312117142745984e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.892155713602737560e-20 0.000000000000000000e+00 5.361347956025847837e-21 4.181304169851881571e-19 5.566550287655722059e+03 4.436295635359048557e-19 4.139402574758695670e-19 5.525204224279243459e-20 1.171135602332305654e-31 1.722441881717877547e-21 2.502193466434604041e-27 2.288004282990224914e-25 9.263500764889386949e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.981771457601160931e-20 0.000000000000000000e+00 5.346357941257303108e-21 4.187133022815414799e-19 5.572850306171878401e+03 4.929815585339833515e-19 4.144070560148245778e-19 5.391374519383581116e-20 1.165002559718746681e-31 1.721723019058289375e-21 2.493751746196492712e-27 2.282840539995130829e-25 9.256599260514843664e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.060062476135551140e-20 0.000000000000000000e+00 5.331247938534055529e-21 4.190567283943456655e-19 5.579200296338774933e+03 4.990269707824720812e-19 4.148775591088690444e-19 5.832142554330374253e-20 1.158833997842332823e-31 1.721000565087205253e-21 2.485243077463864780e-27 2.277635838269391161e-25 9.249640902843360621e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.073037974042523319e-20 0.000000000000000000e+00 5.316018083499764858e-21 4.201204725056329231e-19 5.585500296004528536e+03 5.209660541138798772e-19 4.153443600469093905e-19 5.630607542217593729e-20 1.152719715835652452e-31 1.720273774285175440e-21 2.476801404625690924e-27 2.272472110724828600e-25 9.242738408801396343e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.873188117159461602e-20 0.000000000000000000e+00 5.300908125987437596e-21 4.201651411039311428e-19 5.591800295671034291e+03 5.419940615700211957e-19 4.158111628658315056e-19 6.087470061183542951e-20 1.146671716155807127e-31 1.719523774324876821e-21 2.468359742983654496e-27 2.267308383179648906e-25 9.235838423873393760e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.727157995160442285e-20 0.000000000000000000e+00 5.285798168473306279e-21 4.211652179880551728e-19 5.598100295338292199e+03 5.414492734341946920e-19 4.162779675593079874e-19 5.611188331217970483e-20 1.140623716475239476e-31 1.718773774364489053e-21 2.459918092653030210e-27 2.262144655633853454e-25 9.228938438966559480e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.665884829308680850e-20 0.000000000000000000e+00 5.270688210957370155e-21 4.209253734179784989e-19 5.604450304445566871e+03 5.556949823966819446e-19 4.167484796420884645e-19 5.660133810772199941e-20 1.134569373327229413e-31 1.718041929854370558e-21 2.451409444010970732e-27 2.256939938383834684e-25 9.221959573051664513e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.718748254588363632e-20 0.000000000000000000e+00 5.255458310496362479e-21 4.214897245750129547e-19 5.610800294669797040e+03 6.595756007267020836e-19 4.172189922172527690e-19 5.833072736669000280e-20 1.128609041594031560e-31 1.717323776198058715e-21 2.442900832403841552e-27 2.251735236611102332e-25 9.214967039264254363e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.804461048092010136e-20 0.000000000000000000e+00 5.240228455324562667e-21 4.222462785512454947e-19 5.617150303757235633e+03 7.198416442703437971e-19 4.176895080752769935e-19 5.943630924627013250e-20 1.122648692155140345e-31 1.716605620408407815e-21 2.434392207376920462e-27 2.246530519377342118e-25 9.207974484727646117e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.720273493010713603e-20 0.000000000000000000e+00 5.224998554911129222e-21 4.228099857068293683e-19 5.623550303411538152e+03 8.243965934394861645e-19 4.181637299793367735e-19 5.777186392248065991e-20 1.116706500590969697e-31 1.715881810923694946e-21 2.425816610160990261e-27 2.241284827908537768e-25 9.200889081852181510e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.795140215575015239e-20 0.000000000000000000e+00 5.209980552059403900e-21 4.230965716301337222e-19 5.629900293670099018e+03 6.914576979147346392e-19 4.186342482081666040e-19 5.886337280528676523e-20 1.110865944579140733e-31 1.715163657263500398e-21 2.417308034546972560e-27 2.236080126107666561e-25 9.193858750615942552e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.798974632742733637e-20 0.000000000000000000e+00 5.195374693377165847e-21 4.237142141884288584e-19 5.636250302727869894e+03 6.536161813031207099e-19 4.191047696960763197e-19 5.530633840059319027e-20 1.105025371276286925e-31 1.714433691984867338e-21 2.408799445979591129e-27 2.230875408898223009e-25 9.186829825236485445e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.787202650002451385e-20 0.000000000000000000e+00 5.180768791454136761e-21 4.236921907908228387e-19 5.642650302384509814e+03 6.203411843564910817e-19 4.195789972575381706e-19 5.312694860367271663e-20 1.099204584731777701e-31 1.713676295575797570e-21 2.400223885857558582e-27 2.225629717427502970e-25 9.179748184090256421e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.973355089845871019e-20 0.000000000000000000e+00 5.166047904217305474e-21 4.240089139060890282e-19 5.649050302041928262e+03 5.771324062400574023e-19 4.200532267018879834e-19 5.508699910267770430e-20 1.093404811030930674e-31 1.712918899166635643e-21 2.391648338431596121e-27 2.220384025956144674e-25 9.172666542966756755e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.863171476700139814e-20 0.000000000000000000e+00 5.151327016978683674e-21 4.246520663586371822e-19 5.655450301700122509e+03 5.682938064275040091e-19 4.205274580227559375e-19 5.938560803652580732e-20 1.087605037329380589e-31 1.712191436868809902e-21 2.383072803838777909e-27 2.215138334484150417e-25 9.165587752727629084e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.957706309948600029e-20 0.000000000000000000e+00 5.136606129738277380e-21 4.257639633137423494e-19 5.661850301359088917e+03 5.214879479032441595e-19 4.210016912138006678e-19 5.801174116169908049e-20 1.081923215647550240e-31 1.711476142789278381e-21 2.374497282218161542e-27 2.209892643011523414e-25 9.158510121386752792e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.224498698851297508e-20 0.000000000000000000e+00 5.121885242496094866e-21 4.262364683430215885e-19 5.668250301018824757e+03 5.158314661542023259e-19 4.214759262687090723e-19 5.305324771608865171e-20 1.076242317073177987e-31 1.710760848709660719e-21 2.365921773710820332e-27 2.204646951538265500e-25 9.151430429479001453e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.352750395544015153e-20 0.000000000000000000e+00 5.107164355252142904e-21 4.261578866524045413e-19 5.674650300679329121e+03 5.202517862288315972e-19 4.219501631811971304e-19 5.654813018010459450e-20 1.070579624799417996e-31 1.710045554629957294e-21 2.357346278459875236e-27 2.199401260064377596e-25 9.144315151209036484e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.490303204015298530e-20 0.000000000000000000e+00 5.092443468006422247e-21 4.271856110666871241e-19 5.681050300340598369e+03 4.896453190932837560e-19 4.224244019450082180e-19 5.699288215594404040e-20 1.064985018353949055e-31 1.709330260550168105e-21 2.348770796610542569e-27 2.194155568589863373e-25 9.137199872962312448e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.628874391546167585e-20 0.000000000000000000e+00 5.077722580758943426e-21 4.278282095313623059e-19 5.687500309450541863e+03 4.759677563101046973e-19 4.229023482662068625e-19 5.703767604475023017e-20 1.059346695783683947e-31 1.708611076727717464e-21 2.340128319854858769e-27 2.188868887404029703e-25 9.130030695666051998e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.768443042570544446e-20 0.000000000000000000e+00 5.063053944076871924e-21 4.284264188817876165e-19 5.693950299660157725e+03 4.761339985416044528e-19 4.233802950545198818e-19 5.907519495326187272e-20 1.053754156269272735e-31 1.707894411148871468e-21 2.331485882339594975e-27 2.183582221709648536e-25 9.122864055532750570e-22 0.000000000000000000e+00 0.000000000000000000e+00 4.083353973361525727e-20 0.000000000000000000e+00 5.048712459289280507e-21 4.294617206850274731e-19 5.700400308750255135e+03 4.723341086236283466e-19 4.238582451032020519e-19 5.507531839266691068e-20 1.048219399865703046e-31 1.707177743472193866e-21 2.322999092926468534e-27 2.178368661429980384e-25 9.115697394445797782e-22 0.000000000000000000e+00 0.000000000000000000e+00 4.444733358476500516e-20 0.000000000000000000e+00 5.034370932521139344e-21 4.297601172826376399e-19 5.706850298982793902e+03 4.943239904251261075e-19 4.243361956095496955e-19 5.653422357046497095e-20 1.042684659643814797e-31 1.706461077890800903e-21 2.315813413085067069e-27 2.173766295129440592e-25 9.108530754336316572e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.536359906069986569e-20 0.000000000000000000e+00 5.020029447682579243e-21 4.295775271543723184e-19 5.713300308053130721e+03 4.669959353022762343e-19 4.248141493605638054e-19 6.010411437028555707e-20 1.037197951391873652e-31 1.705744410216318937e-21 2.308627720724919100e-27 2.169163915387260192e-25 9.101364093320726636e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.254277371514438226e-20 0.000000000000000000e+00 5.005687920958374862e-21 4.303108097714215168e-19 5.719800307703058934e+03 4.752525180260524162e-19 4.252958093401379923e-19 5.549635338563834517e-20 1.031692923755397943e-31 1.705018092666308714e-21 2.301386344543303774e-27 2.164525865054806060e-25 9.094133696648342944e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.140047549420189000e-20 0.000000000000000000e+00 4.991235240710919750e-21 4.300825584597646314e-19 5.726250297969868370e+03 4.685851935022924670e-19 4.257737653908511228e-19 5.569965331528478528e-20 1.026230250434457649e-31 1.704263707839781364e-21 2.294200690372883387e-27 2.159923498729812312e-25 9.086891618258950026e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.984538373365186653e-20 0.000000000000000000e+00 4.976893755796159780e-21 4.304706695084314250e-19 5.732700307010650249e+03 4.658401629379665585e-19 4.262517246628542152e-19 5.635073661687564170e-20 1.020885079537862131e-31 1.703509320817467807e-21 2.287015023996470528e-27 2.155321119008721015e-25 9.079649518815494081e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.119692950707678922e-20 0.000000000000000000e+00 4.962552229137670235e-21 4.311235785421913176e-19 5.739200306662941330e+03 4.610636733114920081e-19 4.267333901897937656e-19 5.908977100708797877e-20 1.015511746491968192e-31 1.702770486551468860e-21 2.279773674211634806e-27 2.150683068674580784e-25 9.072372892115823977e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.128945572992423888e-20 0.000000000000000000e+00 4.948099548884961698e-21 4.319724801146948757e-19 5.745700306316020033e+03 4.591574706367707258e-19 4.272150575628664458e-19 5.738411836465010252e-20 1.010149143150728103e-31 1.702056613757199906e-21 2.272532333439720141e-27 2.146045018339878519e-25 9.065121463458738524e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.163278310980915387e-20 0.000000000000000000e+00 4.933646868630501768e-21 4.322433747886276095e-19 5.752200305969881811e+03 4.979706978738575838e-19 4.276967267758350353e-19 5.715254081658894909e-20 1.004862955586924680e-31 1.701342740962845563e-21 2.265291001767173510e-27 2.141406968004617894e-25 9.057870034826460704e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.221115187017781973e-20 0.000000000000000000e+00 4.919378415411251399e-21 4.327312984088585880e-19 5.758750315100201078e+03 4.604976642317794893e-19 4.281821036938547343e-19 5.647508299483349576e-20 9.995360973328750288e-32 1.700620023331954688e-21 2.257993966277400814e-27 2.136733233595295029e-25 9.050528761501001051e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.433646352274656445e-20 0.000000000000000000e+00 4.906041804555476515e-21 4.332852664534339821e-19 5.765300305274652601e+03 4.605555942448794872e-19 4.286674810628026668e-19 5.619899087300214740e-20 9.942397557802779549e-32 1.699896477905707043e-21 2.250696961325822333e-27 2.132059512711860819e-25 9.043179079562605585e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.281316043564181894e-20 0.000000000000000000e+00 4.892705232296141191e-21 4.336109839442458869e-19 5.771800304930863604e+03 4.613230570357377058e-19 4.291491557862877059e-19 5.753268153442277527e-20 9.890397560553093096e-32 1.699179157261928048e-21 2.243455657626011252e-27 2.127421462374923738e-25 9.035879907935090123e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.477459607166751823e-20 0.000000000000000000e+00 4.879470446778624456e-21 4.344143100791274567e-19 5.778300304587846767e+03 4.603415468794454129e-19 4.296308323249042767e-19 5.613712260064336172e-20 9.838397563297228887e-32 1.698465284467230649e-21 2.236214363384024030e-27 2.122783412037435184e-25 9.028553335066562586e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.789832750533251986e-20 0.000000000000000000e+00 4.866235661259534628e-21 4.349686103932132437e-19 5.784850313678537532e+03 4.588085111499090124e-19 4.301162165968265048e-19 5.711221929171211636e-20 9.786656886383313902e-32 1.697745919306981478e-21 2.228917366027736131e-27 2.118109677656389387e-25 9.021170393335729185e-22 0.000000000000000000e+00 0.000000000000000000e+00 4.226322960043108048e-20 0.000000000000000000e+00 4.852899050484447934e-21 4.359761378032629844e-19 5.791400303898876700e+03 4.595660654362779446e-19 4.306016013010726758e-19 5.812048153121564033e-20 9.735408611252747629e-32 1.697028702447823659e-21 2.221620399487770194e-27 2.113435956740212149e-25 9.013789958003179648e-22 0.000000000000000000e+00 0.000000000000000000e+00 4.673571643229390932e-20 0.000000000000000000e+00 4.839562478131680181e-21 4.370435565964147597e-19 5.797950312969805964e+03 4.635402959362147169e-19 4.310869892267556128e-19 5.769339144659957398e-20 9.684160188631849431e-32 1.696313471572262613e-21 2.214323421838222141e-27 2.108762222373266774e-25 9.006411803401943410e-22 0.000000000000000000e+00 0.000000000000000000e+00 4.884223099241511057e-20 0.000000000000000000e+00 4.826225867396830376e-21 4.376951728264924118e-19 5.804550312613947426e+03 4.617489931485597623e-19 4.315760835392984163e-19 5.893545270888509965e-20 9.632982196920671721e-32 1.695592781955948281e-21 2.206970762751973318e-27 2.104052817420599493e-25 8.998977337733939577e-22 0.000000000000000000e+00 0.000000000000000000e+00 5.085293940081807612e-20 0.000000000000000000e+00 4.812787469808233855e-21 4.385706017152896432e-19 5.811100302868640028e+03 4.636472664238068362e-19 4.320614737150061147e-19 5.806183974839769484e-20 9.582309744840411521e-32 1.694877553135033622e-21 2.199673826218981679e-27 2.099379096479909524e-25 8.991599204382462665e-22 0.000000000000000000e+00 0.000000000000000000e+00 5.024208063245161597e-20 0.000000000000000000e+00 4.799450897385517982e-21 4.388613411972766157e-19 5.817650311910012533e+03 4.709932972168337976e-19 4.325468670889985418e-19 5.830675621365333458e-20 9.531659929338265609e-32 1.694162322262699637e-21 2.192376878946705146e-27 2.094705362134054630e-25 8.984221049896274410e-22 0.000000000000000000e+00 0.000000000000000000e+00 4.889615363980729949e-20 0.000000000000000000e+00 4.786114286710849727e-21 4.392196354077263746e-19 5.824250311556559609e+03 4.650265851136698306e-19 4.330359668752585218e-19 5.585445974635311226e-20 9.481600915625657276e-32 1.693442537602430704e-21 2.185024250740193564e-27 2.089995957179670484e-25 8.976779344674025170e-22 0.000000000000000000e+00 0.000000000000000000e+00 4.545604000761198584e-20 0.000000000000000000e+00 4.773173768276762141e-21 4.390131861521799605e-19 5.830850311203905221e+03 4.640624364129512542e-19 4.335250684829906764e-19 5.904357461991443017e-20 9.431541901906992706e-32 1.692725966212147466e-21 2.177671633088222913e-27 2.085286552224716959e-25 8.969311933376291999e-22 0.000000000000000000e+00 0.000000000000000000e+00 4.104288771139602876e-20 0.000000000000000000e+00 4.760251207402840826e-21 4.394780735567278661e-19 5.837450310852048460e+03 4.616694681871184171e-19 4.340141719060371817e-19 5.743570801530747561e-20 9.381699322392382593e-32 1.692009394821777711e-21 2.170319026098073196e-27 2.080577147269194512e-25 8.961844522105775755e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.951054480549722265e-20 0.000000000000000000e+00 4.747328646527357702e-21 4.396071522314168597e-19 5.844050310500985688e+03 4.633611613387401682e-19 4.345032771382676099e-19 5.661401419685576335e-20 9.332505882386096684e-32 1.691292823431321628e-21 2.162966429878486250e-27 2.075867742313104982e-25 8.954355680565463560e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.882768184651578920e-20 0.000000000000000000e+00 4.734406085650320293e-21 4.399226184253865959e-19 5.850700319619866605e+03 4.668478155389537032e-19 4.349960902387030993e-19 5.462423146958642688e-20 9.282939694199465728e-32 1.690570822441271542e-21 2.155558132625569805e-27 2.071122653287601924e-25 8.946793687370331170e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.642835533071602940e-20 0.000000000000000000e+00 4.721385608037805805e-21 4.399527022552345060e-19 5.857350309795946487e+03 4.689864560267958173e-19 4.354889037595696733e-19 5.603499899310342155e-20 9.233858606707870859e-32 1.689848823507868630e-21 2.148149867636914021e-27 2.066377577778663462e-25 8.939231715744873124e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.817202931734507765e-20 0.000000000000000000e+00 4.708365167514610949e-21 4.407646011448166921e-19 5.863950309447264772e+03 5.360741547631623745e-19 4.359780144099347473e-19 5.618841166917573370e-20 9.185649913602589306e-32 1.689136046139215610e-21 2.140797304565566805e-27 2.061668172820875205e-25 8.931731382825043318e-22 0.000000000000000000e+00 0.000000000000000000e+00 4.619074493843330701e-20 0.000000000000000000e+00 4.695442606632911435e-21 4.420330866494649279e-19 5.870600318536427039e+03 4.779001528240344294e-19 4.364708329487363913e-19 6.150858339405888948e-20 9.137075934168707407e-32 1.688418147430726544e-21 2.133389041093316670e-27 2.056923083816577651e-25 8.924174571564283241e-22 0.000000000000000000e+00 0.000000000000000000e+00 4.018567781983483700e-20 0.000000000000000000e+00 4.682422129078584857e-21 4.426404351047729840e-19 5.877250308746996780e+03 4.660731701245279015e-19 4.369636518942834617e-19 5.787948101849887132e-20 9.089100486399937248e-32 1.687711833008779990e-21 2.125980810165285553e-27 2.052178008283028884e-25 8.916629660987715540e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.947559004763017708e-20 0.000000000000000000e+00 4.669401688487860578e-21 4.425731988672775969e-19 5.883900317816405732e+03 4.696767193379675816e-19 4.374564740371268255e-19 5.882349354375675952e-20 9.041364205080071765e-32 1.687035560900026605e-21 2.118572569861945129e-27 2.047432919292826243e-25 8.909115543656298253e-22 0.000000000000000000e+00 0.000000000000000000e+00 4.477885714236510363e-20 0.000000000000000000e+00 4.656381210972209833e-21 4.436877706395224412e-19 5.890550308049891100e+03 4.699331768948917738e-19 4.379492965776890710e-19 5.495308817843142765e-20 8.993628058971593632e-32 1.686359290706790730e-21 2.111164362298472073e-27 2.042687843742926166e-25 8.901601447637413572e-22 0.000000000000000000e+00 0.000000000000000000e+00 4.494651590245426800e-20 0.000000000000000000e+00 4.643682685018778702e-21 4.436945092590962598e-19 5.897200317099632230e+03 4.744881530494325266e-19 4.384421223002781632e-19 6.004811502998564620e-20 8.946562082344222033e-32 1.685657352131289778e-21 2.103756145653863916e-27 2.037942754766757595e-25 8.894014411458296825e-22 0.000000000000000000e+00 0.000000000000000000e+00 4.327112177815998051e-20 0.000000000000000000e+00 4.631071171551895978e-21 4.446737455726800810e-19 5.903900316739774098e+03 4.788163525257605342e-19 4.389386545787321932e-19 5.695421440650053498e-20 8.899191274077704805e-32 1.684934056715592658e-21 2.096292250833000295e-27 2.033161995192602030e-25 8.886324656846677928e-22 0.000000000000000000e+00 0.000000000000000000e+00 4.681486802554338543e-20 0.000000000000000000e+00 4.618364852649511132e-21 4.451151703263846031e-19 5.910600316380731783e+03 4.797657612973057242e-19 4.394351886595613097e-19 5.950967651642554994e-20 8.851980604847405851e-32 1.684210761299807329e-21 2.088828368329550712e-27 2.028381235617864227e-25 8.878634902264786814e-22 0.000000000000000000e+00 0.000000000000000000e+00 5.271849211384555796e-20 0.000000000000000000e+00 4.605658533745578772e-21 4.465968685516590230e-19 5.917300316022501647e+03 4.789561311708030481e-19 4.399317245366625298e-19 5.698749823484144124e-20 8.805584908403323162e-32 1.683495471885238493e-21 2.081364498276041324e-27 2.023600476042546942e-25 8.870993183609471106e-22 0.000000000000000000e+00 0.000000000000000000e+00 5.514052940092460454e-20 0.000000000000000000e+00 4.592952214840105668e-21 4.470488692567910402e-19 5.924000315665083690e+03 4.784973435265275044e-19 4.404282622039607961e-19 5.803951646684290476e-20 8.759189211953615573e-32 1.682780303384064131e-21 2.073900640806902076e-27 2.018819716466650175e-25 8.863352190462875918e-22 0.000000000000000000e+00 0.000000000000000000e+00 5.503528046230508619e-20 0.000000000000000000e+00 4.580245895933093325e-21 4.476596002627982403e-19 5.930700315308471545e+03 4.778972567868777166e-19 4.409248016554079185e-19 6.132185048747517705e-20 8.713073119294937525e-32 1.682065134882803628e-21 2.066436796058511552e-27 2.014038956890178289e-25 8.855698836052594512e-22 0.000000000000000000e+00 0.000000000000000000e+00 5.698070433085490102e-20 0.000000000000000000e+00 4.567539577024551522e-21 4.488277249937600799e-19 5.937400314952664303e+03 4.008723021215946080e-18 4.414213428849832472e-19 5.666248883896758517e-20 8.667397852903343383e-32 1.681349966381457173e-21 2.058972964169221001e-27 2.009258197313132201e-25 8.848020202605354019e-22 0.000000000000000000e+00 0.000000000000000000e+00 5.622951171885989335e-20 0.000000000000000000e+00 4.554833258114484022e-21 4.486084639218520582e-19 5.944100314597660144e+03 4.939327821446895596e-19 4.419178858866929032e-19 5.965348799326446205e-20 8.621722586506273230e-32 1.680634797880025142e-21 2.051509145279393805e-27 2.004477437735513059e-25 8.840341569188168566e-22 0.000000000000000000e+00 0.000000000000000000e+00 5.495914362510073361e-20 0.000000000000000000e+00 4.542126939202893834e-21 4.493269421381469166e-19 5.950850323693244718e+03 2.259169111010325431e-18 4.424181369196956568e-19 5.983353096711135685e-20 8.576212806075173322e-32 1.679914291291170562e-21 2.043989629008310945e-27 1.999660994102290612e-25 8.832580058177273203e-22 0.000000000000000000e+00 0.000000000000000000e+00 4.371326685743923035e-20 0.000000000000000000e+00 4.529325779088102416e-21 4.486076526895418184e-19 5.957600313884777279e+03 6.750307653312795038e-19 4.429183883381875407e-19 5.835630886741417968e-20 8.531020358375714408e-32 1.679193786720164318e-21 2.036470147283773374e-27 1.994844563957983619e-25 8.824806211215371317e-22 0.000000000000000000e+00 0.000000000000000000e+00 4.218063908575586903e-20 0.000000000000000000e+00 4.517156424313524349e-21 4.487598099121967335e-19 5.964300313532176006e+03 5.799568824917440874e-19 4.434149366467455434e-19 6.084857119221014799e-20 8.486162606725749722e-32 1.678479856739781137e-21 2.029006368456833407e-27 1.990063804378649909e-25 8.817088988208988105e-22 0.000000000000000000e+00 0.000000000000000000e+00 4.059170461820661755e-20 0.000000000000000000e+00 4.505490839311357360e-21 4.494340166190549444e-19 5.971050322598193816e+03 5.276247442631678031e-19 4.439151930058088543e-19 5.969317648221258105e-20 8.441574345235428303e-32 1.677801084878393866e-21 2.021824851138453914e-27 1.985413684784784320e-25 8.809283130088261376e-22 0.000000000000000000e+00 0.000000000000000000e+00 4.140634360432362069e-20 0.000000000000000000e+00 4.493738181301054055e-21 4.498469116540148605e-19 5.977850322231228347e+03 5.018993319237849845e-19 4.444191560516221464e-19 5.979112207301709683e-20 8.396774347653084473e-32 1.677117286032614007e-21 2.015525851270106213e-27 1.981189622197553295e-25 8.801419461815232954e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.937019970519937276e-20 0.000000000000000000e+00 4.481898483105746460e-21 4.501744683514409446e-19 5.984600312468662196e+03 4.891388177870497723e-19 4.449194145592842960e-19 5.776876515895964655e-20 8.352381058402683906e-32 1.676425522572752275e-21 2.009273184533517540e-27 1.976996624732140792e-25 8.793630331412272108e-22 0.000000000000000000e+00 0.000000000000000000e+00 4.195095750026111929e-20 0.000000000000000000e+00 4.470145857878496279e-21 4.506372869624334812e-19 5.991350321505162356e+03 4.828992586764217969e-19 4.454196762167257138e-19 6.030809934122584257e-20 8.308952428834512345e-32 1.675713021618899548e-21 2.003020508680079443e-27 1.972803615589017055e-25 8.785867839301037574e-22 0.000000000000000000e+00 0.000000000000000000e+00 4.220653392231778686e-20 0.000000000000000000e+00 4.458393199919587467e-21 4.514871022650939932e-19 5.998150321140677079e+03 5.568363730773782779e-19 4.459236445844861620e-19 6.218921705266980057e-20 8.265202166629295458e-32 1.674995243879595047e-21 1.996721533948111851e-27 1.968579553000245260e-25 8.778047858169016297e-22 0.000000000000000000e+00 0.000000000000000000e+00 4.301296260758348150e-20 0.000000000000000000e+00 4.446553501719960823e-21 4.523149991519273303e-19 6.004950320777016714e+03 4.938203305064214693e-19 4.464276147229418826e-19 6.161783492843856280e-20 8.221592640163233839e-32 1.674277466140203653e-21 1.990422567795689664e-27 1.964355490410961023e-25 8.770200375351905312e-22 0.000000000000000000e+00 0.000000000000000000e+00 4.516593738875646448e-20 0.000000000000000000e+00 4.434713803518898760e-21 4.529432345497903433e-19 6.011750320414181260e+03 4.908010133214751486e-19 4.469315866261027519e-19 6.472661280724002071e-20 8.178333068003400753e-32 1.673559688400725367e-21 1.984123610304531048e-27 1.960131427821164573e-25 8.762342616597753568e-22 0.000000000000000000e+00 0.000000000000000000e+00 4.236847543840240524e-20 0.000000000000000000e+00 4.422874105316399773e-21 4.536029052425703265e-19 6.018550320052163443e+03 4.900265082387704237e-19 4.474355602880055130e-19 6.235698891271188553e-20 8.135073495838365346e-32 1.672844967994783643e-21 1.977824661557404180e-27 1.955907365230860044e-25 8.754478743223321651e-22 0.000000000000000000e+00 0.000000000000000000e+00 4.598462234896056038e-20 0.000000000000000000e+00 4.411034407112477403e-21 4.541195681898376559e-19 6.025350319690964170e+03 5.615979582240673951e-19 4.479395357027141610e-19 6.225191283141076900e-20 8.092233982881812236e-32 1.672164968030903663e-21 1.971525721638125450e-27 1.951683302640046976e-25 8.746545429162340701e-22 0.000000000000000000e+00 0.000000000000000000e+00 5.006766114043293382e-20 0.000000000000000000e+00 4.399371067209608250e-21 4.550327621291469131e-19 6.032150319330578895e+03 5.495403403042642719e-19 4.484435128643193651e-19 6.025626815012215168e-20 8.049778958676809646e-32 1.671484968066942246e-21 1.965226790631591395e-27 1.947459240048728353e-25 8.738612115134634705e-22 0.000000000000000000e+00 0.000000000000000000e+00 4.950384778399436893e-20 0.000000000000000000e+00 4.387958277482842888e-21 4.551986870589473653e-19 6.039000328420811456e+03 5.064154054921553273e-19 4.489511982011609004e-19 5.727279912168475724e-20 8.007011706155780146e-32 1.670786778901124060e-21 1.958881544298421705e-27 1.943204112301415317e-25 8.730642437296989197e-22 0.000000000000000000e+00 0.000000000000000000e+00 5.171842868691340224e-20 0.000000000000000000e+00 4.376461554318650849e-21 4.555599356141217109e-19 6.045850318606969267e+03 6.260681418400727851e-18 4.494588838975962824e-19 5.884997859880904907e-20 7.964955949557449885e-32 1.670071670035536106e-21 1.952536324697662018e-27 1.938948996297043121e-25 8.722700984131630137e-22 0.000000000000000000e+00 0.000000000000000000e+00 5.121058499379923079e-20 0.000000000000000000e+00 4.364964862882141445e-21 4.562036115856162599e-19 6.052700327677446694e+03 6.868450047654608724e-18 4.499665727483448607e-19 6.234574367437146566e-20 7.923134841548219189e-32 1.669356559198508334e-21 1.946191096915709532e-27 1.934693868562001603e-25 8.714759509107543611e-22 0.000000000000000000e+00 0.000000000000000000e+00 4.778002781227565837e-20 0.000000000000000000e+00 4.353468139751105494e-21 4.567957293030221662e-19 6.059550317886633820e+03 8.300659191405841829e-19 4.504742619499561785e-19 5.975792592556332325e-20 7.881313848692128320e-32 1.668667924188069451e-21 1.939845896008051815e-27 1.930438752543324191e-25 8.706754226530460943e-22 0.000000000000000000e+00 0.000000000000000000e+00 5.162513265542440365e-20 0.000000000000000000e+00 4.341971448275945084e-21 4.573681448859340006e-19 6.066400326937439786e+03 5.349892737899744243e-19 4.509819542908871353e-19 5.919228243030235454e-20 7.840127877883868567e-32 1.667986707818376190e-21 1.933500687142754367e-27 1.926183624820502305e-25 8.698731030784021322e-22 0.000000000000000000e+00 0.000000000000000000e+00 4.278661329533424104e-20 0.000000000000000000e+00 4.330474725177924537e-21 4.568822994414167263e-19 6.073300326565999057e+03 5.454213222584334772e-19 4.514933534681332892e-19 5.845947331391136362e-20 7.798655628807503617e-32 1.667296140957628600e-21 1.927109181368134803e-27 1.921897443665239683e-25 8.690656621384419211e-22 0.000000000000000000e+00 0.000000000000000000e+00 4.232465935793245993e-20 0.000000000000000000e+00 4.318894100317779169e-21 4.572497381449650364e-19 6.080150316809609649e+03 5.011540379919566175e-19 4.520010478958853187e-19 5.855539706409719079e-20 7.757625354129636142e-32 1.666584939784794615e-21 1.920764009268678528e-27 1.917642327625178605e-25 8.682683701145100577e-22 0.000000000000000000e+00 0.000000000000000000e+00 4.203563284380518675e-20 0.000000000000000000e+00 4.307397408784843869e-21 4.577365632333621938e-19 6.087000325830998008e+03 4.981632386891583687e-19 4.525087454406378667e-19 5.976132197585214250e-20 7.717170850589707581e-32 1.665873736662355476e-21 1.914418829556621037e-27 1.913387199920630605e-25 8.674710759085076547e-22 0.000000000000000000e+00 0.000000000000000000e+00 4.191793153730889198e-20 0.000000000000000000e+00 4.295900685736196343e-21 4.583826738578153309e-19 6.093900325462066576e+03 5.189510994000672976e-19 4.530201498443499256e-19 5.994892438063981769e-20 7.676421114548631225e-32 1.665173594185070421e-21 1.908027353411025710e-27 1.909101018763809076e-25 8.666640391461565171e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.922995512575386702e-20 0.000000000000000000e+00 4.284397432106400565e-21 4.586741752590936661e-19 6.100800325093968240e+03 5.047403391530823605e-19 4.535315559868774347e-19 5.796480885341895426e-20 7.636002283830766425e-32 1.664491176639058227e-21 1.901635887389367588e-27 1.904814837606470283e-25 8.658527224752862691e-22 0.000000000000000000e+00 0.000000000000000000e+00 4.140995926956242723e-20 0.000000000000000000e+00 4.273160973538589311e-21 4.591158418139745667e-19 6.107700324726703002e+03 5.055452321931569812e-19 4.540429638623451522e-19 6.106206649590359762e-20 7.596039785957845128e-32 1.663808759092963465e-21 1.895244431594079839e-27 1.900528656448613767e-25 8.650414058080081438e-22 0.000000000000000000e+00 0.000000000000000000e+00 4.184365036555776622e-20 0.000000000000000000e+00 4.261924514969420125e-21 4.600610401135876551e-19 6.114650333829401461e+03 5.417007783235436030e-19 4.545580800399028880e-19 6.172872829518089509e-20 7.555787649904718798e-32 1.663095889441529283e-21 1.888806662571054209e-27 1.896211410122745475e-25 8.642285065193820097e-22 0.000000000000000000e+00 0.000000000000000000e+00 4.113807436245780277e-20 0.000000000000000000e+00 4.250606617361523744e-21 4.605946217925851632e-19 6.121600323989363460e+03 5.117231511656783667e-19 4.550731965596728563e-19 5.776675499258157370e-20 7.515910650560718895e-32 1.662378227414141765e-21 1.882368921683372147e-27 1.891894175563834382e-25 8.634164172580252112e-22 0.000000000000000000e+00 0.000000000000000000e+00 4.779985277853068452e-20 0.000000000000000000e+00 4.239288750601349598e-21 4.612319575804435652e-19 6.128500323624587509e+03 5.729952851044438088e-19 4.555846096237910370e-19 6.125294103940703891e-20 7.476523152642981453e-32 1.661672794428029556e-21 1.875977497349368124e-27 1.887607994404431586e-25 8.626087558784660907e-22 0.000000000000000000e+00 0.000000000000000000e+00 4.067325985109026593e-20 0.000000000000000000e+00 4.228052292028127684e-21 4.615029307117286710e-19 6.135450332697674639e+03 5.267057246021987224e-19 4.560997310075615023e-19 5.977054915322062205e-20 7.436850184184108014e-32 1.660992902236097056e-21 1.869539760370507191e-27 1.883290748096957485e-25 8.617891100754231770e-22 0.000000000000000000e+00 0.000000000000000000e+00 4.224818449234776566e-20 0.000000000000000000e+00 4.216734394468452526e-21 4.619585205308235903e-19 6.142400322892237455e+03 5.419937297142819254e-19 4.566148527206422991e-19 6.099253523662376895e-20 7.397863478115978180e-32 1.660313011890976772e-21 1.863102051798184351e-27 1.878973513516552753e-25 8.609694665026291443e-22 0.000000000000000000e+00 0.000000000000000000e+00 4.412718244380287678e-20 0.000000000000000000e+00 4.205416527651931387e-21 4.628019065929173524e-19 6.149350331945644939e+03 5.129069126757609998e-19 4.571299775542207179e-19 6.183638656528566919e-20 7.358972235744579609e-32 1.659612737462134455e-21 1.856664336790227244e-27 1.874656267221303334e-25 8.601498207095572439e-22 0.000000000000000000e+00 0.000000000000000000e+00 4.287246987119835818e-20 0.000000000000000000e+00 4.194098630124304155e-21 4.633040992593712883e-19 6.156300322163195233e+03 5.194496712828344154e-19 4.576451027086019616e-19 6.129346227919701657e-20 7.320139156571816684e-32 1.658895075428800440e-21 1.850226650377977872e-27 1.870339032626619100e-25 8.593301771417241734e-22 0.000000000000000000e+00 0.000000000000000000e+00 4.555742480044403078e-20 0.000000000000000000e+00 4.182780763270349257e-21 4.639961137142847773e-19 6.163250331197005835e+03 5.192483662158280103e-19 4.581602309687255078e-19 6.553710679229379051e-20 7.281824080862102491e-32 1.658177411452483161e-21 1.843788957801541306e-27 1.866021786343542936e-25 8.585105313586575168e-22 0.000000000000000000e+00 0.000000000000000000e+00 4.282204296364590694e-20 0.000000000000000000e+00 4.171499815046446250e-21 4.648231114897395294e-19 6.170250330821270836e+03 5.228058225657983944e-19 4.586790662090810993e-19 6.139220044606905785e-20 7.243233409358381531e-32 1.657491859703876332e-21 1.837304971173051087e-27 1.861673486620136447e-25 8.576822173511650751e-22 0.000000000000000000e+00 0.000000000000000000e+00 4.346227211064420348e-20 0.000000000000000000e+00 4.161010986841881425e-21 4.648281984363500807e-19 6.177250330446388034e+03 5.238993235337187201e-19 4.591979031735973549e-19 6.250156480570957107e-20 7.204854909125770405e-32 1.656810778659270317e-21 1.830820996214314040e-27 1.857325186896200298e-25 8.568535707984432584e-22 0.000000000000000000e+00 0.000000000000000000e+00 4.157332284681610472e-20 0.000000000000000000e+00 4.150522158636039919e-21 4.653151696527185718e-19 6.184250330072352881e+03 5.433787354922978172e-19 4.597167418564362995e-19 6.120007870972554321e-20 7.166896148267446347e-32 1.656130613218804532e-21 1.824337033049769773e-27 1.852976887171737701e-25 8.560241561612912405e-22 0.000000000000000000e+00 0.000000000000000000e+00 4.005148558041794872e-20 0.000000000000000000e+00 4.140033330428928503e-21 4.655208580679792449e-19 6.191250329699163558e+03 5.255344129829091671e-19 4.602355822517866321e-19 5.977206323354494713e-20 7.128937387404536321e-32 1.655453193900080897e-21 1.817853081805633260e-27 1.848628587446749806e-25 8.551924378426750869e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.670146148274982752e-20 0.000000000000000000e+00 4.129544502220549434e-21 4.655717055470818746e-19 6.198250329326817337e+03 5.326549467026733736e-19 4.607544243538634370e-19 6.249123366822335906e-20 7.091493641716537099e-32 1.654775774581275824e-21 1.811369142609925336e-27 1.844280287721237989e-25 8.543607195279830155e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.624908958465570251e-20 0.000000000000000000e+00 4.119055674010906474e-21 4.664056444529115703e-19 6.205250328955311488e+03 5.299668675443868616e-19 4.612732681569073168e-19 5.879440141482252568e-20 7.054447489836506792e-32 1.654076041665855232e-21 1.804885215592506414e-27 1.839931987995204317e-25 8.535290012172280038e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.739810097500980554e-20 0.000000000000000000e+00 4.108566845800004888e-21 4.665284260484952435e-19 6.212250328584643285e+03 5.364755863483997152e-19 4.617921136551848744e-19 5.840635924743445503e-20 7.017401337952042690e-32 1.653360987940278422e-21 1.798401300885109851e-27 1.835583688268650167e-25 8.526972829104217128e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.670344895443982605e-20 0.000000000000000000e+00 4.098078017587847686e-21 4.669375302312927594e-19 6.219300337658571152e+03 5.362249640436504245e-19 4.623146676005717011e-19 6.191987530363386533e-20 6.980429003016706216e-32 1.652640825723049102e-21 1.791871076328936214e-27 1.831204323389842064e-25 8.518596226401783395e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.567307300889509084e-20 0.000000000000000000e+00 4.087514255018386955e-21 4.678265230119778814e-19 6.226350327840539649e+03 5.353905499568522247e-19 4.628372218535461992e-19 6.254508134315084214e-20 6.943552131295639416e-32 1.651956419886399312e-21 1.785340882033196029e-27 1.826824970246449340e-25 8.510148137465636319e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.818879061291617476e-20 0.000000000000000000e+00 4.076950520756715497e-21 4.686241986641489386e-19 6.233400336894783322e+03 6.213764831667629565e-19 4.633597792074628119e-19 6.019638277273296194e-20 6.906686029375702874e-32 1.651274160945666022e-21 1.778810683158557377e-27 1.822445605379868904e-25 8.501695728511530918e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.862421919868504520e-20 0.000000000000000000e+00 4.066386758216749331e-21 4.688685367891258679e-19 6.240450327099800234e+03 5.972315598564947384e-19 4.638823368605950785e-19 5.755669325612199574e-20 6.870572814243880458e-32 1.650594117618104129e-21 1.772280514787862604e-27 1.818066252222158797e-25 8.493270768515902316e-22 0.000000000000000000e+00 0.000000000000000000e+00 4.512471072545589163e-20 0.000000000000000000e+00 4.056130689955541178e-21 4.696336156212773239e-19 6.247500336134445206e+03 5.710189273078232002e-19 4.644048976000392291e-19 6.029981713473819245e-20 6.834459502658248891e-32 1.649919116753084971e-21 1.765750342165183641e-27 1.813686887367752763e-25 8.484908278912718289e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.739283415116321180e-20 0.000000000000000000e+00 4.045925540388838878e-21 4.698148705506567026e-19 6.254600335752877982e+03 6.603382651948180178e-19 4.649311654441994478e-19 6.142371182993728146e-20 6.798272427797747732e-32 1.649239329555575507e-21 1.759652844450781903e-27 1.809522990906750887e-25 8.476486492159942588e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.675042352518297754e-20 0.000000000000000000e+00 4.035648027597922963e-21 4.704297817519454616e-19 6.261700335372174777e+03 7.681985460016230246e-19 4.654574349915356869e-19 6.339769528950480964e-20 6.762664307879651486e-32 1.648557186969523273e-21 1.754185548231694412e-27 1.805683451655418082e-25 8.467961722892156987e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.819181538864083726e-20 0.000000000000000000e+00 4.025370514805755945e-21 4.713259431985160513e-19 6.268800334992333774e+03 6.036109421786919124e-19 4.659837062362772825e-19 5.992187430747679500e-20 6.727056187957230921e-32 1.647873764546192450e-21 1.748718260121234610e-27 1.801843912403618752e-25 8.459380996482878643e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.695891987520328832e-20 0.000000000000000000e+00 4.015093002012340834e-21 4.712928594065684404e-19 6.275900334613353152e+03 5.805317951860301853e-19 4.665099791726801484e-19 6.094132705339330525e-20 6.691649103641460912e-32 1.647190444322537816e-21 1.743250980195702727e-27 1.798004373151354276e-25 8.450801553288303051e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.816438039142301096e-20 0.000000000000000000e+00 4.004815489217680639e-21 4.720396083861481858e-19 6.283000334235229275e+03 6.442069086271242519e-19 4.670362537950252358e-19 6.333946093849095296e-20 6.656473470997038030e-32 1.646514253882359043e-21 1.737783708532359321e-27 1.794164833898626489e-25 8.442311628302114077e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.680555378621674051e-20 0.000000000000000000e+00 3.994537976421779875e-21 4.727671504340183021e-19 6.290100333857958503e+03 5.778112133646340717e-19 4.675625300976196883e-19 6.116209778954467674e-20 6.621297838348389358e-32 1.645838063442099209e-21 1.732316445209441418e-27 1.790325294645437459e-25 8.433821703358494925e-22 0.000000000000000000e+00 0.000000000000000000e+00 4.166378167227073219e-20 0.000000000000000000e+00 3.984260463624644559e-21 4.734033025533624708e-19 6.297200333481539928e+03 5.602917500056040694e-19 4.680888080747961681e-19 6.178434864368759255e-20 6.586520202323460856e-32 1.645148643724077950e-21 1.726849190306175071e-27 1.786485755391787415e-25 8.425305319970037661e-22 0.000000000000000000e+00 0.000000000000000000e+00 4.163388554172166257e-20 0.000000000000000000e+00 3.973982950826275445e-21 4.740010836694278092e-19 6.304300333105967184e+03 5.633516053714366608e-19 4.686150877209127599e-19 6.714872804185036256e-20 6.551921219382089374e-32 1.644434887148077411e-21 1.721381943902794369e-27 1.782646216137680029e-25 8.416740263033912004e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.965649565231087019e-20 0.000000000000000000e+00 3.963705438026682312e-21 4.750797967782198979e-19 6.311450342169117903e+03 5.596746977503554957e-19 4.691450759424129697e-19 6.604404452767637439e-20 6.517078535622571933e-32 1.643716103168184018e-21 1.715876197166865831e-27 1.778779632769035856e-25 8.408114877451108131e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.643476976120240297e-20 0.000000000000000000e+00 3.953550980853169648e-21 4.751899092764003918e-19 6.318600332352094483e+03 5.656073105088405335e-19 4.696750644454940560e-19 6.384986465571115191e-20 6.482957210704593785e-32 1.643023777871229162e-21 1.710370473756427242e-27 1.774913059610416026e-25 8.399463057973171015e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.541336339111785331e-20 0.000000000000000000e+00 3.943493162535939233e-21 4.753362324296231620e-19 6.325750341395609212e+03 5.664890071339885875e-19 4.702050560219777105e-19 6.283907095638149253e-20 6.448895861090261879e-32 1.642342824628989663e-21 1.704864744695044576e-27 1.771046476252390561e-25 8.390799841867508604e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.376875737865875322e-20 0.000000000000000000e+00 3.933435317687782512e-21 4.756056620571230736e-19 6.332950341007473980e+03 5.720688435358171074e-19 4.707387548167165885e-19 6.217737064807679652e-20 6.414659702598010559e-32 1.641657336115081483e-21 1.699320530396097358e-27 1.767152858984552595e-25 8.382076557013796992e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.491305440477791729e-20 0.000000000000000000e+00 3.923307151616634393e-21 4.761288817588074852e-19 6.340100331225051377e+03 5.737217953346388256e-19 4.712687483431470152e-19 6.264934436128546268e-20 6.381029597856038724e-32 1.640979968620784672e-21 1.693814833899175186e-27 1.763286285807221283e-25 8.373421328135032387e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.403143258346208123e-20 0.000000000000000000e+00 3.913249333250732117e-21 4.766508359323187149e-19 6.347250340239203069e+03 5.765561898417783647e-19 4.717987449213128168e-19 5.971887710476534874e-20 6.347399404704050300e-32 1.640302599345759682e-21 1.688309132063344070e-27 1.759419702465074864e-25 8.364766076549011130e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.351718269060534441e-20 0.000000000000000000e+00 3.903191488443879822e-21 4.767624426452387313e-19 6.354450339853689911e+03 5.774399270147532603e-19 4.723324487380493214e-19 6.097255067446497255e-20 6.313861443470101309e-32 1.639621957500699457e-21 1.682764945424456931e-27 1.755526085195818958e-25 8.356038115415326510e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.279298670300698280e-20 0.000000000000000000e+00 3.893063322369043848e-21 4.773986977144910166e-19 6.361650339469048959e+03 5.809201665918657968e-19 4.728661542252261410e-19 6.249478016049218635e-20 6.280885445231756711e-32 1.638943423505534724e-21 1.677220768231768209e-27 1.751632467926091477e-25 8.347292588957480768e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.830309545591391219e-20 0.000000000000000000e+00 3.882935156292980846e-21 4.785327413819333226e-19 6.368850339085279302e+03 5.825943755166731131e-19 4.733998613771934638e-19 6.174991452407921332e-20 6.247909446989421697e-32 1.638264889510287800e-21 1.671676600579270459e-27 1.747738850655892650e-25 8.338547062546430045e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.322600530165911007e-20 0.000000000000000000e+00 3.872806990215692320e-21 4.785841890237457130e-19 6.376050338702374574e+03 5.869668649420051906e-19 4.739335701883269966e-19 6.191395540051446603e-20 6.215103462291220497e-32 1.637586355514959438e-21 1.666132442562212874e-27 1.743845233385226151e-25 8.329773000452435704e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.409105910948163756e-20 0.000000000000000000e+00 3.862678824137186547e-21 4.791939721699135994e-19 6.383250338320334777e+03 5.932889364345123476e-19 4.744672806530277721e-19 6.242990653631406809e-20 6.182415464025681335e-32 1.636907821519549638e-21 1.660588294277110615e-27 1.739951616114091979e-25 8.320989777901580417e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.526843179662312790e-20 0.000000000000000000e+00 3.852933422516118011e-21 4.798737051284624921e-19 6.390500347390649040e+03 5.980766612503828219e-19 4.750046998063919948e-19 6.072983910095220747e-20 6.149500422846454304e-32 1.636224967432126496e-21 1.655005647615017412e-27 1.736030954721049614e-25 8.312146465890639439e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.538442454588679613e-20 0.000000000000000000e+00 3.843531527603468881e-21 4.801955607670673068e-19 6.397750337553558893e+03 5.989770409642288079e-19 4.755421192234427973e-19 6.238296449777044981e-20 6.117193526876743697e-32 1.635545280854353770e-21 1.649423025580623199e-27 1.732110303552757643e-25 8.303310563672951562e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.663878469924322977e-20 0.000000000000000000e+00 3.834129657210158121e-21 4.810326464675530404e-19 6.405000346604206243e+03 6.056549344522011549e-19 4.760795417001781541e-19 5.809373039773476400e-20 6.085019357358447445e-32 1.634865592505855661e-21 1.643840399173575825e-27 1.728189642170350746e-25 8.294474638485521966e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.660396129848929473e-20 0.000000000000000000e+00 3.824727762323013269e-21 4.810243765453100704e-19 6.412250336790250003e+03 6.055627465327440476e-19 4.766169644325109925e-19 5.870260888938505881e-20 6.052866187186964413e-32 1.634185905925914006e-21 1.638257797567778950e-27 1.724268990989548256e-25 8.285603837089981717e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.863568911448233104e-20 0.000000000000000000e+00 3.815325891899701636e-21 4.817887061111003197e-19 6.419500345821316841e+03 6.108763867636810551e-19 4.771543902101681701e-19 6.494235869295363723e-20 6.021124854115626704e-32 1.633506217579251550e-21 1.632675191831655524e-27 1.720348329617730221e-25 8.276692391299521958e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.884351037033525024e-20 0.000000000000000000e+00 3.805923997037948967e-21 4.831360872298458387e-19 6.426800345428508990e+03 6.124773403359257038e-19 4.776955233291611687e-19 6.534331708614321897e-20 5.989164656830407599e-32 1.632821842616077476e-21 1.627054103267245601e-27 1.716400634331895227e-25 8.267719498973767651e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.872757168364930974e-20 0.000000000000000000e+00 3.796457273823735126e-21 4.837151534239358915e-19 6.434050335649129011e+03 6.182256221920566577e-19 4.782329510038279489e-19 6.453443369495731591e-20 5.957589646814633435e-32 1.632145046416143377e-21 1.621471533172087216e-27 1.712479983132394341e-25 8.258815141769304711e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.325678341558465808e-20 0.000000000000000000e+00 3.787055403355585437e-21 4.837304517680224649e-19 6.441300344650916486e+03 6.188211763648477507e-19 4.787703817024444237e-19 6.180665473019045138e-20 5.926436142787150218e-32 1.631468879773489634e-21 1.615888959321600690e-27 1.708559321776410123e-25 8.249912304748624319e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.223917580305558279e-20 0.000000000000000000e+00 3.777653508531802175e-21 4.838368716708114830e-19 6.448600344260760721e+03 6.234915790971339292e-19 4.793115197619591604e-19 6.109020400467962247e-20 5.895067827631977434e-32 1.630788050794333122e-21 1.610267903171627394e-27 1.704611626489140888e-25 8.240935641745850423e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.251703300892773677e-20 0.000000000000000000e+00 3.768186785314149496e-21 4.842999496893462301e-19 6.455900343871488985e+03 6.305846833043839593e-19 4.798526594647176739e-19 6.547361968393637139e-20 5.863996579536971138e-32 1.630107221815094232e-21 1.604646858103663503e-27 1.700663931201393420e-25 8.231895770100369874e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.488660125180745454e-20 0.000000000000000000e+00 3.758810797617903572e-21 4.855717332856776005e-19 6.463200343483094912e+03 6.340795761709998562e-19 4.803938008051661600e-19 6.232120139857152783e-20 5.833214315164879395e-32 1.629426392835773528e-21 1.599025824234590490e-27 1.696716235913171392e-25 8.222855898507111366e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.292413634243819457e-20 0.000000000000000000e+00 3.749647226248797426e-21 4.855548638290028493e-19 6.470550352558891973e+03 6.371907496048208965e-19 4.809386509438137217e-19 6.424582622331660358e-20 5.802221173446248341e-32 1.628744582840717648e-21 1.593366294278956004e-27 1.692741496496640006e-25 8.213783255949050822e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.155033476046168396e-20 0.000000000000000000e+00 3.740420878808645074e-21 4.862532817389704051e-19 6.477900342703645038e+03 6.384095408747570186e-19 4.814835013280311218e-19 6.210574126639735863e-20 5.771763294749696324e-32 1.628066122211971099e-21 1.587706790496634149e-27 1.688766767317642745e-25 8.204737138655488208e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.208918970886349234e-20 0.000000000000000000e+00 3.731194555132327144e-21 4.865495317383118444e-19 6.485200342317883951e+03 6.430347357367923545e-19 4.820246475706507844e-19 5.989917574531253397e-20 5.741704472808712724e-32 1.627392276093733619e-21 1.582085791101344373e-27 1.684819072027996808e-25 8.195752548055964797e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.134644782741172070e-20 0.000000000000000000e+00 3.722030983759915319e-21 4.867601519597363750e-19 6.492550351364247035e+03 6.541194050588102699e-19 4.825695026259945974e-19 6.463111849578909990e-20 5.711439729676628153e-32 1.626743525911380376e-21 1.576426296251633794e-27 1.680844332627382809e-25 8.186633386318078758e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.142243438611192994e-20 0.000000000000000000e+00 3.712804636356711482e-21 4.879087795356045886e-19 6.499900341543707327e+03 9.395339757350409320e-19 4.831143579149888609e-19 6.718550449730092473e-20 5.681449587429585173e-32 1.626099454606994812e-21 1.570766827903628818e-27 1.676869603429616439e-25 8.177502753230087919e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.266077739306423606e-20 0.000000000000000000e+00 3.703578312636825405e-21 4.888733277909351264e-19 6.507250350570508090e+03 6.641385040300512377e-19 4.836592162278767745e-19 6.387874837195094470e-20 5.651473080026163163e-32 1.625447659947337764e-21 1.565107357147383422e-27 1.672894864039581201e-25 8.168365683861318215e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.269231233444896346e-20 0.000000000000000000e+00 3.694351965258177926e-21 4.889708342632003434e-19 6.514650350172294566e+03 6.728125541797581977e-19 4.842077819944835289e-19 6.159881229171421603e-20 5.621398599310822393e-32 1.624764583061018993e-21 1.559409406255942698e-27 1.668893090736145449e-25 8.159144171070935788e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.301763757070762280e-20 0.000000000000000000e+00 3.685062865519799456e-21 4.892429248084788273e-19 6.522000340386375683e+03 7.627008069027795629e-19 4.847526421607718281e-19 6.902576676510340578e-20 5.591998638454498106e-32 1.624086122425873052e-21 1.553749974675514442e-27 1.664918361519656806e-25 8.149984977557647984e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.199227119797261758e-20 0.000000000000000000e+00 3.675836541756454319e-21 4.907035761316175636e-19 6.529350349383927096e+03 6.792852356673929579e-19 4.852975053297938741e-19 6.424969251211522107e-20 5.562598602464290972e-32 1.623409661791272112e-21 1.548090541138192836e-27 1.660943622145439084e-25 8.140831098637478254e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.174490727388279420e-20 0.000000000000000000e+00 3.666638172904155166e-21 4.905773876064901910e-19 6.536750348988402948e+03 6.843376062004793681e-19 4.858460759714147483e-19 6.813370360521653515e-20 5.533235524356166436e-32 1.622730069990861057e-21 1.542392628106210192e-27 1.656941848840548888e-25 8.131618879551938356e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.129467829449395118e-20 0.000000000000000000e+00 3.657598758100641477e-21 4.916143208930958968e-19 6.544150348593773742e+03 6.873788692727649682e-19 4.863946482343886055e-19 6.357939826621161790e-20 5.504210283185586849e-32 1.622050478190367622e-21 1.536694728032586986e-27 1.652940075535174488e-25 8.122406660522716862e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.251138114454565704e-20 0.000000000000000000e+00 3.648559343296035424e-21 4.916255550587625070e-19 6.551550348200035842e+03 7.834546023173926418e-19 4.869432221132358860e-19 6.704703920802125650e-20 5.475185042011510584e-32 1.621374079859895103e-21 1.531565489496862503e-27 1.649245029326286237e-25 8.113168184201753901e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.059862826853858053e-20 0.000000000000000000e+00 3.639519928490340018e-21 4.925056510079066767e-19 6.559000357269900633e+03 6.906065399913687951e-19 4.874955049007959543e-19 6.320168684876078674e-20 5.446237454432810692e-32 1.620693368371278021e-21 1.526795898179841388e-27 1.645737696993474543e-25 8.103865152935336996e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.084039633826136756e-20 0.000000000000000000e+00 3.630419424994135914e-21 4.925585385351051870e-19 6.566450347409931965e+03 7.006355315685192397e-19 4.880477879116972589e-19 6.821785015811261980e-20 5.417450113891717761e-32 1.620012658612290475e-21 1.522026326885776098e-27 1.642230373572493272e-25 8.094551737540329082e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.969159676175200208e-20 0.000000000000000000e+00 3.621318944621529943e-21 4.937026462290598841e-19 6.573850347018861612e+03 8.387171676983310468e-19 4.885963666271113199e-19 6.662820422319482740e-20 5.388855940645561551e-32 1.619336516516043070e-21 1.517288768015645370e-27 1.638746584808238447e-25 8.085273591235868397e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.891114822817681992e-20 0.000000000000000000e+00 3.612279529812576254e-21 4.939816859983439619e-19 6.581300356059330625e+03 7.048081795980500760e-19 4.891486542650898419e-19 6.380256164258587153e-20 5.360565642105445268e-32 1.618655805030111945e-21 1.512519200599254805e-27 1.635239252489265673e-25 8.075932742984934425e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.928730644637017316e-20 0.000000000000000000e+00 3.603179026352280212e-21 4.941772701298820543e-19 6.588750346234102835e+03 7.096158557146053753e-19 4.897009421147150648e-19 6.266138444581464652e-20 5.332356941443687707e-32 1.617998701086397249e-21 1.507749653390632365e-27 1.631731929051929189e-25 8.066544706943276138e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.916091379434204581e-20 0.000000000000000000e+00 3.594078545937236825e-21 4.945705275427150890e-19 6.596200355255036811e+03 7.183372013558403941e-19 4.902532329662268178e-19 6.878353275768442519e-20 5.304200604534189613e-32 1.617355806906925704e-21 1.502980102323722536e-27 1.628224596742153281e-25 8.057128224440543337e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.854265722597838551e-20 0.000000000000000000e+00 3.584978042500803506e-21 4.958933425390330484e-19 6.603700354851564043e+03 7.406281431424966509e-19 4.908092313800780307e-19 6.698658173538273750e-20 5.276364067570157455e-32 1.616708598819915773e-21 1.498178555288642682e-27 1.624693729754705087e-25 8.047648556119533812e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.020250422415876295e-20 0.000000000000000000e+00 3.575816473446369064e-21 4.962954189377017507e-19 6.611150345060987092e+03 7.480260553345005797e-19 4.913615240410208998e-19 6.632306531132742002e-20 5.248713142369798868e-32 1.616035144667850502e-21 1.493409032971890674e-27 1.621186406301055405e-25 8.038288533189321099e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.862632226272921469e-20 0.000000000000000000e+00 3.567366787215808063e-21 4.966591854005421440e-19 6.618600354052710827e+03 7.418800601399402012e-19 4.919138196829132258e-19 6.540670690123364544e-20 5.221194860192019466e-32 1.615361274507795064e-21 1.488639507076508477e-27 1.617679074005031403e-25 8.028929251796378986e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.802408874965924557e-20 0.000000000000000000e+00 3.558963258525793573e-21 4.970498094774250154e-19 6.626100353651962905e+03 7.506389070643169828e-19 4.924698229053655608e-19 6.844441162528155669e-20 5.193791015502444214e-32 1.614681786031639844e-21 1.483837985605505828e-27 1.614148207016300497e-25 8.019467692589841418e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.892080558163608091e-20 0.000000000000000000e+00 3.550503340977045530e-21 4.980596684540468985e-19 6.633600353252120840e+03 7.526604660621280078e-19 4.930258277269869584e-19 6.627648685493301656e-20 5.166387170809559489e-32 1.613999967886170879e-21 1.479036472860263789e-27 1.610617340027143014e-25 8.009922265590825991e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.887853937268400073e-20 0.000000000000000000e+00 3.542043423427276593e-21 4.983139594754447160e-19 6.641100352853182812e+03 7.645180519886987408e-19 4.935818341423732592e-19 6.411523378924441574e-20 5.139137185838493117e-32 1.613318149740619724e-21 1.474234968926047312e-27 1.607086473037560104e-25 8.000376838655178174e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.969768090183999087e-20 0.000000000000000000e+00 3.533583505876487516e-21 4.986295935043496924e-19 6.648650361915567373e+03 7.535371297299819224e-19 4.941415495730276959e-19 6.311955769870707942e-20 5.111840999228333328e-32 1.612662219237176709e-21 1.469401457894128152e-27 1.603532062479238261e-25 7.990781809961886765e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.989534775755234603e-20 0.000000000000000000e+00 3.525067178200091113e-21 4.990684789686357314e-19 6.656200352052714152e+03 7.762025180827727142e-19 4.947012652047720411e-19 6.429371195926390713e-20 5.084544881040185972e-32 1.612020470075519321e-21 1.464567968084418375e-27 1.599977660830582967e-25 7.981193349842764111e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.947429766063132301e-20 0.000000000000000000e+00 3.516550871871156613e-21 4.997472952901490940e-19 6.663700351656478233e+03 7.857395606879720848e-19 4.952572763902696577e-19 6.411358460281061247e-20 5.057973881247999233e-32 1.611381968350917079e-21 1.459766491227694360e-27 1.596446793839727905e-25 7.971667375829651589e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.883059959288377518e-20 0.000000000000000000e+00 3.508090954317319149e-21 5.002370075772478931e-19 6.671250360689517038e+03 7.883337447709313605e-19 4.958169966042388156e-19 7.045042482654408381e-20 5.031386289629260534e-32 1.610702467537943381e-21 1.454933007744243851e-27 1.592892383295221335e-25 7.962041141907415986e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.829305848553541584e-20 0.000000000000000000e+00 3.499574626674024667e-21 5.016111332141440337e-19 6.678800350861423794e+03 8.005604296561869776e-19 4.963767170078316654e-19 6.786572449180830533e-20 5.004798783680397805e-32 1.610022968422471734e-21 1.450099545716275289e-27 1.589337981630201644e-25 7.952414932099860184e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.760281179798775069e-20 0.000000000000000000e+00 3.491058320305880942e-21 5.017697968577209284e-19 6.686350359874960304e+03 8.190971416776875122e-19 4.969364403907863317e-19 6.886364867802494115e-20 4.978625419100137703e-32 1.609357719410628333e-21 1.445266081100806108e-27 1.585783571094876557e-25 7.942774446578072005e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.785668806218744992e-20 0.000000000000000000e+00 3.482733339364067728e-21 5.024732563109965235e-19 6.693950359466375630e+03 8.082491176827287137e-19 4.974998714410533658e-19 6.431570237853811101e-20 4.952278753849898636e-32 1.608711719445358120e-21 1.440400622521762876e-27 1.582205625880803101e-25 7.933046475191329687e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.741156034447751695e-20 0.000000000000000000e+00 3.474420009195018185e-21 5.024035371859095287e-19 6.701550359058716822e+03 8.230895160246409752e-19 4.980633040841137678e-19 6.512604256734722131e-20 4.926060392957150441e-32 1.608065719480009103e-21 1.435535173738081101e-27 1.578627680666293886e-25 7.923318503872377658e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.754330547375420147e-20 0.000000000000000000e+00 3.466106679024955271e-21 5.030728749721490264e-19 6.709150358651981151e+03 8.249399605171888686e-19 4.986267383145681930e-19 6.759118457372703045e-20 4.900270820877637160e-32 1.607393997732658487e-21 1.430669734849705605e-27 1.575049735451349830e-25 7.913570292589586421e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.722092827807346724e-20 0.000000000000000000e+00 3.457793348853883502e-21 5.039378311130296751e-19 6.716750358246166797e+03 8.351750073864792172e-19 4.991901741270419487e-19 6.668416681386523686e-20 4.874481248794996683e-32 1.606713400754074660e-21 1.425804305957944394e-27 1.571471790235972310e-25 7.903815097607283560e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.752068156382707859e-20 0.000000000000000000e+00 3.449480018681802876e-21 5.043908217897016575e-19 6.724350357841269215e+03 8.503014750071364811e-19 4.997536115161836460e-19 6.768472009181698046e-20 4.848822495963891750e-32 1.606036851072764558e-21 1.420938887165494663e-27 1.567893845020163164e-25 7.894057241465092239e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.767479754669501384e-20 0.000000000000000000e+00 3.441166688508720165e-21 5.050899247862639161e-19 6.731950357437286584e+03 8.621251641750304260e-19 5.003170504766670293e-19 6.449382572193651435e-20 4.823321075518487825e-32 1.605397247146367067e-21 1.416073478576463247e-27 1.564315899803923079e-25 7.884275092364091447e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.712512984788482357e-20 0.000000000000000000e+00 3.432853358334636121e-21 5.052003173233867347e-19 6.739550357034214358e+03 8.613768873883932971e-19 5.008804910031888579e-19 6.577157164629088438e-20 4.797819655070029508e-32 1.604757643219892840e-21 1.411208080296392808e-27 1.560737954587254582e-25 7.874492943332967681e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.647594761199198221e-20 0.000000000000000000e+00 3.424540028159556762e-21 5.058883913515758022e-19 6.747150356632049807e+03 8.673000053527465311e-19 5.014439330904704468e-19 6.454891342237563186e-20 4.772691282000440296e-32 1.604102924042478434e-21 1.406342692432286407e-27 1.557160009370158590e-25 7.864715533193456170e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.615761911415957317e-20 0.000000000000000000e+00 3.416226697983483593e-21 5.062723215657185514e-19 6.754800365665887512e+03 8.734428402279919561e-19 5.020110843041555738e-19 6.764710347282839670e-20 4.747576158002557472e-32 1.603424598118295787e-21 1.401445300024424623e-27 1.553558520596244142e-25 7.854879836261471371e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.591210699047317607e-20 0.000000000000000000e+00 3.407858664521173918e-21 5.072252932609917234e-19 6.762450355825172664e+03 8.861998466984303996e-19 5.025782356891654584e-19 6.461331185533738471e-20 4.722461095970187437e-32 1.602746273867718803e-21 1.396547930475849355e-27 1.549957040708134627e-25 7.845044163669334667e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.598588154409291470e-20 0.000000000000000000e+00 3.399610570550922456e-21 5.073950834328473387e-19 6.770100364839506256e+03 9.068053230604654037e-19 5.031453900373682071e-19 6.909687206536372140e-20 4.697841081923838500e-32 1.602097506392750731e-21 1.391650559746598205e-27 1.546355551943402122e-25 7.835119791828335935e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.618149840456727239e-20 0.000000000000000000e+00 3.391457421140521674e-21 5.085565993030527686e-19 6.777800364425025691e+03 9.037112168888594145e-19 5.037162521486909236e-19 6.907054681903047900e-20 4.673114322691466704e-32 1.601452678841253921e-21 1.386721197245874637e-27 1.542730528503072354e-25 7.825106028981076960e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.827015707897148900e-20 0.000000000000000000e+00 3.383250993283622193e-21 5.092294455927570779e-19 6.785450354619066275e+03 9.155635083225288388e-19 5.042834082265506516e-19 6.439950348525116604e-20 4.648566004033028082e-32 1.600806865107668969e-21 1.381823860765649392e-27 1.539129048598600738e-25 7.815157302860318544e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.775688708253246408e-20 0.000000000000000000e+00 3.375097863931323621e-21 5.091503326889968114e-19 6.793100363604235099e+03 9.339862454068685206e-19 5.048505672470505862e-19 6.594001283975586240e-20 4.624143440136714566e-32 1.600128539187801797e-21 1.376926523497590205e-27 1.535527559847598557e-25 7.805208552377367297e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.690410390711454268e-20 0.000000000000000000e+00 3.366944714552006295e-21 5.098632339077828696e-19 6.800800363192555778e+03 9.398579645499860581e-19 5.054214340476777981e-19 6.879724081724023701e-20 4.599561281826582962e-32 1.599445780603615800e-21 1.371997195016493571e-27 1.531902536405950032e-25 7.795194789754815822e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.646498487165985193e-20 0.000000000000000000e+00 3.358738286692121246e-21 5.107824671652883612e-19 6.808500362781807780e+03 9.511313492045910053e-19 5.059923024076139671e-19 6.712857500307023247e-20 4.575221304265792977e-32 1.598784847964435473e-21 1.367067878170484361e-27 1.528277512963863221e-25 7.785173630152668914e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.641371516373040255e-20 0.000000000000000000e+00 3.350531858831243515e-21 5.111228113599380220e-19 6.816200362371986557e+03 9.563478382851575690e-19 5.065631723215871491e-19 7.045136074723842442e-20 4.551329716752340877e-32 1.598146311413054720e-21 1.362138573085887502e-27 1.524652489521339962e-25 7.775144880343674878e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.567731360888096927e-20 0.000000000000000000e+00 3.342325430969377994e-21 5.120969595277226342e-19 6.823950371424653895e+03 9.751080839756283549e-19 5.071377514486198353e-19 6.396323973140251974e-20 4.527282959691727569e-32 1.597503627735516356e-21 1.357177265473946802e-27 1.521003922509528823e-25 7.765050996533557036e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.594352189666047010e-20 0.000000000000000000e+00 3.334065704527231167e-21 5.118274438537437418e-19 6.831700361549825175e+03 9.785078157039100066e-19 5.077123307359546040e-19 6.568006799004535268e-20 4.503404499174367404e-32 1.596858303204181177e-21 1.352215982156432103e-27 1.517355364408447458e-25 7.754883771568069957e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.581481550474930341e-20 0.000000000000000000e+00 3.325805998257440088e-21 5.126073537672682552e-19 6.839400361142781549e+03 1.006013691304093015e-18 5.082832053005904230e-19 6.469915507119154094e-20 4.479800762104370913e-32 1.596216636571434816e-21 1.347286713291218265e-27 1.513730340964616692e-25 7.744768116473063993e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.678769601189844350e-20 0.000000000000000000e+00 3.317830935969681285e-21 5.130979768418692608e-19 6.847150370166166795e+03 1.008887827193590308e-18 5.088577890902895859e-19 6.663488174431535925e-20 4.456043725098106974e-32 1.595564530762179609e-21 1.342325442555893690e-27 1.510081773966590979e-25 7.734591485219387719e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.713738915812845523e-20 0.000000000000000000e+00 3.310192868229427846e-21 5.139328714096133641e-19 6.854900360326180817e+03 1.022088770741127122e-18 5.094323730292319492e-19 6.764793229691042143e-20 4.432698919021458333e-32 1.594887347155964847e-21 1.337364196482557363e-27 1.506433215849106188e-25 7.724433762060322338e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.756086898635303905e-20 0.000000000000000000e+00 3.302554819080082497e-21 5.146564233897213790e-19 6.862650369330108333e+03 1.032040508826376934e-18 5.100069599078023645e-19 7.021740246121609427e-20 4.409448892009675179e-32 1.594210161903194522e-21 1.333037521979879959e-27 1.503142195376368755e-25 7.714276014284463335e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.807512353076353459e-20 0.000000000000000000e+00 3.294916751359005602e-21 5.155965364575990942e-19 6.870450368910808720e+03 1.038997858267268054e-18 5.105852546477769972e-19 6.810374532363693205e-20 4.386058166190195895e-32 1.593549241400564360e-21 1.328887863502201759e-27 1.499945405966611926e-25 7.704011479570420013e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.853466414248983162e-20 0.000000000000000000e+00 3.287229415126032577e-21 5.159104459525222970e-19 6.878250368492460439e+03 1.046438583007427256e-18 5.111635509397691125e-19 6.779277565747714960e-20 4.362947056318635439e-32 1.592905552114699968e-21 1.324738212694440528e-27 1.496748616556465255e-25 7.693712482611210503e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.881978908304909279e-20 0.000000000000000000e+00 3.279542078892121789e-21 5.164576470147146932e-19 6.886000358698800483e+03 1.059065358454607178e-18 5.117381410408126368e-19 6.259095658844296661e-20 4.339984122373924778e-32 1.592265989816118341e-21 1.320615174869796251e-27 1.493572323229649225e-25 7.683479517329775294e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.845943006270686137e-20 0.000000000000000000e+00 3.271904029697119487e-21 5.163500005109094927e-19 6.893750367663938050e+03 1.076520970751292480e-18 5.123127340544316381e-19 6.880440829895668862e-20 4.317129486606699199e-32 1.591629196858517097e-21 1.316492134780975977e-27 1.490396022214637290e-25 7.673257284899479235e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.872542893306702803e-20 0.000000000000000000e+00 3.264265962014272302e-21 5.177232000284051033e-19 6.901600376724228227e+03 1.090919929643558119e-18 5.128947427160603846e-19 6.636089715993469614e-20 4.294306312116595672e-32 1.590984510124097262e-21 1.312315902125851410e-27 1.487178736678812104e-25 7.662904406435354191e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.870039458249216662e-20 0.000000000000000000e+00 3.256529338639618730e-21 5.179789781863182969e-19 6.909450366828512415e+03 1.112840521271022278e-18 5.134767515230360788e-19 6.765487689915378681e-20 4.271483192739324278e-32 1.590330402884477259e-21 1.308139687622516318e-27 1.483961458912007704e-25 7.652532708992382536e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.820954870615993418e-20 0.000000000000000000e+00 3.248792733947169850e-21 5.186954836690827789e-19 6.917250366414871678e+03 1.116743543396363664e-18 5.140550554966646812e-19 7.025540142158254519e-20 4.249069927596492703e-32 1.589652142050880670e-21 1.303990076267430778e-27 1.480764669499931799e-25 7.642170422940183134e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.794894800995248906e-20 0.000000000000000000e+00 3.241147481639344645e-21 5.195990581824507207e-19 6.925050366002161354e+03 1.126442858203167712e-18 5.146333609910946197e-19 6.910076430651994601e-20 4.226927993284187058e-32 1.588973881217203207e-21 1.299840473030085986e-27 1.477567880087474546e-25 7.631808136974293228e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.770158647617875447e-20 0.000000000000000000e+00 3.233680223408963460e-21 5.200032247369158238e-19 6.932900375023428751e+03 1.160763894299338114e-18 5.152153758018822780e-19 6.783500505358036775e-20 4.204644096707686547e-32 1.588315834733662031e-21 1.295664273027097547e-27 1.474350594567642513e-25 7.621364239224676979e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.753277450225939927e-20 0.000000000000000000e+00 3.226165089104579319e-21 5.204037247997075536e-19 6.940750365174263607e+03 1.151107222058115625e-18 5.157973907434861277e-19 6.556966317532387707e-20 4.182537506941975826e-32 1.587674249000180387e-21 1.291488091445343572e-27 1.471133316781759747e-25 7.610910198594119497e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.710080260818229145e-20 0.000000000000000000e+00 3.218649972865630585e-21 5.206671126597612464e-19 6.948600374176083278e+03 1.182232012771361975e-18 5.163794086074786453e-19 6.635913966093426581e-20 4.160499866991913094e-32 1.587032661725993157e-21 1.287311908298671308e-27 1.467916031269898346e-25 7.600456132949411805e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.723215026239912214e-20 0.000000000000000000e+00 3.211134838579864394e-21 5.213503877309763803e-19 6.956500373751158804e+03 1.207947924906484628e-18 5.169651344225765304e-19 7.189859606142663788e-20 4.138321886533443282e-32 1.586386988683799631e-21 1.283109138933263938e-27 1.464678257380631511e-25 7.589863374870380693e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.699409346631346232e-20 0.000000000000000000e+00 3.203571846276234280e-21 5.226513129829092175e-19 6.964350363936802751e+03 1.210065211395427825e-18 5.175471539351641175e-19 6.750149299417377882e-20 4.116788044008758933e-32 1.585745402947472915e-21 1.278932983028490480e-27 1.461460979580482101e-25 7.579333854030616698e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.715271297442427745e-20 0.000000000000000000e+00 3.196056730003961692e-21 5.226491000229932965e-19 6.972200372909545877e+03 1.218001599193000358e-18 5.181291763500021750e-19 6.650673486899530441e-20 4.095281170110833006e-32 1.585105684097798729e-21 1.274756825844567121e-27 1.458243694080537733e-25 7.568812111468907924e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.717498739169057077e-20 0.000000000000000000e+00 3.188541595746031583e-21 5.230991505771459151e-19 6.980100372487490858e+03 1.241351628903513639e-18 5.187149067318184404e-19 7.000359056203361306e-20 4.073661086746371984e-32 1.584466160322441231e-21 1.270554082847618866e-27 1.455005920190094714e-25 7.558241193273677452e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.714668644181281701e-20 0.000000000000000000e+00 3.180978603439654386e-21 5.241333801334878313e-19 6.988000372066389900e+03 1.251319884518446490e-18 5.193006386320156294e-19 6.802105770041994949e-20 4.052161544513386214e-32 1.583826636547006620e-21 1.266351348852812478e-27 1.451768146299260936e-25 7.547670275171346769e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.693437422779663179e-20 0.000000000000000000e+00 3.173415611132363877e-21 5.244412520350479023e-19 6.995950381113348158e+03 1.401736650272233628e-18 5.198900799258946033e-19 6.924476329787534318e-20 4.030525903454084203e-32 1.583181069478818642e-21 1.262122019416709576e-27 1.448509876287084197e-25 7.536950179623389719e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.696301380244281004e-20 0.000000000000000000e+00 3.165805454296544174e-21 5.251862844796280454e-19 7.003900371221739078e+03 1.283253402801396342e-18 5.204795213427873449e-19 7.330162213331466983e-20 4.009127744547541365e-32 1.582534419565695812e-21 1.257892709356655330e-27 1.445251614036781375e-25 7.526185395010154087e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.701465960640739053e-20 0.000000000000000000e+00 3.158381825987116659e-21 5.263220478033168587e-19 7.011800370803493934e+03 1.304110617430899135e-18 5.210652577864203472e-19 7.370244891586201205e-20 3.988214291109295454e-32 1.581891913252799177e-21 1.253690003030711955e-27 1.442013840144776924e-25 7.515488637651374041e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.735597930334505904e-20 0.000000000000000000e+00 3.151004878375863394e-21 5.269747617214254120e-19 7.019750379821208298e+03 1.348204434535803080e-18 5.216547036346481274e-19 7.039224379127005862e-20 3.967168449055127800e-32 1.581251391199239250e-21 1.249460701736645134e-27 1.438755570144585865e-25 7.504750508452545196e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.804542030849286201e-20 0.000000000000000000e+00 3.143581232409082080e-21 5.271415266151508527e-19 7.027700369964559286e+03 1.368570413448277986e-18 5.222441495951932531e-19 7.086813940153524415e-20 3.946336411983708346e-32 1.580610870666362574e-21 1.245231420070032020e-27 1.435497307879954640e-25 7.494012404846714774e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.806983724430595008e-20 0.000000000000000000e+00 3.136157604067008923e-21 5.277897840514210333e-19 7.035650378962844115e+03 1.366611175708424910e-18 5.228335984603527356e-19 6.938169094635385970e-20 3.925630415696773277e-32 1.579970348614368030e-21 1.241002138057434593e-27 1.432239037887726637e-25 7.483260767011955382e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.776812713231597883e-20 0.000000000000000000e+00 3.128733958118370847e-21 5.281597342437549979e-19 7.043600369129412684e+03 1.464321017123927251e-18 5.234230474307813340e-19 6.779536685832879140e-20 3.904924468457511757e-32 1.579329828079620720e-21 1.236772875846921629e-27 1.428980775613579876e-25 7.472484986018974250e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.769856712418121694e-20 0.000000000000000000e+00 3.121310329754617437e-21 5.285337304384022679e-19 7.051550378108348923e+03 1.423569167401623915e-18 5.240124992925181355e-19 7.046431599584000027e-20 3.884553088004254385e-32 1.578689306029185163e-21 1.232543613513182827e-27 1.425722505629281639e-25 7.461709179628118294e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.757964613450909600e-20 0.000000000000000000e+00 3.113886683824046615e-21 5.294598204261787722e-19 7.059550377679871417e+03 1.455716282309109013e-18 5.246056592024865885e-19 6.526132670686433803e-20 3.864113449459355469e-32 1.578046903676614137e-21 1.228287767161254576e-27 1.422443747259655549e-25 7.450821782211709073e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.762750026064488998e-20 0.000000000000000000e+00 3.106416357133718052e-21 5.293827654953966754e-19 7.067550377252362523e+03 1.451472073813034793e-18 5.251988206176551896e-19 6.936866672420536283e-20 3.843693644326481282e-32 1.577405394276933257e-21 1.224031931027041204e-27 1.419164988889632500e-25 7.439916158212300678e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.783959982938361767e-20 0.000000000000000000e+00 3.098946030442484829e-21 5.305030646638641792e-19 7.075550376825820422e+03 1.485072092043780717e-18 5.257919835329300466e-19 6.543217879106886871e-20 3.823542294049554662e-32 1.576763884877174701e-21 1.219776105217499493e-27 1.415886230519213181e-25 7.429008409904682777e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.807115437350377003e-20 0.000000000000000000e+00 3.091475703750348449e-21 5.306026432131257867e-19 7.083550376400242385e+03 1.496501183362643905e-18 5.263851479432397044e-19 7.089122289777031810e-20 3.803390943770199853e-32 1.576122375477339032e-21 1.215520289841083041e-27 1.412607472148398740e-25 7.418065050391034870e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.844665959995507118e-20 0.000000000000000000e+00 3.084457986753463590e-21 5.319103779973547949e-19 7.091550375975622956e+03 1.513558680989669832e-18 5.269783138435357230e-19 7.055964380714082056e-20 3.783354676738236522e-32 1.575480866077426439e-21 1.211264485007771669e-27 1.409328713777191472e-25 7.407121690982836328e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.845750631937068372e-20 0.000000000000000000e+00 3.077541335144169497e-21 5.324538837464234893e-19 7.099600384998206209e+03 1.538388038054229944e-18 5.275751892302068975e-19 7.119964786047733688e-20 3.763471515439408224e-32 1.574836588990753625e-21 1.206982087122657567e-27 1.406029459293189293e-25 7.396084634217739691e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.842181509488858019e-20 0.000000000000000000e+00 3.070581446292145979e-21 5.331277757924754109e-19 7.107650375123976119e+03 1.571692801591406095e-18 5.281720647141661343e-19 6.835857191404011007e-20 3.743588400814861129e-32 1.574194101515926779e-21 1.202699710194144684e-27 1.402730212553948403e-25 7.385011210509339656e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.862716636132654032e-20 0.000000000000000000e+00 3.063621573777957707e-21 5.333578050432686778e-19 7.115700384127108009e+03 1.594661659171359706e-18 5.287689430911476518e-19 6.830453523799383273e-20 3.723855925990160767e-32 1.573551612534456222e-21 1.198417334244285195e-27 1.399430958077918233e-25 7.373937760944361509e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.848463727898188607e-20 0.000000000000000000e+00 3.056661684942751469e-21 5.339343051983614419e-19 7.123750374276179173e+03 1.610872995824949348e-18 5.293658215584548022e-19 6.597474564122992229e-20 3.704261600192331654e-32 1.572911418865911044e-21 1.194134979463692106e-27 1.396131711329127371e-25 7.362846391810752712e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.863513913971761689e-20 0.000000000000000000e+00 3.049701812408417293e-21 5.342407024336496078e-19 7.131800383259943374e+03 1.656632562136225443e-18 5.299627029055473169e-19 7.139581583336840486e-20 3.684667228549339532e-32 1.572271932170939045e-21 1.189852625923346719e-27 1.392832456861035002e-25 7.351749454110114992e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.899472239014979681e-20 0.000000000000000000e+00 3.042741923589956114e-21 5.355471909324233915e-19 7.139900382825146153e+03 1.675779041745144586e-18 5.305632923797501588e-19 7.207322122985860875e-20 3.665235336004963319e-32 1.571628474261553876e-21 1.185543690442138878e-27 1.389512714012183596e-25 7.340579397122654805e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.918534047213700085e-20 0.000000000000000000e+00 3.035738813839756226e-21 5.362424499282466146e-19 7.148000382391334824e+03 1.692265998811470573e-18 5.311638833456208909e-19 7.342503338036423302e-20 3.645896587040687783e-32 1.570985016352090278e-21 1.181234766610085435e-27 1.386192971162928114e-25 7.329375697293687699e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.888944888764614156e-20 0.000000000000000000e+00 3.028735704088703963e-21 5.370038036980065189e-19 7.156100381958505750e+03 1.724704725537616259e-18 5.317644757981056804e-19 7.008681160010106249e-20 3.626557838074067260e-32 1.570341558442548628e-21 1.176925854555143369e-27 1.382873228313269933e-25 7.318171997579371730e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.865535413065694099e-20 0.000000000000000000e+00 3.021732594336802335e-21 5.371395355011307090e-19 7.164200381526655292e+03 1.762040943633279802e-18 5.323650697321728426e-19 7.068733862682362321e-20 3.607574217151765779e-32 1.569699504716497069e-21 1.172616954407148521e-27 1.379553485463210891e-25 7.306939718812085381e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.834591787403146225e-20 0.000000000000000000e+00 3.014850453770472630e-21 5.377962863080211597e-19 7.172300381095780722e+03 1.784340744683882878e-18 5.329656651428136117e-19 7.285253887195488225e-20 3.588595018161352792e-32 1.569059039634287047e-21 1.168308066297853080e-27 1.376233742612751675e-25 7.295675106695417820e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.848667315807931511e-20 0.000000000000000000e+00 3.008037263424701498e-21 5.386867602717244210e-19 7.180400380665877492e+03 1.789967154618929939e-18 5.335662620250419475e-19 7.612498581902506071e-20 3.569690629230133222e-32 1.568418574552000288e-21 1.163999190360958587e-27 1.372913999761894352e-25 7.284410494696308159e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.896921091076647579e-20 0.000000000000000000e+00 3.001224073078113726e-21 5.397584483148533163e-19 7.188500380236942874e+03 1.842174106029756666e-18 5.341668603738939583e-19 7.119778592729135509e-20 3.551067798357895991e-32 1.567778109469636980e-21 1.160357526835285778e-27 1.369990076744369043e-25 7.273084484140572922e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.924929223263720251e-20 0.000000000000000000e+00 2.994410882730710820e-21 5.396951305515873170e-19 7.196650389243596692e+03 1.883991061051021580e-18 5.347711682949511559e-19 7.227694724990571152e-20 3.532329990039943622e-32 1.567133690152831826e-21 1.156750854440413540e-27 1.367082194147652970e-25 7.261674510838757698e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.924972429014886278e-20 0.000000000000000000e+00 2.987555627713940953e-21 5.404365037913145501e-19 7.204800379376702040e+03 1.913832822808892898e-18 5.353754762912685921e-19 6.667598101239630013e-20 3.513709936987294341e-32 1.566489784956463246e-21 1.153144197815802649e-27 1.364174318284924804e-25 7.250260674154288192e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.913298296919040984e-20 0.000000000000000000e+00 2.980700388572367115e-21 5.403084136700271332e-19 7.212950388363974525e+03 1.930279916766608911e-18 5.359797871553044785e-19 7.298497906802755493e-20 3.495246199812588532e-32 1.565848349063946344e-21 1.149537540335437753e-27 1.361266435695123944e-25 7.238828062292425012e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.886761867749995131e-20 0.000000000000000000e+00 2.973845133571899568e-21 5.417068381135519075e-19 7.221150387922966729e+03 1.967358135768906477e-18 5.365878062230168074e-19 7.051373528269876826e-20 3.476669209661242694e-32 1.565202978728284938e-21 1.145908767947219801e-27 1.358340716718469258e-25 7.227325325137110984e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.885688904473387483e-20 0.000000000000000000e+00 2.966947829769118769e-21 5.419807705797408415e-19 7.229350387482958467e+03 2.020112512676536958e-18 5.371958267685425605e-19 7.118449197253466088e-20 3.458329094949760368e-32 1.564559186234053971e-21 1.142280003283078980e-27 1.355414997741458020e-25 7.215810615117146974e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.892643843205202681e-20 0.000000000000000000e+00 2.960050525965497257e-21 5.426739881909757437e-19 7.237500377662627216e+03 2.044006278987155508e-18 5.378001406352704008e-19 7.403944781341227634e-20 3.440219601352294684e-32 1.563920707740715740e-21 1.138673377112053292e-27 1.352507121862116354e-25 7.204355599887854029e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.896731723526321074e-20 0.000000000000000000e+00 2.953195286784757075e-21 5.436557944190757324e-19 7.245650386611267095e+03 2.088543325098924328e-18 5.384044573436239036e-19 7.094765657389430036e-20 3.422110066049678597e-32 1.563282227776997516e-21 1.135066750412169581e-27 1.349599239286099313e-25 7.192900558406000304e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.898124276859271726e-20 0.000000000000000000e+00 2.946412126462671555e-21 5.438423343830146997e-19 7.253850386174228333e+03 2.100166444255877513e-18 5.390124822747968222e-19 6.931312947302958999e-20 3.404189070149884959e-32 1.562675201014735573e-21 1.131438009269777264e-27 1.346673520308028524e-25 7.181322955662622704e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.924495169747019149e-20 0.000000000000000000e+00 2.939677768519544503e-21 5.442477676007032642e-19 7.262100395202478467e+03 2.142949906335376787e-18 5.396242168483454148e-19 7.222963969911064753e-20 3.386198260988278807e-32 1.562069695764955809e-21 1.127787145565586586e-27 1.343729958201972577e-25 7.169667020794184411e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.962771473166171499e-20 0.000000000000000000e+00 2.932902339642545597e-21 5.452529447509774220e-19 7.270350385297808316e+03 2.209085063606452656e-18 5.402359514887312876e-19 7.529156703295113337e-20 3.368237505281024862e-32 1.561455703898794942e-21 1.124136298441757537e-27 1.340786402851088461e-25 7.157994136857436210e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.989219892556450903e-20 0.000000000000000000e+00 2.926126926314457836e-21 5.462863348422148276e-19 7.278550384863733598e+03 2.317594024637108043e-18 5.408439807966670569e-19 7.429683559325231518e-20 3.350614699196361296e-32 1.560816254391360300e-21 1.120507581706580097e-27 1.337860683871960186e-25 7.146333628491244500e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.015346670400097416e-20 0.000000000000000000e+00 2.919392568368896288e-21 5.467658846331170225e-19 7.286800393862865349e+03 2.254396543221668094e-18 5.414557197563950457e-19 7.139318235181017381e-20 3.332884416698227770e-32 1.560172905065739886e-21 1.116856742811982240e-27 1.334917121776293589e-25 7.134602006183187850e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.046907106583367926e-20 0.000000000000000000e+00 2.912617139515811639e-21 5.470018955528583865e-19 7.295050383993247124e+03 2.344501817112092718e-18 5.420674587728346418e-19 6.976815511167737302e-20 3.315296672208957818e-32 1.559531248731117733e-21 1.113205920712471573e-27 1.331973566412903085e-25 7.122857873744472478e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.080110252512701083e-20 0.000000000000000000e+00 2.905841726158936492e-21 5.474164928551231797e-19 7.303300392973029375e+03 2.338759744468895825e-18 5.426792006378736926e-19 7.067012963608819382e-20 3.297978827272266669e-32 1.558890837075153039e-21 1.109555098800207922e-27 1.329030004324140451e-25 7.111104478513830858e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.084684165444391529e-20 0.000000000000000000e+00 2.899066297321742646e-21 5.481403561788917257e-19 7.311600392526932410e+03 2.393367099205469032e-18 5.432946507855704175e-19 7.270756247997000103e-20 3.280556045599986715e-32 1.558246544872338701e-21 1.105882163581450438e-27 1.326068605847667396e-25 7.099279864232026499e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.085386761182676834e-20 0.000000000000000000e+00 2.892249813065297886e-21 5.490161432960245429e-19 7.319850382692257881e+03 2.412656186687724012e-18 5.439063941513629329e-19 6.994829761273203919e-20 3.263375729732544561e-32 1.557606134676856713e-21 1.102231367359610981e-27 1.323125050471809075e-25 7.087456629831043615e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.096062860495346035e-20 0.000000000000000000e+00 2.885474399679725255e-21 5.492692826666035766e-19 7.328100391643118201e+03 2.451958647730007114e-18 5.445181403463623293e-19 7.196392024920927483e-20 3.246301798164676884e-32 1.556965723023136930e-21 1.098580571610634826e-27 1.320181488393365537e-25 7.075627892791095147e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.106350211242855754e-20 0.000000000000000000e+00 2.878827180879110472e-21 5.501408588540777668e-19 7.336400391200033482e+03 2.515285370920935486e-18 5.451335948379037176e-19 7.532930602331571869e-20 3.229124407777321504e-32 1.556332698821815750e-21 1.094907662962587635e-27 1.317220089915817776e-25 7.063711103388072099e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.143040341351183284e-20 0.000000000000000000e+00 2.872509132816219377e-21 5.512206302978296465e-19 7.344700390757950117e+03 2.568305249038176891e-18 5.457490507734284151e-19 7.311042655065021688e-20 3.212150507881186604e-32 1.555729062490330950e-21 1.091234763386412357e-27 1.314258691437912546e-25 7.051751602255240446e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.172970303772590378e-20 0.000000000000000000e+00 2.866191084752566186e-21 5.515478832899754927e-19 7.353050399777405801e+03 2.599131089314776016e-18 5.463682164286642146e-19 7.272522048634949799e-20 3.195131011236313671e-32 1.555121789107097818e-21 1.087539742968506619e-27 1.311279449833360431e-25 7.039720042447627277e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.105914490947225661e-20 0.000000000000000000e+00 2.859834968954157589e-21 5.520715069057304283e-19 7.361400389871481821e+03 2.672512958081993438e-18 5.469873821320267886e-19 7.839476572826855037e-20 3.178120947755927901e-32 1.554492277702193661e-21 1.083844740295229613e-27 1.308300214981289367e-25 7.027675101061226343e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.037937999509789623e-20 0.000000000000000000e+00 2.853478867561949479e-21 5.534210828150694913e-19 7.369700389432394331e+03 2.768164446201456607e-18 5.476028423875026774e-19 7.254310719364698582e-20 3.161592500354455515e-32 1.553853816197508107e-21 1.080171868604431010e-27 1.305338816502315401e-25 7.015694602920466211e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.964764934376809408e-20 0.000000000000000000e+00 2.847160819496015640e-21 5.531919842965287642e-19 7.378050398422788930e+03 2.800155795159614758e-18 5.482220123716433166e-19 7.538941836299973571e-20 3.144964465209790306e-32 1.553211507813631614e-21 1.076476876541166087e-27 1.302359574908131973e-25 7.003641919642138999e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.922027823683536834e-20 0.000000000000000000e+00 2.840804703719728530e-21 5.541621938183213076e-19 7.386400388551923243e+03 2.831842345015774226e-18 5.488411823939807318e-19 7.339912871450551327e-20 3.128395099703294641e-32 1.552569200880621342e-21 1.072781902485951945e-27 1.299380340043552455e-25 6.991477946665355919e-22 0.000000000000000000e+00 0.000000000000000000e+00 2.971259143807684501e-20 0.000000000000000000e+00 2.834448602300833501e-21 5.545339007268137497e-19 7.394750397523006541e+03 2.929317877099284270e-18 5.494603552454331611e-19 7.685992589772052775e-20 3.112011806239342181e-32 1.551926892498230297e-21 1.069086929854829945e-27 1.296401098456259215e-25 6.979311915610195823e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.027728585642776937e-20 0.000000000000000000e+00 2.828092486539246653e-21 5.556453346573060140e-19 7.403150397071956831e+03 2.938831491165186327e-18 5.500832364560354240e-19 7.488671525545343072e-20 3.095530427813988379e-32 1.551295487205599592e-21 1.065369845784688747e-27 1.293404020479919117e-25 6.967084731132538596e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.098825233898279796e-20 0.000000000000000000e+00 2.821698317417356382e-21 5.560312157033261528e-19 7.411550396621928485e+03 2.950754766627722121e-18 5.507061191060611643e-19 7.297068192950665134e-20 3.079158025845166552e-32 1.550692796654928908e-21 1.061652771800867355e-27 1.290406942503214661e-25 6.954880293308669980e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.164257678187667062e-20 0.000000000000000000e+00 2.815317240887229666e-21 5.564297054169965026e-19 7.419950396172920591e+03 3.026421650960220211e-18 5.513290031906323867e-19 7.429033892676592158e-20 3.062908371541350714e-32 1.550090106104185062e-21 1.057935708009686342e-27 1.287409864526145848e-25 6.942675855644436318e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.222069668611496234e-20 0.000000000000000000e+00 2.809087492303009792e-21 5.572536884322455146e-19 7.428350395724926784e+03 3.100990361874215605e-18 5.519518887048917996e-19 7.605659038712237698e-20 3.046658717235573059e-32 1.549459654381424439e-21 1.054218654518967577e-27 1.284412786548715433e-25 6.930381978720527497e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.262195228546604290e-20 0.000000000000000000e+00 2.802857743718037602e-21 5.581311864569469924e-19 7.436750395277945245e+03 3.200473029727498412e-18 5.525747756440048373e-19 7.935001792636952656e-20 3.030670192859132589e-32 1.548816411172409640e-21 1.050501611438057001e-27 1.281415708570923875e-25 6.918046891052777169e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.286085504650969473e-20 0.000000000000000000e+00 2.796627995132314977e-21 5.592189574500208114e-19 7.445150394831972335e+03 3.200818368450300170e-18 5.531976640031586008e-19 7.926993383808929685e-20 3.014789168061262368e-32 1.548174971797716230e-21 1.046784578877854227e-27 1.278418630592772322e-25 6.905711704903959888e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.307928393424871929e-20 0.000000000000000000e+00 2.790398246545844172e-21 5.598359375312778531e-19 7.453550394387005326e+03 3.305362635140127179e-18 5.538205537775615692e-19 7.935919023669380355e-20 2.998908143261490540e-32 1.547574971829499679e-21 1.043067556950838366e-27 1.275421552614261921e-25 6.893374252712926146e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.328770434881327374e-20 0.000000000000000000e+00 2.784168497958627446e-21 5.604763865596332673e-19 7.462000403377100156e+03 3.354235824441668317e-18 5.544471533520483554e-19 7.944897822757776321e-20 2.983159249098013497e-32 1.546971399758778661e-21 1.039328416561213619e-27 1.272406631518551295e-25 6.880963349615496284e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.312750473389939075e-20 0.000000000000000000e+00 2.777901660535228867e-21 5.610987443456099654e-19 7.470450393494803393e+03 3.409303230410834580e-18 5.550737529494878933e-19 7.953876622175070567e-20 2.967429267494289776e-32 1.546353318350840922e-21 1.035589295516493993e-27 1.269391717156416004e-25 6.868508942520984376e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.281334316612196699e-20 0.000000000000000000e+00 2.771634837108289555e-21 5.617121566849587126e-19 7.478900402465592379e+03 3.508367760795142116e-18 5.557003553625589134e-19 7.962855461938689272e-20 2.951742753620347884e-32 1.545712023027164988e-21 1.031850177242670472e-27 1.266376796067593729e-25 6.855984870472591424e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.253817150393600062e-20 0.000000000000000000e+00 2.765367999699209061e-21 5.623280455364110318e-19 7.487400402008696801e+03 3.590207450790886553e-18 5.563306662045447497e-19 7.971887441282219316e-20 2.936204031051336494e-32 1.545066933776125772e-21 1.028088949538664659e-27 1.263344038591705028e-25 6.843386705719490508e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.226943226988941833e-20 0.000000000000000000e+00 2.759064087443252956e-21 5.629482155066852576e-19 7.495850392161431046e+03 3.663759939312091612e-18 5.569572700513472576e-19 7.980866301590357462e-20 2.920756729904039837e-32 1.544455527668520547e-21 1.024349862251637402e-27 1.260329124217070926e-25 6.830848276151166424e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.164194339293413421e-20 0.000000000000000000e+00 2.752797263990333526e-21 5.635445552728445909e-19 7.504300401103357217e+03 3.707352991876160789e-18 5.575838766947191634e-19 7.989845201971670239e-20 2.905420975648556267e-32 1.543854638143761401e-21 1.020610778133702629e-27 1.257314203138546624e-25 6.818304756323938145e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.101016410101301694e-20 0.000000000000000000e+00 2.746657236257160787e-21 5.641414405701473032e-19 7.512800400649548465e+03 3.764201849369735102e-18 5.582141917800187201e-19 7.998877242119359281e-20 2.890178603580979407e-32 1.543247080839811924e-21 1.016849585152056141e-27 1.254281445661556815e-25 6.805677690055428042e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.101832150172294491e-20 0.000000000000000000e+00 2.740496687470180502e-21 5.647776367677847082e-19 7.521300400196764713e+03 3.856651466187016737e-18 5.588445082757467826e-19 8.007909302477651232e-20 2.874936231511563891e-32 1.542604858651799958e-21 1.013138558736755503e-27 1.251279683077134228e-25 6.792946629727538477e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.125172505016586034e-20 0.000000000000000000e+00 2.734336138682457303e-21 5.654262405949756127e-19 7.529850409204686912e+03 3.978697517174752153e-18 5.594785346353278405e-19 8.016994522977661591e-20 2.859773541264997837e-32 1.541958857971201372e-21 1.009994214381212612e-27 1.248623948408697371e-25 6.780140666825343962e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.273087860151864906e-20 0.000000000000000000e+00 2.728139344513682263e-21 5.661493101067592517e-19 7.538400399288963854e+03 4.052631678650046209e-18 5.601125610089647203e-19 8.026079743679084499e-20 2.844722672644068319e-32 1.541330945183082287e-21 1.006849884123591795e-27 1.245968219618170323e-25 6.767309471300467253e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.388038912098554831e-20 0.000000000000000000e+00 2.721942564060207050e-21 5.668562428071116884e-19 7.546900398839248737e+03 4.128312743467736506e-18 5.607428817238599639e-19 8.035111864495530097e-20 2.829759804237406422e-32 1.540729175303416036e-21 1.003723945444791178e-27 1.243328018483122086e-25 6.754521912258235117e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.417851734404570920e-20 0.000000000000000000e+00 2.715782015270259628e-21 5.675096988363599710e-19 7.555450407818186250e+03 4.238443793898256955e-18 5.613769123107000939e-19 8.044197145569648325e-20 2.814899293115143880e-32 1.540123864933225832e-21 1.000579622675064533e-27 1.240672283823688322e-25 6.741659118286644834e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.408849209448949160e-20 0.000000000000000000e+00 2.709585221122491895e-21 5.681435928299575874e-19 7.564000397937588787e+03 4.344163176357367183e-18 5.620109429020105961e-19 8.053282426707824187e-20 2.800079310241513185e-32 1.539520676797350543e-21 9.974353141830413976e-28 1.238016555022250758e-25 6.728781506649957813e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.342090402685625196e-20 0.000000000000000000e+00 2.703388440643558671e-21 5.687432845757457225e-19 7.572550406897269568e+03 4.432892870884271467e-18 5.626449762887047013e-19 8.062367747902183163e-20 2.785273172795069390e-32 1.538918032994025084e-21 9.942910061740514481e-28 1.235360820368798239e-25 6.715900047218470938e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.305783890160185313e-20 0.000000000000000000e+00 2.697191646509747912e-21 5.693614507240920094e-19 7.581150406435689547e+03 4.539797234104838428e-18 5.632827181762400765e-19 8.071506209707114886e-20 2.770631492908649512e-32 1.538306767941198530e-21 9.911283214310006564e-28 1.232689558045967837e-25 6.702935082003493960e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.296371036312389170e-20 0.000000000000000000e+00 2.690958620679977377e-21 5.699991271797390015e-19 7.589750405975152717e+03 4.647545156386598966e-18 5.639204614689621540e-19 8.080644691647537049e-20 2.755989813020453927e-32 1.537665539905361315e-21 9.879656443302173532e-28 1.230018295722813716e-25 6.689921977606535665e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.335770840024868209e-20 0.000000000000000000e+00 2.685043630770940191e-21 5.706651617731153431e-19 7.598350405515661805e+03 4.781515040771251999e-18 5.645582061621093609e-19 8.089783193655218767e-20 2.741414026388041944e-32 1.537024311869446235e-21 9.848029749453331587e-28 1.227347033399334496e-25 6.676908873413811521e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.399400513403089873e-20 0.000000000000000000e+00 2.679261014629616646e-21 5.713457853493992174e-19 7.606950405057207718e+03 4.868933090189248201e-18 5.651959522509406355e-19 8.098921715662221658e-20 2.727003606988174005e-32 1.536401725960897625e-21 9.816403133509328451e-28 1.224675771075533164e-25 6.663839843273351561e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.466631331134757542e-20 0.000000000000000000e+00 2.673478398487595703e-21 5.720292152501748334e-19 7.615550404599787726e+03 5.001807648363498688e-18 5.658336997307367753e-19 8.108060257600922711e-20 2.712593187586573602e-32 1.535798217221067558e-21 9.784776596225629460e-28 1.222004508751410637e-25 6.650713582070393306e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.534804725151738670e-20 0.000000000000000000e+00 2.667695782344879244e-21 5.727139267613765871e-19 7.624150404143402739e+03 5.139756906327216779e-18 5.664714485968002445e-19 8.117198819404011878e-20 2.698341337204818866e-32 1.535194708481164704e-21 9.753150138367486173e-28 1.219333246426966685e-25 6.637587321078992061e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.551709671394647615e-20 0.000000000000000000e+00 2.661913166201466892e-21 5.733673700882228697e-19 7.632800413129290973e+03 5.265891460948576557e-18 5.671129073990929639e-19 8.126390542385927911e-20 2.684155322467962430e-32 1.534589927466948970e-21 9.721339851927724452e-28 1.216646450573906345e-25 6.624337750247014360e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.561317408485333502e-20 0.000000000000000000e+00 2.656096923846013238e-21 5.740200509280347309e-19 7.641450403228433970e+03 5.357428193374571378e-18 5.677543661936873561e-19 8.135582265257531493e-20 2.669969338705367837e-32 1.533985561346484908e-21 9.689529716882648869e-28 1.213959660587294286e-25 6.611079523562289624e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.526712229657200074e-20 0.000000000000000000e+00 2.650280694189955061e-21 5.746454335412003220e-19 7.650100412195036370e+03 5.442867753941362947e-18 5.683958277756125567e-19 8.144774028069928503e-20 2.655943334305015903e-32 1.533373768527006039e-21 9.657719595201725801e-28 1.211272864740224376e-25 6.597798992130759588e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.497253981067443466e-20 0.000000000000000000e+00 2.644464451847468708e-21 5.752742039299575737e-19 7.658750402317600674e+03 5.623808831256887982e-18 5.690372893435899801e-19 8.153965790682460930e-20 2.641973600257074242e-32 1.532731629522274217e-21 9.625909626388096163e-28 1.208586074746337338e-25 6.584427447682266978e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.484106099859705873e-20 0.000000000000000000e+00 2.638648222175662293e-21 5.759130119072860240e-19 7.667400411264998183e+03 5.831828264257300121e-18 5.696787536863751412e-19 8.163157593056337060e-20 2.628003835807027469e-32 1.532089489120065810e-21 9.594099672747337073e-28 1.205899278905232832e-25 6.571055874361424123e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.503878052956803170e-20 0.000000000000000000e+00 2.632831979846089450e-21 5.765717853153869076e-19 7.676100410798875600e+03 6.114440984808072395e-18 5.703239265996958733e-19 8.172402537039464873e-20 2.614204826036636724e-32 1.531466058379208664e-21 9.562105967334920145e-28 1.203196955392345960e-25 6.557576673657173449e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.575179751817928168e-20 0.000000000000000000e+00 2.627056270368861615e-21 5.772660265698004087e-19 7.684800410333808031e+03 6.236808698502716925e-18 5.709691008984660888e-19 8.181647500875259109e-20 2.600414785280022207e-32 1.530860841020256857e-21 9.530112349018007100e-28 1.200494631879131465e-25 6.544072818590503258e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.638120194205708188e-20 0.000000000000000000e+00 2.621349154075413481e-21 5.779557810711961762e-19 7.693500409869793657e+03 6.284077988143501766e-18 5.716142765779948000e-19 8.190892484496502405e-20 2.586675230268635284e-32 1.530255623661231700e-21 9.498118818676767626e-28 1.197792308365589805e-25 6.530568963758981777e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.694282336888599728e-20 0.000000000000000000e+00 2.615642037781274345e-21 5.786418020713461251e-19 7.702200409406825202e+03 6.409456969631738519e-18 5.722594536336116269e-19 8.200137487836267491e-20 2.573143495451533120e-32 1.529652785495631243e-21 9.466125377203279537e-28 1.195089984851723278e-25 6.517015592411556918e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.678426965673116061e-20 0.000000000000000000e+00 2.609934921486449473e-21 5.792821131038275511e-19 7.710900408944903575e+03 6.590341760211104468e-18 5.729046320606680486e-19 8.209382510827946082e-20 2.559611760632802493e-32 1.529050188125028345e-21 9.434132025501699166e-28 1.192387661337531653e-25 6.503457209778166730e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.633395348789319411e-20 0.000000000000000000e+00 2.604227805190937736e-21 5.799041409405943568e-19 7.719650417926967748e+03 6.729431480683439406e-18 5.735535204887991076e-19 8.218680695927650145e-20 2.546086715011075199e-32 1.528444798763657484e-21 9.401954860701186564e-28 1.189669804294191683e-25 6.489806907760966015e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.637490509925085321e-20 0.000000000000000000e+00 2.598487883179580577e-21 5.805608971356659462e-19 7.728400408018898815e+03 6.976749529482946523e-18 5.742024088938646519e-19 8.227978880696839352e-20 2.532679705399141126e-32 1.527841351171110470e-21 9.369777858049678750e-28 1.186951953118352198e-25 6.476116249773658890e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.652798212664410745e-20 0.000000000000000000e+00 2.592747973559969643e-21 5.812246893809314779e-19 7.737150416981694434e+03 7.188632811806778356e-18 5.748513000715075144e-19 8.237277105195411454e-20 2.519272666872676054e-32 1.527237902277124572e-21 9.337600879643940089e-28 1.184234096080997377e-25 6.462425562511206626e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.753895653442438155e-20 0.000000000000000000e+00 2.587008051561252528e-21 5.819432159223938559e-19 7.745900407097078642e+03 7.363738929877231024e-18 5.755001912199366197e-19 8.246575329275367035e-20 2.506058734284049147e-32 1.526611608100645155e-21 9.305424065159236687e-28 1.181516244897872811e-25 6.448666365543979278e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.835607871942779011e-20 0.000000000000000000e+00 2.581268141926256724e-21 5.826505545146861065e-19 7.754650416040687560e+03 7.602415682971354880e-18 5.761490851285182915e-19 8.255873592906667733e-20 2.492948065145592861e-32 1.525970443652191005e-21 9.273247277033779793e-28 1.178798387866477654e-25 6.434862532649671969e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.846852864346541938e-20 0.000000000000000000e+00 2.575528219940125862e-21 5.833120235985245961e-19 7.763450415569097459e+03 7.896005169029646086e-18 5.768016876712073039e-19 8.265224999058164514e-20 2.479762492081713183e-32 1.525325616100540346e-21 9.240886753785776860e-28 1.176065003163821757e-25 6.420979835906570533e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.805065355239972812e-20 0.000000000000000000e+00 2.569797921711220671e-21 5.839424426551397783e-19 7.772250415098576923e+03 8.042800330361625902e-18 5.774542915841577236e-19 8.274576424844691616e-20 2.466739960649479142e-32 1.524719713984647190e-21 9.208526329266785017e-28 1.173331618460833415e-25 6.407045551728349844e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.680730322469423724e-20 0.000000000000000000e+00 2.564151864095147576e-21 5.845206652360758952e-19 7.781050414629119587e+03 8.414911741772408635e-18 5.781068968627286370e-19 8.283927870199747880e-20 2.453741928556005330e-32 1.524115422171391006e-21 9.176166004521397158e-28 1.170598233757514924e-25 6.393109133690463812e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.614678093891844182e-20 0.000000000000000000e+00 2.558505806478392506e-21 5.851374177632178330e-19 7.789850414160724540e+03 8.426181064973444468e-18 5.787595035023007976e-19 8.293279335057142707e-20 2.440768461452142591e-32 1.523511937493283684e-21 9.143805780608966225e-28 1.167864849053866515e-25 6.379144314977746441e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.592069642415133396e-20 0.000000000000000000e+00 2.552859748860955461e-21 5.857814888293338746e-19 7.798650413693385417e+03 8.889403227205693322e-18 5.794121114982749884e-19 8.302630819350971978e-20 2.428024625394232087e-32 1.522910228123529206e-21 9.111445658603913711e-28 1.165131464349890023e-25 6.365117028152064584e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.573267676872021253e-20 0.000000000000000000e+00 2.547213691242841332e-21 5.864280004335605542e-19 7.807500422670498665e+03 9.232674449096571015e-18 5.800684295581059548e-19 8.312035466652455079e-20 2.415208367495947254e-32 1.522305099304581351e-21 9.078901741412313348e-28 1.162382546116620545e-25 6.351010026054302988e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.555524346457969766e-20 0.000000000000000000e+00 2.541535547690656265e-21 5.870789826222484909e-19 7.816350412756582955e+03 9.569544348199866212e-18 5.807247475794889076e-19 8.321440113403001845e-20 2.402447981776310082e-32 1.521699971777327627e-21 9.046357998987179545e-28 1.159633633751129584e-25 6.336853051050456514e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.555323430277051159e-20 0.000000000000000000e+00 2.535857416258908061e-21 5.877406308716992992e-19 7.825200421714450385e+03 9.694947191927170506e-18 5.813810683583112732e-19 8.330844799666014017e-20 2.389805111836499513e-32 1.521094842959695574e-21 9.013814293605245538e-28 1.156884715523837908e-25 6.322670408793734168e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.576273867903559069e-20 0.000000000000000000e+00 2.530179272719070762e-21 5.884151025672151286e-19 7.834050411824013281e+03 1.016183822826431011e-17 5.820373890926403237e-19 8.340249485291463934e-20 2.377162268822838184e-32 1.520489759194960721e-21 8.981270765129798058e-28 1.154135803151054290e-25 6.308485622512111439e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.726113389699392282e-20 0.000000000000000000e+00 2.524501141272258551e-21 5.891697323469694131e-19 7.842900420762716749e+03 1.055299403435478211e-17 5.826937125720856278e-19 8.349654210252796758e-20 2.364679250692369314e-32 1.519887205394878783e-21 8.948727276185743460e-28 1.151386884929715391e-25 6.294175035335492507e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.858953816576578119e-20 0.000000000000000000e+00 2.518822997744717112e-21 5.899168063064356082e-19 7.851800420285782820e+03 1.076226162850222404e-17 5.833537447473582606e-19 8.359112078618736770e-20 2.352255283746809695e-32 1.519281247980542483e-21 8.916000071428888581e-28 1.148622439037251668e-25 6.279783612992148434e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.957159269575325847e-20 0.000000000000000000e+00 2.513174462290439853e-21 5.906470998419948416e-19 7.860700419809929372e+03 1.112354040659598189e-17 5.840137782775152907e-19 8.368569966399363865e-20 2.339831316799742038e-32 1.518676242724750475e-21 8.883272979104748291e-28 1.145857993144452515e-25 6.265386835083991496e-22 0.000000000000000000e+00 0.000000000000000000e+00 4.012643698973146791e-20 0.000000000000000000e+00 2.507872637087383914e-21 5.913497347975654445e-19 7.869600419335152765e+03 1.161401324958080061e-17 5.846738131579680938e-19 8.378027873528924388e-20 2.327552621837174203e-32 1.518072852926430256e-21 8.850546000460626198e-28 1.143093547251318623e-25 6.250980970574382775e-22 0.000000000000000000e+00 0.000000000000000000e+00 4.029798916122770094e-20 0.000000000000000000e+00 2.502570811883686626e-21 5.920265948262620157e-19 7.878500418861446633e+03 1.218156023143439096e-17 5.853338493841483640e-19 8.387485799941961997e-20 2.315316023298188869e-32 1.517469463128037438e-21 8.819193948735339997e-28 1.140418429621132344e-25 6.236575106372224132e-22 0.000000000000000000e+00 0.000000000000000000e+00 4.022752980434398188e-20 0.000000000000000000e+00 2.497268986679351749e-21 5.926870077942606557e-19 7.887400418388811886e+03 1.265333922037058625e-17 5.859938869515094622e-19 8.396943745573321280e-20 2.303079435175103464e-32 1.516867904243793259e-21 8.791974319798100900e-28 1.138011810154046988e-25 6.222077926062035184e-22 0.000000000000000000e+00 0.000000000000000000e+00 4.006736420666696675e-20 0.000000000000000000e+00 2.491967161474378532e-21 5.933413803003827861e-19 7.896300417917241248e+03 1.311428659180461003e-17 5.866539258555241049e-19 8.406401710358130897e-20 2.291064435811724029e-32 1.516267060393772715e-21 8.764754759125610198e-28 1.135605190686673957e-25 6.207545083900507288e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.934460351408602118e-20 0.000000000000000000e+00 2.486665336268771489e-21 5.939582926649280180e-19 7.905250426878751568e+03 1.358625133969906799e-17 5.873176748863473362e-19 8.415912839052655393e-20 2.278981923713685058e-32 1.515662840379493496e-21 8.737382320204005891e-28 1.133185048333729966e-25 6.192923614078894122e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.863638342086226779e-20 0.000000000000000000e+00 2.481333719907335594e-21 5.945808759312051299e-19 7.914200416972014864e+03 1.419671433053550825e-17 5.879814238603809600e-19 8.425423966933420321e-20 2.266938154835625100e-32 1.515058621639020016e-21 8.710010009327794443e-28 1.130764911082886272e-25 6.178195852316670106e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.830572796836866056e-20 0.000000000000000000e+00 2.476002114785917249e-21 5.952285848247522922e-19 7.923150425914345760e+03 1.454837305553128221e-17 5.886451755702742404e-19 8.434935134017426955e-20 2.255028868743007482e-32 1.514454401626035721e-21 8.682637711809007482e-28 1.128344768735128461e-25 6.163468059871852411e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.779420108334372213e-20 0.000000000000000000e+00 2.470670498435906783e-21 5.958650309402623371e-19 7.932150425431093936e+03 1.528553437752117560e-17 5.893126360321929075e-19 8.444499445311326253e-20 2.243053062934431455e-32 1.513847870559254041e-21 8.655112597687915028e-28 1.125911108601308618e-25 6.148636662056321073e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.694517105985536575e-20 0.000000000000000000e+00 2.465309102164375686e-21 5.964847301329056611e-19 7.941150424948936234e+03 1.617253748640063140e-17 5.899800978380100823e-19 8.454063775862490732e-20 2.231201127226423925e-32 1.513242828574861369e-21 8.627587556738605197e-28 1.123477448467192836e-25 6.133775390010914633e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.665932908047839808e-20 0.000000000000000000e+00 2.459947705892193084e-21 5.971400666215639156e-19 7.950150424467871744e+03 1.730884166174825154e-17 5.906475609831697850e-19 8.463628125605636181e-20 2.219493927852192329e-32 1.512637786590395157e-21 8.600062589663684106e-28 1.121043788332781574e-25 6.118914118311966815e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.679577320421843023e-20 0.000000000000000000e+00 2.454706362853980150e-21 5.978214268436952269e-19 7.959150423987893191e+03 1.808604564523543332e-17 5.913150254631367395e-19 8.473192494475773298e-20 2.207786728476548486e-32 1.512034699649346058e-21 8.572537697174801518e-28 1.118610128198076667e-25 6.103984542963648531e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.765568966000450471e-20 0.000000000000000000e+00 2.449469178057896503e-21 5.985478829146064698e-19 7.968150423509001484e+03 1.925038456115891871e-17 5.919824912733956029e-19 8.482756882408205281e-20 2.196197617230863628e-32 1.511432189221154745e-21 8.545012879992745901e-28 1.116176468063077657e-25 6.089034826148501457e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.868779425236578485e-20 0.000000000000000000e+00 2.444231993261180157e-21 5.992865435597037659e-19 7.977150423031189348e+03 1.970225422169756576e-17 5.926499584094521215e-19 8.492321289338526625e-20 2.184663217843227750e-32 1.510829678792891210e-21 8.517488138847652497e-28 1.113742807927786840e-25 6.074063134422960813e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.872148883686616064e-20 0.000000000000000000e+00 2.438994808463836003e-21 5.999615647964794156e-19 7.986150422554453144e+03 2.094103639828332696e-17 5.933174268668312045e-19 8.501885715202614697e-20 2.173128818454212742e-32 1.510227168364555453e-21 8.489963474479103768e-28 1.111309147792205133e-25 6.058925134752233374e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.865768240073389928e-20 0.000000000000000000e+00 2.433757623665865547e-21 6.006303044069048909e-19 7.995200431508894326e+03 2.179437170377987966e-17 5.939886055097256503e-19 8.511503305817654219e-20 2.161729019186426241e-32 1.509621310024509205e-21 8.462285944634912341e-28 1.108861964771567204e-25 6.043703019593689282e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.828046629761393069e-20 0.000000000000000000e+00 2.428491337907162873e-21 6.012827689348813351e-19 8.004300431018315976e+03 2.209542311394249278e-17 5.946634929557366487e-19 8.521174041374690156e-20 2.150286948090117927e-32 1.509299999999999980e-21 8.434455609121429444e-28 1.106401263970122990e-25 6.035630145494931135e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.801361036871672706e-20 0.000000000000000000e+00 2.423195962171965484e-21 6.019462262406897474e-19 8.013350421120160718e+03 2.217275248812969764e-17 5.953346728571679575e-19 8.530791650023812676e-20 2.138935829156373564e-32 1.509299999999999980e-21 8.406778296488673638e-28 1.103954086047353350e-25 6.035630145494931135e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.787362750648995518e-20 0.000000000000000000e+00 2.417929687383766777e-21 6.026140669141826536e-19 8.022400430045860048e+03 2.222878512650317028e-17 5.960058554726169514e-19 8.540409297563196434e-20 2.127759786387811263e-32 1.509299999999999980e-21 8.379101007030657304e-28 1.101506903034487459e-25 6.035630145494931135e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.785627950095783330e-20 0.000000000000000000e+00 2.412663401641789225e-21 6.032896484871883510e-19 8.031500429558602264e+03 2.214424993773866912e-17 5.966807469019764685e-19 8.550080090199246836e-20 2.116522009211758064e-32 1.509299999999999980e-21 8.351270915533746568e-28 1.099046202232145323e-25 6.035630145494931135e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.789002977868529936e-20 0.000000000000000000e+00 2.407368025904659512e-21 6.039721787720350699e-19 8.040600429072446786e+03 2.223773646498307592e-17 5.973556396549946066e-19 8.559750901802537833e-20 2.105341858573703832e-32 1.509299999999999980e-21 8.323440907309900633e-28 1.096585501429505181e-25 6.035630145494931135e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.860815021523165713e-20 0.000000000000000000e+00 2.402160268302526066e-21 6.046980202460810055e-19 8.049700428587390888e+03 2.233336827399440373e-17 5.980305337271903046e-19 8.569421732308857715e-20 2.094262970275351030e-32 1.509299999999999980e-21 8.295610983197251131e-28 1.094124800626567492e-25 6.035630145494931135e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.930708285353456068e-20 0.000000000000000000e+00 2.396977216349311869e-21 6.054233664880217557e-19 8.058800428103428203e+03 2.241047393931112160e-17 5.987054291141018569e-19 8.579092581654276442e-20 2.083184081975667543e-32 1.509299999999999980e-21 8.267781144045226179e-28 1.091664099823334551e-25 6.035630145494931135e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.974388951083309547e-20 0.000000000000000000e+00 2.391794164395475131e-21 6.061321749509333941e-19 8.067900427620559640e+03 2.245018083159284554e-17 5.993803258112887431e-19 8.588763449775158881e-20 2.072259019128310866e-32 1.509299999999999980e-21 8.239951390714702838e-28 1.089203399019805442e-25 6.035630145494931135e-22 0.000000000000000000e+00 0.000000000000000000e+00 4.026755591020958914e-20 0.000000000000000000e+00 2.386611112441015099e-21 6.068469946993758655e-19 8.077050436576460925e+03 2.246533341961371635e-17 6.000589327488538029e-19 8.598487483433141725e-20 2.061379874621688011e-32 1.509299999999999980e-21 8.211968785192697368e-28 1.086729175329167127e-25 6.035630145494931135e-22 0.000000000000000000e+00 0.000000000000000000e+00 4.091104403690855470e-20 0.000000000000000000e+00 2.381399576801598038e-21 6.075739858938313126e-19 8.086200426652804708e+03 2.226452611768503092e-17 6.007375396019102123e-19 8.608211515880168431e-20 2.050500752562413255e-32 1.509299999999999980e-21 8.183986325960002454e-28 1.084254956743687691e-25 6.035630145494931135e-22 0.000000000000000000e+00 0.000000000000000000e+00 4.104806205090955261e-20 0.000000000000000000e+00 2.376188051915338106e-21 6.082671731893622424e-19 8.095350435589555673e+03 2.238578327388618978e-17 6.014161491649802021e-19 8.617935587160075699e-20 2.039738937772883544e-32 1.509299999999999980e-21 8.156003898511868715e-28 1.081780733058227750e-25 6.035630145494931135e-22 0.000000000000000000e+00 0.000000000000000000e+00 4.094341357801600680e-20 0.000000000000000000e+00 2.370976516286828128e-21 6.089440801705467283e-19 8.104550435095089597e+03 2.216700022469976809e-17 6.020984675914657814e-19 8.627712804246032204e-20 2.028945237565603698e-32 1.509299999999999980e-21 8.127868681747149066e-28 1.079292991588229329e-25 6.035630145494931135e-22 0.000000000000000000e+00 0.000000000000000000e+00 4.047842881586310158e-20 0.000000000000000000e+00 2.365736507721067343e-21 6.096007297261753918e-19 8.113700425206738146e+03 2.240258900853182544e-17 6.027770783746638133e-19 8.637436893009649471e-20 2.018218961409026363e-32 1.509299999999999980e-21 8.099886494082417738e-28 1.076818772993203134e-25 6.035630145494931135e-22 0.000000000000000000e+00 0.000000000000000000e+00 4.000503903663179909e-20 0.000000000000000000e+00 2.360524982814699124e-21 6.102535172559836251e-19 8.122850434114862765e+03 2.236033948326007378e-17 6.034556918498770325e-19 8.647161020348241206e-20 2.007683892328926855e-32 1.509299999999999980e-21 8.071904341214024966e-28 1.074344549315484007e-25 6.035630145494931135e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.960806020016199016e-20 0.000000000000000000e+00 2.355313447202494099e-21 6.109116954243592570e-19 8.132050433623736353e+03 2.256249991494523900e-17 6.041380141989483296e-19 8.656938293642516100e-20 1.997091265443415902e-32 1.509299999999999980e-21 8.043769403309218950e-28 1.071856807844582384e-25 6.035630145494931135e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.935553913502687900e-20 0.000000000000000000e+00 2.350292707960906246e-21 6.115832100977575505e-19 8.141250433133721344e+03 2.257468692963804068e-17 6.048203378514479907e-19 8.666715585614144224e-20 1.986551776319249254e-32 1.509299999999999980e-21 8.015634560657457668e-28 1.069369066373380459e-25 6.035630145494931135e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.929003793701829879e-20 0.000000000000000000e+00 2.345424121037553365e-21 6.122668432580244387e-19 8.150500442099655629e+03 2.252340602727407851e-17 6.055063717957133920e-19 8.676546043859225586e-20 1.976102156815545209e-32 1.509299999999999980e-21 7.987346879377650692e-28 1.066867802010423601e-25 6.035630145494931135e-22 0.000000000000000000e+00 0.000000000000000000e+00 3.963472885017487177e-20 0.000000000000000000e+00 2.340529069397217354e-21 6.129806224445395582e-19 8.159750432151709902e+03 3.176834076629317207e-17 6.061924056458541672e-19 8.686376500755557745e-20 1.965652558678614899e-32 1.509299999999999980e-21 7.959059354288555238e-28 1.064366542761906746e-25 6.035630145494931135e-22 0.000000000000000000e+00 0.000000000000000000e+00 4.015427741638580091e-20 0.000000000000000000e+00 2.335634027765997569e-21 6.137059636258662457e-19 8.168950431665012729e+03 2.253817517527425340e-17 6.068747331962794577e-19 8.696153848582140652e-20 1.955337644772672853e-32 1.509299999999999980e-21 7.930924804567076860e-28 1.061878801289807588e-25 6.035630145494931135e-22 0.000000000000000000e+00 0.000000000000000000e+00 4.070918286466247064e-20 0.000000000000000000e+00 2.330765440840889158e-21 6.144302753606294698e-19 8.178200440602240633e+03 2.281561160483859156e-17 6.075607710440283370e-19 8.705984362761820018e-20 1.945047009830006963e-32 1.509299999999999980e-21 7.902637421051029835e-28 1.059377536934613125e-25 6.035630145494931135e-22 0.000000000000000000e+00 0.000000000000000000e+00 4.107907485451853585e-20 0.000000000000000000e+00 2.325870389215744296e-21 6.151463640653856908e-19 8.187450430689642417e+03 2.329633803525953538e-17 6.082468087891650169e-19 8.715814875471125297e-20 1.934756395857772866e-32 1.509299999999999980e-21 7.874350196725925910e-28 1.056876277676538032e-25 6.035630145494931135e-22 0.000000000000000000e+00 0.000000000000000000e+00 4.083970857844993288e-20 0.000000000000000000e+00 2.320975347565818917e-21 6.158219176796990301e-19