2016-12-01T16:48:20.36218 TCS_ITMX_CO2 Guardian v1.0.3 2016-12-01T16:48:20.36230 TCS_ITMX_CO2 EZCA v1.0.0 2016-12-01T16:48:20.37132 cas warning: Configured TCP port was unavailable. 2016-12-01T16:48:20.37135 cas warning: Using dynamically assigned TCP port 34157, 2016-12-01T16:48:20.37140 cas warning: but now two or more servers share the same UDP port. 2016-12-01T16:48:20.37142 cas warning: Depending on your IP kernel this server may not be 2016-12-01T16:48:20.37144 cas warning: reachable with UDP unicast (a host's IP in EPICS_CA_ADDR_LIST) 2016-12-01T16:48:20.37630 TCS_ITMX_CO2 EPICS control prefix: H1:GRD-TCS_ITMX_CO2_ 2016-12-01T16:48:20.37637 TCS_ITMX_CO2 system archive: /ligo/cds/lho/h1/guardian/archive/TCS_ITMX_CO2 2016-12-01T16:49:58.41667 TCS_ITMX_CO2 system archive: id: 63038d969cbb1eba84d19b6396a39550b2397779 (103823577) 2016-12-01T16:49:58.41669 TCS_ITMX_CO2 system name: TCS_ITMX_CO2 2016-12-01T16:49:58.41673 TCS_ITMX_CO2 system CA prefix: TCS-ITMX_CO2 2016-12-01T16:49:58.41681 TCS_ITMX_CO2 module path: /opt/rtcds/userapps/release/tcs/common/guardian/TCS_ITMX_CO2.py 2016-12-01T16:49:58.41682 TCS_ITMX_CO2 user code: /opt/rtcds/userapps/release/tcs/common/guardian/TCS_CO2.py 2016-12-01T16:49:58.41697 TCS_ITMX_CO2 initial state: INIT 2016-12-01T16:49:58.41698 TCS_ITMX_CO2 initial request: LASER_UP 2016-12-01T16:49:58.41701 TCS_ITMX_CO2 nominal state: LASER_UP 2016-12-01T16:49:58.41706 TCS_ITMX_CO2 CA setpoint monitor: False 2016-12-01T16:49:58.41708 TCS_ITMX_CO2 CA setpoint monitor notify: True 2016-12-01T16:49:58.41712 TCS_ITMX_CO2 daemon initialized 2016-12-01T16:49:58.41720 TCS_ITMX_CO2 ============= daemon start ============= 2016-12-01T16:49:58.42868 TCS_ITMX_CO2 W: initialized 2016-12-01T16:49:58.88527 TCS_ITMX_CO2 W: ezca CA prefix: H1:TCS-ITMX_CO2_ 2016-12-01T16:49:58.88537 TCS_ITMX_CO2 W: ready 2016-12-01T16:49:58.88549 TCS_ITMX_CO2 worker ready 2016-12-01T16:49:58.88556 TCS_ITMX_CO2 ========== executing run loop ========== 2016-12-01T16:49:58.91919 TCS_ITMX_CO2 OP: EXEC 2016-12-01T16:49:58.91937 TCS_ITMX_CO2 MODE: AUTO 2016-12-01T16:49:58.92511 TCS_ITMX_CO2 calculating path: INIT->LASER_UP 2016-12-01T16:49:58.92549 TCS_ITMX_CO2 new target: DOWN 2016-12-01T16:49:58.92590 TCS_ITMX_CO2 executing state: INIT (0) 2016-12-01T16:49:58.92598 TCS_ITMX_CO2 [INIT.enter] 2016-12-01T16:49:59.10955 TCS_ITMX_CO2 EDGE: INIT->DOWN 2016-12-01T16:49:59.10979 TCS_ITMX_CO2 calculating path: DOWN->LASER_UP 2016-12-01T16:49:59.11011 TCS_ITMX_CO2 new target: FIND_LOCK_POINT 2016-12-01T16:49:59.11063 TCS_ITMX_CO2 executing state: DOWN (-10) 2016-12-01T16:49:59.11078 TCS_ITMX_CO2 [DOWN.enter] 2016-12-01T16:49:59.35773 TCS_ITMX_CO2 [DOWN.main] ezca: H1:TCS-ITMX_CO2_PZT_SERVO_GAIN_SW2 => 1024 2016-12-01T16:49:59.48315 TCS_ITMX_CO2 [DOWN.main] ezca: H1:TCS-ITMX_CO2_PZT_SERVO_GAIN => OFF: OUTPUT 2016-12-01T16:49:59.49367 TCS_ITMX_CO2 [DOWN.main] ezca: H1:TCS-ITMX_CO2_PZT_SERVO_GAIN_SW1 => 16 2016-12-01T16:49:59.74468 TCS_ITMX_CO2 [DOWN.main] ezca: H1:TCS-ITMX_CO2_PZT_SERVO_GAIN => OFF: FM1 2016-12-01T16:49:59.74481 TCS_ITMX_CO2 [DOWN.main] USERMSG 0: Chiller is more than +/-1.3C away from 20C. Resetting to 20C 2016-12-01T16:49:59.76430 TCS_ITMX_CO2 [DOWN.main] ezca: H1:TCS-ITMX_CO2_CHILLER_SET_POINT_OFFSET => 20 2016-12-01T16:49:59.84538 TCS_ITMX_CO2 [DOWN.main] ezca: H1:TCS-ITMX_CO2_CHILLER_SERVO_GAIN_SW1 => 84 2016-12-01T16:50:00.10630 TCS_ITMX_CO2 [DOWN.main] ezca: H1:TCS-ITMX_CO2_CHILLER_SERVO_GAIN => OFF: INPUT, FM1, FM2 2016-12-01T16:50:00.43168 TCS_ITMX_CO2 [DOWN.main] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT => ON: OFFSET, OUTPUT 2016-12-01T16:50:00.75647 TCS_ITMX_CO2 [DOWN.main] ezca: H1:TCS-ITMX_CO2_CHILLER_SET_POINT => ON: OFFSET, OUTPUT 2016-12-01T16:50:00.76694 TCS_ITMX_CO2 [DOWN.main] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 35 2016-12-01T16:50:00.92493 TCS_ITMX_CO2 EDGE: DOWN->FIND_LOCK_POINT 2016-12-01T16:50:00.92508 TCS_ITMX_CO2 calculating path: FIND_LOCK_POINT->LASER_UP 2016-12-01T16:50:00.92531 TCS_ITMX_CO2 new target: LOCK_LASER 2016-12-01T16:50:00.92563 TCS_ITMX_CO2 executing state: FIND_LOCK_POINT (-12) 2016-12-01T16:50:00.92573 TCS_ITMX_CO2 [FIND_LOCK_POINT.enter] 2016-12-01T16:50:01.17831 TCS_ITMX_CO2 [FIND_LOCK_POINT.main] ezca: H1:TCS-ITMX_CO2_PZT_SERVO_GAIN => OFF: OUTPUT 2016-12-01T16:50:01.43041 TCS_ITMX_CO2 [FIND_LOCK_POINT.main] ezca: H1:TCS-ITMX_CO2_PZT_SERVO_GAIN => OFF: FM1 2016-12-01T16:50:01.68204 TCS_ITMX_CO2 [FIND_LOCK_POINT.main] ezca: H1:TCS-ITMX_CO2_CHILLER_SERVO_GAIN => OFF: INPUT, FM1 2016-12-01T16:50:01.93360 TCS_ITMX_CO2 [FIND_LOCK_POINT.main] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT => ON: OFFSET, OUTPUT 2016-12-01T16:50:01.99216 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 3.5 2016-12-01T16:50:01.99253 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:50:04.99261 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:50:05.06166 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 7.0 2016-12-01T16:50:05.06197 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:50:08.06200 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:50:08.13046 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 10.5 2016-12-01T16:50:08.13069 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:50:11.13083 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:50:11.19938 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 14.0 2016-12-01T16:50:11.19966 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:50:14.19974 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:50:14.27076 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 17.5 2016-12-01T16:50:14.27100 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:50:17.27122 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:50:17.33979 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 21.0 2016-12-01T16:50:17.34015 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:50:20.34036 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:50:20.40960 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 24.5 2016-12-01T16:50:20.40992 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:50:23.41007 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:50:23.47877 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 28.0 2016-12-01T16:50:23.47910 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:50:26.47921 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:50:26.54868 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 31.5 2016-12-01T16:50:26.54905 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:50:29.54913 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:50:29.61813 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 35.0 2016-12-01T16:50:29.61849 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:50:32.61864 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:50:32.68772 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 38.5 2016-12-01T16:50:32.68806 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:50:35.68818 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:50:35.75753 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 42.0 2016-12-01T16:50:35.75795 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:50:38.75844 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:50:38.82808 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 45.5 2016-12-01T16:50:38.82846 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:50:41.82867 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:50:41.89771 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 49.0 2016-12-01T16:50:41.89818 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:50:44.89825 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:50:44.96796 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 52.5 2016-12-01T16:50:44.96831 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:50:47.96853 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:50:48.03797 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 56.0 2016-12-01T16:50:48.03827 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:50:51.03850 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:50:51.10918 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 59.5 2016-12-01T16:50:51.10966 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:50:54.10988 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:50:54.17919 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 63.0 2016-12-01T16:50:54.17951 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:50:57.17999 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:50:57.25010 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 66.5 2016-12-01T16:50:57.25049 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:51:00.25069 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:51:00.31912 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 70.0 2016-12-01T16:51:00.31946 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:51:03.31971 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:51:03.38873 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T16:51:03.38887 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.1855175674, 59.1798636416, 59.1761676443, 59.1570416961, 59.1241927081, 59.0770347164, 59.0210548302, 58.9352615443, 58.8378208211, 58.7287669925, 58.5918546319, 58.7016723419, 59.0161413101, 58.9530977164, 58.7354036682, 58.7792456966, 58.8775521624, 58.9698604543, 59.0435498157, 59.1160215973 2016-12-01T16:51:03.47627 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T16:51:03.47629 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 5 2016-12-01T16:51:03.47633 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 21.0 2016-12-01T16:51:03.47643 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0159942532072 2016-12-01T16:51:03.47717 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [-0.00161541 -0.001056 -0.00546456 -0.00938543 -0.01347371 -0.01599425 2016-12-01T16:51:03.47718 -0.02451237 -0.02784021 -0.03115824 -0.03911782 0.03137649 0.08984828 2016-12-01T16:51:03.47719 -0.01801246 -0.0621983 0.01252629 0.02808756 0.0263738 0.0210541 2016-12-01T16:51:03.47719 0.02070622] 2016-12-01T16:51:03.47720 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -62.5224564752 2016-12-01T16:51:03.47722 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T16:51:03.47733 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 21.0 2016-12-01T16:51:03.47734 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0770347164 2016-12-01T16:51:03.47803 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 21.0 2016-12-01T16:51:03.49626 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LASERPOWER_SETPOINT => 59.0770347164 2016-12-01T16:51:03.52286 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.0770347164 2016-12-01T16:51:03.54963 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SERVO_GAIN_GAIN => 62.5224564752 2016-12-01T16:51:03.55009 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T16:51:03.55050 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T16:51:10.55057 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T16:51:10.58944 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 58.9147621799 2016-12-01T16:51:10.59002 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 58.9147621799 2016-12-01T16:51:10.71403 TCS_ITMX_CO2 EDGE: FIND_LOCK_POINT->LOCK_LASER 2016-12-01T16:51:10.71423 TCS_ITMX_CO2 calculating path: LOCK_LASER->LASER_UP 2016-12-01T16:51:10.71445 TCS_ITMX_CO2 new target: RESET_PZT_VOLTAGE 2016-12-01T16:51:10.71484 TCS_ITMX_CO2 executing state: LOCK_LASER (-16) 2016-12-01T16:51:10.71494 TCS_ITMX_CO2 [LOCK_LASER.enter] 2016-12-01T16:51:11.04145 TCS_ITMX_CO2 [LOCK_LASER.main] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT => ON: OFFSET, OUTPUT 2016-12-01T16:51:11.04211 TCS_ITMX_CO2 [LOCK_LASER.main] ezca: H1:TCS-ITMX_CO2_PZT_SERVO_GAIN_SW1 => 16 2016-12-01T16:51:11.16769 TCS_ITMX_CO2 [LOCK_LASER.main] ezca: H1:TCS-ITMX_CO2_PZT_SERVO_GAIN_SW2 => 1024 2016-12-01T16:51:11.29287 TCS_ITMX_CO2 [LOCK_LASER.main] ezca: H1:TCS-ITMX_CO2_PZT_SERVO_GAIN => ON: FM1, OUTPUT 2016-12-01T16:51:11.46571 TCS_ITMX_CO2 EDGE: LOCK_LASER->RESET_PZT_VOLTAGE 2016-12-01T16:51:11.46589 TCS_ITMX_CO2 calculating path: RESET_PZT_VOLTAGE->LASER_UP 2016-12-01T16:51:11.46610 TCS_ITMX_CO2 new target: ENGAGE_CHILLER_SERVO 2016-12-01T16:51:11.46652 TCS_ITMX_CO2 executing state: RESET_PZT_VOLTAGE (-17) 2016-12-01T16:51:11.46667 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.enter] 2016-12-01T16:51:11.65329 TCS_ITMX_CO2 EDGE: RESET_PZT_VOLTAGE->ENGAGE_CHILLER_SERVO 2016-12-01T16:51:11.65346 TCS_ITMX_CO2 calculating path: ENGAGE_CHILLER_SERVO->LASER_UP 2016-12-01T16:51:11.65367 TCS_ITMX_CO2 new target: ISS_ENGAGE 2016-12-01T16:51:11.65413 TCS_ITMX_CO2 executing state: ENGAGE_CHILLER_SERVO (-11) 2016-12-01T16:51:11.65415 TCS_ITMX_CO2 [ENGAGE_CHILLER_SERVO.enter] 2016-12-01T16:51:11.67635 TCS_ITMX_CO2 [ENGAGE_CHILLER_SERVO.main] ezca: H1:TCS-ITMX_CO2_CHILLER_SERVO_GAIN_SW1 => 84 2016-12-01T16:51:11.92735 TCS_ITMX_CO2 [ENGAGE_CHILLER_SERVO.main] ezca: H1:TCS-ITMX_CO2_CHILLER_SERVO_GAIN => ON: INPUT, FM1, FM2, OUTPUT 2016-12-01T16:51:12.26022 TCS_ITMX_CO2 [ENGAGE_CHILLER_SERVO.main] ezca: H1:TCS-ITMX_CO2_CHILLER_OUT_GAIN => ON: INPUT, OUTPUT 2016-12-01T16:51:12.40519 TCS_ITMX_CO2 EDGE: ENGAGE_CHILLER_SERVO->ISS_ENGAGE 2016-12-01T16:51:12.40539 TCS_ITMX_CO2 calculating path: ISS_ENGAGE->LASER_UP 2016-12-01T16:51:12.40566 TCS_ITMX_CO2 new target: LASER_UP 2016-12-01T16:51:12.40611 TCS_ITMX_CO2 executing state: ISS_ENGAGE (-13) 2016-12-01T16:51:12.40623 TCS_ITMX_CO2 [ISS_ENGAGE.enter] 2016-12-01T16:51:12.59301 TCS_ITMX_CO2 EDGE: ISS_ENGAGE->LASER_UP 2016-12-01T16:51:12.59322 TCS_ITMX_CO2 calculating path: LASER_UP->LASER_UP 2016-12-01T16:51:12.59375 TCS_ITMX_CO2 executing state: LASER_UP (-15) 2016-12-01T16:51:12.59384 TCS_ITMX_CO2 [LASER_UP.enter] 2016-12-01T16:52:09.28234 TCS_ITMX_CO2 [LASER_UP.run] laser unlocked. jumping to find new locking point 2016-12-01T16:52:09.34401 TCS_ITMX_CO2 JUMP target: FIND_LOCK_POINT 2016-12-01T16:52:09.34414 TCS_ITMX_CO2 [LASER_UP.exit] 2016-12-01T16:52:09.40629 TCS_ITMX_CO2 JUMP: LASER_UP->FIND_LOCK_POINT 2016-12-01T16:52:09.40645 TCS_ITMX_CO2 calculating path: FIND_LOCK_POINT->LASER_UP 2016-12-01T16:52:09.40672 TCS_ITMX_CO2 new target: LOCK_LASER 2016-12-01T16:52:09.40713 TCS_ITMX_CO2 executing state: FIND_LOCK_POINT (-12) 2016-12-01T16:52:09.40724 TCS_ITMX_CO2 [FIND_LOCK_POINT.enter] 2016-12-01T16:52:09.53399 TCS_ITMX_CO2 [FIND_LOCK_POINT.main] ezca: H1:TCS-ITMX_CO2_PZT_SERVO_GAIN_SW2 => 1024 2016-12-01T16:52:09.65930 TCS_ITMX_CO2 [FIND_LOCK_POINT.main] ezca: H1:TCS-ITMX_CO2_PZT_SERVO_GAIN => OFF: OUTPUT 2016-12-01T16:52:09.66019 TCS_ITMX_CO2 [FIND_LOCK_POINT.main] ezca: H1:TCS-ITMX_CO2_PZT_SERVO_GAIN_SW1 => 16 2016-12-01T16:52:09.91093 TCS_ITMX_CO2 [FIND_LOCK_POINT.main] ezca: H1:TCS-ITMX_CO2_PZT_SERVO_GAIN => OFF: FM1 2016-12-01T16:52:09.91158 TCS_ITMX_CO2 [FIND_LOCK_POINT.main] ezca: H1:TCS-ITMX_CO2_CHILLER_SERVO_GAIN_SW1 => 20 2016-12-01T16:52:10.16247 TCS_ITMX_CO2 [FIND_LOCK_POINT.main] ezca: H1:TCS-ITMX_CO2_CHILLER_SERVO_GAIN => OFF: INPUT, FM1 2016-12-01T16:52:10.41382 TCS_ITMX_CO2 [FIND_LOCK_POINT.main] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT => ON: OFFSET, OUTPUT 2016-12-01T16:52:10.47337 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 3.5 2016-12-01T16:52:10.47366 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:52:13.47380 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:52:13.53994 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 7.0 2016-12-01T16:52:13.54032 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:52:16.54050 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:52:16.60785 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 10.5 2016-12-01T16:52:16.60810 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:52:19.60836 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:52:19.67601 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 14.0 2016-12-01T16:52:19.67624 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:52:22.67637 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:52:22.74399 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 17.5 2016-12-01T16:52:22.74424 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:52:25.74445 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:52:25.81243 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 21.0 2016-12-01T16:52:25.81265 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:52:28.81277 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:52:28.88208 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 24.5 2016-12-01T16:52:28.88245 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:52:31.88259 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:52:31.94984 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 28.0 2016-12-01T16:52:31.95007 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:52:34.95022 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:52:35.01849 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 31.5 2016-12-01T16:52:35.01871 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:52:38.01901 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:52:38.08607 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 35.0 2016-12-01T16:52:38.08632 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:52:41.08666 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:52:41.15454 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 38.5 2016-12-01T16:52:41.15476 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:52:44.15488 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:52:44.22148 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 42.0 2016-12-01T16:52:44.22170 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:52:47.22184 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:52:47.28955 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 45.5 2016-12-01T16:52:47.28979 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:52:50.29009 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:52:50.35714 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 49.0 2016-12-01T16:52:50.35738 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:52:53.35765 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:52:53.42491 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 52.5 2016-12-01T16:52:53.42521 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:52:56.42536 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:52:56.49204 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 56.0 2016-12-01T16:52:56.49228 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:52:59.49235 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:52:59.55945 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 59.5 2016-12-01T16:52:59.55967 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:53:02.55982 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:53:02.62871 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 63.0 2016-12-01T16:53:02.62900 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:53:05.62918 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:53:05.69616 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 66.5 2016-12-01T16:53:05.69640 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:53:08.69650 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:53:08.76433 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 70.0 2016-12-01T16:53:08.76461 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:53:11.76472 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:53:11.83221 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T16:53:11.83234 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 58.7500951164, 58.587681586, 58.4017831174, 58.606964198, 58.9331070908, 58.6985253092, 58.8970756866, 59.069099957, 59.207418249, 59.3119713753, 59.3961518078, 59.4222232998, 59.4186534242, 59.3588695244, 59.277449783, 59.1369355623, 58.9727523268, 58.7702292907, 58.5316275269, 58.4433147529 2016-12-01T16:53:11.88142 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T16:53:11.88147 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 15 2016-12-01T16:53:11.88153 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 56.0 2016-12-01T16:53:11.88159 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0469094958637 2016-12-01T16:53:11.88212 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [-0.04640387 -0.05311385 0.05862317 0.09318368 -0.06702337 0.05672868 2016-12-01T16:53:11.88213 0.04914979 0.03951951 0.02987232 0.02405155 0.007449 -0.00101996 2016-12-01T16:53:11.88213 -0.01708111 -0.02326278 -0.04014692 -0.0469095 -0.05786372 -0.06817193 2016-12-01T16:53:11.88213 -0.02523222] 2016-12-01T16:53:11.88218 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -21.3176454274 2016-12-01T16:53:11.88222 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T16:53:11.88227 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 56.0 2016-12-01T16:53:11.88232 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.1369355623 2016-12-01T16:53:11.88272 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 56.0 2016-12-01T16:53:11.88320 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LASERPOWER_SETPOINT => 59.1369355623 2016-12-01T16:53:11.88368 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.1369355623 2016-12-01T16:53:11.88404 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SERVO_GAIN_GAIN => 21.3176454274 2016-12-01T16:53:11.88449 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T16:53:11.88477 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T16:53:18.88502 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T16:53:18.91202 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 58.632224147 2016-12-01T16:53:18.91276 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 58.632224147 2016-12-01T16:53:19.03628 TCS_ITMX_CO2 EDGE: FIND_LOCK_POINT->LOCK_LASER 2016-12-01T16:53:19.03645 TCS_ITMX_CO2 calculating path: LOCK_LASER->LASER_UP 2016-12-01T16:53:19.03668 TCS_ITMX_CO2 new target: RESET_PZT_VOLTAGE 2016-12-01T16:53:19.03705 TCS_ITMX_CO2 executing state: LOCK_LASER (-16) 2016-12-01T16:53:19.03719 TCS_ITMX_CO2 [LOCK_LASER.enter] 2016-12-01T16:53:19.29100 TCS_ITMX_CO2 [LOCK_LASER.main] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT => ON: OFFSET, OUTPUT 2016-12-01T16:53:19.29199 TCS_ITMX_CO2 [LOCK_LASER.main] ezca: H1:TCS-ITMX_CO2_PZT_SERVO_GAIN_SW1 => 16 2016-12-01T16:53:19.41967 TCS_ITMX_CO2 [LOCK_LASER.main] ezca: H1:TCS-ITMX_CO2_PZT_SERVO_GAIN_SW2 => 1024 2016-12-01T16:53:19.54498 TCS_ITMX_CO2 [LOCK_LASER.main] ezca: H1:TCS-ITMX_CO2_PZT_SERVO_GAIN => ON: FM1, OUTPUT 2016-12-01T16:53:19.72495 TCS_ITMX_CO2 EDGE: LOCK_LASER->RESET_PZT_VOLTAGE 2016-12-01T16:53:19.72514 TCS_ITMX_CO2 calculating path: RESET_PZT_VOLTAGE->LASER_UP 2016-12-01T16:53:19.72540 TCS_ITMX_CO2 new target: ENGAGE_CHILLER_SERVO 2016-12-01T16:53:19.72583 TCS_ITMX_CO2 executing state: RESET_PZT_VOLTAGE (-17) 2016-12-01T16:53:19.72593 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.enter] 2016-12-01T16:53:19.78960 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 55.671875 2016-12-01T16:53:19.78990 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] timer['wait'] = 0.1 2016-12-01T16:53:19.85218 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 55.34375 2016-12-01T16:53:19.91467 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 55.015625 2016-12-01T16:53:19.97918 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 54.6875 2016-12-01T16:53:20.03978 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 54.359375 2016-12-01T16:53:20.10243 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 54.03125 2016-12-01T16:53:20.16487 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 53.703125 2016-12-01T16:53:20.22770 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 53.375 2016-12-01T16:53:20.28966 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 53.046875 2016-12-01T16:53:20.35352 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 52.71875 2016-12-01T16:53:20.41619 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 52.390625 2016-12-01T16:53:20.47806 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 52.0625 2016-12-01T16:53:20.54280 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 51.734375 2016-12-01T16:53:20.60334 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 51.40625 2016-12-01T16:53:20.66593 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 51.078125 2016-12-01T16:53:20.72860 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 50.75 2016-12-01T16:53:20.79223 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 50.421875 2016-12-01T16:53:20.85575 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 50.09375 2016-12-01T16:53:20.91769 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 49.765625 2016-12-01T16:53:20.98030 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 49.4375 2016-12-01T16:53:21.04268 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 49.109375 2016-12-01T16:53:21.10439 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 48.78125 2016-12-01T16:53:21.16757 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 48.453125 2016-12-01T16:53:21.22946 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 48.125 2016-12-01T16:53:21.29349 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 47.796875 2016-12-01T16:53:21.35525 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 47.46875 2016-12-01T16:53:21.41790 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 47.140625 2016-12-01T16:53:21.48036 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 46.8125 2016-12-01T16:53:21.54299 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 46.484375 2016-12-01T16:53:21.60560 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 46.15625 2016-12-01T16:53:21.66815 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 45.828125 2016-12-01T16:53:21.73084 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 45.5 2016-12-01T16:53:21.79307 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 45.171875 2016-12-01T16:53:21.85600 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 44.84375 2016-12-01T16:53:21.91949 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 44.515625 2016-12-01T16:53:21.98121 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 44.1875 2016-12-01T16:53:22.04387 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 43.859375 2016-12-01T16:53:22.10648 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 43.53125 2016-12-01T16:53:22.16861 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 43.203125 2016-12-01T16:53:22.23175 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 42.875 2016-12-01T16:53:22.29384 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 42.546875 2016-12-01T16:53:22.35681 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 42.21875 2016-12-01T16:53:22.42020 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 41.890625 2016-12-01T16:53:22.48227 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 41.5625 2016-12-01T16:53:22.54460 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 41.234375 2016-12-01T16:53:22.60912 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 40.90625 2016-12-01T16:53:22.67075 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 40.578125 2016-12-01T16:53:22.73324 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 40.25 2016-12-01T16:53:22.79614 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 39.921875 2016-12-01T16:53:22.85969 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 39.59375 2016-12-01T16:53:22.92113 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 39.265625 2016-12-01T16:53:22.98412 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 38.9375 2016-12-01T16:53:23.04619 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 38.609375 2016-12-01T16:53:23.10898 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 38.28125 2016-12-01T16:53:23.17033 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 37.953125 2016-12-01T16:53:23.23412 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 37.625 2016-12-01T16:53:23.29927 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 37.296875 2016-12-01T16:53:23.36322 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 36.96875 2016-12-01T16:53:23.42214 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 36.640625 2016-12-01T16:53:23.48403 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 36.3125 2016-12-01T16:53:23.54754 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 35.984375 2016-12-01T16:53:23.60913 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 35.65625 2016-12-01T16:53:23.67178 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 35.328125 2016-12-01T16:53:23.73463 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 35.0 2016-12-01T16:53:23.83487 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] timer['wait'] done 2016-12-01T16:53:23.92080 TCS_ITMX_CO2 EDGE: RESET_PZT_VOLTAGE->ENGAGE_CHILLER_SERVO 2016-12-01T16:53:23.92102 TCS_ITMX_CO2 calculating path: ENGAGE_CHILLER_SERVO->LASER_UP 2016-12-01T16:53:23.92128 TCS_ITMX_CO2 new target: ISS_ENGAGE 2016-12-01T16:53:23.92175 TCS_ITMX_CO2 executing state: ENGAGE_CHILLER_SERVO (-11) 2016-12-01T16:53:23.92186 TCS_ITMX_CO2 [ENGAGE_CHILLER_SERVO.enter] 2016-12-01T16:53:23.92359 TCS_ITMX_CO2 [ENGAGE_CHILLER_SERVO.main] ezca: H1:TCS-ITMX_CO2_CHILLER_SERVO_GAIN_SW1 => 20 2016-12-01T16:53:24.17450 TCS_ITMX_CO2 [ENGAGE_CHILLER_SERVO.main] ezca: H1:TCS-ITMX_CO2_CHILLER_SERVO_GAIN => ON: INPUT, FM1, FM2, OUTPUT 2016-12-01T16:53:24.42585 TCS_ITMX_CO2 [ENGAGE_CHILLER_SERVO.main] ezca: H1:TCS-ITMX_CO2_CHILLER_OUT_GAIN => ON: INPUT, OUTPUT 2016-12-01T16:53:24.60978 TCS_ITMX_CO2 EDGE: ENGAGE_CHILLER_SERVO->ISS_ENGAGE 2016-12-01T16:53:24.61004 TCS_ITMX_CO2 calculating path: ISS_ENGAGE->LASER_UP 2016-12-01T16:53:24.61017 TCS_ITMX_CO2 new target: LASER_UP 2016-12-01T16:53:24.61055 TCS_ITMX_CO2 executing state: ISS_ENGAGE (-13) 2016-12-01T16:53:24.61074 TCS_ITMX_CO2 [ISS_ENGAGE.enter] 2016-12-01T16:53:24.79741 TCS_ITMX_CO2 EDGE: ISS_ENGAGE->LASER_UP 2016-12-01T16:53:24.79763 TCS_ITMX_CO2 calculating path: LASER_UP->LASER_UP 2016-12-01T16:53:24.79809 TCS_ITMX_CO2 executing state: LASER_UP (-15) 2016-12-01T16:53:24.79820 TCS_ITMX_CO2 [LASER_UP.enter] 2016-12-01T16:55:17.91056 TCS_ITMX_CO2 [LASER_UP.run] laser unlocked. jumping to find new locking point 2016-12-01T16:55:17.97344 TCS_ITMX_CO2 JUMP target: FIND_LOCK_POINT 2016-12-01T16:55:17.97364 TCS_ITMX_CO2 [LASER_UP.exit] 2016-12-01T16:55:18.03508 TCS_ITMX_CO2 JUMP: LASER_UP->FIND_LOCK_POINT 2016-12-01T16:55:18.03537 TCS_ITMX_CO2 calculating path: FIND_LOCK_POINT->LASER_UP 2016-12-01T16:55:18.03572 TCS_ITMX_CO2 new target: LOCK_LASER 2016-12-01T16:55:18.03635 TCS_ITMX_CO2 executing state: FIND_LOCK_POINT (-12) 2016-12-01T16:55:18.03652 TCS_ITMX_CO2 [FIND_LOCK_POINT.enter] 2016-12-01T16:55:18.16522 TCS_ITMX_CO2 [FIND_LOCK_POINT.main] ezca: H1:TCS-ITMX_CO2_PZT_SERVO_GAIN_SW2 => 1024 2016-12-01T16:55:18.29198 TCS_ITMX_CO2 [FIND_LOCK_POINT.main] ezca: H1:TCS-ITMX_CO2_PZT_SERVO_GAIN => OFF: OUTPUT 2016-12-01T16:55:18.29296 TCS_ITMX_CO2 [FIND_LOCK_POINT.main] ezca: H1:TCS-ITMX_CO2_PZT_SERVO_GAIN_SW1 => 16 2016-12-01T16:55:18.54408 TCS_ITMX_CO2 [FIND_LOCK_POINT.main] ezca: H1:TCS-ITMX_CO2_PZT_SERVO_GAIN => OFF: FM1 2016-12-01T16:55:18.54757 TCS_ITMX_CO2 [FIND_LOCK_POINT.main] ezca: H1:TCS-ITMX_CO2_CHILLER_SERVO_GAIN_SW1 => 20 2016-12-01T16:55:18.79894 TCS_ITMX_CO2 [FIND_LOCK_POINT.main] ezca: H1:TCS-ITMX_CO2_CHILLER_SERVO_GAIN => OFF: INPUT, FM1 2016-12-01T16:55:19.05242 TCS_ITMX_CO2 [FIND_LOCK_POINT.main] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT => ON: OFFSET, OUTPUT 2016-12-01T16:55:19.10317 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 3.5 2016-12-01T16:55:19.10364 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:55:22.10367 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:55:22.17056 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 7.0 2016-12-01T16:55:22.17083 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:55:25.17105 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:55:25.24935 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 10.5 2016-12-01T16:55:25.24963 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:55:28.25003 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:55:28.31596 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 14.0 2016-12-01T16:55:28.31637 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:55:31.31648 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:55:31.38731 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 17.5 2016-12-01T16:55:31.38759 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:55:34.38791 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:55:34.46378 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 21.0 2016-12-01T16:55:34.46406 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:55:37.46428 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:55:37.53812 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 24.5 2016-12-01T16:55:37.53840 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:55:40.53852 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:55:40.60489 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 28.0 2016-12-01T16:55:40.60513 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:55:43.60528 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:55:43.68124 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 31.5 2016-12-01T16:55:43.68150 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:55:46.68162 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:55:46.74760 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 35.0 2016-12-01T16:55:46.74786 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:55:49.74806 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:55:49.82043 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 38.5 2016-12-01T16:55:49.82074 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:55:52.82099 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:55:52.88902 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 42.0 2016-12-01T16:55:52.88926 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:55:55.89424 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:55:55.95923 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 45.5 2016-12-01T16:55:55.95947 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:55:58.95961 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:55:59.03151 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 49.0 2016-12-01T16:55:59.03178 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:56:02.03458 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:56:02.10767 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 52.5 2016-12-01T16:56:02.10795 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:56:05.10898 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:56:05.17880 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 56.0 2016-12-01T16:56:05.17904 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:56:08.17917 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:56:08.25649 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 59.5 2016-12-01T16:56:08.25676 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:56:11.25693 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:56:11.32623 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 63.0 2016-12-01T16:56:11.32649 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:56:14.32663 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:56:14.39641 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 66.5 2016-12-01T16:56:14.39697 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:56:17.39731 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:56:17.46730 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 70.0 2016-12-01T16:56:17.46761 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:56:20.46798 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:56:20.54183 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T16:56:20.54194 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 58.3808501479, 58.5771609379, 58.7334478365, 58.6056739172, 58.8044781612, 58.9926260023, 59.1627411952, 59.3048610259, 59.4146542777, 59.4949961989, 59.53405727, 59.5398114302, 59.4966830078, 59.4077326666, 59.2799918169, 59.1212398552, 58.9149762011, 58.6834799062, 58.6201703739, 58.906808643 2016-12-01T16:56:20.60995 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, positive slope 1 2016-12-01T16:56:20.60999 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 7 2016-12-01T16:56:20.61005 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 28.0 2016-12-01T16:56:20.61011 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope 0.0313695005278 2016-12-01T16:56:20.61064 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.0560888 0.0446534 -0.03650683 0.05680121 0.05375653 0.04860434 2016-12-01T16:56:20.61065 0.04060567 0.0313695 0.02295483 0.01116031 0.00164405 -0.01232241 2016-12-01T16:56:20.61066 -0.02541438 -0.03649739 -0.0453577 -0.05893247 -0.0661418 -0.01808844 2016-12-01T16:56:20.61067 0.08189665] 2016-12-01T16:56:20.61070 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is 31.8780976163 2016-12-01T16:56:20.61076 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 1 2016-12-01T16:56:20.61082 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 28.0 2016-12-01T16:56:20.61088 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3048610259 2016-12-01T16:56:20.61737 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 28.0 2016-12-01T16:56:20.61813 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LASERPOWER_SETPOINT => 59.3048610259 2016-12-01T16:56:20.61864 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3048610259 2016-12-01T16:56:20.61908 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SERVO_GAIN_GAIN => -31.8780976163 2016-12-01T16:56:20.61943 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T16:56:20.61969 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T16:56:27.61981 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T16:56:27.62578 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.3899744301 2016-12-01T16:56:27.62747 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3899744301 2016-12-01T16:56:27.74987 TCS_ITMX_CO2 EDGE: FIND_LOCK_POINT->LOCK_LASER 2016-12-01T16:56:27.75014 TCS_ITMX_CO2 calculating path: LOCK_LASER->LASER_UP 2016-12-01T16:56:27.75041 TCS_ITMX_CO2 new target: RESET_PZT_VOLTAGE 2016-12-01T16:56:27.75088 TCS_ITMX_CO2 executing state: LOCK_LASER (-16) 2016-12-01T16:56:27.75102 TCS_ITMX_CO2 [LOCK_LASER.enter] 2016-12-01T16:56:28.00288 TCS_ITMX_CO2 [LOCK_LASER.main] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT => ON: OFFSET, OUTPUT 2016-12-01T16:56:28.00510 TCS_ITMX_CO2 [LOCK_LASER.main] ezca: H1:TCS-ITMX_CO2_PZT_SERVO_GAIN_SW1 => 16 2016-12-01T16:56:28.13081 TCS_ITMX_CO2 [LOCK_LASER.main] ezca: H1:TCS-ITMX_CO2_PZT_SERVO_GAIN_SW2 => 1024 2016-12-01T16:56:28.25606 TCS_ITMX_CO2 [LOCK_LASER.main] ezca: H1:TCS-ITMX_CO2_PZT_SERVO_GAIN => ON: FM1, OUTPUT 2016-12-01T16:56:28.43877 TCS_ITMX_CO2 EDGE: LOCK_LASER->RESET_PZT_VOLTAGE 2016-12-01T16:56:28.43900 TCS_ITMX_CO2 calculating path: RESET_PZT_VOLTAGE->LASER_UP 2016-12-01T16:56:28.43927 TCS_ITMX_CO2 new target: ENGAGE_CHILLER_SERVO 2016-12-01T16:56:28.43974 TCS_ITMX_CO2 executing state: RESET_PZT_VOLTAGE (-17) 2016-12-01T16:56:28.43986 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.enter] 2016-12-01T16:56:28.62658 TCS_ITMX_CO2 EDGE: RESET_PZT_VOLTAGE->ENGAGE_CHILLER_SERVO 2016-12-01T16:56:28.62678 TCS_ITMX_CO2 calculating path: ENGAGE_CHILLER_SERVO->LASER_UP 2016-12-01T16:56:28.62700 TCS_ITMX_CO2 new target: ISS_ENGAGE 2016-12-01T16:56:28.62741 TCS_ITMX_CO2 executing state: ENGAGE_CHILLER_SERVO (-11) 2016-12-01T16:56:28.62751 TCS_ITMX_CO2 [ENGAGE_CHILLER_SERVO.enter] 2016-12-01T16:56:28.62886 TCS_ITMX_CO2 [ENGAGE_CHILLER_SERVO.main] ezca: H1:TCS-ITMX_CO2_CHILLER_SERVO_GAIN_SW1 => 20 2016-12-01T16:56:28.87996 TCS_ITMX_CO2 [ENGAGE_CHILLER_SERVO.main] ezca: H1:TCS-ITMX_CO2_CHILLER_SERVO_GAIN => ON: INPUT, FM1, FM2, OUTPUT 2016-12-01T16:56:29.13120 TCS_ITMX_CO2 [ENGAGE_CHILLER_SERVO.main] ezca: H1:TCS-ITMX_CO2_CHILLER_OUT_GAIN => ON: INPUT, OUTPUT 2016-12-01T16:56:29.31718 TCS_ITMX_CO2 EDGE: ENGAGE_CHILLER_SERVO->ISS_ENGAGE 2016-12-01T16:56:29.31738 TCS_ITMX_CO2 calculating path: ISS_ENGAGE->LASER_UP 2016-12-01T16:56:29.31759 TCS_ITMX_CO2 new target: LASER_UP 2016-12-01T16:56:29.31796 TCS_ITMX_CO2 executing state: ISS_ENGAGE (-13) 2016-12-01T16:56:29.31809 TCS_ITMX_CO2 [ISS_ENGAGE.enter] 2016-12-01T16:56:29.50499 TCS_ITMX_CO2 EDGE: ISS_ENGAGE->LASER_UP 2016-12-01T16:56:29.50524 TCS_ITMX_CO2 calculating path: LASER_UP->LASER_UP 2016-12-01T16:56:29.50572 TCS_ITMX_CO2 executing state: LASER_UP (-15) 2016-12-01T16:56:29.50586 TCS_ITMX_CO2 [LASER_UP.enter] 2016-12-01T16:56:30.88675 TCS_ITMX_CO2 [LASER_UP.run] laser unlocked. jumping to find new locking point 2016-12-01T16:56:30.94911 TCS_ITMX_CO2 JUMP target: FIND_LOCK_POINT 2016-12-01T16:56:30.94923 TCS_ITMX_CO2 [LASER_UP.exit] 2016-12-01T16:56:31.01210 TCS_ITMX_CO2 JUMP: LASER_UP->FIND_LOCK_POINT 2016-12-01T16:56:31.01230 TCS_ITMX_CO2 calculating path: FIND_LOCK_POINT->LASER_UP 2016-12-01T16:56:31.01257 TCS_ITMX_CO2 new target: LOCK_LASER 2016-12-01T16:56:31.01304 TCS_ITMX_CO2 executing state: FIND_LOCK_POINT (-12) 2016-12-01T16:56:31.01318 TCS_ITMX_CO2 [FIND_LOCK_POINT.enter] 2016-12-01T16:56:31.14111 TCS_ITMX_CO2 [FIND_LOCK_POINT.main] ezca: H1:TCS-ITMX_CO2_PZT_SERVO_GAIN_SW2 => 1024 2016-12-01T16:56:31.26652 TCS_ITMX_CO2 [FIND_LOCK_POINT.main] ezca: H1:TCS-ITMX_CO2_PZT_SERVO_GAIN => OFF: OUTPUT 2016-12-01T16:56:31.26761 TCS_ITMX_CO2 [FIND_LOCK_POINT.main] ezca: H1:TCS-ITMX_CO2_PZT_SERVO_GAIN_SW1 => 16 2016-12-01T16:56:31.52057 TCS_ITMX_CO2 [FIND_LOCK_POINT.main] ezca: H1:TCS-ITMX_CO2_PZT_SERVO_GAIN => OFF: FM1 2016-12-01T16:56:31.52197 TCS_ITMX_CO2 [FIND_LOCK_POINT.main] ezca: H1:TCS-ITMX_CO2_CHILLER_SERVO_GAIN_SW1 => 20 2016-12-01T16:56:31.77309 TCS_ITMX_CO2 [FIND_LOCK_POINT.main] ezca: H1:TCS-ITMX_CO2_CHILLER_SERVO_GAIN => OFF: INPUT, FM1 2016-12-01T16:56:32.02436 TCS_ITMX_CO2 [FIND_LOCK_POINT.main] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT => ON: OFFSET, OUTPUT 2016-12-01T16:56:32.08211 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 3.5 2016-12-01T16:56:32.08240 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:56:35.08416 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:56:35.17161 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 7.0 2016-12-01T16:56:35.17197 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:56:38.17230 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:56:38.24445 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 10.5 2016-12-01T16:56:38.24447 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:56:41.24221 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:56:41.32703 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 14.0 2016-12-01T16:56:41.32751 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:56:44.32777 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:56:44.43144 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 17.5 2016-12-01T16:56:44.43841 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:56:47.43208 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:56:47.50716 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 21.0 2016-12-01T16:56:47.50755 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:56:50.50789 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:56:50.59334 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 24.5 2016-12-01T16:56:50.59345 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:56:53.59360 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:56:53.67710 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 28.0 2016-12-01T16:56:53.67742 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:56:56.67776 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:56:56.75960 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 31.5 2016-12-01T16:56:56.76005 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:56:59.76281 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:56:59.83688 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 35.0 2016-12-01T16:56:59.83707 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:57:02.83725 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:57:02.92285 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 38.5 2016-12-01T16:57:02.92312 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:57:05.92341 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:57:06.00171 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 42.0 2016-12-01T16:57:06.00200 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:57:09.00195 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:57:09.08617 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 45.5 2016-12-01T16:57:09.08649 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:57:12.08659 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:57:12.16396 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 49.0 2016-12-01T16:57:12.16791 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:57:15.16496 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:57:15.24455 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 52.5 2016-12-01T16:57:15.24524 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:57:18.24556 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:57:18.31769 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 56.0 2016-12-01T16:57:18.31798 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:57:21.31794 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:57:21.40375 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 59.5 2016-12-01T16:57:21.40425 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:57:24.40460 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:57:24.47457 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 63.0 2016-12-01T16:57:24.47569 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:57:27.47539 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:57:27.54884 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 66.5 2016-12-01T16:57:27.54908 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:57:30.54920 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:57:30.63317 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 70.0 2016-12-01T16:57:30.63335 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:57:33.63370 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:57:33.70892 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T16:57:33.70903 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3145708825, 59.3639759534, 59.3920959858, 59.4006991625, 59.3839711297, 59.3361159443, 59.2704240955, 59.155190545, 59.0224183194, 58.8516974407, 58.6527006133, 58.73187127, 59.1373784102, 58.9744777137, 59.0726125832, 59.2198841108, 59.3482638306, 59.4398327351, 59.4965924368, 59.5187926161 2016-12-01T16:57:33.73888 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheckfail 0 2016-12-01T16:57:33.73890 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.01411573 0.00803429 0.00245805 -0.00477944 -0.01367291 -0.0187691 2016-12-01T16:57:33.73891 -0.03292387 -0.03793492 -0.04877739 -0.05685624 0.02262019 0.11585918 2016-12-01T16:57:33.73891 -0.04654306 0.02803853 0.04207758 0.03667992 0.02616254 0.01621706 2016-12-01T16:57:33.73892 0.00634291] 2016-12-01T16:57:33.73892 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is 70.8429303524 2016-12-01T16:57:33.73893 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 0 2016-12-01T16:57:33.73893 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5 2016-12-01T16:57:33.73894 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3145708825 2016-12-01T16:57:33.73894 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] current chiller setpoint 20.0 2016-12-01T16:57:33.74025 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_CHILLER_SET_POINT_OFFSET => 20.1 2016-12-01T16:57:33.74038 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: connecting to ifo-rooted channel: H1:DAQ-DC0_GPS 2016-12-01T16:57:33.78178 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_CHILLER_TSTEP => 1164646670.0 2016-12-01T16:57:33.78192 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] new chiller setpoint 20.1 2016-12-01T16:57:33.78248 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['chillerstep'] = 240 2016-12-01T16:57:33.78249 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] no setpoint found:stepping chiller temp 2016-12-01T16:58:54.24890 TCS_ITMX_CO2 REQUEST: FIND_LOCK_POINT 2016-12-01T16:58:54.24892 TCS_ITMX_CO2 calculating path: FIND_LOCK_POINT->FIND_LOCK_POINT 2016-12-01T16:58:54.24904 TCS_ITMX_CO2 new target: FIND_LOCK_POINT 2016-12-01T16:58:54.24913 TCS_ITMX_CO2 same state request redirect 2016-12-01T16:58:54.24934 TCS_ITMX_CO2 REDIRECT requested, timeout in 1.000 seconds 2016-12-01T16:58:54.25007 TCS_ITMX_CO2 REDIRECT caught 2016-12-01T16:58:54.25031 TCS_ITMX_CO2 [FIND_LOCK_POINT.redirect] 2016-12-01T16:58:54.31186 TCS_ITMX_CO2 executing state: FIND_LOCK_POINT (-12) 2016-12-01T16:58:54.31214 TCS_ITMX_CO2 [FIND_LOCK_POINT.enter] 2016-12-01T16:58:54.56969 TCS_ITMX_CO2 [FIND_LOCK_POINT.main] ezca: H1:TCS-ITMX_CO2_PZT_SERVO_GAIN => OFF: OUTPUT 2016-12-01T16:58:54.82508 TCS_ITMX_CO2 [FIND_LOCK_POINT.main] ezca: H1:TCS-ITMX_CO2_PZT_SERVO_GAIN => OFF: FM1 2016-12-01T16:58:55.07798 TCS_ITMX_CO2 [FIND_LOCK_POINT.main] ezca: H1:TCS-ITMX_CO2_CHILLER_SERVO_GAIN => OFF: INPUT, FM1 2016-12-01T16:58:55.33099 TCS_ITMX_CO2 [FIND_LOCK_POINT.main] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT => ON: OFFSET, OUTPUT 2016-12-01T16:58:55.38202 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 3.5 2016-12-01T16:58:55.38230 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:58:58.38344 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:58:58.46143 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 7.0 2016-12-01T16:58:58.46260 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:59:01.46186 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:59:01.54001 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 10.5 2016-12-01T16:59:01.54042 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:59:04.54075 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:59:04.62210 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 14.0 2016-12-01T16:59:04.62261 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:59:07.62176 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:59:07.70861 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 17.5 2016-12-01T16:59:07.70892 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:59:10.70917 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:59:10.78387 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 21.0 2016-12-01T16:59:10.78416 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:59:13.78741 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:59:13.86368 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 24.5 2016-12-01T16:59:13.86408 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:59:16.86459 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:59:16.94122 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 28.0 2016-12-01T16:59:16.94149 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:59:19.94198 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:59:20.02444 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 31.5 2016-12-01T16:59:20.02629 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:59:23.02695 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:59:23.10282 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 35.0 2016-12-01T16:59:23.10317 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:59:26.10316 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:59:26.18776 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 38.5 2016-12-01T16:59:26.19154 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:59:29.18998 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:59:29.27376 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 42.0 2016-12-01T16:59:29.27404 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:59:32.27709 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:59:32.35397 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 45.5 2016-12-01T16:59:32.35444 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:59:35.35523 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:59:35.43468 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 49.0 2016-12-01T16:59:35.43498 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:59:38.43521 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:59:38.51117 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 52.5 2016-12-01T16:59:38.51154 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:59:41.51276 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:59:41.59011 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 56.0 2016-12-01T16:59:41.59045 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:59:44.59072 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:59:44.66995 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 59.5 2016-12-01T16:59:44.67028 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:59:47.67291 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:59:47.74566 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 63.0 2016-12-01T16:59:47.74621 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:59:50.74649 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:59:50.82105 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 66.5 2016-12-01T16:59:50.82118 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:59:53.82134 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:59:53.90532 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 70.0 2016-12-01T16:59:53.90584 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T16:59:56.90599 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T16:59:56.98293 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T16:59:56.98295 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T16:59:57.02121 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T16:59:57.02123 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T16:59:57.02124 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T16:59:57.02124 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T16:59:57.02212 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T16:59:57.02214 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T16:59:57.02214 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T16:59:57.02215 0.03121747] 2016-12-01T16:59:57.02226 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T16:59:57.02237 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T16:59:57.02248 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T16:59:57.02258 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T16:59:57.02586 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 42.0 2016-12-01T16:59:57.02648 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LASERPOWER_SETPOINT => 59.3455004347 2016-12-01T16:59:57.02707 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T16:59:57.02772 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SERVO_GAIN_GAIN => 22.2992990423 2016-12-01T16:59:57.02938 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T16:59:57.02998 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:00:04.03065 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:00:04.09113 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 58.6555421934 2016-12-01T17:00:04.09373 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 58.6555421934 2016-12-01T17:00:04.15334 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:00:04.15337 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:00:04.19151 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:00:04.19307 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:00:04.19308 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:00:04.19309 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:00:04.19309 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:00:04.19310 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:00:04.19312 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:00:04.19313 0.03121747] 2016-12-01T17:00:04.19313 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:00:04.19314 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:00:04.19314 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:00:04.19315 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:00:04.19394 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:00:04.19458 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:00:04.19496 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:00:11.19559 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:00:11.24604 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 58.855917813 2016-12-01T17:00:11.24752 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 58.855917813 2016-12-01T17:00:11.30925 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:00:11.30927 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:00:11.35015 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:00:11.35017 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:00:11.35017 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:00:11.35018 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:00:11.35018 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:00:11.35019 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:00:11.35019 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:00:11.35020 0.03121747] 2016-12-01T17:00:11.35020 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:00:11.35021 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:00:11.35021 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:00:11.35021 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:00:11.36625 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:00:11.38032 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:00:11.38465 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:00:18.38107 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:00:18.43229 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.0758774886 2016-12-01T17:00:18.43281 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.0758774886 2016-12-01T17:00:18.49477 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:00:18.49489 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:00:18.51866 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:00:18.51868 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:00:18.51869 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:00:18.51869 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:00:18.51871 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:00:18.51871 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:00:18.51872 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:00:18.51872 0.03121747] 2016-12-01T17:00:18.51873 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:00:18.51873 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:00:18.51874 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:00:18.51874 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:00:18.51972 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:00:18.52652 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:00:18.52655 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:00:25.52697 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:00:25.53517 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.0001516428 2016-12-01T17:00:25.53923 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.0001516428 2016-12-01T17:00:25.59848 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:00:25.59849 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:00:25.63949 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:00:25.63951 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:00:25.63952 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:00:25.63952 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:00:25.63953 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:00:25.63953 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:00:25.63954 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:00:25.63954 0.03121747] 2016-12-01T17:00:25.63955 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:00:25.63955 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:00:25.63956 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:00:25.63956 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:00:25.64050 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:00:25.64109 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:00:25.64158 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:00:32.64251 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:00:32.69927 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 58.9465851354 2016-12-01T17:00:32.70049 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 58.9465851354 2016-12-01T17:00:32.76187 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:00:32.76226 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:00:32.81834 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:00:32.81837 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:00:32.81837 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:00:32.81838 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:00:32.82063 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:00:32.82064 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:00:32.82065 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:00:32.82065 0.03121747] 2016-12-01T17:00:32.82066 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:00:32.82066 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:00:32.82067 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:00:32.82067 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:00:32.82367 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:00:32.82436 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:00:32.82518 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:00:39.82522 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:00:39.86907 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 58.8937546351 2016-12-01T17:00:39.86992 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 58.8937546351 2016-12-01T17:00:39.92645 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:00:39.92647 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:00:39.95358 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:00:39.95383 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:00:39.95395 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:00:39.95411 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:00:39.95532 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:00:39.95533 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:00:39.95534 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:00:39.95535 0.03121747] 2016-12-01T17:00:39.95551 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:00:39.95564 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:00:39.95577 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:00:39.95590 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:00:39.95706 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:00:39.95794 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:00:39.95978 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:00:46.95932 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:00:46.96995 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 58.8583634591 2016-12-01T17:00:46.97188 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 58.8583634591 2016-12-01T17:00:47.03540 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:00:47.03542 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:00:47.06911 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:00:47.06913 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:00:47.06914 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:00:47.06914 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:00:47.06915 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:00:47.06915 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:00:47.06916 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:00:47.06916 0.03121747] 2016-12-01T17:00:47.06917 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:00:47.06917 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:00:47.06918 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:00:47.06918 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:00:47.07643 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:00:47.07780 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:00:47.07812 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:00:54.07993 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:00:54.13753 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 58.8287470559 2016-12-01T17:00:54.14041 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 58.8287470559 2016-12-01T17:00:54.19976 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:00:54.19992 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:00:54.23629 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:00:54.23631 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:00:54.23631 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:00:54.23632 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:00:54.23632 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:00:54.23633 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:00:54.23633 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:00:54.23634 0.03121747] 2016-12-01T17:00:54.23634 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:00:54.23635 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:00:54.23635 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:00:54.23636 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:00:54.23938 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:00:54.24582 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:00:54.24606 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:01:01.24637 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:01:01.30256 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 58.895378165 2016-12-01T17:01:01.30377 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 58.895378165 2016-12-01T17:01:01.36466 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:01:01.36478 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:01:01.42001 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:01:01.42173 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:01:01.42174 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:01:01.42175 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:01:01.42175 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:01:01.42176 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:01:01.42176 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:01:01.42177 0.03121747] 2016-12-01T17:01:01.42177 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:01:01.42178 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:01:01.42178 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:01:01.42179 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:01:01.42695 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:01:01.42790 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:01:01.43107 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:01:08.43151 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:01:08.46440 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 58.9476408914 2016-12-01T17:01:08.47072 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 58.9476408914 2016-12-01T17:01:08.52888 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:01:08.52890 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:01:08.58768 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:01:08.58770 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:01:08.58771 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:01:08.58771 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:01:08.58771 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:01:08.58772 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:01:08.58772 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:01:08.58772 0.03121747] 2016-12-01T17:01:08.58773 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:01:08.58773 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:01:08.58773 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:01:08.58773 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:01:08.59014 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:01:08.59299 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:01:08.59312 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:01:15.59355 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:01:15.63376 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.0081382161 2016-12-01T17:01:15.63783 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.0081382161 2016-12-01T17:01:15.69229 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:01:15.69241 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:01:15.72965 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:01:15.73094 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:01:15.73095 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:01:15.73096 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:01:15.73096 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:01:15.73097 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:01:15.73097 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:01:15.73098 0.03121747] 2016-12-01T17:01:15.73098 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:01:15.73099 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:01:15.73099 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:01:15.73099 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:01:15.73186 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:01:15.73766 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:01:15.73796 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:01:22.73929 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:01:22.74013 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.06706473 2016-12-01T17:01:22.74095 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.06706473 2016-12-01T17:01:22.80299 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:01:22.80301 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:01:23.38107 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:01:23.38109 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:01:23.38109 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:01:23.38110 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:01:23.38110 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:01:23.38111 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:01:23.38111 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:01:23.38112 0.03121747] 2016-12-01T17:01:23.38112 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:01:23.38113 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:01:23.38113 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:01:23.38114 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:01:23.38922 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:01:23.39054 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:01:23.39112 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:01:30.39145 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:01:30.41024 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.1323888626 2016-12-01T17:01:30.41419 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.1323888626 2016-12-01T17:01:30.47150 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:01:30.47153 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:01:30.63405 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:01:30.63407 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:01:30.63408 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:01:30.63408 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:01:30.63409 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:01:30.63409 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:01:30.63410 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:01:30.63410 0.03121747] 2016-12-01T17:01:30.63411 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:01:30.63411 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:01:30.63412 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:01:30.63413 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:01:30.63558 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:01:30.63645 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:01:30.63940 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:01:37.63885 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:01:37.69397 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.1919771581 2016-12-01T17:01:37.69727 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.1919771581 2016-12-01T17:01:37.75965 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:01:37.75985 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:01:38.21119 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:01:38.21133 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:01:38.21145 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:01:38.21156 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:01:38.21251 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:01:38.21252 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:01:38.21253 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:01:38.21253 0.03121747] 2016-12-01T17:01:38.21265 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:01:38.21275 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:01:38.21287 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:01:38.21298 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:01:38.22115 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:01:38.22789 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:01:38.22828 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:01:45.23071 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:01:45.23580 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.2393996725 2016-12-01T17:01:45.23648 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.2393996725 2016-12-01T17:01:45.30030 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:01:45.30034 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:01:45.33025 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:01:45.33027 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:01:45.33028 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:01:45.33028 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:01:45.33029 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:01:45.33029 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:01:45.33030 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:01:45.33030 0.03121747] 2016-12-01T17:01:45.33030 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:01:45.33031 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:01:45.33031 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:01:45.33032 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:01:45.33309 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:01:45.33365 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:01:45.33399 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:01:52.33464 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:01:52.34168 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.2936126455 2016-12-01T17:01:52.34257 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.2936126455 2016-12-01T17:01:52.40552 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:01:52.40572 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:01:52.45777 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:01:52.45785 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:01:52.45797 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:01:52.45808 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:01:52.45905 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:01:52.45906 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:01:52.45906 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:01:52.45907 0.03121747] 2016-12-01T17:01:52.45924 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:01:52.45935 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:01:52.45945 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:01:52.45956 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:01:52.46520 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:01:52.46585 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:01:52.46616 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:01:59.46640 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:01:59.50328 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.3380126288 2016-12-01T17:01:59.50780 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3380126288 2016-12-01T17:01:59.56765 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:01:59.56779 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:01:59.64220 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:01:59.64223 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:01:59.64223 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:01:59.64224 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:01:59.64224 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:01:59.64225 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:01:59.64225 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:01:59.64226 0.03121747] 2016-12-01T17:01:59.64226 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:01:59.64227 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:01:59.64227 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:01:59.64228 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:01:59.65624 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:01:59.66229 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:01:59.66262 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:02:06.66540 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:02:06.72508 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.3726959778 2016-12-01T17:02:06.72629 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3726959778 2016-12-01T17:02:06.79187 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:02:06.79214 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:02:06.83401 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:02:06.83403 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:02:06.83404 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:02:06.83404 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:02:06.83405 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:02:06.83406 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:02:06.83407 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:02:06.83407 0.03121747] 2016-12-01T17:02:06.83408 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:02:06.83408 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:02:06.83409 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:02:06.83409 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:02:06.83608 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:02:06.83672 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:02:06.83719 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:02:13.83776 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:02:13.88204 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.4018710129 2016-12-01T17:02:13.88297 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.4018710129 2016-12-01T17:02:13.94106 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:02:13.94108 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:02:13.98451 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:02:13.98457 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:02:13.98465 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:02:13.98473 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:02:13.98555 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:02:13.98556 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:02:13.98557 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:02:13.98557 0.03121747] 2016-12-01T17:02:13.98563 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:02:13.98570 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:02:13.98581 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:02:13.98584 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:02:13.99199 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:02:13.99539 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:02:13.99749 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:02:20.99595 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:02:21.03876 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.4288898188 2016-12-01T17:02:21.04279 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.4288898188 2016-12-01T17:02:21.10257 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:02:21.10284 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:02:21.15204 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:02:21.15206 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:02:21.15208 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:02:21.15209 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:02:21.15280 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:02:21.15281 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:02:21.15281 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:02:21.15282 0.03121747] 2016-12-01T17:02:21.15282 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:02:21.15283 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:02:21.15283 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:02:21.15284 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:02:21.15897 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:02:21.16107 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:02:21.16138 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:02:28.16162 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:02:28.19906 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.4449172553 2016-12-01T17:02:28.19953 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.4449172553 2016-12-01T17:02:28.26513 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:02:28.26515 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:02:28.64695 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:02:28.64696 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:02:28.64697 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:02:28.64697 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:02:28.64698 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:02:28.64698 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:02:28.64699 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:02:28.64700 0.03121747] 2016-12-01T17:02:28.64700 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:02:28.64701 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:02:28.64701 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:02:28.64702 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:02:28.66012 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:02:28.66357 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:02:28.66370 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:02:35.66547 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:02:35.68934 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.4596359728 2016-12-01T17:02:35.69049 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.4596359728 2016-12-01T17:02:35.75388 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:02:35.75391 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:02:35.79053 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:02:35.79054 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:02:35.79055 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:02:35.79055 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:02:35.79415 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:02:35.79417 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:02:35.79417 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:02:35.79418 0.03121747] 2016-12-01T17:02:35.79418 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:02:35.79419 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:02:35.79419 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:02:35.79420 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:02:35.79696 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:02:35.79857 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:02:35.79895 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:02:42.80154 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:02:42.85711 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.4754653621 2016-12-01T17:02:42.85799 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.4754653621 2016-12-01T17:02:42.92028 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:02:42.92030 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:02:42.99868 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:02:42.99870 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:02:42.99871 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:02:42.99871 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:02:42.99978 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:02:42.99979 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:02:42.99980 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:02:42.99980 0.03121747] 2016-12-01T17:02:43.00030 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:02:43.00031 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:02:43.00032 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:02:43.00032 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:02:43.01441 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:02:43.01779 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:02:43.01802 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:02:50.01826 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:02:50.02578 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.4772492516 2016-12-01T17:02:50.03430 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.4772492516 2016-12-01T17:02:50.09032 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:02:50.09048 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:02:50.15059 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:02:50.15071 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:02:50.15084 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:02:50.15092 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:02:50.15186 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:02:50.15187 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:02:50.15188 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:02:50.15188 0.03121747] 2016-12-01T17:02:50.15200 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:02:50.15210 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:02:50.15221 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:02:50.15232 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:02:50.15367 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:02:50.15463 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:02:50.15492 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:02:57.15609 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:02:57.19458 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.486087097 2016-12-01T17:02:57.19716 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.486087097 2016-12-01T17:02:57.25801 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:02:57.25818 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:02:57.30327 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:02:57.30329 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:02:57.30329 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:02:57.30330 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:02:57.30330 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:02:57.30331 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:02:57.30331 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:02:57.30332 0.03121747] 2016-12-01T17:02:57.30332 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:02:57.30333 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:02:57.30333 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:02:57.30335 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:02:57.30431 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:02:57.30496 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:02:57.30523 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:03:04.30556 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:03:04.30601 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.4857791147 2016-12-01T17:03:04.30767 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.4857791147 2016-12-01T17:03:04.36343 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:03:04.36364 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:03:04.42931 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:03:04.42938 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:03:04.42947 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:03:04.42955 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:03:04.43050 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:03:04.43051 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:03:04.43051 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:03:04.43052 0.03121747] 2016-12-01T17:03:04.43064 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:03:04.43073 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:03:04.43084 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:03:04.43102 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:03:04.43657 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:03:04.43723 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:03:04.43755 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:03:11.43802 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:03:11.45610 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.4907246533 2016-12-01T17:03:11.45657 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.4907246533 2016-12-01T17:03:11.52287 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:03:11.52288 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:03:11.55380 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:03:11.55382 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:03:11.55382 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:03:11.55383 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:03:11.55383 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:03:11.55384 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:03:11.55384 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:03:11.55385 0.03121747] 2016-12-01T17:03:11.55385 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:03:11.55386 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:03:11.55386 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:03:11.55403 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:03:11.56599 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:03:11.57687 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:03:11.58321 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:03:18.57774 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:03:18.63084 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.490407824 2016-12-01T17:03:18.63149 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.490407824 2016-12-01T17:03:18.69759 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:03:18.69761 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:03:18.74305 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:03:18.74315 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:03:18.74323 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:03:18.74470 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:03:18.74471 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:03:18.74471 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:03:18.74472 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:03:18.74472 0.03121747] 2016-12-01T17:03:18.74472 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:03:18.74473 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:03:18.74473 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:03:18.74473 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:03:18.74610 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:03:18.74665 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:03:18.74729 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:03:25.74783 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:03:25.78324 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.4891963665 2016-12-01T17:03:25.78443 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.4891963665 2016-12-01T17:03:25.84589 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:03:25.84604 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:03:25.87782 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:03:25.87794 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:03:25.87805 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:03:25.87812 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:03:25.87869 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:03:25.87870 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:03:25.87870 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:03:25.87871 0.03121747] 2016-12-01T17:03:25.87876 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:03:25.87882 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:03:25.87889 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:03:25.87895 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:03:25.88027 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:03:25.88099 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:03:25.88267 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:03:32.88547 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:03:32.89521 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.4888415371 2016-12-01T17:03:32.90001 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.4888415371 2016-12-01T17:03:32.96023 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:03:32.96391 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:03:33.07982 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:03:33.07983 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:03:33.07983 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:03:33.07984 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:03:33.07984 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:03:33.07985 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:03:33.07985 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:03:33.07986 0.03121747] 2016-12-01T17:03:33.07986 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:03:33.07987 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:03:33.07987 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:03:33.07987 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:03:33.09402 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:03:33.09937 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:03:33.09971 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:03:40.10067 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:03:40.12092 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.4829878371 2016-12-01T17:03:40.12136 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.4829878371 2016-12-01T17:03:40.18813 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:03:40.18815 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:03:40.22210 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:03:40.22212 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:03:40.22213 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:03:40.22213 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:03:40.22324 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:03:40.22325 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:03:40.22326 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:03:40.22327 0.03121747] 2016-12-01T17:03:40.22327 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:03:40.22329 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:03:40.22330 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:03:40.22330 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:03:40.23015 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:03:40.23070 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:03:40.23101 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:03:47.23446 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:03:47.29374 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.4837010086 2016-12-01T17:03:47.29585 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.4837010086 2016-12-01T17:03:47.36354 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:03:47.36356 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:03:47.41222 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:03:47.41224 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:03:47.41225 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:03:47.41324 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:03:47.41326 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:03:47.41326 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:03:47.41327 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:03:47.41327 0.03121747] 2016-12-01T17:03:47.41327 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:03:47.41328 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:03:47.41328 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:03:47.41328 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:03:47.41582 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:03:47.41650 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:03:47.41695 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:03:54.41772 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:03:54.46220 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.4744189766 2016-12-01T17:03:54.46273 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.4744189766 2016-12-01T17:03:54.52578 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:03:54.52580 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:03:54.55351 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:03:54.55353 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:03:54.55354 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:03:54.55354 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:03:54.55494 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:03:54.55495 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:03:54.55496 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:03:54.55497 0.03121747] 2016-12-01T17:03:54.55497 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:03:54.55498 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:03:54.55498 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:03:54.55499 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:03:54.55585 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:03:54.55650 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:03:54.55681 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:04:01.55720 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:04:01.56503 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.4768564654 2016-12-01T17:04:01.56923 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.4768564654 2016-12-01T17:04:01.62873 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:04:01.62884 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:04:01.65407 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:04:01.65410 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:04:01.65410 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:04:01.65411 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:04:01.65486 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:04:01.65487 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:04:01.65487 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:04:01.65488 0.03121747] 2016-12-01T17:04:01.65488 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:04:01.65489 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:04:01.65489 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:04:01.65490 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:04:01.65647 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:04:01.65732 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:04:01.65766 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:04:08.65793 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:04:08.66660 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.4762537432 2016-12-01T17:04:08.66800 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.4762537432 2016-12-01T17:04:08.73390 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:04:08.73392 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:04:08.77972 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:04:08.77974 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:04:08.77975 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:04:08.77975 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:04:08.78030 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:04:08.78031 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:04:08.78031 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:04:08.78032 0.03121747] 2016-12-01T17:04:08.78032 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:04:08.78033 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:04:08.78033 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:04:08.78034 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:04:08.78347 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:04:08.78834 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:04:08.78865 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:04:15.78914 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:04:15.83151 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.4703246937 2016-12-01T17:04:15.84199 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.4703246937 2016-12-01T17:04:15.89487 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:04:15.89489 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:04:15.92579 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:04:15.92591 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:04:15.92602 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:04:15.92613 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:04:15.92703 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:04:15.92704 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:04:15.92705 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:04:15.92706 0.03121747] 2016-12-01T17:04:15.92717 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:04:15.92730 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:04:15.92742 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:04:15.92753 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:04:15.93514 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:04:15.93582 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:04:15.93956 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:04:22.94095 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:04:22.99239 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.4673508469 2016-12-01T17:04:22.99325 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.4673508469 2016-12-01T17:04:23.05401 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:04:23.05418 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:04:23.16856 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:04:23.16861 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:04:23.16864 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:04:23.16874 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:04:23.16957 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:04:23.16958 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:04:23.16958 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:04:23.16959 0.03121747] 2016-12-01T17:04:23.16970 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:04:23.16979 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:04:23.16989 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:04:23.16999 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:04:23.17196 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:04:23.17280 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:04:23.17337 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:04:30.17359 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:04:30.21742 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.460550834 2016-12-01T17:04:30.22168 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.460550834 2016-12-01T17:04:30.28050 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:04:30.28060 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:04:30.31578 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:04:30.31585 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:04:30.31592 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:04:30.31598 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:04:30.31652 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:04:30.31653 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:04:30.31653 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:04:30.31654 0.03121747] 2016-12-01T17:04:30.31660 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:04:30.31665 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:04:30.31672 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:04:30.31678 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:04:30.32593 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:04:30.33421 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:04:30.33470 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:04:37.33504 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:04:37.38013 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.4594531696 2016-12-01T17:04:37.38066 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.4594531696 2016-12-01T17:04:37.44426 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:04:37.44499 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:04:37.47500 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:04:37.47512 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:04:37.47527 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:04:37.47538 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:04:37.47635 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:04:37.47636 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:04:37.47636 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:04:37.47637 0.03121747] 2016-12-01T17:04:37.47648 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:04:37.47666 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:04:37.47677 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:04:37.47687 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:04:37.48177 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:04:37.48509 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:04:37.48534 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:04:44.48711 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:04:44.54044 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.4572570597 2016-12-01T17:04:44.54515 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.4572570597 2016-12-01T17:04:44.60269 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:04:44.60283 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:04:44.63520 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:04:44.63528 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:04:44.63535 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:04:44.63542 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:04:44.63597 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:04:44.63598 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:04:44.63598 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:04:44.63599 0.03121747] 2016-12-01T17:04:44.63605 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:04:44.63610 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:04:44.63617 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:04:44.63623 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:04:44.63914 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:04:44.64186 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:04:44.64218 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:04:51.64239 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:04:51.65065 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.4521705522 2016-12-01T17:04:51.65199 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.4521705522 2016-12-01T17:04:51.71297 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:04:51.71475 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:04:51.75526 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:04:51.75538 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:04:51.75550 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:04:51.75561 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:04:51.75660 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:04:51.75661 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:04:51.75662 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:04:51.75662 0.03121747] 2016-12-01T17:04:51.75674 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:04:51.75684 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:04:51.75695 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:04:51.75706 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:04:51.75954 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:04:51.76374 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:04:51.76406 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:04:58.76526 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:04:58.81027 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.448798171 2016-12-01T17:04:58.81084 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.448798171 2016-12-01T17:04:58.87210 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:04:58.87212 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:04:58.92602 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:04:58.92604 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:04:58.92605 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:04:58.92605 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:04:58.92606 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:04:58.92606 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:04:58.92607 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:04:58.92607 0.03121747] 2016-12-01T17:04:58.92608 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:04:58.92608 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:04:58.92609 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:04:58.92610 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:04:58.93285 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:04:58.93446 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:04:58.93519 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:05:05.93566 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:05:05.98744 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.4429686953 2016-12-01T17:05:05.98959 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.4429686953 2016-12-01T17:05:06.05108 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:05:06.05145 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:05:06.08728 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:05:06.08730 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:05:06.08730 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:05:06.08731 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:05:06.08752 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:05:06.08753 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:05:06.08753 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:05:06.08754 0.03121747] 2016-12-01T17:05:06.08760 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:05:06.08766 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:05:06.08774 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:05:06.08781 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:05:06.09331 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:05:06.09527 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:05:06.09537 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:05:13.09816 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:05:13.15293 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.4527007723 2016-12-01T17:05:13.15728 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.4527007723 2016-12-01T17:05:13.21506 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:05:13.21518 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:05:13.26518 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:05:13.26529 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:05:13.26541 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:05:13.26552 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:05:13.26647 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:05:13.26648 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:05:13.26648 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:05:13.26649 0.03121747] 2016-12-01T17:05:13.26661 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:05:13.26671 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:05:13.26682 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:05:13.26693 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:05:13.28630 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:05:13.28783 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:05:13.28832 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:05:20.28866 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:05:20.32166 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.4463374869 2016-12-01T17:05:20.32479 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.4463374869 2016-12-01T17:05:20.38602 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:05:20.38605 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:05:20.41072 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:05:20.41128 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:05:20.41129 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:05:20.41130 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:05:20.41203 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:05:20.41204 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:05:20.41204 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:05:20.41205 0.03121747] 2016-12-01T17:05:20.41217 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:05:20.41227 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:05:20.41238 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:05:20.41249 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:05:20.41402 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:05:20.41456 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:05:20.41534 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:05:27.41824 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:05:27.43215 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.4422499663 2016-12-01T17:05:27.43591 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.4422499663 2016-12-01T17:05:27.49214 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:05:27.49216 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:05:27.51872 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:05:27.51875 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:05:27.51875 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:05:27.51876 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:05:27.51876 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:05:27.51877 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:05:27.51877 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:05:27.51878 0.03121747] 2016-12-01T17:05:27.51878 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:05:27.51879 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:05:27.51879 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:05:27.51881 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:05:27.52595 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:05:27.52662 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:05:27.52692 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:05:34.52716 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:05:34.53676 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.4446171114 2016-12-01T17:05:34.53730 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.4446171114 2016-12-01T17:05:34.59950 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:05:34.59965 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:05:34.62631 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:05:34.62637 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:05:34.62644 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:05:34.62650 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:05:34.62718 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:05:34.62721 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:05:34.62722 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:05:34.62722 0.03121747] 2016-12-01T17:05:34.62732 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:05:34.62741 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:05:34.62749 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:05:34.62756 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:05:34.62899 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:05:34.63543 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:05:34.63708 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:05:41.63648 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:05:41.69155 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.4428284772 2016-12-01T17:05:41.69555 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.4428284772 2016-12-01T17:05:41.76163 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:05:41.76166 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:05:41.78710 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:05:41.78712 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:05:41.78713 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:05:41.78714 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:05:41.78714 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:05:41.78715 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:05:41.78715 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:05:41.78716 0.03121747] 2016-12-01T17:05:41.78717 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:05:41.78735 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:05:41.78737 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:05:41.78737 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:05:41.79368 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:05:41.80074 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:05:41.80121 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:05:48.80146 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:05:48.85225 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.4469693164 2016-12-01T17:05:48.85286 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.4469693164 2016-12-01T17:05:48.91600 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:05:48.91602 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:05:48.95817 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:05:48.95820 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:05:48.95820 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:05:48.95820 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:05:48.95917 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:05:48.95918 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:05:48.95919 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:05:48.95921 0.03121747] 2016-12-01T17:05:48.95922 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:05:48.95922 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:05:48.95923 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:05:48.95923 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:05:48.97464 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:05:48.97541 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:05:48.97809 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:05:55.97683 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:05:56.01725 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.4448210563 2016-12-01T17:05:56.02136 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.4448210563 2016-12-01T17:05:56.08026 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:05:56.08029 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:05:56.12070 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:05:56.12072 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:05:56.12073 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:05:56.12073 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:05:56.12074 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:05:56.12075 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:05:56.12076 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:05:56.12076 0.03121747] 2016-12-01T17:05:56.12077 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:05:56.12077 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:05:56.12078 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:05:56.12078 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:05:56.12608 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:05:56.12748 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:05:56.12804 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:06:03.12818 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:06:03.18884 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.4426145323 2016-12-01T17:06:03.18983 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.4426145323 2016-12-01T17:06:03.24963 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:06:03.24995 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:06:03.53787 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:06:03.53790 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:06:03.53790 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:06:03.53790 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:06:03.53791 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:06:03.53791 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:06:03.53792 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:06:03.53792 0.03121747] 2016-12-01T17:06:03.53792 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:06:03.53793 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:06:03.53793 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:06:03.53793 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:06:03.54134 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:06:03.54199 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:06:03.54231 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:06:10.54247 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:06:10.54560 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.4492748031 2016-12-01T17:06:10.54734 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.4492748031 2016-12-01T17:06:10.61128 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:06:10.61130 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:06:10.63336 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:06:10.63348 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:06:10.63360 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:06:10.63370 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:06:10.63459 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:06:10.63460 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:06:10.63461 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:06:10.63461 0.03121747] 2016-12-01T17:06:10.63468 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:06:10.63477 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:06:10.63487 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:06:10.63497 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:06:10.64304 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:06:10.64701 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:06:10.64702 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:06:17.64621 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:06:17.65782 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.4614300696 2016-12-01T17:06:17.66061 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.4614300696 2016-12-01T17:06:17.72088 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:06:17.72090 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:06:17.77076 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:06:17.77084 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:06:17.77093 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:06:17.77102 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:06:17.77239 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:06:17.77240 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:06:17.77241 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:06:17.77241 0.03121747] 2016-12-01T17:06:17.77242 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:06:17.77242 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:06:17.77243 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:06:17.77243 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:06:17.77336 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:06:17.77400 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:06:17.77431 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:06:24.77591 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:06:24.83431 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.4592599776 2016-12-01T17:06:24.83813 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.4592599776 2016-12-01T17:06:24.89692 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:06:24.89719 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:06:24.93574 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:06:24.93726 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:06:24.93727 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:06:24.93728 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:06:24.93728 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:06:24.93729 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:06:24.93729 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:06:24.93730 0.03121747] 2016-12-01T17:06:24.93730 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:06:24.93731 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:06:24.93731 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:06:24.93732 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:06:24.93818 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:06:24.94237 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:06:24.94283 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:06:31.94317 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:06:31.99789 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.4579228762 2016-12-01T17:06:31.99955 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.4579228762 2016-12-01T17:06:32.06144 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:06:32.06146 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:06:32.10336 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:06:32.10527 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:06:32.10528 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:06:32.10528 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:06:32.10529 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:06:32.10529 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:06:32.10530 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:06:32.10530 0.03121747] 2016-12-01T17:06:32.10530 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:06:32.10531 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:06:32.10531 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:06:32.10532 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:06:32.11010 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:06:32.11075 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:06:32.11363 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:06:39.11416 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:06:39.11806 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.4612261762 2016-12-01T17:06:39.11816 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.4612261762 2016-12-01T17:06:39.17474 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:06:39.17485 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:06:39.20116 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:06:39.20128 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:06:39.20140 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:06:39.20150 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:06:39.20235 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:06:39.20236 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:06:39.20237 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:06:39.20237 0.03121747] 2016-12-01T17:06:39.20248 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:06:39.20257 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:06:39.20267 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:06:39.20277 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:06:39.20380 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:06:39.20437 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:06:39.20467 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:06:46.20492 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:06:46.21813 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.4596626982 2016-12-01T17:06:46.22484 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.4596626982 2016-12-01T17:06:46.28227 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:06:46.28229 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:06:46.31193 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:06:46.31196 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:06:46.31196 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:06:46.31197 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:06:46.31320 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:06:46.31321 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:06:46.31322 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:06:46.31322 0.03121747] 2016-12-01T17:06:46.31323 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:06:46.31323 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:06:46.31324 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:06:46.31324 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:06:46.31443 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:06:46.31501 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:06:46.31529 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:06:53.31551 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:06:53.32210 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.4666607158 2016-12-01T17:06:53.32797 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.4666607158 2016-12-01T17:06:53.38549 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:06:53.38551 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:06:53.41795 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:06:53.41797 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:06:53.41798 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:06:53.41798 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:06:53.41798 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:06:53.41799 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:06:53.41800 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:06:53.41800 0.03121747] 2016-12-01T17:06:53.41800 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:06:53.41801 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:06:53.41801 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:06:53.41802 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:06:53.41887 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:06:53.42562 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:06:53.42619 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:07:00.42751 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:07:00.48492 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.469481076 2016-12-01T17:07:00.48569 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.469481076 2016-12-01T17:07:00.54797 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:07:00.54818 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:07:00.59802 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:07:00.59813 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:07:00.59824 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:07:00.59835 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:07:00.59930 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:07:00.59931 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:07:00.59931 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:07:00.59932 0.03121747] 2016-12-01T17:07:00.59944 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:07:00.59953 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:07:00.59965 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:07:00.59975 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:07:00.60642 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:07:00.60958 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:07:00.60996 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:07:07.61005 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:07:07.63777 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.4666433212 2016-12-01T17:07:07.63832 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.4666433212 2016-12-01T17:07:07.70129 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:07:07.70146 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:07:07.73075 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:07:07.73077 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:07:07.73078 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:07:07.73078 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:07:07.73079 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:07:07.73079 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:07:07.73080 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:07:07.73080 0.03121747] 2016-12-01T17:07:07.73081 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:07:07.73081 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:07:07.73082 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:07:07.73082 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:07:07.73465 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:07:07.73505 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:07:07.73532 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:07:14.73922 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:07:14.74103 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.4650077917 2016-12-01T17:07:14.74168 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.4650077917 2016-12-01T17:07:14.79996 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:07:14.80026 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:07:14.82594 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:07:14.82597 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:07:14.82597 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:07:14.82598 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:07:14.82599 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:07:14.82599 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:07:14.82600 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:07:14.82600 0.03121747] 2016-12-01T17:07:14.82601 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:07:14.82601 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:07:14.82602 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:07:14.82602 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:07:14.82938 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:07:14.83356 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:07:14.83406 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:07:21.83440 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:07:21.84015 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.4637987592 2016-12-01T17:07:21.84077 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.4637987592 2016-12-01T17:07:21.90646 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:07:21.90648 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:07:21.94453 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:07:21.94458 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:07:21.94467 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:07:21.94542 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:07:21.94621 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:07:21.94623 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:07:21.94624 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:07:21.94624 0.03121747] 2016-12-01T17:07:21.94625 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:07:21.94625 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:07:21.94625 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:07:21.94626 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:07:21.95264 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:07:21.95919 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:07:21.95968 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:07:28.96002 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:07:29.01113 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.4676522147 2016-12-01T17:07:29.01754 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.4676522147 2016-12-01T17:07:29.07318 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:07:29.07321 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:07:29.11230 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:07:29.11236 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:07:29.11249 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:07:29.11408 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:07:29.11409 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:07:29.11410 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:07:29.11411 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:07:29.11411 0.03121747] 2016-12-01T17:07:29.11412 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:07:29.11413 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:07:29.11414 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:07:29.11414 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:07:29.12105 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:07:29.12174 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:07:29.12207 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:07:36.12237 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:07:36.17445 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.459979624 2016-12-01T17:07:36.17744 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.459979624 2016-12-01T17:07:36.23727 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:07:36.23730 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:07:36.27676 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:07:36.27678 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:07:36.27678 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:07:36.27679 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:07:36.27679 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:07:36.27680 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:07:36.27680 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:07:36.27681 0.03121747] 2016-12-01T17:07:36.27681 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:07:36.27682 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:07:36.27682 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:07:36.27683 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:07:36.27911 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:07:36.28082 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:07:36.28130 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:07:43.28623 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:07:43.34340 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.4607315629 2016-12-01T17:07:43.34521 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.4607315629 2016-12-01T17:07:43.40676 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:07:43.40678 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:07:43.43134 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:07:43.43263 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:07:43.43264 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:07:43.43265 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:07:43.43265 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:07:43.43265 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:07:43.43267 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:07:43.43267 0.03121747] 2016-12-01T17:07:43.43268 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:07:43.43268 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:07:43.43268 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:07:43.43269 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:07:43.43387 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:07:43.43493 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:07:43.43527 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:07:50.43562 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:07:50.44634 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.450804411 2016-12-01T17:07:50.45059 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.450804411 2016-12-01T17:07:50.50718 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:07:50.50731 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:07:50.54748 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:07:50.54750 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:07:50.54751 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:07:50.54751 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:07:50.54794 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:07:50.54795 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:07:50.54796 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:07:50.54797 0.03121747] 2016-12-01T17:07:50.54797 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:07:50.54798 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:07:50.54798 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:07:50.54798 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:07:50.54891 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:07:50.54942 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:07:50.55085 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:07:57.55142 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:07:57.55925 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.4471748883 2016-12-01T17:07:57.56055 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.4471748883 2016-12-01T17:07:57.62265 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:07:57.62280 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:07:57.68979 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:07:57.68981 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:07:57.68981 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:07:57.68981 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:07:57.68983 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:07:57.68983 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:07:57.68984 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:07:57.68984 0.03121747] 2016-12-01T17:07:57.68985 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:07:57.68985 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:07:57.68985 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:07:57.68986 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:07:57.69469 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:07:57.69564 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:07:57.69595 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:08:04.69621 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:08:04.71960 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.4330360424 2016-12-01T17:08:04.72022 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.4330360424 2016-12-01T17:08:04.78310 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:08:04.78313 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:08:04.81311 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:08:04.81471 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:08:04.81472 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:08:04.81473 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:08:04.81473 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:08:04.81474 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:08:04.81474 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:08:04.81475 0.03121747] 2016-12-01T17:08:04.81476 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:08:04.81476 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:08:04.81477 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:08:04.81477 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:08:04.81690 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:08:04.81749 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:08:04.81788 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:08:11.81822 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:08:11.82196 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.4150452871 2016-12-01T17:08:11.82260 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.4150452871 2016-12-01T17:08:11.88523 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:08:11.88525 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:08:11.93429 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:08:11.93432 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:08:11.93433 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:08:11.93433 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:08:11.93434 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:08:11.93434 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:08:11.93435 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:08:11.93435 0.03121747] 2016-12-01T17:08:11.93436 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:08:11.93436 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:08:11.93437 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:08:11.93437 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:08:11.93651 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:08:11.93717 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:08:11.93746 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:08:18.94102 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:08:18.98692 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.3924224893 2016-12-01T17:08:18.98850 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3924224893 2016-12-01T17:08:19.04862 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:08:19.04873 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:08:19.09785 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:08:19.09948 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:08:19.09949 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:08:19.09950 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:08:19.09950 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:08:19.09951 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:08:19.09951 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:08:19.09952 0.03121747] 2016-12-01T17:08:19.09953 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:08:19.09953 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:08:19.09954 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:08:19.09954 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:08:19.10170 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:08:19.10236 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:08:19.10297 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:08:26.10277 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:08:26.14991 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.3710933871 2016-12-01T17:08:26.15067 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3710933871 2016-12-01T17:08:26.21233 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:08:26.21238 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:08:26.23849 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:08:26.23851 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:08:26.24025 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:08:26.24026 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:08:26.24026 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:08:26.24027 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:08:26.24028 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:08:26.24028 0.03121747] 2016-12-01T17:08:26.24029 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:08:26.24029 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:08:26.24030 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:08:26.24030 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:08:26.25207 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:08:26.25765 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:08:26.25778 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:08:33.25819 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:08:33.31601 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.3395271622 2016-12-01T17:08:33.32004 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3395271622 2016-12-01T17:08:33.38176 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:08:33.38192 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:08:33.41255 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:08:33.41257 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:08:33.41258 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:08:33.41258 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:08:33.41259 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:08:33.41259 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:08:33.41260 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:08:33.41260 0.03121747] 2016-12-01T17:08:33.41261 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:08:33.41261 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:08:33.41262 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:08:33.41262 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:08:33.41503 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:08:33.42099 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:08:33.42131 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:08:40.42176 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:08:40.48120 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.3056660461 2016-12-01T17:08:40.48194 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3056660461 2016-12-01T17:08:40.54154 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:08:40.54170 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:08:40.58515 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:08:40.58517 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:08:40.58518 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:08:40.58518 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:08:40.58519 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:08:40.58519 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:08:40.58520 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:08:40.58520 0.03121747] 2016-12-01T17:08:40.58521 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:08:40.58521 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:08:40.58521 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:08:40.58522 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:08:40.58621 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:08:40.58688 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:08:40.58700 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:08:47.58751 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:08:47.63427 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.268145232 2016-12-01T17:08:47.63470 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.268145232 2016-12-01T17:08:47.69784 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:08:47.69792 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:08:47.80237 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:08:47.80238 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:08:47.80239 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:08:47.80239 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:08:47.80239 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:08:47.80240 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:08:47.80240 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:08:47.80240 0.03121747] 2016-12-01T17:08:47.80241 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:08:47.80241 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:08:47.80241 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:08:47.80242 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:08:47.80527 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:08:47.80890 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:08:47.80922 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:08:54.81348 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:08:54.85893 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.2180311589 2016-12-01T17:08:54.86057 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.2180311589 2016-12-01T17:08:54.92293 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:08:54.92295 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:08:54.95142 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:08:54.95154 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:08:54.95165 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:08:54.95176 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:08:54.95272 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:08:54.95273 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:08:54.95273 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:08:54.95273 0.03121747] 2016-12-01T17:08:54.95282 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:08:54.95292 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:08:54.95302 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:08:54.95313 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:08:54.95426 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:08:54.95491 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:08:54.95531 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:09:01.95552 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:09:01.96596 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.1680750009 2016-12-01T17:09:01.96701 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.1680750009 2016-12-01T17:09:02.03301 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:09:02.03322 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:09:02.06464 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:09:02.06476 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:09:02.06488 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:09:02.06499 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:09:02.06591 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:09:02.06592 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:09:02.06593 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:09:02.06593 0.03121747] 2016-12-01T17:09:02.06605 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:09:02.06615 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:09:02.06625 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:09:02.06636 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:09:02.07349 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:09:02.07913 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:09:02.07959 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:09:09.08046 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:09:09.13805 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.1230946519 2016-12-01T17:09:09.13923 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.1230946519 2016-12-01T17:09:09.20350 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:09:09.20371 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:09:09.24796 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:09:09.24803 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:09:09.24813 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:09:09.24821 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:09:09.24880 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:09:09.24881 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:09:09.24881 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:09:09.24882 0.03121747] 2016-12-01T17:09:09.24893 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:09:09.24899 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:09:09.24908 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:09:09.24916 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:09:09.25113 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:09:09.25179 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:09:09.25210 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:09:16.25301 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:09:16.30149 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.0715305527 2016-12-01T17:09:16.30202 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.0715305527 2016-12-01T17:09:16.36889 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:09:16.36902 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:09:16.40050 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:09:16.40053 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:09:16.40053 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:09:16.40054 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:09:16.40175 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:09:16.40176 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:09:16.40177 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:09:16.40177 0.03121747] 2016-12-01T17:09:16.40178 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:09:16.40178 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:09:16.40179 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:09:16.40179 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:09:16.40769 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:09:16.41413 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:09:16.41581 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:09:23.41623 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:09:23.46379 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.0181229426 2016-12-01T17:09:23.46661 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.0181229426 2016-12-01T17:09:23.52712 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:09:23.52714 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:09:23.56055 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:09:23.56057 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:09:23.56058 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:09:23.56058 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:09:23.56120 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:09:23.56121 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:09:23.56121 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:09:23.56122 0.03121747] 2016-12-01T17:09:23.56122 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:09:23.56123 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:09:23.56123 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:09:23.56124 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:09:23.57369 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:09:23.57825 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:09:23.57848 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:09:30.57885 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:09:30.62503 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 58.9495980322 2016-12-01T17:09:30.62560 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 58.9495980322 2016-12-01T17:09:30.68614 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:09:30.68623 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:09:30.71048 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:09:30.71057 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:09:30.71066 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:09:30.71075 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:09:30.71168 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:09:30.71169 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:09:30.71169 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:09:30.71170 0.03121747] 2016-12-01T17:09:30.71177 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:09:30.71185 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:09:30.71193 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:09:30.71201 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:09:30.71341 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:09:30.71643 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:09:30.71667 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:09:37.71921 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:09:37.77946 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 58.8971557214 2016-12-01T17:09:37.78347 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 58.8971557214 2016-12-01T17:09:37.84286 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:09:37.84288 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:09:37.86969 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:09:37.86975 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:09:37.86982 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:09:37.86992 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:09:37.87088 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:09:37.87090 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:09:37.87090 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:09:37.87091 0.03121747] 2016-12-01T17:09:37.87102 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:09:37.87111 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:09:37.87122 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:09:37.87133 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:09:37.87365 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:09:37.88204 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:09:37.88227 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:09:44.88348 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:09:44.93476 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 58.8390587086 2016-12-01T17:09:44.93814 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 58.8390587086 2016-12-01T17:09:45.00302 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:09:45.00318 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:09:45.04235 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:09:45.04247 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:09:45.04259 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:09:45.04270 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:09:45.04371 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:09:45.04374 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:09:45.04374 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:09:45.04375 0.03121747] 2016-12-01T17:09:45.04386 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:09:45.04400 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:09:45.04404 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:09:45.04412 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:09:45.04998 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:09:45.05065 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:09:45.05117 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:09:52.05210 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:09:52.10816 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 58.7757168663 2016-12-01T17:09:52.11008 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 58.7757168663 2016-12-01T17:09:52.17204 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:09:52.17206 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:09:52.19974 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:09:52.19976 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:09:52.19977 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:09:52.19978 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:09:52.19978 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:09:52.19979 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:09:52.19979 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:09:52.19979 0.03121747] 2016-12-01T17:09:52.19980 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:09:52.19980 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:09:52.19981 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:09:52.19981 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:09:52.20372 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:09:52.20528 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:09:52.20559 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:09:59.20656 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:09:59.21911 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 58.7417029502 2016-12-01T17:09:59.22020 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 58.7417029502 2016-12-01T17:09:59.28304 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:09:59.28306 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:09:59.32198 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:09:59.32364 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:09:59.32366 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:09:59.32367 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:09:59.32368 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:09:59.32368 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:09:59.32369 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:09:59.32369 0.03121747] 2016-12-01T17:09:59.32370 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:09:59.32370 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:09:59.32371 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:09:59.32371 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:09:59.32982 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:09:59.33427 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:09:59.33452 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:10:06.33496 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:10:06.35752 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 58.7723650887 2016-12-01T17:10:06.36357 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 58.7723650887 2016-12-01T17:10:06.41922 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:10:06.41924 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:10:06.45532 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:10:06.45534 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:10:06.45535 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:10:06.45536 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:10:06.45536 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:10:06.45537 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:10:06.45537 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:10:06.45537 0.03121747] 2016-12-01T17:10:06.45538 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:10:06.45538 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:10:06.45539 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:10:06.45539 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:10:06.46108 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:10:06.46239 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:10:06.46283 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:10:13.46303 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:10:13.48924 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 58.8042952127 2016-12-01T17:10:13.49215 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 58.8042952127 2016-12-01T17:10:13.55494 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:10:13.55495 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:10:13.57767 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:10:13.57770 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:10:13.57781 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:10:13.57790 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:10:13.57875 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:10:13.57876 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:10:13.57876 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:10:13.57877 0.03121747] 2016-12-01T17:10:13.57884 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:10:13.57891 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:10:13.57898 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:10:13.57906 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:10:13.58018 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:10:13.58149 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:10:13.58184 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:10:20.58208 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:10:20.59125 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 58.8478769044 2016-12-01T17:10:20.59214 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 58.8478769044 2016-12-01T17:10:20.65496 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:10:20.65514 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:10:20.68401 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:10:20.68407 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:10:20.68414 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:10:20.68421 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:10:20.68475 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:10:20.68476 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:10:20.68476 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:10:20.68477 0.03121747] 2016-12-01T17:10:20.68484 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:10:20.68489 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:10:20.68496 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:10:20.68502 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:10:20.69926 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:10:20.70917 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:10:20.70969 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:10:27.70995 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:10:27.75403 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 58.8966255811 2016-12-01T17:10:27.75447 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 58.8966255811 2016-12-01T17:10:27.81357 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:10:27.81369 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:10:28.14454 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:10:28.14465 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:10:28.14477 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:10:28.14488 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:10:28.14580 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:10:28.14581 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:10:28.14582 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:10:28.14582 0.03121747] 2016-12-01T17:10:28.14594 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:10:28.14603 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:10:28.14614 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:10:28.14624 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:10:28.16040 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:10:28.16854 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:10:28.16904 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:10:35.17141 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:10:35.22922 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 58.9404904978 2016-12-01T17:10:35.23097 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 58.9404904978 2016-12-01T17:10:35.29191 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:10:35.29206 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:10:35.32417 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:10:35.32428 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:10:35.32439 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:10:35.32450 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:10:35.32538 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:10:35.32539 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:10:35.32540 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:10:35.32540 0.03121747] 2016-12-01T17:10:35.32551 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:10:35.32561 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:10:35.32571 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:10:35.32581 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:10:35.32700 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:10:35.32756 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:10:35.32787 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:10:42.32952 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:10:42.33042 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 58.9793753808 2016-12-01T17:10:42.33234 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 58.9793753808 2016-12-01T17:10:42.40230 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:10:42.40232 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:10:42.42954 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:10:42.42956 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:10:42.42957 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:10:42.42957 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:10:42.43089 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:10:42.43090 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:10:42.43091 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:10:42.43091 0.03121747] 2016-12-01T17:10:42.43092 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:10:42.43093 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:10:42.43093 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:10:42.43094 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:10:42.43228 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:10:42.43351 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:10:42.43442 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:10:49.43429 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:10:49.43566 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.0163784574 2016-12-01T17:10:49.43903 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.0163784574 2016-12-01T17:10:49.49914 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:10:49.50039 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:10:49.53789 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:10:49.53790 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:10:49.53791 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:10:49.53792 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:10:49.53792 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:10:49.53793 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:10:49.53793 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:10:49.53794 0.03121747] 2016-12-01T17:10:49.53794 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:10:49.53795 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:10:49.53795 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:10:49.53796 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:10:49.54353 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:10:49.54573 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:10:49.54668 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:10:56.54684 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:10:56.60219 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.0380203579 2016-12-01T17:10:56.60420 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.0380203579 2016-12-01T17:10:56.66573 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:10:56.66575 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:10:56.69707 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:10:56.69709 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:10:56.69709 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:10:56.69710 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:10:56.69710 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:10:56.69711 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:10:56.69711 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:10:56.69712 0.03121747] 2016-12-01T17:10:56.69713 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:10:56.69750 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:10:56.69751 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:10:56.69751 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:10:56.71261 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:10:56.71624 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:10:56.71668 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:11:03.71707 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:11:03.76642 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 58.9032901963 2016-12-01T17:11:03.76694 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 58.9032901963 2016-12-01T17:11:03.82864 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:11:03.82885 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:11:03.85550 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:11:03.85562 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:11:03.85574 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:11:03.85584 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:11:03.85676 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:11:03.85677 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:11:03.85678 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:11:03.85679 0.03121747] 2016-12-01T17:11:03.85691 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:11:03.85701 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:11:03.85711 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:11:03.85722 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:11:03.86651 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:11:03.87589 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:11:03.87650 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:11:10.87743 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:11:10.93015 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 58.7473027236 2016-12-01T17:11:10.93137 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 58.7473027236 2016-12-01T17:11:10.99829 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:11:10.99831 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:11:11.02784 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:11:11.02786 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:11:11.02787 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:11:11.02787 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:11:11.02788 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:11:11.02788 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:11:11.02789 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:11:11.02789 0.03121747] 2016-12-01T17:11:11.02790 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:11:11.02790 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:11:11.02792 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:11:11.02793 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:11:11.03645 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:11:11.03907 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:11:11.03933 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:11:18.04137 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:11:18.09696 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 58.6150224451 2016-12-01T17:11:18.09797 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 58.6150224451 2016-12-01T17:11:18.16740 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:11:18.16774 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:11:18.20779 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:11:18.20782 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:11:18.20784 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:11:18.20785 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:11:18.20785 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:11:18.20786 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:11:18.20786 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:11:18.20787 0.03121747] 2016-12-01T17:11:18.20787 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:11:18.20788 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:11:18.20789 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:11:18.20790 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:11:18.21466 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:11:18.21820 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:11:18.21821 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:11:25.21643 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:11:25.26276 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 58.7245249577 2016-12-01T17:11:25.26374 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 58.7245249577 2016-12-01T17:11:25.32722 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:11:25.32725 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:11:25.35163 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:11:25.35171 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:11:25.35180 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:11:25.35189 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:11:25.35614 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:11:25.35616 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:11:25.35617 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:11:25.35617 0.03121747] 2016-12-01T17:11:25.35618 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:11:25.35618 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:11:25.35619 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:11:25.35619 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:11:25.36147 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:11:25.36259 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:11:25.36291 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:11:32.36343 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:11:32.42254 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 58.8182985499 2016-12-01T17:11:32.42316 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 58.8182985499 2016-12-01T17:11:32.48715 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:11:32.48736 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:11:32.51783 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:11:32.51795 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:11:32.51806 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:11:32.51818 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:11:32.51911 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:11:32.51912 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:11:32.51915 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:11:32.51915 0.03121747] 2016-12-01T17:11:32.51928 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:11:32.51938 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:11:32.51949 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:11:32.51961 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:11:32.52923 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:11:32.53600 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:11:32.53635 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:11:39.53656 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:11:39.59076 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 58.8998701106 2016-12-01T17:11:39.59745 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 58.8998701106 2016-12-01T17:11:39.65528 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:11:39.65549 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:11:39.68138 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:11:39.68140 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:11:39.68141 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:11:39.68142 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:11:39.68195 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:11:39.68197 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:11:39.68197 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:11:39.68198 0.03121747] 2016-12-01T17:11:39.68210 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:11:39.68219 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:11:39.68231 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:11:39.68242 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:11:39.68722 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:11:39.69304 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:11:39.69339 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:11:46.69390 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:11:46.70004 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 58.9731927056 2016-12-01T17:11:46.70173 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 58.9731927056 2016-12-01T17:11:46.76972 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:11:46.76975 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:11:46.78973 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:11:46.78980 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:11:46.78989 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:11:46.79141 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:11:46.79144 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:11:46.79144 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:11:46.79145 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:11:46.79145 0.03121747] 2016-12-01T17:11:46.79146 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:11:46.79146 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:11:46.79147 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:11:46.79147 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:11:46.79232 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:11:46.79295 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:11:46.79341 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:11:53.79377 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:11:53.80701 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.0535944128 2016-12-01T17:11:53.80895 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.0535944128 2016-12-01T17:11:53.87082 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:11:53.87084 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:11:53.90003 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:11:53.90004 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:11:53.90005 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:11:53.90006 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:11:53.90006 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:11:53.90007 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:11:53.90007 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:11:53.90008 0.03121747] 2016-12-01T17:11:53.90008 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:11:53.90009 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:11:53.90009 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:11:53.90010 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:11:53.91409 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:11:53.92369 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:11:53.92417 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:12:00.92451 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:12:00.97178 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.1208992094 2016-12-01T17:12:00.97180 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.1208992094 2016-12-01T17:12:01.03364 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:12:01.03380 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:12:01.07070 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:12:01.07073 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:12:01.07074 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:12:01.07075 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:12:01.07163 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:12:01.07164 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:12:01.07165 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:12:01.07165 0.03121747] 2016-12-01T17:12:01.07165 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:12:01.07166 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:12:01.07166 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:12:01.07167 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:12:01.08084 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:12:01.08309 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:12:01.08326 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:12:08.08346 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:12:08.13715 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.1868028111 2016-12-01T17:12:08.13791 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.1868028111 2016-12-01T17:12:08.20006 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:12:08.20017 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:12:08.25074 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:12:08.25081 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:12:08.25090 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:12:08.25097 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:12:08.25198 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:12:08.25199 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:12:08.25199 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:12:08.25200 0.03121747] 2016-12-01T17:12:08.25204 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:12:08.25209 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:12:08.25216 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:12:08.25223 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:12:08.25869 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:12:08.25953 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:12:08.26000 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:12:15.26451 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:12:15.29442 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.2425788553 2016-12-01T17:12:15.29505 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.2425788553 2016-12-01T17:12:15.35923 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:12:15.35926 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:12:15.37994 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:12:15.37996 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:12:15.37997 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:12:15.37997 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:12:15.37998 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:12:15.37998 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:12:15.37999 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:12:15.37999 0.03121747] 2016-12-01T17:12:15.38000 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:12:15.38000 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:12:15.38001 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:12:15.38001 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:12:15.38417 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:12:15.38483 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:12:15.38516 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:12:22.38563 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:12:22.40565 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.2981819678 2016-12-01T17:12:22.40804 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.2981819678 2016-12-01T17:12:22.46905 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:12:22.46920 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:12:22.49434 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:12:22.49436 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:12:22.49436 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:12:22.49437 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:12:22.49528 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:12:22.49529 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:12:22.49529 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:12:22.49530 0.03121747] 2016-12-01T17:12:22.49530 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:12:22.49531 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:12:22.49531 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:12:22.49532 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:12:22.50344 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:12:22.50418 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:12:22.50523 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:12:29.50552 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:12:29.51376 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.3438956476 2016-12-01T17:12:29.51419 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3438956476 2016-12-01T17:12:29.57812 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:12:29.57841 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:12:29.62251 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:12:29.62253 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:12:29.62253 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:12:29.62254 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:12:29.62254 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:12:29.62254 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:12:29.62255 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:12:29.62255 0.03121747] 2016-12-01T17:12:29.62256 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:12:29.62256 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:12:29.62257 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:12:29.62257 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:12:29.62403 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:12:29.62738 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:12:29.62796 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:12:36.62983 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:12:36.68700 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.3901285937 2016-12-01T17:12:36.68769 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3901285937 2016-12-01T17:12:36.74795 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:12:36.74816 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:12:36.78215 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:12:36.78221 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:12:36.78228 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:12:36.78235 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:12:36.78290 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:12:36.78291 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:12:36.78292 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:12:36.78292 0.03121747] 2016-12-01T17:12:36.78298 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:12:36.78303 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:12:36.78310 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:12:36.78317 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:12:36.78780 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:12:36.79715 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:12:36.79741 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:12:43.79758 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:12:43.84434 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.4267721553 2016-12-01T17:12:43.84507 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.4267721553 2016-12-01T17:12:43.90604 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:12:43.90616 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:12:43.93201 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:12:43.93202 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:12:43.93202 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:12:43.93203 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:12:43.93203 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:12:43.93204 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:12:43.93204 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:12:43.93204 0.03121747] 2016-12-01T17:12:43.93205 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:12:43.93205 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:12:43.93205 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:12:43.93205 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:12:43.93284 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:12:43.93343 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:12:43.93366 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:12:50.93398 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:12:50.95177 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.4572931861 2016-12-01T17:12:50.95478 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.4572931861 2016-12-01T17:12:51.01508 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:12:51.01511 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:12:51.07391 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:12:51.07393 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:12:51.07394 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:12:51.07395 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:12:51.07395 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:12:51.07395 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:12:51.07396 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:12:51.07396 0.03121747] 2016-12-01T17:12:51.07397 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:12:51.07397 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:12:51.07398 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:12:51.07398 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:12:51.07952 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:12:51.08178 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:12:51.08194 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:12:58.08235 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:12:58.12426 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.494893717 2016-12-01T17:12:58.12535 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.494893717 2016-12-01T17:12:58.18634 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:12:58.18646 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:12:58.22307 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:12:58.22312 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:12:58.22457 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:12:58.22458 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:12:58.22459 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:12:58.22459 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:12:58.22460 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:12:58.22460 0.03121747] 2016-12-01T17:12:58.22461 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:12:58.22461 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:12:58.22462 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:12:58.22462 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:12:58.22601 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:12:58.22662 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:12:58.22690 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:13:05.22775 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:13:05.23357 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.5181874137 2016-12-01T17:13:05.23758 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.5181874137 2016-12-01T17:13:05.30056 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:13:05.30079 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:13:05.33308 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:13:05.33310 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:13:05.33310 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:13:05.33311 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:13:05.33384 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:13:05.33386 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:13:05.33386 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:13:05.33387 0.03121747] 2016-12-01T17:13:05.33387 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:13:05.33388 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:13:05.33388 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:13:05.33389 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:13:05.33661 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:13:05.33726 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:13:05.33757 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:13:12.33912 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:13:12.34305 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.5465449355 2016-12-01T17:13:12.34416 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.5465449355 2016-12-01T17:13:12.40557 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:13:12.40559 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:13:12.43978 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:13:12.43980 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:13:12.43981 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:13:12.43982 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:13:12.43983 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:13:12.43984 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:13:12.43984 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:13:12.43986 0.03121747] 2016-12-01T17:13:12.43986 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:13:12.43987 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:13:12.43987 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:13:12.43988 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:13:12.44135 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:13:12.44185 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:13:12.44653 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:13:19.44338 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:13:19.44699 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.5674961189 2016-12-01T17:13:19.44799 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.5674961189 2016-12-01T17:13:19.50821 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:13:19.50824 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:13:19.53734 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:13:19.53746 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:13:19.53757 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:13:19.53768 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:13:19.53845 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:13:19.53846 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:13:19.53846 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:13:19.53847 0.03121747] 2016-12-01T17:13:19.53853 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:13:19.53859 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:13:19.53865 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:13:19.53871 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:13:19.53963 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:13:19.54015 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:13:19.54037 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:13:26.54381 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:13:26.60097 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.5814661021 2016-12-01T17:13:26.60132 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.5814661021 2016-12-01T17:13:26.66787 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:13:26.66805 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:13:26.69226 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:13:26.69238 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:13:26.69250 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:13:26.69262 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:13:26.69570 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:13:26.69571 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:13:26.69572 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:13:26.69572 0.03121747] 2016-12-01T17:13:26.69584 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:13:26.69594 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:13:26.69604 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:13:26.69615 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:13:26.69716 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:13:26.69966 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:13:26.70378 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:13:33.70016 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:13:33.76077 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6042507939 2016-12-01T17:13:33.76355 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6042507939 2016-12-01T17:13:33.82199 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:13:33.82202 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:13:33.84924 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:13:33.84926 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:13:33.84927 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:13:33.84928 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:13:33.85060 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:13:33.85062 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:13:33.85063 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:13:33.85064 0.03121747] 2016-12-01T17:13:33.85064 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:13:33.85065 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:13:33.85065 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:13:33.85066 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:13:33.85242 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:13:33.85488 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:13:33.85525 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:13:40.85543 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:13:40.91998 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6176630062 2016-12-01T17:13:40.92547 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6176630062 2016-12-01T17:13:40.98260 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:13:40.98263 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:13:41.01477 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:13:41.01479 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:13:41.01480 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:13:41.01480 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:13:41.01481 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:13:41.01481 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:13:41.01482 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:13:41.01482 0.03121747] 2016-12-01T17:13:41.01482 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:13:41.01483 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:13:41.01484 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:13:41.01503 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:13:41.01591 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:13:41.01653 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:13:41.01857 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:13:48.02060 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:13:48.07021 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6351305052 2016-12-01T17:13:48.07062 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6351305052 2016-12-01T17:13:48.13383 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:13:48.13387 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:13:48.25078 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:13:48.25089 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:13:48.25100 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:13:48.25112 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:13:48.25215 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:13:48.25216 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:13:48.25216 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:13:48.25217 0.03121747] 2016-12-01T17:13:48.25229 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:13:48.25240 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:13:48.25251 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:13:48.25263 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:13:48.25506 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:13:48.25583 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:13:48.26104 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:13:55.26154 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:13:55.29252 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6467616121 2016-12-01T17:13:55.29318 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6467616121 2016-12-01T17:13:55.35581 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:13:55.35603 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:13:55.38827 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:13:55.38839 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:13:55.38851 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:13:55.38862 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:13:55.38958 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:13:55.38959 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:13:55.38960 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:13:55.38960 0.03121747] 2016-12-01T17:13:55.38972 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:13:55.38982 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:13:55.38993 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:13:55.39002 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:13:55.39792 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:13:55.39846 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:13:55.39871 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:14:02.39895 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:14:02.45912 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6606922045 2016-12-01T17:14:02.46062 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6606922045 2016-12-01T17:14:02.52223 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:14:02.52225 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:14:02.54257 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:14:02.54265 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:14:02.54274 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:14:02.54282 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:14:02.54374 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:14:02.54375 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:14:02.54376 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:14:02.54376 0.03121747] 2016-12-01T17:14:02.54386 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:14:02.54421 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:14:02.54422 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:14:02.54423 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:14:02.54725 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:14:02.54813 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:14:02.54841 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:14:09.54855 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:14:09.56342 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6670018563 2016-12-01T17:14:09.56543 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6670018563 2016-12-01T17:14:09.62731 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:14:09.62733 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:14:09.65127 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:14:09.65129 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:14:09.65130 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:14:09.65130 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:14:09.65131 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:14:09.65131 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:14:09.65132 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:14:09.65132 0.03121747] 2016-12-01T17:14:09.65133 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:14:09.65133 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:14:09.65134 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:14:09.65134 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:14:09.66208 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:14:09.66521 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:14:09.66555 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:14:16.66650 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:14:16.72769 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6665630287 2016-12-01T17:14:16.73177 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6665630287 2016-12-01T17:14:16.79048 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:14:16.79061 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:14:16.81339 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:14:16.81352 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:14:16.81363 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:14:16.81374 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:14:16.81470 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:14:16.81471 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:14:16.81472 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:14:16.81472 0.03121747] 2016-12-01T17:14:16.81484 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:14:16.81494 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:14:16.81505 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:14:16.81516 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:14:16.81665 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:14:16.81731 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:14:16.81762 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:14:23.81784 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:14:23.88177 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6703087033 2016-12-01T17:14:23.88340 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6703087033 2016-12-01T17:14:23.94512 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:14:23.94533 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:14:23.97257 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:14:23.97265 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:14:23.97274 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:14:23.97283 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:14:23.97372 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:14:23.97373 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:14:23.97374 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:14:23.97375 0.03121747] 2016-12-01T17:14:23.97382 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:14:23.97390 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:14:23.97398 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:14:23.97406 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:14:23.97568 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:14:23.97632 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:14:23.97666 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:14:30.97681 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:14:30.98243 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6821580523 2016-12-01T17:14:30.98352 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6821580523 2016-12-01T17:14:31.04493 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:14:31.04529 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:14:31.08054 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:14:31.08056 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:14:31.08056 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:14:31.08057 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:14:31.08148 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:14:31.08149 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:14:31.08150 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:14:31.08150 0.03121747] 2016-12-01T17:14:31.08163 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:14:31.08174 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:14:31.08185 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:14:31.08198 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:14:31.08308 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:14:31.08374 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:14:31.08409 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:14:38.08424 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:14:38.08869 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6700697608 2016-12-01T17:14:38.08962 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6700697608 2016-12-01T17:14:38.15125 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:14:38.15156 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:14:38.21783 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:14:38.21784 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:14:38.21785 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:14:38.21785 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:14:38.21786 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:14:38.21786 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:14:38.21787 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:14:38.21787 0.03121747] 2016-12-01T17:14:38.21788 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:14:38.21788 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:14:38.21788 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:14:38.21789 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:14:38.21932 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:14:38.22003 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:14:38.22034 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:14:45.22068 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:14:45.25685 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6690525101 2016-12-01T17:14:45.25930 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6690525101 2016-12-01T17:14:45.32002 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:14:45.32003 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:14:45.34749 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:14:45.34751 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:14:45.34752 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:14:45.34752 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:14:45.34821 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:14:45.34822 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:14:45.34823 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:14:45.34823 0.03121747] 2016-12-01T17:14:45.34824 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:14:45.34824 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:14:45.34825 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:14:45.34826 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:14:45.35130 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:14:45.35183 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:14:45.35205 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:14:52.35229 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:14:52.36119 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6632775578 2016-12-01T17:14:52.36771 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6632775578 2016-12-01T17:14:52.42343 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:14:52.42345 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:14:52.45555 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:14:52.45567 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:14:52.45579 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:14:52.45591 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:14:52.45670 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:14:52.45671 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:14:52.45671 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:14:52.45672 0.03121747] 2016-12-01T17:14:52.45679 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:14:52.45685 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:14:52.45693 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:14:52.45699 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:14:52.45803 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:14:52.45871 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:14:52.45902 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:14:59.45923 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:14:59.51963 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6637577141 2016-12-01T17:14:59.52029 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6637577141 2016-12-01T17:14:59.58284 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:14:59.58286 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:14:59.60544 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:14:59.60556 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:14:59.60568 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:14:59.60579 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:14:59.60676 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:14:59.60677 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:14:59.60677 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:14:59.60678 0.03121747] 2016-12-01T17:14:59.60690 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:14:59.60700 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:14:59.60711 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:14:59.60731 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:14:59.61080 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:14:59.61165 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:14:59.61189 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:15:06.61314 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:15:06.63606 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6543307112 2016-12-01T17:15:06.63704 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6543307112 2016-12-01T17:15:06.69646 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:15:06.69658 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:15:06.71858 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:15:06.71859 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:15:06.71860 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:15:06.71923 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:15:06.71985 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:15:06.71986 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:15:06.71987 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:15:06.71987 0.03121747] 2016-12-01T17:15:06.71988 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:15:06.71988 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:15:06.71991 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:15:06.72009 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:15:06.72452 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:15:06.72492 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:15:06.72514 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:15:13.72531 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:15:13.76266 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6490610548 2016-12-01T17:15:13.76422 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6490610548 2016-12-01T17:15:13.82750 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:15:13.82760 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:15:13.86368 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:15:13.86370 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:15:13.86371 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:15:13.86377 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:15:13.86492 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:15:13.86494 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:15:13.86494 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:15:13.86495 0.03121747] 2016-12-01T17:15:13.86495 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:15:13.86496 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:15:13.86701 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:15:13.86702 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:15:13.86703 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:15:13.86996 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:15:13.87044 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:15:20.87091 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:15:20.87279 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6397835966 2016-12-01T17:15:20.87979 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6397835966 2016-12-01T17:15:20.93611 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:15:20.93613 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:15:20.97380 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:15:20.97392 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:15:20.97405 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:15:20.97416 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:15:20.97513 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:15:20.97514 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:15:20.97516 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:15:20.97516 0.03121747] 2016-12-01T17:15:20.97531 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:15:20.97541 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:15:20.97552 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:15:20.97563 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:15:20.98009 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:15:20.98069 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:15:20.98098 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:15:27.98186 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:15:28.03849 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6373256862 2016-12-01T17:15:28.04060 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6373256862 2016-12-01T17:15:28.10260 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:15:28.10262 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:15:28.14941 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:15:28.14943 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:15:28.14944 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:15:28.14944 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:15:28.14945 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:15:28.14945 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:15:28.14946 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:15:28.14946 0.03121747] 2016-12-01T17:15:28.14946 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:15:28.14947 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:15:28.14947 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:15:28.14948 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:15:28.15335 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:15:28.15569 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:15:28.15599 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:15:35.15640 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:15:35.20128 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6307646307 2016-12-01T17:15:35.20177 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6307646307 2016-12-01T17:15:35.26539 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:15:35.26542 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:15:35.30142 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:15:35.30148 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:15:35.30156 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:15:35.30163 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:15:35.30234 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:15:35.30235 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:15:35.30235 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:15:35.30236 0.03121747] 2016-12-01T17:15:35.30242 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:15:35.30248 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:15:35.30254 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:15:35.30260 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:15:35.30424 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:15:35.30994 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:15:35.31023 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:15:42.31389 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:15:42.37199 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6141082004 2016-12-01T17:15:42.37628 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6141082004 2016-12-01T17:15:42.43679 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:15:42.43681 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:15:42.45993 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:15:42.45996 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:15:42.46000 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:15:42.46007 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:15:42.46072 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:15:42.46073 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:15:42.46073 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:15:42.46074 0.03121747] 2016-12-01T17:15:42.46082 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:15:42.46089 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:15:42.46099 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:15:42.46107 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:15:42.46770 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:15:42.46830 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:15:42.46851 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:15:49.46938 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:15:49.52808 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6048794506 2016-12-01T17:15:49.53195 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6048794506 2016-12-01T17:15:49.59025 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:15:49.59042 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:15:49.61967 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:15:49.61974 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:15:49.61986 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:15:49.61996 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:15:49.62050 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:15:49.62051 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:15:49.62051 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:15:49.62052 0.03121747] 2016-12-01T17:15:49.62059 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:15:49.62064 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:15:49.62069 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:15:49.62077 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:15:49.62205 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:15:49.62820 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:15:49.62869 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:15:56.62921 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:15:56.69157 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.5915125069 2016-12-01T17:15:56.69586 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.5915125069 2016-12-01T17:15:56.75465 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:15:56.75468 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:15:56.82622 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:15:56.82628 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:15:56.82752 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:15:56.82753 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:15:56.82754 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:15:56.82754 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:15:56.82755 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:15:56.82755 0.03121747] 2016-12-01T17:15:56.82756 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:15:56.82941 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:15:56.82942 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:15:56.82942 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:15:56.83912 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:15:56.84468 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:15:56.84499 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:16:03.84652 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:16:03.85462 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.5778633317 2016-12-01T17:16:03.85508 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.5778633317 2016-12-01T17:16:03.91761 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:16:03.91764 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:16:03.96192 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:16:03.96194 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:16:03.96194 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:16:03.96195 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:16:03.96328 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:16:03.96329 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:16:03.96330 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:16:03.96330 0.03121747] 2016-12-01T17:16:03.96330 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:16:03.96330 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:16:03.96331 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:16:03.96331 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:16:03.96601 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:16:03.96657 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:16:03.96686 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:16:10.96816 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:16:11.02419 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.5699310797 2016-12-01T17:16:11.02463 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.5699310797 2016-12-01T17:16:11.09402 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:16:11.09404 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:16:11.12689 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:16:11.12691 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:16:11.12692 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:16:11.12693 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:16:11.12799 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:16:11.12800 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:16:11.12800 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:16:11.12801 0.03121747] 2016-12-01T17:16:11.12801 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:16:11.12802 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:16:11.12803 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:16:11.12803 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:16:11.13186 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:16:11.13246 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:16:11.13269 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:16:18.13477 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:16:18.18189 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.5607020641 2016-12-01T17:16:18.18247 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.5607020641 2016-12-01T17:16:18.24836 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:16:18.24839 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:16:18.30090 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:16:18.30250 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:16:18.30251 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:16:18.30251 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:16:18.30252 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:16:18.30253 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:16:18.30253 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:16:18.30254 0.03121747] 2016-12-01T17:16:18.30254 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:16:18.30254 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:16:18.30255 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:16:18.30255 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:16:18.30344 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:16:18.30780 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:16:18.30782 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:16:25.30689 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:16:25.35189 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.5461038542 2016-12-01T17:16:25.35346 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.5461038542 2016-12-01T17:16:25.41545 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:16:25.41574 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:16:25.44879 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:16:25.44881 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:16:25.44881 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:16:25.44881 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:16:25.44922 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:16:25.44923 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:16:25.44924 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:16:25.44924 0.03121747] 2016-12-01T17:16:25.44931 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:16:25.44937 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:16:25.44944 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:16:25.44950 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:16:25.45141 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:16:25.45201 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:16:25.45254 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:16:32.45278 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:16:32.45475 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.5313057808 2016-12-01T17:16:32.45527 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.5313057808 2016-12-01T17:16:32.51941 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:16:32.51970 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:16:32.55285 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:16:32.55287 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:16:32.55287 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:16:32.55288 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:16:32.55288 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:16:32.55289 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:16:32.55289 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:16:32.55290 0.03121747] 2016-12-01T17:16:32.55290 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:16:32.55291 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:16:32.55291 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:16:32.55292 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:16:32.55556 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:16:32.55620 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:16:32.55655 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:16:39.55687 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:16:39.61433 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.5187628137 2016-12-01T17:16:39.61563 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.5187628137 2016-12-01T17:16:39.67589 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:16:39.67600 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:16:39.70832 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:16:39.70835 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:16:39.70847 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:16:39.70855 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:16:39.70935 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:16:39.70936 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:16:39.70937 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:16:39.70937 0.03121747] 2016-12-01T17:16:39.70944 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:16:39.70950 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:16:39.70957 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:16:39.70977 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:16:39.71147 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:16:39.71200 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:16:39.71223 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:16:46.71529 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:16:46.71761 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.5112587763 2016-12-01T17:16:46.71781 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.5112587763 2016-12-01T17:16:46.78317 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:16:46.78338 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:16:46.81182 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:16:46.81189 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:16:46.81201 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:16:46.81211 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:16:46.81270 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:16:46.81271 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:16:46.81272 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:16:46.81272 0.03121747] 2016-12-01T17:16:46.81282 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:16:46.81292 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:16:46.81301 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:16:46.81305 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:16:46.81392 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:16:46.81443 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:16:46.81463 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:16:53.81550 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:16:53.87756 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.4952847051 2016-12-01T17:16:53.87866 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.4952847051 2016-12-01T17:16:53.94002 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:16:53.94023 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:16:53.96890 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:16:53.96898 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:16:53.96908 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:16:53.96916 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:16:53.97016 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:16:53.97017 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:16:53.97018 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:16:53.97018 0.03121747] 2016-12-01T17:16:53.97030 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:16:53.97040 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:16:53.97051 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:16:53.97062 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:16:53.97169 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:16:53.97236 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:16:53.97341 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:17:00.97307 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:17:00.97877 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.4881902945 2016-12-01T17:17:00.98228 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.4881902945 2016-12-01T17:17:01.04005 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:17:01.04018 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:17:01.07453 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:17:01.07455 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:17:01.07456 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:17:01.07456 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:17:01.07457 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:17:01.07457 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:17:01.07458 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:17:01.07458 0.03121747] 2016-12-01T17:17:01.07458 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:17:01.07459 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:17:01.07459 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:17:01.07460 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:17:01.07771 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:17:01.08373 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:17:01.08428 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:17:08.08527 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:17:08.14366 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.4653263321 2016-12-01T17:17:08.14416 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.4653263321 2016-12-01T17:17:08.20612 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:17:08.20735 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:17:08.24270 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:17:08.24277 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:17:08.24284 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:17:08.24290 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:17:08.24374 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:17:08.24375 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:17:08.24376 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:17:08.24377 0.03121747] 2016-12-01T17:17:08.24390 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:17:08.24400 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:17:08.24411 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:17:08.24422 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:17:08.25912 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:17:08.26339 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:17:08.26386 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:17:15.26420 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:17:15.30962 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.4494998342 2016-12-01T17:17:15.31176 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.4494998342 2016-12-01T17:17:15.37154 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:17:15.37186 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:17:15.40812 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:17:15.40814 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:17:15.40815 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:17:15.40815 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:17:15.40816 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:17:15.40816 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:17:15.40817 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:17:15.40817 0.03121747] 2016-12-01T17:17:15.40817 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:17:15.40818 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:17:15.40818 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:17:15.40819 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:17:15.42121 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:17:15.42123 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:17:15.42124 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:17:22.41852 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:17:22.46792 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.4412116224 2016-12-01T17:17:22.46850 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.4412116224 2016-12-01T17:17:22.53226 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:17:22.53227 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:17:22.56256 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:17:22.56258 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:17:22.56258 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:17:22.56259 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:17:22.56259 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:17:22.56261 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:17:22.56262 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:17:22.56262 0.03121747] 2016-12-01T17:17:22.56263 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:17:22.56263 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:17:22.56264 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:17:22.56264 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:17:22.56529 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:17:22.56590 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:17:22.56618 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:17:29.56650 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:17:29.56850 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.4234629092 2016-12-01T17:17:29.56905 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.4234629092 2016-12-01T17:17:29.63336 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:17:29.63365 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:17:29.65892 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:17:29.65894 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:17:29.65895 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:17:29.65895 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:17:29.65896 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:17:29.65896 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:17:29.65897 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:17:29.65897 0.03121747] 2016-12-01T17:17:29.65898 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:17:29.65904 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:17:29.65914 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:17:29.65926 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:17:29.66688 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:17:29.67075 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:17:29.67102 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:17:36.67195 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:17:36.72985 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.4085923267 2016-12-01T17:17:36.73050 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.4085923267 2016-12-01T17:17:36.79933 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:17:36.79935 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:17:36.82976 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:17:36.82982 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:17:36.82990 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:17:36.82998 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:17:36.83140 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:17:36.83141 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:17:36.83142 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:17:36.83143 0.03121747] 2016-12-01T17:17:36.83143 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:17:36.83143 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:17:36.83144 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:17:36.83144 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:17:36.83820 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:17:36.83887 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:17:36.83921 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:17:43.83969 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:17:43.84250 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.3959886613 2016-12-01T17:17:43.84876 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3959886613 2016-12-01T17:17:43.90786 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:17:43.90802 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:17:43.94071 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:17:43.94078 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:17:43.94087 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:17:43.94236 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:17:43.94237 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:17:43.94238 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:17:43.94238 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:17:43.94239 0.03121747] 2016-12-01T17:17:43.94239 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:17:43.94240 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:17:43.94240 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:17:43.94241 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:17:43.94546 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:17:43.94605 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:17:43.94634 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:17:50.94652 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:17:50.94716 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.3773139274 2016-12-01T17:17:50.94772 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3773139274 2016-12-01T17:17:51.01058 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:17:51.01091 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:17:51.05049 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:17:51.05052 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:17:51.05052 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:17:51.05053 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:17:51.05053 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:17:51.05054 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:17:51.05054 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:17:51.05055 0.03121747] 2016-12-01T17:17:51.05055 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:17:51.05056 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:17:51.05056 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:17:51.05057 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:17:51.05150 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:17:51.05214 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:17:51.05243 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:17:58.05268 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:17:58.10688 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.3608160058 2016-12-01T17:17:58.10769 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3608160058 2016-12-01T17:17:58.17394 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:17:58.17397 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:17:58.23742 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:17:58.23744 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:17:58.23744 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:17:58.23744 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:17:58.23745 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:17:58.23745 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:17:58.23746 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:17:58.23746 0.03121747] 2016-12-01T17:17:58.23746 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:17:58.23747 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:17:58.23747 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:17:58.23747 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:17:58.24361 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:17:58.25080 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:17:58.25112 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:18:05.25172 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:18:05.27647 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.3485799704 2016-12-01T17:18:05.28034 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3485799704 2016-12-01T17:18:05.34268 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:18:05.34270 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:18:05.37559 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:18:05.37561 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:18:05.37562 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:18:05.37562 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:18:05.37670 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:18:05.37671 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:18:05.37672 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:18:05.37673 0.03121747] 2016-12-01T17:18:05.37673 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:18:05.37674 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:18:05.37674 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:18:05.37674 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:18:05.37782 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:18:05.37847 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:18:05.37875 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:18:12.38000 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:18:12.38622 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.3297812453 2016-12-01T17:18:12.38874 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3297812453 2016-12-01T17:18:12.45287 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:18:12.45289 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:18:12.47626 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:18:12.47628 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:18:12.47628 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:18:12.47629 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:18:12.47756 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:18:12.47757 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:18:12.47758 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:18:12.47758 0.03121747] 2016-12-01T17:18:12.47759 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:18:12.47759 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:18:12.47760 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:18:12.47760 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:18:12.48461 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:18:12.48981 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:18:12.49010 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:18:19.49082 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:18:19.49294 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.3193883583 2016-12-01T17:18:19.49356 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3193883583 2016-12-01T17:18:19.55073 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:18:19.55076 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:18:19.57540 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:18:19.57666 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:18:19.57667 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:18:19.57668 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:18:19.57669 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:18:19.57669 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:18:19.57669 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:18:19.57670 0.03121747] 2016-12-01T17:18:19.57670 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:18:19.57670 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:18:19.57671 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:18:19.57671 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:18:19.57892 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:18:19.58003 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:18:19.58034 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:18:26.58059 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:18:26.58998 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.3065217543 2016-12-01T17:18:26.59380 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3065217543 2016-12-01T17:18:26.65236 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:18:26.65239 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:18:26.68611 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:18:26.68613 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:18:26.68614 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:18:26.68614 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:18:26.68615 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:18:26.68615 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:18:26.68616 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:18:26.68616 0.03121747] 2016-12-01T17:18:26.68617 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:18:26.68617 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:18:26.68618 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:18:26.68623 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:18:26.69490 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:18:26.69603 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:18:26.69647 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:18:33.69685 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:18:33.75438 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.2926251895 2016-12-01T17:18:33.75758 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.2926251895 2016-12-01T17:18:33.81668 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:18:33.81697 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:18:33.85688 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:18:33.85691 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:18:33.85691 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:18:33.85692 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:18:33.85790 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:18:33.85791 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:18:33.85792 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:18:33.85792 0.03121747] 2016-12-01T17:18:33.85792 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:18:33.85793 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:18:33.85793 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:18:33.85794 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:18:33.85886 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:18:33.85948 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:18:33.85964 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:18:40.85988 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:18:40.91782 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.2931299102 2016-12-01T17:18:40.91784 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.2931299102 2016-12-01T17:18:40.98033 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:18:40.98035 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:18:41.01213 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:18:41.01215 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:18:41.01215 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:18:41.01216 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:18:41.01216 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:18:41.01217 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:18:41.01217 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:18:41.01218 0.03121747] 2016-12-01T17:18:41.01219 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:18:41.01247 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:18:41.01248 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:18:41.01249 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:18:41.02501 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:18:41.03000 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:18:41.03049 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:18:48.03029 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:18:48.08450 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.2886226587 2016-12-01T17:18:48.08523 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.2886226587 2016-12-01T17:18:48.14959 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:18:48.14980 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:18:48.22967 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:18:48.22975 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:18:48.22987 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:18:48.22998 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:18:48.23096 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:18:48.23097 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:18:48.23098 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:18:48.23098 0.03121747] 2016-12-01T17:18:48.23110 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:18:48.23123 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:18:48.23133 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:18:48.23144 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:18:48.23345 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:18:48.23402 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:18:48.23425 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:18:55.23491 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:18:55.25524 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.2747390017 2016-12-01T17:18:55.25872 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.2747390017 2016-12-01T17:18:55.31662 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:18:55.31695 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:18:55.36298 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:18:55.36300 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:18:55.36301 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:18:55.36461 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:18:55.36462 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:18:55.36463 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:18:55.36464 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:18:55.36464 0.03121747] 2016-12-01T17:18:55.36465 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:18:55.36465 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:18:55.36467 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:18:55.36467 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:18:55.36805 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:18:55.37278 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:18:55.37314 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:19:02.37426 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:19:02.42011 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.2696994999 2016-12-01T17:19:02.42075 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.2696994999 2016-12-01T17:19:02.48502 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:19:02.48518 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:19:02.50397 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:19:02.50403 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:19:02.50410 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:19:02.50416 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:19:02.50497 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:19:02.50498 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:19:02.50498 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:19:02.50499 0.03121747] 2016-12-01T17:19:02.50509 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:19:02.50518 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:19:02.50528 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:19:02.50535 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:19:02.51162 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:19:02.51226 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:19:02.51249 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:19:09.51263 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:19:09.52047 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.2620714645 2016-12-01T17:19:09.52383 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.2620714645 2016-12-01T17:19:09.58380 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:19:09.58396 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:19:09.60890 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:19:09.61056 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:19:09.61058 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:19:09.61058 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:19:09.61059 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:19:09.61059 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:19:09.61061 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:19:09.61062 0.03121747] 2016-12-01T17:19:09.61062 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:19:09.61063 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:19:09.61063 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:19:09.61064 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:19:09.61569 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:19:09.61834 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:19:09.61881 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:19:16.61917 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:19:16.62113 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.2651787909 2016-12-01T17:19:16.62267 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.2651787909 2016-12-01T17:19:16.68660 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:19:16.68663 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:19:16.71431 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:19:16.71434 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:19:16.71536 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:19:16.71537 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:19:16.71538 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:19:16.71538 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:19:16.71539 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:19:16.71539 0.03121747] 2016-12-01T17:19:16.71540 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:19:16.71540 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:19:16.71541 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:19:16.71541 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:19:16.72158 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:19:16.72373 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:19:16.72419 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:19:23.72451 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:19:23.78382 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.2646913014 2016-12-01T17:19:23.78423 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.2646913014 2016-12-01T17:19:23.84592 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:19:23.84623 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:19:23.87976 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:19:23.87978 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:19:23.87979 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:19:23.87979 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:19:23.88032 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:19:23.88033 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:19:23.88034 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:19:23.88034 0.03121747] 2016-12-01T17:19:23.88042 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:19:23.88056 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:19:23.88059 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:19:23.88067 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:19:23.88438 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:19:23.88602 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:19:23.88630 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:19:30.88699 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:19:30.93885 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.2607073317 2016-12-01T17:19:30.93958 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.2607073317 2016-12-01T17:19:31.00863 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:19:31.00875 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:19:31.04952 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:19:31.04960 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:19:31.04968 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:19:31.04977 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:19:31.05178 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:19:31.05180 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:19:31.05180 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:19:31.05181 0.03121747] 2016-12-01T17:19:31.05181 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:19:31.05181 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:19:31.05182 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:19:31.05182 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:19:31.06583 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:19:31.06645 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:19:31.06677 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:19:38.06724 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:19:38.11270 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.2590278782 2016-12-01T17:19:38.11796 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.2590278782 2016-12-01T17:19:38.17425 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:19:38.17462 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:19:38.20282 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:19:38.20357 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:19:38.20358 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:19:38.20359 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:19:38.20478 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:19:38.20479 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:19:38.20479 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:19:38.20480 0.03121747] 2016-12-01T17:19:38.20480 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:19:38.20481 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:19:38.20481 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:19:38.20482 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:19:38.20549 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:19:38.20625 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:19:38.20683 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:19:45.20754 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:19:45.27179 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.2587327177 2016-12-01T17:19:45.27576 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.2587327177 2016-12-01T17:19:45.33123 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:19:45.33125 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:19:45.37230 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:19:45.37232 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:19:45.37233 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:19:45.37234 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:19:45.37375 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:19:45.37376 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:19:45.37376 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:19:45.37377 0.03121747] 2016-12-01T17:19:45.37378 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:19:45.37378 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:19:45.37379 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:19:45.37379 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:19:45.38328 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:19:45.38403 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:19:45.38843 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:19:52.38862 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:19:52.43036 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.2640493019 2016-12-01T17:19:52.43180 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.2640493019 2016-12-01T17:19:52.49396 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:19:52.49399 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:19:52.53466 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:19:52.53468 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:19:52.53468 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:19:52.53469 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:19:52.53469 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:19:52.53470 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:19:52.53471 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:19:52.53471 0.03121747] 2016-12-01T17:19:52.53471 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:19:52.53473 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:19:52.53479 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:19:52.53486 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:19:52.53752 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:19:52.53817 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:19:52.53848 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:19:59.53870 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:19:59.54447 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.2592210054 2016-12-01T17:19:59.54448 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.2592210054 2016-12-01T17:19:59.60586 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:19:59.60588 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:19:59.62956 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:19:59.62967 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:19:59.62979 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:19:59.62990 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:19:59.63086 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:19:59.63087 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:19:59.63087 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:19:59.63088 0.03121747] 2016-12-01T17:19:59.63099 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:19:59.63109 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:19:59.63122 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:19:59.63133 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:19:59.63389 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:19:59.64078 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:19:59.64128 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:20:06.64157 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:20:06.64303 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.2602939578 2016-12-01T17:20:06.64354 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.2602939578 2016-12-01T17:20:06.70680 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:20:06.70709 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:20:06.74650 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:20:06.74652 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:20:06.74652 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:20:06.74653 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:20:06.74707 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:20:06.74708 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:20:06.74708 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:20:06.74709 0.03121747] 2016-12-01T17:20:06.74754 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:20:06.74756 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:20:06.74756 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:20:06.74756 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:20:06.75626 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:20:06.76152 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:20:06.76497 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:20:13.76582 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:20:13.77274 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.2583759208 2016-12-01T17:20:13.77622 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.2583759208 2016-12-01T17:20:13.83764 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:20:13.83766 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:20:13.86312 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:20:13.86315 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:20:13.86315 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:20:13.86316 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:20:13.86379 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:20:13.86380 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:20:13.86381 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:20:13.86381 0.03121747] 2016-12-01T17:20:13.86382 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:20:13.86382 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:20:13.86383 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:20:13.86383 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:20:13.87097 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:20:13.87157 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:20:13.87190 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:20:20.87210 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:20:20.88561 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.2552617635 2016-12-01T17:20:20.88622 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.2552617635 2016-12-01T17:20:20.95179 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:20:20.95181 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:20:20.98683 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:20:20.98689 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:20:20.98697 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:20:20.98703 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:20:20.98774 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:20:20.98775 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:20:20.98775 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:20:20.98776 0.03121747] 2016-12-01T17:20:20.98782 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:20:20.98787 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:20:20.98794 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:20:20.98800 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:20:20.99441 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:20:20.99522 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:20:20.99657 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:20:27.99645 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:20:28.05731 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.2539751802 2016-12-01T17:20:28.06190 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.2539751802 2016-12-01T17:20:28.11621 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:20:28.11624 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:20:28.20680 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:20:28.20682 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:20:28.20683 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:20:28.20683 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:20:28.20683 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:20:28.20684 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:20:28.20685 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:20:28.20685 0.03121747] 2016-12-01T17:20:28.20685 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:20:28.20686 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:20:28.20686 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:20:28.20687 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:20:28.20867 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:20:28.21471 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:20:28.21517 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:20:35.21659 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:20:35.27305 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.2556149851 2016-12-01T17:20:35.27542 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.2556149851 2016-12-01T17:20:35.33642 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:20:35.33675 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:20:35.36509 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:20:35.36512 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:20:35.36512 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:20:35.36513 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:20:35.36525 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:20:35.36526 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:20:35.36527 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:20:35.36527 0.03121747] 2016-12-01T17:20:35.36539 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:20:35.36551 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:20:35.36562 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:20:35.36572 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:20:35.36684 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:20:35.37633 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:20:35.37683 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:20:42.37802 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:20:42.38335 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.261612273 2016-12-01T17:20:42.38480 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.261612273 2016-12-01T17:20:42.44902 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:20:42.44916 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:20:42.48496 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:20:42.48498 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:20:42.48499 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:20:42.48499 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:20:42.48499 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:20:42.48500 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:20:42.48500 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:20:42.48500 0.03121747] 2016-12-01T17:20:42.48501 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:20:42.48501 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:20:42.48501 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:20:42.48501 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:20:42.48934 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:20:42.49001 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:20:42.49034 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:20:49.49119 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:20:49.55039 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.2629965577 2016-12-01T17:20:49.55103 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.2629965577 2016-12-01T17:20:49.61684 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:20:49.61710 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:20:49.65170 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:20:49.65177 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:20:49.65185 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:20:49.65193 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:20:49.65253 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:20:49.65254 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:20:49.65254 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:20:49.65254 0.03121747] 2016-12-01T17:20:49.65255 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:20:49.65255 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:20:49.65260 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:20:49.65265 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:20:49.65362 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:20:49.65420 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:20:49.65452 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:20:56.65474 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:20:56.70999 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.2581471315 2016-12-01T17:20:56.71108 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.2581471315 2016-12-01T17:20:56.77331 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:20:56.77344 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:20:56.80598 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:20:56.80600 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:20:56.80600 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:20:56.80601 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:20:56.80660 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:20:56.80661 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:20:56.80661 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:20:56.80662 0.03121747] 2016-12-01T17:20:56.80666 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:20:56.80674 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:20:56.80685 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:20:56.80696 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:20:56.81063 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:20:56.81376 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:20:56.81423 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:21:03.81452 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:21:03.87174 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.2615077625 2016-12-01T17:21:03.87690 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.2615077625 2016-12-01T17:21:03.93425 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:21:03.93427 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:21:03.97306 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:21:03.97309 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:21:03.97309 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:21:03.97310 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:21:03.97447 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:21:03.97448 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:21:03.97449 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:21:03.97449 0.03121747] 2016-12-01T17:21:03.97449 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:21:03.97450 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:21:03.97450 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:21:03.97451 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:21:03.97583 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:21:03.98554 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:21:03.98590 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:21:10.98649 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:21:11.04557 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.2638097975 2016-12-01T17:21:11.04730 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.2638097975 2016-12-01T17:21:11.11005 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:21:11.11007 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:21:11.13524 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:21:11.13526 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:21:11.13527 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:21:11.13528 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:21:11.13528 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:21:11.13530 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:21:11.13530 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:21:11.13531 0.03121747] 2016-12-01T17:21:11.13531 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:21:11.13532 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:21:11.13532 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:21:11.13533 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:21:11.14249 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:21:11.14877 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:21:11.14920 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:21:18.14929 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:21:18.15150 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.2689085145 2016-12-01T17:21:18.15497 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.2689085145 2016-12-01T17:21:18.21690 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:21:18.21693 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:21:18.25754 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:21:18.25756 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:21:18.25756 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:21:18.25756 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:21:18.25757 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:21:18.25757 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:21:18.25757 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:21:18.25758 0.03121747] 2016-12-01T17:21:18.25758 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:21:18.25758 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:21:18.25759 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:21:18.25759 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:21:18.26103 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:21:18.26951 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:21:18.26992 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:21:25.27084 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:21:25.31633 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.2716261217 2016-12-01T17:21:25.31792 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.2716261217 2016-12-01T17:21:25.37797 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:21:25.37799 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:21:25.41643 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:21:25.41645 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:21:25.41645 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:21:25.41646 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:21:25.41694 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:21:25.41695 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:21:25.41695 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:21:25.41696 0.03121747] 2016-12-01T17:21:25.41707 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:21:25.41717 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:21:25.41728 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:21:25.41739 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:21:25.42308 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:21:25.42741 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:21:25.42774 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:21:32.42792 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:21:32.48705 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.2748637957 2016-12-01T17:21:32.48820 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.2748637957 2016-12-01T17:21:32.55094 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:21:32.55096 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:21:32.61249 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:21:32.61251 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:21:32.61252 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:21:32.61253 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:21:32.61639 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:21:32.61641 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:21:32.61641 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:21:32.61642 0.03121747] 2016-12-01T17:21:32.61684 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:21:32.61685 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:21:32.61685 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:21:32.61686 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:21:32.62484 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:21:32.62527 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:21:32.62549 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:21:39.62709 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:21:39.65823 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.2807808688 2016-12-01T17:21:39.65903 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.2807808688 2016-12-01T17:21:39.72166 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:21:39.72179 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:21:39.75065 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:21:39.75067 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:21:39.75068 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:21:39.75069 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:21:39.75069 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:21:39.75069 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:21:39.75070 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:21:39.75070 0.03121747] 2016-12-01T17:21:39.75071 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:21:39.75071 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:21:39.75072 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:21:39.75072 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:21:39.75312 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:21:39.75380 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:21:39.75423 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:21:46.75457 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:21:46.76747 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.2946145938 2016-12-01T17:21:46.77165 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.2946145938 2016-12-01T17:21:46.83181 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:21:46.83183 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:21:46.88502 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:21:46.88508 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:21:46.88515 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:21:46.88522 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:21:46.88578 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:21:46.88579 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:21:46.88580 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:21:46.88580 0.03121747] 2016-12-01T17:21:46.88586 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:21:46.88592 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:21:46.88598 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:21:46.88605 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:21:46.88758 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:21:46.88822 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:21:46.88856 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:21:53.88868 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:21:53.92877 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.3047391959 2016-12-01T17:21:53.92932 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3047391959 2016-12-01T17:21:53.99272 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:21:53.99283 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:21:54.01547 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:21:54.01553 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:21:54.01561 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:21:54.01571 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:21:54.01651 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:21:54.01652 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:21:54.01652 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:21:54.01653 0.03121747] 2016-12-01T17:21:54.01698 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:21:54.01699 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:21:54.01701 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:21:54.01702 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:21:54.02510 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:21:54.03111 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:21:54.03159 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:22:01.03292 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:22:01.08293 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.3174341306 2016-12-01T17:22:01.08392 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3174341306 2016-12-01T17:22:01.14538 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:22:01.14549 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:22:01.20340 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:22:01.20345 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:22:01.20351 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:22:01.20359 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:22:01.20407 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:22:01.20408 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:22:01.20409 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:22:01.20410 0.03121747] 2016-12-01T17:22:01.20416 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:22:01.20417 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:22:01.20421 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:22:01.20426 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:22:01.20837 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:22:01.21402 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:22:01.21436 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:22:08.21548 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:22:08.24328 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.3248657869 2016-12-01T17:22:08.24420 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3248657869 2016-12-01T17:22:08.30694 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:22:08.30706 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:22:08.33421 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:22:08.33423 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:22:08.33423 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:22:08.33424 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:22:08.33424 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:22:08.33425 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:22:08.33425 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:22:08.33426 0.03121747] 2016-12-01T17:22:08.33426 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:22:08.33427 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:22:08.33427 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:22:08.33428 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:22:08.34125 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:22:08.34202 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:22:08.34427 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:22:15.34307 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:22:15.34472 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.3350565906 2016-12-01T17:22:15.34547 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3350565906 2016-12-01T17:22:15.40831 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:22:15.40833 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:22:15.44014 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:22:15.44016 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:22:15.44017 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:22:15.44017 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:22:15.44018 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:22:15.44018 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:22:15.44019 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:22:15.44019 0.03121747] 2016-12-01T17:22:15.44020 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:22:15.44020 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:22:15.44021 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:22:15.44021 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:22:15.44180 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:22:15.44247 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:22:15.44274 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:22:22.44592 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:22:22.45089 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.3435395984 2016-12-01T17:22:22.45200 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3435395984 2016-12-01T17:22:22.51386 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:22:22.51401 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:22:22.54471 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:22:22.54473 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:22:22.54473 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:22:22.54474 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:22:22.54505 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:22:22.54506 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:22:22.54507 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:22:22.54507 0.03121747] 2016-12-01T17:22:22.54550 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:22:22.54551 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:22:22.54552 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:22:22.54552 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:22:22.54752 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:22:22.54891 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:22:22.54911 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:22:29.54937 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:22:29.56930 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.3560457351 2016-12-01T17:22:29.57426 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3560457351 2016-12-01T17:22:29.63790 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:22:29.63792 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:22:29.67166 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:22:29.67167 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:22:29.67167 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:22:29.67168 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:22:29.67168 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:22:29.67169 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:22:29.67169 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:22:29.67170 0.03121747] 2016-12-01T17:22:29.67170 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:22:29.67171 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:22:29.67171 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:22:29.67172 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:22:29.67411 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:22:29.67473 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:22:29.67496 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:22:36.67521 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:22:36.73158 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.3653409819 2016-12-01T17:22:36.73412 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3653409819 2016-12-01T17:22:36.79590 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:22:36.79611 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:22:36.83317 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:22:36.83322 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:22:36.83328 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:22:36.83333 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:22:36.83389 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:22:36.83390 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:22:36.83390 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:22:36.83391 0.03121747] 2016-12-01T17:22:36.83395 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:22:36.83399 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:22:36.83404 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:22:36.83409 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:22:36.83535 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:22:36.84260 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:22:36.84306 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:22:43.84347 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:22:43.90222 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.3812882847 2016-12-01T17:22:43.90660 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3812882847 2016-12-01T17:22:43.96604 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:22:43.96606 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:22:44.00001 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:22:44.00003 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:22:44.00004 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:22:44.00004 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:22:44.00073 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:22:44.00074 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:22:44.00075 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:22:44.00076 0.03121747] 2016-12-01T17:22:44.00088 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:22:44.00096 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:22:44.00104 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:22:44.00110 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:22:44.00260 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:22:44.00318 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:22:44.00366 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:22:51.00393 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:22:51.01071 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.3895713906 2016-12-01T17:22:51.01255 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3895713906 2016-12-01T17:22:51.07306 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:22:51.07316 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:22:51.10196 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:22:51.10198 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:22:51.10210 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:22:51.10218 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:22:51.10303 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:22:51.10304 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:22:51.10305 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:22:51.10305 0.03121747] 2016-12-01T17:22:51.10316 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:22:51.10327 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:22:51.10338 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:22:51.10348 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:22:51.10620 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:22:51.11007 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:22:51.11052 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:22:58.11075 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:22:58.16043 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.4056360626 2016-12-01T17:22:58.16399 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.4056360626 2016-12-01T17:22:58.22301 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:22:58.22313 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:22:58.25072 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:22:58.25074 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:22:58.25075 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:22:58.25075 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:22:58.25174 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:22:58.25175 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:22:58.25177 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:22:58.25177 0.03121747] 2016-12-01T17:22:58.25178 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:22:58.25178 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:22:58.25179 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:22:58.25180 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:22:58.25891 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:22:58.26067 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:22:58.26106 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:23:05.26272 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:23:05.26337 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.4073568733 2016-12-01T17:23:05.26405 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.4073568733 2016-12-01T17:23:05.32619 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:23:05.32630 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:23:05.35396 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:23:05.35407 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:23:05.35418 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:23:05.35428 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:23:05.35516 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:23:05.35517 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:23:05.35517 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:23:05.35518 0.03121747] 2016-12-01T17:23:05.35530 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:23:05.35539 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:23:05.35549 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:23:05.35559 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:23:05.36361 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:23:05.36632 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:23:05.36654 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:23:12.36695 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:23:12.41832 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.4225103063 2016-12-01T17:23:12.41953 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.4225103063 2016-12-01T17:23:12.48132 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:23:12.48134 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:23:12.51557 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:23:12.51560 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:23:12.51560 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:23:12.51561 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:23:12.51622 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:23:12.51623 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:23:12.51624 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:23:12.51624 0.03121747] 2016-12-01T17:23:12.51636 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:23:12.51646 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:23:12.51657 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:23:12.51668 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:23:12.52699 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:23:12.52817 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:23:12.53235 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:23:19.53327 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:23:19.59130 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.4309501669 2016-12-01T17:23:19.59192 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.4309501669 2016-12-01T17:23:19.65578 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:23:19.65580 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:23:19.68853 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:23:19.68865 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:23:19.68877 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:23:19.68888 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:23:19.68983 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:23:19.68984 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:23:19.68985 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:23:19.68986 0.03121747] 2016-12-01T17:23:19.68997 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:23:19.69007 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:23:19.69018 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:23:19.69029 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:23:19.69132 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:23:19.69215 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:23:19.69247 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:23:26.69265 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:23:26.75547 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.4333561705 2016-12-01T17:23:26.75592 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.4333561705 2016-12-01T17:23:26.81890 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:23:26.81892 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:23:26.86165 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:23:26.86174 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:23:26.86183 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:23:26.86194 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:23:26.86247 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:23:26.86248 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:23:26.86248 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:23:26.86249 0.03121747] 2016-12-01T17:23:26.86265 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:23:26.86265 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:23:26.86270 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:23:26.86280 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:23:26.86382 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:23:26.86441 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:23:26.86462 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:23:33.86584 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:23:33.87033 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.4462878611 2016-12-01T17:23:33.87388 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.4462878611 2016-12-01T17:23:33.93043 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:23:33.93057 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:23:33.98146 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:23:33.98148 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:23:33.98149 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:23:33.98149 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:23:33.98241 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:23:33.98242 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:23:33.98242 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:23:33.98243 0.03121747] 2016-12-01T17:23:33.98246 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:23:33.98254 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:23:33.98262 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:23:33.98270 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:23:33.99107 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:23:33.99207 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:23:33.99239 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:23:40.99452 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:23:41.02431 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.4528466946 2016-12-01T17:23:41.02528 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.4528466946 2016-12-01T17:23:41.08781 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:23:41.08784 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:23:41.11205 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:23:41.11213 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:23:41.11226 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:23:41.11237 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:23:41.11345 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:23:41.11345 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:23:41.11346 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:23:41.11346 0.03121747] 2016-12-01T17:23:41.11347 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:23:41.11357 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:23:41.11363 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:23:41.11371 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:23:41.12372 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:23:41.12747 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:23:41.12795 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:23:48.12961 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:23:48.13084 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.4555534378 2016-12-01T17:23:48.13136 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.4555534378 2016-12-01T17:23:48.19349 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:23:48.19361 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:23:48.50573 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:23:48.50576 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:23:48.50576 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:23:48.50577 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:23:48.50577 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:23:48.50578 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:23:48.50578 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:23:48.50579 0.03121747] 2016-12-01T17:23:48.50579 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:23:48.50579 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:23:48.50580 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:23:48.50580 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:23:48.51442 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:23:48.51655 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:23:48.51859 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:23:55.52026 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:23:55.53923 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.4726701925 2016-12-01T17:23:55.54100 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.4726701925 2016-12-01T17:23:55.60440 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:23:55.60444 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:23:55.64158 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:23:55.64160 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:23:55.64160 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:23:55.64161 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:23:55.64161 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:23:55.64162 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:23:55.64162 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:23:55.64163 0.03121747] 2016-12-01T17:23:55.64163 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:23:55.64164 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:23:55.64164 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:23:55.64165 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:23:55.64886 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:23:55.65389 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:23:55.65437 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:24:02.65475 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:24:02.70667 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.4797336363 2016-12-01T17:24:02.70730 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.4797336363 2016-12-01T17:24:02.76995 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:24:02.76997 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:24:03.01837 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:24:03.01844 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:24:03.01855 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:24:03.01865 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:24:03.01953 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:24:03.01954 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:24:03.01955 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:24:03.01955 0.03121747] 2016-12-01T17:24:03.01966 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:24:03.01976 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:24:03.01986 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:24:03.01997 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:24:03.02465 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:24:03.02528 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:24:03.02557 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:24:10.02610 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:24:10.05569 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.4966613047 2016-12-01T17:24:10.05628 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.4966613047 2016-12-01T17:24:10.11866 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:24:10.11868 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:24:10.14842 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:24:10.14845 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:24:10.14845 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:24:10.14846 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:24:10.14846 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:24:10.14847 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:24:10.14847 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:24:10.14850 0.03121747] 2016-12-01T17:24:10.14850 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:24:10.14851 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:24:10.14851 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:24:10.14851 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:24:10.14948 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:24:10.15015 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:24:10.15027 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:24:17.15263 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:24:17.16773 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.504483156 2016-12-01T17:24:17.16888 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.504483156 2016-12-01T17:24:17.22705 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:24:17.22739 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:24:17.25807 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:24:17.25809 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:24:17.25810 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:24:17.25810 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:24:17.25811 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:24:17.25811 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:24:17.25812 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:24:17.25812 0.03121747] 2016-12-01T17:24:17.25813 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:24:17.25813 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:24:17.25814 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:24:17.25814 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:24:17.25902 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:24:17.26477 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:24:17.26543 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:24:24.26802 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:24:24.26988 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.5162277765 2016-12-01T17:24:24.26989 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.5162277765 2016-12-01T17:24:24.33170 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:24:24.33172 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:24:24.36431 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:24:24.36433 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:24:24.36434 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:24:24.36434 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:24:24.36509 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:24:24.36510 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:24:24.36511 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:24:24.36511 0.03121747] 2016-12-01T17:24:24.36512 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:24:24.36512 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:24:24.36513 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:24:24.36513 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:24:24.36610 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:24:24.36687 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:24:24.37152 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:24:31.36796 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:24:31.42495 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.5265571551 2016-12-01T17:24:31.42555 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.5265571551 2016-12-01T17:24:31.48828 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:24:31.48849 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:24:31.52278 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:24:31.52285 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:24:31.52297 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:24:31.52301 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:24:31.52358 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:24:31.52358 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:24:31.52359 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:24:31.52359 0.03121747] 2016-12-01T17:24:31.52360 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:24:31.52368 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:24:31.52369 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:24:31.52377 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:24:31.52598 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:24:31.52743 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:24:31.53068 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:24:38.52822 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:24:38.58377 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.5350879064 2016-12-01T17:24:38.58839 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.5350879064 2016-12-01T17:24:38.64268 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:24:38.64290 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:24:38.73167 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:24:38.73179 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:24:38.73190 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:24:38.73201 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:24:38.73256 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:24:38.73257 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:24:38.73258 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:24:38.73258 0.03121747] 2016-12-01T17:24:38.73264 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:24:38.73270 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:24:38.73277 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:24:38.73283 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:24:38.73377 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:24:38.74234 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:24:38.74330 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:24:45.74722 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:24:45.80311 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.5503835772 2016-12-01T17:24:45.80380 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.5503835772 2016-12-01T17:24:45.86659 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:24:45.86671 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:24:45.89150 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:24:45.89152 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:24:45.89158 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:24:45.89211 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:24:45.89239 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:24:45.89240 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:24:45.89241 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:24:45.89241 0.03121747] 2016-12-01T17:24:45.89248 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:24:45.89253 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:24:45.89260 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:24:45.89266 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:24:45.89690 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:24:45.89813 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:24:45.89868 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:24:52.89903 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:24:52.90606 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.5602348297 2016-12-01T17:24:52.90671 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.5602348297 2016-12-01T17:24:52.96685 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:24:52.96707 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:24:53.03126 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:24:53.03128 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:24:53.03129 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:24:53.03129 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:24:53.03130 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:24:53.03130 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:24:53.03131 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:24:53.03131 0.03121747] 2016-12-01T17:24:53.03132 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:24:53.03132 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:24:53.03133 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:24:53.03133 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:24:53.03480 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:24:53.03545 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:24:53.03755 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:25:00.03922 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:25:00.08688 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.580866419 2016-12-01T17:25:00.08790 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.580866419 2016-12-01T17:25:00.14844 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:25:00.14846 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:25:00.17835 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:25:00.17837 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:25:00.17930 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:25:00.17931 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:25:00.17953 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:25:00.17955 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:25:00.17956 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:25:00.17956 0.03121747] 2016-12-01T17:25:00.17968 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:25:00.17977 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:25:00.17988 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:25:00.17999 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:25:00.18159 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:25:00.18225 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:25:00.18256 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:25:07.18276 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:25:07.19516 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.582039303 2016-12-01T17:25:07.19592 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.582039303 2016-12-01T17:25:07.26137 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:25:07.26141 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:25:07.31088 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:25:07.31092 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:25:07.31214 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:25:07.31215 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:25:07.31216 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:25:07.31216 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:25:07.31217 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:25:07.31217 0.03121747] 2016-12-01T17:25:07.31218 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:25:07.31255 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:25:07.31256 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:25:07.31256 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:25:07.31778 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:25:07.31838 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:25:07.31860 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:25:14.31901 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:25:14.38672 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.5881329164 2016-12-01T17:25:14.38873 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.5881329164 2016-12-01T17:25:14.44619 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:25:14.44622 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:25:14.49177 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:25:14.49179 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:25:14.49327 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:25:14.49329 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:25:14.49330 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:25:14.49330 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:25:14.49331 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:25:14.49331 0.03121747] 2016-12-01T17:25:14.49332 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:25:14.49332 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:25:14.49333 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:25:14.49333 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:25:14.51414 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:25:14.51930 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:25:14.52136 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:25:21.52181 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:25:21.55295 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6003101098 2016-12-01T17:25:21.55556 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6003101098 2016-12-01T17:25:21.61653 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:25:21.61669 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:25:21.64709 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:25:21.64711 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:25:21.65089 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:25:21.65090 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:25:21.65091 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:25:21.65091 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:25:21.65092 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:25:21.65092 0.03121747] 2016-12-01T17:25:21.65093 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:25:21.65093 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:25:21.65094 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:25:21.65094 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:25:21.65094 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:25:21.65095 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:25:21.65095 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:25:28.65077 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:25:28.70825 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6133071168 2016-12-01T17:25:28.70873 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6133071168 2016-12-01T17:25:28.77209 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:25:28.77243 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:25:28.81312 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:25:28.81314 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:25:28.81414 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:25:28.81415 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:25:28.81415 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:25:28.81416 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:25:28.81417 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:25:28.81417 0.03121747] 2016-12-01T17:25:28.81417 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:25:28.81418 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:25:28.81418 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:25:28.81419 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:25:28.81510 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:25:28.81576 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:25:28.81666 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:25:35.81684 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:25:35.87784 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6151353684 2016-12-01T17:25:35.88357 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6151353684 2016-12-01T17:25:35.94124 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:25:35.94126 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:25:35.98274 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:25:35.98276 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:25:35.98276 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:25:35.98277 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:25:35.98277 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:25:35.98278 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:25:35.98278 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:25:35.98279 0.03121747] 2016-12-01T17:25:35.98279 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:25:35.98280 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:25:35.98280 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:25:35.98281 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:25:35.99456 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:25:36.00261 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:25:36.00313 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:25:43.00354 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:25:43.04216 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6266635296 2016-12-01T17:25:43.04285 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6266635296 2016-12-01T17:25:43.10289 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:25:43.10292 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:25:43.13757 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:25:43.13758 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:25:43.13759 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:25:43.13759 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:25:43.13760 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:25:43.13760 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:25:43.13761 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:25:43.13761 0.03121747] 2016-12-01T17:25:43.13761 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:25:43.13762 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:25:43.13762 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:25:43.13763 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:25:43.14730 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:25:43.15010 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:25:43.15035 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:25:50.15052 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:25:50.19704 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6260493949 2016-12-01T17:25:50.19756 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6260493949 2016-12-01T17:25:50.26144 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:25:50.26244 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:25:50.33428 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:25:50.33440 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:25:50.33452 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:25:50.33460 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:25:50.33560 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:25:50.33562 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:25:50.33562 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:25:50.33563 0.03121747] 2016-12-01T17:25:50.33570 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:25:50.33574 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:25:50.33582 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:25:50.33590 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:25:50.34065 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:25:50.34140 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:25:50.34330 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:25:57.34193 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:25:57.36190 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6300883482 2016-12-01T17:25:57.36483 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6300883482 2016-12-01T17:25:57.42483 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:25:57.42485 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:25:57.46046 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:25:57.46052 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:25:57.46060 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:25:57.46067 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:25:57.46172 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:25:57.46173 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:25:57.46174 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:25:57.46174 0.03121747] 2016-12-01T17:25:57.46175 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:25:57.46175 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:25:57.46176 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:25:57.46177 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:25:57.46740 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:25:57.46807 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:25:57.46868 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:26:04.46932 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:26:04.53102 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6417214767 2016-12-01T17:26:04.53402 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6417214767 2016-12-01T17:26:04.59150 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:26:04.59152 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:26:04.63118 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:26:04.63122 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:26:04.63123 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:26:04.63123 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:26:04.63205 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:26:04.63206 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:26:04.63207 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:26:04.63207 0.03121747] 2016-12-01T17:26:04.63208 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:26:04.63208 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:26:04.63209 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:26:04.63209 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:26:04.63907 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:26:04.64468 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:26:04.64517 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:26:11.64548 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:26:11.69098 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6556814584 2016-12-01T17:26:11.69579 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6556814584 2016-12-01T17:26:11.75446 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:26:11.75448 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:26:11.78952 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:26:11.78954 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:26:11.78955 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:26:11.78955 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:26:11.79045 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:26:11.79046 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:26:11.79047 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:26:11.79047 0.03121747] 2016-12-01T17:26:11.79048 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:26:11.79048 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:26:11.79049 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:26:11.79049 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:26:11.79196 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:26:11.79675 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:26:11.79721 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:26:18.79747 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:26:18.80148 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6501940443 2016-12-01T17:26:18.80203 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6501940443 2016-12-01T17:26:18.86108 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:26:18.86135 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:26:18.95416 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:26:18.95528 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:26:18.95530 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:26:18.95530 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:26:18.95547 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:26:18.95548 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:26:18.95548 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:26:18.95549 0.03121747] 2016-12-01T17:26:18.95550 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:26:18.95551 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:26:18.95791 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:26:18.95792 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:26:18.95975 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:26:18.96203 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:26:18.96242 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:26:25.96381 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:26:25.96656 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6603733502 2016-12-01T17:26:25.96710 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6603733502 2016-12-01T17:26:26.02611 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:26:26.02623 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:26:26.05244 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:26:26.05285 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:26:26.05286 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:26:26.05286 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:26:26.05411 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:26:26.05412 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:26:26.05412 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:26:26.05413 0.03121747] 2016-12-01T17:26:26.05413 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:26:26.05414 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:26:26.05414 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:26:26.05415 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:26:26.05872 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:26:26.05971 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:26:26.06062 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:26:33.06224 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:26:33.06340 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6616713631 2016-12-01T17:26:33.06403 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6616713631 2016-12-01T17:26:33.12759 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:26:33.12761 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:26:33.23993 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:26:33.24005 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:26:33.24017 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:26:33.24030 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:26:33.24139 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:26:33.24142 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:26:33.24143 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:26:33.24143 0.03121747] 2016-12-01T17:26:33.24157 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:26:33.24171 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:26:33.24185 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:26:33.24196 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:26:33.24417 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:26:33.24511 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:26:33.24542 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:26:40.24600 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:26:40.28351 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6765678999 2016-12-01T17:26:40.28416 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6765678999 2016-12-01T17:26:40.34542 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:26:40.34553 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:26:40.38436 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:26:40.38440 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:26:40.38446 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:26:40.38450 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:26:40.38500 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:26:40.38501 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:26:40.38501 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:26:40.38502 0.03121747] 2016-12-01T17:26:40.38505 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:26:40.38509 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:26:40.38514 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:26:40.38518 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:26:40.38667 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:26:40.39543 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:26:40.39572 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:26:47.39659 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:26:47.44737 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6718465922 2016-12-01T17:26:47.44830 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6718465922 2016-12-01T17:26:47.50940 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:26:47.50961 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:26:47.54549 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:26:47.54560 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:26:47.54572 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:26:47.54583 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:26:47.54674 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:26:47.54675 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:26:47.54677 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:26:47.54678 0.03121747] 2016-12-01T17:26:47.54690 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:26:47.54699 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:26:47.54710 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:26:47.54721 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:26:47.55604 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:26:47.56011 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:26:47.56075 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:26:54.56108 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:26:54.60445 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6812150999 2016-12-01T17:26:54.60519 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6812150999 2016-12-01T17:26:54.66767 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:26:54.66769 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:26:54.72066 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:26:54.72068 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:26:54.72069 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:26:54.72070 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:26:54.72193 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:26:54.72194 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:26:54.72194 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:26:54.72195 0.03121747] 2016-12-01T17:26:54.72195 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:26:54.72196 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:26:54.72196 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:26:54.72196 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:26:54.72284 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:26:54.72340 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:26:54.72365 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:27:01.72450 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:27:01.75229 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6804233558 2016-12-01T17:27:01.75431 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6804233558 2016-12-01T17:27:01.81560 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:27:01.81565 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:27:01.84396 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:27:01.84403 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:27:01.84412 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:27:01.84423 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:27:01.84514 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:27:01.84515 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:27:01.84516 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:27:01.84516 0.03121747] 2016-12-01T17:27:01.84527 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:27:01.84536 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:27:01.84546 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:27:01.84556 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:27:01.85453 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:27:01.85501 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:27:01.85532 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:27:08.85579 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:27:08.90806 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6919794247 2016-12-01T17:27:08.91179 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6919794247 2016-12-01T17:27:08.96885 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:27:08.96902 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:27:09.05009 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:27:09.05011 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:27:09.05011 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:27:09.05012 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:27:09.05012 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:27:09.05013 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:27:09.05013 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:27:09.05014 0.03121747] 2016-12-01T17:27:09.05014 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:27:09.05015 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:27:09.05015 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:27:09.05016 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:27:09.05602 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:27:09.05741 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:27:09.05773 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:27:16.05800 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:27:16.06905 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6872409951 2016-12-01T17:27:16.06962 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6872409951 2016-12-01T17:27:16.13218 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:27:16.13220 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:27:16.16415 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:27:16.16418 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:27:16.16418 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:27:16.16419 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:27:16.16419 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:27:16.16420 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:27:16.16420 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:27:16.16421 0.03121747] 2016-12-01T17:27:16.16421 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:27:16.16422 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:27:16.16422 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:27:16.16423 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:27:16.16964 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:27:16.17435 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:27:16.17467 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:27:23.17545 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:27:23.23279 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6910755673 2016-12-01T17:27:23.23583 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6910755673 2016-12-01T17:27:23.29343 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:27:23.29345 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:27:23.42626 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:27:23.42628 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:27:23.42628 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:27:23.42629 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:27:23.42629 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:27:23.42629 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:27:23.42630 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:27:23.42630 0.03121747] 2016-12-01T17:27:23.42630 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:27:23.42631 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:27:23.42631 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:27:23.42631 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:27:23.43167 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:27:23.43220 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:27:23.43249 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:27:30.43361 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:27:30.47202 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6957250357 2016-12-01T17:27:30.47531 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6957250357 2016-12-01T17:27:30.53501 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:27:30.53513 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:27:30.56363 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:27:30.56371 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:27:30.56379 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:27:30.56387 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:27:30.56524 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:27:30.56525 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:27:30.56526 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:27:30.56527 0.03121747] 2016-12-01T17:27:30.56527 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:27:30.56528 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:27:30.56528 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:27:30.56529 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:27:30.57370 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:27:30.57372 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:27:30.57373 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:27:37.57515 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:27:37.58093 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6968813908 2016-12-01T17:27:37.58406 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6968813908 2016-12-01T17:27:37.64498 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:27:37.64501 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:27:38.12963 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:27:38.12965 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:27:38.12966 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:27:38.12966 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:27:38.13105 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:27:38.13107 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:27:38.13107 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:27:38.13108 0.03121747] 2016-12-01T17:27:38.13108 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:27:38.13109 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:27:38.13109 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:27:38.13109 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:27:38.14502 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:27:38.15243 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:27:38.15629 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:27:45.15293 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:27:45.19294 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6983963198 2016-12-01T17:27:45.19352 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6983963198 2016-12-01T17:27:45.25934 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:27:45.25945 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:27:45.29507 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:27:45.29509 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:27:45.29510 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:27:45.29639 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:27:45.29640 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:27:45.29641 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:27:45.29642 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:27:45.29642 0.03121747] 2016-12-01T17:27:45.29642 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:27:45.29643 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:27:45.29643 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:27:45.29644 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:27:45.29976 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:27:45.30035 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:27:45.30062 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:27:52.30089 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:27:52.35860 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6930786181 2016-12-01T17:27:52.35928 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6930786181 2016-12-01T17:27:52.42411 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:27:52.42432 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:27:52.45454 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:27:52.45461 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:27:52.45469 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:27:52.45476 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:27:52.45536 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:27:52.45537 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:27:52.45538 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:27:52.45538 0.03121747] 2016-12-01T17:27:52.45544 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:27:52.45550 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:27:52.45557 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:27:52.45568 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:27:52.46377 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:27:52.46586 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:27:52.46610 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:27:59.46626 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:27:59.52409 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6985036738 2016-12-01T17:27:59.52556 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6985036738 2016-12-01T17:27:59.58731 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:27:59.58733 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:27:59.61711 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:27:59.61723 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:27:59.61735 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:27:59.61746 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:27:59.61847 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:27:59.61848 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:27:59.61849 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:27:59.61849 0.03121747] 2016-12-01T17:27:59.61861 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:27:59.61871 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:27:59.61882 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:27:59.61893 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:27:59.62832 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:27:59.62899 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:27:59.62947 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:28:06.62992 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:28:06.67925 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.7027353307 2016-12-01T17:28:06.68049 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.7027353307 2016-12-01T17:28:06.74606 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:28:06.74633 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:28:06.78463 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:28:06.78466 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:28:06.78574 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:28:06.78575 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:28:06.78575 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:28:06.78576 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:28:06.78577 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:28:06.78577 0.03121747] 2016-12-01T17:28:06.78620 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:28:06.78621 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:28:06.78622 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:28:06.78623 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:28:06.78914 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:28:06.79446 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:28:06.79496 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:28:13.79533 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:28:13.85157 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6989997096 2016-12-01T17:28:13.85335 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6989997096 2016-12-01T17:28:13.91375 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:28:13.91395 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:28:13.95486 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:28:13.95499 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:28:13.95511 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:28:13.95524 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:28:13.95625 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:28:13.95626 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:28:13.95627 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:28:13.95627 0.03121747] 2016-12-01T17:28:13.95717 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:28:13.95727 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:28:13.95738 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:28:13.95750 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:28:13.95864 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:28:13.95922 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:28:13.95992 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:28:20.96033 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:28:21.00438 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6988809867 2016-12-01T17:28:21.00671 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6988809867 2016-12-01T17:28:21.06617 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:28:21.06638 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:28:21.09991 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:28:21.09998 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:28:21.10005 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:28:21.10012 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:28:21.10068 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:28:21.10069 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:28:21.10069 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:28:21.10070 0.03121747] 2016-12-01T17:28:21.10075 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:28:21.10081 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:28:21.10088 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:28:21.10094 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:28:21.11626 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:28:21.12658 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:28:21.12918 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:28:28.13050 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:28:28.17055 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.7067793883 2016-12-01T17:28:28.17356 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.7067793883 2016-12-01T17:28:28.23541 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:28:28.23555 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:28:28.27443 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:28:28.27454 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:28:28.27466 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:28:28.27477 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:28:28.27573 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:28:28.27575 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:28:28.27575 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:28:28.27576 0.03121747] 2016-12-01T17:28:28.27588 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:28:28.27597 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:28:28.27608 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:28:28.27619 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:28:28.29147 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:28:28.29732 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:28:28.29784 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:28:35.29817 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:28:35.32660 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6988221711 2016-12-01T17:28:35.33276 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6988221711 2016-12-01T17:28:35.39133 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:28:35.39146 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:28:35.41857 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:28:35.41860 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:28:35.41860 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:28:35.41861 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:28:35.41861 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:28:35.41862 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:28:35.41862 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:28:35.41863 0.03121747] 2016-12-01T17:28:35.41864 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:28:35.41865 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:28:35.41865 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:28:35.41866 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:28:35.42182 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:28:35.42248 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:28:35.42281 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:28:42.42303 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:28:42.42904 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.7080533321 2016-12-01T17:28:42.42966 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.7080533321 2016-12-01T17:28:42.49375 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:28:42.49411 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:28:42.52166 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:28:42.52168 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:28:42.52168 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:28:42.52169 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:28:42.52169 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:28:42.52170 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:28:42.52171 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:28:42.52171 0.03121747] 2016-12-01T17:28:42.52172 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:28:42.52172 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:28:42.52173 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:28:42.52173 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:28:42.53003 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:28:42.53060 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:28:42.53107 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:28:49.53188 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:28:49.53996 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6984715269 2016-12-01T17:28:49.54048 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6984715269 2016-12-01T17:28:49.60417 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:28:49.60419 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:28:49.63589 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:28:49.63591 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:28:49.63591 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:28:49.63592 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:28:49.63707 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:28:49.63710 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:28:49.63710 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:28:49.63711 0.03121747] 2016-12-01T17:28:49.63711 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:28:49.63712 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:28:49.63712 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:28:49.63713 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:28:49.64508 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:28:49.65050 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:28:49.65080 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:28:56.65103 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:28:56.70914 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6939899731 2016-12-01T17:28:56.71352 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6939899731 2016-12-01T17:28:56.77129 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:28:56.77132 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:28:56.79668 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:28:56.79670 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:28:56.79671 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:28:56.79671 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:28:56.79672 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:28:56.79672 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:28:56.79673 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:28:56.79673 0.03121747] 2016-12-01T17:28:56.79674 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:28:56.79674 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:28:56.79675 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:28:56.79676 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:28:56.79790 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:28:56.80209 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:28:56.80251 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:29:03.80509 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:29:03.86795 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.7015636292 2016-12-01T17:29:03.86865 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.7015636292 2016-12-01T17:29:03.93133 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:29:03.93153 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:29:03.95246 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:29:03.95252 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:29:03.95260 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:29:03.95267 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:29:03.95326 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:29:03.95327 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:29:03.95327 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:29:03.95328 0.03121747] 2016-12-01T17:29:03.95334 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:29:03.95339 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:29:03.95346 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:29:03.95352 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:29:03.95676 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:29:03.96035 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:29:03.96176 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:29:10.96202 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:29:10.97195 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.7022707785 2016-12-01T17:29:10.97480 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.7022707785 2016-12-01T17:29:11.04176 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:29:11.04178 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:29:11.07173 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:29:11.07175 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:29:11.07175 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:29:11.07176 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:29:11.07230 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:29:11.07231 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:29:11.07231 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:29:11.07232 0.03121747] 2016-12-01T17:29:11.07239 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:29:11.07247 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:29:11.07255 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:29:11.07265 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:29:11.07381 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:29:11.07516 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:29:11.07542 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:29:18.07558 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:29:18.07930 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.7066759152 2016-12-01T17:29:18.08109 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.7066759152 2016-12-01T17:29:18.13859 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:29:18.13861 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:29:18.31885 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:29:18.31887 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:29:18.31887 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:29:18.31888 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:29:18.31888 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:29:18.31889 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:29:18.31889 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:29:18.31890 0.03121747] 2016-12-01T17:29:18.31890 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:29:18.31891 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:29:18.31891 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:29:18.31892 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:29:18.32031 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:29:18.32267 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:29:18.32354 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:29:25.32538 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:29:25.36686 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6973824732 2016-12-01T17:29:25.37513 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6973824732 2016-12-01T17:29:25.42956 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:29:25.42958 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:29:25.46662 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:29:25.46664 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:29:25.46665 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:29:25.46665 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:29:25.46690 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:29:25.46691 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:29:25.46692 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:29:25.46692 0.03121747] 2016-12-01T17:29:25.46699 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:29:25.46706 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:29:25.46713 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:29:25.46722 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:29:25.46830 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:29:25.47251 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:29:25.47300 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:29:32.47318 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:29:32.47879 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6950788934 2016-12-01T17:29:32.48437 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6950788934 2016-12-01T17:29:32.54260 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:29:32.54262 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:29:32.56967 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:29:32.56969 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:29:32.56969 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:29:32.56970 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:29:32.57045 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:29:32.57046 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:29:32.57047 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:29:32.57047 0.03121747] 2016-12-01T17:29:32.57059 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:29:32.57069 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:29:32.57080 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:29:32.57090 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:29:32.57808 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:29:32.58260 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:29:32.58285 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:29:39.58332 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:29:39.64496 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6994599949 2016-12-01T17:29:39.64746 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6994599949 2016-12-01T17:29:39.70504 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:29:39.70516 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:29:39.73748 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:29:39.73750 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:29:39.73750 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:29:39.73751 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:29:39.73849 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:29:39.73850 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:29:39.73850 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:29:39.73850 0.03121747] 2016-12-01T17:29:39.73865 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:29:39.73873 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:29:39.73883 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:29:39.73893 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:29:39.74340 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:29:39.74406 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:29:39.74672 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:29:46.74707 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:29:46.80920 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6958699907 2016-12-01T17:29:46.81581 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6958699907 2016-12-01T17:29:46.87573 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:29:46.87575 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:29:46.91766 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:29:46.91769 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:29:46.91769 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:29:46.91770 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:29:46.91770 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:29:46.91771 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:29:46.91771 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:29:46.91772 0.03121747] 2016-12-01T17:29:46.91772 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:29:46.91772 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:29:46.91773 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:29:46.91773 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:29:46.92232 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:29:46.92494 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:29:46.92517 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:29:53.92549 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:29:53.97665 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6906583462 2016-12-01T17:29:53.97850 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6906583462 2016-12-01T17:29:54.04055 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:29:54.04057 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:29:54.06920 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:29:54.06929 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:29:54.06998 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:29:54.06999 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:29:54.07086 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:29:54.07087 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:29:54.07088 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:29:54.07089 0.03121747] 2016-12-01T17:29:54.07089 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:29:54.07090 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:29:54.07090 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:29:54.07091 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:29:54.07235 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:29:54.07301 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:29:54.07340 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:30:01.07367 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:30:01.08978 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6930994195 2016-12-01T17:30:01.09024 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6930994195 2016-12-01T17:30:01.15276 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:30:01.15278 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:30:01.21290 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:30:01.21292 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:30:01.21292 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:30:01.21293 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:30:01.21293 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:30:01.21294 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:30:01.21294 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:30:01.21295 0.03121747] 2016-12-01T17:30:01.21295 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:30:01.21296 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:30:01.21296 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:30:01.21297 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:30:01.21667 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:30:01.21733 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:30:01.21767 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:30:08.21849 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:30:08.22403 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6877684483 2016-12-01T17:30:08.23030 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6877684483 2016-12-01T17:30:08.28739 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:30:08.28741 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:30:08.31655 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:30:08.31657 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:30:08.31658 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:30:08.31658 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:30:08.31736 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:30:08.31737 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:30:08.31738 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:30:08.31738 0.03121747] 2016-12-01T17:30:08.31739 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:30:08.31739 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:30:08.31740 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:30:08.31740 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:30:08.32842 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:30:08.33585 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:30:08.33638 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:30:15.33767 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:30:15.34317 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6871499708 2016-12-01T17:30:15.34492 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6871499708 2016-12-01T17:30:15.40461 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:30:15.40472 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:30:15.43443 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:30:15.43445 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:30:15.43446 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:30:15.43446 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:30:15.43447 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:30:15.43447 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:30:15.43448 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:30:15.43448 0.03121747] 2016-12-01T17:30:15.43449 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:30:15.43449 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:30:15.43449 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:30:15.43450 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:30:15.43948 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:30:15.44279 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:30:15.44325 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:30:22.44526 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:30:22.50487 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6933335158 2016-12-01T17:30:22.50532 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6933335158 2016-12-01T17:30:22.56873 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:30:22.56875 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:30:22.61158 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:30:22.61165 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:30:22.61216 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:30:22.61217 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:30:22.61297 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:30:22.61298 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:30:22.61299 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:30:22.61299 0.03121747] 2016-12-01T17:30:22.61299 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:30:22.61300 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:30:22.61301 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:30:22.61302 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:30:22.61810 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:30:22.61859 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:30:22.61908 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:30:29.61945 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:30:29.66162 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6856680442 2016-12-01T17:30:29.66211 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6856680442 2016-12-01T17:30:29.72845 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:30:29.72848 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:30:29.75428 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:30:29.75524 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:30:29.75525 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:30:29.75526 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:30:29.75566 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:30:29.75567 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:30:29.75567 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:30:29.75568 0.03121747] 2016-12-01T17:30:29.75580 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:30:29.75594 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:30:29.75619 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:30:29.75635 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:30:29.76244 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:30:29.76311 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:30:29.76367 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:30:36.76426 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:30:36.82537 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6796637911 2016-12-01T17:30:36.82540 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6796637911 2016-12-01T17:30:36.88842 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:30:36.88863 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:30:36.91547 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:30:36.91560 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:30:36.91572 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:30:36.91583 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:30:36.91679 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:30:36.91680 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:30:36.91682 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:30:36.91683 0.03121747] 2016-12-01T17:30:36.91695 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:30:36.91704 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:30:36.91716 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:30:36.91726 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:30:36.92096 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:30:36.92181 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:30:36.92218 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:30:43.92244 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:30:43.93029 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6735665754 2016-12-01T17:30:43.93120 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6735665754 2016-12-01T17:30:43.99109 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:30:43.99130 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:30:44.04600 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:30:44.04607 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:30:44.04616 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:30:44.04627 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:30:44.04724 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:30:44.04725 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:30:44.04726 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:30:44.04726 0.03121747] 2016-12-01T17:30:44.04738 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:30:44.04747 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:30:44.04758 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:30:44.04769 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:30:44.05468 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:30:44.05912 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:30:44.06219 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:30:51.06337 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:30:51.10600 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6750231752 2016-12-01T17:30:51.10646 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6750231752 2016-12-01T17:30:51.16877 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:30:51.16904 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:30:51.19939 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:30:51.19941 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:30:51.19942 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:30:51.19942 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:30:51.19943 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:30:51.19944 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:30:51.19944 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:30:51.19945 0.03121747] 2016-12-01T17:30:51.19945 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:30:51.19945 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:30:51.19946 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:30:51.19946 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:30:51.20346 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:30:51.20732 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:30:51.20785 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:30:58.20834 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:30:58.22424 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6739524985 2016-12-01T17:30:58.22797 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6739524985 2016-12-01T17:30:58.29416 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:30:58.29429 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:30:58.33353 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:30:58.33360 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:30:58.33370 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:30:58.33379 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:30:58.33524 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:30:58.33525 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:30:58.33526 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:30:58.33526 0.03121747] 2016-12-01T17:30:58.33527 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:30:58.33527 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:30:58.33528 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:30:58.33528 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:30:58.33634 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:30:58.33698 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:30:58.33729 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:31:05.33801 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:31:05.38039 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6768227206 2016-12-01T17:31:05.38486 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6768227206 2016-12-01T17:31:05.44196 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:31:05.44361 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:31:05.47549 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:31:05.47552 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:31:05.47553 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:31:05.47553 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:31:05.47554 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:31:05.47554 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:31:05.47554 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:31:05.47555 0.03121747] 2016-12-01T17:31:05.47555 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:31:05.47556 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:31:05.47556 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:31:05.47557 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:31:05.48179 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:31:05.48244 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:31:05.48278 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:31:12.48299 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:31:12.54491 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6747171238 2016-12-01T17:31:12.54838 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6747171238 2016-12-01T17:31:12.60992 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:31:12.60994 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:31:12.97056 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:31:12.97062 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:31:12.97205 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:31:12.97206 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:31:12.97207 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:31:12.97207 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:31:12.97208 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:31:12.97208 0.03121747] 2016-12-01T17:31:12.97209 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:31:12.97209 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:31:12.97210 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:31:12.97210 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:31:12.97968 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:31:12.98038 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:31:12.98071 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:31:19.98125 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:31:20.02026 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6708280374 2016-12-01T17:31:20.02287 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6708280374 2016-12-01T17:31:20.08230 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:31:20.08242 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:31:20.10732 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:31:20.10734 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:31:20.10735 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:31:20.10735 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:31:20.10736 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:31:20.10736 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:31:20.10737 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:31:20.10737 0.03121747] 2016-12-01T17:31:20.10738 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:31:20.10738 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:31:20.10739 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:31:20.10739 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:31:20.11750 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:31:20.12007 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:31:20.12057 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:31:27.12211 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:31:27.13238 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.674531454 2016-12-01T17:31:27.13318 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.674531454 2016-12-01T17:31:27.19380 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:31:27.19382 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:31:27.21690 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:31:27.21692 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:31:27.21693 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:31:27.21693 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:31:27.21694 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:31:27.21694 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:31:27.21695 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:31:27.21695 0.03121747] 2016-12-01T17:31:27.21696 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:31:27.21696 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:31:27.21697 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:31:27.21698 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:31:27.21789 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:31:27.21946 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:31:27.21958 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:31:34.21980 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:31:34.23858 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6798950806 2016-12-01T17:31:34.23928 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6798950806 2016-12-01T17:31:34.30002 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:31:34.30019 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:31:34.32843 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:31:34.32855 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:31:34.32867 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:31:34.32877 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:31:34.32974 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:31:34.32975 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:31:34.32976 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:31:34.32976 0.03121747] 2016-12-01T17:31:34.32988 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:31:34.32999 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:31:34.33010 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:31:34.33018 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:31:34.33806 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:31:34.34336 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:31:34.34370 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:31:41.34626 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:31:41.39741 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6696720216 2016-12-01T17:31:41.39822 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6696720216 2016-12-01T17:31:41.46007 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:31:41.46010 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:31:41.48423 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:31:41.48430 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:31:41.48440 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:31:41.48675 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:31:41.48676 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:31:41.48677 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:31:41.48677 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:31:41.48678 0.03121747] 2016-12-01T17:31:41.48679 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:31:41.48679 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:31:41.48680 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:31:41.48680 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:31:41.49143 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:31:41.49572 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:31:41.49639 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:31:48.49663 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:31:48.55872 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6630561691 2016-12-01T17:31:48.56333 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6630561691 2016-12-01T17:31:48.62249 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:31:48.62270 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:31:48.65746 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:31:48.65758 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:31:48.65770 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:31:48.65781 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:31:48.65880 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:31:48.65881 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:31:48.65882 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:31:48.65883 0.03121747] 2016-12-01T17:31:48.65895 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:31:48.65905 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:31:48.65916 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:31:48.65930 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:31:48.66271 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:31:48.66337 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:31:48.66390 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:31:55.66407 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:31:55.67122 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6663138361 2016-12-01T17:31:55.67636 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6663138361 2016-12-01T17:31:55.73487 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:31:55.73489 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:31:55.77117 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:31:55.77119 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:31:55.77120 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:31:55.77121 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:31:55.77121 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:31:55.77122 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:31:55.77122 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:31:55.77123 0.03121747] 2016-12-01T17:31:55.77123 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:31:55.77124 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:31:55.77124 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:31:55.77125 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:31:55.77831 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:31:55.78082 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:31:55.78132 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:32:02.78187 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:32:02.83516 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6630439329 2016-12-01T17:32:02.83630 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6630439329 2016-12-01T17:32:02.89774 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:32:02.89777 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:32:03.39960 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:32:03.39963 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:32:03.39963 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:32:03.39964 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:32:03.39964 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:32:03.39965 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:32:03.39965 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:32:03.39966 0.03121747] 2016-12-01T17:32:03.39966 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:32:03.39967 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:32:03.39991 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:32:03.39992 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:32:03.40100 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:32:03.40166 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:32:03.40196 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:32:10.40226 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:32:10.44710 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6564216803 2016-12-01T17:32:10.44765 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6564216803 2016-12-01T17:32:10.50919 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:32:10.50930 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:32:10.57899 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:32:10.58056 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:32:10.58057 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:32:10.58058 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:32:10.58059 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:32:10.58059 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:32:10.58060 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:32:10.58060 0.03121747] 2016-12-01T17:32:10.58061 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:32:10.58061 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:32:10.58062 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:32:10.58062 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:32:10.58558 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:32:10.58941 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:32:10.59134 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:32:17.59191 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:32:17.62654 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6557603393 2016-12-01T17:32:17.62787 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6557603393 2016-12-01T17:32:17.68604 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:32:17.68616 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:32:17.99572 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:32:17.99584 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:32:17.99596 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:32:17.99607 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:32:17.99703 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:32:17.99704 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:32:17.99705 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:32:17.99706 0.03121747] 2016-12-01T17:32:17.99717 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:32:17.99728 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:32:17.99739 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:32:17.99750 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:32:18.00232 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:32:18.00846 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:32:18.00848 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:32:25.00882 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:32:25.05365 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6545497189 2016-12-01T17:32:25.05424 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6545497189 2016-12-01T17:32:25.11489 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:32:25.11491 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:32:25.14303 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:32:25.14306 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:32:25.14470 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:32:25.14700 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:32:25.14701 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:32:25.14702 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:32:25.14702 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:32:25.14703 0.03121747] 2016-12-01T17:32:25.14704 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:32:25.14705 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:32:25.14705 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:32:25.14706 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:32:25.14748 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:32:25.14801 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:32:25.14830 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:32:32.14857 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:32:32.16177 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6574105834 2016-12-01T17:32:32.16283 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6574105834 2016-12-01T17:32:32.22451 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:32:32.22463 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:32:32.26240 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:32:32.26243 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:32:32.26243 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:32:32.26244 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:32:32.26244 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:32:32.26245 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:32:32.26245 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:32:32.26246 0.03121747] 2016-12-01T17:32:32.26246 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:32:32.26247 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:32:32.26247 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:32:32.26247 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:32:32.27251 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:32:32.27545 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:32:32.27581 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:32:39.27634 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:32:39.27734 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.648904937 2016-12-01T17:32:39.27794 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.648904937 2016-12-01T17:32:39.33452 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:32:39.33455 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:32:39.36339 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:32:39.36342 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:32:39.36536 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:32:39.36537 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:32:39.36538 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:32:39.36539 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:32:39.36540 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:32:39.36540 0.03121747] 2016-12-01T17:32:39.36541 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:32:39.36541 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:32:39.36542 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:32:39.36542 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:32:39.37538 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:32:39.38088 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:32:39.38205 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:32:46.38233 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:32:46.43222 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6497749666 2016-12-01T17:32:46.43523 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6497749666 2016-12-01T17:32:46.49576 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:32:46.49579 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:32:46.55259 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:32:46.55261 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:32:46.55262 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:32:46.55262 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:32:46.55263 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:32:46.55263 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:32:46.55264 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:32:46.55264 0.03121747] 2016-12-01T17:32:46.55265 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:32:46.55265 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:32:46.55266 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:32:46.55266 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:32:46.55522 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:32:46.55573 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:32:46.55594 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:32:53.55616 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:32:53.59999 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6420514422 2016-12-01T17:32:53.60901 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6420514422 2016-12-01T17:32:53.66108 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:32:53.66110 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:32:53.69268 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:32:53.69280 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:32:53.69292 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:32:53.69305 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:32:53.69403 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:32:53.69404 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:32:53.69405 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:32:53.69405 0.03121747] 2016-12-01T17:32:53.69417 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:32:53.69427 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:32:53.69436 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:32:53.69447 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:32:53.70359 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:32:53.70446 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:32:53.70479 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:33:00.70522 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:33:00.72994 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.641835396 2016-12-01T17:33:00.73070 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.641835396 2016-12-01T17:33:00.79579 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:33:00.79582 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:33:00.82894 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:33:00.82896 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:33:00.82897 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:33:00.82897 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:33:00.82898 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:33:00.82898 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:33:00.82899 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:33:00.82899 0.03121747] 2016-12-01T17:33:00.82900 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:33:00.82900 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:33:00.82901 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:33:00.82901 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:33:00.84451 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:33:00.85064 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:33:00.85099 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:33:07.85116 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:33:07.89941 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6420349076 2016-12-01T17:33:07.90309 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6420349076 2016-12-01T17:33:07.96225 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:33:07.96227 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:33:08.14954 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:33:08.14956 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:33:08.14957 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:33:08.14957 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:33:08.14958 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:33:08.14958 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:33:08.14959 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:33:08.14959 0.03121747] 2016-12-01T17:33:08.14960 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:33:08.14960 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:33:08.14960 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:33:08.14961 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:33:08.15635 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:33:08.16033 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:33:08.16069 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:33:15.16315 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:33:15.19585 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6362253013 2016-12-01T17:33:15.19709 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6362253013 2016-12-01T17:33:15.25931 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:33:15.25933 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:33:15.34092 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:33:15.34094 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:33:15.34095 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:33:15.34095 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:33:15.34096 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:33:15.34096 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:33:15.34097 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:33:15.34097 0.03121747] 2016-12-01T17:33:15.34099 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:33:15.34107 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:33:15.34116 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:33:15.34124 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:33:15.34717 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:33:15.34780 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:33:15.34811 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:33:22.34891 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:33:22.37434 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6386300712 2016-12-01T17:33:22.37565 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6386300712 2016-12-01T17:33:22.43737 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:33:22.43739 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:33:22.54360 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:33:22.54362 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:33:22.54363 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:33:22.54363 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:33:22.54396 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:33:22.54397 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:33:22.54397 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:33:22.54398 0.03121747] 2016-12-01T17:33:22.54405 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:33:22.54412 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:33:22.54420 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:33:22.54427 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:33:22.55556 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:33:22.56660 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:33:22.56708 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:33:29.56742 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:33:29.62757 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6364238693 2016-12-01T17:33:29.62920 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6364238693 2016-12-01T17:33:29.68964 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:33:29.68966 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:33:29.77883 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:33:29.77895 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:33:29.77907 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:33:29.77920 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:33:29.78017 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:33:29.78018 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:33:29.78019 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:33:29.78019 0.03121747] 2016-12-01T17:33:29.78031 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:33:29.78041 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:33:29.78052 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:33:29.78063 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:33:29.78763 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:33:29.78829 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:33:29.78889 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:33:36.78934 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:33:36.80904 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6286350451 2016-12-01T17:33:36.80980 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6286350451 2016-12-01T17:33:36.87333 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:33:36.87348 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:33:36.93556 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:33:36.93672 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:33:36.93673 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:33:36.93674 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:33:36.93674 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:33:36.93674 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:33:36.93674 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:33:36.93675 0.03121747] 2016-12-01T17:33:36.93675 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:33:36.93675 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:33:36.93676 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:33:36.93676 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:33:36.94345 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:33:36.94849 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:33:36.94894 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:33:43.94926 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:33:43.98092 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6274737825 2016-12-01T17:33:43.98153 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6274737825 2016-12-01T17:33:44.04787 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:33:44.04790 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:33:44.08275 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:33:44.08277 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:33:44.08415 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:33:44.08417 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:33:44.08417 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:33:44.08418 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:33:44.08418 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:33:44.08419 0.03121747] 2016-12-01T17:33:44.08419 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:33:44.08420 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:33:44.08420 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:33:44.08420 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:33:44.08528 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:33:44.08586 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:33:44.08818 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:33:51.08854 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:33:51.08926 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6293469872 2016-12-01T17:33:51.09550 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6293469872 2016-12-01T17:33:51.15431 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:33:51.15433 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:33:51.19729 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:33:51.19731 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:33:51.19732 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:33:51.19733 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:33:51.19733 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:33:51.19734 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:33:51.19734 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:33:51.19735 0.03121747] 2016-12-01T17:33:51.19735 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:33:51.19736 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:33:51.19736 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:33:51.19736 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:33:51.20298 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:33:51.20427 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:33:51.20449 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:33:58.20468 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:33:58.25499 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6313289091 2016-12-01T17:33:58.25585 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6313289091 2016-12-01T17:33:58.31861 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:33:58.31864 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:33:58.38294 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:33:58.38300 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:33:58.38307 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:33:58.38314 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:33:58.38455 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:33:58.38456 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:33:58.38456 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:33:58.38457 0.03121747] 2016-12-01T17:33:58.38457 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:33:58.38458 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:33:58.38458 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:33:58.38459 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:33:58.39676 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:33:58.40576 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:33:58.40624 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:34:05.40656 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:34:05.42794 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6259143947 2016-12-01T17:34:05.42859 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6259143947 2016-12-01T17:34:05.49296 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:34:05.49298 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:34:05.52345 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:34:05.52347 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:34:05.52348 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:34:05.52349 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:34:05.52349 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:34:05.52350 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:34:05.52350 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:34:05.52351 0.03121747] 2016-12-01T17:34:05.52351 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:34:05.52352 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:34:05.52352 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:34:05.52353 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:34:05.52478 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:34:05.52545 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:34:05.52590 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:34:12.52623 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:34:12.53683 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.634688872 2016-12-01T17:34:12.53724 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.634688872 2016-12-01T17:34:12.59773 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:34:12.59805 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:34:12.62824 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:34:12.62832 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:34:12.62841 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:34:12.62850 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:34:12.62940 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:34:12.62941 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:34:12.62942 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:34:12.62942 0.03121747] 2016-12-01T17:34:12.62950 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:34:12.62957 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:34:12.62967 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:34:12.62983 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:34:12.63838 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:34:12.64168 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:34:12.64208 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:34:19.64319 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:34:19.70294 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6377981914 2016-12-01T17:34:19.70378 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6377981914 2016-12-01T17:34:19.77228 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:34:19.77231 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:34:19.80142 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:34:19.80144 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:34:19.80145 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:34:19.80145 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:34:19.80146 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:34:19.80146 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:34:19.80147 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:34:19.80147 0.03121747] 2016-12-01T17:34:19.80148 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:34:19.80148 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:34:19.80148 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:34:19.80149 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:34:19.80879 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:34:19.80926 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:34:19.80951 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:34:26.80990 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:34:26.81573 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6379396089 2016-12-01T17:34:26.82424 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6379396089 2016-12-01T17:34:26.87972 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:34:26.87975 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:34:26.91335 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:34:26.91337 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:34:26.91337 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:34:26.91338 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:34:26.91338 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:34:26.91339 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:34:26.91339 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:34:26.91341 0.03121747] 2016-12-01T17:34:26.91341 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:34:26.91342 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:34:26.91342 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:34:26.91343 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:34:26.91509 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:34:26.92402 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:34:26.92452 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:34:33.92485 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:34:33.98663 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.636480247 2016-12-01T17:34:33.98748 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.636480247 2016-12-01T17:34:34.05025 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:34:34.05028 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:34:34.07874 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:34:34.07876 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:34:34.07877 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:34:34.07877 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:34:34.07878 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:34:34.07878 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:34:34.07879 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:34:34.07879 0.03121747] 2016-12-01T17:34:34.07880 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:34:34.07880 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:34:34.07881 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:34:34.07881 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:34:34.08047 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:34:34.08101 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:34:34.08123 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:34:41.08152 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:34:41.09149 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6340786727 2016-12-01T17:34:41.09195 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6340786727 2016-12-01T17:34:41.15603 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:34:41.15623 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:34:41.18819 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:34:41.18831 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:34:41.18842 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:34:41.18852 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:34:41.18940 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:34:41.18941 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:34:41.18941 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:34:41.18941 0.03121747] 2016-12-01T17:34:41.18948 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:34:41.18955 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:34:41.18965 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:34:41.18974 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:34:41.19422 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:34:41.19485 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:34:41.19514 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:34:48.19560 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:34:48.19617 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6322606323 2016-12-01T17:34:48.20015 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6322606323 2016-12-01T17:34:48.26128 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:34:48.26130 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:34:48.46983 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:34:48.46987 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:34:48.46999 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:34:48.47003 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:34:48.47094 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:34:48.47095 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:34:48.47096 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:34:48.47096 0.03121747] 2016-12-01T17:34:48.47101 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:34:48.47121 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:34:48.47122 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:34:48.47125 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:34:48.47606 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:34:48.47703 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:34:48.47731 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:34:55.47739 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:34:55.49236 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6332910236 2016-12-01T17:34:55.49361 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6332910236 2016-12-01T17:34:55.55503 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:34:55.55505 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:34:55.58304 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:34:55.58316 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:34:55.58328 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:34:55.58338 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:34:55.58428 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:34:55.58429 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:34:55.58430 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:34:55.58430 0.03121747] 2016-12-01T17:34:55.58441 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:34:55.58450 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:34:55.58460 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:34:55.58470 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:34:55.59184 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:34:55.59237 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:34:55.59299 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:35:02.59329 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:35:02.60884 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6316668942 2016-12-01T17:35:02.61410 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6316668942 2016-12-01T17:35:02.67266 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:35:02.67268 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:35:03.08117 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:35:03.08119 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:35:03.08120 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:35:03.08120 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:35:03.08121 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:35:03.08121 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:35:03.08122 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:35:03.08122 0.03121747] 2016-12-01T17:35:03.08123 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:35:03.08123 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:35:03.08124 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:35:03.08124 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:35:03.08158 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:35:03.08229 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:35:03.08260 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:35:10.08293 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:35:10.11308 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6281745297 2016-12-01T17:35:10.11700 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6281745297 2016-12-01T17:35:10.19086 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:35:10.19089 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:35:10.21310 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:35:10.21313 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:35:10.21313 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:35:10.21313 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:35:10.21314 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:35:10.21314 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:35:10.21315 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:35:10.21315 0.03121747] 2016-12-01T17:35:10.21316 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:35:10.21316 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:35:10.21316 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:35:10.21317 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:35:10.23124 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:35:10.23127 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:35:10.23127 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:35:17.23188 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:35:17.24093 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6350728786 2016-12-01T17:35:17.24148 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6350728786 2016-12-01T17:35:17.30402 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:35:17.30404 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:35:17.32920 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:35:17.32923 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:35:17.32923 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:35:17.32924 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:35:17.33006 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:35:17.33007 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:35:17.33008 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:35:17.33009 0.03121747] 2016-12-01T17:35:17.33016 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:35:17.33053 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:35:17.33054 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:35:17.33054 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:35:17.33192 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:35:17.33258 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:35:17.33273 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:35:24.33308 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:35:24.33970 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6375219574 2016-12-01T17:35:24.34041 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6375219574 2016-12-01T17:35:24.40414 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:35:24.40418 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:35:24.43695 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:35:24.43698 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:35:24.43698 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:35:24.43699 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:35:24.43699 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:35:24.43700 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:35:24.43700 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:35:24.43701 0.03121747] 2016-12-01T17:35:24.43701 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:35:24.43702 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:35:24.43702 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:35:24.43703 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:35:24.44604 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:35:24.44697 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:35:24.44746 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:35:31.44767 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:35:31.46850 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6342429296 2016-12-01T17:35:31.46907 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6342429296 2016-12-01T17:35:31.53215 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:35:31.53235 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:35:31.55944 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:35:31.55950 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:35:31.55961 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:35:31.55966 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:35:31.56051 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:35:31.56052 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:35:31.56052 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:35:31.56053 0.03121747] 2016-12-01T17:35:31.56063 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:35:31.56071 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:35:31.56081 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:35:31.56090 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:35:31.56196 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:35:31.56298 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:35:31.56321 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:35:38.56335 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:35:38.57625 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6308677987 2016-12-01T17:35:38.57987 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6308677987 2016-12-01T17:35:38.64085 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:35:38.64088 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:35:38.67463 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:35:38.67465 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:35:38.67466 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:35:38.67466 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:35:38.67467 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:35:38.67467 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:35:38.67467 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:35:38.67468 0.03121747] 2016-12-01T17:35:38.67469 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:35:38.67475 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:35:38.67506 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:35:38.67507 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:35:38.67702 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:35:38.68255 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:35:38.68291 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:35:45.68327 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:35:45.74575 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6355562358 2016-12-01T17:35:45.74989 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6355562358 2016-12-01T17:35:45.80341 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:35:45.80356 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:35:45.83517 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:35:45.83520 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:35:45.83521 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:35:45.83521 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:35:45.83522 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:35:45.83522 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:35:45.83523 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:35:45.83523 0.03121747] 2016-12-01T17:35:45.83524 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:35:45.83524 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:35:45.83525 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:35:45.83525 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:35:45.84720 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:35:45.84788 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:35:45.84839 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:35:52.84872 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:35:52.85103 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6275143817 2016-12-01T17:35:52.85173 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6275143817 2016-12-01T17:35:52.91642 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:35:52.91654 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:35:53.23943 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:35:53.23952 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:35:53.23964 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:35:53.23968 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:35:53.24062 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:35:53.24064 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:35:53.24064 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:35:53.24065 0.03121747] 2016-12-01T17:35:53.24065 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:35:53.24091 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:35:53.24092 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:35:53.24092 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:35:53.24544 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:35:53.24648 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:35:53.24662 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:36:00.24697 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:36:00.27166 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6391085749 2016-12-01T17:36:00.27245 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6391085749 2016-12-01T17:36:00.32957 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:36:00.32978 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:36:00.36066 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:36:00.36078 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:36:00.36090 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:36:00.36101 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:36:00.36197 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:36:00.36198 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:36:00.36199 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:36:00.36200 0.03121747] 2016-12-01T17:36:00.36212 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:36:00.36223 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:36:00.36234 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:36:00.36246 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:36:00.36469 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:36:00.36534 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:36:00.36571 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:36:07.36663 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:36:07.37640 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6292176004 2016-12-01T17:36:07.37997 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6292176004 2016-12-01T17:36:07.43747 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:36:07.43749 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:36:07.47383 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:36:07.47385 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:36:07.47385 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:36:07.47386 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:36:07.47393 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:36:07.47394 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:36:07.47395 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:36:07.47395 0.03121747] 2016-12-01T17:36:07.47408 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:36:07.47420 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:36:07.47432 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:36:07.47443 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:36:07.48400 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:36:07.48759 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:36:07.48795 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:36:14.49123 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:36:14.54043 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6323318363 2016-12-01T17:36:14.54117 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6323318363 2016-12-01T17:36:14.60357 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:36:14.60359 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:36:14.63081 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:36:14.63083 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:36:14.63084 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:36:14.63084 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:36:14.63085 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:36:14.63085 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:36:14.63086 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:36:14.63086 0.03121747] 2016-12-01T17:36:14.63088 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:36:14.63088 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:36:14.63089 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:36:14.63089 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:36:14.64545 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:36:14.65603 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:36:14.65653 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:36:21.65843 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:36:21.66102 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6310280814 2016-12-01T17:36:21.66799 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6310280814 2016-12-01T17:36:21.72146 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:36:21.72148 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:36:21.75573 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:36:21.75575 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:36:21.75575 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:36:21.75576 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:36:21.75576 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:36:21.75577 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:36:21.75577 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:36:21.75578 0.03121747] 2016-12-01T17:36:21.75578 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:36:21.75578 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:36:21.75579 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:36:21.75579 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:36:21.75679 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:36:21.75743 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:36:21.75793 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:36:28.75860 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:36:28.76977 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6327878412 2016-12-01T17:36:28.77141 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6327878412 2016-12-01T17:36:28.83207 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:36:28.83220 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:36:28.86002 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:36:28.86005 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:36:28.86005 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:36:28.86006 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:36:28.86006 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:36:28.86008 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:36:28.86009 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:36:28.86009 0.03121747] 2016-12-01T17:36:28.86010 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:36:28.86010 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:36:28.86011 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:36:28.86011 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:36:28.86163 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:36:28.86375 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:36:28.86408 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:36:35.86458 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:36:35.87951 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6276240852 2016-12-01T17:36:35.87953 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6276240852 2016-12-01T17:36:35.94170 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:36:35.94172 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:36:35.96619 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:36:35.96623 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:36:35.96632 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:36:35.96640 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:36:35.96741 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:36:35.96742 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:36:35.96743 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:36:35.96743 0.03121747] 2016-12-01T17:36:35.96751 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:36:35.96758 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:36:35.96767 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:36:35.96775 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:36:35.97431 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:36:35.98217 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:36:35.98773 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:36:42.98707 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:36:42.99418 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6269722098 2016-12-01T17:36:42.99870 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6269722098 2016-12-01T17:36:43.05710 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:36:43.05712 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:36:43.10978 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:36:43.10985 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:36:43.10994 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:36:43.11003 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:36:43.11476 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:36:43.11478 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:36:43.11478 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:36:43.11479 0.03121747] 2016-12-01T17:36:43.11479 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:36:43.11480 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:36:43.11480 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:36:43.11480 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:36:43.11786 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:36:43.11879 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:36:43.11921 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:36:50.12122 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:36:50.17463 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6284308672 2016-12-01T17:36:50.17679 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6284308672 2016-12-01T17:36:50.23876 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:36:50.23879 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:36:50.27710 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:36:50.27716 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:36:50.27724 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:36:50.27730 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:36:50.27857 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:36:50.27858 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:36:50.27859 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:36:50.27859 0.03121747] 2016-12-01T17:36:50.27860 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:36:50.27860 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:36:50.27861 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:36:50.27861 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:36:50.28014 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:36:50.28086 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:36:50.28130 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:36:57.28175 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:36:57.28568 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6347183606 2016-12-01T17:36:57.28817 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6347183606 2016-12-01T17:36:57.34762 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:36:57.34764 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:36:57.38023 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:36:57.38025 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:36:57.38025 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:36:57.38026 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:36:57.38026 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:36:57.38027 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:36:57.38027 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:36:57.38027 0.03121747] 2016-12-01T17:36:57.38028 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:36:57.38028 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:36:57.38029 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:36:57.38029 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:36:57.39232 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:36:57.40339 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:36:57.40367 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:37:04.40397 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:37:04.45807 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.628434335 2016-12-01T17:37:04.45875 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.628434335 2016-12-01T17:37:04.52185 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:37:04.52205 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:37:04.54781 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:37:04.54788 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:37:04.54797 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:37:04.54804 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:37:04.54854 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:37:04.54854 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:37:04.54855 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:37:04.54856 0.03121747] 2016-12-01T17:37:04.54861 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:37:04.54866 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:37:04.54872 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:37:04.54878 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:37:04.55310 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:37:04.55477 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:37:04.55503 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:37:11.55766 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:37:11.56442 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6327197622 2016-12-01T17:37:11.56581 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6327197622 2016-12-01T17:37:11.62803 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:37:11.62805 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:37:11.65960 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:37:11.65967 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:37:11.65976 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:37:11.65984 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:37:11.66084 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:37:11.66085 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:37:11.66085 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:37:11.66086 0.03121747] 2016-12-01T17:37:11.66095 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:37:11.66103 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:37:11.66144 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:37:11.66146 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:37:11.66552 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:37:11.66763 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:37:11.66941 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:37:18.66971 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:37:18.69057 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6344131348 2016-12-01T17:37:18.69138 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6344131348 2016-12-01T17:37:18.75306 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:37:18.75318 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:37:18.78861 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:37:18.78863 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:37:18.78864 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:37:18.78864 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:37:18.79001 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:37:18.79003 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:37:18.79003 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:37:18.79004 0.03121747] 2016-12-01T17:37:18.79004 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:37:18.79005 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:37:18.79005 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:37:18.79006 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:37:18.79481 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:37:18.80022 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:37:18.80024 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:37:25.80069 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:37:25.85728 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.634811303 2016-12-01T17:37:25.86203 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.634811303 2016-12-01T17:37:25.92152 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:37:25.92155 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:37:25.94752 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:37:25.94754 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:37:25.94754 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:37:25.94755 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:37:25.94755 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:37:25.94756 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:37:25.94756 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:37:25.94757 0.03121747] 2016-12-01T17:37:25.94757 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:37:25.94758 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:37:25.94758 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:37:25.94758 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:37:25.95547 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:37:25.96339 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:37:25.96362 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:37:32.96405 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:37:32.97754 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6361048866 2016-12-01T17:37:32.97831 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6361048866 2016-12-01T17:37:33.04048 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:37:33.04074 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:37:33.14068 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:37:33.14070 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:37:33.14071 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:37:33.14071 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:37:33.14109 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:37:33.14110 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:37:33.14110 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:37:33.14111 0.03121747] 2016-12-01T17:37:33.14115 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:37:33.14125 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:37:33.14132 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:37:33.14139 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:37:33.14237 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:37:33.14357 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:37:33.14378 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:37:40.14697 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:37:40.15037 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6321936393 2016-12-01T17:37:40.15575 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6321936393 2016-12-01T17:37:40.21047 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:37:40.21049 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:37:40.24026 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:37:40.24032 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:37:40.24039 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:37:40.24045 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:37:40.24107 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:37:40.24108 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:37:40.24109 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:37:40.24109 0.03121747] 2016-12-01T17:37:40.24122 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:37:40.24131 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:37:40.24143 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:37:40.24158 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:37:40.24360 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:37:40.24813 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:37:40.24858 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:37:47.24891 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:37:47.26767 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6314403835 2016-12-01T17:37:47.27561 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6314403835 2016-12-01T17:37:47.32399 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:37:47.32402 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:37:47.35492 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:37:47.35495 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:37:47.35495 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:37:47.35496 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:37:47.35496 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:37:47.35497 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:37:47.35497 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:37:47.35498 0.03121747] 2016-12-01T17:37:47.35498 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:37:47.35499 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:37:47.35499 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:37:47.35500 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:37:47.35882 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:37:47.36493 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:37:47.36533 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:37:54.36521 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:37:54.38908 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6332437747 2016-12-01T17:37:54.38965 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6332437747 2016-12-01T17:37:54.45208 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:37:54.45210 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:37:54.48228 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:37:54.48230 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:37:54.48231 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:37:54.48232 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:37:54.48232 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:37:54.48233 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:37:54.48233 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:37:54.48234 0.03121747] 2016-12-01T17:37:54.48234 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:37:54.48234 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:37:54.48235 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:37:54.48235 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:37:54.48449 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:37:54.48518 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:37:54.48548 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:38:01.48847 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:38:01.50111 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6356357292 2016-12-01T17:38:01.50375 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6356357292 2016-12-01T17:38:01.56204 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:38:01.56213 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:38:01.59637 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:38:01.59644 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:38:01.59653 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:38:01.59662 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:38:01.59752 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:38:01.59753 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:38:01.59754 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:38:01.59754 0.03121747] 2016-12-01T17:38:01.59766 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:38:01.59776 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:38:01.59788 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:38:01.59798 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:38:01.62399 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:38:01.64002 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:38:01.64262 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:38:08.64352 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:38:08.67277 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6370700526 2016-12-01T17:38:08.67750 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6370700526 2016-12-01T17:38:08.74091 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:38:08.74110 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:38:08.77353 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:38:08.77355 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:38:08.77356 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:38:08.77356 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:38:08.77357 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:38:08.77357 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:38:08.77358 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:38:08.77358 0.03121747] 2016-12-01T17:38:08.77359 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:38:08.77359 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:38:08.77360 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:38:08.77360 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:38:08.77721 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:38:08.78920 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:38:08.79327 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:38:15.79469 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:38:15.85085 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6392073187 2016-12-01T17:38:15.85335 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6392073187 2016-12-01T17:38:15.91622 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:38:15.91625 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:38:15.96503 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:38:15.96505 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:38:15.96506 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:38:15.96506 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:38:15.96507 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:38:15.96507 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:38:15.96508 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:38:15.96510 0.03121747] 2016-12-01T17:38:15.96510 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:38:15.96511 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:38:15.96511 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:38:15.96511 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:38:15.96641 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:38:15.96706 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:38:15.96886 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:38:22.96933 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:38:23.01745 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6380733065 2016-12-01T17:38:23.02680 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6380733065 2016-12-01T17:38:23.08049 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:38:23.08051 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:38:23.24942 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:38:23.24945 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:38:23.24945 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:38:23.24946 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:38:23.24946 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:38:23.24947 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:38:23.24947 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:38:23.24948 0.03121747] 2016-12-01T17:38:23.24951 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:38:23.24957 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:38:23.24969 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:38:23.24979 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:38:23.26119 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:38:23.26610 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:38:23.26715 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:38:30.27004 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:38:30.30088 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6349211193 2016-12-01T17:38:30.30160 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6349211193 2016-12-01T17:38:30.36448 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:38:30.36463 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:38:30.39803 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:38:30.39809 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:38:30.39816 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:38:30.39822 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:38:30.39908 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:38:30.39909 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:38:30.39909 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:38:30.39910 0.03121747] 2016-12-01T17:38:30.39923 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:38:30.39932 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:38:30.39943 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:38:30.39953 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:38:30.40139 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:38:30.40271 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:38:30.40314 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:38:37.40359 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:38:37.41130 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6371698642 2016-12-01T17:38:37.41187 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6371698642 2016-12-01T17:38:37.47183 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:38:37.47185 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:38:37.51637 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:38:37.51638 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:38:37.51639 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:38:37.51639 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:38:37.51743 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:38:37.51744 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:38:37.51745 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:38:37.51745 0.03121747] 2016-12-01T17:38:37.51746 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:38:37.51746 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:38:37.51747 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:38:37.51747 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:38:37.52934 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:38:37.53132 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:38:37.53180 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:38:44.53227 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:38:44.58064 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6437551823 2016-12-01T17:38:44.58219 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6437551823 2016-12-01T17:38:44.64474 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:38:44.64476 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:38:44.68115 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:38:44.68118 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:38:44.68119 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:38:44.68119 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:38:44.68120 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:38:44.68120 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:38:44.68121 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:38:44.68121 0.03121747] 2016-12-01T17:38:44.68122 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:38:44.68122 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:38:44.68123 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:38:44.68123 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:38:44.68309 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:38:44.68386 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:38:44.68414 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:38:51.68468 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:38:51.69194 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6389570081 2016-12-01T17:38:51.69268 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6389570081 2016-12-01T17:38:51.75299 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:38:51.75301 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:38:51.78199 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:38:51.78327 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:38:51.78329 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:38:51.78330 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:38:51.78330 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:38:51.78331 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:38:51.78331 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:38:51.78332 0.03121747] 2016-12-01T17:38:51.78333 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:38:51.78364 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:38:51.78365 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:38:51.78366 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:38:51.78477 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:38:51.78558 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:38:51.78590 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:38:58.78639 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:38:58.80510 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6431460316 2016-12-01T17:38:58.80579 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6431460316 2016-12-01T17:38:58.87238 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:38:58.87240 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:38:58.92437 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:38:58.92442 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:38:58.92600 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:38:58.92601 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:38:58.92602 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:38:58.92602 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:38:58.92603 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:38:58.92603 0.03121747] 2016-12-01T17:38:58.92604 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:38:58.92604 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:38:58.92605 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:38:58.92605 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:38:58.93589 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:38:58.93643 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:38:58.93668 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:39:05.93690 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:39:05.98551 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6378598603 2016-12-01T17:39:05.98830 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6378598603 2016-12-01T17:39:06.05077 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:39:06.05079 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:39:06.08469 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:39:06.08471 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:39:06.08472 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:39:06.08472 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:39:06.08473 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:39:06.08473 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:39:06.08474 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:39:06.08474 0.03121747] 2016-12-01T17:39:06.08475 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:39:06.08475 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:39:06.08475 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:39:06.08476 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:39:06.09011 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:39:06.09080 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:39:06.09111 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:39:13.09174 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:39:13.10130 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6429854925 2016-12-01T17:39:13.10349 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6429854925 2016-12-01T17:39:13.16436 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:39:13.16440 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:39:13.19861 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:39:13.19863 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:39:13.19864 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:39:13.19864 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:39:13.19865 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:39:13.19865 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:39:13.19866 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:39:13.19866 0.03121747] 2016-12-01T17:39:13.19866 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:39:13.19867 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:39:13.19867 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:39:13.19868 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:39:13.21143 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:39:13.21963 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:39:13.21995 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:39:20.22321 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:39:20.27963 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6432305156 2016-12-01T17:39:20.28117 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6432305156 2016-12-01T17:39:20.33492 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:39:20.33508 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:39:20.35840 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:39:20.35850 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:39:20.35859 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:39:20.35868 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:39:20.35963 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:39:20.35964 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:39:20.35965 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:39:20.35965 0.03121747] 2016-12-01T17:39:20.35973 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:39:20.35980 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:39:20.35989 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:39:20.35997 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:39:20.36810 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:39:20.37274 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:39:20.37298 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:39:27.37334 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:39:27.39368 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6440525922 2016-12-01T17:39:27.40020 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6440525922 2016-12-01T17:39:27.45181 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:39:27.45183 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:39:27.47831 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:39:27.47833 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:39:27.47834 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:39:27.47834 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:39:27.47904 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:39:27.47905 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:39:27.47905 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:39:27.47906 0.03121747] 2016-12-01T17:39:27.47912 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:39:27.47918 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:39:27.47925 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:39:27.47933 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:39:27.48191 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:39:27.48608 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:39:27.48637 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:39:34.48710 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:39:34.49970 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6460520866 2016-12-01T17:39:34.50092 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6460520866 2016-12-01T17:39:34.56130 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:39:34.56143 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:39:34.60131 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:39:34.60132 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:39:34.60132 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:39:34.60133 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:39:34.60133 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:39:34.60133 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:39:34.60134 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:39:34.60134 0.03121747] 2016-12-01T17:39:34.60134 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:39:34.60135 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:39:34.60135 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:39:34.60135 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:39:34.60662 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:39:34.60733 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:39:34.60764 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:39:41.60882 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:39:41.66470 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6557995079 2016-12-01T17:39:41.66649 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6557995079 2016-12-01T17:39:41.72658 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:39:41.72671 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:39:41.76632 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:39:41.76635 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:39:41.76635 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:39:41.76643 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:39:41.76904 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:39:41.76905 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:39:41.76906 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:39:41.76906 0.03121747] 2016-12-01T17:39:41.76907 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:39:41.76907 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:39:41.76908 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:39:41.76908 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:39:41.77635 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:39:41.78185 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:39:41.78220 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:39:48.78280 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:39:48.83260 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.65601178 2016-12-01T17:39:48.83313 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.65601178 2016-12-01T17:39:48.90194 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:39:48.90206 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:39:48.93969 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:39:48.93978 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:39:48.93987 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:39:48.93999 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:39:48.94094 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:39:48.94095 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:39:48.94095 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:39:48.94096 0.03121747] 2016-12-01T17:39:48.94108 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:39:48.94118 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:39:48.94128 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:39:48.94139 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:39:48.94885 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:39:48.95009 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:39:48.95031 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:39:55.95163 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:39:55.99067 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6513202397 2016-12-01T17:39:55.99397 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6513202397 2016-12-01T17:39:56.05478 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:39:56.05489 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:39:56.11538 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:39:56.11541 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:39:56.11541 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:39:56.11542 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:39:56.11542 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:39:56.11543 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:39:56.11543 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:39:56.11544 0.03121747] 2016-12-01T17:39:56.11544 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:39:56.11545 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:39:56.11639 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:39:56.11640 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:39:56.11812 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:39:56.11897 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:39:56.11948 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:40:03.12022 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:40:03.17968 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6591310326 2016-12-01T17:40:03.18197 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6591310326 2016-12-01T17:40:03.24420 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:40:03.24435 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:40:03.32469 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:40:03.32471 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:40:03.32472 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:40:03.32472 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:40:03.32473 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:40:03.32473 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:40:03.32474 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:40:03.32474 0.03121747] 2016-12-01T17:40:03.32475 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:40:03.32477 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:40:03.32477 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:40:03.32478 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:40:03.33049 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:40:03.33113 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:40:03.33145 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:40:10.33168 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:40:10.36416 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6587079905 2016-12-01T17:40:10.36736 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6587079905 2016-12-01T17:40:10.42734 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:40:10.42736 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:40:10.45221 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:40:10.45223 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:40:10.45224 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:40:10.45224 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:40:10.45225 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:40:10.45225 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:40:10.45226 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:40:10.45226 0.03121747] 2016-12-01T17:40:10.45227 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:40:10.45227 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:40:10.45227 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:40:10.45228 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:40:10.45662 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:40:10.45782 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:40:10.45832 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:40:17.45880 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:40:17.46259 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6610692294 2016-12-01T17:40:17.46309 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6610692294 2016-12-01T17:40:17.52993 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:40:17.53009 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:40:17.56203 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:40:17.56205 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:40:17.56205 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:40:17.56206 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:40:17.56254 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:40:17.56256 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:40:17.56257 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:40:17.56257 0.03121747] 2016-12-01T17:40:17.56263 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:40:17.56269 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:40:17.56276 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:40:17.56283 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:40:17.57037 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:40:17.57109 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:40:17.57190 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:40:24.57218 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:40:24.63345 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6584063716 2016-12-01T17:40:24.63416 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6584063716 2016-12-01T17:40:24.69487 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:40:24.69517 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:40:24.71855 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:40:24.71857 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:40:24.71858 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:40:24.71858 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:40:24.71918 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:40:24.71921 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:40:24.71922 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:40:24.71922 0.03121747] 2016-12-01T17:40:24.71923 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:40:24.71923 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:40:24.71924 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:40:24.71924 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:40:24.72490 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:40:24.72560 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:40:24.72595 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:40:31.72794 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:40:31.73414 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6582416226 2016-12-01T17:40:31.74398 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6582416226 2016-12-01T17:40:31.79848 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:40:31.79851 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:40:31.85351 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:40:31.85357 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:40:31.85364 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:40:31.85371 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:40:31.85424 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:40:31.85425 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:40:31.85426 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:40:31.85426 0.03121747] 2016-12-01T17:40:31.85432 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:40:31.85438 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:40:31.85444 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:40:31.85451 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:40:31.85946 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:40:31.86000 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:40:31.86062 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:40:38.86245 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:40:38.89202 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6574337661 2016-12-01T17:40:38.89269 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6574337661 2016-12-01T17:40:38.95373 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:40:38.95389 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:40:38.98372 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:40:38.98384 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:40:38.98396 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:40:38.98407 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:40:38.98504 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:40:38.98505 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:40:38.98506 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:40:38.98506 0.03121747] 2016-12-01T17:40:38.98518 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:40:38.98528 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:40:38.98540 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:40:38.98551 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:40:38.99335 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:40:38.99538 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:40:38.99580 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:40:45.99612 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:40:46.00119 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6653451815 2016-12-01T17:40:46.00665 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6653451815 2016-12-01T17:40:46.06182 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:40:46.06184 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:40:46.09495 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:40:46.09507 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:40:46.09518 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:40:46.09534 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:40:46.09631 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:40:46.09632 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:40:46.09632 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:40:46.09633 0.03121747] 2016-12-01T17:40:46.09644 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:40:46.09654 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:40:46.09666 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:40:46.09676 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:40:46.09776 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:40:46.09837 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:40:46.09859 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:40:53.09956 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:40:53.15611 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6677650305 2016-12-01T17:40:53.15684 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6677650305 2016-12-01T17:40:53.21960 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:40:53.21976 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:40:53.27752 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:40:53.27763 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:40:53.27775 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:40:53.27786 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:40:53.27883 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:40:53.27885 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:40:53.27885 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:40:53.27886 0.03121747] 2016-12-01T17:40:53.27897 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:40:53.27907 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:40:53.27914 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:40:53.27921 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:40:53.28351 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:40:53.28418 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:40:53.28447 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:41:00.28690 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:41:00.32348 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6603206433 2016-12-01T17:41:00.32425 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6603206433 2016-12-01T17:41:00.38654 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:41:00.38657 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:41:00.43133 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:41:00.43135 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:41:00.43136 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:41:00.43136 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:41:00.43221 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:41:00.43222 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:41:00.43222 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:41:00.43223 0.03121747] 2016-12-01T17:41:00.43223 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:41:00.43224 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:41:00.43224 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:41:00.43225 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:41:00.43331 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:41:00.43404 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:41:00.43475 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:41:07.43557 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:41:07.48361 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.664177313 2016-12-01T17:41:07.48415 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.664177313 2016-12-01T17:41:07.54569 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:41:07.54571 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:41:07.56741 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:41:07.56743 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:41:07.56744 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:41:07.56744 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:41:07.56745 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:41:07.56745 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:41:07.56745 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:41:07.56746 0.03121747] 2016-12-01T17:41:07.56746 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:41:07.56747 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:41:07.56747 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:41:07.56748 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:41:07.56907 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:41:07.57452 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:41:07.57607 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:41:14.57499 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:41:14.58441 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6614240955 2016-12-01T17:41:14.58700 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6614240955 2016-12-01T17:41:14.64738 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:41:14.64740 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:41:14.67862 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:41:14.67865 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:41:14.67951 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:41:14.67952 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:41:14.68020 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:41:14.68021 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:41:14.68022 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:41:14.68023 0.03121747] 2016-12-01T17:41:14.68023 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:41:14.68024 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:41:14.68024 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:41:14.68025 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:41:14.68145 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:41:14.68209 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:41:14.68239 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:41:21.68317 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:41:21.74201 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6623232985 2016-12-01T17:41:21.74457 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6623232985 2016-12-01T17:41:21.80544 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:41:21.80559 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:41:21.83397 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:41:21.83399 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:41:21.83399 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:41:21.83400 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:41:21.83400 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:41:21.83401 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:41:21.83401 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:41:21.83402 0.03121747] 2016-12-01T17:41:21.83402 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:41:21.83403 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:41:21.83403 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:41:21.83404 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:41:21.83493 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:41:21.83555 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:41:21.83600 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:41:28.83633 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:41:28.85789 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6647176349 2016-12-01T17:41:28.85902 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6647176349 2016-12-01T17:41:28.91424 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:41:28.91426 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:41:28.95139 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:41:28.95282 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:41:28.95284 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:41:28.95285 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:41:28.95285 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:41:28.95286 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:41:28.95286 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:41:28.95287 0.03121747] 2016-12-01T17:41:28.95287 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:41:28.95287 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:41:28.95288 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:41:28.95288 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:41:28.95664 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:41:28.95725 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:41:28.95752 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:41:35.95790 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:41:35.95926 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6644582961 2016-12-01T17:41:35.96048 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6644582961 2016-12-01T17:41:36.02308 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:41:36.02330 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:41:36.05113 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:41:36.05126 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:41:36.05139 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:41:36.05150 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:41:36.05245 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:41:36.05246 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:41:36.05247 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:41:36.05247 0.03121747] 2016-12-01T17:41:36.05259 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:41:36.05269 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:41:36.05280 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:41:36.05290 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:41:36.06125 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:41:36.06495 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:41:36.06747 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:41:43.06764 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:41:43.07210 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6677771885 2016-12-01T17:41:43.07691 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6677771885 2016-12-01T17:41:43.13705 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:41:43.13707 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:41:43.37895 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:41:43.37901 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:41:43.37908 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:41:43.37915 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:41:43.37972 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:41:43.37974 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:41:43.37974 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:41:43.37975 0.03121747] 2016-12-01T17:41:43.37980 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:41:43.37986 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:41:43.38013 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:41:43.38014 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:41:43.38156 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:41:43.38221 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:41:43.38377 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:41:50.38411 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:41:50.42067 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6648071981 2016-12-01T17:41:50.42132 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6648071981 2016-12-01T17:41:50.48199 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:41:50.48215 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:41:50.51210 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:41:50.51213 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:41:50.51213 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:41:50.51214 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:41:50.51215 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:41:50.51216 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:41:50.51216 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:41:50.51217 0.03121747] 2016-12-01T17:41:50.51217 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:41:50.51218 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:41:50.51220 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:41:50.51220 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:41:50.51819 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:41:50.51885 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:41:50.51915 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:41:57.51961 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:41:57.54172 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6686973856 2016-12-01T17:41:57.54350 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6686973856 2016-12-01T17:41:57.60086 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:41:57.60099 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:41:57.63655 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:41:57.63656 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:41:57.63657 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:41:57.63657 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:41:57.63658 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:41:57.63658 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:41:57.63659 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:41:57.63659 0.03121747] 2016-12-01T17:41:57.63660 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:41:57.63660 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:41:57.63661 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:41:57.63661 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:41:57.64629 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:41:57.65224 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:41:57.65273 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:42:04.65527 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:42:04.70723 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6647276245 2016-12-01T17:42:04.70861 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6647276245 2016-12-01T17:42:04.77138 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:42:04.77140 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:42:04.80940 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:42:04.80946 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:42:04.80954 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:42:04.80961 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:42:04.81014 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:42:04.81015 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:42:04.81016 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:42:04.81017 0.03121747] 2016-12-01T17:42:04.81022 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:42:04.81028 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:42:04.81035 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:42:04.81041 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:42:04.81409 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:42:04.81475 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:42:04.81499 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:42:11.81627 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:42:11.87465 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6677895024 2016-12-01T17:42:11.87750 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6677895024 2016-12-01T17:42:11.93848 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:42:11.93850 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:42:11.96003 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:42:11.96011 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:42:11.96019 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:42:11.96027 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:42:11.96117 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:42:11.96118 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:42:11.96118 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:42:11.96119 0.03121747] 2016-12-01T17:42:11.96125 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:42:11.96133 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:42:11.96141 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:42:11.96149 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:42:11.96832 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:42:11.97320 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:42:11.97645 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:42:18.97636 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:42:19.03814 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6641117447 2016-12-01T17:42:19.03973 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6641117447 2016-12-01T17:42:19.09845 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:42:19.09859 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:42:19.13282 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:42:19.13284 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:42:19.13284 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:42:19.13285 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:42:19.13285 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:42:19.13287 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:42:19.13288 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:42:19.13288 0.03121747] 2016-12-01T17:42:19.13289 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:42:19.13289 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:42:19.13290 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:42:19.13290 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:42:19.13945 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:42:19.14236 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:42:19.14261 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:42:26.14350 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:42:26.15986 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6774644209 2016-12-01T17:42:26.16740 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6774644209 2016-12-01T17:42:26.22210 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:42:26.22226 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:42:26.25523 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:42:26.25535 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:42:26.25547 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:42:26.25558 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:42:26.25654 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:42:26.25655 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:42:26.25656 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:42:26.25657 0.03121747] 2016-12-01T17:42:26.25958 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:42:26.25969 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:42:26.25980 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:42:26.25990 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:42:26.26996 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:42:26.27069 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:42:26.27414 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:42:33.27400 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:42:33.32632 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6730586458 2016-12-01T17:42:33.32722 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6730586458 2016-12-01T17:42:33.39013 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:42:33.39047 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:42:33.45759 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:42:33.45764 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:42:33.45764 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:42:33.45765 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:42:33.45849 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:42:33.45850 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:42:33.45851 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:42:33.45852 0.03121747] 2016-12-01T17:42:33.45858 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:42:33.45868 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:42:33.45877 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:42:33.45881 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:42:33.45993 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:42:33.46064 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:42:33.46106 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:42:40.46418 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:42:40.50430 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.676235747 2016-12-01T17:42:40.50842 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.676235747 2016-12-01T17:42:40.56782 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:42:40.56799 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:42:40.59413 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:42:40.59419 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:42:40.59426 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:42:40.59434 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:42:40.59487 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:42:40.59488 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:42:40.59489 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:42:40.59489 0.03121747] 2016-12-01T17:42:40.59495 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:42:40.59501 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:42:40.59532 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:42:40.59533 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:42:40.59934 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:42:40.60059 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:42:40.60089 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:42:47.60108 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:42:47.61623 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6807064905 2016-12-01T17:42:47.62047 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6807064905 2016-12-01T17:42:47.68656 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:42:47.68684 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:42:47.78652 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:42:47.78654 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:42:47.78655 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:42:47.78655 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:42:47.78713 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:42:47.78714 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:42:47.78715 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:42:47.78715 0.03121747] 2016-12-01T17:42:47.78716 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:42:47.78716 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:42:47.78717 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:42:47.78717 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:42:47.79961 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:42:47.80122 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:42:47.80145 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:42:54.80170 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:42:54.83822 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.678761354 2016-12-01T17:42:54.83884 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.678761354 2016-12-01T17:42:54.90140 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:42:54.90143 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:42:54.93022 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:42:54.93024 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:42:54.93024 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:42:54.93025 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:42:54.93025 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:42:54.93026 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:42:54.93026 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:42:54.93027 0.03121747] 2016-12-01T17:42:54.93027 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:42:54.93028 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:42:54.93028 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:42:54.93029 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:42:54.94180 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:42:54.94711 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:42:54.95122 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:43:01.95150 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:43:02.01126 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6776751047 2016-12-01T17:43:02.02029 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6776751047 2016-12-01T17:43:02.07586 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:43:02.07590 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:43:02.10184 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:43:02.10192 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:43:02.10204 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:43:02.10208 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:43:02.10305 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:43:02.10305 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:43:02.10306 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:43:02.10307 0.03121747] 2016-12-01T17:43:02.10312 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:43:02.10349 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:43:02.10350 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:43:02.10351 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:43:02.11109 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:43:02.11662 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:43:02.11742 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:43:09.11936 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:43:09.17256 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6821193769 2016-12-01T17:43:09.17526 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6821193769 2016-12-01T17:43:09.23454 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:43:09.23471 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:43:09.26856 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:43:09.26858 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:43:09.26858 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:43:09.26859 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:43:09.26915 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:43:09.26916 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:43:09.26916 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:43:09.26917 0.03121747] 2016-12-01T17:43:09.26917 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:43:09.26918 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:43:09.26918 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:43:09.26919 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:43:09.27158 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:43:09.27694 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:43:09.27723 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:43:16.27952 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:43:16.28095 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6759805324 2016-12-01T17:43:16.28249 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6759805324 2016-12-01T17:43:16.34089 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:43:16.34105 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:43:16.38310 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:43:16.38312 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:43:16.38312 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:43:16.38313 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:43:16.38314 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:43:16.38314 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:43:16.38315 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:43:16.38315 0.03121747] 2016-12-01T17:43:16.38315 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:43:16.38317 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:43:16.38348 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:43:16.38350 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:43:16.39304 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:43:16.39728 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:43:16.39758 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:43:23.39915 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:43:23.45418 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6836486314 2016-12-01T17:43:23.45494 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6836486314 2016-12-01T17:43:23.51819 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:43:23.51821 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:43:23.57687 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:43:23.57690 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:43:23.57690 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:43:23.57690 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:43:23.57691 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:43:23.57691 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:43:23.57692 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:43:23.57692 0.03121747] 2016-12-01T17:43:23.57693 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:43:23.57693 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:43:23.57694 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:43:23.57694 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:43:23.58036 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:43:23.58390 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:43:23.58420 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:43:30.58436 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:43:30.62289 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6784747437 2016-12-01T17:43:30.62368 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6784747437 2016-12-01T17:43:30.68566 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:43:30.68568 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:43:30.70760 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:43:30.70766 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:43:30.70773 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:43:30.70779 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:43:30.70840 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:43:30.70841 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:43:30.70841 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:43:30.70842 0.03121747] 2016-12-01T17:43:30.70848 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:43:30.70853 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:43:30.70860 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:43:30.70866 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:43:30.71062 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:43:30.71122 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:43:30.71147 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:43:37.71168 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:43:37.73473 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6805758319 2016-12-01T17:43:37.73576 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6805758319 2016-12-01T17:43:37.79791 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:43:37.79793 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:43:38.44027 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:43:38.44034 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:43:38.44041 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:43:38.44047 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:43:38.44186 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:43:38.44187 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:43:38.44188 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:43:38.44189 0.03121747] 2016-12-01T17:43:38.44189 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:43:38.44190 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:43:38.44190 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:43:38.44191 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:43:38.44735 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:43:38.44786 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:43:38.44891 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:43:45.44866 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:43:45.46036 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6844742243 2016-12-01T17:43:45.46099 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6844742243 2016-12-01T17:43:45.52424 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:43:45.52426 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:43:45.55227 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:43:45.55382 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:43:45.55383 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:43:45.55384 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:43:45.55384 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:43:45.55385 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:43:45.55385 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:43:45.55386 0.03121747] 2016-12-01T17:43:45.55386 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:43:45.55386 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:43:45.55387 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:43:45.55387 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:43:45.56636 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:43:45.56786 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:43:45.56806 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:43:52.56899 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:43:52.61481 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6786833176 2016-12-01T17:43:52.61953 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6786833176 2016-12-01T17:43:52.67877 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:43:52.67896 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:43:52.75195 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:43:52.75206 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:43:52.75211 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:43:52.75219 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:43:52.75347 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:43:52.75348 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:43:52.75349 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:43:52.75349 0.03121747] 2016-12-01T17:43:52.75350 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:43:52.75351 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:43:52.75351 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:43:52.75352 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:43:52.76032 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:43:52.76096 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:43:52.76126 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:43:59.76347 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:43:59.77824 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6832310413 2016-12-01T17:43:59.78379 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6832310413 2016-12-01T17:43:59.84485 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:43:59.84488 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:43:59.86939 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:43:59.86941 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:43:59.86941 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:43:59.86942 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:43:59.86942 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:43:59.86943 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:43:59.86943 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:43:59.86944 0.03121747] 2016-12-01T17:43:59.86944 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:43:59.86945 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:43:59.86945 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:43:59.86946 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:43:59.87018 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:43:59.87089 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:43:59.87120 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:44:06.87159 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:44:06.90006 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6853972376 2016-12-01T17:44:06.90037 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6853972376 2016-12-01T17:44:06.95626 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:44:06.95628 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:44:07.01171 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:44:07.01173 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:44:07.01173 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:44:07.01173 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:44:07.01174 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:44:07.01175 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:44:07.01175 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:44:07.01176 0.03121747] 2016-12-01T17:44:07.01176 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:44:07.01176 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:44:07.01176 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:44:07.01177 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:44:07.01847 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:44:07.01908 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:44:07.01950 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:44:14.02144 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:44:14.05281 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6861333677 2016-12-01T17:44:14.05569 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6861333677 2016-12-01T17:44:14.11213 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:44:14.11224 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:44:14.16655 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:44:14.16657 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:44:14.16658 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:44:14.16658 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:44:14.16680 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:44:14.16681 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:44:14.16681 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:44:14.16682 0.03121747] 2016-12-01T17:44:14.16722 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:44:14.16723 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:44:14.16724 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:44:14.16724 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:44:14.17003 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:44:14.17323 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:44:14.17445 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:44:21.17490 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:44:21.22624 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6874248264 2016-12-01T17:44:21.23050 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6874248264 2016-12-01T17:44:21.28920 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:44:21.28923 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:44:21.32574 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:44:21.32580 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:44:21.32588 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:44:21.32595 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:44:21.32657 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:44:21.32658 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:44:21.32659 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:44:21.32660 0.03121747] 2016-12-01T17:44:21.32666 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:44:21.32671 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:44:21.32678 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:44:21.32685 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:44:21.33137 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:44:21.33202 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:44:21.33233 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:44:28.33255 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:44:28.39444 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6864045665 2016-12-01T17:44:28.39693 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6864045665 2016-12-01T17:44:28.45728 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:44:28.45730 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:44:28.49081 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:44:28.49083 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:44:28.49083 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:44:28.49084 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:44:28.49146 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:44:28.49148 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:44:28.49149 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:44:28.49149 0.03121747] 2016-12-01T17:44:28.49150 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:44:28.49150 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:44:28.49150 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:44:28.49151 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:44:28.50507 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:44:28.51001 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:44:28.51030 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:44:35.51086 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:44:35.56027 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6889412365 2016-12-01T17:44:35.56241 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6889412365 2016-12-01T17:44:35.62559 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:44:35.62561 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:44:35.65511 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:44:35.65513 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:44:35.65514 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:44:35.65514 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:44:35.65515 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:44:35.65515 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:44:35.65516 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:44:35.65516 0.03121747] 2016-12-01T17:44:35.65517 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:44:35.65517 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:44:35.65518 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:44:35.65518 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:44:35.66381 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:44:35.67092 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:44:35.67117 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:44:42.67139 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:44:42.67423 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6837386857 2016-12-01T17:44:42.67978 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6837386857 2016-12-01T17:44:42.73678 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:44:42.73680 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:44:42.82324 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:44:42.82326 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:44:42.82327 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:44:42.82327 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:44:42.82327 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:44:42.82328 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:44:42.82328 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:44:42.82328 0.03121747] 2016-12-01T17:44:42.82329 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:44:42.82329 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:44:42.82329 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:44:42.82330 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:44:42.82409 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:44:42.82478 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:44:42.82503 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:44:49.82556 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:44:49.84056 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6936439544 2016-12-01T17:44:49.84134 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6936439544 2016-12-01T17:44:49.90597 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:44:49.90599 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:44:49.92913 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:44:49.92915 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:44:49.92915 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:44:49.92916 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:44:49.92968 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:44:49.92969 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:44:49.92970 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:44:49.92970 0.03121747] 2016-12-01T17:44:49.92971 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:44:49.92971 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:44:49.92972 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:44:49.92972 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:44:49.93948 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:44:49.94216 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:44:49.94273 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:44:56.94266 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:44:56.94880 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6898787814 2016-12-01T17:44:56.94934 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6898787814 2016-12-01T17:44:57.01323 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:44:57.01326 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:44:57.04711 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:44:57.04718 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:44:57.04729 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:44:57.04735 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:44:57.04791 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:44:57.04792 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:44:57.04793 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:44:57.04793 0.03121747] 2016-12-01T17:44:57.04800 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:44:57.04805 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:44:57.04812 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:44:57.04818 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:44:57.05276 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:44:57.05462 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:44:57.05509 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:45:04.05544 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:45:04.06708 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6873945116 2016-12-01T17:45:04.06898 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6873945116 2016-12-01T17:45:04.13237 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:45:04.13238 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:45:04.16061 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:45:04.16063 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:45:04.16063 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:45:04.16064 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:45:04.16064 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:45:04.16065 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:45:04.16065 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:45:04.16066 0.03121747] 2016-12-01T17:45:04.16066 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:45:04.16067 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:45:04.16067 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:45:04.16068 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:45:04.16562 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:45:04.16807 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:45:04.16840 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:45:11.16892 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:45:11.19890 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6869458196 2016-12-01T17:45:11.20685 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6869458196 2016-12-01T17:45:11.25726 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:45:11.25728 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:45:11.30121 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:45:11.30124 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:45:11.30124 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:45:11.30125 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:45:11.30125 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:45:11.30126 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:45:11.30126 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:45:11.30127 0.03121747] 2016-12-01T17:45:11.30127 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:45:11.30128 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:45:11.30128 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:45:11.30128 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:45:11.31135 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:45:11.31825 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:45:11.31858 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:45:18.31901 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:45:18.35859 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6902122847 2016-12-01T17:45:18.35959 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6902122847 2016-12-01T17:45:18.42182 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:45:18.42184 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:45:18.46237 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:45:18.46240 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:45:18.46240 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:45:18.46241 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:45:18.46376 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:45:18.46377 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:45:18.46377 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:45:18.46378 0.03121747] 2016-12-01T17:45:18.46378 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:45:18.46379 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:45:18.46379 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:45:18.46379 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:45:18.47167 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:45:18.47303 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:45:18.47334 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:45:25.47366 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:45:25.53180 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6884060918 2016-12-01T17:45:25.53778 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6884060918 2016-12-01T17:45:25.59347 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:45:25.59350 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:45:25.62031 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:45:25.62033 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:45:25.62034 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:45:25.62034 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:45:25.62035 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:45:25.62035 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:45:25.62036 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:45:25.62036 0.03121747] 2016-12-01T17:45:25.62037 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:45:25.62037 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:45:25.62038 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:45:25.62038 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:45:25.62710 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:45:25.63621 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:45:25.63654 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:45:32.63726 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:45:32.69393 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6910535945 2016-12-01T17:45:32.69721 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6910535945 2016-12-01T17:45:32.75786 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:45:32.75822 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:45:33.04572 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:45:33.04733 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:45:33.04734 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:45:33.04735 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:45:33.04735 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:45:33.04736 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:45:33.04736 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:45:33.04737 0.03121747] 2016-12-01T17:45:33.04737 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:45:33.04738 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:45:33.04738 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:45:33.04739 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:45:33.05370 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:45:33.05743 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:45:33.05802 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:45:40.05822 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:45:40.12653 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6894917743 2016-12-01T17:45:40.13214 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6894917743 2016-12-01T17:45:40.18235 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:45:40.18252 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:45:40.20785 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:45:40.20789 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:45:40.20795 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:45:40.20799 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:45:40.20853 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:45:40.20854 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:45:40.20855 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:45:40.20855 0.03121747] 2016-12-01T17:45:40.20862 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:45:40.20898 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:45:40.20900 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:45:40.20900 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:45:40.20995 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:45:40.21054 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:45:40.21082 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:45:47.21121 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:45:47.22673 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6871155043 2016-12-01T17:45:47.23011 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6871155043 2016-12-01T17:45:47.29045 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:45:47.29047 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:45:47.32111 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:45:47.32124 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:45:47.32234 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:45:47.32235 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:45:47.32299 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:45:47.32300 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:45:47.32301 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:45:47.32301 0.03121747] 2016-12-01T17:45:47.32302 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:45:47.32302 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:45:47.32303 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:45:47.32303 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:45:47.33216 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:45:47.33294 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:45:47.33330 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:45:54.33344 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:45:54.39273 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6889587897 2016-12-01T17:45:54.39339 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6889587897 2016-12-01T17:45:54.45558 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:45:54.45560 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:45:54.48607 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:45:54.48610 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:45:54.48610 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:45:54.48611 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:45:54.48611 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:45:54.48612 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:45:54.48612 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:45:54.48614 0.03121747] 2016-12-01T17:45:54.48615 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:45:54.48615 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:45:54.48616 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:45:54.48616 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:45:54.49395 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:45:54.49456 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:45:54.49877 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:46:01.49923 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:46:01.56140 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6925796312 2016-12-01T17:46:01.56472 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6925796312 2016-12-01T17:46:01.62572 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:46:01.62574 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:46:01.66529 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:46:01.66531 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:46:01.66678 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:46:01.66679 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:46:01.66680 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:46:01.66680 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:46:01.66681 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:46:01.66681 0.03121747] 2016-12-01T17:46:01.66682 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:46:01.66683 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:46:01.66683 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:46:01.66684 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:46:01.66949 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:46:01.67013 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:46:01.67045 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:46:08.67185 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:46:08.72514 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6930797374 2016-12-01T17:46:08.72760 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6930797374 2016-12-01T17:46:08.78842 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:46:08.78844 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:46:08.82831 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:46:08.82833 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:46:08.82834 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:46:08.82834 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:46:08.82835 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:46:08.82837 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:46:08.82838 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:46:08.82838 0.03121747] 2016-12-01T17:46:08.82838 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:46:08.82839 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:46:08.82839 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:46:08.82840 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:46:08.83085 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:46:08.83145 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:46:08.83167 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:46:15.83333 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:46:15.83507 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.68758229 2016-12-01T17:46:15.83810 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.68758229 2016-12-01T17:46:15.89886 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:46:15.89920 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:46:15.93568 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:46:15.93570 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:46:15.93571 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:46:15.93571 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:46:15.93572 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:46:15.93572 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:46:15.93573 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:46:15.93573 0.03121747] 2016-12-01T17:46:15.93574 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:46:15.93574 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:46:15.93575 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:46:15.93575 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:46:15.93943 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:46:15.94017 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:46:15.94051 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:46:22.94081 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:46:22.94473 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6905804207 2016-12-01T17:46:22.94750 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6905804207 2016-12-01T17:46:23.00691 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:46:23.00693 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:46:23.03100 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:46:23.03102 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:46:23.03103 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:46:23.03104 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:46:23.03104 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:46:23.03105 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:46:23.03105 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:46:23.03106 0.03121747] 2016-12-01T17:46:23.03106 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:46:23.03107 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:46:23.03107 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:46:23.03107 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:46:23.04143 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:46:23.04641 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:46:23.04998 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:46:30.04965 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:46:30.10864 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.689445574 2016-12-01T17:46:30.10934 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.689445574 2016-12-01T17:46:30.17229 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:46:30.17231 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:46:30.20244 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:46:30.20247 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:46:30.20247 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:46:30.20248 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:46:30.20249 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:46:30.20249 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:46:30.20250 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:46:30.20250 0.03121747] 2016-12-01T17:46:30.20257 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:46:30.20292 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:46:30.20293 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:46:30.20293 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:46:30.20945 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:46:30.21016 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:46:30.21039 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:46:37.21059 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:46:37.21155 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6917005043 2016-12-01T17:46:37.21394 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6917005043 2016-12-01T17:46:37.28063 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:46:37.28066 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:46:37.31358 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:46:37.31365 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:46:37.31375 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:46:37.31525 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:46:37.31526 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:46:37.31526 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:46:37.31527 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:46:37.31527 0.03121747] 2016-12-01T17:46:37.31528 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:46:37.31528 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:46:37.31529 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:46:37.31529 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:46:37.31712 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:46:37.31977 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:46:37.32009 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:46:44.32023 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:46:44.38261 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6889305701 2016-12-01T17:46:44.38329 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6889305701 2016-12-01T17:46:44.44575 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:46:44.44604 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:46:44.47846 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:46:44.47853 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:46:44.47861 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:46:44.47869 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:46:44.47958 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:46:44.47960 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:46:44.47960 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:46:44.47961 0.03121747] 2016-12-01T17:46:44.47972 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:46:44.47981 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:46:44.47991 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:46:44.48001 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:46:44.48990 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:46:44.49525 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:46:44.49574 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:46:51.49832 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:46:51.55344 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6928296079 2016-12-01T17:46:51.55444 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6928296079 2016-12-01T17:46:51.61580 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:46:51.61584 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:46:51.64676 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:46:51.64912 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:46:51.64913 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:46:51.64914 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:46:51.64914 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:46:51.64915 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:46:51.64915 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:46:51.64916 0.03121747] 2016-12-01T17:46:51.64916 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:46:51.64917 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:46:51.64917 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:46:51.64918 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:46:51.65171 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:46:51.65288 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:46:51.65618 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:46:58.65923 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:46:58.66105 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6895884149 2016-12-01T17:46:58.66236 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6895884149 2016-12-01T17:46:58.72514 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:46:58.72516 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:46:58.75388 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:46:58.75390 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:46:58.75391 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:46:58.75392 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:46:58.75392 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:46:58.75393 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:46:58.75393 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:46:58.75394 0.03121747] 2016-12-01T17:46:58.75394 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:46:58.75395 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:46:58.75395 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:46:58.75420 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:46:58.76303 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:46:58.77015 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:46:58.77121 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:47:05.77412 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:47:05.83299 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6891086705 2016-12-01T17:47:05.83938 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6891086705 2016-12-01T17:47:05.89669 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:47:05.89671 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:47:05.92187 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:47:05.92200 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:47:05.92211 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:47:05.92222 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:47:05.92321 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:47:05.92322 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:47:05.92322 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:47:05.92323 0.03121747] 2016-12-01T17:47:05.92334 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:47:05.92340 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:47:05.92347 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:47:05.92353 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:47:05.93411 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:47:05.93837 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:47:05.93870 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:47:12.93882 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:47:13.00312 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6876343492 2016-12-01T17:47:13.00979 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6876343492 2016-12-01T17:47:13.06286 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:47:13.06923 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:47:13.09402 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:47:13.09404 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:47:13.09405 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:47:13.09406 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:47:13.09406 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:47:13.09407 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:47:13.09407 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:47:13.09408 0.03121747] 2016-12-01T17:47:13.09408 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:47:13.09409 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:47:13.09409 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:47:13.09410 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:47:13.09988 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:47:13.10613 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:47:13.10657 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:47:20.10662 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:47:20.10738 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6962493545 2016-12-01T17:47:20.10924 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6962493545 2016-12-01T17:47:20.17164 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:47:20.17167 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:47:20.22771 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:47:20.22773 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:47:20.22774 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:47:20.22774 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:47:20.22775 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:47:20.22775 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:47:20.22776 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:47:20.22776 0.03121747] 2016-12-01T17:47:20.22777 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:47:20.22777 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:47:20.22777 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:47:20.22778 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:47:20.23422 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:47:20.23548 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:47:20.23667 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:47:27.23701 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:47:27.28322 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6869583548 2016-12-01T17:47:27.28660 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6869583548 2016-12-01T17:47:27.34418 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:47:27.34420 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:47:27.37548 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:47:27.37550 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:47:27.37550 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:47:27.37551 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:47:27.37551 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:47:27.37552 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:47:27.37552 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:47:27.37553 0.03121747] 2016-12-01T17:47:27.37553 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:47:27.37554 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:47:27.37554 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:47:27.37555 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:47:27.37788 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:47:27.38740 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:47:27.38868 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:47:34.39148 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:47:34.45219 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6879951156 2016-12-01T17:47:34.45633 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6879951156 2016-12-01T17:47:34.51811 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:47:34.51813 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:47:34.54817 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:47:34.54819 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:47:34.54820 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:47:34.54820 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:47:34.54821 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:47:34.54821 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:47:34.54822 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:47:34.54822 0.03121747] 2016-12-01T17:47:34.54823 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:47:34.54823 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:47:34.54824 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:47:34.54824 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:47:34.54946 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:47:34.55013 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:47:34.55026 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:47:41.55177 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:47:41.56194 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6905510841 2016-12-01T17:47:41.56251 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6905510841 2016-12-01T17:47:41.62322 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:47:41.62339 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:47:41.65690 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:47:41.65692 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:47:41.65692 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:47:41.65693 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:47:41.65693 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:47:41.65693 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:47:41.65694 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:47:41.65694 0.03121747] 2016-12-01T17:47:41.65694 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:47:41.65696 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:47:41.65696 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:47:41.65696 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:47:41.66826 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:47:41.67430 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:47:41.67479 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:47:48.67608 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:47:48.73523 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.692342647 2016-12-01T17:47:48.73631 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.692342647 2016-12-01T17:47:48.79856 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:47:48.79868 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:47:48.83562 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:47:48.83564 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:47:48.83565 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:47:48.83565 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:47:48.83628 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:47:48.83629 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:47:48.83630 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:47:48.83630 0.03121747] 2016-12-01T17:47:48.83636 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:47:48.83643 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:47:48.83650 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:47:48.83656 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:47:48.83756 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:47:48.84427 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:47:48.84569 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:47:55.84471 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:47:55.85361 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6954455842 2016-12-01T17:47:55.85539 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6954455842 2016-12-01T17:47:55.91646 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:47:55.91663 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:47:55.95432 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:47:55.95435 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:47:55.95442 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:47:55.95535 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:47:55.95588 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:47:55.95589 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:47:55.95591 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:47:55.95592 0.03121747] 2016-12-01T17:47:55.95592 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:47:55.95593 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:47:55.95593 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:47:55.95594 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:47:55.96354 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:47:55.96410 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:47:55.96432 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:48:02.96746 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:48:03.02651 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6953680986 2016-12-01T17:48:03.03250 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6953680986 2016-12-01T17:48:03.09078 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:48:03.09094 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:48:03.12273 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:48:03.12275 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:48:03.12276 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:48:03.12276 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:48:03.12277 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:48:03.12277 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:48:03.12278 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:48:03.12278 0.03121747] 2016-12-01T17:48:03.12279 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:48:03.12279 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:48:03.12280 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:48:03.12280 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:48:03.12782 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:48:03.12920 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:48:03.13179 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:48:10.13319 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:48:10.19068 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6943208541 2016-12-01T17:48:10.19115 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6943208541 2016-12-01T17:48:10.25517 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:48:10.25520 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:48:10.28549 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:48:10.28629 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:48:10.28630 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:48:10.28632 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:48:10.28657 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:48:10.28657 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:48:10.28658 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:48:10.28659 0.03121747] 2016-12-01T17:48:10.28669 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:48:10.28678 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:48:10.28687 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:48:10.28696 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:48:10.28815 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:48:10.28876 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:48:10.28905 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:48:17.28951 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:48:17.30673 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6928078115 2016-12-01T17:48:17.31188 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6928078115 2016-12-01T17:48:17.37431 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:48:17.37434 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:48:17.40512 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:48:17.40514 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:48:17.40515 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:48:17.40515 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:48:17.40516 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:48:17.40516 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:48:17.40517 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:48:17.40517 0.03121747] 2016-12-01T17:48:17.40518 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:48:17.40518 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:48:17.40519 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:48:17.40519 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:48:17.40972 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:48:17.41038 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:48:17.41071 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:48:24.41140 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:48:24.42883 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6928649435 2016-12-01T17:48:24.43200 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6928649435 2016-12-01T17:48:24.49064 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:48:24.49075 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:48:24.51712 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:48:24.51723 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:48:24.51735 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:48:24.51746 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:48:24.51842 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:48:24.51843 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:48:24.51844 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:48:24.51844 0.03121747] 2016-12-01T17:48:24.51856 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:48:24.51866 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:48:24.51877 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:48:24.51888 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:48:24.52577 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:48:24.52756 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:48:24.52804 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:48:31.53133 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:48:31.53576 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6995187232 2016-12-01T17:48:31.53764 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6995187232 2016-12-01T17:48:31.59789 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:48:31.59792 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:48:31.62932 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:48:31.62935 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:48:31.63187 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:48:31.63188 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:48:31.63189 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:48:31.63189 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:48:31.63190 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:48:31.63190 0.03121747] 2016-12-01T17:48:31.63191 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:48:31.63191 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:48:31.63192 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:48:31.63192 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:48:31.63980 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:48:31.64112 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:48:31.64151 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:48:38.64288 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:48:38.70296 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6946666223 2016-12-01T17:48:38.70445 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6946666223 2016-12-01T17:48:38.77108 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:48:38.77110 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:48:38.80705 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:48:38.80707 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:48:38.80708 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:48:38.80834 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:48:38.80835 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:48:38.80836 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:48:38.80837 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:48:38.80837 0.03121747] 2016-12-01T17:48:38.80838 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:48:38.80838 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:48:38.80839 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:48:38.80839 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:48:38.81883 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:48:38.82363 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:48:38.82390 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:48:45.82422 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:48:45.86619 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6926543018 2016-12-01T17:48:45.86884 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6926543018 2016-12-01T17:48:45.92804 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:48:45.92817 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:48:45.97590 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:48:45.97596 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:48:45.97605 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:48:45.97745 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:48:45.97746 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:48:45.97746 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:48:45.97747 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:48:45.97747 0.03121747] 2016-12-01T17:48:45.97747 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:48:45.97748 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:48:45.97748 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:48:45.97749 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:48:45.98449 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:48:45.98872 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:48:45.98899 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:48:52.98977 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:48:53.02698 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6948691846 2016-12-01T17:48:53.02751 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6948691846 2016-12-01T17:48:53.08974 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:48:53.08998 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:48:53.11860 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:48:53.11876 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:48:53.11877 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:48:53.11884 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:48:53.11938 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:48:53.11939 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:48:53.11940 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:48:53.11940 0.03121747] 2016-12-01T17:48:53.11979 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:48:53.11980 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:48:53.11981 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:48:53.11981 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:48:53.12081 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:48:53.12483 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:48:53.12524 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:49:00.12564 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:49:00.13582 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6893689561 2016-12-01T17:49:00.14038 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6893689561 2016-12-01T17:49:00.19870 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:49:00.19872 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:49:00.22426 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:49:00.22428 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:49:00.22429 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:49:00.22429 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:49:00.22566 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:49:00.22567 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:49:00.22568 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:49:00.22569 0.03121747] 2016-12-01T17:49:00.22569 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:49:00.22570 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:49:00.22570 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:49:00.22571 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:49:00.23385 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:49:00.23982 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:49:00.24015 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:49:07.24085 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:49:07.25485 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6916289636 2016-12-01T17:49:07.25576 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6916289636 2016-12-01T17:49:07.31759 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:49:07.31764 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:49:07.39762 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:49:07.39764 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:49:07.39765 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:49:07.39765 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:49:07.39814 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:49:07.39815 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:49:07.39816 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:49:07.39816 0.03121747] 2016-12-01T17:49:07.39821 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:49:07.39826 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:49:07.39832 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:49:07.39839 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:49:07.39964 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:49:07.40016 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:49:07.40037 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:49:14.40093 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:49:14.43274 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6996186228 2016-12-01T17:49:14.43362 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6996186228 2016-12-01T17:49:14.49509 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:49:14.49526 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:49:14.52609 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:49:14.52746 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:49:14.52747 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:49:14.52747 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:49:14.52748 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:49:14.52748 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:49:14.52749 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:49:14.52749 0.03121747] 2016-12-01T17:49:14.52750 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:49:14.52750 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:49:14.52750 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:49:14.52761 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:49:14.53041 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:49:14.53359 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:49:14.53381 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:49:21.53517 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:49:21.53587 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6980185625 2016-12-01T17:49:21.54088 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6980185625 2016-12-01T17:49:21.59714 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:49:21.59730 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:49:21.64139 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:49:21.64140 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:49:21.64141 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:49:21.64141 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:49:21.64142 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:49:21.64142 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:49:21.64143 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:49:21.64143 0.03121747] 2016-12-01T17:49:21.64144 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:49:21.64144 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:49:21.64144 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:49:21.64145 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:49:21.65151 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:49:21.65893 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:49:21.66165 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:49:28.66244 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:49:28.70392 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6952111075 2016-12-01T17:49:28.70546 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6952111075 2016-12-01T17:49:28.76780 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:49:28.76793 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:49:28.80640 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:49:28.80651 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:49:28.80663 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:49:28.80674 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:49:28.80911 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:49:28.80912 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:49:28.80912 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:49:28.80913 0.03121747] 2016-12-01T17:49:28.80924 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:49:28.80933 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:49:28.80945 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:49:28.80951 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:49:28.81445 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:49:28.82369 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:49:28.82576 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:49:35.82617 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:49:35.86828 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6912914199 2016-12-01T17:49:35.86894 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6912914199 2016-12-01T17:49:35.93148 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:49:35.93180 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:49:35.98360 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:49:35.98362 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:49:35.98363 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:49:35.98363 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:49:35.98364 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:49:35.98364 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:49:35.98365 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:49:35.98366 0.03121747] 2016-12-01T17:49:35.98366 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:49:35.98367 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:49:35.98367 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:49:35.98368 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:49:36.01154 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:49:36.01675 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:49:36.01759 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:49:43.01794 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:49:43.03780 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6900184156 2016-12-01T17:49:43.04052 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6900184156 2016-12-01T17:49:43.09937 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:49:43.09939 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:49:43.18032 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:49:43.18035 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:49:43.18035 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:49:43.18036 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:49:43.18036 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:49:43.18037 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:49:43.18038 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:49:43.18040 0.03121747] 2016-12-01T17:49:43.18040 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:49:43.18041 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:49:43.18041 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:49:43.18042 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:49:43.18659 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:49:43.18789 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:49:43.18830 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:49:50.18846 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:49:50.19620 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6985237519 2016-12-01T17:49:50.19661 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6985237519 2016-12-01T17:49:50.25869 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:49:50.25880 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:49:50.28403 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:49:50.28405 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:49:50.28409 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:49:50.28416 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:49:50.28466 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:49:50.28467 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:49:50.28468 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:49:50.28468 0.03121747] 2016-12-01T17:49:50.28475 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:49:50.28482 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:49:50.28489 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:49:50.28495 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:49:50.29004 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:49:50.29194 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:49:50.29448 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:49:57.29460 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:49:57.30064 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6961403836 2016-12-01T17:49:57.30110 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6961403836 2016-12-01T17:49:57.36328 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:49:57.36339 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:49:57.39009 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:49:57.39011 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:49:57.39011 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:49:57.39012 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:49:57.39068 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:49:57.39070 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:49:57.39071 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:49:57.39071 0.03121747] 2016-12-01T17:49:57.39099 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:49:57.39100 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:49:57.39100 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:49:57.39101 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:49:57.39217 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:49:57.39268 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:49:57.39296 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:50:04.39614 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:50:04.41967 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6979695891 2016-12-01T17:50:04.42080 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6979695891 2016-12-01T17:50:04.48238 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:50:04.48240 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:50:04.51228 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:50:04.51230 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:50:04.51230 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:50:04.51231 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:50:04.51231 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:50:04.51232 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:50:04.51232 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:50:04.51233 0.03121747] 2016-12-01T17:50:04.51233 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:50:04.51234 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:50:04.51235 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:50:04.51235 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:50:04.51717 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:50:04.52412 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:50:04.52483 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:50:11.52923 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:50:11.56684 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6970917847 2016-12-01T17:50:11.57561 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6970917847 2016-12-01T17:50:11.63004 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:50:11.63006 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:50:11.66482 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:50:11.66484 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:50:11.66486 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:50:11.66487 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:50:11.66487 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:50:11.66488 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:50:11.66488 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:50:11.66489 0.03121747] 2016-12-01T17:50:11.66489 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:50:11.66489 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:50:11.66490 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:50:11.66490 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:50:11.67838 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:50:11.68740 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:50:11.68791 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:50:18.68825 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:50:18.69201 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6980110385 2016-12-01T17:50:18.69253 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6980110385 2016-12-01T17:50:18.75625 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:50:18.75627 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:50:18.81127 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:50:18.81129 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:50:18.81130 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:50:18.81130 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:50:18.81191 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:50:18.81192 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:50:18.81192 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:50:18.81193 0.03121747] 2016-12-01T17:50:18.81193 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:50:18.81193 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:50:18.81194 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:50:18.81194 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:50:18.81432 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:50:18.81491 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:50:18.81515 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:50:25.81557 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:50:25.86106 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6970298216 2016-12-01T17:50:25.86179 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6970298216 2016-12-01T17:50:25.92393 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:50:25.92396 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:50:25.95079 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:50:25.95082 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:50:25.95082 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:50:25.95083 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:50:25.95083 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:50:25.95084 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:50:25.95084 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:50:25.95085 0.03121747] 2016-12-01T17:50:25.95085 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:50:25.95086 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:50:25.95086 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:50:25.95087 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:50:25.95859 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:50:25.95913 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:50:25.95939 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:50:32.95960 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:50:32.96580 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6937032582 2016-12-01T17:50:32.96655 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6937032582 2016-12-01T17:50:33.03199 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:50:33.03201 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:50:33.07488 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:50:33.07651 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:50:33.07652 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:50:33.07652 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:50:33.07653 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:50:33.07653 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:50:33.07654 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:50:33.07654 0.03121747] 2016-12-01T17:50:33.07655 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:50:33.07655 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:50:33.07656 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:50:33.07656 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:50:33.07839 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:50:33.08192 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:50:33.08213 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:50:40.08224 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:50:40.13240 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6945861323 2016-12-01T17:50:40.13577 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6945861323 2016-12-01T17:50:40.19524 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:50:40.19546 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:50:40.22684 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:50:40.22686 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:50:40.22687 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:50:40.22687 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:50:40.22688 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:50:40.22688 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:50:40.22689 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:50:40.22689 0.03121747] 2016-12-01T17:50:40.22690 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:50:40.22690 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:50:40.22690 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:50:40.22691 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:50:40.22873 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:50:40.23059 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:50:40.23232 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:50:47.23359 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:50:47.24352 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.700977913 2016-12-01T17:50:47.24435 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.700977913 2016-12-01T17:50:47.31080 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:50:47.31082 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:50:47.33818 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:50:47.33829 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:50:47.33840 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:50:47.33850 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:50:47.33940 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:50:47.33942 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:50:47.33942 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:50:47.33943 0.03121747] 2016-12-01T17:50:47.33953 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:50:47.33965 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:50:47.33975 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:50:47.33985 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:50:47.34425 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:50:47.34487 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:50:47.34569 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:50:54.34610 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:50:54.35446 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.7068060435 2016-12-01T17:50:54.35518 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.7068060435 2016-12-01T17:50:54.41617 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:50:54.41633 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:50:54.44847 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:50:54.44849 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:50:54.44850 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:50:54.44850 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:50:54.44851 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:50:54.44851 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:50:54.44852 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:50:54.44852 0.03121747] 2016-12-01T17:50:54.44853 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:50:54.44853 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:50:54.44854 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:50:54.44854 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:50:54.45938 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:50:54.46045 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:50:54.46076 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:51:01.46145 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:51:01.47810 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6932601327 2016-12-01T17:51:01.48794 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6932601327 2016-12-01T17:51:01.54313 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:51:01.54316 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:51:01.58025 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:51:01.58027 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:51:01.58028 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:51:01.58028 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:51:01.58057 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:51:01.58058 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:51:01.58059 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:51:01.58059 0.03121747] 2016-12-01T17:51:01.58063 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:51:01.58068 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:51:01.58073 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:51:01.58077 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:51:01.58657 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:51:01.58718 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:51:01.58974 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:51:08.59010 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:51:08.64473 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.7009195074 2016-12-01T17:51:08.64540 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.7009195074 2016-12-01T17:51:08.70699 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:51:08.70721 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:51:08.74378 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:51:08.74384 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:51:08.74396 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:51:08.74407 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:51:08.74501 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:51:08.74502 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:51:08.74503 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:51:08.74503 0.03121747] 2016-12-01T17:51:08.74515 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:51:08.74525 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:51:08.74536 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:51:08.74546 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:51:08.75293 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:51:08.76290 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:51:08.76316 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:51:15.76978 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:51:15.80159 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6933832017 2016-12-01T17:51:15.80278 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6933832017 2016-12-01T17:51:15.86423 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:51:15.86442 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:51:15.91784 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:51:15.91795 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:51:15.91806 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:51:15.91816 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:51:15.91928 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:51:15.91929 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:51:15.91929 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:51:15.91930 0.03121747] 2016-12-01T17:51:15.91947 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:51:15.91958 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:51:15.91972 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:51:15.91984 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:51:15.92129 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:51:15.92190 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:51:15.92356 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:51:22.92483 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:51:22.96494 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.693345791 2016-12-01T17:51:22.96556 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.693345791 2016-12-01T17:51:23.03189 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:51:23.03192 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:51:23.06226 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:51:23.06233 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:51:23.06240 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:51:23.06247 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:51:23.06301 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:51:23.06302 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:51:23.06303 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:51:23.06303 0.03121747] 2016-12-01T17:51:23.06309 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:51:23.06315 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:51:23.06340 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:51:23.06341 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:51:23.06832 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:51:23.06892 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:51:23.06924 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:51:30.07017 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:51:30.07397 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6928256059 2016-12-01T17:51:30.07450 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6928256059 2016-12-01T17:51:30.13504 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:51:30.13590 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:51:30.17219 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:51:30.17222 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:51:30.17387 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:51:30.17388 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:51:30.17389 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:51:30.17389 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:51:30.17390 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:51:30.17390 0.03121747] 2016-12-01T17:51:30.17391 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:51:30.17393 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:51:30.17393 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:51:30.17394 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:51:30.17606 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:51:30.17672 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:51:30.17704 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:51:37.17819 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:51:37.24031 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.695197724 2016-12-01T17:51:37.24446 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.695197724 2016-12-01T17:51:37.30801 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:51:37.30804 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:51:37.35255 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:51:37.35257 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:51:37.35257 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:51:37.35258 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:51:37.35258 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:51:37.35259 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:51:37.35259 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:51:37.35260 0.03121747] 2016-12-01T17:51:37.35260 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:51:37.35260 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:51:37.35261 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:51:37.35261 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:51:37.35363 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:51:37.35428 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:51:37.35489 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:51:44.35586 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:51:44.41958 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.696819838 2016-12-01T17:51:44.41997 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.696819838 2016-12-01T17:51:44.47951 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:51:44.47952 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:51:44.50380 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:51:44.50387 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:51:44.50397 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:51:44.50405 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:51:44.50530 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:51:44.50531 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:51:44.50533 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:51:44.50533 0.03121747] 2016-12-01T17:51:44.50534 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:51:44.50534 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:51:44.50535 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:51:44.50535 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:51:44.51268 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:51:44.51502 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:51:44.51612 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:51:51.51636 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:51:51.52511 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6935185652 2016-12-01T17:51:51.53388 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6935185652 2016-12-01T17:51:51.58814 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:51:51.58816 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:51:51.62244 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:51:51.62247 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:51:51.62364 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:51:51.62365 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:51:51.62370 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:51:51.62371 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:51:51.62372 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:51:51.62372 0.03121747] 2016-12-01T17:51:51.62384 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:51:51.62394 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:51:51.62405 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:51:51.62416 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:51:51.63319 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:51:51.63574 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:51:51.63622 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:51:58.63675 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:51:58.69386 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6945696859 2016-12-01T17:51:58.69440 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6945696859 2016-12-01T17:51:58.75824 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:51:58.75826 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:51:58.79752 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:51:58.79758 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:51:58.79766 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:51:58.79775 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:51:58.79840 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:51:58.79841 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:51:58.79842 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:51:58.79842 0.03121747] 2016-12-01T17:51:58.79851 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:51:58.79856 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:51:58.79863 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:51:58.79869 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:51:58.80587 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:51:58.80686 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:51:58.80692 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:52:05.80760 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:52:05.86792 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6989777527 2016-12-01T17:52:05.86794 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6989777527 2016-12-01T17:52:05.92787 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:52:05.92789 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:52:05.95610 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:52:05.95612 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:52:05.95613 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:52:05.95613 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:52:05.95745 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:52:05.95746 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:52:05.95747 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:52:05.95747 0.03121747] 2016-12-01T17:52:05.95748 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:52:05.95748 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:52:05.95748 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:52:05.95749 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:52:05.95862 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:52:05.96636 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:52:05.96700 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:52:12.96685 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:52:13.03734 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6985446876 2016-12-01T17:52:13.03852 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6985446876 2016-12-01T17:52:13.09049 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:52:13.09062 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:52:13.11786 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:52:13.11789 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:52:13.11789 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:52:13.11790 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:52:13.11790 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:52:13.11791 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:52:13.11791 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:52:13.11792 0.03121747] 2016-12-01T17:52:13.11792 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:52:13.11793 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:52:13.11793 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:52:13.11794 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:52:13.12145 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:52:13.12421 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:52:13.12773 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:52:20.13010 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:52:20.14022 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6947137336 2016-12-01T17:52:20.14144 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6947137336 2016-12-01T17:52:20.19316 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:52:20.19332 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:52:20.22796 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:52:20.22798 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:52:20.22799 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:52:20.22799 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:52:20.22830 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:52:20.22831 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:52:20.22831 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:52:20.22832 0.03121747] 2016-12-01T17:52:20.22844 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:52:20.22854 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:52:20.22865 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:52:20.22875 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:52:20.23278 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:52:20.23344 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:52:20.23379 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:52:27.23601 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:52:27.29799 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6984019615 2016-12-01T17:52:27.29954 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6984019615 2016-12-01T17:52:27.35556 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:52:27.35579 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:52:27.39989 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:52:27.40002 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:52:27.40014 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:52:27.40025 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:52:27.40121 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:52:27.40122 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:52:27.40123 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:52:27.40123 0.03121747] 2016-12-01T17:52:27.40135 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:52:27.40145 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:52:27.40156 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:52:27.40167 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:52:27.40942 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:52:27.41010 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:52:27.41041 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:52:34.41071 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:52:34.44431 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6955002337 2016-12-01T17:52:34.44477 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6955002337 2016-12-01T17:52:34.50876 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:52:34.50891 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:52:34.54794 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:52:34.54795 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:52:34.54795 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:52:34.54921 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:52:34.54922 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:52:34.54922 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:52:34.54923 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:52:34.54924 0.03121747] 2016-12-01T17:52:34.54924 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:52:34.54925 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:52:34.54925 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:52:34.54926 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:52:34.55170 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:52:34.55232 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:52:34.55262 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:52:41.55291 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:52:41.60924 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.698153502 2016-12-01T17:52:41.61565 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.698153502 2016-12-01T17:52:41.67006 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:52:41.67018 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:52:41.70342 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:52:41.70349 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:52:41.70362 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:52:41.70370 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:52:41.70466 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:52:41.70467 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:52:41.70467 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:52:41.70468 0.03121747] 2016-12-01T17:52:41.70480 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:52:41.70490 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:52:41.70501 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:52:41.70511 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:52:41.70674 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:52:41.70738 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:52:41.70793 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:52:48.71063 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:52:48.77202 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6968066111 2016-12-01T17:52:48.77277 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6968066111 2016-12-01T17:52:48.83486 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:52:48.83524 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:52:48.88946 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:52:48.88948 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:52:48.88948 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:52:48.88948 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:52:48.89047 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:52:48.89048 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:52:48.89048 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:52:48.89049 0.03121747] 2016-12-01T17:52:48.89049 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:52:48.89049 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:52:48.89050 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:52:48.89050 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:52:48.89664 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:52:48.89913 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:52:48.89926 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:52:55.90229 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:52:55.93234 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6964377894 2016-12-01T17:52:55.93305 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6964377894 2016-12-01T17:52:55.99660 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:52:55.99662 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:52:56.02501 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:52:56.02504 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:52:56.02504 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:52:56.02505 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:52:56.02505 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:52:56.02506 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:52:56.02506 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:52:56.02507 0.03121747] 2016-12-01T17:52:56.02507 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:52:56.02507 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:52:56.02508 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:52:56.02508 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:52:56.02729 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:52:56.04057 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:52:56.04101 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:53:03.04119 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:53:03.09962 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6951279512 2016-12-01T17:53:03.10220 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6951279512 2016-12-01T17:53:03.16515 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:53:03.16526 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:53:03.19124 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:53:03.19634 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:53:03.19636 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:53:03.19637 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:53:03.19637 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:53:03.19638 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:53:03.19638 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:53:03.19639 0.03121747] 2016-12-01T17:53:03.19639 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:53:03.19640 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:53:03.19640 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:53:03.19641 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:53:03.19641 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:53:03.19643 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:53:03.19682 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:53:10.19734 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:53:10.20608 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.694600849 2016-12-01T17:53:10.20663 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.694600849 2016-12-01T17:53:10.26879 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:53:10.26892 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:53:10.29416 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:53:10.29418 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:53:10.29419 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:53:10.29420 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:53:10.29500 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:53:10.29501 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:53:10.29502 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:53:10.29503 0.03121747] 2016-12-01T17:53:10.29503 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:53:10.29504 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:53:10.29504 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:53:10.29505 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:53:10.29928 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:53:10.30283 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:53:10.30416 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:53:17.30595 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:53:17.36701 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6984428526 2016-12-01T17:53:17.36795 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6984428526 2016-12-01T17:53:17.42917 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:53:17.42926 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:53:17.45658 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:53:17.45661 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:53:17.45661 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:53:17.45662 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:53:17.45666 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:53:17.45667 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:53:17.45668 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:53:17.45669 0.03121747] 2016-12-01T17:53:17.45680 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:53:17.45689 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:53:17.45701 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:53:17.45711 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:53:17.46006 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:53:17.46178 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:53:17.46257 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:53:24.46529 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:53:24.46701 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6970443531 2016-12-01T17:53:24.46742 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6970443531 2016-12-01T17:53:24.53012 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:53:24.53029 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:53:24.56295 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:53:24.56297 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:53:24.56297 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:53:24.56298 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:53:24.56368 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:53:24.56369 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:53:24.56369 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:53:24.56370 0.03121747] 2016-12-01T17:53:24.56370 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:53:24.56371 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:53:24.56371 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:53:24.56372 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:53:24.56723 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:53:24.56786 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:53:24.56817 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:53:31.56821 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:53:31.57488 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.7011808223 2016-12-01T17:53:31.57686 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.7011808223 2016-12-01T17:53:31.63771 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:53:31.63784 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:53:31.68078 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:53:31.68080 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:53:31.68238 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:53:31.68239 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:53:31.68239 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:53:31.68240 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:53:31.68240 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:53:31.68242 0.03121747] 2016-12-01T17:53:31.68242 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:53:31.68243 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:53:31.68243 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:53:31.68244 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:53:31.68619 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:53:31.69021 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:53:31.69112 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:53:38.69138 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:53:38.75022 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6944437105 2016-12-01T17:53:38.75075 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6944437105 2016-12-01T17:53:38.81011 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:53:38.81013 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:53:38.85252 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:53:38.85255 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:53:38.85255 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:53:38.85256 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:53:38.85256 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:53:38.85257 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:53:38.85257 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:53:38.85258 0.03121747] 2016-12-01T17:53:38.85258 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:53:38.85259 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:53:38.85259 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:53:38.85261 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:53:38.85832 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:53:38.86536 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:53:38.86538 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:53:45.86532 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:53:45.91576 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6920682236 2016-12-01T17:53:45.91659 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6920682236 2016-12-01T17:53:45.97941 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:53:45.97962 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:53:46.02426 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:53:46.02438 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:53:46.02450 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:53:46.02461 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:53:46.02556 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:53:46.02558 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:53:46.02559 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:53:46.02559 0.03121747] 2016-12-01T17:53:46.02570 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:53:46.02580 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:53:46.02590 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:53:46.02600 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:53:46.03156 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:53:46.03474 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:53:46.03535 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:53:53.03638 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:53:53.08261 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6992999598 2016-12-01T17:53:53.08564 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6992999598 2016-12-01T17:53:53.14787 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:53:53.14789 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:53:53.24972 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:53:53.24975 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:53:53.24976 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:53:53.24976 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:53:53.25027 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:53:53.25028 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:53:53.25028 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:53:53.25029 0.03121747] 2016-12-01T17:53:53.25039 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:53:53.25048 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:53:53.25058 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:53:53.25068 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:53:53.26221 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:53:53.26516 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:53:53.26925 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:54:00.26978 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:54:00.32354 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6937359601 2016-12-01T17:54:00.32625 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6937359601 2016-12-01T17:54:00.38778 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:54:00.38781 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:54:00.41845 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:54:00.41857 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:54:00.41870 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:54:00.41881 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:54:00.41981 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:54:00.41982 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:54:00.41983 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:54:00.41983 0.03121747] 2016-12-01T17:54:00.41994 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:54:00.42004 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:54:00.42015 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:54:00.42025 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:54:00.42760 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:54:00.43418 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:54:00.43468 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:54:07.43577 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:54:07.48997 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6962638657 2016-12-01T17:54:07.49122 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6962638657 2016-12-01T17:54:07.54994 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:54:07.54996 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:54:07.57860 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:54:07.57862 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:54:07.57863 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:54:07.57863 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:54:07.57871 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:54:07.57872 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:54:07.57873 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:54:07.57873 0.03121747] 2016-12-01T17:54:07.57881 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:54:07.57884 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:54:07.57912 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:54:07.57913 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:54:07.58042 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:54:07.58111 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:54:07.58512 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:54:14.58148 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:54:14.58793 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6942268643 2016-12-01T17:54:14.58844 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6942268643 2016-12-01T17:54:14.65062 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:54:14.65064 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:54:14.67952 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:54:14.67954 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:54:14.67955 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:54:14.67955 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:54:14.67981 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:54:14.67982 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:54:14.67982 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:54:14.67982 0.03121747] 2016-12-01T17:54:14.68021 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:54:14.68022 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:54:14.68022 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:54:14.68023 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:54:14.69045 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:54:14.69108 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:54:14.69190 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:54:21.69183 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:54:21.69598 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6919647997 2016-12-01T17:54:21.69770 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6919647997 2016-12-01T17:54:21.76957 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:54:21.76960 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:54:21.79370 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:54:21.79372 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:54:21.79373 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:54:21.79373 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:54:21.79444 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:54:21.79445 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:54:21.79445 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:54:21.79446 0.03121747] 2016-12-01T17:54:21.79455 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:54:21.79456 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:54:21.79464 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:54:21.79467 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:54:21.79628 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:54:21.79699 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:54:21.79732 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:54:28.79785 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:54:28.85587 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6930137823 2016-12-01T17:54:28.85627 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6930137823 2016-12-01T17:54:28.92396 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:54:28.92419 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:54:28.95012 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:54:28.95019 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:54:28.95031 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:54:28.95039 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:54:28.95093 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:54:28.95094 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:54:28.95095 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:54:28.95095 0.03121747] 2016-12-01T17:54:28.95105 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:54:28.95107 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:54:28.95112 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:54:28.95116 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:54:28.95259 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:54:28.95522 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:54:28.95554 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:54:35.95578 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:54:36.01893 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6916222596 2016-12-01T17:54:36.02517 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6916222596 2016-12-01T17:54:36.08223 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:54:36.08225 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:54:36.11315 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:54:36.11317 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:54:36.11318 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:54:36.11318 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:54:36.11319 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:54:36.11319 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:54:36.11320 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:54:36.11320 0.03121747] 2016-12-01T17:54:36.11321 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:54:36.11321 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:54:36.11322 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:54:36.11322 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:54:36.12482 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:54:36.13051 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:54:36.13086 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:54:43.13241 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:54:43.18298 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6987095644 2016-12-01T17:54:43.18355 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6987095644 2016-12-01T17:54:43.24667 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:54:43.24682 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:54:43.54558 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:54:43.54560 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:54:43.54561 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:54:43.54696 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:54:43.54697 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:54:43.54698 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:54:43.54698 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:54:43.54699 0.03121747] 2016-12-01T17:54:43.54699 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:54:43.54700 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:54:43.54700 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:54:43.54700 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:54:43.54847 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:54:43.54900 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:54:43.54964 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:54:50.55012 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:54:50.59270 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.693237207 2016-12-01T17:54:50.59558 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.693237207 2016-12-01T17:54:50.65634 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:54:50.65637 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:54:50.68600 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:54:50.68608 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:54:50.68617 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:54:50.68914 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:54:50.68916 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:54:50.68916 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:54:50.68916 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:54:50.68917 0.03121747] 2016-12-01T17:54:50.68917 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:54:50.68917 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:54:50.68917 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:54:50.68918 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:54:50.68974 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:54:50.69026 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:54:50.69050 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:54:57.69090 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:54:57.70753 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6959994046 2016-12-01T17:54:57.70797 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6959994046 2016-12-01T17:54:57.77475 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:54:57.77477 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:54:57.87702 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:54:57.87714 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:54:57.87728 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:54:57.87741 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:54:57.87844 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:54:57.87845 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:54:57.87846 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:54:57.87846 0.03121747] 2016-12-01T17:54:57.87859 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:54:57.87870 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:54:57.87881 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:54:57.87894 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:54:57.88424 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:54:57.88596 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:54:57.88662 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:55:04.89617 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:55:04.89943 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6970467782 2016-12-01T17:55:04.90490 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6970467782 2016-12-01T17:55:04.95875 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:55:04.95879 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:55:04.98904 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:55:04.98906 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:55:04.98906 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:55:04.98907 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:55:04.98965 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:55:04.98966 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:55:04.98967 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:55:04.98968 0.03121747] 2016-12-01T17:55:04.98995 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:55:04.98996 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:55:04.98997 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:55:04.99001 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:55:05.00830 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:55:05.01072 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:55:05.01124 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:55:12.01268 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:55:12.02354 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6907058095 2016-12-01T17:55:12.02813 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6907058095 2016-12-01T17:55:12.08439 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:55:12.08452 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:55:12.11083 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:55:12.11094 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:55:12.11106 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:55:12.11116 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:55:12.11208 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:55:12.11209 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:55:12.11210 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:55:12.11210 0.03121747] 2016-12-01T17:55:12.11222 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:55:12.11232 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:55:12.11242 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:55:12.11252 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:55:12.12277 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:55:12.12389 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:55:12.12470 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:55:19.12494 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:55:19.15056 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.692510138 2016-12-01T17:55:19.15184 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.692510138 2016-12-01T17:55:19.21255 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:55:19.21282 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:55:19.23729 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:55:19.23732 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:55:19.23732 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:55:19.23733 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:55:19.23733 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:55:19.23734 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:55:19.23734 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:55:19.23735 0.03121747] 2016-12-01T17:55:19.23735 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:55:19.23737 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:55:19.23737 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:55:19.23737 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:55:19.24937 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:55:19.25505 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:55:19.25507 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:55:26.25512 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:55:26.26162 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6956412078 2016-12-01T17:55:26.26366 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6956412078 2016-12-01T17:55:26.33134 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:55:26.33137 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:55:26.36010 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:55:26.36012 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:55:26.36013 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:55:26.36014 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:55:26.36137 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:55:26.36138 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:55:26.36138 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:55:26.36139 0.03121747] 2016-12-01T17:55:26.36139 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:55:26.36140 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:55:26.36141 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:55:26.36169 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:55:26.39629 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:55:26.39805 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:55:26.39860 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:55:33.39901 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:55:33.43838 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6969798332 2016-12-01T17:55:33.43969 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6969798332 2016-12-01T17:55:33.50277 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:55:33.50280 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:55:33.52995 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:55:33.52998 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:55:33.53095 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:55:33.53096 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:55:33.53097 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:55:33.53098 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:55:33.53100 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:55:33.53100 0.03121747] 2016-12-01T17:55:33.53106 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:55:33.53113 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:55:33.53126 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:55:33.53133 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:55:33.53998 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:55:33.54713 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:55:33.54749 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:55:40.54967 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:55:40.55062 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6938766351 2016-12-01T17:55:40.55112 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6938766351 2016-12-01T17:55:40.61486 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:55:40.61488 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:55:40.65048 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:55:40.65051 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:55:40.65218 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:55:40.65219 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:55:40.65219 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:55:40.65220 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:55:40.65221 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:55:40.65221 0.03121747] 2016-12-01T17:55:40.65221 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:55:40.65222 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:55:40.65222 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:55:40.65223 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:55:40.65546 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:55:40.65619 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:55:40.65699 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:55:47.65862 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:55:47.66038 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6933106015 2016-12-01T17:55:47.66084 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6933106015 2016-12-01T17:55:47.72416 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:55:47.72430 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:55:47.76196 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:55:47.76198 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:55:47.76199 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:55:47.76200 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:55:47.76201 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:55:47.76202 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:55:47.76202 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:55:47.76203 0.03121747] 2016-12-01T17:55:47.76203 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:55:47.76203 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:55:47.76204 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:55:47.76204 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:55:47.77073 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:55:47.78095 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:55:47.78396 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:55:54.78569 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:55:54.83285 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6968808371 2016-12-01T17:55:54.83447 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6968808371 2016-12-01T17:55:54.89438 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:55:54.89453 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:55:54.93016 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:55:54.93019 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:55:54.93019 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:55:54.93020 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:55:54.93088 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:55:54.93089 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:55:54.93090 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:55:54.93090 0.03121747] 2016-12-01T17:55:54.93090 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:55:54.93091 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:55:54.93091 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:55:54.93092 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:55:54.93241 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:55:54.93298 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:55:54.93328 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:56:01.93418 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:56:01.93891 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6911233606 2016-12-01T17:56:01.94115 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6911233606 2016-12-01T17:56:02.00040 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:56:02.00043 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:56:02.04648 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:56:02.04654 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:56:02.04661 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:56:02.04668 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:56:02.04724 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:56:02.04725 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:56:02.04726 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:56:02.04726 0.03121747] 2016-12-01T17:56:02.04732 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:56:02.04740 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:56:02.04745 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:56:02.04751 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:56:02.04880 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:56:02.04946 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:56:02.04987 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:56:09.05017 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:56:09.11202 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.697686791 2016-12-01T17:56:09.11889 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.697686791 2016-12-01T17:56:09.17490 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:56:09.17493 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:56:09.20022 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:56:09.20024 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:56:09.20025 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:56:09.20025 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:56:09.20026 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:56:09.20026 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:56:09.20027 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:56:09.20027 0.03121747] 2016-12-01T17:56:09.20028 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:56:09.20028 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:56:09.20029 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:56:09.20029 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:56:09.20497 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:56:09.20666 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:56:09.20699 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:56:16.20771 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:56:16.21883 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6935418906 2016-12-01T17:56:16.21928 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6935418906 2016-12-01T17:56:16.28254 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:56:16.28256 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:56:16.31181 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:56:16.31183 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:56:16.31183 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:56:16.31184 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:56:16.31184 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:56:16.31185 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:56:16.31185 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:56:16.31186 0.03121747] 2016-12-01T17:56:16.31186 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:56:16.31187 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:56:16.31350 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:56:16.31351 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:56:16.31440 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:56:16.31521 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:56:16.31829 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:56:23.31943 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:56:23.38337 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6961352735 2016-12-01T17:56:23.38455 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6961352735 2016-12-01T17:56:23.44515 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:56:23.44524 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:56:23.47025 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:56:23.47028 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:56:23.47118 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:56:23.47121 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:56:23.47189 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:56:23.47190 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:56:23.47191 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:56:23.47191 0.03121747] 2016-12-01T17:56:23.47192 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:56:23.47192 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:56:23.47193 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:56:23.47193 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:56:23.48722 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:56:23.49515 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:56:23.49564 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:56:30.49778 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:56:30.55319 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6953279839 2016-12-01T17:56:30.55777 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6953279839 2016-12-01T17:56:30.61690 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:56:30.61694 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:56:30.64141 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:56:30.64143 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:56:30.64144 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:56:30.64144 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:56:30.64145 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:56:30.64145 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:56:30.64146 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:56:30.64146 0.03121747] 2016-12-01T17:56:30.64147 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:56:30.64147 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:56:30.64148 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:56:30.64148 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:56:30.65318 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:56:30.65774 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:56:30.65809 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:56:37.65830 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:56:37.72062 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6964753726 2016-12-01T17:56:37.72120 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6964753726 2016-12-01T17:56:37.78565 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:56:37.78567 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:56:37.84118 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:56:37.84125 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:56:37.84135 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:56:37.84145 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:56:37.84201 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:56:37.84202 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:56:37.84202 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:56:37.84203 0.03121747] 2016-12-01T17:56:37.84214 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:56:37.84219 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:56:37.84243 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:56:37.84244 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:56:37.84439 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:56:37.84504 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:56:37.84534 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:56:44.84602 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:56:44.89130 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6919498615 2016-12-01T17:56:44.89449 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6919498615 2016-12-01T17:56:44.95250 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:56:44.95262 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:56:45.03830 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:56:45.03832 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:56:45.03832 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:56:45.03833 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:56:45.03833 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:56:45.03834 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:56:45.03834 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:56:45.03835 0.03121747] 2016-12-01T17:56:45.03835 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:56:45.03836 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:56:45.03836 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:56:45.03836 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:56:45.03936 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:56:45.04000 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:56:45.04032 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:56:52.04071 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:56:52.06285 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6942088105 2016-12-01T17:56:52.06431 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6942088105 2016-12-01T17:56:52.12614 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:56:52.12615 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:56:52.15678 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:56:52.15680 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:56:52.15681 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:56:52.15681 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:56:52.15682 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:56:52.15682 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:56:52.15683 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:56:52.15683 0.03121747] 2016-12-01T17:56:52.15684 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:56:52.15684 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:56:52.15684 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:56:52.15685 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:56:52.16259 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:56:52.16583 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:56:52.16895 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:56:59.16664 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:56:59.16851 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6875920055 2016-12-01T17:56:59.16941 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6875920055 2016-12-01T17:56:59.23233 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:56:59.23245 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:56:59.27198 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:56:59.27199 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:56:59.27199 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:56:59.27200 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:56:59.27200 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:56:59.27200 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:56:59.27201 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:56:59.27201 0.03121747] 2016-12-01T17:56:59.27201 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:56:59.27202 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:56:59.27202 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:56:59.27202 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:56:59.28219 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:56:59.28472 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:56:59.28493 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:57:06.28518 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:57:06.33653 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6941219742 2016-12-01T17:57:06.33787 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6941219742 2016-12-01T17:57:06.40126 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:57:06.40128 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:57:06.45150 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:57:06.45152 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:57:06.45153 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:57:06.45153 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:57:06.45154 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:57:06.45154 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:57:06.45155 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:57:06.45155 0.03121747] 2016-12-01T17:57:06.45156 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:57:06.45157 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:57:06.45183 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:57:06.45186 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:57:06.45278 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:57:06.45343 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:57:06.45375 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:57:13.45488 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:57:13.49324 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6937109502 2016-12-01T17:57:13.49438 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6937109502 2016-12-01T17:57:13.55686 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:57:13.55689 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:57:13.59424 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:57:13.59432 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:57:13.59585 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:57:13.59586 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:57:13.59587 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:57:13.59587 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:57:13.59588 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:57:13.59588 0.03121747] 2016-12-01T17:57:13.59589 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:57:13.59589 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:57:13.59589 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:57:13.59590 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:57:13.59679 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:57:13.59747 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:57:13.59776 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:57:20.59813 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:57:20.65951 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6894956342 2016-12-01T17:57:20.65988 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6894956342 2016-12-01T17:57:20.72002 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:57:20.72011 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:57:20.74898 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:57:20.74905 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:57:20.74989 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:57:20.74990 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:57:20.75053 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:57:20.75054 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:57:20.75055 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:57:20.75057 0.03121747] 2016-12-01T17:57:20.75058 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:57:20.75058 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:57:20.75059 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:57:20.75060 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:57:20.76619 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:57:20.77061 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:57:20.77097 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:57:27.77122 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:57:27.81813 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6908959983 2016-12-01T17:57:27.81860 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6908959983 2016-12-01T17:57:27.88297 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:57:27.88299 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:57:28.42744 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:57:28.42755 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:57:28.42767 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:57:28.42777 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:57:28.42870 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:57:28.42871 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:57:28.42871 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:57:28.42871 0.03121747] 2016-12-01T17:57:28.42878 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:57:28.42887 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:57:28.42897 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:57:28.42903 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:57:28.44044 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:57:28.44581 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:57:28.44615 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:57:35.44625 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:57:35.49393 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.693711721 2016-12-01T17:57:35.49557 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.693711721 2016-12-01T17:57:35.55463 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:57:35.55465 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:57:35.58057 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:57:35.58163 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:57:35.58165 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:57:35.58165 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:57:35.58221 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:57:35.58224 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:57:35.58224 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:57:35.58225 0.03121747] 2016-12-01T17:57:35.58225 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:57:35.58226 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:57:35.58226 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:57:35.58227 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:57:35.58930 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:57:35.59002 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:57:35.59055 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:57:42.59083 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:57:42.61439 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6932538051 2016-12-01T17:57:42.61591 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6932538051 2016-12-01T17:57:42.67732 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:57:42.67735 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:57:42.70316 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:57:42.70319 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:57:42.70321 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:57:42.70322 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:57:42.70381 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:57:42.70383 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:57:42.70383 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:57:42.70384 0.03121747] 2016-12-01T17:57:42.70392 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:57:42.70397 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:57:42.70426 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:57:42.70427 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:57:42.70866 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:57:42.71412 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:57:42.71601 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:57:49.71467 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:57:49.72159 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.696385524 2016-12-01T17:57:49.72220 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.696385524 2016-12-01T17:57:49.78498 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:57:49.78516 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:57:49.82508 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:57:49.82510 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:57:49.82512 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:57:49.82513 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:57:49.82588 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:57:49.82590 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:57:49.82590 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:57:49.82591 0.03121747] 2016-12-01T17:57:49.82602 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:57:49.82612 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:57:49.82622 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:57:49.82632 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:57:49.82776 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:57:49.82852 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:57:49.82899 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:57:56.83301 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:57:56.89555 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6972214575 2016-12-01T17:57:56.89646 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6972214575 2016-12-01T17:57:56.95511 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:57:56.95514 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:57:56.98867 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:57:56.98869 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:57:56.98869 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:57:56.98869 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:57:56.98870 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:57:56.98870 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:57:56.98871 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:57:56.98871 0.03121747] 2016-12-01T17:57:56.98871 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:57:56.98872 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:57:56.98873 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:57:56.98873 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:57:56.98960 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:57:56.99009 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:57:56.99050 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:58:03.99195 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:58:04.01166 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6945201502 2016-12-01T17:58:04.01434 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6945201502 2016-12-01T17:58:04.06317 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:58:04.06349 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:58:04.08981 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:58:04.08983 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:58:04.08984 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:58:04.08984 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:58:04.08985 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:58:04.08985 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:58:04.08985 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:58:04.08986 0.03121747] 2016-12-01T17:58:04.08986 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:58:04.08987 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:58:04.08987 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:58:04.08987 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:58:04.09112 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:58:04.09255 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:58:04.09277 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:58:11.09331 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:58:11.11592 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.7005321142 2016-12-01T17:58:11.11703 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.7005321142 2016-12-01T17:58:11.17457 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:58:11.17459 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:58:11.20340 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:58:11.20342 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:58:11.20342 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:58:11.20343 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:58:11.20343 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:58:11.20344 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:58:11.20344 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:58:11.20345 0.03121747] 2016-12-01T17:58:11.20345 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:58:11.20346 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:58:11.20346 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:58:11.20347 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:58:11.20811 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:58:11.21527 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:58:11.21559 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:58:18.21613 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:58:18.23328 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.695916588 2016-12-01T17:58:18.24318 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.695916588 2016-12-01T17:58:18.29614 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:58:18.29618 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:58:18.34168 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:58:18.34170 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:58:18.34170 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:58:18.34171 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:58:18.34171 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:58:18.34172 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:58:18.34172 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:58:18.34173 0.03121747] 2016-12-01T17:58:18.34173 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:58:18.34174 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:58:18.34174 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:58:18.34174 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:58:18.35403 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:58:18.35457 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:58:18.35480 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:58:25.35795 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:58:25.40011 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6954286454 2016-12-01T17:58:25.40330 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6954286454 2016-12-01T17:58:25.46122 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:58:25.46124 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:58:25.49580 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:58:25.49582 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:58:25.49583 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:58:25.49584 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:58:25.49584 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:58:25.49585 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:58:25.49585 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:58:25.49586 0.03121747] 2016-12-01T17:58:25.49586 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:58:25.49588 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:58:25.49591 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:58:25.49601 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:58:25.50677 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:58:25.50784 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:58:25.51071 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:58:32.51103 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:58:32.56857 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6971980526 2016-12-01T17:58:32.56984 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6971980526 2016-12-01T17:58:32.63452 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:58:32.63516 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:58:32.67842 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:58:32.67849 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:58:32.67856 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:58:32.67863 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:58:32.67967 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:58:32.67968 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:58:32.67968 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:58:32.67969 0.03121747] 2016-12-01T17:58:32.67973 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:58:32.67980 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:58:32.68323 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:58:32.68324 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:58:32.68698 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:58:32.68770 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:58:32.68813 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:58:39.68899 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:58:39.72998 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6954997192 2016-12-01T17:58:39.73389 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6954997192 2016-12-01T17:58:39.79611 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:58:39.79613 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:58:39.82465 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:58:39.82467 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:58:39.82467 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:58:39.82468 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:58:39.82468 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:58:39.82469 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:58:39.82469 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:58:39.82470 0.03121747] 2016-12-01T17:58:39.82470 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:58:39.82471 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:58:39.82471 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:58:39.82472 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:58:39.82608 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:58:39.82673 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:58:39.82701 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:58:46.82758 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:58:46.83660 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.699113751 2016-12-01T17:58:46.83693 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.699113751 2016-12-01T17:58:46.89938 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:58:46.89954 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:58:46.93399 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:58:46.93411 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:58:46.93422 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:58:46.93434 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:58:46.93531 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:58:46.93532 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:58:46.93533 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:58:46.93533 0.03121747] 2016-12-01T17:58:46.93545 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:58:46.93555 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:58:46.93565 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:58:46.93576 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:58:46.94349 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:58:46.94416 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:58:46.94463 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:58:53.94490 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:58:53.95302 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.7054023253 2016-12-01T17:58:53.95440 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.7054023253 2016-12-01T17:58:54.01712 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:58:54.01715 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:58:54.05353 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:58:54.05358 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:58:54.05365 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:58:54.05496 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:58:54.05497 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:58:54.05497 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:58:54.05498 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:58:54.05498 0.03121747] 2016-12-01T17:58:54.05499 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:58:54.05499 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:58:54.05499 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:58:54.05500 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:58:54.05840 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:58:54.06710 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:58:54.06746 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:59:01.06936 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:59:01.12021 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6939977286 2016-12-01T17:59:01.12353 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6939977286 2016-12-01T17:59:01.18285 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:59:01.18297 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:59:01.21300 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:59:01.21312 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:59:01.21324 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:59:01.21335 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:59:01.21432 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:59:01.21433 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:59:01.21433 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:59:01.21434 0.03121747] 2016-12-01T17:59:01.21446 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:59:01.21456 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:59:01.21467 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:59:01.21477 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:59:01.21990 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:59:01.22067 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:59:01.22109 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:59:08.22157 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:59:08.23189 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.7000090866 2016-12-01T17:59:08.23260 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.7000090866 2016-12-01T17:59:08.29484 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:59:08.29486 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:59:08.37326 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:59:08.37328 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:59:08.37329 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:59:08.37329 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:59:08.37330 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:59:08.37331 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:59:08.37331 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:59:08.37332 0.03121747] 2016-12-01T17:59:08.37332 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:59:08.37334 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:59:08.37335 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:59:08.37335 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:59:08.37833 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:59:08.37955 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:59:08.38053 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:59:15.38004 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:59:15.39703 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6985080376 2016-12-01T17:59:15.39747 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6985080376 2016-12-01T17:59:15.45686 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:59:15.45701 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:59:15.57546 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:59:15.57548 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:59:15.57549 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:59:15.57549 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:59:15.57576 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:59:15.57577 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:59:15.57577 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:59:15.57578 0.03121747] 2016-12-01T17:59:15.57586 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:59:15.57593 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:59:15.57601 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:59:15.57609 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:59:15.57977 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:59:15.58079 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:59:15.58108 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:59:22.58157 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:59:22.63212 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.698806477 2016-12-01T17:59:22.63413 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.698806477 2016-12-01T17:59:22.69522 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:59:22.69524 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:59:22.72347 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:59:22.72358 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:59:22.72503 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:59:22.72504 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:59:22.72504 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:59:22.72505 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:59:22.72507 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:59:22.72507 0.03121747] 2016-12-01T17:59:22.72508 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:59:22.72508 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:59:22.72509 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:59:22.72509 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:59:22.73117 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:59:22.73184 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:59:22.73215 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:59:29.73236 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:59:29.74036 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6985716469 2016-12-01T17:59:29.74118 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6985716469 2016-12-01T17:59:29.80317 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:59:29.80320 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:59:29.84037 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:59:29.84040 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:59:29.84040 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:59:29.84041 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:59:29.84041 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:59:29.84041 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:59:29.84042 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:59:29.84042 0.03121747] 2016-12-01T17:59:29.84042 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:59:29.84043 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:59:29.84043 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:59:29.84065 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:59:29.84324 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:59:29.84793 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:59:29.84822 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:59:36.84902 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:59:36.85428 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6998303088 2016-12-01T17:59:36.85576 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6998303088 2016-12-01T17:59:36.91772 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:59:36.91774 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:59:36.94154 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:59:36.94156 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:59:36.94156 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:59:36.94158 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:59:36.94159 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:59:36.94159 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:59:36.94160 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:59:36.94160 0.03121747] 2016-12-01T17:59:36.94161 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:59:36.94161 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:59:36.94162 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:59:36.94162 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:59:36.94349 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:59:36.94475 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:59:36.94496 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:59:43.94530 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:59:43.95821 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.699662619 2016-12-01T17:59:43.95914 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.699662619 2016-12-01T17:59:44.02102 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:59:44.02105 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:59:44.06637 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:59:44.06645 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:59:44.06654 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:59:44.06662 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:59:44.06758 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:59:44.06759 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:59:44.06759 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:59:44.06760 0.03121747] 2016-12-01T17:59:44.06767 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:59:44.06890 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:59:44.06891 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:59:44.06892 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:59:44.07383 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:59:44.07449 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:59:44.07581 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:59:51.07674 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:59:51.12974 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6942867943 2016-12-01T17:59:51.13168 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6942867943 2016-12-01T17:59:51.19569 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:59:51.19572 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:59:51.22315 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:59:51.22317 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:59:51.22317 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:59:51.22318 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:59:51.22318 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:59:51.22322 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:59:51.22323 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:59:51.22324 0.03121747] 2016-12-01T17:59:51.22324 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:59:51.22325 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:59:51.22325 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:59:51.22326 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:59:51.24738 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:59:51.25290 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:59:51.25342 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T17:59:58.25552 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T17:59:58.30592 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6998757724 2016-12-01T17:59:58.30641 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6998757724 2016-12-01T17:59:58.36890 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T17:59:58.36893 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T17:59:58.44081 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T17:59:58.44087 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T17:59:58.44094 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T17:59:58.44101 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T17:59:58.44156 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T17:59:58.44157 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T17:59:58.44157 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T17:59:58.44158 0.03121747] 2016-12-01T17:59:58.44164 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T17:59:58.44169 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T17:59:58.44176 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T17:59:58.44182 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T17:59:58.44671 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T17:59:58.44926 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T17:59:58.45003 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:00:05.44979 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:00:05.49396 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6963260012 2016-12-01T18:00:05.49455 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6963260012 2016-12-01T18:00:05.55672 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:00:05.55719 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:00:05.58549 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:00:05.58560 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:00:05.58571 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:00:05.58581 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:00:05.58668 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:00:05.58668 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:00:05.58669 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:00:05.58669 0.03121747] 2016-12-01T18:00:05.58680 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:00:05.58689 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:00:05.58699 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:00:05.58708 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:00:05.59265 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:00:05.59327 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:00:05.59348 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:00:12.59586 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:00:12.64955 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6937987035 2016-12-01T18:00:12.65187 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6937987035 2016-12-01T18:00:12.71373 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:00:12.71414 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:00:12.74380 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:00:12.74387 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:00:12.74397 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:00:12.74406 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:00:12.74499 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:00:12.74500 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:00:12.74501 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:00:12.74501 0.03121747] 2016-12-01T18:00:12.74509 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:00:12.74516 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:00:12.74523 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:00:12.74531 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:00:12.75790 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:00:12.76291 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:00:12.76503 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:00:19.76540 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:00:19.81653 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6984995872 2016-12-01T18:00:19.81831 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6984995872 2016-12-01T18:00:19.87997 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:00:19.88001 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:00:19.91227 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:00:19.91229 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:00:19.91229 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:00:19.91230 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:00:19.91230 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:00:19.91231 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:00:19.91231 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:00:19.91232 0.03121747] 2016-12-01T18:00:19.91232 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:00:19.91232 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:00:19.91233 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:00:19.91234 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:00:19.91739 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:00:19.91790 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:00:19.91990 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:00:26.92028 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:00:26.92771 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6953510475 2016-12-01T18:00:26.93026 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6953510475 2016-12-01T18:00:26.98867 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:00:26.98869 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:00:27.00643 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:00:27.00650 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:00:27.00657 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:00:27.00664 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:00:27.00728 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:00:27.00729 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:00:27.00730 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:00:27.00730 0.03121747] 2016-12-01T18:00:27.00736 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:00:27.00742 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:00:27.00771 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:00:27.00772 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:00:27.01653 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:00:27.01713 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:00:27.01901 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:00:34.01838 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:00:34.03359 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6938935356 2016-12-01T18:00:34.03931 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6938935356 2016-12-01T18:00:34.08942 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:00:34.08944 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:00:34.11536 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:00:34.11551 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:00:34.11563 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:00:34.11574 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:00:34.11674 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:00:34.11675 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:00:34.11675 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:00:34.11676 0.03121747] 2016-12-01T18:00:34.11688 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:00:34.11699 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:00:34.11710 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:00:34.11721 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:00:34.11937 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:00:34.12018 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:00:34.12053 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:00:41.12240 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:00:41.12921 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6912535688 2016-12-01T18:00:41.13010 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6912535688 2016-12-01T18:00:41.19050 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:00:41.19063 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:00:41.21626 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:00:41.21628 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:00:41.21628 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:00:41.21629 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:00:41.21740 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:00:41.21741 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:00:41.21742 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:00:41.21742 0.03121747] 2016-12-01T18:00:41.21743 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:00:41.21743 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:00:41.21744 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:00:41.21744 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:00:41.22202 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:00:41.22252 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:00:41.22273 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:00:48.22322 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:00:48.24370 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6956414835 2016-12-01T18:00:48.25129 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6956414835 2016-12-01T18:00:48.30109 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:00:48.30121 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:00:48.37631 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:00:48.37643 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:00:48.37656 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:00:48.37668 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:00:48.37765 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:00:48.37766 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:00:48.37767 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:00:48.37768 0.03121747] 2016-12-01T18:00:48.37780 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:00:48.37791 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:00:48.37802 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:00:48.37813 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:00:48.38408 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:00:48.38590 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:00:48.38641 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:00:55.39494 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:00:55.41285 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6990874534 2016-12-01T18:00:55.41502 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6990874534 2016-12-01T18:00:55.47621 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:00:55.47623 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:00:55.50343 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:00:55.50345 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:00:55.50346 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:00:55.50346 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:00:55.50347 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:00:55.50348 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:00:55.50348 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:00:55.50349 0.03121747] 2016-12-01T18:00:55.50349 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:00:55.50350 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:00:55.50350 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:00:55.50352 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:00:55.50465 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:00:55.50785 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:00:55.50833 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:01:02.50867 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:01:02.52225 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6943868018 2016-12-01T18:01:02.52455 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6943868018 2016-12-01T18:01:02.58236 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:01:02.58238 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:01:02.60796 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:01:02.60798 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:01:02.60798 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:01:02.60798 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:01:02.60799 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:01:02.60799 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:01:02.60800 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:01:02.60800 0.03121747] 2016-12-01T18:01:02.60800 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:01:02.60801 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:01:02.60801 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:01:02.60802 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:01:02.60888 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:01:02.60940 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:01:02.60961 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:01:09.60974 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:01:09.62275 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6981256817 2016-12-01T18:01:09.62613 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6981256817 2016-12-01T18:01:09.68668 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:01:09.68670 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:01:09.71521 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:01:09.71523 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:01:09.71524 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:01:09.71524 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:01:09.71525 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:01:09.71525 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:01:09.71525 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:01:09.71527 0.03121747] 2016-12-01T18:01:09.71527 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:01:09.71528 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:01:09.71528 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:01:09.71529 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:01:09.71616 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:01:09.71667 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:01:09.71688 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:01:16.71721 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:01:16.73138 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.7003305316 2016-12-01T18:01:16.73181 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.7003305316 2016-12-01T18:01:16.79455 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:01:16.79470 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:01:16.82562 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:01:16.82566 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:01:16.82572 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:01:16.82577 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:01:16.82625 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:01:16.82626 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:01:16.82626 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:01:16.82627 0.03121747] 2016-12-01T18:01:16.82637 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:01:16.82762 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:01:16.82763 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:01:16.82763 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:01:16.83516 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:01:16.83600 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:01:16.83974 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:01:23.84007 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:01:23.84346 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6993833753 2016-12-01T18:01:23.84640 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6993833753 2016-12-01T18:01:23.90917 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:01:23.90920 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:01:23.94003 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:01:23.94008 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:01:23.94017 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:01:23.94024 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:01:23.94088 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:01:23.94090 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:01:23.94091 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:01:23.94091 0.03121747] 2016-12-01T18:01:23.94096 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:01:23.94125 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:01:23.94126 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:01:23.94127 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:01:23.94503 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:01:23.94601 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:01:23.94616 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:01:30.94824 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:01:31.01719 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.696465896 2016-12-01T18:01:31.01799 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.696465896 2016-12-01T18:01:31.08254 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:01:31.08256 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:01:31.11058 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:01:31.11061 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:01:31.11061 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:01:31.11062 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:01:31.11062 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:01:31.11063 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:01:31.11063 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:01:31.11065 0.03121747] 2016-12-01T18:01:31.11065 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:01:31.11066 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:01:31.11066 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:01:31.11067 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:01:31.12016 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:01:31.12089 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:01:31.12116 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:01:38.12141 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:01:38.14030 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.7008947333 2016-12-01T18:01:38.14308 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.7008947333 2016-12-01T18:01:38.19549 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:01:38.19578 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:01:38.40497 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:01:38.40499 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:01:38.40501 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:01:38.40501 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:01:38.40502 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:01:38.40502 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:01:38.40503 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:01:38.40503 0.03121747] 2016-12-01T18:01:38.40504 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:01:38.40504 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:01:38.40506 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:01:38.40507 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:01:38.40589 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:01:38.40715 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:01:38.40747 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:01:45.40874 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:01:45.41697 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6953138003 2016-12-01T18:01:45.41914 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6953138003 2016-12-01T18:01:45.47946 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:01:45.47948 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:01:45.50727 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:01:45.50735 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:01:45.50744 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:01:45.50752 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:01:45.50845 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:01:45.50846 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:01:45.50847 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:01:45.50847 0.03121747] 2016-12-01T18:01:45.50854 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:01:45.50861 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:01:45.50869 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:01:45.50877 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:01:45.50993 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:01:45.51062 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:01:45.51076 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:01:52.51179 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:01:52.52473 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6961954046 2016-12-01T18:01:52.52557 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6961954046 2016-12-01T18:01:52.58712 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:01:52.58726 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:01:52.61767 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:01:52.61769 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:01:52.61770 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:01:52.61770 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:01:52.61831 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:01:52.61832 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:01:52.61832 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:01:52.61833 0.03121747] 2016-12-01T18:01:52.61833 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:01:52.61834 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:01:52.61834 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:01:52.61834 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:01:52.62023 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:01:52.62861 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:01:52.63047 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:01:59.62977 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:01:59.69070 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6996542582 2016-12-01T18:01:59.69449 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6996542582 2016-12-01T18:01:59.75436 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:01:59.75438 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:01:59.79561 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:01:59.79567 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:01:59.79575 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:01:59.79582 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:01:59.79664 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:01:59.79665 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:01:59.79665 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:01:59.79666 0.03121747] 2016-12-01T18:01:59.79678 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:01:59.79687 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:01:59.79698 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:01:59.79707 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:01:59.79985 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:01:59.80154 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:01:59.80438 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:02:06.80201 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:02:06.80608 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6966462972 2016-12-01T18:02:06.80663 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6966462972 2016-12-01T18:02:06.86728 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:02:06.87027 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:02:06.94330 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:02:06.94332 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:02:06.94333 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:02:06.94333 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:02:06.94456 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:02:06.94457 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:02:06.94457 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:02:06.94458 0.03121747] 2016-12-01T18:02:06.94458 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:02:06.94459 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:02:06.94459 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:02:06.94460 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:02:06.94552 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:02:06.95227 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:02:06.95297 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:02:13.95330 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:02:13.97189 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6983404716 2016-12-01T18:02:13.97261 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6983404716 2016-12-01T18:02:14.03724 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:02:14.03726 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:02:14.06589 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:02:14.06591 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:02:14.06592 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:02:14.06592 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:02:14.06593 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:02:14.06593 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:02:14.06593 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:02:14.06594 0.03121747] 2016-12-01T18:02:14.06594 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:02:14.06595 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:02:14.06595 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:02:14.06595 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:02:14.06706 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:02:14.06775 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:02:14.06815 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:02:21.06844 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:02:21.13585 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.7031012496 2016-12-01T18:02:21.14036 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.7031012496 2016-12-01T18:02:21.19409 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:02:21.19411 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:02:21.22168 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:02:21.22170 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:02:21.22171 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:02:21.22171 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:02:21.22181 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:02:21.22182 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:02:21.22183 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:02:21.22183 0.03121747] 2016-12-01T18:02:21.22199 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:02:21.22199 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:02:21.22205 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:02:21.22213 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:02:21.22824 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:02:21.22897 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:02:21.22943 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:02:28.22976 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:02:28.24023 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.7025070836 2016-12-01T18:02:28.24161 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.7025070836 2016-12-01T18:02:28.30295 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:02:28.30308 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:02:28.32652 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:02:28.32655 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:02:28.32662 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:02:28.32668 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:02:28.32933 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:02:28.32934 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:02:28.32935 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:02:28.32935 0.03121747] 2016-12-01T18:02:28.32935 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:02:28.32936 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:02:28.32936 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:02:28.32937 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:02:28.32995 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:02:28.33057 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:02:28.33090 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:02:35.33123 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:02:35.34918 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6990519097 2016-12-01T18:02:35.34984 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6990519097 2016-12-01T18:02:35.41719 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:02:35.41733 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:02:35.44115 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:02:35.44126 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:02:35.44129 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:02:35.44134 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:02:35.44183 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:02:35.44183 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:02:35.44184 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:02:35.44184 0.03121747] 2016-12-01T18:02:35.44188 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:02:35.44192 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:02:35.44196 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:02:35.44200 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:02:35.44308 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:02:35.44419 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:02:35.44444 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:02:42.44466 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:02:42.45653 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.7024102608 2016-12-01T18:02:42.45718 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.7024102608 2016-12-01T18:02:42.51990 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:02:42.51993 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:02:42.54133 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:02:42.54135 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:02:42.54136 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:02:42.54137 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:02:42.54247 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:02:42.54248 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:02:42.54248 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:02:42.54249 0.03121747] 2016-12-01T18:02:42.54249 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:02:42.54250 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:02:42.54250 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:02:42.54251 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:02:42.54371 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:02:42.54422 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:02:42.54442 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:02:49.54466 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:02:49.55707 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.7015004838 2016-12-01T18:02:49.55838 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.7015004838 2016-12-01T18:02:49.61923 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:02:49.61930 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:02:49.64907 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:02:49.64909 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:02:49.64910 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:02:49.64910 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:02:49.64911 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:02:49.64911 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:02:49.64912 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:02:49.64912 0.03121747] 2016-12-01T18:02:49.64912 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:02:49.64913 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:02:49.64913 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:02:49.64914 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:02:49.65293 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:02:49.65955 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:02:49.66264 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:02:56.66266 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:02:56.72267 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6942570109 2016-12-01T18:02:56.73157 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6942570109 2016-12-01T18:02:56.78491 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:02:56.78512 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:02:56.81182 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:02:56.81195 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:02:56.81206 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:02:56.81219 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:02:56.81290 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:02:56.81291 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:02:56.81291 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:02:56.81291 0.03121747] 2016-12-01T18:02:56.81297 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:02:56.81303 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:02:56.81310 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:02:56.81316 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:02:56.81798 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:02:56.81850 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:02:56.81874 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:03:03.81898 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:03:03.83019 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.7022234536 2016-12-01T18:03:03.83068 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.7022234536 2016-12-01T18:03:03.89312 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:03:03.89314 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:03:03.91908 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:03:03.91912 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:03:03.91922 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:03:03.92054 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:03:03.92055 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:03:03.92055 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:03:03.92056 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:03:03.92056 0.03121747] 2016-12-01T18:03:03.92057 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:03:03.92057 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:03:03.92058 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:03:03.92058 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:03:03.92631 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:03:03.92734 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:03:03.93067 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:03:10.92810 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:03:10.93243 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.694237784 2016-12-01T18:03:10.93307 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.694237784 2016-12-01T18:03:10.99291 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:03:10.99302 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:03:11.02507 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:03:11.02511 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:03:11.02661 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:03:11.02662 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:03:11.02662 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:03:11.02663 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:03:11.02664 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:03:11.02665 0.03121747] 2016-12-01T18:03:11.02665 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:03:11.02665 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:03:11.02666 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:03:11.02666 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:03:11.02755 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:03:11.02825 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:03:11.02854 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:03:18.03221 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:03:18.03689 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6954145843 2016-12-01T18:03:18.03783 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6954145843 2016-12-01T18:03:18.09974 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:03:18.10008 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:03:18.49430 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:03:18.49432 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:03:18.49433 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:03:18.49433 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:03:18.49434 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:03:18.49435 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:03:18.49435 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:03:18.49436 0.03121747] 2016-12-01T18:03:18.49436 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:03:18.49437 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:03:18.49437 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:03:18.49438 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:03:18.50767 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:03:18.51041 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:03:18.51312 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:03:25.51983 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:03:25.53077 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6950262182 2016-12-01T18:03:25.53141 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6950262182 2016-12-01T18:03:25.58866 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:03:25.58879 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:03:25.62080 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:03:25.62082 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:03:25.62083 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:03:25.62084 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:03:25.62085 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:03:25.62086 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:03:25.62087 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:03:25.62087 0.03121747] 2016-12-01T18:03:25.62087 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:03:25.62088 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:03:25.62088 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:03:25.62089 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:03:25.63025 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:03:25.63312 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:03:25.63446 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:03:32.63467 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:03:32.64158 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6962486276 2016-12-01T18:03:32.64224 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6962486276 2016-12-01T18:03:32.70510 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:03:32.70513 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:03:32.73195 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:03:32.73197 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:03:32.73197 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:03:32.73198 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:03:32.73320 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:03:32.73321 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:03:32.73321 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:03:32.73322 0.03121747] 2016-12-01T18:03:32.73322 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:03:32.73323 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:03:32.73323 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:03:32.73324 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:03:32.73937 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:03:32.74425 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:03:32.74454 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:03:39.74485 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:03:39.81193 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6949926977 2016-12-01T18:03:39.81248 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6949926977 2016-12-01T18:03:39.87446 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:03:39.87585 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:03:39.90313 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:03:39.90317 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:03:39.90317 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:03:39.90318 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:03:39.90318 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:03:39.90319 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:03:39.90320 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:03:39.90321 0.03121747] 2016-12-01T18:03:39.90321 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:03:39.90322 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:03:39.90323 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:03:39.90332 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:03:39.90668 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:03:39.92263 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:03:39.92402 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:03:46.92449 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:03:46.98931 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6950146527 2016-12-01T18:03:46.99131 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6950146527 2016-12-01T18:03:47.05509 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:03:47.05511 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:03:47.08640 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:03:47.08642 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:03:47.08642 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:03:47.08643 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:03:47.08644 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:03:47.08644 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:03:47.08645 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:03:47.08645 0.03121747] 2016-12-01T18:03:47.08652 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:03:47.08662 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:03:47.08673 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:03:47.08682 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:03:47.09008 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:03:47.09235 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:03:47.09267 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:03:54.09314 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:03:54.14648 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6954369975 2016-12-01T18:03:54.14909 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6954369975 2016-12-01T18:03:54.20754 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:03:54.20769 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:03:54.25080 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:03:54.25083 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:03:54.25083 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:03:54.25084 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:03:54.25179 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:03:54.25180 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:03:54.25181 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:03:54.25182 0.03121747] 2016-12-01T18:03:54.25195 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:03:54.25205 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:03:54.25218 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:03:54.25230 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:03:54.25375 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:03:54.25505 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:03:54.26338 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:04:01.26572 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:04:01.32156 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6946796971 2016-12-01T18:04:01.32218 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6946796971 2016-12-01T18:04:01.38412 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:04:01.38414 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:04:01.41676 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:04:01.41678 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:04:01.41679 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:04:01.41679 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:04:01.41680 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:04:01.41680 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:04:01.41681 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:04:01.41681 0.03121747] 2016-12-01T18:04:01.41682 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:04:01.41682 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:04:01.41683 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:04:01.41683 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:04:01.41861 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:04:01.42109 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:04:01.42156 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:04:08.42465 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:04:08.43420 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.693328167 2016-12-01T18:04:08.43484 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.693328167 2016-12-01T18:04:08.49901 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:04:08.49905 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:04:08.60801 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:04:08.60804 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:04:08.60804 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:04:08.60804 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:04:08.60937 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:04:08.60938 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:04:08.60939 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:04:08.60940 0.03121747] 2016-12-01T18:04:08.60940 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:04:08.60941 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:04:08.60941 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:04:08.60941 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:04:08.61789 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:04:08.62385 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:04:08.62416 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:04:15.62470 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:04:15.67609 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6947894086 2016-12-01T18:04:15.67659 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6947894086 2016-12-01T18:04:15.74006 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:04:15.74008 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:04:15.77278 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:04:15.77280 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:04:15.77280 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:04:15.77281 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:04:15.77281 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:04:15.77281 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:04:15.77282 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:04:15.77282 0.03121747] 2016-12-01T18:04:15.77283 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:04:15.77283 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:04:15.77284 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:04:15.77284 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:04:15.77417 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:04:15.77555 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:04:15.77586 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:04:22.77635 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:04:22.80335 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6936062637 2016-12-01T18:04:22.81062 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6936062637 2016-12-01T18:04:22.85920 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:04:22.85923 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:04:23.35059 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:04:23.35061 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:04:23.35062 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:04:23.35062 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:04:23.35063 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:04:23.35063 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:04:23.35064 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:04:23.35064 0.03121747] 2016-12-01T18:04:23.35065 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:04:23.35065 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:04:23.35066 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:04:23.35066 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:04:23.35285 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:04:23.35627 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:04:23.35665 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:04:30.35691 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:04:30.39675 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6868441354 2016-12-01T18:04:30.39756 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6868441354 2016-12-01T18:04:30.45973 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:04:30.46036 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:04:30.49921 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:04:30.49927 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:04:30.50066 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:04:30.50067 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:04:30.50068 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:04:30.50068 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:04:30.50069 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:04:30.50069 0.03121747] 2016-12-01T18:04:30.50070 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:04:30.50070 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:04:30.50071 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:04:30.50071 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:04:30.51309 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:04:30.51665 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:04:30.51695 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:04:37.51774 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:04:37.57499 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.699643158 2016-12-01T18:04:37.57576 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.699643158 2016-12-01T18:04:37.64198 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:04:37.64200 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:04:37.67997 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:04:37.67999 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:04:37.67999 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:04:37.68000 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:04:37.68007 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:04:37.68008 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:04:37.68008 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:04:37.68009 0.03121747] 2016-12-01T18:04:37.68026 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:04:37.68027 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:04:37.68057 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:04:37.68059 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:04:37.69304 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:04:37.69423 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:04:37.69452 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:04:44.69483 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:04:44.70233 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6886050551 2016-12-01T18:04:44.70499 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6886050551 2016-12-01T18:04:44.76564 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:04:44.76566 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:04:44.79541 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:04:44.79542 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:04:44.79543 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:04:44.79543 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:04:44.79604 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:04:44.79605 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:04:44.79605 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:04:44.79606 0.03121747] 2016-12-01T18:04:44.79606 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:04:44.79607 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:04:44.79607 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:04:44.79609 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:04:44.79723 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:04:44.79771 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:04:44.79800 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:04:51.79838 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:04:51.81762 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6918514388 2016-12-01T18:04:51.81966 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6918514388 2016-12-01T18:04:51.88100 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:04:51.88102 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:04:51.90504 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:04:51.90509 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:04:51.90516 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:04:51.90522 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:04:51.90572 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:04:51.90573 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:04:51.90574 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:04:51.90574 0.03121747] 2016-12-01T18:04:51.90580 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:04:51.90585 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:04:51.90591 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:04:51.90597 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:04:51.90703 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:04:51.90770 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:04:51.90787 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:04:58.90972 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:04:58.93559 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6894230989 2016-12-01T18:04:58.93602 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6894230989 2016-12-01T18:04:58.99712 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:04:58.99727 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:04:59.03789 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:04:59.03791 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:04:59.03792 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:04:59.03793 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:04:59.03793 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:04:59.03794 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:04:59.03794 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:04:59.03796 0.03121747] 2016-12-01T18:04:59.03796 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:04:59.03797 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:04:59.03797 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:04:59.03798 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:04:59.04140 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:04:59.04562 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:04:59.04741 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:05:06.04645 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:05:06.05480 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.694583011 2016-12-01T18:05:06.05909 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.694583011 2016-12-01T18:05:06.11823 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:05:06.12264 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:05:06.15306 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:05:06.15308 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:05:06.15308 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:05:06.15309 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:05:06.15309 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:05:06.15310 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:05:06.15310 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:05:06.15311 0.03121747] 2016-12-01T18:05:06.15311 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:05:06.15312 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:05:06.15312 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:05:06.15313 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:05:06.15382 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:05:06.15472 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:05:06.15487 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:05:13.15543 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:05:13.18515 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6922862183 2016-12-01T18:05:13.18591 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6922862183 2016-12-01T18:05:13.24930 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:05:13.24945 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:05:13.31356 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:05:13.31358 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:05:13.31358 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:05:13.31359 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:05:13.31359 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:05:13.31361 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:05:13.31362 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:05:13.31362 0.03121747] 2016-12-01T18:05:13.31363 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:05:13.31363 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:05:13.31364 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:05:13.31364 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:05:13.31364 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:05:13.31418 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:05:13.31470 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:05:20.31493 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:05:20.36619 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6956282373 2016-12-01T18:05:20.36929 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6956282373 2016-12-01T18:05:20.42670 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:05:20.42672 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:05:20.46740 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:05:20.46742 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:05:20.46743 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:05:20.46743 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:05:20.46784 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:05:20.46785 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:05:20.46786 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:05:20.46786 0.03121747] 2016-12-01T18:05:20.46798 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:05:20.46809 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:05:20.46820 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:05:20.46831 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:05:20.47522 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:05:20.48198 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:05:20.48237 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:05:27.48282 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:05:27.52886 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6998808004 2016-12-01T18:05:27.52940 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6998808004 2016-12-01T18:05:27.59290 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:05:27.59309 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:05:27.61821 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:05:27.61827 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:05:27.61834 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:05:27.61840 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:05:27.61897 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:05:27.61898 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:05:27.61899 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:05:27.61899 0.03121747] 2016-12-01T18:05:27.61902 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:05:27.61905 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:05:27.61914 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:05:27.61915 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:05:27.62012 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:05:27.62072 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:05:27.62118 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:05:34.62165 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:05:34.63813 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6942379551 2016-12-01T18:05:34.64027 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6942379551 2016-12-01T18:05:34.69966 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:05:34.69978 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:05:34.72148 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:05:34.72161 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:05:34.72172 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:05:34.72183 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:05:34.72280 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:05:34.72281 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:05:34.72281 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:05:34.72282 0.03121747] 2016-12-01T18:05:34.72293 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:05:34.72302 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:05:34.72313 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:05:34.72327 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:05:34.72432 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:05:34.72497 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:05:34.72550 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:05:41.72581 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:05:41.74322 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6876825662 2016-12-01T18:05:41.74626 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6876825662 2016-12-01T18:05:41.80594 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:05:41.80596 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:05:41.83546 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:05:41.83548 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:05:41.83549 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:05:41.83549 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:05:41.83549 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:05:41.83550 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:05:41.83551 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:05:41.83551 0.03121747] 2016-12-01T18:05:41.83551 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:05:41.83552 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:05:41.83552 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:05:41.83553 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:05:41.83856 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:05:41.84315 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:05:41.84348 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:05:48.84464 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:05:48.85439 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6882371868 2016-12-01T18:05:48.85855 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6882371868 2016-12-01T18:05:48.92576 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:05:48.92577 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:05:48.95495 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:05:48.95497 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:05:48.95498 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:05:48.95498 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:05:48.95499 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:05:48.95499 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:05:48.95500 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:05:48.95500 0.03121747] 2016-12-01T18:05:48.95501 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:05:48.95509 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:05:48.95543 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:05:48.95544 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:05:48.96514 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:05:48.96605 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:05:48.96636 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:05:55.96820 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:05:55.97759 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6876834234 2016-12-01T18:05:55.97824 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6876834234 2016-12-01T18:05:56.04400 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:05:56.04403 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:05:56.07735 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:05:56.07737 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:05:56.07738 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:05:56.07738 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:05:56.07738 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:05:56.07739 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:05:56.07739 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:05:56.07740 0.03121747] 2016-12-01T18:05:56.07740 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:05:56.07741 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:05:56.07741 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:05:56.07742 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:05:56.08184 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:05:56.08595 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:05:56.08624 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:06:03.08666 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:06:03.14534 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6862728847 2016-12-01T18:06:03.14912 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6862728847 2016-12-01T18:06:03.20904 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:06:03.20906 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:06:03.26663 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:06:03.26667 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:06:03.26667 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:06:03.26668 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:06:03.26668 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:06:03.26670 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:06:03.26671 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:06:03.26671 0.03121747] 2016-12-01T18:06:03.26672 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:06:03.26673 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:06:03.26673 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:06:03.26673 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:06:03.26960 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:06:03.27506 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:06:03.27559 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:06:10.27632 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:06:10.30219 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6884793362 2016-12-01T18:06:10.30338 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6884793362 2016-12-01T18:06:10.36621 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:06:10.36623 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:06:10.39756 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:06:10.39758 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:06:10.39759 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:06:10.39759 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:06:10.39760 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:06:10.39760 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:06:10.39760 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:06:10.39761 0.03121747] 2016-12-01T18:06:10.39761 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:06:10.39762 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:06:10.39762 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:06:10.39762 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:06:10.39978 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:06:10.40297 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:06:10.40329 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:06:17.40392 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:06:17.40811 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6849301258 2016-12-01T18:06:17.41539 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6849301258 2016-12-01T18:06:17.46735 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:06:17.46737 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:06:17.50418 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:06:17.50420 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:06:17.50421 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:06:17.50421 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:06:17.50422 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:06:17.50423 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:06:17.50423 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:06:17.50424 0.03121747] 2016-12-01T18:06:17.50424 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:06:17.50425 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:06:17.50425 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:06:17.50426 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:06:17.51823 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:06:17.52225 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:06:17.52276 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:06:24.52645 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:06:24.57854 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6898559039 2016-12-01T18:06:24.57931 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6898559039 2016-12-01T18:06:24.64186 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:06:24.64280 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:06:24.68269 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:06:24.68281 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:06:24.68292 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:06:24.68303 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:06:24.68400 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:06:24.68401 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:06:24.68401 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:06:24.68402 0.03121747] 2016-12-01T18:06:24.68413 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:06:24.68423 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:06:24.68434 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:06:24.68445 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:06:24.68715 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:06:24.69028 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:06:24.69160 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:06:31.69188 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:06:31.74155 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6929493505 2016-12-01T18:06:31.74394 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6929493505 2016-12-01T18:06:31.80292 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:06:31.80304 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:06:31.86618 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:06:31.86621 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:06:31.86621 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:06:31.86622 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:06:31.86622 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:06:31.86623 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:06:31.86623 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:06:31.86624 0.03121747] 2016-12-01T18:06:31.86624 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:06:31.86625 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:06:31.86625 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:06:31.86626 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:06:31.87248 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:06:31.87395 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:06:31.87443 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:06:38.87487 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:06:38.92283 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6922162689 2016-12-01T18:06:38.92341 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6922162689 2016-12-01T18:06:38.98576 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:06:38.98611 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:06:39.04149 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:06:39.04151 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:06:39.04152 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:06:39.04152 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:06:39.04153 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:06:39.04153 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:06:39.04154 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:06:39.04154 0.03121747] 2016-12-01T18:06:39.04155 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:06:39.04155 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:06:39.04156 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:06:39.04156 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:06:39.04935 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:06:39.05009 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:06:39.05040 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:06:46.05072 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:06:46.09601 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6942064734 2016-12-01T18:06:46.09652 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6942064734 2016-12-01T18:06:46.15795 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:06:46.15805 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:06:46.20144 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:06:46.20146 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:06:46.20147 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:06:46.20148 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:06:46.20236 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:06:46.20237 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:06:46.20238 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:06:46.20238 0.03121747] 2016-12-01T18:06:46.20239 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:06:46.20241 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:06:46.20268 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:06:46.20269 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:06:46.20812 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:06:46.21356 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:06:46.21447 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:06:53.21529 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:06:53.26048 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6929924154 2016-12-01T18:06:53.26500 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6929924154 2016-12-01T18:06:53.32292 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:06:53.32294 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:06:53.44223 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:06:53.44230 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:06:53.44239 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:06:53.44396 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:06:53.44397 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:06:53.44398 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:06:53.44398 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:06:53.44399 0.03121747] 2016-12-01T18:06:53.44399 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:06:53.44400 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:06:53.44400 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:06:53.44401 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:06:53.44616 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:06:53.45063 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:06:53.45109 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:07:00.45146 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:07:00.49085 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6890077655 2016-12-01T18:07:00.49523 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6890077655 2016-12-01T18:07:00.55385 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:07:00.55387 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:07:00.58324 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:07:00.58331 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:07:00.58341 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:07:00.58349 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:07:00.58408 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:07:00.58409 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:07:00.58412 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:07:00.58412 0.03121747] 2016-12-01T18:07:00.58417 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:07:00.58427 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:07:00.58434 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:07:00.58441 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:07:00.58540 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:07:00.58601 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:07:00.58629 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:07:07.58681 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:07:07.62114 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6856922237 2016-12-01T18:07:07.62168 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6856922237 2016-12-01T18:07:07.68428 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:07:07.68430 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:07:07.73965 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:07:07.74089 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:07:07.74090 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:07:07.74091 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:07:07.74091 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:07:07.74092 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:07:07.74092 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:07:07.74093 0.03121747] 2016-12-01T18:07:07.74232 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:07:07.74234 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:07:07.74234 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:07:07.74235 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:07:07.74394 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:07:07.76836 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:07:07.77271 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:07:14.77308 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:07:14.79356 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6837633313 2016-12-01T18:07:14.79486 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6837633313 2016-12-01T18:07:14.85255 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:07:14.85257 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:07:15.07851 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:07:15.07853 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:07:15.07854 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:07:15.07854 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:07:15.07856 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:07:15.07856 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:07:15.07857 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:07:15.07857 0.03121747] 2016-12-01T18:07:15.07857 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:07:15.07858 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:07:15.07858 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:07:15.07859 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:07:15.07975 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:07:15.08039 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:07:15.08070 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:07:22.08107 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:07:22.13525 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6863496945 2016-12-01T18:07:22.13953 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6863496945 2016-12-01T18:07:22.19813 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:07:22.19829 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:07:22.24057 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:07:22.24069 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:07:22.24081 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:07:22.24094 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:07:22.24179 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:07:22.24180 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:07:22.24181 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:07:22.24181 0.03121747] 2016-12-01T18:07:22.24194 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:07:22.24204 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:07:22.24216 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:07:22.24228 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:07:22.24371 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:07:22.24451 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:07:22.24483 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:07:29.24665 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:07:29.29320 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6858872099 2016-12-01T18:07:29.29385 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6858872099 2016-12-01T18:07:29.35571 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:07:29.35583 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:07:29.38809 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:07:29.38812 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:07:29.38812 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:07:29.38813 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:07:29.38813 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:07:29.38814 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:07:29.38814 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:07:29.38815 0.03121747] 2016-12-01T18:07:29.38815 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:07:29.38816 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:07:29.38816 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:07:29.38817 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:07:29.39162 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:07:29.39350 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:07:29.39402 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:07:36.39437 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:07:36.39676 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6876270307 2016-12-01T18:07:36.39865 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6876270307 2016-12-01T18:07:36.46038 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:07:36.46041 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:07:36.48758 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:07:36.48760 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:07:36.48874 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:07:36.48885 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:07:36.48940 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:07:36.48941 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:07:36.48942 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:07:36.48942 0.03121747] 2016-12-01T18:07:36.48948 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:07:36.48953 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:07:36.48960 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:07:36.48967 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:07:36.49520 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:07:36.49588 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:07:36.50016 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:07:43.49786 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:07:43.50606 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6864246011 2016-12-01T18:07:43.51011 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6864246011 2016-12-01T18:07:43.56503 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:07:43.56512 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:07:43.60996 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:07:43.61000 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:07:43.61007 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:07:43.61012 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:07:43.61092 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:07:43.61093 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:07:43.61094 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:07:43.61094 0.03121747] 2016-12-01T18:07:43.61132 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:07:43.61133 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:07:43.61134 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:07:43.61134 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:07:43.61312 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:07:43.61393 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:07:43.61413 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:07:50.61436 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:07:50.61916 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6867703253 2016-12-01T18:07:50.62388 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6867703253 2016-12-01T18:07:50.67964 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:07:50.67966 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:07:50.70975 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:07:50.70980 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:07:50.70991 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:07:50.70996 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:07:50.71080 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:07:50.71080 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:07:50.71081 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:07:50.71081 0.03121747] 2016-12-01T18:07:50.71125 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:07:50.71126 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:07:50.71127 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:07:50.71127 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:07:50.71272 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:07:50.71331 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:07:50.71363 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:07:57.71401 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:07:57.72879 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6958126108 2016-12-01T18:07:57.73198 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6958126108 2016-12-01T18:07:57.79587 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:07:57.80093 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:07:57.83017 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:07:57.83019 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:07:57.83019 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:07:57.83020 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:07:57.83068 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:07:57.83069 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:07:57.83069 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:07:57.83070 0.03121747] 2016-12-01T18:07:57.83077 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:07:57.83084 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:07:57.83095 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:07:57.83101 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:07:57.83390 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:07:57.84208 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:07:57.84246 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:08:04.84439 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:08:04.89107 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.691950957 2016-12-01T18:08:04.89259 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.691950957 2016-12-01T18:08:04.95454 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:08:04.95469 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:08:04.98149 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:08:04.98160 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:08:04.98171 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:08:04.98180 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:08:04.98265 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:08:04.98266 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:08:04.98266 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:08:04.98267 0.03121747] 2016-12-01T18:08:04.98278 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:08:04.98287 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:08:04.98298 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:08:04.98307 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:08:04.98463 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:08:04.98579 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:08:04.98675 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:08:11.98632 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:08:11.99950 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6928014255 2016-12-01T18:08:12.00046 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6928014255 2016-12-01T18:08:12.06280 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:08:12.06293 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:08:12.09135 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:08:12.09137 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:08:12.09137 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:08:12.09138 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:08:12.09235 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:08:12.09236 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:08:12.09237 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:08:12.09238 0.03121747] 2016-12-01T18:08:12.09238 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:08:12.09239 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:08:12.09240 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:08:12.09255 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:08:12.09352 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:08:12.09404 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:08:12.09436 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:08:19.09509 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:08:19.09891 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6898723666 2016-12-01T18:08:19.10397 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6898723666 2016-12-01T18:08:19.16221 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:08:19.16223 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:08:19.19001 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:08:19.19003 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:08:19.19004 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:08:19.19004 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:08:19.19005 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:08:19.19005 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:08:19.19006 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:08:19.19006 0.03121747] 2016-12-01T18:08:19.19007 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:08:19.19007 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:08:19.19008 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:08:19.19008 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:08:19.19569 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:08:19.19647 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:08:19.19682 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:08:26.19762 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:08:26.22499 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6975521817 2016-12-01T18:08:26.22787 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6975521817 2016-12-01T18:08:26.28746 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:08:26.28748 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:08:26.32280 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:08:26.32283 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:08:26.32283 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:08:26.32284 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:08:26.32366 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:08:26.32368 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:08:26.32368 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:08:26.32369 0.03121747] 2016-12-01T18:08:26.32369 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:08:26.32370 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:08:26.32370 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:08:26.32371 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:08:26.32668 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:08:26.33027 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:08:26.33074 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:08:33.33106 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:08:33.34350 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6914353016 2016-12-01T18:08:33.34407 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6914353016 2016-12-01T18:08:33.40620 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:08:33.40635 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:08:33.46296 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:08:33.46298 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:08:33.46299 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:08:33.46299 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:08:33.46300 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:08:33.46300 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:08:33.46300 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:08:33.46301 0.03121747] 2016-12-01T18:08:33.46301 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:08:33.46302 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:08:33.46302 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:08:33.46304 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:08:33.46459 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:08:33.46524 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:08:33.46606 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:08:40.46636 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:08:40.51219 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6877818771 2016-12-01T18:08:40.51524 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6877818771 2016-12-01T18:08:40.57580 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:08:40.57582 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:08:40.61606 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:08:40.61609 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:08:40.61615 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:08:40.61616 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:08:40.61616 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:08:40.61617 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:08:40.61617 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:08:40.61618 0.03121747] 2016-12-01T18:08:40.61618 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:08:40.61619 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:08:40.61619 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:08:40.61620 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:08:40.61674 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:08:40.61739 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:08:40.61775 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:08:47.61816 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:08:47.62165 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.692159638 2016-12-01T18:08:47.62495 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.692159638 2016-12-01T18:08:47.68465 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:08:47.68468 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:08:47.71275 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:08:47.71283 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:08:47.71404 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:08:47.71405 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:08:47.71406 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:08:47.71406 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:08:47.71407 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:08:47.71409 0.03121747] 2016-12-01T18:08:47.71409 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:08:47.71410 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:08:47.71411 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:08:47.71411 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:08:47.71915 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:08:47.72008 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:08:47.72266 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:08:54.72301 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:08:54.74133 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6894850849 2016-12-01T18:08:54.74334 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6894850849 2016-12-01T18:08:54.80462 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:08:54.80464 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:08:54.83664 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:08:54.83666 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:08:54.83667 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:08:54.83667 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:08:54.83668 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:08:54.83668 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:08:54.83669 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:08:54.83669 0.03121747] 2016-12-01T18:08:54.83670 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:08:54.83670 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:08:54.83670 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:08:54.83671 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:08:54.83801 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:08:54.83855 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:08:54.83882 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:09:01.83908 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:09:01.84696 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6841112126 2016-12-01T18:09:01.85352 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6841112126 2016-12-01T18:09:01.91231 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:09:01.91233 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:09:01.94277 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:09:01.94279 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:09:01.94279 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:09:01.94280 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:09:01.94280 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:09:01.94282 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:09:01.94283 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:09:01.94283 0.03121747] 2016-12-01T18:09:01.94284 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:09:01.94284 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:09:01.94285 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:09:01.94285 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:09:01.95084 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:09:01.95359 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:09:01.95391 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:09:08.95419 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:09:08.96173 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6932793561 2016-12-01T18:09:08.96282 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6932793561 2016-12-01T18:09:09.02427 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:09:09.02429 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:09:09.06014 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:09:09.06016 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:09:09.06017 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:09:09.06017 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:09:09.06273 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:09:09.06274 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:09:09.06274 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:09:09.06275 0.03121747] 2016-12-01T18:09:09.06275 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:09:09.06276 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:09:09.06276 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:09:09.06277 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:09:09.06682 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:09:09.06859 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:09:09.06958 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:09:16.06984 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:09:16.08224 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6922702834 2016-12-01T18:09:16.08265 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6922702834 2016-12-01T18:09:16.14777 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:09:16.14779 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:09:16.17581 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:09:16.17587 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:09:16.17595 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:09:16.17601 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:09:16.17686 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:09:16.17687 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:09:16.17687 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:09:16.17688 0.03121747] 2016-12-01T18:09:16.17729 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:09:16.17730 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:09:16.17730 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:09:16.17731 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:09:16.17933 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:09:16.17994 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:09:16.18037 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:09:23.18089 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:09:23.18803 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6942421235 2016-12-01T18:09:23.18877 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6942421235 2016-12-01T18:09:23.24937 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:09:23.24939 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:09:23.34963 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:09:23.34965 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:09:23.34965 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:09:23.34966 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:09:23.34966 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:09:23.34967 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:09:23.34967 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:09:23.34968 0.03121747] 2016-12-01T18:09:23.34968 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:09:23.34969 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:09:23.34969 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:09:23.34970 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:09:23.35479 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:09:23.35558 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:09:23.35589 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:09:30.35604 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:09:30.41360 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6915096702 2016-12-01T18:09:30.41477 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6915096702 2016-12-01T18:09:30.47596 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:09:30.47612 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:09:30.50224 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:09:30.50236 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:09:30.50249 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:09:30.50258 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:09:30.50340 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:09:30.50341 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:09:30.50342 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:09:30.50342 0.03121747] 2016-12-01T18:09:30.50353 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:09:30.50365 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:09:30.50377 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:09:30.50389 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:09:30.50518 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:09:30.50583 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:09:30.50924 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:09:37.50627 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:09:37.54463 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.698329872 2016-12-01T18:09:37.54897 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.698329872 2016-12-01T18:09:37.60690 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:09:37.60692 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:09:37.64378 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:09:37.64380 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:09:37.64381 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:09:37.64381 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:09:37.64382 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:09:37.64382 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:09:37.64383 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:09:37.64383 0.03121747] 2016-12-01T18:09:37.64384 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:09:37.64422 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:09:37.64423 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:09:37.64424 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:09:37.65336 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:09:37.65667 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:09:37.65692 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:09:44.65812 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:09:44.65982 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6953201762 2016-12-01T18:09:44.66184 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6953201762 2016-12-01T18:09:44.72227 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:09:44.72231 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:09:44.75664 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:09:44.75666 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:09:44.75667 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:09:44.75667 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:09:44.75668 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:09:44.75668 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:09:44.75669 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:09:44.75669 0.03121747] 2016-12-01T18:09:44.75670 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:09:44.75670 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:09:44.75671 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:09:44.75671 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:09:44.76366 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:09:44.76499 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:09:44.76549 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:09:51.76583 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:09:51.76992 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6878277811 2016-12-01T18:09:51.77994 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6878277811 2016-12-01T18:09:51.83126 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:09:51.83128 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:09:51.86581 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:09:51.86583 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:09:51.86736 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:09:51.86737 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:09:51.86738 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:09:51.86739 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:09:51.86739 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:09:51.86740 0.03121747] 2016-12-01T18:09:51.86740 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:09:51.86741 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:09:51.86742 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:09:51.86742 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:09:51.87630 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:09:51.87759 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:09:51.88023 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:09:58.88451 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:09:58.93624 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6923170451 2016-12-01T18:09:58.93839 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6923170451 2016-12-01T18:09:59.00284 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:09:59.00286 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:09:59.04260 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:09:59.04262 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:09:59.04263 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:09:59.04264 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:09:59.04264 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:09:59.04265 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:09:59.04265 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:09:59.04266 0.03121747] 2016-12-01T18:09:59.04266 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:09:59.04267 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:09:59.04267 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:09:59.04267 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:09:59.05428 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:09:59.05603 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:09:59.05797 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:10:06.05915 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:10:06.09167 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.692824789 2016-12-01T18:10:06.09837 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.692824789 2016-12-01T18:10:06.15719 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:10:06.15721 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:10:06.17850 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:10:06.17853 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:10:06.17853 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:10:06.17854 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:10:06.17988 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:10:06.17989 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:10:06.17990 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:10:06.17990 0.03121747] 2016-12-01T18:10:06.17991 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:10:06.17991 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:10:06.17992 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:10:06.17992 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:10:06.18951 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:10:06.19018 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:10:06.19084 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:10:13.19133 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:10:13.23148 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6891044124 2016-12-01T18:10:13.23732 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6891044124 2016-12-01T18:10:13.30350 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:10:13.30353 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:10:13.37386 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:10:13.37398 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:10:13.37410 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:10:13.37421 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:10:13.37523 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:10:13.37524 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:10:13.37525 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:10:13.37525 0.03121747] 2016-12-01T18:10:13.37537 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:10:13.37546 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:10:13.37557 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:10:13.37568 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:10:13.39012 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:10:13.39361 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:10:13.39936 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:10:20.39815 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:10:20.42278 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.682094725 2016-12-01T18:10:20.42280 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.682094725 2016-12-01T18:10:20.48538 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:10:20.48540 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:10:20.50812 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:10:20.50818 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:10:20.50825 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:10:20.50831 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:10:20.50884 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:10:20.50901 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:10:20.50902 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:10:20.50903 0.03121747] 2016-12-01T18:10:20.50904 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:10:20.50904 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:10:20.50905 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:10:20.50924 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:10:20.51083 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:10:20.51336 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:10:20.51379 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:10:27.51501 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:10:27.54722 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6854427741 2016-12-01T18:10:27.54829 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6854427741 2016-12-01T18:10:27.61119 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:10:27.61122 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:10:27.64341 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:10:27.64345 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:10:27.64346 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:10:27.64346 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:10:27.64347 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:10:27.64347 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:10:27.64349 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:10:27.64350 0.03121747] 2016-12-01T18:10:27.64350 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:10:27.64351 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:10:27.64351 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:10:27.64352 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:10:27.64779 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:10:27.65184 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:10:27.65225 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:10:34.65259 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:10:34.66042 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6841711461 2016-12-01T18:10:34.66323 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6841711461 2016-12-01T18:10:34.72211 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:10:34.72230 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:10:34.75321 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:10:34.75333 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:10:34.75344 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:10:34.75354 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:10:34.75420 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:10:34.75421 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:10:34.75421 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:10:34.75422 0.03121747] 2016-12-01T18:10:34.75429 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:10:34.75435 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:10:34.75442 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:10:34.75448 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:10:34.76332 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:10:34.76400 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:10:34.76431 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:10:41.76646 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:10:41.78043 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6857532187 2016-12-01T18:10:41.78307 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6857532187 2016-12-01T18:10:41.83696 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:10:41.83699 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:10:41.86379 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:10:41.86381 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:10:41.86382 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:10:41.86383 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:10:41.86452 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:10:41.86453 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:10:41.86454 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:10:41.86454 0.03121747] 2016-12-01T18:10:41.86462 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:10:41.86470 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:10:41.86479 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:10:41.86487 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:10:41.86597 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:10:41.87731 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:10:41.87778 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:10:48.87836 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:10:48.88526 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6866191935 2016-12-01T18:10:48.89018 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6866191935 2016-12-01T18:10:48.94777 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:10:48.94789 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:10:48.98550 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:10:48.98552 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:10:48.98553 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:10:48.98554 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:10:48.98554 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:10:48.98555 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:10:48.98558 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:10:48.98558 0.03121747] 2016-12-01T18:10:48.98559 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:10:48.98559 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:10:48.98560 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:10:48.98560 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:10:48.98864 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:10:48.99135 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:10:48.99170 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:10:55.99203 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:10:55.99554 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6816068629 2016-12-01T18:10:55.99706 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6816068629 2016-12-01T18:10:56.05798 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:10:56.05817 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:10:56.08473 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:10:56.08475 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:10:56.08475 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:10:56.08476 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:10:56.08476 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:10:56.08477 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:10:56.08477 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:10:56.08478 0.03121747] 2016-12-01T18:10:56.08478 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:10:56.08479 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:10:56.08479 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:10:56.08480 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:10:56.08837 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:10:56.08889 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:10:56.08909 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:11:03.08968 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:11:03.10909 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6917922026 2016-12-01T18:11:03.10974 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6917922026 2016-12-01T18:11:03.17331 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:11:03.17346 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:11:03.20122 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:11:03.20124 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:11:03.20124 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:11:03.20125 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:11:03.20204 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:11:03.20205 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:11:03.20206 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:11:03.20206 0.03121747] 2016-12-01T18:11:03.20218 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:11:03.20227 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:11:03.20237 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:11:03.20244 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:11:03.20773 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:11:03.22095 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:11:03.22128 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:11:10.22450 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:11:10.22452 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6903734096 2016-12-01T18:11:10.22471 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6903734096 2016-12-01T18:11:10.28030 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:11:10.28032 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:11:10.31424 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:11:10.31426 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:11:10.31428 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:11:10.31584 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:11:10.31586 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:11:10.31586 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:11:10.31587 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:11:10.31587 0.03121747] 2016-12-01T18:11:10.31588 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:11:10.31588 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:11:10.31589 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:11:10.31589 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:11:10.31857 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:11:10.31920 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:11:10.31970 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:11:17.32062 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:11:17.33182 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6883555721 2016-12-01T18:11:17.33547 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6883555721 2016-12-01T18:11:17.39084 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:11:17.39086 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:11:17.41708 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:11:17.41721 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:11:17.41733 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:11:17.41744 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:11:17.41818 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:11:17.41819 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:11:17.41820 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:11:17.41820 0.03121747] 2016-12-01T18:11:17.41831 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:11:17.41841 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:11:17.41852 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:11:17.41862 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:11:17.42578 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:11:17.42812 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:11:17.42969 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:11:24.43186 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:11:24.44326 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6877386265 2016-12-01T18:11:24.44464 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6877386265 2016-12-01T18:11:24.50632 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:11:24.50634 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:11:24.53132 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:11:24.53141 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:11:24.53150 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:11:24.53159 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:11:24.53328 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:11:24.53330 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:11:24.53330 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:11:24.53331 0.03121747] 2016-12-01T18:11:24.53331 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:11:24.53332 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:11:24.53332 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:11:24.53333 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:11:24.53533 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:11:24.53599 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:11:24.53637 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:11:31.53685 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:11:31.55568 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6865445419 2016-12-01T18:11:31.55610 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6865445419 2016-12-01T18:11:31.61845 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:11:31.61854 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:11:31.67333 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:11:31.67334 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:11:31.67334 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:11:31.67335 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:11:31.67335 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:11:31.67336 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:11:31.67336 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:11:31.67337 0.03121747] 2016-12-01T18:11:31.67337 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:11:31.67338 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:11:31.67339 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:11:31.67339 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:11:31.67990 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:11:31.68024 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:11:31.68057 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:11:38.68110 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:11:38.74236 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6849713302 2016-12-01T18:11:38.74361 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6849713302 2016-12-01T18:11:38.80583 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:11:38.80592 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:11:38.84006 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:11:38.84008 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:11:38.84162 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:11:38.84163 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:11:38.84164 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:11:38.84165 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:11:38.84165 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:11:38.84166 0.03121747] 2016-12-01T18:11:38.84166 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:11:38.84167 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:11:38.84167 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:11:38.84168 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:11:38.84273 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:11:38.84346 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:11:38.84453 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:11:45.84442 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:11:45.86030 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6850679315 2016-12-01T18:11:45.86158 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6850679315 2016-12-01T18:11:45.92778 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:11:45.92782 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:11:45.95883 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:11:45.95885 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:11:45.95886 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:11:45.95887 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:11:45.95887 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:11:45.95887 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:11:45.95888 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:11:45.95888 0.03121747] 2016-12-01T18:11:45.95889 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:11:45.95891 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:11:45.95891 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:11:45.95892 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:11:45.95967 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:11:45.96168 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:11:45.96187 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:11:52.96265 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:11:52.96834 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6896644254 2016-12-01T18:11:52.97239 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6896644254 2016-12-01T18:11:53.02791 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:11:53.02793 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:11:53.48519 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:11:53.48521 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:11:53.48522 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:11:53.48523 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:11:53.48523 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:11:53.48524 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:11:53.48524 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:11:53.48524 0.03121747] 2016-12-01T18:11:53.48525 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:11:53.48525 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:11:53.48526 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:11:53.48526 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:11:53.49224 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:11:53.49292 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:11:53.49525 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:12:00.49808 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:12:00.53523 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6866196946 2016-12-01T18:12:00.53989 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6866196946 2016-12-01T18:12:00.59654 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:12:00.59660 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:12:00.62983 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:12:00.62986 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:12:00.62987 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:12:00.63133 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:12:00.63134 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:12:00.63135 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:12:00.63135 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:12:00.63136 0.03121747] 2016-12-01T18:12:00.63136 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:12:00.63136 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:12:00.63137 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:12:00.63137 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:12:00.64661 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:12:00.65480 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:12:00.65538 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:12:07.65573 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:12:07.71374 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6849024241 2016-12-01T18:12:07.71785 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6849024241 2016-12-01T18:12:07.77882 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:12:07.77884 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:12:07.81605 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:12:07.81607 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:12:07.81607 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:12:07.81608 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:12:07.81608 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:12:07.81609 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:12:07.81610 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:12:07.81610 0.03121747] 2016-12-01T18:12:07.81610 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:12:07.81611 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:12:07.81611 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:12:07.81612 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:12:07.81742 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:12:07.81808 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:12:07.81839 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:12:14.81891 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:12:14.83374 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6833450044 2016-12-01T18:12:14.83634 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6833450044 2016-12-01T18:12:14.90006 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:12:14.90008 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:12:14.93133 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:12:14.93141 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:12:14.93151 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:12:14.93160 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:12:14.93255 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:12:14.93256 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:12:14.93257 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:12:14.93257 0.03121747] 2016-12-01T18:12:14.93265 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:12:14.93271 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:12:14.93280 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:12:14.93287 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:12:14.93771 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:12:14.94284 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:12:14.94315 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:12:21.94352 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:12:22.00608 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6832896201 2016-12-01T18:12:22.01088 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6832896201 2016-12-01T18:12:22.06639 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:12:22.06641 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:12:22.10521 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:12:22.10523 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:12:22.10524 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:12:22.10524 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:12:22.10525 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:12:22.10526 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:12:22.10526 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:12:22.10527 0.03121747] 2016-12-01T18:12:22.10527 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:12:22.10528 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:12:22.10528 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:12:22.10530 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:12:22.11619 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:12:22.12016 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:12:22.12169 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:12:29.12382 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:12:29.12404 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6863880023 2016-12-01T18:12:29.12572 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6863880023 2016-12-01T18:12:29.18734 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:12:29.18736 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:12:29.22051 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:12:29.22062 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:12:29.22075 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:12:29.22086 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:12:29.22179 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:12:29.22180 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:12:29.22180 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:12:29.22181 0.03121747] 2016-12-01T18:12:29.22192 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:12:29.22202 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:12:29.22213 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:12:29.22224 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:12:29.23344 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:12:29.23412 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:12:29.23442 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:12:36.23489 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:12:36.28434 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6848650206 2016-12-01T18:12:36.28484 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6848650206 2016-12-01T18:12:36.34847 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:12:36.34858 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:12:36.42566 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:12:36.42577 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:12:36.42588 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:12:36.42598 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:12:36.42688 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:12:36.42689 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:12:36.42689 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:12:36.42691 0.03121747] 2016-12-01T18:12:36.42703 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:12:36.42712 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:12:36.42723 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:12:36.42732 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:12:36.42852 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:12:36.42998 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:12:36.43020 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:12:43.43089 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:12:43.45460 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6854582419 2016-12-01T18:12:43.45517 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6854582419 2016-12-01T18:12:43.51706 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:12:43.51717 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:12:43.65490 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:12:43.65496 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:12:43.65504 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:12:43.65510 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:12:43.65877 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:12:43.65878 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:12:43.65879 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:12:43.65879 0.03121747] 2016-12-01T18:12:43.65880 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:12:43.65880 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:12:43.65881 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:12:43.65881 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:12:43.67300 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:12:43.67948 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:12:43.67973 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:12:50.68012 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:12:50.69313 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6912576538 2016-12-01T18:12:50.69645 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6912576538 2016-12-01T18:12:50.76560 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:12:50.76562 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:12:50.80722 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:12:50.80724 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:12:50.80725 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:12:50.80725 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:12:50.80726 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:12:50.80728 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:12:50.80728 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:12:50.80729 0.03121747] 2016-12-01T18:12:50.80729 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:12:50.80730 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:12:50.80730 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:12:50.80730 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:12:50.81832 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:12:50.82582 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:12:50.82692 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:12:57.82624 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:12:57.86354 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6888811971 2016-12-01T18:12:57.86744 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6888811971 2016-12-01T18:12:57.92965 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:12:57.92967 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:12:58.16534 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:12:58.16536 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:12:58.16536 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:12:58.16537 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:12:58.16537 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:12:58.16538 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:12:58.16538 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:12:58.16539 0.03121747] 2016-12-01T18:12:58.16540 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:12:58.16549 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:12:58.16972 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:12:58.16974 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:12:58.17547 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:12:58.17935 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:12:58.18061 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:13:05.18153 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:13:05.22900 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6839446664 2016-12-01T18:13:05.22963 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6839446664 2016-12-01T18:13:05.29254 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:13:05.29256 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:13:05.32039 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:13:05.32042 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:13:05.32043 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:13:05.32044 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:13:05.32044 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:13:05.32045 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:13:05.32045 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:13:05.32046 0.03121747] 2016-12-01T18:13:05.32046 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:13:05.32047 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:13:05.32047 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:13:05.32048 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:13:05.32795 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:13:05.32847 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:13:05.32878 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:13:12.32892 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:13:12.34332 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6791298114 2016-12-01T18:13:12.34398 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6791298114 2016-12-01T18:13:12.40616 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:13:12.40619 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:13:12.43253 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:13:12.43255 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:13:12.43256 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:13:12.43256 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:13:12.43257 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:13:12.43257 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:13:12.43258 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:13:12.43258 0.03121747] 2016-12-01T18:13:12.43259 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:13:12.43260 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:13:12.43286 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:13:12.43287 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:13:12.43421 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:13:12.43483 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:13:12.43512 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:13:19.43583 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:13:19.44933 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6875891089 2016-12-01T18:13:19.45434 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6875891089 2016-12-01T18:13:19.51781 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:13:19.51783 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:13:19.55153 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:13:19.55155 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:13:19.55156 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:13:19.55156 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:13:19.55157 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:13:19.55157 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:13:19.55158 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:13:19.55158 0.03121747] 2016-12-01T18:13:19.55159 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:13:19.55159 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:13:19.55160 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:13:19.55160 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:13:19.55320 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:13:19.55380 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:13:19.55412 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:13:26.55430 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:13:26.61484 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.685879376 2016-12-01T18:13:26.61537 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.685879376 2016-12-01T18:13:26.67856 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:13:26.67876 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:13:26.70463 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:13:26.70468 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:13:26.70475 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:13:26.70482 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:13:26.70531 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:13:26.70532 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:13:26.70533 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:13:26.70533 0.03121747] 2016-12-01T18:13:26.70545 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:13:26.70547 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:13:26.70553 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:13:26.70556 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:13:26.70635 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:13:26.70851 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:13:26.70876 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:13:33.70906 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:13:33.71961 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.684044409 2016-12-01T18:13:33.72011 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.684044409 2016-12-01T18:13:33.78431 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:13:33.78452 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:13:33.81122 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:13:33.81133 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:13:33.81145 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:13:33.81156 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:13:33.81247 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:13:33.81248 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:13:33.81248 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:13:33.81249 0.03121747] 2016-12-01T18:13:33.81260 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:13:33.81269 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:13:33.81279 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:13:33.81289 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:13:33.81428 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:13:33.81490 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:13:33.81516 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:13:40.81534 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:13:40.81965 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6866278281 2016-12-01T18:13:40.82010 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6866278281 2016-12-01T18:13:40.88316 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:13:40.88330 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:13:40.91946 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:13:40.91957 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:13:40.91968 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:13:40.91978 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:13:40.92062 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:13:40.92063 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:13:40.92064 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:13:40.92064 0.03121747] 2016-12-01T18:13:40.92076 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:13:40.92085 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:13:40.92095 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:13:40.92105 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:13:40.92442 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:13:40.92497 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:13:40.92526 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:13:47.92624 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:13:47.98793 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6875510387 2016-12-01T18:13:47.99010 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6875510387 2016-12-01T18:13:48.05801 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:13:48.05816 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:13:48.10233 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:13:48.10327 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:13:48.10328 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:13:48.10328 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:13:48.10329 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:13:48.10329 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:13:48.10330 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:13:48.10330 0.03121747] 2016-12-01T18:13:48.10330 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:13:48.10331 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:13:48.10331 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:13:48.10332 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:13:48.10678 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:13:48.10748 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:13:48.10779 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:13:55.10857 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:13:55.16858 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6880668964 2016-12-01T18:13:55.17157 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6880668964 2016-12-01T18:13:55.23175 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:13:55.23178 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:13:55.26323 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:13:55.26325 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:13:55.26325 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:13:55.26326 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:13:55.26451 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:13:55.26453 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:13:55.26453 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:13:55.26454 0.03121747] 2016-12-01T18:13:55.26454 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:13:55.26455 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:13:55.26455 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:13:55.26455 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:13:55.26682 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:13:55.26746 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:13:55.26871 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:14:02.26928 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:14:02.27552 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6871155499 2016-12-01T18:14:02.27616 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6871155499 2016-12-01T18:14:02.33800 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:14:02.33802 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:14:02.36478 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:14:02.36480 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:14:02.36481 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:14:02.36482 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:14:02.36570 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:14:02.36571 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:14:02.36571 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:14:02.36572 0.03121747] 2016-12-01T18:14:02.36572 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:14:02.36573 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:14:02.36573 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:14:02.36574 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:14:02.37042 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:14:02.37110 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:14:02.37146 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:14:09.37172 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:14:09.37690 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6849968328 2016-12-01T18:14:09.38145 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6849968328 2016-12-01T18:14:09.43776 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:14:09.43793 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:14:09.46776 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:14:09.46788 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:14:09.46801 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:14:09.46812 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:14:09.46908 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:14:09.46909 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:14:09.46909 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:14:09.46910 0.03121747] 2016-12-01T18:14:09.46922 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:14:09.46932 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:14:09.46946 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:14:09.46950 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:14:09.47057 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:14:09.47196 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:14:09.47226 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:14:16.47271 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:14:16.49022 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6886230997 2016-12-01T18:14:16.49157 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6886230997 2016-12-01T18:14:16.55214 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:14:16.55216 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:14:16.57564 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:14:16.57566 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:14:16.57567 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:14:16.57567 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:14:16.57568 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:14:16.57569 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:14:16.57569 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:14:16.57570 0.03121747] 2016-12-01T18:14:16.57570 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:14:16.57570 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:14:16.57571 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:14:16.57571 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:14:16.58100 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:14:16.58583 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:14:16.58619 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:14:23.58639 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:14:23.61258 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6840055502 2016-12-01T18:14:23.61662 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6840055502 2016-12-01T18:14:23.67428 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:14:23.67437 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:14:23.77107 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:14:23.77118 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:14:23.77129 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:14:23.77140 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:14:23.77230 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:14:23.77231 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:14:23.77231 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:14:23.77232 0.03121747] 2016-12-01T18:14:23.77242 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:14:23.77246 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:14:23.77253 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:14:23.77261 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:14:23.77948 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:14:23.78010 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:14:23.78036 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:14:30.78220 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:14:30.78741 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6909361429 2016-12-01T18:14:30.79124 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6909361429 2016-12-01T18:14:30.85118 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:14:30.85122 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:14:30.88091 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:14:30.88093 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:14:30.88094 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:14:30.88094 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:14:30.88095 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:14:30.88095 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:14:30.88096 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:14:30.88096 0.03121747] 2016-12-01T18:14:30.88097 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:14:30.88097 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:14:30.88098 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:14:30.88098 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:14:30.89142 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:14:30.89891 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:14:30.90005 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:14:37.90185 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:14:37.95876 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6899792978 2016-12-01T18:14:37.96374 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6899792978 2016-12-01T18:14:38.02398 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:14:38.02401 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:14:38.05562 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:14:38.05569 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:14:38.05578 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:14:38.05587 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:14:38.05680 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:14:38.05681 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:14:38.05684 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:14:38.05684 0.03121747] 2016-12-01T18:14:38.05690 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:14:38.05697 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:14:38.05705 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:14:38.05713 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:14:38.07393 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:14:38.07470 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:14:38.07537 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:14:45.07616 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:14:45.13698 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6918024787 2016-12-01T18:14:45.13857 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6918024787 2016-12-01T18:14:45.19647 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:14:45.19668 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:14:45.22621 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:14:45.22633 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:14:45.22644 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:14:45.22655 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:14:45.22757 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:14:45.22758 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:14:45.22758 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:14:45.22759 0.03121747] 2016-12-01T18:14:45.22770 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:14:45.22781 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:14:45.22794 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:14:45.22805 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:14:45.23733 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:14:45.24074 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:14:45.24247 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:14:52.24540 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:14:52.29880 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6880437901 2016-12-01T18:14:52.30211 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6880437901 2016-12-01T18:14:52.36461 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:14:52.36464 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:14:52.39076 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:14:52.39084 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:14:52.39094 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:14:52.39102 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:14:52.39205 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:14:52.39206 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:14:52.39206 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:14:52.39207 0.03121747] 2016-12-01T18:14:52.39210 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:14:52.39217 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:14:52.39224 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:14:52.39232 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:14:52.40224 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:14:52.41167 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:14:52.41241 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:14:59.41515 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:14:59.47474 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6892186188 2016-12-01T18:14:59.47551 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6892186188 2016-12-01T18:14:59.53822 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:14:59.53845 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:14:59.57550 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:14:59.57552 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:14:59.57553 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:14:59.57553 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:14:59.57554 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:14:59.57554 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:14:59.57555 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:14:59.57555 0.03121747] 2016-12-01T18:14:59.57556 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:14:59.57556 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:14:59.57557 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:14:59.57557 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:14:59.57707 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:14:59.57771 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:14:59.57818 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:15:06.57844 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:15:06.59452 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.683827805 2016-12-01T18:15:06.59636 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.683827805 2016-12-01T18:15:06.65621 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:15:06.65622 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:15:06.68233 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:15:06.68239 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:15:06.68248 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:15:06.68269 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:15:06.68315 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:15:06.68316 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:15:06.68317 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:15:06.68317 0.03121747] 2016-12-01T18:15:06.68329 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:15:06.68362 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:15:06.68363 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:15:06.68363 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:15:06.68523 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:15:06.68603 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:15:06.68633 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:15:13.68682 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:15:13.69370 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6842133244 2016-12-01T18:15:13.69423 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6842133244 2016-12-01T18:15:13.76147 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:15:13.76149 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:15:13.81030 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:15:13.81033 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:15:13.81033 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:15:13.81034 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:15:13.81034 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:15:13.81035 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:15:13.81036 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:15:13.81036 0.03121747] 2016-12-01T18:15:13.81037 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:15:13.81037 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:15:13.81038 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:15:13.81038 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:15:13.81671 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:15:13.82111 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:15:13.82132 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:15:20.82174 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:15:20.87157 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6847996232 2016-12-01T18:15:20.87349 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6847996232 2016-12-01T18:15:20.93498 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:15:20.93500 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:15:20.97715 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:15:20.97717 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:15:20.97718 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:15:20.97718 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:15:20.97719 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:15:20.97719 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:15:20.97720 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:15:20.97720 0.03121747] 2016-12-01T18:15:20.97721 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:15:20.97721 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:15:20.97722 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:15:20.97722 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:15:20.97817 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:15:20.97887 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:15:20.97929 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:15:27.97945 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:15:27.98012 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.682758434 2016-12-01T18:15:27.98076 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.682758434 2016-12-01T18:15:28.04497 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:15:28.04511 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:15:28.07082 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:15:28.07084 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:15:28.07085 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:15:28.07085 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:15:28.07086 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:15:28.07086 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:15:28.07087 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:15:28.07087 0.03121747] 2016-12-01T18:15:28.07087 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:15:28.07088 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:15:28.07088 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:15:28.07089 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:15:28.07178 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:15:28.07242 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:15:28.07259 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:15:35.07278 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:15:35.08425 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6890142695 2016-12-01T18:15:35.08493 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6890142695 2016-12-01T18:15:35.14714 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:15:35.14719 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:15:35.17848 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:15:35.17862 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:15:35.17875 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:15:35.17887 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:15:35.17991 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:15:35.17992 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:15:35.17992 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:15:35.17993 0.03121747] 2016-12-01T18:15:35.18005 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:15:35.18015 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:15:35.18027 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:15:35.18039 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:15:35.18362 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:15:35.18422 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:15:35.18456 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:15:42.18487 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:15:42.19768 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6831515449 2016-12-01T18:15:42.19825 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6831515449 2016-12-01T18:15:42.26151 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:15:42.26182 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:15:42.29207 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:15:42.29209 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:15:42.29209 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:15:42.29210 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:15:42.29210 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:15:42.29210 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:15:42.29211 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:15:42.29211 0.03121747] 2016-12-01T18:15:42.29211 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:15:42.29212 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:15:42.29212 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:15:42.29212 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:15:42.29736 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:15:42.30174 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:15:42.30208 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:15:49.30264 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:15:49.32141 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6895942705 2016-12-01T18:15:49.32214 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6895942705 2016-12-01T18:15:49.38236 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:15:49.38238 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:15:49.44669 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:15:49.44671 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:15:49.44672 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:15:49.44673 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:15:49.44673 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:15:49.44674 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:15:49.44674 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:15:49.44675 0.03121747] 2016-12-01T18:15:49.44675 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:15:49.44676 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:15:49.44676 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:15:49.44676 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:15:49.45226 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:15:49.45686 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:15:49.45718 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:15:56.45745 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:15:56.48218 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6900371602 2016-12-01T18:15:56.48275 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6900371602 2016-12-01T18:15:56.54569 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:15:56.54571 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:15:56.58304 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:15:56.58306 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:15:56.58306 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:15:56.58307 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:15:56.58307 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:15:56.58307 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:15:56.58308 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:15:56.58308 0.03121747] 2016-12-01T18:15:56.58308 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:15:56.58309 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:15:56.58309 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:15:56.58309 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:15:56.58473 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:15:56.58524 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:15:56.58547 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:16:03.58559 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:16:03.64742 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6942819729 2016-12-01T18:16:03.64998 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6942819729 2016-12-01T18:16:03.70846 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:16:03.70857 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:16:03.74281 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:16:03.74283 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:16:03.74284 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:16:03.74284 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:16:03.74284 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:16:03.74285 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:16:03.74285 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:16:03.74286 0.03121747] 2016-12-01T18:16:03.74286 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:16:03.74287 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:16:03.74287 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:16:03.74287 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:16:03.74557 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:16:03.74883 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:16:03.75442 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:16:10.75349 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:16:10.75352 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6965011761 2016-12-01T18:16:10.75442 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6965011761 2016-12-01T18:16:10.81501 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:16:10.81503 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:16:10.84948 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:16:10.84950 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:16:10.84951 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:16:10.84952 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:16:10.84952 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:16:10.84953 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:16:10.84953 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:16:10.84954 0.03121747] 2016-12-01T18:16:10.84954 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:16:10.84955 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:16:10.84955 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:16:10.84957 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:16:10.85893 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:16:10.86778 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:16:10.86829 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:16:17.87037 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:16:17.93037 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6892889495 2016-12-01T18:16:17.93154 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6892889495 2016-12-01T18:16:17.99553 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:16:17.99555 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:16:18.03030 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:16:18.03037 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:16:18.03185 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:16:18.03186 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:16:18.03187 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:16:18.03187 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:16:18.03188 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:16:18.03188 0.03121747] 2016-12-01T18:16:18.03189 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:16:18.03189 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:16:18.03189 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:16:18.03190 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:16:18.03353 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:16:18.03428 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:16:18.03439 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:16:25.03463 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:16:25.03635 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6943250963 2016-12-01T18:16:25.03879 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6943250963 2016-12-01T18:16:25.09848 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:16:25.09850 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:16:25.13802 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:16:25.13804 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:16:25.13805 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:16:25.13805 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:16:25.13806 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:16:25.13806 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:16:25.13807 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:16:25.13809 0.03121747] 2016-12-01T18:16:25.13809 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:16:25.13810 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:16:25.13810 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:16:25.13811 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:16:25.15245 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:16:25.15540 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:16:25.15572 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:16:32.15605 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:16:32.21122 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6937604916 2016-12-01T18:16:32.21422 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6937604916 2016-12-01T18:16:32.27890 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:16:32.27892 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:16:32.30533 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:16:32.30535 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:16:32.30535 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:16:32.30536 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:16:32.30656 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:16:32.30657 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:16:32.30657 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:16:32.30658 0.03121747] 2016-12-01T18:16:32.30658 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:16:32.30659 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:16:32.30659 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:16:32.30660 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:16:32.30819 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:16:32.30870 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:16:32.30920 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:16:39.30995 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:16:39.32946 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6906084292 2016-12-01T18:16:39.33008 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6906084292 2016-12-01T18:16:39.39336 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:16:39.39337 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:16:39.42523 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:16:39.42525 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:16:39.42526 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:16:39.42526 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:16:39.42560 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:16:39.42562 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:16:39.42563 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:16:39.42563 0.03121747] 2016-12-01T18:16:39.42602 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:16:39.42603 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:16:39.42604 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:16:39.42604 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:16:39.42909 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:16:39.43163 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:16:39.43528 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:16:46.43722 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:16:46.45054 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6929506697 2016-12-01T18:16:46.45355 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6929506697 2016-12-01T18:16:46.51216 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:16:46.51218 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:16:46.54771 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:16:46.54773 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:16:46.54774 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:16:46.54774 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:16:46.54774 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:16:46.54775 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:16:46.54775 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:16:46.54776 0.03121747] 2016-12-01T18:16:46.54776 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:16:46.54777 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:16:46.54777 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:16:46.54778 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:16:46.55274 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:16:46.56058 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:16:46.56090 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:16:53.56113 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:16:53.61720 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6873326521 2016-12-01T18:16:53.61772 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6873326521 2016-12-01T18:16:53.67966 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:16:53.67968 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:16:53.74776 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:16:53.74783 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:16:53.74790 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:16:53.74797 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:16:53.74858 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:16:53.74859 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:16:53.74859 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:16:53.74860 0.03121747] 2016-12-01T18:16:53.74865 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:16:53.74870 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:16:53.74876 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:16:53.74882 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:16:53.75181 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:16:53.75410 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:16:53.75538 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:17:00.75491 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:17:00.77728 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6878655627 2016-12-01T18:17:00.78199 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6878655627 2016-12-01T18:17:00.83979 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:17:00.83991 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:17:00.86955 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:17:00.86957 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:17:00.86958 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:17:00.86958 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:17:00.87024 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:17:00.87025 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:17:00.87026 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:17:00.87026 0.03121747] 2016-12-01T18:17:00.87027 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:17:00.87027 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:17:00.87028 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:17:00.87028 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:17:00.87361 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:17:00.88311 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:17:00.88408 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:17:07.88483 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:17:07.88775 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6901066074 2016-12-01T18:17:07.89263 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6901066074 2016-12-01T18:17:07.94938 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:17:07.94949 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:17:08.43561 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:17:08.43564 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:17:08.43564 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:17:08.43565 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:17:08.43565 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:17:08.43566 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:17:08.43566 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:17:08.43567 0.03121747] 2016-12-01T18:17:08.43567 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:17:08.43568 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:17:08.43568 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:17:08.43569 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:17:08.43678 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:17:08.43746 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:17:08.43777 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:17:15.43796 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:17:15.49934 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6926449481 2016-12-01T18:17:15.50202 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6926449481 2016-12-01T18:17:15.56092 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:17:15.56107 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:17:15.59751 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:17:15.59753 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:17:15.59753 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:17:15.59754 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:17:15.59762 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:17:15.59763 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:17:15.59764 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:17:15.59764 0.03121747] 2016-12-01T18:17:15.59775 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:17:15.59784 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:17:15.59794 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:17:15.59804 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:17:15.60444 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:17:15.61324 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:17:15.61326 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:17:22.61277 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:17:22.67688 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6888952257 2016-12-01T18:17:22.67719 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6888952257 2016-12-01T18:17:22.73884 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:17:22.73886 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:17:22.77443 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:17:22.77445 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:17:22.77445 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:17:22.77446 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:17:22.77446 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:17:22.77447 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:17:22.77447 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:17:22.77448 0.03121747] 2016-12-01T18:17:22.77448 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:17:22.77448 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:17:22.77449 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:17:22.77449 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:17:22.78010 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:17:22.78666 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:17:22.78703 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:17:29.78746 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:17:29.78840 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6878067541 2016-12-01T18:17:29.78896 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6878067541 2016-12-01T18:17:29.85218 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:17:29.85245 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:17:29.89327 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:17:29.89328 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:17:29.89329 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:17:29.89329 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:17:29.89330 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:17:29.89330 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:17:29.89330 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:17:29.89331 0.03121747] 2016-12-01T18:17:29.89331 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:17:29.89331 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:17:29.89331 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:17:29.89332 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:17:29.90153 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:17:29.90991 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:17:29.91036 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:17:36.91466 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:17:36.91597 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6912382567 2016-12-01T18:17:36.91681 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6912382567 2016-12-01T18:17:36.97625 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:17:36.97627 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:17:37.01140 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:17:37.01142 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:17:37.01142 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:17:37.01143 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:17:37.01143 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:17:37.01144 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:17:37.01144 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:17:37.01145 0.03121747] 2016-12-01T18:17:37.01145 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:17:37.01146 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:17:37.01146 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:17:37.01147 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:17:37.01473 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:17:37.01954 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:17:37.02005 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:17:44.02426 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:17:44.07794 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6953023502 2016-12-01T18:17:44.08086 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6953023502 2016-12-01T18:17:44.14178 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:17:44.14180 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:17:44.17928 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:17:44.17936 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:17:44.17945 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:17:44.17954 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:17:44.18094 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:17:44.18095 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:17:44.18096 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:17:44.18097 0.03121747] 2016-12-01T18:17:44.18097 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:17:44.18098 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:17:44.18098 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:17:44.18099 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:17:44.18198 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:17:44.18273 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:17:44.18507 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:17:51.18357 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:17:51.18799 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6871503754 2016-12-01T18:17:51.18886 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6871503754 2016-12-01T18:17:51.25065 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:17:51.25067 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:17:51.28578 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:17:51.28581 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:17:51.28582 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:17:51.28582 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:17:51.28583 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:17:51.28584 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:17:51.28586 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:17:51.28587 0.03121747] 2016-12-01T18:17:51.28587 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:17:51.28587 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:17:51.28588 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:17:51.28588 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:17:51.28693 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:17:51.28809 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:17:51.28947 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:17:58.29183 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:17:58.29582 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6887561741 2016-12-01T18:17:58.29771 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6887561741 2016-12-01T18:17:58.36045 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:17:58.36048 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:17:58.40955 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:17:58.40957 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:17:58.40958 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:17:58.40958 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:17:58.40963 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:17:58.40964 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:17:58.40965 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:17:58.40965 0.03121747] 2016-12-01T18:17:58.40977 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:17:58.40987 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:17:58.40998 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:17:58.41009 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:17:58.41356 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:17:58.42158 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:17:58.42197 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:18:05.42207 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:18:05.46735 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6850992178 2016-12-01T18:18:05.46874 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6850992178 2016-12-01T18:18:05.53049 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:18:05.53062 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:18:05.55608 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:18:05.55757 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:18:05.55758 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:18:05.55758 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:18:05.55759 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:18:05.55759 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:18:05.55760 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:18:05.55760 0.03121747] 2016-12-01T18:18:05.55761 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:18:05.55761 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:18:05.55762 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:18:05.55762 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:18:05.55863 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:18:05.55931 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:18:05.55960 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:18:12.55983 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:18:12.58215 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6874786744 2016-12-01T18:18:12.58592 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6874786744 2016-12-01T18:18:12.64595 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:18:12.64601 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:18:12.68085 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:18:12.68087 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:18:12.68549 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:18:12.68550 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:18:12.68551 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:18:12.68552 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:18:12.68552 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:18:12.68553 0.03121747] 2016-12-01T18:18:12.68553 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:18:12.68555 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:18:12.68556 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:18:12.68556 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:18:12.68667 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:18:12.68707 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:18:12.68758 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:18:19.69102 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:18:19.74441 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6836751584 2016-12-01T18:18:19.75031 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6836751584 2016-12-01T18:18:19.80737 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:18:19.80739 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:18:19.88086 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:18:19.88088 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:18:19.88216 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:18:19.88217 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:18:19.88217 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:18:19.88218 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:18:19.88218 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:18:19.88218 0.03121747] 2016-12-01T18:18:19.88219 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:18:19.88219 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:18:19.88220 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:18:19.88220 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:18:19.88386 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:18:19.88502 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:18:19.88540 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:18:26.88561 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:18:26.90541 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.685707262 2016-12-01T18:18:26.90598 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.685707262 2016-12-01T18:18:26.96607 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:18:26.96611 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:18:27.03143 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:18:27.03146 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:18:27.03147 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:18:27.03147 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:18:27.03148 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:18:27.03148 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:18:27.03150 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:18:27.03150 0.03121747] 2016-12-01T18:18:27.03151 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:18:27.03151 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:18:27.03152 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:18:27.03152 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:18:27.04155 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:18:27.04401 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:18:27.04425 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:18:34.04508 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:18:34.06775 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6811398537 2016-12-01T18:18:34.07027 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6811398537 2016-12-01T18:18:34.13369 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:18:34.13382 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:18:34.17051 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:18:34.17053 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:18:34.17054 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:18:34.17054 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:18:34.17055 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:18:34.17055 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:18:34.17056 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:18:34.17056 0.03121747] 2016-12-01T18:18:34.17057 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:18:34.17057 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:18:34.17057 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:18:34.17058 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:18:34.17945 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:18:34.18075 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:18:34.18107 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:18:41.18131 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:18:41.24539 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6929018269 2016-12-01T18:18:41.24609 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6929018269 2016-12-01T18:18:41.30734 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:18:41.30745 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:18:41.34019 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:18:41.34169 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:18:41.34170 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:18:41.34171 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:18:41.34172 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:18:41.34173 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:18:41.34173 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:18:41.34174 0.03121747] 2016-12-01T18:18:41.34174 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:18:41.34175 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:18:41.34175 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:18:41.34176 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:18:41.34303 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:18:41.34551 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:18:41.34578 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:18:48.34596 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:18:48.35312 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6911917441 2016-12-01T18:18:48.35731 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6911917441 2016-12-01T18:18:48.41531 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:18:48.41533 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:18:48.49134 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:18:48.49136 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:18:48.49136 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:18:48.49137 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:18:48.49354 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:18:48.49355 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:18:48.49355 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:18:48.49356 0.03121747] 2016-12-01T18:18:48.49356 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:18:48.49357 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:18:48.49357 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:18:48.49358 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:18:48.49902 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:18:48.50564 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:18:48.50598 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:18:55.50767 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:18:55.55481 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6922007712 2016-12-01T18:18:55.55654 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6922007712 2016-12-01T18:18:55.61854 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:18:55.61883 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:18:55.67269 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:18:55.67272 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:18:55.67273 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:18:55.67273 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:18:55.67274 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:18:55.67274 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:18:55.67275 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:18:55.67275 0.03121747] 2016-12-01T18:18:55.67276 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:18:55.67277 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:18:55.67305 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:18:55.67306 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:18:55.67700 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:18:55.67761 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:18:55.67788 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:19:02.67818 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:19:02.73416 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6853554688 2016-12-01T18:19:02.73477 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6853554688 2016-12-01T18:19:02.79076 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:19:02.79086 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:19:02.81504 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:19:02.81506 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:19:02.81507 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:19:02.81507 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:19:02.81525 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:19:02.81526 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:19:02.81527 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:19:02.81527 0.03121747] 2016-12-01T18:19:02.81534 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:19:02.81540 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:19:02.81552 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:19:02.81557 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:19:02.81670 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:19:02.81849 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:19:02.81883 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:19:09.81902 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:19:09.82668 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6906907841 2016-12-01T18:19:09.83082 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6906907841 2016-12-01T18:19:09.88932 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:19:09.89026 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:19:09.93922 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:19:09.93924 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:19:09.93924 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:19:09.93925 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:19:09.93925 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:19:09.93926 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:19:09.93926 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:19:09.93927 0.03121747] 2016-12-01T18:19:09.93927 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:19:09.93928 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:19:09.93928 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:19:09.93929 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:19:09.94740 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:19:09.95164 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:19:09.95212 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:19:16.95239 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:19:16.99488 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6896044477 2016-12-01T18:19:16.99559 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6896044477 2016-12-01T18:19:17.06391 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:19:17.06626 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:19:17.09680 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:19:17.09784 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:19:17.09785 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:19:17.09786 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:19:17.09786 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:19:17.09786 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:19:17.09787 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:19:17.09787 0.03121747] 2016-12-01T18:19:17.09787 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:19:17.09788 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:19:17.09788 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:19:17.09788 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:19:17.09946 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:19:17.10461 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:19:17.10494 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:19:24.10537 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:19:24.11520 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6846524862 2016-12-01T18:19:24.11663 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6846524862 2016-12-01T18:19:24.18115 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:19:24.18131 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:19:24.21255 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:19:24.21261 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:19:24.21268 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:19:24.21360 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:19:24.21360 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:19:24.21361 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:19:24.21362 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:19:24.21362 0.03121747] 2016-12-01T18:19:24.21362 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:19:24.21363 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:19:24.21363 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:19:24.21363 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:19:24.21619 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:19:24.21671 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:19:24.21705 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:19:31.21811 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:19:31.23015 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6827188168 2016-12-01T18:19:31.23065 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6827188168 2016-12-01T18:19:31.29398 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:19:31.29413 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:19:31.33471 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:19:31.33473 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:19:31.33473 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:19:31.33473 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:19:31.33473 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:19:31.33474 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:19:31.33474 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:19:31.33474 0.03121747] 2016-12-01T18:19:31.33475 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:19:31.33475 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:19:31.33476 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:19:31.33482 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:19:31.33599 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:19:31.33650 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:19:31.33686 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:19:38.33718 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:19:38.34263 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6780433099 2016-12-01T18:19:38.34305 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6780433099 2016-12-01T18:19:38.40671 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:19:38.40682 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:19:38.44216 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:19:38.44361 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:19:38.44362 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:19:38.44362 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:19:38.44362 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:19:38.44362 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:19:38.44363 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:19:38.44363 0.03121747] 2016-12-01T18:19:38.44363 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:19:38.44364 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:19:38.44364 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:19:38.44364 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:19:38.44427 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:19:38.44480 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:19:38.44506 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:19:45.44557 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:19:45.45524 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6775330988 2016-12-01T18:19:45.45731 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6775330988 2016-12-01T18:19:45.51892 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:19:45.51894 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:19:45.55100 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:19:45.55102 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:19:45.55102 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:19:45.55103 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:19:45.55103 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:19:45.55104 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:19:45.55104 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:19:45.55105 0.03121747] 2016-12-01T18:19:45.55105 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:19:45.55106 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:19:45.55106 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:19:45.55107 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:19:45.55215 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:19:45.55281 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:19:45.55311 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:19:52.55315 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:19:52.56619 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6784906636 2016-12-01T18:19:52.56696 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6784906636 2016-12-01T18:19:52.63004 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:19:52.63023 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:19:52.67664 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:19:52.67675 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:19:52.67686 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:19:52.67697 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:19:52.67764 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:19:52.67765 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:19:52.67766 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:19:52.67766 0.03121747] 2016-12-01T18:19:52.67770 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:19:52.67774 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:19:52.67780 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:19:52.67786 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:19:52.68306 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:19:52.68670 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:19:52.68697 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:19:59.68745 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:19:59.74609 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6781414063 2016-12-01T18:19:59.74718 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6781414063 2016-12-01T18:19:59.80845 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:19:59.81338 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:19:59.84947 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:19:59.84951 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:19:59.84951 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:19:59.84952 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:19:59.84953 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:19:59.84953 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:19:59.84955 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:19:59.84956 0.03121747] 2016-12-01T18:19:59.84956 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:19:59.84957 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:19:59.84957 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:19:59.84959 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:19:59.85366 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:19:59.85431 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:19:59.85693 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:20:06.85537 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:20:06.91844 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6810026387 2016-12-01T18:20:06.91938 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6810026387 2016-12-01T18:20:06.98335 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:20:06.98337 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:20:07.01311 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:20:07.01313 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:20:07.01314 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:20:07.01314 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:20:07.01315 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:20:07.01315 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:20:07.01316 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:20:07.01316 0.03121747] 2016-12-01T18:20:07.01317 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:20:07.01317 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:20:07.01318 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:20:07.01318 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:20:07.02807 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:20:07.02946 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:20:07.03048 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:20:14.03069 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:20:14.04461 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6824146815 2016-12-01T18:20:14.05415 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6824146815 2016-12-01T18:20:14.10865 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:20:14.10868 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:20:14.15175 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:20:14.15177 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:20:14.15177 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:20:14.15178 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:20:14.15178 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:20:14.15179 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:20:14.15179 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:20:14.15181 0.03121747] 2016-12-01T18:20:14.15182 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:20:14.15183 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:20:14.15183 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:20:14.15183 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:20:14.15262 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:20:14.15324 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:20:14.16488 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:20:21.15538 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:20:21.21352 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6835052922 2016-12-01T18:20:21.21548 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6835052922 2016-12-01T18:20:21.27871 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:20:21.27873 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:20:21.31028 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:20:21.31125 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:20:21.31126 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:20:21.31126 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:20:21.31127 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:20:21.31127 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:20:21.31128 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:20:21.31128 0.03121747] 2016-12-01T18:20:21.31129 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:20:21.31129 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:20:21.31136 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:20:21.31142 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:20:21.31226 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:20:21.31542 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:20:21.31643 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:20:28.31675 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:20:28.33459 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6795683652 2016-12-01T18:20:28.33937 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6795683652 2016-12-01T18:20:28.39153 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:20:28.39173 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:20:28.56866 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:20:28.56873 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:20:28.56880 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:20:28.56887 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:20:28.56940 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:20:28.56942 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:20:28.56943 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:20:28.56943 0.03121747] 2016-12-01T18:20:28.56948 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:20:28.56954 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:20:28.56960 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:20:28.56967 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:20:28.57086 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:20:28.57154 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:20:28.57205 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:20:35.57239 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:20:35.61232 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6883262908 2016-12-01T18:20:35.61306 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6883262908 2016-12-01T18:20:35.67588 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:20:35.67591 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:20:35.70611 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:20:35.70613 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:20:35.70613 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:20:35.70614 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:20:35.70619 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:20:35.70620 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:20:35.70621 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:20:35.70622 0.03121747] 2016-12-01T18:20:35.70634 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:20:35.70643 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:20:35.70654 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:20:35.70665 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:20:35.70768 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:20:35.71139 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:20:35.71171 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:20:42.71231 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:20:42.71560 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6863053493 2016-12-01T18:20:42.71638 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6863053493 2016-12-01T18:20:42.77991 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:20:42.78007 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:20:42.82328 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:20:42.82329 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:20:42.82331 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:20:42.82331 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:20:42.82355 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:20:42.82356 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:20:42.82356 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:20:42.82357 0.03121747] 2016-12-01T18:20:42.82369 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:20:42.82379 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:20:42.82390 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:20:42.82400 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:20:42.82672 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:20:42.82745 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:20:42.82928 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:20:49.82949 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:20:49.88017 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6821835057 2016-12-01T18:20:49.88586 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6821835057 2016-12-01T18:20:49.94419 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:20:49.94421 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:20:49.96389 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:20:49.96391 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:20:49.96392 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:20:49.96393 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:20:49.96530 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:20:49.96531 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:20:49.96532 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:20:49.96532 0.03121747] 2016-12-01T18:20:49.96533 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:20:49.96533 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:20:49.96534 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:20:49.96534 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:20:49.96627 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:20:49.96689 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:20:49.96711 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:20:56.97147 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:20:56.98349 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6864626442 2016-12-01T18:20:56.98411 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6864626442 2016-12-01T18:20:57.04748 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:20:57.04751 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:20:57.07523 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:20:57.07525 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:20:57.07526 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:20:57.07526 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:20:57.07527 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:20:57.07527 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:20:57.07528 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:20:57.07528 0.03121747] 2016-12-01T18:20:57.07529 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:20:57.07534 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:20:57.07546 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:20:57.07551 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:20:57.08026 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:20:57.08093 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:20:57.08355 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:21:04.08391 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:21:04.09290 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6840627409 2016-12-01T18:21:04.09366 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6840627409 2016-12-01T18:21:04.15776 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:21:04.15778 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:21:04.20002 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:21:04.20004 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:21:04.20005 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:21:04.20006 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:21:04.20069 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:21:04.20071 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:21:04.20071 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:21:04.20072 0.03121747] 2016-12-01T18:21:04.20072 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:21:04.20073 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:21:04.20073 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:21:04.20074 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:21:04.20168 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:21:04.20445 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:21:04.20607 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:21:11.20629 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:21:11.21177 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6836017888 2016-12-01T18:21:11.21512 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6836017888 2016-12-01T18:21:11.27267 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:21:11.27278 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:21:11.30383 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:21:11.30389 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:21:11.30396 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:21:11.30402 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:21:11.30465 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:21:11.30466 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:21:11.30466 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:21:11.30466 0.03121747] 2016-12-01T18:21:11.30472 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:21:11.30477 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:21:11.30483 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:21:11.30489 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:21:11.30581 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:21:11.30643 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:21:11.30668 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:21:18.30717 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:21:18.31469 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6844243241 2016-12-01T18:21:18.31581 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6844243241 2016-12-01T18:21:18.38036 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:21:18.38038 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:21:18.41021 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:21:18.41023 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:21:18.41024 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:21:18.41024 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:21:18.41096 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:21:18.41097 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:21:18.41097 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:21:18.41098 0.03121747] 2016-12-01T18:21:18.41112 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:21:18.41125 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:21:18.41137 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:21:18.41152 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:21:18.41258 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:21:18.41320 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:21:18.41364 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:21:25.41389 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:21:25.42635 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6857210665 2016-12-01T18:21:25.42682 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6857210665 2016-12-01T18:21:25.49103 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:21:25.49105 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:21:25.52099 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:21:25.52101 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:21:25.52102 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:21:25.52102 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:21:25.52103 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:21:25.52103 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:21:25.52104 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:21:25.52104 0.03121747] 2016-12-01T18:21:25.52105 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:21:25.52105 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:21:25.52106 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:21:25.52106 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:21:25.52460 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:21:25.52523 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:21:25.52563 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:21:32.52675 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:21:32.54613 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6900452187 2016-12-01T18:21:32.55340 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6900452187 2016-12-01T18:21:32.60494 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:21:32.60503 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:21:32.64172 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:21:32.64175 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:21:32.64175 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:21:32.64175 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:21:32.64270 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:21:32.64271 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:21:32.64272 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:21:32.64272 0.03121747] 2016-12-01T18:21:32.64272 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:21:32.64273 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:21:32.64273 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:21:32.64274 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:21:32.64922 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:21:32.65254 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:21:32.65299 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:21:39.65328 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:21:39.68133 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6832476401 2016-12-01T18:21:39.68365 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6832476401 2016-12-01T18:21:39.74317 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:21:39.74320 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:21:39.77790 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:21:39.77792 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:21:39.77793 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:21:39.77793 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:21:39.77794 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:21:39.77794 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:21:39.77795 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:21:39.77795 0.03121747] 2016-12-01T18:21:39.77796 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:21:39.77796 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:21:39.77797 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:21:39.77797 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:21:39.78442 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:21:39.78946 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:21:39.79020 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:21:46.79672 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:21:46.85407 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6854209133 2016-12-01T18:21:46.85508 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6854209133 2016-12-01T18:21:46.91705 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:21:46.91708 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:21:46.94798 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:21:46.94810 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:21:46.94822 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:21:46.94833 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:21:46.94929 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:21:46.94930 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:21:46.94931 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:21:46.94931 0.03121747] 2016-12-01T18:21:46.94942 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:21:46.94946 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:21:46.94960 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:21:46.94965 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:21:46.95074 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:21:46.95429 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:21:46.95460 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:21:53.95527 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:21:53.98635 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6817284189 2016-12-01T18:21:53.99214 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6817284189 2016-12-01T18:21:54.04846 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:21:54.04848 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:21:54.07523 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:21:54.07525 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:21:54.07535 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:21:54.07542 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:21:54.07656 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:21:54.07657 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:21:54.07658 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:21:54.07658 0.03121747] 2016-12-01T18:21:54.07659 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:21:54.07701 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:21:54.07702 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:21:54.07702 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:21:54.07842 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:21:54.07918 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:21:54.07971 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:22:01.08014 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:22:01.09622 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6898284031 2016-12-01T18:22:01.09702 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6898284031 2016-12-01T18:22:01.15969 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:22:01.15984 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:22:01.18215 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:22:01.18223 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:22:01.18232 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:22:01.18245 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:22:01.18341 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:22:01.18342 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:22:01.18343 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:22:01.18343 0.03121747] 2016-12-01T18:22:01.18351 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:22:01.18358 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:22:01.18367 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:22:01.18392 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:22:01.19134 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:22:01.19194 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:22:01.19222 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:22:08.19261 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:22:08.20935 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6848748856 2016-12-01T18:22:08.20967 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6848748856 2016-12-01T18:22:08.27301 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:22:08.27304 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:22:08.32526 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:22:08.32805 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:22:08.32807 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:22:08.32807 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:22:08.32808 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:22:08.32808 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:22:08.32809 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:22:08.32809 0.03121747] 2016-12-01T18:22:08.32810 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:22:08.32810 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:22:08.32811 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:22:08.32811 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:22:08.33152 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:22:08.33276 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:22:08.33328 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:22:15.33437 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:22:15.38608 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6887020237 2016-12-01T18:22:15.38874 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6887020237 2016-12-01T18:22:15.44975 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:22:15.45004 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:22:15.48099 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:22:15.48101 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:22:15.48102 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:22:15.48102 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:22:15.48103 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:22:15.48104 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:22:15.48105 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:22:15.48106 0.03121747] 2016-12-01T18:22:15.48106 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:22:15.48107 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:22:15.48107 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:22:15.48108 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:22:15.49540 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:22:15.50742 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:22:15.50938 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:22:22.51085 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:22:22.56162 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6842927085 2016-12-01T18:22:22.56430 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6842927085 2016-12-01T18:22:22.62475 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:22:22.62478 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:22:22.65074 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:22:22.65076 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:22:22.65077 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:22:22.65077 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:22:22.65078 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:22:22.65078 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:22:22.65079 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:22:22.65080 0.03121747] 2016-12-01T18:22:22.65080 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:22:22.65081 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:22:22.65081 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:22:22.65082 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:22:22.66218 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:22:22.67769 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:22:22.68054 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:22:29.68084 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:22:29.73823 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6927318918 2016-12-01T18:22:29.73911 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6927318918 2016-12-01T18:22:29.80119 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:22:29.80134 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:22:29.82982 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:22:29.82984 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:22:29.83107 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:22:29.83108 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:22:29.83110 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:22:29.83111 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:22:29.83111 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:22:29.83111 0.03121747] 2016-12-01T18:22:29.83112 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:22:29.83112 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:22:29.83113 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:22:29.83113 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:22:29.83266 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:22:29.83539 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:22:29.83638 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:22:36.83661 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:22:36.84396 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6899373758 2016-12-01T18:22:36.84451 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6899373758 2016-12-01T18:22:36.90708 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:22:36.90729 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:22:36.93773 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:22:36.93778 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:22:36.93786 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:22:36.93800 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:22:36.93885 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:22:36.93886 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:22:36.93886 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:22:36.93887 0.03121747] 2016-12-01T18:22:36.93898 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:22:36.93908 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:22:36.93918 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:22:36.93932 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:22:36.94336 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:22:36.94397 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:22:36.94426 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:22:43.94832 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:22:43.95693 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.688012605 2016-12-01T18:22:43.95761 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.688012605 2016-12-01T18:22:44.01985 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:22:44.02005 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:22:44.05107 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:22:44.05121 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:22:44.05133 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:22:44.05143 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:22:44.05237 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:22:44.05238 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:22:44.05239 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:22:44.05239 0.03121747] 2016-12-01T18:22:44.05251 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:22:44.05261 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:22:44.05272 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:22:44.05283 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:22:44.05425 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:22:44.05546 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:22:44.05758 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:22:51.05763 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:22:51.05820 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6839991472 2016-12-01T18:22:51.06357 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6839991472 2016-12-01T18:22:51.12273 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:22:51.12276 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:22:51.15253 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:22:51.15264 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:22:51.15276 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:22:51.15286 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:22:51.15376 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:22:51.15376 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:22:51.15377 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:22:51.15377 0.03121747] 2016-12-01T18:22:51.15390 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:22:51.15400 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:22:51.15411 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:22:51.15421 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:22:51.15518 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:22:51.15580 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:22:51.15610 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:22:58.15636 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:22:58.17233 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6856866305 2016-12-01T18:22:58.17288 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6856866305 2016-12-01T18:22:58.23433 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:22:58.23435 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:22:58.28956 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:22:58.28958 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:22:58.28959 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:22:58.28959 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:22:58.28960 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:22:58.28960 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:22:58.28961 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:22:58.28961 0.03121747] 2016-12-01T18:22:58.28962 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:22:58.28962 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:22:58.28963 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:22:58.28963 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:22:58.29088 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:22:58.29156 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:22:58.29181 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:23:05.29835 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:23:05.36622 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6937923583 2016-12-01T18:23:05.36759 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6937923583 2016-12-01T18:23:05.42131 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:23:05.42133 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:23:05.45958 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:23:05.45960 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:23:05.45960 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:23:05.45961 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:23:05.46040 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:23:05.46042 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:23:05.46042 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:23:05.46043 0.03121747] 2016-12-01T18:23:05.46043 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:23:05.46044 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:23:05.46044 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:23:05.46045 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:23:05.46151 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:23:05.46217 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:23:05.46233 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:23:12.46266 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:23:12.47515 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6863430589 2016-12-01T18:23:12.48007 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6863430589 2016-12-01T18:23:12.53768 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:23:12.53771 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:23:12.56502 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:23:12.56505 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:23:12.56505 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:23:12.56506 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:23:12.56577 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:23:12.56578 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:23:12.56579 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:23:12.56579 0.03121747] 2016-12-01T18:23:12.56587 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:23:12.56719 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:23:12.56722 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:23:12.56723 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:23:12.56988 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:23:12.57067 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:23:12.57190 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:23:19.57212 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:23:19.59281 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6880139732 2016-12-01T18:23:19.59597 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6880139732 2016-12-01T18:23:19.65564 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:23:19.65583 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:23:19.67887 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:23:19.67897 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:23:19.67909 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:23:19.67919 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:23:19.68005 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:23:19.68006 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:23:19.68006 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:23:19.68007 0.03121747] 2016-12-01T18:23:19.68017 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:23:19.68026 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:23:19.68036 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:23:19.68046 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:23:19.68627 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:23:19.68687 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:23:19.68869 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:23:26.68884 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:23:26.74898 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.694200849 2016-12-01T18:23:26.74960 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.694200849 2016-12-01T18:23:26.80824 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:23:26.80845 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:23:26.83213 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:23:26.83219 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:23:26.83228 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:23:26.83238 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:23:26.83334 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:23:26.83335 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:23:26.83336 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:23:26.83336 0.03121747] 2016-12-01T18:23:26.83348 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:23:26.83362 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:23:26.83371 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:23:26.83375 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:23:26.83630 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:23:26.83689 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:23:26.83717 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:23:33.83741 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:23:33.85727 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6888634845 2016-12-01T18:23:33.85778 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6888634845 2016-12-01T18:23:33.92042 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:23:33.92045 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:23:33.94613 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:23:33.94615 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:23:33.94616 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:23:33.94623 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:23:33.94709 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:23:33.94710 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:23:33.94711 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:23:33.94712 0.03121747] 2016-12-01T18:23:33.94725 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:23:33.94735 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:23:33.94745 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:23:33.94755 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:23:33.95126 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:23:33.95454 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:23:33.95750 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:23:40.96165 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:23:40.96656 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6883872066 2016-12-01T18:23:40.97266 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6883872066 2016-12-01T18:23:41.03037 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:23:41.03039 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:23:41.07222 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:23:41.07224 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:23:41.07225 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:23:41.07225 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:23:41.07226 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:23:41.07226 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:23:41.07227 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:23:41.07227 0.03121747] 2016-12-01T18:23:41.07228 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:23:41.07228 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:23:41.07229 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:23:41.07229 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:23:41.07852 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:23:41.08625 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:23:41.08966 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:23:48.09165 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:23:48.13522 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.687866233 2016-12-01T18:23:48.13893 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.687866233 2016-12-01T18:23:48.20074 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:23:48.20076 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:23:48.28683 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:23:48.28686 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:23:48.28686 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:23:48.28687 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:23:48.28747 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:23:48.28748 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:23:48.28749 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:23:48.28749 0.03121747] 2016-12-01T18:23:48.28750 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:23:48.28750 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:23:48.28751 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:23:48.28752 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:23:48.28839 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:23:48.29631 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:23:48.30032 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:23:55.30407 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:23:55.36062 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6857584487 2016-12-01T18:23:55.36065 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6857584487 2016-12-01T18:23:55.42338 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:23:55.42349 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:23:55.45133 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:23:55.45135 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:23:55.45136 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:23:55.45136 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:23:55.45136 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:23:55.45137 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:23:55.45137 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:23:55.45138 0.03121747] 2016-12-01T18:23:55.45138 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:23:55.45139 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:23:55.45139 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:23:55.45139 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:23:55.45569 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:23:55.45641 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:23:55.45670 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:24:02.45749 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:24:02.46600 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6789356338 2016-12-01T18:24:02.46670 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6789356338 2016-12-01T18:24:02.53201 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:24:02.53203 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:24:02.55802 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:24:02.55805 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:24:02.55805 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:24:02.55806 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:24:02.55806 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:24:02.55807 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:24:02.55807 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:24:02.55809 0.03121747] 2016-12-01T18:24:02.55809 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:24:02.55810 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:24:02.55810 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:24:02.55811 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:24:02.56228 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:24:02.56437 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:24:02.56468 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:24:09.56583 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:24:09.57864 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6802300655 2016-12-01T18:24:09.58049 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6802300655 2016-12-01T18:24:09.64591 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:24:09.64593 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:24:09.67795 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:24:09.67797 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:24:09.67797 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:24:09.67798 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:24:09.67798 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:24:09.67798 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:24:09.67799 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:24:09.67799 0.03121747] 2016-12-01T18:24:09.67800 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:24:09.67800 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:24:09.67801 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:24:09.67801 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:24:09.68251 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:24:09.69254 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:24:09.69499 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:24:16.69309 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:24:16.73773 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.679004543 2016-12-01T18:24:16.74089 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.679004543 2016-12-01T18:24:16.80094 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:24:16.80097 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:24:16.83415 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:24:16.83417 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:24:16.83418 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:24:16.83419 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:24:16.83419 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:24:16.83421 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:24:16.83422 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:24:16.83422 0.03121747] 2016-12-01T18:24:16.83423 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:24:16.83423 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:24:16.83424 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:24:16.83425 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:24:16.83551 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:24:16.83723 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:24:16.83762 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:24:23.83783 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:24:23.84807 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6790181752 2016-12-01T18:24:23.84963 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6790181752 2016-12-01T18:24:23.91115 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:24:23.91117 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:24:23.95761 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:24:23.95763 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:24:23.95764 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:24:23.95764 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:24:23.95765 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:24:23.95765 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:24:23.95766 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:24:23.95766 0.03121747] 2016-12-01T18:24:23.95767 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:24:23.95767 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:24:23.95768 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:24:23.95768 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:24:23.95876 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:24:23.95948 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:24:23.95973 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:24:30.96067 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:24:31.02036 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6836002077 2016-12-01T18:24:31.02725 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6836002077 2016-12-01T18:24:31.07724 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:24:31.07727 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:24:31.11553 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:24:31.11555 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:24:31.11557 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:24:31.11557 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:24:31.11558 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:24:31.11558 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:24:31.11559 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:24:31.11559 0.03121747] 2016-12-01T18:24:31.11560 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:24:31.11560 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:24:31.11560 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:24:31.11561 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:24:31.12380 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:24:31.13164 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:24:31.13205 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:24:38.13249 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:24:38.19152 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6809283477 2016-12-01T18:24:38.19495 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6809283477 2016-12-01T18:24:38.24906 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:24:38.24941 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:24:38.31631 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:24:38.31633 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:24:38.31633 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:24:38.31634 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:24:38.31634 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:24:38.31634 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:24:38.31635 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:24:38.31635 0.03121747] 2016-12-01T18:24:38.31635 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:24:38.31636 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:24:38.31636 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:24:38.31636 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:24:38.32514 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:24:38.33425 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:24:38.33449 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:24:45.33500 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:24:45.34698 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6836294847 2016-12-01T18:24:45.34965 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6836294847 2016-12-01T18:24:45.40927 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:24:45.40938 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:24:45.43654 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:24:45.43661 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:24:45.43668 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:24:45.43674 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:24:45.43724 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:24:45.43725 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:24:45.43725 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:24:45.43726 0.03121747] 2016-12-01T18:24:45.43731 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:24:45.43736 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:24:45.43742 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:24:45.43748 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:24:45.43925 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:24:45.43980 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:24:45.44099 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:24:52.44152 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:24:52.46473 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.690029237 2016-12-01T18:24:52.46750 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.690029237 2016-12-01T18:24:52.52566 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:24:52.52568 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:24:52.56264 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:24:52.56269 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:24:52.56327 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:24:52.56328 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:24:52.56360 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:24:52.56361 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:24:52.56361 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:24:52.56362 0.03121747] 2016-12-01T18:24:52.56369 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:24:52.56375 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:24:52.56384 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:24:52.56393 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:24:52.56516 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:24:52.56580 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:24:52.56678 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:24:59.56700 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:24:59.63158 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6823675902 2016-12-01T18:24:59.63292 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6823675902 2016-12-01T18:24:59.69226 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:24:59.69228 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:24:59.71801 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:24:59.71803 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:24:59.71803 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:24:59.71804 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:24:59.71804 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:24:59.71805 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:24:59.71805 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:24:59.71806 0.03121747] 2016-12-01T18:24:59.71806 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:24:59.71807 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:24:59.71807 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:24:59.71807 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:24:59.72046 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:24:59.72287 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:24:59.72311 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:25:06.72474 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:25:06.75904 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6883497395 2016-12-01T18:25:06.76246 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6883497395 2016-12-01T18:25:06.81686 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:25:06.81720 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:25:06.85407 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:25:06.85409 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:25:06.85410 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:25:06.85410 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:25:06.85411 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:25:06.85411 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:25:06.85412 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:25:06.85412 0.03121747] 2016-12-01T18:25:06.85413 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:25:06.85413 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:25:06.85414 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:25:06.85414 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:25:06.86352 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:25:06.87372 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:25:06.87429 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:25:13.87614 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:25:13.89285 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6846993534 2016-12-01T18:25:13.90043 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6846993534 2016-12-01T18:25:13.95434 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:25:13.95436 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:25:13.98763 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:25:13.98765 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:25:13.98766 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:25:13.98766 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:25:13.98767 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:25:13.98767 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:25:13.98768 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:25:13.98768 0.03121747] 2016-12-01T18:25:13.98769 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:25:13.98769 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:25:13.98770 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:25:13.98770 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:25:13.99450 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:25:13.99794 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:25:13.99830 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:25:21.00000 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:25:21.01755 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6932562059 2016-12-01T18:25:21.02881 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6932562059 2016-12-01T18:25:21.07701 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:25:21.07949 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:25:21.12222 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:25:21.12224 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:25:21.12225 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:25:21.12225 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:25:21.12225 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:25:21.12226 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:25:21.12226 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:25:21.12227 0.03121747] 2016-12-01T18:25:21.12227 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:25:21.12228 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:25:21.12228 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:25:21.12229 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:25:21.13310 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:25:21.13764 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:25:21.13924 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:25:28.14181 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:25:28.18708 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6810691458 2016-12-01T18:25:28.18710 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6810691458 2016-12-01T18:25:28.24762 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:25:28.25045 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:25:28.42508 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:25:28.42510 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:25:28.42510 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:25:28.42511 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:25:28.42511 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:25:28.42512 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:25:28.42513 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:25:28.42513 0.03121747] 2016-12-01T18:25:28.42513 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:25:28.42514 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:25:28.42515 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:25:28.42518 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:25:28.42641 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:25:28.42817 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:25:28.42852 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:25:35.42915 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:25:35.44026 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6835915733 2016-12-01T18:25:35.44428 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6835915733 2016-12-01T18:25:35.50317 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:25:35.50338 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:25:35.53132 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:25:35.53141 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:25:35.53152 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:25:35.53156 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:25:35.53208 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:25:35.53208 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:25:35.53209 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:25:35.53209 0.03121747] 2016-12-01T18:25:35.53210 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:25:35.53215 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:25:35.53219 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:25:35.53225 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:25:35.53318 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:25:35.53380 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:25:35.53409 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:25:42.53639 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:25:42.56558 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6900715748 2016-12-01T18:25:42.57018 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6900715748 2016-12-01T18:25:42.62887 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:25:42.62889 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:25:42.67710 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:25:42.67712 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:25:42.67713 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:25:42.67713 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:25:42.67714 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:25:42.67714 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:25:42.67715 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:25:42.67715 0.03121747] 2016-12-01T18:25:42.67716 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:25:42.67716 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:25:42.67717 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:25:42.67717 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:25:42.67909 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:25:42.68023 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:25:42.68301 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:25:49.68371 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:25:49.73784 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6855479315 2016-12-01T18:25:49.73866 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6855479315 2016-12-01T18:25:49.80053 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:25:49.80055 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:25:49.83743 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:25:49.83748 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:25:49.83754 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:25:49.83759 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:25:49.83876 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:25:49.83877 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:25:49.83878 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:25:49.83878 0.03121747] 2016-12-01T18:25:49.83878 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:25:49.83880 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:25:49.83881 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:25:49.83881 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:25:49.83976 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:25:49.84044 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:25:49.84076 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:25:56.84288 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:25:56.89940 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6815679968 2016-12-01T18:25:56.90114 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6815679968 2016-12-01T18:25:56.96144 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:25:56.96155 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:25:57.00864 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:25:57.00866 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:25:57.00951 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:25:57.00952 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:25:57.01001 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:25:57.01002 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:25:57.01003 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:25:57.01003 0.03121747] 2016-12-01T18:25:57.01004 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:25:57.01004 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:25:57.01005 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:25:57.01005 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:25:57.01621 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:25:57.01677 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:25:57.01708 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:26:04.01847 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:26:04.06418 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6841092426 2016-12-01T18:26:04.06545 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6841092426 2016-12-01T18:26:04.13488 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:26:04.13499 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:26:04.17145 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:26:04.17147 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:26:04.17148 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:26:04.17148 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:26:04.17206 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:26:04.17207 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:26:04.17209 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:26:04.17210 0.03121747] 2016-12-01T18:26:04.17223 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:26:04.17236 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:26:04.17248 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:26:04.17259 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:26:04.17708 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:26:04.17772 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:26:04.17802 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:26:11.17813 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:26:11.22528 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6890212773 2016-12-01T18:26:11.22564 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6890212773 2016-12-01T18:26:11.28864 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:26:11.28866 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:26:11.32153 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:26:11.32155 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:26:11.32156 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:26:11.32156 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:26:11.32156 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:26:11.32157 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:26:11.32157 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:26:11.32158 0.03121747] 2016-12-01T18:26:11.32158 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:26:11.32159 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:26:11.32159 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:26:11.32160 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:26:11.32460 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:26:11.32670 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:26:11.32704 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:26:18.32703 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:26:18.33697 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6862732906 2016-12-01T18:26:18.33764 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6862732906 2016-12-01T18:26:18.40122 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:26:18.40125 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:26:18.51522 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:26:18.51525 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:26:18.51525 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:26:18.51526 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:26:18.51527 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:26:18.51528 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:26:18.51529 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:26:18.51530 0.03121747] 2016-12-01T18:26:18.51530 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:26:18.51531 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:26:18.51531 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:26:18.51532 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:26:18.51648 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:26:18.52095 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:26:18.52139 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:26:25.52450 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:26:25.56459 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6878148484 2016-12-01T18:26:25.56612 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6878148484 2016-12-01T18:26:25.62786 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:26:25.62798 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:26:25.66258 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:26:25.66260 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:26:25.66260 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:26:25.66261 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:26:25.66600 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:26:25.66602 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:26:25.66602 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:26:25.66603 0.03121747] 2016-12-01T18:26:25.66603 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:26:25.66604 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:26:25.66604 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:26:25.66605 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:26:25.66852 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:26:25.67897 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:26:25.67948 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:26:32.67997 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:26:32.73787 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6889327886 2016-12-01T18:26:32.74195 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6889327886 2016-12-01T18:26:32.79991 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:26:32.80008 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:26:32.82927 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:26:32.82932 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:26:32.82932 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:26:32.82933 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:26:32.83063 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:26:32.83064 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:26:32.83064 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:26:32.83065 0.03121747] 2016-12-01T18:26:32.83065 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:26:32.83066 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:26:32.83066 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:26:32.83067 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:26:32.83227 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:26:32.83294 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:26:32.83518 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:26:39.83575 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:26:39.84660 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6878383852 2016-12-01T18:26:39.85026 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6878383852 2016-12-01T18:26:39.91236 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:26:39.91251 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:26:39.94706 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:26:39.94712 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:26:39.94723 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:26:39.94731 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:26:39.94816 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:26:39.94817 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:26:39.94817 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:26:39.94818 0.03121747] 2016-12-01T18:26:39.94829 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:26:39.94838 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:26:39.94848 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:26:39.94857 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:26:39.95610 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:26:39.95675 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:26:39.95704 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:26:46.95752 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:26:46.95803 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6850860152 2016-12-01T18:26:46.95932 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6850860152 2016-12-01T18:26:47.02114 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:26:47.02116 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:26:47.05311 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:26:47.05322 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:26:47.05330 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:26:47.05462 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:26:47.05463 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:26:47.05464 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:26:47.05464 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:26:47.05465 0.03121747] 2016-12-01T18:26:47.05465 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:26:47.05465 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:26:47.05466 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:26:47.05466 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:26:47.05771 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:26:47.06497 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:26:47.06527 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:26:54.06580 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:26:54.11463 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6838826084 2016-12-01T18:26:54.11993 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6838826084 2016-12-01T18:26:54.18252 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:26:54.18255 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:26:54.20769 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:26:54.20771 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:26:54.20772 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:26:54.20772 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:26:54.20861 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:26:54.20862 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:26:54.20862 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:26:54.20863 0.03121747] 2016-12-01T18:26:54.20875 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:26:54.20885 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:26:54.20896 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:26:54.20906 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:26:54.21486 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:26:54.21578 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:26:54.21626 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:27:01.21660 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:27:01.22815 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.688028397 2016-12-01T18:27:01.23172 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.688028397 2016-12-01T18:27:01.29228 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:27:01.29231 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:27:01.34338 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:27:01.34340 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:27:01.34341 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:27:01.34341 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:27:01.34342 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:27:01.34342 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:27:01.34343 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:27:01.34343 0.03121747] 2016-12-01T18:27:01.34344 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:27:01.34344 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:27:01.34344 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:27:01.34345 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:27:01.34682 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:27:01.34939 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:27:01.34965 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:27:08.35130 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:27:08.40104 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6869475856 2016-12-01T18:27:08.40335 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6869475856 2016-12-01T18:27:08.46390 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:27:08.46411 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:27:08.50504 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:27:08.50519 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:27:08.50533 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:27:08.50544 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:27:08.50654 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:27:08.50655 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:27:08.50656 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:27:08.50657 0.03121747] 2016-12-01T18:27:08.50670 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:27:08.50680 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:27:08.50692 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:27:08.50703 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:27:08.50957 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:27:08.51017 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:27:08.51067 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:27:15.51192 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:27:15.52430 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6876245641 2016-12-01T18:27:15.52936 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6876245641 2016-12-01T18:27:15.58774 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:27:15.58776 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:27:15.62769 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:27:15.62771 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:27:15.62772 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:27:15.62772 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:27:15.62772 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:27:15.62773 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:27:15.62774 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:27:15.62774 0.03121747] 2016-12-01T18:27:15.62774 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:27:15.62775 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:27:15.62775 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:27:15.62776 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:27:15.64089 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:27:15.65669 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:27:15.65702 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:27:22.65751 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:27:22.68714 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6803595596 2016-12-01T18:27:22.69045 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6803595596 2016-12-01T18:27:22.75247 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:27:22.75249 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:27:22.80700 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:27:22.80708 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:27:22.80718 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:27:22.80729 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:27:22.80826 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:27:22.80827 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:27:22.80828 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:27:22.80828 0.03121747] 2016-12-01T18:27:22.80917 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:27:22.80918 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:27:22.80918 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:27:22.80919 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:27:22.81178 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:27:22.81248 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:27:22.81642 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:27:29.81720 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:27:29.85010 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6839963865 2016-12-01T18:27:29.85275 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6839963865 2016-12-01T18:27:29.91423 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:27:29.91442 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:27:29.98927 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:27:29.98929 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:27:29.98930 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:27:29.98930 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:27:29.98931 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:27:29.98931 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:27:29.98931 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:27:29.98932 0.03121747] 2016-12-01T18:27:29.98932 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:27:29.98933 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:27:29.99019 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:27:29.99020 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:27:29.99618 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:27:29.99768 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:27:29.99814 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:27:36.99968 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:27:37.01426 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6786356416 2016-12-01T18:27:37.01488 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6786356416 2016-12-01T18:27:37.07683 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:27:37.07703 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:27:37.35532 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:27:37.35539 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:27:37.35549 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:27:37.35557 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:27:37.35650 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:27:37.35651 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:27:37.35652 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:27:37.35652 0.03121747] 2016-12-01T18:27:37.35659 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:27:37.35667 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:27:37.35675 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:27:37.35684 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:27:37.36062 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:27:37.36168 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:27:37.36216 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:27:44.36243 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:27:44.37722 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6774412586 2016-12-01T18:27:44.37940 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6774412586 2016-12-01T18:27:44.43850 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:27:44.43859 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:27:44.50640 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:27:44.50653 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:27:44.50666 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:27:44.50678 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:27:44.50779 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:27:44.50781 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:27:44.50782 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:27:44.50782 0.03121747] 2016-12-01T18:27:44.50794 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:27:44.50805 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:27:44.50817 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:27:44.50829 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:27:44.51839 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:27:44.52523 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:27:44.52705 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:27:51.52808 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:27:51.55918 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6734247151 2016-12-01T18:27:51.55977 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6734247151 2016-12-01T18:27:51.62087 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:27:51.62090 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:27:51.67511 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:27:51.67513 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:27:51.67514 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:27:51.67514 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:27:51.67602 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:27:51.67604 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:27:51.67604 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:27:51.67605 0.03121747] 2016-12-01T18:27:51.67607 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:27:51.67607 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:27:51.67608 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:27:51.67608 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:27:51.68007 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:27:51.68293 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:27:51.68307 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:27:58.68359 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:27:58.72679 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.679857309 2016-12-01T18:27:58.72844 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.679857309 2016-12-01T18:27:58.78758 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:27:58.78784 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:27:59.10405 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:27:59.10416 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:27:59.10427 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:27:59.10437 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:27:59.10528 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:27:59.10529 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:27:59.10529 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:27:59.10530 0.03121747] 2016-12-01T18:27:59.10541 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:27:59.10550 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:27:59.10560 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:27:59.10570 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:27:59.10757 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:27:59.11281 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:27:59.11325 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:28:06.11895 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:28:06.14760 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6867799442 2016-12-01T18:28:06.14898 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6867799442 2016-12-01T18:28:06.20412 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:28:06.20440 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:28:06.40685 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:28:06.40692 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:28:06.40853 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:28:06.40854 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:28:06.40854 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:28:06.40856 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:28:06.40857 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:28:06.40857 0.03121747] 2016-12-01T18:28:06.40858 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:28:06.40858 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:28:06.40859 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:28:06.40859 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:28:06.41444 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:28:06.41943 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:28:06.42721 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:28:13.42661 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:28:13.43778 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6840688092 2016-12-01T18:28:13.43860 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6840688092 2016-12-01T18:28:13.50313 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:28:13.50386 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:28:13.56523 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:28:13.56534 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:28:13.56543 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:28:13.56554 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:28:13.56701 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:28:13.56702 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:28:13.56702 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:28:13.56703 0.03121747] 2016-12-01T18:28:13.56703 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:28:13.56704 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:28:13.56704 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:28:13.56705 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:28:13.56891 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:28:13.56962 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:28:13.56989 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:28:20.57079 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:28:20.61648 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6880120883 2016-12-01T18:28:20.61719 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6880120883 2016-12-01T18:28:20.67927 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:28:20.67929 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:28:20.70992 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:28:20.70995 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:28:20.70997 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:28:20.70998 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:28:20.70998 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:28:20.70999 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:28:20.70999 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:28:20.71000 0.03121747] 2016-12-01T18:28:20.71001 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:28:20.71001 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:28:20.71002 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:28:20.71002 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:28:20.71314 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:28:20.71396 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:28:20.71426 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:28:27.71446 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:28:27.77138 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.679737224 2016-12-01T18:28:27.77178 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.679737224 2016-12-01T18:28:27.83559 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:28:27.83573 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:28:27.86128 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:28:27.86134 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:28:27.86141 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:28:27.86147 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:28:27.86201 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:28:27.86202 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:28:27.86203 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:28:27.86203 0.03121747] 2016-12-01T18:28:27.86209 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:28:27.86214 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:28:27.86220 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:28:27.86226 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:28:27.86784 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:28:27.87371 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:28:27.87373 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:28:34.87258 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:28:34.93249 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6825150744 2016-12-01T18:28:34.93400 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6825150744 2016-12-01T18:28:34.99767 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:28:34.99769 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:28:35.02484 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:28:35.02486 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:28:35.02486 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:28:35.02487 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:28:35.02487 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:28:35.02488 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:28:35.02488 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:28:35.02489 0.03121747] 2016-12-01T18:28:35.02489 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:28:35.02489 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:28:35.02490 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:28:35.02490 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:28:35.03448 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:28:35.03542 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:28:35.03554 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:28:42.03760 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:28:42.08689 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6868051086 2016-12-01T18:28:42.08736 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6868051086 2016-12-01T18:28:42.14983 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:28:42.15003 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:28:42.17939 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:28:42.17950 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:28:42.17961 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:28:42.17971 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:28:42.18061 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:28:42.18062 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:28:42.18062 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:28:42.18063 0.03121747] 2016-12-01T18:28:42.18075 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:28:42.18084 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:28:42.18094 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:28:42.18104 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:28:42.18372 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:28:42.18673 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:28:42.18735 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:28:49.18719 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:28:49.18972 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6796753898 2016-12-01T18:28:49.19364 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6796753898 2016-12-01T18:28:49.25354 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:28:49.25365 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:28:49.28763 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:28:49.28775 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:28:49.28788 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:28:49.28799 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:28:49.28898 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:28:49.28899 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:28:49.28899 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:28:49.28900 0.03121747] 2016-12-01T18:28:49.28912 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:28:49.28922 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:28:49.28933 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:28:49.28943 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:28:49.29046 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:28:49.29191 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:28:49.29224 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:28:56.29493 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:28:56.30223 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6840534884 2016-12-01T18:28:56.30553 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6840534884 2016-12-01T18:28:56.36447 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:28:56.36449 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:28:56.39329 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:28:56.39331 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:28:56.39332 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:28:56.39332 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:28:56.39333 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:28:56.39333 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:28:56.39334 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:28:56.39335 0.03121747] 2016-12-01T18:28:56.39335 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:28:56.39336 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:28:56.39336 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:28:56.39337 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:28:56.39781 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:28:56.39848 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:28:56.40139 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:29:03.40367 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:29:03.41475 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6824180327 2016-12-01T18:29:03.41987 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6824180327 2016-12-01T18:29:03.47753 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:29:03.47773 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:29:03.50467 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:29:03.50480 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:29:03.50493 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:29:03.50504 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:29:03.50599 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:29:03.50600 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:29:03.50601 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:29:03.50602 0.03121747] 2016-12-01T18:29:03.50614 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:29:03.50632 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:29:03.50650 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:29:03.50665 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:29:03.51601 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:29:03.52975 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:29:03.53023 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:29:10.53058 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:29:10.53363 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6806973966 2016-12-01T18:29:10.54236 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6806973966 2016-12-01T18:29:10.59250 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:29:10.59252 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:29:10.62384 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:29:10.62515 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:29:10.62516 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:29:10.62517 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:29:10.62517 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:29:10.62518 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:29:10.62519 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:29:10.62520 0.03121747] 2016-12-01T18:29:10.62520 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:29:10.62521 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:29:10.62521 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:29:10.62522 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:29:10.62791 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:29:10.62968 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:29:10.62992 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:29:17.63136 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:29:17.63774 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6838281452 2016-12-01T18:29:17.63840 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6838281452 2016-12-01T18:29:17.70139 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:29:17.70141 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:29:17.72770 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:29:17.72772 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:29:17.72773 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:29:17.72773 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:29:17.72774 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:29:17.72774 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:29:17.72775 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:29:17.72775 0.03121747] 2016-12-01T18:29:17.72776 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:29:17.72809 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:29:17.72810 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:29:17.72811 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:29:17.73495 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:29:17.73841 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:29:17.73889 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:29:24.73897 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:29:24.74386 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6825863565 2016-12-01T18:29:24.74563 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6825863565 2016-12-01T18:29:24.80590 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:29:24.80602 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:29:24.84511 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:29:24.84514 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:29:24.84519 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:29:24.84527 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:29:24.84613 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:29:24.84614 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:29:24.84615 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:29:24.84615 0.03121747] 2016-12-01T18:29:24.84626 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:29:24.84639 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:29:24.84647 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:29:24.84655 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:29:24.84957 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:29:24.85015 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:29:24.85038 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:29:31.85091 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:29:31.85602 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6810749389 2016-12-01T18:29:31.86376 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6810749389 2016-12-01T18:29:31.92080 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:29:31.92091 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:29:31.95270 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:29:31.95272 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:29:31.95273 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:29:31.95273 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:29:31.95274 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:29:31.95275 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:29:31.95275 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:29:31.95276 0.03121747] 2016-12-01T18:29:31.95276 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:29:31.95277 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:29:31.95277 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:29:31.95278 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:29:31.95932 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:29:31.96381 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:29:31.96416 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:29:38.96461 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:29:39.01249 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6830700939 2016-12-01T18:29:39.01369 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6830700939 2016-12-01T18:29:39.07508 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:29:39.07511 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:29:39.10283 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:29:39.10289 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:29:39.10297 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:29:39.10303 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:29:39.10359 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:29:39.10360 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:29:39.10361 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:29:39.10361 0.03121747] 2016-12-01T18:29:39.10367 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:29:39.10373 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:29:39.10379 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:29:39.10385 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:29:39.10849 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:29:39.10940 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:29:39.11038 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:29:46.11138 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:29:46.12486 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6823444217 2016-12-01T18:29:46.13350 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6823444217 2016-12-01T18:29:46.18771 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:29:46.18774 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:29:46.22204 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:29:46.22211 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:29:46.22219 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:29:46.22226 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:29:46.22298 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:29:46.22300 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:29:46.22301 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:29:46.22301 0.03121747] 2016-12-01T18:29:46.22307 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:29:46.22313 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:29:46.22321 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:29:46.22328 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:29:46.22460 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:29:46.22657 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:29:46.22705 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:29:53.22723 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:29:53.23524 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6850181429 2016-12-01T18:29:53.23637 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6850181429 2016-12-01T18:29:53.29817 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:29:53.29819 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:29:53.32767 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:29:53.32769 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:29:53.32769 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:29:53.32859 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:29:53.32921 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:29:53.32922 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:29:53.32924 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:29:53.32925 0.03121747] 2016-12-01T18:29:53.32925 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:29:53.32926 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:29:53.32926 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:29:53.32927 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:29:53.33027 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:29:53.33299 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:29:53.33330 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:30:00.33363 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:30:00.35023 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6855234299 2016-12-01T18:30:00.35083 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6855234299 2016-12-01T18:30:00.41279 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:30:00.41291 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:30:00.43708 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:30:00.43715 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:30:00.43722 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:30:00.43808 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:30:00.43809 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:30:00.43809 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:30:00.43809 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:30:00.43810 0.03121747] 2016-12-01T18:30:00.43810 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:30:00.43810 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:30:00.43810 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:30:00.43811 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:30:00.43910 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:30:00.44334 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:30:00.44356 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:30:07.44525 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:30:07.47902 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6816353412 2016-12-01T18:30:07.47946 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6816353412 2016-12-01T18:30:07.54204 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:30:07.54216 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:30:07.58249 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:30:07.58251 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:30:07.58410 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:30:07.58411 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:30:07.58413 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:30:07.58414 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:30:07.58414 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:30:07.58415 0.03121747] 2016-12-01T18:30:07.58415 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:30:07.58416 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:30:07.58416 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:30:07.58417 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:30:07.58568 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:30:07.58644 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:30:07.58741 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:30:14.58775 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:30:14.59913 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6803445442 2016-12-01T18:30:14.59981 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6803445442 2016-12-01T18:30:14.66112 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:30:14.66114 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:30:14.68985 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:30:14.69138 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:30:14.69139 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:30:14.69140 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:30:14.69141 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:30:14.69141 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:30:14.69141 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:30:14.69142 0.03121747] 2016-12-01T18:30:14.69142 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:30:14.69143 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:30:14.69143 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:30:14.69144 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:30:14.69487 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:30:14.69550 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:30:14.69583 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:30:21.69604 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:30:21.70557 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6839134951 2016-12-01T18:30:21.70831 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6839134951 2016-12-01T18:30:21.76948 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:30:21.76959 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:30:21.80045 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:30:21.80052 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:30:21.80062 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:30:21.80068 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:30:21.80153 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:30:21.80154 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:30:21.80154 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:30:21.80155 0.03121747] 2016-12-01T18:30:21.80165 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:30:21.80174 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:30:21.80184 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:30:21.80193 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:30:21.80411 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:30:21.80691 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:30:21.80767 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:30:28.80802 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:30:28.81430 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6768895353 2016-12-01T18:30:28.81813 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6768895353 2016-12-01T18:30:28.88252 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:30:28.88254 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:30:28.91536 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:30:28.91544 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:30:28.91553 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:30:28.91562 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:30:28.91698 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:30:28.91699 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:30:28.91700 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:30:28.91700 0.03121747] 2016-12-01T18:30:28.91701 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:30:28.91701 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:30:28.91702 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:30:28.91702 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:30:28.92427 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:30:28.92603 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:30:28.92646 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:30:35.93811 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:30:35.99217 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6866795546 2016-12-01T18:30:35.99679 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6866795546 2016-12-01T18:30:36.05564 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:30:36.05566 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:30:36.08772 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:30:36.08779 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:30:36.08787 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:30:36.08797 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:30:36.08886 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:30:36.08887 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:30:36.08887 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:30:36.08888 0.03121747] 2016-12-01T18:30:36.08900 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:30:36.08909 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:30:36.08920 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:30:36.08931 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:30:36.09270 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:30:36.09722 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:30:36.09752 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:30:43.09807 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:30:43.11618 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6744895123 2016-12-01T18:30:43.11731 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6744895123 2016-12-01T18:30:43.18197 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:30:43.18217 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:30:43.21363 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:30:43.21365 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:30:43.21365 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:30:43.21366 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:30:43.21366 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:30:43.21366 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:30:43.21367 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:30:43.21367 0.03121747] 2016-12-01T18:30:43.21367 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:30:43.21368 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:30:43.21368 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:30:43.21369 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:30:43.21470 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:30:43.21527 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:30:43.21559 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:30:50.21585 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:30:50.21973 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6763264392 2016-12-01T18:30:50.22224 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6763264392 2016-12-01T18:30:50.28315 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:30:50.28629 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:30:50.31518 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:30:50.31523 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:30:50.31676 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:30:50.31677 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:30:50.31677 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:30:50.31678 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:30:50.31678 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:30:50.31679 0.03121747] 2016-12-01T18:30:50.31679 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:30:50.31679 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:30:50.31679 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:30:50.31680 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:30:50.31917 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:30:50.32063 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:30:50.32586 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:30:57.32354 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:30:57.33957 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6746994541 2016-12-01T18:30:57.34065 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6746994541 2016-12-01T18:30:57.40573 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:30:57.40612 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:30:57.42337 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:30:57.42345 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:30:57.42354 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:30:57.42362 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:30:57.42453 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:30:57.42454 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:30:57.42455 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:30:57.42455 0.03121747] 2016-12-01T18:30:57.42470 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:30:57.42474 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:30:57.42482 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:30:57.42490 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:30:57.43253 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:30:57.43354 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:30:57.43382 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:31:04.43392 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:31:04.44789 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6791840869 2016-12-01T18:31:04.45417 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6791840869 2016-12-01T18:31:04.52189 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:31:04.52192 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:31:04.55166 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:31:04.55168 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:31:04.55168 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:31:04.55169 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:31:04.55169 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:31:04.55170 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:31:04.55170 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:31:04.55171 0.03121747] 2016-12-01T18:31:04.55176 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:31:04.55187 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:31:04.55390 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:31:04.55392 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:31:04.55528 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:31:04.55603 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:31:04.55633 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:31:11.55654 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:31:11.61523 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6807587705 2016-12-01T18:31:11.61582 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6807587705 2016-12-01T18:31:11.67796 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:31:11.67808 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:31:11.71616 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:31:11.71618 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:31:11.71619 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:31:11.71619 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:31:11.71712 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:31:11.71713 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:31:11.71714 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:31:11.71714 0.03121747] 2016-12-01T18:31:11.71725 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:31:11.71735 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:31:11.71746 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:31:11.71757 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:31:11.72338 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:31:11.72722 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:31:11.73263 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:31:18.73315 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:31:18.73856 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.67405589 2016-12-01T18:31:18.73991 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.67405589 2016-12-01T18:31:18.80497 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:31:18.80500 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:31:18.88682 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:31:18.88684 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:31:18.88685 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:31:18.88685 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:31:18.88686 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:31:18.88686 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:31:18.88687 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:31:18.88687 0.03121747] 2016-12-01T18:31:18.88688 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:31:18.88690 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:31:18.88690 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:31:18.88691 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:31:18.88770 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:31:18.89753 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:31:18.89794 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:31:25.89912 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:31:25.90555 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6746108255 2016-12-01T18:31:25.90898 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6746108255 2016-12-01T18:31:25.96780 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:31:25.96782 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:31:25.99469 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:31:25.99471 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:31:25.99472 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:31:25.99473 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:31:25.99710 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:31:25.99711 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:31:25.99712 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:31:25.99712 0.03121747] 2016-12-01T18:31:25.99713 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:31:25.99713 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:31:25.99714 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:31:25.99716 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:31:26.00002 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:31:26.00067 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:31:26.00100 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:31:33.00152 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:31:33.02114 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6816271955 2016-12-01T18:31:33.02169 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6816271955 2016-12-01T18:31:33.08406 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:31:33.08408 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:31:33.14007 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:31:33.14025 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:31:33.14027 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:31:33.14038 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:31:33.14127 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:31:33.14128 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:31:33.14129 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:31:33.14129 0.03121747] 2016-12-01T18:31:33.14137 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:31:33.14144 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:31:33.14152 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:31:33.14160 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:31:33.15281 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:31:33.15901 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:31:33.15999 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:31:40.16142 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:31:40.18596 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6729502766 2016-12-01T18:31:40.19023 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6729502766 2016-12-01T18:31:40.24947 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:31:40.24977 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:31:40.27826 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:31:40.27833 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:31:40.27841 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:31:40.27848 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:31:40.27987 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:31:40.27988 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:31:40.27989 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:31:40.27989 0.03121747] 2016-12-01T18:31:40.27991 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:31:40.27992 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:31:40.27992 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:31:40.27992 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:31:40.28878 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:31:40.28951 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:31:40.29557 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:31:47.29551 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:31:47.34504 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6801853454 2016-12-01T18:31:47.34620 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6801853454 2016-12-01T18:31:47.40799 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:31:47.40802 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:31:47.50324 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:31:47.50326 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:31:47.50327 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:31:47.50327 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:31:47.50391 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:31:47.50392 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:31:47.50393 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:31:47.50393 0.03121747] 2016-12-01T18:31:47.50394 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:31:47.50394 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:31:47.50395 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:31:47.50395 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:31:47.51438 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:31:47.51615 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:31:47.51753 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:31:54.51700 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:31:54.56200 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6767650099 2016-12-01T18:31:54.56473 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6767650099 2016-12-01T18:31:54.62722 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:31:54.62725 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:31:54.65051 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:31:54.65053 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:31:54.65053 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:31:54.65054 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:31:54.65055 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:31:54.65057 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:31:54.65057 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:31:54.65058 0.03121747] 2016-12-01T18:31:54.65058 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:31:54.65059 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:31:54.65059 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:31:54.65060 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:31:54.65296 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:31:54.65709 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:31:54.65733 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:32:01.65757 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:32:01.66389 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6843845346 2016-12-01T18:32:01.66572 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6843845346 2016-12-01T18:32:01.72664 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:32:01.72666 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:32:01.75864 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:32:01.75870 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:32:01.75877 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:32:01.75884 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:32:01.76029 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:32:01.76030 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:32:01.76031 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:32:01.76031 0.03121747] 2016-12-01T18:32:01.76032 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:32:01.76032 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:32:01.76032 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:32:01.76033 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:32:01.77791 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:32:01.78455 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:32:01.78487 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:32:08.78628 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:32:08.83194 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6749226907 2016-12-01T18:32:08.83255 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6749226907 2016-12-01T18:32:08.89781 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:32:08.89783 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:32:08.93271 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:32:08.93273 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:32:08.93275 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:32:08.93276 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:32:08.93326 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:32:08.93327 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:32:08.93327 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:32:08.93328 0.03121747] 2016-12-01T18:32:08.93808 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:32:08.93810 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:32:08.93811 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:32:08.93811 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:32:08.93812 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:32:08.94005 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:32:08.94007 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:32:15.94025 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:32:15.94325 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6787105492 2016-12-01T18:32:15.94437 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6787105492 2016-12-01T18:32:16.00540 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:32:16.00815 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:32:16.04007 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:32:16.04009 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:32:16.04010 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:32:16.04010 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:32:16.04011 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:32:16.04011 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:32:16.04012 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:32:16.04012 0.03121747] 2016-12-01T18:32:16.04013 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:32:16.04013 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:32:16.04014 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:32:16.04014 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:32:16.04815 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:32:16.04883 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:32:16.04995 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:32:23.04934 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:32:23.05205 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6770762611 2016-12-01T18:32:23.05840 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6770762611 2016-12-01T18:32:23.11286 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:32:23.11289 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:32:23.14631 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:32:23.14640 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:32:23.14819 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:32:23.14820 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:32:23.14821 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:32:23.14822 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:32:23.14823 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:32:23.14823 0.03121747] 2016-12-01T18:32:23.14823 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:32:23.14825 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:32:23.14825 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:32:23.14826 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:32:23.15461 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:32:23.15525 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:32:23.15562 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:32:30.15616 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:32:30.16369 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6755875872 2016-12-01T18:32:30.16928 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6755875872 2016-12-01T18:32:30.22568 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:32:30.22587 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:32:30.25523 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:32:30.25525 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:32:30.25526 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:32:30.26319 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:32:30.26322 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:32:30.26322 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:32:30.26323 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:32:30.26323 0.03121747] 2016-12-01T18:32:30.26324 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:32:30.26324 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:32:30.26325 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:32:30.26325 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:32:30.26326 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:32:30.27010 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:32:30.27151 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:32:37.27086 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:32:37.32581 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6828689924 2016-12-01T18:32:37.32630 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6828689924 2016-12-01T18:32:37.39372 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:32:37.39385 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:32:37.41978 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:32:37.41990 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:32:37.42002 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:32:37.42013 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:32:37.42110 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:32:37.42111 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:32:37.42112 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:32:37.42112 0.03121747] 2016-12-01T18:32:37.42124 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:32:37.42134 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:32:37.42145 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:32:37.42156 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:32:37.42324 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:32:37.42391 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:32:37.42511 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:32:44.42563 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:32:44.43348 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6768190403 2016-12-01T18:32:44.43706 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6768190403 2016-12-01T18:32:44.49592 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:32:44.49671 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:32:44.52168 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:32:44.52169 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:32:44.52170 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:32:44.52171 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:32:44.52258 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:32:44.52259 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:32:44.52260 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:32:44.52260 0.03121747] 2016-12-01T18:32:44.52261 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:32:44.52261 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:32:44.52262 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:32:44.52281 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:32:44.52698 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:32:44.52800 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:32:44.52834 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:32:51.52875 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:32:51.55010 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.677252594 2016-12-01T18:32:51.55333 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.677252594 2016-12-01T18:32:51.61405 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:32:51.61407 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:32:51.66015 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:32:51.66017 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:32:51.66017 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:32:51.66017 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:32:51.66018 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:32:51.66018 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:32:51.66018 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:32:51.66019 0.03121747] 2016-12-01T18:32:51.66019 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:32:51.66019 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:32:51.66020 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:32:51.66020 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:32:51.66489 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:32:51.66554 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:32:51.66586 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:32:58.66618 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:32:58.71366 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6741613694 2016-12-01T18:32:58.71441 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6741613694 2016-12-01T18:32:58.77614 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:32:58.77616 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:32:58.80297 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:32:58.80309 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:32:58.80322 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:32:58.80333 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:32:58.80435 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:32:58.80436 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:32:58.80437 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:32:58.80437 0.03121747] 2016-12-01T18:32:58.80449 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:32:58.80459 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:32:58.80470 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:32:58.80481 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:32:58.81035 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:32:58.82204 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:32:58.82238 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:33:05.82286 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:33:05.83370 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6745870773 2016-12-01T18:33:05.83420 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6745870773 2016-12-01T18:33:05.89154 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:33:05.89175 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:33:05.92281 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:33:05.92292 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:33:05.92304 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:33:05.92314 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:33:05.92412 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:33:05.92413 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:33:05.92413 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:33:05.92414 0.03121747] 2016-12-01T18:33:05.92425 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:33:05.92435 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:33:05.92446 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:33:05.92457 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:33:05.93576 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:33:05.93643 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:33:05.93667 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:33:12.93683 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:33:12.99441 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6809291094 2016-12-01T18:33:12.99790 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6809291094 2016-12-01T18:33:13.05534 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:33:13.05536 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:33:13.48421 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:33:13.48428 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:33:13.48435 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:33:13.48442 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:33:13.48496 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:33:13.48497 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:33:13.48497 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:33:13.48498 0.03121747] 2016-12-01T18:33:13.48536 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:33:13.48537 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:33:13.48538 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:33:13.48538 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:33:13.48765 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:33:13.48875 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:33:13.49536 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:33:20.49595 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:33:20.53617 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6720057201 2016-12-01T18:33:20.53664 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6720057201 2016-12-01T18:33:20.59848 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:33:20.59860 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:33:20.62657 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:33:20.62659 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:33:20.62659 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:33:20.62660 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:33:20.62660 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:33:20.62661 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:33:20.62661 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:33:20.62662 0.03121747] 2016-12-01T18:33:20.62662 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:33:20.62663 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:33:20.62663 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:33:20.62664 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:33:20.63783 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:33:20.63879 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:33:20.63916 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:33:27.64009 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:33:27.70071 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6755684591 2016-12-01T18:33:27.70133 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6755684591 2016-12-01T18:33:27.76410 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:33:27.76412 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:33:27.83329 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:33:27.83332 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:33:27.83332 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:33:27.83333 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:33:27.83355 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:33:27.83356 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:33:27.83356 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:33:27.83357 0.03121747] 2016-12-01T18:33:27.83364 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:33:27.83394 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:33:27.83396 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:33:27.83397 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:33:27.83486 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:33:27.83903 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:33:27.83927 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:33:34.83961 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:33:34.87657 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6766124796 2016-12-01T18:33:34.87934 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6766124796 2016-12-01T18:33:34.93804 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:33:34.93821 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:33:34.96572 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:33:34.96575 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:33:34.96575 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:33:34.96576 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:33:34.96576 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:33:34.96577 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:33:34.96577 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:33:34.96578 0.03121747] 2016-12-01T18:33:34.96578 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:33:34.96579 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:33:34.96579 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:33:34.96580 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:33:34.96764 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:33:34.96837 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:33:34.96900 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:33:41.96861 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:33:41.98231 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6735493995 2016-12-01T18:33:41.98646 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6735493995 2016-12-01T18:33:42.04584 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:33:42.04586 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:33:42.11100 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:33:42.11102 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:33:42.11103 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:33:42.11104 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:33:42.11104 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:33:42.11105 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:33:42.11107 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:33:42.11107 0.03121747] 2016-12-01T18:33:42.11108 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:33:42.11108 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:33:42.11109 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:33:42.11109 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:33:42.11313 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:33:42.12344 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:33:42.12524 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:33:49.12745 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:33:49.15347 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6733161854 2016-12-01T18:33:49.15840 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6733161854 2016-12-01T18:33:49.21499 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:33:49.21520 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:33:49.25225 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:33:49.25237 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:33:49.25252 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:33:49.25259 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:33:49.25312 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:33:49.25313 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:33:49.25313 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:33:49.25314 0.03121747] 2016-12-01T18:33:49.25320 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:33:49.25325 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:33:49.25332 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:33:49.25338 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:33:49.25427 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:33:49.26117 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:33:49.26175 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:33:56.26235 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:33:56.31997 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.673784502 2016-12-01T18:33:56.32059 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.673784502 2016-12-01T18:33:56.38421 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:33:56.38437 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:33:56.42347 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:33:56.42355 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:33:56.42365 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:33:56.42373 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:33:56.42470 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:33:56.42471 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:33:56.42471 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:33:56.42472 0.03121747] 2016-12-01T18:33:56.42479 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:33:56.42487 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:33:56.42495 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:33:56.42503 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:33:56.43022 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:33:56.43024 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:33:56.43025 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:34:03.43003 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:34:03.43158 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6710993871 2016-12-01T18:34:03.43550 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6710993871 2016-12-01T18:34:03.49616 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:34:03.49618 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:34:03.52534 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:34:03.52536 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:34:03.52536 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:34:03.52537 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:34:03.52537 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:34:03.52537 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:34:03.52538 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:34:03.52538 0.03121747] 2016-12-01T18:34:03.52538 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:34:03.52539 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:34:03.52539 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:34:03.52539 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:34:03.53369 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:34:03.53534 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:34:03.53655 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:34:10.53697 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:34:10.54013 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6773220615 2016-12-01T18:34:10.54346 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6773220615 2016-12-01T18:34:10.60088 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:34:10.60121 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:34:10.63049 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:34:10.63060 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:34:10.63066 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:34:10.63171 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:34:10.63173 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:34:10.63173 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:34:10.63174 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:34:10.63174 0.03121747] 2016-12-01T18:34:10.63191 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:34:10.63191 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:34:10.63222 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:34:10.63223 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:34:10.63886 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:34:10.64303 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:34:10.64351 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:34:17.64442 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:34:17.64568 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6725381729 2016-12-01T18:34:17.64993 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6725381729 2016-12-01T18:34:17.70861 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:34:17.70894 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:34:17.73825 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:34:17.73827 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:34:17.73828 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:34:17.73828 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:34:17.73828 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:34:17.73829 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:34:17.73829 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:34:17.73829 0.03121747] 2016-12-01T18:34:17.73830 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:34:17.73830 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:34:17.73830 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:34:17.73831 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:34:17.74259 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:34:17.74411 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:34:17.74495 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:34:24.74467 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:34:24.77450 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6760079052 2016-12-01T18:34:24.77927 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6760079052 2016-12-01T18:34:24.83361 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:34:24.83381 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:34:24.86078 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:34:24.86084 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:34:24.86094 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:34:24.86104 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:34:24.86200 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:34:24.86202 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:34:24.86202 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:34:24.86203 0.03121747] 2016-12-01T18:34:24.86214 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:34:24.86226 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:34:24.86238 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:34:24.86249 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:34:24.87501 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:34:24.87637 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:34:24.87744 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:34:31.87786 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:34:31.93608 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6841437029 2016-12-01T18:34:31.93829 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6841437029 2016-12-01T18:34:32.00185 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:34:32.00187 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:34:32.04802 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:34:32.04805 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:34:32.04957 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:34:32.04958 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:34:32.04959 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:34:32.04959 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:34:32.04960 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:34:32.04960 0.03121747] 2016-12-01T18:34:32.04961 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:34:32.04961 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:34:32.04962 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:34:32.04962 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:34:32.05755 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:34:32.06415 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:34:32.06445 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:34:39.06560 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:34:39.10975 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6781367673 2016-12-01T18:34:39.11038 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6781367673 2016-12-01T18:34:39.17180 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:34:39.17183 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:34:39.19940 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:34:39.19942 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:34:39.19942 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:34:39.19943 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:34:39.19943 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:34:39.19944 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:34:39.19944 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:34:39.19945 0.03121747] 2016-12-01T18:34:39.19945 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:34:39.19946 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:34:39.19946 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:34:39.19946 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:34:39.20786 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:34:39.21106 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:34:39.21140 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:34:46.21280 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:34:46.21624 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6750023165 2016-12-01T18:34:46.21807 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6750023165 2016-12-01T18:34:46.27896 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:34:46.27898 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:34:46.31380 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:34:46.31383 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:34:46.31389 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:34:46.31396 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:34:46.31478 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:34:46.31479 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:34:46.31480 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:34:46.31480 0.03121747] 2016-12-01T18:34:46.31503 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:34:46.31513 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:34:46.31527 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:34:46.31538 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:34:46.31776 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:34:46.31840 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:34:46.32072 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:34:53.32117 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:34:53.38943 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6727300001 2016-12-01T18:34:53.39384 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6727300001 2016-12-01T18:34:53.44799 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:34:53.44801 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:34:53.49378 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:34:53.49489 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:34:53.49490 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:34:53.49491 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:34:53.49547 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:34:53.49549 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:34:53.49549 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:34:53.49550 0.03121747] 2016-12-01T18:34:53.49550 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:34:53.49551 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:34:53.49551 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:34:53.49552 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:34:53.51108 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:34:53.51794 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:34:53.51796 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:35:00.51760 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:35:00.54890 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6748840507 2016-12-01T18:35:00.55178 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6748840507 2016-12-01T18:35:00.61124 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:35:00.61126 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:35:00.64266 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:35:00.64273 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:35:00.64280 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:35:00.64287 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:35:00.64382 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:35:00.64383 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:35:00.64384 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:35:00.64384 0.03121747] 2016-12-01T18:35:00.64396 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:35:00.64406 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:35:00.64417 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:35:00.64431 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:35:00.65011 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:35:00.65482 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:35:00.65516 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:35:07.65711 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:35:07.66249 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6711803522 2016-12-01T18:35:07.66324 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6711803522 2016-12-01T18:35:07.72638 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:35:07.72640 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:35:07.75522 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:35:07.75524 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:35:07.75525 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:35:07.75525 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:35:07.75526 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:35:07.75526 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:35:07.75527 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:35:07.75527 0.03121747] 2016-12-01T18:35:07.75528 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:35:07.75529 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:35:07.75601 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:35:07.75602 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:35:07.75745 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:35:07.75810 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:35:07.75844 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:35:14.76043 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:35:14.81601 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.677222673 2016-12-01T18:35:14.81669 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.677222673 2016-12-01T18:35:14.88154 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:35:14.88157 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:35:14.92345 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:35:14.92347 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:35:14.92348 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:35:14.92348 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:35:14.92349 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:35:14.92349 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:35:14.92350 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:35:14.92350 0.03121747] 2016-12-01T18:35:14.92351 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:35:14.92351 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:35:14.92352 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:35:14.92352 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:35:14.92877 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:35:14.92961 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:35:14.92989 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:35:21.93015 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:35:21.93330 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.67292738 2016-12-01T18:35:21.93736 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.67292738 2016-12-01T18:35:21.99622 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:35:21.99652 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:35:22.02330 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:35:22.02332 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:35:22.02333 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:35:22.02333 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:35:22.02334 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:35:22.02334 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:35:22.02335 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:35:22.02335 0.03121747] 2016-12-01T18:35:22.02336 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:35:22.02336 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:35:22.02337 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:35:22.02337 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:35:22.02490 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:35:22.02556 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:35:22.02586 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:35:29.02667 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:35:29.04383 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6790768355 2016-12-01T18:35:29.04860 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6790768355 2016-12-01T18:35:29.10694 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:35:29.10732 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:35:29.14554 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:35:29.14793 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:35:29.14794 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:35:29.14795 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:35:29.14795 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:35:29.14796 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:35:29.14797 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:35:29.14797 0.03121747] 2016-12-01T18:35:29.14799 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:35:29.14800 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:35:29.14800 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:35:29.14801 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:35:29.15010 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:35:29.15276 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:35:29.15326 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:35:36.15485 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:35:36.21506 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6777963313 2016-12-01T18:35:36.21773 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6777963313 2016-12-01T18:35:36.27899 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:35:36.27901 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:35:36.31132 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:35:36.31134 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:35:36.31134 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:35:36.31135 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:35:36.31135 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:35:36.31135 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:35:36.31136 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:35:36.31136 0.03121747] 2016-12-01T18:35:36.31137 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:35:36.31171 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:35:36.31172 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:35:36.31173 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:35:36.31265 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:35:36.31329 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:35:36.31363 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:35:43.31374 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:35:43.31654 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6765058689 2016-12-01T18:35:43.31724 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6765058689 2016-12-01T18:35:43.38420 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:35:43.38788 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:35:43.41238 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:35:43.41448 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:35:43.41450 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:35:43.41450 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:35:43.41451 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:35:43.41453 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:35:43.41453 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:35:43.41454 0.03121747] 2016-12-01T18:35:43.41454 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:35:43.41455 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:35:43.41455 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:35:43.41456 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:35:43.42421 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:35:43.42502 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:35:43.42562 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:35:50.42584 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:35:50.48449 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6763424178 2016-12-01T18:35:50.48507 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6763424178 2016-12-01T18:35:50.54758 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:35:50.54760 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:35:50.58507 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:35:50.58509 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:35:50.58509 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:35:50.58510 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:35:50.58510 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:35:50.58510 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:35:50.58511 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:35:50.58511 0.03121747] 2016-12-01T18:35:50.58512 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:35:50.58512 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:35:50.58513 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:35:50.58513 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:35:50.58761 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:35:50.58809 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:35:50.58832 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:35:57.58993 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:35:57.59603 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6783899956 2016-12-01T18:35:57.59646 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6783899956 2016-12-01T18:35:57.65728 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:35:57.65730 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:35:57.69341 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:35:57.69343 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:35:57.69343 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:35:57.69345 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:35:57.69346 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:35:57.69346 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:35:57.69347 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:35:57.69347 0.03121747] 2016-12-01T18:35:57.69348 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:35:57.69348 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:35:57.69349 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:35:57.69349 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:35:57.69429 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:35:57.69493 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:35:57.69934 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:36:04.69693 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:36:04.70036 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6772708311 2016-12-01T18:36:04.70105 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6772708311 2016-12-01T18:36:04.76462 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:36:04.76465 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:36:04.80062 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:36:04.80068 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:36:04.80076 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:36:04.80082 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:36:04.80149 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:36:04.80150 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:36:04.80151 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:36:04.80151 0.03121747] 2016-12-01T18:36:04.80163 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:36:04.80173 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:36:04.80185 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:36:04.80195 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:36:04.80772 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:36:04.81127 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:36:04.81220 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:36:11.81324 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:36:11.87075 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6671027125 2016-12-01T18:36:11.87138 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6671027125 2016-12-01T18:36:11.93434 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:36:11.93436 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:36:11.96935 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:36:11.96947 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:36:11.96959 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:36:11.96970 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:36:11.97067 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:36:11.97068 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:36:11.97069 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:36:11.97069 0.03121747] 2016-12-01T18:36:11.97081 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:36:11.97091 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:36:11.97102 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:36:11.97113 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:36:11.97225 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:36:11.97290 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:36:11.97322 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:36:18.97350 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:36:18.97998 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6668282642 2016-12-01T18:36:18.98047 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6668282642 2016-12-01T18:36:19.04822 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:36:19.04824 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:36:19.07864 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:36:19.07871 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:36:19.07878 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:36:19.07885 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:36:19.07941 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:36:19.07942 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:36:19.07943 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:36:19.07943 0.03121747] 2016-12-01T18:36:19.07949 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:36:19.07954 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:36:19.07961 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:36:19.07969 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:36:19.10387 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:36:19.10551 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:36:19.10573 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:36:26.10628 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:36:26.14228 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6696935471 2016-12-01T18:36:26.14425 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6696935471 2016-12-01T18:36:26.20568 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:36:26.20570 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:36:26.25531 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:36:26.25533 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:36:26.25533 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:36:26.25534 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:36:26.25534 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:36:26.25535 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:36:26.25535 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:36:26.25536 0.03121747] 2016-12-01T18:36:26.25536 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:36:26.25537 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:36:26.25537 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:36:26.25538 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:36:26.25964 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:36:26.26075 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:36:26.26123 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:36:33.26386 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:36:33.31937 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6672481738 2016-12-01T18:36:33.31939 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6672481738 2016-12-01T18:36:33.38010 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:36:33.38012 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:36:33.49189 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:36:33.49191 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:36:33.49192 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:36:33.49192 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:36:33.49213 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:36:33.49214 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:36:33.49214 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:36:33.49215 0.03121747] 2016-12-01T18:36:33.49221 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:36:33.49226 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:36:33.49233 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:36:33.49239 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:36:33.50114 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:36:33.50510 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:36:33.50767 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:36:40.50781 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:36:40.55759 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6670185701 2016-12-01T18:36:40.55761 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6670185701 2016-12-01T18:36:40.61825 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:36:40.61838 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:36:40.64996 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:36:40.65008 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:36:40.65019 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:36:40.65030 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:36:40.65130 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:36:40.65131 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:36:40.65132 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:36:40.65132 0.03121747] 2016-12-01T18:36:40.65145 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:36:40.65155 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:36:40.65166 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:36:40.65176 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:36:40.65637 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:36:40.65707 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:36:40.65877 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:36:47.66168 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:36:47.71667 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6628992604 2016-12-01T18:36:47.71720 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6628992604 2016-12-01T18:36:47.78267 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:36:47.78269 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:36:47.81465 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:36:47.81467 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:36:47.81468 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:36:47.81468 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:36:47.81510 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:36:47.81511 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:36:47.81511 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:36:47.81512 0.03121747] 2016-12-01T18:36:47.81524 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:36:47.81533 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:36:47.81543 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:36:47.81553 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:36:47.81890 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:36:47.81943 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:36:47.81966 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:36:54.82060 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:36:54.84742 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6698251805 2016-12-01T18:36:54.85139 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6698251805 2016-12-01T18:36:54.91345 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:36:54.91348 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:36:54.94151 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:36:54.94154 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:36:54.94154 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:36:54.94155 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:36:54.94155 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:36:54.94156 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:36:54.94156 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:36:54.94157 0.03121747] 2016-12-01T18:36:54.94157 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:36:54.94158 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:36:54.94158 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:36:54.94159 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:36:54.95462 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:36:54.96996 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:36:54.97302 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:37:01.97720 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:37:02.03271 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6688845062 2016-12-01T18:37:02.03686 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6688845062 2016-12-01T18:37:02.09220 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:37:02.09222 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:37:02.12573 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:37:02.12576 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:37:02.12576 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:37:02.12577 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:37:02.12577 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:37:02.12578 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:37:02.12578 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:37:02.12579 0.03121747] 2016-12-01T18:37:02.12579 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:37:02.12579 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:37:02.12580 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:37:02.12580 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:37:02.12813 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:37:02.12883 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:37:02.13285 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:37:09.13478 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:37:09.14017 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6662818183 2016-12-01T18:37:09.14694 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6662818183 2016-12-01T18:37:09.20102 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:37:09.20136 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:37:09.23616 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:37:09.23618 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:37:09.23619 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:37:09.23619 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:37:09.23620 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:37:09.23620 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:37:09.23621 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:37:09.23621 0.03121747] 2016-12-01T18:37:09.23622 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:37:09.23622 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:37:09.23623 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:37:09.23623 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:37:09.23713 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:37:09.23882 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:37:09.23919 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:37:16.23952 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:37:16.25412 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6678431702 2016-12-01T18:37:16.25761 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6678431702 2016-12-01T18:37:16.31897 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:37:16.31909 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:37:16.36096 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:37:16.36108 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:37:16.36123 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:37:16.36128 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:37:16.36205 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:37:16.36206 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:37:16.36207 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:37:16.36207 0.03121747] 2016-12-01T18:37:16.36214 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:37:16.36221 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:37:16.36233 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:37:16.36244 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:37:16.36361 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:37:16.36807 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:37:16.36844 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:37:23.36954 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:37:23.42140 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6666444919 2016-12-01T18:37:23.42385 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6666444919 2016-12-01T18:37:23.47923 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:37:23.47934 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:37:23.52373 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:37:23.52380 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:37:23.52389 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:37:23.52398 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:37:23.52512 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:37:23.52513 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:37:23.52514 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:37:23.52514 0.03121747] 2016-12-01T18:37:23.52515 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:37:23.52515 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:37:23.52516 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:37:23.52516 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:37:23.53505 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:37:23.53573 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:37:23.53604 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:37:30.54066 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:37:30.58805 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6647065769 2016-12-01T18:37:30.58987 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6647065769 2016-12-01T18:37:30.65218 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:37:30.65239 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:37:30.68441 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:37:30.68453 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:37:30.68466 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:37:30.68477 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:37:30.68570 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:37:30.68571 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:37:30.68572 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:37:30.68573 0.03121747] 2016-12-01T18:37:30.68585 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:37:30.68595 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:37:30.68606 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:37:30.68616 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:37:30.69068 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:37:30.69136 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:37:30.69168 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:37:37.69182 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:37:37.75325 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6724742997 2016-12-01T18:37:37.75772 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6724742997 2016-12-01T18:37:37.82005 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:37:37.82007 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:37:37.84746 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:37:37.84750 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:37:37.84751 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:37:37.84751 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:37:37.84752 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:37:37.84752 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:37:37.84753 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:37:37.84753 0.03121747] 2016-12-01T18:37:37.84753 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:37:37.84754 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:37:37.84754 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:37:37.84755 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:37:37.85482 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:37:37.85930 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:37:37.85962 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:37:44.85977 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:37:44.86111 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6653506736 2016-12-01T18:37:44.86551 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6653506736 2016-12-01T18:37:44.92369 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:37:44.92390 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:37:44.95292 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:37:44.95300 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:37:44.95309 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:37:44.95318 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:37:44.95420 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:37:44.95421 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:37:44.95422 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:37:44.95422 0.03121747] 2016-12-01T18:37:44.95434 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:37:44.95444 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:37:44.95455 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:37:44.95466 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:37:44.95694 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:37:44.95875 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:37:44.96424 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:37:51.95928 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:37:51.97035 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6674303319 2016-12-01T18:37:51.97248 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6674303319 2016-12-01T18:37:52.03562 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:37:52.03565 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:37:52.06967 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:37:52.06969 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:37:52.06969 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:37:52.06970 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:37:52.06970 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:37:52.06971 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:37:52.06971 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:37:52.06972 0.03121747] 2016-12-01T18:37:52.06972 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:37:52.06973 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:37:52.06974 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:37:52.06974 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:37:52.07042 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:37:52.07113 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:37:52.07192 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:37:59.07221 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:37:59.14337 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6638248693 2016-12-01T18:37:59.14569 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6638248693 2016-12-01T18:37:59.20234 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:37:59.20237 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:37:59.25266 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:37:59.25269 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:37:59.25270 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:37:59.25270 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:37:59.25271 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:37:59.25271 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:37:59.25272 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:37:59.25272 0.03121747] 2016-12-01T18:37:59.25273 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:37:59.25273 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:37:59.25274 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:37:59.25274 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:37:59.25494 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:37:59.25686 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:37:59.25838 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:38:06.25919 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:38:06.30790 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6613377699 2016-12-01T18:38:06.30924 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6613377699 2016-12-01T18:38:06.37528 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:38:06.37530 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:38:06.41199 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:38:06.41201 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:38:06.41202 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:38:06.41202 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:38:06.41279 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:38:06.41280 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:38:06.41281 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:38:06.41281 0.03121747] 2016-12-01T18:38:06.41282 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:38:06.41282 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:38:06.41283 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:38:06.41283 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:38:06.41546 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:38:06.41616 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:38:06.41643 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:38:13.41672 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:38:13.47923 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6618111672 2016-12-01T18:38:13.48621 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6618111672 2016-12-01T18:38:13.54635 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:38:13.54637 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:38:13.63525 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:38:13.63528 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:38:13.63528 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:38:13.63670 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:38:13.63671 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:38:13.63672 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:38:13.63673 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:38:13.63673 0.03121747] 2016-12-01T18:38:13.63673 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:38:13.63674 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:38:13.63674 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:38:13.63675 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:38:13.64443 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:38:13.65517 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:38:13.65565 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:38:20.65593 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:38:20.71514 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6612628325 2016-12-01T18:38:20.71869 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6612628325 2016-12-01T18:38:20.77627 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:38:20.77630 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:38:20.81295 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:38:20.81303 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:38:20.81312 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:38:20.81483 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:38:20.81484 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:38:20.81485 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:38:20.81485 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:38:20.81486 0.03121747] 2016-12-01T18:38:20.81486 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:38:20.81487 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:38:20.81487 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:38:20.81488 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:38:20.81690 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:38:20.81870 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:38:20.81901 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:38:27.81939 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:38:27.88467 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6629824285 2016-12-01T18:38:27.88779 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6629824285 2016-12-01T18:38:27.94093 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:38:27.94106 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:38:27.97094 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:38:27.97096 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:38:27.97096 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:38:27.97097 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:38:27.97190 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:38:27.97192 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:38:27.97192 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:38:27.97193 0.03121747] 2016-12-01T18:38:27.97193 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:38:27.97193 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:38:27.97194 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:38:27.97194 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:38:27.97508 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:38:27.97578 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:38:27.98001 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:38:34.97610 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:38:34.98900 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6591416662 2016-12-01T18:38:34.99453 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6591416662 2016-12-01T18:38:35.04970 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:38:35.05003 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:38:35.09602 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:38:35.09605 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:38:35.09605 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:38:35.09606 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:38:35.09606 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:38:35.09607 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:38:35.09607 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:38:35.09608 0.03121747] 2016-12-01T18:38:35.09608 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:38:35.09609 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:38:35.09609 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:38:35.09609 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:38:35.09840 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:38:35.09890 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:38:35.09920 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:38:42.09964 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:38:42.15741 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6623596594 2016-12-01T18:38:42.15840 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6623596594 2016-12-01T18:38:42.21936 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:38:42.21938 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:38:42.25301 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:38:42.25303 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:38:42.25304 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:38:42.25304 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:38:42.25305 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:38:42.25305 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:38:42.25306 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:38:42.25306 0.03121747] 2016-12-01T18:38:42.25307 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:38:42.25307 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:38:42.25308 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:38:42.25308 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:38:42.25369 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:38:42.25433 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:38:42.25590 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:38:49.25482 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:38:49.26083 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6642932922 2016-12-01T18:38:49.26336 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6642932922 2016-12-01T18:38:49.32099 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:38:49.32111 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:38:49.35479 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:38:49.35481 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:38:49.35482 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:38:49.35482 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:38:49.35483 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:38:49.35483 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:38:49.35484 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:38:49.35484 0.03121747] 2016-12-01T18:38:49.35485 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:38:49.35485 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:38:49.35486 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:38:49.35486 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:38:49.35985 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:38:49.36304 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:38:49.36338 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:38:56.36365 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:38:56.36807 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6618199897 2016-12-01T18:38:56.36946 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6618199897 2016-12-01T18:38:56.43276 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:38:56.43278 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:38:56.46000 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:38:56.46006 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:38:56.46014 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:38:56.46020 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:38:56.46073 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:38:56.46074 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:38:56.46075 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:38:56.46076 0.03121747] 2016-12-01T18:38:56.46081 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:38:56.46087 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:38:56.46094 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:38:56.46101 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:38:56.46206 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:38:56.46259 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:38:56.46281 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:39:03.46300 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:39:03.47751 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6592113284 2016-12-01T18:39:03.47753 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6592113284 2016-12-01T18:39:03.53830 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:39:03.53846 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:39:03.56721 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:39:03.56723 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:39:03.56723 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:39:03.56723 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:39:03.56728 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:39:03.56729 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:39:03.56730 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:39:03.56731 0.03121747] 2016-12-01T18:39:03.56743 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:39:03.56753 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:39:03.56763 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:39:03.56774 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:39:03.57118 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:39:03.57189 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:39:03.57221 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:39:10.57231 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:39:10.57478 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6620770295 2016-12-01T18:39:10.57543 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6620770295 2016-12-01T18:39:10.63791 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:39:10.63793 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:39:10.67285 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:39:10.67287 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:39:10.67287 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:39:10.67288 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:39:10.67364 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:39:10.67365 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:39:10.67366 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:39:10.67367 0.03121747] 2016-12-01T18:39:10.67367 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:39:10.67368 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:39:10.67368 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:39:10.67368 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:39:10.67548 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:39:10.67621 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:39:10.67751 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:39:17.67788 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:39:17.73441 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6627194906 2016-12-01T18:39:17.73572 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6627194906 2016-12-01T18:39:17.80172 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:39:17.80174 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:39:17.82488 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:39:17.82500 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:39:17.82512 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:39:17.82524 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:39:17.82622 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:39:17.82623 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:39:17.82624 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:39:17.82625 0.03121747] 2016-12-01T18:39:17.82638 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:39:17.82648 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:39:17.82658 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:39:17.82669 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:39:17.83300 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:39:17.84145 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:39:17.84193 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:39:24.84338 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:39:24.85569 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6610035389 2016-12-01T18:39:24.85968 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6610035389 2016-12-01T18:39:24.91574 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:39:24.91576 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:39:24.95322 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:39:24.95328 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:39:24.95335 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:39:24.95342 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:39:24.95398 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:39:24.95399 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:39:24.95400 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:39:24.95400 0.03121747] 2016-12-01T18:39:24.95406 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:39:24.95412 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:39:24.95418 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:39:24.95425 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:39:24.95518 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:39:24.95595 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:39:24.95627 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:39:31.95836 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:39:32.01755 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6577060759 2016-12-01T18:39:32.01846 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6577060759 2016-12-01T18:39:32.07964 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:39:32.07978 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:39:32.10792 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:39:32.10794 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:39:32.10795 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:39:32.10795 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:39:32.10796 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:39:32.10798 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:39:32.10798 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:39:32.10799 0.03121747] 2016-12-01T18:39:32.10799 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:39:32.10800 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:39:32.10800 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:39:32.10801 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:39:32.10921 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:39:32.10984 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:39:32.11021 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:39:39.11045 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:39:39.15031 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6612953998 2016-12-01T18:39:39.15487 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6612953998 2016-12-01T18:39:39.21187 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:39:39.21202 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:39:39.27967 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:39:39.27973 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:39:39.27980 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:39:39.27987 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:39:39.28065 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:39:39.28066 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:39:39.28067 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:39:39.28068 0.03121747] 2016-12-01T18:39:39.28080 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:39:39.28090 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:39:39.28101 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:39:39.28112 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:39:39.28345 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:39:39.28417 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:39:39.28522 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:39:46.28686 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:39:46.32419 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.658924317 2016-12-01T18:39:46.32460 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.658924317 2016-12-01T18:39:46.38724 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:39:46.38741 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:39:46.42488 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:39:46.42501 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:39:46.42514 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:39:46.42527 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:39:46.42623 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:39:46.42624 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:39:46.42624 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:39:46.42625 0.03121747] 2016-12-01T18:39:46.42637 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:39:46.42647 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:39:46.42658 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:39:46.42665 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:39:46.43023 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:39:46.43089 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:39:46.43122 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:39:53.43135 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:39:53.49356 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6564013004 2016-12-01T18:39:53.49418 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6564013004 2016-12-01T18:39:53.55810 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:39:53.55812 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:39:53.74538 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:39:53.74540 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:39:53.74541 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:39:53.74541 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:39:53.74541 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:39:53.74542 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:39:53.74542 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:39:53.74542 0.03121747] 2016-12-01T18:39:53.74543 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:39:53.74543 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:39:53.74543 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:39:53.74544 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:39:53.74630 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:39:53.74704 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:39:53.74749 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:40:00.75502 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:40:00.78768 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6568368498 2016-12-01T18:40:00.78976 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6568368498 2016-12-01T18:40:00.85170 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:40:00.85207 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:40:00.87808 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:40:00.87815 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:40:00.87825 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:40:00.87934 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:40:00.87935 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:40:00.87936 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:40:00.87936 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:40:00.87937 0.03121747] 2016-12-01T18:40:00.87938 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:40:00.87943 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:40:00.87951 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:40:00.87962 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:40:00.88791 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:40:00.89071 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:40:00.89132 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:40:07.89170 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:40:07.93895 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6515556286 2016-12-01T18:40:07.94045 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6515556286 2016-12-01T18:40:08.00249 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:40:08.00252 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:40:08.02344 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:40:08.02347 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:40:08.02348 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:40:08.02504 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:40:08.02505 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:40:08.02505 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:40:08.02506 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:40:08.02506 0.03121747] 2016-12-01T18:40:08.02507 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:40:08.02507 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:40:08.02508 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:40:08.02508 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:40:08.03759 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:40:08.04150 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:40:08.04452 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:40:15.04256 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:40:15.08148 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6572686675 2016-12-01T18:40:15.08309 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6572686675 2016-12-01T18:40:15.14061 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:40:15.14063 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:40:15.18398 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:40:15.18400 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:40:15.18400 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:40:15.18401 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:40:15.18401 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:40:15.18402 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:40:15.18402 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:40:15.18403 0.03121747] 2016-12-01T18:40:15.18403 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:40:15.18404 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:40:15.18404 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:40:15.18405 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:40:15.18532 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:40:15.18745 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:40:15.18746 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:40:22.18885 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:40:22.25489 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.657996946 2016-12-01T18:40:22.25546 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.657996946 2016-12-01T18:40:22.31458 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:40:22.31460 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:40:22.34266 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:40:22.34272 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:40:22.34280 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:40:22.34287 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:40:22.34346 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:40:22.34347 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:40:22.34348 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:40:22.34348 0.03121747] 2016-12-01T18:40:22.34354 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:40:22.34360 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:40:22.34367 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:40:22.34374 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:40:22.34500 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:40:22.34606 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:40:22.34637 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:40:29.34694 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:40:29.37077 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6573747203 2016-12-01T18:40:29.37197 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6573747203 2016-12-01T18:40:29.43132 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:40:29.43135 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:40:29.46322 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:40:29.46330 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:40:29.46430 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:40:29.46431 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:40:29.46431 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:40:29.46432 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:40:29.46432 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:40:29.46432 0.03121747] 2016-12-01T18:40:29.46433 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:40:29.46433 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:40:29.46433 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:40:29.46434 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:40:29.46738 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:40:29.47267 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:40:29.47301 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:40:36.47449 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:40:36.53598 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6653419451 2016-12-01T18:40:36.53672 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6653419451 2016-12-01T18:40:36.59940 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:40:36.59961 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:40:36.63262 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:40:36.63275 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:40:36.63287 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:40:36.63298 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:40:36.63391 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:40:36.63392 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:40:36.63393 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:40:36.63393 0.03121747] 2016-12-01T18:40:36.63405 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:40:36.63416 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:40:36.63427 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:40:36.63438 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:40:36.63664 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:40:36.63728 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:40:36.63763 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:40:43.63787 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:40:43.64793 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6557270602 2016-12-01T18:40:43.64921 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6557270602 2016-12-01T18:40:43.70928 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:40:43.70944 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:40:43.73474 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:40:43.73481 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:40:43.73492 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:40:43.73501 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:40:43.73599 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:40:43.73600 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:40:43.73600 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:40:43.73601 0.03121747] 2016-12-01T18:40:43.73613 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:40:43.73623 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:40:43.73633 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:40:43.73644 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:40:43.74281 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:40:43.74817 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:40:43.74866 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:40:50.74903 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:40:50.75566 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.659240146 2016-12-01T18:40:50.75964 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.659240146 2016-12-01T18:40:50.81838 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:40:50.81867 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:40:50.85346 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:40:50.85348 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:40:50.85349 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:40:50.85349 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:40:50.85350 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:40:50.85350 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:40:50.85351 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:40:50.85352 0.03121747] 2016-12-01T18:40:50.85352 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:40:50.85353 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:40:50.85353 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:40:50.85354 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:40:50.86130 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:40:50.86841 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:40:50.87054 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:40:57.86890 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:40:57.92748 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6608322739 2016-12-01T18:40:57.92853 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6608322739 2016-12-01T18:40:57.99254 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:40:57.99257 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:40:58.03241 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:40:58.03244 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:40:58.03244 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:40:58.03245 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:40:58.03245 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:40:58.03246 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:40:58.03246 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:40:58.03247 0.03121747] 2016-12-01T18:40:58.03247 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:40:58.03248 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:40:58.03248 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:40:58.03249 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:40:58.03558 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:40:58.04220 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:40:58.04264 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:41:05.04406 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:41:05.09719 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6629960413 2016-12-01T18:41:05.10353 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6629960413 2016-12-01T18:41:05.16229 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:41:05.16249 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:41:05.19206 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:41:05.19213 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:41:05.19222 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:41:05.19231 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:41:05.19325 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:41:05.19326 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:41:05.19327 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:41:05.19327 0.03121747] 2016-12-01T18:41:05.19335 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:41:05.19345 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:41:05.19357 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:41:05.19367 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:41:05.20401 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:41:05.20575 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:41:05.20624 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:41:12.20662 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:41:12.26097 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6630501445 2016-12-01T18:41:12.26190 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6630501445 2016-12-01T18:41:12.32251 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:41:12.32329 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:41:12.36156 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:41:12.36158 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:41:12.36159 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:41:12.36160 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:41:12.36160 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:41:12.36161 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:41:12.36161 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:41:12.36161 0.03121747] 2016-12-01T18:41:12.36162 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:41:12.36162 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:41:12.36163 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:41:12.36163 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:41:12.36746 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:41:12.36890 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:41:12.36942 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:41:19.37074 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:41:19.43297 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6598601595 2016-12-01T18:41:19.43362 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6598601595 2016-12-01T18:41:19.49998 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:41:19.50001 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:41:19.52992 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:41:19.52994 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:41:19.52994 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:41:19.52995 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:41:19.52995 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:41:19.52996 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:41:19.52997 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:41:19.52998 0.03121747] 2016-12-01T18:41:19.52998 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:41:19.52999 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:41:19.53000 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:41:19.53001 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:41:19.53096 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:41:19.53157 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:41:19.53381 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:41:26.53610 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:41:26.54699 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6583237069 2016-12-01T18:41:26.54757 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6583237069 2016-12-01T18:41:26.61258 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:41:26.61261 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:41:26.64613 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:41:26.64624 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:41:26.64636 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:41:26.64648 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:41:26.64745 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:41:26.64746 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:41:26.64746 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:41:26.64747 0.03121747] 2016-12-01T18:41:26.64759 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:41:26.64769 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:41:26.64780 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:41:26.64791 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:41:26.65037 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:41:26.65098 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:41:26.65523 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:41:33.65948 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:41:33.71479 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6578446778 2016-12-01T18:41:33.71591 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6578446778 2016-12-01T18:41:33.78944 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:41:33.78947 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:41:33.82640 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:41:33.82643 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:41:33.82643 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:41:33.82644 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:41:33.82646 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:41:33.82646 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:41:33.82647 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:41:33.82648 0.03121747] 2016-12-01T18:41:33.82648 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:41:33.82648 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:41:33.82649 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:41:33.82649 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:41:33.82849 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:41:33.82906 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:41:33.82937 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:41:40.82969 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:41:40.83663 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6602821585 2016-12-01T18:41:40.83721 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6602821585 2016-12-01T18:41:40.89759 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:41:40.89775 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:41:40.93548 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:41:40.93551 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:41:40.93551 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:41:40.93552 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:41:40.93552 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:41:40.93553 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:41:40.93553 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:41:40.93554 0.03121747] 2016-12-01T18:41:40.93554 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:41:40.93555 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:41:40.93555 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:41:40.93556 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:41:40.93899 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:41:40.94071 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:41:40.94104 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:41:47.94150 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:41:47.99485 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6657494705 2016-12-01T18:41:47.99672 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6657494705 2016-12-01T18:41:48.06150 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:41:48.06162 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:41:48.44573 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:41:48.44577 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:41:48.44577 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:41:48.44578 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:41:48.44615 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:41:48.44616 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:41:48.44617 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:41:48.44617 0.03121747] 2016-12-01T18:41:48.44624 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:41:48.45342 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:41:48.45344 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:41:48.45345 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:41:48.45345 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:41:48.45349 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:41:48.45349 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:41:55.44928 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:41:55.46953 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6580310195 2016-12-01T18:41:55.47064 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6580310195 2016-12-01T18:41:55.53211 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:41:55.53249 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:41:55.55947 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:41:55.55949 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:41:55.55950 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:41:55.55950 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:41:55.55951 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:41:55.55951 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:41:55.55952 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:41:55.55952 0.03121747] 2016-12-01T18:41:55.55953 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:41:55.55954 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:41:55.55978 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:41:55.55979 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:41:55.56115 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:41:55.56168 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:41:55.56208 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:42:02.56243 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:42:02.57180 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6584415924 2016-12-01T18:42:02.57216 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6584415924 2016-12-01T18:42:02.63520 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:42:02.63537 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:42:02.66014 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:42:02.66016 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:42:02.66017 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:42:02.66017 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:42:02.67174 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:42:02.67175 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:42:02.67176 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:42:02.67176 0.03121747] 2016-12-01T18:42:02.67177 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:42:02.67177 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:42:02.67178 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:42:02.67178 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:42:02.67984 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:42:02.69604 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:42:02.69654 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:42:09.69688 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:42:09.73268 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6697329522 2016-12-01T18:42:09.73345 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6697329522 2016-12-01T18:42:09.79746 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:42:09.79748 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:42:09.83837 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:42:09.83848 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:42:09.83856 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:42:09.83864 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:42:09.83928 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:42:09.83930 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:42:09.83930 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:42:09.83931 0.03121747] 2016-12-01T18:42:09.83931 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:42:09.83936 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:42:09.83944 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:42:09.83955 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:42:09.84334 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:42:09.84387 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:42:09.84411 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:42:16.84434 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:42:16.89073 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6622520667 2016-12-01T18:42:16.89158 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6622520667 2016-12-01T18:42:16.95421 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:42:16.95434 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:42:16.99341 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:42:16.99353 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:42:16.99365 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:42:16.99377 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:42:16.99869 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:42:16.99871 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:42:16.99872 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:42:16.99872 0.03121747] 2016-12-01T18:42:16.99889 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:42:16.99899 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:42:16.99909 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:42:16.99920 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:42:17.00125 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:42:17.00408 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:42:17.00465 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:42:24.00596 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:42:24.06599 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6623572542 2016-12-01T18:42:24.06646 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6623572542 2016-12-01T18:42:24.12920 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:42:24.12922 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:42:24.16133 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:42:24.16135 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:42:24.16135 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:42:24.16136 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:42:24.16199 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:42:24.16200 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:42:24.16201 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:42:24.16201 0.03121747] 2016-12-01T18:42:24.16202 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:42:24.16202 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:42:24.16203 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:42:24.16203 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:42:24.16290 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:42:24.16355 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:42:24.16491 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:42:31.16573 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:42:31.17961 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6639723622 2016-12-01T18:42:31.18232 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6639723622 2016-12-01T18:42:31.24260 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:42:31.24291 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:42:31.28256 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:42:31.28258 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:42:31.28259 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:42:31.28259 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:42:31.28260 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:42:31.28260 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:42:31.28261 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:42:31.28262 0.03121747] 2016-12-01T18:42:31.28262 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:42:31.28262 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:42:31.28263 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:42:31.28263 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:42:31.28617 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:42:31.28676 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:42:31.28868 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:42:38.28974 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:42:38.34680 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6613203085 2016-12-01T18:42:38.34990 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6613203085 2016-12-01T18:42:38.41206 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:42:38.41209 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:42:38.48547 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:42:38.48553 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:42:38.48560 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:42:38.48567 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:42:38.48649 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:42:38.48651 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:42:38.48651 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:42:38.48652 0.03121747] 2016-12-01T18:42:38.48652 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:42:38.48652 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:42:38.48653 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:42:38.48653 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:42:38.49317 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:42:38.49383 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:42:38.49414 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:42:45.49417 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:42:45.52973 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6700894424 2016-12-01T18:42:45.53608 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6700894424 2016-12-01T18:42:45.59306 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:42:45.59308 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:42:45.63424 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:42:45.63426 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:42:45.63426 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:42:45.63427 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:42:45.63533 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:42:45.63534 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:42:45.63534 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:42:45.63535 0.03121747] 2016-12-01T18:42:45.63535 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:42:45.63536 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:42:45.63536 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:42:45.63539 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:42:45.63657 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:42:45.63779 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:42:45.63835 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:42:52.63874 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:42:52.64995 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6628172911 2016-12-01T18:42:52.65923 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6628172911 2016-12-01T18:42:52.70972 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:42:52.70974 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:42:52.74463 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:42:52.74465 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:42:52.74466 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:42:52.74467 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:42:52.74467 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:42:52.74468 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:42:52.74468 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:42:52.74469 0.03121747] 2016-12-01T18:42:52.74469 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:42:52.74469 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:42:52.74470 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:42:52.74470 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:42:52.75299 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:42:52.75788 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:42:52.75837 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:42:59.75835 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:42:59.81514 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6674337537 2016-12-01T18:42:59.81567 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6674337537 2016-12-01T18:42:59.87858 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:42:59.87878 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:42:59.90576 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:42:59.90585 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:42:59.90593 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:42:59.90600 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:42:59.90654 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:42:59.90655 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:42:59.90655 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:42:59.90656 0.03121747] 2016-12-01T18:42:59.90662 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:42:59.90667 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:42:59.90674 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:42:59.90680 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:42:59.90794 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:42:59.91042 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:42:59.91205 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:43:06.91414 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:43:06.92464 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6609192464 2016-12-01T18:43:06.92780 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6609192464 2016-12-01T18:43:06.98690 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:43:06.98721 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:43:07.01794 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:43:07.01796 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:43:07.01796 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:43:07.01797 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:43:07.01797 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:43:07.01798 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:43:07.01798 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:43:07.01798 0.03121747] 2016-12-01T18:43:07.01800 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:43:07.01801 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:43:07.01809 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:43:07.01817 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:43:07.02370 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:43:07.02527 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:43:07.02763 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:43:14.02816 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:43:14.08930 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6643748529 2016-12-01T18:43:14.09367 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6643748529 2016-12-01T18:43:14.15600 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:43:14.15664 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:43:14.18801 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:43:14.18813 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:43:14.18825 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:43:14.18836 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:43:14.18933 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:43:14.18934 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:43:14.18935 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:43:14.18935 0.03121747] 2016-12-01T18:43:14.18947 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:43:14.18957 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:43:14.18968 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:43:14.18979 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:43:14.19161 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:43:14.19217 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:43:14.19246 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:43:21.19276 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:43:21.20018 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6601677706 2016-12-01T18:43:21.20319 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6601677706 2016-12-01T18:43:21.26898 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:43:21.26901 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:43:21.30850 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:43:21.30852 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:43:21.30852 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:43:21.30853 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:43:21.30915 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:43:21.30918 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:43:21.30918 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:43:21.30919 0.03121747] 2016-12-01T18:43:21.30919 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:43:21.30920 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:43:21.30920 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:43:21.30921 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:43:21.31152 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:43:21.31217 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:43:21.31251 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:43:28.31350 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:43:28.36624 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6661034097 2016-12-01T18:43:28.36695 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6661034097 2016-12-01T18:43:28.42944 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:43:28.43071 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:43:28.45187 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:43:28.45193 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:43:28.45201 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:43:28.45207 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:43:28.45343 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:43:28.45344 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:43:28.45345 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:43:28.45345 0.03121747] 2016-12-01T18:43:28.45346 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:43:28.45346 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:43:28.45347 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:43:28.45347 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:43:28.46166 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:43:28.47111 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:43:28.47331 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:43:35.47294 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:43:35.53362 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6591405217 2016-12-01T18:43:35.53436 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6591405217 2016-12-01T18:43:35.59623 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:43:35.59626 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:43:35.64522 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:43:35.64525 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:43:35.64525 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:43:35.64527 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:43:35.64527 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:43:35.64528 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:43:35.64528 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:43:35.64529 0.03121747] 2016-12-01T18:43:35.64529 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:43:35.64530 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:43:35.64530 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:43:35.64531 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:43:35.64628 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:43:35.64768 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:43:35.64797 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:43:42.64846 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:43:42.70793 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6609521573 2016-12-01T18:43:42.70844 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6609521573 2016-12-01T18:43:42.77852 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:43:42.77854 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:43:42.80898 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:43:42.80900 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:43:42.80900 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:43:42.80901 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:43:42.80974 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:43:42.80975 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:43:42.80976 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:43:42.80977 0.03121747] 2016-12-01T18:43:42.80977 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:43:42.80978 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:43:42.80978 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:43:42.80978 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:43:42.81092 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:43:42.81173 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:43:42.81205 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:43:49.81524 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:43:49.87150 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6587245602 2016-12-01T18:43:49.87257 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6587245602 2016-12-01T18:43:49.93377 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:43:49.93379 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:43:49.96287 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:43:49.96293 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:43:49.96300 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:43:49.96307 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:43:49.96437 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:43:49.96438 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:43:49.96439 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:43:49.96440 0.03121747] 2016-12-01T18:43:49.96440 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:43:49.96441 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:43:49.96441 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:43:49.96442 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:43:49.96937 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:43:49.97005 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:43:49.97018 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:43:56.97040 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:43:56.97802 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6524951615 2016-12-01T18:43:56.97862 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6524951615 2016-12-01T18:43:57.04209 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:43:57.04212 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:43:57.07749 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:43:57.07756 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:43:57.07764 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:43:57.07771 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:43:57.07828 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:43:57.07829 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:43:57.07829 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:43:57.07830 0.03121747] 2016-12-01T18:43:57.07836 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:43:57.07841 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:43:57.07848 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:43:57.07854 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:43:57.07987 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:43:57.08040 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:43:57.08064 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:44:04.08079 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:44:04.13631 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6608962299 2016-12-01T18:44:04.13835 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6608962299 2016-12-01T18:44:04.20029 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:44:04.20057 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:44:04.22536 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:44:04.22543 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:44:04.22551 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:44:04.22558 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:44:04.22639 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:44:04.22640 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:44:04.22640 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:44:04.22641 0.03121747] 2016-12-01T18:44:04.22653 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:44:04.22663 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:44:04.22674 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:44:04.22688 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:44:04.22813 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:44:04.22921 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:44:04.22967 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:44:11.23011 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:44:11.24862 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6570437199 2016-12-01T18:44:11.25259 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6570437199 2016-12-01T18:44:11.31127 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:44:11.31128 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:44:11.33864 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:44:11.33867 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:44:11.33867 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:44:11.33868 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:44:11.33868 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:44:11.33869 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:44:11.33869 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:44:11.33870 0.03121747] 2016-12-01T18:44:11.33870 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:44:11.33870 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:44:11.33871 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:44:11.33871 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:44:11.33975 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:44:11.34039 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:44:11.34085 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:44:18.34167 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:44:18.34881 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6548367805 2016-12-01T18:44:18.35009 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6548367805 2016-12-01T18:44:18.40978 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:44:18.40981 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:44:18.79945 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:44:18.79947 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:44:18.79948 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:44:18.79949 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:44:18.80000 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:44:18.80001 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:44:18.80001 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:44:18.80002 0.03121747] 2016-12-01T18:44:18.80002 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:44:18.80003 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:44:18.80003 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:44:18.80004 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:44:18.80420 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:44:18.80826 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:44:18.80875 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:44:25.80931 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:44:25.82645 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6565120262 2016-12-01T18:44:25.82930 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6565120262 2016-12-01T18:44:25.88834 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:44:25.88836 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:44:25.91937 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:44:25.91939 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:44:25.91939 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:44:25.91940 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:44:25.92026 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:44:25.92028 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:44:25.92028 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:44:25.92029 0.03121747] 2016-12-01T18:44:25.92029 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:44:25.92030 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:44:25.92030 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:44:25.92031 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:44:25.92255 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:44:25.92322 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:44:25.92361 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:44:32.92488 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:44:32.93282 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6530664935 2016-12-01T18:44:32.93349 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6530664935 2016-12-01T18:44:32.99879 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:44:32.99882 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:44:33.02646 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:44:33.02648 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:44:33.02649 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:44:33.02649 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:44:33.02650 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:44:33.02650 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:44:33.02651 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:44:33.02651 0.03121747] 2016-12-01T18:44:33.02652 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:44:33.02652 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:44:33.02652 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:44:33.02653 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:44:33.02931 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:44:33.02996 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:44:33.03049 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:44:40.03083 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:44:40.03567 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6497109016 2016-12-01T18:44:40.03672 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6497109016 2016-12-01T18:44:40.09928 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:44:40.09930 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:44:40.13046 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:44:40.13048 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:44:40.13048 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:44:40.13049 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:44:40.13049 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:44:40.13050 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:44:40.13050 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:44:40.13051 0.03121747] 2016-12-01T18:44:40.13051 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:44:40.13052 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:44:40.13052 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:44:40.13053 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:44:40.13740 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:44:40.13818 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:44:40.13865 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:44:47.13888 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:44:47.13978 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6699961612 2016-12-01T18:44:47.14093 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6699961612 2016-12-01T18:44:47.20238 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:44:47.20256 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:44:47.22905 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:44:47.22912 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:44:47.22921 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:44:47.22928 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:44:47.23054 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:44:47.23055 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:44:47.23055 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:44:47.23055 0.03121747] 2016-12-01T18:44:47.23056 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:44:47.23056 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:44:47.23056 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:44:47.23057 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:44:47.23148 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:44:47.23266 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:44:47.23296 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:44:54.23347 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:44:54.24593 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6617809926 2016-12-01T18:44:54.24660 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6617809926 2016-12-01T18:44:54.30635 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:44:54.30637 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:44:54.35105 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:44:54.35107 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:44:54.35107 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:44:54.35108 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:44:54.35108 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:44:54.35109 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:44:54.35109 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:44:54.35110 0.03121747] 2016-12-01T18:44:54.35110 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:44:54.35111 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:44:54.35113 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:44:54.35125 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:44:54.36012 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:44:54.36168 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:44:54.36216 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:45:01.36461 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:45:01.42275 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.65966075 2016-12-01T18:45:01.43092 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.65966075 2016-12-01T18:45:01.48269 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:45:01.48272 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:45:01.50653 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:45:01.50663 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:45:01.50673 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:45:01.50682 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:45:01.50845 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:45:01.50847 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:45:01.50847 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:45:01.50848 0.03121747] 2016-12-01T18:45:01.50848 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:45:01.50849 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:45:01.50849 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:45:01.50850 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:45:01.51704 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:45:01.52176 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:45:01.52223 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:45:08.52293 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:45:08.53981 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6574292855 2016-12-01T18:45:08.54349 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6574292855 2016-12-01T18:45:08.60585 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:45:08.60588 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:45:08.65142 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:45:08.65144 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:45:08.65145 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:45:08.65155 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:45:08.65335 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:45:08.65337 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:45:08.65337 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:45:08.65340 0.03121747] 2016-12-01T18:45:08.65340 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:45:08.65341 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:45:08.65341 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:45:08.65342 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:45:08.65641 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:45:08.66347 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:45:08.66556 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:45:15.66856 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:45:15.68328 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6595544325 2016-12-01T18:45:15.68330 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6595544325 2016-12-01T18:45:15.74044 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:45:15.74046 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:45:15.77896 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:45:15.77898 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:45:15.77899 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:45:15.77899 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:45:15.77900 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:45:15.77900 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:45:15.77901 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:45:15.77901 0.03121747] 2016-12-01T18:45:15.77902 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:45:15.77902 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:45:15.77903 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:45:15.77903 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:45:15.78050 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:45:15.79105 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:45:15.79138 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:45:22.79611 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:45:22.84419 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6645104321 2016-12-01T18:45:22.84496 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6645104321 2016-12-01T18:45:22.90696 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:45:22.90706 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:45:22.93955 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:45:22.93957 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:45:22.93958 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:45:22.93958 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:45:22.93960 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:45:22.93961 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:45:22.93961 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:45:22.93962 0.03121747] 2016-12-01T18:45:22.93962 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:45:22.93962 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:45:22.93963 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:45:22.93963 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:45:22.94580 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:45:22.95049 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:45:22.95098 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:45:29.95130 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:45:30.01120 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6629644952 2016-12-01T18:45:30.01200 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6629644952 2016-12-01T18:45:30.07238 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:45:30.07250 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:45:30.09802 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:45:30.09804 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:45:30.09805 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:45:30.09805 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:45:30.09905 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:45:30.09906 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:45:30.09906 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:45:30.09907 0.03121747] 2016-12-01T18:45:30.09907 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:45:30.09908 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:45:30.09908 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:45:30.09909 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:45:30.10004 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:45:30.10074 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:45:30.10176 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:45:37.10202 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:45:37.10423 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.661186515 2016-12-01T18:45:37.10466 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.661186515 2016-12-01T18:45:37.16810 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:45:37.16832 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:45:37.20480 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:45:37.20489 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:45:37.20497 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:45:37.20512 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:45:37.20604 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:45:37.20605 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:45:37.20606 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:45:37.20606 0.03121747] 2016-12-01T18:45:37.20614 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:45:37.20622 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:45:37.20630 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:45:37.20636 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:45:37.20780 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:45:37.20990 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:45:37.21022 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:45:44.21070 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:45:44.27258 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6639383671 2016-12-01T18:45:44.27981 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6639383671 2016-12-01T18:45:44.33411 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:45:44.33421 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:45:44.35978 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:45:44.35980 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:45:44.35981 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:45:44.35981 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:45:44.35981 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:45:44.35982 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:45:44.35982 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:45:44.35982 0.03121747] 2016-12-01T18:45:44.35983 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:45:44.35983 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:45:44.35983 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:45:44.35984 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:45:44.36501 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:45:44.36811 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:45:44.36863 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:45:51.36967 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:45:51.42644 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6595114523 2016-12-01T18:45:51.42711 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6595114523 2016-12-01T18:45:51.48659 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:45:51.48691 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:45:51.51280 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:45:51.51282 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:45:51.51282 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:45:51.51283 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:45:51.51283 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:45:51.51284 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:45:51.51284 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:45:51.51285 0.03121747] 2016-12-01T18:45:51.51285 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:45:51.51286 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:45:51.51315 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:45:51.51316 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:45:51.51601 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:45:51.51876 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:45:51.51898 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:45:58.52152 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:45:58.52957 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6602973436 2016-12-01T18:45:58.53262 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6602973436 2016-12-01T18:45:58.59131 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:45:58.59134 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:45:58.63601 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:45:58.63603 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:45:58.63603 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:45:58.63604 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:45:58.63604 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:45:58.63605 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:45:58.63605 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:45:58.63606 0.03121747] 2016-12-01T18:45:58.63606 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:45:58.63607 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:45:58.63607 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:45:58.63608 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:45:58.64255 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:45:58.64910 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:45:58.64998 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:46:05.65016 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:46:05.69244 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6648338155 2016-12-01T18:46:05.69289 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6648338155 2016-12-01T18:46:05.75628 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:46:05.75631 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:46:05.79431 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:46:05.79434 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:46:05.79560 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:46:05.79561 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:46:05.79562 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:46:05.79562 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:46:05.79563 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:46:05.79564 0.03121747] 2016-12-01T18:46:05.79564 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:46:05.79565 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:46:05.79565 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:46:05.79565 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:46:05.79990 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:46:05.80049 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:46:05.80072 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:46:12.80135 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:46:12.86056 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.660016243 2016-12-01T18:46:12.86246 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.660016243 2016-12-01T18:46:12.92424 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:46:12.92427 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:46:12.95002 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:46:12.95004 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:46:12.95005 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:46:12.95006 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:46:12.95006 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:46:12.95007 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:46:12.95007 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:46:12.95008 0.03121747] 2016-12-01T18:46:12.95008 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:46:12.95009 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:46:12.95009 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:46:12.95010 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:46:12.95106 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:46:12.95171 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:46:12.95203 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:46:19.95219 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:46:19.95959 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6563466536 2016-12-01T18:46:19.96219 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6563466536 2016-12-01T18:46:20.02351 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:46:20.02372 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:46:20.05224 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:46:20.05237 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:46:20.05249 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:46:20.05260 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:46:20.05354 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:46:20.05356 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:46:20.05356 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:46:20.05357 0.03121747] 2016-12-01T18:46:20.05368 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:46:20.05378 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:46:20.05388 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:46:20.05400 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:46:20.05935 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:46:20.06057 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:46:20.06088 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:46:27.06102 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:46:27.06829 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.658053264 2016-12-01T18:46:27.06883 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.658053264 2016-12-01T18:46:27.13028 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:46:27.13068 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:46:27.16404 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:46:27.16406 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:46:27.16407 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:46:27.16407 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:46:27.16457 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:46:27.16458 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:46:27.16459 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:46:27.16459 0.03121747] 2016-12-01T18:46:27.16466 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:46:27.16476 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:46:27.16596 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:46:27.16615 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:46:27.16812 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:46:27.16870 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:46:27.16902 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:46:34.16924 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:46:34.22290 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6587741636 2016-12-01T18:46:34.22347 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6587741636 2016-12-01T18:46:34.28885 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:46:34.28896 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:46:34.32692 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:46:34.32694 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:46:34.32695 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:46:34.32695 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:46:34.33044 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:46:34.33046 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:46:34.33046 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:46:34.33047 0.03121747] 2016-12-01T18:46:34.33047 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:46:34.33048 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:46:34.33048 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:46:34.33049 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:46:34.33049 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:46:34.33049 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:46:34.33050 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:46:41.32999 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:46:41.38289 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6578810104 2016-12-01T18:46:41.38804 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6578810104 2016-12-01T18:46:41.44448 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:46:41.44473 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:46:41.47210 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:46:41.47222 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:46:41.47230 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:46:41.47236 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:46:41.47292 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:46:41.47293 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:46:41.47294 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:46:41.47294 0.03121747] 2016-12-01T18:46:41.47300 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:46:41.47307 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:46:41.47316 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:46:41.47326 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:46:41.47694 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:46:41.48045 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:46:41.48082 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:46:48.48105 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:46:48.54026 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6574367891 2016-12-01T18:46:48.54090 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6574367891 2016-12-01T18:46:48.60373 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:46:48.60417 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:46:48.65738 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:46:48.65740 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:46:48.65741 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:46:48.65741 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:46:48.65742 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:46:48.65742 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:46:48.65743 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:46:48.65743 0.03121747] 2016-12-01T18:46:48.65744 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:46:48.65744 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:46:48.65745 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:46:48.65745 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:46:48.66332 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:46:48.66648 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:46:48.66671 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:46:55.66712 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:46:55.69426 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6606790361 2016-12-01T18:46:55.69487 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6606790361 2016-12-01T18:46:55.76353 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:46:55.76356 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:46:55.79233 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:46:55.79240 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:46:55.79250 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:46:55.79258 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:46:55.79355 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:46:55.79356 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:46:55.79357 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:46:55.79357 0.03121747] 2016-12-01T18:46:55.79371 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:46:55.79381 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:46:55.79392 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:46:55.79403 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:46:55.79512 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:46:55.79577 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:46:55.79610 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:47:02.79704 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:47:02.85288 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.658677653 2016-12-01T18:47:02.85362 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.658677653 2016-12-01T18:47:02.91501 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:47:02.91514 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:47:02.94535 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:47:02.94547 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:47:02.94559 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:47:02.94570 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:47:02.94665 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:47:02.94666 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:47:02.94667 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:47:02.94668 0.03121747] 2016-12-01T18:47:02.94679 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:47:02.94689 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:47:02.94701 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:47:02.94877 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:47:02.94983 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:47:02.95046 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:47:02.95463 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:47:09.95487 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:47:10.01376 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6607545697 2016-12-01T18:47:10.01503 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6607545697 2016-12-01T18:47:10.07618 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:47:10.07640 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:47:10.11916 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:47:10.11925 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:47:10.11934 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:47:10.11942 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:47:10.12031 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:47:10.12034 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:47:10.12034 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:47:10.12035 0.03121747] 2016-12-01T18:47:10.12041 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:47:10.12048 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:47:10.12057 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:47:10.12065 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:47:10.12173 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:47:10.13161 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:47:10.13211 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:47:17.13245 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:47:17.16836 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6610383589 2016-12-01T18:47:17.17181 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6610383589 2016-12-01T18:47:17.23106 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:47:17.23127 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:47:17.27546 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:47:17.27552 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:47:17.27560 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:47:17.27566 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:47:17.27657 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:47:17.27658 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:47:17.27658 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:47:17.27659 0.03121747] 2016-12-01T18:47:17.27664 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:47:17.27674 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:47:17.27686 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:47:17.27691 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:47:17.28339 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:47:17.28541 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:47:17.28575 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:47:24.28671 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:47:24.33570 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6577482681 2016-12-01T18:47:24.33614 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6577482681 2016-12-01T18:47:24.39983 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:47:24.40007 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:47:24.43624 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:47:24.43632 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:47:24.43639 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:47:24.43645 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:47:24.43709 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:47:24.43710 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:47:24.43711 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:47:24.43711 0.03121747] 2016-12-01T18:47:24.43723 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:47:24.43733 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:47:24.43744 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:47:24.43754 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:47:24.43902 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:47:24.43966 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:47:24.43998 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:47:31.44026 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:47:31.50375 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6601909335 2016-12-01T18:47:31.50599 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6601909335 2016-12-01T18:47:31.55924 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:47:31.55952 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:47:31.57872 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:47:31.57884 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:47:31.57887 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:47:31.57895 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:47:31.57950 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:47:31.57951 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:47:31.57952 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:47:31.57952 0.03121747] 2016-12-01T18:47:31.57959 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:47:31.57965 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:47:31.57974 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:47:31.57980 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:47:31.58258 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:47:31.58882 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:47:31.58935 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:47:38.58959 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:47:38.59622 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6585305551 2016-12-01T18:47:38.60017 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6585305551 2016-12-01T18:47:38.66004 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:47:38.66006 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:47:38.71505 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:47:38.71517 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:47:38.71531 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:47:38.71543 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:47:38.71892 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:47:38.71893 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:47:38.71893 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:47:38.71894 0.03121747] 2016-12-01T18:47:38.71894 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:47:38.71895 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:47:38.71895 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:47:38.71896 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:47:38.71896 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:47:38.71897 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:47:38.71897 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:47:45.71911 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:47:45.75896 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6608706227 2016-12-01T18:47:45.76470 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6608706227 2016-12-01T18:47:45.82126 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:47:45.82141 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:47:45.85675 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:47:45.85686 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:47:45.85698 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:47:45.85709 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:47:45.85802 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:47:45.85803 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:47:45.85803 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:47:45.85804 0.03121747] 2016-12-01T18:47:45.85816 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:47:45.85825 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:47:45.85836 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:47:45.85846 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:47:45.86089 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:47:45.86425 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:47:45.86447 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:47:52.86525 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:47:52.91670 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6639440473 2016-12-01T18:47:52.92317 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6639440473 2016-12-01T18:47:52.98277 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:47:52.98298 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:47:53.01225 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:47:53.01237 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:47:53.01250 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:47:53.01262 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:47:53.01367 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:47:53.01368 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:47:53.01369 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:47:53.01369 0.03121747] 2016-12-01T18:47:53.01382 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:47:53.01394 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:47:53.01406 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:47:53.01418 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:47:53.01544 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:47:53.01627 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:47:53.02227 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:48:00.02245 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:48:00.02713 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6599154262 2016-12-01T18:48:00.02791 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6599154262 2016-12-01T18:48:00.09068 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:48:00.09070 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:48:00.11983 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:48:00.11986 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:48:00.11986 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:48:00.11987 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:48:00.11988 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:48:00.11988 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:48:00.11989 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:48:00.11989 0.03121747] 2016-12-01T18:48:00.11990 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:48:00.11990 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:48:00.11991 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:48:00.11991 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:48:00.12887 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:48:00.13735 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:48:00.13785 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:48:07.13936 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:48:07.19952 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6621494811 2016-12-01T18:48:07.20636 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6621494811 2016-12-01T18:48:07.26209 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:48:07.26230 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:48:07.29107 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:48:07.29119 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:48:07.29134 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:48:07.29145 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:48:07.29241 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:48:07.29242 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:48:07.29242 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:48:07.29243 0.03121747] 2016-12-01T18:48:07.29254 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:48:07.29264 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:48:07.29275 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:48:07.29285 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:48:07.29941 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:48:07.30344 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:48:07.30377 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:48:14.30389 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:48:14.35881 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6589184943 2016-12-01T18:48:14.35990 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6589184943 2016-12-01T18:48:14.42258 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:48:14.42260 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:48:14.45515 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:48:14.45527 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:48:14.45535 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:48:14.45544 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:48:14.45633 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:48:14.45634 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:48:14.45635 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:48:14.45635 0.03121747] 2016-12-01T18:48:14.45647 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:48:14.45657 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:48:14.45668 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:48:14.45679 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:48:14.46195 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:48:14.46285 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:48:14.46318 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:48:21.46345 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:48:21.51352 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6609175158 2016-12-01T18:48:21.51507 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6609175158 2016-12-01T18:48:21.57996 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:48:21.58010 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:48:21.61530 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:48:21.61532 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:48:21.61533 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:48:21.61534 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:48:21.61534 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:48:21.61534 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:48:21.61535 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:48:21.61535 0.03121747] 2016-12-01T18:48:21.61536 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:48:21.61536 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:48:21.61537 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:48:21.61537 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:48:21.62094 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:48:21.62325 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:48:21.62358 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:48:28.62513 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:48:28.67587 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6666862994 2016-12-01T18:48:28.67630 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6666862994 2016-12-01T18:48:28.73997 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:48:28.74018 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:48:28.88181 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:48:28.88184 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:48:28.88185 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:48:28.88185 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:48:28.88185 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:48:28.88186 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:48:28.88186 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:48:28.88186 0.03121747] 2016-12-01T18:48:28.88187 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:48:28.88187 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:48:28.88187 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:48:28.88188 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:48:28.89499 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:48:28.89985 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:48:28.90095 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:48:35.90165 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:48:35.95765 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6630168023 2016-12-01T18:48:35.96060 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6630168023 2016-12-01T18:48:36.02103 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:48:36.02112 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:48:36.05726 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:48:36.05728 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:48:36.05729 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:48:36.05730 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:48:36.05841 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:48:36.05843 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:48:36.05843 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:48:36.05844 0.03121747] 2016-12-01T18:48:36.05844 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:48:36.05845 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:48:36.05868 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:48:36.05870 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:48:36.06396 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:48:36.07153 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:48:36.07179 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:48:43.07200 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:48:43.11200 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6620230347 2016-12-01T18:48:43.11291 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6620230347 2016-12-01T18:48:43.17470 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:48:43.17480 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:48:43.25486 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:48:43.25488 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:48:43.25489 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:48:43.25490 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:48:43.25658 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:48:43.25660 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:48:43.25660 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:48:43.25661 0.03121747] 2016-12-01T18:48:43.25661 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:48:43.25662 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:48:43.25664 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:48:43.25664 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:48:43.25836 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:48:43.26187 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:48:43.26259 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:48:50.26490 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:48:50.26884 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6644420155 2016-12-01T18:48:50.27122 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6644420155 2016-12-01T18:48:50.33295 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:48:50.33298 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:48:50.35747 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:48:50.35753 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:48:50.35761 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:48:50.35768 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:48:50.35823 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:48:50.35824 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:48:50.35825 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:48:50.35825 0.03121747] 2016-12-01T18:48:50.35832 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:48:50.35838 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:48:50.35845 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:48:50.35851 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:48:50.35947 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:48:50.36535 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:48:50.36606 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:48:57.36780 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:48:57.42491 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6592760278 2016-12-01T18:48:57.42930 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6592760278 2016-12-01T18:48:57.49038 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:48:57.49041 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:48:57.53952 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:48:57.53954 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:48:57.53955 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:48:57.53955 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:48:57.53956 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:48:57.53956 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:48:57.53957 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:48:57.53959 0.03121747] 2016-12-01T18:48:57.53959 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:48:57.53960 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:48:57.53960 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:48:57.53961 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:48:57.54190 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:48:57.54853 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:48:57.54891 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:49:04.54907 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:49:04.58238 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6588068918 2016-12-01T18:49:04.58288 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6588068918 2016-12-01T18:49:04.64651 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:49:04.64653 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:49:04.67970 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:49:04.67973 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:49:04.67973 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:49:04.67974 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:49:04.67974 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:49:04.67974 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:49:04.67975 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:49:04.67975 0.03121747] 2016-12-01T18:49:04.67976 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:49:04.67976 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:49:04.67977 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:49:04.67977 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:49:04.68190 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:49:04.68747 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:49:04.68890 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:49:11.68914 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:49:11.73539 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6542537244 2016-12-01T18:49:11.74250 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6542537244 2016-12-01T18:49:11.79856 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:49:11.79858 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:49:12.05256 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:49:12.05259 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:49:12.05259 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:49:12.05260 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:49:12.05262 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:49:12.05262 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:49:12.05264 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:49:12.05264 0.03121747] 2016-12-01T18:49:12.05264 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:49:12.05265 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:49:12.05265 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:49:12.05266 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:49:12.05377 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:49:12.06191 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:49:12.06277 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:49:19.06265 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:49:19.07703 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6550432894 2016-12-01T18:49:19.07752 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6550432894 2016-12-01T18:49:19.13955 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:49:19.13977 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:49:19.28300 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:49:19.28312 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:49:19.28325 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:49:19.28336 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:49:19.28433 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:49:19.28434 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:49:19.28435 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:49:19.28436 0.03121747] 2016-12-01T18:49:19.28447 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:49:19.28457 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:49:19.28468 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:49:19.28479 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:49:19.28695 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:49:19.28752 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:49:19.28777 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:49:26.28798 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:49:26.29889 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6552861121 2016-12-01T18:49:26.29947 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6552861121 2016-12-01T18:49:26.36289 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:49:26.36291 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:49:26.42332 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:49:26.42335 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:49:26.42336 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:49:26.42336 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:49:26.42337 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:49:26.42337 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:49:26.42338 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:49:26.42338 0.03121747] 2016-12-01T18:49:26.42339 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:49:26.42339 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:49:26.42340 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:49:26.42340 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:49:26.42427 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:49:26.43034 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:49:26.43069 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:49:33.43099 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:49:33.45994 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6575867577 2016-12-01T18:49:33.46066 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6575867577 2016-12-01T18:49:33.52289 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:49:33.52306 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:49:33.62305 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:49:33.62317 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:49:33.62344 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:49:33.62355 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:49:33.62447 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:49:33.62448 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:49:33.62448 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:49:33.62449 0.03121747] 2016-12-01T18:49:33.62460 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:49:33.62470 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:49:33.62481 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:49:33.62491 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:49:33.62923 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:49:33.63041 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:49:33.63088 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:49:40.63123 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:49:40.68146 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6582855574 2016-12-01T18:49:40.68469 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6582855574 2016-12-01T18:49:40.74835 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:49:40.74837 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:49:40.78676 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:49:40.78686 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:49:40.78698 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:49:40.78709 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:49:40.78811 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:49:40.78812 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:49:40.78813 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:49:40.78813 0.03121747] 2016-12-01T18:49:40.78825 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:49:40.78835 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:49:40.78846 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:49:40.78857 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:49:40.79671 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:49:40.79825 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:49:40.80221 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:49:47.80265 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:49:47.84192 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6590472402 2016-12-01T18:49:47.84281 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6590472402 2016-12-01T18:49:47.90634 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:49:47.90637 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:49:47.94554 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:49:47.94556 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:49:47.94557 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:49:47.94558 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:49:47.94558 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:49:47.94559 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:49:47.94559 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:49:47.94560 0.03121747] 2016-12-01T18:49:47.94560 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:49:47.94561 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:49:47.94561 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:49:47.94562 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:49:47.94889 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:49:47.95004 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:49:47.95038 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:49:54.95058 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:49:54.99828 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6560914137 2016-12-01T18:49:54.99878 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6560914137 2016-12-01T18:49:55.06027 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:49:55.06049 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:49:55.11653 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:49:55.11666 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:49:55.11679 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:49:55.11691 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:49:55.11793 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:49:55.11794 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:49:55.11795 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:49:55.11795 0.03121747] 2016-12-01T18:49:55.11808 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:49:55.11818 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:49:55.11829 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:49:55.11843 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:49:55.11951 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:49:55.12016 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:49:55.12047 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:50:02.12433 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:50:02.16498 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6570862036 2016-12-01T18:50:02.16567 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6570862036 2016-12-01T18:50:02.22893 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:50:02.22895 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:50:02.28737 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:50:02.28739 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:50:02.28740 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:50:02.28740 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:50:02.28741 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:50:02.28741 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:50:02.28742 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:50:02.28742 0.03121747] 2016-12-01T18:50:02.28743 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:50:02.28743 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:50:02.28744 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:50:02.28744 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:50:02.28951 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:50:02.29017 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:50:02.29052 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:50:09.29338 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:50:09.35154 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.656182255 2016-12-01T18:50:09.35473 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.656182255 2016-12-01T18:50:09.41469 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:50:09.41471 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:50:09.52442 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:50:09.52444 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:50:09.52445 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:50:09.52445 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:50:09.52446 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:50:09.52447 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:50:09.52447 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:50:09.52448 0.03121747] 2016-12-01T18:50:09.52448 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:50:09.52448 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:50:09.52449 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:50:09.52449 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:50:09.53965 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:50:09.55613 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:50:09.55685 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:50:16.55683 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:50:16.59611 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6552014696 2016-12-01T18:50:16.59692 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6552014696 2016-12-01T18:50:16.66105 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:50:16.66107 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:50:16.68816 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:50:16.68819 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:50:16.68820 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:50:16.68989 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:50:16.68990 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:50:16.68991 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:50:16.68991 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:50:16.68992 0.03121747] 2016-12-01T18:50:16.68992 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:50:16.68993 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:50:16.68993 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:50:16.68994 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:50:16.69102 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:50:16.69183 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:50:16.69214 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:50:23.69238 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:50:23.69540 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.655762881 2016-12-01T18:50:23.69592 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.655762881 2016-12-01T18:50:23.76131 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:50:23.76133 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:50:23.80158 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:50:23.80159 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:50:23.80160 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:50:23.80160 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:50:23.80165 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:50:23.80166 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:50:23.80167 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:50:23.80167 0.03121747] 2016-12-01T18:50:23.80209 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:50:23.80211 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:50:23.80211 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:50:23.80212 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:50:23.81018 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:50:23.81049 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:50:23.81079 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:50:30.81163 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:50:30.85021 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.657189467 2016-12-01T18:50:30.85154 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.657189467 2016-12-01T18:50:30.91216 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:50:30.91218 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:50:30.94333 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:50:30.94340 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:50:30.94348 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:50:30.94355 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:50:30.94409 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:50:30.94410 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:50:30.94411 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:50:30.94411 0.03121747] 2016-12-01T18:50:30.94418 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:50:30.94424 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:50:30.94430 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:50:30.94437 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:50:30.94519 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:50:30.94577 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:50:30.94613 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:50:37.94631 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:50:38.00657 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6559404363 2016-12-01T18:50:38.01031 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6559404363 2016-12-01T18:50:38.06596 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:50:38.06598 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:50:38.20732 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:50:38.20735 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:50:38.20735 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:50:38.20736 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:50:38.20736 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:50:38.20737 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:50:38.20737 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:50:38.20738 0.03121747] 2016-12-01T18:50:38.20738 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:50:38.20738 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:50:38.20739 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:50:38.20739 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:50:38.21094 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:50:38.21380 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:50:38.21437 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:50:45.21459 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:50:45.22135 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6577761009 2016-12-01T18:50:45.22450 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6577761009 2016-12-01T18:50:45.28325 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:50:45.28359 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:50:45.31131 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:50:45.31133 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:50:45.31134 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:50:45.31135 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:50:45.31217 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:50:45.31218 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:50:45.31218 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:50:45.31219 0.03121747] 2016-12-01T18:50:45.31219 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:50:45.31221 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:50:45.31222 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:50:45.31222 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:50:45.31503 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:50:45.31584 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:50:45.31598 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:50:52.31619 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:50:52.37639 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6505968433 2016-12-01T18:50:52.37839 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6505968433 2016-12-01T18:50:52.43912 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:50:52.43914 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:50:52.46554 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:50:52.46556 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:50:52.46706 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:50:52.46707 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:50:52.46708 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:50:52.46708 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:50:52.46710 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:50:52.46710 0.03121747] 2016-12-01T18:50:52.46710 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:50:52.46711 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:50:52.46711 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:50:52.46712 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:50:52.47115 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:50:52.47182 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:50:52.47199 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:50:59.47208 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:50:59.53443 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6557959145 2016-12-01T18:50:59.53668 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6557959145 2016-12-01T18:50:59.59551 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:50:59.59563 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:50:59.62767 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:50:59.62779 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:50:59.62790 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:50:59.62797 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:50:59.62850 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:50:59.62853 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:50:59.62853 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:50:59.62854 0.03121747] 2016-12-01T18:50:59.62859 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:50:59.62867 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:50:59.62889 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:50:59.62890 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:50:59.64133 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:50:59.64347 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:50:59.64376 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:51:06.64409 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:51:06.69055 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6500748912 2016-12-01T18:51:06.69105 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6500748912 2016-12-01T18:51:06.75428 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:51:06.75430 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:51:06.79801 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:51:06.79803 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:51:06.79804 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:51:06.79804 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:51:06.79876 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:51:06.79877 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:51:06.79877 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:51:06.79878 0.03121747] 2016-12-01T18:51:06.79878 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:51:06.79879 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:51:06.79879 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:51:06.79880 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:51:06.80500 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:51:06.80655 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:51:06.80685 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:51:13.80732 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:51:13.84813 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6569833661 2016-12-01T18:51:13.85053 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6569833661 2016-12-01T18:51:13.91224 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:51:13.91226 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:51:13.94161 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:51:13.94165 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:51:13.94166 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:51:13.94168 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:51:13.94168 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:51:13.94169 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:51:13.94169 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:51:13.94170 0.03121747] 2016-12-01T18:51:13.94171 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:51:13.94172 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:51:13.94172 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:51:13.94173 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:51:13.94403 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:51:13.94496 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:51:13.94728 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:51:20.94539 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:51:21.00911 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6550864563 2016-12-01T18:51:21.01557 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6550864563 2016-12-01T18:51:21.07151 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:51:21.07163 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:51:21.11898 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:51:21.11900 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:51:21.11900 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:51:21.11900 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:51:21.11901 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:51:21.11901 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:51:21.11901 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:51:21.11902 0.03121747] 2016-12-01T18:51:21.11902 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:51:21.11902 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:51:21.11903 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:51:21.11903 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:51:21.11963 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:51:21.12063 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:51:21.12111 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:51:28.12138 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:51:28.17198 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6557555479 2016-12-01T18:51:28.17240 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6557555479 2016-12-01T18:51:28.23396 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:51:28.23413 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:51:28.34921 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:51:28.34933 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:51:28.34945 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:51:28.34956 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:51:28.35051 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:51:28.35052 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:51:28.35053 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:51:28.35053 0.03121747] 2016-12-01T18:51:28.35064 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:51:28.35073 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:51:28.35084 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:51:28.35095 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:51:28.35995 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:51:28.36210 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:51:28.36327 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:51:35.36432 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:51:35.39692 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6585840744 2016-12-01T18:51:35.39951 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6585840744 2016-12-01T18:51:35.45851 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:51:35.45854 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:51:35.49305 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:51:35.49307 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:51:35.49308 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:51:35.49308 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:51:35.49309 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:51:35.49310 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:51:35.49310 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:51:35.49311 0.03121747] 2016-12-01T18:51:35.49311 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:51:35.49312 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:51:35.49312 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:51:35.49313 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:51:35.50074 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:51:35.50541 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:51:35.50573 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:51:42.50626 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:51:42.54765 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6593221731 2016-12-01T18:51:42.54825 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6593221731 2016-12-01T18:51:42.61209 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:51:42.61245 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:51:42.66854 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:51:42.66857 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:51:42.66866 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:51:42.66875 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:51:42.67014 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:51:42.67015 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:51:42.67016 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:51:42.67017 0.03121747] 2016-12-01T18:51:42.67017 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:51:42.67018 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:51:42.67018 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:51:42.67018 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:51:42.67492 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:51:42.67824 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:51:42.67836 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:51:49.67858 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:51:49.71101 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6526820199 2016-12-01T18:51:49.71155 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6526820199 2016-12-01T18:51:49.77582 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:51:49.77603 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:51:49.80042 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:51:49.80054 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:51:49.80066 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:51:49.80078 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:51:49.80193 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:51:49.80194 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:51:49.80194 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:51:49.80195 0.03121747] 2016-12-01T18:51:49.80208 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:51:49.80219 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:51:49.80230 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:51:49.80241 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:51:49.80559 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:51:49.80626 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:51:49.80659 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:51:56.80681 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:51:56.81480 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.656321348 2016-12-01T18:51:56.81543 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.656321348 2016-12-01T18:51:56.87789 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:51:56.87791 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:51:56.91314 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:51:56.91316 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:51:56.91316 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:51:56.91317 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:51:56.91317 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:51:56.91318 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:51:56.91318 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:51:56.91319 0.03121747] 2016-12-01T18:51:56.91319 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:51:56.91320 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:51:56.91339 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:51:56.91340 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:51:56.91422 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:51:56.91501 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:51:56.91512 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:52:03.91565 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:52:03.92386 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6610518212 2016-12-01T18:52:03.92447 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6610518212 2016-12-01T18:52:03.99067 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:52:03.99089 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:52:04.02656 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:52:04.02668 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:52:04.02681 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:52:04.02693 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:52:04.02794 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:52:04.02796 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:52:04.02796 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:52:04.02797 0.03121747] 2016-12-01T18:52:04.02808 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:52:04.02818 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:52:04.02831 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:52:04.02842 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:52:04.03641 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:52:04.04064 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:52:04.04093 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:52:11.04119 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:52:11.08512 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6557342604 2016-12-01T18:52:11.08829 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6557342604 2016-12-01T18:52:11.14808 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:52:11.14842 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:52:11.17049 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:52:11.17051 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:52:11.17051 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:52:11.17052 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:52:11.17053 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:52:11.17055 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:52:11.17055 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:52:11.17056 0.03121747] 2016-12-01T18:52:11.17056 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:52:11.17057 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:52:11.17057 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:52:11.17058 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:52:11.17180 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:52:11.17276 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:52:11.17307 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:52:18.17330 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:52:18.18337 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6584605915 2016-12-01T18:52:18.18434 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6584605915 2016-12-01T18:52:18.24495 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:52:18.24497 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:52:18.45293 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:52:18.45295 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:52:18.45296 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:52:18.45296 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:52:18.45297 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:52:18.45297 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:52:18.45298 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:52:18.45298 0.03121747] 2016-12-01T18:52:18.45298 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:52:18.45299 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:52:18.45299 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:52:18.45300 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:52:18.45401 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:52:18.45675 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:52:18.45719 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:52:25.45743 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:52:25.46843 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6642526016 2016-12-01T18:52:25.46892 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6642526016 2016-12-01T18:52:25.53018 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:52:25.53039 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:52:25.57699 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:52:25.57711 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:52:25.57723 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:52:25.57734 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:52:25.57831 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:52:25.57832 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:52:25.57832 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:52:25.57833 0.03121747] 2016-12-01T18:52:25.57844 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:52:25.57854 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:52:25.57865 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:52:25.57876 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:52:25.58414 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:52:25.59050 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:52:25.59082 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:52:32.59125 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:52:32.63421 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.661897768 2016-12-01T18:52:32.63887 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.661897768 2016-12-01T18:52:32.69649 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:52:32.69652 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:52:32.71712 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:52:32.71877 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:52:32.71878 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:52:32.71879 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:52:32.71879 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:52:32.71880 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:52:32.71880 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:52:32.71881 0.03121747] 2016-12-01T18:52:32.71881 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:52:32.71882 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:52:32.71883 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:52:32.71884 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:52:32.72157 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:52:32.72437 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:52:32.72579 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:52:39.72626 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:52:39.73050 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6604929455 2016-12-01T18:52:39.73104 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6604929455 2016-12-01T18:52:39.79418 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:52:39.79420 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:52:39.82040 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:52:39.82046 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:52:39.82053 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:52:39.82060 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:52:39.82174 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:52:39.82175 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:52:39.82176 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:52:39.82176 0.03121747] 2016-12-01T18:52:39.82177 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:52:39.82177 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:52:39.82177 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:52:39.82178 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:52:39.82253 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:52:39.82314 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:52:39.82345 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:52:46.82356 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:52:46.84107 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6590801324 2016-12-01T18:52:46.84846 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6590801324 2016-12-01T18:52:46.90383 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:52:46.90400 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:52:46.94114 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:52:46.94126 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:52:46.94141 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:52:46.94150 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:52:46.94241 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:52:46.94242 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:52:46.94243 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:52:46.94245 0.03121747] 2016-12-01T18:52:46.94250 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:52:46.94257 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:52:46.94266 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:52:46.94274 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:52:46.95141 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:52:46.95626 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:52:46.95657 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:52:53.95708 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:52:54.01478 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6592405418 2016-12-01T18:52:54.01527 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6592405418 2016-12-01T18:52:54.07465 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:52:54.07470 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:52:54.12135 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:52:54.12137 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:52:54.12137 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:52:54.12138 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:52:54.12138 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:52:54.12139 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:52:54.12139 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:52:54.12140 0.03121747] 2016-12-01T18:52:54.12140 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:52:54.12141 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:52:54.12141 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:52:54.12142 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:52:54.12347 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:52:54.12438 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:52:54.12479 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:53:01.12543 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:53:01.17418 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6579126289 2016-12-01T18:53:01.17545 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6579126289 2016-12-01T18:53:01.23580 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:53:01.23601 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:53:01.34782 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:53:01.34789 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:53:01.34796 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:53:01.34802 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:53:01.34856 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:53:01.34859 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:53:01.34860 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:53:01.34860 0.03121747] 2016-12-01T18:53:01.34865 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:53:01.34871 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:53:01.34878 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:53:01.34884 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:53:01.34978 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:53:01.35030 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:53:01.35058 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:53:08.35082 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:53:08.40628 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6561997967 2016-12-01T18:53:08.40630 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6561997967 2016-12-01T18:53:08.46851 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:53:08.46853 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:53:08.66009 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:53:08.66016 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:53:08.66171 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:53:08.66172 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:53:08.66173 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:53:08.66173 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:53:08.66174 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:53:08.66174 0.03121747] 2016-12-01T18:53:08.66175 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:53:08.66175 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:53:08.66176 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:53:08.66176 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:53:08.66674 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:53:08.66783 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:53:08.66796 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:53:15.66847 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:53:15.68875 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6535713042 2016-12-01T18:53:15.68999 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6535713042 2016-12-01T18:53:15.75240 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:53:15.75242 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:53:15.78406 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:53:15.78409 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:53:15.78410 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:53:15.78410 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:53:15.78411 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:53:15.78411 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:53:15.78412 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:53:15.78412 0.03121747] 2016-12-01T18:53:15.78413 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:53:15.78413 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:53:15.78414 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:53:15.78414 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:53:15.78955 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:53:15.79333 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:53:15.79447 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:53:22.79444 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:53:22.84976 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6569157127 2016-12-01T18:53:22.85195 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6569157127 2016-12-01T18:53:22.91359 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:53:22.91371 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:53:22.94615 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:53:22.94617 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:53:22.94617 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:53:22.94617 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:53:22.94664 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:53:22.94665 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:53:22.94666 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:53:22.94666 0.03121747] 2016-12-01T18:53:22.94704 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:53:22.94705 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:53:22.94706 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:53:22.94706 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:53:22.94810 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:53:22.94881 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:53:22.94911 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:53:29.95075 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:53:30.00907 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6617009019 2016-12-01T18:53:30.01155 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6617009019 2016-12-01T18:53:30.07031 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:53:30.07046 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:53:30.10015 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:53:30.10017 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:53:30.10017 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:53:30.10018 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:53:30.10018 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:53:30.10019 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:53:30.10019 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:53:30.10020 0.03121747] 2016-12-01T18:53:30.10020 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:53:30.10021 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:53:30.10021 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:53:30.10022 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:53:30.10468 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:53:30.10534 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:53:30.10563 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:53:37.10613 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:53:37.16041 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6513644776 2016-12-01T18:53:37.16373 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6513644776 2016-12-01T18:53:37.22474 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:53:37.22495 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:53:37.25259 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:53:37.25267 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:53:37.25277 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:53:37.25284 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:53:37.25337 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:53:37.25338 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:53:37.25339 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:53:37.25339 0.03121747] 2016-12-01T18:53:37.25345 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:53:37.25351 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:53:37.25357 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:53:37.25364 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:53:37.26669 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:53:37.26996 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:53:37.27032 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:53:44.27264 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:53:44.32718 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6517518509 2016-12-01T18:53:44.32859 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6517518509 2016-12-01T18:53:44.39296 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:53:44.39305 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:53:44.41833 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:53:44.41839 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:53:44.41846 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:53:44.41853 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:53:44.41908 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:53:44.41909 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:53:44.41910 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:53:44.41910 0.03121747] 2016-12-01T18:53:44.41916 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:53:44.41927 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:53:44.41932 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:53:44.41937 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:53:44.42089 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:53:44.42913 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:53:44.42967 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:53:51.43148 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:53:51.49220 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6479301563 2016-12-01T18:53:51.49293 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6479301563 2016-12-01T18:53:51.55505 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:53:51.55507 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:53:51.59516 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:53:51.59518 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:53:51.59519 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:53:51.59522 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:53:51.59608 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:53:51.59610 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:53:51.59610 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:53:51.59611 0.03121747] 2016-12-01T18:53:51.59623 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:53:51.59633 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:53:51.59644 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:53:51.59655 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:53:51.59885 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:53:51.60007 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:53:51.60151 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:53:58.60444 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:53:58.66237 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6528094842 2016-12-01T18:53:58.66395 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6528094842 2016-12-01T18:53:58.72509 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:53:58.72530 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:53:58.75978 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:53:58.75990 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:53:58.76002 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:53:58.76014 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:53:58.76107 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:53:58.76108 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:53:58.76108 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:53:58.76109 0.03121747] 2016-12-01T18:53:58.76120 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:53:58.76130 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:53:58.76141 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:53:58.76151 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:53:58.76661 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:53:58.76847 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:53:58.76884 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:54:05.77010 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:54:05.82179 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.655795357 2016-12-01T18:54:05.82625 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.655795357 2016-12-01T18:54:05.88208 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:54:05.88210 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:54:05.91134 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:54:05.91136 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:54:05.91294 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:54:05.91295 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:54:05.91295 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:54:05.91296 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:54:05.91297 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:54:05.91297 0.03121747] 2016-12-01T18:54:05.91297 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:54:05.91298 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:54:05.91298 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:54:05.91299 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:54:05.91512 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:54:05.91578 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:54:05.91612 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:54:12.91640 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:54:12.92286 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.655556522 2016-12-01T18:54:12.92567 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.655556522 2016-12-01T18:54:12.98362 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:54:12.98375 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:54:13.02321 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:54:13.02333 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:54:13.02342 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:54:13.02351 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:54:13.02444 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:54:13.02445 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:54:13.02446 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:54:13.02446 0.03121747] 2016-12-01T18:54:13.02454 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:54:13.02462 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:54:13.02471 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:54:13.02476 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:54:13.03338 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:54:13.04003 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:54:13.04070 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:54:20.04099 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:54:20.10211 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6534539689 2016-12-01T18:54:20.10306 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6534539689 2016-12-01T18:54:20.16433 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:54:20.16466 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:54:20.20314 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:54:20.20328 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:54:20.20341 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:54:20.20349 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:54:20.20445 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:54:20.20446 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:54:20.20446 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:54:20.20447 0.03121747] 2016-12-01T18:54:20.20459 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:54:20.20469 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:54:20.20480 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:54:20.20491 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:54:20.20713 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:54:20.20769 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:54:20.20793 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:54:27.20815 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:54:27.26924 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6506288077 2016-12-01T18:54:27.27306 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6506288077 2016-12-01T18:54:27.33075 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:54:27.33086 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:54:27.36764 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:54:27.36766 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:54:27.36766 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:54:27.36767 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:54:27.36767 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:54:27.36768 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:54:27.36768 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:54:27.36769 0.03121747] 2016-12-01T18:54:27.36769 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:54:27.36770 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:54:27.36770 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:54:27.36770 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:54:27.36886 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:54:27.36944 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:54:27.36966 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:54:34.37024 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:54:34.37392 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6555795856 2016-12-01T18:54:34.37467 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6555795856 2016-12-01T18:54:34.43778 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:54:34.43792 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:54:34.47001 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:54:34.47007 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:54:34.47017 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:54:34.47028 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:54:34.47129 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:54:34.47130 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:54:34.47131 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:54:34.47132 0.03121747] 2016-12-01T18:54:34.47146 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:54:34.47151 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:54:34.47162 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:54:34.47172 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:54:34.47283 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:54:34.47856 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:54:34.47896 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:54:41.47952 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:54:41.48348 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6501363169 2016-12-01T18:54:41.48386 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6501363169 2016-12-01T18:54:41.54684 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:54:41.54687 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:54:41.57467 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:54:41.57469 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:54:41.57469 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:54:41.57469 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:54:41.57470 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:54:41.57470 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:54:41.57470 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:54:41.57471 0.03121747] 2016-12-01T18:54:41.57471 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:54:41.57471 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:54:41.57472 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:54:41.57472 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:54:41.57700 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:54:41.57771 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:54:41.57811 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:54:48.57817 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:54:48.58108 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6474118103 2016-12-01T18:54:48.58174 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6474118103 2016-12-01T18:54:48.64335 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:54:48.64350 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:54:48.79292 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:54:48.79294 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:54:48.79295 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:54:48.79296 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:54:48.79326 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:54:48.79329 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:54:48.79329 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:54:48.79330 0.03121747] 2016-12-01T18:54:48.79342 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:54:48.79352 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:54:48.79363 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:54:48.79373 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:54:48.79483 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:54:48.79698 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:54:48.79899 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:54:55.79952 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:54:55.80583 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6530079462 2016-12-01T18:54:55.80799 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6530079462 2016-12-01T18:54:55.86937 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:54:55.86939 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:54:55.90520 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:54:55.90522 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:54:55.90522 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:54:55.90523 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:54:55.90523 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:54:55.90524 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:54:55.90524 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:54:55.90525 0.03121747] 2016-12-01T18:54:55.90526 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:54:55.90692 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:54:55.90693 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:54:55.90694 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:54:55.91179 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:54:55.91566 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:54:55.91598 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:55:02.91641 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:55:02.92187 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6547285531 2016-12-01T18:55:02.92361 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6547285531 2016-12-01T18:55:02.98572 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:55:02.98574 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:55:03.02041 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:55:03.02044 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:55:03.02044 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:55:03.02046 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:55:03.02046 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:55:03.02047 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:55:03.02047 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:55:03.02048 0.03121747] 2016-12-01T18:55:03.02048 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:55:03.02048 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:55:03.02049 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:55:03.02049 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:55:03.02582 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:55:03.02648 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:55:03.02700 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:55:10.02763 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:55:10.05461 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6563761335 2016-12-01T18:55:10.05542 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6563761335 2016-12-01T18:55:10.11879 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:55:10.11881 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:55:10.16259 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:55:10.16262 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:55:10.16262 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:55:10.16262 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:55:10.16263 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:55:10.16263 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:55:10.16264 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:55:10.16264 0.03121747] 2016-12-01T18:55:10.16265 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:55:10.16265 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:55:10.16266 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:55:10.16266 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:55:10.16369 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:55:10.17045 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:55:10.17162 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:55:17.17234 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:55:17.17484 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6512467404 2016-12-01T18:55:17.17880 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6512467404 2016-12-01T18:55:17.23667 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:55:17.23670 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:55:17.27591 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:55:17.27594 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:55:17.27595 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:55:17.27595 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:55:17.27596 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:55:17.27596 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:55:17.27597 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:55:17.27597 0.03121747] 2016-12-01T18:55:17.27598 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:55:17.27599 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:55:17.27599 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:55:17.27600 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:55:17.28224 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:55:17.28310 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:55:17.28749 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:55:24.28478 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:55:24.33808 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6530450504 2016-12-01T18:55:24.33857 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6530450504 2016-12-01T18:55:24.40355 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:55:24.40358 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:55:24.42590 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:55:24.42598 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:55:24.42608 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:55:24.42616 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:55:24.42711 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:55:24.42712 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:55:24.42713 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:55:24.42714 0.03121747] 2016-12-01T18:55:24.42722 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:55:24.42729 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:55:24.42739 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:55:24.42747 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:55:24.43135 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:55:24.43450 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:55:24.43551 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:55:31.43691 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:55:31.43997 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6555496299 2016-12-01T18:55:31.44062 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6555496299 2016-12-01T18:55:31.50371 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:55:31.50373 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:55:31.53927 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:55:31.53930 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:55:31.53931 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:55:31.53931 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:55:31.54058 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:55:31.54060 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:55:31.54060 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:55:31.54061 0.03121747] 2016-12-01T18:55:31.54061 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:55:31.54062 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:55:31.54063 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:55:31.54063 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:55:31.54821 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:55:31.55302 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:55:31.55385 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:55:38.55420 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:55:38.60162 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.651509858 2016-12-01T18:55:38.60227 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.651509858 2016-12-01T18:55:38.66460 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:55:38.66463 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:55:38.68342 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:55:38.68355 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:55:38.68369 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:55:38.68380 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:55:38.68491 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:55:38.68493 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:55:38.68493 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:55:38.68494 0.03121747] 2016-12-01T18:55:38.68508 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:55:38.68520 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:55:38.68534 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:55:38.68547 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:55:38.68694 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:55:38.68869 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:55:38.68913 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:55:45.69056 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:55:45.70132 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6588813497 2016-12-01T18:55:45.70177 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6588813497 2016-12-01T18:55:45.76692 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T18:55:45.76709 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.0968523887, 59.2191038805, 59.3371987273, 59.4409935849, 59.5279703936, 59.6021183492, 59.6204313427, 59.6372443349, 59.6093122583, 59.5477637708, 59.4577134897, 59.3455004347, 59.1885448285, 59.0152857413, 58.7983764857, 58.6616996121, 59.112559458, 58.9951974434, 58.8834280787, 58.9926892117 2016-12-01T18:55:45.78892 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T18:55:45.78895 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 11 2016-12-01T18:55:45.78895 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 42.0 2016-12-01T18:55:45.78896 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0448444589268 2016-12-01T18:55:45.79039 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.034929 0.03374138 0.02965567 0.02485052 0.02118513 0.00523228 2016-12-01T18:55:45.79041 0.00480371 -0.00798059 -0.01758528 -0.02572865 -0.03206087 -0.04484446 2016-12-01T18:55:45.79042 -0.0495026 -0.06197407 -0.03905054 0.1288171 -0.033532 -0.0319341 2016-12-01T18:55:45.79042 0.03121747] 2016-12-01T18:55:45.79043 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -22.2992990423 2016-12-01T18:55:45.79043 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T18:55:45.79044 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 42.0 2016-12-01T18:55:45.79045 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3455004347 2016-12-01T18:55:45.80057 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3455004347 2016-12-01T18:55:45.80520 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T18:55:45.80692 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T18:55:47.33493 TCS_ITMX_CO2 REQUEST: LASER_UP 2016-12-01T18:55:47.33522 TCS_ITMX_CO2 calculating path: FIND_LOCK_POINT->LASER_UP 2016-12-01T18:55:47.33550 TCS_ITMX_CO2 new target: LOCK_LASER 2016-12-01T18:55:52.80752 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T18:55:52.86106 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.6522061683 2016-12-01T18:55:52.86157 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.6522061683 2016-12-01T18:55:52.98563 TCS_ITMX_CO2 EDGE: FIND_LOCK_POINT->LOCK_LASER 2016-12-01T18:55:52.98594 TCS_ITMX_CO2 calculating path: LOCK_LASER->LASER_UP 2016-12-01T18:55:52.98632 TCS_ITMX_CO2 new target: RESET_PZT_VOLTAGE 2016-12-01T18:55:52.98700 TCS_ITMX_CO2 executing state: LOCK_LASER (-16) 2016-12-01T18:55:52.98727 TCS_ITMX_CO2 [LOCK_LASER.enter] 2016-12-01T18:55:53.24250 TCS_ITMX_CO2 [LOCK_LASER.main] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT => ON: OFFSET, OUTPUT 2016-12-01T18:55:53.24732 TCS_ITMX_CO2 [LOCK_LASER.main] ezca: H1:TCS-ITMX_CO2_PZT_SERVO_GAIN_SW1 => 16 2016-12-01T18:55:53.37889 TCS_ITMX_CO2 [LOCK_LASER.main] ezca: H1:TCS-ITMX_CO2_PZT_SERVO_GAIN_SW2 => 1024 2016-12-01T18:55:53.50418 TCS_ITMX_CO2 [LOCK_LASER.main] ezca: H1:TCS-ITMX_CO2_PZT_SERVO_GAIN => ON: FM1, OUTPUT 2016-12-01T18:55:53.67859 TCS_ITMX_CO2 EDGE: LOCK_LASER->RESET_PZT_VOLTAGE 2016-12-01T18:55:53.67967 TCS_ITMX_CO2 calculating path: RESET_PZT_VOLTAGE->LASER_UP 2016-12-01T18:55:53.68012 TCS_ITMX_CO2 new target: ENGAGE_CHILLER_SERVO 2016-12-01T18:55:53.68083 TCS_ITMX_CO2 executing state: RESET_PZT_VOLTAGE (-17) 2016-12-01T18:55:53.68109 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.enter] 2016-12-01T18:55:53.74284 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 41.890625 2016-12-01T18:55:53.74332 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] timer['wait'] = 0.1 2016-12-01T18:55:53.80442 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 41.78125 2016-12-01T18:55:53.86792 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 41.671875 2016-12-01T18:55:53.93159 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 41.5625 2016-12-01T18:55:53.99194 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 41.453125 2016-12-01T18:55:54.05559 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 41.34375 2016-12-01T18:55:54.11734 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 41.234375 2016-12-01T18:55:54.18110 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 41.125 2016-12-01T18:55:54.25190 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 41.015625 2016-12-01T18:55:54.31104 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 40.90625 2016-12-01T18:55:54.37194 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 40.796875 2016-12-01T18:55:54.43309 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 40.6875 2016-12-01T18:55:54.50306 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 40.578125 2016-12-01T18:55:54.56217 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 40.46875 2016-12-01T18:55:54.62472 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 40.359375 2016-12-01T18:55:54.68527 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 40.25 2016-12-01T18:55:54.74841 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 40.140625 2016-12-01T18:55:54.81027 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 40.03125 2016-12-01T18:55:54.87598 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 39.921875 2016-12-01T18:55:54.93698 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 39.8125 2016-12-01T18:55:55.01392 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 39.703125 2016-12-01T18:55:55.06645 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 39.59375 2016-12-01T18:55:55.13048 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 39.484375 2016-12-01T18:55:55.19099 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 39.375 2016-12-01T18:55:55.25461 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 39.265625 2016-12-01T18:55:55.31830 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 39.15625 2016-12-01T18:55:55.38286 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 39.046875 2016-12-01T18:55:55.44183 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 38.9375 2016-12-01T18:55:55.51401 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 38.828125 2016-12-01T18:55:55.56905 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 38.71875 2016-12-01T18:55:55.63221 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 38.609375 2016-12-01T18:55:55.69226 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 38.5 2016-12-01T18:55:55.75627 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 38.390625 2016-12-01T18:55:55.81760 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 38.28125 2016-12-01T18:55:55.88147 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 38.171875 2016-12-01T18:55:55.94314 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 38.0625 2016-12-01T18:55:56.01169 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 37.953125 2016-12-01T18:55:56.06700 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 37.84375 2016-12-01T18:55:56.13162 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 37.734375 2016-12-01T18:55:56.19321 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 37.625 2016-12-01T18:55:56.25858 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 37.515625 2016-12-01T18:55:56.31879 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 37.40625 2016-12-01T18:55:56.38152 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 37.296875 2016-12-01T18:55:56.44702 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 37.1875 2016-12-01T18:55:56.50707 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 37.078125 2016-12-01T18:55:56.57111 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 36.96875 2016-12-01T18:55:56.63949 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 36.859375 2016-12-01T18:55:56.69771 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 36.75 2016-12-01T18:55:56.76397 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 36.640625 2016-12-01T18:55:56.82192 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 36.53125 2016-12-01T18:55:56.88370 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 36.421875 2016-12-01T18:55:56.94557 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 36.3125 2016-12-01T18:55:57.01040 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 36.203125 2016-12-01T18:55:57.07162 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 36.09375 2016-12-01T18:55:57.13553 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 35.984375 2016-12-01T18:55:57.19707 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 35.875 2016-12-01T18:55:57.26269 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 35.765625 2016-12-01T18:55:57.32283 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 35.65625 2016-12-01T18:55:57.38996 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 35.546875 2016-12-01T18:55:57.44958 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 35.4375 2016-12-01T18:55:57.51225 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 35.328125 2016-12-01T18:55:57.57463 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 35.21875 2016-12-01T18:55:57.63695 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 35.109375 2016-12-01T18:55:57.69989 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 35.0 2016-12-01T18:55:57.80040 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] timer['wait'] done 2016-12-01T18:55:57.88731 TCS_ITMX_CO2 EDGE: RESET_PZT_VOLTAGE->ENGAGE_CHILLER_SERVO 2016-12-01T18:55:57.88772 TCS_ITMX_CO2 calculating path: ENGAGE_CHILLER_SERVO->LASER_UP 2016-12-01T18:55:57.88815 TCS_ITMX_CO2 new target: ISS_ENGAGE 2016-12-01T18:55:57.88885 TCS_ITMX_CO2 executing state: ENGAGE_CHILLER_SERVO (-11) 2016-12-01T18:55:57.88917 TCS_ITMX_CO2 [ENGAGE_CHILLER_SERVO.enter] 2016-12-01T18:55:57.89949 TCS_ITMX_CO2 [ENGAGE_CHILLER_SERVO.main] ezca: H1:TCS-ITMX_CO2_CHILLER_SERVO_GAIN_SW1 => 20 2016-12-01T18:55:58.15167 TCS_ITMX_CO2 [ENGAGE_CHILLER_SERVO.main] ezca: H1:TCS-ITMX_CO2_CHILLER_SERVO_GAIN => ON: INPUT, FM1, FM2, OUTPUT 2016-12-01T18:55:58.40400 TCS_ITMX_CO2 [ENGAGE_CHILLER_SERVO.main] ezca: H1:TCS-ITMX_CO2_CHILLER_OUT_GAIN => ON: INPUT, OUTPUT 2016-12-01T18:55:58.57592 TCS_ITMX_CO2 EDGE: ENGAGE_CHILLER_SERVO->ISS_ENGAGE 2016-12-01T18:55:58.57621 TCS_ITMX_CO2 calculating path: ISS_ENGAGE->LASER_UP 2016-12-01T18:55:58.57647 TCS_ITMX_CO2 new target: LASER_UP 2016-12-01T18:55:58.57688 TCS_ITMX_CO2 executing state: ISS_ENGAGE (-13) 2016-12-01T18:55:58.57707 TCS_ITMX_CO2 [ISS_ENGAGE.enter] 2016-12-01T18:55:58.76796 TCS_ITMX_CO2 EDGE: ISS_ENGAGE->LASER_UP 2016-12-01T18:55:58.76836 TCS_ITMX_CO2 calculating path: LASER_UP->LASER_UP 2016-12-01T18:55:58.76905 TCS_ITMX_CO2 executing state: LASER_UP (-15) 2016-12-01T18:55:58.76930 TCS_ITMX_CO2 [LASER_UP.enter] 2016-12-01T22:32:36.41826 TCS_ITMX_CO2 [LASER_UP.run] laser unlocked. jumping to find new locking point 2016-12-01T22:32:36.48044 TCS_ITMX_CO2 JUMP target: FIND_LOCK_POINT 2016-12-01T22:32:36.48061 TCS_ITMX_CO2 [LASER_UP.exit] 2016-12-01T22:32:36.54243 TCS_ITMX_CO2 JUMP: LASER_UP->FIND_LOCK_POINT 2016-12-01T22:32:36.54283 TCS_ITMX_CO2 calculating path: FIND_LOCK_POINT->LASER_UP 2016-12-01T22:32:36.54327 TCS_ITMX_CO2 new target: LOCK_LASER 2016-12-01T22:32:36.54396 TCS_ITMX_CO2 executing state: FIND_LOCK_POINT (-12) 2016-12-01T22:32:36.54630 TCS_ITMX_CO2 [FIND_LOCK_POINT.enter] 2016-12-01T22:32:36.68147 TCS_ITMX_CO2 [FIND_LOCK_POINT.main] ezca: H1:TCS-ITMX_CO2_PZT_SERVO_GAIN_SW2 => 1024 2016-12-01T22:32:36.80698 TCS_ITMX_CO2 [FIND_LOCK_POINT.main] ezca: H1:TCS-ITMX_CO2_PZT_SERVO_GAIN => OFF: OUTPUT 2016-12-01T22:32:36.81937 TCS_ITMX_CO2 [FIND_LOCK_POINT.main] ezca: H1:TCS-ITMX_CO2_PZT_SERVO_GAIN_SW1 => 16 2016-12-01T22:32:37.07170 TCS_ITMX_CO2 [FIND_LOCK_POINT.main] ezca: H1:TCS-ITMX_CO2_PZT_SERVO_GAIN => OFF: FM1 2016-12-01T22:32:37.07406 TCS_ITMX_CO2 [FIND_LOCK_POINT.main] ezca: H1:TCS-ITMX_CO2_CHILLER_SERVO_GAIN_SW1 => 20 2016-12-01T22:32:37.32890 TCS_ITMX_CO2 [FIND_LOCK_POINT.main] ezca: H1:TCS-ITMX_CO2_CHILLER_SERVO_GAIN => OFF: INPUT, FM1 2016-12-01T22:32:37.58094 TCS_ITMX_CO2 [FIND_LOCK_POINT.main] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT => ON: OFFSET, OUTPUT 2016-12-01T22:32:37.61472 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 3.5 2016-12-01T22:32:37.61500 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T22:32:40.61522 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T22:32:40.69359 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 7.0 2016-12-01T22:32:40.69533 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T22:32:43.69578 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T22:32:43.78389 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 10.5 2016-12-01T22:32:43.78423 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T22:32:46.78469 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T22:32:46.87872 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 14.0 2016-12-01T22:32:46.87936 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T22:32:49.87986 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T22:32:49.94574 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 17.5 2016-12-01T22:32:49.94600 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T22:32:52.94623 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T22:32:53.02897 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 21.0 2016-12-01T22:32:53.03266 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T22:32:56.03309 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T22:32:56.11561 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 24.5 2016-12-01T22:32:56.11702 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T22:32:59.11738 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T22:32:59.19984 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 28.0 2016-12-01T22:32:59.20014 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T22:33:02.20010 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T22:33:02.27910 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 31.5 2016-12-01T22:33:02.27939 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T22:33:05.28290 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T22:33:05.35631 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 35.0 2016-12-01T22:33:05.35677 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T22:33:08.35688 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T22:33:08.43942 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 38.5 2016-12-01T22:33:08.43956 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T22:33:11.43990 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T22:33:11.52250 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 42.0 2016-12-01T22:33:11.53261 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T22:33:14.53475 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T22:33:14.60582 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 45.5 2016-12-01T22:33:14.60653 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T22:33:17.60650 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T22:33:17.69221 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 49.0 2016-12-01T22:33:17.69350 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T22:33:20.69301 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T22:33:20.78795 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 52.5 2016-12-01T22:33:20.78836 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T22:33:23.78832 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T22:33:23.86432 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 56.0 2016-12-01T22:33:23.86563 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T22:33:26.87121 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T22:33:26.94598 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 59.5 2016-12-01T22:33:26.94626 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T22:33:29.94624 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T22:33:30.03745 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 63.0 2016-12-01T22:33:30.03893 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T22:33:33.03796 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T22:33:33.11542 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 66.5 2016-12-01T22:33:33.11715 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T22:33:36.11717 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T22:33:36.19749 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 70.0 2016-12-01T22:33:36.20029 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] = 3 2016-12-01T22:33:39.19774 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['wait'] done 2016-12-01T22:33:39.28450 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 3.5, 7.0, 10.5, 14.0, 17.5, 21.0, 24.5, 28.0, 31.5, 35.0, 38.5, 42.0, 45.5, 49.0, 52.5, 56.0, 59.5, 63.0, 66.5, 70.0 2016-12-01T22:33:39.28452 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.075907374, 59.1566572572, 59.2357291824, 59.3138316781, 59.4004394948, 59.4702452905, 59.5439997968, 59.5983651647, 59.6308274857, 59.6464512022, 59.6354207709, 59.6023444719, 59.5447961562, 59.459160565, 59.3484500647, 59.202787457, 59.0450665473, 58.865380559, 58.6610844209, 58.9092843236 2016-12-01T22:33:39.71861 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slopecheck, negative slope 2 2016-12-01T22:33:39.71864 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midslope matrix index 14 2016-12-01T22:33:39.71864 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] midvoltage 52.5 2016-12-01T22:33:39.71865 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope -0.0416178879142 2016-12-01T22:33:39.71930 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] slope [ 0.0230714 0.02259198 0.022315 0.02474509 0.01994451 0.02107272 2016-12-01T22:33:39.71932 0.01553296 0.00927495 0.00446392 -0.00315155 -0.00945037 -0.01644238 2016-12-01T22:33:39.71935 -0.02446731 -0.03163157 -0.04161789 -0.04506312 -0.05133885 -0.05837033 2016-12-01T22:33:39.71935 0.07091426] 2016-12-01T22:33:39.71949 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] gain setting for servo is -24.0281294923 2016-12-01T22:33:39.71958 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 2 2016-12-01T22:33:39.71969 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 52.5 2016-12-01T22:33:39.71981 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] 59.3484500647 2016-12-01T22:33:39.72083 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 52.5 2016-12-01T22:33:39.72273 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LASERPOWER_SETPOINT => 59.3484500647 2016-12-01T22:33:39.72381 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.3484500647 2016-12-01T22:33:39.72723 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_PZT_SERVO_GAIN_GAIN => 24.0281294923 2016-12-01T22:33:39.72942 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] laser setpoint chosen 2016-12-01T22:33:39.73023 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] = 7 2016-12-01T22:33:46.73102 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] timer['stabilize'] done 2016-12-01T22:33:46.77766 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] the actual power at the new pzt setpoint is 59.131694061 2016-12-01T22:33:46.78541 TCS_ITMX_CO2 [FIND_LOCK_POINT.run] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT_OFFSET => 59.131694061 2016-12-01T22:33:46.89967 TCS_ITMX_CO2 EDGE: FIND_LOCK_POINT->LOCK_LASER 2016-12-01T22:33:46.89968 TCS_ITMX_CO2 calculating path: LOCK_LASER->LASER_UP 2016-12-01T22:33:46.89969 TCS_ITMX_CO2 new target: RESET_PZT_VOLTAGE 2016-12-01T22:33:46.89969 TCS_ITMX_CO2 executing state: LOCK_LASER (-16) 2016-12-01T22:33:46.89975 TCS_ITMX_CO2 [LOCK_LASER.enter] 2016-12-01T22:33:47.15509 TCS_ITMX_CO2 [LOCK_LASER.main] ezca: H1:TCS-ITMX_CO2_LSRPWR_SET_POINT => ON: OFFSET, OUTPUT 2016-12-01T22:33:47.16182 TCS_ITMX_CO2 [LOCK_LASER.main] ezca: H1:TCS-ITMX_CO2_PZT_SERVO_GAIN_SW1 => 16 2016-12-01T22:33:47.28792 TCS_ITMX_CO2 [LOCK_LASER.main] ezca: H1:TCS-ITMX_CO2_PZT_SERVO_GAIN_SW2 => 1024 2016-12-01T22:33:47.41332 TCS_ITMX_CO2 [LOCK_LASER.main] ezca: H1:TCS-ITMX_CO2_PZT_SERVO_GAIN => ON: FM1, OUTPUT 2016-12-01T22:33:47.58950 TCS_ITMX_CO2 EDGE: LOCK_LASER->RESET_PZT_VOLTAGE 2016-12-01T22:33:47.58990 TCS_ITMX_CO2 calculating path: RESET_PZT_VOLTAGE->LASER_UP 2016-12-01T22:33:47.59032 TCS_ITMX_CO2 new target: ENGAGE_CHILLER_SERVO 2016-12-01T22:33:47.59101 TCS_ITMX_CO2 executing state: RESET_PZT_VOLTAGE (-17) 2016-12-01T22:33:47.59119 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.enter] 2016-12-01T22:33:47.65555 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 52.2265625 2016-12-01T22:33:47.65603 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] timer['wait'] = 0.1 2016-12-01T22:33:47.72032 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 51.953125 2016-12-01T22:33:47.78354 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 51.6796875 2016-12-01T22:33:47.84545 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 51.40625 2016-12-01T22:33:47.90566 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 51.1328125 2016-12-01T22:33:47.96861 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 50.859375 2016-12-01T22:33:48.03421 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 50.5859375 2016-12-01T22:33:48.09510 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 50.3125 2016-12-01T22:33:48.15599 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 50.0390625 2016-12-01T22:33:48.21813 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 49.765625 2016-12-01T22:33:48.28353 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 49.4921875 2016-12-01T22:33:48.34400 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 49.21875 2016-12-01T22:33:48.40819 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 48.9453125 2016-12-01T22:33:48.47144 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 48.671875 2016-12-01T22:33:48.53724 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 48.3984375 2016-12-01T22:33:48.59767 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 48.125 2016-12-01T22:33:48.66885 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 47.8515625 2016-12-01T22:33:48.72280 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 47.578125 2016-12-01T22:33:48.79028 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 47.3046875 2016-12-01T22:33:48.84787 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 47.03125 2016-12-01T22:33:48.91482 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 46.7578125 2016-12-01T22:33:48.97850 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 46.484375 2016-12-01T22:33:49.04761 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 46.2109375 2016-12-01T22:33:49.10658 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 45.9375 2016-12-01T22:33:49.17517 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 45.6640625 2016-12-01T22:33:49.23024 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 45.390625 2016-12-01T22:33:49.29634 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 45.1171875 2016-12-01T22:33:49.35568 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 44.84375 2016-12-01T22:33:49.42050 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 44.5703125 2016-12-01T22:33:49.47794 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 44.296875 2016-12-01T22:33:49.54315 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 44.0234375 2016-12-01T22:33:49.60415 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 43.75 2016-12-01T22:33:49.66632 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 43.4765625 2016-12-01T22:33:49.72955 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 43.203125 2016-12-01T22:33:49.79152 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 42.9296875 2016-12-01T22:33:49.85605 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 42.65625 2016-12-01T22:33:49.91865 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 42.3828125 2016-12-01T22:33:49.98516 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 42.109375 2016-12-01T22:33:50.04789 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 41.8359375 2016-12-01T22:33:50.10908 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 41.5625 2016-12-01T22:33:50.17534 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 41.2890625 2016-12-01T22:33:50.23527 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 41.015625 2016-12-01T22:33:50.29933 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 40.7421875 2016-12-01T22:33:50.36125 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 40.46875 2016-12-01T22:33:50.42400 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 40.1953125 2016-12-01T22:33:50.48845 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 39.921875 2016-12-01T22:33:50.54934 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 39.6484375 2016-12-01T22:33:50.61393 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 39.375 2016-12-01T22:33:50.67233 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 39.1015625 2016-12-01T22:33:50.74080 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 38.828125 2016-12-01T22:33:50.80589 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 38.5546875 2016-12-01T22:33:50.86177 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 38.28125 2016-12-01T22:33:50.93150 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 38.0078125 2016-12-01T22:33:50.99146 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 37.734375 2016-12-01T22:33:51.04986 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 37.4609375 2016-12-01T22:33:51.11318 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 37.1875 2016-12-01T22:33:51.17566 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 36.9140625 2016-12-01T22:33:51.24055 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 36.640625 2016-12-01T22:33:51.30677 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 36.3671875 2016-12-01T22:33:51.36619 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 36.09375 2016-12-01T22:33:51.42949 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 35.8203125 2016-12-01T22:33:51.49562 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 35.546875 2016-12-01T22:33:51.55646 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 35.2734375 2016-12-01T22:33:51.61910 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] ezca: H1:TCS-ITMX_CO2_PZT_SET_POINT_OFFSET => 35.0 2016-12-01T22:33:51.72155 TCS_ITMX_CO2 [RESET_PZT_VOLTAGE.run] timer['wait'] done 2016-12-01T22:33:51.80536 TCS_ITMX_CO2 EDGE: RESET_PZT_VOLTAGE->ENGAGE_CHILLER_SERVO 2016-12-01T22:33:51.80538 TCS_ITMX_CO2 calculating path: ENGAGE_CHILLER_SERVO->LASER_UP 2016-12-01T22:33:51.80539 TCS_ITMX_CO2 new target: ISS_ENGAGE 2016-12-01T22:33:51.80539 TCS_ITMX_CO2 executing state: ENGAGE_CHILLER_SERVO (-11) 2016-12-01T22:33:51.80540 TCS_ITMX_CO2 [ENGAGE_CHILLER_SERVO.enter] 2016-12-01T22:33:51.81472 TCS_ITMX_CO2 [ENGAGE_CHILLER_SERVO.main] ezca: H1:TCS-ITMX_CO2_CHILLER_SERVO_GAIN_SW1 => 20 2016-12-01T22:33:52.06830 TCS_ITMX_CO2 [ENGAGE_CHILLER_SERVO.main] ezca: H1:TCS-ITMX_CO2_CHILLER_SERVO_GAIN => ON: INPUT, FM1, FM2, OUTPUT 2016-12-01T22:33:52.32374 TCS_ITMX_CO2 [ENGAGE_CHILLER_SERVO.main] ezca: H1:TCS-ITMX_CO2_CHILLER_OUT_GAIN => ON: INPUT, OUTPUT 2016-12-01T22:33:52.49480 TCS_ITMX_CO2 EDGE: ENGAGE_CHILLER_SERVO->ISS_ENGAGE 2016-12-01T22:33:52.49520 TCS_ITMX_CO2 calculating path: ISS_ENGAGE->LASER_UP 2016-12-01T22:33:52.49559 TCS_ITMX_CO2 new target: LASER_UP 2016-12-01T22:33:52.49629 TCS_ITMX_CO2 executing state: ISS_ENGAGE (-13) 2016-12-01T22:33:52.49648 TCS_ITMX_CO2 [ISS_ENGAGE.enter] 2016-12-01T22:33:52.68308 TCS_ITMX_CO2 EDGE: ISS_ENGAGE->LASER_UP 2016-12-01T22:33:52.68347 TCS_ITMX_CO2 calculating path: LASER_UP->LASER_UP 2016-12-01T22:33:52.68421 TCS_ITMX_CO2 executing state: LASER_UP (-15) 2016-12-01T22:33:52.68440 TCS_ITMX_CO2 [LASER_UP.enter]