2016-07-07_23:56:00.649470Z ISC_LOCK [ANALOG_CARM.run] timer['sleep'] done 2016-07-07_23:56:00.673200Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-REFL_SUM_A_IN2GAIN => 10 2016-07-07_23:56:00.674250Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:ALS-C_REFL_DC_BIAS_SW1 => 16 2016-07-07_23:56:00.926270Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:ALS-C_REFL_DC_BIAS => ON: FM1 2016-07-07_23:56:00.938370Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-REFL_SUM_A_IN2GAIN => 16 2016-07-07_23:56:01.442420Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-REFL_SERVO_COMCOMP => 1 2016-07-07_23:56:02.447080Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:ALS-C_REFL_DC_BIAS_TRAMP => 2 2016-07-07_23:56:02.948230Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:ALS-C_REFL_DC_BIAS_GAIN => 0 2016-07-07_23:56:03.462200Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-REFL_SUM_A_IN1EN => 0 2016-07-07_23:56:03.462230Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-MCL_TRAMP => 1 2016-07-07_23:56:03.474670Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-REFL_SERVO_IN1GAIN => -13 2016-07-07_23:56:03.489770Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-REFL_SERVO_FASTGAIN => 4 2016-07-07_23:56:03.492010Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-MCL_GAIN => 169.906988252 2016-07-07_23:56:04.499300Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-REFL_SERVO_IN1GAIN => -10 2016-07-07_23:56:04.503180Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-REFL_SERVO_FASTGAIN => 1 2016-07-07_23:56:04.507560Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-MCL_GAIN => 120.284936071 2016-07-07_23:56:05.521030Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-REFL_SERVO_IN1GAIN => -7 2016-07-07_23:56:05.533330Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-REFL_SERVO_FASTGAIN => -2 2016-07-07_23:56:05.537210Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-MCL_GAIN => 85.1552134161 2016-07-07_23:56:06.551930Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-REFL_SERVO_IN1GAIN => -4 2016-07-07_23:56:06.557750Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:IMC-REFL_SERVO_FASTGAIN => -3 2016-07-07_23:56:07.570380Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-REFL_SERVO_IN1GAIN => -1 2016-07-07_23:56:07.582310Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:IMC-REFL_SERVO_FASTGAIN => -6 2016-07-07_23:56:07.583860Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-MCL_TRAMP => 0.2 2016-07-07_23:56:07.597250Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-REFL_SERVO_IN1GAIN => 0 2016-07-07_23:56:07.608200Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:IMC-REFL_SERVO_IN2GAIN => -7 2016-07-07_23:56:07.609780Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-MCL_GAIN => 75.894663844 2016-07-07_23:56:07.824790Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-REFL_SERVO_IN1GAIN => 1 2016-07-07_23:56:07.836560Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:IMC-REFL_SERVO_IN2GAIN => -8 2016-07-07_23:56:07.838240Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-MCL_GAIN => 67.6411903503 2016-07-07_23:56:08.041090Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-REFL_SERVO_IN1GAIN => 2 2016-07-07_23:56:08.054110Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:IMC-REFL_SERVO_IN2GAIN => -9 2016-07-07_23:56:08.058450Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-MCL_GAIN => 60.2852743562 2016-07-07_23:56:08.270310Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-REFL_SERVO_IN1GAIN => 3 2016-07-07_23:56:08.286830Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:IMC-REFL_SERVO_IN2GAIN => -10 2016-07-07_23:56:08.290440Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-MCL_GAIN => 53.7293073256 2016-07-07_23:56:08.497700Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-REFL_SERVO_IN1GAIN => 4 2016-07-07_23:56:08.504450Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:IMC-REFL_SERVO_IN2GAIN => -11 2016-07-07_23:56:08.505290Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-MCL_GAIN => 47.8862955593 2016-07-07_23:56:08.717120Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-REFL_SERVO_IN1GAIN => 5 2016-07-07_23:56:08.728430Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:IMC-REFL_SERVO_IN2GAIN => -12 2016-07-07_23:56:08.731150Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-MCL_GAIN => 42.6787058409 2016-07-07_23:56:08.944690Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-REFL_SERVO_IN1GAIN => 6 2016-07-07_23:56:08.957410Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:IMC-REFL_SERVO_IN2GAIN => -13 2016-07-07_23:56:08.957970Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-MCL_GAIN => 38.0374366191 2016-07-07_23:56:09.170800Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-REFL_SERVO_IN1GAIN => 7 2016-07-07_23:56:09.185380Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:IMC-REFL_SERVO_IN2GAIN => -14 2016-07-07_23:56:09.186210Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-MCL_GAIN => 33.9009010709 2016-07-07_23:56:09.401650Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-REFL_SERVO_IN1GAIN => 8 2016-07-07_23:56:09.412860Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:IMC-REFL_SERVO_IN2GAIN => -15 2016-07-07_23:56:09.421730Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-MCL_GAIN => 30.2142098831 2016-07-07_23:56:09.631050Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-REFL_SERVO_IN1GAIN => 9 2016-07-07_23:56:09.644640Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:IMC-REFL_SERVO_IN2GAIN => -16 2016-07-07_23:56:09.647630Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-MCL_GAIN => 26.9284429032 2016-07-07_23:56:09.859820Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-REFL_SERVO_IN1GAIN => 10 2016-07-07_23:56:09.877920Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:IMC-REFL_SERVO_IN2GAIN => -17 2016-07-07_23:56:09.878810Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-MCL_GAIN => 24.0 2016-07-07_23:56:10.097370Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-REFL_SERVO_IN1GAIN => 11 2016-07-07_23:56:10.109310Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:IMC-REFL_SERVO_IN2GAIN => -18 2016-07-07_23:56:10.113780Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-MCL_GAIN => 21.3900225152 2016-07-07_23:56:10.316310Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-REFL_SERVO_IN1GAIN => 12 2016-07-07_23:56:10.330270Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:IMC-REFL_SERVO_IN2GAIN => -19 2016-07-07_23:56:10.332450Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-MCL_GAIN => 19.0638776334 2016-07-07_23:56:10.545870Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-REFL_SERVO_IN1GAIN => 13 2016-07-07_23:56:10.557840Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:IMC-REFL_SERVO_IN2GAIN => -20 2016-07-07_23:56:10.558520Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-MCL_GAIN => 16.9906988252 2016-07-07_23:56:10.772130Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-REFL_SERVO_IN1GAIN => 14 2016-07-07_23:56:10.788000Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:IMC-REFL_SERVO_IN2GAIN => -21 2016-07-07_23:56:10.789250Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-MCL_GAIN => 15.1429762675 2016-07-07_23:56:10.996050Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-REFL_SERVO_IN1GAIN => 15 2016-07-07_23:56:11.006430Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:IMC-REFL_SERVO_IN2GAIN => -22 2016-07-07_23:56:11.008100Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-MCL_GAIN => 13.4961918046 2016-07-07_23:56:11.219970Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-REFL_SERVO_IN1GAIN => 16 2016-07-07_23:56:11.232390Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:IMC-REFL_SERVO_IN2GAIN => -23 2016-07-07_23:56:11.233390Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-MCL_GAIN => 12.0284936071 2016-07-07_23:56:11.435830Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-REFL_SERVO_IN1GAIN => 17 2016-07-07_23:56:11.439620Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:IMC-REFL_SERVO_IN2GAIN => -24 2016-07-07_23:56:11.440410Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-MCL_GAIN => 10.7204062116 2016-07-07_23:56:11.657890Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-REFL_SERVO_IN1GAIN => 18 2016-07-07_23:56:11.672030Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-REFL_SERVO_FASTGAIN => -3 2016-07-07_23:56:11.672760Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-MCL_GAIN => 9.55457209328 2016-07-07_23:56:11.685270Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-REFL_SERVO_IN1GAIN => 19 2016-07-07_23:56:11.698320Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-REFL_SERVO_FASTGAIN => -4 2016-07-07_23:56:11.707280Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-MCL_GAIN => 8.51552134161 2016-07-07_23:56:11.718600Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-REFL_SERVO_IN1GAIN => 20 2016-07-07_23:56:11.729680Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-REFL_SERVO_FASTGAIN => -5 2016-07-07_23:56:11.730240Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-MCL_GAIN => 7.5894663844 2016-07-07_23:56:11.746930Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-REFL_SERVO_IN1GAIN => 21 2016-07-07_23:56:11.767370Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-REFL_SERVO_FASTGAIN => -6 2016-07-07_23:56:11.771140Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-MCL_GAIN => 6.76411903503 2016-07-07_23:56:11.784320Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-REFL_SERVO_IN1GAIN => 22 2016-07-07_23:56:11.785660Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-REFL_SERVO_FASTGAIN => -7 2016-07-07_23:56:11.789670Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-MCL_GAIN => 6.02852743562 2016-07-07_23:56:11.795920Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-REFL_SERVO_IN1GAIN => 23 2016-07-07_23:56:11.807100Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-REFL_SERVO_FASTGAIN => -8 2016-07-07_23:56:11.810750Z ISC_LOCK [ANALOG_CARM.run] ezca: H1:LSC-MCL_GAIN => 5.37293073256 2016-07-07_23:56:11.892520Z ISC_LOCK EDGE: ANALOG_CARM->DRMI_ON_POP 2016-07-07_23:56:11.893250Z ISC_LOCK calculating path: DRMI_ON_POP->ENGAGE_SOFT_LOOPS 2016-07-07_23:56:11.894000Z ISC_LOCK new target: DARM_OFFSET 2016-07-07_23:56:11.894950Z ISC_LOCK executing state: DRMI_ON_POP (425) 2016-07-07_23:56:11.895330Z ISC_LOCK [DRMI_ON_POP.enter] 2016-07-07_23:56:11.904010Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:LSC-PD_DOF_MTRX_SETTING_4_1 => 0.035 2016-07-07_23:56:11.908340Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:LSC-PD_DOF_MTRX_SETTING_3_4 => 0.08 2016-07-07_23:56:11.909190Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:LSC-PD_DOF_MTRX_SETTING_5_3 => 0.08 2016-07-07_23:56:11.910000Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:LSC-PD_DOF_MTRX_SETTING_5_1 => -0.0151 2016-07-07_23:56:11.910500Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:LSC-PD_DOF_MTRX_SETTING_3_20 => 0 2016-07-07_23:56:11.910990Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:LSC-PD_DOF_MTRX_SETTING_4_17 => 0 2016-07-07_23:56:11.911480Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:LSC-PD_DOF_MTRX_SETTING_5_17 => 0 2016-07-07_23:56:11.917630Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:LSC-PD_DOF_MTRX_SETTING_5_19 => 0 2016-07-07_23:56:11.918200Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:LSC-PD_DOF_MTRX_TRAMP => 5 2016-07-07_23:56:12.122270Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:LSC-PD_DOF_MTRX_LOAD_MATRIX => 1 2016-07-07_23:56:12.122660Z ISC_LOCK [DRMI_ON_POP.main] timer['ramp_drmi'] = 6 2016-07-07_23:56:12.131280Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:LSC-MICH_TRIG_THRESH_ON => -100 2016-07-07_23:56:12.131870Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:LSC-MICH_TRIG_THRESH_OFF => -100 2016-07-07_23:56:12.132450Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:LSC-MICH_FM_TRIG_THRESH_ON => -100 2016-07-07_23:56:12.133470Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:LSC-MICH_FM_TRIG_THRESH_OFF => -100 2016-07-07_23:56:12.136960Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:LSC-PRCL_FM_TRIG_THRESH_ON => -100 2016-07-07_23:56:12.137560Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:LSC-PRCL_FM_TRIG_THRESH_OFF => -100 2016-07-07_23:56:12.138100Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:LSC-SRCL_TRIG_THRESH_ON => -100 2016-07-07_23:56:12.138900Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:LSC-SRCL_TRIG_THRESH_OFF => -100 2016-07-07_23:56:12.142360Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:LSC-SRCL_FM_TRIG_THRESH_ON => -100 2016-07-07_23:56:12.146050Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:LSC-SRCL_FM_TRIG_THRESH_OFF => -100 2016-07-07_23:56:12.150410Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:LSC-MCL_TRIG_THRESH_ON => -100 2016-07-07_23:56:12.152560Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:LSC-MCL_TRIG_THRESH_OFF => -100 2016-07-07_23:56:12.254650Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:LSC-TRIG_MTRX_2_2 => 0 2016-07-07_23:56:12.255230Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:LSC-TRIG_MTRX_3_2 => 0 2016-07-07_23:56:12.261690Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:LSC-TRIG_MTRX_4_2 => 0 2016-07-07_23:56:12.370940Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:LSC-TRIG_MTRX_1_17 => 1 2016-07-07_23:56:12.370970Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:LSC-TRIG_MTRX_2_17 => 1 2016-07-07_23:56:12.370980Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:LSC-TRIG_MTRX_3_17 => 1 2016-07-07_23:56:12.370990Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:LSC-TRIG_MTRX_4_17 => 1 2016-07-07_23:56:12.370990Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:LSC-TRIG_MTRX_5_17 => 1 2016-07-07_23:56:12.470690Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:LSC-DARM_TRIG_THRESH_OFF => 100 2016-07-07_23:56:12.471140Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:LSC-DARM_TRIG_THRESH_ON => 101 2016-07-07_23:56:12.471680Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:LSC-MICH_TRIG_THRESH_OFF => 100 2016-07-07_23:56:12.473830Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:LSC-MICH_TRIG_THRESH_ON => 101 2016-07-07_23:56:12.474310Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:LSC-PRCL_TRIG_THRESH_OFF => 100 2016-07-07_23:56:12.474850Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:LSC-PRCL_TRIG_THRESH_ON => 101 2016-07-07_23:56:12.475370Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:LSC-SRCL_TRIG_THRESH_OFF => 100 2016-07-07_23:56:12.475820Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:LSC-SRCL_TRIG_THRESH_ON => 101 2016-07-07_23:56:12.476340Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:LSC-MCL_TRIG_THRESH_OFF => 100 2016-07-07_23:56:12.476860Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:LSC-MCL_TRIG_THRESH_ON => 101 2016-07-07_23:56:12.480740Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:SUS-ITMX_L2_DAMP_MODE1_TRAMP => 10 2016-07-07_23:56:12.481350Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:SUS-ITMX_L2_DAMP_MODE2_TRAMP => 10 2016-07-07_23:56:12.481870Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:SUS-ITMX_L2_DAMP_MODE3_TRAMP => 10 2016-07-07_23:56:12.483340Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:SUS-ITMX_L2_DAMP_MODE4_TRAMP => 10 2016-07-07_23:56:12.483360Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:SUS-ITMX_L2_DAMP_MODE5_TRAMP => 10 2016-07-07_23:56:12.485960Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:SUS-ITMX_L2_DAMP_MODE6_TRAMP => 10 2016-07-07_23:56:12.491730Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:SUS-ITMX_L2_DAMP_MODE7_TRAMP => 10 2016-07-07_23:56:12.499380Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:SUS-ITMX_L2_DAMP_MODE8_TRAMP => 10 2016-07-07_23:56:12.500050Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:SUS-ITMX_L2_DAMP_MODE9_TRAMP => 10 2016-07-07_23:56:12.505560Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:SUS-ITMX_L2_DAMP_MODE10_TRAMP => 10 2016-07-07_23:56:12.506790Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:SUS-ITMX_M0_DARM_DAMP_V_TRAMP => 10 2016-07-07_23:56:12.510780Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:SUS-ITMX_M0_DARM_DAMP_R_TRAMP => 10 2016-07-07_23:56:12.511490Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:SUS-ITMY_L2_DAMP_MODE1_TRAMP => 10 2016-07-07_23:56:12.512040Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:SUS-ITMY_L2_DAMP_MODE2_TRAMP => 10 2016-07-07_23:56:12.514330Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:SUS-ITMY_L2_DAMP_MODE3_TRAMP => 10 2016-07-07_23:56:12.515120Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:SUS-ITMY_L2_DAMP_MODE4_TRAMP => 10 2016-07-07_23:56:12.515880Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:SUS-ITMY_L2_DAMP_MODE5_TRAMP => 10 2016-07-07_23:56:12.516580Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:SUS-ITMY_L2_DAMP_MODE6_TRAMP => 10 2016-07-07_23:56:12.517240Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:SUS-ITMY_L2_DAMP_MODE7_TRAMP => 10 2016-07-07_23:56:12.517720Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:SUS-ITMY_L2_DAMP_MODE8_TRAMP => 10 2016-07-07_23:56:12.518290Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:SUS-ITMY_L2_DAMP_MODE9_TRAMP => 10 2016-07-07_23:56:12.519140Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:SUS-ITMY_L2_DAMP_MODE10_TRAMP => 10 2016-07-07_23:56:12.519940Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:SUS-ITMY_M0_DARM_DAMP_V_TRAMP => 10 2016-07-07_23:56:12.520710Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:SUS-ITMY_M0_DARM_DAMP_R_TRAMP => 10 2016-07-07_23:56:12.522180Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:SUS-ETMX_L2_DAMP_MODE1_TRAMP => 10 2016-07-07_23:56:12.523110Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:SUS-ETMX_L2_DAMP_MODE2_TRAMP => 10 2016-07-07_23:56:12.524840Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:SUS-ETMX_L2_DAMP_MODE3_TRAMP => 10 2016-07-07_23:56:12.529650Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:SUS-ETMX_L2_DAMP_MODE4_TRAMP => 10 2016-07-07_23:56:12.531230Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:SUS-ETMX_L2_DAMP_MODE5_TRAMP => 10 2016-07-07_23:56:12.534320Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:SUS-ETMX_L2_DAMP_MODE6_TRAMP => 10 2016-07-07_23:56:12.537150Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:SUS-ETMX_L2_DAMP_MODE7_TRAMP => 10 2016-07-07_23:56:12.537930Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:SUS-ETMX_L2_DAMP_MODE8_TRAMP => 10 2016-07-07_23:56:12.542740Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:SUS-ETMX_L2_DAMP_MODE9_TRAMP => 10 2016-07-07_23:56:12.544850Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:SUS-ETMX_L2_DAMP_MODE10_TRAMP => 10 2016-07-07_23:56:12.545520Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:SUS-ETMX_M0_DARM_DAMP_V_TRAMP => 10 2016-07-07_23:56:12.551850Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:SUS-ETMX_M0_DARM_DAMP_R_TRAMP => 10 2016-07-07_23:56:12.553940Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:SUS-ETMY_L2_DAMP_MODE1_TRAMP => 10 2016-07-07_23:56:12.554490Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:SUS-ETMY_L2_DAMP_MODE2_TRAMP => 10 2016-07-07_23:56:12.555100Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:SUS-ETMY_L2_DAMP_MODE3_TRAMP => 10 2016-07-07_23:56:12.558350Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:SUS-ETMY_L2_DAMP_MODE4_TRAMP => 10 2016-07-07_23:56:12.559760Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:SUS-ETMY_L2_DAMP_MODE5_TRAMP => 10 2016-07-07_23:56:12.560670Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:SUS-ETMY_L2_DAMP_MODE6_TRAMP => 10 2016-07-07_23:56:12.562370Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:SUS-ETMY_L2_DAMP_MODE7_TRAMP => 10 2016-07-07_23:56:12.562830Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:SUS-ETMY_L2_DAMP_MODE8_TRAMP => 10 2016-07-07_23:56:12.563360Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:SUS-ETMY_L2_DAMP_MODE9_TRAMP => 10 2016-07-07_23:56:12.563970Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:SUS-ETMY_L2_DAMP_MODE10_TRAMP => 10 2016-07-07_23:56:12.564500Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:SUS-ETMY_M0_DARM_DAMP_V_TRAMP => 10 2016-07-07_23:56:12.565030Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:SUS-ETMY_M0_DARM_DAMP_R_TRAMP => 10 2016-07-07_23:56:12.565650Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:SUS-ETMY_M0_DARM_DAMP_V_GAIN => 0.1 2016-07-07_23:56:12.566300Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:SUS-ITMX_M0_DARM_DAMP_V_GAIN => 0.1 2016-07-07_23:56:12.568940Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:SUS-ITMY_M0_DARM_DAMP_V_GAIN => 0.1 2016-07-07_23:56:12.570790Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:ASC-X_TR_A_WHITEN_GAIN => 3 2016-07-07_23:56:12.573570Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:ASC-X_TR_A_NSUM_GAIN => 5.63 2016-07-07_23:56:12.586480Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:ASC-X_TR_B_WHITEN_GAIN => 3 2016-07-07_23:56:12.588000Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:ASC-X_TR_B_NSUM_GAIN => 5.63 2016-07-07_23:56:12.590030Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:ASC-Y_TR_A_WHITEN_GAIN => 3 2016-07-07_23:56:12.592630Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:ASC-Y_TR_A_NSUM_GAIN => 5.63 2016-07-07_23:56:12.606680Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:ASC-Y_TR_B_WHITEN_GAIN => 3 2016-07-07_23:56:12.610130Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:ASC-Y_TR_B_NSUM_GAIN => 5.63 2016-07-07_23:56:12.624330Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:ASC-POP_A_WHITEN_GAIN => 6 2016-07-07_23:56:12.628830Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:ASC-POP_B_WHITEN_GAIN => 6 2016-07-07_23:56:12.629770Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:LSC-MICH2_SW1 => 64 2016-07-07_23:56:12.882940Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:LSC-MICH2 => OFF: FM2 2016-07-07_23:56:12.886450Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:LSC-MICH2_SW1 => 256 2016-07-07_23:56:13.145820Z ISC_LOCK [DRMI_ON_POP.main] ezca: H1:LSC-MICH2 => ON: FM3 2016-07-07_23:56:13.159850Z ISC_LOCK [DRMI_ON_POP.run] USERMSG 1: Input matrix not ready. 2016-07-07_23:56:17.184780Z ISC_LOCK [DRMI_ON_POP.run] ezca: H1:LSC-DARM1_TRAMP => 5 2016-07-07_23:56:17.290800Z ISC_LOCK [DRMI_ON_POP.run] ezca: H1:LSC-DARM1_GAIN => 840 2016-07-07_23:56:17.291270Z ISC_LOCK [DRMI_ON_POP.run] timer['pause'] = 5.0 2016-07-07_23:56:18.124530Z ISC_LOCK [DRMI_ON_POP.run] timer['ramp_drmi'] done 2016-07-07_23:56:22.291610Z ISC_LOCK [DRMI_ON_POP.run] timer['pause'] done 2016-07-07_23:56:22.449970Z ISC_LOCK EDGE: DRMI_ON_POP->DARM_OFFSET 2016-07-07_23:56:22.450730Z ISC_LOCK calculating path: DARM_OFFSET->ENGAGE_SOFT_LOOPS 2016-07-07_23:56:22.451280Z ISC_LOCK new target: ENGAGE_REFL_POP_WFS 2016-07-07_23:56:22.451980Z ISC_LOCK executing state: DARM_OFFSET (427) 2016-07-07_23:56:22.452140Z ISC_LOCK [DARM_OFFSET.enter] 2016-07-07_23:56:22.711270Z ISC_LOCK [DARM_OFFSET.main] ezca: H1:LSC-DARM1 => ON: OFFSET 2016-07-07_23:56:22.711930Z ISC_LOCK [DARM_OFFSET.main] ezca: H1:LSC-DARM1_OFFSET => 2e-05 2016-07-07_23:56:22.712260Z ISC_LOCK [DARM_OFFSET.main] ezca: H1:OMC-READOUT_X0_OFFSET => 28 2016-07-07_23:56:22.712660Z ISC_LOCK [DARM_OFFSET.main] ezca: H1:LSC-DARM1_OFFSET => 3e-05 2016-07-07_23:56:22.713020Z ISC_LOCK [DARM_OFFSET.main] ezca: H1:OMC-READOUT_X0_OFFSET => 42 2016-07-07_23:56:22.773780Z ISC_LOCK [DARM_OFFSET.run] ezca: H1:GRD-OMC_LOCK_REQUEST => READY_FOR_HANDOFF 2016-07-07_23:56:22.887500Z ISC_LOCK EDGE: DARM_OFFSET->ENGAGE_REFL_POP_WFS 2016-07-07_23:56:22.888090Z ISC_LOCK calculating path: ENGAGE_REFL_POP_WFS->ENGAGE_SOFT_LOOPS 2016-07-07_23:56:22.889760Z ISC_LOCK new target: ENGAGE_SRC_ASC 2016-07-07_23:56:22.889900Z ISC_LOCK executing state: ENGAGE_REFL_POP_WFS (430) 2016-07-07_23:56:22.890040Z ISC_LOCK [ENGAGE_REFL_POP_WFS.enter] 2016-07-07_23:56:23.154000Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:SUS-ETMX_L2_LOCK_P => ON: FM2 2016-07-07_23:56:23.407420Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:SUS-ETMX_L2_LOCK_Y => ON: FM2 2016-07-07_23:56:23.659860Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:SUS-ETMY_L2_LOCK_P => ON: FM2 2016-07-07_23:56:23.914980Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:SUS-ETMY_L2_LOCK_Y => ON: FM2 2016-07-07_23:56:24.166610Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:SUS-ITMX_L2_LOCK_P => ON: FM2 2016-07-07_23:56:24.425930Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:SUS-ITMX_L2_LOCK_Y => ON: FM2 2016-07-07_23:56:24.679140Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:SUS-ITMY_L2_LOCK_P => ON: FM2 2016-07-07_23:56:24.932010Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:SUS-ITMY_L2_LOCK_Y => ON: FM2 2016-07-07_23:56:24.933040Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:ASC-INMATRIX_P_1_13 => -0.4 2016-07-07_23:56:24.933520Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:ASC-INMATRIX_P_1_15 => -0.4 2016-07-07_23:56:24.934220Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:ASC-INMATRIX_Y_1_13 => -0.4 2016-07-07_23:56:24.934800Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:ASC-INMATRIX_Y_1_15 => -0.2 2016-07-07_23:56:24.935490Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:ASC-INMATRIX_P_4_9 => 0 2016-07-07_23:56:24.936290Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:ASC-INMATRIX_P_4_13 => 0 2016-07-07_23:56:24.936800Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:ASC-INMATRIX_P_4_29 => -0.05 2016-07-07_23:56:24.937150Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:ASC-INMATRIX_Y_4_9 => 0 2016-07-07_23:56:24.937710Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:ASC-INMATRIX_Y_4_13 => 0 2016-07-07_23:56:24.942720Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:ASC-INMATRIX_Y_4_29 => 0.1 2016-07-07_23:56:24.945840Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:ASC-INMATRIX_P_10_9 => 1 2016-07-07_23:56:24.950240Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:ASC-INMATRIX_P_10_13 => 0.3 2016-07-07_23:56:24.952270Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:ASC-INMATRIX_P_10_15 => 1 2016-07-07_23:56:24.952750Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:ASC-INMATRIX_Y_10_9 => 1 2016-07-07_23:56:24.961250Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:ASC-INMATRIX_Y_10_13 => 0.2 2016-07-07_23:56:24.965210Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:ASC-INMATRIX_Y_10_15 => 1.3 2016-07-07_23:56:24.966140Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:ASC-INMATRIX_P_9_23 => -1.1142 2016-07-07_23:56:24.966760Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:ASC-INMATRIX_P_9_24 => 0.6858 2016-07-07_23:56:24.967250Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:ASC-INMATRIX_P_9_25 => 0.355 2016-07-07_23:56:24.967720Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:ASC-INMATRIX_P_9_26 => -0.200555555556 2016-07-07_23:56:24.968200Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:ASC-INMATRIX_P_11_23 => -0.619 2016-07-07_23:56:24.970730Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:ASC-INMATRIX_P_11_24 => 0.381 2016-07-07_23:56:24.970750Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:ASC-INMATRIX_P_11_25 => -0.639 2016-07-07_23:56:24.970760Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:ASC-INMATRIX_P_11_26 => 0.361 2016-07-07_23:56:24.973560Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:ASC-INMATRIX_Y_9_23 => 0.684 2016-07-07_23:56:24.973920Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:ASC-INMATRIX_Y_9_24 => -0.316 2016-07-07_23:56:24.974480Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:ASC-INMATRIX_Y_9_25 => 0.681 2016-07-07_23:56:24.977780Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:ASC-INMATRIX_Y_9_26 => -0.319 2016-07-07_23:56:24.978380Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:ASC-INMATRIX_Y_11_23 => 0.684 2016-07-07_23:56:24.978890Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:ASC-INMATRIX_Y_11_24 => -0.316 2016-07-07_23:56:24.979390Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:ASC-INMATRIX_Y_11_25 => -0.681 2016-07-07_23:56:24.984840Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:ASC-INMATRIX_Y_11_26 => 0.319 2016-07-07_23:56:25.018900Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:ASC-CHARD_P_SW1S => 4 2016-07-07_23:56:25.275540Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:ASC-CHARD_P => ONLY ON: INPUT, FM9, FM10, OUTPUT, DECIMATION 2016-07-07_23:56:25.280290Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:ASC-CHARD_Y_SW1S => 4 2016-07-07_23:56:25.537590Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:ASC-CHARD_Y => ONLY ON: INPUT, FM7, OUTPUT, DECIMATION 2016-07-07_23:56:25.538560Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:ASC-PRC2_P_SW1 => 16 2016-07-07_23:56:25.792420Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:ASC-PRC2_P => ON: FM1 2016-07-07_23:56:25.796450Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:ASC-PRC2_Y_SW1S => 1360 2016-07-07_23:56:25.922730Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:ASC-PRC2_Y_SW2S => 1540 2016-07-07_23:56:26.048130Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:ASC-PRC2_Y => ONLY ON: FM1, FM2, FM3, FM4, FM8, OUTPUT, DECIMATION 2016-07-07_23:56:27.052520Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:ASC-CHARD_P_TRAMP => 30 2016-07-07_23:56:27.053700Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:ASC-CHARD_Y_TRAMP => 30 2016-07-07_23:56:27.187650Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:ASC-SRC2_P_SW2 => 64 2016-07-07_23:56:27.313090Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:ASC-SRC2_P => OFF: FM10 2016-07-07_23:56:27.443450Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:ASC-SRC2_Y_SW2 => 64 2016-07-07_23:56:27.568880Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:ASC-SRC2_Y => OFF: FM10 2016-07-07_23:56:27.670300Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:ASC-CHARD_P_GAIN => -0.03 2016-07-07_23:56:27.671140Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:ASC-CHARD_Y_GAIN => -0.03 2016-07-07_23:56:27.799070Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:SUS-PR2_M3_ISCINF_P_SW2 => 2048 2016-07-07_23:56:27.924510Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:SUS-PR2_M3_ISCINF_P => ON: HOLD 2016-07-07_23:56:28.053710Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:SUS-PR2_M3_ISCINF_Y_SW2 => 2048 2016-07-07_23:56:28.179120Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:SUS-PR2_M3_ISCINF_Y => ON: HOLD 2016-07-07_23:56:28.280090Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:ASC-PRC2_P_RSET => 2 2016-07-07_23:56:28.285650Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:ASC-PRC2_Y_RSET => 2 2016-07-07_23:56:28.386920Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:ASC-OUTMATRIX_P_2_4 => 0 2016-07-07_23:56:28.389550Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:ASC-OUTMATRIX_Y_2_4 => 0 2016-07-07_23:56:28.391780Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:ASC-OUTMATRIX_P_3_4 => 1 2016-07-07_23:56:28.394530Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:ASC-OUTMATRIX_Y_3_4 => -1 2016-07-07_23:56:28.396160Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:ASC-PRC2_P_GAIN => -3 2016-07-07_23:56:28.396990Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:ASC-PRC2_Y_GAIN => -3 2016-07-07_23:56:28.403810Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:SUS-PR3_M1_LOCK_P_SW1 => 4 2016-07-07_23:56:28.659270Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:SUS-PR3_M1_LOCK_P => ON: INPUT 2016-07-07_23:56:28.660290Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:SUS-PR3_M1_LOCK_Y_SW1 => 4 2016-07-07_23:56:28.911670Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:SUS-PR3_M1_LOCK_Y => ON: INPUT 2016-07-07_23:56:28.914590Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:ASC-CHARD_P_TRAMP => 15 2016-07-07_23:56:28.915240Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] ezca: H1:ASC-CHARD_Y_TRAMP => 15 2016-07-07_23:56:28.915570Z ISC_LOCK [ENGAGE_REFL_POP_WFS.main] timer['pause'] = 15.0 2016-07-07_23:56:28.925110Z ISC_LOCK [ENGAGE_REFL_POP_WFS.run] MC not locked 2016-07-07_23:56:28.984990Z ISC_LOCK state returned jump target: LOCKLOSS 2016-07-07_23:56:28.985090Z ISC_LOCK [ENGAGE_REFL_POP_WFS.exit]