patrick.thomas@zotws3:~$ check_h1_files_svn_status -c SVN status of front end code source files... M /opt/rtcds/userapps/release/lsc/h1/models/h1lsc.mdl sheila.dwyer Aug 27 13:30 M /opt/rtcds/userapps/release/omc/h1/models/h1omc.mdl sheila.dwyer Aug 27 16:02 M /opt/rtcds/userapps/release/sus/h1/models/h1susitmx.mdl sheila.dwyer Aug 27 16:04 M /opt/rtcds/userapps/release/sus/h1/models/h1susitmy.mdl sheila.dwyer Aug 28 11:41 done (list of files scanned can be found in /tmp/tmp.iVXiaulsrj) patrick.thomas@zotws3:~$ check_h1_files_svn_status -f SVN status of filter module files... M /opt/rtcds/userapps/release/sus/h1/filterfiles/H1SUSITMY.txt jeffrey.kissel Aug 28 11:47 M /opt/rtcds/userapps/release/sus/h1/filterfiles/H1SUSITMX.txt kiwamu.izumi Aug 27 16:11 M /opt/rtcds/userapps/release/lsc/h1/filterfiles/H1LSC.txt kiwamu.izumi Aug 27 13:40 M /opt/rtcds/userapps/release/omc/h1/filterfiles/H1OMC.txt sheila.dwyer Aug 27 16:11 done (list of filter module files scanned can be found in /tmp/tmp.BqK4OO73rD patrick.thomas@zotws3:~$ check_h1_files_svn_status -g SVN status of guardian files... /opt/rtcds/userapps/release/cal/common/guardian/INJ_TRANS.py:124: UserWarning: Could not read schedule file. No hardware injections will be scheduled. warnings.warn("Could not read schedule file. No hardware injections will be scheduled.") -rw-rw-r-- 1 thomas.shaffer controls 55289 Sep 3 10:40 /opt/rtcds/userapps/release/isc/h1/guardian/ALIGN_IFO.py -rw-rw-r-- 1 sheila.dwyer controls 186412 Sep 3 10:56 /opt/rtcds/userapps/release/isc/h1/guardian/ISC_LOCK.py -rw-rw-r-- 1 thomas.shaffer controls 10837 Sep 3 10:39 /opt/rtcds/userapps/release/isc/h1/guardian/lscparams.py -rw-rw-r-- 1 thomas.shaffer controls 22248 Aug 29 15:09 /opt/rtcds/userapps/release/isi/h1/guardian/SEI_CONFIG/manager.py done (list of guardian files scanned can be found in /tmp/tmp.dhP0bGAn5H) patrick.thomas@zotws3:~$ check_sdf_snapfiles_status WARNING: local modification on file /opt/rtcds/userapps/trunk/hpi/h1/burtfiles/h1hpiham1_safe.snap WARNING: local modification on file /opt/rtcds/userapps/trunk/hpi/h1/burtfiles/h1hpietmy_safe.snap WARNING: local modification on file /opt/rtcds/userapps/trunk/isi/h1/burtfiles/h1isiham6_safe.snap WARNING: local modification on file /opt/rtcds/userapps/trunk/isi/h1/burtfiles/h1isietmy_safe.snap WARNING: local modification on file /opt/rtcds/userapps/trunk/sus/h1/burtfiles/h1susim_observe.snap WARNING: local modification on file /opt/rtcds/userapps/trunk/sus/h1/burtfiles/h1susitmy_down.snap WARNING: local modification on file /opt/rtcds/userapps/trunk/sus/h1/burtfiles/h1susitmx_down.snap WARNING: local modification on file /opt/rtcds/userapps/trunk/sus/h1/burtfiles/h1susetmx_down.snap WARNING: local modification on file /opt/rtcds/userapps/trunk/sus/h1/burtfiles/h1sustmsx_observe.snap WARNING: local modification on file /opt/rtcds/userapps/trunk/sus/h1/burtfiles/h1susetmy_down.snap WARNING: local modification on file /opt/rtcds/userapps/trunk/lsc/h1/burtfiles/h1lsc_down.snap WARNING: local modification on file /opt/rtcds/userapps/trunk/omc/h1/burtfiles/h1omc_down.snap WARNING: local modification on file /opt/rtcds/userapps/trunk/als/h1/burtfiles/h1alsex_down.snap WARNING: local modification on file /opt/rtcds/userapps/trunk/als/h1/burtfiles/h1alsey_down.snap WARNING: local modification on file /opt/rtcds/userapps/trunk/isi/h1/burtfiles/h1isietmy_OBSERVE.snap WARNING: local modification on file /opt/rtcds/userapps/trunk/sus/h1/burtfiles/h1susim_observe.snap WARNING: local modification on file /opt/rtcds/userapps/trunk/sus/h1/burtfiles/h1susitmy_observe.snap WARNING: local modification on file /opt/rtcds/userapps/trunk/sus/h1/burtfiles/h1susitmx_observe.snap WARNING: local modification on file /opt/rtcds/userapps/trunk/sus/h1/burtfiles/h1susetmx_observe.snap WARNING: local modification on file /opt/rtcds/userapps/trunk/sus/h1/burtfiles/h1sustmsx_observe.snap WARNING: local modification on file /opt/rtcds/userapps/trunk/sus/h1/burtfiles/h1susetmy_observe.snap done. 212 files checked, 0 errors 21 warnings