############################################################ ############################################################ ### NEW CALIBRATION EPICS "WRITE" MATLAB LOG ### ### 21-Nov-2016 14:03:46 ### ############################################################ ############################################################ ## EXEC PARAMETERS: # # DARM parameter files: # IFO indep: /ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/ER10/Common/params/IFOindepParams.conf.m # IFO dep: /ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/ER10/H1/params/H1params.conf.m # Meas params: /ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/ER10/H1/params/2016-11-12/H1params_2016-11-12.conf.m # # Option "WRITE INTO EPICS CHANNELS" was set to "ON". ############################################################ ### MODEL VALUES FOR CAL LINE at f_tst = 35.9 Hz ### ############################################################ Re{ C_0(35.9) } = 1.08139e+06 Im{ C_0(35.9) } = -132723 Re{ C_{res}(35.9) } = 1.14133e+06 Im{ C_{res}(35.9) } = -31865.6 Re{ D_0(35.9) } = 1.86562e+10 Im{ D_0(35.9) } = 1.96528e+10 Re{ A_0^{tst}(35.9) } = -1.5464e-17 Im{ A_0^{tst}(35.9) } = -4.6291e-17 Re{ A_0^{pum}(35.9) } = -1.70829e-17 Im{ A_0^{pum}(35.9) } = 4.94952e-17 Re{ A_0^{uim}(35.9) } = -2.07291e-20 Im{ A_0^{uim}(35.9) } = -6.06949e-21 Re{ A_0^{top}(35.9) } = 0 Im{ A_0^{top}(35.9) } = 0 Re{ G_0(35.9) } = -1.76319 Im{ G_0(35.9) } = -0.972111 Re{ A_0^{p/u}(35.9) } = -1.71036e-17 Im{ A_0^{p/u}(35.9) } = 4.94891e-17 CALCULATED VALUES FOR CAL LINE at f_tst = 35.9 Hz: | A_0^{tst}(35.9) |^2 = 2.382e-33 Re{ - 1 / A_0^{tst}(35.9) } = 6.49203e+15 Im{ - 1 / A_0^{tst}(35.9) } = -1.94337e+16 Re{ (1 + G_0(35.9)) / C_0(35.9) } = -5.86586e-07 Im{ (1 + G_0(35.9)) / C_0(35.9) } = -9.70943e-07 ############################################################ ### MODEL VALUES FOR CAL LINE at f_pcal = 36.7 Hz ### ############################################################ Re{ C_0(36.7) } = 1.08261e+06 Im{ C_0(36.7) } = -136265 Re{ C_{res}(36.7) } = 1.14131e+06 Im{ C_{res}(36.7) } = -32575.6 Re{ D_0(36.7) } = 1.88422e+10 Im{ D_0(36.7) } = 2.03364e+10 Re{ A_0^{tst}(36.7) } = -4.86678e-17 Im{ A_0^{tst}(36.7) } = -3.49993e-17 Re{ A_0^{pum}(36.7) } = -1.5257e-17 Im{ A_0^{pum}(36.7) } = 4.70899e-17 Re{ A_0^{uim}(36.7) } = -1.82608e-20 Im{ A_0^{uim}(36.7) } = -5.01365e-21 Re{ A_0^{top}(36.7) } = 0 Im{ A_0^{top}(36.7) } = 0 Re{ G_0(36.7) } = -1.71661 Im{ G_0(36.7) } = -0.963602 Re{ A_0^{p/u}(36.7) } = -1.52753e-17 Im{ A_0^{p/u}(36.7) } = 4.70849e-17 CALCULATED VALUES FOR CAL LINE at f_pcal = 36.7 Hz: | A_0^{tst}(36.7) |^2 = 3.59351e-33 Re{ - 1 / A_0^{tst}(36.7) } = 1.35433e+16 Im{ - 1 / A_0^{tst}(36.7) } = -9.73959e+15 Re{ (1 + G_0(36.7)) / C_0(36.7) } = -5.41319e-07 Im{ (1 + G_0(36.7)) / C_0(36.7) } = -9.58204e-07 ############################################################ ### MODEL VALUES FOR CAL LINE at f_ctrl = 37.3 Hz ### ############################################################ Re{ C_0(37.3) } = 1.08345e+06 Im{ C_0(37.3) } = -138911 Re{ C_{res}(37.3) } = 1.14129e+06 Im{ C_{res}(37.3) } = -33108 Re{ D_0(37.3) } = 1.89816e+10 Im{ D_0(37.3) } = 2.08455e+10 Re{ A_0^{tst}(37.3) } = -4.77471e-17 Im{ A_0^{tst}(37.3) } = -3.36371e-17 Re{ A_0^{pum}(37.3) } = -1.39998e-17 Im{ A_0^{pum}(37.3) } = 4.53793e-17 Re{ A_0^{uim}(37.3) } = -1.66313e-20 Im{ A_0^{uim}(37.3) } = -4.34743e-21 Re{ A_0^{top}(37.3) } = 0 Im{ A_0^{top}(37.3) } = 0 Re{ G_0(37.3) } = -1.68319 Im{ G_0(37.3) } = -0.956687 Re{ 1 / A_0^{pu}(37.3) } = -6.21475e+15 Im{ 1 / A_0^{pu}(37.3) } = -2.01189e+16 Re{ A_0^{p/u}(37.3) } = -1.40164e-17 Im{ A_0^{p/u}(37.3) } = 4.53749e-17 CALCULATED VALUES FOR CAL LINE at f_ctrl = 37.3 Hz: | A_0^{tst}(37.3) |^2 = 3.41124e-33 Re{ - 1 / A_0^{tst}(37.3) } = 1.3997e+16 Im{ - 1 / A_0^{tst}(37.3) } = -9.86068e+15 Re{ (1 + G_0(37.3)) / C_0(37.3) } = -5.08993e-07 Im{ (1 + G_0(37.3)) / C_0(37.3) } = -9.48262e-07 ############################################################ ### MODEL VALUES FOR CAL LINE at f_pcal2 = 331.9 Hz ### ############################################################ f_pcal2 = 331.9 Hz Re{ C_0(331.9) } = 431031 Im{ C_0(331.9) } = -703059 Re{ C_{res}(331.9) } = 1.10433e+06 Im{ C_{res}(331.9) } = -291688 Re{ D_0(331.9) } = 3.13584e+09 Im{ D_0(331.9) } = 9.70629e+08 Re{ A_0^{tst}(331.9) } = -7.30032e-19 Im{ A_0^{tst}(331.9) } = 5.98373e-19 Re{ A_0^{pum}(331.9) } = -1.57606e-19 Im{ A_0^{pum}(331.9) } = -3.83957e-20 Re{ A_0^{uim}(331.9) } = 1.2656e-25 Im{ A_0^{uim}(331.9) } = 6.08833e-26 Re{ A_0^{top}(331.9) } = 0 Im{ A_0^{top}(331.9) } = 0 Re{ G_0(331.9) } = -0.00080521 Im{ G_0(331.9) } = 0.00272462 Re{ A_0^{p/u}(331.9) } = -1.57606e-19 Im{ A_0^{p/u}(331.9) } = -3.83956e-20 CALCULATED VALUES FOR CAL LINE at f_pcal2 = 331.9 Hz: | A_0^{tst}(331.9) |^2 = 8.90998e-37 Re{ - 1 / A_0^{tst}(331.9) } = 8.19342e+17 Im{ - 1 / A_0^{tst}(331.9) } = 6.71577e+17 Re{ (1 + G_0(331.9)) / C_0(331.9) } = 6.30468e-07 Im{ (1 + G_0(331.9)) / C_0(331.9) } = 1.03468e-06 ############################################################ ### MODEL VALUES FROM COMBINATION OF CAL LINES ### ############################################################ Re{ R_tst } = Re{ (C_0(f_pcal) / (1 + G_0(f_pcal))) * (C_0(f_tst) / (1 + G_0(f_tst)))^{-1} } = 1.03031 Im{ R_tst } = Im{ (C_0(f_pcal) / (1 + G_0(f_pcal))) * (C_0(f_tst) / (1 + G_0(f_tst)))^{-1} } = -0.0301184 Re{ (- 1 / A_0^tst(f_tst)) * (C_0(f_pcal) / (1 + G_0(f_pcal))) * (C_0(f_tst) / (1 + G_0(f_tst)))^{-1} } = -6.10348e+15 Im{ (- 1 / A_0^tst(f_tst)) * (C_0(f_pcal) / (1 + G_0(f_pcal))) * (C_0(f_tst) / (1 + G_0(f_tst)))^{-1} } = 2.02183e+16 Re{ R_ctrl } = Re{ (C_0(f_pcal) / (1 + G_0(f_pcal))) * (C_0(f_ctrl) / (1 + G_0(f_ctrl)))^{-1} } = 0.977285 Im{ R_ctrl } = Im{ (C_0(f_pcal) / (1 + G_0(f_pcal))) * (C_0(f_ctrl) / (1 + G_0(f_ctrl)))^{-1} } = 0.0351133 ############################################################ ### WRITING INTO EPICS ### ############################################################ Old : H1:CAL-CS_TDEP_ESD_LINE1_REF_C_REAL 1.04861e+06 New : H1:CAL-CS_TDEP_ESD_LINE1_REF_C_REAL 1.08139e+06 Old : H1:CAL-CS_TDEP_ESD_LINE1_REF_C_IMAG -168062 New : H1:CAL-CS_TDEP_ESD_LINE1_REF_C_IMAG -132723 Old : H1:CAL-CS_TDEP_ESD_LINE1_REF_C_NOCAVPOLE_REAL 1.14739e+06 New : H1:CAL-CS_TDEP_ESD_LINE1_REF_C_NOCAVPOLE_REAL 1.14133e+06 Old : H1:CAL-CS_TDEP_ESD_LINE1_REF_C_NOCAVPOLE_IMAG -54987.1 New : H1:CAL-CS_TDEP_ESD_LINE1_REF_C_NOCAVPOLE_IMAG -31865.6 Old : H1:CAL-CS_TDEP_ESD_LINE1_REF_D_REAL 1.20536e+10 New : H1:CAL-CS_TDEP_ESD_LINE1_REF_D_REAL 1.86562e+10 Old : H1:CAL-CS_TDEP_ESD_LINE1_REF_D_IMAG 2.46182e+10 New : H1:CAL-CS_TDEP_ESD_LINE1_REF_D_IMAG 1.96528e+10 Channel connect timed out: 'H1:CAL-CS_TDEP_ESD_LINE1_REF_A_TST_REAL' not found. Channel connect timed out: 'H1:CAL-CS_TDEP_ESD_LINE1_REF_A_TST_IMAG' not found. Channel connect timed out: 'H1:CAL-CS_TDEP_ESD_LINE1_REF_A_PUM_REAL' not found. Channel connect timed out: 'H1:CAL-CS_TDEP_ESD_LINE1_REF_A_PUM_IMAG' not found. Channel connect timed out: 'H1:CAL-CS_TDEP_ESD_LINE1_REF_A_UIM_REAL' not found. Channel connect timed out: 'H1:CAL-CS_TDEP_ESD_LINE1_REF_A_UIM_IMAG' not found. Channel connect timed out: 'H1:CAL-CS_TDEP_ESD_LINE1_REF_A_TOP_REAL' not found. Channel connect timed out: 'H1:CAL-CS_TDEP_ESD_LINE1_REF_A_TOP_IMAG' not found. Old : H1:CAL-CS_TDEP_ESD_LINE1_REF_OLG_REAL -1.39537 New : H1:CAL-CS_TDEP_ESD_LINE1_REF_OLG_REAL -1.76319 Old : H1:CAL-CS_TDEP_ESD_LINE1_REF_OLG_IMAG -1.34476 New : H1:CAL-CS_TDEP_ESD_LINE1_REF_OLG_IMAG -0.972111 Channel connect timed out: 'H1:CAL-CS_TDEP_ESD_LINE1_REF_A_USUM_REAL' not found. Channel connect timed out: 'H1:CAL-CS_TDEP_ESD_LINE1_REF_A_USUM_IMAG' not found. Old : H1:CAL-CS_TDEP_PCALY_LINE1_REF_C_REAL 1.05088e+06 New : H1:CAL-CS_TDEP_PCALY_LINE1_REF_C_REAL 1.08261e+06 Old : H1:CAL-CS_TDEP_PCALY_LINE1_REF_C_IMAG -172223 New : H1:CAL-CS_TDEP_PCALY_LINE1_REF_C_IMAG -136265 Old : H1:CAL-CS_TDEP_PCALY_LINE1_REF_C_NOCAVPOLE_REAL 1.14733e+06 New : H1:CAL-CS_TDEP_PCALY_LINE1_REF_C_NOCAVPOLE_REAL 1.14131e+06 Old : H1:CAL-CS_TDEP_PCALY_LINE1_REF_C_NOCAVPOLE_IMAG -56211.5 New : H1:CAL-CS_TDEP_PCALY_LINE1_REF_C_NOCAVPOLE_IMAG -32575.6 Old : H1:CAL-CS_TDEP_PCALY_LINE1_REF_D_REAL 1.21972e+10 New : H1:CAL-CS_TDEP_PCALY_LINE1_REF_D_REAL 1.88422e+10 Old : H1:CAL-CS_TDEP_PCALY_LINE1_REF_D_IMAG 2.52386e+10 New : H1:CAL-CS_TDEP_PCALY_LINE1_REF_D_IMAG 2.03364e+10 Channel connect timed out: 'H1:CAL-CS_TDEP_PCALY_LINE1_REF_A_TST_REAL' not found. Channel connect timed out: 'H1:CAL-CS_TDEP_PCALY_LINE1_REF_A_TST_IMAG' not found. Channel connect timed out: 'H1:CAL-CS_TDEP_PCALY_LINE1_REF_A_PUM_REAL' not found. Channel connect timed out: 'H1:CAL-CS_TDEP_PCALY_LINE1_REF_A_PUM_IMAG' not found. Channel connect timed out: 'H1:CAL-CS_TDEP_PCALY_LINE1_REF_A_UIM_REAL' not found. Channel connect timed out: 'H1:CAL-CS_TDEP_PCALY_LINE1_REF_A_UIM_IMAG' not found. Channel connect timed out: 'H1:CAL-CS_TDEP_PCALY_LINE1_REF_A_TOP_REAL' not found. Channel connect timed out: 'H1:CAL-CS_TDEP_PCALY_LINE1_REF_A_TOP_IMAG' not found. Old : H1:CAL-CS_TDEP_PCALY_LINE1_REF_OLG_REAL -1.3638 New : H1:CAL-CS_TDEP_PCALY_LINE1_REF_OLG_REAL -1.71661 Old : H1:CAL-CS_TDEP_PCALY_LINE1_REF_OLG_IMAG -1.31599 New : H1:CAL-CS_TDEP_PCALY_LINE1_REF_OLG_IMAG -0.963602 Channel connect timed out: 'H1:CAL-CS_TDEP_PCALY_LINE1_REF_A_USUM_REAL' not found. Channel connect timed out: 'H1:CAL-CS_TDEP_PCALY_LINE1_REF_A_USUM_IMAG' not found. Channel connect timed out: 'H1:CAL-CS_TDEP_DARM_LINE1_REF_C_REAL' not found. Channel connect timed out: 'H1:CAL-CS_TDEP_DARM_LINE1_REF_C_IMAG' not found. Channel connect timed out: 'H1:CAL-CS_TDEP_DARM_LINE1_REF_C_NOCAVPOLE_REAL' not found. Channel connect timed out: 'H1:CAL-CS_TDEP_DARM_LINE1_REF_C_NOCAVPOLE_IMAG' not found. Channel connect timed out: 'H1:CAL-CS_TDEP_DARM_LINE1_REF_D_REAL' not found. Channel connect timed out: 'H1:CAL-CS_TDEP_DARM_LINE1_REF_D_IMAG' not found. Old : H1:CAL-CS_TDEP_DARM_LINE1_REF_A_TST_REAL -4.53245e-17 New : H1:CAL-CS_TDEP_DARM_LINE1_REF_A_TST_REAL -4.77471e-17 Old : H1:CAL-CS_TDEP_DARM_LINE1_REF_A_TST_IMAG -3.32955e-17 New : H1:CAL-CS_TDEP_DARM_LINE1_REF_A_TST_IMAG -3.36371e-17 Channel connect timed out: 'H1:CAL-CS_TDEP_DARM_LINE1_REF_A_PUM_REAL' not found. Channel connect timed out: 'H1:CAL-CS_TDEP_DARM_LINE1_REF_A_PUM_IMAG' not found. Channel connect timed out: 'H1:CAL-CS_TDEP_DARM_LINE1_REF_A_UIM_REAL' not found. Channel connect timed out: 'H1:CAL-CS_TDEP_DARM_LINE1_REF_A_UIM_IMAG' not found. Channel connect timed out: 'H1:CAL-CS_TDEP_DARM_LINE1_REF_A_TOP_REAL' not found. Channel connect timed out: 'H1:CAL-CS_TDEP_DARM_LINE1_REF_A_TOP_IMAG' not found. Channel connect timed out: 'H1:CAL-CS_TDEP_DARM_LINE1_REF_OLG_REAL' not found. Channel connect timed out: 'H1:CAL-CS_TDEP_DARM_LINE1_REF_OLG_IMAG' not found. Old : H1:CAL-CS_TDEP_DARM_LINE1_REF_A_USUM_INV_REAL -6.63233e+15 New : H1:CAL-CS_TDEP_DARM_LINE1_REF_A_USUM_INV_REAL -6.21475e+15 Old : H1:CAL-CS_TDEP_DARM_LINE1_REF_A_USUM_INV_IMAG -2.00511e+16 New : H1:CAL-CS_TDEP_DARM_LINE1_REF_A_USUM_INV_IMAG -2.01189e+16 Old : H1:CAL-CS_TDEP_DARM_LINE1_REF_A_USUM_REAL -1.48695e-17 New : H1:CAL-CS_TDEP_DARM_LINE1_REF_A_USUM_REAL -1.40164e-17 Old : H1:CAL-CS_TDEP_DARM_LINE1_REF_A_USUM_IMAG 4.49541e-17 New : H1:CAL-CS_TDEP_DARM_LINE1_REF_A_USUM_IMAG 4.53749e-17 Old : H1:CAL-CS_TDEP_CAVITY_POLE_PCAL_FREQ 331.9 New : H1:CAL-CS_TDEP_CAVITY_POLE_PCAL_FREQ 331.9 Old : H1:CAL-CS_TDEP_PCALY_LINE2_REF_C_REAL 257063 New : H1:CAL-CS_TDEP_PCALY_LINE2_REF_C_REAL 431031 Old : H1:CAL-CS_TDEP_PCALY_LINE2_REF_C_IMAG -757012 New : H1:CAL-CS_TDEP_PCALY_LINE2_REF_C_IMAG -703059 Old : H1:CAL-CS_TDEP_PCALY_LINE2_REF_C_NOCAVPOLE_REAL 1.03826e+06 New : H1:CAL-CS_TDEP_PCALY_LINE2_REF_C_NOCAVPOLE_REAL 1.10433e+06 Old : H1:CAL-CS_TDEP_PCALY_LINE2_REF_C_NOCAVPOLE_IMAG -492477 New : H1:CAL-CS_TDEP_PCALY_LINE2_REF_C_NOCAVPOLE_IMAG -291688 Old : H1:CAL-CS_TDEP_PCALY_LINE2_REF_D_REAL 3.10366e+09 New : H1:CAL-CS_TDEP_PCALY_LINE2_REF_D_REAL 3.13584e+09 Old : H1:CAL-CS_TDEP_PCALY_LINE2_REF_D_IMAG 1.0705e+09 New : H1:CAL-CS_TDEP_PCALY_LINE2_REF_D_IMAG 9.70629e+08 Old : H1:CAL-CS_TDEP_PCALY_LINE2_REF_A_TST_REAL -7.93231e-19 New : H1:CAL-CS_TDEP_PCALY_LINE2_REF_A_TST_REAL -7.30032e-19 Old : H1:CAL-CS_TDEP_PCALY_LINE2_REF_A_TST_IMAG 4.43755e-19 New : H1:CAL-CS_TDEP_PCALY_LINE2_REF_A_TST_IMAG 5.98373e-19 Channel connect timed out: 'H1:CAL-CS_TDEP_PCALY_LINE2_REF_A_PUM_REAL' not found. Channel connect timed out: 'H1:CAL-CS_TDEP_PCALY_LINE2_REF_A_PUM_IMAG' not found. Channel connect timed out: 'H1:CAL-CS_TDEP_PCALY_LINE2_REF_A_UIM_REAL' not found. Channel connect timed out: 'H1:CAL-CS_TDEP_PCALY_LINE2_REF_A_UIM_IMAG' not found. Channel connect timed out: 'H1:CAL-CS_TDEP_PCALY_LINE2_REF_A_TOP_REAL' not found. Channel connect timed out: 'H1:CAL-CS_TDEP_PCALY_LINE2_REF_A_TOP_IMAG' not found. Old : H1:CAL-CS_TDEP_PCALY_LINE2_REF_OLG_REAL -0.000728601 New : H1:CAL-CS_TDEP_PCALY_LINE2_REF_OLG_REAL -0.00080521 Old : H1:CAL-CS_TDEP_PCALY_LINE2_REF_OLG_IMAG 0.00256102 New : H1:CAL-CS_TDEP_PCALY_LINE2_REF_OLG_IMAG 0.00272462 Old : H1:CAL-CS_TDEP_PCALY_LINE2_REF_A_USUM_REAL -1.47975e-19 New : H1:CAL-CS_TDEP_PCALY_LINE2_REF_A_USUM_REAL -1.57606e-19 Old : H1:CAL-CS_TDEP_PCALY_LINE2_REF_A_USUM_IMAG -6.52885e-20 New : H1:CAL-CS_TDEP_PCALY_LINE2_REF_A_USUM_IMAG -3.83956e-20 Old : H1:CAL-CS_TDEP_REF_INVA_CLGRATIO_TST_REAL -6.12808e+15 New : H1:CAL-CS_TDEP_REF_INVA_CLGRATIO_TST_REAL -6.10348e+15 Old : H1:CAL-CS_TDEP_REF_INVA_CLGRATIO_TST_IMAG 2.103e+16 New : H1:CAL-CS_TDEP_REF_INVA_CLGRATIO_TST_IMAG 2.02183e+16 Old : H1:CAL-CS_TDEP_REF_CLGRATIO_CTRL_REAL 0.978425 New : H1:CAL-CS_TDEP_REF_CLGRATIO_CTRL_REAL 0.977285 Old : H1:CAL-CS_TDEP_REF_CLGRATIO_CTRL_IMAG 0.0284443 New : H1:CAL-CS_TDEP_REF_CLGRATIO_CTRL_IMAG 0.0351133 ############################################################ ### END OF LOG (START TIME: 21-Nov-2016 14:03:46) ### ############################################################