#script for [pasting into guardian shell for switching DARM control from ETMY to ETMX Feb 29th 2017

#set up stuff
ezca.get_LIGOFilter('SUS-ETMX_L3_LOCK_L').only_on('INPUT', 'FM5', 'FM9', 'FM10','OUTPUT', 'DECIMATION') #on ETMY we also notch vStop8+9
ezca.get_LIGOFilter('SUS-ETMX_L3_DRIVEALIGN_L2L').only_on('INPUT', 'FM4', 'FM5','OUTPUT', 'DECIMATION') 
ezca['SUS-ETMX_L3_DRIVEALIGN_L2L_GAIN']=-30
ezca.get_LIGOFilter('SUS-ETMX_L2_LOCK_L').only_on('INPUT', 'FM7','OUTPUT', 'DECIMATION') 
ezca['SUS-ETMX_L2_LOCK_L_GAIN']=15

ezca['SUS-ETMX_L2_LOCK_OUTSW_L']=1
ezca.get_LIGOFilter('SUS-ETMX_L2_DRIVEALIGN_L2L').only_on('INPUT', 'FM6', 'FM7','OUTPUT', 'DECIMATION') 
ezca.get_LIGOFilter('SUS-ETMX_L1_LOCK_L').only_on('INPUT', 'FM1', 'FM3','FM4', 'FM6', 'FM7', 'FM9', 'FM10','OUTPUT', 'DECIMATION')
ezca['SUS-ETMX_L1_LOCK_L_GAIN']=0.6

ezca['SUS-ETMX_L3_LOCK_L_TRAMP']=10
ezca['SUS-ETMY_L3_LOCK_L_TRAMP']=10

#make the swap half way
ezca['SUS-ETMX_L3_LOCK_L_GAIN']=1.25/2
ezca['SUS-ETMY_L3_LOCK_L_GAIN']=.75 #according to measurement half switched on July 28th, we should use a gain of 1.5 to completely transition to X
#ACTUALLY MAKE THE SWAP
ezca['SUS-ETMX_L3_LOCK_L_GAIN']=1.25
ezca['SUS-ETMY_L3_LOCK_L_GAIN']=0

#reset to normal configuration

ezca.get_LIGOFilter('SUS-ETMX_L3_LOCK_L').only_on('INPUT','OUTPUT', 'DECIMATION')
ezca.get_LIGOFilter('SUS-ETMX_L3_DRIVEALIGN_L2L').only_on('INPUT','OUTPUT', 'DECIMATION')
ezca.get_LIGOFilter('SUS-ETMX_L2_LOCK_L').only_on('INPUT','OUTPUT', 'DECIMATION')  
ezca.get_LIGOFilter('SUS-ETMX_L2_DRIVEALIGN_L2L').only_on('INPUT','OUTPUT', 'DECIMATION')
ezca.get_LIGOFilter('SUS-ETMX_L1_LOCK_L').only_on('INPUT', 'FM1', 'FM2','FM5', 'FM8','OUTPUT', 'DECIMATION') 
ezca['SUS-ETMX_L2_LOCK_OUTSW_L']=0