Notes
Operator,
Company,
Device S/N,
Device Type,
Date/Time,4/11/2018 9:03:18 AM
Comments



Acquisition Parameters
Rotation Frequency [Hz],10.000
Gain Aperture 1 [dB],56
Gain Aperture 2 [dB],53
Gain Power [dB],0
Filter Aperture 1 [kHz],3.5
Filter Aperture 2 [kHz],4.3
Sampling Resolution Aperture 1 [m],0.09152
Sampling Resolution Aperture 2 [m],0.09152


Analysis Parameter
Profile Averages,1
Rolling Profile Averages,1


Regions of Interest
Mode of Operation,Automatic
Aperture,ROI#,Left [m],Right [m],Enabled
1,1,1189.129,6639.921,Yes
2,1,2267.701,7083.064,Yes


Statistics
Samples,0
Parameter,ROI #,Value,Mean,S. Dev.,


Profiles Data

Position A1 ROI#1, Intensity A1 ROI#1,Position A2 ROI#1, Intensity A2 ROI#1
1189.12891,4.598,2267.70068,-1.160,
1189.22046,3.598,2267.79224,-1.160,
1189.31189,4.598,2267.88379,-1.160,
1189.40344,3.598,2267.97534,-1.160,
1189.49500,4.598,2268.06689,-1.160,
1189.58655,4.598,2268.15845,-1.160,
1189.67798,3.598,2268.24976,-1.160,
1189.76953,3.598,2268.34131,-1.160,
1189.86108,4.598,2268.43286,-1.160,
1189.95264,4.598,2268.52441,-1.160,
1190.04407,3.598,2268.61597,-1.160,
1190.13562,4.598,2268.70752,-1.160,
1190.22717,4.598,2268.79907,-1.160,
1190.31873,3.598,2268.89063,-1.160,
1190.41016,4.598,2268.98193,-1.160,
1190.50171,4.598,2269.07349,-1.160,
1190.59326,3.598,2269.16504,-0.160,
1190.68469,4.598,2269.25659,-1.160,
1190.77625,4.598,2269.34814,-1.160,
1190.86780,3.598,2269.43970,-1.160,
1190.95935,4.598,2269.53125,-2.160,
1191.05078,3.598,2269.62280,-2.160,
1191.14233,3.598,2269.71411,-2.160,
1191.23389,3.598,2269.80566,-2.160,
1191.32544,4.598,2269.89722,-2.160,
1191.41687,4.598,2269.98877,-2.160,
1191.50842,3.598,2270.08032,-2.160,
1191.59998,4.598,2270.17188,-2.160,
1191.69153,4.598,2270.26343,-2.160,
1191.78296,3.598,2270.35474,-2.160,
1191.87451,4.598,2270.44629,-2.160,
1191.96606,4.598,2270.53784,-2.160,
1192.05762,4.598,2270.62939,-1.160,
1192.14905,3.598,2270.72095,-2.160,
1192.24060,4.598,2270.81250,-1.160,
1192.33215,3.598,2270.90405,-1.160,
1192.42358,3.598,2270.99561,-2.160,
1192.51514,4.598,2271.08691,-2.160,
1192.60669,4.598,2271.17847,-1.160,
1192.69824,3.598,2271.27002,-1.160,
1192.78967,3.598,2271.36157,-2.160,
1192.88123,4.598,2271.45313,-2.160,
1192.97278,4.598,2271.54468,-1.160,
1193.06433,3.598,2271.63623,-2.160,
1193.15576,4.598,2271.72778,-2.160,
1193.24731,4.598,2271.81909,-1.160,
1193.33887,4.598,2271.91064,-2.160,
1193.43042,3.598,2272.00220,-2.160,
1193.52185,4.598,2272.09375,-1.160,
1193.61340,4.598,2272.18530,-1.160,
1193.70496,3.598,2272.27686,-2.160,
1193.79651,3.598,2272.36841,-2.160,
1193.88794,4.598,2272.45972,-1.160,
1193.97949,3.598,2272.55127,-2.160,
1194.07104,3.598,2272.64282,-2.160,
1194.16260,4.598,2272.73438,-1.160,
1194.25403,3.598,2272.82593,-1.160,
1194.34558,3.598,2272.91748,-2.160,
1194.43713,4.598,2273.00903,-1.160,
1194.52856,3.598,2273.10059,-2.160,
1194.62012,3.598,2273.19189,-2.160,
1194.71167,3.598,2273.28345,-1.160,
1194.80322,4.598,2273.37500,-1.160,
1194.89465,4.598,2273.46655,-1.160,
1194.98621,4.598,2273.55811,-1.160,
1195.07776,4.598,2273.64966,-1.160,
1195.16931,3.598,2273.74121,-1.160,
1195.26074,4.598,2273.83252,-2.160,
1195.35229,3.598,2273.92407,-1.160,
1195.44385,3.598,2274.01563,-1.160,
1195.53540,3.598,2274.10718,-2.160,
1195.62683,3.598,2274.19873,-1.160,
1195.71838,4.598,2274.29028,-1.160,
1195.80994,3.598,2274.38184,-2.160,
1195.90149,4.598,2274.47339,-2.160,
1195.99292,4.598,2274.56470,-2.160,
1196.08447,3.598,2274.65625,-2.160,
1196.17603,3.598,2274.74780,-2.160,
1196.26746,4.598,2274.83936,-1.160,
1196.35901,4.598,2274.93091,-2.160,
1196.45056,3.598,2275.02246,-1.160,
1196.54211,4.598,2275.11401,-1.160,
1196.63354,3.598,2275.20557,-1.160,
1196.72510,3.598,2275.29688,-1.160,
1196.81665,3.598,2275.38843,-1.160,
1196.90820,4.598,2275.47998,-1.160,
1196.99963,3.598,2275.57153,-1.160,
1197.09119,3.598,2275.66309,-1.160,
1197.18274,4.598,2275.75464,-1.160,
1197.27429,4.598,2275.84619,-1.160,
1197.36572,3.598,2275.93750,-1.160,
1197.45728,3.598,2276.02905,-1.160,
1197.54883,4.598,2276.12061,-1.160,
1197.64038,4.598,2276.21216,-2.160,
1197.73181,3.598,2276.30371,-1.160,
1197.82336,4.598,2276.39526,-2.160,
1197.91492,4.598,2276.48682,-1.160,
1198.00647,3.598,2276.57837,-2.160,
1198.09790,4.598,2276.66968,-2.160,
1198.18945,3.598,2276.76123,-1.160,
1198.28101,3.598,2276.85278,-1.160,
1198.37244,3.598,2276.94434,-1.160,
1198.46399,3.598,2277.03589,-1.160,
1198.55554,3.598,2277.12744,-1.160,
1198.64709,3.598,2277.21899,-2.160,
1198.73853,3.598,2277.31055,-1.160,
1198.83008,3.598,2277.40186,-1.160,
1198.92163,3.598,2277.49341,-2.160,
1199.01318,3.598,2277.58496,-2.160,
1199.10461,3.598,2277.67651,-1.160,
1199.19617,3.598,2277.76807,-2.160,
1199.28772,3.598,2277.85962,-2.160,
1199.37927,4.598,2277.95117,-1.160,
1199.47070,3.598,2278.04248,-1.160,
1199.56226,3.598,2278.13403,-2.160,
1199.65381,4.598,2278.22559,-1.160,
1199.74536,4.598,2278.31714,-1.160,
1199.83679,3.598,2278.40869,-2.160,
1199.92834,4.598,2278.50024,-1.160,
1200.01990,4.598,2278.59180,-1.160,
1200.11133,4.598,2278.68335,-1.160,
1200.20288,4.598,2278.77466,-1.160,
1200.29443,4.598,2278.86621,-1.160,
1200.38599,4.598,2278.95776,-2.160,
1200.47742,4.598,2279.04932,-1.160,
1200.56897,4.598,2279.14087,-1.160,
1200.66052,4.598,2279.23242,-1.160,
1200.75208,3.598,2279.32397,-2.160,
1200.84351,4.598,2279.41528,-1.160,
1200.93506,4.598,2279.50684,-1.160,
1201.02661,3.598,2279.59839,-1.160,
1201.11816,3.598,2279.68994,-2.160,
1201.20959,3.598,2279.78149,-1.160,
1201.30115,3.598,2279.87305,-2.160,
1201.39270,3.598,2279.96460,-2.160,
1201.48425,3.598,2280.05615,-1.160,
1201.57568,4.598,2280.14746,-1.160,
1201.66724,4.598,2280.23901,-2.160,
1201.75879,3.598,2280.33057,-2.160,
1201.85022,4.598,2280.42212,-2.160,
1201.94177,3.598,2280.51367,-2.160,
1202.03333,4.598,2280.60522,-1.160,
1202.12488,4.598,2280.69678,-2.160,
1202.21631,4.598,2280.78833,-2.160,
1202.30786,4.598,2280.87964,-1.160,
1202.39941,4.598,2280.97119,-1.160,
1202.49097,4.598,2281.06274,-1.160,
1202.58240,4.598,2281.15430,-2.160,
1202.67395,4.598,2281.24585,-1.160,
1202.76550,4.598,2281.33740,-1.160,
1202.85706,3.598,2281.42896,-1.160,
1202.94849,4.598,2281.52026,-1.160,
1203.04004,4.598,2281.61182,-1.160,
1203.13159,4.598,2281.70337,-2.160,
1203.22314,4.598,2281.79492,-2.160,
1203.31458,4.598,2281.88647,-1.160,
1203.40613,4.598,2281.97803,-2.160,
1203.49768,4.598,2282.06958,-1.160,
1203.58923,4.598,2282.16113,-2.160,
1203.68066,4.598,2282.25244,-1.160,
1203.77222,4.598,2282.34399,-1.160,
1203.86377,4.598,2282.43555,-1.160,
1203.95520,4.598,2282.52710,-1.160,
1204.04675,4.598,2282.61865,-1.160,
1204.13831,4.598,2282.71021,-1.160,
1204.22986,4.598,2282.80176,-2.160,
1204.32129,4.598,2282.89331,-1.160,
1204.41284,4.598,2282.98462,-2.160,
1204.50439,4.598,2283.07617,-2.160,
1204.59595,5.598,2283.16772,-1.160,
1204.68738,4.598,2283.25928,-2.160,
1204.77893,4.598,2283.35083,-2.160,
1204.87048,4.598,2283.44238,-1.160,
1204.96204,4.598,2283.53394,-2.160,
1205.05347,4.598,2283.62524,-2.160,
1205.14502,4.598,2283.71680,-1.160,
1205.23657,4.598,2283.80835,-1.160,
1205.32813,4.598,2283.89990,-2.160,
1205.41956,4.598,2283.99146,-2.160,
1205.51111,4.598,2284.08301,-2.160,
1205.60266,4.598,2284.17456,-1.160,
1205.69409,4.598,2284.26611,-2.160,
1205.78564,4.598,2284.35742,-1.160,
1205.87720,4.598,2284.44897,-1.160,
1205.96875,3.598,2284.54053,-2.160,
1206.06018,4.598,2284.63208,-2.160,
1206.15173,4.598,2284.72363,-2.160,
1206.24329,4.598,2284.81519,-3.160,
1206.33484,4.598,2284.90674,-3.160,
1206.42627,4.598,2284.99829,-2.160,
1206.51782,4.598,2285.08960,-3.160,
1206.60938,4.598,2285.18115,-3.160,
1206.70093,4.598,2285.27271,-2.160,
1206.79236,4.598,2285.36426,-3.160,
1206.88391,4.598,2285.45581,-3.160,
1206.97546,4.598,2285.54736,-2.160,
1207.06702,4.598,2285.63892,-2.160,
1207.15845,3.598,2285.73022,-2.160,
1207.25000,4.598,2285.82178,-2.160,
1207.34155,3.598,2285.91333,-2.160,
1207.43311,3.598,2286.00488,-2.160,
1207.52454,4.598,2286.09644,-2.160,
1207.61609,3.598,2286.18799,-2.160,
1207.70764,4.598,2286.27954,-2.160,
1207.79907,3.598,2286.37109,-2.160,
1207.89063,4.598,2286.46240,-2.160,
1207.98218,3.598,2286.55396,-2.160,
1208.07373,4.598,2286.64551,-2.160,
1208.16516,4.598,2286.73706,-1.160,
1208.25671,4.598,2286.82861,-1.160,
1208.34827,4.598,2286.92017,-1.160,
1208.43982,3.598,2287.01172,-1.160,
1208.53125,4.598,2287.10303,-0.160,
1208.62280,4.598,2287.19458,-0.160,
1208.71436,3.598,2287.28613,-0.160,
1208.80591,3.598,2287.37769,-0.160,
1208.89734,4.598,2287.46924,0.840,
1208.98889,4.598,2287.56079,-0.160,
1209.08044,4.598,2287.65234,-0.160,
1209.17200,4.598,2287.74390,-0.160,
1209.26343,4.598,2287.83521,-0.160,
1209.35498,4.598,2287.92676,-0.160,
1209.44653,4.598,2288.01831,-0.160,
1209.53796,4.598,2288.10986,-0.160,
1209.62952,4.598,2288.20142,-0.160,
1209.72107,4.598,2288.29297,-1.160,
1209.81262,4.598,2288.38452,-1.160,
1209.90405,4.598,2288.47607,-1.160,
1209.99561,3.598,2288.56738,-1.160,
1210.08716,4.598,2288.65894,-1.160,
1210.17871,3.598,2288.75049,-1.160,
1210.27014,3.598,2288.84204,-2.160,
1210.36169,4.598,2288.93359,-2.160,
1210.45325,4.598,2289.02515,-1.160,
1210.54480,4.598,2289.11670,-2.160,
1210.63623,3.598,2289.20801,-1.160,
1210.72778,3.598,2289.29956,-1.160,
1210.81934,3.598,2289.39111,-1.160,
1210.91089,3.598,2289.48267,-2.160,
1211.00232,4.598,2289.57422,-1.160,
1211.09387,4.598,2289.66577,-1.160,
1211.18542,4.598,2289.75732,-2.160,
1211.27686,4.598,2289.84888,-2.160,
1211.36841,4.598,2289.94019,-1.160,
1211.45996,4.598,2290.03174,-2.160,
1211.55151,4.598,2290.12329,-1.160,
1211.64294,4.598,2290.21484,-1.160,
1211.73450,4.598,2290.30640,-2.160,
1211.82605,4.598,2290.39795,-2.160,
1211.91760,4.598,2290.48950,-1.160,
1212.00903,4.598,2290.58105,-2.160,
1212.10059,4.598,2290.67236,-1.160,
1212.19214,4.598,2290.76392,-2.160,
1212.28369,4.598,2290.85547,-1.160,
1212.37512,4.598,2290.94702,-2.160,
1212.46667,4.598,2291.03857,-1.160,
1212.55823,4.598,2291.13013,-0.160,
1212.64978,3.598,2291.22168,-1.160,
1212.74121,3.598,2291.31299,-2.160,
1212.83276,4.598,2291.40454,-1.160,
1212.92432,4.598,2291.49609,-1.160,
1213.01587,4.598,2291.58765,-1.160,
1213.10730,4.598,2291.67920,-2.160,
1213.19885,4.598,2291.77075,-1.160,
1213.29041,4.598,2291.86230,-2.160,
1213.38184,5.598,2291.95386,-1.160,
1213.47339,5.598,2292.04517,-1.160,
1213.56494,4.598,2292.13672,-1.160,
1213.65649,4.598,2292.22827,-2.160,
1213.74792,4.598,2292.31982,-2.160,
1213.83948,4.598,2292.41138,-1.160,
1213.93103,4.598,2292.50293,-2.160,
1214.02258,4.598,2292.59448,-1.160,
1214.11401,4.598,2292.68579,-1.160,
1214.20557,4.598,2292.77734,-1.160,
1214.29712,4.598,2292.86890,-2.160,
1214.38867,4.598,2292.96045,-1.160,
1214.48010,4.598,2293.05200,-2.160,
1214.57166,4.598,2293.14355,-1.160,
1214.66321,4.598,2293.23511,-1.160,
1214.75476,5.598,2293.32666,-1.160,
1214.84619,5.598,2293.41797,-2.160,
1214.93774,4.598,2293.50952,-1.160,
1215.02930,4.598,2293.60107,-2.160,
1215.12073,4.598,2293.69263,-1.160,
1215.21228,4.598,2293.78418,-2.160,
1215.30383,4.598,2293.87573,-1.160,
1215.39539,4.598,2293.96729,-2.160,
1215.48682,4.598,2294.05884,-1.160,
1215.57837,4.598,2294.15015,-1.160,
1215.66992,4.598,2294.24170,-1.160,
1215.76147,3.598,2294.33325,-2.160,
1215.85291,4.598,2294.42480,-1.160,
1215.94446,4.598,2294.51636,-1.160,
1216.03601,4.598,2294.60791,-1.160,
1216.12756,4.598,2294.69946,-1.160,
1216.21899,4.598,2294.79077,-1.160,
1216.31055,5.598,2294.88232,-1.160,
1216.40210,4.598,2294.97388,-2.160,
1216.49365,4.598,2295.06543,-1.160,
1216.58508,4.598,2295.15698,-1.160,
1216.67664,4.598,2295.24854,-1.160,
1216.76819,4.598,2295.34009,-1.160,
1216.85974,4.598,2295.43164,-1.160,
1216.95117,4.598,2295.52295,-0.160,
1217.04272,5.598,2295.61450,-1.160,
1217.13428,5.598,2295.70605,-1.160,
1217.22571,4.598,2295.79761,-1.160,
1217.31726,4.598,2295.88916,-1.160,
1217.40881,4.598,2295.98071,-1.160,
1217.50037,4.598,2296.07227,-1.160,
1217.59180,4.598,2296.16382,-1.160,
1217.68335,4.598,2296.25513,-2.160,
1217.77490,5.598,2296.34668,-1.160,
1217.86646,4.598,2296.43823,-2.160,
1217.95789,4.598,2296.52979,-2.160,
1218.04944,4.598,2296.62134,-1.160,
1218.14099,4.598,2296.71289,-1.160,
1218.23254,4.598,2296.80444,-2.160,
1218.32397,4.598,2296.89575,-2.160,
1218.41553,4.598,2296.98730,-1.160,
1218.50708,4.598,2297.07886,-2.160,
1218.59863,4.598,2297.17041,-1.160,
1218.69006,5.598,2297.26196,-1.160,
1218.78162,4.598,2297.35352,-2.160,
1218.87317,4.598,2297.44507,-1.160,
1218.96460,4.598,2297.53662,-1.160,
1219.05615,4.598,2297.62793,-1.160,
1219.14771,4.598,2297.71948,-2.160,
1219.23926,4.598,2297.81104,-2.160,
1219.33069,5.598,2297.90259,-1.160,
1219.42224,4.598,2297.99414,-1.160,
1219.51379,5.598,2298.08569,-2.160,
1219.60535,4.598,2298.17725,-1.160,
1219.69678,5.598,2298.26855,-2.160,
1219.78833,4.598,2298.36011,-1.160,
1219.87988,4.598,2298.45166,-1.160,
1219.97144,4.598,2298.54321,-1.160,
1220.06287,4.598,2298.63477,-2.160,
1220.15442,4.598,2298.72632,-1.160,
1220.24597,5.598,2298.81787,-1.160,
1220.33752,4.598,2298.90942,-1.160,
1220.42896,4.598,2299.00073,-1.160,
1220.52051,4.598,2299.09229,-1.160,
1220.61206,4.598,2299.18384,-1.160,
1220.70349,4.598,2299.27539,-2.160,
1220.79504,4.598,2299.36694,-1.160,
1220.88660,5.598,2299.45850,-1.160,
1220.97815,4.598,2299.55005,-1.160,
1221.06958,4.598,2299.64160,-1.160,
1221.16113,5.598,2299.73291,-1.160,
1221.25269,4.598,2299.82446,-2.160,
1221.34424,4.598,2299.91602,-1.160,
1221.43567,4.598,2300.00757,-1.160,
1221.52722,4.598,2300.09912,-2.160,
1221.61877,4.598,2300.19067,-2.160,
1221.71033,4.598,2300.28223,-1.160,
1221.80176,4.598,2300.37354,-1.160,
1221.89331,5.598,2300.46509,-2.160,
1221.98486,4.598,2300.55664,-2.160,
1222.07642,5.598,2300.64819,-2.160,
1222.16785,5.598,2300.73975,-2.160,
1222.25940,4.598,2300.83130,-1.160,
1222.35095,5.598,2300.92285,-2.160,
1222.44250,4.598,2301.01440,-2.160,
1222.53394,4.598,2301.10571,-2.160,
1222.62549,4.598,2301.19727,-1.160,
1222.71704,5.598,2301.28882,-1.160,
1222.80847,5.598,2301.38037,-1.160,
1222.90002,4.598,2301.47192,-2.160,
1222.99158,5.598,2301.56348,-1.160,
1223.08313,4.598,2301.65503,-1.160,
1223.17456,4.598,2301.74658,-2.160,
1223.26611,4.598,2301.83789,-1.160,
1223.35767,4.598,2301.92944,-2.160,
1223.44922,4.598,2302.02100,-1.160,
1223.54065,4.598,2302.11255,-1.160,
1223.63220,5.598,2302.20410,-2.160,
1223.72375,4.598,2302.29565,-2.160,
1223.81531,4.598,2302.38721,-2.160,
1223.90674,5.598,2302.47852,-1.160,
1223.99829,4.598,2302.57007,-2.160,
1224.08984,5.598,2302.66162,-2.160,
1224.18140,4.598,2302.75317,-2.160,
1224.27283,5.598,2302.84473,-2.160,
1224.36438,5.598,2302.93628,-3.160,
1224.45593,4.598,2303.02783,-3.160,
1224.54736,4.598,2303.11938,-2.160,
1224.63892,4.598,2303.21069,-2.160,
1224.73047,4.598,2303.30225,-2.160,
1224.82202,4.598,2303.39380,-2.160,
1224.91345,4.598,2303.48535,-1.160,
1225.00500,4.598,2303.57690,-2.160,
1225.09656,5.598,2303.66846,-2.160,
1225.18811,5.598,2303.76001,-2.160,
1225.27954,4.598,2303.85132,-2.160,
1225.37109,5.598,2303.94287,-2.160,
1225.46265,5.598,2304.03442,-1.160,
1225.55420,5.598,2304.12598,-1.160,
1225.64563,4.598,2304.21753,-2.160,
1225.73718,5.598,2304.30908,-1.160,
1225.82874,5.598,2304.40063,-1.160,
1225.92029,4.598,2304.49219,-1.160,
1226.01172,4.598,2304.58350,-1.160,
1226.10327,5.598,2304.67505,-1.160,
1226.19482,4.598,2304.76660,-2.160,
1226.28638,4.598,2304.85815,-1.160,
1226.37781,5.598,2304.94971,-1.160,
1226.46936,4.598,2305.04126,-1.160,
1226.56091,5.598,2305.13281,-2.160,
1226.65234,5.598,2305.22437,-2.160,
1226.74390,5.598,2305.31567,-2.160,
1226.83545,4.598,2305.40723,-2.160,
1226.92700,4.598,2305.49878,-2.160,
1227.01843,4.598,2305.59033,-2.160,
1227.10999,4.598,2305.68188,-2.160,
1227.20154,4.598,2305.77344,-2.160,
1227.29309,5.598,2305.86499,-2.160,
1227.38452,4.598,2305.95630,-2.160,
1227.47607,4.598,2306.04785,-2.160,
1227.56763,4.598,2306.13940,-2.160,
1227.65918,5.598,2306.23096,-1.160,
1227.75061,4.598,2306.32251,-2.160,
1227.84216,5.598,2306.41406,-1.160,
1227.93372,4.598,2306.50562,-1.160,
1228.02527,5.598,2306.59717,-2.160,
1228.11670,4.598,2306.68848,-1.160,
1228.20825,5.598,2306.78003,-2.160,
1228.29980,4.598,2306.87158,-1.160,
1228.39124,4.598,2306.96313,-2.160,
1228.48279,5.598,2307.05469,-2.160,
1228.57434,5.598,2307.14624,-1.160,
1228.66589,5.598,2307.23779,-1.160,
1228.75732,5.598,2307.32935,-1.160,
1228.84888,4.598,2307.42065,-1.160,
1228.94043,4.598,2307.51221,-1.160,
1229.03198,5.598,2307.60376,-1.160,
1229.12341,4.598,2307.69531,-1.160,
1229.21497,5.598,2307.78687,-1.160,
1229.30652,4.598,2307.87842,-1.160,
1229.39807,4.598,2307.96997,-1.160,
1229.48950,4.598,2308.06128,-1.160,
1229.58105,5.598,2308.15283,-1.160,
1229.67261,5.598,2308.24438,-2.160,
1229.76416,4.598,2308.33594,-1.160,
1229.85559,4.598,2308.42749,-2.160,
1229.94714,4.598,2308.51904,-1.160,
1230.03870,4.598,2308.61060,-1.160,
1230.13013,4.598,2308.70215,-1.160,
1230.22168,4.598,2308.79346,-2.160,
1230.31323,4.598,2308.88501,-1.160,
1230.40479,4.598,2308.97656,-1.160,
1230.49622,4.598,2309.06812,-1.160,
1230.58777,4.598,2309.15967,-2.160,
1230.67932,4.598,2309.25122,-1.160,
1230.77087,4.598,2309.34277,-1.160,
1230.86230,4.598,2309.43433,-2.160,
1230.95386,5.598,2309.52563,-1.160,
1231.04541,4.598,2309.61719,-1.160,
1231.13696,4.598,2309.70874,-2.160,
1231.22839,4.598,2309.80029,-1.160,
1231.31995,4.598,2309.89185,-2.160,
1231.41150,4.598,2309.98340,-2.160,
1231.50305,4.598,2310.07495,-2.160,
1231.59448,4.598,2310.16626,-1.160,
1231.68604,4.598,2310.25781,-2.160,
1231.77759,4.598,2310.34937,-2.160,
1231.86914,4.598,2310.44092,-1.160,
1231.96057,4.598,2310.53247,-1.160,
1232.05212,4.598,2310.62402,-2.160,
1232.14368,4.598,2310.71558,-2.160,
1232.23511,4.598,2310.80713,-1.160,
1232.32666,4.598,2310.89844,-2.160,
1232.41821,5.598,2310.98999,-2.160,
1232.50977,5.598,2311.08154,-1.160,
1232.60120,4.598,2311.17310,-1.160,
1232.69275,4.598,2311.26465,-1.160,
1232.78430,4.598,2311.35620,-1.160,
1232.87585,5.598,2311.44775,-1.160,
1232.96729,4.598,2311.53906,-1.160,
1233.05884,5.598,2311.63062,-1.160,
1233.15039,5.598,2311.72217,-1.160,
1233.24194,4.598,2311.81372,-2.160,
1233.33337,5.598,2311.90527,-1.160,
1233.42493,4.598,2311.99683,-1.160,
1233.51648,5.598,2312.08838,-2.160,
1233.60803,4.598,2312.17993,-2.160,
1233.69946,4.598,2312.27124,-1.160,
1233.79102,5.598,2312.36279,-2.160,
1233.88257,5.598,2312.45435,-2.160,
1233.97400,5.598,2312.54590,-2.160,
1234.06555,5.598,2312.63745,-1.160,
1234.15710,5.598,2312.72900,-2.160,
1234.24866,5.598,2312.82056,-2.160,
1234.34009,5.598,2312.91211,-1.160,
1234.43164,5.598,2313.00342,-1.160,
1234.52319,5.598,2313.09497,-1.160,
1234.61475,5.598,2313.18652,-1.160,
1234.70618,4.598,2313.27808,-1.160,
1234.79773,4.598,2313.36963,-1.160,
1234.88928,4.598,2313.46118,-2.160,
1234.98083,4.598,2313.55273,-1.160,
1235.07227,4.598,2313.64404,-1.160,
1235.16382,4.598,2313.73560,-1.160,
1235.25537,4.598,2313.82715,-0.160,
1235.34692,5.598,2313.91870,-1.160,
1235.43835,4.598,2314.01025,-1.160,
1235.52991,4.598,2314.10181,-1.160,
1235.62146,5.598,2314.19336,-1.160,
1235.71301,4.598,2314.28491,-1.160,
1235.80444,4.598,2314.37622,-1.160,
1235.89600,5.598,2314.46777,-2.160,
1235.98755,4.598,2314.55933,-1.160,
1236.07898,5.598,2314.65088,-2.160,
1236.17053,4.598,2314.74243,-2.160,
1236.26208,4.598,2314.83398,-1.160,
1236.35364,4.598,2314.92554,-2.160,
1236.44507,5.598,2315.01709,-1.160,
1236.53662,5.598,2315.10840,-1.160,
1236.62817,5.598,2315.19995,-1.160,
1236.71973,5.598,2315.29150,-1.160,
1236.81116,5.598,2315.38306,-1.160,
1236.90271,6.598,2315.47461,-1.160,
1236.99426,6.598,2315.56616,-1.160,
1237.08582,6.598,2315.65771,-1.160,
1237.17725,6.598,2315.74902,-1.160,
1237.26880,6.598,2315.84058,-1.160,
1237.36035,6.598,2315.93213,-1.160,
1237.45190,7.598,2316.02368,-0.160,
1237.54333,6.598,2316.11523,-1.160,
1237.63489,6.598,2316.20679,-1.160,
1237.72644,5.598,2316.29834,-1.160,
1237.81787,5.598,2316.38989,-2.160,
1237.90942,5.598,2316.48120,-1.160,
1238.00098,6.598,2316.57275,-1.160,
1238.09253,5.598,2316.66431,-1.160,
1238.18396,5.598,2316.75586,-2.160,
1238.27551,5.598,2316.84741,-1.160,
1238.36707,5.598,2316.93896,-1.160,
1238.45862,5.598,2317.03052,-1.160,
1238.55005,5.598,2317.12183,-1.160,
1238.64160,5.598,2317.21338,-1.160,
1238.73315,4.598,2317.30493,-1.160,
1238.82471,5.598,2317.39648,-1.160,
1238.91614,5.598,2317.48804,-1.160,
1239.00769,5.598,2317.57959,-1.160,
1239.09924,5.598,2317.67114,-1.160,
1239.19080,5.598,2317.76270,-1.160,
1239.28223,5.598,2317.85400,-1.160,
1239.37378,5.598,2317.94556,-1.160,
1239.46533,5.598,2318.03711,-1.160,
1239.55676,5.598,2318.12866,-1.160,
1239.64832,5.598,2318.22021,-1.160,
1239.73987,5.598,2318.31177,-1.160,
1239.83142,6.598,2318.40332,-1.160,
1239.92285,5.598,2318.49487,-1.160,
1240.01440,5.598,2318.58618,-2.160,
1240.10596,6.598,2318.67773,-1.160,
1240.19751,5.598,2318.76929,-1.160,
1240.28894,5.598,2318.86084,-1.160,
1240.38049,5.598,2318.95239,-1.160,
1240.47205,5.598,2319.04395,-1.160,
1240.56360,5.598,2319.13550,-1.160,
1240.65503,5.598,2319.22681,-1.160,
1240.74658,5.598,2319.31836,-1.160,
1240.83813,5.598,2319.40991,-1.160,
1240.92969,5.598,2319.50146,-2.160,
1241.02112,5.598,2319.59302,-1.160,
1241.11267,5.598,2319.68457,-1.160,
1241.20422,5.598,2319.77612,-1.160,
1241.29578,5.598,2319.86768,-1.160,
1241.38721,5.598,2319.95898,-1.160,
1241.47876,6.598,2320.05054,-1.160,
1241.57031,5.598,2320.14209,-1.160,
1241.66174,5.598,2320.23364,-1.160,
1241.75330,5.598,2320.32520,-1.160,
1241.84485,5.598,2320.41675,-1.160,
1241.93640,5.598,2320.50830,-1.160,
1242.02783,5.598,2320.59985,-1.160,
1242.11938,5.598,2320.69116,-1.160,
1242.21094,5.598,2320.78271,-1.160,
1242.30249,5.598,2320.87427,-1.160,
1242.39392,5.598,2320.96582,-1.160,
1242.48547,4.598,2321.05737,-1.160,
1242.57703,5.598,2321.14893,-1.160,
1242.66858,6.598,2321.24048,-1.160,
1242.76001,5.598,2321.33179,-1.160,
1242.85156,5.598,2321.42334,-1.160,
1242.94312,6.598,2321.51489,-1.160,
1243.03467,5.598,2321.60645,-1.160,
1243.12610,5.598,2321.69800,-1.160,
1243.21765,6.598,2321.78955,-0.160,
1243.30920,5.598,2321.88110,-0.160,
1243.40063,5.598,2321.97266,-1.160,
1243.49219,5.598,2322.06396,-1.160,
1243.58374,5.598,2322.15552,-0.160,
1243.67529,5.598,2322.24707,-1.160,
1243.76672,5.598,2322.33862,-0.160,
1243.85828,5.598,2322.43018,-0.160,
1243.94983,5.598,2322.52173,-0.160,
1244.04138,5.598,2322.61328,-1.160,
1244.13281,5.598,2322.70459,-0.160,
1244.22437,5.598,2322.79614,-1.160,
1244.31592,5.598,2322.88770,-0.160,
1244.40747,5.598,2322.97925,-0.160,
1244.49890,5.598,2323.07080,-1.160,
1244.59045,5.598,2323.16235,-1.160,
1244.68201,6.598,2323.25391,-1.160,
1244.77356,5.598,2323.34546,-1.160,
1244.86499,5.598,2323.43677,-2.160,
1244.95654,5.598,2323.52832,-2.160,
1245.04810,5.598,2323.61987,-2.160,
1245.13965,5.598,2323.71143,-2.160,
1245.23108,5.598,2323.80298,-3.160,
1245.32263,5.598,2323.89453,-2.160,
1245.41418,5.598,2323.98608,-1.160,
1245.50562,5.598,2324.07764,-2.160,
1245.59717,6.598,2324.16895,-2.160,
1245.68872,5.598,2324.26050,-1.160,
1245.78027,5.598,2324.35205,-1.160,
1245.87170,5.598,2324.44360,-2.160,
1245.96326,5.598,2324.53516,-1.160,
1246.05481,5.598,2324.62671,-1.160,
1246.14636,5.598,2324.71826,-1.160,
1246.23779,5.598,2324.80957,-1.160,
1246.32935,5.598,2324.90112,-1.160,
1246.42090,5.598,2324.99268,-1.160,
1246.51245,5.598,2325.08423,-0.160,
1246.60388,5.598,2325.17578,-1.160,
1246.69543,5.598,2325.26733,-1.160,
1246.78699,5.598,2325.35889,-1.160,
1246.87854,5.598,2325.45044,-1.160,
1246.96997,5.598,2325.54175,-1.160,
1247.06152,6.598,2325.63330,-1.160,
1247.15308,5.598,2325.72485,-1.160,
1247.24451,5.598,2325.81641,-1.160,
1247.33606,5.598,2325.90796,-1.160,
1247.42761,5.598,2325.99951,-1.160,
1247.51917,5.598,2326.09106,-1.160,
1247.61060,5.598,2326.18262,-1.160,
1247.70215,5.598,2326.27393,-1.160,
1247.79370,5.598,2326.36548,-1.160,
1247.88525,5.598,2326.45703,-1.160,
1247.97668,5.598,2326.54858,-1.160,
1248.06824,5.598,2326.64014,-1.160,
1248.15979,5.598,2326.73169,-0.160,
1248.25134,5.598,2326.82324,-0.160,
1248.34277,5.598,2326.91455,-1.160,
1248.43433,5.598,2327.00610,-0.160,
1248.52588,6.598,2327.09766,-1.160,
1248.61743,5.598,2327.18921,-1.160,
1248.70886,6.598,2327.28076,-0.160,
1248.80042,6.598,2327.37231,-1.160,
1248.89197,5.598,2327.46387,-1.160,
1248.98340,5.598,2327.55542,-1.160,
1249.07495,6.598,2327.64673,-1.160,
1249.16650,5.598,2327.73828,-0.160,
1249.25806,5.598,2327.82983,-1.160,
1249.34949,6.598,2327.92139,-1.160,
1249.44104,5.598,2328.01294,-1.160,
1249.53259,5.598,2328.10449,-1.160,
1249.62415,5.598,2328.19604,-1.160,
1249.71558,6.598,2328.28760,-1.160,
1249.80713,5.598,2328.37891,-1.160,
1249.89868,5.598,2328.47046,-1.160,
1249.99023,6.598,2328.56201,-0.160,
1250.08167,6.598,2328.65356,-1.160,
1250.17322,5.598,2328.74512,-1.160,
1250.26477,6.598,2328.83667,-1.160,
1250.35632,5.598,2328.92822,-0.160,
1250.44775,5.598,2329.01953,-0.160,
1250.53931,6.598,2329.11108,-1.160,
1250.63086,6.598,2329.20264,-1.160,
1250.72241,5.598,2329.29419,-1.160,
1250.81384,5.598,2329.38574,-1.160,
1250.90540,5.598,2329.47729,-0.160,
1250.99695,5.598,2329.56885,-1.160,
1251.08838,5.598,2329.66040,-1.160,
1251.17993,5.598,2329.75171,-1.160,
1251.27148,5.598,2329.84326,-0.160,
1251.36304,5.598,2329.93481,-1.160,
1251.45447,6.598,2330.02637,-0.160,
1251.54602,5.598,2330.11792,-0.160,
1251.63757,5.598,2330.20947,-0.160,
1251.72913,5.598,2330.30103,-0.160,
1251.82056,6.598,2330.39233,-0.160,
1251.91211,5.598,2330.48389,-0.160,
1252.00366,5.598,2330.57544,-0.160,
1252.09521,5.598,2330.66699,0.840,
1252.18665,6.598,2330.75854,-0.160,
1252.27820,5.598,2330.85010,-1.160,
1252.36975,5.598,2330.94165,-1.160,
1252.46130,5.598,2331.03320,-0.160,
1252.55273,5.598,2331.12451,-0.160,
1252.64429,5.598,2331.21606,-1.160,
1252.73584,5.598,2331.30762,-1.160,
1252.82727,5.598,2331.39917,-0.160,
1252.91882,5.598,2331.49072,-1.160,
1253.01038,5.598,2331.58228,-1.160,
1253.10193,5.598,2331.67383,-1.160,
1253.19336,5.598,2331.76538,-0.160,
1253.28491,5.598,2331.85669,-1.160,
1253.37646,5.598,2331.94824,-1.160,
1253.46802,5.598,2332.03979,-0.160,
1253.55945,5.598,2332.13135,-1.160,
1253.65100,5.598,2332.22290,-0.160,
1253.74255,5.598,2332.31445,-0.160,
1253.83411,5.598,2332.40601,-1.160,
1253.92554,5.598,2332.49731,-1.160,
1254.01709,5.598,2332.58887,-1.160,
1254.10864,5.598,2332.68042,-1.160,
1254.20020,6.598,2332.77197,-1.160,
1254.29163,6.598,2332.86353,-1.160,
1254.38318,6.598,2332.95508,-1.160,
1254.47473,6.598,2333.04663,-1.160,
1254.56628,5.598,2333.13818,-1.160,
1254.65771,6.598,2333.22949,-1.160,
1254.74927,5.598,2333.32104,-1.160,
1254.84082,6.598,2333.41260,-1.160,
1254.93225,6.598,2333.50415,-0.160,
1255.02380,6.598,2333.59570,-0.160,
1255.11536,6.598,2333.68726,-1.160,
1255.20691,6.598,2333.77881,-0.160,
1255.29834,6.598,2333.87036,-1.160,
1255.38989,7.598,2333.96167,-1.160,
1255.48145,7.598,2334.05322,-1.160,
1255.57300,7.598,2334.14478,-1.160,
1255.66443,7.598,2334.23633,-0.160,
1255.75598,7.598,2334.32788,-1.160,
1255.84753,8.598,2334.41943,-0.160,
1255.93909,7.598,2334.51099,-1.160,
1256.03052,7.598,2334.60229,-1.160,
1256.12207,7.598,2334.69385,-1.160,
1256.21362,7.598,2334.78540,-1.160,
1256.30518,6.598,2334.87695,-1.160,
1256.39661,7.598,2334.96851,-0.160,
1256.48816,6.598,2335.06006,-0.160,
1256.57971,6.598,2335.15161,-1.160,
1256.67114,6.598,2335.24316,-0.160,
1256.76270,6.598,2335.33447,-0.160,
1256.85425,6.598,2335.42603,-1.160,
1256.94580,6.598,2335.51758,-1.160,
1257.03723,6.598,2335.60913,-0.160,
1257.12878,5.598,2335.70068,-1.160,
1257.22034,5.598,2335.79224,-0.160,
1257.31189,6.598,2335.88379,-1.160,
1257.40332,5.598,2335.97510,-0.160,
1257.49487,5.598,2336.06665,-1.160,
1257.58643,6.598,2336.15820,-0.160,
1257.67798,5.598,2336.24976,-0.160,
1257.76941,5.598,2336.34131,-1.160,
1257.86096,6.598,2336.43286,-1.160,
1257.95251,5.598,2336.52441,-0.160,
1258.04407,6.598,2336.61597,-0.160,
1258.13550,5.598,2336.70728,-1.160,
1258.22705,5.598,2336.79883,-1.160,
1258.31860,5.598,2336.89038,-1.160,
1258.41003,5.598,2336.98193,-1.160,
1258.50159,5.598,2337.07349,-1.160,
1258.59314,5.598,2337.16504,-0.160,
1258.68469,6.598,2337.25659,-1.160,
1258.77612,6.598,2337.34814,-1.160,
1258.86768,6.598,2337.43945,-1.160,
1258.95923,5.598,2337.53101,-0.160,
1259.05078,5.598,2337.62256,-1.160,
1259.14221,5.598,2337.71411,-1.160,
1259.23376,6.598,2337.80566,-1.160,
1259.32532,5.598,2337.89722,-1.160,
1259.41687,6.598,2337.98877,-0.160,
1259.50830,6.598,2338.08008,-1.160,
1259.59985,6.598,2338.17163,-1.160,
1259.69141,6.598,2338.26318,-0.160,
1259.78296,6.598,2338.35474,-0.160,
1259.87439,6.598,2338.44629,-0.160,
1259.96594,5.598,2338.53784,-1.160,
1260.05750,6.598,2338.62939,-1.160,
1260.14905,6.598,2338.72095,-0.160,
1260.24048,6.598,2338.81226,-1.160,
1260.33203,6.598,2338.90381,-1.160,
1260.42358,6.598,2338.99536,-0.160,
1260.51501,6.598,2339.08691,-1.160,
1260.60657,6.598,2339.17847,-1.160,
1260.69812,6.598,2339.27002,-2.160,
1260.78967,6.598,2339.36157,-2.160,
1260.88110,6.598,2339.45313,-1.160,
1260.97266,6.598,2339.54443,-2.160,
1261.06421,5.598,2339.63599,-1.160,
1261.15576,6.598,2339.72754,-2.160,
1261.24719,5.598,2339.81909,-1.160,
1261.33875,6.598,2339.91064,-1.160,
1261.43030,6.598,2340.00220,-1.160,
1261.52185,5.598,2340.09375,-1.160,
1261.61328,6.598,2340.18506,-0.160,
1261.70483,6.598,2340.27661,-1.160,
1261.79639,6.598,2340.36816,-1.160,
1261.88794,6.598,2340.45972,-1.160,
1261.97937,6.598,2340.55127,-1.160,
1262.07092,6.598,2340.64282,-1.160,
1262.16248,5.598,2340.73438,-1.160,
1262.25391,6.598,2340.82593,-0.160,
1262.34546,6.598,2340.91724,-0.160,
1262.43701,6.598,2341.00879,-1.160,
1262.52856,6.598,2341.10034,-0.160,
1262.62000,6.598,2341.19189,-1.160,
1262.71155,5.598,2341.28345,-0.160,
1262.80310,6.598,2341.37500,-0.160,
1262.89465,6.598,2341.46655,0.840,
1262.98608,5.598,2341.55786,0.840,
1263.07764,6.598,2341.64941,-0.160,
1263.16919,7.598,2341.74097,-0.160,
1263.26074,6.598,2341.83252,-0.160,
1263.35217,5.598,2341.92407,-0.160,
1263.44373,6.598,2342.01563,-0.160,
1263.53528,6.598,2342.10718,-0.160,
1263.62683,6.598,2342.19873,-1.160,
1263.71826,6.598,2342.29004,-0.160,
1263.80981,6.598,2342.38159,-0.160,
1263.90137,6.598,2342.47314,-0.160,
1263.99292,6.598,2342.56470,-1.160,
1264.08435,6.598,2342.65625,-1.160,
1264.17590,6.598,2342.74780,-1.160,
1264.26746,6.598,2342.83936,-0.160,
1264.35889,6.598,2342.93091,-1.160,
1264.45044,6.598,2343.02222,-1.160,
1264.54199,6.598,2343.11377,-1.160,
1264.63354,6.598,2343.20532,-1.160,
1264.72498,6.598,2343.29688,-1.160,
1264.81653,6.598,2343.38843,-1.160,
1264.90808,6.598,2343.47998,-1.160,
1264.99963,6.598,2343.57153,-0.160,
1265.09106,6.598,2343.66284,-1.160,
1265.18262,6.598,2343.75439,-1.160,
1265.27417,6.598,2343.84595,-0.160,
1265.36572,6.598,2343.93750,-0.160,
1265.45715,6.598,2344.02905,-0.160,
1265.54871,6.598,2344.12061,-0.160,
1265.64026,6.598,2344.21216,-0.160,
1265.73181,6.598,2344.30371,-0.160,
1265.82324,6.598,2344.39502,-1.160,
1265.91479,6.598,2344.48657,-0.160,
1266.00635,6.598,2344.57813,-1.160,
1266.09778,6.598,2344.66968,-0.160,
1266.18933,6.598,2344.76123,-0.160,
1266.28088,7.598,2344.85278,-0.160,
1266.37244,6.598,2344.94434,-0.160,
1266.46387,6.598,2345.03589,-1.160,
1266.55542,6.598,2345.12720,-0.160,
1266.64697,6.598,2345.21875,-1.160,
1266.73853,6.598,2345.31030,-0.160,
1266.82996,6.598,2345.40186,-1.160,
1266.92151,6.598,2345.49341,-0.160,
1267.01306,6.598,2345.58496,-0.160,
1267.10461,6.598,2345.67651,-0.160,
1267.19604,7.598,2345.76782,-0.160,
1267.28760,7.598,2345.85938,-0.160,
1267.37915,6.598,2345.95093,-1.160,
1267.47070,6.598,2346.04248,-0.160,
1267.56213,7.598,2346.13403,-1.160,
1267.65369,6.598,2346.22559,-1.160,
1267.74524,6.598,2346.31714,-0.160,
1267.83667,6.598,2346.40869,-0.160,
1267.92822,6.598,2346.50000,-0.160,
1268.01978,6.598,2346.59155,-0.160,
1268.11133,7.598,2346.68311,-0.160,
1268.20276,6.598,2346.77466,-0.160,
1268.29431,6.598,2346.86621,-1.160,
1268.38586,7.598,2346.95776,-0.160,
1268.47742,6.598,2347.04932,-0.160,
1268.56885,6.598,2347.14087,-1.160,
1268.66040,6.598,2347.23218,-0.160,
1268.75195,6.598,2347.32373,-1.160,
1268.84351,6.598,2347.41528,-0.160,
1268.93494,7.598,2347.50684,-0.160,
1269.02649,7.598,2347.59839,-1.160,
1269.11804,6.598,2347.68994,-1.160,
1269.20959,6.598,2347.78149,-1.160,
1269.30103,7.598,2347.87280,-0.160,
1269.39258,6.598,2347.96436,-0.160,
1269.48413,6.598,2348.05591,-1.160,
1269.57568,6.598,2348.14746,-0.160,
1269.66711,7.598,2348.23901,-0.160,
1269.75867,6.598,2348.33057,-1.160,
1269.85022,7.598,2348.42212,-1.160,
1269.94165,6.598,2348.51367,-0.160,
1270.03320,6.598,2348.60498,-0.160,
1270.12476,6.598,2348.69653,-0.160,
1270.21631,7.598,2348.78809,-0.160,
1270.30774,6.598,2348.87964,-0.160,
1270.39929,6.598,2348.97119,-1.160,
1270.49084,7.598,2349.06274,-0.160,
1270.58240,6.598,2349.15430,-0.160,
1270.67383,7.598,2349.24561,-1.160,
1270.76538,7.598,2349.33716,-0.160,
1270.85693,6.598,2349.42871,-0.160,
1270.94849,7.598,2349.52026,-1.160,
1271.03992,7.598,2349.61182,-1.160,
1271.13147,6.598,2349.70337,-0.160,
1271.22302,7.598,2349.79492,-1.160,
1271.31458,6.598,2349.88647,-0.160,
1271.40601,7.598,2349.97778,-0.160,
1271.49756,7.598,2350.06934,-0.160,
1271.58911,7.598,2350.16089,-1.160,
1271.68054,6.598,2350.25244,-0.160,
1271.77209,6.598,2350.34399,-0.160,
1271.86365,5.598,2350.43555,-0.160,
1271.95520,6.598,2350.52710,-0.160,
1272.04663,6.598,2350.61865,-0.160,
1272.13818,6.598,2350.70996,-0.160,
1272.22974,5.598,2350.80151,-0.160,
1272.32129,6.598,2350.89307,-1.160,
1272.41272,6.598,2350.98462,-0.160,
1272.50427,6.598,2351.07617,-0.160,
1272.59583,6.598,2351.16772,-0.160,
1272.68738,7.598,2351.25928,-0.160,
1272.77881,6.598,2351.35059,-0.160,
1272.87036,6.598,2351.44214,-0.160,
1272.96191,6.598,2351.53369,-1.160,
1273.05347,6.598,2351.62524,-0.160,
1273.14490,6.598,2351.71680,-1.160,
1273.23645,6.598,2351.80835,-1.160,
1273.32800,6.598,2351.89990,-0.160,
1273.41956,7.598,2351.99146,-0.160,
1273.51099,7.598,2352.08276,-0.160,
1273.60254,7.598,2352.17432,-0.160,
1273.69409,7.598,2352.26587,-1.160,
1273.78552,6.598,2352.35742,-1.160,
1273.87708,7.598,2352.44897,-1.160,
1273.96863,7.598,2352.54053,-0.160,
1274.06018,6.598,2352.63208,-0.160,
1274.15161,6.598,2352.72363,-1.160,
1274.24316,6.598,2352.81494,-0.160,
1274.33472,6.598,2352.90649,-0.160,
1274.42627,5.598,2352.99805,-0.160,
1274.51770,5.598,2353.08960,-0.160,
1274.60925,5.598,2353.18115,-0.160,
1274.70081,5.598,2353.27271,-0.160,
1274.79236,5.598,2353.36426,-0.160,
1274.88379,6.598,2353.45557,-0.160,
1274.97534,5.598,2353.54712,-1.160,
1275.06689,6.598,2353.63867,-1.160,
1275.15845,6.598,2353.73022,-0.160,
1275.24988,6.598,2353.82178,-0.160,
1275.34143,6.598,2353.91333,-1.160,
1275.43298,6.598,2354.00488,-0.160,
1275.52441,6.598,2354.09644,-0.160,
1275.61597,6.598,2354.18774,-0.160,
1275.70752,6.598,2354.27930,-0.160,
1275.79907,7.598,2354.37085,-0.160,
1275.89050,6.598,2354.46240,-1.160,
1275.98206,7.598,2354.55396,-0.160,
1276.07361,6.598,2354.64551,-0.160,
1276.16516,7.598,2354.73706,-0.160,
1276.25659,7.598,2354.82837,-0.160,
1276.34814,8.598,2354.91992,-0.160,
1276.43970,7.598,2355.01147,-0.160,
1276.53125,7.598,2355.10303,-0.160,
1276.62268,6.598,2355.19458,-0.160,
1276.71423,7.598,2355.28613,-0.160,
1276.80579,6.598,2355.37769,-0.160,
1276.89734,7.598,2355.46924,-0.160,
1276.98877,7.598,2355.56055,-0.160,
1277.08032,6.598,2355.65210,-1.160,
1277.17188,6.598,2355.74365,-0.160,
1277.26331,6.598,2355.83521,-0.160,
1277.35486,7.598,2355.92676,-0.160,
1277.44641,7.598,2356.01831,-0.160,
1277.53796,6.598,2356.10986,-0.160,
1277.62939,7.598,2356.20142,-0.160,
1277.72095,6.598,2356.29272,-0.160,
1277.81250,7.598,2356.38428,-0.160,
1277.90405,7.598,2356.47583,-0.160,
1277.99548,6.598,2356.56738,-0.160,
1278.08704,7.598,2356.65894,-0.160,
1278.17859,7.598,2356.75049,-0.160,
1278.27014,7.598,2356.84204,-0.160,
1278.36157,7.598,2356.93335,-0.160,
1278.45313,6.598,2357.02490,-0.160,
1278.54468,7.598,2357.11646,0.840,
1278.63623,6.598,2357.20801,-0.160,
1278.72766,7.598,2357.29956,-0.160,
1278.81921,7.598,2357.39111,-0.160,
1278.91077,6.598,2357.48267,-0.160,
1279.00232,6.598,2357.57422,-0.160,
1279.09375,6.598,2357.66553,-0.160,
1279.18530,6.598,2357.75708,-0.160,
1279.27686,7.598,2357.84863,-0.160,
1279.36829,7.598,2357.94019,-0.160,
1279.45984,7.598,2358.03174,-0.160,
1279.55139,7.598,2358.12329,-1.160,
1279.64294,6.598,2358.21484,-1.160,
1279.73438,6.598,2358.30640,-0.160,
1279.82593,7.598,2358.39771,-1.160,
1279.91748,6.598,2358.48926,-0.160,
1280.00903,6.598,2358.58081,-0.160,
1280.10046,6.598,2358.67236,-0.160,
1280.19202,6.598,2358.76392,-1.160,
1280.28357,6.598,2358.85547,-0.160,
1280.37512,7.598,2358.94702,-0.160,
1280.46655,6.598,2359.03833,-0.160,
1280.55811,6.598,2359.12988,-1.160,
1280.64966,7.598,2359.22144,-0.160,
1280.74121,7.598,2359.31299,-1.160,
1280.83264,6.598,2359.40454,-0.160,
1280.92419,7.598,2359.49609,-1.160,
1281.01575,6.598,2359.58765,-1.160,
1281.10718,7.598,2359.67920,-1.160,
1281.19873,7.598,2359.77051,-1.160,
1281.29028,6.598,2359.86206,-0.160,
1281.38184,6.598,2359.95361,-0.160,
1281.47327,6.598,2360.04517,-0.160,
1281.56482,6.598,2360.13672,-0.160,
1281.65637,6.598,2360.22827,-0.160,
1281.74792,6.598,2360.31982,-1.160,
1281.83936,6.598,2360.41113,-1.160,
1281.93091,6.598,2360.50269,-0.160,
1282.02246,6.598,2360.59424,-1.160,
1282.11401,6.598,2360.68579,-0.160,
1282.20544,7.598,2360.77734,-0.160,
1282.29700,6.598,2360.86890,-0.160,
1282.38855,7.598,2360.96045,-0.160,
1282.48010,7.598,2361.05200,-0.160,
1282.57153,6.598,2361.14331,-1.160,
1282.66309,6.598,2361.23486,-1.160,
1282.75464,6.598,2361.32642,-0.160,
1282.84607,6.598,2361.41797,-0.160,
1282.93762,7.598,2361.50952,-0.160,
1283.02917,6.598,2361.60107,-0.160,
1283.12073,7.598,2361.69263,-0.160,
1283.21216,6.598,2361.78418,-0.160,
1283.30371,6.598,2361.87549,-0.160,
1283.39526,6.598,2361.96704,-0.160,
1283.48682,6.598,2362.05859,-0.160,
1283.57825,7.598,2362.15015,-0.160,
1283.66980,7.598,2362.24170,-1.160,
1283.76135,7.598,2362.33325,-1.160,
1283.85291,6.598,2362.42480,-1.160,
1283.94434,7.598,2362.51611,-1.160,
1284.03589,6.598,2362.60767,-0.160,
1284.12744,6.598,2362.69922,-0.160,
1284.21899,6.598,2362.79077,-0.160,
1284.31042,6.598,2362.88232,-0.160,
1284.40198,7.598,2362.97388,-0.160,
1284.49353,6.598,2363.06543,-0.160,
1284.58508,6.598,2363.15698,-0.160,
1284.67651,7.598,2363.24829,-0.160,
1284.76807,6.598,2363.33984,-1.160,
1284.85962,6.598,2363.43140,-1.160,
1284.95105,7.598,2363.52295,-0.160,
1285.04260,7.598,2363.61450,-0.160,
1285.13416,7.598,2363.70605,-1.160,
1285.22571,7.598,2363.79761,-0.160,
1285.31714,7.598,2363.88916,-0.160,
1285.40869,7.598,2363.98047,-0.160,
1285.50024,7.598,2364.07202,-0.160,
1285.59180,7.598,2364.16357,-0.160,
1285.68323,7.598,2364.25513,-1.160,
1285.77478,7.598,2364.34668,-0.160,
1285.86633,7.598,2364.43823,-0.160,
1285.95789,6.598,2364.52979,-0.160,
1286.04932,6.598,2364.62109,-1.160,
1286.14087,6.598,2364.71265,-0.160,
1286.23242,7.598,2364.80420,-0.160,
1286.32397,6.598,2364.89575,-0.160,
1286.41541,6.598,2364.98730,-0.160,
1286.50696,7.598,2365.07886,-1.160,
1286.59851,7.598,2365.17041,-0.160,
1286.68994,7.598,2365.26196,-0.160,
1286.78149,7.598,2365.35327,-0.160,
1286.87305,7.598,2365.44482,-0.160,
1286.96460,6.598,2365.53638,-1.160,
1287.05603,7.598,2365.62793,-1.160,
1287.14758,7.598,2365.71948,-0.160,
1287.23914,7.598,2365.81104,0.840,
1287.33069,7.598,2365.90259,-1.160,
1287.42212,7.598,2365.99414,-0.160,
1287.51367,7.598,2366.08545,-0.160,
1287.60522,7.598,2366.17700,-0.160,
1287.69678,7.598,2366.26855,-0.160,
1287.78821,6.598,2366.36011,-0.160,
1287.87976,7.598,2366.45166,-0.160,
1287.97131,7.598,2366.54321,-0.160,
1288.06287,7.598,2366.63477,-0.160,
1288.15430,7.598,2366.72607,-0.160,
1288.24585,6.598,2366.81763,-0.160,
1288.33740,7.598,2366.90918,-0.160,
1288.42896,6.598,2367.00073,-0.160,
1288.52039,7.598,2367.09229,-0.160,
1288.61194,7.598,2367.18384,-1.160,
1288.70349,6.598,2367.27539,-0.160,
1288.79492,6.598,2367.36694,-0.160,
1288.88647,6.598,2367.45825,-0.160,
1288.97803,7.598,2367.54980,-0.160,
1289.06958,7.598,2367.64136,-0.160,
1289.16101,6.598,2367.73291,-0.160,
1289.25256,7.598,2367.82446,-0.160,
1289.34412,7.598,2367.91602,-0.160,
1289.43567,7.598,2368.00757,-1.160,
1289.52710,7.598,2368.09888,-0.160,
1289.61865,6.598,2368.19043,-0.160,
1289.71021,6.598,2368.28198,-0.160,
1289.80176,7.598,2368.37354,-0.160,
1289.89319,6.598,2368.46509,-1.160,
1289.98474,6.598,2368.55664,-0.160,
1290.07629,6.598,2368.64819,-0.160,
1290.16785,7.598,2368.73975,-0.160,
1290.25928,6.598,2368.83105,-0.160,
1290.35083,6.598,2368.92261,-0.160,
1290.44238,6.598,2369.01416,-0.160,
1290.53381,6.598,2369.10571,-0.160,
1290.62537,6.598,2369.19727,-0.160,
1290.71692,6.598,2369.28882,-0.160,
1290.80847,6.598,2369.38037,-0.160,
1290.89990,6.598,2369.47192,-0.160,
1290.99146,7.598,2369.56323,-1.160,
1291.08301,6.598,2369.65479,-0.160,
1291.17456,6.598,2369.74634,-0.160,
1291.26599,6.598,2369.83789,-0.160,
1291.35754,7.598,2369.92944,-1.160,
1291.44910,7.598,2370.02100,-0.160,
1291.54065,6.598,2370.11255,-0.160,
1291.63208,7.598,2370.20386,-0.160,
1291.72363,7.598,2370.29541,-0.160,
1291.81519,7.598,2370.38696,-1.160,
1291.90674,6.598,2370.47852,-1.160,
1291.99817,7.598,2370.57007,-0.160,
1292.08972,7.598,2370.66162,-0.160,
1292.18127,6.598,2370.75317,-1.160,
1292.27271,7.598,2370.84473,-0.160,
1292.36426,7.598,2370.93604,-1.160,
1292.45581,7.598,2371.02759,-1.160,
1292.54736,6.598,2371.11914,-1.160,
1292.63879,6.598,2371.21069,-0.160,
1292.73035,6.598,2371.30225,-1.160,
1292.82190,6.598,2371.39380,-1.160,
1292.91345,5.598,2371.48535,-0.160,
1293.00488,6.598,2371.57690,-1.160,
1293.09644,6.598,2371.66821,-0.160,
1293.18799,6.598,2371.75977,-1.160,
1293.27954,6.598,2371.85132,-1.160,
1293.37097,5.598,2371.94287,-1.160,
1293.46252,5.598,2372.03442,-0.160,
1293.55408,5.598,2372.12598,-0.160,
1293.64563,6.598,2372.21753,-1.160,
1293.73706,6.598,2372.30884,-0.160,
1293.82861,6.598,2372.40039,-0.160,
1293.92017,7.598,2372.49194,-1.160,
1294.01172,6.598,2372.58350,-1.160,
1294.10315,7.598,2372.67505,-0.160,
1294.19470,7.598,2372.76660,-0.160,
1294.28625,7.598,2372.85815,-1.160,
1294.37769,7.598,2372.94971,-1.160,
1294.46924,7.598,2373.04102,-0.160,
1294.56079,7.598,2373.13257,-0.160,
1294.65234,7.598,2373.22412,-0.160,
1294.74377,7.598,2373.31567,-0.160,
1294.83533,7.598,2373.40723,-0.160,
1294.92688,7.598,2373.49878,-1.160,
1295.01843,7.598,2373.59033,-0.160,
1295.10986,7.598,2373.68164,-0.160,
1295.20142,7.598,2373.77319,-1.160,
1295.29297,7.598,2373.86475,-0.160,
1295.38452,8.598,2373.95630,-0.160,
1295.47595,7.598,2374.04785,-0.160,
1295.56750,7.598,2374.13940,-0.160,
1295.65906,7.598,2374.23096,-0.160,
1295.75061,7.598,2374.32251,-0.160,
1295.84204,7.598,2374.41382,-0.160,
1295.93359,6.598,2374.50537,-0.160,
1296.02515,7.598,2374.59692,0.840,
1296.11658,7.598,2374.68848,-1.160,
1296.20813,7.598,2374.78003,-0.160,
1296.29968,7.598,2374.87158,-0.160,
1296.39124,6.598,2374.96313,-0.160,
1296.48267,6.598,2375.05469,-0.160,
1296.57422,7.598,2375.14600,-0.160,
1296.66577,7.598,2375.23755,-0.160,
1296.75732,7.598,2375.32910,-0.160,
1296.84875,7.598,2375.42065,-0.160,
1296.94031,7.598,2375.51221,-0.160,
1297.03186,7.598,2375.60376,-0.160,
1297.12341,7.598,2375.69531,-0.160,
1297.21484,7.598,2375.78662,-0.160,
1297.30640,7.598,2375.87817,-1.160,
1297.39795,7.598,2375.96973,-0.160,
1297.48950,7.598,2376.06128,-0.160,
1297.58093,7.598,2376.15283,-0.160,
1297.67249,7.598,2376.24438,-1.160,
1297.76404,7.598,2376.33594,-1.160,
1297.85559,7.598,2376.42749,-0.160,
1297.94702,7.598,2376.51880,-1.160,
1298.03857,6.598,2376.61035,-1.160,
1298.13013,7.598,2376.70190,-0.160,
1298.22156,7.598,2376.79346,-0.160,
1298.31311,7.598,2376.88501,-0.160,
1298.40466,7.598,2376.97656,-1.160,
1298.49622,7.598,2377.06812,-0.160,
1298.58765,7.598,2377.15967,-1.160,
1298.67920,7.598,2377.25098,-0.160,
1298.77075,7.598,2377.34253,-0.160,
1298.86230,7.598,2377.43408,-1.160,
1298.95374,7.598,2377.52563,-0.160,
1299.04529,7.598,2377.61719,-1.160,
1299.13684,7.598,2377.70874,-1.160,
1299.22839,7.598,2377.80029,-1.160,
1299.31982,7.598,2377.89160,-1.160,
1299.41138,7.598,2377.98315,-1.160,
1299.50293,7.598,2378.07471,-1.160,
1299.59448,7.598,2378.16626,-1.160,
1299.68591,7.598,2378.25781,-1.160,
1299.77747,8.598,2378.34937,-1.160,
1299.86902,8.598,2378.44092,-1.160,
1299.96045,7.598,2378.53247,-1.160,
1300.05200,7.598,2378.62378,-1.160,
1300.14355,7.598,2378.71533,-2.160,
1300.23511,8.598,2378.80688,-0.160,
1300.32654,8.598,2378.89844,-1.160,
1300.41809,7.598,2378.98999,-0.160,
1300.50964,8.598,2379.08154,-1.160,
1300.60120,8.598,2379.17310,-1.160,
1300.69263,7.598,2379.26440,-1.160,
1300.78418,7.598,2379.35596,-1.160,
1300.87573,7.598,2379.44751,-0.160,
1300.96729,7.598,2379.53906,-0.160,
1301.05872,7.598,2379.63062,-1.160,
1301.15027,7.598,2379.72217,-1.160,
1301.24182,8.598,2379.81372,-0.160,
1301.33337,7.598,2379.90527,-1.160,
1301.42480,7.598,2379.99658,-1.160,
1301.51636,7.598,2380.08813,-0.160,
1301.60791,7.598,2380.17969,-0.160,
1301.69934,7.598,2380.27124,-1.160,
1301.79089,7.598,2380.36279,-0.160,
1301.88245,8.598,2380.45435,-0.160,
1301.97400,8.598,2380.54590,-1.160,
1302.06543,7.598,2380.63745,-0.160,
1302.15698,8.598,2380.72876,-0.160,
1302.24854,7.598,2380.82031,-0.160,
1302.34009,7.598,2380.91187,-0.160,
1302.43152,8.598,2381.00342,-1.160,
1302.52307,8.598,2381.09497,-0.160,
1302.61462,7.598,2381.18652,-1.160,
1302.70618,8.598,2381.27808,-1.160,
1302.79761,8.598,2381.36938,-0.160,
1302.88916,7.598,2381.46094,-1.160,
1302.98071,7.598,2381.55249,-1.160,
1303.07227,8.598,2381.64404,-1.160,
1303.16370,8.598,2381.73560,-1.160,
1303.25525,7.598,2381.82715,-1.160,
1303.34680,8.598,2381.91870,0.840,
1303.43835,8.598,2382.01025,-0.160,
1303.52979,7.598,2382.10156,-1.160,
1303.62134,8.598,2382.19312,-0.160,
1303.71289,8.598,2382.28467,-0.160,
1303.80432,7.598,2382.37622,-1.160,
1303.89587,7.598,2382.46777,-0.160,
1303.98743,8.598,2382.55933,-0.160,
1304.07898,8.598,2382.65088,-0.160,
1304.17041,8.598,2382.74243,-0.160,
1304.26196,8.598,2382.83374,-1.160,
1304.35352,7.598,2382.92529,-1.160,
1304.44507,7.598,2383.01685,-1.160,
1304.53650,8.598,2383.10840,-1.160,
1304.62805,8.598,2383.19995,-0.160,
1304.71960,8.598,2383.29150,-1.160,
1304.81116,8.598,2383.38306,-0.160,
1304.90259,8.598,2383.47437,-0.160,
1304.99414,8.598,2383.56592,-0.160,
1305.08569,7.598,2383.65747,-0.160,
1305.17725,8.598,2383.74902,-0.160,
1305.26868,7.598,2383.84058,-0.160,
1305.36023,7.598,2383.93213,-0.160,
1305.45178,7.598,2384.02368,-0.160,
1305.54321,7.598,2384.11523,-0.160,
1305.63477,7.598,2384.20654,-0.160,
1305.72632,7.598,2384.29810,-1.160,
1305.81787,7.598,2384.38965,-0.160,
1305.90930,8.598,2384.48120,-0.160,
1306.00085,7.598,2384.57275,-1.160,
1306.09241,8.598,2384.66431,-0.160,
1306.18396,8.598,2384.75586,-1.160,
1306.27539,8.598,2384.84717,-0.160,
1306.36694,8.598,2384.93872,-0.160,
1306.45850,8.598,2385.03027,-0.160,
1306.55005,7.598,2385.12183,-0.160,
1306.64148,7.598,2385.21338,-0.160,
1306.73303,8.598,2385.30493,-0.160,
1306.82458,8.598,2385.39648,-0.160,
1306.91614,7.598,2385.48804,-1.160,
1307.00757,7.598,2385.57935,-0.160,
1307.09912,8.598,2385.67090,-0.160,
1307.19067,7.598,2385.76245,-1.160,
1307.28223,7.598,2385.85400,-1.160,
1307.37366,8.598,2385.94556,-0.160,
1307.46521,8.598,2386.03711,-1.160,
1307.55676,8.598,2386.12866,-1.160,
1307.64819,8.598,2386.22021,-0.160,
1307.73975,8.598,2386.31152,-0.160,
1307.83130,7.598,2386.40308,-0.160,
1307.92285,7.598,2386.49463,-0.160,
1308.01428,8.598,2386.58618,-0.160,
1308.10583,8.598,2386.67773,-0.160,
1308.19739,7.598,2386.76929,-1.160,
1308.28894,8.598,2386.86084,-0.160,
1308.38037,7.598,2386.95215,-0.160,
1308.47192,7.598,2387.04370,-1.160,
1308.56348,8.598,2387.13525,-1.160,
1308.65503,8.598,2387.22681,-0.160,
1308.74646,8.598,2387.31836,-1.160,
1308.83801,8.598,2387.40991,-1.160,
1308.92957,8.598,2387.50146,-0.160,
1309.02112,8.598,2387.59302,-0.160,
1309.11255,8.598,2387.68433,-1.160,
1309.20410,8.598,2387.77588,-0.160,
1309.29565,8.598,2387.86743,-0.160,
1309.38708,7.598,2387.95898,-0.160,
1309.47864,8.598,2388.05054,-1.160,
1309.57019,8.598,2388.14209,-0.160,
1309.66174,8.598,2388.23364,-0.160,
1309.75317,7.598,2388.32520,-0.160,
1309.84473,8.598,2388.41650,-0.160,
1309.93628,7.598,2388.50806,-0.160,
1310.02783,8.598,2388.59961,-1.160,
1310.11926,8.598,2388.69116,-0.160,
1310.21082,7.598,2388.78271,-1.160,
1310.30237,7.598,2388.87427,-0.160,
1310.39392,8.598,2388.96582,-1.160,
1310.48535,8.598,2389.05713,-0.160,
1310.57690,7.598,2389.14868,-1.160,
1310.66846,7.598,2389.24023,-0.160,
1310.76001,8.598,2389.33179,-0.160,
1310.85144,7.598,2389.42334,-0.160,
1310.94299,8.598,2389.51489,-0.160,
1311.03455,7.598,2389.60645,-0.160,
1311.12598,8.598,2389.69800,-0.160,
1311.21753,7.598,2389.78931,-0.160,
1311.30908,8.598,2389.88086,-0.160,
1311.40063,8.598,2389.97241,-0.160,
1311.49207,7.598,2390.06396,-0.160,
1311.58362,7.598,2390.15552,-0.160,
1311.67517,8.598,2390.24707,-0.160,
1311.76672,8.598,2390.33862,-0.160,
1311.85815,8.598,2390.43018,-1.160,
1311.94971,9.598,2390.52148,-0.160,
1312.04126,9.598,2390.61304,-1.160,
1312.13281,8.598,2390.70459,-0.160,
1312.22424,8.598,2390.79614,-0.160,
1312.31580,8.598,2390.88770,-0.160,
1312.40735,8.598,2390.97925,-1.160,
1312.49890,8.598,2391.07080,-0.160,
1312.59033,9.598,2391.16211,-0.160,
1312.68188,8.598,2391.25366,-1.160,
1312.77344,8.598,2391.34521,-1.160,
1312.86499,8.598,2391.43677,-0.160,
1312.95642,8.598,2391.52832,-0.160,
1313.04797,7.598,2391.61987,-0.160,
1313.13953,8.598,2391.71143,-0.160,
1313.23096,8.598,2391.80298,-0.160,
1313.32251,7.598,2391.89429,-0.160,
1313.41406,7.598,2391.98584,-0.160,
1313.50562,8.598,2392.07739,-0.160,
1313.59705,7.598,2392.16895,-0.160,
1313.68860,8.598,2392.26050,-1.160,
1313.78015,8.598,2392.35205,-0.160,
1313.87170,8.598,2392.44360,-0.160,
1313.96313,8.598,2392.53491,-0.160,
1314.05469,8.598,2392.62646,-0.160,
1314.14624,8.598,2392.71802,-0.160,
1314.23779,8.598,2392.80957,-0.160,
1314.32922,7.598,2392.90112,-0.160,
1314.42078,9.598,2392.99268,-0.160,
1314.51233,8.598,2393.08423,-1.160,
1314.60388,8.598,2393.17578,-1.160,
1314.69531,8.598,2393.26709,-1.160,
1314.78687,8.598,2393.35864,-1.160,
1314.87842,8.598,2393.45020,-2.160,
1314.96985,8.598,2393.54175,-1.160,
1315.06140,8.598,2393.63330,-0.160,
1315.15295,8.598,2393.72485,-1.160,
1315.24451,8.598,2393.81641,-1.160,
1315.33594,8.598,2393.90796,-1.160,
1315.42749,8.598,2393.99927,-1.160,
1315.51904,8.598,2394.09082,-1.160,
1315.61060,8.598,2394.18237,-1.160,
1315.70203,8.598,2394.27393,-1.160,
1315.79358,8.598,2394.36548,-1.160,
1315.88513,8.598,2394.45703,-1.160,
1315.97668,8.598,2394.54858,-1.160,
1316.06812,8.598,2394.63989,-1.160,
1316.15967,8.598,2394.73145,-1.160,
1316.25122,8.598,2394.82300,-0.160,
1316.34277,8.598,2394.91455,-0.160,
1316.43420,8.598,2395.00610,-0.160,
1316.52576,8.598,2395.09766,-0.160,
1316.61731,8.598,2395.18921,-1.160,
1316.70886,7.598,2395.28076,-0.160,
1316.80029,8.598,2395.37207,-0.160,
1316.89185,8.598,2395.46362,-0.160,
1316.98340,8.598,2395.55518,0.840,
1317.07483,8.598,2395.64673,0.840,
1317.16638,8.598,2395.73828,0.840,
1317.25793,8.598,2395.82983,1.840,
1317.34949,8.598,2395.92139,1.840,
1317.44092,8.598,2396.01294,0.840,
1317.53247,8.598,2396.10425,0.840,
1317.62402,8.598,2396.19580,0.840,
1317.71558,8.598,2396.28735,0.840,
1317.80701,8.598,2396.37891,0.840,
1317.89856,8.598,2396.47046,-0.160,
1317.99011,8.598,2396.56201,0.840,
1318.08167,8.598,2396.65356,0.840,
1318.17310,8.598,2396.74487,0.840,
1318.26465,7.598,2396.83643,-0.160,
1318.35620,8.598,2396.92798,-0.160,
1318.44775,8.598,2397.01953,-0.160,
1318.53918,7.598,2397.11108,-1.160,
1318.63074,7.598,2397.20264,-0.160,
1318.72229,8.598,2397.29419,-0.160,
1318.81372,8.598,2397.38574,-0.160,
1318.90527,8.598,2397.47705,-1.160,
1318.99683,8.598,2397.56860,-1.160,
1319.08838,8.598,2397.66016,-0.160,
1319.17981,8.598,2397.75171,-0.160,
1319.27136,8.598,2397.84326,-0.160,
1319.36292,8.598,2397.93481,-1.160,
1319.45447,8.598,2398.02637,-0.160,
1319.54590,8.598,2398.11768,-0.160,
1319.63745,8.598,2398.20923,-1.160,
1319.72900,8.598,2398.30078,-1.160,
1319.82056,8.598,2398.39233,-0.160,
1319.91199,8.598,2398.48389,-0.160,
1320.00354,8.598,2398.57544,-1.160,
1320.09509,8.598,2398.66699,-1.160,
1320.18665,8.598,2398.75854,-0.160,
1320.27808,9.598,2398.84985,-0.160,
1320.36963,8.598,2398.94141,-0.160,
1320.46118,8.598,2399.03296,-1.160,
1320.55261,8.598,2399.12451,-1.160,
1320.64417,8.598,2399.21606,-0.160,
1320.73572,8.598,2399.30762,-1.160,
1320.82727,9.598,2399.39917,-0.160,
1320.91870,8.598,2399.49072,-0.160,
1321.01025,8.598,2399.58203,-0.160,
1321.10181,8.598,2399.67358,-0.160,
1321.19336,8.598,2399.76514,-0.160,
1321.28479,8.598,2399.85669,-0.160,
1321.37634,8.598,2399.94824,-1.160,
1321.46790,8.598,2400.03979,-0.160,
1321.55945,8.598,2400.13135,-0.160,
1321.65088,8.598,2400.22266,-1.160,
1321.74243,9.598,2400.31421,-1.160,
1321.83398,8.598,2400.40576,-0.160,
1321.92554,9.598,2400.49731,-1.160,
1322.01697,9.598,2400.58887,-0.160,
1322.10852,8.598,2400.68042,-0.160,
1322.20007,9.598,2400.77197,-0.160,
1322.29163,8.598,2400.86353,-1.160,
1322.38306,9.598,2400.95483,-0.160,
1322.47461,9.598,2401.04639,-0.160,
1322.56616,8.598,2401.13794,-0.160,
1322.65759,9.598,2401.22949,-0.160,
1322.74915,8.598,2401.32104,-0.160,
1322.84070,8.598,2401.41260,-1.160,
1322.93225,8.598,2401.50415,-0.160,
1323.02368,9.598,2401.59570,-0.160,
1323.11523,9.598,2401.68701,-0.160,
1323.20679,8.598,2401.77856,-1.160,
1323.29834,9.598,2401.87012,-0.160,
1323.38977,8.598,2401.96167,-0.160,
1323.48132,8.598,2402.05322,-0.160,
1323.57288,9.598,2402.14478,-0.160,
1323.66443,8.598,2402.23633,-0.160,
1323.75586,8.598,2402.32764,-1.160,
1323.84741,8.598,2402.41919,-0.160,
1323.93896,8.598,2402.51074,-0.160,
1324.03052,8.598,2402.60229,-1.160,
1324.12195,8.598,2402.69385,-0.160,
1324.21350,8.598,2402.78540,-0.160,
1324.30505,8.598,2402.87695,-1.160,
1324.39648,7.598,2402.96851,-0.160,
1324.48804,8.598,2403.05981,-1.160,
1324.57959,8.598,2403.15137,-0.160,
1324.67114,9.598,2403.24292,-1.160,
1324.76257,8.598,2403.33447,-0.160,
1324.85413,8.598,2403.42603,-0.160,
1324.94568,9.598,2403.51758,-1.160,
1325.03723,8.598,2403.60913,-1.160,
1325.12866,9.598,2403.70044,-0.160,
1325.22021,9.598,2403.79199,-0.160,
1325.31177,8.598,2403.88354,-0.160,
1325.40332,8.598,2403.97510,-0.160,
1325.49475,8.598,2404.06665,-0.160,
1325.58630,8.598,2404.15820,-0.160,
1325.67786,8.598,2404.24976,-1.160,
1325.76941,8.598,2404.34131,-1.160,
1325.86084,8.598,2404.43262,-0.160,
1325.95239,8.598,2404.52417,-1.160,
1326.04395,8.598,2404.61572,-0.160,
1326.13550,9.598,2404.70728,-1.160,
1326.22693,8.598,2404.79883,-1.160,
1326.31848,8.598,2404.89038,-0.160,
1326.41003,8.598,2404.98193,-0.160,
1326.50146,9.598,2405.07349,-1.160,
1326.59302,8.598,2405.16479,-1.160,
1326.68457,9.598,2405.25635,-1.160,
1326.77612,9.598,2405.34790,-0.160,
1326.86755,8.598,2405.43945,-0.160,
1326.95911,8.598,2405.53101,-0.160,
1327.05066,8.598,2405.62256,-0.160,
1327.14221,8.598,2405.71411,-1.160,
1327.23364,8.598,2405.80542,-0.160,
1327.32520,9.598,2405.89697,-0.160,
1327.41675,9.598,2405.98853,-1.160,
1327.50830,9.598,2406.08008,-1.160,
1327.59973,10.598,2406.17163,-0.160,
1327.69128,9.598,2406.26318,-1.160,
1327.78284,8.598,2406.35474,-1.160,
1327.87439,9.598,2406.44629,-0.160,
1327.96582,9.598,2406.53760,-0.160,
1328.05737,8.598,2406.62915,-0.160,
1328.14893,8.598,2406.72070,-0.160,
1328.24036,8.598,2406.81226,-0.160,
1328.33191,8.598,2406.90381,-1.160,
1328.42346,7.598,2406.99536,-0.160,
1328.51501,8.598,2407.08691,-1.160,
1328.60645,8.598,2407.17847,-0.160,
1328.69800,7.598,2407.26978,-1.160,
1328.78955,8.598,2407.36133,-1.160,
1328.88110,8.598,2407.45288,-1.160,
1328.97253,8.598,2407.54443,-1.160,
1329.06409,9.598,2407.63599,-1.160,
1329.15564,8.598,2407.72754,-1.160,
1329.24719,8.598,2407.81909,-1.160,
1329.33862,9.598,2407.91040,-1.160,
1329.43018,8.598,2408.00195,-1.160,
1329.52173,8.598,2408.09351,-0.160,
1329.61328,8.598,2408.18506,-0.160,
1329.70471,9.598,2408.27661,-0.160,
1329.79626,9.598,2408.36816,-0.160,
1329.88782,9.598,2408.45972,-1.160,
1329.97925,9.598,2408.55127,-0.160,
1330.07080,9.598,2408.64258,-0.160,
1330.16235,9.598,2408.73413,-1.160,
1330.25391,9.598,2408.82568,-0.160,
1330.34534,8.598,2408.91724,-0.160,
1330.43689,9.598,2409.00879,-0.160,
1330.52844,9.598,2409.10034,-0.160,
1330.62000,8.598,2409.19189,-0.160,
1330.71143,9.598,2409.28345,-0.160,
1330.80298,8.598,2409.37476,-1.160,
1330.89453,8.598,2409.46631,-0.160,
1330.98608,8.598,2409.55786,-0.160,
1331.07751,8.598,2409.64941,-1.160,
1331.16907,8.598,2409.74097,-0.160,
1331.26062,8.598,2409.83252,-1.160,
1331.35217,8.598,2409.92407,-0.160,
1331.44360,8.598,2410.01538,-1.160,
1331.53516,8.598,2410.10693,-1.160,
1331.62671,8.598,2410.19849,-0.160,
1331.71826,8.598,2410.29004,-1.160,
1331.80969,8.598,2410.38159,-0.160,
1331.90125,8.598,2410.47314,-0.160,
1331.99280,9.598,2410.56470,-0.160,
1332.08423,8.598,2410.65625,-1.160,
1332.17578,8.598,2410.74756,-0.160,
1332.26733,9.598,2410.83911,-0.160,
1332.35889,8.598,2410.93066,-0.160,
1332.45032,9.598,2411.02222,-0.160,
1332.54187,9.598,2411.11377,-0.160,
1332.63342,9.598,2411.20532,0.840,
1332.72498,9.598,2411.29688,-0.160,
1332.81641,9.598,2411.38818,-0.160,
1332.90796,9.598,2411.47974,-0.160,
1332.99951,8.598,2411.57129,-0.160,
1333.09106,9.598,2411.66284,-0.160,
1333.18250,9.598,2411.75439,-0.160,
1333.27405,8.598,2411.84595,-1.160,
1333.36560,9.598,2411.93750,-0.160,
1333.45715,9.598,2412.02905,-0.160,
1333.54858,9.598,2412.12036,-0.160,
1333.64014,9.598,2412.21191,-0.160,
1333.73169,9.598,2412.30347,-0.160,
1333.82312,9.598,2412.39502,-0.160,
1333.91467,9.598,2412.48657,-1.160,
1334.00623,9.598,2412.57813,-0.160,
1334.09778,9.598,2412.66968,-0.160,
1334.18921,9.598,2412.76123,-1.160,
1334.28076,8.598,2412.85254,-0.160,
1334.37231,9.598,2412.94409,-1.160,
1334.46387,9.598,2413.03564,-0.160,
1334.55530,9.598,2413.12720,-0.160,
1334.64685,9.598,2413.21875,-1.160,
1334.73840,9.598,2413.31030,-1.160,
1334.82996,9.598,2413.40186,-1.160,
1334.92139,9.598,2413.49316,-2.160,
1335.01294,9.598,2413.58472,-2.160,
1335.10449,9.598,2413.67627,-2.160,
1335.19604,9.598,2413.76782,-2.160,
1335.28748,9.598,2413.85938,-1.160,
1335.37903,8.598,2413.95093,-2.160,
1335.47058,9.598,2414.04248,-1.160,
1335.56213,9.598,2414.13403,-1.160,
1335.65356,9.598,2414.22534,-1.160,
1335.74512,8.598,2414.31689,-2.160,
1335.83667,9.598,2414.40845,-1.160,
1335.92810,9.598,2414.50000,-1.160,
1336.01965,8.598,2414.59155,-1.160,
1336.11121,8.598,2414.68311,-1.160,
1336.20276,9.598,2414.77466,-1.160,
1336.29419,8.598,2414.86621,-1.160,
1336.38574,9.598,2414.95752,-1.160,
1336.47729,8.598,2415.04907,-1.160,
1336.56885,9.598,2415.14063,-1.160,
1336.66028,9.598,2415.23218,-1.160,
1336.75183,8.598,2415.32373,-1.160,
1336.84338,9.598,2415.41528,-1.160,
1336.93494,9.598,2415.50684,-1.160,
1337.02637,8.598,2415.59814,-0.160,
1337.11792,9.598,2415.68970,-0.160,
1337.20947,9.598,2415.78125,-1.160,
1337.30103,9.598,2415.87280,-1.160,
1337.39246,9.598,2415.96436,-1.160,
1337.48401,10.598,2416.05591,-0.160,
1337.57556,8.598,2416.14746,-1.160,
1337.66699,9.598,2416.23901,-1.160,
1337.75854,9.598,2416.33032,-0.160,
1337.85010,9.598,2416.42188,-1.160,
1337.94165,9.598,2416.51343,-0.160,
1338.03308,9.598,2416.60498,-1.160,
1338.12463,8.598,2416.69653,-1.160,
1338.21619,9.598,2416.78809,-1.160,
1338.30774,9.598,2416.87964,-0.160,
1338.39917,9.598,2416.97095,-1.160,
1338.49072,8.598,2417.06250,-0.160,
1338.58228,9.598,2417.15405,-1.160,
1338.67383,9.598,2417.24561,-0.160,
1338.76526,9.598,2417.33716,-1.160,
1338.85681,9.598,2417.42871,-0.160,
1338.94836,9.598,2417.52026,-1.160,
1339.03992,9.598,2417.61182,-1.160,
1339.13135,8.598,2417.70313,-1.160,
1339.22290,9.598,2417.79468,-1.160,
1339.31445,9.598,2417.88623,-0.160,
1339.40588,9.598,2417.97778,-1.160,
1339.49744,9.598,2418.06934,-0.160,
1339.58899,9.598,2418.16089,-1.160,
1339.68054,9.598,2418.25244,-1.160,
1339.77197,9.598,2418.34399,-1.160,
1339.86353,9.598,2418.43530,-1.160,
1339.95508,9.598,2418.52686,-0.160,
1340.04663,9.598,2418.61841,-1.160,
1340.13806,9.598,2418.70996,-0.160,
1340.22961,9.598,2418.80151,-1.160,
1340.32117,9.598,2418.89307,-0.160,
1340.41272,8.598,2418.98462,-1.160,
1340.50415,9.598,2419.07593,-1.160,
1340.59570,8.598,2419.16748,-1.160,
1340.68726,9.598,2419.25903,-1.160,
1340.77881,9.598,2419.35059,-1.160,
1340.87024,9.598,2419.44214,-1.160,
1340.96179,9.598,2419.53369,-0.160,
1341.05334,9.598,2419.62524,-1.160,
1341.14490,9.598,2419.71680,-1.160,
1341.23633,9.598,2419.80811,-1.160,
1341.32788,9.598,2419.89966,-1.160,
1341.41943,9.598,2419.99121,-0.160,
1341.51086,9.598,2420.08276,-1.160,
1341.60242,9.598,2420.17432,-1.160,
1341.69397,8.598,2420.26587,-0.160,
1341.78552,9.598,2420.35742,-1.160,
1341.87695,9.598,2420.44897,-0.160,
1341.96851,9.598,2420.54028,-0.160,
1342.06006,9.598,2420.63184,-1.160,
1342.15161,9.598,2420.72339,-1.160,
1342.24304,9.598,2420.81494,-1.160,
1342.33459,9.598,2420.90649,-0.160,
1342.42615,9.598,2420.99805,-1.160,
1342.51770,9.598,2421.08960,-1.160,
1342.60913,9.598,2421.18091,-0.160,
1342.70068,9.598,2421.27246,-1.160,
1342.79224,9.598,2421.36401,-1.160,
1342.88379,9.598,2421.45557,-0.160,
1342.97522,9.598,2421.54712,-1.160,
1343.06677,9.598,2421.63867,-1.160,
1343.15833,9.598,2421.73022,-1.160,
1343.24976,9.598,2421.82178,-0.160,
1343.34131,9.598,2421.91309,-1.160,
1343.43286,9.598,2422.00464,-1.160,
1343.52441,9.598,2422.09619,-0.160,
1343.61584,9.598,2422.18774,-0.160,
1343.70740,10.598,2422.27930,-1.160,
1343.79895,9.598,2422.37085,-1.160,
1343.89050,9.598,2422.46240,-1.160,
1343.98193,9.598,2422.55371,-0.160,
1344.07349,9.598,2422.64526,-1.160,
1344.16504,9.598,2422.73682,-0.160,
1344.25659,9.598,2422.82837,-0.160,
1344.34802,9.598,2422.91992,-0.160,
1344.43958,9.598,2423.01147,-0.160,
1344.53113,9.598,2423.10303,-0.160,
1344.62268,9.598,2423.19458,-0.160,
1344.71411,9.598,2423.28589,-0.160,
1344.80566,9.598,2423.37744,-0.160,
1344.89722,9.598,2423.46899,-0.160,
1344.98877,9.598,2423.56055,-0.160,
1345.08020,9.598,2423.65210,-0.160,
1345.17175,10.598,2423.74365,-0.160,
1345.26331,9.598,2423.83521,-1.160,
1345.35474,9.598,2423.92676,-0.160,
1345.44629,9.598,2424.01807,-1.160,
1345.53784,9.598,2424.10962,-1.160,
1345.62939,9.598,2424.20117,-1.160,
1345.72083,9.598,2424.29272,-0.160,
1345.81238,9.598,2424.38428,-0.160,
1345.90393,9.598,2424.47583,-1.160,
1345.99548,9.598,2424.56738,-0.160,
1346.08691,9.598,2424.65869,-0.160,
1346.17847,9.598,2424.75024,-0.160,
1346.27002,9.598,2424.84180,-0.160,
1346.36157,9.598,2424.93335,-0.160,
1346.45300,9.598,2425.02490,-0.160,
1346.54456,9.598,2425.11646,-1.160,
1346.63611,10.598,2425.20801,-0.160,
1346.72766,9.598,2425.29956,-1.160,
1346.81909,9.598,2425.39087,-0.160,
1346.91064,9.598,2425.48242,-0.160,
1347.00220,9.598,2425.57397,-0.160,
1347.09363,9.598,2425.66553,-1.160,
1347.18518,9.598,2425.75708,-0.160,
1347.27673,9.598,2425.84863,-0.160,
1347.36829,9.598,2425.94019,-1.160,
1347.45972,8.598,2426.03174,-0.160,
1347.55127,9.598,2426.12305,-0.160,
1347.64282,9.598,2426.21460,-0.160,
1347.73438,8.598,2426.30615,-1.160,
1347.82581,9.598,2426.39771,-0.160,
1347.91736,9.598,2426.48926,-0.160,
1348.00891,9.598,2426.58081,-0.160,
1348.10046,9.598,2426.67236,-0.160,
1348.19189,9.598,2426.76367,-0.160,
1348.28345,9.598,2426.85522,-1.160,
1348.37500,9.598,2426.94678,-1.160,
1348.46655,9.598,2427.03833,-0.160,
1348.55798,9.598,2427.12988,-1.160,
1348.64954,9.598,2427.22144,-1.160,
1348.74109,9.598,2427.31299,-0.160,
1348.83252,9.598,2427.40454,-1.160,
1348.92407,9.598,2427.49585,-1.160,
1349.01563,9.598,2427.58740,-1.160,
1349.10718,8.598,2427.67896,-0.160,
1349.19861,8.598,2427.77051,-1.160,
1349.29016,8.598,2427.86206,-1.160,
1349.38171,8.598,2427.95361,-0.160,
1349.47327,8.598,2428.04517,-1.160,
1349.56470,8.598,2428.13672,-1.160,
1349.65625,8.598,2428.22803,-0.160,
1349.74780,9.598,2428.31958,-0.160,
1349.83936,9.598,2428.41113,-0.160,
1349.93079,8.598,2428.50269,-0.160,
1350.02234,9.598,2428.59424,-0.160,
1350.11389,9.598,2428.68579,-0.160,
1350.20544,9.598,2428.77734,0.840,
1350.29688,9.598,2428.86865,-0.160,
1350.38843,9.598,2428.96021,-0.160,
1350.47998,9.598,2429.05176,-0.160,
1350.57153,9.598,2429.14331,-0.160,
1350.66296,9.598,2429.23486,-0.160,
1350.75452,10.598,2429.32642,-0.160,
1350.84607,9.598,2429.41797,-0.160,
1350.93750,10.598,2429.50952,-0.160,
1351.02905,10.598,2429.60083,-0.160,
1351.12061,9.598,2429.69238,-1.160,
1351.21216,9.598,2429.78394,-0.160,
1351.30359,9.598,2429.87549,-0.160,
1351.39514,9.598,2429.96704,-1.160,
1351.48669,9.598,2430.05859,-1.160,
1351.57825,9.598,2430.15015,-0.160,
1351.66968,9.598,2430.24146,-1.160,
1351.76123,9.598,2430.33301,-0.160,
1351.85278,9.598,2430.42456,-0.160,
1351.94434,9.598,2430.51611,-0.160,
1352.03577,9.598,2430.60767,-0.160,
1352.12732,9.598,2430.69922,-1.160,
1352.21887,9.598,2430.79077,-1.160,
1352.31042,9.598,2430.88232,-2.160,
1352.40186,9.598,2430.97363,-1.160,
1352.49341,10.598,2431.06519,-1.160,
1352.58496,9.598,2431.15674,-1.160,
1352.67639,9.598,2431.24829,-1.160,
1352.76794,10.598,2431.33984,-0.160,
1352.85950,9.598,2431.43140,-0.160,
1352.95105,9.598,2431.52295,-1.160,
1353.04248,9.598,2431.61450,-0.160,
1353.13403,9.598,2431.70581,-0.160,
1353.22559,9.598,2431.79736,-0.160,
1353.31714,9.598,2431.88892,-0.160,
1353.40857,10.598,2431.98047,-0.160,
1353.50012,9.598,2432.07202,-0.160,
1353.59167,9.598,2432.16357,-0.160,
1353.68323,9.598,2432.25513,-0.160,
1353.77466,9.598,2432.34644,-0.160,
1353.86621,9.598,2432.43799,-1.160,
1353.95776,10.598,2432.52954,-0.160,
1354.04932,9.598,2432.62109,-1.160,
1354.14075,9.598,2432.71265,-1.160,
1354.23230,9.598,2432.80420,-1.160,
1354.32385,9.598,2432.89575,-0.160,
1354.41541,9.598,2432.98730,-1.160,
1354.50684,9.598,2433.07861,-0.160,
1354.59839,9.598,2433.17017,-0.160,
1354.68994,9.598,2433.26172,-1.160,
1354.78137,9.598,2433.35327,-1.160,
1354.87292,9.598,2433.44482,-0.160,
1354.96448,9.598,2433.53638,-1.160,
1355.05603,8.598,2433.62793,-0.160,
1355.14746,9.598,2433.71948,-0.160,
1355.23901,10.598,2433.81079,-0.160,
1355.33057,9.598,2433.90234,-0.160,
1355.42212,10.598,2433.99390,-0.160,
1355.51355,9.598,2434.08545,-0.160,
1355.60510,9.598,2434.17700,-0.160,
1355.69666,9.598,2434.26855,-1.160,
1355.78821,9.598,2434.36011,-0.160,
1355.87964,9.598,2434.45142,-0.160,
1355.97119,9.598,2434.54297,-0.160,
1356.06274,9.598,2434.63452,-0.160,
1356.15430,9.598,2434.72607,-0.160,
1356.24573,9.598,2434.81763,-0.160,
1356.33728,9.598,2434.90918,-0.160,
1356.42883,9.598,2435.00073,-0.160,
1356.52026,9.598,2435.09229,-0.160,
1356.61182,9.598,2435.18359,-1.160,
1356.70337,9.598,2435.27515,-0.160,
1356.79492,10.598,2435.36670,-0.160,
1356.88635,9.598,2435.45825,-0.160,
1356.97791,9.598,2435.54980,-0.160,
1357.06946,10.598,2435.64136,-0.160,
1357.16101,9.598,2435.73291,-1.160,
1357.25244,9.598,2435.82422,-1.160,
1357.34399,9.598,2435.91577,-0.160,
1357.43555,9.598,2436.00732,-0.160,
1357.52710,9.598,2436.09888,-0.160,
1357.61853,9.598,2436.19043,-0.160,
1357.71008,10.598,2436.28198,-0.160,
1357.80164,9.598,2436.37354,-0.160,
1357.89319,9.598,2436.46509,-0.160,
1357.98462,9.598,2436.55640,-0.160,
1358.07617,9.598,2436.64795,-0.160,
1358.16772,9.598,2436.73950,-0.160,
1358.25916,9.598,2436.83105,-0.160,
1358.35071,9.598,2436.92261,-0.160,
1358.44226,9.598,2437.01416,-0.160,
1358.53381,9.598,2437.10571,-0.160,
1358.62524,9.598,2437.19727,-0.160,
1358.71680,9.598,2437.28857,-0.160,
1358.80835,9.598,2437.38013,-0.160,
1358.89990,9.598,2437.47168,-0.160,
1358.99133,9.598,2437.56323,0.840,
1359.08289,9.598,2437.65479,-0.160,
1359.17444,9.598,2437.74634,0.840,
1359.26599,9.598,2437.83789,-0.160,
1359.35742,9.598,2437.92920,-0.160,
1359.44897,9.598,2438.02075,-0.160,
1359.54053,9.598,2438.11230,-0.160,
1359.63208,9.598,2438.20386,-0.160,
1359.72351,9.598,2438.29541,-0.160,
1359.81506,10.598,2438.38696,-0.160,
1359.90662,9.598,2438.47852,-0.160,
1359.99817,9.598,2438.57007,-0.160,
1360.08960,9.598,2438.66138,-0.160,
1360.18115,9.598,2438.75293,-0.160,
1360.27271,9.598,2438.84448,-1.160,
1360.36414,9.598,2438.93604,-0.160,
1360.45569,9.598,2439.02759,-0.160,
1360.54724,9.598,2439.11914,-0.160,
1360.63879,9.598,2439.21069,-0.160,
1360.73022,9.598,2439.30225,-0.160,
1360.82178,9.598,2439.39355,-0.160,
1360.91333,9.598,2439.48511,-0.160,
1361.00488,9.598,2439.57666,-0.160,
1361.09631,9.598,2439.66821,-0.160,
1361.18787,9.598,2439.75977,-0.160,
1361.27942,9.598,2439.85132,-0.160,
1361.37097,9.598,2439.94287,-0.160,
1361.46240,9.598,2440.03418,-0.160,
1361.55396,9.598,2440.12573,-0.160,
1361.64551,9.598,2440.21729,-0.160,
1361.73706,9.598,2440.30884,-0.160,
1361.82849,9.598,2440.40039,-0.160,
1361.92004,9.598,2440.49194,0.840,
1362.01160,9.598,2440.58350,-0.160,
1362.10303,9.598,2440.67505,-0.160,
1362.19458,9.598,2440.76636,-0.160,
1362.28613,9.598,2440.85791,-0.160,
1362.37769,9.598,2440.94946,-0.160,
1362.46912,9.598,2441.04102,-0.160,
1362.56067,9.598,2441.13257,0.840,
1362.65222,9.598,2441.22412,-0.160,
1362.74377,9.598,2441.31567,-0.160,
1362.83521,9.598,2441.40698,-0.160,
1362.92676,9.598,2441.49854,0.840,
1363.01831,9.598,2441.59009,-0.160,
1363.10986,9.598,2441.68164,-0.160,
1363.20129,9.598,2441.77319,-0.160,
1363.29285,9.598,2441.86475,-0.160,
1363.38440,9.598,2441.95630,0.840,
1363.47595,9.598,2442.04785,-0.160,
1363.56738,9.598,2442.13916,-0.160,
1363.65894,9.598,2442.23071,-0.160,
1363.75049,9.598,2442.32227,0.840,
1363.84204,9.598,2442.41382,-0.160,
1363.93347,9.598,2442.50537,0.840,
1364.02502,9.598,2442.59692,0.840,
1364.11658,8.598,2442.68848,0.840,
1364.20801,9.598,2442.78003,0.840,
1364.29956,9.598,2442.87134,-0.160,
1364.39111,9.598,2442.96289,-0.160,
1364.48267,9.598,2443.05444,0.840,
1364.57410,9.598,2443.14600,0.840,
1364.66565,9.598,2443.23755,-0.160,
1364.75720,9.598,2443.32910,-0.160,
1364.84875,9.598,2443.42065,0.840,
1364.94019,9.598,2443.51196,-0.160,
1365.03174,9.598,2443.60352,-0.160,
1365.12329,9.598,2443.69507,-0.160,
1365.21484,9.598,2443.78662,-0.160,
1365.30627,9.598,2443.87817,-0.160,
1365.39783,9.598,2443.96973,0.840,
1365.48938,9.598,2444.06128,-0.160,
1365.58093,9.598,2444.15283,0.840,
1365.67236,10.598,2444.24414,0.840,
1365.76392,9.598,2444.33569,-0.160,
1365.85547,9.598,2444.42725,0.840,
1365.94690,9.598,2444.51880,-0.160,
1366.03845,9.598,2444.61035,-0.160,
1366.13000,9.598,2444.70190,-0.160,
1366.22156,9.598,2444.79346,0.840,
1366.31299,9.598,2444.88501,0.840,
1366.40454,9.598,2444.97632,-0.160,
1366.49609,9.598,2445.06787,0.840,
1366.58765,9.598,2445.15942,-0.160,
1366.67908,9.598,2445.25098,0.840,
1366.77063,9.598,2445.34253,-0.160,
1366.86218,10.598,2445.43408,0.840,
1366.95374,9.598,2445.52563,-0.160,
1367.04517,9.598,2445.61694,-0.160,
1367.13672,10.598,2445.70850,-0.160,
1367.22827,9.598,2445.80005,0.840,
1367.31982,9.598,2445.89160,-0.160,
1367.41125,9.598,2445.98315,0.840,
1367.50281,8.598,2446.07471,0.840,
1367.59436,9.598,2446.16626,0.840,
1367.68579,9.598,2446.25781,0.840,
1367.77734,9.598,2446.34912,1.840,
1367.86890,9.598,2446.44067,0.840,
1367.96045,8.598,2446.53223,0.840,
1368.05188,9.598,2446.62378,1.840,
1368.14343,8.598,2446.71533,0.840,
1368.23499,9.598,2446.80688,0.840,
1368.32654,8.598,2446.89844,0.840,
1368.41797,8.598,2446.98999,0.840,
1368.50952,9.598,2447.08130,0.840,
1368.60107,9.598,2447.17285,0.840,
1368.69263,9.598,2447.26440,0.840,
1368.78406,9.598,2447.35596,0.840,
1368.87561,9.598,2447.44751,0.840,
1368.96716,9.598,2447.53906,0.840,
1369.05872,9.598,2447.63062,0.840,
1369.15015,9.598,2447.72192,0.840,
1369.24170,9.598,2447.81348,0.840,
1369.33325,10.598,2447.90503,0.840,
1369.42480,9.598,2447.99658,0.840,
1369.51624,9.598,2448.08813,0.840,
1369.60779,9.598,2448.17969,0.840,
1369.69934,9.598,2448.27124,0.840,
1369.79077,9.598,2448.36279,0.840,
1369.88232,9.598,2448.45410,0.840,
1369.97388,9.598,2448.54565,-0.160,
1370.06543,9.598,2448.63721,-0.160,
1370.15686,9.598,2448.72876,0.840,
1370.24841,9.598,2448.82031,0.840,
1370.33997,9.598,2448.91187,0.840,
1370.43152,9.598,2449.00342,0.840,
1370.52295,8.598,2449.09473,0.840,
1370.61450,9.598,2449.18628,0.840,
1370.70605,9.598,2449.27783,0.840,
1370.79761,9.598,2449.36938,0.840,
1370.88904,9.598,2449.46094,-0.160,
1370.98059,9.598,2449.55249,-0.160,
1371.07214,9.598,2449.64404,-0.160,
1371.16370,9.598,2449.73560,0.840,
1371.25513,9.598,2449.82690,-0.160,
1371.34668,9.598,2449.91846,-0.160,
1371.43823,9.598,2450.01001,-0.160,
1371.52966,9.598,2450.10156,0.840,
1371.62122,9.598,2450.19312,-0.160,
1371.71277,9.598,2450.28467,0.840,
1371.80432,9.598,2450.37622,0.840,
1371.89575,9.598,2450.46777,-0.160,
1371.98730,9.598,2450.55908,0.840,
1372.07886,9.598,2450.65063,0.840,
1372.17041,9.598,2450.74219,0.840,
1372.26184,9.598,2450.83374,-0.160,
1372.35339,8.598,2450.92529,0.840,
1372.44495,9.598,2451.01685,0.840,
1372.53650,8.598,2451.10840,0.840,
1372.62793,8.598,2451.19971,0.840,
1372.71948,9.598,2451.29126,0.840,
1372.81104,8.598,2451.38281,0.840,
1372.90259,9.598,2451.47437,0.840,
1372.99402,9.598,2451.56592,0.840,
1373.08557,9.598,2451.65747,0.840,
1373.17712,8.598,2451.74902,-0.160,
1373.26855,9.598,2451.84058,0.840,
1373.36011,8.598,2451.93188,0.840,
1373.45166,8.598,2452.02344,0.840,
1373.54321,9.598,2452.11499,0.840,
1373.63464,9.598,2452.20654,1.840,
1373.72620,9.598,2452.29810,0.840,
1373.81775,9.598,2452.38965,0.840,
1373.90930,8.598,2452.48120,0.840,
1374.00073,8.598,2452.57275,0.840,
1374.09229,8.598,2452.66406,0.840,
1374.18384,8.598,2452.75562,1.840,
1374.27539,9.598,2452.84717,0.840,
1374.36682,8.598,2452.93872,0.840,
1374.45837,9.598,2453.03027,0.840,
1374.54993,8.598,2453.12183,0.840,
1374.64148,9.598,2453.21338,0.840,
1374.73291,9.598,2453.30469,0.840,
1374.82446,9.598,2453.39624,0.840,
1374.91602,9.598,2453.48779,0.840,
1375.00757,8.598,2453.57935,0.840,
1375.09900,8.598,2453.67090,1.840,
1375.19055,9.598,2453.76245,0.840,
1375.28210,9.598,2453.85400,0.840,
1375.37354,9.598,2453.94556,0.840,
1375.46509,8.598,2454.03687,0.840,
1375.55664,9.598,2454.12842,0.840,
1375.64819,8.598,2454.21997,0.840,
1375.73962,9.598,2454.31152,0.840,
1375.83118,9.598,2454.40308,0.840,
1375.92273,9.598,2454.49463,0.840,
1376.01428,9.598,2454.58618,0.840,
1376.10571,9.598,2454.67749,0.840,
1376.19727,9.598,2454.76904,0.840,
1376.28882,9.598,2454.86060,0.840,
1376.38037,9.598,2454.95215,-0.160,
1376.47180,9.598,2455.04370,1.840,
1376.56335,9.598,2455.13525,1.840,
1376.65491,9.598,2455.22681,0.840,
1376.74646,9.598,2455.31836,1.840,
1376.83789,9.598,2455.40967,0.840,
1376.92944,9.598,2455.50122,0.840,
1377.02100,9.598,2455.59277,0.840,
1377.11243,8.598,2455.68433,0.840,
1377.20398,9.598,2455.77588,0.840,
1377.29553,9.598,2455.86743,0.840,
1377.38708,9.598,2455.95898,0.840,
1377.47852,9.598,2456.05054,0.840,
1377.57007,9.598,2456.14185,0.840,
1377.66162,9.598,2456.23340,0.840,
1377.75317,8.598,2456.32495,-0.160,
1377.84460,8.598,2456.41650,0.840,
1377.93616,8.598,2456.50806,0.840,
1378.02771,8.598,2456.59961,1.840,
1378.11926,8.598,2456.69116,0.840,
1378.21069,8.598,2456.78247,0.840,
1378.30225,8.598,2456.87402,0.840,
1378.39380,8.598,2456.96558,0.840,
1378.48535,8.598,2457.05713,0.840,
1378.57678,8.598,2457.14868,0.840,
1378.66833,8.598,2457.24023,0.840,
1378.75989,8.598,2457.33179,1.840,
1378.85144,9.598,2457.42334,0.840,
1378.94287,8.598,2457.51465,0.840,
1379.03442,8.598,2457.60620,0.840,
1379.12598,8.598,2457.69775,0.840,
1379.21741,9.598,2457.78931,0.840,
1379.30896,8.598,2457.88086,0.840,
1379.40051,8.598,2457.97241,0.840,
1379.49207,9.598,2458.06396,0.840,
1379.58350,8.598,2458.15552,-0.160,
1379.67505,8.598,2458.24683,0.840,
1379.76660,8.598,2458.33838,0.840,
1379.85815,8.598,2458.42993,0.840,
1379.94958,8.598,2458.52148,0.840,
1380.04114,9.598,2458.61304,-0.160,
1380.13269,9.598,2458.70459,0.840,
1380.22424,8.598,2458.79614,-0.160,
1380.31567,10.598,2458.88745,0.840,
1380.40723,9.598,2458.97900,0.840,
1380.49878,9.598,2459.07056,0.840,
1380.59033,9.598,2459.16211,-0.160,
1380.68176,9.598,2459.25366,0.840,
1380.77332,9.598,2459.34521,1.840,
1380.86487,8.598,2459.43677,0.840,
1380.95630,9.598,2459.52832,1.840,
1381.04785,9.598,2459.61963,0.840,
1381.13940,9.598,2459.71118,0.840,
1381.23096,9.598,2459.80273,1.840,
1381.32239,9.598,2459.89429,0.840,
1381.41394,8.598,2459.98584,0.840,
1381.50549,8.598,2460.07739,0.840,
1381.59705,8.598,2460.16895,0.840,
1381.68848,8.598,2460.26025,0.840,
1381.78003,9.598,2460.35181,0.840,
1381.87158,8.598,2460.44336,0.840,
1381.96313,9.598,2460.53491,0.840,
1382.05457,9.598,2460.62646,0.840,
1382.14612,8.598,2460.71802,0.840,
1382.23767,9.598,2460.80957,0.840,
1382.32922,8.598,2460.90112,0.840,
1382.42065,9.598,2460.99243,0.840,
1382.51221,9.598,2461.08398,0.840,
1382.60376,9.598,2461.17554,0.840,
1382.69519,9.598,2461.26709,0.840,
1382.78674,8.598,2461.35864,0.840,
1382.87830,8.598,2461.45020,0.840,
1382.96985,8.598,2461.54175,0.840,
1383.06128,8.598,2461.63330,0.840,
1383.15283,8.598,2461.72461,0.840,
1383.24438,9.598,2461.81616,0.840,
1383.33594,9.598,2461.90771,0.840,
1383.42737,9.598,2461.99927,0.840,
1383.51892,8.598,2462.09082,0.840,
1383.61047,8.598,2462.18237,0.840,
1383.70203,9.598,2462.27393,0.840,
1383.79346,9.598,2462.36523,0.840,
1383.88501,9.598,2462.45679,1.840,
1383.97656,8.598,2462.54834,-0.160,
1384.06812,8.598,2462.63989,0.840,
1384.15955,8.598,2462.73145,0.840,
1384.25110,8.598,2462.82300,0.840,
1384.34265,8.598,2462.91455,0.840,
1384.43420,8.598,2463.00610,-0.160,
1384.52563,8.598,2463.09741,0.840,
1384.61719,7.598,2463.18896,0.840,
1384.70874,9.598,2463.28052,0.840,
1384.80017,8.598,2463.37207,-0.160,
1384.89172,8.598,2463.46362,0.840,
1384.98328,8.598,2463.55518,0.840,
1385.07483,8.598,2463.64673,0.840,
1385.16626,8.598,2463.73828,-0.160,
1385.25781,8.598,2463.82959,0.840,
1385.34937,8.598,2463.92114,0.840,
1385.44092,8.598,2464.01270,-0.160,
1385.53235,8.598,2464.10425,-0.160,
1385.62390,8.598,2464.19580,-0.160,
1385.71545,8.598,2464.28735,-0.160,
1385.80701,8.598,2464.37891,0.840,
1385.89844,8.598,2464.47021,0.840,
1385.98999,8.598,2464.56177,-0.160,
1386.08154,9.598,2464.65332,0.840,
1386.17310,9.598,2464.74487,0.840,
1386.26453,8.598,2464.83643,0.840,
1386.35608,8.598,2464.92798,0.840,
1386.44763,9.598,2465.01953,0.840,
1386.53906,9.598,2465.11108,0.840,
1386.63062,9.598,2465.20239,0.840,
1386.72217,9.598,2465.29395,0.840,
1386.81372,9.598,2465.38550,1.840,
1386.90515,9.598,2465.47705,0.840,
1386.99670,9.598,2465.56860,0.840,
1387.08826,9.598,2465.66016,0.840,
1387.17981,9.598,2465.75171,0.840,
1387.27124,9.598,2465.84326,0.840,
1387.36279,9.598,2465.93457,0.840,
1387.45435,8.598,2466.02612,0.840,
1387.54590,8.598,2466.11768,0.840,
1387.63733,9.598,2466.20923,0.840,
1387.72888,8.598,2466.30078,0.840,
1387.82043,8.598,2466.39233,-0.160,
1387.91199,8.598,2466.48389,0.840,
1388.00342,8.598,2466.57520,0.840,
1388.09497,8.598,2466.66675,0.840,
1388.18652,8.598,2466.75830,0.840,
1388.27808,8.598,2466.84985,0.840,
1388.36951,9.598,2466.94141,0.840,
1388.46106,8.598,2467.03296,0.840,
1388.55261,8.598,2467.12451,0.840,
1388.64404,8.598,2467.21606,1.840,
1388.73560,8.598,2467.30737,1.840,
1388.82715,8.598,2467.39893,0.840,
1388.91870,8.598,2467.49048,0.840,
1389.01013,8.598,2467.58203,0.840,
1389.10168,9.598,2467.67358,0.840,
1389.19324,8.598,2467.76514,0.840,
1389.28479,9.598,2467.85669,0.840,
1389.37622,9.598,2467.94800,0.840,
1389.46777,9.598,2468.03955,0.840,
1389.55933,9.598,2468.13110,0.840,
1389.65088,9.598,2468.22266,0.840,
1389.74231,8.598,2468.31421,1.840,
1389.83386,8.598,2468.40576,0.840,
1389.92542,9.598,2468.49731,0.840,
1390.01697,8.598,2468.58887,0.840,
1390.10840,8.598,2468.68018,0.840,
1390.19995,9.598,2468.77173,0.840,
1390.29150,9.598,2468.86328,0.840,
1390.38293,9.598,2468.95483,0.840,
1390.47449,8.598,2469.04639,0.840,
1390.56604,9.598,2469.13794,0.840,
1390.65759,8.598,2469.22949,0.840,
1390.74902,9.598,2469.32104,0.840,
1390.84058,9.598,2469.41235,0.840,
1390.93213,9.598,2469.50391,0.840,
1391.02368,9.598,2469.59546,0.840,
1391.11511,9.598,2469.68701,0.840,
1391.20667,9.598,2469.77856,1.840,
1391.29822,9.598,2469.87012,0.840,
1391.38977,9.598,2469.96167,0.840,
1391.48120,9.598,2470.05298,0.840,
1391.57275,8.598,2470.14453,1.840,
1391.66431,8.598,2470.23608,0.840,
1391.75586,8.598,2470.32764,0.840,
1391.84729,9.598,2470.41919,0.840,
1391.93884,9.598,2470.51074,0.840,
1392.03040,10.598,2470.60229,0.840,
1392.12183,9.598,2470.69385,0.840,
1392.21338,9.598,2470.78516,0.840,
1392.30493,9.598,2470.87671,0.840,
1392.39648,9.598,2470.96826,0.840,
1392.48792,8.598,2471.05981,0.840,
1392.57947,9.598,2471.15137,0.840,
1392.67102,9.598,2471.24292,0.840,
1392.76257,9.598,2471.33447,0.840,
1392.85400,9.598,2471.42603,0.840,
1392.94556,9.598,2471.51733,1.840,
1393.03711,8.598,2471.60889,0.840,
1393.12866,9.598,2471.70044,0.840,
1393.22009,9.598,2471.79199,0.840,
1393.31165,8.598,2471.88354,0.840,
1393.40320,8.598,2471.97510,0.840,
1393.49475,9.598,2472.06665,0.840,
1393.58618,9.598,2472.15796,0.840,
1393.67773,9.598,2472.24951,0.840,
1393.76929,9.598,2472.34106,0.840,
1393.86084,9.598,2472.43262,0.840,
1393.95227,9.598,2472.52417,0.840,
1394.04382,8.598,2472.61572,-0.160,
1394.13538,9.598,2472.70728,0.840,
1394.22681,9.598,2472.79883,0.840,
1394.31836,9.598,2472.89014,0.840,
1394.40991,9.598,2472.98169,0.840,
1394.50146,9.598,2473.07324,0.840,
1394.59290,9.598,2473.16479,0.840,
1394.68445,9.598,2473.25635,0.840,
1394.77600,9.598,2473.34790,0.840,
1394.86755,9.598,2473.43945,0.840,
1394.95898,9.598,2473.53076,0.840,
1395.05054,9.598,2473.62231,0.840,
1395.14209,9.598,2473.71387,0.840,
1395.23364,8.598,2473.80542,0.840,
1395.32507,9.598,2473.89697,-0.160,
1395.41663,9.598,2473.98853,0.840,
1395.50818,9.598,2474.08008,0.840,
1395.59973,9.598,2474.17163,0.840,
1395.69116,9.598,2474.26294,0.840,
1395.78271,9.598,2474.35449,0.840,
1395.87427,9.598,2474.44604,0.840,
1395.96570,9.598,2474.53760,0.840,
1396.05725,9.598,2474.62915,0.840,
1396.14880,9.598,2474.72070,0.840,
1396.24036,9.598,2474.81226,0.840,
1396.33179,9.598,2474.90381,0.840,
1396.42334,9.598,2474.99512,0.840,
1396.51489,9.598,2475.08667,0.840,
1396.60645,9.598,2475.17822,0.840,
1396.69788,9.598,2475.26978,0.840,
1396.78943,8.598,2475.36133,0.840,
1396.88098,9.598,2475.45288,0.840,
1396.97253,9.598,2475.54443,0.840,
1397.06396,9.598,2475.63574,1.840,
1397.15552,9.598,2475.72729,1.840,
1397.24707,9.598,2475.81885,0.840,
1397.33862,9.598,2475.91040,0.840,
1397.43005,9.598,2476.00195,0.840,
1397.52161,9.598,2476.09351,0.840,
1397.61316,9.598,2476.18506,0.840,
1397.70471,9.598,2476.27661,0.840,
1397.79614,9.598,2476.36792,0.840,
1397.88770,10.598,2476.45947,0.840,
1397.97925,9.598,2476.55103,0.840,
1398.07068,9.598,2476.64258,0.840,
1398.16223,9.598,2476.73413,0.840,
1398.25378,9.598,2476.82568,0.840,
1398.34534,9.598,2476.91724,0.840,
1398.43677,9.598,2477.00879,0.840,
1398.52832,9.598,2477.10010,1.840,
1398.61987,10.598,2477.19165,0.840,
1398.71143,9.598,2477.28320,0.840,
1398.80286,9.598,2477.37476,0.840,
1398.89441,10.598,2477.46631,0.840,
1398.98596,9.598,2477.55786,0.840,
1399.07751,9.598,2477.64941,0.840,
1399.16895,9.598,2477.74072,0.840,
1399.26050,9.598,2477.83228,1.840,
1399.35205,10.598,2477.92383,0.840,
1399.44360,10.598,2478.01538,1.840,
1399.53503,9.598,2478.10693,0.840,
1399.62659,9.598,2478.19849,0.840,
1399.71814,9.598,2478.29004,0.840,
1399.80957,9.598,2478.38159,1.840,
1399.90112,9.598,2478.47290,0.840,
1399.99268,9.598,2478.56445,1.840,
1400.08423,9.598,2478.65601,0.840,
1400.17566,9.598,2478.74756,0.840,
1400.26721,9.598,2478.83911,0.840,
1400.35876,9.598,2478.93066,1.840,
1400.45032,9.598,2479.02222,0.840,
1400.54175,9.598,2479.11353,0.840,
1400.63330,9.598,2479.20508,1.840,
1400.72485,9.598,2479.29663,0.840,
1400.81641,9.598,2479.38818,0.840,
1400.90784,9.598,2479.47974,0.840,
1400.99939,9.598,2479.57129,0.840,
1401.09094,9.598,2479.66284,0.840,
1401.18250,9.598,2479.75439,1.840,
1401.27393,9.598,2479.84570,0.840,
1401.36548,9.598,2479.93726,0.840,
1401.45703,10.598,2480.02881,1.840,
1401.54846,10.598,2480.12036,0.840,
1401.64001,9.598,2480.21191,0.840,
1401.73157,9.598,2480.30347,1.840,
1401.82312,9.598,2480.39502,1.840,
1401.91455,9.598,2480.48657,1.840,
1402.00610,9.598,2480.57788,0.840,
1402.09766,9.598,2480.66943,0.840,
1402.18921,10.598,2480.76099,0.840,
1402.28064,11.598,2480.85254,0.840,
1402.37219,9.598,2480.94409,0.840,
1402.46375,10.598,2481.03564,0.840,
1402.55530,9.598,2481.12720,0.840,
1402.64673,9.598,2481.21851,0.840,
1402.73828,10.598,2481.31006,0.840,
1402.82983,10.598,2481.40161,1.840,
1402.92139,10.598,2481.49316,2.840,
1403.01282,9.598,2481.58472,1.840,
1403.10437,9.598,2481.67627,1.840,
1403.19592,9.598,2481.76782,1.840,
1403.28748,9.598,2481.85938,1.840,
1403.37891,9.598,2481.95068,1.840,
1403.47046,9.598,2482.04224,1.840,
1403.56201,9.598,2482.13379,1.840,
1403.65344,9.598,2482.22534,0.840,
1403.74500,10.598,2482.31689,0.840,
1403.83655,9.598,2482.40845,0.840,
1403.92810,9.598,2482.50000,0.840,
1404.01953,9.598,2482.59155,0.840,
1404.11108,9.598,2482.68286,0.840,
1404.20264,9.598,2482.77441,0.840,
1404.29419,10.598,2482.86597,1.840,
1404.38562,10.598,2482.95752,1.840,
1404.47717,10.598,2483.04907,1.840,
1404.56873,10.598,2483.14063,0.840,
1404.66028,10.598,2483.23218,0.840,
1404.75171,10.598,2483.32349,0.840,
1404.84326,10.598,2483.41504,0.840,
1404.93481,11.598,2483.50659,1.840,
1405.02637,11.598,2483.59814,1.840,
1405.11780,11.598,2483.68970,0.840,
1405.20935,12.598,2483.78125,0.840,
1405.30090,11.598,2483.87280,0.840,
1405.39233,11.598,2483.96436,0.840,
1405.48389,10.598,2484.05566,1.840,
1405.57544,10.598,2484.14722,0.840,
1405.66699,10.598,2484.23877,0.840,
1405.75842,10.598,2484.33032,0.840,
1405.84998,10.598,2484.42188,1.840,
1405.94153,9.598,2484.51343,0.840,
1406.03308,9.598,2484.60498,0.840,
1406.12451,9.598,2484.69629,1.840,
1406.21606,9.598,2484.78784,0.840,
1406.30762,9.598,2484.87939,0.840,
1406.39917,9.598,2484.97095,1.840,
1406.49060,10.598,2485.06250,1.840,
1406.58215,9.598,2485.15405,1.840,
1406.67371,10.598,2485.24561,1.840,
1406.76526,9.598,2485.33716,1.840,
1406.85669,9.598,2485.42847,1.840,
1406.94824,9.598,2485.52002,1.840,
1407.03979,9.598,2485.61157,1.840,
1407.13135,9.598,2485.70313,1.840,
1407.22278,9.598,2485.79468,1.840,
1407.31433,9.598,2485.88623,2.840,
1407.40588,10.598,2485.97778,0.840,
1407.49731,9.598,2486.06934,1.840,
1407.58887,9.598,2486.16064,1.840,
1407.68042,10.598,2486.25220,1.840,
1407.77197,9.598,2486.34375,1.840,
1407.86340,9.598,2486.43530,0.840,
1407.95496,9.598,2486.52686,1.840,
1408.04651,9.598,2486.61841,0.840,
1408.13806,10.598,2486.70996,0.840,
1408.22949,9.598,2486.80127,1.840,
1408.32104,10.598,2486.89282,1.840,
1408.41260,9.598,2486.98438,0.840,
1408.50415,9.598,2487.07593,0.840,
1408.59558,10.598,2487.16748,1.840,
1408.68713,9.598,2487.25903,1.840,
1408.77869,10.598,2487.35059,1.840,
1408.87024,9.598,2487.44214,1.840,
1408.96167,10.598,2487.53345,1.840,
1409.05322,9.598,2487.62500,0.840,
1409.14478,9.598,2487.71655,1.840,
1409.23621,10.598,2487.80811,1.840,
1409.32776,9.598,2487.89966,1.840,
1409.41931,10.598,2487.99121,1.840,
1409.51086,10.598,2488.08276,1.840,
1409.60229,10.598,2488.17432,1.840,
1409.69385,10.598,2488.26563,1.840,
1409.78540,9.598,2488.35718,1.840,
1409.87695,10.598,2488.44873,0.840,
1409.96838,9.598,2488.54028,0.840,
1410.05994,9.598,2488.63184,0.840,
1410.15149,10.598,2488.72339,0.840,
1410.24304,9.598,2488.81494,1.840,
1410.33447,10.598,2488.90625,0.840,
1410.42603,9.598,2488.99780,1.840,
1410.51758,9.598,2489.08936,1.840,
1410.60913,9.598,2489.18091,0.840,
1410.70056,9.598,2489.27246,0.840,
1410.79211,9.598,2489.36401,1.840,
1410.88367,10.598,2489.45557,0.840,
1410.97510,9.598,2489.54712,1.840,
1411.06665,10.598,2489.63843,1.840,
1411.15820,10.598,2489.72998,0.840,
1411.24976,10.598,2489.82153,0.840,
1411.34119,10.598,2489.91309,0.840,
1411.43274,10.598,2490.00464,1.840,
1411.52429,10.598,2490.09619,1.840,
1411.61584,10.598,2490.18774,1.840,
1411.70728,10.598,2490.27930,1.840,
1411.79883,9.598,2490.37061,1.840,
1411.89038,10.598,2490.46216,1.840,
1411.98193,10.598,2490.55371,0.840,
1412.07336,10.598,2490.64526,0.840,
1412.16492,9.598,2490.73682,0.840,
1412.25647,10.598,2490.82837,1.840,
1412.34802,10.598,2490.91992,1.840,
1412.43945,9.598,2491.01123,1.840,
1412.53101,10.598,2491.10278,1.840,
1412.62256,10.598,2491.19434,1.840,
1412.71411,10.598,2491.28589,0.840,
1412.80554,10.598,2491.37744,0.840,
1412.89709,9.598,2491.46899,1.840,
1412.98865,9.598,2491.56055,1.840,
1413.08008,10.598,2491.65210,1.840,
1413.17163,10.598,2491.74341,1.840,
1413.26318,10.598,2491.83496,0.840,
1413.35474,9.598,2491.92651,0.840,
1413.44617,9.598,2492.01807,1.840,
1413.53772,10.598,2492.10962,1.840,
1413.62927,9.598,2492.20117,0.840,
1413.72083,9.598,2492.29272,1.840,
1413.81226,9.598,2492.38403,1.840,
1413.90381,9.598,2492.47559,1.840,
1413.99536,10.598,2492.56714,1.840,
1414.08691,10.598,2492.65869,1.840,
1414.17834,10.598,2492.75024,1.840,
1414.26990,9.598,2492.84180,0.840,
1414.36145,10.598,2492.93335,0.840,
1414.45300,10.598,2493.02490,1.840,
1414.54443,9.598,2493.11621,1.840,
1414.63599,10.598,2493.20776,1.840,
1414.72754,10.598,2493.29932,1.840,
1414.81897,10.598,2493.39087,1.840,
1414.91052,9.598,2493.48242,1.840,
1415.00208,10.598,2493.57397,1.840,
1415.09363,10.598,2493.66553,0.840,
1415.18506,9.598,2493.75708,1.840,
1415.27661,9.598,2493.84839,1.840,
1415.36816,10.598,2493.93994,1.840,
1415.45972,10.598,2494.03149,1.840,
1415.55115,10.598,2494.12305,0.840,
1415.64270,10.598,2494.21460,1.840,
1415.73425,9.598,2494.30615,0.840,
1415.82581,9.598,2494.39771,1.840,
1415.91724,9.598,2494.48901,0.840,
1416.00879,10.598,2494.58057,1.840,
1416.10034,10.598,2494.67212,1.840,
1416.19189,10.598,2494.76367,1.840,
1416.28333,10.598,2494.85522,1.840,
1416.37488,10.598,2494.94678,1.840,
1416.46643,10.598,2495.03833,0.840,
1416.55798,10.598,2495.12988,1.840,
1416.64941,10.598,2495.22119,1.840,
1416.74097,10.598,2495.31274,0.840,
1416.83252,10.598,2495.40430,1.840,
1416.92395,10.598,2495.49585,1.840,
1417.01550,9.598,2495.58740,1.840,
1417.10706,10.598,2495.67896,1.840,
1417.19861,10.598,2495.77051,1.840,
1417.29004,10.598,2495.86206,0.840,
1417.38159,10.598,2495.95337,0.840,
1417.47314,10.598,2496.04492,1.840,
1417.56470,10.598,2496.13647,1.840,
1417.65613,10.598,2496.22803,0.840,
1417.74768,10.598,2496.31958,1.840,
1417.83923,10.598,2496.41113,1.840,
1417.93079,10.598,2496.50269,0.840,
1418.02222,10.598,2496.59399,1.840,
1418.11377,10.598,2496.68555,0.840,
1418.20532,9.598,2496.77710,0.840,
1418.29688,10.598,2496.86865,0.840,
1418.38831,10.598,2496.96021,0.840,
1418.47986,10.598,2497.05176,1.840,
1418.57141,9.598,2497.14331,0.840,
1418.66284,10.598,2497.23486,0.840,
1418.75439,10.598,2497.32617,1.840,
1418.84595,10.598,2497.41772,1.840,
1418.93750,10.598,2497.50928,0.840,
1419.02893,10.598,2497.60083,1.840,
1419.12048,10.598,2497.69238,0.840,
1419.21204,10.598,2497.78394,1.840,
1419.30359,10.598,2497.87549,1.840,
1419.39502,10.598,2497.96680,1.840,
1419.48657,10.598,2498.05835,0.840,
1419.57813,10.598,2498.14990,1.840,
1419.66968,10.598,2498.24146,1.840,
1419.76111,10.598,2498.33301,1.840,
1419.85266,10.598,2498.42456,0.840,
1419.94421,10.598,2498.51611,1.840,
1420.03577,10.598,2498.60767,1.840,
1420.12720,10.598,2498.69897,1.840,
1420.21875,10.598,2498.79053,1.840,
1420.31030,10.598,2498.88208,1.840,
1420.40173,10.598,2498.97363,1.840,
1420.49329,10.598,2499.06519,1.840,
1420.58484,10.598,2499.15674,1.840,
1420.67639,10.598,2499.24829,1.840,
1420.76782,10.598,2499.33984,1.840,
1420.85938,10.598,2499.43115,1.840,
1420.95093,10.598,2499.52271,1.840,
1421.04248,10.598,2499.61426,1.840,
1421.13391,10.598,2499.70581,2.840,
1421.22546,10.598,2499.79736,2.840,
1421.31702,10.598,2499.88892,1.840,
1421.40857,9.598,2499.98047,1.840,
1421.50000,10.598,2500.07178,1.840,
1421.59155,10.598,2500.16333,1.840,
1421.68311,10.598,2500.25488,1.840,
1421.77466,10.598,2500.34644,1.840,
1421.86609,10.598,2500.43799,1.840,
1421.95764,10.598,2500.52954,1.840,
1422.04919,10.598,2500.62109,1.840,
1422.14075,10.598,2500.71265,1.840,
1422.23218,10.598,2500.80396,1.840,
1422.32373,9.598,2500.89551,1.840,
1422.41528,10.598,2500.98706,1.840,
1422.50671,9.598,2501.07861,1.840,
1422.59827,9.598,2501.17017,1.840,
1422.68982,9.598,2501.26172,1.840,
1422.78137,9.598,2501.35327,1.840,
1422.87280,9.598,2501.44482,0.840,
1422.96436,9.598,2501.53613,1.840,
1423.05591,9.598,2501.62769,1.840,
1423.14746,9.598,2501.71924,0.840,
1423.23889,10.598,2501.81079,1.840,
1423.33044,10.598,2501.90234,1.840,
1423.42200,10.598,2501.99390,1.840,
1423.51355,10.598,2502.08545,1.840,
1423.60498,10.598,2502.17676,1.840,
1423.69653,10.598,2502.26831,2.840,
1423.78809,10.598,2502.35986,2.840,
1423.87964,11.598,2502.45142,2.840,
1423.97107,11.598,2502.54297,3.840,
1424.06262,10.598,2502.63452,3.840,
1424.15417,10.598,2502.72607,3.840,
1424.24561,11.598,2502.81763,3.840,
1424.33716,11.598,2502.90894,2.840,
1424.42871,10.598,2503.00049,2.840,
1424.52026,11.598,2503.09204,2.840,
1424.61169,10.598,2503.18359,2.840,
1424.70325,10.598,2503.27515,2.840,
1424.79480,10.598,2503.36670,2.840,
1424.88635,10.598,2503.45825,2.840,
1424.97778,11.598,2503.54956,1.840,
1425.06934,10.598,2503.64111,1.840,
1425.16089,10.598,2503.73267,2.840,
1425.25244,10.598,2503.82422,1.840,
1425.34387,10.598,2503.91577,1.840,
1425.43542,11.598,2504.00732,1.840,
1425.52698,10.598,2504.09888,1.840,
1425.61853,10.598,2504.19043,1.840,
1425.70996,10.598,2504.28174,1.840,
1425.80151,10.598,2504.37329,1.840,
1425.89307,10.598,2504.46484,1.840,
1425.98462,11.598,2504.55640,1.840,
1426.07605,10.598,2504.64795,1.840,
1426.16760,10.598,2504.73950,1.840,
1426.25916,10.598,2504.83105,1.840,
1426.35059,10.598,2504.92261,1.840,
1426.44214,11.598,2505.01392,1.840,
1426.53369,10.598,2505.10547,0.840,
1426.62524,10.598,2505.19702,1.840,
1426.71667,10.598,2505.28857,1.840,
1426.80823,10.598,2505.38013,1.840,
1426.89978,10.598,2505.47168,1.840,
1426.99133,10.598,2505.56323,1.840,
1427.08276,10.598,2505.65454,1.840,
1427.17432,11.598,2505.74609,1.840,
1427.26587,11.598,2505.83765,1.840,
1427.35742,10.598,2505.92920,1.840,
1427.44885,11.598,2506.02075,1.840,
1427.54041,11.598,2506.11230,1.840,
1427.63196,11.598,2506.20386,1.840,
1427.72351,10.598,2506.29541,1.840,
1427.81494,10.598,2506.38672,1.840,
1427.90649,11.598,2506.47827,2.840,
1427.99805,10.598,2506.56982,2.840,
1428.08948,10.598,2506.66138,1.840,
1428.18103,11.598,2506.75293,1.840,
1428.27258,11.598,2506.84448,1.840,
1428.36414,10.598,2506.93604,1.840,
1428.45557,11.598,2507.02759,1.840,
1428.54712,10.598,2507.11890,1.840,
1428.63867,11.598,2507.21045,1.840,
1428.73022,10.598,2507.30200,1.840,
1428.82166,11.598,2507.39355,1.840,
1428.91321,11.598,2507.48511,1.840,
1429.00476,10.598,2507.57666,1.840,
1429.09631,11.598,2507.66821,1.840,
1429.18774,11.598,2507.75952,1.840,
1429.27930,11.598,2507.85107,1.840,
1429.37085,11.598,2507.94263,1.840,
1429.46240,11.598,2508.03418,1.840,
1429.55383,10.598,2508.12573,1.840,
1429.64539,11.598,2508.21729,1.840,
1429.73694,10.598,2508.30884,1.840,
1429.82837,10.598,2508.40039,1.840,
1429.91992,11.598,2508.49170,0.840,
1430.01147,11.598,2508.58325,1.840,
1430.10303,11.598,2508.67480,1.840,
1430.19446,11.598,2508.76636,1.840,
1430.28601,10.598,2508.85791,1.840,
1430.37756,11.598,2508.94946,1.840,
1430.46912,11.598,2509.04102,1.840,
1430.56055,11.598,2509.13257,1.840,
1430.65210,11.598,2509.22388,1.840,
1430.74365,12.598,2509.31543,1.840,
1430.83521,11.598,2509.40698,1.840,
1430.92664,11.598,2509.49854,1.840,
1431.01819,11.598,2509.59009,1.840,
1431.10974,11.598,2509.68164,1.840,
1431.20129,11.598,2509.77319,1.840,
1431.29272,11.598,2509.86450,1.840,
1431.38428,10.598,2509.95605,1.840,
1431.47583,11.598,2510.04761,1.840,
1431.56738,12.598,2510.13916,1.840,
1431.65881,11.598,2510.23071,1.840,
1431.75037,11.598,2510.32227,1.840,
1431.84192,11.598,2510.41382,1.840,
1431.93335,11.598,2510.50537,1.840,
1432.02490,11.598,2510.59668,1.840,
1432.11646,10.598,2510.68823,1.840,
1432.20801,11.598,2510.77979,2.840,
1432.29944,11.598,2510.87134,1.840,
1432.39099,11.598,2510.96289,1.840,
1432.48254,10.598,2511.05444,1.840,
1432.57410,11.598,2511.14600,1.840,
1432.66553,10.598,2511.23730,1.840,
1432.75708,10.598,2511.32886,1.840,
1432.84863,11.598,2511.42041,1.840,
1432.94019,11.598,2511.51196,1.840,
1433.03162,11.598,2511.60352,1.840,
1433.12317,11.598,2511.69507,1.840,
1433.21472,11.598,2511.78662,1.840,
1433.30627,10.598,2511.87817,1.840,
1433.39771,11.598,2511.96948,1.840,
1433.48926,11.598,2512.06104,1.840,
1433.58081,11.598,2512.15259,1.840,
1433.67224,11.598,2512.24414,2.840,
1433.76379,10.598,2512.33569,1.840,
1433.85535,11.598,2512.42725,1.840,
1433.94690,10.598,2512.51880,1.840,
1434.03833,11.598,2512.61035,1.840,
1434.12988,11.598,2512.70166,1.840,
1434.22144,11.598,2512.79321,1.840,
1434.31299,10.598,2512.88477,1.840,
1434.40442,11.598,2512.97632,1.840,
1434.49597,11.598,2513.06787,1.840,
1434.58752,11.598,2513.15942,1.840,
1434.67908,11.598,2513.25098,1.840,
1434.77051,10.598,2513.34229,1.840,
1434.86206,11.598,2513.43384,1.840,
1434.95361,10.598,2513.52539,2.840,
1435.04517,11.598,2513.61694,1.840,
1435.13660,10.598,2513.70850,2.840,
1435.22815,11.598,2513.80005,1.840,
1435.31970,11.598,2513.89160,1.840,
1435.41125,10.598,2513.98315,1.840,
1435.50269,10.598,2514.07446,1.840,
1435.59424,11.598,2514.16602,1.840,
1435.68579,10.598,2514.25757,1.840,
1435.77722,10.598,2514.34912,1.840,
1435.86877,10.598,2514.44067,1.840,
1435.96033,11.598,2514.53223,1.840,
1436.05188,11.598,2514.62378,1.840,
1436.14331,10.598,2514.71533,1.840,
1436.23486,11.598,2514.80664,1.840,
1436.32642,10.598,2514.89819,1.840,
1436.41797,11.598,2514.98975,1.840,
1436.50940,10.598,2515.08130,1.840,
1436.60095,10.598,2515.17285,2.840,
1436.69250,10.598,2515.26440,1.840,
1436.78406,10.598,2515.35596,1.840,
1436.87549,11.598,2515.44727,1.840,
1436.96704,11.598,2515.53882,1.840,
1437.05859,10.598,2515.63037,1.840,
1437.15015,10.598,2515.72192,2.840,
1437.24158,11.598,2515.81348,1.840,
1437.33313,10.598,2515.90503,2.840,
1437.42468,11.598,2515.99658,1.840,
1437.51611,11.598,2516.08813,1.840,
1437.60767,11.598,2516.17944,1.840,
1437.69922,11.598,2516.27100,1.840,
1437.79077,11.598,2516.36255,1.840,
1437.88220,11.598,2516.45410,1.840,
1437.97375,11.598,2516.54565,1.840,
1438.06531,11.598,2516.63721,2.840,
1438.15686,11.598,2516.72876,1.840,
1438.24829,10.598,2516.82007,2.840,
1438.33984,11.598,2516.91162,2.840,
1438.43140,11.598,2517.00317,1.840,
1438.52295,11.598,2517.09473,1.840,
1438.61438,11.598,2517.18628,2.840,
1438.70593,11.598,2517.27783,1.840,
1438.79749,11.598,2517.36938,1.840,
1438.88904,12.598,2517.46094,1.840,
1438.98047,11.598,2517.55225,2.840,
1439.07202,11.598,2517.64380,1.840,
1439.16357,10.598,2517.73535,1.840,
1439.25500,11.598,2517.82690,1.840,
1439.34656,10.598,2517.91846,1.840,
1439.43811,11.598,2518.01001,1.840,
1439.52966,11.598,2518.10156,2.840,
1439.62109,11.598,2518.19312,2.840,
1439.71265,11.598,2518.28442,1.840,
1439.80420,10.598,2518.37598,2.840,
1439.89575,11.598,2518.46753,2.840,
1439.98718,11.598,2518.55908,1.840,
1440.07874,11.598,2518.65063,1.840,
1440.17029,11.598,2518.74219,2.840,
1440.26184,11.598,2518.83374,1.840,
1440.35327,11.598,2518.92505,1.840,
1440.44482,11.598,2519.01660,1.840,
1440.53638,11.598,2519.10815,1.840,
1440.62793,11.598,2519.19971,1.840,
1440.71936,12.598,2519.29126,1.840,
1440.81091,12.598,2519.38281,2.840,
1440.90247,12.598,2519.47437,1.840,
1440.99402,12.598,2519.56592,2.840,
1441.08545,13.598,2519.65723,2.840,
1441.17700,12.598,2519.74878,1.840,
1441.26855,12.598,2519.84033,1.840,
1441.35999,12.598,2519.93188,2.840,
1441.45154,12.598,2520.02344,1.840,
1441.54309,12.598,2520.11499,1.840,
1441.63464,12.598,2520.20654,1.840,
1441.72607,12.598,2520.29810,1.840,
1441.81763,12.598,2520.38940,1.840,
1441.90918,11.598,2520.48096,1.840,
1442.00073,11.598,2520.57251,1.840,
1442.09216,11.598,2520.66406,1.840,
1442.18372,11.598,2520.75562,0.840,
1442.27527,11.598,2520.84717,1.840,
1442.36682,11.598,2520.93872,1.840,
1442.45825,11.598,2521.03003,1.840,
1442.54980,11.598,2521.12158,1.840,
1442.64136,11.598,2521.21313,1.840,
1442.73291,11.598,2521.30469,1.840,
1442.82434,10.598,2521.39624,1.840,
1442.91589,11.598,2521.48779,1.840,
1443.00745,11.598,2521.57935,1.840,
1443.09888,10.598,2521.67090,1.840,
1443.19043,11.598,2521.76221,1.840,
1443.28198,11.598,2521.85376,1.840,
1443.37354,11.598,2521.94531,1.840,
1443.46497,11.598,2522.03687,1.840,
1443.55652,11.598,2522.12842,1.840,
1443.64807,11.598,2522.21997,1.840,
1443.73962,11.598,2522.31152,1.840,
1443.83105,11.598,2522.40283,1.840,
1443.92261,11.598,2522.49438,2.840,
1444.01416,11.598,2522.58594,1.840,
1444.10571,10.598,2522.67749,1.840,
1444.19714,11.598,2522.76904,2.840,
1444.28870,10.598,2522.86060,1.840,
1444.38025,11.598,2522.95215,2.840,
1444.47180,10.598,2523.04370,2.840,
1444.56323,11.598,2523.13501,2.840,
1444.65479,10.598,2523.22656,2.840,
1444.74634,11.598,2523.31812,1.840,
1444.83789,11.598,2523.40967,2.840,
1444.92932,11.598,2523.50122,1.840,
1445.02087,11.598,2523.59277,1.840,
1445.11243,11.598,2523.68433,2.840,
1445.20386,10.598,2523.77588,2.840,
1445.29541,10.598,2523.86719,2.840,
1445.38696,11.598,2523.95874,2.840,
1445.47852,11.598,2524.05029,2.840,
1445.56995,10.598,2524.14185,1.840,
1445.66150,11.598,2524.23340,2.840,
1445.75305,11.598,2524.32495,2.840,
1445.84460,11.598,2524.41650,1.840,
1445.93604,11.598,2524.50781,1.840,
1446.02759,11.598,2524.59937,1.840,
1446.11914,11.598,2524.69092,1.840,
1446.21069,12.598,2524.78247,1.840,
1446.30212,11.598,2524.87402,1.840,
1446.39368,11.598,2524.96558,1.840,
1446.48523,11.598,2525.05713,1.840,
1446.57678,11.598,2525.14868,1.840,
1446.66821,11.598,2525.23999,2.840,
1446.75977,11.598,2525.33154,1.840,
1446.85132,11.598,2525.42310,2.840,
1446.94275,11.598,2525.51465,2.840,
1447.03430,11.598,2525.60620,1.840,
1447.12585,11.598,2525.69775,1.840,
1447.21741,11.598,2525.78931,2.840,
1447.30884,11.598,2525.88086,2.840,
1447.40039,11.598,2525.97217,1.840,
1447.49194,11.598,2526.06372,1.840,
1447.58350,11.598,2526.15527,2.840,
1447.67493,12.598,2526.24683,1.840,
1447.76648,11.598,2526.33838,1.840,
1447.85803,11.598,2526.42993,1.840,
1447.94958,11.598,2526.52148,1.840,
1448.04102,11.598,2526.61279,1.840,
1448.13257,11.598,2526.70435,2.840,
1448.22412,11.598,2526.79590,2.840,
1448.31567,11.598,2526.88745,2.840,
1448.40710,11.598,2526.97900,2.840,
1448.49866,11.598,2527.07056,2.840,
1448.59021,11.598,2527.16211,1.840,
1448.68164,11.598,2527.25366,1.840,
1448.77319,11.598,2527.34497,1.840,
1448.86475,11.598,2527.43652,1.840,
1448.95630,11.598,2527.52808,1.840,
1449.04773,11.598,2527.61963,1.840,
1449.13928,12.598,2527.71118,1.840,
1449.23083,11.598,2527.80273,1.840,
1449.32239,11.598,2527.89429,1.840,
1449.41382,11.598,2527.98584,1.840,
1449.50537,11.598,2528.07715,1.840,
1449.59692,11.598,2528.16870,1.840,
1449.68848,11.598,2528.26025,1.840,
1449.77991,11.598,2528.35181,2.840,
1449.87146,11.598,2528.44336,1.840,
1449.96301,11.598,2528.53491,1.840,
1450.05457,11.598,2528.62646,2.840,
1450.14600,11.598,2528.71777,2.840,
1450.23755,11.598,2528.80933,2.840,
1450.32910,11.598,2528.90088,2.840,
1450.42065,11.598,2528.99243,2.840,
1450.51208,11.598,2529.08398,1.840,
1450.60364,12.598,2529.17554,2.840,
1450.69519,11.598,2529.26709,1.840,
1450.78662,11.598,2529.35864,1.840,
1450.87817,11.598,2529.44995,1.840,
1450.96973,11.598,2529.54150,1.840,
1451.06128,11.598,2529.63306,1.840,
1451.15271,11.598,2529.72461,1.840,
1451.24426,11.598,2529.81616,2.840,
1451.33582,11.598,2529.90771,1.840,
1451.42737,11.598,2529.99927,2.840,
1451.51880,12.598,2530.09058,2.840,
1451.61035,11.598,2530.18213,1.840,
1451.70190,11.598,2530.27368,2.840,
1451.79346,11.598,2530.36523,1.840,
1451.88489,11.598,2530.45679,1.840,
1451.97644,11.598,2530.54834,1.840,
1452.06799,12.598,2530.63989,1.840,
1452.15955,11.598,2530.73145,1.840,
1452.25098,11.598,2530.82275,1.840,
1452.34253,11.598,2530.91431,1.840,
1452.43408,11.598,2531.00586,2.840,
1452.52551,11.598,2531.09741,2.840,
1452.61707,11.598,2531.18896,1.840,
1452.70862,12.598,2531.28052,2.840,
1452.80017,12.598,2531.37207,1.840,
1452.89160,11.598,2531.46362,2.840,
1452.98315,11.598,2531.55493,1.840,
1453.07471,12.598,2531.64648,1.840,
1453.16626,11.598,2531.73804,1.840,
1453.25769,11.598,2531.82959,1.840,
1453.34924,12.598,2531.92114,2.840,
1453.44080,12.598,2532.01270,2.840,
1453.53235,12.598,2532.10425,1.840,
1453.62378,12.598,2532.19556,2.840,
1453.71533,12.598,2532.28711,1.840,
1453.80688,11.598,2532.37866,1.840,
1453.89844,11.598,2532.47021,1.840,
1453.98987,12.598,2532.56177,1.840,
1454.08142,12.598,2532.65332,1.840,
1454.17297,11.598,2532.74487,2.840,
1454.26453,11.598,2532.83643,1.840,
1454.35596,11.598,2532.92773,1.840,
1454.44751,11.598,2533.01929,2.840,
1454.53906,11.598,2533.11084,1.840,
1454.63049,11.598,2533.20239,1.840,
1454.72205,11.598,2533.29395,1.840,
1454.81360,11.598,2533.38550,1.840,
1454.90515,11.598,2533.47705,2.840,
1454.99658,12.598,2533.56860,1.840,
1455.08813,11.598,2533.65991,2.840,
1455.17969,12.598,2533.75146,2.840,
1455.27124,12.598,2533.84302,2.840,
1455.36267,11.598,2533.93457,2.840,
1455.45422,11.598,2534.02612,1.840,
1455.54578,12.598,2534.11768,2.840,
1455.63733,12.598,2534.20923,1.840,
1455.72876,12.598,2534.30054,1.840,
1455.82031,12.598,2534.39209,1.840,
1455.91187,12.598,2534.48364,1.840,
1456.00342,12.598,2534.57520,1.840,
1456.09485,12.598,2534.66675,1.840,
1456.18640,12.598,2534.75830,1.840,
1456.27795,12.598,2534.84985,1.840,
1456.36938,12.598,2534.94141,1.840,
1456.46094,12.598,2535.03271,1.840,
1456.55249,12.598,2535.12427,1.840,
1456.64404,12.598,2535.21582,1.840,
1456.73547,12.598,2535.30737,1.840,
1456.82703,11.598,2535.39893,2.840,
1456.91858,11.598,2535.49048,1.840,
1457.01013,11.598,2535.58203,2.840,
1457.10156,12.598,2535.67334,2.840,
1457.19312,11.598,2535.76489,2.840,
1457.28467,11.598,2535.85645,2.840,
1457.37622,11.598,2535.94800,2.840,
1457.46765,12.598,2536.03955,2.840,
1457.55920,11.598,2536.13110,2.840,
1457.65076,11.598,2536.22266,2.840,
1457.74231,11.598,2536.31421,2.840,
1457.83374,11.598,2536.40552,1.840,
1457.92529,12.598,2536.49707,2.840,
1458.01685,12.598,2536.58862,3.840,
1458.10828,11.598,2536.68018,2.840,
1458.19983,12.598,2536.77173,1.840,
1458.29138,12.598,2536.86328,2.840,
1458.38293,12.598,2536.95483,2.840,
1458.47437,12.598,2537.04639,2.840,
1458.56592,13.598,2537.13770,2.840,
1458.65747,13.598,2537.22925,2.840,
1458.74902,13.598,2537.32080,2.840,
1458.84045,13.598,2537.41235,2.840,
1458.93201,13.598,2537.50391,2.840,
1459.02356,13.598,2537.59546,1.840,
1459.11511,13.598,2537.68701,2.840,
1459.20654,13.598,2537.77832,2.840,
1459.29810,13.598,2537.86987,2.840,
1459.38965,13.598,2537.96143,1.840,
1459.48120,13.598,2538.05298,1.840,
1459.57263,13.598,2538.14453,1.840,
1459.66418,12.598,2538.23608,1.840,
1459.75574,12.598,2538.32764,1.840,
1459.84729,12.598,2538.41919,1.840,
1459.93872,12.598,2538.51050,1.840,
1460.03027,11.598,2538.60205,2.840,
1460.12183,12.598,2538.69360,1.840,
1460.21326,12.598,2538.78516,1.840,
1460.30481,11.598,2538.87671,1.840,
1460.39636,11.598,2538.96826,1.840,
1460.48792,11.598,2539.05981,2.840,
1460.57935,11.598,2539.15137,1.840,
1460.67090,11.598,2539.24268,1.840,
1460.76245,12.598,2539.33423,2.840,
1460.85400,11.598,2539.42578,1.840,
1460.94543,11.598,2539.51733,1.840,
1461.03699,11.598,2539.60889,2.840,
1461.12854,12.598,2539.70044,1.840,
1461.22009,11.598,2539.79199,2.840,
1461.31152,11.598,2539.88330,2.840,
1461.40308,11.598,2539.97485,2.840,
1461.49463,11.598,2540.06641,1.840,
1461.58618,11.598,2540.15796,1.840,
1461.67761,11.598,2540.24951,1.840,
1461.76917,11.598,2540.34106,1.840,
1461.86072,11.598,2540.43262,1.840,
1461.95215,11.598,2540.52417,1.840,
1462.04370,11.598,2540.61548,2.840,
1462.13525,11.598,2540.70703,1.840,
1462.22681,12.598,2540.79858,1.840,
1462.31824,12.598,2540.89014,1.840,
1462.40979,11.598,2540.98169,1.840,
1462.50134,11.598,2541.07324,1.840,
1462.59290,12.598,2541.16479,1.840,
1462.68433,11.598,2541.25610,1.840,
1462.77588,12.598,2541.34766,1.840,
1462.86743,12.598,2541.43921,1.840,
1462.95898,11.598,2541.53076,2.840,
1463.05042,11.598,2541.62231,1.840,
1463.14197,12.598,2541.71387,1.840,
1463.23352,11.598,2541.80542,1.840,
1463.32507,11.598,2541.89697,1.840,
1463.41650,11.598,2541.98828,1.840,
1463.50806,11.598,2542.07983,1.840,
1463.59961,11.598,2542.17139,1.840,
1463.69104,11.598,2542.26294,1.840,
1463.78259,12.598,2542.35449,1.840,
1463.87415,11.598,2542.44604,1.840,
1463.96570,12.598,2542.53760,1.840,
1464.05713,12.598,2542.62915,1.840,
1464.14868,12.598,2542.72046,1.840,
1464.24023,12.598,2542.81201,1.840,
1464.33179,12.598,2542.90356,1.840,
1464.42322,12.598,2542.99512,1.840,
1464.51477,12.598,2543.08667,2.840,
1464.60632,11.598,2543.17822,1.840,
1464.69788,12.598,2543.26978,1.840,
1464.78931,12.598,2543.36108,1.840,
1464.88086,11.598,2543.45264,1.840,
1464.97241,12.598,2543.54419,1.840,
1465.06396,11.598,2543.63574,1.840,
1465.15540,12.598,2543.72729,1.840,
1465.24695,12.598,2543.81885,1.840,
1465.33850,11.598,2543.91040,1.840,
1465.43005,12.598,2544.00195,1.840,
1465.52148,12.598,2544.09326,1.840,
1465.61304,12.598,2544.18481,1.840,
1465.70459,11.598,2544.27637,1.840,
1465.79602,11.598,2544.36792,1.840,
1465.88757,12.598,2544.45947,2.840,
1465.97913,12.598,2544.55103,2.840,
1466.07068,11.598,2544.64258,1.840,
1466.16211,11.598,2544.73413,2.840,
1466.25366,12.598,2544.82544,1.840,
1466.34521,12.598,2544.91699,1.840,
1466.43677,11.598,2545.00854,1.840,
1466.52820,12.598,2545.10010,1.840,
1466.61975,11.598,2545.19165,1.840,
1466.71130,12.598,2545.28320,1.840,
1466.80286,12.598,2545.37476,1.840,
1466.89429,12.598,2545.46606,2.840,
1466.98584,11.598,2545.55762,1.840,
1467.07739,12.598,2545.64917,1.840,
1467.16895,12.598,2545.74072,1.840,
1467.26038,12.598,2545.83228,1.840,
1467.35193,12.598,2545.92383,1.840,
1467.44348,12.598,2546.01538,1.840,
1467.53491,12.598,2546.10693,1.840,
1467.62646,12.598,2546.19824,1.840,
1467.71802,12.598,2546.28979,1.840,
1467.80957,12.598,2546.38135,1.840,
1467.90100,12.598,2546.47290,1.840,
1467.99255,12.598,2546.56445,1.840,
1468.08411,12.598,2546.65601,1.840,
1468.17566,12.598,2546.74756,1.840,
1468.26709,12.598,2546.83911,1.840,
1468.35864,11.598,2546.93042,1.840,
1468.45020,12.598,2547.02197,1.840,
1468.54175,12.598,2547.11353,1.840,
1468.63318,11.598,2547.20508,1.840,
1468.72473,12.598,2547.29663,1.840,
1468.81628,12.598,2547.38818,2.840,
1468.90784,12.598,2547.47974,1.840,
1468.99927,12.598,2547.57104,1.840,
1469.09082,12.598,2547.66260,1.840,
1469.18237,12.598,2547.75415,1.840,
1469.27393,12.598,2547.84570,1.840,
1469.36536,12.598,2547.93726,1.840,
1469.45691,11.598,2548.02881,1.840,
1469.54846,11.598,2548.12036,1.840,
1469.63989,12.598,2548.21191,1.840,
1469.73145,12.598,2548.30322,1.840,
1469.82300,12.598,2548.39478,1.840,
1469.91455,12.598,2548.48633,1.840,
1470.00598,12.598,2548.57788,1.840,
1470.09753,12.598,2548.66943,1.840,
1470.18909,12.598,2548.76099,1.840,
1470.28064,12.598,2548.85254,2.840,
1470.37207,11.598,2548.94385,1.840,
1470.46362,11.598,2549.03540,1.840,
1470.55518,12.598,2549.12695,1.840,
1470.64673,11.598,2549.21851,1.840,
1470.73816,11.598,2549.31006,1.840,
1470.82971,12.598,2549.40161,1.840,
1470.92126,12.598,2549.49316,1.840,
1471.01282,11.598,2549.58472,1.840,
1471.10425,12.598,2549.67603,1.840,
1471.19580,12.598,2549.76758,1.840,
1471.28735,12.598,2549.85913,0.840,
1471.37878,11.598,2549.95068,1.840,
1471.47034,12.598,2550.04224,1.840,
1471.56189,12.598,2550.13379,1.840,
1471.65344,11.598,2550.22534,1.840,
1471.74487,12.598,2550.31689,2.840,
1471.83643,12.598,2550.40820,1.840,
1471.92798,11.598,2550.49976,1.840,
1472.01953,11.598,2550.59131,1.840,
1472.11096,12.598,2550.68286,1.840,
1472.20251,11.598,2550.77441,0.840,
1472.29407,11.598,2550.86597,1.840,
1472.38562,12.598,2550.95752,1.840,
1472.47705,12.598,2551.04883,1.840,
1472.56860,13.598,2551.14038,1.840,
1472.66016,12.598,2551.23193,1.840,
1472.75171,12.598,2551.32349,1.840,
1472.84314,12.598,2551.41504,1.840,
1472.93469,12.598,2551.50659,1.840,
1473.02625,12.598,2551.59814,1.840,
1473.11768,12.598,2551.68970,1.840,
1473.20923,12.598,2551.78101,1.840,
1473.30078,12.598,2551.87256,1.840,
1473.39233,11.598,2551.96411,1.840,
1473.48376,12.598,2552.05566,1.840,
1473.57532,12.598,2552.14722,0.840,
1473.66687,12.598,2552.23877,1.840,
1473.75842,12.598,2552.33032,0.840,
1473.84985,13.598,2552.42188,1.840,
1473.94141,12.598,2552.51318,1.840,
1474.03296,13.598,2552.60474,1.840,
1474.12451,12.598,2552.69629,0.840,
1474.21594,12.598,2552.78784,1.840,
1474.30750,12.598,2552.87939,1.840,
1474.39905,12.598,2552.97095,1.840,
1474.49060,12.598,2553.06250,1.840,
1474.58203,12.598,2553.15381,1.840,
1474.67358,12.598,2553.24536,1.840,
1474.76514,12.598,2553.33691,1.840,
1474.85669,12.598,2553.42847,1.840,
1474.94812,12.598,2553.52002,1.840,
1475.03967,12.598,2553.61157,1.840,
1475.13123,11.598,2553.70313,1.840,
1475.22266,12.598,2553.79468,1.840,
1475.31421,12.598,2553.88599,1.840,
1475.40576,12.598,2553.97754,1.840,
1475.49731,13.598,2554.06909,1.840,
1475.58875,12.598,2554.16064,1.840,
1475.68030,11.598,2554.25220,0.840,
1475.77185,12.598,2554.34375,1.840,
1475.86340,12.598,2554.43530,1.840,
1475.95483,12.598,2554.52661,1.840,
1476.04639,13.598,2554.61816,1.840,
1476.13794,13.598,2554.70972,1.840,
1476.22949,13.598,2554.80127,0.840,
1476.32092,13.598,2554.89282,0.840,
1476.41248,13.598,2554.98438,1.840,
1476.50403,13.598,2555.07593,1.840,
1476.59558,13.598,2555.16748,1.840,
1476.68701,14.598,2555.25879,1.840,
1476.77856,13.598,2555.35034,1.840,
1476.87012,13.598,2555.44189,1.840,
1476.96155,14.598,2555.53345,1.840,
1477.05310,13.598,2555.62500,1.840,
1477.14465,13.598,2555.71655,0.840,
1477.23621,13.598,2555.80811,1.840,
1477.32764,13.598,2555.89966,1.840,
1477.41919,13.598,2555.99097,1.840,
1477.51074,12.598,2556.08252,1.840,
1477.60229,13.598,2556.17407,1.840,
1477.69373,12.598,2556.26563,1.840,
1477.78528,11.598,2556.35718,1.840,
1477.87683,12.598,2556.44873,1.840,
1477.96838,12.598,2556.54028,1.840,
1478.05981,11.598,2556.63159,0.840,
1478.15137,11.598,2556.72314,0.840,
1478.24292,12.598,2556.81470,1.840,
1478.33447,12.598,2556.90625,0.840,
1478.42590,12.598,2556.99780,0.840,
1478.51746,12.598,2557.08936,1.840,
1478.60901,11.598,2557.18091,0.840,
1478.70056,12.598,2557.27246,0.840,
1478.79199,12.598,2557.36377,0.840,
1478.88354,12.598,2557.45532,0.840,
1478.97510,12.598,2557.54688,-0.160,
1479.06653,12.598,2557.63843,1.840,
1479.15808,11.598,2557.72998,0.840,
1479.24963,12.598,2557.82153,0.840,
1479.34119,12.598,2557.91309,1.840,
1479.43262,12.598,2558.00464,1.840,
1479.52417,12.598,2558.09595,1.840,
1479.61572,11.598,2558.18750,1.840,
1479.70728,12.598,2558.27905,0.840,
1479.79871,12.598,2558.37061,1.840,
1479.89026,13.598,2558.46216,0.840,
1479.98181,12.598,2558.55371,1.840,
1480.07336,12.598,2558.64526,0.840,
1480.16479,12.598,2558.73657,1.840,
1480.25635,12.598,2558.82813,1.840,
1480.34790,12.598,2558.91968,1.840,
1480.43945,12.598,2559.01123,1.840,
1480.53088,12.598,2559.10278,1.840,
1480.62244,12.598,2559.19434,0.840,
1480.71399,12.598,2559.28589,0.840,
1480.80542,12.598,2559.37744,0.840,
1480.89697,12.598,2559.46875,0.840,
1480.98853,12.598,2559.56030,0.840,
1481.08008,11.598,2559.65186,1.840,
1481.17151,11.598,2559.74341,0.840,
1481.26306,11.598,2559.83496,0.840,
1481.35461,12.598,2559.92651,0.840,
1481.44617,11.598,2560.01807,0.840,
1481.53760,12.598,2560.10938,0.840,
1481.62915,11.598,2560.20093,0.840,
1481.72070,12.598,2560.29248,0.840,
1481.81226,11.598,2560.38403,0.840,
1481.90369,12.598,2560.47559,0.840,
1481.99524,11.598,2560.56714,1.840,
1482.08679,12.598,2560.65869,0.840,
1482.17834,12.598,2560.75024,0.840,
1482.26978,11.598,2560.84155,0.840,
1482.36133,11.598,2560.93311,0.840,
1482.45288,12.598,2561.02466,1.840,
1482.54431,11.598,2561.11621,1.840,
1482.63586,11.598,2561.20776,0.840,
1482.72742,11.598,2561.29932,1.840,
1482.81897,12.598,2561.39087,0.840,
1482.91040,11.598,2561.48242,1.840,
1483.00195,11.598,2561.57373,0.840,
1483.09351,12.598,2561.66528,1.840,
1483.18506,12.598,2561.75684,0.840,
1483.27649,11.598,2561.84839,0.840,
1483.36804,12.598,2561.93994,0.840,
1483.45959,11.598,2562.03149,1.840,
1483.55115,12.598,2562.12305,1.840,
1483.64258,12.598,2562.21436,1.840,
1483.73413,12.598,2562.30591,1.840,
1483.82568,11.598,2562.39746,1.840,
1483.91724,11.598,2562.48901,1.840,
1484.00867,12.598,2562.58057,1.840,
1484.10022,12.598,2562.67212,1.840,
1484.19177,11.598,2562.76367,0.840,
1484.28333,12.598,2562.85522,0.840,
1484.37476,12.598,2562.94653,0.840,
1484.46631,12.598,2563.03809,0.840,
1484.55786,12.598,2563.12964,0.840,
1484.64929,12.598,2563.22119,0.840,
1484.74084,12.598,2563.31274,0.840,
1484.83240,12.598,2563.40430,1.840,
1484.92395,12.598,2563.49585,1.840,
1485.01538,12.598,2563.58740,0.840,
1485.10693,11.598,2563.67871,1.840,
1485.19849,11.598,2563.77026,1.840,
1485.29004,12.598,2563.86182,1.840,
1485.38147,12.598,2563.95337,1.840,
1485.47302,12.598,2564.04492,0.840,
1485.56458,11.598,2564.13647,0.840,
1485.65613,11.598,2564.22803,0.840,
1485.74756,12.598,2564.31934,0.840,
1485.83911,11.598,2564.41089,0.840,
1485.93066,11.598,2564.50244,0.840,
1486.02222,11.598,2564.59399,0.840,
1486.11365,11.598,2564.68555,0.840,
1486.20520,12.598,2564.77710,0.840,
1486.29675,12.598,2564.86865,0.840,
1486.38818,12.598,2564.96021,0.840,
1486.47974,11.598,2565.05151,0.840,
1486.57129,12.598,2565.14307,0.840,
1486.66284,11.598,2565.23462,0.840,
1486.75427,12.598,2565.32617,0.840,
1486.84583,12.598,2565.41772,0.840,
1486.93738,11.598,2565.50928,1.840,
1487.02893,11.598,2565.60083,1.840,
1487.12036,12.598,2565.69214,1.840,
1487.21191,12.598,2565.78369,0.840,
1487.30347,12.598,2565.87524,0.840,
1487.39502,12.598,2565.96680,1.840,
1487.48645,12.598,2566.05835,0.840,
1487.57800,11.598,2566.14990,0.840,
1487.66956,12.598,2566.24146,0.840,
1487.76111,12.598,2566.33301,0.840,
1487.85254,12.598,2566.42432,1.840,
1487.94409,11.598,2566.51587,0.840,
1488.03564,12.598,2566.60742,0.840,
1488.12720,12.598,2566.69897,1.840,
1488.21863,12.598,2566.79053,0.840,
1488.31018,12.598,2566.88208,1.840,
1488.40173,12.598,2566.97363,0.840,
1488.49316,12.598,2567.06519,1.840,
1488.58472,12.598,2567.15649,0.840,
1488.67627,13.598,2567.24805,0.840,
1488.76782,12.598,2567.33960,0.840,
1488.85925,12.598,2567.43115,0.840,
1488.95081,12.598,2567.52271,0.840,
1489.04236,12.598,2567.61426,0.840,
1489.13391,12.598,2567.70581,0.840,
1489.22534,12.598,2567.79712,0.840,
1489.31689,12.598,2567.88867,1.840,
1489.40845,12.598,2567.98022,1.840,
1489.50000,12.598,2568.07178,0.840,
1489.59143,12.598,2568.16333,1.840,
1489.68298,12.598,2568.25488,0.840,
1489.77454,12.598,2568.34644,0.840,
1489.86609,12.598,2568.43799,0.840,
1489.95752,12.598,2568.52930,1.840,
1490.04907,11.598,2568.62085,1.840,
1490.14063,13.598,2568.71240,1.840,
1490.23206,12.598,2568.80396,0.840,
1490.32361,12.598,2568.89551,0.840,
1490.41516,13.598,2568.98706,0.840,
1490.50671,13.598,2569.07861,1.840,
1490.59814,12.598,2569.17017,0.840,
1490.68970,12.598,2569.26147,0.840,
1490.78125,12.598,2569.35303,1.840,
1490.87280,12.598,2569.44458,1.840,
1490.96423,12.598,2569.53613,0.840,
1491.05579,12.598,2569.62769,0.840,
1491.14734,12.598,2569.71924,1.840,
1491.23889,12.598,2569.81079,0.840,
1491.33032,12.598,2569.90210,0.840,
1491.42188,12.598,2569.99365,1.840,
1491.51343,12.598,2570.08521,1.840,
1491.60498,12.598,2570.17676,0.840,
1491.69641,12.598,2570.26831,1.840,
1491.78796,12.598,2570.35986,0.840,
1491.87952,12.598,2570.45142,0.840,
1491.97095,12.598,2570.54297,1.840,
1492.06250,12.598,2570.63428,1.840,
1492.15405,12.598,2570.72583,1.840,
1492.24561,12.598,2570.81738,1.840,
1492.33704,12.598,2570.90894,1.840,
1492.42859,12.598,2571.00049,0.840,
1492.52014,12.598,2571.09204,0.840,
1492.61169,12.598,2571.18359,0.840,
1492.70313,12.598,2571.27515,1.840,
1492.79468,12.598,2571.36646,1.840,
1492.88623,12.598,2571.45801,1.840,
1492.97778,12.598,2571.54956,1.840,
1493.06921,13.598,2571.64111,0.840,
1493.16077,12.598,2571.73267,0.840,
1493.25232,13.598,2571.82422,1.840,
1493.34387,13.598,2571.91577,1.840,
1493.43530,13.598,2572.00708,1.840,
1493.52686,13.598,2572.09863,1.840,
1493.61841,13.598,2572.19019,1.840,
1493.70996,12.598,2572.28174,1.840,
1493.80139,13.598,2572.37329,1.840,
1493.89294,13.598,2572.46484,0.840,
1493.98450,12.598,2572.55640,0.840,
1494.07593,12.598,2572.64795,0.840,
1494.16748,13.598,2572.73926,0.840,
1494.25903,12.598,2572.83081,0.840,
1494.35059,13.598,2572.92236,-0.160,
1494.44202,13.598,2573.01392,0.840,
1494.53357,13.598,2573.10547,0.840,
1494.62512,13.598,2573.19702,0.840,
1494.71667,12.598,2573.28857,-0.160,
1494.80811,13.598,2573.37988,0.840,
1494.89966,12.598,2573.47144,0.840,
1494.99121,12.598,2573.56299,-0.160,
1495.08276,12.598,2573.65454,0.840,
1495.17419,12.598,2573.74609,0.840,
1495.26575,12.598,2573.83765,-0.160,
1495.35730,12.598,2573.92920,-0.160,
1495.44885,12.598,2574.02075,0.840,
1495.54028,12.598,2574.11206,0.840,
1495.63184,12.598,2574.20361,0.840,
1495.72339,12.598,2574.29517,0.840,
1495.81482,12.598,2574.38672,0.840,
1495.90637,12.598,2574.47827,0.840,
1495.99792,13.598,2574.56982,0.840,
1496.08948,12.598,2574.66138,0.840,
1496.18091,12.598,2574.75293,1.840,
1496.27246,13.598,2574.84424,1.840,
1496.36401,13.598,2574.93579,2.840,
1496.45557,12.598,2575.02734,1.840,
1496.54700,12.598,2575.11890,1.840,
1496.63855,12.598,2575.21045,2.840,
1496.73010,12.598,2575.30200,2.840,
1496.82166,12.598,2575.39355,1.840,
1496.91309,12.598,2575.48486,1.840,
1497.00464,12.598,2575.57642,1.840,
1497.09619,13.598,2575.66797,0.840,
1497.18774,13.598,2575.75952,0.840,
1497.27917,13.598,2575.85107,1.840,
1497.37073,12.598,2575.94263,1.840,
1497.46228,13.598,2576.03418,0.840,
1497.55383,12.598,2576.12573,0.840,
1497.64526,13.598,2576.21704,0.840,
1497.73682,12.598,2576.30859,0.840,
1497.82837,13.598,2576.40015,0.840,
1497.91980,12.598,2576.49170,0.840,
1498.01135,12.598,2576.58325,0.840,
1498.10291,12.598,2576.67480,1.840,
1498.19446,12.598,2576.76636,0.840,
1498.28589,12.598,2576.85791,0.840,
1498.37744,12.598,2576.94922,0.840,
1498.46899,12.598,2577.04077,0.840,
1498.56055,13.598,2577.13232,-0.160,
1498.65198,12.598,2577.22388,0.840,
1498.74353,12.598,2577.31543,0.840,
1498.83508,13.598,2577.40698,0.840,
1498.92664,13.598,2577.49854,0.840,
1499.01807,13.598,2577.58984,0.840,
1499.10962,13.598,2577.68140,0.840,
1499.20117,13.598,2577.77295,-0.160,
1499.29272,13.598,2577.86450,-0.160,
1499.38416,13.598,2577.95605,0.840,
1499.47571,14.598,2578.04761,0.840,
1499.56726,13.598,2578.13916,0.840,
1499.65869,13.598,2578.23071,0.840,
1499.75024,13.598,2578.32202,0.840,
1499.84180,13.598,2578.41357,0.840,
1499.93335,13.598,2578.50513,0.840,
1500.02478,13.598,2578.59668,0.840,
1500.11633,12.598,2578.68823,0.840,
1500.20789,12.598,2578.77979,0.840,
1500.29944,13.598,2578.87134,0.840,
1500.39087,13.598,2578.96265,0.840,
1500.48242,13.598,2579.05420,-0.160,
1500.57397,13.598,2579.14575,0.840,
1500.66553,13.598,2579.23730,0.840,
1500.75696,13.598,2579.32886,-0.160,
1500.84851,13.598,2579.42041,0.840,
1500.94006,13.598,2579.51196,0.840,
1501.03162,13.598,2579.60352,1.840,
1501.12305,13.598,2579.69482,0.840,
1501.21460,13.598,2579.78638,0.840,
1501.30615,13.598,2579.87793,-0.160,
1501.39758,13.598,2579.96948,0.840,
1501.48914,14.598,2580.06104,0.840,
1501.58069,13.598,2580.15259,0.840,
1501.67224,13.598,2580.24414,0.840,
1501.76367,13.598,2580.33569,-0.160,
1501.85522,14.598,2580.42700,0.840,
1501.94678,13.598,2580.51855,-0.160,
1502.03833,13.598,2580.61011,0.840,
1502.12976,13.598,2580.70166,0.840,
1502.22131,13.598,2580.79321,-0.160,
1502.31287,13.598,2580.88477,0.840,
1502.40442,13.598,2580.97632,-0.160,
1502.49585,13.598,2581.06763,1.840,
1502.58740,13.598,2581.15918,0.840,
1502.67896,13.598,2581.25073,0.840,
1502.77051,14.598,2581.34229,0.840,
1502.86194,13.598,2581.43384,0.840,
1502.95349,13.598,2581.52539,0.840,
1503.04504,13.598,2581.61694,0.840,
1503.13660,13.598,2581.70850,0.840,
1503.22803,13.598,2581.79980,0.840,
1503.31958,13.598,2581.89136,0.840,
1503.41113,13.598,2581.98291,0.840,
1503.50256,13.598,2582.07446,0.840,
1503.59412,13.598,2582.16602,0.840,
1503.68567,13.598,2582.25757,0.840,
1503.77722,13.598,2582.34912,0.840,
1503.86865,13.598,2582.44067,-0.160,
1503.96021,13.598,2582.53198,0.840,
1504.05176,13.598,2582.62354,0.840,
1504.14331,13.598,2582.71509,0.840,
1504.23474,13.598,2582.80664,0.840,
1504.32629,13.598,2582.89819,0.840,
1504.41785,13.598,2582.98975,0.840,
1504.50940,13.598,2583.08130,-0.160,
1504.60083,13.598,2583.17261,0.840,
1504.69238,13.598,2583.26416,0.840,
1504.78394,14.598,2583.35571,-0.160,
1504.87549,13.598,2583.44727,0.840,
1504.96692,13.598,2583.53882,0.840,
1505.05847,13.598,2583.63037,-0.160,
1505.15002,13.598,2583.72192,0.840,
1505.24146,14.598,2583.81348,0.840,
1505.33301,13.598,2583.90479,-0.160,
1505.42456,13.598,2583.99634,0.840,
1505.51611,13.598,2584.08789,0.840,
1505.60754,13.598,2584.17944,0.840,
1505.69910,13.598,2584.27100,-0.160,
1505.79065,13.598,2584.36255,0.840,
1505.88220,13.598,2584.45410,0.840,
1505.97363,13.598,2584.54541,0.840,
1506.06519,13.598,2584.63696,0.840,
1506.15674,13.598,2584.72852,-0.160,
1506.24829,14.598,2584.82007,-0.160,
1506.33972,13.598,2584.91162,0.840,
1506.43127,13.598,2585.00317,0.840,
1506.52283,13.598,2585.09473,0.840,
1506.61438,13.598,2585.18628,0.840,
1506.70581,13.598,2585.27759,0.840,
1506.79736,13.598,2585.36914,-0.160,
1506.88892,13.598,2585.46069,0.840,
1506.98047,14.598,2585.55225,0.840,
1507.07190,13.598,2585.64380,0.840,
1507.16345,13.598,2585.73535,0.840,
1507.25500,13.598,2585.82690,0.840,
1507.34644,13.598,2585.91846,0.840,
1507.43799,13.598,2586.00977,0.840,
1507.52954,13.598,2586.10132,0.840,
1507.62109,13.598,2586.19287,0.840,
1507.71252,14.598,2586.28442,0.840,
1507.80408,13.598,2586.37598,0.840,
1507.89563,13.598,2586.46753,0.840,
1507.98718,13.598,2586.55908,0.840,
1508.07861,13.598,2586.65039,0.840,
1508.17017,13.598,2586.74194,0.840,
1508.26172,13.598,2586.83350,0.840,
1508.35327,13.598,2586.92505,0.840,
1508.44470,13.598,2587.01660,0.840,
1508.53625,14.598,2587.10815,0.840,
1508.62781,13.598,2587.19971,1.840,
1508.71936,13.598,2587.29126,0.840,
1508.81079,13.598,2587.38257,0.840,
1508.90234,13.598,2587.47412,0.840,
1508.99390,13.598,2587.56567,0.840,
1509.08533,13.598,2587.65723,-0.160,
1509.17688,14.598,2587.74878,0.840,
1509.26843,14.598,2587.84033,-0.160,
1509.35999,13.598,2587.93188,-0.160,
1509.45142,14.598,2588.02344,0.840,
1509.54297,15.598,2588.11475,0.840,
1509.63452,14.598,2588.20630,-0.160,
1509.72607,14.598,2588.29785,-0.160,
1509.81750,15.598,2588.38940,0.840,
1509.90906,14.598,2588.48096,0.840,
1510.00061,14.598,2588.57251,0.840,
1510.09216,14.598,2588.66406,0.840,
1510.18359,14.598,2588.75537,0.840,
1510.27515,13.598,2588.84692,0.840,
1510.36670,14.598,2588.93848,1.840,
1510.45825,14.598,2589.03003,0.840,
1510.54968,13.598,2589.12158,0.840,
1510.64124,14.598,2589.21313,-0.160,
1510.73279,14.598,2589.30469,-0.160,
1510.82422,14.598,2589.39624,-0.160,
1510.91577,14.598,2589.48755,-0.160,
1511.00732,14.598,2589.57910,0.840,
1511.09888,14.598,2589.67065,0.840,
1511.19031,13.598,2589.76221,-0.160,
1511.28186,14.598,2589.85376,0.840,
1511.37341,14.598,2589.94531,0.840,
1511.46497,13.598,2590.03687,-0.160,
1511.55640,14.598,2590.12842,-0.160,
1511.64795,14.598,2590.21973,-0.160,
1511.73950,14.598,2590.31128,-0.160,
1511.83105,14.598,2590.40283,-1.160,
1511.92249,14.598,2590.49438,-0.160,
1512.01404,14.598,2590.58594,-1.160,
1512.10559,14.598,2590.67749,-1.160,
1512.19714,14.598,2590.76904,-1.160,
1512.28857,14.598,2590.86035,-1.160,
1512.38013,13.598,2590.95190,-1.160,
1512.47168,13.598,2591.04346,-1.160,
1512.56323,13.598,2591.13501,-1.160,
1512.65466,13.598,2591.22656,-0.160,
1512.74622,13.598,2591.31812,-1.160,
1512.83777,13.598,2591.40967,-1.160,
1512.92920,13.598,2591.50122,-1.160,
1513.02075,13.598,2591.59253,-0.160,
1513.11230,13.598,2591.68408,-0.160,
1513.20386,13.598,2591.77563,-0.160,
1513.29529,13.598,2591.86719,-0.160,
1513.38684,13.598,2591.95874,-0.160,
1513.47839,13.598,2592.05029,-0.160,
1513.56995,14.598,2592.14185,-0.160,
1513.66138,13.598,2592.23315,-0.160,
1513.75293,14.598,2592.32471,-0.160,
1513.84448,14.598,2592.41626,0.840,
1513.93604,14.598,2592.50781,-0.160,
1514.02747,14.598,2592.59937,0.840,
1514.11902,14.598,2592.69092,1.840,
1514.21057,14.598,2592.78247,1.840,
1514.30212,14.598,2592.87402,1.840,
1514.39355,14.598,2592.96533,2.840,
1514.48511,13.598,2593.05688,2.840,
1514.57666,13.598,2593.14844,1.840,
1514.66809,14.598,2593.23999,2.840,
1514.75964,13.598,2593.33154,1.840,
1514.85120,13.598,2593.42310,1.840,
1514.94275,13.598,2593.51465,1.840,
1515.03418,14.598,2593.60620,1.840,
1515.12573,14.598,2593.69751,1.840,
1515.21729,13.598,2593.78906,0.840,
1515.30884,14.598,2593.88062,1.840,
1515.40027,14.598,2593.97217,0.840,
1515.49182,14.598,2594.06372,0.840,
1515.58337,14.598,2594.15527,0.840,
1515.67493,14.598,2594.24683,0.840,
1515.76636,14.598,2594.33813,0.840,
1515.85791,14.598,2594.42969,0.840,
1515.94946,14.598,2594.52124,0.840,
1516.04102,14.598,2594.61279,0.840,
1516.13245,13.598,2594.70435,0.840,
1516.22400,14.598,2594.79590,0.840,
1516.31555,14.598,2594.88745,0.840,
1516.40710,14.598,2594.97900,0.840,
1516.49854,15.598,2595.07031,-0.160,
1516.59009,14.598,2595.16187,0.840,
1516.68164,14.598,2595.25342,-0.160,
1516.77307,14.598,2595.34497,-0.160,
1516.86462,14.598,2595.43652,-0.160,
1516.95618,14.598,2595.52808,-0.160,
1517.04773,14.598,2595.61963,-0.160,
1517.13916,14.598,2595.71118,0.840,
1517.23071,14.598,2595.80249,-0.160,
1517.32227,13.598,2595.89404,0.840,
1517.41382,14.598,2595.98560,-0.160,
1517.50525,13.598,2596.07715,0.840,
1517.59680,14.598,2596.16870,0.840,
1517.68835,14.598,2596.26025,-0.160,
1517.77991,14.598,2596.35181,0.840,
1517.87134,14.598,2596.44312,-0.160,
1517.96289,14.598,2596.53467,-0.160,
1518.05444,14.598,2596.62622,-0.160,
1518.14600,14.598,2596.71777,0.840,
1518.23743,14.598,2596.80933,-0.160,
1518.32898,14.598,2596.90088,-0.160,
1518.42053,14.598,2596.99243,0.840,
1518.51196,14.598,2597.08398,-0.160,
1518.60352,14.598,2597.17529,-0.160,
1518.69507,14.598,2597.26685,-0.160,
1518.78662,14.598,2597.35840,0.840,
1518.87805,14.598,2597.44995,0.840,
1518.96960,14.598,2597.54150,-0.160,
1519.06116,14.598,2597.63306,-0.160,
1519.15271,14.598,2597.72461,0.840,
1519.24414,14.598,2597.81592,0.840,
1519.33569,14.598,2597.90747,-0.160,
1519.42725,14.598,2597.99902,0.840,
1519.51880,14.598,2598.09058,-0.160,
1519.61023,14.598,2598.18213,-0.160,
1519.70178,14.598,2598.27368,0.840,
1519.79333,14.598,2598.36523,0.840,
1519.88489,14.598,2598.45679,-0.160,
1519.97632,14.598,2598.54810,0.840,
1520.06787,14.598,2598.63965,0.840,
1520.15942,14.598,2598.73120,-0.160,
1520.25085,14.598,2598.82275,0.840,
1520.34241,14.598,2598.91431,0.840,
1520.43396,14.598,2599.00586,-0.160,
1520.52551,14.598,2599.09741,0.840,
1520.61694,14.598,2599.18896,0.840,
1520.70850,13.598,2599.28027,0.840,
1520.80005,14.598,2599.37183,0.840,
1520.89160,14.598,2599.46338,0.840,
1520.98303,13.598,2599.55493,0.840,
1521.07458,14.598,2599.64648,-0.160,
1521.16614,14.598,2599.73804,0.840,
1521.25769,14.598,2599.82959,0.840,
1521.34912,14.598,2599.92090,0.840,
1521.44067,14.598,2600.01245,0.840,
1521.53223,14.598,2600.10400,0.840,
1521.62378,14.598,2600.19556,0.840,
1521.71521,14.598,2600.28711,0.840,
1521.80676,14.598,2600.37866,0.840,
1521.89832,14.598,2600.47021,0.840,
1521.98987,14.598,2600.56177,-0.160,
1522.08130,14.598,2600.65308,0.840,
1522.17285,14.598,2600.74463,0.840,
1522.26440,14.598,2600.83618,-0.160,
1522.35583,14.598,2600.92773,0.840,
1522.44739,14.598,2601.01929,0.840,
1522.53894,13.598,2601.11084,-0.160,
1522.63049,14.598,2601.20239,0.840,
1522.72192,14.598,2601.29395,0.840,
1522.81348,14.598,2601.38525,0.840,
1522.90503,14.598,2601.47681,0.840,
1522.99658,14.598,2601.56836,0.840,
1523.08801,14.598,2601.65991,0.840,
1523.17957,13.598,2601.75146,0.840,
1523.27112,14.598,2601.84302,0.840,
1523.36267,14.598,2601.93457,0.840,
1523.45410,13.598,2602.02588,-0.160,
1523.54565,14.598,2602.11743,-0.160,
1523.63721,14.598,2602.20898,0.840,
1523.72876,14.598,2602.30054,0.840,
1523.82019,14.598,2602.39209,0.840,
1523.91174,14.598,2602.48364,0.840,
1524.00330,14.598,2602.57520,0.840,
1524.09473,14.598,2602.66675,-0.160,
1524.18628,14.598,2602.75806,-0.160,
1524.27783,14.598,2602.84961,0.840,
1524.36938,14.598,2602.94116,0.840,
1524.46082,15.598,2603.03271,0.840,
1524.55237,14.598,2603.12427,0.840,
1524.64392,14.598,2603.21582,-0.160,
1524.73547,14.598,2603.30737,-0.160,
1524.82690,14.598,2603.39868,0.840,
1524.91846,14.598,2603.49023,0.840,
1525.01001,14.598,2603.58179,0.840,
1525.10156,14.598,2603.67334,-0.160,
1525.19299,14.598,2603.76489,0.840,
1525.28455,14.598,2603.85645,0.840,
1525.37610,14.598,2603.94800,-0.160,
1525.46765,14.598,2604.03955,0.840,
1525.55908,14.598,2604.13086,0.840,
1525.65063,14.598,2604.22241,-0.160,
1525.74219,14.598,2604.31396,0.840,
1525.83374,14.598,2604.40552,-0.160,
1525.92517,14.598,2604.49707,-0.160,
1526.01672,14.598,2604.58862,-0.160,
1526.10828,14.598,2604.68018,0.840,
1526.19971,14.598,2604.77173,0.840,
1526.29126,14.598,2604.86304,-0.160,
1526.38281,14.598,2604.95459,0.840,
1526.47437,14.598,2605.04614,-0.160,
1526.56580,14.598,2605.13770,0.840,
1526.65735,14.598,2605.22925,0.840,
1526.74890,15.598,2605.32080,-0.160,
1526.84045,15.598,2605.41235,-0.160,
1526.93188,15.598,2605.50366,0.840,
1527.02344,15.598,2605.59521,0.840,
1527.11499,15.598,2605.68677,-0.160,
1527.20654,15.598,2605.77832,-0.160,
1527.29797,15.598,2605.86987,0.840,
1527.38953,15.598,2605.96143,-0.160,
1527.48108,15.598,2606.05298,-0.160,
1527.57263,15.598,2606.14453,0.840,
1527.66406,14.598,2606.23584,0.840,
1527.75562,15.598,2606.32739,-0.160,
1527.84717,15.598,2606.41895,0.840,
1527.93860,15.598,2606.51050,0.840,
1528.03015,14.598,2606.60205,-0.160,
1528.12170,14.598,2606.69360,-0.160,
1528.21326,14.598,2606.78516,0.840,
1528.30469,14.598,2606.87671,0.840,
1528.39624,14.598,2606.96802,-0.160,
1528.48779,14.598,2607.05957,0.840,
1528.57935,15.598,2607.15112,0.840,
1528.67078,14.598,2607.24268,0.840,
1528.76233,14.598,2607.33423,0.840,
1528.85388,15.598,2607.42578,0.840,
1528.94543,14.598,2607.51733,0.840,
1529.03687,15.598,2607.60864,0.840,
1529.12842,15.598,2607.70020,0.840,
1529.21997,15.598,2607.79175,0.840,
1529.31152,15.598,2607.88330,-0.160,
1529.40295,14.598,2607.97485,0.840,
1529.49451,14.598,2608.06641,0.840,
1529.58606,14.598,2608.15796,-0.160,
1529.67749,15.598,2608.24951,-0.160,
1529.76904,14.598,2608.34082,-0.160,
1529.86060,14.598,2608.43237,-1.160,
1529.95215,14.598,2608.52393,-1.160,
1530.04358,13.598,2608.61548,-2.160,
1530.13513,13.598,2608.70703,-1.160,
1530.22668,13.598,2608.79858,-2.160,
1530.31824,13.598,2608.89014,-1.160,
1530.40967,14.598,2608.98169,-2.160,
1530.50122,13.598,2609.07300,-2.160,
1530.59277,13.598,2609.16455,-2.160,
1530.68433,14.598,2609.25610,-1.160,
1530.77576,13.598,2609.34766,-1.160,
1530.86731,14.598,2609.43921,-1.160,
1530.95886,14.598,2609.53076,-0.160,
1531.05042,14.598,2609.62231,-1.160,
1531.14185,15.598,2609.71362,-0.160,
1531.23340,14.598,2609.80518,-0.160,
1531.32495,14.598,2609.89673,-0.160,
1531.41650,14.598,2609.98828,-1.160,
1531.50793,14.598,2610.07983,-0.160,
1531.59949,14.598,2610.17139,-0.160,
1531.69104,14.598,2610.26294,-0.160,
1531.78247,14.598,2610.35449,0.840,
1531.87402,14.598,2610.44580,-0.160,
1531.96558,14.598,2610.53735,0.840,
1532.05713,14.598,2610.62891,0.840,
1532.14856,14.598,2610.72046,0.840,
1532.24011,14.598,2610.81201,1.840,
1532.33167,14.598,2610.90356,1.840,
1532.42322,14.598,2610.99512,1.840,
1532.51465,15.598,2611.08643,1.840,
1532.60620,15.598,2611.17798,1.840,
1532.69775,14.598,2611.26953,1.840,
1532.78931,14.598,2611.36108,1.840,
1532.88074,14.598,2611.45264,1.840,
1532.97229,14.598,2611.54419,1.840,
1533.06384,14.598,2611.63574,1.840,
1533.15540,14.598,2611.72729,1.840,
1533.24683,14.598,2611.81860,1.840,
1533.33838,14.598,2611.91016,0.840,
1533.42993,14.598,2612.00171,1.840,
1533.52136,14.598,2612.09326,1.840,
1533.61292,13.598,2612.18481,0.840,
1533.70447,14.598,2612.27637,0.840,
1533.79602,14.598,2612.36792,0.840,
1533.88745,14.598,2612.45947,0.840,
1533.97900,14.598,2612.55078,0.840,
1534.07056,14.598,2612.64233,0.840,
1534.16211,13.598,2612.73389,0.840,
1534.25354,14.598,2612.82544,0.840,
1534.34509,14.598,2612.91699,0.840,
1534.43665,14.598,2613.00854,0.840,
1534.52820,13.598,2613.10010,0.840,
1534.61963,14.598,2613.19141,0.840,
1534.71118,14.598,2613.28296,1.840,
1534.80273,14.598,2613.37451,0.840,
1534.89429,13.598,2613.46606,0.840,
1534.98572,14.598,2613.55762,0.840,
1535.07727,13.598,2613.64917,0.840,
1535.16882,13.598,2613.74072,0.840,
1535.26038,14.598,2613.83228,0.840,
1535.35181,14.598,2613.92358,0.840,
1535.44336,14.598,2614.01514,0.840,
1535.53491,14.598,2614.10669,-0.160,
1535.62634,14.598,2614.19824,0.840,
1535.71790,14.598,2614.28979,0.840,
1535.80945,14.598,2614.38135,0.840,
1535.90100,14.598,2614.47290,0.840,
1535.99243,13.598,2614.56445,0.840,
1536.08398,14.598,2614.65576,0.840,
1536.17554,14.598,2614.74731,1.840,
1536.26709,14.598,2614.83887,0.840,
1536.35852,14.598,2614.93042,0.840,
1536.45007,14.598,2615.02197,0.840,
1536.54163,14.598,2615.11353,0.840,
1536.63318,14.598,2615.20508,-0.160,
1536.72461,14.598,2615.29639,0.840,
1536.81616,14.598,2615.38794,0.840,
1536.90771,14.598,2615.47949,1.840,
1536.99927,14.598,2615.57104,0.840,
1537.09070,14.598,2615.66260,0.840,
1537.18225,14.598,2615.75415,0.840,
1537.27380,14.598,2615.84570,0.840,
1537.36523,14.598,2615.93726,0.840,
1537.45679,14.598,2616.02856,0.840,
1537.54834,14.598,2616.12012,-0.160,
1537.63989,14.598,2616.21167,0.840,
1537.73132,15.598,2616.30322,0.840,
1537.82288,14.598,2616.39478,0.840,
1537.91443,14.598,2616.48633,0.840,
1538.00598,14.598,2616.57788,0.840,
1538.09741,13.598,2616.66919,0.840,
1538.18896,14.598,2616.76074,0.840,
1538.28052,14.598,2616.85229,1.840,
1538.37207,14.598,2616.94385,0.840,
1538.46350,14.598,2617.03540,0.840,
1538.55505,14.598,2617.12695,0.840,
1538.64661,14.598,2617.21851,0.840,
1538.73816,14.598,2617.31006,0.840,
1538.82959,13.598,2617.40137,0.840,
1538.92114,14.598,2617.49292,0.840,
1539.01270,14.598,2617.58447,0.840,
1539.10413,13.598,2617.67603,1.840,
1539.19568,14.598,2617.76758,0.840,
1539.28723,14.598,2617.85913,0.840,
1539.37878,14.598,2617.95068,1.840,
1539.47021,13.598,2618.04224,0.840,
1539.56177,14.598,2618.13354,1.840,
1539.65332,14.598,2618.22510,0.840,
1539.74487,14.598,2618.31665,0.840,
1539.83630,14.598,2618.40820,0.840,
1539.92786,15.598,2618.49976,0.840,
1540.01941,14.598,2618.59131,0.840,
1540.11096,14.598,2618.68286,0.840,
1540.20239,14.598,2618.77417,0.840,
1540.29395,13.598,2618.86572,0.840,
1540.38550,14.598,2618.95728,0.840,
1540.47705,14.598,2619.04883,0.840,
1540.56848,14.598,2619.14038,1.840,
1540.66003,14.598,2619.23193,0.840,
1540.75159,14.598,2619.32349,1.840,
1540.84314,14.598,2619.41504,1.840,
1540.93457,14.598,2619.50635,0.840,
1541.02612,14.598,2619.59790,0.840,
1541.11768,14.598,2619.68945,1.840,
1541.20911,14.598,2619.78101,0.840,
1541.30066,14.598,2619.87256,0.840,
1541.39221,15.598,2619.96411,0.840,
1541.48376,14.598,2620.05566,0.840,
1541.57520,14.598,2620.14722,0.840,
1541.66675,14.598,2620.23853,0.840,
1541.75830,14.598,2620.33008,0.840,
1541.84985,14.598,2620.42163,0.840,
1541.94128,14.598,2620.51318,0.840,
1542.03284,14.598,2620.60474,1.840,
1542.12439,14.598,2620.69629,0.840,
1542.21594,14.598,2620.78784,0.840,
1542.30737,14.598,2620.87915,0.840,
1542.39893,14.598,2620.97070,0.840,
1542.49048,14.598,2621.06226,-0.160,
1542.58203,14.598,2621.15381,0.840,
1542.67346,14.598,2621.24536,0.840,
1542.76501,14.598,2621.33691,0.840,
1542.85657,14.598,2621.42847,0.840,
1542.94800,14.598,2621.52002,0.840,
1543.03955,14.598,2621.61133,0.840,
1543.13110,15.598,2621.70288,0.840,
1543.22266,14.598,2621.79443,0.840,
1543.31409,15.598,2621.88599,0.840,
1543.40564,14.598,2621.97754,0.840,
1543.49719,15.598,2622.06909,1.840,
1543.58875,14.598,2622.16064,0.840,
1543.68018,14.598,2622.25195,0.840,
1543.77173,14.598,2622.34351,0.840,
1543.86328,14.598,2622.43506,1.840,
1543.95483,14.598,2622.52661,0.840,
1544.04626,14.598,2622.61816,0.840,
1544.13782,15.598,2622.70972,0.840,
1544.22937,14.598,2622.80127,0.840,
1544.32092,15.598,2622.89282,0.840,
1544.41235,15.598,2622.98413,0.840,
1544.50391,15.598,2623.07568,1.840,
1544.59546,15.598,2623.16724,1.840,
1544.68689,15.598,2623.25879,0.840,
1544.77844,15.598,2623.35034,1.840,
1544.87000,15.598,2623.44189,0.840,
1544.96155,15.598,2623.53345,1.840,
1545.05298,15.598,2623.62500,1.840,
1545.14453,15.598,2623.71631,1.840,
1545.23608,15.598,2623.80786,0.840,
1545.32764,15.598,2623.89941,0.840,
1545.41907,15.598,2623.99097,0.840,
1545.51062,15.598,2624.08252,0.840,
1545.60217,15.598,2624.17407,0.840,
1545.69373,14.598,2624.26563,1.840,
1545.78516,15.598,2624.35693,0.840,
1545.87671,14.598,2624.44849,0.840,
1545.96826,15.598,2624.54004,0.840,
1546.05981,14.598,2624.63159,0.840,
1546.15125,14.598,2624.72314,0.840,
1546.24280,14.598,2624.81470,0.840,
1546.33435,14.598,2624.90625,0.840,
1546.42590,13.598,2624.99780,1.840,
1546.51733,13.598,2625.08911,0.840,
1546.60889,13.598,2625.18066,0.840,
1546.70044,13.598,2625.27222,0.840,
1546.79187,13.598,2625.36377,0.840,
1546.88342,13.598,2625.45532,1.840,
1546.97498,14.598,2625.54688,1.840,
1547.06653,14.598,2625.63843,0.840,
1547.15796,14.598,2625.72998,0.840,
1547.24951,15.598,2625.82129,0.840,
1547.34106,15.598,2625.91284,0.840,
1547.43262,14.598,2626.00439,0.840,
1547.52405,15.598,2626.09595,0.840,
1547.61560,14.598,2626.18750,1.840,
1547.70715,15.598,2626.27905,0.840,
1547.79871,15.598,2626.37061,1.840,
1547.89014,15.598,2626.46191,1.840,
1547.98169,15.598,2626.55347,1.840,
1548.07324,14.598,2626.64502,1.840,
1548.16479,15.598,2626.73657,1.840,
1548.25623,15.598,2626.82813,0.840,
1548.34778,15.598,2626.91968,1.840,
1548.43933,14.598,2627.01123,0.840,
1548.53076,15.598,2627.10278,1.840,
1548.62231,15.598,2627.19409,0.840,
1548.71387,15.598,2627.28564,0.840,
1548.80542,15.598,2627.37720,1.840,
1548.89685,14.598,2627.46875,0.840,
1548.98840,15.598,2627.56030,0.840,
1549.07996,15.598,2627.65186,0.840,
1549.17151,15.598,2627.74341,0.840,
1549.26294,15.598,2627.83496,0.840,
1549.35449,15.598,2627.92627,0.840,
1549.44604,15.598,2628.01782,0.840,
1549.53760,15.598,2628.10938,0.840,
1549.62903,15.598,2628.20093,1.840,
1549.72058,14.598,2628.29248,0.840,
1549.81213,14.598,2628.38403,0.840,
1549.90369,15.598,2628.47559,0.840,
1549.99512,15.598,2628.56689,1.840,
1550.08667,15.598,2628.65845,1.840,
1550.17822,15.598,2628.75000,0.840,
1550.26978,15.598,2628.84155,0.840,
1550.36121,15.598,2628.93311,0.840,
1550.45276,15.598,2629.02466,-0.160,
1550.54431,15.598,2629.11621,-0.160,
1550.63574,15.598,2629.20776,0.840,
1550.72729,15.598,2629.29907,0.840,
1550.81885,15.598,2629.39063,0.840,
1550.91040,14.598,2629.48218,0.840,
1551.00183,15.598,2629.57373,0.840,
1551.09338,15.598,2629.66528,0.840,
1551.18494,15.598,2629.75684,1.840,
1551.27649,14.598,2629.84839,0.840,
1551.36792,14.598,2629.93970,0.840,
1551.45947,15.598,2630.03125,0.840,
1551.55103,15.598,2630.12280,0.840,
1551.64258,15.598,2630.21436,0.840,
1551.73401,15.598,2630.30591,0.840,
1551.82556,15.598,2630.39746,0.840,
1551.91711,14.598,2630.48901,0.840,
1552.00867,15.598,2630.58057,0.840,
1552.10010,15.598,2630.67188,1.840,
1552.19165,15.598,2630.76343,0.840,
1552.28320,14.598,2630.85498,1.840,
1552.37463,15.598,2630.94653,0.840,
1552.46619,15.598,2631.03809,0.840,
1552.55774,15.598,2631.12964,1.840,
1552.64929,14.598,2631.22119,1.840,
1552.74072,15.598,2631.31274,1.840,
1552.83228,15.598,2631.40405,0.840,
1552.92383,14.598,2631.49561,1.840,
1553.01538,15.598,2631.58716,1.840,
1553.10681,15.598,2631.67871,1.840,
1553.19836,14.598,2631.77026,1.840,
1553.28992,15.598,2631.86182,1.840,
1553.38147,15.598,2631.95337,1.840,
1553.47290,14.598,2632.04468,1.840,
1553.56445,15.598,2632.13623,0.840,
1553.65601,15.598,2632.22778,1.840,
1553.74756,15.598,2632.31934,1.840,
1553.83899,14.598,2632.41089,0.840,
1553.93054,14.598,2632.50244,1.840,
1554.02209,15.598,2632.59399,0.840,
1554.11353,15.598,2632.68555,0.840,
1554.20508,15.598,2632.77686,1.840,
1554.29663,14.598,2632.86841,0.840,
1554.38818,14.598,2632.95996,1.840,
1554.47961,14.598,2633.05151,0.840,
1554.57117,15.598,2633.14307,0.840,
1554.66272,15.598,2633.23462,0.840,
1554.75427,14.598,2633.32617,0.840,
1554.84570,15.598,2633.41772,1.840,
1554.93726,14.598,2633.50903,1.840,
1555.02881,14.598,2633.60059,0.840,
1555.12036,15.598,2633.69214,0.840,
1555.21179,15.598,2633.78369,1.840,
1555.30334,15.598,2633.87524,1.840,
1555.39490,14.598,2633.96680,1.840,
1555.48645,15.598,2634.05835,0.840,
1555.57788,15.598,2634.14966,1.840,
1555.66943,14.598,2634.24121,1.840,
1555.76099,15.598,2634.33276,1.840,
1555.85254,15.598,2634.42432,1.840,
1555.94397,15.598,2634.51587,1.840,
1556.03552,15.598,2634.60742,0.840,
1556.12708,15.598,2634.69897,0.840,
1556.21851,15.598,2634.79053,0.840,
1556.31006,15.598,2634.88184,0.840,
1556.40161,15.598,2634.97339,1.840,
1556.49316,15.598,2635.06494,1.840,
1556.58459,15.598,2635.15649,0.840,
1556.67615,15.598,2635.24805,1.840,
1556.76770,15.598,2635.33960,0.840,
1556.85925,14.598,2635.43115,1.840,
1556.95068,15.598,2635.52246,0.840,
1557.04224,15.598,2635.61401,0.840,
1557.13379,15.598,2635.70557,1.840,
1557.22534,14.598,2635.79712,0.840,
1557.31677,15.598,2635.88867,1.840,
1557.40833,15.598,2635.98022,0.840,
1557.49988,15.598,2636.07178,0.840,
1557.59143,15.598,2636.16333,0.840,
1557.68286,15.598,2636.25464,0.840,
1557.77441,15.598,2636.34619,0.840,
1557.86597,15.598,2636.43774,0.840,
1557.95740,15.598,2636.52930,0.840,
1558.04895,15.598,2636.62085,0.840,
1558.14050,15.598,2636.71240,0.840,
1558.23206,15.598,2636.80396,0.840,
1558.32349,15.598,2636.89551,1.840,
1558.41504,15.598,2636.98682,0.840,
1558.50659,15.598,2637.07837,1.840,
1558.59814,15.598,2637.16992,1.840,
1558.68958,15.598,2637.26147,1.840,
1558.78113,14.598,2637.35303,0.840,
1558.87268,15.598,2637.44458,1.840,
1558.96423,15.598,2637.53613,0.840,
1559.05566,15.598,2637.62744,0.840,
1559.14722,15.598,2637.71899,0.840,
1559.23877,15.598,2637.81055,0.840,
1559.33032,15.598,2637.90210,0.840,
1559.42175,15.598,2637.99365,0.840,
1559.51331,15.598,2638.08521,1.840,
1559.60486,15.598,2638.17676,1.840,
1559.69641,15.598,2638.26831,0.840,
1559.78784,15.598,2638.35962,1.840,
1559.87939,15.598,2638.45117,1.840,
1559.97095,15.598,2638.54272,0.840,
1560.06238,15.598,2638.63428,0.840,
1560.15393,15.598,2638.72583,0.840,
1560.24548,15.598,2638.81738,0.840,
1560.33704,15.598,2638.90894,1.840,
1560.42847,16.598,2639.00049,0.840,
1560.52002,15.598,2639.09180,1.840,
1560.61157,14.598,2639.18335,1.840,
1560.70313,15.598,2639.27490,0.840,
1560.79456,15.598,2639.36646,1.840,
1560.88611,15.598,2639.45801,0.840,
1560.97766,15.598,2639.54956,0.840,
1561.06921,15.598,2639.64111,1.840,
1561.16064,15.598,2639.73242,1.840,
1561.25220,15.598,2639.82397,0.840,
1561.34375,15.598,2639.91553,1.840,
1561.43530,15.598,2640.00708,1.840,
1561.52673,16.598,2640.09863,0.840,
1561.61829,16.598,2640.19019,0.840,
1561.70984,16.598,2640.28174,1.840,
1561.80127,15.598,2640.37329,1.840,
1561.89282,17.598,2640.46460,0.840,
1561.98438,16.598,2640.55615,1.840,
1562.07593,15.598,2640.64771,0.840,
1562.16736,16.598,2640.73926,0.840,
1562.25891,16.598,2640.83081,1.840,
1562.35046,15.598,2640.92236,0.840,
1562.44202,16.598,2641.01392,0.840,
1562.53345,15.598,2641.10522,1.840,
1562.62500,15.598,2641.19678,1.840,
1562.71655,15.598,2641.28833,1.840,
1562.80811,15.598,2641.37988,1.840,
1562.89954,15.598,2641.47144,1.840,
1562.99109,15.598,2641.56299,1.840,
1563.08264,15.598,2641.65454,1.840,
1563.17419,15.598,2641.74609,1.840,
1563.26563,14.598,2641.83740,1.840,
1563.35718,15.598,2641.92896,0.840,
1563.44873,15.598,2642.02051,1.840,
1563.54016,15.598,2642.11206,1.840,
1563.63171,15.598,2642.20361,1.840,
1563.72327,15.598,2642.29517,0.840,
1563.81482,15.598,2642.38672,1.840,
1563.90625,15.598,2642.47827,0.840,
1563.99780,15.598,2642.56958,1.840,
1564.08936,16.598,2642.66113,1.840,
1564.18091,16.598,2642.75269,1.840,
1564.27234,16.598,2642.84424,0.840,
1564.36389,16.598,2642.93579,1.840,
1564.45544,16.598,2643.02734,1.840,
1564.54700,16.598,2643.11890,1.840,
1564.63843,16.598,2643.21021,1.840,
1564.72998,16.598,2643.30176,1.840,
1564.82153,16.598,2643.39331,0.840,
1564.91309,15.598,2643.48486,1.840,
1565.00452,16.598,2643.57642,1.840,
1565.09607,15.598,2643.66797,0.840,
1565.18762,15.598,2643.75952,1.840,
1565.27917,15.598,2643.85107,0.840,
1565.37061,15.598,2643.94238,1.840,
1565.46216,15.598,2644.03394,1.840,
1565.55371,15.598,2644.12549,1.840,
1565.64514,15.598,2644.21704,1.840,
1565.73669,15.598,2644.30859,1.840,
1565.82825,15.598,2644.40015,1.840,
1565.91980,15.598,2644.49170,0.840,
1566.01123,15.598,2644.58325,1.840,
1566.10278,15.598,2644.67456,1.840,
1566.19434,15.598,2644.76611,0.840,
1566.28589,15.598,2644.85767,0.840,
1566.37732,15.598,2644.94922,0.840,
1566.46887,15.598,2645.04077,0.840,
1566.56042,15.598,2645.13232,0.840,
1566.65198,15.598,2645.22388,0.840,
1566.74341,15.598,2645.31519,0.840,
1566.83496,16.598,2645.40674,0.840,
1566.92651,15.598,2645.49829,1.840,
1567.01807,16.598,2645.58984,1.840,
1567.10950,15.598,2645.68140,0.840,
1567.20105,15.598,2645.77295,1.840,
1567.29260,15.598,2645.86450,1.840,
1567.38403,15.598,2645.95605,0.840,
1567.47559,15.598,2646.04736,1.840,
1567.56714,15.598,2646.13892,1.840,
1567.65869,15.598,2646.23047,1.840,
1567.75012,15.598,2646.32202,0.840,
1567.84167,15.598,2646.41357,0.840,
1567.93323,15.598,2646.50513,1.840,
1568.02478,15.598,2646.59668,1.840,
1568.11621,15.598,2646.68799,2.840,
1568.20776,15.598,2646.77954,2.840,
1568.29932,15.598,2646.87109,2.840,
1568.39087,15.598,2646.96265,4.840,
1568.48230,15.598,2647.05420,3.840,
1568.57385,15.598,2647.14575,2.840,
1568.66541,15.598,2647.23730,3.840,
1568.75696,15.598,2647.32886,3.840,
1568.84839,15.598,2647.42017,3.840,
1568.93994,15.598,2647.51172,2.840,
1569.03149,15.598,2647.60327,3.840,
1569.12305,15.598,2647.69482,2.840,
1569.21448,15.598,2647.78638,2.840,
1569.30603,15.598,2647.87793,1.840,
1569.39758,15.598,2647.96948,2.840,
1569.48901,15.598,2648.06104,1.840,
1569.58057,15.598,2648.15234,1.840,
1569.67212,15.598,2648.24390,1.840,
1569.76367,15.598,2648.33545,1.840,
1569.85510,15.598,2648.42700,1.840,
1569.94666,15.598,2648.51855,1.840,
1570.03821,15.598,2648.61011,1.840,
1570.12976,15.598,2648.70166,0.840,
1570.22119,15.598,2648.79297,0.840,
1570.31274,15.598,2648.88452,1.840,
1570.40430,15.598,2648.97607,1.840,
1570.49585,15.598,2649.06763,1.840,
1570.58728,15.598,2649.15918,1.840,
1570.67883,15.598,2649.25073,0.840,
1570.77039,15.598,2649.34229,0.840,
1570.86194,15.598,2649.43384,1.840,
1570.95337,15.598,2649.52515,1.840,
1571.04492,16.598,2649.61670,0.840,
1571.13647,16.598,2649.70825,1.840,
1571.22791,15.598,2649.79980,1.840,
1571.31946,15.598,2649.89136,1.840,
1571.41101,15.598,2649.98291,1.840,
1571.50256,15.598,2650.07446,1.840,
1571.59399,15.598,2650.16602,1.840,
1571.68555,16.598,2650.25732,1.840,
1571.77710,15.598,2650.34888,1.840,
1571.86865,15.598,2650.44043,1.840,
1571.96008,15.598,2650.53198,1.840,
1572.05164,15.598,2650.62354,1.840,
1572.14319,16.598,2650.71509,1.840,
1572.23474,16.598,2650.80664,1.840,
1572.32617,15.598,2650.89795,1.840,
1572.41772,15.598,2650.98950,1.840,
1572.50928,15.598,2651.08105,0.840,
1572.60083,15.598,2651.17261,1.840,
1572.69226,16.598,2651.26416,1.840,
1572.78381,15.598,2651.35571,1.840,
1572.87537,15.598,2651.44727,1.840,
1572.96680,15.598,2651.53882,1.840,
1573.05835,16.598,2651.63013,1.840,
1573.14990,15.598,2651.72168,1.840,
1573.24146,16.598,2651.81323,1.840,
1573.33289,15.598,2651.90479,1.840,
1573.42444,15.598,2651.99634,1.840,
1573.51599,16.598,2652.08789,1.840,
1573.60754,16.598,2652.17944,1.840,
1573.69897,15.598,2652.27100,1.840,
1573.79053,15.598,2652.36230,1.840,
1573.88208,16.598,2652.45386,1.840,
1573.97363,16.598,2652.54541,1.840,
1574.06506,15.598,2652.63696,1.840,
1574.15662,16.598,2652.72852,1.840,
1574.24817,15.598,2652.82007,1.840,
1574.33972,15.598,2652.91162,1.840,
1574.43115,15.598,2653.00293,1.840,
1574.52271,16.598,2653.09448,1.840,
1574.61426,15.598,2653.18604,1.840,
1574.70581,16.598,2653.27759,1.840,
1574.79724,16.598,2653.36914,1.840,
1574.88879,16.598,2653.46069,1.840,
1574.98035,15.598,2653.55225,1.840,
1575.07178,16.598,2653.64380,1.840,
1575.16333,16.598,2653.73511,1.840,
1575.25488,16.598,2653.82666,1.840,
1575.34644,15.598,2653.91821,1.840,
1575.43787,16.598,2654.00977,1.840,
1575.52942,16.598,2654.10132,1.840,
1575.62097,16.598,2654.19287,1.840,
1575.71252,16.598,2654.28442,1.840,
1575.80396,16.598,2654.37573,1.840,
1575.89551,15.598,2654.46729,1.840,
1575.98706,16.598,2654.55884,1.840,
1576.07861,16.598,2654.65039,2.840,
1576.17004,16.598,2654.74194,1.840,
1576.26160,16.598,2654.83350,1.840,
1576.35315,16.598,2654.92505,2.840,
1576.44470,16.598,2655.01660,2.840,
1576.53613,17.598,2655.10791,1.840,
1576.62769,16.598,2655.19946,1.840,
1576.71924,16.598,2655.29102,1.840,
1576.81067,16.598,2655.38257,1.840,
1576.90222,16.598,2655.47412,1.840,
1576.99377,16.598,2655.56567,1.840,
1577.08533,16.598,2655.65723,1.840,
1577.17676,16.598,2655.74878,1.840,
1577.26831,16.598,2655.84009,1.840,
1577.35986,16.598,2655.93164,1.840,
1577.45142,15.598,2656.02319,1.840,
1577.54285,16.598,2656.11475,1.840,
1577.63440,16.598,2656.20630,2.840,
1577.72595,15.598,2656.29785,1.840,
1577.81750,16.598,2656.38940,1.840,
1577.90894,16.598,2656.48071,1.840,
1578.00049,16.598,2656.57227,1.840,
1578.09204,16.598,2656.66382,1.840,
1578.18359,16.598,2656.75537,1.840,
1578.27502,16.598,2656.84692,2.840,
1578.36658,16.598,2656.93848,1.840,
1578.45813,16.598,2657.03003,1.840,
1578.54968,16.598,2657.12158,1.840,
1578.64111,16.598,2657.21289,2.840,
1578.73267,16.598,2657.30444,1.840,
1578.82422,16.598,2657.39600,1.840,
1578.91565,16.598,2657.48755,1.840,
1579.00720,16.598,2657.57910,1.840,
1579.09875,16.598,2657.67065,1.840,
1579.19031,16.598,2657.76221,1.840,
1579.28174,16.598,2657.85376,0.840,
1579.37329,16.598,2657.94507,1.840,
1579.46484,16.598,2658.03662,1.840,
1579.55640,16.598,2658.12817,1.840,
1579.64783,16.598,2658.21973,1.840,
1579.73938,16.598,2658.31128,1.840,
1579.83093,16.598,2658.40283,1.840,
1579.92249,16.598,2658.49438,1.840,
1580.01392,16.598,2658.58569,1.840,
1580.10547,16.598,2658.67725,1.840,
1580.19702,16.598,2658.76880,1.840,
1580.28857,16.598,2658.86035,1.840,
1580.38000,16.598,2658.95190,1.840,
1580.47156,16.598,2659.04346,1.840,
1580.56311,16.598,2659.13501,1.840,
1580.65454,16.598,2659.22656,1.840,
1580.74609,16.598,2659.31787,1.840,
1580.83765,16.598,2659.40942,1.840,
1580.92920,16.598,2659.50098,1.840,
1581.02063,17.598,2659.59253,1.840,
1581.11218,17.598,2659.68408,1.840,
1581.20374,17.598,2659.77563,1.840,
1581.29529,17.598,2659.86719,1.840,
1581.38672,17.598,2659.95850,1.840,
1581.47827,17.598,2660.05005,1.840,
1581.56982,18.598,2660.14160,2.840,
1581.66138,17.598,2660.23315,2.840,
1581.75281,17.598,2660.32471,1.840,
1581.84436,17.598,2660.41626,2.840,
1581.93591,17.598,2660.50781,1.840,
1582.02747,17.598,2660.59937,1.840,
1582.11890,17.598,2660.69067,2.840,
1582.21045,17.598,2660.78223,1.840,
1582.30200,18.598,2660.87378,1.840,
1582.39343,17.598,2660.96533,1.840,
1582.48499,17.598,2661.05688,1.840,
1582.57654,17.598,2661.14844,2.840,
1582.66809,17.598,2661.23999,1.840,
1582.75952,17.598,2661.33154,1.840,
1582.85107,17.598,2661.42285,1.840,
1582.94263,17.598,2661.51440,1.840,
1583.03418,17.598,2661.60596,2.840,
1583.12561,17.598,2661.69751,1.840,
1583.21716,16.598,2661.78906,1.840,
1583.30872,16.598,2661.88062,1.840,
1583.40027,17.598,2661.97217,1.840,
1583.49170,16.598,2662.06348,2.840,
1583.58325,16.598,2662.15503,2.840,
1583.67480,16.598,2662.24658,2.840,
1583.76636,16.598,2662.33813,2.840,
1583.85779,17.598,2662.42969,1.840,
1583.94934,16.598,2662.52124,1.840,
1584.04089,16.598,2662.61279,1.840,
1584.13245,17.598,2662.70435,1.840,
1584.22388,16.598,2662.79565,1.840,
1584.31543,17.598,2662.88721,1.840,
1584.40698,17.598,2662.97876,1.840,
1584.49841,16.598,2663.07031,1.840,
1584.58997,17.598,2663.16187,1.840,
1584.68152,16.598,2663.25342,1.840,
1584.77307,16.598,2663.34497,2.840,
1584.86450,16.598,2663.43652,1.840,
1584.95605,17.598,2663.52783,2.840,
1585.04761,16.598,2663.61938,2.840,
1585.13916,16.598,2663.71094,1.840,
1585.23059,17.598,2663.80249,1.840,
1585.32214,17.598,2663.89404,1.840,
1585.41370,16.598,2663.98560,1.840,
1585.50525,17.598,2664.07715,2.840,
1585.59668,17.598,2664.16846,2.840,
1585.68823,17.598,2664.26001,2.840,
1585.77979,17.598,2664.35156,1.840,
1585.87134,17.598,2664.44312,2.840,
1585.96277,17.598,2664.53467,2.840,
1586.05432,16.598,2664.62622,1.840,
1586.14587,17.598,2664.71777,1.840,
1586.23730,16.598,2664.80933,1.840,
1586.32886,16.598,2664.90063,1.840,
1586.42041,16.598,2664.99219,1.840,
1586.51196,17.598,2665.08374,1.840,
1586.60339,16.598,2665.17529,2.840,
1586.69495,16.598,2665.26685,1.840,
1586.78650,18.598,2665.35840,1.840,
1586.87805,17.598,2665.44995,2.840,
1586.96948,16.598,2665.54126,1.840,
1587.06104,17.598,2665.63281,2.840,
1587.15259,17.598,2665.72437,2.840,
1587.24414,16.598,2665.81592,1.840,
1587.33557,17.598,2665.90747,1.840,
1587.42712,17.598,2665.99902,3.840,
1587.51868,17.598,2666.09058,2.840,
1587.61023,17.598,2666.18213,1.840,
1587.70166,17.598,2666.27344,2.840,
1587.79321,17.598,2666.36499,2.840,
1587.88477,16.598,2666.45654,1.840,
1587.97632,17.598,2666.54810,1.840,
1588.06775,17.598,2666.63965,2.840,
1588.15930,16.598,2666.73120,1.840,
1588.25085,17.598,2666.82275,1.840,
1588.34229,17.598,2666.91431,1.840,
1588.43384,17.598,2667.00562,1.840,
1588.52539,17.598,2667.09717,1.840,
1588.61694,17.598,2667.18872,1.840,
1588.70837,16.598,2667.28027,1.840,
1588.79993,16.598,2667.37183,1.840,
1588.89148,17.598,2667.46338,2.840,
1588.98303,16.598,2667.55493,1.840,
1589.07446,17.598,2667.64624,1.840,
1589.16602,17.598,2667.73779,1.840,
1589.25757,17.598,2667.82935,1.840,
1589.34912,17.598,2667.92090,1.840,
1589.44055,17.598,2668.01245,1.840,
1589.53210,17.598,2668.10400,1.840,
1589.62366,17.598,2668.19556,2.840,
1589.71521,17.598,2668.28711,1.840,
1589.80664,17.598,2668.37842,1.840,
1589.89819,17.598,2668.46997,1.840,
1589.98975,17.598,2668.56152,2.840,
1590.08118,17.598,2668.65308,2.840,
1590.17273,17.598,2668.74463,2.840,
1590.26428,17.598,2668.83618,1.840,
1590.35583,17.598,2668.92773,2.840,
1590.44727,17.598,2669.01929,1.840,
1590.53882,17.598,2669.11060,2.840,
1590.63037,17.598,2669.20215,2.840,
1590.72192,17.598,2669.29370,2.840,
1590.81335,17.598,2669.38525,2.840,
1590.90491,17.598,2669.47681,2.840,
1590.99646,17.598,2669.56836,2.840,
1591.08801,17.598,2669.65991,2.840,
1591.17944,18.598,2669.75122,1.840,
1591.27100,17.598,2669.84277,2.840,
1591.36255,17.598,2669.93433,1.840,
1591.45410,18.598,2670.02588,2.840,
1591.54553,17.598,2670.11743,1.840,
1591.63708,18.598,2670.20898,2.840,
1591.72864,17.598,2670.30054,2.840,
1591.82007,17.598,2670.39209,2.840,
1591.91162,17.598,2670.48340,2.840,
1592.00317,17.598,2670.57495,2.840,
1592.09473,17.598,2670.66650,2.840,
1592.18616,17.598,2670.75806,2.840,
1592.27771,17.598,2670.84961,2.840,
1592.36926,17.598,2670.94116,2.840,
1592.46082,17.598,2671.03271,2.840,
1592.55225,17.598,2671.12427,2.840,
1592.64380,18.598,2671.21558,1.840,
1592.73535,18.598,2671.30713,1.840,
1592.82690,18.598,2671.39868,2.840,
1592.91833,18.598,2671.49023,2.840,
1593.00989,17.598,2671.58179,1.840,
1593.10144,17.598,2671.67334,2.840,
1593.19299,18.598,2671.76489,3.840,
1593.28442,17.598,2671.85620,2.840,
1593.37598,17.598,2671.94775,2.840,
1593.46753,17.598,2672.03931,2.840,
1593.55908,18.598,2672.13086,2.840,
1593.65051,17.598,2672.22241,2.840,
1593.74207,18.598,2672.31396,2.840,
1593.83362,18.598,2672.40552,2.840,
1593.92505,17.598,2672.49707,2.840,
1594.01660,17.598,2672.58838,2.840,
1594.10815,18.598,2672.67993,1.840,
1594.19971,18.598,2672.77148,2.840,
1594.29114,18.598,2672.86304,1.840,
1594.38269,18.598,2672.95459,2.840,
1594.47424,18.598,2673.04614,2.840,
1594.56580,17.598,2673.13770,2.840,
1594.65723,18.598,2673.22900,2.840,
1594.74878,18.598,2673.32056,2.840,
1594.84033,17.598,2673.41211,2.840,
1594.93188,17.598,2673.50366,2.840,
1595.02332,17.598,2673.59521,1.840,
1595.11487,17.598,2673.68677,2.840,
1595.20642,17.598,2673.77832,1.840,
1595.29797,17.598,2673.86987,2.840,
1595.38940,18.598,2673.96118,2.840,
1595.48096,17.598,2674.05273,2.840,
1595.57251,18.598,2674.14429,2.840,
1595.66394,18.598,2674.23584,2.840,
1595.75549,17.598,2674.32739,2.840,
1595.84705,17.598,2674.41895,2.840,
1595.93860,17.598,2674.51050,2.840,
1596.03003,17.598,2674.60205,2.840,
1596.12158,17.598,2674.69336,2.840,
1596.21313,17.598,2674.78491,2.840,
1596.30469,17.598,2674.87646,2.840,
1596.39612,18.598,2674.96802,3.840,
1596.48767,17.598,2675.05957,2.840,
1596.57922,17.598,2675.15112,2.840,
1596.67078,18.598,2675.24268,2.840,
1596.76221,18.598,2675.33398,2.840,
1596.85376,18.598,2675.42554,2.840,
1596.94531,18.598,2675.51709,2.840,
1597.03687,18.598,2675.60864,2.840,
1597.12830,18.598,2675.70020,2.840,
1597.21985,19.598,2675.79175,2.840,
1597.31140,18.598,2675.88330,2.840,
1597.40295,18.598,2675.97485,1.840,
1597.49438,18.598,2676.06616,2.840,
1597.58594,18.598,2676.15771,2.840,
1597.67749,18.598,2676.24927,2.840,
1597.76892,18.598,2676.34082,2.840,
1597.86047,18.598,2676.43237,2.840,
1597.95203,18.598,2676.52393,2.840,
1598.04358,18.598,2676.61548,2.840,
1598.13501,18.598,2676.70703,2.840,
1598.22656,18.598,2676.79834,2.840,
1598.31812,18.598,2676.88989,2.840,
1598.40967,18.598,2676.98145,2.840,
1598.50110,18.598,2677.07300,2.840,
1598.59265,17.598,2677.16455,2.840,
1598.68420,18.598,2677.25610,2.840,
1598.77576,18.598,2677.34766,2.840,
1598.86719,18.598,2677.43896,2.840,
1598.95874,18.598,2677.53052,2.840,
1599.05029,17.598,2677.62207,2.840,
1599.14185,18.598,2677.71362,3.840,
1599.23328,17.598,2677.80518,2.840,
1599.32483,17.598,2677.89673,2.840,
1599.41638,17.598,2677.98828,3.840,
1599.50781,16.598,2678.07983,2.840,
1599.59937,17.598,2678.17114,2.840,
1599.69092,17.598,2678.26270,2.840,
1599.78247,16.598,2678.35425,2.840,
1599.87390,17.598,2678.44580,2.840,
1599.96545,17.598,2678.53735,3.840,
1600.05701,17.598,2678.62891,2.840,
1600.14856,17.598,2678.72046,2.840,
1600.23999,17.598,2678.81177,2.840,
1600.33154,17.598,2678.90332,2.840,
1600.42310,17.598,2678.99487,2.840,
1600.51465,18.598,2679.08643,2.840,
1600.60608,17.598,2679.17798,3.840,
1600.69763,18.598,2679.26953,2.840,
1600.78918,17.598,2679.36108,2.840,
1600.88074,18.598,2679.45264,2.840,
1600.97217,18.598,2679.54395,2.840,
1601.06372,18.598,2679.63550,2.840,
1601.15527,18.598,2679.72705,2.840,
1601.24670,18.598,2679.81860,2.840,
1601.33826,18.598,2679.91016,2.840,
1601.42981,19.598,2680.00171,2.840,
1601.52136,18.598,2680.09326,2.840,
1601.61279,18.598,2680.18481,2.840,
1601.70435,18.598,2680.27612,2.840,
1601.79590,18.598,2680.36768,2.840,
1601.88745,18.598,2680.45923,2.840,
1601.97888,18.598,2680.55078,2.840,
1602.07043,18.598,2680.64233,2.840,
1602.16199,18.598,2680.73389,2.840,
1602.25354,18.598,2680.82544,2.840,
1602.34497,17.598,2680.91675,2.840,
1602.43652,18.598,2681.00830,2.840,
1602.52808,18.598,2681.09985,2.840,
1602.61963,18.598,2681.19141,2.840,
1602.71106,18.598,2681.28296,2.840,
1602.80261,18.598,2681.37451,3.840,
1602.89417,18.598,2681.46606,2.840,
1602.98572,18.598,2681.55762,3.840,
1603.07715,18.598,2681.64893,3.840,
1603.16870,18.598,2681.74048,2.840,
1603.26025,18.598,2681.83203,3.840,
1603.35168,18.598,2681.92358,3.840,
1603.44324,18.598,2682.01514,3.840,
1603.53479,18.598,2682.10669,3.840,
1603.62634,18.598,2682.19824,3.840,
1603.71777,18.598,2682.28979,3.840,
1603.80933,18.598,2682.38110,2.840,
1603.90088,18.598,2682.47266,2.840,
1603.99243,18.598,2682.56421,3.840,
1604.08386,18.598,2682.65576,2.840,
1604.17542,18.598,2682.74731,2.840,
1604.26697,18.598,2682.83887,3.840,
1604.35852,18.598,2682.93042,2.840,
1604.44995,18.598,2683.02173,2.840,
1604.54150,18.598,2683.11328,2.840,
1604.63306,18.598,2683.20483,2.840,
1604.72461,18.598,2683.29639,2.840,
1604.81604,18.598,2683.38794,2.840,
1604.90759,18.598,2683.47949,2.840,
1604.99915,18.598,2683.57104,3.840,
1605.09058,18.598,2683.66260,2.840,
1605.18213,18.598,2683.75391,2.840,
1605.27368,18.598,2683.84546,2.840,
1605.36523,18.598,2683.93701,2.840,
1605.45667,18.598,2684.02856,3.840,
1605.54822,18.598,2684.12012,2.840,
1605.63977,18.598,2684.21167,3.840,
1605.73132,18.598,2684.30322,2.840,
1605.82275,18.598,2684.39453,2.840,
1605.91431,18.598,2684.48608,3.840,
1606.00586,18.598,2684.57764,2.840,
1606.09741,18.598,2684.66919,2.840,
1606.18884,18.598,2684.76074,3.840,
1606.28040,18.598,2684.85229,2.840,
1606.37195,18.598,2684.94385,2.840,
1606.46350,18.598,2685.03540,3.840,
1606.55493,18.598,2685.12671,3.840,
1606.64648,18.598,2685.21826,3.840,
1606.73804,18.598,2685.30981,2.840,
1606.82959,19.598,2685.40137,3.840,
1606.92102,18.598,2685.49292,3.840,
1607.01257,18.598,2685.58447,3.840,
1607.10413,18.598,2685.67603,3.840,
1607.19556,18.598,2685.76758,3.840,
1607.28711,19.598,2685.85889,2.840,
1607.37866,19.598,2685.95044,3.840,
1607.47021,18.598,2686.04199,3.840,
1607.56165,18.598,2686.13354,2.840,
1607.65320,19.598,2686.22510,3.840,
1607.74475,18.598,2686.31665,3.840,
1607.83630,18.598,2686.40820,2.840,
1607.92773,18.598,2686.49951,3.840,
1608.01929,18.598,2686.59106,3.840,
1608.11084,18.598,2686.68262,3.840,
1608.20239,18.598,2686.77417,2.840,
1608.29382,18.598,2686.86572,2.840,
1608.38538,18.598,2686.95728,3.840,
1608.47693,18.598,2687.04883,2.840,
1608.56848,19.598,2687.14038,3.840,
1608.65991,19.598,2687.23169,3.840,
1608.75146,19.598,2687.32324,2.840,
1608.84302,19.598,2687.41479,2.840,
1608.93445,19.598,2687.50635,2.840,
1609.02600,19.598,2687.59790,2.840,
1609.11755,19.598,2687.68945,2.840,
1609.20911,19.598,2687.78101,2.840,
1609.30054,18.598,2687.87256,2.840,
1609.39209,19.598,2687.96387,3.840,
1609.48364,19.598,2688.05542,2.840,
1609.57520,19.598,2688.14697,2.840,
1609.66663,18.598,2688.23853,2.840,
1609.75818,18.598,2688.33008,2.840,
1609.84973,18.598,2688.42163,2.840,
1609.94128,18.598,2688.51318,2.840,
1610.03271,18.598,2688.60449,2.840,
1610.12427,19.598,2688.69604,2.840,
1610.21582,19.598,2688.78760,2.840,
1610.30737,19.598,2688.87915,2.840,
1610.39880,19.598,2688.97070,2.840,
1610.49036,18.598,2689.06226,2.840,
1610.58191,19.598,2689.15381,2.840,
1610.67334,19.598,2689.24536,2.840,
1610.76489,19.598,2689.33667,2.840,
1610.85645,19.598,2689.42822,3.840,
1610.94800,19.598,2689.51978,2.840,
1611.03943,19.598,2689.61133,3.840,
1611.13098,18.598,2689.70288,2.840,
1611.22253,19.598,2689.79443,2.840,
1611.31409,19.598,2689.88599,2.840,
1611.40552,18.598,2689.97754,3.840,
1611.49707,18.598,2690.06885,2.840,
1611.58862,19.598,2690.16040,3.840,
1611.68018,19.598,2690.25195,3.840,
1611.77161,18.598,2690.34351,2.840,
1611.86316,19.598,2690.43506,1.840,
1611.95471,18.598,2690.52661,2.840,
1612.04626,18.598,2690.61816,2.840,
1612.13770,19.598,2690.70947,2.840,
1612.22925,19.598,2690.80103,2.840,
1612.32080,19.598,2690.89258,2.840,
1612.41235,18.598,2690.98413,2.840,
1612.50378,18.598,2691.07568,2.840,
1612.59534,19.598,2691.16724,2.840,
1612.68689,18.598,2691.25879,2.840,
1612.77832,18.598,2691.35034,2.840,
1612.86987,19.598,2691.44165,2.840,
1612.96143,18.598,2691.53320,2.840,
1613.05298,18.598,2691.62476,2.840,
1613.14441,19.598,2691.71631,2.840,
1613.23596,19.598,2691.80786,1.840,
1613.32751,18.598,2691.89941,2.840,
1613.41907,19.598,2691.99097,2.840,
1613.51050,19.598,2692.08228,2.840,
1613.60205,18.598,2692.17383,2.840,
1613.69360,18.598,2692.26538,2.840,
1613.78516,19.598,2692.35693,3.840,
1613.87659,19.598,2692.44849,2.840,
1613.96814,19.598,2692.54004,2.840,
1614.05969,19.598,2692.63159,2.840,
1614.15125,18.598,2692.72314,2.840,
1614.24268,19.598,2692.81445,2.840,
1614.33423,19.598,2692.90601,3.840,
1614.42578,19.598,2692.99756,3.840,
1614.51721,18.598,2693.08911,3.840,
1614.60876,19.598,2693.18066,2.840,
1614.70032,19.598,2693.27222,2.840,
1614.79187,19.598,2693.36377,2.840,
1614.88330,19.598,2693.45532,2.840,
1614.97485,19.598,2693.54663,3.840,
1615.06641,19.598,2693.63818,2.840,
1615.15796,19.598,2693.72974,2.840,
1615.24939,19.598,2693.82129,2.840,
1615.34094,19.598,2693.91284,2.840,
1615.43250,19.598,2694.00439,2.840,
1615.52405,19.598,2694.09595,2.840,
1615.61548,19.598,2694.18726,3.840,
1615.70703,18.598,2694.27881,3.840,
1615.79858,18.598,2694.37036,3.840,
1615.89014,18.598,2694.46191,3.840,
1615.98157,18.598,2694.55347,3.840,
1616.07312,19.598,2694.64502,3.840,
1616.16467,18.598,2694.73657,2.840,
1616.25623,19.598,2694.82813,2.840,
1616.34766,19.598,2694.91943,2.840,
1616.43921,19.598,2695.01099,2.840,
1616.53076,19.598,2695.10254,3.840,
1616.62219,19.598,2695.19409,2.840,
1616.71375,19.598,2695.28564,3.840,
1616.80530,19.598,2695.37720,2.840,
1616.89685,19.598,2695.46875,3.840,
1616.98828,18.598,2695.56030,2.840,
1617.07983,18.598,2695.65161,3.840,
1617.17139,19.598,2695.74316,3.840,
1617.26294,17.598,2695.83472,3.840,
1617.35437,18.598,2695.92627,3.840,
1617.44592,18.598,2696.01782,3.840,
1617.53748,19.598,2696.10938,3.840,
1617.62903,18.598,2696.20093,2.840,
1617.72046,19.598,2696.29224,2.840,
1617.81201,19.598,2696.38379,3.840,
1617.90356,18.598,2696.47534,2.840,
1617.99512,19.598,2696.56689,2.840,
1618.08655,19.598,2696.65845,2.840,
1618.17810,19.598,2696.75000,3.840,
1618.26965,19.598,2696.84155,2.840,
1618.36108,19.598,2696.93311,2.840,
1618.45264,19.598,2697.02441,2.840,
1618.54419,18.598,2697.11597,2.840,
1618.63574,19.598,2697.20752,2.840,
1618.72717,19.598,2697.29907,2.840,
1618.81873,19.598,2697.39063,2.840,
1618.91028,19.598,2697.48218,2.840,
1619.00183,19.598,2697.57373,2.840,
1619.09326,19.598,2697.66504,2.840,
1619.18481,19.598,2697.75659,2.840,
1619.27637,19.598,2697.84814,3.840,
1619.36792,19.598,2697.93970,2.840,
1619.45935,19.598,2698.03125,2.840,
1619.55090,19.598,2698.12280,2.840,
1619.64246,19.598,2698.21436,3.840,
1619.73401,19.598,2698.30591,3.840,
1619.82544,19.598,2698.39722,2.840,
1619.91699,19.598,2698.48877,3.840,
1620.00854,19.598,2698.58032,3.840,
1620.09998,19.598,2698.67188,2.840,
1620.19153,19.598,2698.76343,3.840,
1620.28308,19.598,2698.85498,2.840,
1620.37463,19.598,2698.94653,3.840,
1620.46606,20.598,2699.03809,2.840,
1620.55762,19.598,2699.12939,3.840,
1620.64917,19.598,2699.22095,2.840,
1620.74072,19.598,2699.31250,2.840,
1620.83215,19.598,2699.40405,3.840,
1620.92371,19.598,2699.49561,3.840,
1621.01526,19.598,2699.58716,3.840,
1621.10681,19.598,2699.67871,3.840,
1621.19824,19.598,2699.77002,3.840,
1621.28979,18.598,2699.86157,3.840,
1621.38135,19.598,2699.95313,2.840,
1621.47290,19.598,2700.04468,3.840,
1621.56433,19.598,2700.13623,3.840,
1621.65588,19.598,2700.22778,3.840,
1621.74744,19.598,2700.31934,3.840,
1621.83899,19.598,2700.41089,3.840,
1621.93042,19.598,2700.50220,2.840,
1622.02197,19.598,2700.59375,2.840,
1622.11353,19.598,2700.68530,3.840,
1622.20496,19.598,2700.77686,2.840,
1622.29651,19.598,2700.86841,2.840,
1622.38806,19.598,2700.95996,2.840,
1622.47961,19.598,2701.05151,2.840,
1622.57104,19.598,2701.14307,3.840,
1622.66260,19.598,2701.23438,2.840,
1622.75415,19.598,2701.32593,2.840,
1622.84570,19.598,2701.41748,2.840,
1622.93713,20.598,2701.50903,2.840,
1623.02869,19.598,2701.60059,2.840,
1623.12024,19.598,2701.69214,2.840,
1623.21179,19.598,2701.78369,2.840,
1623.30322,19.598,2701.87500,2.840,
1623.39478,20.598,2701.96655,2.840,
1623.48633,19.598,2702.05811,2.840,
1623.57788,19.598,2702.14966,2.840,
1623.66931,19.598,2702.24121,2.840,
1623.76086,19.598,2702.33276,2.840,
1623.85242,19.598,2702.42432,2.840,
1623.94385,19.598,2702.51587,3.840,
1624.03540,19.598,2702.60718,3.840,
1624.12695,19.598,2702.69873,2.840,
1624.21851,19.598,2702.79028,3.840,
1624.30994,19.598,2702.88184,3.840,
1624.40149,20.598,2702.97339,2.840,
1624.49304,19.598,2703.06494,3.840,
1624.58459,19.598,2703.15649,3.840,
1624.67603,19.598,2703.24780,3.840,
1624.76758,20.598,2703.33936,3.840,
1624.85913,20.598,2703.43091,3.840,
1624.95068,19.598,2703.52246,2.840,
1625.04211,19.598,2703.61401,2.840,
1625.13367,20.598,2703.70557,2.840,
1625.22522,19.598,2703.79712,3.840,
1625.31677,20.598,2703.88867,3.840,
1625.40820,19.598,2703.97998,2.840,
1625.49976,19.598,2704.07153,3.840,
1625.59131,20.598,2704.16309,2.840,
1625.68286,19.598,2704.25464,3.840,
1625.77429,19.598,2704.34619,3.840,
1625.86584,19.598,2704.43774,3.840,
1625.95740,19.598,2704.52930,2.840,
1626.04883,19.598,2704.62085,3.840,
1626.14038,19.598,2704.71216,3.840,
1626.23193,19.598,2704.80371,2.840,
1626.32349,20.598,2704.89526,3.840,
1626.41492,20.598,2704.98682,3.840,
1626.50647,19.598,2705.07837,3.840,
1626.59802,19.598,2705.16992,3.840,
1626.68958,20.598,2705.26147,2.840,
1626.78101,19.598,2705.35278,3.840,
1626.87256,19.598,2705.44434,3.840,
1626.96411,19.598,2705.53589,3.840,
1627.05566,19.598,2705.62744,3.840,
1627.14709,19.598,2705.71899,2.840,
1627.23865,19.598,2705.81055,3.840,
1627.33020,19.598,2705.90210,3.840,
1627.42175,19.598,2705.99365,3.840,
1627.51318,19.598,2706.08496,3.840,
1627.60474,19.598,2706.17651,2.840,
1627.69629,20.598,2706.26807,3.840,
1627.78772,20.598,2706.35962,3.840,
1627.87927,19.598,2706.45117,3.840,
1627.97083,19.598,2706.54272,3.840,
1628.06238,20.598,2706.63428,3.840,
1628.15381,19.598,2706.72583,3.840,
1628.24536,19.598,2706.81714,3.840,
1628.33691,19.598,2706.90869,3.840,
1628.42847,19.598,2707.00024,3.840,
1628.51990,20.598,2707.09180,4.840,
1628.61145,19.598,2707.18335,3.840,
1628.70300,19.598,2707.27490,3.840,
1628.79456,20.598,2707.36646,3.840,
1628.88599,19.598,2707.45776,3.840,
1628.97754,19.598,2707.54932,3.840,
1629.06909,19.598,2707.64087,3.840,
1629.16064,20.598,2707.73242,3.840,
1629.25208,20.598,2707.82397,3.840,
1629.34363,19.598,2707.91553,3.840,
1629.43518,20.598,2708.00708,3.840,
1629.52661,20.598,2708.09863,3.840,
1629.61816,19.598,2708.18994,3.840,
1629.70972,20.598,2708.28149,3.840,
1629.80127,19.598,2708.37305,3.840,
1629.89270,19.598,2708.46460,3.840,
1629.98425,20.598,2708.55615,3.840,
1630.07581,20.598,2708.64771,3.840,
1630.16736,20.598,2708.73926,3.840,
1630.25879,19.598,2708.83081,3.840,
1630.35034,19.598,2708.92212,3.840,
1630.44189,19.598,2709.01367,3.840,
1630.53345,19.598,2709.10522,3.840,
1630.62488,20.598,2709.19678,3.840,
1630.71643,20.598,2709.28833,3.840,
1630.80798,19.598,2709.37988,3.840,
1630.89954,20.598,2709.47144,2.840,
1630.99097,20.598,2709.56274,3.840,
1631.08252,19.598,2709.65430,3.840,
1631.17407,19.598,2709.74585,3.840,
1631.26563,20.598,2709.83740,3.840,
1631.35706,20.598,2709.92896,3.840,
1631.44861,20.598,2710.02051,3.840,
1631.54016,20.598,2710.11206,2.840,
1631.63159,20.598,2710.20361,3.840,
1631.72314,19.598,2710.29492,3.840,
1631.81470,20.598,2710.38647,3.840,
1631.90625,20.598,2710.47803,3.840,
1631.99768,20.598,2710.56958,3.840,
1632.08923,20.598,2710.66113,3.840,
1632.18079,20.598,2710.75269,3.840,
1632.27234,19.598,2710.84424,3.840,
1632.36377,20.598,2710.93555,3.840,
1632.45532,19.598,2711.02710,3.840,
1632.54688,19.598,2711.11865,3.840,
1632.63843,19.598,2711.21021,3.840,
1632.72986,19.598,2711.30176,3.840,
1632.82141,20.598,2711.39331,4.840,
1632.91296,19.598,2711.48486,3.840,
1633.00452,20.598,2711.57642,3.840,
1633.09595,19.598,2711.66772,3.840,
1633.18750,19.598,2711.75928,3.840,
1633.27905,19.598,2711.85083,3.840,
1633.37048,19.598,2711.94238,3.840,
1633.46204,20.598,2712.03394,3.840,
1633.55359,20.598,2712.12549,3.840,
1633.64514,21.598,2712.21704,3.840,
1633.73657,20.598,2712.30859,3.840,
1633.82813,20.598,2712.39990,3.840,
1633.91968,20.598,2712.49146,3.840,
1634.01123,20.598,2712.58301,2.840,
1634.10266,20.598,2712.67456,3.840,
1634.19421,20.598,2712.76611,3.840,
1634.28577,20.598,2712.85767,3.840,
1634.37732,20.598,2712.94922,3.840,
1634.46875,20.598,2713.04053,3.840,
1634.56030,20.598,2713.13208,3.840,
1634.65186,20.598,2713.22363,3.840,
1634.74341,19.598,2713.31519,3.840,
1634.83484,20.598,2713.40674,3.840,
1634.92639,20.598,2713.49829,3.840,
1635.01794,20.598,2713.58984,3.840,
1635.10938,21.598,2713.68140,3.840,
1635.20093,21.598,2713.77271,3.840,
1635.29248,21.598,2713.86426,3.840,
1635.38403,20.598,2713.95581,3.840,
1635.47546,21.598,2714.04736,2.840,
1635.56702,21.598,2714.13892,3.840,
1635.65857,20.598,2714.23047,3.840,
1635.75012,20.598,2714.32202,3.840,
1635.84155,20.598,2714.41357,3.840,
1635.93311,20.598,2714.50488,3.840,
1636.02466,20.598,2714.59644,3.840,
1636.11621,20.598,2714.68799,3.840,
1636.20764,20.598,2714.77954,3.840,
1636.29919,20.598,2714.87109,3.840,
1636.39075,20.598,2714.96265,3.840,
1636.48230,21.598,2715.05420,3.840,
1636.57373,20.598,2715.14551,3.840,
1636.66528,20.598,2715.23706,3.840,
1636.75684,20.598,2715.32861,3.840,
1636.84839,20.598,2715.42017,3.840,
1636.93982,20.598,2715.51172,3.840,
1637.03137,20.598,2715.60327,3.840,
1637.12292,20.598,2715.69482,3.840,
1637.21436,20.598,2715.78638,4.840,
1637.30591,20.598,2715.87769,3.840,
1637.39746,20.598,2715.96924,3.840,
1637.48901,20.598,2716.06079,3.840,
1637.58044,20.598,2716.15234,3.840,
1637.67200,21.598,2716.24390,3.840,
1637.76355,21.598,2716.33545,3.840,
1637.85510,20.598,2716.42700,3.840,
1637.94653,20.598,2716.51831,3.840,
1638.03809,21.598,2716.60986,3.840,
1638.12964,20.598,2716.70142,3.840,
1638.22119,21.598,2716.79297,3.840,
1638.31262,21.598,2716.88452,3.840,
1638.40417,21.598,2716.97607,3.840,
1638.49573,21.598,2717.06763,3.840,
1638.58728,21.598,2717.15918,3.840,
1638.67871,20.598,2717.25049,4.840,
1638.77026,21.598,2717.34204,3.840,
1638.86182,21.598,2717.43359,3.840,
1638.95325,20.598,2717.52515,3.840,
1639.04480,20.598,2717.61670,3.840,
1639.13635,21.598,2717.70825,3.840,
1639.22791,21.598,2717.79980,3.840,
1639.31934,21.598,2717.89136,3.840,
1639.41089,21.598,2717.98267,3.840,
1639.50244,21.598,2718.07422,3.840,
1639.59399,21.598,2718.16577,3.840,
1639.68542,21.598,2718.25732,3.840,
1639.77698,21.598,2718.34888,3.840,
1639.86853,21.598,2718.44043,2.840,
1639.96008,20.598,2718.53198,3.840,
1640.05151,20.598,2718.62329,3.840,
1640.14307,21.598,2718.71484,3.840,
1640.23462,21.598,2718.80640,3.840,
1640.32617,20.598,2718.89795,3.840,
1640.41760,21.598,2718.98950,3.840,
1640.50916,21.598,2719.08105,3.840,
1640.60071,20.598,2719.17261,2.840,
1640.69226,21.598,2719.26416,3.840,
1640.78369,20.598,2719.35547,3.840,
1640.87524,20.598,2719.44702,3.840,
1640.96680,21.598,2719.53857,3.840,
1641.05823,20.598,2719.63013,2.840,
1641.14978,20.598,2719.72168,3.840,
1641.24133,21.598,2719.81323,3.840,
1641.33289,21.598,2719.90479,3.840,
1641.42432,21.598,2719.99634,3.840,
1641.51587,21.598,2720.08765,3.840,
1641.60742,21.598,2720.17920,4.840,
1641.69897,21.598,2720.27075,3.840,
1641.79041,21.598,2720.36230,3.840,
1641.88196,21.598,2720.45386,3.840,
1641.97351,21.598,2720.54541,3.840,
1642.06506,21.598,2720.63696,3.840,
1642.15649,21.598,2720.72827,3.840,
1642.24805,21.598,2720.81982,3.840,
1642.33960,21.598,2720.91138,3.840,
1642.43115,21.598,2721.00293,3.840,
1642.52258,21.598,2721.09448,2.840,
1642.61414,21.598,2721.18604,3.840,
1642.70569,21.598,2721.27759,2.840,
1642.79712,21.598,2721.36914,1.840,
1642.88867,21.598,2721.46045,1.840,
1642.98022,21.598,2721.55200,1.840,
1643.07178,21.598,2721.64355,2.840,
1643.16321,21.598,2721.73511,1.840,
1643.25476,21.598,2721.82666,2.840,
1643.34631,21.598,2721.91821,2.840,
1643.43787,21.598,2722.00977,2.840,
1643.52930,21.598,2722.10107,2.840,
1643.62085,21.598,2722.19263,2.840,
1643.71240,21.598,2722.28418,2.840,
1643.80396,21.598,2722.37573,2.840,
1643.89539,21.598,2722.46729,3.840,
1643.98694,21.598,2722.55884,3.840,
1644.07849,21.598,2722.65039,3.840,
1644.17004,21.598,2722.74194,3.840,
1644.26147,21.598,2722.83325,3.840,
1644.35303,20.598,2722.92480,3.840,
1644.44458,21.598,2723.01636,3.840,
1644.53601,20.598,2723.10791,4.840,
1644.62756,21.598,2723.19946,3.840,
1644.71912,21.598,2723.29102,3.840,
1644.81067,20.598,2723.38257,3.840,
1644.90210,21.598,2723.47412,4.840,
1644.99365,20.598,2723.56543,3.840,
1645.08521,21.598,2723.65698,3.840,
1645.17676,21.598,2723.74854,3.840,
1645.26819,21.598,2723.84009,3.840,
1645.35974,21.598,2723.93164,2.840,
1645.45129,21.598,2724.02319,2.840,
1645.54285,21.598,2724.11475,2.840,
1645.63428,21.598,2724.20605,2.840,
1645.72583,20.598,2724.29761,2.840,
1645.81738,21.598,2724.38916,2.840,
1645.90894,21.598,2724.48071,3.840,
1646.00037,21.598,2724.57227,3.840,
1646.09192,21.598,2724.66382,3.840,
1646.18347,21.598,2724.75537,3.840,
1646.27502,21.598,2724.84692,2.840,
1646.36646,21.598,2724.93823,3.840,
1646.45801,21.598,2725.02979,3.840,
1646.54956,21.598,2725.12134,3.840,
1646.64099,21.598,2725.21289,3.840,
1646.73254,21.598,2725.30444,3.840,
1646.82410,22.598,2725.39600,3.840,
1646.91565,21.598,2725.48755,3.840,
1647.00708,21.598,2725.57910,3.840,
1647.09863,21.598,2725.67041,3.840,
1647.19019,21.598,2725.76196,4.840,
1647.28174,21.598,2725.85352,3.840,
1647.37317,21.598,2725.94507,3.840,
1647.46472,21.598,2726.03662,4.840,
1647.55627,21.598,2726.12817,4.840,
1647.64783,20.598,2726.21973,4.840,
1647.73926,21.598,2726.31104,4.840,
1647.83081,21.598,2726.40259,4.840,
1647.92236,20.598,2726.49414,3.840,
1648.01392,21.598,2726.58569,3.840,
1648.10535,21.598,2726.67725,4.840,
1648.19690,21.598,2726.76880,3.840,
1648.28845,21.598,2726.86035,3.840,
1648.37988,22.598,2726.95190,3.840,
1648.47144,21.598,2727.04321,3.840,
1648.56299,21.598,2727.13477,3.840,
1648.65454,21.598,2727.22632,3.840,
1648.74597,22.598,2727.31787,3.840,
1648.83752,21.598,2727.40942,4.840,
1648.92908,21.598,2727.50098,4.840,
1649.02063,21.598,2727.59253,4.840,
1649.11206,21.598,2727.68408,4.840,
1649.20361,21.598,2727.77539,4.840,
1649.29517,21.598,2727.86694,3.840,
1649.38672,21.598,2727.95850,4.840,
1649.47815,21.598,2728.05005,4.840,
1649.56970,21.598,2728.14160,4.840,
1649.66125,21.598,2728.23315,3.840,
1649.75281,21.598,2728.32471,4.840,
1649.84424,21.598,2728.41602,3.840,
1649.93579,21.598,2728.50757,4.840,
1650.02734,21.598,2728.59912,4.840,
1650.11890,21.598,2728.69067,4.840,
1650.21033,21.598,2728.78223,3.840,
1650.30188,21.598,2728.87378,4.840,
1650.39343,21.598,2728.96533,4.840,
1650.48486,21.598,2729.05688,3.840,
1650.57642,21.598,2729.14819,4.840,
1650.66797,21.598,2729.23975,3.840,
1650.75952,21.598,2729.33130,4.840,
1650.85095,21.598,2729.42285,4.840,
1650.94250,21.598,2729.51440,4.840,
1651.03406,21.598,2729.60596,4.840,
1651.12561,21.598,2729.69751,4.840,
1651.21704,22.598,2729.78882,3.840,
1651.30859,21.598,2729.88037,4.840,
1651.40015,21.598,2729.97192,3.840,
1651.49170,21.598,2730.06348,4.840,
1651.58313,21.598,2730.15503,4.840,
1651.67468,21.598,2730.24658,4.840,
1651.76624,22.598,2730.33813,4.840,
1651.85779,22.598,2730.42969,5.840,
1651.94922,22.598,2730.52100,4.840,
1652.04077,22.598,2730.61255,4.840,
1652.13232,21.598,2730.70410,4.840,
1652.22375,21.598,2730.79565,4.840,
1652.31531,21.598,2730.88721,4.840,
1652.40686,21.598,2730.97876,4.840,
1652.49841,22.598,2731.07031,4.840,
1652.58984,21.598,2731.16187,4.840,
1652.68140,22.598,2731.25317,4.840,
1652.77295,22.598,2731.34473,4.840,
1652.86450,22.598,2731.43628,4.840,
1652.95593,21.598,2731.52783,4.840,
1653.04749,21.598,2731.61938,4.840,
1653.13904,20.598,2731.71094,4.840,
1653.23059,20.598,2731.80249,4.840,
1653.32202,20.598,2731.89380,5.840,
1653.41357,20.598,2731.98535,4.840,
1653.50513,20.598,2732.07690,4.840,
1653.59668,20.598,2732.16846,4.840,
1653.68811,20.598,2732.26001,4.840,
1653.77966,20.598,2732.35156,4.840,
1653.87122,21.598,2732.44312,4.840,
1653.96265,21.598,2732.53467,4.840,
1654.05420,21.598,2732.62598,4.840,
1654.14575,22.598,2732.71753,3.840,
1654.23730,22.598,2732.80908,3.840,
1654.32874,22.598,2732.90063,4.840,
1654.42029,22.598,2732.99219,3.840,
1654.51184,22.598,2733.08374,3.840,
1654.60339,21.598,2733.17529,4.840,
1654.69482,21.598,2733.26685,4.840,
1654.78638,22.598,2733.35815,4.840,
1654.87793,22.598,2733.44971,4.840,
1654.96948,22.598,2733.54126,4.840,
1655.06091,21.598,2733.63281,3.840,
1655.15247,21.598,2733.72437,4.840,
1655.24402,21.598,2733.81592,4.840,
1655.33557,22.598,2733.90747,4.840,
1655.42700,21.598,2733.99878,4.840,
1655.51855,22.598,2734.09033,4.840,
1655.61011,22.598,2734.18188,4.840,
1655.70166,21.598,2734.27344,4.840,
1655.79309,21.598,2734.36499,4.840,
1655.88464,21.598,2734.45654,4.840,
1655.97620,22.598,2734.54810,4.840,
1656.06763,21.598,2734.63965,4.840,
1656.15918,22.598,2734.73096,4.840,
1656.25073,21.598,2734.82251,4.840,
1656.34229,22.598,2734.91406,4.840,
1656.43372,22.598,2735.00562,4.840,
1656.52527,21.598,2735.09717,4.840,
1656.61682,21.598,2735.18872,4.840,
1656.70837,22.598,2735.28027,4.840,
1656.79980,21.598,2735.37158,4.840,
1656.89136,21.598,2735.46313,4.840,
1656.98291,22.598,2735.55469,4.840,
1657.07446,22.598,2735.64624,4.840,
1657.16589,21.598,2735.73779,4.840,
1657.25745,21.598,2735.82935,4.840,
1657.34900,21.598,2735.92090,4.840,
1657.44055,21.598,2736.01245,4.840,
1657.53198,21.598,2736.10376,4.840,
1657.62354,22.598,2736.19531,4.840,
1657.71509,22.598,2736.28687,4.840,
1657.80652,22.598,2736.37842,4.840,
1657.89807,22.598,2736.46997,4.840,
1657.98962,22.598,2736.56152,4.840,
1658.08118,21.598,2736.65308,5.840,
1658.17261,22.598,2736.74463,4.840,
1658.26416,22.598,2736.83594,4.840,
1658.35571,22.598,2736.92749,5.840,
1658.44727,22.598,2737.01904,4.840,
1658.53870,22.598,2737.11060,5.840,
1658.63025,22.598,2737.20215,4.840,
1658.72180,22.598,2737.29370,4.840,
1658.81335,22.598,2737.38525,4.840,
1658.90479,22.598,2737.47656,4.840,
1658.99634,22.598,2737.56812,4.840,
1659.08789,22.598,2737.65967,4.840,
1659.17944,22.598,2737.75122,4.840,
1659.27087,22.598,2737.84277,5.840,
1659.36243,22.598,2737.93433,4.840,
1659.45398,22.598,2738.02588,4.840,
1659.54553,21.598,2738.11743,4.840,
1659.63696,21.598,2738.20874,4.840,
1659.72852,22.598,2738.30029,4.840,
1659.82007,22.598,2738.39185,4.840,
1659.91150,21.598,2738.48340,5.840,
1660.00305,22.598,2738.57495,4.840,
1660.09460,22.598,2738.66650,4.840,
1660.18616,22.598,2738.75806,4.840,
1660.27759,22.598,2738.84961,4.840,
1660.36914,22.598,2738.94092,4.840,
1660.46069,22.598,2739.03247,4.840,
1660.55225,22.598,2739.12402,4.840,
1660.64368,22.598,2739.21558,5.840,
1660.73523,22.598,2739.30713,4.840,
1660.82678,22.598,2739.39868,4.840,
1660.91833,22.598,2739.49023,4.840,
1661.00977,22.598,2739.58154,4.840,
1661.10132,22.598,2739.67310,4.840,
1661.19287,22.598,2739.76465,4.840,
1661.28442,22.598,2739.85620,5.840,
1661.37585,22.598,2739.94775,4.840,
1661.46741,22.598,2740.03931,4.840,
1661.55896,22.598,2740.13086,4.840,
1661.65039,22.598,2740.22241,4.840,
1661.74194,22.598,2740.31372,4.840,
1661.83350,22.598,2740.40527,4.840,
1661.92505,22.598,2740.49683,4.840,
1662.01648,21.598,2740.58838,4.840,
1662.10803,22.598,2740.67993,4.840,
1662.19958,22.598,2740.77148,4.840,
1662.29114,22.598,2740.86304,4.840,
1662.38257,21.598,2740.95435,4.840,
1662.47412,22.598,2741.04590,4.840,
1662.56567,22.598,2741.13745,4.840,
1662.65723,21.598,2741.22900,4.840,
1662.74866,22.598,2741.32056,4.840,
1662.84021,22.598,2741.41211,5.840,
1662.93176,22.598,2741.50366,4.840,
1663.02332,22.598,2741.59521,4.840,
1663.11475,22.598,2741.68652,4.840,
1663.20630,22.598,2741.77808,4.840,
1663.29785,22.598,2741.86963,4.840,
1663.38928,21.598,2741.96118,3.840,
1663.48083,22.598,2742.05273,4.840,
1663.57239,22.598,2742.14429,4.840,
1663.66394,22.598,2742.23584,4.840,
1663.75537,22.598,2742.32739,4.840,
1663.84692,22.598,2742.41870,4.840,
1663.93848,22.598,2742.51025,4.840,
1664.03003,22.598,2742.60181,4.840,
1664.12146,22.598,2742.69336,4.840,
1664.21301,21.598,2742.78491,4.840,
1664.30457,22.598,2742.87646,4.840,
1664.39612,22.598,2742.96802,4.840,
1664.48755,22.598,2743.05933,4.840,
1664.57910,22.598,2743.15088,4.840,
1664.67065,22.598,2743.24243,4.840,
1664.76221,22.598,2743.33398,4.840,
1664.85364,22.598,2743.42554,4.840,
1664.94519,23.598,2743.51709,4.840,
1665.03674,22.598,2743.60864,5.840,
1665.12830,22.598,2743.70020,4.840,
1665.21973,22.598,2743.79150,4.840,
1665.31128,22.598,2743.88306,5.840,
1665.40283,22.598,2743.97461,4.840,
1665.49426,22.598,2744.06616,4.840,
1665.58582,22.598,2744.15771,4.840,
1665.67737,22.598,2744.24927,4.840,
1665.76892,22.598,2744.34082,4.840,
1665.86035,23.598,2744.43237,4.840,
1665.95190,22.598,2744.52368,4.840,
1666.04346,22.598,2744.61523,4.840,
1666.13501,23.598,2744.70679,3.840,
1666.22644,22.598,2744.79834,3.840,
1666.31799,22.598,2744.88989,3.840,
1666.40955,22.598,2744.98145,3.840,
1666.50110,22.598,2745.07300,3.840,
1666.59253,22.598,2745.16431,3.840,
1666.68408,22.598,2745.25586,2.840,
1666.77563,22.598,2745.34741,2.840,
1666.86719,22.598,2745.43896,3.840,
1666.95862,22.598,2745.53052,3.840,
1667.05017,22.598,2745.62207,3.840,
1667.14172,23.598,2745.71362,3.840,
1667.23315,22.598,2745.80518,3.840,
1667.32471,23.598,2745.89648,3.840,
1667.41626,22.598,2745.98804,3.840,
1667.50781,22.598,2746.07959,4.840,
1667.59924,22.598,2746.17114,4.840,
1667.69080,23.598,2746.26270,3.840,
1667.78235,22.598,2746.35425,4.840,
1667.87390,22.598,2746.44580,4.840,
1667.96533,23.598,2746.53711,4.840,
1668.05688,23.598,2746.62866,4.840,
1668.14844,22.598,2746.72021,5.840,
1668.23999,23.598,2746.81177,4.840,
1668.33142,22.598,2746.90332,4.840,
1668.42297,22.598,2746.99487,4.840,
1668.51453,22.598,2747.08643,5.840,
1668.60608,22.598,2747.17798,4.840,
1668.69751,22.598,2747.26929,5.840,
1668.78906,23.598,2747.36084,4.840,
1668.88062,22.598,2747.45239,4.840,
1668.97217,22.598,2747.54395,4.840,
1669.06360,22.598,2747.63550,4.840,
1669.15515,22.598,2747.72705,4.840,
1669.24670,22.598,2747.81860,5.840,
1669.33813,23.598,2747.91016,4.840,
1669.42969,22.598,2748.00146,4.840,
1669.52124,23.598,2748.09302,4.840,
1669.61279,22.598,2748.18457,4.840,
1669.70422,22.598,2748.27612,5.840,
1669.79578,22.598,2748.36768,4.840,
1669.88733,22.598,2748.45923,4.840,
1669.97888,22.598,2748.55078,5.840,
1670.07031,22.598,2748.64209,4.840,
1670.16187,22.598,2748.73364,4.840,
1670.25342,23.598,2748.82520,4.840,
1670.34497,22.598,2748.91675,5.840,
1670.43640,22.598,2749.00830,4.840,
1670.52795,23.598,2749.09985,5.840,
1670.61951,22.598,2749.19141,4.840,
1670.71106,23.598,2749.28296,4.840,
1670.80249,22.598,2749.37427,4.840,
1670.89404,22.598,2749.46582,5.840,
1670.98560,22.598,2749.55737,4.840,
1671.07703,23.598,2749.64893,4.840,
1671.16858,23.598,2749.74048,5.840,
1671.26013,22.598,2749.83203,4.840,
1671.35168,23.598,2749.92358,4.840,
1671.44312,23.598,2750.01514,4.840,
1671.53467,23.598,2750.10645,4.840,
1671.62622,23.598,2750.19800,4.840,
1671.71777,23.598,2750.28955,4.840,
1671.80920,23.598,2750.38110,5.840,
1671.90076,23.598,2750.47266,4.840,
1671.99231,23.598,2750.56421,4.840,
1672.08386,23.598,2750.65576,4.840,
1672.17529,23.598,2750.74707,5.840,
1672.26685,23.598,2750.83862,4.840,
1672.35840,23.598,2750.93018,5.840,
1672.44995,23.598,2751.02173,4.840,
1672.54138,23.598,2751.11328,4.840,
1672.63293,23.598,2751.20483,4.840,
1672.72449,24.598,2751.29639,4.840,
1672.81592,24.598,2751.38794,4.840,
1672.90747,25.598,2751.47925,4.840,
1672.99902,24.598,2751.57080,4.840,
1673.09058,24.598,2751.66235,5.840,
1673.18201,25.598,2751.75391,4.840,
1673.27356,25.598,2751.84546,4.840,
1673.36511,25.598,2751.93701,4.840,
1673.45667,25.598,2752.02856,4.840,
1673.54810,25.598,2752.12012,4.840,
1673.63965,25.598,2752.21143,4.840,
1673.73120,24.598,2752.30298,4.840,
1673.82275,25.598,2752.39453,4.840,
1673.91418,24.598,2752.48608,4.840,
1674.00574,24.598,2752.57764,4.840,
1674.09729,24.598,2752.66919,4.840,
1674.18884,24.598,2752.76074,4.840,
1674.28027,24.598,2752.85205,5.840,
1674.37183,23.598,2752.94360,4.840,
1674.46338,24.598,2753.03516,4.840,
1674.55493,23.598,2753.12671,4.840,
1674.64636,23.598,2753.21826,4.840,
1674.73792,23.598,2753.30981,4.840,
1674.82947,23.598,2753.40137,4.840,
1674.92090,23.598,2753.49292,4.840,
1675.01245,23.598,2753.58423,4.840,
1675.10400,23.598,2753.67578,4.840,
1675.19556,23.598,2753.76733,4.840,
1675.28699,23.598,2753.85889,5.840,
1675.37854,23.598,2753.95044,4.840,
1675.47009,23.598,2754.04199,4.840,
1675.56165,23.598,2754.13354,5.840,
1675.65308,23.598,2754.22485,4.840,
1675.74463,23.598,2754.31641,4.840,
1675.83618,23.598,2754.40796,4.840,
1675.92773,23.598,2754.49951,4.840,
1676.01917,23.598,2754.59106,4.840,
1676.11072,23.598,2754.68262,4.840,
1676.20227,23.598,2754.77417,4.840,
1676.29382,23.598,2754.86572,4.840,
1676.38525,23.598,2754.95703,4.840,
1676.47681,23.598,2755.04858,4.840,
1676.56836,24.598,2755.14014,4.840,
1676.65979,23.598,2755.23169,5.840,
1676.75134,23.598,2755.32324,5.840,
1676.84290,23.598,2755.41479,4.840,
1676.93445,24.598,2755.50635,5.840,
1677.02588,23.598,2755.59790,5.840,
1677.11743,24.598,2755.68921,5.840,
1677.20898,23.598,2755.78076,4.840,
1677.30054,23.598,2755.87231,4.840,
1677.39197,23.598,2755.96387,4.840,
1677.48352,23.598,2756.05542,5.840,
1677.57507,24.598,2756.14697,4.840,
1677.66663,23.598,2756.23853,4.840,
1677.75806,23.598,2756.32983,4.840,
1677.84961,24.598,2756.42139,5.840,
1677.94116,23.598,2756.51294,4.840,
1678.03271,23.598,2756.60449,4.840,
1678.12415,24.598,2756.69604,4.840,
1678.21570,23.598,2756.78760,5.840,
1678.30725,23.598,2756.87915,4.840,
1678.39880,24.598,2756.97070,4.840,
1678.49023,23.598,2757.06201,5.840,
1678.58179,23.598,2757.15356,4.840,
1678.67334,23.598,2757.24512,5.840,
1678.76477,23.598,2757.33667,4.840,
1678.85632,23.598,2757.42822,5.840,
1678.94788,23.598,2757.51978,5.840,
1679.03943,24.598,2757.61133,4.840,
1679.13086,24.598,2757.70288,4.840,
1679.22241,23.598,2757.79419,5.840,
1679.31396,23.598,2757.88574,4.840,
1679.40552,24.598,2757.97729,5.840,
1679.49695,23.598,2758.06885,5.840,
1679.58850,24.598,2758.16040,4.840,
1679.68005,24.598,2758.25195,5.840,
1679.77161,23.598,2758.34351,4.840,
1679.86304,23.598,2758.43481,5.840,
1679.95459,24.598,2758.52637,4.840,
1680.04614,24.598,2758.61792,4.840,
1680.13770,24.598,2758.70947,4.840,
1680.22913,24.598,2758.80103,4.840,
1680.32068,24.598,2758.89258,4.840,
1680.41223,24.598,2758.98413,4.840,
1680.50366,24.598,2759.07568,4.840,
1680.59521,24.598,2759.16699,4.840,
1680.68677,24.598,2759.25854,4.840,
1680.77832,24.598,2759.35010,4.840,
1680.86975,24.598,2759.44165,4.840,
1680.96130,24.598,2759.53320,4.840,
1681.05286,24.598,2759.62476,5.840,
1681.14441,24.598,2759.71631,4.840,
1681.23584,24.598,2759.80762,5.840,
1681.32739,23.598,2759.89917,4.840,
1681.41895,24.598,2759.99072,5.840,
1681.51050,24.598,2760.08228,4.840,
1681.60193,23.598,2760.17383,5.840,
1681.69348,23.598,2760.26538,4.840,
1681.78503,24.598,2760.35693,4.840,
1681.87659,24.598,2760.44849,5.840,
1681.96802,24.598,2760.53979,4.840,
1682.05957,24.598,2760.63135,4.840,
1682.15112,24.598,2760.72290,4.840,
1682.24255,24.598,2760.81445,4.840,
1682.33411,24.598,2760.90601,5.840,
1682.42566,24.598,2760.99756,4.840,
1682.51721,24.598,2761.08911,5.840,
1682.60864,24.598,2761.18066,5.840,
1682.70020,24.598,2761.27197,4.840,
1682.79175,24.598,2761.36353,4.840,
1682.88330,24.598,2761.45508,5.840,
1682.97473,24.598,2761.54663,4.840,
1683.06628,24.598,2761.63818,4.840,
1683.15784,23.598,2761.72974,4.840,
1683.24939,24.598,2761.82129,4.840,
1683.34082,23.598,2761.91260,4.840,
1683.43237,24.598,2762.00415,4.840,
1683.52393,24.598,2762.09570,4.840,
1683.61548,24.598,2762.18726,4.840,
1683.70691,24.598,2762.27881,4.840,
1683.79846,24.598,2762.37036,4.840,
1683.89001,24.598,2762.46191,4.840,
1683.98157,24.598,2762.55347,4.840,
1684.07300,24.598,2762.64478,5.840,
1684.16455,24.598,2762.73633,4.840,
1684.25610,24.598,2762.82788,4.840,
1684.34753,24.598,2762.91943,4.840,
1684.43909,24.598,2763.01099,5.840,
1684.53064,24.598,2763.10254,4.840,
1684.62219,24.598,2763.19409,4.840,
1684.71362,24.598,2763.28564,4.840,
1684.80518,24.598,2763.37695,4.840,
1684.89673,25.598,2763.46851,4.840,
1684.98828,24.598,2763.56006,4.840,
1685.07971,24.598,2763.65161,4.840,
1685.17126,24.598,2763.74316,4.840,
1685.26282,24.598,2763.83472,4.840,
1685.35437,24.598,2763.92627,4.840,
1685.44580,24.598,2764.01758,4.840,
1685.53735,24.598,2764.10913,5.840,
1685.62891,24.598,2764.20068,6.840,
1685.72046,24.598,2764.29224,6.840,
1685.81189,24.598,2764.38379,7.840,
1685.90344,24.598,2764.47534,7.840,
1685.99500,24.598,2764.56689,7.840,
1686.08643,24.598,2764.65845,8.840,
1686.17798,24.598,2764.74976,8.840,
1686.26953,24.598,2764.84131,8.840,
1686.36108,24.598,2764.93286,7.840,
1686.45251,25.598,2765.02441,6.840,
1686.54407,24.598,2765.11597,6.840,
1686.63562,24.598,2765.20752,7.840,
1686.72717,25.598,2765.29907,5.840,
1686.81860,24.598,2765.39038,6.840,
1686.91016,24.598,2765.48193,5.840,
1687.00171,25.598,2765.57349,6.840,
1687.09326,24.598,2765.66504,5.840,
1687.18469,24.598,2765.75659,5.840,
1687.27625,24.598,2765.84814,5.840,
1687.36780,24.598,2765.93970,5.840,
1687.45935,24.598,2766.03125,4.840,
1687.55078,24.598,2766.12256,4.840,
1687.64233,24.598,2766.21411,5.840,
1687.73389,24.598,2766.30566,4.840,
1687.82544,25.598,2766.39722,4.840,
1687.91687,24.598,2766.48877,4.840,
1688.00842,24.598,2766.58032,4.840,
1688.09998,24.598,2766.67188,4.840,
1688.19141,24.598,2766.76343,4.840,
1688.28296,24.598,2766.85474,3.840,
1688.37451,24.598,2766.94629,4.840,
1688.46606,24.598,2767.03784,4.840,
1688.55750,24.598,2767.12939,3.840,
1688.64905,24.598,2767.22095,4.840,
1688.74060,24.598,2767.31250,3.840,
1688.83215,24.598,2767.40405,4.840,
1688.92358,24.598,2767.49536,4.840,
1689.01514,24.598,2767.58691,4.840,
1689.10669,24.598,2767.67847,4.840,
1689.19824,25.598,2767.77002,4.840,
1689.28967,25.598,2767.86157,4.840,
1689.38123,24.598,2767.95313,4.840,
1689.47278,24.598,2768.04468,4.840,
1689.56433,25.598,2768.13623,4.840,
1689.65576,24.598,2768.22754,5.840,
1689.74731,24.598,2768.31909,4.840,
1689.83887,25.598,2768.41064,4.840,
1689.93030,24.598,2768.50220,5.840,
1690.02185,25.598,2768.59375,4.840,
1690.11340,25.598,2768.68530,5.840,
1690.20496,24.598,2768.77686,5.840,
1690.29639,25.598,2768.86841,4.840,
1690.38794,24.598,2768.95972,4.840,
1690.47949,25.598,2769.05127,4.840,
1690.57104,25.598,2769.14282,5.840,
1690.66248,25.598,2769.23438,4.840,
1690.75403,25.598,2769.32593,4.840,
1690.84558,25.598,2769.41748,4.840,
1690.93713,24.598,2769.50903,4.840,
1691.02856,25.598,2769.60034,4.840,
1691.12012,25.598,2769.69189,5.840,
1691.21167,24.598,2769.78345,4.840,
1691.30322,25.598,2769.87500,4.840,
1691.39465,25.598,2769.96655,5.840,
1691.48621,24.598,2770.05811,4.840,
1691.57776,25.598,2770.14966,5.840,
1691.66919,24.598,2770.24121,5.840,
1691.76074,25.598,2770.33252,5.840,
1691.85229,25.598,2770.42407,4.840,
1691.94385,25.598,2770.51563,4.840,
1692.03528,25.598,2770.60718,5.840,
1692.12683,25.598,2770.69873,5.840,
1692.21838,25.598,2770.79028,4.840,
1692.30994,25.598,2770.88184,4.840,
1692.40137,25.598,2770.97339,5.840,
1692.49292,25.598,2771.06470,4.840,
1692.58447,25.598,2771.15625,4.840,
1692.67603,25.598,2771.24780,4.840,
1692.76746,25.598,2771.33936,4.840,
1692.85901,25.598,2771.43091,5.840,
1692.95056,25.598,2771.52246,4.840,
1693.04211,25.598,2771.61401,4.840,
1693.13354,25.598,2771.70532,5.840,
1693.22510,25.598,2771.79688,4.840,
1693.31665,24.598,2771.88843,5.840,
1693.40820,24.598,2771.97998,4.840,
1693.49963,24.598,2772.07153,4.840,
1693.59119,24.598,2772.16309,5.840,
1693.68274,24.598,2772.25464,4.840,
1693.77417,24.598,2772.34619,4.840,
1693.86572,24.598,2772.43750,4.840,
1693.95728,24.598,2772.52905,4.840,
1694.04883,24.598,2772.62061,4.840,
1694.14026,24.598,2772.71216,4.840,
1694.23181,25.598,2772.80371,5.840,
1694.32336,25.598,2772.89526,4.840,
1694.41492,25.598,2772.98682,4.840,
1694.50635,25.598,2773.07813,4.840,
1694.59790,24.598,2773.16968,4.840,
1694.68945,25.598,2773.26123,4.840,
1694.78101,25.598,2773.35278,5.840,
1694.87244,25.598,2773.44434,4.840,
1694.96399,25.598,2773.53589,4.840,
1695.05554,25.598,2773.62744,5.840,
1695.14709,26.598,2773.71899,4.840,
1695.23853,25.598,2773.81030,4.840,
1695.33008,25.598,2773.90186,4.840,
1695.42163,25.598,2773.99341,5.840,
1695.51306,25.598,2774.08496,4.840,
1695.60461,25.598,2774.17651,4.840,
1695.69617,25.598,2774.26807,5.840,
1695.78772,25.598,2774.35962,5.840,
1695.87915,25.598,2774.45117,5.840,
1695.97070,25.598,2774.54248,5.840,
1696.06226,25.598,2774.63403,4.840,
1696.15381,25.598,2774.72559,4.840,
1696.24524,25.598,2774.81714,4.840,
1696.33679,25.598,2774.90869,5.840,
1696.42834,25.598,2775.00024,5.840,
1696.51990,25.598,2775.09180,4.840,
1696.61133,26.598,2775.18311,4.840,
1696.70288,25.598,2775.27466,4.840,
1696.79443,25.598,2775.36621,4.840,
1696.88599,25.598,2775.45776,4.840,
1696.97742,25.598,2775.54932,4.840,
1697.06897,25.598,2775.64087,4.840,
1697.16052,25.598,2775.73242,4.840,
1697.25208,25.598,2775.82397,5.840,
1697.34351,25.598,2775.91528,5.840,
1697.43506,25.598,2776.00684,4.840,
1697.52661,25.598,2776.09839,4.840,
1697.61804,25.598,2776.18994,5.840,
1697.70959,25.598,2776.28149,5.840,
1697.80115,26.598,2776.37305,4.840,
1697.89270,25.598,2776.46460,4.840,
1697.98413,25.598,2776.55615,4.840,
1698.07568,26.598,2776.64746,4.840,
1698.16724,26.598,2776.73901,4.840,
1698.25879,26.598,2776.83057,4.840,
1698.35022,26.598,2776.92212,4.840,
1698.44177,26.598,2777.01367,5.840,
1698.53333,26.598,2777.10522,4.840,
1698.62488,25.598,2777.19678,4.840,
1698.71631,26.598,2777.28809,5.840,
1698.80786,25.598,2777.37964,5.840,
1698.89941,25.598,2777.47119,5.840,
1698.99097,25.598,2777.56274,5.840,
1699.08240,25.598,2777.65430,5.840,
1699.17395,25.598,2777.74585,4.840,
1699.26550,25.598,2777.83740,4.840,
1699.35693,25.598,2777.92896,5.840,
1699.44849,25.598,2778.02026,4.840,
1699.54004,26.598,2778.11182,4.840,
1699.63159,25.598,2778.20337,4.840,
1699.72302,25.598,2778.29492,4.840,
1699.81458,25.598,2778.38647,4.840,
1699.90613,25.598,2778.47803,4.840,
1699.99768,25.598,2778.56958,4.840,
1700.08911,25.598,2778.66089,5.840,
1700.18066,25.598,2778.75244,5.840,
1700.27222,26.598,2778.84399,5.840,
1700.36377,25.598,2778.93555,5.840,
1700.45520,26.598,2779.02710,5.840,
1700.54675,25.598,2779.11865,5.840,
1700.63831,26.598,2779.21021,5.840,
1700.72986,25.598,2779.30176,4.840,
1700.82129,26.598,2779.39307,5.840,
1700.91284,26.598,2779.48462,5.840,
1701.00439,26.598,2779.57617,4.840,
1701.09583,26.598,2779.66772,4.840,
1701.18738,26.598,2779.75928,4.840,
1701.27893,26.598,2779.85083,4.840,
1701.37048,26.598,2779.94238,4.840,
1701.46191,26.598,2780.03394,4.840,
1701.55347,26.598,2780.12524,4.840,
1701.64502,26.598,2780.21680,5.840,
1701.73657,25.598,2780.30835,5.840,
1701.82800,25.598,2780.39990,5.840,
1701.91956,25.598,2780.49146,4.840,
1702.01111,26.598,2780.58301,4.840,
1702.10266,26.598,2780.67456,5.840,
1702.19409,26.598,2780.76587,5.840,
1702.28564,25.598,2780.85742,5.840,
1702.37720,26.598,2780.94897,4.840,
1702.46875,26.598,2781.04053,5.840,
1702.56018,26.598,2781.13208,4.840,
1702.65173,26.598,2781.22363,5.840,
1702.74329,26.598,2781.31519,5.840,
1702.83484,25.598,2781.40674,5.840,
1702.92627,26.598,2781.49805,4.840,
1703.01782,26.598,2781.58960,5.840,
1703.10938,26.598,2781.68115,5.840,
1703.20081,26.598,2781.77271,5.840,
1703.29236,26.598,2781.86426,5.840,
1703.38391,25.598,2781.95581,5.840,
1703.47546,26.598,2782.04736,4.840,
1703.56689,26.598,2782.13892,4.840,
1703.65845,26.598,2782.23022,4.840,
1703.75000,26.598,2782.32178,4.840,
1703.84155,26.598,2782.41333,4.840,
1703.93298,26.598,2782.50488,5.840,
1704.02454,25.598,2782.59644,5.840,
1704.11609,25.598,2782.68799,5.840,
1704.20764,26.598,2782.77954,5.840,
1704.29907,26.598,2782.87085,5.840,
1704.39063,26.598,2782.96240,4.840,
1704.48218,26.598,2783.05396,4.840,
1704.57373,26.598,2783.14551,5.840,
1704.66516,25.598,2783.23706,5.840,
1704.75671,26.598,2783.32861,5.840,
1704.84827,26.598,2783.42017,5.840,
1704.93970,26.598,2783.51172,5.840,
1705.03125,26.598,2783.60303,5.840,
1705.12280,26.598,2783.69458,5.840,
1705.21436,26.598,2783.78613,5.840,
1705.30579,26.598,2783.87769,5.840,
1705.39734,27.598,2783.96924,5.840,
1705.48889,26.598,2784.06079,5.840,
1705.58044,26.598,2784.15234,5.840,
1705.67188,26.598,2784.24365,4.840,
1705.76343,27.598,2784.33521,5.840,
1705.85498,26.598,2784.42676,4.840,
1705.94653,26.598,2784.51831,5.840,
1706.03796,27.598,2784.60986,5.840,
1706.12952,26.598,2784.70142,5.840,
1706.22107,26.598,2784.79297,5.840,
1706.31262,26.598,2784.88452,5.840,
1706.40405,26.598,2784.97583,5.840,
1706.49561,26.598,2785.06738,5.840,
1706.58716,26.598,2785.15894,5.840,
1706.67871,26.598,2785.25049,5.840,
1706.77014,26.598,2785.34204,5.840,
1706.86169,26.598,2785.43359,5.840,
1706.95325,26.598,2785.52515,5.840,
1707.04468,26.598,2785.61670,5.840,
1707.13623,26.598,2785.70801,5.840,
1707.22778,26.598,2785.79956,5.840,
1707.31934,26.598,2785.89111,5.840,
1707.41077,26.598,2785.98267,5.840,
1707.50232,26.598,2786.07422,5.840,
1707.59387,26.598,2786.16577,4.840,
1707.68542,26.598,2786.25732,5.840,
1707.77686,26.598,2786.34863,4.840,
1707.86841,26.598,2786.44019,3.840,
1707.95996,26.598,2786.53174,4.840,
1708.05151,26.598,2786.62329,4.840,
1708.14294,26.598,2786.71484,4.840,
1708.23450,26.598,2786.80640,4.840,
1708.32605,27.598,2786.89795,4.840,
1708.41760,26.598,2786.98950,4.840,
1708.50903,26.598,2787.08081,4.840,
1708.60059,26.598,2787.17236,4.840,
1708.69214,26.598,2787.26392,4.840,
1708.78357,26.598,2787.35547,4.840,
1708.87512,26.598,2787.44702,5.840,
1708.96667,26.598,2787.53857,5.840,
1709.05823,26.598,2787.63013,5.840,
1709.14966,26.598,2787.72168,5.840,
1709.24121,26.598,2787.81299,5.840,
1709.33276,26.598,2787.90454,5.840,
1709.42432,27.598,2787.99609,5.840,
1709.51575,26.598,2788.08765,5.840,
1709.60730,26.598,2788.17920,5.840,
1709.69885,26.598,2788.27075,5.840,
1709.79041,27.598,2788.36230,5.840,
1709.88184,26.598,2788.45361,5.840,
1709.97339,26.598,2788.54517,5.840,
1710.06494,26.598,2788.63672,5.840,
1710.15649,27.598,2788.72827,5.840,
1710.24792,26.598,2788.81982,5.840,
1710.33948,27.598,2788.91138,5.840,
1710.43103,26.598,2789.00293,6.840,
1710.52246,26.598,2789.09448,6.840,
1710.61401,26.598,2789.18579,5.840,
1710.70557,26.598,2789.27734,5.840,
1710.79712,26.598,2789.36890,5.840,
1710.88855,26.598,2789.46045,5.840,
1710.98010,27.598,2789.55200,5.840,
1711.07166,27.598,2789.64355,5.840,
1711.16321,27.598,2789.73511,5.840,
1711.25464,27.598,2789.82666,5.840,
1711.34619,27.598,2789.91797,5.840,
1711.43774,27.598,2790.00952,5.840,
1711.52930,27.598,2790.10107,5.840,
1711.62073,27.598,2790.19263,6.840,
1711.71228,26.598,2790.28418,5.840,
1711.80383,27.598,2790.37573,5.840,
1711.89539,27.598,2790.46729,5.840,
1711.98682,27.598,2790.55859,5.840,
1712.07837,27.598,2790.65015,5.840,
1712.16992,27.598,2790.74170,5.840,
1712.26147,27.598,2790.83325,5.840,
1712.35291,27.598,2790.92480,5.840,
1712.44446,27.598,2791.01636,5.840,
1712.53601,27.598,2791.10791,5.840,
1712.62744,27.598,2791.19946,5.840,
1712.71899,27.598,2791.29077,5.840,
1712.81055,27.598,2791.38232,5.840,
1712.90210,27.598,2791.47388,5.840,
1712.99353,27.598,2791.56543,5.840,
1713.08508,27.598,2791.65698,5.840,
1713.17664,27.598,2791.74854,5.840,
1713.26819,27.598,2791.84009,5.840,
1713.35962,27.598,2791.93140,5.840,
1713.45117,27.598,2792.02295,5.840,
1713.54272,26.598,2792.11450,5.840,
1713.63428,27.598,2792.20605,5.840,
1713.72571,27.598,2792.29761,5.840,
1713.81726,26.598,2792.38916,6.840,
1713.90881,27.598,2792.48071,5.840,
1714.00037,27.598,2792.57227,5.840,
1714.09180,27.598,2792.66357,5.840,
1714.18335,27.598,2792.75513,5.840,
1714.27490,27.598,2792.84668,5.840,
1714.36633,27.598,2792.93823,5.840,
1714.45789,27.598,2793.02979,5.840,
1714.54944,27.598,2793.12134,5.840,
1714.64099,27.598,2793.21289,5.840,
1714.73242,26.598,2793.30444,6.840,
1714.82397,26.598,2793.39575,5.840,
1714.91553,26.598,2793.48730,5.840,
1715.00708,26.598,2793.57886,5.840,
1715.09851,26.598,2793.67041,6.840,
1715.19006,26.598,2793.76196,5.840,
1715.28162,26.598,2793.85352,5.840,
1715.37317,26.598,2793.94507,6.840,
1715.46460,26.598,2794.03638,6.840,
1715.55615,26.598,2794.12793,5.840,
1715.64771,27.598,2794.21948,6.840,
1715.73926,26.598,2794.31104,6.840,
1715.83069,26.598,2794.40259,5.840,
1715.92224,27.598,2794.49414,6.840,
1716.01379,27.598,2794.58569,6.840,
1716.10535,27.598,2794.67725,5.840,
1716.19678,27.598,2794.76855,6.840,
1716.28833,27.598,2794.86011,6.840,
1716.37988,27.598,2794.95166,6.840,
1716.47131,27.598,2795.04321,6.840,
1716.56287,27.598,2795.13477,5.840,
1716.65442,27.598,2795.22632,6.840,
1716.74597,27.598,2795.31787,6.840,
1716.83740,27.598,2795.40942,6.840,
1716.92896,27.598,2795.50073,6.840,
1717.02051,27.598,2795.59229,5.840,
1717.11206,28.598,2795.68384,6.840,
1717.20349,27.598,2795.77539,6.840,
1717.29504,27.598,2795.86694,5.840,
1717.38660,27.598,2795.95850,5.840,
1717.47815,27.598,2796.05005,6.840,
1717.56958,27.598,2796.14136,5.840,
1717.66113,27.598,2796.23291,5.840,
1717.75269,27.598,2796.32446,6.840,
1717.84424,27.598,2796.41602,6.840,
1717.93567,27.598,2796.50757,6.840,
1718.02722,27.598,2796.59912,6.840,
1718.11877,27.598,2796.69067,6.840,
1718.21021,27.598,2796.78223,6.840,
1718.30176,27.598,2796.87354,6.840,
1718.39331,28.598,2796.96509,6.840,
1718.48486,27.598,2797.05664,6.840,
1718.57629,27.598,2797.14819,6.840,
1718.66785,27.598,2797.23975,6.840,
1718.75940,27.598,2797.33130,6.840,
1718.85095,27.598,2797.42285,6.840,
1718.94238,27.598,2797.51416,6.840,
1719.03394,27.598,2797.60571,6.840,
1719.12549,27.598,2797.69727,6.840,
1719.21704,27.598,2797.78882,7.840,
1719.30847,28.598,2797.88037,6.840,
1719.40002,27.598,2797.97192,6.840,
1719.49158,28.598,2798.06348,6.840,
1719.58313,27.598,2798.15503,6.840,
1719.67456,27.598,2798.24634,6.840,
1719.76611,27.598,2798.33789,6.840,
1719.85767,27.598,2798.42944,6.840,
1719.94910,27.598,2798.52100,6.840,
1720.04065,27.598,2798.61255,6.840,
1720.13220,27.598,2798.70410,6.840,
1720.22375,27.598,2798.79565,6.840,
1720.31519,27.598,2798.88721,6.840,
1720.40674,27.598,2798.97852,6.840,
1720.49829,27.598,2799.07007,6.840,
1720.58984,27.598,2799.16162,6.840,
1720.68127,27.598,2799.25317,6.840,
1720.77283,27.598,2799.34473,6.840,
1720.86438,27.598,2799.43628,6.840,
1720.95593,27.598,2799.52783,6.840,
1721.04736,27.598,2799.61914,6.840,
1721.13892,28.598,2799.71069,7.840,
1721.23047,27.598,2799.80225,7.840,
1721.32202,27.598,2799.89380,6.840,
1721.41345,27.598,2799.98535,6.840,
1721.50500,28.598,2800.07690,6.840,
1721.59656,27.598,2800.16846,7.840,
1721.68811,28.598,2800.26001,6.840,
1721.77954,28.598,2800.35132,7.840,
1721.87109,27.598,2800.44287,7.840,
1721.96265,28.598,2800.53442,5.840,
1722.05408,28.598,2800.62598,6.840,
1722.14563,27.598,2800.71753,7.840,
1722.23718,28.598,2800.80908,6.840,
1722.32874,28.598,2800.90063,6.840,
1722.42017,27.598,2800.99219,6.840,
1722.51172,27.598,2801.08350,6.840,
1722.60327,27.598,2801.17505,7.840,
1722.69482,28.598,2801.26660,6.840,
1722.78625,27.598,2801.35815,7.840,
1722.87781,28.598,2801.44971,6.840,
1722.96936,28.598,2801.54126,7.840,
1723.06091,28.598,2801.63281,6.840,
1723.15234,27.598,2801.72412,6.840,
1723.24390,28.598,2801.81567,6.840,
1723.33545,27.598,2801.90723,6.840,
1723.42700,27.598,2801.99878,6.840,
1723.51843,28.598,2802.09033,6.840,
1723.60999,28.598,2802.18188,7.840,
1723.70154,28.598,2802.27344,7.840,
1723.79297,28.598,2802.36499,6.840,
1723.88452,27.598,2802.45630,6.840,
1723.97607,28.598,2802.54785,7.840,
1724.06763,28.598,2802.63940,5.840,
1724.15906,28.598,2802.73096,6.840,
1724.25061,28.598,2802.82251,6.840,
1724.34216,27.598,2802.91406,6.840,
1724.43372,28.598,2803.00562,6.840,
1724.52515,28.598,2803.09692,6.840,
1724.61670,28.598,2803.18848,6.840,
1724.70825,28.598,2803.28003,6.840,
1724.79980,28.598,2803.37158,6.840,
1724.89124,28.598,2803.46313,7.840,
1724.98279,27.598,2803.55469,6.840,
1725.07434,28.598,2803.64624,7.840,
1725.16589,28.598,2803.73779,7.840,
1725.25732,28.598,2803.82910,7.840,
1725.34888,28.598,2803.92065,6.840,
1725.44043,28.598,2804.01221,6.840,
1725.53186,27.598,2804.10376,6.840,
1725.62341,28.598,2804.19531,6.840,
1725.71497,28.598,2804.28687,6.840,
1725.80652,28.598,2804.37842,7.840,
1725.89795,28.598,2804.46997,6.840,
1725.98950,28.598,2804.56128,6.840,
1726.08105,28.598,2804.65283,7.840,
1726.17261,27.598,2804.74438,6.840,
1726.26404,28.598,2804.83594,6.840,
1726.35559,28.598,2804.92749,7.840,
1726.44714,27.598,2805.01904,7.840,
1726.53870,28.598,2805.11060,7.840,
1726.63013,29.598,2805.20190,7.840,
1726.72168,27.598,2805.29346,7.840,
1726.81323,28.598,2805.38501,7.840,
1726.90479,28.598,2805.47656,7.840,
1726.99622,28.598,2805.56812,7.840,
1727.08777,27.598,2805.65967,7.840,
1727.17932,28.598,2805.75122,6.840,
1727.27087,28.598,2805.84277,6.840,
1727.36230,28.598,2805.93408,7.840,
1727.45386,28.598,2806.02563,6.840,
1727.54541,28.598,2806.11719,6.840,
1727.63684,28.598,2806.20874,7.840,
1727.72839,28.598,2806.30029,6.840,
1727.81995,29.598,2806.39185,7.840,
1727.91150,28.598,2806.48340,6.840,
1728.00293,28.598,2806.57495,6.840,
1728.09448,28.598,2806.66626,7.840,
1728.18604,28.598,2806.75781,6.840,
1728.27759,28.598,2806.84937,7.840,
1728.36902,28.598,2806.94092,6.840,
1728.46057,28.598,2807.03247,7.840,
1728.55212,28.598,2807.12402,6.840,
1728.64368,28.598,2807.21558,7.840,
1728.73511,28.598,2807.30688,6.840,
1728.82666,29.598,2807.39844,7.840,
1728.91821,28.598,2807.48999,6.840,
1729.00977,28.598,2807.58154,6.840,
1729.10120,28.598,2807.67310,7.840,
1729.19275,28.598,2807.76465,6.840,
1729.28430,28.598,2807.85620,7.840,
1729.37573,29.598,2807.94775,7.840,
1729.46729,29.598,2808.03906,8.840,
1729.55884,29.598,2808.13062,7.840,
1729.65039,29.598,2808.22217,7.840,
1729.74182,28.598,2808.31372,8.840,
1729.83337,29.598,2808.40527,8.840,
1729.92493,28.598,2808.49683,7.840,
1730.01648,29.598,2808.58838,7.840,
1730.10791,28.598,2808.67993,8.840,
1730.19946,29.598,2808.77124,7.840,
1730.29102,30.598,2808.86279,7.840,
1730.38257,28.598,2808.95435,8.840,
1730.47400,28.598,2809.04590,8.840,
1730.56555,29.598,2809.13745,7.840,
1730.65710,28.598,2809.22900,7.840,
1730.74866,29.598,2809.32056,7.840,
1730.84009,29.598,2809.41187,7.840,
1730.93164,29.598,2809.50342,8.840,
1731.02319,28.598,2809.59497,7.840,
1731.11475,28.598,2809.68652,7.840,
1731.20618,29.598,2809.77808,7.840,
1731.29773,29.598,2809.86963,7.840,
1731.38928,29.598,2809.96118,7.840,
1731.48071,28.598,2810.05273,7.840,
1731.57227,28.598,2810.14404,7.840,
1731.66382,28.598,2810.23560,6.840,
1731.75537,29.598,2810.32715,6.840,
1731.84680,29.598,2810.41870,6.840,
1731.93835,29.598,2810.51025,5.840,
1732.02991,29.598,2810.60181,5.840,
1732.12146,29.598,2810.69336,5.840,
1732.21289,29.598,2810.78467,5.840,
1732.30444,29.598,2810.87622,5.840,
1732.39600,29.598,2810.96777,5.840,
1732.48755,29.598,2811.05933,6.840,
1732.57898,29.598,2811.15088,6.840,
1732.67053,28.598,2811.24243,5.840,
1732.76208,28.598,2811.33398,6.840,
1732.85364,28.598,2811.42554,6.840,
1732.94507,28.598,2811.51685,6.840,
1733.03662,29.598,2811.60840,6.840,
1733.12817,29.598,2811.69995,6.840,
1733.21960,29.598,2811.79150,7.840,
1733.31116,28.598,2811.88306,6.840,
1733.40271,28.598,2811.97461,7.840,
1733.49426,28.598,2812.06616,7.840,
1733.58569,28.598,2812.15771,7.840,
1733.67725,28.598,2812.24902,7.840,
1733.76880,28.598,2812.34058,7.840,
1733.86035,28.598,2812.43213,7.840,
1733.95178,27.598,2812.52368,6.840,
1734.04333,28.598,2812.61523,7.840,
1734.13489,27.598,2812.70679,7.840,
1734.22644,28.598,2812.79834,7.840,
1734.31787,28.598,2812.88965,7.840,
1734.40942,28.598,2812.98120,7.840,
1734.50098,28.598,2813.07275,7.840,
1734.59253,29.598,2813.16431,6.840,
1734.68396,29.598,2813.25586,6.840,
1734.77551,28.598,2813.34741,7.840,
1734.86707,28.598,2813.43896,6.840,
1734.95850,29.598,2813.53052,7.840,
1735.05005,28.598,2813.62183,7.840,
1735.14160,29.598,2813.71338,7.840,
1735.23315,29.598,2813.80493,7.840,
1735.32458,29.598,2813.89648,7.840,
1735.41614,28.598,2813.98804,7.840,
1735.50769,29.598,2814.07959,6.840,
1735.59924,29.598,2814.17114,7.840,
1735.69067,29.598,2814.26270,7.840,
1735.78223,29.598,2814.35400,7.840,
1735.87378,29.598,2814.44556,7.840,
1735.96533,29.598,2814.53711,7.840,
1736.05676,29.598,2814.62866,7.840,
1736.14832,29.598,2814.72021,7.840,
1736.23987,29.598,2814.81177,7.840,
1736.33142,28.598,2814.90332,7.840,
1736.42285,29.598,2814.99463,7.840,
1736.51440,29.598,2815.08618,7.840,
1736.60596,28.598,2815.17773,7.840,
1736.69751,29.598,2815.26929,7.840,
1736.78894,29.598,2815.36084,8.840,
1736.88049,29.598,2815.45239,7.840,
1736.97205,29.598,2815.54395,7.840,
1737.06348,29.598,2815.63550,7.840,
1737.15503,29.598,2815.72681,7.840,
1737.24658,29.598,2815.81836,7.840,
1737.33813,29.598,2815.90991,7.840,
1737.42957,29.598,2816.00146,7.840,
1737.52112,29.598,2816.09302,8.840,
1737.61267,30.598,2816.18457,7.840,
1737.70422,29.598,2816.27612,8.840,
1737.79565,29.598,2816.36743,7.840,
1737.88721,29.598,2816.45898,7.840,
1737.97876,29.598,2816.55054,7.840,
1738.07031,29.598,2816.64209,7.840,
1738.16174,29.598,2816.73364,7.840,
1738.25330,29.598,2816.82520,7.840,
1738.34485,29.598,2816.91675,8.840,
1738.43640,29.598,2817.00830,7.840,
1738.52783,29.598,2817.09961,7.840,
1738.61938,29.598,2817.19116,7.840,
1738.71094,29.598,2817.28271,7.840,
1738.80237,29.598,2817.37427,7.840,
1738.89392,29.598,2817.46582,7.840,
1738.98547,29.598,2817.55737,7.840,
1739.07703,29.598,2817.64893,7.840,
1739.16846,30.598,2817.74048,7.840,
1739.26001,29.598,2817.83179,7.840,
1739.35156,29.598,2817.92334,7.840,
1739.44312,29.598,2818.01489,7.840,
1739.53455,30.598,2818.10645,8.840,
1739.62610,29.598,2818.19800,8.840,
1739.71765,29.598,2818.28955,8.840,
1739.80920,29.598,2818.38110,8.840,
1739.90063,29.598,2818.47241,8.840,
1739.99219,29.598,2818.56396,7.840,
1740.08374,29.598,2818.65552,7.840,
1740.17529,29.598,2818.74707,7.840,
1740.26672,28.598,2818.83862,7.840,
1740.35828,29.598,2818.93018,7.840,
1740.44983,29.598,2819.02173,7.840,
1740.54138,30.598,2819.11328,7.840,
1740.63281,29.598,2819.20459,7.840,
1740.72437,29.598,2819.29614,7.840,
1740.81592,29.598,2819.38770,7.840,
1740.90735,29.598,2819.47925,7.840,
1740.99890,29.598,2819.57080,7.840,
1741.09045,29.598,2819.66235,7.840,
1741.18201,29.598,2819.75391,7.840,
1741.27344,29.598,2819.84546,7.840,
1741.36499,29.598,2819.93677,7.840,
1741.45654,29.598,2820.02832,7.840,
1741.54810,29.598,2820.11987,7.840,
1741.63953,29.598,2820.21143,7.840,
1741.73108,30.598,2820.30298,7.840,
1741.82263,29.598,2820.39453,8.840,
1741.91418,29.598,2820.48608,7.840,
1742.00562,30.598,2820.57739,7.840,
1742.09717,29.598,2820.66895,7.840,
1742.18872,29.598,2820.76050,7.840,
1742.28027,29.598,2820.85205,8.840,
1742.37170,29.598,2820.94360,7.840,
1742.46326,29.598,2821.03516,7.840,
1742.55481,29.598,2821.12671,7.840,
1742.64624,29.598,2821.21826,8.840,
1742.73779,29.598,2821.30957,8.840,
1742.82935,29.598,2821.40112,7.840,
1742.92090,29.598,2821.49268,8.840,
1743.01233,28.598,2821.58423,7.840,
1743.10388,29.598,2821.67578,7.840,
1743.19543,29.598,2821.76733,7.840,
1743.28699,29.598,2821.85889,8.840,
1743.37842,29.598,2821.95020,8.840,
1743.46997,30.598,2822.04175,7.840,
1743.56152,29.598,2822.13330,7.840,
1743.65308,29.598,2822.22485,7.840,
1743.74451,29.598,2822.31641,7.840,
1743.83606,29.598,2822.40796,7.840,
1743.92761,29.598,2822.49951,7.840,
1744.01917,29.598,2822.59106,7.840,
1744.11060,29.598,2822.68237,8.840,
1744.20215,29.598,2822.77393,7.840,
1744.29370,29.598,2822.86548,7.840,
1744.38513,29.598,2822.95703,8.840,
1744.47668,29.598,2823.04858,7.840,
1744.56824,29.598,2823.14014,8.840,
1744.65979,29.598,2823.23169,8.840,
1744.75122,29.598,2823.32324,8.840,
1744.84277,29.598,2823.41455,7.840,
1744.93433,30.598,2823.50610,7.840,
1745.02588,29.598,2823.59766,8.840,
1745.11731,29.598,2823.68921,7.840,
1745.20886,29.598,2823.78076,7.840,
1745.30042,29.598,2823.87231,7.840,
1745.39197,29.598,2823.96387,8.840,
1745.48340,29.598,2824.05518,8.840,
1745.57495,29.598,2824.14673,8.840,
1745.66650,29.598,2824.23828,8.840,
1745.75806,29.598,2824.32983,8.840,
1745.84949,29.598,2824.42139,7.840,
1745.94104,29.598,2824.51294,8.840,
1746.03259,29.598,2824.60449,8.840,
1746.12415,29.598,2824.69604,8.840,
1746.21558,29.598,2824.78735,7.840,
1746.30713,29.598,2824.87891,8.840,
1746.39868,29.598,2824.97046,8.840,
1746.49011,30.598,2825.06201,7.840,
1746.58167,29.598,2825.15356,7.840,
1746.67322,29.598,2825.24512,8.840,
1746.76477,29.598,2825.33667,8.840,
1746.85620,30.598,2825.42822,7.840,
1746.94775,29.598,2825.51953,7.840,
1747.03931,29.598,2825.61108,8.840,
1747.13086,29.598,2825.70264,7.840,
1747.22229,29.598,2825.79419,8.840,
1747.31384,29.598,2825.88574,8.840,
1747.40540,29.598,2825.97729,8.840,
1747.49695,29.598,2826.06885,8.840,
1747.58838,29.598,2826.16016,8.840,
1747.67993,29.598,2826.25171,8.840,
1747.77148,30.598,2826.34326,8.840,
1747.86304,30.598,2826.43481,8.840,
1747.95447,29.598,2826.52637,8.840,
1748.04602,29.598,2826.61792,8.840,
1748.13757,30.598,2826.70947,8.840,
1748.22900,30.598,2826.80103,8.840,
1748.32056,30.598,2826.89233,8.840,
1748.41211,29.598,2826.98389,7.840,
1748.50366,29.598,2827.07544,8.840,
1748.59509,29.598,2827.16699,8.840,
1748.68665,29.598,2827.25854,8.840,
1748.77820,29.598,2827.35010,7.840,
1748.86975,29.598,2827.44165,8.840,
1748.96118,29.598,2827.53296,8.840,
1749.05273,30.598,2827.62451,8.840,
1749.14429,29.598,2827.71606,8.840,
1749.23584,29.598,2827.80762,8.840,
1749.32727,30.598,2827.89917,8.840,
1749.41882,30.598,2827.99072,8.840,
1749.51038,29.598,2828.08228,8.840,
1749.60193,30.598,2828.17383,7.840,
1749.69336,30.598,2828.26514,8.840,
1749.78491,30.598,2828.35669,8.840,
1749.87646,30.598,2828.44824,8.840,
1749.96802,30.598,2828.53979,9.840,
1750.05945,30.598,2828.63135,8.840,
1750.15100,29.598,2828.72290,8.840,
1750.24255,29.598,2828.81445,8.840,
1750.33398,30.598,2828.90601,8.840,
1750.42554,30.598,2828.99731,8.840,
1750.51709,30.598,2829.08887,7.840,
1750.60864,30.598,2829.18042,7.840,
1750.70007,30.598,2829.27197,7.840,
1750.79163,30.598,2829.36353,7.840,
1750.88318,30.598,2829.45508,7.840,
1750.97473,30.598,2829.54663,7.840,
1751.06616,29.598,2829.63794,7.840,
1751.15771,30.598,2829.72949,7.840,
1751.24927,30.598,2829.82104,8.840,
1751.34082,30.598,2829.91260,7.840,
1751.43225,30.598,2830.00415,8.840,
1751.52380,30.598,2830.09570,8.840,
1751.61536,29.598,2830.18726,8.840,
1751.70691,29.598,2830.27881,8.840,
1751.79834,30.598,2830.37012,8.840,
1751.88989,29.598,2830.46167,8.840,
1751.98145,29.598,2830.55322,8.840,
1752.07288,29.598,2830.64478,8.840,
1752.16443,29.598,2830.73633,8.840,
1752.25598,30.598,2830.82788,8.840,
1752.34753,30.598,2830.91943,8.840,
1752.43896,30.598,2831.01099,8.840,
1752.53052,29.598,2831.10229,7.840,
1752.62207,30.598,2831.19385,7.840,
1752.71362,30.598,2831.28540,7.840,
1752.80505,29.598,2831.37695,8.840,
1752.89661,30.598,2831.46851,9.840,
1752.98816,30.598,2831.56006,8.840,
1753.07971,30.598,2831.65161,7.840,
1753.17114,30.598,2831.74292,8.840,
1753.26270,30.598,2831.83447,8.840,
1753.35425,30.598,2831.92603,8.840,
1753.44580,29.598,2832.01758,8.840,
1753.53723,30.598,2832.10913,8.840,
1753.62878,30.598,2832.20068,8.840,
1753.72034,30.598,2832.29224,8.840,
1753.81177,30.598,2832.38379,8.840,
1753.90332,30.598,2832.47510,8.840,
1753.99487,30.598,2832.56665,8.840,
1754.08643,29.598,2832.65820,8.840,
1754.17786,30.598,2832.74976,8.840,
1754.26941,30.598,2832.84131,8.840,
1754.36096,30.598,2832.93286,10.840,
1754.45251,29.598,2833.02441,8.840,
1754.54395,30.598,2833.11597,8.840,
1754.63550,29.598,2833.20728,9.840,
1754.72705,30.598,2833.29883,8.840,
1754.81860,30.598,2833.39038,8.840,
1754.91003,30.598,2833.48193,8.840,
1755.00159,29.598,2833.57349,9.840,
1755.09314,30.598,2833.66504,8.840,
1755.18469,30.598,2833.75659,9.840,
1755.27612,30.598,2833.84790,8.840,
1755.36768,30.598,2833.93945,8.840,
1755.45923,30.598,2834.03101,8.840,
1755.55078,30.598,2834.12256,8.840,
1755.64221,30.598,2834.21411,8.840,
1755.73376,30.598,2834.30566,8.840,
1755.82532,31.598,2834.39722,9.840,
1755.91675,30.598,2834.48877,8.840,
1756.00830,31.598,2834.58008,8.840,
1756.09985,30.598,2834.67163,8.840,
1756.19141,30.598,2834.76318,9.840,
1756.28284,30.598,2834.85474,8.840,
1756.37439,30.598,2834.94629,8.840,
1756.46594,30.598,2835.03784,9.840,
1756.55750,30.598,2835.12939,8.840,
1756.64893,30.598,2835.22070,8.840,
1756.74048,30.598,2835.31226,8.840,
1756.83203,30.598,2835.40381,8.840,
1756.92358,30.598,2835.49536,8.840,
1757.01501,31.598,2835.58691,8.840,
1757.10657,30.598,2835.67847,8.840,
1757.19812,30.598,2835.77002,8.840,
1757.28967,31.598,2835.86157,9.840,
1757.38110,30.598,2835.95288,8.840,
1757.47266,29.598,2836.04443,8.840,
1757.56421,30.598,2836.13599,8.840,
1757.65564,29.598,2836.22754,8.840,
1757.74719,29.598,2836.31909,8.840,
1757.83875,29.598,2836.41064,8.840,
1757.93030,29.598,2836.50220,8.840,
1758.02173,29.598,2836.59375,8.840,
1758.11328,30.598,2836.68506,8.840,
1758.20483,29.598,2836.77661,8.840,
1758.29639,29.598,2836.86816,8.840,
1758.38782,29.598,2836.95972,8.840,
1758.47937,30.598,2837.05127,8.840,
1758.57092,30.598,2837.14282,8.840,
1758.66248,30.598,2837.23438,8.840,
1758.75391,30.598,2837.32568,9.840,
1758.84546,30.598,2837.41724,9.840,
1758.93701,30.598,2837.50879,9.840,
1759.02856,30.598,2837.60034,8.840,
1759.12000,31.598,2837.69189,8.840,
1759.21155,31.598,2837.78345,9.840,
1759.30310,30.598,2837.87500,9.840,
1759.39465,30.598,2837.96655,8.840,
1759.48608,30.598,2838.05786,9.840,
1759.57764,31.598,2838.14941,8.840,
1759.66919,31.598,2838.24097,8.840,
1759.76062,30.598,2838.33252,8.840,
1759.85217,30.598,2838.42407,8.840,
1759.94373,30.598,2838.51563,8.840,
1760.03528,30.598,2838.60718,8.840,
1760.12671,31.598,2838.69873,8.840,
1760.21826,30.598,2838.79004,9.840,
1760.30981,31.598,2838.88159,8.840,
1760.40137,30.598,2838.97314,9.840,
1760.49280,30.598,2839.06470,8.840,
1760.58435,30.598,2839.15625,8.840,
1760.67590,31.598,2839.24780,9.840,
1760.76746,30.598,2839.33936,9.840,
1760.85889,30.598,2839.43066,9.840,
1760.95044,30.598,2839.52222,9.840,
1761.04199,31.598,2839.61377,8.840,
1761.13354,30.598,2839.70532,8.840,
1761.22498,30.598,2839.79688,8.840,
1761.31653,31.598,2839.88843,8.840,
1761.40808,30.598,2839.97998,9.840,
1761.49951,30.598,2840.07153,8.840,
1761.59106,30.598,2840.16284,8.840,
1761.68262,30.598,2840.25439,10.840,
1761.77417,30.598,2840.34595,9.840,
1761.86560,31.598,2840.43750,8.840,
1761.95715,30.598,2840.52905,9.840,
1762.04871,30.598,2840.62061,8.840,
1762.14026,30.598,2840.71216,9.840,
1762.23169,30.598,2840.80347,8.840,
1762.32324,30.598,2840.89502,8.840,
1762.41479,30.598,2840.98657,8.840,
1762.50635,31.598,2841.07813,8.840,
1762.59778,30.598,2841.16968,8.840,
1762.68933,31.598,2841.26123,8.840,
1762.78088,31.598,2841.35278,8.840,
1762.87244,31.598,2841.44434,8.840,
1762.96387,30.598,2841.53564,8.840,
1763.05542,31.598,2841.62720,8.840,
1763.14697,30.598,2841.71875,9.840,
1763.23840,30.598,2841.81030,9.840,
1763.32996,30.598,2841.90186,8.840,
1763.42151,30.598,2841.99341,8.840,
1763.51306,30.598,2842.08496,8.840,
1763.60449,30.598,2842.17651,8.840,
1763.69604,30.598,2842.26782,9.840,
1763.78760,30.598,2842.35938,9.840,
1763.87915,30.598,2842.45093,9.840,
1763.97058,31.598,2842.54248,8.840,
1764.06213,30.598,2842.63403,8.840,
1764.15369,31.598,2842.72559,8.840,
1764.24524,31.598,2842.81714,7.840,
1764.33667,31.598,2842.90845,9.840,
1764.42822,31.598,2843.00000,8.840,
1764.51978,30.598,2843.09155,8.840,
1764.61133,30.598,2843.18311,8.840,
1764.70276,30.598,2843.27466,8.840,
1764.79431,31.598,2843.36621,8.840,
1764.88586,31.598,2843.45776,8.840,
1764.97742,30.598,2843.54932,8.840,
1765.06885,31.598,2843.64063,8.840,
1765.16040,31.598,2843.73218,8.840,
1765.25195,31.598,2843.82373,8.840,
1765.34338,31.598,2843.91528,9.840,
1765.43494,31.598,2844.00684,8.840,
1765.52649,31.598,2844.09839,8.840,
1765.61804,31.598,2844.18994,8.840,
1765.70947,31.598,2844.28149,8.840,
1765.80103,31.598,2844.37280,8.840,
1765.89258,31.598,2844.46436,8.840,
1765.98413,31.598,2844.55591,8.840,
1766.07556,31.598,2844.64746,9.840,
1766.16711,31.598,2844.73901,8.840,
1766.25867,31.598,2844.83057,9.840,
1766.35022,31.598,2844.92212,8.840,
1766.44165,31.598,2845.01343,8.840,
1766.53320,31.598,2845.10498,8.840,
1766.62476,31.598,2845.19653,8.840,
1766.71631,31.598,2845.28809,9.840,
1766.80774,31.598,2845.37964,8.840,
1766.89929,31.598,2845.47119,9.840,
1766.99084,31.598,2845.56274,8.840,
1767.08228,31.598,2845.65430,9.840,
1767.17383,31.598,2845.74561,9.840,
1767.26538,31.598,2845.83716,9.840,
1767.35693,31.598,2845.92871,8.840,
1767.44836,31.598,2846.02026,8.840,
1767.53992,31.598,2846.11182,9.840,
1767.63147,31.598,2846.20337,8.840,
1767.72302,30.598,2846.29492,9.840,
1767.81445,31.598,2846.38623,9.840,
1767.90601,31.598,2846.47778,9.840,
1767.99756,31.598,2846.56934,9.840,
1768.08911,31.598,2846.66089,9.840,
1768.18054,31.598,2846.75244,9.840,
1768.27209,31.598,2846.84399,9.840,
1768.36365,32.598,2846.93555,8.840,
1768.45520,31.598,2847.02710,9.840,
1768.54663,31.598,2847.11841,8.840,
1768.63818,31.598,2847.20996,9.840,
1768.72974,30.598,2847.30151,8.840,
1768.82129,31.598,2847.39307,9.840,
1768.91272,31.598,2847.48462,9.840,
1769.00427,31.598,2847.57617,9.840,
1769.09583,31.598,2847.66772,9.840,
1769.18726,31.598,2847.75928,8.840,
1769.27881,31.598,2847.85059,9.840,
1769.37036,31.598,2847.94214,9.840,
1769.46191,31.598,2848.03369,8.840,
1769.55334,31.598,2848.12524,9.840,
1769.64490,31.598,2848.21680,9.840,
1769.73645,31.598,2848.30835,9.840,
1769.82800,31.598,2848.39990,8.840,
1769.91943,31.598,2848.49121,8.840,
1770.01099,31.598,2848.58276,8.840,
1770.10254,30.598,2848.67432,8.840,
1770.19409,31.598,2848.76587,9.840,
1770.28552,31.598,2848.85742,9.840,
1770.37708,31.598,2848.94897,9.840,
1770.46863,31.598,2849.04053,9.840,
1770.56018,30.598,2849.13208,9.840,
1770.65161,31.598,2849.22339,9.840,
1770.74316,31.598,2849.31494,9.840,
1770.83472,31.598,2849.40649,9.840,
1770.92615,31.598,2849.49805,9.840,
1771.01770,31.598,2849.58960,9.840,
1771.10925,31.598,2849.68115,9.840,
1771.20081,31.598,2849.77271,9.840,
1771.29224,31.598,2849.86426,8.840,
1771.38379,31.598,2849.95557,8.840,
1771.47534,31.598,2850.04712,8.840,
1771.56689,31.598,2850.13867,8.840,
1771.65833,32.598,2850.23022,9.840,
1771.74988,31.598,2850.32178,9.840,
1771.84143,31.598,2850.41333,9.840,
1771.93298,31.598,2850.50488,9.840,
1772.02441,31.598,2850.59619,9.840,
1772.11597,32.598,2850.68774,9.840,
1772.20752,31.598,2850.77930,9.840,
1772.29907,31.598,2850.87085,9.840,
1772.39050,31.598,2850.96240,9.840,
1772.48206,31.598,2851.05396,9.840,
1772.57361,31.598,2851.14551,9.840,
1772.66504,31.598,2851.23706,9.840,
1772.75659,31.598,2851.32837,8.840,
1772.84814,31.598,2851.41992,9.840,
1772.93970,31.598,2851.51147,8.840,
1773.03113,31.598,2851.60303,9.840,
1773.12268,31.598,2851.69458,9.840,
1773.21423,31.598,2851.78613,9.840,
1773.30579,31.598,2851.87769,9.840,
1773.39722,31.598,2851.96924,9.840,
1773.48877,31.598,2852.06055,8.840,
1773.58032,31.598,2852.15210,8.840,
1773.67188,31.598,2852.24365,8.840,
1773.76331,31.598,2852.33521,7.840,
1773.85486,31.598,2852.42676,7.840,
1773.94641,31.598,2852.51831,7.840,
1774.03796,32.598,2852.60986,7.840,
1774.12939,32.598,2852.70117,7.840,
1774.22095,32.598,2852.79272,7.840,
1774.31250,31.598,2852.88428,7.840,
1774.40405,31.598,2852.97583,7.840,
1774.49548,32.598,2853.06738,7.840,
1774.58704,31.598,2853.15894,8.840,
1774.67859,31.598,2853.25049,8.840,
1774.77002,31.598,2853.34204,8.840,
1774.86157,31.598,2853.43335,9.840,
1774.95313,32.598,2853.52490,8.840,
1775.04468,31.598,2853.61646,8.840,
1775.13611,32.598,2853.70801,8.840,
1775.22766,32.598,2853.79956,9.840,
1775.31921,31.598,2853.89111,8.840,
1775.41077,31.598,2853.98267,9.840,
1775.50220,31.598,2854.07397,8.840,
1775.59375,32.598,2854.16553,8.840,
1775.68530,32.598,2854.25708,8.840,
1775.77686,31.598,2854.34863,8.840,
1775.86829,32.598,2854.44019,9.840,
1775.95984,32.598,2854.53174,9.840,
1776.05139,32.598,2854.62329,9.840,
1776.14294,31.598,2854.71484,9.840,
1776.23438,32.598,2854.80615,8.840,
1776.32593,32.598,2854.89771,9.840,
1776.41748,32.598,2854.98926,9.840,
1776.50891,32.598,2855.08081,9.840,
1776.60046,32.598,2855.17236,8.840,
1776.69202,32.598,2855.26392,9.840,
1776.78357,32.598,2855.35547,9.840,
1776.87500,32.598,2855.44702,9.840,
1776.96655,32.598,2855.53833,9.840,
1777.05811,32.598,2855.62988,9.840,
1777.14966,32.598,2855.72144,8.840,
1777.24109,32.598,2855.81299,9.840,
1777.33264,32.598,2855.90454,9.840,
1777.42419,32.598,2855.99609,9.840,
1777.51575,32.598,2856.08765,8.840,
1777.60718,32.598,2856.17896,8.840,
1777.69873,32.598,2856.27051,9.840,
1777.79028,32.598,2856.36206,10.840,
1777.88184,33.598,2856.45361,9.840,
1777.97327,32.598,2856.54517,9.840,
1778.06482,32.598,2856.63672,9.840,
1778.15637,32.598,2856.72827,9.840,
1778.24792,32.598,2856.81982,9.840,
1778.33936,33.598,2856.91113,9.840,
1778.43091,32.598,2857.00269,9.840,
1778.52246,32.598,2857.09424,8.840,
1778.61389,33.598,2857.18579,9.840,
1778.70544,32.598,2857.27734,8.840,
1778.79700,32.598,2857.36890,9.840,
1778.88855,32.598,2857.46045,9.840,
1778.97998,32.598,2857.55200,9.840,
1779.07153,32.598,2857.64331,9.840,
1779.16309,32.598,2857.73486,9.840,
1779.25464,32.598,2857.82642,9.840,
1779.34607,32.598,2857.91797,9.840,
1779.43762,32.598,2858.00952,9.840,
1779.52917,32.598,2858.10107,9.840,
1779.62073,32.598,2858.19263,9.840,
1779.71216,32.598,2858.28394,9.840,
1779.80371,32.598,2858.37549,9.840,
1779.89526,32.598,2858.46704,9.840,
1779.98682,32.598,2858.55859,9.840,
1780.07825,32.598,2858.65015,9.840,
1780.16980,31.598,2858.74170,8.840,
1780.26135,32.598,2858.83325,9.840,
1780.35278,32.598,2858.92480,9.840,
1780.44434,32.598,2859.01611,9.840,
1780.53589,32.598,2859.10767,9.840,
1780.62744,32.598,2859.19922,8.840,
1780.71887,32.598,2859.29077,9.840,
1780.81042,32.598,2859.38232,9.840,
1780.90198,31.598,2859.47388,8.840,
1780.99353,31.598,2859.56543,9.840,
1781.08496,31.598,2859.65674,9.840,
1781.17651,31.598,2859.74829,9.840,
1781.26807,32.598,2859.83984,9.840,
1781.35962,32.598,2859.93140,9.840,
1781.45105,32.598,2860.02295,8.840,
1781.54260,32.598,2860.11450,9.840,
1781.63416,32.598,2860.20605,9.840,
1781.72571,32.598,2860.29761,9.840,
1781.81714,32.598,2860.38892,9.840,
1781.90869,32.598,2860.48047,9.840,
1782.00024,32.598,2860.57202,9.840,
1782.09167,33.598,2860.66357,9.840,
1782.18323,33.598,2860.75513,10.840,
1782.27478,32.598,2860.84668,10.840,
1782.36633,33.598,2860.93823,9.840,
1782.45776,33.598,2861.02979,9.840,
1782.54932,32.598,2861.12109,10.840,
1782.64087,33.598,2861.21265,9.840,
1782.73242,33.598,2861.30420,9.840,
1782.82385,33.598,2861.39575,9.840,
1782.91541,32.598,2861.48730,9.840,
1783.00696,33.598,2861.57886,9.840,
1783.09851,33.598,2861.67041,9.840,
1783.18994,33.598,2861.76172,9.840,
1783.28149,33.598,2861.85327,9.840,
1783.37305,33.598,2861.94482,8.840,
1783.46460,32.598,2862.03638,9.840,
1783.55603,32.598,2862.12793,9.840,
1783.64758,32.598,2862.21948,9.840,
1783.73914,32.598,2862.31104,9.840,
1783.83069,32.598,2862.40259,9.840,
1783.92212,33.598,2862.49390,9.840,
1784.01367,32.598,2862.58545,9.840,
1784.10522,32.598,2862.67700,9.840,
1784.19666,33.598,2862.76855,9.840,
1784.28821,33.598,2862.86011,9.840,
1784.37976,32.598,2862.95166,9.840,
1784.47131,33.598,2863.04321,9.840,
1784.56274,33.598,2863.13477,9.840,
1784.65430,32.598,2863.22607,9.840,
1784.74585,33.598,2863.31763,9.840,
1784.83740,33.598,2863.40918,9.840,
1784.92883,32.598,2863.50073,9.840,
1785.02039,32.598,2863.59229,10.840,
1785.11194,33.598,2863.68384,10.840,
1785.20349,33.598,2863.77539,9.840,
1785.29492,32.598,2863.86670,10.840,
1785.38647,32.598,2863.95825,9.840,
1785.47803,33.598,2864.04980,9.840,
1785.56958,33.598,2864.14136,9.840,
1785.66101,32.598,2864.23291,9.840,
1785.75256,32.598,2864.32446,9.840,
1785.84412,33.598,2864.41602,9.840,
1785.93555,33.598,2864.50757,10.840,
1786.02710,33.598,2864.59888,9.840,
1786.11865,33.598,2864.69043,9.840,
1786.21021,33.598,2864.78198,9.840,
1786.30164,33.598,2864.87354,10.840,
1786.39319,33.598,2864.96509,9.840,
1786.48474,33.598,2865.05664,10.840,
1786.57629,33.598,2865.14819,11.840,
1786.66772,33.598,2865.23950,10.840,
1786.75928,33.598,2865.33105,10.840,
1786.85083,33.598,2865.42261,10.840,
1786.94238,33.598,2865.51416,9.840,
1787.03381,33.598,2865.60571,9.840,
1787.12537,33.598,2865.69727,10.840,
1787.21692,32.598,2865.78882,10.840,
1787.30847,33.598,2865.88037,10.840,
1787.39990,33.598,2865.97168,10.840,
1787.49146,33.598,2866.06323,9.840,
1787.58301,33.598,2866.15479,10.840,
1787.67456,33.598,2866.24634,10.840,
1787.76599,33.598,2866.33789,10.840,
1787.85754,33.598,2866.42944,9.840,
1787.94910,34.598,2866.52100,9.840,
1788.04053,33.598,2866.61255,10.840,
1788.13208,33.598,2866.70386,10.840,
1788.22363,33.598,2866.79541,9.840,
1788.31519,33.598,2866.88696,10.840,
1788.40662,33.598,2866.97852,10.840,
1788.49817,33.598,2867.07007,10.840,
1788.58972,33.598,2867.16162,10.840,
1788.68127,33.598,2867.25317,10.840,
1788.77271,33.598,2867.34448,10.840,
1788.86426,34.598,2867.43604,9.840,
1788.95581,33.598,2867.52759,10.840,
1789.04736,33.598,2867.61914,10.840,
1789.13879,33.598,2867.71069,9.840,
1789.23035,33.598,2867.80225,9.840,
1789.32190,33.598,2867.89380,10.840,
1789.41345,33.598,2867.98535,9.840,
1789.50488,33.598,2868.07666,10.840,
1789.59644,33.598,2868.16821,9.840,
1789.68799,33.598,2868.25977,9.840,
1789.77942,33.598,2868.35132,9.840,
1789.87097,33.598,2868.44287,10.840,
1789.96252,33.598,2868.53442,9.840,
1790.05408,34.598,2868.62598,10.840,
1790.14551,33.598,2868.71753,9.840,
1790.23706,33.598,2868.80884,10.840,
1790.32861,33.598,2868.90039,10.840,
1790.42017,33.598,2868.99194,9.840,
1790.51160,33.598,2869.08350,10.840,
1790.60315,33.598,2869.17505,9.840,
1790.69470,34.598,2869.26660,9.840,
1790.78625,33.598,2869.35815,10.840,
1790.87769,33.598,2869.44946,10.840,
1790.96924,33.598,2869.54102,10.840,
1791.06079,34.598,2869.63257,10.840,
1791.15234,33.598,2869.72412,10.840,
1791.24377,33.598,2869.81567,10.840,
1791.33533,33.598,2869.90723,10.840,
1791.42688,33.598,2869.99878,10.840,
1791.51831,33.598,2870.09033,10.840,
1791.60986,33.598,2870.18164,10.840,
1791.70142,33.598,2870.27319,10.840,
1791.79297,34.598,2870.36475,10.840,
1791.88440,34.598,2870.45630,10.840,
1791.97595,33.598,2870.54785,10.840,
1792.06750,33.598,2870.63940,10.840,
1792.15906,33.598,2870.73096,10.840,
1792.25049,34.598,2870.82251,9.840,
1792.34204,33.598,2870.91382,10.840,
1792.43359,33.598,2871.00537,10.840,
1792.52515,33.598,2871.09692,10.840,
1792.61658,33.598,2871.18848,10.840,
1792.70813,33.598,2871.28003,10.840,
1792.79968,33.598,2871.37158,9.840,
1792.89124,34.598,2871.46313,10.840,
1792.98267,33.598,2871.55444,10.840,
1793.07422,33.598,2871.64600,10.840,
1793.16577,33.598,2871.73755,10.840,
1793.25732,34.598,2871.82910,10.840,
1793.34875,34.598,2871.92065,10.840,
1793.44031,33.598,2872.01221,10.840,
1793.53186,33.598,2872.10376,10.840,
1793.62329,33.598,2872.19531,10.840,
1793.71484,33.598,2872.28662,10.840,
1793.80640,33.598,2872.37817,10.840,
1793.89795,33.598,2872.46973,10.840,
1793.98938,33.598,2872.56128,10.840,
1794.08093,33.598,2872.65283,10.840,
1794.17249,33.598,2872.74438,10.840,
1794.26404,33.598,2872.83594,10.840,
1794.35547,33.598,2872.92725,9.840,
1794.44702,33.598,2873.01880,9.840,
1794.53857,33.598,2873.11035,10.840,
1794.63013,33.598,2873.20190,9.840,
1794.72156,34.598,2873.29346,10.840,
1794.81311,33.598,2873.38501,10.840,
1794.90466,33.598,2873.47656,10.840,
1794.99622,33.598,2873.56812,10.840,
1795.08765,33.598,2873.65942,9.840,
1795.17920,33.598,2873.75098,10.840,
1795.27075,33.598,2873.84253,10.840,
1795.36218,33.598,2873.93408,11.840,
1795.45374,34.598,2874.02563,10.840,
1795.54529,33.598,2874.11719,10.840,
1795.63684,34.598,2874.20874,10.840,
1795.72827,33.598,2874.30029,10.840,
1795.81982,33.598,2874.39160,11.840,
1795.91138,33.598,2874.48315,10.840,
1796.00293,34.598,2874.57471,11.840,
1796.09436,33.598,2874.66626,10.840,
1796.18591,34.598,2874.75781,10.840,
1796.27747,33.598,2874.84937,10.840,
1796.36902,33.598,2874.94092,10.840,
1796.46045,33.598,2875.03223,10.840,
1796.55200,34.598,2875.12378,10.840,
1796.64355,33.598,2875.21533,10.840,
1796.73511,33.598,2875.30688,10.840,
1796.82654,34.598,2875.39844,10.840,
1796.91809,33.598,2875.48999,10.840,
1797.00964,33.598,2875.58154,11.840,
1797.10120,33.598,2875.67310,11.840,
1797.19263,34.598,2875.76440,10.840,
1797.28418,33.598,2875.85596,10.840,
1797.37573,34.598,2875.94751,10.840,
1797.46716,34.598,2876.03906,10.840,
1797.55872,34.598,2876.13062,11.840,
1797.65027,34.598,2876.22217,10.840,
1797.74182,33.598,2876.31372,11.840,
1797.83325,33.598,2876.40527,10.840,
1797.92480,34.598,2876.49658,10.840,
1798.01636,34.598,2876.58813,10.840,
1798.10791,34.598,2876.67969,10.840,
1798.19934,34.598,2876.77124,11.840,
1798.29089,34.598,2876.86279,11.840,
1798.38245,34.598,2876.95435,10.840,
1798.47400,33.598,2877.04590,11.840,
1798.56543,33.598,2877.13721,11.840,
1798.65698,34.598,2877.22876,10.840,
1798.74854,34.598,2877.32031,11.840,
1798.84009,34.598,2877.41187,11.840,
1798.93152,34.598,2877.50342,10.840,
1799.02307,34.598,2877.59497,11.840,
1799.11462,34.598,2877.68652,11.840,
1799.20605,34.598,2877.77808,10.840,
1799.29761,34.598,2877.86938,10.840,
1799.38916,34.598,2877.96094,11.840,
1799.48071,34.598,2878.05249,11.840,
1799.57214,34.598,2878.14404,10.840,
1799.66370,34.598,2878.23560,10.840,
1799.75525,33.598,2878.32715,12.840,
1799.84680,34.598,2878.41870,11.840,
1799.93823,34.598,2878.51001,11.840,
1800.02979,34.598,2878.60156,10.840,
1800.12134,33.598,2878.69312,11.840,
1800.21289,34.598,2878.78467,11.840,
1800.30432,34.598,2878.87622,11.840,
1800.39587,33.598,2878.96777,11.840,
1800.48743,33.598,2879.05933,11.840,
1800.57898,34.598,2879.15088,11.840,
1800.67041,33.598,2879.24219,11.840,
1800.76196,34.598,2879.33374,11.840,
1800.85352,34.598,2879.42529,11.840,
1800.94495,34.598,2879.51685,11.840,
1801.03650,34.598,2879.60840,11.840,
1801.12805,35.598,2879.69995,11.840,
1801.21960,34.598,2879.79150,11.840,
1801.31104,34.598,2879.88306,11.840,
1801.40259,34.598,2879.97437,10.840,
1801.49414,34.598,2880.06592,11.840,
1801.58569,34.598,2880.15747,11.840,
1801.67712,34.598,2880.24902,10.840,
1801.76868,34.598,2880.34058,11.840,
1801.86023,34.598,2880.43213,11.840,
1801.95178,34.598,2880.52368,11.840,
1802.04321,35.598,2880.61499,11.840,
1802.13477,34.598,2880.70654,11.840,
1802.22632,34.598,2880.79810,11.840,
1802.31787,34.598,2880.88965,10.840,
1802.40930,34.598,2880.98120,11.840,
1802.50085,34.598,2881.07275,11.840,
1802.59241,34.598,2881.16431,10.840,
1802.68396,34.598,2881.25586,11.840,
1802.77539,34.598,2881.34717,11.840,
1802.86694,34.598,2881.43872,11.840,
1802.95850,34.598,2881.53027,11.840,
1803.04993,34.598,2881.62183,11.840,
1803.14148,34.598,2881.71338,11.840,
1803.23303,33.598,2881.80493,11.840,
1803.32458,33.598,2881.89648,11.840,
1803.41602,33.598,2881.98804,11.840,
1803.50757,33.598,2882.07935,11.840,
1803.59912,33.598,2882.17090,11.840,
1803.69067,33.598,2882.26245,11.840,
1803.78210,33.598,2882.35400,11.840,
1803.87366,33.598,2882.44556,11.840,
1803.96521,33.598,2882.53711,11.840,
1804.05676,33.598,2882.62866,11.840,
1804.14819,33.598,2882.71997,11.840,
1804.23975,33.598,2882.81152,11.840,
1804.33130,33.598,2882.90308,11.840,
1804.42285,33.598,2882.99463,11.840,
1804.51428,33.598,2883.08618,11.840,
1804.60583,33.598,2883.17773,11.840,
1804.69739,34.598,2883.26929,11.840,
1804.78882,34.598,2883.36084,11.840,
1804.88037,33.598,2883.45215,11.840,
1804.97192,34.598,2883.54370,11.840,
1805.06348,34.598,2883.63525,11.840,
1805.15491,34.598,2883.72681,11.840,
1805.24646,34.598,2883.81836,11.840,
1805.33801,34.598,2883.90991,11.840,
1805.42957,34.598,2884.00146,11.840,
1805.52100,34.598,2884.09277,11.840,
1805.61255,34.598,2884.18433,11.840,
1805.70410,34.598,2884.27588,11.840,
1805.79565,34.598,2884.36743,11.840,
1805.88708,34.598,2884.45898,11.840,
1805.97864,34.598,2884.55054,11.840,
1806.07019,34.598,2884.64209,11.840,
1806.16174,34.598,2884.73364,11.840,
1806.25317,34.598,2884.82495,11.840,
1806.34473,34.598,2884.91650,11.840,
1806.43628,34.598,2885.00806,11.840,
1806.52783,34.598,2885.09961,11.840,
1806.61926,34.598,2885.19116,11.840,
1806.71082,34.598,2885.28271,11.840,
1806.80237,34.598,2885.37427,11.840,
1806.89380,34.598,2885.46582,10.840,
1806.98535,35.598,2885.55713,10.840,
1807.07690,34.598,2885.64868,12.840,
1807.16846,34.598,2885.74023,11.840,
1807.25989,34.598,2885.83179,11.840,
1807.35144,34.598,2885.92334,11.840,
1807.44299,34.598,2886.01489,11.840,
1807.53455,34.598,2886.10645,11.840,
1807.62598,34.598,2886.19775,11.840,
1807.71753,34.598,2886.28931,11.840,
1807.80908,34.598,2886.38086,11.840,
1807.90063,35.598,2886.47241,11.840,
1807.99207,35.598,2886.56396,11.840,
1808.08362,34.598,2886.65552,11.840,
1808.17517,34.598,2886.74707,11.840,
1808.26672,35.598,2886.83862,11.840,
1808.35815,34.598,2886.92993,11.840,
1808.44971,35.598,2887.02148,11.840,
1808.54126,35.598,2887.11304,11.840,
1808.63269,34.598,2887.20459,11.840,
1808.72424,34.598,2887.29614,11.840,
1808.81580,34.598,2887.38770,11.840,
1808.90735,34.598,2887.47925,11.840,
1808.99878,34.598,2887.57080,11.840,
1809.09033,34.598,2887.66211,11.840,
1809.18188,34.598,2887.75366,11.840,
1809.27344,34.598,2887.84521,11.840,
1809.36487,35.598,2887.93677,11.840,
1809.45642,34.598,2888.02832,11.840,
1809.54797,34.598,2888.11987,11.840,
1809.63953,34.598,2888.21143,11.840,
1809.73096,34.598,2888.30273,11.840,
1809.82251,35.598,2888.39429,12.840,
1809.91406,35.598,2888.48584,12.840,
1810.00562,35.598,2888.57739,11.840,
1810.09705,35.598,2888.66895,11.840,
1810.18860,34.598,2888.76050,11.840,
1810.28015,35.598,2888.85205,11.840,
1810.37158,35.598,2888.94360,11.840,
1810.46313,34.598,2889.03491,12.840,
1810.55469,35.598,2889.12646,12.840,
1810.64624,34.598,2889.21802,11.840,
1810.73767,35.598,2889.30957,11.840,
1810.82922,35.598,2889.40112,12.840,
1810.92078,35.598,2889.49268,12.840,
1811.01233,35.598,2889.58423,12.840,
1811.10376,35.598,2889.67578,11.840,
1811.19531,35.598,2889.76709,11.840,
1811.28687,34.598,2889.85864,12.840,
1811.37842,34.598,2889.95020,13.840,
1811.46985,35.598,2890.04175,13.840,
1811.56140,34.598,2890.13330,12.840,
1811.65295,34.598,2890.22485,13.840,
1811.74451,34.598,2890.31641,12.840,
1811.83594,35.598,2890.40771,12.840,
1811.92749,34.598,2890.49927,13.840,
1812.01904,35.598,2890.59082,12.840,
1812.11060,34.598,2890.68237,12.840,
1812.20203,34.598,2890.77393,12.840,
1812.29358,35.598,2890.86548,12.840,
1812.38513,34.598,2890.95703,12.840,
1812.47656,35.598,2891.04858,12.840,
1812.56812,34.598,2891.13989,12.840,
1812.65967,34.598,2891.23145,12.840,
1812.75122,34.598,2891.32300,11.840,
1812.84265,35.598,2891.41455,12.840,
1812.93420,35.598,2891.50610,12.840,
1813.02576,35.598,2891.59766,12.840,
1813.11731,35.598,2891.68921,12.840,
1813.20874,35.598,2891.78052,12.840,
1813.30029,34.598,2891.87207,12.840,
1813.39185,35.598,2891.96362,12.840,
1813.48340,34.598,2892.05518,12.840,
1813.57483,34.598,2892.14673,12.840,
1813.66638,35.598,2892.23828,12.840,
1813.75793,35.598,2892.32983,11.840,
1813.84949,34.598,2892.42139,11.840,
1813.94092,35.598,2892.51270,10.840,
1814.03247,35.598,2892.60425,10.840,
1814.12402,35.598,2892.69580,10.840,
1814.21545,35.598,2892.78735,10.840,
1814.30701,35.598,2892.87891,10.840,
1814.39856,35.598,2892.97046,11.840,
1814.49011,35.598,2893.06201,11.840,
1814.58154,35.598,2893.15356,10.840,
1814.67310,35.598,2893.24487,10.840,
1814.76465,35.598,2893.33643,11.840,
1814.85620,35.598,2893.42798,11.840,
1814.94763,35.598,2893.51953,11.840,
1815.03918,35.598,2893.61108,12.840,
1815.13074,35.598,2893.70264,11.840,
1815.22229,36.598,2893.79419,11.840,
1815.31372,35.598,2893.88550,12.840,
1815.40527,35.598,2893.97705,11.840,
1815.49683,35.598,2894.06860,12.840,
1815.58838,35.598,2894.16016,11.840,
1815.67981,35.598,2894.25171,12.840,
1815.77136,35.598,2894.34326,12.840,
1815.86292,35.598,2894.43481,12.840,
1815.95435,35.598,2894.52637,12.840,
1816.04590,35.598,2894.61768,12.840,
1816.13745,35.598,2894.70923,12.840,
1816.22900,35.598,2894.80078,12.840,
1816.32043,35.598,2894.89233,12.840,
1816.41199,35.598,2894.98389,12.840,
1816.50354,35.598,2895.07544,12.840,
1816.59509,35.598,2895.16699,12.840,
1816.68652,36.598,2895.25854,12.840,
1816.77808,35.598,2895.34985,12.840,
1816.86963,35.598,2895.44141,12.840,
1816.96118,35.598,2895.53296,12.840,
1817.05261,35.598,2895.62451,12.840,
1817.14417,36.598,2895.71606,12.840,
1817.23572,36.598,2895.80762,12.840,
1817.32727,35.598,2895.89917,12.840,
1817.41870,35.598,2895.99048,12.840,
1817.51025,35.598,2896.08203,12.840,
1817.60181,35.598,2896.17358,12.840,
1817.69336,36.598,2896.26514,12.840,
1817.78479,35.598,2896.35669,12.840,
1817.87634,35.598,2896.44824,12.840,
1817.96790,35.598,2896.53979,12.840,
1818.05933,35.598,2896.63135,12.840,
1818.15088,35.598,2896.72266,12.840,
1818.24243,36.598,2896.81421,12.840,
1818.33398,35.598,2896.90576,12.840,
1818.42542,35.598,2896.99731,13.840,
1818.51697,35.598,2897.08887,11.840,
1818.60852,36.598,2897.18042,12.840,
1818.70007,35.598,2897.27197,12.840,
1818.79150,35.598,2897.36328,13.840,
1818.88306,36.598,2897.45483,12.840,
1818.97461,35.598,2897.54639,12.840,
1819.06616,35.598,2897.63794,12.840,
1819.15759,35.598,2897.72949,12.840,
1819.24915,35.598,2897.82104,12.840,
1819.34070,35.598,2897.91260,12.840,
1819.43225,36.598,2898.00415,12.840,
1819.52368,35.598,2898.09546,12.840,
1819.61523,36.598,2898.18701,12.840,
1819.70679,35.598,2898.27856,12.840,
1819.79822,36.598,2898.37012,12.840,
1819.88977,36.598,2898.46167,13.840,
1819.98132,35.598,2898.55322,12.840,
1820.07288,36.598,2898.64478,12.840,
1820.16431,36.598,2898.73633,12.840,
1820.25586,35.598,2898.82764,13.840,
1820.34741,35.598,2898.91919,12.840,
1820.43896,35.598,2899.01074,12.840,
1820.53040,36.598,2899.10229,13.840,
1820.62195,35.598,2899.19385,13.840,
1820.71350,35.598,2899.28540,12.840,
1820.80505,35.598,2899.37695,13.840,
1820.89648,36.598,2899.46826,12.840,
1820.98804,35.598,2899.55981,12.840,
1821.07959,37.598,2899.65137,12.840,
1821.17114,36.598,2899.74292,12.840,
1821.26257,35.598,2899.83447,12.840,
1821.35413,37.598,2899.92603,12.840,
1821.44568,36.598,2900.01758,12.840,
1821.53723,36.598,2900.10913,12.840,
1821.62866,36.598,2900.20044,11.840,
1821.72021,36.598,2900.29199,12.840,
1821.81177,35.598,2900.38354,12.840,
1821.90320,35.598,2900.47510,12.840,
1821.99475,36.598,2900.56665,12.840,
1822.08630,35.598,2900.65820,12.840,
1822.17786,35.598,2900.74976,12.840,
1822.26929,36.598,2900.84131,12.840,
1822.36084,35.598,2900.93262,13.840,
1822.45239,35.598,2901.02417,12.840,
1822.54395,36.598,2901.11572,12.840,
1822.63538,35.598,2901.20728,13.840,
1822.72693,35.598,2901.29883,13.840,
1822.81848,36.598,2901.39038,12.840,
1822.91003,35.598,2901.48193,12.840,
1823.00146,35.598,2901.57324,12.840,
1823.09302,35.598,2901.66479,12.840,
1823.18457,36.598,2901.75635,13.840,
1823.27612,36.598,2901.84790,12.840,
1823.36755,35.598,2901.93945,13.840,
1823.45911,36.598,2902.03101,13.840,
1823.55066,36.598,2902.12256,12.840,
1823.64209,36.598,2902.21411,13.840,
1823.73364,36.598,2902.30542,13.840,
1823.82520,36.598,2902.39697,13.840,
1823.91675,36.598,2902.48853,13.840,
1824.00818,36.598,2902.58008,13.840,
1824.09973,36.598,2902.67163,12.840,
1824.19128,36.598,2902.76318,13.840,
1824.28284,36.598,2902.85474,12.840,
1824.37427,36.598,2902.94604,13.840,
1824.46582,36.598,2903.03760,12.840,
1824.55737,36.598,2903.12915,13.840,
1824.64893,36.598,2903.22070,13.840,
1824.74036,36.598,2903.31226,13.840,
1824.83191,36.598,2903.40381,13.840,
1824.92346,36.598,2903.49536,13.840,
1825.01501,36.598,2903.58691,13.840,
1825.10645,36.598,2903.67822,13.840,
1825.19800,36.598,2903.76978,13.840,
1825.28955,36.598,2903.86133,13.840,
1825.38098,36.598,2903.95288,12.840,
1825.47253,36.598,2904.04443,13.840,
1825.56409,36.598,2904.13599,13.840,
1825.65564,36.598,2904.22754,13.840,
1825.74707,36.598,2904.31909,13.840,
1825.83862,36.598,2904.41040,13.840,
1825.93018,36.598,2904.50195,13.840,
1826.02173,36.598,2904.59351,13.840,
1826.11316,36.598,2904.68506,13.840,
1826.20471,36.598,2904.77661,13.840,
1826.29626,36.598,2904.86816,13.840,
1826.38782,36.598,2904.95972,13.840,
1826.47925,36.598,2905.05103,13.840,
1826.57080,36.598,2905.14258,13.840,
1826.66235,36.598,2905.23413,13.840,
1826.75391,35.598,2905.32568,13.840,
1826.84534,36.598,2905.41724,13.840,
1826.93689,37.598,2905.50879,13.840,
1827.02844,36.598,2905.60034,13.840,
1827.12000,36.598,2905.69189,13.840,
1827.21143,37.598,2905.78320,13.840,
1827.30298,37.598,2905.87476,13.840,
1827.39453,36.598,2905.96631,13.840,
1827.48596,36.598,2906.05786,13.840,
1827.57751,36.598,2906.14941,14.840,
1827.66907,36.598,2906.24097,13.840,
1827.76062,36.598,2906.33252,13.840,
1827.85205,37.598,2906.42407,13.840,
1827.94360,37.598,2906.51538,13.840,
1828.03516,36.598,2906.60693,13.840,
1828.12671,36.598,2906.69849,13.840,
1828.21814,36.598,2906.79004,13.840,
1828.30969,36.598,2906.88159,14.840,
1828.40125,37.598,2906.97314,13.840,
1828.49280,37.598,2907.06470,13.840,
1828.58423,37.598,2907.15601,13.840,
1828.67578,37.598,2907.24756,13.840,
1828.76733,37.598,2907.33911,13.840,
1828.85889,36.598,2907.43066,13.840,
1828.95032,36.598,2907.52222,13.840,
1829.04187,36.598,2907.61377,14.840,
1829.13342,36.598,2907.70532,13.840,
1829.22485,36.598,2907.79688,13.840,
1829.31641,36.598,2907.88818,13.840,
1829.40796,36.598,2907.97974,13.840,
1829.49951,36.598,2908.07129,14.840,
1829.59094,37.598,2908.16284,13.840,
1829.68250,36.598,2908.25439,13.840,
1829.77405,36.598,2908.34595,13.840,
1829.86560,37.598,2908.43750,13.840,
1829.95703,37.598,2908.52905,13.840,
1830.04858,37.598,2908.62036,13.840,
1830.14014,36.598,2908.71191,13.840,
1830.23169,37.598,2908.80347,13.840,
1830.32312,37.598,2908.89502,13.840,
1830.41467,36.598,2908.98657,13.840,
1830.50623,36.598,2909.07813,13.840,
1830.59778,37.598,2909.16968,13.840,
1830.68921,36.598,2909.26099,13.840,
1830.78076,36.598,2909.35254,13.840,
1830.87231,37.598,2909.44409,13.840,
1830.96387,37.598,2909.53564,13.840,
1831.05530,36.598,2909.62720,13.840,
1831.14685,36.598,2909.71875,13.840,
1831.23840,36.598,2909.81030,13.840,
1831.32983,37.598,2909.90186,13.840,
1831.42139,37.598,2909.99316,14.840,
1831.51294,37.598,2910.08472,13.840,
1831.60449,36.598,2910.17627,13.840,
1831.69592,36.598,2910.26782,14.840,
1831.78748,37.598,2910.35938,13.840,
1831.87903,37.598,2910.45093,13.840,
1831.97058,37.598,2910.54248,14.840,
1832.06201,36.598,2910.63379,14.840,
1832.15356,36.598,2910.72534,14.840,
1832.24512,36.598,2910.81689,14.840,
1832.33667,37.598,2910.90845,14.840,
1832.42810,37.598,2911.00000,14.840,
1832.51965,36.598,2911.09155,14.840,
1832.61121,36.598,2911.18311,13.840,
1832.70276,37.598,2911.27466,13.840,
1832.79419,37.598,2911.36597,12.840,
1832.88574,37.598,2911.45752,13.840,
1832.97729,37.598,2911.54907,13.840,
1833.06873,36.598,2911.64063,12.840,
1833.16028,36.598,2911.73218,13.840,
1833.25183,36.598,2911.82373,13.840,
1833.34338,36.598,2911.91528,13.840,
1833.43481,37.598,2912.00684,13.840,
1833.52637,36.598,2912.09814,13.840,
1833.61792,37.598,2912.18970,13.840,
1833.70947,37.598,2912.28125,14.840,
1833.80090,37.598,2912.37280,14.840,
1833.89246,36.598,2912.46436,14.840,
1833.98401,37.598,2912.55591,13.840,
1834.07556,36.598,2912.64746,14.840,
1834.16699,37.598,2912.73877,14.840,
1834.25854,38.598,2912.83032,13.840,
1834.35010,37.598,2912.92188,14.840,
1834.44165,36.598,2913.01343,14.840,
1834.53308,37.598,2913.10498,14.840,
1834.62463,37.598,2913.19653,13.840,
1834.71619,37.598,2913.28809,14.840,
1834.80762,37.598,2913.37964,14.840,
1834.89917,37.598,2913.47095,14.840,
1834.99072,37.598,2913.56250,14.840,
1835.08228,37.598,2913.65405,14.840,
1835.17371,37.598,2913.74561,14.840,
1835.26526,37.598,2913.83716,14.840,
1835.35681,37.598,2913.92871,14.840,
1835.44836,37.598,2914.02026,14.840,
1835.53979,37.598,2914.11182,14.840,
1835.63135,37.598,2914.20313,14.840,
1835.72290,37.598,2914.29468,14.840,
1835.81445,37.598,2914.38623,14.840,
1835.90588,37.598,2914.47778,14.840,
1835.99744,37.598,2914.56934,14.840,
1836.08899,37.598,2914.66089,14.840,
1836.18054,37.598,2914.75244,14.840,
1836.27197,37.598,2914.84375,14.840,
1836.36353,38.598,2914.93530,15.840,
1836.45508,38.598,2915.02686,14.840,
1836.54663,37.598,2915.11841,14.840,
1836.63806,37.598,2915.20996,14.840,
1836.72961,37.598,2915.30151,14.840,
1836.82117,37.598,2915.39307,14.840,
1836.91260,37.598,2915.48462,14.840,
1837.00415,38.598,2915.57593,14.840,
1837.09570,37.598,2915.66748,14.840,
1837.18726,37.598,2915.75903,14.840,
1837.27869,38.598,2915.85059,14.840,
1837.37024,37.598,2915.94214,14.840,
1837.46179,37.598,2916.03369,14.840,
1837.55334,37.598,2916.12524,14.840,
1837.64478,38.598,2916.21655,14.840,
1837.73633,37.598,2916.30811,14.840,
1837.82788,38.598,2916.39966,15.840,
1837.91943,38.598,2916.49121,14.840,
1838.01086,37.598,2916.58276,14.840,
1838.10242,37.598,2916.67432,14.840,
1838.19397,38.598,2916.76587,14.840,
1838.28552,38.598,2916.85742,14.840,
1838.37695,37.598,2916.94873,15.840,
1838.46851,37.598,2917.04028,15.840,
1838.56006,38.598,2917.13184,14.840,
1838.65149,38.598,2917.22339,14.840,
1838.74304,38.598,2917.31494,14.840,
1838.83459,37.598,2917.40649,14.840,
1838.92615,37.598,2917.49805,14.840,
1839.01758,37.598,2917.58960,15.840,
1839.10913,38.598,2917.68091,14.840,
1839.20068,38.598,2917.77246,15.840,
1839.29224,37.598,2917.86401,15.840,
1839.38367,37.598,2917.95557,15.840,
1839.47522,38.598,2918.04712,15.840,
1839.56677,38.598,2918.13867,15.840,
1839.65833,37.598,2918.23022,15.840,
1839.74976,38.598,2918.32153,14.840,
1839.84131,37.598,2918.41309,15.840,
1839.93286,37.598,2918.50464,15.840,
1840.02441,37.598,2918.59619,15.840,
1840.11584,38.598,2918.68774,15.840,
1840.20740,38.598,2918.77930,15.840,
1840.29895,38.598,2918.87085,15.840,
1840.39050,38.598,2918.96240,14.840,
1840.48193,38.598,2919.05371,14.840,
1840.57349,37.598,2919.14526,15.840,
1840.66504,38.598,2919.23682,15.840,
1840.75647,38.598,2919.32837,15.840,
1840.84802,37.598,2919.41992,15.840,
1840.93958,38.598,2919.51147,15.840,
1841.03113,38.598,2919.60303,15.840,
1841.12256,38.598,2919.69458,15.840,
1841.21411,38.598,2919.78589,15.840,
1841.30566,38.598,2919.87744,15.840,
1841.39722,38.598,2919.96899,15.840,
1841.48865,38.598,2920.06055,15.840,
1841.58020,38.598,2920.15210,15.840,
1841.67175,38.598,2920.24365,15.840,
1841.76331,38.598,2920.33521,15.840,
1841.85474,38.598,2920.42651,15.840,
1841.94629,38.598,2920.51807,15.840,
1842.03784,37.598,2920.60962,15.840,
1842.12939,38.598,2920.70117,15.840,
1842.22083,38.598,2920.79272,15.840,
1842.31238,38.598,2920.88428,14.840,
1842.40393,38.598,2920.97583,15.840,
1842.49536,38.598,2921.06738,15.840,
1842.58691,38.598,2921.15869,15.840,
1842.67847,38.598,2921.25024,15.840,
1842.77002,39.598,2921.34180,14.840,
1842.86145,38.598,2921.43335,15.840,
1842.95300,38.598,2921.52490,15.840,
1843.04456,38.598,2921.61646,15.840,
1843.13611,39.598,2921.70801,15.840,
1843.22754,38.598,2921.79932,15.840,
1843.31909,38.598,2921.89087,15.840,
1843.41064,39.598,2921.98242,15.840,
1843.50220,38.598,2922.07397,15.840,
1843.59363,38.598,2922.16553,15.840,
1843.68518,38.598,2922.25708,15.840,
1843.77673,38.598,2922.34863,15.840,
1843.86829,38.598,2922.44019,15.840,
1843.95972,38.598,2922.53149,15.840,
1844.05127,39.598,2922.62305,15.840,
1844.14282,38.598,2922.71460,15.840,
1844.23425,38.598,2922.80615,15.840,
1844.32581,39.598,2922.89771,15.840,
1844.41736,38.598,2922.98926,15.840,
1844.50891,39.598,2923.08081,16.840,
1844.60034,39.598,2923.17236,15.840,
1844.69189,39.598,2923.26367,15.840,
1844.78345,38.598,2923.35522,15.840,
1844.87500,38.598,2923.44678,15.840,
1844.96643,38.598,2923.53833,15.840,
1845.05798,38.598,2923.62988,15.840,
1845.14954,38.598,2923.72144,16.840,
1845.24109,39.598,2923.81299,15.840,
1845.33252,39.598,2923.90430,15.840,
1845.42407,39.598,2923.99585,15.840,
1845.51563,38.598,2924.08740,15.840,
1845.60718,39.598,2924.17896,15.840,
1845.69861,38.598,2924.27051,15.840,
1845.79016,38.598,2924.36206,16.840,
1845.88171,39.598,2924.45361,15.840,
1845.97327,39.598,2924.54517,15.840,
1846.06470,39.598,2924.63647,16.840,
1846.15625,39.598,2924.72803,15.840,
1846.24780,39.598,2924.81958,15.840,
1846.33923,39.598,2924.91113,15.840,
1846.43079,39.598,2925.00269,15.840,
1846.52234,39.598,2925.09424,15.840,
1846.61389,39.598,2925.18579,16.840,
1846.70532,38.598,2925.27734,15.840,
1846.79688,38.598,2925.36865,15.840,
1846.88843,38.598,2925.46021,15.840,
1846.97998,38.598,2925.55176,16.840,
1847.07141,38.598,2925.64331,16.840,
1847.16296,38.598,2925.73486,15.840,
1847.25452,38.598,2925.82642,16.840,
1847.34607,38.598,2925.91797,15.840,
1847.43750,39.598,2926.00928,16.840,
1847.52905,38.598,2926.10083,16.840,
1847.62061,39.598,2926.19238,15.840,
1847.71216,39.598,2926.28394,16.840,
1847.80359,39.598,2926.37549,16.840,
1847.89514,39.598,2926.46704,16.840,
1847.98669,39.598,2926.55859,16.840,
1848.07813,39.598,2926.65015,16.840,
1848.16968,38.598,2926.74146,16.840,
1848.26123,38.598,2926.83301,16.840,
1848.35278,39.598,2926.92456,16.840,
1848.44421,38.598,2927.01611,17.840,
1848.53577,38.598,2927.10767,17.840,
1848.62732,39.598,2927.19922,17.840,
1848.71887,38.598,2927.29077,16.840,
1848.81030,38.598,2927.38208,16.840,
1848.90186,39.598,2927.47363,17.840,
1848.99341,38.598,2927.56519,16.840,
1849.08496,39.598,2927.65674,16.840,
1849.17639,38.598,2927.74829,16.840,
1849.26794,39.598,2927.83984,15.840,
1849.35950,39.598,2927.93140,16.840,
1849.45105,39.598,2928.02295,16.840,
1849.54248,39.598,2928.11426,16.840,
1849.63403,39.598,2928.20581,16.840,
1849.72559,38.598,2928.29736,16.840,
1849.81714,39.598,2928.38892,16.840,
1849.90857,39.598,2928.48047,16.840,
1850.00012,39.598,2928.57202,16.840,
1850.09167,39.598,2928.66357,16.840,
1850.18311,39.598,2928.75513,16.840,
1850.27466,39.598,2928.84644,16.840,
1850.36621,39.598,2928.93799,16.840,
1850.45776,39.598,2929.02954,16.840,
1850.54919,39.598,2929.12109,15.840,
1850.64075,39.598,2929.21265,15.840,
1850.73230,39.598,2929.30420,15.840,
1850.82385,39.598,2929.39575,15.840,
1850.91528,39.598,2929.48706,16.840,
1851.00684,39.598,2929.57861,17.840,
1851.09839,40.598,2929.67017,17.840,
1851.18994,39.598,2929.76172,16.840,
1851.28137,39.598,2929.85327,16.840,
1851.37292,39.598,2929.94482,15.840,
1851.46448,39.598,2930.03638,16.840,
1851.55603,39.598,2930.12793,16.840,
1851.64746,39.598,2930.21924,16.840,
1851.73901,39.598,2930.31079,16.840,
1851.83057,40.598,2930.40234,15.840,
1851.92200,39.598,2930.49390,15.840,
1852.01355,40.598,2930.58545,16.840,
1852.10510,39.598,2930.67700,16.840,
1852.19666,39.598,2930.76855,16.840,
1852.28809,39.598,2930.86011,15.840,
1852.37964,39.598,2930.95142,16.840,
1852.47119,39.598,2931.04297,16.840,
1852.56274,39.598,2931.13452,16.840,
1852.65417,39.598,2931.22607,15.840,
1852.74573,39.598,2931.31763,15.840,
1852.83728,39.598,2931.40918,16.840,
1852.92883,39.598,2931.50073,16.840,
1853.02026,39.598,2931.59204,16.840,
1853.11182,39.598,2931.68359,16.840,
1853.20337,40.598,2931.77515,16.840,
1853.29492,40.598,2931.86670,16.840,
1853.38635,40.598,2931.95825,16.840,
1853.47791,40.598,2932.04980,16.840,
1853.56946,40.598,2932.14136,16.840,
1853.66089,39.598,2932.23291,16.840,
1853.75244,39.598,2932.32422,16.840,
1853.84399,40.598,2932.41577,16.840,
1853.93555,40.598,2932.50732,16.840,
1854.02698,40.598,2932.59888,17.840,
1854.11853,40.598,2932.69043,16.840,
1854.21008,40.598,2932.78198,16.840,
1854.30164,40.598,2932.87354,16.840,
1854.39307,40.598,2932.96509,16.840,
1854.48462,40.598,2933.05640,16.840,
1854.57617,40.598,2933.14795,16.840,
1854.66772,40.598,2933.23950,16.840,
1854.75916,41.598,2933.33105,15.840,
1854.85071,40.598,2933.42261,16.840,
1854.94226,40.598,2933.51416,16.840,
1855.03381,40.598,2933.60571,16.840,
1855.12524,40.598,2933.69702,16.840,
1855.21680,40.598,2933.78857,16.840,
1855.30835,40.598,2933.88013,16.840,
1855.39990,40.598,2933.97168,17.840,
1855.49133,40.598,2934.06323,16.840,
1855.58289,40.598,2934.15479,17.840,
1855.67444,40.598,2934.24634,16.840,
1855.76587,39.598,2934.33789,16.840,
1855.85742,40.598,2934.42920,16.840,
1855.94897,40.598,2934.52075,17.840,
1856.04053,40.598,2934.61230,16.840,
1856.13196,40.598,2934.70386,17.840,
1856.22351,40.598,2934.79541,16.840,
1856.31506,40.598,2934.88696,16.840,
1856.40662,40.598,2934.97852,16.840,
1856.49805,40.598,2935.06982,16.840,
1856.58960,40.598,2935.16138,16.840,
1856.68115,40.598,2935.25293,16.840,
1856.77271,40.598,2935.34448,17.840,
1856.86414,40.598,2935.43604,17.840,
1856.95569,40.598,2935.52759,16.840,
1857.04724,40.598,2935.61914,16.840,
1857.13879,40.598,2935.71069,16.840,
1857.23022,40.598,2935.80200,16.840,
1857.32178,40.598,2935.89355,16.840,
1857.41333,40.598,2935.98511,16.840,
1857.50476,40.598,2936.07666,16.840,
1857.59631,40.598,2936.16821,16.840,
1857.68787,41.598,2936.25977,17.840,
1857.77942,40.598,2936.35132,17.840,
1857.87085,40.598,2936.44287,16.840,
1857.96240,40.598,2936.53418,17.840,
1858.05396,40.598,2936.62573,17.840,
1858.14551,40.598,2936.71729,16.840,
1858.23694,40.598,2936.80884,17.840,
1858.32849,40.598,2936.90039,17.840,
1858.42004,40.598,2936.99194,17.840,
1858.51160,40.598,2937.08350,16.840,
1858.60303,40.598,2937.17480,16.840,
1858.69458,40.598,2937.26636,17.840,
1858.78613,40.598,2937.35791,16.840,
1858.87769,40.598,2937.44946,17.840,
1858.96912,40.598,2937.54102,17.840,
1859.06067,40.598,2937.63257,16.840,
1859.15222,41.598,2937.72412,16.840,
1859.24377,40.598,2937.81567,16.840,
1859.33521,40.598,2937.90698,16.840,
1859.42676,40.598,2937.99854,16.840,
1859.51831,40.598,2938.09009,16.840,
1859.60974,40.598,2938.18164,17.840,
1859.70129,40.598,2938.27319,16.840,
1859.79285,40.598,2938.36475,17.840,
1859.88440,40.598,2938.45630,16.840,
1859.97583,40.598,2938.54785,17.840,
1860.06738,40.598,2938.63916,16.840,
1860.15894,40.598,2938.73071,16.840,
1860.25049,40.598,2938.82227,17.840,
1860.34192,41.598,2938.91382,17.840,
1860.43347,40.598,2939.00537,16.840,
1860.52502,40.598,2939.09692,16.840,
1860.61658,41.598,2939.18848,16.840,
1860.70801,41.598,2939.27979,17.840,
1860.79956,40.598,2939.37134,16.840,
1860.89111,41.598,2939.46289,17.840,
1860.98267,40.598,2939.55444,16.840,
1861.07410,41.598,2939.64600,17.840,
1861.16565,41.598,2939.73755,17.840,
1861.25720,41.598,2939.82910,17.840,
1861.34863,41.598,2939.92065,17.840,
1861.44019,40.598,2940.01196,17.840,
1861.53174,41.598,2940.10352,17.840,
1861.62329,41.598,2940.19507,17.840,
1861.71472,40.598,2940.28662,17.840,
1861.80627,41.598,2940.37817,16.840,
1861.89783,41.598,2940.46973,17.840,
1861.98938,41.598,2940.56128,17.840,
1862.08081,41.598,2940.65259,17.840,
1862.17236,41.598,2940.74414,16.840,
1862.26392,41.598,2940.83569,17.840,
1862.35547,41.598,2940.92725,16.840,
1862.44690,41.598,2941.01880,17.840,
1862.53845,41.598,2941.11035,17.840,
1862.63000,41.598,2941.20190,17.840,
1862.72156,41.598,2941.29346,18.840,
1862.81299,41.598,2941.38477,17.840,
1862.90454,41.598,2941.47632,17.840,
1862.99609,41.598,2941.56787,17.840,
1863.08752,41.598,2941.65942,17.840,
1863.17908,41.598,2941.75098,17.840,
1863.27063,41.598,2941.84253,17.840,
1863.36218,41.598,2941.93408,17.840,
1863.45361,41.598,2942.02563,17.840,
1863.54517,41.598,2942.11694,17.840,
1863.63672,41.598,2942.20850,16.840,
1863.72827,41.598,2942.30005,16.840,
1863.81970,41.598,2942.39160,17.840,
1863.91125,41.598,2942.48315,17.840,
1864.00281,41.598,2942.57471,16.840,
1864.09436,41.598,2942.66626,17.840,
1864.18579,41.598,2942.75757,18.840,
1864.27734,42.598,2942.84912,17.840,
1864.36890,41.598,2942.94067,17.840,
1864.46045,41.598,2943.03223,17.840,
1864.55188,41.598,2943.12378,16.840,
1864.64343,41.598,2943.21533,17.840,
1864.73499,41.598,2943.30688,17.840,
1864.82654,42.598,2943.39844,17.840,
1864.91797,41.598,2943.48975,17.840,
1865.00952,42.598,2943.58130,17.840,
1865.10107,41.598,2943.67285,17.840,
1865.19250,41.598,2943.76440,17.840,
1865.28406,41.598,2943.85596,17.840,
1865.37561,42.598,2943.94751,17.840,
1865.46716,41.598,2944.03906,17.840,
1865.55859,42.598,2944.13062,17.840,
1865.65015,42.598,2944.22192,18.840,
1865.74170,42.598,2944.31348,17.840,
1865.83325,42.598,2944.40503,17.840,
1865.92468,42.598,2944.49658,17.840,
1866.01624,41.598,2944.58813,17.840,
1866.10779,41.598,2944.67969,17.840,
1866.19934,41.598,2944.77124,17.840,
1866.29077,41.598,2944.86255,17.840,
1866.38232,42.598,2944.95410,17.840,
1866.47388,42.598,2945.04565,17.840,
1866.56543,42.598,2945.13721,17.840,
1866.65686,41.598,2945.22876,17.840,
1866.74841,42.598,2945.32031,17.840,
1866.83997,41.598,2945.41187,17.840,
1866.93140,42.598,2945.50342,17.840,
1867.02295,42.598,2945.59473,17.840,
1867.11450,41.598,2945.68628,18.840,
1867.20605,41.598,2945.77783,17.840,
1867.29749,41.598,2945.86938,17.840,
1867.38904,42.598,2945.96094,17.840,
1867.48059,41.598,2946.05249,17.840,
1867.57214,41.598,2946.14404,17.840,
1867.66357,41.598,2946.23535,17.840,
1867.75513,41.598,2946.32690,17.840,
1867.84668,41.598,2946.41846,17.840,
1867.93823,42.598,2946.51001,17.840,
1868.02966,41.598,2946.60156,17.840,
1868.12122,42.598,2946.69312,17.840,
1868.21277,41.598,2946.78467,18.840,
1868.30432,42.598,2946.87622,18.840,
1868.39575,41.598,2946.96753,17.840,
1868.48730,42.598,2947.05908,18.840,
1868.57886,42.598,2947.15063,18.840,
1868.67041,42.598,2947.24219,18.840,
1868.76184,41.598,2947.33374,17.840,
1868.85339,41.598,2947.42529,17.840,
1868.94495,41.598,2947.51685,17.840,
1869.03638,41.598,2947.60840,17.840,
1869.12793,41.598,2947.69971,17.840,
1869.21948,42.598,2947.79126,17.840,
1869.31104,42.598,2947.88281,17.840,
1869.40247,42.598,2947.97437,17.840,
1869.49402,42.598,2948.06592,16.840,
1869.58557,42.598,2948.15747,17.840,
1869.67712,42.598,2948.24902,17.840,
1869.76855,42.598,2948.34033,17.840,
1869.86011,42.598,2948.43188,17.840,
1869.95166,42.598,2948.52344,17.840,
1870.04321,42.598,2948.61499,17.840,
1870.13464,42.598,2948.70654,17.840,
1870.22620,42.598,2948.79810,17.840,
1870.31775,42.598,2948.88965,17.840,
1870.40930,42.598,2948.98120,17.840,
1870.50073,42.598,2949.07251,18.840,
1870.59229,41.598,2949.16406,18.840,
1870.68384,41.598,2949.25562,17.840,
1870.77527,41.598,2949.34717,18.840,
1870.86682,41.598,2949.43872,18.840,
1870.95837,41.598,2949.53027,17.840,
1871.04993,41.598,2949.62183,17.840,
1871.14136,41.598,2949.71338,17.840,
1871.23291,40.598,2949.80469,18.840,
1871.32446,41.598,2949.89624,17.840,
1871.41602,41.598,2949.98779,17.840,
1871.50745,41.598,2950.07935,19.840,
1871.59900,41.598,2950.17090,18.840,
1871.69055,42.598,2950.26245,18.840,
1871.78210,42.598,2950.35400,18.840,
1871.87354,41.598,2950.44531,18.840,
1871.96509,42.598,2950.53687,19.840,
1872.05664,42.598,2950.62842,18.840,
1872.14819,42.598,2950.71997,18.840,
1872.23962,43.598,2950.81152,18.840,
1872.33118,43.598,2950.90308,18.840,
1872.42273,42.598,2950.99463,18.840,
1872.51416,43.598,2951.08618,18.840,
1872.60571,43.598,2951.17749,18.840,
1872.69727,42.598,2951.26904,18.840,
1872.78882,43.598,2951.36060,18.840,
1872.88025,42.598,2951.45215,18.840,
1872.97180,43.598,2951.54370,19.840,
1873.06335,42.598,2951.63525,19.840,
1873.15491,43.598,2951.72681,18.840,
1873.24634,43.598,2951.81836,18.840,
1873.33789,42.598,2951.90967,18.840,
1873.42944,42.598,2952.00122,18.840,
1873.52100,42.598,2952.09277,18.840,
1873.61243,43.598,2952.18433,19.840,
1873.70398,42.598,2952.27588,18.840,
1873.79553,43.598,2952.36743,18.840,
1873.88708,43.598,2952.45898,18.840,
1873.97852,43.598,2952.55029,18.840,
1874.07007,43.598,2952.64185,18.840,
1874.16162,43.598,2952.73340,18.840,
1874.25317,42.598,2952.82495,18.840,
1874.34460,43.598,2952.91650,18.840,
1874.43616,43.598,2953.00806,19.840,
1874.52771,43.598,2953.09961,18.840,
1874.61914,43.598,2953.19116,18.840,
1874.71069,42.598,2953.28247,18.840,
1874.80225,43.598,2953.37402,18.840,
1874.89380,43.598,2953.46558,18.840,
1874.98523,43.598,2953.55713,18.840,
1875.07678,43.598,2953.64868,18.840,
1875.16833,43.598,2953.74023,18.840,
1875.25989,43.598,2953.83179,18.840,
1875.35132,43.598,2953.92310,18.840,
1875.44287,43.598,2954.01465,18.840,
1875.53442,43.598,2954.10620,18.840,
1875.62598,42.598,2954.19775,18.840,
1875.71741,43.598,2954.28931,19.840,
1875.80896,43.598,2954.38086,18.840,
1875.90051,43.598,2954.47241,19.840,
1875.99207,43.598,2954.56396,18.840,
1876.08350,42.598,2954.65527,18.840,
1876.17505,42.598,2954.74683,18.840,
1876.26660,42.598,2954.83838,18.840,
1876.35803,43.598,2954.92993,18.840,
1876.44958,42.598,2955.02148,19.840,
1876.54114,43.598,2955.11304,18.840,
1876.63269,43.598,2955.20459,18.840,
1876.72412,43.598,2955.29614,18.840,
1876.81567,43.598,2955.38745,18.840,
1876.90723,42.598,2955.47900,18.840,
1876.99878,43.598,2955.57056,18.840,
1877.09021,42.598,2955.66211,18.840,
1877.18176,43.598,2955.75366,18.840,
1877.27332,43.598,2955.84521,18.840,
1877.36487,43.598,2955.93677,19.840,
1877.45630,43.598,2956.02808,19.840,
1877.54785,43.598,2956.11963,18.840,
1877.63940,42.598,2956.21118,18.840,
1877.73096,43.598,2956.30273,18.840,
1877.82239,43.598,2956.39429,18.840,
1877.91394,43.598,2956.48584,19.840,
1878.00549,43.598,2956.57739,18.840,
1878.09705,43.598,2956.66895,18.840,
1878.18848,43.598,2956.76025,18.840,
1878.28003,43.598,2956.85181,19.840,
1878.37158,43.598,2956.94336,18.840,
1878.46301,43.598,2957.03491,19.840,
1878.55457,43.598,2957.12646,18.840,
1878.64612,43.598,2957.21802,18.840,
1878.73767,44.598,2957.30957,18.840,
1878.82910,43.598,2957.40112,19.840,
1878.92065,43.598,2957.49243,18.840,
1879.01221,43.598,2957.58398,19.840,
1879.10376,43.598,2957.67554,19.840,
1879.19519,43.598,2957.76709,19.840,
1879.28674,43.598,2957.85864,19.840,
1879.37830,43.598,2957.95020,19.840,
1879.46985,43.598,2958.04175,19.840,
1879.56128,43.598,2958.13306,19.840,
1879.65283,43.598,2958.22461,18.840,
1879.74438,43.598,2958.31616,19.840,
1879.83594,43.598,2958.40771,19.840,
1879.92737,43.598,2958.49927,18.840,
1880.01892,43.598,2958.59082,18.840,
1880.11047,43.598,2958.68237,19.840,
1880.20190,43.598,2958.77393,18.840,
1880.29346,43.598,2958.86523,19.840,
1880.38501,43.598,2958.95679,18.840,
1880.47656,43.598,2959.04834,19.840,
1880.56799,43.598,2959.13989,18.840,
1880.65955,43.598,2959.23145,18.840,
1880.75110,43.598,2959.32300,19.840,
1880.84265,43.598,2959.41455,19.840,
1880.93408,43.598,2959.50586,19.840,
1881.02563,43.598,2959.59741,19.840,
1881.11719,44.598,2959.68896,19.840,
1881.20874,43.598,2959.78052,18.840,
1881.30017,43.598,2959.87207,19.840,
1881.39172,43.598,2959.96362,19.840,
1881.48328,43.598,2960.05518,18.840,
1881.57483,43.598,2960.14673,19.840,
1881.66626,44.598,2960.23804,19.840,
1881.75781,44.598,2960.32959,20.840,
1881.84937,43.598,2960.42114,19.840,
1881.94080,44.598,2960.51270,19.840,
1882.03235,44.598,2960.60425,19.840,
1882.12390,44.598,2960.69580,19.840,
1882.21545,43.598,2960.78735,19.840,
1882.30688,43.598,2960.87891,19.840,
1882.39844,44.598,2960.97021,19.840,
1882.48999,43.598,2961.06177,19.840,
1882.58154,44.598,2961.15332,19.840,
1882.67297,44.598,2961.24487,19.840,
1882.76453,44.598,2961.33643,18.840,
1882.85608,43.598,2961.42798,19.840,
1882.94763,43.598,2961.51953,19.840,
1883.03906,43.598,2961.61084,19.840,
1883.13062,43.598,2961.70239,19.840,
1883.22217,43.598,2961.79395,20.840,
1883.31372,43.598,2961.88550,19.840,
1883.40515,43.598,2961.97705,19.840,
1883.49670,43.598,2962.06860,20.840,
1883.58826,44.598,2962.16016,19.840,
1883.67981,43.598,2962.25171,19.840,
1883.77124,43.598,2962.34302,19.840,
1883.86279,44.598,2962.43457,20.840,
1883.95435,43.598,2962.52612,19.840,
1884.04578,44.598,2962.61768,19.840,
1884.13733,44.598,2962.70923,20.840,
1884.22888,44.598,2962.80078,20.840,
1884.32043,44.598,2962.89233,20.840,
1884.41187,44.598,2962.98389,20.840,
1884.50342,44.598,2963.07520,20.840,
1884.59497,44.598,2963.16675,20.840,
1884.68652,43.598,2963.25830,20.840,
1884.77795,44.598,2963.34985,20.840,
1884.86951,44.598,2963.44141,20.840,
1884.96106,43.598,2963.53296,20.840,
1885.05261,43.598,2963.62451,20.840,
1885.14404,43.598,2963.71582,19.840,
1885.23560,43.598,2963.80737,19.840,
1885.32715,43.598,2963.89893,20.840,
1885.41870,44.598,2963.99048,19.840,
1885.51013,43.598,2964.08203,19.840,
1885.60168,43.598,2964.17358,20.840,
1885.69324,43.598,2964.26514,20.840,
1885.78467,44.598,2964.35669,19.840,
1885.87622,44.598,2964.44800,20.840,
1885.96777,44.598,2964.53955,19.840,
1886.05933,44.598,2964.63110,20.840,
1886.15076,44.598,2964.72266,19.840,
1886.24231,44.598,2964.81421,20.840,
1886.33386,43.598,2964.90576,19.840,
1886.42542,44.598,2964.99731,20.840,
1886.51685,43.598,2965.08862,20.840,
1886.60840,44.598,2965.18018,21.840,
1886.69995,44.598,2965.27173,20.840,
1886.79150,44.598,2965.36328,21.840,
1886.88293,44.598,2965.45483,21.840,
1886.97449,44.598,2965.54639,19.840,
1887.06604,44.598,2965.63794,20.840,
1887.15759,44.598,2965.72949,19.840,
1887.24902,44.598,2965.82080,19.840,
1887.34058,44.598,2965.91235,19.840,
1887.43213,44.598,2966.00391,19.840,
1887.52368,44.598,2966.09546,19.840,
1887.61511,44.598,2966.18701,20.840,
1887.70667,44.598,2966.27856,19.840,
1887.79822,43.598,2966.37012,20.840,
1887.88965,44.598,2966.46167,19.840,
1887.98120,44.598,2966.55298,19.840,
1888.07275,43.598,2966.64453,19.840,
1888.16431,43.598,2966.73608,20.840,
1888.25574,44.598,2966.82764,20.840,
1888.34729,44.598,2966.91919,20.840,
1888.43884,44.598,2967.01074,19.840,
1888.53040,44.598,2967.10229,20.840,
1888.62183,44.598,2967.19360,19.840,
1888.71338,44.598,2967.28516,19.840,
1888.80493,44.598,2967.37671,20.840,
1888.89648,44.598,2967.46826,19.840,
1888.98792,44.598,2967.55981,19.840,
1889.07947,44.598,2967.65137,20.840,
1889.17102,44.598,2967.74292,20.840,
1889.26257,44.598,2967.83447,19.840,
1889.35400,44.598,2967.92578,20.840,
1889.44556,44.598,2968.01733,19.840,
1889.53711,44.598,2968.10889,20.840,
1889.62854,44.598,2968.20044,20.840,
1889.72009,44.598,2968.29199,20.840,
1889.81165,44.598,2968.38354,19.840,
1889.90320,44.598,2968.47510,20.840,
1889.99463,44.598,2968.56665,19.840,
1890.08618,44.598,2968.65796,19.840,
1890.17773,45.598,2968.74951,20.840,
1890.26929,44.598,2968.84106,20.840,
1890.36072,44.598,2968.93262,20.840,
1890.45227,44.598,2969.02417,20.840,
1890.54382,44.598,2969.11572,20.840,
1890.63538,44.598,2969.20728,19.840,
1890.72681,44.598,2969.29858,20.840,
1890.81836,44.598,2969.39014,20.840,
1890.90991,44.598,2969.48169,20.840,
1891.00146,44.598,2969.57324,20.840,
1891.09290,43.598,2969.66479,20.840,
1891.18445,44.598,2969.75635,20.840,
1891.27600,43.598,2969.84790,20.840,
1891.36743,44.598,2969.93945,20.840,
1891.45898,43.598,2970.03076,20.840,
1891.55054,43.598,2970.12231,20.840,
1891.64209,43.598,2970.21387,20.840,
1891.73352,42.598,2970.30542,20.840,
1891.82507,43.598,2970.39697,20.840,
1891.91663,43.598,2970.48853,20.840,
1892.00818,43.598,2970.58008,20.840,
1892.09961,43.598,2970.67163,20.840,
1892.19116,43.598,2970.76294,20.840,
1892.28271,43.598,2970.85449,20.840,
1892.37427,44.598,2970.94604,20.840,
1892.46570,44.598,2971.03760,20.840,
1892.55725,44.598,2971.12915,20.840,
1892.64880,44.598,2971.22070,20.840,
1892.74036,44.598,2971.31226,20.840,
1892.83179,45.598,2971.40356,20.840,
1892.92334,45.598,2971.49512,20.840,
1893.01489,44.598,2971.58667,20.840,
1893.10645,45.598,2971.67822,20.840,
1893.19788,45.598,2971.76978,20.840,
1893.28943,44.598,2971.86133,20.840,
1893.38098,45.598,2971.95288,20.840,
1893.47241,45.598,2972.04443,21.840,
1893.56396,45.598,2972.13574,20.840,
1893.65552,44.598,2972.22729,20.840,
1893.74707,45.598,2972.31885,19.840,
1893.83850,45.598,2972.41040,20.840,
1893.93005,44.598,2972.50195,20.840,
1894.02161,45.598,2972.59351,20.840,
1894.11316,45.598,2972.68506,20.840,
1894.20459,44.598,2972.77637,20.840,
1894.29614,45.598,2972.86792,20.840,
1894.38770,45.598,2972.95947,20.840,
1894.47925,45.598,2973.05103,20.840,
1894.57068,44.598,2973.14258,20.840,
1894.66223,45.598,2973.23413,20.840,
1894.75378,45.598,2973.32568,20.840,
1894.84534,45.598,2973.41724,20.840,
1894.93677,45.598,2973.50854,21.840,
1895.02832,45.598,2973.60010,20.840,
1895.11987,44.598,2973.69165,20.840,
1895.21130,45.598,2973.78320,20.840,
1895.30286,44.598,2973.87476,20.840,
1895.39441,44.598,2973.96631,20.840,
1895.48596,45.598,2974.05786,21.840,
1895.57739,45.598,2974.14941,20.840,
1895.66895,45.598,2974.24072,20.840,
1895.76050,45.598,2974.33228,21.840,
1895.85205,45.598,2974.42383,20.840,
1895.94348,45.598,2974.51538,20.840,
1896.03503,45.598,2974.60693,20.840,
1896.12659,45.598,2974.69849,20.840,
1896.21814,45.598,2974.79004,20.840,
1896.30957,45.598,2974.88135,20.840,
1896.40112,45.598,2974.97290,21.840,
1896.49268,45.598,2975.06445,20.840,
1896.58423,45.598,2975.15601,20.840,
1896.67566,44.598,2975.24756,21.840,
1896.76721,45.598,2975.33911,21.840,
1896.85876,45.598,2975.43066,20.840,
1896.95020,45.598,2975.52222,21.840,
1897.04175,45.598,2975.61353,21.840,
1897.13330,46.598,2975.70508,20.840,
1897.22485,45.598,2975.79663,20.840,
1897.31628,45.598,2975.88818,20.840,
1897.40784,45.598,2975.97974,20.840,
1897.49939,45.598,2976.07129,20.840,
1897.59094,45.598,2976.16284,20.840,
1897.68237,45.598,2976.25439,20.840,
1897.77393,45.598,2976.34570,20.840,
1897.86548,45.598,2976.43726,21.840,
1897.95703,45.598,2976.52881,21.840,
1898.04846,45.598,2976.62036,21.840,
1898.14001,45.598,2976.71191,20.840,
1898.23157,45.598,2976.80347,21.840,
1898.32312,45.598,2976.89502,21.840,
1898.41455,45.598,2976.98633,21.840,
1898.50610,45.598,2977.07788,20.840,
1898.59766,45.598,2977.16943,20.840,
1898.68921,46.598,2977.26099,20.840,
1898.78064,45.598,2977.35254,21.840,
1898.87219,45.598,2977.44409,21.840,
1898.96375,46.598,2977.53564,20.840,
1899.05518,45.598,2977.62720,20.840,
1899.14673,45.598,2977.71851,21.840,
1899.23828,46.598,2977.81006,20.840,
1899.32983,45.598,2977.90161,21.840,
1899.42126,45.598,2977.99316,20.840,
1899.51282,45.598,2978.08472,21.840,
1899.60437,45.598,2978.17627,20.840,
1899.69592,45.598,2978.26782,21.840,
1899.78735,45.598,2978.35913,21.840,
1899.87891,45.598,2978.45068,21.840,
1899.97046,45.598,2978.54224,21.840,
1900.06201,45.598,2978.63379,21.840,
1900.15344,46.598,2978.72534,21.840,
1900.24500,46.598,2978.81689,21.840,
1900.33655,45.598,2978.90845,21.840,
1900.42810,45.598,2979.00000,21.840,
1900.51953,45.598,2979.09131,21.840,
1900.61108,45.598,2979.18286,21.840,
1900.70264,45.598,2979.27441,21.840,
1900.79407,45.598,2979.36597,21.840,
1900.88562,45.598,2979.45752,21.840,
1900.97717,45.598,2979.54907,21.840,
1901.06873,45.598,2979.64063,21.840,
1901.16016,46.598,2979.73218,21.840,
1901.25171,45.598,2979.82349,21.840,
1901.34326,45.598,2979.91504,21.840,
1901.43481,46.598,2980.00659,21.840,
1901.52625,45.598,2980.09814,21.840,
1901.61780,46.598,2980.18970,21.840,
1901.70935,46.598,2980.28125,21.840,
1901.80090,45.598,2980.37280,21.840,
1901.89233,46.598,2980.46411,21.840,
1901.98389,46.598,2980.55566,22.840,
1902.07544,46.598,2980.64722,23.840,
1902.16699,46.598,2980.73877,23.840,
1902.25842,45.598,2980.83032,24.840,
1902.34998,46.598,2980.92188,23.840,
1902.44153,45.598,2981.01343,23.840,
1902.53308,45.598,2981.10498,23.840,
1902.62451,45.598,2981.19629,23.840,
1902.71606,45.598,2981.28784,23.840,
1902.80762,45.598,2981.37939,22.840,
1902.89905,46.598,2981.47095,22.840,
1902.99060,45.598,2981.56250,22.840,
1903.08215,47.598,2981.65405,22.840,
1903.17371,46.598,2981.74561,22.840,
1903.26514,46.598,2981.83716,22.840,
1903.35669,46.598,2981.92847,21.840,
1903.44824,46.598,2982.02002,22.840,
1903.53979,46.598,2982.11157,21.840,
1903.63123,46.598,2982.20313,21.840,
1903.72278,45.598,2982.29468,22.840,
1903.81433,47.598,2982.38623,21.840,
1903.90588,46.598,2982.47778,21.840,
1903.99731,46.598,2982.56909,21.840,
1904.08887,46.598,2982.66064,21.840,
1904.18042,46.598,2982.75220,21.840,
1904.27197,46.598,2982.84375,21.840,
1904.36340,46.598,2982.93530,22.840,
1904.45496,46.598,2983.02686,21.840,
1904.54651,47.598,2983.11841,22.840,
1904.63794,46.598,2983.20996,22.840,
1904.72949,46.598,2983.30127,22.840,
1904.82104,46.598,2983.39282,22.840,
1904.91260,46.598,2983.48438,22.840,
1905.00403,46.598,2983.57593,22.840,
1905.09558,46.598,2983.66748,22.840,
1905.18713,46.598,2983.75903,22.840,
1905.27869,46.598,2983.85059,22.840,
1905.37012,46.598,2983.94189,22.840,
1905.46167,46.598,2984.03345,22.840,
1905.55322,46.598,2984.12500,22.840,
1905.64478,46.598,2984.21655,22.840,
1905.73621,46.598,2984.30811,22.840,
1905.82776,46.598,2984.39966,22.840,
1905.91931,46.598,2984.49121,22.840,
1906.01086,47.598,2984.58276,22.840,
1906.10229,47.598,2984.67407,22.840,
1906.19385,46.598,2984.76563,22.840,
1906.28540,46.598,2984.85718,21.840,
1906.37683,46.598,2984.94873,22.840,
1906.46838,46.598,2985.04028,22.840,
1906.55994,46.598,2985.13184,22.840,
1906.65149,46.598,2985.22339,22.840,
1906.74292,46.598,2985.31494,22.840,
1906.83447,46.598,2985.40625,22.840,
1906.92603,46.598,2985.49780,22.840,
1907.01758,46.598,2985.58936,22.840,
1907.10901,46.598,2985.68091,22.840,
1907.20056,46.598,2985.77246,22.840,
1907.29211,46.598,2985.86401,22.840,
1907.38367,46.598,2985.95557,22.840,
1907.47510,46.598,2986.04688,22.840,
1907.56665,46.598,2986.13843,22.840,
1907.65820,46.598,2986.22998,23.840,
1907.74976,46.598,2986.32153,22.840,
1907.84119,46.598,2986.41309,22.840,
1907.93274,46.598,2986.50464,22.840,
1908.02429,46.598,2986.59619,23.840,
1908.11584,46.598,2986.68774,23.840,
1908.20728,47.598,2986.77905,23.840,
1908.29883,46.598,2986.87061,23.840,
1908.39038,46.598,2986.96216,23.840,
1908.48181,46.598,2987.05371,22.840,
1908.57336,46.598,2987.14526,22.840,
1908.66492,46.598,2987.23682,22.840,
1908.75647,46.598,2987.32837,22.840,
1908.84790,46.598,2987.41992,23.840,
1908.93945,47.598,2987.51123,22.840,
1909.03101,47.598,2987.60278,23.840,
1909.12256,46.598,2987.69434,22.840,
1909.21399,46.598,2987.78589,22.840,
1909.30554,47.598,2987.87744,23.840,
1909.39709,47.598,2987.96899,22.840,
1909.48865,47.598,2988.06055,23.840,
1909.58008,47.598,2988.15186,23.840,
1909.67163,47.598,2988.24341,23.840,
1909.76318,47.598,2988.33496,22.840,
1909.85474,47.598,2988.42651,23.840,
1909.94617,47.598,2988.51807,23.840,
1910.03772,47.598,2988.60962,23.840,
1910.12927,47.598,2988.70117,23.840,
1910.22070,47.598,2988.79272,23.840,
1910.31226,47.598,2988.88403,23.840,
1910.40381,48.598,2988.97559,22.840,
1910.49536,47.598,2989.06714,23.840,
1910.58679,47.598,2989.15869,23.840,
1910.67834,47.598,2989.25024,22.840,
1910.76990,47.598,2989.34180,23.840,
1910.86145,47.598,2989.43335,23.840,
1910.95288,47.598,2989.52490,22.840,
1911.04443,47.598,2989.61621,23.840,
1911.13599,47.598,2989.70776,23.840,
1911.22754,47.598,2989.79932,23.840,
1911.31897,47.598,2989.89087,23.840,
1911.41052,46.598,2989.98242,23.840,
1911.50208,47.598,2990.07397,23.840,
1911.59363,47.598,2990.16553,23.840,
1911.68506,47.598,2990.25684,23.840,
1911.77661,47.598,2990.34839,23.840,
1911.86816,48.598,2990.43994,23.840,
1911.95972,47.598,2990.53149,23.840,
1912.05115,47.598,2990.62305,23.840,
1912.14270,48.598,2990.71460,23.840,
1912.23425,47.598,2990.80615,22.840,
1912.32568,47.598,2990.89771,23.840,
1912.41724,47.598,2990.98901,23.840,
1912.50879,47.598,2991.08057,23.840,
1912.60034,47.598,2991.17212,23.840,
1912.69177,47.598,2991.26367,23.840,
1912.78333,47.598,2991.35522,23.840,
1912.87488,47.598,2991.44678,23.840,
1912.96643,47.598,2991.53833,23.840,
1913.05786,47.598,2991.62964,23.840,
1913.14941,47.598,2991.72119,23.840,
1913.24097,47.598,2991.81274,23.840,
1913.33252,48.598,2991.90430,23.840,
1913.42395,46.598,2991.99585,23.840,
1913.51550,47.598,2992.08740,23.840,
1913.60706,47.598,2992.17896,23.840,
1913.69861,47.598,2992.27051,23.840,
1913.79004,46.598,2992.36182,23.840,
1913.88159,47.598,2992.45337,23.840,
1913.97314,47.598,2992.54492,23.840,
1914.06458,47.598,2992.63647,23.840,
1914.15613,47.598,2992.72803,23.840,
1914.24768,47.598,2992.81958,23.840,
1914.33923,47.598,2992.91113,23.840,
1914.43066,47.598,2993.00269,23.840,
1914.52222,47.598,2993.09399,23.840,
1914.61377,47.598,2993.18555,23.840,
1914.70532,47.598,2993.27710,23.840,
1914.79675,47.598,2993.36865,23.840,
1914.88831,47.598,2993.46021,23.840,
1914.97986,47.598,2993.55176,23.840,
1915.07141,47.598,2993.64331,23.840,
1915.16284,47.598,2993.73462,23.840,
1915.25439,48.598,2993.82617,23.840,
1915.34595,47.598,2993.91772,24.840,
1915.43750,47.598,2994.00928,24.840,
1915.52893,47.598,2994.10083,23.840,
1915.62048,47.598,2994.19238,23.840,
1915.71204,47.598,2994.28394,24.840,
1915.80347,47.598,2994.37549,24.840,
1915.89502,47.598,2994.46680,23.840,
1915.98657,47.598,2994.55835,24.840,
1916.07813,47.598,2994.64990,24.840,
1916.16956,48.598,2994.74146,24.840,
1916.26111,48.598,2994.83301,23.840,
1916.35266,47.598,2994.92456,23.840,
1916.44421,47.598,2995.01611,24.840,
1916.53564,47.598,2995.10767,24.840,
1916.62720,47.598,2995.19897,24.840,
1916.71875,47.598,2995.29053,24.840,
1916.81030,47.598,2995.38208,24.840,
1916.90173,47.598,2995.47363,24.840,
1916.99329,47.598,2995.56519,23.840,
1917.08484,47.598,2995.65674,24.840,
1917.17639,47.598,2995.74829,24.840,
1917.26782,47.598,2995.83960,24.840,
1917.35938,47.598,2995.93115,24.840,
1917.45093,48.598,2996.02271,24.840,
1917.54248,47.598,2996.11426,24.840,
1917.63391,47.598,2996.20581,24.840,
1917.72546,48.598,2996.29736,24.840,
1917.81702,47.598,2996.38892,24.840,
1917.90845,48.598,2996.48047,24.840,
1918.00000,48.598,2996.57178,23.840,
1918.09155,47.598,2996.66333,24.840,
1918.18311,48.598,2996.75488,24.840,
1918.27454,47.598,2996.84644,24.840,
1918.36609,48.598,2996.93799,25.840,
1918.45764,48.598,2997.02954,24.840,
1918.54919,48.598,2997.12109,25.840,
1918.64063,48.598,2997.21240,24.840,
1918.73218,47.598,2997.30396,25.840,
1918.82373,47.598,2997.39551,24.840,
1918.91528,47.598,2997.48706,24.840,
1919.00671,48.598,2997.57861,25.840,
1919.09827,48.598,2997.67017,24.840,
1919.18982,48.598,2997.76172,24.840,
1919.28137,47.598,2997.85327,24.840,
1919.37280,48.598,2997.94458,25.840,
1919.46436,48.598,2998.03613,24.840,
1919.55591,48.598,2998.12769,24.840,
1919.64734,47.598,2998.21924,25.840,
1919.73889,47.598,2998.31079,25.840,
1919.83044,48.598,2998.40234,25.840,
1919.92200,48.598,2998.49390,24.840,
1920.01343,47.598,2998.58545,25.840,
1920.10498,47.598,2998.67676,24.840,
1920.19653,47.598,2998.76831,25.840,
1920.28809,48.598,2998.85986,25.840,
1920.37952,48.598,2998.95142,24.840,
1920.47107,48.598,2999.04297,25.840,
1920.56262,48.598,2999.13452,25.840,
1920.65417,48.598,2999.22607,25.840,
1920.74561,48.598,2999.31738,25.840,
1920.83716,48.598,2999.40894,25.840,
1920.92871,48.598,2999.50049,25.840,
1921.02026,48.598,2999.59204,24.840,
1921.11169,48.598,2999.68359,24.840,
1921.20325,48.598,2999.77515,25.840,
1921.29480,48.598,2999.86670,25.840,
1921.38635,48.598,2999.95825,24.840,
1921.47778,48.598,3000.04956,25.840,
1921.56934,48.598,3000.14111,24.840,
1921.66089,48.598,3000.23267,24.840,
1921.75232,48.598,3000.32422,24.840,
1921.84387,48.598,3000.41577,25.840,
1921.93542,48.598,3000.50732,24.840,
1922.02698,48.598,3000.59888,25.840,
1922.11841,48.598,3000.69043,25.840,
1922.20996,48.598,3000.78174,25.840,
1922.30151,48.598,3000.87329,24.840,
1922.39307,49.598,3000.96484,24.840,
1922.48450,48.598,3001.05640,25.840,
1922.57605,48.598,3001.14795,24.840,
1922.66760,48.598,3001.23950,23.840,
1922.75916,48.598,3001.33105,24.840,
1922.85059,48.598,3001.42236,24.840,
1922.94214,48.598,3001.51392,24.840,
1923.03369,48.598,3001.60547,24.840,
1923.12524,48.598,3001.69702,24.840,
1923.21667,48.598,3001.78857,24.840,
1923.30823,48.598,3001.88013,24.840,
1923.39978,48.598,3001.97168,24.840,
1923.49121,48.598,3002.06323,25.840,
1923.58276,48.598,3002.15454,24.840,
1923.67432,49.598,3002.24609,24.840,
1923.76587,49.598,3002.33765,24.840,
1923.85730,48.598,3002.42920,25.840,
1923.94885,49.598,3002.52075,25.840,
1924.04041,49.598,3002.61230,25.840,
1924.13196,48.598,3002.70386,25.840,
1924.22339,49.598,3002.79517,26.840,
1924.31494,48.598,3002.88672,25.840,
1924.40649,48.598,3002.97827,25.840,
1924.49805,49.598,3003.06982,25.840,
1924.58948,48.598,3003.16138,25.840,
1924.68103,49.598,3003.25293,25.840,
1924.77258,48.598,3003.34448,25.840,
1924.86414,48.598,3003.43604,26.840,
1924.95557,49.598,3003.52734,26.840,
1925.04712,49.598,3003.61890,25.840,
1925.13867,48.598,3003.71045,25.840,
1925.23010,49.598,3003.80200,25.840,
1925.32166,49.598,3003.89355,25.840,
1925.41321,48.598,3003.98511,25.840,
1925.50476,49.598,3004.07666,25.840,
1925.59619,49.598,3004.16821,25.840,
1925.68774,49.598,3004.25952,25.840,
1925.77930,48.598,3004.35107,25.840,
1925.87085,48.598,3004.44263,25.840,
1925.96228,49.598,3004.53418,25.840,
1926.05383,48.598,3004.62573,25.840,
1926.14539,48.598,3004.71729,25.840,
1926.23694,49.598,3004.80884,25.840,
1926.32837,49.598,3004.90015,25.840,
1926.41992,48.598,3004.99170,26.840,
1926.51147,49.598,3005.08325,25.840,
1926.60303,49.598,3005.17480,25.840,
1926.69446,49.598,3005.26636,25.840,
1926.78601,49.598,3005.35791,25.840,
1926.87756,49.598,3005.44946,25.840,
1926.96912,49.598,3005.54102,25.840,
1927.06055,49.598,3005.63232,25.840,
1927.15210,49.598,3005.72388,26.840,
1927.24365,49.598,3005.81543,25.840,
1927.33508,49.598,3005.90698,25.840,
1927.42664,49.598,3005.99854,25.840,
1927.51819,49.598,3006.09009,25.840,
1927.60974,49.598,3006.18164,25.840,
1927.70117,49.598,3006.27319,26.840,
1927.79272,49.598,3006.36450,25.840,
1927.88428,49.598,3006.45605,25.840,
1927.97583,49.598,3006.54761,26.840,
1928.06726,50.598,3006.63916,26.840,
1928.15881,49.598,3006.73071,25.840,
1928.25037,49.598,3006.82227,26.840,
1928.34192,50.598,3006.91382,25.840,
1928.43335,49.598,3007.00513,25.840,
1928.52490,49.598,3007.09668,26.840,
1928.61646,49.598,3007.18823,26.840,
1928.70801,49.598,3007.27979,26.840,
1928.79944,49.598,3007.37134,26.840,
1928.89099,49.598,3007.46289,26.840,
1928.98254,50.598,3007.55444,26.840,
1929.07397,49.598,3007.64600,25.840,
1929.16553,49.598,3007.73730,26.840,
1929.25708,49.598,3007.82886,26.840,
1929.34863,49.598,3007.92041,26.840,
1929.44006,50.598,3008.01196,26.840,
1929.53162,49.598,3008.10352,26.840,
1929.62317,49.598,3008.19507,26.840,
1929.71472,49.598,3008.28662,26.840,
1929.80615,49.598,3008.37793,26.840,
1929.89771,49.598,3008.46948,26.840,
1929.98926,49.598,3008.56104,26.840,
1930.08081,49.598,3008.65259,27.840,
1930.17224,49.598,3008.74414,26.840,
1930.26379,49.598,3008.83569,26.840,
1930.35535,49.598,3008.92725,27.840,
1930.44690,49.598,3009.01880,26.840,
1930.53833,50.598,3009.11011,26.840,
1930.62988,49.598,3009.20166,26.840,
1930.72144,49.598,3009.29321,26.840,
1930.81299,50.598,3009.38477,26.840,
1930.90442,50.598,3009.47632,26.840,
1930.99597,49.598,3009.56787,26.840,
1931.08752,50.598,3009.65942,26.840,
1931.17896,50.598,3009.75098,26.840,
1931.27051,49.598,3009.84229,26.840,
1931.36206,48.598,3009.93384,26.840,
1931.45361,48.598,3010.02539,26.840,
1931.54504,48.598,3010.11694,27.840,
1931.63660,47.598,3010.20850,26.840,
1931.72815,47.598,3010.30005,26.840,
1931.81970,47.598,3010.39160,26.840,
1931.91113,47.598,3010.48291,26.840,
1932.00269,48.598,3010.57446,27.840,
1932.09424,49.598,3010.66602,26.840,
1932.18579,48.598,3010.75757,26.840,
1932.27722,50.598,3010.84912,26.840,
1932.36877,50.598,3010.94067,26.840,
1932.46033,50.598,3011.03223,26.840,
1932.55188,50.598,3011.12378,26.840,
1932.64331,50.598,3011.21509,26.840,
1932.73486,50.598,3011.30664,25.840,
1932.82642,50.598,3011.39819,26.840,
1932.91785,50.598,3011.48975,27.840,
1933.00940,50.598,3011.58130,27.840,
1933.10095,51.598,3011.67285,27.840,
1933.19250,50.598,3011.76440,27.840,
1933.28394,50.598,3011.85596,26.840,
1933.37549,50.598,3011.94727,27.840,
1933.46704,50.598,3012.03882,27.840,
1933.55859,50.598,3012.13037,27.840,
1933.65002,49.598,3012.22192,26.840,
1933.74158,50.598,3012.31348,27.840,
1933.83313,51.598,3012.40503,27.840,
1933.92468,50.598,3012.49658,27.840,
1934.01611,50.598,3012.58789,26.840,
1934.10767,50.598,3012.67944,27.840,
1934.19922,50.598,3012.77100,27.840,
1934.29077,50.598,3012.86255,26.840,
1934.38220,50.598,3012.95410,27.840,
1934.47375,50.598,3013.04565,28.840,
1934.56531,50.598,3013.13721,27.840,
1934.65674,50.598,3013.22876,27.840,
1934.74829,50.598,3013.32007,27.840,
1934.83984,51.598,3013.41162,27.840,
1934.93140,50.598,3013.50317,27.840,
1935.02283,50.598,3013.59473,27.840,
1935.11438,50.598,3013.68628,27.840,
1935.20593,50.598,3013.77783,27.840,
1935.29749,50.598,3013.86938,27.840,
1935.38892,51.598,3013.96094,27.840,
1935.48047,51.598,3014.05225,27.840,
1935.57202,50.598,3014.14380,27.840,
1935.66357,51.598,3014.23535,26.840,
1935.75500,50.598,3014.32690,26.840,
1935.84656,50.598,3014.41846,27.840,
1935.93811,51.598,3014.51001,28.840,
1936.02966,51.598,3014.60156,27.840,
1936.12109,51.598,3014.69287,27.840,
1936.21265,50.598,3014.78442,27.840,
1936.30420,50.598,3014.87598,28.840,
1936.39575,51.598,3014.96753,27.840,
1936.48718,50.598,3015.05908,27.840,
1936.57874,50.598,3015.15063,27.840,
1936.67029,51.598,3015.24219,27.840,
1936.76172,51.598,3015.33374,27.840,
1936.85327,50.598,3015.42505,27.840,
1936.94482,51.598,3015.51660,27.840,
1937.03638,51.598,3015.60815,27.840,
1937.12781,51.598,3015.69971,27.840,
1937.21936,51.598,3015.79126,27.840,
1937.31091,51.598,3015.88281,27.840,
1937.40247,51.598,3015.97437,28.840,
1937.49390,51.598,3016.06567,27.840,
1937.58545,51.598,3016.15723,27.840,
1937.67700,50.598,3016.24878,28.840,
1937.76855,51.598,3016.34033,28.840,
1937.85999,51.598,3016.43188,28.840,
1937.95154,51.598,3016.52344,27.840,
1938.04309,51.598,3016.61499,28.840,
1938.13464,51.598,3016.70654,28.840,
1938.22607,51.598,3016.79785,28.840,
1938.31763,51.598,3016.88940,28.840,
1938.40918,51.598,3016.98096,27.840,
1938.50061,51.598,3017.07251,27.840,
1938.59216,51.598,3017.16406,27.840,
1938.68372,51.598,3017.25562,28.840,
1938.77527,51.598,3017.34717,27.840,
1938.86670,51.598,3017.43872,27.840,
1938.95825,51.598,3017.53003,27.840,
1939.04980,51.598,3017.62158,27.840,
1939.14136,51.598,3017.71313,27.840,
1939.23279,51.598,3017.80469,27.840,
1939.32434,51.598,3017.89624,27.840,
1939.41589,51.598,3017.98779,28.840,
1939.50745,51.598,3018.07935,27.840,
1939.59888,51.598,3018.17065,27.840,
1939.69043,52.598,3018.26221,27.840,
1939.78198,51.598,3018.35376,27.840,
1939.87354,51.598,3018.44531,28.840,
1939.96497,51.598,3018.53687,28.840,
1940.05652,51.598,3018.62842,27.840,
1940.14807,51.598,3018.71997,27.840,
1940.23962,51.598,3018.81152,27.840,
1940.33105,51.598,3018.90283,28.840,
1940.42261,51.598,3018.99438,27.840,
1940.51416,51.598,3019.08594,27.840,
1940.60559,51.598,3019.17749,28.840,
1940.69714,52.598,3019.26904,27.840,
1940.78870,51.598,3019.36060,27.840,
1940.88025,52.598,3019.45215,28.840,
1940.97168,51.598,3019.54370,28.840,
1941.06323,52.598,3019.63501,28.840,
1941.15479,52.598,3019.72656,28.840,
1941.24634,51.598,3019.81812,28.840,
1941.33777,52.598,3019.90967,28.840,
1941.42932,52.598,3020.00122,28.840,
1941.52087,52.598,3020.09277,28.840,
1941.61243,51.598,3020.18433,28.840,
1941.70386,51.598,3020.27563,28.840,
1941.79541,52.598,3020.36719,29.840,
1941.88696,52.598,3020.45874,28.840,
1941.97852,51.598,3020.55029,29.840,
1942.06995,51.598,3020.64185,29.840,
1942.16150,52.598,3020.73340,28.840,
1942.25305,52.598,3020.82495,28.840,
1942.34448,51.598,3020.91650,29.840,
1942.43604,51.598,3021.00781,28.840,
1942.52759,52.598,3021.09937,28.840,
1942.61914,52.598,3021.19092,28.840,
1942.71057,51.598,3021.28247,28.840,
1942.80212,52.598,3021.37402,28.840,
1942.89368,52.598,3021.46558,28.840,
1942.98523,51.598,3021.55713,28.840,
1943.07666,52.598,3021.64844,28.840,
1943.16821,52.598,3021.73999,28.840,
1943.25977,52.598,3021.83154,29.840,
1943.35132,52.598,3021.92310,28.840,
1943.44275,52.598,3022.01465,28.840,
1943.53430,51.598,3022.10620,28.840,
1943.62585,51.598,3022.19775,28.840,
1943.71741,51.598,3022.28931,28.840,
1943.80884,51.598,3022.38062,28.840,
1943.90039,51.598,3022.47217,28.840,
1943.99194,52.598,3022.56372,28.840,
1944.08337,52.598,3022.65527,28.840,
1944.17493,52.598,3022.74683,28.840,
1944.26648,52.598,3022.83838,28.840,
1944.35803,52.598,3022.92993,28.840,
1944.44946,52.598,3023.02148,28.840,
1944.54102,52.598,3023.11279,28.840,
1944.63257,52.598,3023.20435,28.840,
1944.72412,52.598,3023.29590,28.840,
1944.81555,52.598,3023.38745,28.840,
1944.90710,52.598,3023.47900,28.840,
1944.99866,52.598,3023.57056,28.840,
1945.09021,52.598,3023.66211,29.840,
1945.18164,52.598,3023.75342,28.840,
1945.27319,52.598,3023.84497,28.840,
1945.36475,52.598,3023.93652,28.840,
1945.45630,52.598,3024.02808,28.840,
1945.54773,52.598,3024.11963,27.840,
1945.63928,52.598,3024.21118,28.840,
1945.73083,52.598,3024.30273,28.840,
1945.82239,52.598,3024.39429,28.840,
1945.91382,52.598,3024.48560,28.840,
1946.00537,52.598,3024.57715,28.840,
1946.09692,52.598,3024.66870,29.840,
1946.18835,52.598,3024.76025,29.840,
1946.27991,52.598,3024.85181,28.840,
1946.37146,52.598,3024.94336,29.840,
1946.46301,52.598,3025.03491,28.840,
1946.55444,52.598,3025.12646,29.840,
1946.64600,52.598,3025.21777,29.840,
1946.73755,52.598,3025.30933,28.840,
1946.82910,52.598,3025.40088,29.840,
1946.92053,51.598,3025.49243,28.840,
1947.01208,53.598,3025.58398,28.840,
1947.10364,52.598,3025.67554,28.840,
1947.19519,52.598,3025.76709,29.840,
1947.28662,52.598,3025.85840,29.840,
1947.37817,52.598,3025.94995,29.840,
1947.46973,52.598,3026.04150,29.840,
1947.56128,52.598,3026.13306,29.840,
1947.65271,53.598,3026.22461,29.840,
1947.74426,52.598,3026.31616,29.840,
1947.83582,52.598,3026.40771,28.840,
1947.92725,52.598,3026.49927,29.840,
1948.01880,52.598,3026.59058,28.840,
1948.11035,52.598,3026.68213,29.840,
1948.20190,52.598,3026.77368,29.840,
1948.29333,52.598,3026.86523,29.840,
1948.38489,52.598,3026.95679,29.840,
1948.47644,53.598,3027.04834,28.840,
1948.56799,52.598,3027.13989,28.840,
1948.65942,53.598,3027.23120,28.840,
1948.75098,52.598,3027.32275,29.840,
1948.84253,53.598,3027.41431,29.840,
1948.93408,53.598,3027.50586,29.840,
1949.02551,53.598,3027.59741,29.840,
1949.11707,53.598,3027.68896,29.840,
1949.20862,53.598,3027.78052,29.840,
1949.30017,53.598,3027.87207,29.840,
1949.39160,53.598,3027.96338,29.840,
1949.48315,53.598,3028.05493,29.840,
1949.57471,53.598,3028.14648,29.840,
1949.66626,53.598,3028.23804,28.840,
1949.75769,53.598,3028.32959,29.840,
1949.84924,53.598,3028.42114,28.840,
1949.94080,53.598,3028.51270,29.840,
1950.03223,53.598,3028.60425,29.840,
1950.12378,53.598,3028.69556,29.840,
1950.21533,53.598,3028.78711,29.840,
1950.30688,53.598,3028.87866,29.840,
1950.39832,53.598,3028.97021,29.840,
1950.48987,53.598,3029.06177,29.840,
1950.58142,53.598,3029.15332,29.840,
1950.67297,53.598,3029.24487,29.840,
1950.76440,53.598,3029.33618,29.840,
1950.85596,53.598,3029.42773,29.840,
1950.94751,53.598,3029.51929,29.840,
1951.03906,54.598,3029.61084,29.840,
1951.13049,54.598,3029.70239,29.840,
1951.22205,54.598,3029.79395,29.840,
1951.31360,54.598,3029.88550,29.840,
1951.40515,55.598,3029.97705,28.840,
1951.49658,54.598,3030.06836,29.840,
1951.58813,55.598,3030.15991,29.840,
1951.67969,55.598,3030.25146,29.840,
1951.77112,55.598,3030.34302,29.840,
1951.86267,54.598,3030.43457,29.840,
1951.95422,54.598,3030.52612,29.840,
1952.04578,54.598,3030.61768,30.840,
1952.13721,54.598,3030.70923,29.840,
1952.22876,54.598,3030.80054,30.840,
1952.32031,54.598,3030.89209,30.840,
1952.41187,54.598,3030.98364,30.840,
1952.50330,53.598,3031.07520,30.840,
1952.59485,54.598,3031.16675,30.840,
1952.68640,53.598,3031.25830,30.840,
1952.77795,53.598,3031.34985,30.840,
1952.86938,54.598,3031.44116,29.840,
1952.96094,53.598,3031.53271,29.840,
1953.05249,54.598,3031.62427,29.840,
1953.14404,54.598,3031.71582,30.840,
1953.23547,53.598,3031.80737,29.840,
1953.32703,53.598,3031.89893,29.840,
1953.41858,54.598,3031.99048,30.840,
1953.51001,54.598,3032.08203,30.840,
1953.60156,53.598,3032.17334,29.840,
1953.69312,53.598,3032.26489,29.840,
1953.78467,54.598,3032.35645,30.840,
1953.87610,53.598,3032.44800,29.840,
1953.96765,54.598,3032.53955,30.840,
1954.05920,53.598,3032.63110,30.840,
1954.15076,54.598,3032.72266,30.840,
1954.24219,54.598,3032.81421,30.840,
1954.33374,54.598,3032.90552,30.840,
1954.42529,54.598,3032.99707,30.840,
1954.51685,54.598,3033.08862,29.840,
1954.60828,54.598,3033.18018,30.840,
1954.69983,54.598,3033.27173,30.840,
1954.79138,54.598,3033.36328,30.840,
1954.88293,54.598,3033.45483,30.840,
1954.97437,54.598,3033.54614,31.840,
1955.06592,54.598,3033.63770,30.840,
1955.15747,53.598,3033.72925,30.840,
1955.24902,54.598,3033.82080,30.840,
1955.34045,54.598,3033.91235,30.840,
1955.43201,54.598,3034.00391,31.840,
1955.52356,54.598,3034.09546,30.840,
1955.61499,54.598,3034.18701,31.840,
1955.70654,54.598,3034.27832,30.840,
1955.79810,55.598,3034.36987,30.840,
1955.88965,54.598,3034.46143,30.840,
1955.98108,54.598,3034.55298,30.840,
1956.07263,54.598,3034.64453,30.840,
1956.16418,54.598,3034.73608,30.840,
1956.25574,54.598,3034.82764,30.840,
1956.34717,54.598,3034.91895,30.840,
1956.43872,54.598,3035.01050,30.840,
1956.53027,55.598,3035.10205,30.840,
1956.62183,55.598,3035.19360,30.840,
1956.71326,54.598,3035.28516,30.840,
1956.80481,54.598,3035.37671,30.840,
1956.89636,54.598,3035.46826,30.840,
1956.98792,54.598,3035.55981,30.840,
1957.07935,54.598,3035.65112,31.840,
1957.17090,55.598,3035.74268,31.840,
1957.26245,55.598,3035.83423,30.840,
1957.35388,54.598,3035.92578,31.840,
1957.44543,54.598,3036.01733,31.840,
1957.53699,55.598,3036.10889,30.840,
1957.62854,54.598,3036.20044,31.840,
1957.71997,55.598,3036.29199,31.840,
1957.81152,55.598,3036.38330,31.840,
1957.90308,54.598,3036.47485,31.840,
1957.99463,55.598,3036.56641,31.840,
1958.08606,55.598,3036.65796,31.840,
1958.17761,54.598,3036.74951,31.840,
1958.26917,54.598,3036.84106,31.840,
1958.36072,55.598,3036.93262,31.840,
1958.45215,55.598,3037.02393,31.840,
1958.54370,54.598,3037.11548,31.840,
1958.63525,54.598,3037.20703,32.840,
1958.72681,55.598,3037.29858,31.840,
1958.81824,55.598,3037.39014,31.840,
1958.90979,55.598,3037.48169,31.840,
1959.00134,55.598,3037.57324,31.840,
1959.09290,55.598,3037.66479,31.840,
1959.18433,55.598,3037.75610,31.840,
1959.27588,55.598,3037.84766,32.840,
1959.36743,55.598,3037.93921,32.840,
1959.45886,54.598,3038.03076,31.840,
1959.55042,55.598,3038.12231,32.840,
1959.64197,56.598,3038.21387,32.840,
1959.73352,55.598,3038.30542,31.840,
1959.82495,55.598,3038.39697,32.840,
1959.91650,55.598,3038.48828,31.840,
1960.00806,55.598,3038.57983,31.840,
1960.09961,55.598,3038.67139,31.840,
1960.19104,56.598,3038.76294,32.840,
1960.28259,55.598,3038.85449,31.840,
1960.37415,55.598,3038.94604,31.840,
1960.46570,55.598,3039.03760,31.840,
1960.55713,55.598,3039.12891,31.840,
1960.64868,55.598,3039.22046,31.840,
1960.74023,55.598,3039.31201,32.840,
1960.83179,56.598,3039.40356,32.840,
1960.92322,55.598,3039.49512,31.840,
1961.01477,55.598,3039.58667,31.840,
1961.10632,55.598,3039.67822,31.840,
1961.19775,55.598,3039.76978,31.840,
1961.28931,55.598,3039.86108,31.840,
1961.38086,55.598,3039.95264,32.840,
1961.47241,55.598,3040.04419,32.840,
1961.56384,56.598,3040.13574,32.840,
1961.65540,56.598,3040.22729,31.840,
1961.74695,55.598,3040.31885,32.840,
1961.83850,55.598,3040.41040,32.840,
1961.92993,55.598,3040.50171,32.840,
1962.02148,56.598,3040.59326,32.840,
1962.11304,56.598,3040.68481,32.840,
1962.20459,56.598,3040.77637,32.840,
1962.29602,55.598,3040.86792,32.840,
1962.38757,56.598,3040.95947,32.840,
1962.47913,55.598,3041.05103,32.840,
1962.57068,55.598,3041.14258,32.840,
1962.66211,56.598,3041.23389,32.840,
1962.75366,55.598,3041.32544,32.840,
1962.84521,55.598,3041.41699,32.840,
1962.93665,56.598,3041.50854,33.840,
1963.02820,57.598,3041.60010,32.840,
1963.11975,56.598,3041.69165,32.840,
1963.21130,56.598,3041.78320,32.840,
1963.30273,56.598,3041.87476,32.840,
1963.39429,56.598,3041.96606,32.840,
1963.48584,56.598,3042.05762,32.840,
1963.57739,56.598,3042.14917,32.840,
1963.66882,56.598,3042.24072,32.840,
1963.76038,56.598,3042.33228,33.840,
1963.85193,56.598,3042.42383,33.840,
1963.94348,56.598,3042.51538,33.840,
1964.03491,56.598,3042.60669,32.840,
1964.12646,56.598,3042.69824,32.840,
1964.21802,56.598,3042.78979,32.840,
1964.30957,56.598,3042.88135,32.840,
1964.40100,56.598,3042.97290,32.840,
1964.49255,56.598,3043.06445,32.840,
1964.58411,56.598,3043.15601,32.840,
1964.67566,56.598,3043.24756,32.840,
1964.76709,56.598,3043.33887,33.840,
1964.85864,56.598,3043.43042,32.840,
1964.95020,55.598,3043.52197,32.840,
1965.04163,56.598,3043.61353,33.840,
1965.13318,56.598,3043.70508,33.840,
1965.22473,56.598,3043.79663,33.840,
1965.31628,56.598,3043.88818,32.840,
1965.40771,56.598,3043.97974,32.840,
1965.49927,56.598,3044.07104,33.840,
1965.59082,56.598,3044.16260,32.840,
1965.68237,55.598,3044.25415,33.840,
1965.77380,56.598,3044.34570,33.840,
1965.86536,56.598,3044.43726,33.840,
1965.95691,56.598,3044.52881,33.840,
1966.04846,57.598,3044.62036,33.840,
1966.13989,56.598,3044.71167,32.840,
1966.23145,56.598,3044.80322,32.840,
1966.32300,57.598,3044.89478,32.840,
1966.41455,57.598,3044.98633,32.840,
1966.50598,57.598,3045.07788,33.840,
1966.59753,56.598,3045.16943,33.840,
1966.68909,56.598,3045.26099,33.840,
1966.78052,56.598,3045.35254,32.840,
1966.87207,56.598,3045.44385,33.840,
1966.96362,56.598,3045.53540,33.840,
1967.05518,56.598,3045.62695,33.840,
1967.14661,57.598,3045.71851,33.840,
1967.23816,57.598,3045.81006,33.840,
1967.32971,57.598,3045.90161,32.840,
1967.42126,57.598,3045.99316,33.840,
1967.51270,57.598,3046.08447,33.840,
1967.60425,57.598,3046.17603,33.840,
1967.69580,57.598,3046.26758,33.840,
1967.78735,57.598,3046.35913,33.840,
1967.87878,57.598,3046.45068,33.840,
1967.97034,57.598,3046.54224,33.840,
1968.06189,57.598,3046.63379,33.840,
1968.15344,57.598,3046.72534,34.840,
1968.24487,57.598,3046.81665,33.840,
1968.33643,57.598,3046.90820,33.840,
1968.42798,57.598,3046.99976,34.840,
1968.51953,56.598,3047.09131,33.840,
1968.61096,57.598,3047.18286,33.840,
1968.70251,57.598,3047.27441,34.840,
1968.79407,57.598,3047.36597,33.840,
1968.88550,57.598,3047.45752,33.840,
1968.97705,57.598,3047.54883,33.840,
1969.06860,57.598,3047.64038,33.840,
1969.16016,57.598,3047.73193,33.840,
1969.25159,57.598,3047.82349,33.840,
1969.34314,57.598,3047.91504,34.840,
1969.43469,57.598,3048.00659,33.840,
1969.52625,57.598,3048.09814,33.840,
1969.61768,57.598,3048.18945,34.840,
1969.70923,57.598,3048.28101,34.840,
1969.80078,57.598,3048.37256,33.840,
1969.89233,57.598,3048.46411,34.840,
1969.98376,58.598,3048.55566,34.840,
1970.07532,58.598,3048.64722,34.840,
1970.16687,58.598,3048.73877,33.840,
1970.25842,58.598,3048.83032,34.840,
1970.34985,58.598,3048.92163,34.840,
1970.44141,59.598,3049.01318,33.840,
1970.53296,58.598,3049.10474,34.840,
1970.62439,58.598,3049.19629,34.840,
1970.71594,58.598,3049.28784,34.840,
1970.80750,58.598,3049.37939,34.840,
1970.89905,58.598,3049.47095,34.840,
1970.99048,58.598,3049.56250,34.840,
1971.08203,57.598,3049.65381,34.840,
1971.17358,57.598,3049.74536,34.840,
1971.26514,58.598,3049.83691,33.840,
1971.35657,57.598,3049.92847,34.840,
1971.44812,57.598,3050.02002,34.840,
1971.53967,57.598,3050.11157,34.840,
1971.63123,57.598,3050.20313,33.840,
1971.72266,57.598,3050.29443,34.840,
1971.81421,57.598,3050.38599,34.840,
1971.90576,58.598,3050.47754,34.840,
1971.99731,57.598,3050.56909,34.840,
1972.08875,57.598,3050.66064,34.840,
1972.18030,57.598,3050.75220,34.840,
1972.27185,57.598,3050.84375,34.840,
1972.36328,57.598,3050.93530,34.840,
1972.45483,57.598,3051.02661,34.840,
1972.54639,57.598,3051.11816,35.840,
1972.63794,57.598,3051.20972,34.840,
1972.72937,57.598,3051.30127,35.840,
1972.82092,57.598,3051.39282,34.840,
1972.91248,57.598,3051.48438,34.840,
1973.00403,57.598,3051.57593,34.840,
1973.09546,58.598,3051.66748,35.840,
1973.18701,58.598,3051.75879,34.840,
1973.27856,57.598,3051.85034,35.840,
1973.37012,58.598,3051.94189,35.840,
1973.46155,58.598,3052.03345,35.840,
1973.55310,58.598,3052.12500,34.840,
1973.64465,58.598,3052.21655,35.840,
1973.73621,58.598,3052.30811,35.840,
1973.82764,58.598,3052.39941,34.840,
1973.91919,57.598,3052.49097,34.840,
1974.01074,58.598,3052.58252,35.840,
1974.10229,58.598,3052.67407,34.840,
1974.19373,58.598,3052.76563,35.840,
1974.28528,58.598,3052.85718,35.840,
1974.37683,58.598,3052.94873,36.840,
1974.46826,58.598,3053.04028,35.840,
1974.55981,58.598,3053.13159,36.840,
1974.65137,57.598,3053.22314,36.840,
1974.74292,58.598,3053.31470,36.840,
1974.83435,58.598,3053.40625,36.840,
1974.92590,58.598,3053.49780,36.840,
1975.01746,58.598,3053.58936,35.840,
1975.10901,58.598,3053.68091,35.840,
1975.20044,58.598,3053.77222,35.840,
1975.29199,58.598,3053.86377,35.840,
1975.38354,57.598,3053.95532,35.840,
1975.47510,58.598,3054.04688,36.840,
1975.56653,58.598,3054.13843,35.840,
1975.65808,58.598,3054.22998,35.840,
1975.74963,59.598,3054.32153,35.840,
1975.84119,58.598,3054.41309,35.840,
1975.93262,58.598,3054.50439,35.840,
1976.02417,57.598,3054.59595,35.840,
1976.11572,58.598,3054.68750,35.840,
1976.20715,58.598,3054.77905,35.840,
1976.29871,58.598,3054.87061,34.840,
1976.39026,58.598,3054.96216,35.840,
1976.48181,58.598,3055.05371,35.840,
1976.57324,59.598,3055.14526,34.840,
1976.66479,58.598,3055.23657,35.840,
1976.75635,58.598,3055.32813,34.840,
1976.84790,58.598,3055.41968,34.840,
1976.93933,58.598,3055.51123,35.840,
1977.03088,58.598,3055.60278,34.840,
1977.12244,58.598,3055.69434,34.840,
1977.21399,58.598,3055.78589,34.840,
1977.30542,58.598,3055.87720,34.840,
1977.39697,58.598,3055.96875,35.840,
1977.48853,58.598,3056.06030,34.840,
1977.58008,58.598,3056.15186,35.840,
1977.67151,59.598,3056.24341,35.840,
1977.76306,59.598,3056.33496,35.840,
1977.85461,57.598,3056.42651,35.840,
1977.94617,58.598,3056.51807,35.840,
1978.03760,58.598,3056.60938,35.840,
1978.12915,58.598,3056.70093,35.840,
1978.22070,58.598,3056.79248,35.840,
1978.31213,58.598,3056.88403,35.840,
1978.40369,59.598,3056.97559,36.840,
1978.49524,58.598,3057.06714,35.840,
1978.58679,58.598,3057.15869,35.840,
1978.67822,58.598,3057.25024,35.840,
1978.76978,58.598,3057.34155,35.840,
1978.86133,58.598,3057.43311,36.840,
1978.95288,58.598,3057.52466,36.840,
1979.04431,58.598,3057.61621,36.840,
1979.13586,58.598,3057.70776,36.840,
1979.22742,59.598,3057.79932,36.840,
1979.31897,58.598,3057.89087,36.840,
1979.41040,58.598,3057.98218,36.840,
1979.50195,59.598,3058.07373,36.840,
1979.59351,59.598,3058.16528,35.840,
1979.68506,59.598,3058.25684,36.840,
1979.77649,58.598,3058.34839,36.840,
1979.86804,59.598,3058.43994,36.840,
1979.95959,59.598,3058.53149,36.840,
1980.05103,59.598,3058.62305,36.840,
1980.14258,59.598,3058.71436,36.840,
1980.23413,58.598,3058.80591,36.840,
1980.32568,59.598,3058.89746,36.840,
1980.41711,59.598,3058.98901,36.840,
1980.50867,58.598,3059.08057,36.840,
1980.60022,59.598,3059.17212,36.840,
1980.69177,59.598,3059.26367,36.840,
1980.78320,59.598,3059.35498,36.840,
1980.87476,59.598,3059.44653,36.840,
1980.96631,59.598,3059.53809,36.840,
1981.05786,59.598,3059.62964,36.840,
1981.14929,59.598,3059.72119,36.840,
1981.24084,59.598,3059.81274,36.840,
1981.33240,59.598,3059.90430,37.840,
1981.42395,59.598,3059.99585,36.840,
1981.51538,58.598,3060.08716,36.840,
1981.60693,59.598,3060.17871,36.840,
1981.69849,59.598,3060.27026,36.840,
1981.78992,59.598,3060.36182,36.840,
1981.88147,59.598,3060.45337,36.840,
1981.97302,59.598,3060.54492,37.840,
1982.06458,59.598,3060.63647,36.840,
1982.15601,59.598,3060.72803,36.840,
1982.24756,59.598,3060.81934,37.840,
1982.33911,59.598,3060.91089,36.840,
1982.43066,59.598,3061.00244,36.840,
1982.52209,59.598,3061.09399,36.840,
1982.61365,59.598,3061.18555,37.840,
1982.70520,59.598,3061.27710,36.840,
1982.79675,59.598,3061.36865,37.840,
1982.88818,59.598,3061.45996,37.840,
1982.97974,59.598,3061.55151,36.840,
1983.07129,59.598,3061.64307,36.840,
1983.16284,59.598,3061.73462,37.840,
1983.25427,59.598,3061.82617,37.840,
1983.34583,59.598,3061.91772,37.840,
1983.43738,59.598,3062.00928,36.840,
1983.52893,59.598,3062.10083,37.840,
1983.62036,60.598,3062.19214,36.840,
1983.71191,59.598,3062.28369,36.840,
1983.80347,59.598,3062.37524,36.840,
1983.89490,59.598,3062.46680,36.840,
1983.98645,59.598,3062.55835,37.840,
1984.07800,59.598,3062.64990,37.840,
1984.16956,59.598,3062.74146,37.840,
1984.26099,59.598,3062.83301,37.840,
1984.35254,59.598,3062.92432,37.840,
1984.44409,59.598,3063.01587,37.840,
1984.53564,59.598,3063.10742,37.840,
1984.62708,59.598,3063.19897,37.840,
1984.71863,59.598,3063.29053,37.840,
1984.81018,59.598,3063.38208,36.840,
1984.90173,59.598,3063.47363,37.840,
1984.99316,59.598,3063.56494,37.840,
1985.08472,60.598,3063.65649,37.840,
1985.17627,59.598,3063.74805,36.840,
1985.26782,59.598,3063.83960,36.840,
1985.35925,60.598,3063.93115,37.840,
1985.45081,59.598,3064.02271,37.840,
1985.54236,60.598,3064.11426,37.840,
1985.63379,59.598,3064.20581,37.840,
1985.72534,60.598,3064.29712,37.840,
1985.81689,59.598,3064.38867,37.840,
1985.90845,59.598,3064.48022,37.840,
1985.99988,59.598,3064.57178,37.840,
1986.09143,59.598,3064.66333,37.840,
1986.18298,59.598,3064.75488,37.840,
1986.27454,60.598,3064.84644,37.840,
1986.36597,60.598,3064.93774,37.840,
1986.45752,60.598,3065.02930,37.840,
1986.54907,61.598,3065.12085,37.840,
1986.64063,60.598,3065.21240,37.840,
1986.73206,60.598,3065.30396,37.840,
1986.82361,60.598,3065.39551,37.840,
1986.91516,60.598,3065.48706,37.840,
1987.00671,59.598,3065.57861,37.840,
1987.09814,59.598,3065.66992,37.840,
1987.18970,60.598,3065.76147,38.840,
1987.28125,60.598,3065.85303,37.840,
1987.37268,59.598,3065.94458,37.840,
1987.46423,59.598,3066.03613,37.840,
1987.55579,60.598,3066.12769,37.840,
1987.64734,60.598,3066.21924,37.840,
1987.73877,60.598,3066.31079,37.840,
1987.83032,59.598,3066.40210,38.840,
1987.92188,60.598,3066.49365,37.840,
1988.01343,60.598,3066.58521,38.840,
1988.10486,60.598,3066.67676,38.840,
1988.19641,61.598,3066.76831,37.840,
1988.28796,59.598,3066.85986,37.840,
1988.37952,60.598,3066.95142,38.840,
1988.47095,60.598,3067.04272,37.840,
1988.56250,60.598,3067.13428,38.840,
1988.65405,60.598,3067.22583,39.840,
1988.74561,61.598,3067.31738,38.840,
1988.83704,62.598,3067.40894,37.840,
1988.92859,62.598,3067.50049,38.840,
1989.02014,63.598,3067.59204,38.840,
1989.11169,63.598,3067.68359,38.840,
1989.20313,63.598,3067.77490,38.840,
1989.29468,63.598,3067.86646,38.840,
1989.38623,63.598,3067.95801,38.840,
1989.47766,63.598,3068.04956,37.840,
1989.56921,62.598,3068.14111,38.840,
1989.66077,63.598,3068.23267,38.840,
1989.75232,62.598,3068.32422,37.840,
1989.84375,62.598,3068.41577,38.840,
1989.93530,62.598,3068.50708,38.840,
1990.02686,61.598,3068.59863,38.840,
1990.11841,61.598,3068.69019,38.840,
1990.20984,61.598,3068.78174,38.840,
1990.30139,61.598,3068.87329,38.840,
1990.39294,61.598,3068.96484,38.840,
1990.48450,60.598,3069.05640,38.840,
1990.57593,61.598,3069.14771,38.840,
1990.66748,60.598,3069.23926,38.840,
1990.75903,60.598,3069.33081,38.840,
1990.85059,60.598,3069.42236,38.840,
1990.94202,61.598,3069.51392,38.840,
1991.03357,60.598,3069.60547,38.840,
1991.12512,60.598,3069.69702,38.840,
1991.21655,60.598,3069.78857,38.840,
1991.30811,61.598,3069.87988,38.840,
1991.39966,61.598,3069.97144,38.840,
1991.49121,60.598,3070.06299,39.840,
1991.58264,61.598,3070.15454,39.840,
1991.67419,61.598,3070.24609,39.840,
1991.76575,60.598,3070.33765,39.840,
1991.85730,61.598,3070.42920,39.840,
1991.94873,61.598,3070.52075,38.840,
1992.04028,60.598,3070.61206,38.840,
1992.13184,61.598,3070.70361,38.840,
1992.22339,60.598,3070.79517,38.840,
1992.31482,61.598,3070.88672,38.840,
1992.40637,61.598,3070.97827,39.840,
1992.49792,61.598,3071.06982,39.840,
1992.58948,61.598,3071.16138,38.840,
1992.68091,61.598,3071.25269,39.840,
1992.77246,61.598,3071.34424,39.840,
1992.86401,61.598,3071.43579,39.840,
1992.95557,60.598,3071.52734,39.840,
1993.04700,61.598,3071.61890,39.840,
1993.13855,61.598,3071.71045,39.840,
1993.23010,61.598,3071.80200,39.840,
1993.32153,61.598,3071.89355,39.840,
1993.41309,61.598,3071.98486,39.840,
1993.50464,61.598,3072.07642,39.840,
1993.59619,60.598,3072.16797,39.840,
1993.68762,61.598,3072.25952,39.840,
1993.77917,61.598,3072.35107,39.840,
1993.87073,61.598,3072.44263,39.840,
1993.96228,61.598,3072.53418,39.840,
1994.05371,61.598,3072.62549,39.840,
1994.14526,61.598,3072.71704,39.840,
1994.23682,61.598,3072.80859,39.840,
1994.32837,62.598,3072.90015,39.840,
1994.41980,61.598,3072.99170,39.840,
1994.51135,61.598,3073.08325,40.840,
1994.60291,62.598,3073.17480,40.840,
1994.69446,61.598,3073.26636,39.840,
1994.78589,61.598,3073.35767,40.840,
1994.87744,61.598,3073.44922,40.840,
1994.96899,61.598,3073.54077,39.840,
1995.06042,61.598,3073.63232,40.840,
1995.15198,61.598,3073.72388,40.840,
1995.24353,61.598,3073.81543,39.840,
1995.33508,61.598,3073.90698,40.840,
1995.42651,61.598,3073.99854,40.840,
1995.51807,61.598,3074.08984,40.840,
1995.60962,62.598,3074.18140,40.840,
1995.70117,61.598,3074.27295,40.840,
1995.79260,61.598,3074.36450,40.840,
1995.88416,61.598,3074.45605,41.840,
1995.97571,61.598,3074.54761,41.840,
1996.06726,61.598,3074.63916,40.840,
1996.15869,61.598,3074.73047,40.840,
1996.25024,61.598,3074.82202,40.840,
1996.34180,62.598,3074.91357,41.840,
1996.43335,62.598,3075.00513,40.840,
1996.52478,62.598,3075.09668,40.840,
1996.61633,62.598,3075.18823,41.840,
1996.70789,62.598,3075.27979,40.840,
1996.79932,62.598,3075.37134,40.840,
1996.89087,61.598,3075.46265,40.840,
1996.98242,62.598,3075.55420,40.840,
1997.07397,61.598,3075.64575,40.840,
1997.16541,61.598,3075.73730,40.840,
1997.25696,61.598,3075.82886,40.840,
1997.34851,62.598,3075.92041,40.840,
1997.44006,62.598,3076.01196,41.840,
1997.53149,61.598,3076.10352,40.840,
1997.62305,61.598,3076.19482,40.840,
1997.71460,61.598,3076.28638,40.840,
1997.80615,61.598,3076.37793,40.840,
1997.89758,61.598,3076.46948,40.840,
1997.98914,62.598,3076.56104,40.840,
1998.08069,61.598,3076.65259,40.840,
1998.17224,61.598,3076.74414,40.840,
1998.26367,62.598,3076.83545,40.840,
1998.35522,62.598,3076.92700,40.840,
1998.44678,61.598,3077.01855,40.840,
1998.53833,62.598,3077.11011,40.840,
1998.62976,62.598,3077.20166,40.840,
1998.72131,62.598,3077.29321,41.840,
1998.81287,61.598,3077.38477,40.840,
1998.90430,62.598,3077.47632,41.840,
1998.99585,61.598,3077.56763,41.840,
1999.08740,62.598,3077.65918,40.840,
1999.17896,62.598,3077.75073,40.840,
1999.27039,62.598,3077.84229,40.840,
1999.36194,62.598,3077.93384,40.840,
1999.45349,62.598,3078.02539,40.840,
1999.54504,62.598,3078.11694,40.840,
1999.63647,62.598,3078.20825,40.840,
1999.72803,63.598,3078.29980,41.840,
1999.81958,62.598,3078.39136,40.840,
1999.91113,62.598,3078.48291,40.840,
2000.00256,62.598,3078.57446,41.840,
2000.09412,62.598,3078.66602,40.840,
2000.18567,62.598,3078.75757,40.840,
2000.27722,62.598,3078.84912,40.840,
2000.36865,63.598,3078.94043,41.840,
2000.46021,63.598,3079.03198,41.840,
2000.55176,62.598,3079.12354,40.840,
2000.64319,62.598,3079.21509,40.840,
2000.73474,62.598,3079.30664,41.840,
2000.82629,62.598,3079.39819,41.840,
2000.91785,62.598,3079.48975,40.840,
2001.00928,62.598,3079.58130,41.840,
2001.10083,62.598,3079.67261,40.840,
2001.19238,63.598,3079.76416,41.840,
2001.28394,63.598,3079.85571,41.840,
2001.37537,63.598,3079.94727,40.840,
2001.46692,62.598,3080.03882,41.840,
2001.55847,62.598,3080.13037,41.840,
2001.65002,63.598,3080.22192,40.840,
2001.74146,63.598,3080.31323,41.840,
2001.83301,63.598,3080.40479,41.840,
2001.92456,62.598,3080.49634,41.840,
2002.01611,62.598,3080.58789,41.840,
2002.10754,63.598,3080.67944,41.840,
2002.19910,63.598,3080.77100,41.840,
2002.29065,62.598,3080.86255,41.840,
2002.38220,62.598,3080.95410,41.840,
2002.47363,63.598,3081.04541,41.840,
2002.56519,63.598,3081.13696,41.840,
2002.65674,63.598,3081.22852,41.840,
2002.74817,63.598,3081.32007,41.840,
2002.83972,62.598,3081.41162,41.840,
2002.93127,62.598,3081.50317,41.840,
2003.02283,63.598,3081.59473,41.840,
2003.11426,63.598,3081.68628,41.840,
2003.20581,63.598,3081.77759,41.840,
2003.29736,63.598,3081.86914,41.840,
2003.38892,63.598,3081.96069,41.840,
2003.48035,62.598,3082.05225,41.840,
2003.57190,63.598,3082.14380,41.840,
2003.66345,62.598,3082.23535,41.840,
2003.75500,63.598,3082.32690,42.840,
2003.84644,63.598,3082.41821,41.840,
2003.93799,62.598,3082.50977,41.840,
2004.02954,63.598,3082.60132,42.840,
2004.12109,63.598,3082.69287,41.840,
2004.21252,63.598,3082.78442,41.840,
2004.30408,63.598,3082.87598,41.840,
2004.39563,63.598,3082.96753,41.840,
2004.48706,63.598,3083.05908,41.840,
2004.57861,63.598,3083.15039,41.840,
2004.67017,63.598,3083.24194,41.840,
2004.76172,63.598,3083.33350,42.840,
2004.85315,63.598,3083.42505,41.840,
2004.94470,63.598,3083.51660,41.840,
2005.03625,63.598,3083.60815,41.840,
2005.12781,63.598,3083.69971,42.840,
2005.21924,63.598,3083.79102,42.840,
2005.31079,63.598,3083.88257,42.840,
2005.40234,63.598,3083.97412,41.840,
2005.49390,63.598,3084.06567,42.840,
2005.58533,64.598,3084.15723,42.840,
2005.67688,64.598,3084.24878,41.840,
2005.76843,64.598,3084.34033,42.840,
2005.85999,64.598,3084.43188,42.840,
2005.95142,64.598,3084.52319,41.840,
2006.04297,64.598,3084.61475,42.840,
2006.13452,64.598,3084.70630,42.840,
2006.22595,65.598,3084.79785,42.840,
2006.31750,64.598,3084.88940,41.840,
2006.40906,64.598,3084.98096,42.840,
2006.50061,64.598,3085.07251,42.840,
2006.59204,64.598,3085.16406,42.840,
2006.68359,64.598,3085.25537,42.840,
2006.77515,64.598,3085.34692,42.840,
2006.86670,64.598,3085.43848,42.840,
2006.95813,64.598,3085.53003,41.840,
2007.04968,64.598,3085.62158,41.840,
2007.14124,64.598,3085.71313,41.840,
2007.23279,64.598,3085.80469,42.840,
2007.32422,63.598,3085.89600,41.840,
2007.41577,63.598,3085.98755,42.840,
2007.50732,63.598,3086.07910,42.840,
2007.59888,63.598,3086.17065,41.840,
2007.69031,64.598,3086.26221,42.840,
2007.78186,64.598,3086.35376,42.840,
2007.87341,63.598,3086.44531,42.840,
2007.96497,63.598,3086.53687,42.840,
2008.05640,63.598,3086.62817,42.840,
2008.14795,64.598,3086.71973,42.840,
2008.23950,64.598,3086.81128,42.840,
2008.33093,64.598,3086.90283,42.840,
2008.42249,64.598,3086.99438,42.840,
2008.51404,65.598,3087.08594,42.840,
2008.60559,65.598,3087.17749,42.840,
2008.69702,65.598,3087.26904,42.840,
2008.78857,65.598,3087.36035,42.840,
2008.88013,65.598,3087.45190,42.840,
2008.97168,65.598,3087.54346,42.840,
2009.06311,65.598,3087.63501,42.840,
2009.15466,65.598,3087.72656,43.840,
2009.24622,65.598,3087.81812,42.840,
2009.33777,64.598,3087.90967,42.840,
2009.42920,64.598,3088.00098,42.840,
2009.52075,64.598,3088.09253,43.840,
2009.61230,64.598,3088.18408,42.840,
2009.70386,63.598,3088.27563,42.840,
2009.79529,64.598,3088.36719,43.840,
2009.88684,64.598,3088.45874,43.840,
2009.97839,64.598,3088.55029,42.840,
2010.06982,64.598,3088.64185,43.840,
2010.16138,64.598,3088.73315,43.840,
2010.25293,64.598,3088.82471,43.840,
2010.34448,64.598,3088.91626,43.840,
2010.43591,64.598,3089.00781,43.840,
2010.52747,65.598,3089.09937,43.840,
2010.61902,64.598,3089.19092,44.840,
2010.71057,64.598,3089.28247,43.840,
2010.80200,65.598,3089.37378,44.840,
2010.89355,65.598,3089.46533,43.840,
2010.98511,64.598,3089.55688,43.840,
2011.07666,65.598,3089.64844,43.840,
2011.16809,65.598,3089.73999,43.840,
2011.25964,64.598,3089.83154,43.840,
2011.35120,65.598,3089.92310,43.840,
2011.44275,65.598,3090.01465,43.840,
2011.53418,64.598,3090.10596,43.840,
2011.62573,65.598,3090.19751,43.840,
2011.71729,65.598,3090.28906,43.840,
2011.80884,65.598,3090.38062,42.840,
2011.90027,64.598,3090.47217,43.840,
2011.99182,65.598,3090.56372,43.840,
2012.08337,64.598,3090.65527,43.840,
2012.17480,65.598,3090.74683,43.840,
2012.26636,65.598,3090.83813,44.840,
2012.35791,65.598,3090.92969,43.840,
2012.44946,65.598,3091.02124,43.840,
2012.54089,64.598,3091.11279,43.840,
2012.63245,65.598,3091.20435,43.840,
2012.72400,65.598,3091.29590,43.840,
2012.81555,65.598,3091.38745,43.840,
2012.90698,65.598,3091.47876,43.840,
2012.99854,65.598,3091.57031,44.840,
2013.09009,64.598,3091.66187,43.840,
2013.18164,65.598,3091.75342,44.840,
2013.27307,65.598,3091.84497,44.840,
2013.36462,65.598,3091.93652,44.840,
2013.45618,65.598,3092.02808,44.840,
2013.54773,65.598,3092.11963,45.840,
2013.63916,64.598,3092.21094,44.840,
2013.73071,65.598,3092.30249,44.840,
2013.82227,65.598,3092.39404,44.840,
2013.91370,65.598,3092.48560,44.840,
2014.00525,65.598,3092.57715,44.840,
2014.09680,64.598,3092.66870,44.840,
2014.18835,65.598,3092.76025,44.840,
2014.27979,65.598,3092.85181,44.840,
2014.37134,65.598,3092.94312,44.840,
2014.46289,65.598,3093.03467,43.840,
2014.55444,65.598,3093.12622,43.840,
2014.64587,65.598,3093.21777,43.840,
2014.73743,65.598,3093.30933,44.840,
2014.82898,65.598,3093.40088,44.840,
2014.92053,65.598,3093.49243,43.840,
2015.01196,66.598,3093.58374,44.840,
2015.10352,66.598,3093.67529,44.840,
2015.19507,65.598,3093.76685,44.840,
2015.28662,66.598,3093.85840,44.840,
2015.37805,65.598,3093.94995,44.840,
2015.46960,65.598,3094.04150,44.840,
2015.56116,65.598,3094.13306,43.840,
2015.65259,65.598,3094.22461,44.840,
2015.74414,66.598,3094.31592,44.840,
2015.83569,66.598,3094.40747,44.840,
2015.92725,65.598,3094.49902,44.840,
2016.01868,65.598,3094.59058,44.840,
2016.11023,65.598,3094.68213,44.840,
2016.20178,65.598,3094.77368,44.840,
2016.29333,66.598,3094.86523,44.840,
2016.38477,65.598,3094.95679,44.840,
2016.47632,66.598,3095.04810,44.840,
2016.56787,66.598,3095.13965,44.840,
2016.65942,66.598,3095.23120,44.840,
2016.75085,65.598,3095.32275,44.840,
2016.84241,65.598,3095.41431,45.840,
2016.93396,66.598,3095.50586,44.840,
2017.02551,65.598,3095.59741,44.840,
2017.11694,66.598,3095.68872,44.840,
2017.20850,66.598,3095.78027,45.840,
2017.30005,66.598,3095.87183,44.840,
2017.39160,66.598,3095.96338,44.840,
2017.48303,66.598,3096.05493,44.840,
2017.57458,66.598,3096.14648,44.840,
2017.66614,66.598,3096.23804,44.840,
2017.75757,66.598,3096.32959,45.840,
2017.84912,66.598,3096.42090,44.840,
2017.94067,66.598,3096.51245,45.840,
2018.03223,66.598,3096.60400,44.840,
2018.12366,66.598,3096.69556,44.840,
2018.21521,66.598,3096.78711,45.840,
2018.30676,66.598,3096.87866,45.840,
2018.39832,66.598,3096.97021,44.840,
2018.48975,66.598,3097.06152,44.840,
2018.58130,66.598,3097.15308,44.840,
2018.67285,66.598,3097.24463,45.840,
2018.76440,67.598,3097.33618,44.840,
2018.85583,66.598,3097.42773,44.840,
2018.94739,66.598,3097.51929,44.840,
2019.03894,66.598,3097.61084,45.840,
2019.13049,66.598,3097.70239,45.840,
2019.22192,66.598,3097.79370,44.840,
2019.31348,66.598,3097.88525,45.840,
2019.40503,66.598,3097.97681,45.840,
2019.49646,66.598,3098.06836,44.840,
2019.58801,66.598,3098.15991,45.840,
2019.67957,66.598,3098.25146,45.840,
2019.77112,66.598,3098.34302,45.840,
2019.86255,66.598,3098.43457,45.840,
2019.95410,66.598,3098.52588,45.840,
2020.04565,66.598,3098.61743,45.840,
2020.13721,66.598,3098.70898,44.840,
2020.22864,67.598,3098.80054,45.840,
2020.32019,66.598,3098.89209,45.840,
2020.41174,67.598,3098.98364,44.840,
2020.50330,66.598,3099.07520,44.840,
2020.59473,66.598,3099.16650,44.840,
2020.68628,67.598,3099.25806,45.840,
2020.77783,66.598,3099.34961,45.840,
2020.86938,66.598,3099.44116,45.840,
2020.96082,66.598,3099.53271,45.840,
2021.05237,66.598,3099.62427,45.840,
2021.14392,67.598,3099.71582,45.840,
2021.23547,66.598,3099.80737,45.840,
2021.32690,66.598,3099.89868,45.840,
2021.41846,66.598,3099.99023,45.840,
2021.51001,66.598,3100.08179,45.840,
2021.60144,66.598,3100.17334,45.840,
2021.69299,66.598,3100.26489,45.840,
2021.78455,67.598,3100.35645,45.840,
2021.87610,67.598,3100.44800,45.840,
2021.96753,66.598,3100.53955,45.840,
2022.05908,67.598,3100.63086,45.840,
2022.15063,67.598,3100.72241,45.840,
2022.24219,67.598,3100.81396,45.840,
2022.33362,66.598,3100.90552,45.840,
2022.42517,66.598,3100.99707,46.840,
2022.51672,67.598,3101.08862,45.840,
2022.60828,66.598,3101.18018,45.840,
2022.69971,67.598,3101.27148,46.840,
2022.79126,67.598,3101.36304,45.840,
2022.88281,67.598,3101.45459,45.840,
2022.97437,67.598,3101.54614,45.840,
2023.06580,67.598,3101.63770,46.840,
2023.15735,67.598,3101.72925,45.840,
2023.24890,67.598,3101.82080,45.840,
2023.34033,67.598,3101.91235,46.840,
2023.43188,67.598,3102.00366,45.840,
2023.52344,67.598,3102.09521,45.840,
2023.61499,67.598,3102.18677,46.840,
2023.70642,67.598,3102.27832,45.840,
2023.79797,67.598,3102.36987,46.840,
2023.88953,67.598,3102.46143,46.840,
2023.98108,67.598,3102.55298,46.840,
2024.07251,67.598,3102.64429,45.840,
2024.16406,67.598,3102.73584,46.840,
2024.25562,67.598,3102.82739,46.840,
2024.34717,67.598,3102.91895,46.840,
2024.43860,67.598,3103.01050,46.840,
2024.53015,67.598,3103.10205,46.840,
2024.62170,68.598,3103.19360,45.840,
2024.71326,67.598,3103.28516,46.840,
2024.80469,67.598,3103.37646,46.840,
2024.89624,67.598,3103.46802,46.840,
2024.98779,67.598,3103.55957,46.840,
2025.07922,67.598,3103.65112,46.840,
2025.17078,67.598,3103.74268,46.840,
2025.26233,67.598,3103.83423,46.840,
2025.35388,67.598,3103.92578,46.840,
2025.44531,67.598,3104.01733,47.840,
2025.53687,67.598,3104.10864,46.840,
2025.62842,67.598,3104.20020,47.840,
2025.71997,67.598,3104.29175,46.840,
2025.81140,67.598,3104.38330,46.840,
2025.90295,67.598,3104.47485,46.840,
2025.99451,67.598,3104.56641,46.840,
2026.08606,68.598,3104.65796,46.840,
2026.17749,68.598,3104.74927,46.840,
2026.26904,67.598,3104.84082,46.840,
2026.36060,68.598,3104.93237,47.840,
2026.45215,68.598,3105.02393,47.840,
2026.54358,67.598,3105.11548,46.840,
2026.63513,68.598,3105.20703,47.840,
2026.72668,68.598,3105.29858,47.840,
2026.81824,68.598,3105.39014,47.840,
2026.90967,67.598,3105.48145,47.840,
2027.00122,67.598,3105.57300,47.840,
2027.09277,65.598,3105.66455,46.840,
2027.18420,65.598,3105.75610,47.840,
2027.27576,65.598,3105.84766,47.840,
2027.36731,64.598,3105.93921,47.840,
2027.45886,65.598,3106.03076,47.840,
2027.55029,66.598,3106.12231,47.840,
2027.64185,65.598,3106.21362,47.840,
2027.73340,66.598,3106.30518,47.840,
2027.82495,66.598,3106.39673,46.840,
2027.91638,66.598,3106.48828,47.840,
2028.00793,67.598,3106.57983,47.840,
2028.09949,67.598,3106.67139,46.840,
2028.19104,67.598,3106.76294,47.840,
2028.28247,68.598,3106.85425,47.840,
2028.37402,68.598,3106.94580,47.840,
2028.46558,68.598,3107.03735,47.840,
2028.55713,68.598,3107.12891,47.840,
2028.64856,68.598,3107.22046,47.840,
2028.74011,68.598,3107.31201,47.840,
2028.83167,69.598,3107.40356,47.840,
2028.92310,69.598,3107.49512,47.840,
2029.01465,69.598,3107.58643,46.840,
2029.10620,69.598,3107.67798,47.840,
2029.19775,68.598,3107.76953,47.840,
2029.28918,69.598,3107.86108,46.840,
2029.38074,68.598,3107.95264,47.840,
2029.47229,69.598,3108.04419,47.840,
2029.56384,68.598,3108.13574,47.840,
2029.65527,68.598,3108.22705,47.840,
2029.74683,68.598,3108.31860,47.840,
2029.83838,69.598,3108.41016,47.840,
2029.92993,68.598,3108.50171,47.840,
2030.02136,68.598,3108.59326,47.840,
2030.11292,69.598,3108.68481,47.840,
2030.20447,69.598,3108.77637,47.840,
2030.29602,68.598,3108.86792,47.840,
2030.38745,68.598,3108.95923,47.840,
2030.47900,69.598,3109.05078,48.840,
2030.57056,69.598,3109.14233,47.840,
2030.66211,69.598,3109.23389,47.840,
2030.75354,69.598,3109.32544,47.840,
2030.84509,69.598,3109.41699,47.840,
2030.93665,69.598,3109.50854,47.840,
2031.02808,69.598,3109.60010,47.840,
2031.11963,69.598,3109.69141,48.840,
2031.21118,69.598,3109.78296,48.840,
2031.30273,69.598,3109.87451,48.840,
2031.39417,69.598,3109.96606,48.840,
2031.48572,69.598,3110.05762,48.840,
2031.57727,69.598,3110.14917,49.840,
2031.66882,69.598,3110.24072,48.840,
2031.76025,69.598,3110.33203,49.840,
2031.85181,69.598,3110.42358,49.840,
2031.94336,69.598,3110.51514,48.840,
2032.03491,69.598,3110.60669,48.840,
2032.12634,69.598,3110.69824,48.840,
2032.21790,69.598,3110.78979,48.840,
2032.30945,69.598,3110.88135,48.840,
2032.40100,69.598,3110.97290,48.840,
2032.49243,69.598,3111.06421,48.840,
2032.58398,69.598,3111.15576,49.840,
2032.67554,68.598,3111.24731,48.840,
2032.76697,68.598,3111.33887,48.840,
2032.85852,69.598,3111.43042,48.840,
2032.95007,69.598,3111.52197,47.840,
2033.04163,68.598,3111.61353,47.840,
2033.13306,69.598,3111.70508,48.840,
2033.22461,69.598,3111.79639,48.840,
2033.31616,69.598,3111.88794,47.840,
2033.40771,69.598,3111.97949,48.840,
2033.49915,69.598,3112.07104,48.840,
2033.59070,69.598,3112.16260,47.840,
2033.68225,69.598,3112.25415,48.840,
2033.77380,69.598,3112.34570,48.840,
2033.86523,69.598,3112.43701,48.840,
2033.95679,69.598,3112.52856,48.840,
2034.04834,69.598,3112.62012,49.840,
2034.13989,69.598,3112.71167,48.840,
2034.23132,69.598,3112.80322,48.840,
2034.32288,69.598,3112.89478,48.840,
2034.41443,70.598,3112.98633,49.840,
2034.50586,69.598,3113.07788,49.840,
2034.59741,69.598,3113.16919,49.840,
2034.68896,69.598,3113.26074,49.840,
2034.78052,69.598,3113.35229,49.840,
2034.87195,70.598,3113.44385,48.840,
2034.96350,69.598,3113.53540,49.840,
2035.05505,69.598,3113.62695,49.840,
2035.14661,69.598,3113.71851,49.840,
2035.23804,69.598,3113.81006,48.840,
2035.32959,70.598,3113.90137,48.840,
2035.42114,69.598,3113.99292,49.840,
2035.51270,69.598,3114.08447,49.840,
2035.60413,69.598,3114.17603,49.840,
2035.69568,69.598,3114.26758,49.840,
2035.78723,69.598,3114.35913,49.840,
2035.87878,70.598,3114.45068,49.840,
2035.97021,69.598,3114.54199,49.840,
2036.06177,70.598,3114.63354,49.840,
2036.15332,69.598,3114.72510,49.840,
2036.24487,70.598,3114.81665,49.840,
2036.33630,70.598,3114.90820,48.840,
2036.42786,69.598,3114.99976,49.840,
2036.51941,70.598,3115.09131,49.840,
2036.61084,70.598,3115.18286,49.840,
2036.70239,70.598,3115.27417,49.840,
2036.79395,70.598,3115.36572,49.840,
2036.88550,70.598,3115.45728,49.840,
2036.97693,70.598,3115.54883,49.840,
2037.06848,70.598,3115.64038,49.840,
2037.16003,70.598,3115.73193,49.840,
2037.25159,70.598,3115.82349,49.840,
2037.34302,70.598,3115.91479,49.840,
2037.43457,70.598,3116.00635,49.840,
2037.52612,70.598,3116.09790,49.840,
2037.61768,70.598,3116.18945,49.840,
2037.70911,70.598,3116.28101,49.840,
2037.80066,71.598,3116.37256,49.840,
2037.89221,70.598,3116.46411,49.840,
2037.98376,70.598,3116.55566,49.840,
2038.07520,70.598,3116.64697,49.840,
2038.16675,70.598,3116.73853,49.840,
2038.25830,70.598,3116.83008,49.840,
2038.34973,71.598,3116.92163,49.840,
2038.44128,71.598,3117.01318,49.840,
2038.53284,70.598,3117.10474,49.840,
2038.62439,70.598,3117.19629,49.840,
2038.71582,71.598,3117.28784,50.840,
2038.80737,70.598,3117.37915,49.840,
2038.89893,70.598,3117.47070,49.840,
2038.99048,70.598,3117.56226,50.840,
2039.08191,70.598,3117.65381,49.840,
2039.17346,70.598,3117.74536,50.840,
2039.26501,71.598,3117.83691,50.840,
2039.35657,71.598,3117.92847,50.840,
2039.44800,70.598,3118.01978,50.840,
2039.53955,70.598,3118.11133,50.840,
2039.63110,71.598,3118.20288,49.840,
2039.72266,71.598,3118.29443,50.840,
2039.81409,71.598,3118.38599,50.840,
2039.90564,71.598,3118.47754,50.840,
2039.99719,71.598,3118.56909,50.840,
2040.08875,70.598,3118.66064,50.840,
2040.18018,71.598,3118.75195,50.840,
2040.27173,71.598,3118.84351,49.840,
2040.36328,70.598,3118.93506,50.840,
2040.45471,70.598,3119.02661,50.840,
2040.54626,71.598,3119.11816,50.840,
2040.63782,71.598,3119.20972,49.840,
2040.72937,71.598,3119.30127,50.840,
2040.82080,71.598,3119.39282,50.840,
2040.91235,71.598,3119.48413,50.840,
2041.00391,71.598,3119.57568,49.840,
2041.09546,72.598,3119.66724,50.840,
2041.18689,71.598,3119.75879,50.840,
2041.27844,70.598,3119.85034,50.840,
2041.37000,71.598,3119.94189,50.840,
2041.46155,71.598,3120.03345,50.840,
2041.55298,71.598,3120.12476,50.840,
2041.64453,71.598,3120.21631,50.840,
2041.73608,71.598,3120.30786,50.840,
2041.82764,71.598,3120.39941,50.840,
2041.91907,70.598,3120.49097,50.840,
2042.01062,71.598,3120.58252,50.840,
2042.10217,70.598,3120.67407,50.840,
2042.19360,71.598,3120.76563,50.840,
2042.28516,70.598,3120.85693,50.840,
2042.37671,70.598,3120.94849,50.840,
2042.46826,70.598,3121.04004,50.840,
2042.55969,71.598,3121.13159,50.840,
2042.65125,71.598,3121.22314,50.840,
2042.74280,70.598,3121.31470,50.840,
2042.83435,71.598,3121.40625,51.840,
2042.92578,71.598,3121.49756,51.840,
2043.01733,71.598,3121.58911,50.840,
2043.10889,71.598,3121.68066,50.840,
2043.20044,71.598,3121.77222,50.840,
2043.29187,71.598,3121.86377,51.840,
2043.38342,71.598,3121.95532,50.840,
2043.47498,71.598,3122.04688,51.840,
2043.56653,71.598,3122.13843,50.840,
2043.65796,72.598,3122.22974,51.840,
2043.74951,72.598,3122.32129,50.840,
2043.84106,72.598,3122.41284,51.840,
2043.93250,72.598,3122.50439,50.840,
2044.02405,72.598,3122.59595,51.840,
2044.11560,72.598,3122.68750,50.840,
2044.20715,72.598,3122.77905,51.840,
2044.29858,73.598,3122.87061,51.840,
2044.39014,72.598,3122.96191,51.840,
2044.48169,72.598,3123.05347,51.840,
2044.57324,71.598,3123.14502,51.840,
2044.66467,72.598,3123.23657,51.840,
2044.75623,71.598,3123.32813,51.840,
2044.84778,72.598,3123.41968,51.840,
2044.93933,72.598,3123.51123,51.840,
2045.03076,72.598,3123.60254,51.840,
2045.12231,72.598,3123.69409,51.840,
2045.21387,72.598,3123.78564,51.840,
2045.30542,72.598,3123.87720,51.840,
2045.39685,72.598,3123.96875,51.840,
2045.48840,72.598,3124.06030,51.840,
2045.57996,72.598,3124.15186,51.840,
2045.67151,72.598,3124.24341,51.840,
2045.76294,72.598,3124.33472,52.840,
2045.85449,71.598,3124.42627,51.840,
2045.94604,71.598,3124.51782,51.840,
2046.03748,72.598,3124.60938,51.840,
2046.12903,71.598,3124.70093,52.840,
2046.22058,73.598,3124.79248,51.840,
2046.31213,73.598,3124.88403,51.840,
2046.40356,73.598,3124.97559,51.840,
2046.49512,73.598,3125.06689,52.840,
2046.58667,74.598,3125.15845,52.840,
2046.67822,74.598,3125.25000,52.840,
2046.76965,74.598,3125.34155,52.840,
2046.86121,74.598,3125.43311,52.840,
2046.95276,74.598,3125.52466,52.840,
2047.04431,74.598,3125.61621,52.840,
2047.13574,73.598,3125.70752,52.840,
2047.22729,73.598,3125.79907,53.840,
2047.31885,74.598,3125.89063,53.840,
2047.41040,73.598,3125.98218,52.840,
2047.50183,72.598,3126.07373,53.840,
2047.59338,73.598,3126.16528,52.840,
2047.68494,73.598,3126.25684,52.840,
2047.77637,72.598,3126.34839,52.840,
2047.86792,72.598,3126.43970,52.840,
2047.95947,72.598,3126.53125,52.840,
2048.05103,72.598,3126.62280,52.840,
2048.14258,72.598,3126.71436,52.840,
2048.23413,72.598,3126.80591,52.840,
2048.32544,72.598,3126.89746,51.840,
2048.41699,72.598,3126.98901,52.840,
2048.50854,72.598,3127.08032,52.840,
2048.60010,72.598,3127.17188,52.840,
2048.69165,72.598,3127.26343,52.840,
2048.78320,72.598,3127.35498,52.840,
2048.87476,72.598,3127.44653,52.840,
2048.96631,72.598,3127.53809,52.840,
2049.05762,72.598,3127.62964,52.840,
2049.14917,72.598,3127.72119,52.840,
2049.24072,72.598,3127.81250,52.840,
2049.33228,72.598,3127.90405,52.840,
2049.42383,72.598,3127.99561,52.840,
2049.51538,73.598,3128.08716,52.840,
2049.60693,72.598,3128.17871,52.840,
2049.69824,72.598,3128.27026,52.840,
2049.78979,73.598,3128.36182,53.840,
2049.88135,73.598,3128.45337,53.840,
2049.97290,72.598,3128.54468,53.840,
2050.06445,72.598,3128.63623,53.840,
2050.15601,72.598,3128.72778,54.840,
2050.24756,72.598,3128.81934,53.840,
2050.33911,72.598,3128.91089,54.840,
2050.43042,72.598,3129.00244,53.840,
2050.52197,72.598,3129.09399,53.840,
2050.61353,72.598,3129.18530,53.840,
2050.70508,72.598,3129.27686,53.840,
2050.79663,72.598,3129.36841,53.840,
2050.88818,72.598,3129.45996,54.840,
2050.97974,73.598,3129.55151,53.840,
2051.07129,72.598,3129.64307,53.840,
2051.16260,73.598,3129.73462,53.840,
2051.25415,73.598,3129.82617,53.840,
2051.34570,72.598,3129.91748,53.840,
2051.43726,72.598,3130.00903,53.840,
2051.52881,73.598,3130.10059,53.840,
2051.62036,73.598,3130.19214,53.840,
2051.71191,73.598,3130.28369,53.840,
2051.80322,73.598,3130.37524,53.840,
2051.89478,73.598,3130.46680,53.840,
2051.98633,73.598,3130.55835,53.840,
2052.07788,73.598,3130.64966,53.840,
2052.16943,73.598,3130.74121,53.840,
2052.26099,73.598,3130.83276,53.840,
2052.35254,73.598,3130.92432,53.840,
2052.44409,73.598,3131.01587,53.840,
2052.53540,73.598,3131.10742,53.840,
2052.62695,73.598,3131.19897,53.840,
2052.71851,73.598,3131.29028,53.840,
2052.81006,73.598,3131.38184,54.840,
2052.90161,73.598,3131.47339,53.840,
2052.99316,73.598,3131.56494,53.840,
2053.08472,73.598,3131.65649,54.840,
2053.17627,73.598,3131.74805,53.840,
2053.26758,72.598,3131.83960,53.840,
2053.35913,73.598,3131.93115,53.840,
2053.45068,73.598,3132.02246,53.840,
2053.54224,73.598,3132.11401,53.840,
2053.63379,73.598,3132.20557,53.840,
2053.72534,73.598,3132.29712,54.840,
2053.81689,73.598,3132.38867,54.840,
2053.90820,73.598,3132.48022,54.840,
2053.99976,73.598,3132.57178,53.840,
2054.09131,73.598,3132.66333,54.840,
2054.18286,73.598,3132.75464,53.840,
2054.27441,73.598,3132.84619,54.840,
2054.36597,73.598,3132.93774,53.840,
2054.45752,73.598,3133.02930,54.840,
2054.54907,73.598,3133.12085,54.840,
2054.64038,73.598,3133.21240,54.840,
2054.73193,73.598,3133.30396,53.840,
2054.82349,73.598,3133.39526,53.840,
2054.91504,73.598,3133.48682,54.840,
2055.00659,73.598,3133.57837,54.840,
2055.09814,73.598,3133.66992,54.840,
2055.18970,73.598,3133.76147,54.840,
2055.28101,74.598,3133.85303,54.840,
2055.37256,74.598,3133.94458,53.840,
2055.46411,74.598,3134.03613,53.840,
2055.55566,74.598,3134.12744,54.840,
2055.64722,74.598,3134.21899,54.840,
2055.73877,73.598,3134.31055,53.840,
2055.83032,73.598,3134.40210,54.840,
2055.92188,73.598,3134.49365,54.840,
2056.01318,73.598,3134.58521,54.840,
2056.10474,74.598,3134.67676,54.840,
2056.19629,73.598,3134.76807,54.840,
2056.28784,74.598,3134.85962,54.840,
2056.37939,73.598,3134.95117,54.840,
2056.47095,74.598,3135.04272,54.840,
2056.56250,74.598,3135.13428,54.840,
2056.65405,73.598,3135.22583,55.840,
2056.74536,74.598,3135.31738,55.840,
2056.83691,74.598,3135.40894,54.840,
2056.92847,74.598,3135.50024,54.840,
2057.02002,74.598,3135.59180,55.840,
2057.11157,74.598,3135.68335,55.840,
2057.20313,74.598,3135.77490,54.840,
2057.29468,74.598,3135.86646,55.840,
2057.38599,74.598,3135.95801,55.840,
2057.47754,74.598,3136.04956,55.840,
2057.56909,74.598,3136.14111,55.840,
2057.66064,74.598,3136.23242,55.840,
2057.75220,74.598,3136.32397,55.840,
2057.84375,74.598,3136.41553,55.840,
2057.93530,74.598,3136.50708,55.840,
2058.02686,74.598,3136.59863,55.840,
2058.11816,74.598,3136.69019,55.840,
2058.20972,74.598,3136.78174,55.840,
2058.30127,75.598,3136.87305,55.840,
2058.39282,75.598,3136.96460,55.840,
2058.48438,74.598,3137.05615,55.840,
2058.57593,75.598,3137.14771,55.840,
2058.66748,75.598,3137.23926,55.840,
2058.75903,74.598,3137.33081,55.840,
2058.85034,75.598,3137.42236,55.840,
2058.94189,75.598,3137.51392,55.840,
2059.03345,75.598,3137.60522,55.840,
2059.12500,74.598,3137.69678,55.840,
2059.21655,74.598,3137.78833,55.840,
2059.30811,75.598,3137.87988,55.840,
2059.39966,74.598,3137.97144,55.840,
2059.49097,74.598,3138.06299,55.840,
2059.58252,74.598,3138.15454,55.840,
2059.67407,74.598,3138.24609,55.840,
2059.76563,75.598,3138.33740,55.840,
2059.85718,74.598,3138.42896,55.840,
2059.94873,74.598,3138.52051,55.840,
2060.04028,74.598,3138.61206,56.840,
2060.13184,74.598,3138.70361,56.840,
2060.22314,75.598,3138.79517,56.840,
2060.31470,74.598,3138.88672,55.840,
2060.40625,75.598,3138.97803,56.840,
2060.49780,74.598,3139.06958,56.840,
2060.58936,74.598,3139.16113,56.840,
2060.68091,74.598,3139.25269,56.840,
2060.77246,74.598,3139.34424,56.840,
2060.86377,75.598,3139.43579,56.840,
2060.95532,74.598,3139.52734,56.840,
2061.04688,74.598,3139.61890,57.840,
2061.13843,75.598,3139.71021,56.840,
2061.22998,75.598,3139.80176,56.840,
2061.32153,75.598,3139.89331,56.840,
2061.41309,75.598,3139.98486,56.840,
2061.50464,74.598,3140.07642,56.840,
2061.59595,75.598,3140.16797,56.840,
2061.68750,75.598,3140.25952,56.840,
2061.77905,75.598,3140.35083,56.840,
2061.87061,75.598,3140.44238,57.840,
2061.96216,75.598,3140.53394,56.840,
2062.05371,74.598,3140.62549,56.840,
2062.14526,74.598,3140.71704,56.840,
2062.23682,74.598,3140.80859,56.840,
2062.32813,75.598,3140.90015,56.840,
2062.41968,74.598,3140.99170,56.840,
2062.51123,74.598,3141.08301,57.840,
2062.60278,75.598,3141.17456,56.840,
2062.69434,74.598,3141.26611,56.840,
2062.78589,74.598,3141.35767,56.840,
2062.87744,75.598,3141.44922,57.840,
2062.96875,75.598,3141.54077,56.840,
2063.06030,75.598,3141.63232,56.840,
2063.15186,75.598,3141.72388,56.840,
2063.24341,75.598,3141.81519,56.840,
2063.33496,76.598,3141.90674,56.840,
2063.42651,75.598,3141.99829,57.840,
2063.51807,75.598,3142.08984,57.840,
2063.60962,75.598,3142.18140,56.840,
2063.70093,75.598,3142.27295,56.840,
2063.79248,75.598,3142.36450,57.840,
2063.88403,75.598,3142.45581,56.840,
2063.97559,75.598,3142.54736,57.840,
2064.06714,75.598,3142.63892,57.840,
2064.15869,76.598,3142.73047,57.840,
2064.25024,75.598,3142.82202,56.840,
2064.34180,75.598,3142.91357,57.840,
2064.43311,75.598,3143.00513,57.840,
2064.52466,74.598,3143.09668,57.840,
2064.61621,74.598,3143.18799,57.840,
2064.70776,74.598,3143.27954,57.840,
2064.79932,74.598,3143.37109,57.840,
2064.89087,73.598,3143.46265,57.840,
2064.98242,73.598,3143.55420,57.840,
2065.07373,74.598,3143.64575,57.840,
2065.16528,73.598,3143.73730,57.840,
2065.25684,73.598,3143.82886,57.840,
2065.34839,74.598,3143.92017,57.840,
2065.43994,74.598,3144.01172,57.840,
2065.53149,73.598,3144.10327,57.840,
2065.62305,74.598,3144.19482,57.840,
2065.71460,74.598,3144.28638,57.840,
2065.80591,75.598,3144.37793,56.840,
2065.89746,75.598,3144.46948,57.840,
2065.98901,75.598,3144.56079,57.840,
2066.08057,75.598,3144.65234,56.840,
2066.17212,75.598,3144.74390,57.840,
2066.26367,75.598,3144.83545,58.840,
2066.35522,75.598,3144.92700,57.840,
2066.44678,75.598,3145.01855,57.840,
2066.53809,75.598,3145.11011,58.840,
2066.62964,76.598,3145.20166,58.840,
2066.72119,75.598,3145.29297,57.840,
2066.81274,75.598,3145.38452,58.840,
2066.90430,76.598,3145.47607,57.840,
2066.99585,75.598,3145.56763,58.840,
2067.08740,76.598,3145.65918,58.840,
2067.17871,76.598,3145.75073,58.840,
2067.27026,75.598,3145.84229,58.840,
2067.36182,76.598,3145.93359,57.840,
2067.45337,76.598,3146.02515,58.840,
2067.54492,76.598,3146.11670,57.840,
2067.63647,76.598,3146.20825,57.840,
2067.72803,76.598,3146.29980,58.840,
2067.81958,76.598,3146.39136,58.840,
2067.91089,76.598,3146.48291,57.840,
2068.00244,76.598,3146.57446,58.840,
2068.09399,76.598,3146.66577,58.840,
2068.18555,76.598,3146.75732,58.840,
2068.27710,76.598,3146.84888,58.840,
2068.36865,76.598,3146.94043,58.840,
2068.46021,76.598,3147.03198,58.840,
2068.55151,77.598,3147.12354,58.840,
2068.64307,76.598,3147.21509,58.840,
2068.73462,76.598,3147.30664,59.840,
2068.82617,76.598,3147.39795,57.840,
2068.91772,76.598,3147.48950,58.840,
2069.00928,76.598,3147.58105,58.840,
2069.10083,77.598,3147.67261,58.840,
2069.19238,76.598,3147.76416,59.840,
2069.28369,77.598,3147.85571,58.840,
2069.37524,77.598,3147.94727,59.840,
2069.46680,76.598,3148.03857,59.840,
2069.55835,76.598,3148.13013,59.840,
2069.64990,77.598,3148.22168,59.840,
2069.74146,76.598,3148.31323,59.840,
2069.83301,76.598,3148.40479,59.840,
2069.92456,77.598,3148.49634,59.840,
2070.01587,77.598,3148.58789,59.840,
2070.10742,76.598,3148.67944,58.840,
2070.19897,77.598,3148.77075,59.840,
2070.29053,77.598,3148.86230,59.840,
2070.38208,76.598,3148.95386,59.840,
2070.47363,77.598,3149.04541,59.840,
2070.56519,77.598,3149.13696,60.840,
2070.65649,77.598,3149.22852,60.840,
2070.74805,77.598,3149.32007,59.840,
2070.83960,77.598,3149.41162,59.840,
2070.93115,77.598,3149.50293,59.840,
2071.02271,76.598,3149.59448,59.840,
2071.11426,77.598,3149.68604,59.840,
2071.20581,77.598,3149.77759,60.840,
2071.29736,76.598,3149.86914,59.840,
2071.38867,77.598,3149.96069,59.840,
2071.48022,77.598,3150.05225,59.840,
2071.57178,77.598,3150.14355,59.840,
2071.66333,77.598,3150.23511,59.840,
2071.75488,77.598,3150.32666,60.840,
2071.84644,77.598,3150.41821,59.840,
2071.93799,77.598,3150.50977,59.840,
2072.02954,77.598,3150.60132,60.840,
2072.12085,77.598,3150.69287,60.840,
2072.21240,77.598,3150.78442,60.840,
2072.30396,77.598,3150.87573,60.840,
2072.39551,77.598,3150.96729,60.840,
2072.48706,77.598,3151.05884,60.840,
2072.57861,77.598,3151.15039,60.840,
2072.67017,77.598,3151.24194,60.840,
2072.76147,77.598,3151.33350,60.840,
2072.85303,77.598,3151.42505,60.840,
2072.94458,78.598,3151.51660,60.840,
2073.03613,77.598,3151.60791,60.840,
2073.12769,77.598,3151.69946,59.840,
2073.21924,77.598,3151.79102,60.840,
2073.31079,77.598,3151.88257,60.840,
2073.40234,77.598,3151.97412,60.840,
2073.49365,77.598,3152.06567,60.840,
2073.58521,77.598,3152.15723,61.840,
2073.67676,77.598,3152.24854,60.840,
2073.76831,77.598,3152.34009,60.840,
2073.85986,78.598,3152.43164,60.840,
2073.95142,77.598,3152.52319,60.840,
2074.04297,77.598,3152.61475,60.840,
2074.13428,77.598,3152.70630,60.840,
2074.22583,78.598,3152.79785,60.840,
2074.31738,78.598,3152.88940,61.840,
2074.40894,78.598,3152.98071,60.840,
2074.50049,78.598,3153.07227,60.840,
2074.59204,77.598,3153.16382,61.840,
2074.68359,78.598,3153.25537,60.840,
2074.77515,78.598,3153.34692,61.840,
2074.86646,78.598,3153.43848,61.840,
2074.95801,78.598,3153.53003,60.840,
2075.04956,77.598,3153.62134,61.840,
2075.14111,78.598,3153.71289,61.840,
2075.23267,77.598,3153.80444,61.840,
2075.32422,77.598,3153.89600,61.840,
2075.41577,78.598,3153.98755,61.840,
2075.50732,78.598,3154.07910,61.840,
2075.59863,77.598,3154.17065,61.840,
2075.69019,77.598,3154.26221,61.840,
2075.78174,78.598,3154.35352,61.840,
2075.87329,78.598,3154.44507,61.840,
2075.96484,78.598,3154.53662,61.840,
2076.05640,78.598,3154.62817,61.840,
2076.14795,78.598,3154.71973,61.840,
2076.23926,77.598,3154.81128,61.840,
2076.33081,78.598,3154.90283,61.840,
2076.42236,78.598,3154.99438,61.840,
2076.51392,78.598,3155.08569,61.840,
2076.60547,78.598,3155.17725,61.840,
2076.69702,78.598,3155.26880,61.840,
2076.78857,78.598,3155.36035,61.840,
2076.88013,78.598,3155.45190,61.840,
2076.97144,78.598,3155.54346,61.840,
2077.06299,78.598,3155.63501,61.840,
2077.15454,78.598,3155.72632,61.840,
2077.24609,78.598,3155.81787,61.840,
2077.33765,78.598,3155.90942,61.840,
2077.42920,78.598,3156.00098,61.840,
2077.52075,78.598,3156.09253,61.840,
2077.61230,78.598,3156.18408,62.840,
2077.70361,78.598,3156.27563,62.840,
2077.79517,78.598,3156.36719,61.840,
2077.88672,78.598,3156.45850,62.840,
2077.97827,79.598,3156.55005,62.840,
2078.06982,78.598,3156.64160,62.840,
2078.16138,78.598,3156.73315,62.840,
2078.25293,78.598,3156.82471,62.840,
2078.34424,78.598,3156.91626,62.840,
2078.43579,78.598,3157.00781,62.840,
2078.52734,79.598,3157.09937,62.840,
2078.61890,78.598,3157.19067,63.840,
2078.71045,79.598,3157.28223,62.840,
2078.80200,79.598,3157.37378,62.840,
2078.89355,79.598,3157.46533,62.840,
2078.98511,78.598,3157.55688,62.840,
2079.07642,79.598,3157.64844,62.840,
2079.16797,79.598,3157.73999,62.840,
2079.25952,79.598,3157.83130,62.840,
2079.35107,79.598,3157.92285,62.840,
2079.44263,79.598,3158.01440,63.840,
2079.53418,79.598,3158.10596,62.840,
2079.62573,79.598,3158.19751,63.840,
2079.71704,79.598,3158.28906,62.840,
2079.80859,79.598,3158.38062,63.840,
2079.90015,79.598,3158.47217,62.840,
2079.99170,79.598,3158.56348,63.840,
2080.08325,79.598,3158.65503,63.840,
2080.17480,79.598,3158.74658,63.840,
2080.26636,79.598,3158.83813,63.840,
2080.35791,79.598,3158.92969,63.840,
2080.44922,79.598,3159.02124,62.840,
2080.54077,79.598,3159.11279,63.840,
2080.63232,79.598,3159.20410,62.840,
2080.72388,79.598,3159.29565,63.840,
2080.81543,79.598,3159.38721,63.840,
2080.90698,79.598,3159.47876,63.840,
2080.99854,80.598,3159.57031,63.840,
2081.09009,79.598,3159.66187,62.840,
2081.18140,79.598,3159.75342,63.840,
2081.27295,80.598,3159.84497,63.840,
2081.36450,80.598,3159.93628,63.840,
2081.45605,79.598,3160.02783,63.840,
2081.54761,79.598,3160.11938,63.840,
2081.63916,80.598,3160.21094,63.840,
2081.73071,80.598,3160.30249,63.840,
2081.82202,79.598,3160.39404,63.840,
2081.91357,80.598,3160.48560,63.840,
2082.00513,79.598,3160.57715,63.840,
2082.09668,80.598,3160.66846,63.840,
2082.18823,80.598,3160.76001,63.840,
2082.27979,80.598,3160.85156,63.840,
2082.37134,79.598,3160.94312,64.840,
2082.46289,79.598,3161.03467,63.840,
2082.55420,80.598,3161.12622,64.840,
2082.64575,80.598,3161.21777,64.840,
2082.73730,80.598,3161.30908,63.840,
2082.82886,80.598,3161.40063,64.840,
2082.92041,79.598,3161.49219,64.840,
2083.01196,78.598,3161.58374,63.840,
2083.10352,79.598,3161.67529,64.840,
2083.19507,79.598,3161.76685,63.840,
2083.28638,77.598,3161.85840,63.840,
2083.37793,77.598,3161.94995,64.840,
2083.46948,78.598,3162.04126,63.840,
2083.56104,77.598,3162.13281,64.840,
2083.65259,78.598,3162.22437,64.840,
2083.74414,79.598,3162.31592,64.840,
2083.83569,78.598,3162.40747,64.840,
2083.92700,79.598,3162.49902,64.840,
2084.01855,79.598,3162.59058,64.840,
2084.11011,79.598,3162.68213,64.840,
2084.20166,80.598,3162.77344,64.840,
2084.29321,79.598,3162.86499,64.840,
2084.38477,80.598,3162.95654,64.840,
2084.47632,80.598,3163.04810,64.840,
2084.56787,80.598,3163.13965,64.840,
2084.65918,81.598,3163.23120,64.840,
2084.75073,80.598,3163.32275,64.840,
2084.84229,80.598,3163.41406,64.840,
2084.93384,81.598,3163.50562,64.840,
2085.02539,81.598,3163.59717,64.840,
2085.11694,81.598,3163.68872,64.840,
2085.20850,80.598,3163.78027,64.840,
2085.30005,80.598,3163.87183,65.840,
2085.39136,80.598,3163.96338,65.840,
2085.48291,80.598,3164.05493,65.840,
2085.57446,80.598,3164.14624,65.840,
2085.66602,80.598,3164.23779,65.840,
2085.75757,79.598,3164.32935,65.840,
2085.84912,80.598,3164.42090,65.840,
2085.94067,80.598,3164.51245,65.840,
2086.03198,80.598,3164.60400,65.840,
2086.12354,81.598,3164.69556,66.840,
2086.21509,80.598,3164.78687,65.840,
2086.30664,80.598,3164.87842,65.840,
2086.39819,80.598,3164.96997,65.840,
2086.48975,80.598,3165.06152,65.840,
2086.58130,80.598,3165.15308,64.840,
2086.67285,80.598,3165.24463,65.840,
2086.76416,81.598,3165.33618,65.840,
2086.85571,80.598,3165.42773,65.840,
2086.94727,80.598,3165.51904,65.840,
2087.03882,81.598,3165.61060,65.840,
2087.13037,80.598,3165.70215,65.840,
2087.22192,80.598,3165.79370,64.840,
2087.31348,80.598,3165.88525,65.840,
2087.40479,81.598,3165.97681,65.840,
2087.49634,81.598,3166.06836,65.840,
2087.58789,81.598,3166.15991,65.840,
2087.67944,81.598,3166.25122,65.840,
2087.77100,81.598,3166.34277,65.840,
2087.86255,81.598,3166.43433,65.840,
2087.95410,81.598,3166.52588,66.840,
2088.04565,81.598,3166.61743,66.840,
2088.13696,80.598,3166.70898,65.840,
2088.22852,81.598,3166.80054,66.840,
2088.32007,81.598,3166.89185,66.840,
2088.41162,81.598,3166.98340,66.840,
2088.50317,80.598,3167.07495,66.840,
2088.59473,81.598,3167.16650,66.840,
2088.68628,81.598,3167.25806,66.840,
2088.77783,81.598,3167.34961,65.840,
2088.86914,80.598,3167.44116,66.840,
2088.96069,81.598,3167.53271,66.840,
2089.05225,82.598,3167.62402,66.840,
2089.14380,81.598,3167.71558,66.840,
2089.23535,82.598,3167.80713,65.840,
2089.32690,81.598,3167.89868,66.840,
2089.41846,81.598,3167.99023,65.840,
2089.50977,81.598,3168.08179,66.840,
2089.60132,81.598,3168.17334,66.840,
2089.69287,81.598,3168.26489,66.840,
2089.78442,82.598,3168.35620,66.840,
2089.87598,81.598,3168.44775,66.840,
2089.96753,81.598,3168.53931,66.840,
2090.05908,81.598,3168.63086,66.840,
2090.15063,81.598,3168.72241,66.840,
2090.24194,81.598,3168.81396,66.840,
2090.33350,81.598,3168.90552,66.840,
2090.42505,81.598,3168.99683,66.840,
2090.51660,82.598,3169.08838,66.840,
2090.60815,81.598,3169.17993,67.840,
2090.69971,81.598,3169.27148,67.840,
2090.79126,81.598,3169.36304,66.840,
2090.88281,82.598,3169.45459,66.840,
2090.97412,82.598,3169.54614,66.840,
2091.06567,82.598,3169.63770,66.840,
2091.15723,82.598,3169.72900,67.840,
2091.24878,82.598,3169.82056,67.840,
2091.34033,81.598,3169.91211,67.840,
2091.43188,82.598,3170.00366,67.840,
2091.52344,82.598,3170.09521,66.840,
2091.61475,82.598,3170.18677,67.840,
2091.70630,81.598,3170.27832,67.840,
2091.79785,82.598,3170.36987,67.840,
2091.88940,82.598,3170.46118,67.840,
2091.98096,82.598,3170.55273,67.840,
2092.07251,82.598,3170.64429,67.840,
2092.16406,82.598,3170.73584,67.840,
2092.25562,81.598,3170.82739,67.840,
2092.34692,82.598,3170.91895,67.840,
2092.43848,82.598,3171.01050,67.840,
2092.53003,82.598,3171.10181,67.840,
2092.62158,82.598,3171.19336,67.840,
2092.71313,82.598,3171.28491,67.840,
2092.80469,82.598,3171.37646,67.840,
2092.89624,82.598,3171.46802,67.840,
2092.98755,82.598,3171.55957,67.840,
2093.07910,82.598,3171.65112,67.840,
2093.17065,82.598,3171.74268,67.840,
2093.26221,82.598,3171.83398,67.840,
2093.35376,82.598,3171.92554,67.840,
2093.44531,82.598,3172.01709,67.840,
2093.53687,82.598,3172.10864,67.840,
2093.62842,82.598,3172.20020,67.840,
2093.71973,82.598,3172.29175,67.840,
2093.81128,82.598,3172.38330,68.840,
2093.90283,82.598,3172.47461,67.840,
2093.99438,82.598,3172.56616,67.840,
2094.08594,82.598,3172.65771,68.840,
2094.17749,82.598,3172.74927,68.840,
2094.26904,82.598,3172.84082,67.840,
2094.36060,82.598,3172.93237,67.840,
2094.45190,82.598,3173.02393,68.840,
2094.54346,82.598,3173.11548,67.840,
2094.63501,83.598,3173.20679,68.840,
2094.72656,82.598,3173.29834,68.840,
2094.81812,82.598,3173.38989,68.840,
2094.90967,83.598,3173.48145,68.840,
2095.00122,83.598,3173.57300,68.840,
2095.09253,83.598,3173.66455,68.840,
2095.18408,83.598,3173.75610,68.840,
2095.27563,83.598,3173.84766,68.840,
2095.36719,83.598,3173.93896,69.840,
2095.45874,83.598,3174.03052,68.840,
2095.55029,83.598,3174.12207,68.840,
2095.64185,83.598,3174.21362,69.840,
2095.73340,83.598,3174.30518,68.840,
2095.82471,83.598,3174.39673,69.840,
2095.91626,83.598,3174.48828,68.840,
2096.00781,82.598,3174.57959,69.840,
2096.09937,83.598,3174.67114,68.840,
2096.19092,83.598,3174.76270,69.840,
2096.28247,83.598,3174.85425,68.840,
2096.37402,84.598,3174.94580,68.840,
2096.46558,83.598,3175.03735,68.840,
2096.55688,83.598,3175.12891,68.840,
2096.64844,83.598,3175.22046,68.840,
2096.73999,83.598,3175.31177,68.840,
2096.83154,83.598,3175.40332,69.840,
2096.92310,83.598,3175.49487,69.840,
2097.01465,83.598,3175.58643,69.840,
2097.10620,83.598,3175.67798,69.840,
2097.19751,83.598,3175.76953,69.840,
2097.28906,83.598,3175.86108,69.840,
2097.38062,83.598,3175.95264,69.840,
2097.47217,83.598,3176.04395,69.840,
2097.56372,83.598,3176.13550,69.840,
2097.65527,83.598,3176.22705,69.840,
2097.74683,83.598,3176.31860,69.840,
2097.83838,84.598,3176.41016,69.840,
2097.92969,83.598,3176.50171,69.840,
2098.02124,83.598,3176.59326,69.840,
2098.11279,83.598,3176.68457,69.840,
2098.20435,83.598,3176.77612,69.840,
2098.29590,83.598,3176.86768,69.840,
2098.38745,83.598,3176.95923,69.840,
2098.47900,84.598,3177.05078,69.840,
2098.57031,83.598,3177.14233,69.840,
2098.66187,83.598,3177.23389,69.840,
2098.75342,83.598,3177.32544,69.840,
2098.84497,84.598,3177.41675,69.840,
2098.93652,84.598,3177.50830,69.840,
2099.02808,84.598,3177.59985,69.840,
2099.11963,84.598,3177.69141,70.840,
2099.21118,84.598,3177.78296,69.840,
2099.30249,84.598,3177.87451,69.840,
2099.39404,84.598,3177.96606,69.840,
2099.48560,84.598,3178.05737,69.840,
2099.57715,84.598,3178.14893,69.840,
2099.66870,84.598,3178.24048,69.840,
2099.76025,84.598,3178.33203,69.840,
2099.85181,84.598,3178.42358,69.840,
2099.94336,84.598,3178.51514,70.840,
2100.03467,84.598,3178.60669,70.840,
2100.12622,83.598,3178.69824,70.840,
2100.21777,83.598,3178.78955,69.840,
2100.30933,83.598,3178.88110,69.840,
2100.40088,83.598,3178.97266,69.840,
2100.49243,83.598,3179.06421,70.840,
2100.58398,84.598,3179.15576,70.840,
2100.67529,84.598,3179.24731,69.840,
2100.76685,84.598,3179.33887,69.840,
2100.85840,84.598,3179.43042,69.840,
2100.94995,84.598,3179.52173,69.840,
2101.04150,84.598,3179.61328,69.840,
2101.13306,84.598,3179.70483,70.840,
2101.22461,84.598,3179.79639,70.840,
2101.31616,84.598,3179.88794,70.840,
2101.40747,84.598,3179.97949,71.840,
2101.49902,84.598,3180.07104,70.840,
2101.59058,84.598,3180.16235,71.840,
2101.68213,84.598,3180.25391,70.840,
2101.77368,84.598,3180.34546,71.840,
2101.86523,85.598,3180.43701,70.840,
2101.95679,84.598,3180.52856,70.840,
2102.04834,84.598,3180.62012,71.840,
2102.13965,84.598,3180.71167,71.840,
2102.23120,85.598,3180.80322,70.840,
2102.32275,84.598,3180.89453,70.840,
2102.41431,84.598,3180.98608,70.840,
2102.50586,84.598,3181.07764,70.840,
2102.59741,83.598,3181.16919,70.840,
2102.68896,83.598,3181.26074,70.840,
2102.78027,83.598,3181.35229,70.840,
2102.87183,83.598,3181.44385,71.840,
2102.96338,82.598,3181.53540,71.840,
2103.05493,83.598,3181.62671,71.840,
2103.14648,82.598,3181.71826,70.840,
2103.23804,83.598,3181.80981,71.840,
2103.32959,83.598,3181.90137,71.840,
2103.42114,83.598,3181.99292,71.840,
2103.51245,83.598,3182.08447,71.840,
2103.60400,83.598,3182.17603,71.840,
2103.69556,84.598,3182.26733,71.840,
2103.78711,84.598,3182.35889,71.840,
2103.87866,84.598,3182.45044,71.840,
2103.97021,84.598,3182.54199,70.840,
2104.06177,84.598,3182.63354,70.840,
2104.15332,84.598,3182.72510,70.840,
2104.24463,84.598,3182.81665,70.840,
2104.33618,85.598,3182.90820,71.840,
2104.42773,84.598,3182.99951,70.840,
2104.51929,84.598,3183.09106,71.840,
2104.61084,84.598,3183.18262,71.840,
2104.70239,85.598,3183.27417,71.840,
2104.79395,84.598,3183.36572,71.840,
2104.88525,85.598,3183.45728,71.840,
2104.97681,84.598,3183.54883,71.840,
2105.06836,85.598,3183.64014,71.840,
2105.15991,85.598,3183.73169,71.840,
2105.25146,85.598,3183.82324,71.840,
2105.34302,85.598,3183.91479,71.840,
2105.43457,85.598,3184.00635,72.840,
2105.52612,85.598,3184.09790,72.840,
2105.61743,85.598,3184.18945,71.840,
2105.70898,85.598,3184.28101,72.840,
2105.80054,85.598,3184.37231,73.840,
2105.89209,85.598,3184.46387,72.840,
2105.98364,85.598,3184.55542,71.840,
2106.07520,85.598,3184.64697,72.840,
2106.16675,85.598,3184.73853,72.840,
2106.25806,85.598,3184.83008,72.840,
2106.34961,85.598,3184.92163,72.840,
2106.44116,85.598,3185.01318,72.840,
2106.53271,85.598,3185.10449,72.840,
2106.62427,86.598,3185.19604,72.840,
2106.71582,85.598,3185.28760,72.840,
2106.80737,85.598,3185.37915,72.840,
2106.89893,85.598,3185.47070,72.840,
2106.99023,86.598,3185.56226,73.840,
2107.08179,85.598,3185.65381,73.840,
2107.17334,85.598,3185.74512,72.840,
2107.26489,85.598,3185.83667,73.840,
2107.35645,85.598,3185.92822,73.840,
2107.44800,85.598,3186.01978,72.840,
2107.53955,85.598,3186.11133,72.840,
2107.63110,85.598,3186.20288,73.840,
2107.72241,85.598,3186.29443,73.840,
2107.81396,85.598,3186.38599,73.840,
2107.90552,86.598,3186.47729,73.840,
2107.99707,85.598,3186.56885,72.840,
2108.08862,86.598,3186.66040,73.840,
2108.18018,85.598,3186.75195,73.840,
2108.27173,85.598,3186.84351,73.840,
2108.36304,85.598,3186.93506,72.840,
2108.45459,86.598,3187.02661,73.840,
2108.54614,86.598,3187.11816,73.840,
2108.63770,85.598,3187.20947,72.840,
2108.72925,85.598,3187.30103,73.840,
2108.82080,86.598,3187.39258,73.840,
2108.91235,87.598,3187.48413,73.840,
2109.00391,86.598,3187.57568,73.840,
2109.09521,86.598,3187.66724,73.840,
2109.18677,86.598,3187.75879,73.840,
2109.27832,86.598,3187.85010,73.840,
2109.36987,86.598,3187.94165,74.840,
2109.46143,85.598,3188.03320,73.840,
2109.55298,87.598,3188.12476,73.840,
2109.64453,86.598,3188.21631,73.840,
2109.73608,86.598,3188.30786,73.840,
2109.82739,86.598,3188.39941,73.840,
2109.91895,86.598,3188.49097,73.840,
2110.01050,86.598,3188.58228,73.840,
2110.10205,86.598,3188.67383,73.840,
2110.19360,87.598,3188.76538,74.840,
2110.28516,86.598,3188.85693,74.840,
2110.37671,86.598,3188.94849,74.840,
2110.46802,86.598,3189.04004,74.840,
2110.55957,86.598,3189.13159,73.840,
2110.65112,86.598,3189.22290,73.840,
2110.74268,86.598,3189.31445,74.840,
2110.83423,86.598,3189.40601,73.840,
2110.92578,86.598,3189.49756,73.840,
2111.01733,87.598,3189.58911,73.840,
2111.10889,86.598,3189.68066,74.840,
2111.20020,86.598,3189.77222,73.840,
2111.29175,87.598,3189.86377,74.840,
2111.38330,86.598,3189.95508,74.840,
2111.47485,86.598,3190.04663,74.840,
2111.56641,87.598,3190.13818,74.840,
2111.65796,87.598,3190.22974,75.840,
2111.74951,86.598,3190.32129,74.840,
2111.84082,86.598,3190.41284,75.840,
2111.93237,87.598,3190.50439,74.840,
2112.02393,87.598,3190.59595,74.840,
2112.11548,86.598,3190.68726,74.840,
2112.20703,87.598,3190.77881,74.840,
2112.29858,87.598,3190.87036,74.840,
2112.39014,86.598,3190.96191,75.840,
2112.48169,87.598,3191.05347,74.840,
2112.57300,87.598,3191.14502,74.840,
2112.66455,87.598,3191.23657,74.840,
2112.75610,87.598,3191.32788,74.840,
2112.84766,87.598,3191.41943,74.840,
2112.93921,87.598,3191.51099,74.840,
2113.03076,87.598,3191.60254,74.840,
2113.12231,87.598,3191.69409,75.840,
2113.21387,87.598,3191.78564,75.840,
2113.30518,87.598,3191.87720,74.840,
2113.39673,87.598,3191.96875,75.840,
2113.48828,87.598,3192.06006,74.840,
2113.57983,87.598,3192.15161,74.840,
2113.67139,87.598,3192.24316,75.840,
2113.76294,87.598,3192.33472,74.840,
2113.85449,87.598,3192.42627,75.840,
2113.94580,87.598,3192.51782,74.840,
2114.03735,87.598,3192.60938,74.840,
2114.12891,87.598,3192.70093,74.840,
2114.22046,87.598,3192.79224,74.840,
2114.31201,87.598,3192.88379,75.840,
2114.40356,87.598,3192.97534,75.840,
2114.49512,87.598,3193.06689,75.840,
2114.58667,87.598,3193.15845,76.840,
2114.67798,87.598,3193.25000,75.840,
2114.76953,87.598,3193.34155,75.840,
2114.86108,87.598,3193.43286,75.840,
2114.95264,87.598,3193.52441,75.840,
2115.04419,87.598,3193.61597,75.840,
2115.13574,87.598,3193.70752,75.840,
2115.22729,87.598,3193.79907,75.840,
2115.31885,87.598,3193.89063,75.840,
2115.41016,88.598,3193.98218,75.840,
2115.50171,87.598,3194.07373,75.840,
2115.59326,87.598,3194.16504,75.840,
2115.68481,87.598,3194.25659,75.840,
2115.77637,88.598,3194.34814,76.840,
2115.86792,88.598,3194.43970,76.840,
2115.95947,87.598,3194.53125,75.840,
2116.05078,87.598,3194.62280,76.840,
2116.14233,87.598,3194.71436,76.840,
2116.23389,87.598,3194.80591,76.840,
2116.32544,87.598,3194.89722,76.840,
2116.41699,87.598,3194.98877,76.840,
2116.50854,87.598,3195.08032,75.840,
2116.60010,87.598,3195.17188,76.840,
2116.69165,87.598,3195.26343,76.840,
2116.78296,87.598,3195.35498,76.840,
2116.87451,88.598,3195.44653,76.840,
2116.96606,87.598,3195.53784,75.840,
2117.05762,87.598,3195.62939,76.840,
2117.14917,87.598,3195.72095,76.840,
2117.24072,88.598,3195.81250,76.840,
2117.33228,88.598,3195.90405,76.840,
2117.42358,87.598,3195.99561,76.840,
2117.51514,88.598,3196.08716,77.840,
2117.60669,88.598,3196.17871,76.840,
2117.69824,87.598,3196.27002,77.840,
2117.78979,88.598,3196.36157,76.840,
2117.88135,87.598,3196.45313,76.840,
2117.97290,88.598,3196.54468,76.840,
2118.06445,88.598,3196.63623,76.840,
2118.15576,88.598,3196.72778,77.840,
2118.24731,88.598,3196.81934,77.840,
2118.33887,89.598,3196.91064,76.840,
2118.43042,88.598,3197.00220,76.840,
2118.52197,88.598,3197.09375,76.840,
2118.61353,88.598,3197.18530,77.840,
2118.70508,88.598,3197.27686,77.840,
2118.79663,88.598,3197.36841,76.840,
2118.88794,87.598,3197.45996,77.840,
2118.97949,88.598,3197.55151,77.840,
2119.07104,87.598,3197.64282,76.840,
2119.16260,87.598,3197.73438,77.840,
2119.25415,87.598,3197.82593,77.840,
2119.34570,87.598,3197.91748,76.840,
2119.43726,87.598,3198.00903,77.840,
2119.52856,87.598,3198.10059,77.840,
2119.62012,88.598,3198.19214,77.840,
2119.71167,88.598,3198.28369,77.840,
2119.80322,88.598,3198.37500,76.840,
2119.89478,88.598,3198.46655,76.840,
2119.98633,88.598,3198.55811,76.840,
2120.07788,88.598,3198.64966,76.840,
2120.16943,89.598,3198.74121,76.840,
2120.26074,88.598,3198.83276,76.840,
2120.35229,88.598,3198.92432,76.840,
2120.44385,88.598,3199.01563,78.840,
2120.53540,89.598,3199.10718,77.840,
2120.62695,89.598,3199.19873,77.840,
2120.71851,88.598,3199.29028,77.840,
2120.81006,88.598,3199.38184,78.840,
2120.90161,88.598,3199.47339,77.840,
2120.99292,88.598,3199.56494,77.840,
2121.08447,88.598,3199.65649,78.840,
2121.17603,88.598,3199.74780,77.840,
2121.26758,88.598,3199.83936,77.840,
2121.35913,87.598,3199.93091,78.840,
2121.45068,87.598,3200.02246,78.840,
2121.54224,87.598,3200.11401,78.840,
2121.63354,86.598,3200.20557,77.840,
2121.72510,86.598,3200.29712,78.840,
2121.81665,86.598,3200.38867,78.840,
2121.90820,86.598,3200.47998,79.840,
2121.99976,86.598,3200.57153,79.840,
2122.09131,87.598,3200.66309,80.840,
2122.18286,87.598,3200.75464,79.840,
2122.27441,87.598,3200.84619,80.840,
2122.36572,88.598,3200.93774,80.840,
2122.45728,88.598,3201.02930,81.840,
2122.54883,88.598,3201.12061,80.840,
2122.64038,89.598,3201.21216,80.840,
2122.73193,89.598,3201.30371,80.840,
2122.82349,89.598,3201.39526,80.840,
2122.91504,89.598,3201.48682,80.840,
2123.00635,89.598,3201.57837,80.840,
2123.09790,89.598,3201.66992,80.840,
2123.18945,89.598,3201.76147,80.840,
2123.28101,89.598,3201.85278,80.840,
2123.37256,90.598,3201.94434,80.840,
2123.46411,90.598,3202.03589,80.840,
2123.55566,90.598,3202.12744,79.840,
2123.64722,90.598,3202.21899,79.840,
2123.73853,90.598,3202.31055,79.840,
2123.83008,90.598,3202.40210,79.840,
2123.92163,90.598,3202.49341,79.840,
2124.01318,90.598,3202.58496,79.840,
2124.10474,90.598,3202.67651,79.840,
2124.19629,91.598,3202.76807,79.840,
2124.28784,90.598,3202.85962,79.840,
2124.37939,90.598,3202.95117,79.840,
2124.47070,90.598,3203.04272,79.840,
2124.56226,90.598,3203.13428,79.840,
2124.65381,90.598,3203.22559,79.840,
2124.74536,90.598,3203.31714,79.840,
2124.83691,90.598,3203.40869,80.840,
2124.92847,90.598,3203.50024,79.840,
2125.02002,89.598,3203.59180,80.840,
2125.11133,90.598,3203.68335,79.840,
2125.20288,90.598,3203.77490,79.840,
2125.29443,90.598,3203.86646,79.840,
2125.38599,89.598,3203.95776,80.840,
2125.47754,90.598,3204.04932,79.840,
2125.56909,89.598,3204.14087,79.840,
2125.66064,90.598,3204.23242,80.840,
2125.75220,90.598,3204.32397,80.840,
2125.84351,90.598,3204.41553,79.840,
2125.93506,90.598,3204.50708,79.840,
2126.02661,90.598,3204.59839,79.840,
2126.11816,90.598,3204.68994,80.840,
2126.20972,90.598,3204.78149,79.840,
2126.30127,90.598,3204.87305,80.840,
2126.39282,90.598,3204.96460,79.840,
2126.48438,90.598,3205.05615,79.840,
2126.57568,90.598,3205.14771,80.840,
2126.66724,90.598,3205.23926,80.840,
2126.75879,90.598,3205.33057,80.840,
2126.85034,91.598,3205.42212,80.840,
2126.94189,91.598,3205.51367,80.840,
2127.03345,90.598,3205.60522,80.840,
2127.12500,91.598,3205.69678,80.840,
2127.21631,90.598,3205.78833,80.840,
2127.30786,91.598,3205.87988,80.840,
2127.39941,91.598,3205.97144,80.840,
2127.49097,90.598,3206.06274,81.840,
2127.58252,91.598,3206.15430,81.840,
2127.67407,91.598,3206.24585,80.840,
2127.76563,91.598,3206.33740,80.840,
2127.85718,91.598,3206.42896,81.840,
2127.94849,91.598,3206.52051,81.840,
2128.04004,91.598,3206.61206,80.840,
2128.13159,91.598,3206.70337,81.840,
2128.22314,91.598,3206.79492,80.840,
2128.31470,91.598,3206.88647,81.840,
2128.40625,90.598,3206.97803,80.840,
2128.49780,91.598,3207.06958,81.840,
2128.58936,91.598,3207.16113,81.840,
2128.68066,91.598,3207.25269,81.840,
2128.77222,91.598,3207.34424,81.840,
2128.86377,91.598,3207.43555,81.840,
2128.95532,91.598,3207.52710,81.840,
2129.04688,91.598,3207.61865,81.840,
2129.13843,91.598,3207.71021,81.840,
2129.22998,91.598,3207.80176,82.840,
2129.32129,91.598,3207.89331,82.840,
2129.41284,91.598,3207.98486,82.840,
2129.50439,91.598,3208.07617,82.840,
2129.59595,92.598,3208.16772,82.840,
2129.68750,92.598,3208.25928,82.840,
2129.77905,91.598,3208.35083,81.840,
2129.87061,91.598,3208.44238,81.840,
2129.96216,91.598,3208.53394,81.840,
2130.05347,92.598,3208.62549,81.840,
2130.14502,91.598,3208.71704,81.840,
2130.23657,92.598,3208.80835,81.840,
2130.32813,92.598,3208.89990,81.840,
2130.41968,91.598,3208.99146,81.840,
2130.51123,91.598,3209.08301,81.840,
2130.60278,92.598,3209.17456,81.840,
2130.69409,92.598,3209.26611,82.840,
2130.78564,92.598,3209.35767,81.840,
2130.87720,92.598,3209.44922,82.840,
2130.96875,92.598,3209.54053,82.840,
2131.06030,92.598,3209.63208,82.840,
2131.15186,92.598,3209.72363,82.840,
2131.24341,92.598,3209.81519,82.840,
2131.33496,92.598,3209.90674,82.840,
2131.42627,92.598,3209.99829,83.840,
2131.51782,92.598,3210.08984,82.840,
2131.60938,92.598,3210.18115,82.840,
2131.70093,92.598,3210.27271,82.840,
2131.79248,92.598,3210.36426,82.840,
2131.88403,92.598,3210.45581,82.840,
2131.97559,92.598,3210.54736,82.840,
2132.06714,92.598,3210.63892,82.840,
2132.15845,92.598,3210.73047,83.840,
2132.25000,92.598,3210.82202,82.840,
2132.34155,92.598,3210.91333,83.840,
2132.43311,92.598,3211.00488,82.840,
2132.52466,92.598,3211.09644,83.840,
2132.61621,92.598,3211.18799,83.840,
2132.70776,92.598,3211.27954,83.840,
2132.79907,92.598,3211.37109,82.840,
2132.89063,92.598,3211.46265,82.840,
2132.98218,93.598,3211.55420,83.840,
2133.07373,92.598,3211.64551,82.840,
2133.16528,92.598,3211.73706,83.840,
2133.25684,92.598,3211.82861,83.840,
2133.34839,92.598,3211.92017,82.840,
2133.43994,92.598,3212.01172,83.840,
2133.53125,93.598,3212.10327,83.840,
2133.62280,92.598,3212.19482,84.840,
2133.71436,93.598,3212.28613,83.840,
2133.80591,92.598,3212.37769,83.840,
2133.89746,92.598,3212.46924,83.840,
2133.98901,93.598,3212.56079,83.840,
2134.08057,93.598,3212.65234,83.840,
2134.17212,92.598,3212.74390,83.840,
2134.26343,92.598,3212.83545,83.840,
2134.35498,93.598,3212.92700,84.840,
2134.44653,93.598,3213.01831,83.840,
2134.53809,93.598,3213.10986,83.840,
2134.62964,93.598,3213.20142,83.840,
2134.72119,93.598,3213.29297,83.840,
2134.81274,93.598,3213.38452,83.840,
2134.90405,93.598,3213.47607,84.840,
2134.99561,93.598,3213.56763,83.840,
2135.08716,93.598,3213.65918,84.840,
2135.17871,93.598,3213.75049,83.840,
2135.27026,93.598,3213.84204,84.840,
2135.36182,93.598,3213.93359,84.840,
2135.45337,93.598,3214.02515,84.840,
2135.54492,93.598,3214.11670,84.840,
2135.63623,93.598,3214.20825,84.840,
2135.72778,93.598,3214.29980,84.840,
2135.81934,93.598,3214.39111,84.840,
2135.91089,94.598,3214.48267,84.840,
2136.00244,93.598,3214.57422,84.840,
2136.09399,93.598,3214.66577,84.840,
2136.18555,94.598,3214.75732,84.840,
2136.27686,93.598,3214.84888,84.840,
2136.36841,93.598,3214.94043,84.840,
2136.45996,93.598,3215.03198,84.840,
2136.55151,93.598,3215.12329,84.840,
2136.64307,93.598,3215.21484,85.840,
2136.73462,93.598,3215.30640,85.840,
2136.82617,93.598,3215.39795,85.840,
2136.91772,93.598,3215.48950,84.840,
2137.00903,94.598,3215.58105,84.840,
2137.10059,94.598,3215.67261,85.840,
2137.19214,94.598,3215.76392,85.840,
2137.28369,93.598,3215.85547,85.840,
2137.37524,94.598,3215.94702,85.840,
2137.46680,94.598,3216.03857,84.840,
2137.55835,93.598,3216.13013,84.840,
2137.64990,93.598,3216.22168,85.840,
2137.74121,92.598,3216.31323,84.840,
2137.83276,92.598,3216.40479,85.840,
2137.92432,92.598,3216.49609,85.840,
2138.01587,92.598,3216.58765,85.840,
2138.10742,92.598,3216.67920,85.840,
2138.19897,92.598,3216.77075,85.840,
2138.29053,92.598,3216.86230,85.840,
2138.38184,92.598,3216.95386,85.840,
2138.47339,92.598,3217.04541,85.840,
2138.56494,93.598,3217.13696,85.840,
2138.65649,93.598,3217.22827,85.840,
2138.74805,93.598,3217.31982,85.840,
2138.83960,94.598,3217.41138,85.840,
2138.93115,93.598,3217.50293,84.840,
2139.02271,94.598,3217.59448,85.840,
2139.11401,94.598,3217.68604,85.840,
2139.20557,94.598,3217.77759,85.840,
2139.29712,94.598,3217.86890,85.840,
2139.38867,94.598,3217.96045,85.840,
2139.48022,94.598,3218.05200,86.840,
2139.57178,95.598,3218.14355,85.840,
2139.66333,94.598,3218.23511,85.840,
2139.75488,94.598,3218.32666,86.840,
2139.84619,94.598,3218.41821,85.840,
2139.93774,94.598,3218.50977,85.840,
2140.02930,93.598,3218.60107,85.840,
2140.12085,93.598,3218.69263,85.840,
2140.21240,93.598,3218.78418,85.840,
2140.30396,93.598,3218.87573,85.840,
2140.39551,92.598,3218.96729,85.840,
2140.48682,93.598,3219.05884,85.840,
2140.57837,92.598,3219.15039,85.840,
2140.66992,92.598,3219.24194,85.840,
2140.76147,93.598,3219.33325,85.840,
2140.85303,94.598,3219.42480,86.840,
2140.94458,93.598,3219.51636,85.840,
2141.03613,94.598,3219.60791,86.840,
2141.12769,94.598,3219.69946,86.840,
2141.21899,94.598,3219.79102,86.840,
2141.31055,95.598,3219.88257,86.840,
2141.40210,95.598,3219.97388,85.840,
2141.49365,95.598,3220.06543,86.840,
2141.58521,95.598,3220.15698,86.840,
2141.67676,95.598,3220.24854,86.840,
2141.76831,96.598,3220.34009,86.840,
2141.85962,95.598,3220.43164,86.840,
2141.95117,96.598,3220.52319,86.840,
2142.04272,96.598,3220.61475,86.840,
2142.13428,96.598,3220.70605,86.840,
2142.22583,95.598,3220.79761,87.840,
2142.31738,96.598,3220.88916,86.840,
2142.40894,96.598,3220.98071,87.840,
2142.50049,95.598,3221.07227,87.840,
2142.59180,95.598,3221.16382,87.840,
2142.68335,95.598,3221.25537,87.840,
2142.77490,95.598,3221.34668,87.840,
2142.86646,95.598,3221.43823,87.840,
2142.95801,95.598,3221.52979,87.840,
2143.04956,95.598,3221.62134,87.840,
2143.14111,95.598,3221.71289,87.840,
2143.23267,96.598,3221.80444,87.840,
2143.32397,95.598,3221.89600,87.840,
2143.41553,95.598,3221.98755,87.840,
2143.50708,95.598,3222.07886,87.840,
2143.59863,96.598,3222.17041,87.840,
2143.69019,96.598,3222.26196,87.840,
2143.78174,96.598,3222.35352,87.840,
2143.87329,96.598,3222.44507,87.840,
2143.96460,96.598,3222.53662,87.840,
2144.05615,95.598,3222.62817,88.840,
2144.14771,96.598,3222.71973,87.840,
2144.23926,96.598,3222.81104,87.840,
2144.33081,96.598,3222.90259,87.840,
2144.42236,96.598,3222.99414,88.840,
2144.51392,96.598,3223.08569,87.840,
2144.60547,96.598,3223.17725,87.840,
2144.69678,96.598,3223.26880,87.840,
2144.78833,96.598,3223.36035,87.840,
2144.87988,96.598,3223.45166,87.840,
2144.97144,96.598,3223.54321,87.840,
2145.06299,96.598,3223.63477,88.840,
2145.15454,96.598,3223.72632,88.840,
2145.24609,96.598,3223.81787,88.840,
2145.33765,96.598,3223.90942,88.840,
2145.42896,97.598,3224.00098,87.840,
2145.52051,96.598,3224.09253,88.840,
2145.61206,96.598,3224.18384,88.840,
2145.70361,96.598,3224.27539,89.840,
2145.79517,96.598,3224.36694,88.840,
2145.88672,96.598,3224.45850,88.840,
2145.97827,96.598,3224.55005,88.840,
2146.06958,96.598,3224.64160,88.840,
2146.16113,97.598,3224.73315,88.840,
2146.25269,96.598,3224.82471,89.840,
2146.34424,96.598,3224.91602,88.840,
2146.43579,96.598,3225.00757,88.840,
2146.52734,97.598,3225.09912,88.840,
2146.61890,97.598,3225.19067,88.840,
2146.71045,97.598,3225.28223,88.840,
2146.80176,96.598,3225.37378,89.840,
2146.89331,97.598,3225.46533,89.840,
2146.98486,96.598,3225.55664,88.840,
2147.07642,96.598,3225.64819,89.840,
2147.16797,97.598,3225.73975,89.840,
2147.25952,97.598,3225.83130,89.840,
2147.35107,96.598,3225.92285,89.840,
2147.44263,97.598,3226.01440,89.840,
2147.53394,97.598,3226.10596,89.840,
2147.62549,97.598,3226.19751,89.840,
2147.71704,97.598,3226.28882,89.840,
2147.80859,97.598,3226.38037,89.840,
2147.90015,97.598,3226.47192,89.840,
2147.99170,97.598,3226.56348,89.840,
2148.08325,97.598,3226.65503,89.840,
2148.17456,97.598,3226.74658,89.840,
2148.26611,97.598,3226.83813,90.840,
2148.35767,97.598,3226.92944,89.840,
2148.44922,98.598,3227.02100,89.840,
2148.54077,97.598,3227.11255,89.840,
2148.63232,96.598,3227.20410,90.840,
2148.72388,97.598,3227.29565,90.840,
2148.81543,97.598,3227.38721,89.840,
2148.90674,97.598,3227.47876,90.840,
2148.99829,97.598,3227.57031,89.840,
2149.08984,98.598,3227.66162,89.840,
2149.18140,97.598,3227.75317,89.840,
2149.27295,98.598,3227.84473,89.840,
2149.36450,98.598,3227.93628,90.840,
2149.45605,98.598,3228.02783,89.840,
2149.54736,98.598,3228.11938,89.840,
2149.63892,98.598,3228.21094,90.840,
2149.73047,98.598,3228.30249,90.840,
2149.82202,98.598,3228.39380,90.840,
2149.91357,98.598,3228.48535,90.840,
2150.00513,98.598,3228.57690,89.840,
2150.09668,98.598,3228.66846,90.840,
2150.18823,98.598,3228.76001,90.840,
2150.27954,98.598,3228.85156,90.840,
2150.37109,98.598,3228.94312,90.840,
2150.46265,98.598,3229.03442,90.840,
2150.55420,99.598,3229.12598,90.840,
2150.64575,98.598,3229.21753,90.840,
2150.73730,98.598,3229.30908,90.840,
2150.82886,99.598,3229.40063,90.840,
2150.92041,98.598,3229.49219,90.840,
2151.01172,98.598,3229.58374,91.840,
2151.10327,99.598,3229.67529,91.840,
2151.19482,99.598,3229.76660,92.840,
2151.28638,98.598,3229.85815,91.840,
2151.37793,98.598,3229.94971,91.840,
2151.46948,98.598,3230.04126,91.840,
2151.56104,98.598,3230.13281,91.840,
2151.65234,99.598,3230.22437,91.840,
2151.74390,99.598,3230.31592,91.840,
2151.83545,98.598,3230.40747,91.840,
2151.92700,99.598,3230.49878,91.840,
2152.01855,99.598,3230.59033,91.840,
2152.11011,99.598,3230.68188,91.840,
2152.20166,99.598,3230.77344,91.840,
2152.29321,98.598,3230.86499,91.840,
2152.38452,99.598,3230.95654,92.840,
2152.47607,99.598,3231.04810,91.840,
2152.56763,99.598,3231.13940,91.840,
2152.65918,99.598,3231.23096,91.840,
2152.75073,98.598,3231.32251,91.840,
2152.84229,99.598,3231.41406,91.840,
2152.93384,98.598,3231.50562,91.840,
2153.02539,99.598,3231.59717,91.840,
2153.11670,99.598,3231.68872,91.840,
2153.20825,99.598,3231.78027,92.840,
2153.29980,99.598,3231.87158,92.840,
2153.39136,99.598,3231.96313,91.840,
2153.48291,100.598,3232.05469,91.840,
2153.57446,100.598,3232.14624,92.840,
2153.66602,99.598,3232.23779,92.840,
2153.75732,99.598,3232.32935,92.840,
2153.84888,99.598,3232.42090,92.840,
2153.94043,100.598,3232.51245,92.840,
2154.03198,99.598,3232.60376,91.840,
2154.12354,99.598,3232.69531,92.840,
2154.21509,99.598,3232.78687,92.840,
2154.30664,99.598,3232.87842,92.840,
2154.39819,99.598,3232.96997,92.840,
2154.48950,99.598,3233.06152,92.840,
2154.58105,99.598,3233.15308,92.840,
2154.67261,99.598,3233.24438,92.840,
2154.76416,99.598,3233.33594,93.840,
2154.85571,99.598,3233.42749,92.840,
2154.94727,100.598,3233.51904,92.840,
2155.03882,99.598,3233.61060,92.840,
2155.13013,100.598,3233.70215,92.840,
2155.22168,99.598,3233.79370,92.840,
2155.31323,99.598,3233.88525,92.840,
2155.40479,99.598,3233.97656,92.840,
2155.49634,100.598,3234.06812,93.840,
2155.58789,99.598,3234.15967,93.840,
2155.67944,99.598,3234.25122,92.840,
2155.77100,100.598,3234.34277,92.840,
2155.86230,99.598,3234.43433,92.840,
2155.95386,99.598,3234.52588,92.840,
2156.04541,100.598,3234.61719,93.840,
2156.13696,99.598,3234.70874,92.840,
2156.22852,100.598,3234.80029,93.840,
2156.32007,100.598,3234.89185,93.840,
2156.41162,101.598,3234.98340,92.840,
2156.50317,100.598,3235.07495,92.840,
2156.59448,100.598,3235.16650,93.840,
2156.68604,101.598,3235.25806,93.840,
2156.77759,101.598,3235.34937,93.840,
2156.86914,101.598,3235.44092,93.840,
2156.96069,101.598,3235.53247,93.840,
2157.05225,102.598,3235.62402,94.840,
2157.14380,101.598,3235.71558,93.840,
2157.23511,101.598,3235.80713,93.840,
2157.32666,101.598,3235.89868,93.840,
2157.41821,102.598,3235.99023,93.840,
2157.50977,101.598,3236.08154,93.840,
2157.60132,101.598,3236.17310,93.840,
2157.69287,101.598,3236.26465,93.840,
2157.78442,101.598,3236.35620,94.840,
2157.87598,102.598,3236.44775,94.840,
2157.96729,101.598,3236.53931,93.840,
2158.05884,101.598,3236.63086,93.840,
2158.15039,100.598,3236.72217,94.840,
2158.24194,101.598,3236.81372,94.840,
2158.33350,100.598,3236.90527,94.840,
2158.42505,100.598,3236.99683,94.840,
2158.51660,101.598,3237.08838,94.840,
2158.60815,101.598,3237.17993,94.840,
2158.69946,100.598,3237.27148,94.840,
2158.79102,101.598,3237.36304,94.840,
2158.88257,102.598,3237.45435,94.840,
2158.97412,102.598,3237.54590,93.840,
2159.06567,103.598,3237.63745,94.840,
2159.15723,104.598,3237.72900,94.840,
2159.24878,104.598,3237.82056,93.840,
2159.34009,104.598,3237.91211,93.840,
2159.43164,104.598,3238.00366,94.840,
2159.52319,104.598,3238.09521,93.840,
2159.61475,104.598,3238.18652,93.840,
2159.70630,104.598,3238.27808,94.840,
2159.79785,103.598,3238.36963,94.840,
2159.88940,103.598,3238.46118,94.840,
2159.98096,103.598,3238.55273,95.840,
2160.07227,103.598,3238.64429,94.840,
2160.16382,102.598,3238.73584,94.840,
2160.25537,102.598,3238.82715,94.840,
2160.34692,102.598,3238.91870,94.840,
2160.43848,102.598,3239.01025,94.840,
2160.53003,101.598,3239.10181,94.840,
2160.62158,101.598,3239.19336,95.840,
2160.71289,101.598,3239.28491,94.840,
2160.80444,102.598,3239.37646,95.840,
2160.89600,101.598,3239.46802,95.840,
2160.98755,101.598,3239.55933,95.840,
2161.07910,101.598,3239.65088,95.840,
2161.17065,101.598,3239.74243,95.840,
2161.26221,101.598,3239.83398,95.840,
2161.35376,101.598,3239.92554,95.840,
2161.44507,101.598,3240.01709,96.840,
2161.53662,101.598,3240.10864,95.840,
2161.62817,101.598,3240.19995,95.840,
2161.71973,101.598,3240.29150,95.840,
2161.81128,101.598,3240.38306,95.840,
2161.90283,101.598,3240.47461,95.840,
2161.99438,101.598,3240.56616,95.840,
2162.08594,101.598,3240.65771,95.840,
2162.17725,101.598,3240.74927,95.840,
2162.26880,103.598,3240.84082,95.840,
2162.36035,102.598,3240.93213,95.840,
2162.45190,101.598,3241.02368,95.840,
2162.54346,102.598,3241.11523,95.840,
2162.63501,102.598,3241.20679,95.840,
2162.72656,102.598,3241.29834,95.840,
2162.81787,102.598,3241.38989,95.840,
2162.90942,101.598,3241.48145,96.840,
2163.00098,102.598,3241.57300,96.840,
2163.09253,102.598,3241.66431,96.840,
2163.18408,101.598,3241.75586,95.840,
2163.27563,102.598,3241.84741,96.840,
2163.36719,102.598,3241.93896,95.840,
2163.45874,101.598,3242.03052,96.840,
2163.55005,102.598,3242.12207,96.840,
2163.64160,102.598,3242.21362,96.840,
2163.73315,103.598,3242.30493,96.840,
2163.82471,102.598,3242.39648,97.840,
2163.91626,102.598,3242.48804,96.840,
2164.00781,102.598,3242.57959,96.840,
2164.09937,102.598,3242.67114,96.840,
2164.19092,102.598,3242.76270,97.840,
2164.28223,102.598,3242.85425,97.840,
2164.37378,102.598,3242.94580,97.840,
2164.46533,102.598,3243.03711,96.840,
2164.55688,102.598,3243.12866,97.840,
2164.64844,102.598,3243.22021,97.840,
2164.73999,102.598,3243.31177,97.840,
2164.83154,102.598,3243.40332,97.840,
2164.92285,103.598,3243.49487,97.840,
2165.01440,102.598,3243.58643,97.840,
2165.10596,102.598,3243.67798,96.840,
2165.19751,103.598,3243.76929,97.840,
2165.28906,103.598,3243.86084,97.840,
2165.38062,103.598,3243.95239,97.840,
2165.47217,102.598,3244.04395,97.840,
2165.56372,102.598,3244.13550,97.840,
2165.65503,102.598,3244.22705,97.840,
2165.74658,102.598,3244.31860,97.840,
2165.83813,103.598,3244.40991,98.840,
2165.92969,102.598,3244.50146,98.840,
2166.02124,102.598,3244.59302,97.840,
2166.11279,103.598,3244.68457,98.840,
2166.20435,103.598,3244.77612,98.840,
2166.29590,102.598,3244.86768,98.840,
2166.38721,102.598,3244.95923,98.840,
2166.47876,103.598,3245.05078,98.840,
2166.57031,102.598,3245.14209,98.840,
2166.66187,103.598,3245.23364,97.840,
2166.75342,103.598,3245.32520,98.840,
2166.84497,103.598,3245.41675,98.840,
2166.93652,103.598,3245.50830,98.840,
2167.02783,103.598,3245.59985,98.840,
2167.11938,103.598,3245.69141,98.840,
2167.21094,103.598,3245.78271,98.840,
2167.30249,103.598,3245.87427,98.840,
2167.39404,103.598,3245.96582,98.840,
2167.48560,103.598,3246.05737,98.840,
2167.57715,102.598,3246.14893,98.840,
2167.66870,103.598,3246.24048,98.840,
2167.76001,103.598,3246.33203,98.840,
2167.85156,103.598,3246.42358,98.840,
2167.94312,103.598,3246.51489,98.840,
2168.03467,103.598,3246.60645,98.840,
2168.12622,104.598,3246.69800,98.840,
2168.21777,103.598,3246.78955,98.840,
2168.30933,103.598,3246.88110,98.840,
2168.40063,103.598,3246.97266,98.840,
2168.49219,104.598,3247.06421,98.840,
2168.58374,104.598,3247.15576,98.840,
2168.67529,104.598,3247.24707,98.840,
2168.76685,103.598,3247.33862,99.840,
2168.85840,103.598,3247.43018,99.840,
2168.94995,103.598,3247.52173,99.840,
2169.04150,104.598,3247.61328,99.840,
2169.13281,103.598,3247.70483,99.840,
2169.22437,104.598,3247.79639,99.840,
2169.31592,103.598,3247.88770,99.840,
2169.40747,103.598,3247.97925,99.840,
2169.49902,103.598,3248.07080,99.840,
2169.59058,104.598,3248.16235,99.840,
2169.68213,103.598,3248.25391,99.840,
2169.77368,104.598,3248.34546,99.840,
2169.86499,104.598,3248.43701,99.840,
2169.95654,104.598,3248.52856,99.840,
2170.04810,103.598,3248.61987,99.840,
2170.13965,104.598,3248.71143,99.840,
2170.23120,104.598,3248.80298,100.840,
2170.32275,104.598,3248.89453,99.840,
2170.41431,103.598,3248.98608,99.840,
2170.50562,104.598,3249.07764,99.840,
2170.59717,103.598,3249.16919,99.840,
2170.68872,104.598,3249.26074,100.840,
2170.78027,104.598,3249.35205,99.840,
2170.87183,104.598,3249.44360,100.840,
2170.96338,104.598,3249.53516,100.840,
2171.05493,105.598,3249.62671,100.840,
2171.14648,104.598,3249.71826,99.840,
2171.23779,104.598,3249.80981,100.840,
2171.32935,105.598,3249.90137,100.840,
2171.42090,104.598,3249.99268,99.840,
2171.51245,104.598,3250.08423,99.840,
2171.60400,105.598,3250.17578,100.840,
2171.69556,105.598,3250.26733,101.840,
2171.78711,104.598,3250.35889,100.840,
2171.87866,104.598,3250.45044,100.840,
2171.96997,105.598,3250.54199,100.840,
2172.06152,105.598,3250.63354,100.840,
2172.15308,104.598,3250.72485,100.840,
2172.24463,105.598,3250.81641,100.840,
2172.33618,105.598,3250.90796,100.840,
2172.42773,105.598,3250.99951,100.840,
2172.51929,105.598,3251.09106,100.840,
2172.61060,105.598,3251.18262,100.840,
2172.70215,104.598,3251.27417,100.840,
2172.79370,104.598,3251.36572,100.840,
2172.88525,105.598,3251.45703,101.840,
2172.97681,105.598,3251.54858,100.840,
2173.06836,105.598,3251.64014,101.840,
2173.15991,105.598,3251.73169,101.840,
2173.25146,105.598,3251.82324,101.840,
2173.34277,105.598,3251.91479,101.840,
2173.43433,105.598,3252.00635,101.840,
2173.52588,105.598,3252.09766,101.840,
2173.61743,105.598,3252.18921,101.840,
2173.70898,105.598,3252.28076,101.840,
2173.80054,106.598,3252.37231,101.840,
2173.89209,105.598,3252.46387,101.840,
2173.98340,105.598,3252.55542,100.840,
2174.07495,105.598,3252.64697,100.840,
2174.16650,106.598,3252.73853,100.840,
2174.25806,105.598,3252.82983,100.840,
2174.34961,105.598,3252.92139,100.840,
2174.44116,106.598,3253.01294,100.840,
2174.53271,105.598,3253.10449,100.840,
2174.62427,105.598,3253.19604,101.840,
2174.71558,105.598,3253.28760,101.840,
2174.80713,106.598,3253.37915,101.840,
2174.89868,105.598,3253.47046,101.840,
2174.99023,105.598,3253.56201,101.840,
2175.08179,106.598,3253.65356,101.840,
2175.17334,106.598,3253.74512,102.840,
2175.26489,107.598,3253.83667,101.840,
2175.35645,107.598,3253.92822,102.840,
2175.44775,108.598,3254.01978,101.840,
2175.53931,108.598,3254.11133,102.840,
2175.63086,109.598,3254.20264,102.840,
2175.72241,108.598,3254.29419,102.840,
2175.81396,108.598,3254.38574,102.840,
2175.90552,108.598,3254.47729,102.840,
2175.99707,107.598,3254.56885,102.840,
2176.08838,108.598,3254.66040,102.840,
2176.17993,107.598,3254.75195,102.840,
2176.27148,108.598,3254.84351,103.840,
2176.36304,107.598,3254.93481,102.840,
2176.45459,107.598,3255.02637,103.840,
2176.54614,107.598,3255.11792,103.840,
2176.63770,107.598,3255.20947,104.840,
2176.72925,106.598,3255.30103,104.840,
2176.82056,106.598,3255.39258,104.840,
2176.91211,107.598,3255.48413,104.840,
2177.00366,106.598,3255.57544,104.840,
2177.09521,107.598,3255.66699,104.840,
2177.18677,106.598,3255.75854,104.840,
2177.27832,107.598,3255.85010,105.840,
2177.36987,106.598,3255.94165,104.840,
2177.46143,107.598,3256.03320,104.840,
2177.55273,108.598,3256.12476,105.840,
2177.64429,108.598,3256.21631,103.840,
2177.73584,109.598,3256.30762,104.840,
2177.82739,109.598,3256.39917,103.840,
2177.91895,109.598,3256.49072,103.840,
2178.01050,110.598,3256.58228,103.840,
2178.10205,109.598,3256.67383,104.840,
2178.19336,109.598,3256.76538,103.840,
2178.28491,109.598,3256.85693,103.840,
2178.37646,110.598,3256.94849,103.840,
2178.46802,109.598,3257.03979,103.840,
2178.55957,108.598,3257.13135,103.840,
2178.65112,108.598,3257.22290,103.840,
2178.74268,109.598,3257.31445,103.840,
2178.83423,108.598,3257.40601,103.840,
2178.92554,108.598,3257.49756,104.840,
2179.01709,108.598,3257.58911,104.840,
2179.10864,108.598,3257.68042,103.840,
2179.20020,107.598,3257.77197,104.840,
2179.29175,107.598,3257.86353,104.840,
2179.38330,107.598,3257.95508,104.840,
2179.47485,107.598,3258.04663,104.840,
2179.56616,107.598,3258.13818,105.840,
2179.65771,107.598,3258.22974,105.840,
2179.74927,107.598,3258.32129,104.840,
2179.84082,107.598,3258.41260,104.840,
2179.93237,107.598,3258.50415,104.840,
2180.02393,107.598,3258.59570,104.840,
2180.11548,107.598,3258.68726,104.840,
2180.20703,107.598,3258.77881,104.840,
2180.29834,107.598,3258.87036,104.840,
2180.38989,107.598,3258.96191,104.840,
2180.48145,108.598,3259.05322,105.840,
2180.57300,108.598,3259.14478,105.840,
2180.66455,108.598,3259.23633,104.840,
2180.75610,107.598,3259.32788,105.840,
2180.84766,108.598,3259.41943,105.840,
2180.93921,107.598,3259.51099,105.840,
2181.03052,107.598,3259.60254,105.840,
2181.12207,108.598,3259.69409,105.840,
2181.21362,108.598,3259.78540,105.840,
2181.30518,108.598,3259.87695,105.840,
2181.39673,108.598,3259.96851,105.840,
2181.48828,108.598,3260.06006,105.840,
2181.57983,108.598,3260.15161,105.840,
2181.67114,107.598,3260.24316,105.840,
2181.76270,108.598,3260.33472,105.840,
2181.85425,108.598,3260.42627,105.840,
2181.94580,107.598,3260.51758,106.840,
2182.03735,108.598,3260.60913,105.840,
2182.12891,108.598,3260.70068,105.840,
2182.22046,107.598,3260.79224,105.840,
2182.31201,108.598,3260.88379,105.840,
2182.40332,108.598,3260.97534,106.840,
2182.49487,108.598,3261.06689,105.840,
2182.58643,108.598,3261.15820,105.840,
2182.67798,108.598,3261.24976,106.840,
2182.76953,108.598,3261.34131,106.840,
2182.86108,108.598,3261.43286,105.840,
2182.95264,108.598,3261.52441,105.840,
2183.04419,108.598,3261.61597,106.840,
2183.13550,108.598,3261.70752,105.840,
2183.22705,108.598,3261.79907,105.840,
2183.31860,108.598,3261.89038,106.840,
2183.41016,108.598,3261.98193,107.840,
2183.50171,108.598,3262.07349,106.840,
2183.59326,109.598,3262.16504,106.840,
2183.68481,108.598,3262.25659,106.840,
2183.77612,108.598,3262.34814,106.840,
2183.86768,108.598,3262.43970,107.840,
2183.95923,109.598,3262.53125,106.840,
2184.05078,108.598,3262.62256,106.840,
2184.14233,109.598,3262.71411,107.840,
2184.23389,110.598,3262.80566,106.840,
2184.32544,109.598,3262.89722,106.840,
2184.41699,109.598,3262.98877,106.840,
2184.50830,109.598,3263.08032,106.840,
2184.59985,109.598,3263.17188,106.840,
2184.69141,109.598,3263.26318,106.840,
2184.78296,110.598,3263.35474,106.840,
2184.87451,109.598,3263.44629,107.840,
2184.96606,109.598,3263.53784,107.840,
2185.05762,109.598,3263.62939,107.840,
2185.14917,109.598,3263.72095,107.840,
2185.24048,109.598,3263.81250,107.840,
2185.33203,109.598,3263.90405,107.840,
2185.42358,109.598,3263.99536,107.840,
2185.51514,109.598,3264.08691,107.840,
2185.60669,109.598,3264.17847,107.840,
2185.69824,110.598,3264.27002,107.840,
2185.78979,110.598,3264.36157,108.840,
2185.88110,110.598,3264.45313,107.840,
2185.97266,110.598,3264.54468,107.840,
2186.06421,110.598,3264.63599,107.840,
2186.15576,110.598,3264.72754,107.840,
2186.24731,110.598,3264.81909,107.840,
2186.33887,110.598,3264.91064,108.840,
2186.43042,109.598,3265.00220,107.840,
2186.52197,109.598,3265.09375,107.840,
2186.61328,110.598,3265.18530,108.840,
2186.70483,110.598,3265.27686,108.840,
2186.79639,110.598,3265.36816,107.840,
2186.88794,110.598,3265.45972,108.840,
2186.97949,110.598,3265.55127,107.840,
2187.07104,110.598,3265.64282,108.840,
2187.16260,111.598,3265.73438,108.840,
2187.25391,111.598,3265.82593,108.840,
2187.34546,110.598,3265.91748,108.840,
2187.43701,110.598,3266.00903,108.840,
2187.52856,110.598,3266.10034,108.840,
2187.62012,111.598,3266.19189,108.840,
2187.71167,111.598,3266.28345,108.840,
2187.80322,111.598,3266.37500,109.840,
2187.89478,111.598,3266.46655,109.840,
2187.98608,111.598,3266.55811,108.840,
2188.07764,111.598,3266.64966,108.840,
2188.16919,110.598,3266.74097,109.840,
2188.26074,111.598,3266.83252,109.840,
2188.35229,110.598,3266.92407,109.840,
2188.44385,110.598,3267.01563,109.840,
2188.53540,111.598,3267.10718,109.840,
2188.62695,111.598,3267.19873,109.840,
2188.71826,110.598,3267.29028,109.840,
2188.80981,111.598,3267.38184,109.840,
2188.90137,111.598,3267.47314,109.840,
2188.99292,111.598,3267.56470,109.840,
2189.08447,111.598,3267.65625,109.840,
2189.17603,111.598,3267.74780,109.840,
2189.26758,111.598,3267.83936,109.840,
2189.35889,111.598,3267.93091,110.840,
2189.45044,111.598,3268.02246,110.840,
2189.54199,111.598,3268.11401,110.840,
2189.63354,111.598,3268.20532,110.840,
2189.72510,111.598,3268.29688,110.840,
2189.81665,111.598,3268.38843,109.840,
2189.90820,111.598,3268.47998,109.840,
2189.99976,111.598,3268.57153,110.840,
2190.09106,112.598,3268.66309,110.840,
2190.18262,111.598,3268.75464,109.840,
2190.27417,111.598,3268.84595,110.840,
2190.36572,111.598,3268.93750,110.840,
2190.45728,111.598,3269.02905,110.840,
2190.54883,112.598,3269.12061,109.840,
2190.64038,112.598,3269.21216,110.840,
2190.73193,111.598,3269.30371,110.840,
2190.82324,112.598,3269.39526,110.840,
2190.91479,111.598,3269.48682,110.840,
2191.00635,112.598,3269.57813,110.840,
2191.09790,111.598,3269.66968,110.840,
2191.18945,112.598,3269.76123,110.840,
2191.28101,112.598,3269.85278,111.840,
2191.37256,111.598,3269.94434,111.840,
2191.46387,112.598,3270.03589,110.840,
2191.55542,112.598,3270.12744,110.840,
2191.64697,112.598,3270.21875,110.840,
2191.73853,112.598,3270.31030,111.840,
2191.83008,112.598,3270.40186,111.840,
2191.92163,112.598,3270.49341,111.840,
2192.01318,112.598,3270.58496,111.840,
2192.10474,112.598,3270.67651,111.840,
2192.19604,112.598,3270.76807,112.840,
2192.28760,112.598,3270.85962,112.840,
2192.37915,112.598,3270.95093,111.840,
2192.47070,112.598,3271.04248,112.840,
2192.56226,112.598,3271.13403,112.840,
2192.65381,112.598,3271.22559,112.840,
2192.74536,112.598,3271.31714,112.840,
2192.83667,112.598,3271.40869,112.840,
2192.92822,112.598,3271.50024,111.840,
2193.01978,113.598,3271.59180,112.840,
2193.11133,113.598,3271.68311,112.840,
2193.20288,113.598,3271.77466,112.840,
2193.29443,113.598,3271.86621,112.840,
2193.38599,113.598,3271.95776,112.840,
2193.47754,113.598,3272.04932,111.840,
2193.56885,114.598,3272.14087,111.840,
2193.66040,114.598,3272.23242,112.840,
2193.75195,114.598,3272.32373,112.840,
2193.84351,114.598,3272.41528,112.840,
2193.93506,114.598,3272.50684,112.840,
2194.02661,114.598,3272.59839,112.840,
2194.11816,114.598,3272.68994,112.840,
2194.20972,114.598,3272.78149,112.840,
2194.30103,114.598,3272.87305,112.840,
2194.39258,114.598,3272.96460,112.840,
2194.48413,114.598,3273.05591,112.840,
2194.57568,113.598,3273.14746,112.840,
2194.66724,114.598,3273.23901,113.840,
2194.75879,114.598,3273.33057,112.840,
2194.85034,113.598,3273.42212,112.840,
2194.94165,113.598,3273.51367,113.840,
2195.03320,113.598,3273.60522,112.840,
2195.12476,114.598,3273.69678,113.840,
2195.21631,113.598,3273.78809,113.840,
2195.30786,113.598,3273.87964,113.840,
2195.39941,114.598,3273.97119,112.840,
2195.49097,114.598,3274.06274,113.840,
2195.58252,114.598,3274.15430,113.840,
2195.67383,115.598,3274.24585,112.840,
2195.76538,115.598,3274.33740,112.840,
2195.85693,115.598,3274.42871,113.840,
2195.94849,116.598,3274.52026,113.840,
2196.04004,114.598,3274.61182,112.840,
2196.13159,114.598,3274.70337,113.840,
2196.22314,114.598,3274.79492,113.840,
2196.31470,113.598,3274.88647,113.840,
2196.40601,114.598,3274.97803,113.840,
2196.49756,113.598,3275.06958,113.840,
2196.58911,114.598,3275.16089,113.840,
2196.68066,113.598,3275.25244,113.840,
2196.77222,113.598,3275.34399,114.840,
2196.86377,113.598,3275.43555,113.840,
2196.95532,113.598,3275.52710,113.840,
2197.04663,113.598,3275.61865,113.840,
2197.13818,113.598,3275.71021,114.840,
2197.22974,113.598,3275.80176,113.840,
2197.32129,113.598,3275.89307,114.840,
2197.41284,113.598,3275.98462,114.840,
2197.50439,114.598,3276.07617,113.840,
2197.59595,113.598,3276.16772,114.840,
2197.68750,113.598,3276.25928,114.840,
2197.77881,114.598,3276.35083,113.840,
2197.87036,113.598,3276.44238,114.840,
2197.96191,114.598,3276.53369,114.840,
2198.05347,114.598,3276.62524,115.840,
2198.14502,114.598,3276.71680,114.840,
2198.23657,114.598,3276.80835,114.840,
2198.32813,114.598,3276.89990,114.840,
2198.41943,114.598,3276.99146,114.840,
2198.51099,114.598,3277.08301,114.840,
2198.60254,114.598,3277.17456,114.840,
2198.69409,114.598,3277.26587,114.840,
2198.78564,113.598,3277.35742,114.840,
2198.87720,115.598,3277.44897,115.840,
2198.96875,115.598,3277.54053,115.840,
2199.06030,114.598,3277.63208,114.840,
2199.15161,114.598,3277.72363,114.840,
2199.24316,115.598,3277.81519,115.840,
2199.33472,114.598,3277.90649,114.840,
2199.42627,115.598,3277.99805,115.840,
2199.51782,114.598,3278.08960,116.840,
2199.60938,115.598,3278.18115,115.840,
2199.70093,115.598,3278.27271,115.840,
2199.79248,115.598,3278.36426,115.840,
2199.88379,114.598,3278.45581,115.840,
2199.97534,115.598,3278.54736,115.840,
2200.06689,115.598,3278.63867,115.840,
2200.15845,115.598,3278.73022,115.840,
2200.25000,115.598,3278.82178,115.840,
2200.34155,115.598,3278.91333,115.840,
2200.43311,115.598,3279.00488,116.840,
2200.52441,116.598,3279.09644,115.840,
2200.61597,115.598,3279.18799,115.840,
2200.70752,115.598,3279.27954,115.840,
2200.79907,115.598,3279.37085,116.840,
2200.89063,115.598,3279.46240,115.840,
2200.98218,115.598,3279.55396,116.840,
2201.07373,116.598,3279.64551,115.840,
2201.16528,115.598,3279.73706,115.840,
2201.25659,115.598,3279.82861,115.840,
2201.34814,115.598,3279.92017,116.840,
2201.43970,115.598,3280.01147,116.840,
2201.53125,115.598,3280.10303,115.840,
2201.62280,116.598,3280.19458,116.840,
2201.71436,115.598,3280.28613,117.840,
2201.80591,116.598,3280.37769,116.840,
2201.89746,116.598,3280.46924,116.840,
2201.98877,116.598,3280.56079,116.840,
2202.08032,116.598,3280.65234,116.840,
2202.17188,116.598,3280.74365,116.840,
2202.26343,116.598,3280.83521,116.840,
2202.35498,116.598,3280.92676,116.840,
2202.44653,116.598,3281.01831,117.840,
2202.53809,116.598,3281.10986,116.840,
2202.62939,115.598,3281.20142,116.840,
2202.72095,116.598,3281.29297,117.840,
2202.81250,116.598,3281.38452,116.840,
2202.90405,117.598,3281.47583,117.840,
2202.99561,116.598,3281.56738,116.840,
2203.08716,116.598,3281.65894,116.840,
2203.17871,116.598,3281.75049,116.840,
2203.27026,117.598,3281.84204,116.840,
2203.36157,116.598,3281.93359,116.840,
2203.45313,116.598,3282.02515,117.840,
2203.54468,117.598,3282.11646,116.840,
2203.63623,116.598,3282.20801,117.840,
2203.72778,116.598,3282.29956,117.840,
2203.81934,117.598,3282.39111,117.840,
2203.91089,116.598,3282.48267,118.840,
2204.00244,117.598,3282.57422,117.840,
2204.09375,116.598,3282.66577,117.840,
2204.18530,116.598,3282.75732,117.840,
2204.27686,116.598,3282.84863,117.840,
2204.36841,116.598,3282.94019,117.840,
2204.45996,116.598,3283.03174,117.840,
2204.55151,117.598,3283.12329,118.840,
2204.64307,117.598,3283.21484,117.840,
2204.73438,117.598,3283.30640,118.840,
2204.82593,117.598,3283.39795,118.840,
2204.91748,117.598,3283.48926,117.840,
2205.00903,117.598,3283.58081,118.840,
2205.10059,117.598,3283.67236,117.840,
2205.19214,116.598,3283.76392,117.840,
2205.28369,117.598,3283.85547,118.840,
2205.37524,117.598,3283.94702,118.840,
2205.46655,117.598,3284.03857,117.840,
2205.55811,117.598,3284.13013,117.840,
2205.64966,117.598,3284.22144,118.840,
2205.74121,117.598,3284.31299,118.840,
2205.83276,118.598,3284.40454,118.840,
2205.92432,118.598,3284.49609,119.840,
2206.01587,117.598,3284.58765,118.840,
2206.10718,117.598,3284.67920,119.840,
2206.19873,118.598,3284.77075,118.840,
2206.29028,117.598,3284.86230,118.840,
2206.38184,117.598,3284.95361,118.840,
2206.47339,117.598,3285.04517,118.840,
2206.56494,117.598,3285.13672,119.840,
2206.65649,118.598,3285.22827,119.840,
2206.74805,118.598,3285.31982,119.840,
2206.83936,118.598,3285.41138,120.840,
2206.93091,118.598,3285.50293,119.840,
2207.02246,118.598,3285.59424,119.840,
2207.11401,118.598,3285.68579,119.840,
2207.20557,118.598,3285.77734,119.840,
2207.29712,118.598,3285.86890,119.840,
2207.38867,118.598,3285.96045,119.840,
2207.48022,118.598,3286.05200,120.840,
2207.57153,118.598,3286.14355,120.840,
2207.66309,119.598,3286.23511,119.840,
2207.75464,118.598,3286.32642,119.840,
2207.84619,118.598,3286.41797,119.840,
2207.93774,118.598,3286.50952,119.840,
2208.02930,118.598,3286.60107,119.840,
2208.12085,118.598,3286.69263,119.840,
2208.21216,118.598,3286.78418,119.840,
2208.30371,118.598,3286.87573,120.840,
2208.39526,118.598,3286.96729,120.840,
2208.48682,118.598,3287.05859,120.840,
2208.57837,118.598,3287.15015,119.840,
2208.66992,118.598,3287.24170,120.840,
2208.76147,119.598,3287.33325,120.840,
2208.85303,118.598,3287.42480,120.840,
2208.94434,119.598,3287.51636,120.840,
2209.03589,119.598,3287.60791,120.840,
2209.12744,119.598,3287.69922,120.840,
2209.21899,119.598,3287.79077,120.840,
2209.31055,118.598,3287.88232,120.840,
2209.40210,119.598,3287.97388,120.840,
2209.49365,119.598,3288.06543,120.840,
2209.58521,119.598,3288.15698,121.840,
2209.67651,119.598,3288.24854,120.840,
2209.76807,119.598,3288.34009,121.840,
2209.85962,119.598,3288.43140,120.840,
2209.95117,119.598,3288.52295,120.840,
2210.04272,119.598,3288.61450,120.840,
2210.13428,119.598,3288.70605,120.840,
2210.22583,119.598,3288.79761,121.840,
2210.31714,119.598,3288.88916,121.840,
2210.40869,118.598,3288.98071,121.840,
2210.50024,119.598,3289.07202,121.840,
2210.59180,120.598,3289.16357,121.840,
2210.68335,119.598,3289.25513,120.840,
2210.77490,119.598,3289.34668,121.840,
2210.86646,118.598,3289.43823,122.840,
2210.95801,117.598,3289.52979,121.840,
2211.04932,117.598,3289.62134,121.840,
2211.14087,117.598,3289.71289,121.840,
2211.23242,117.598,3289.80420,122.840,
2211.32397,117.598,3289.89575,121.840,
2211.41553,117.598,3289.98730,121.840,
2211.50708,117.598,3290.07886,122.840,
2211.59863,117.598,3290.17041,121.840,
2211.68994,118.598,3290.26196,121.840,
2211.78149,118.598,3290.35352,122.840,
2211.87305,118.598,3290.44507,121.840,
2211.96460,118.598,3290.53638,121.840,
2212.05615,119.598,3290.62793,121.840,
2212.14771,119.598,3290.71948,121.840,
2212.23926,119.598,3290.81104,121.840,
2212.33081,119.598,3290.90259,121.840,
2212.42212,119.598,3290.99414,121.840,
2212.51367,119.598,3291.08569,122.840,
2212.60522,120.598,3291.17700,121.840,
2212.69678,120.598,3291.26855,123.840,
2212.78833,120.598,3291.36011,122.840,
2212.87988,119.598,3291.45166,122.840,
2212.97144,119.598,3291.54321,122.840,
2213.06299,120.598,3291.63477,122.840,
2213.15430,120.598,3291.72632,122.840,
2213.24585,120.598,3291.81787,122.840,
2213.33740,121.598,3291.90918,122.840,
2213.42896,121.598,3292.00073,121.840,
2213.52051,122.598,3292.09229,121.840,
2213.61206,123.598,3292.18384,122.840,
2213.70361,123.598,3292.27539,122.840,
2213.79492,123.598,3292.36694,122.840,
2213.88647,123.598,3292.45850,123.840,
2213.97803,124.598,3292.55005,122.840,
2214.06958,124.598,3292.64136,123.840,
2214.16113,124.598,3292.73291,123.840,
2214.25269,123.598,3292.82446,123.840,
2214.34424,123.598,3292.91602,123.840,
2214.43579,123.598,3293.00757,123.840,
2214.52710,123.598,3293.09912,123.840,
2214.61865,122.598,3293.19067,123.840,
2214.71021,122.598,3293.28198,123.840,
2214.80176,122.598,3293.37354,123.840,
2214.89331,121.598,3293.46509,123.840,
2214.98486,122.598,3293.55664,123.840,
2215.07642,122.598,3293.64819,123.840,
2215.16797,122.598,3293.73975,123.840,
2215.25928,121.598,3293.83130,124.840,
2215.35083,121.598,3293.92285,123.840,
2215.44238,121.598,3294.01416,123.840,
2215.53394,121.598,3294.10571,123.840,
2215.62549,121.598,3294.19727,124.840,
2215.71704,121.598,3294.28882,124.840,
2215.80859,121.598,3294.38037,124.840,
2215.89990,121.598,3294.47192,123.840,
2215.99146,121.598,3294.56348,123.840,
2216.08301,121.598,3294.65503,124.840,
2216.17456,121.598,3294.74634,123.840,
2216.26611,121.598,3294.83789,124.840,
2216.35767,121.598,3294.92944,124.840,
2216.44922,122.598,3295.02100,123.840,
2216.54077,121.598,3295.11255,123.840,
2216.63208,121.598,3295.20410,124.840,
2216.72363,122.598,3295.29565,124.840,
2216.81519,121.598,3295.38696,123.840,
2216.90674,121.598,3295.47852,123.840,
2216.99829,122.598,3295.57007,124.840,
2217.08984,122.598,3295.66162,124.840,
2217.18140,122.598,3295.75317,124.840,
2217.27271,122.598,3295.84473,124.840,
2217.36426,122.598,3295.93628,123.840,
2217.45581,122.598,3296.02783,124.840,
2217.54736,122.598,3296.11914,123.840,
2217.63892,122.598,3296.21069,124.840,
2217.73047,122.598,3296.30225,124.840,
2217.82202,122.598,3296.39380,124.840,
2217.91357,123.598,3296.48535,124.840,
2218.00488,122.598,3296.57690,124.840,
2218.09644,122.598,3296.66846,124.840,
2218.18799,122.598,3296.75977,124.840,
2218.27954,122.598,3296.85132,124.840,
2218.37109,122.598,3296.94287,124.840,
2218.46265,123.598,3297.03442,124.840,
2218.55420,122.598,3297.12598,126.840,
2218.64575,122.598,3297.21753,125.840,
2218.73706,122.598,3297.30908,125.840,
2218.82861,122.598,3297.40063,125.840,
2218.92017,122.598,3297.49194,125.840,
2219.01172,122.598,3297.58350,125.840,
2219.10327,122.598,3297.67505,125.840,
2219.19482,122.598,3297.76660,125.840,
2219.28638,122.598,3297.85815,125.840,
2219.37769,122.598,3297.94971,125.840,
2219.46924,122.598,3298.04126,125.840,
2219.56079,122.598,3298.13281,125.840,
2219.65234,122.598,3298.22412,125.840,
2219.74390,123.598,3298.31567,125.840,
2219.83545,122.598,3298.40723,125.840,
2219.92700,123.598,3298.49878,125.840,
2220.01855,123.598,3298.59033,126.840,
2220.10986,123.598,3298.68188,126.840,
2220.20142,123.598,3298.77344,126.840,
2220.29297,123.598,3298.86475,126.840,
2220.38452,123.598,3298.95630,126.840,
2220.47607,123.598,3299.04785,125.840,
2220.56763,123.598,3299.13940,126.840,
2220.65918,123.598,3299.23096,126.840,
2220.75073,123.598,3299.32251,126.840,
2220.84204,123.598,3299.41406,126.840,
2220.93359,123.598,3299.50562,126.840,
2221.02515,123.598,3299.59692,126.840,
2221.11670,123.598,3299.68848,126.840,
2221.20825,124.598,3299.78003,126.840,
2221.29980,123.598,3299.87158,126.840,
2221.39136,123.598,3299.96313,126.840,
2221.48267,123.598,3300.05469,127.840,
2221.57422,123.598,3300.14624,126.840,
2221.66577,123.598,3300.23779,126.840,
2221.75732,123.598,3300.32910,126.840,
2221.84888,123.598,3300.42065,126.840,
2221.94043,123.598,3300.51221,127.840,
2222.03198,123.598,3300.60376,126.840,
2222.12354,123.598,3300.69531,127.840,
2222.21484,123.598,3300.78687,126.840,
2222.30640,124.598,3300.87842,126.840,
2222.39795,123.598,3300.96973,126.840,
2222.48950,124.598,3301.06128,126.840,
2222.58105,123.598,3301.15283,126.840,
2222.67261,124.598,3301.24438,126.840,
2222.76416,124.598,3301.33594,126.840,
2222.85547,124.598,3301.42749,127.840,
2222.94702,124.598,3301.51904,127.840,
2223.03857,124.598,3301.61060,127.840,
2223.13013,124.598,3301.70190,127.840,
2223.22168,123.598,3301.79346,127.840,
2223.31323,124.598,3301.88501,127.840,
2223.40479,124.598,3301.97656,127.840,
2223.49634,124.598,3302.06812,127.840,
2223.58765,124.598,3302.15967,127.840,
2223.67920,124.598,3302.25122,127.840,
2223.77075,125.598,3302.34253,127.840,
2223.86230,124.598,3302.43408,127.840,
2223.95386,124.598,3302.52563,127.840,
2224.04541,124.598,3302.61719,128.840,
2224.13696,125.598,3302.70874,127.840,
2224.22852,124.598,3302.80029,127.840,
2224.31982,125.598,3302.89185,128.840,
2224.41138,125.598,3302.98340,128.840,
2224.50293,125.598,3303.07471,127.840,
2224.59448,125.598,3303.16626,128.840,
2224.68604,125.598,3303.25781,128.840,
2224.77759,124.598,3303.34937,127.840,
2224.86914,125.598,3303.44092,128.840,
2224.96045,125.598,3303.53247,128.840,
2225.05200,124.598,3303.62402,128.840,
2225.14355,125.598,3303.71558,127.840,
2225.23511,126.598,3303.80688,128.840,
2225.32666,125.598,3303.89844,127.840,
2225.41821,125.598,3303.98999,128.840,
2225.50977,125.598,3304.08154,127.840,
2225.60132,125.598,3304.17310,128.840,
2225.69263,125.598,3304.26465,128.840,
2225.78418,125.598,3304.35620,128.840,
2225.87573,125.598,3304.44751,129.840,
2225.96729,125.598,3304.53906,128.840,
2226.05884,125.598,3304.63062,128.840,
2226.15039,125.598,3304.72217,128.840,
2226.24194,125.598,3304.81372,128.840,
2226.33350,125.598,3304.90527,129.840,
2226.42480,125.598,3304.99683,129.840,
2226.51636,126.598,3305.08838,129.840,
2226.60791,125.598,3305.17969,129.840,
2226.69946,126.598,3305.27124,129.840,
2226.79102,126.598,3305.36279,129.840,
2226.88257,126.598,3305.45435,129.840,
2226.97412,126.598,3305.54590,128.840,
2227.06543,126.598,3305.63745,129.840,
2227.15698,126.598,3305.72900,129.840,
2227.24854,126.598,3305.82056,129.840,
2227.34009,126.598,3305.91187,129.840,
2227.43164,126.598,3306.00342,129.840,
2227.52319,126.598,3306.09497,129.840,
2227.61475,125.598,3306.18652,129.840,
2227.70630,126.598,3306.27808,129.840,
2227.79761,126.598,3306.36963,129.840,
2227.88916,126.598,3306.46118,129.840,
2227.98071,126.598,3306.55249,130.840,
2228.07227,126.598,3306.64404,129.840,
2228.16382,127.598,3306.73560,129.840,
2228.25537,126.598,3306.82715,130.840,
2228.34692,127.598,3306.91870,129.840,
2228.43848,127.598,3307.01025,129.840,
2228.52979,127.598,3307.10181,129.840,
2228.62134,127.598,3307.19336,129.840,
2228.71289,126.598,3307.28467,129.840,
2228.80444,127.598,3307.37622,129.840,
2228.89600,127.598,3307.46777,129.840,
2228.98755,127.598,3307.55933,129.840,
2229.07910,127.598,3307.65088,129.840,
2229.17041,128.598,3307.74243,129.840,
2229.26196,128.598,3307.83398,130.840,
2229.35352,128.598,3307.92529,130.840,
2229.44507,128.598,3308.01685,130.840,
2229.53662,128.598,3308.10840,130.840,
2229.62817,129.598,3308.19995,130.840,
2229.71973,128.598,3308.29150,130.840,
2229.81128,128.598,3308.38306,130.840,
2229.90259,128.598,3308.47461,130.840,
2229.99414,127.598,3308.56616,130.840,
2230.08569,127.598,3308.65747,130.840,
2230.17725,127.598,3308.74902,131.840,
2230.26880,127.598,3308.84058,131.840,
2230.36035,128.598,3308.93213,130.840,
2230.45190,128.598,3309.02368,131.840,
2230.54321,127.598,3309.11523,131.840,
2230.63477,127.598,3309.20679,131.840,
2230.72632,127.598,3309.29834,131.840,
2230.81787,127.598,3309.38965,131.840,
2230.90942,127.598,3309.48120,131.840,
2231.00098,127.598,3309.57275,131.840,
2231.09253,127.598,3309.66431,132.840,
2231.18408,127.598,3309.75586,131.840,
2231.27539,127.598,3309.84741,132.840,
2231.36694,126.598,3309.93896,132.840,
2231.45850,126.598,3310.03027,131.840,
2231.55005,125.598,3310.12183,131.840,
2231.64160,125.598,3310.21338,132.840,
2231.73315,125.598,3310.30493,132.840,
2231.82471,124.598,3310.39648,131.840,
2231.91626,124.598,3310.48804,131.840,
2232.00757,124.598,3310.57959,131.840,
2232.09912,124.598,3310.67114,131.840,
2232.19067,124.598,3310.76245,131.840,
2232.28223,124.598,3310.85400,131.840,
2232.37378,125.598,3310.94556,131.840,
2232.46533,124.598,3311.03711,131.840,
2232.55688,126.598,3311.12866,131.840,
2232.64819,125.598,3311.22021,131.840,
2232.73975,125.598,3311.31177,131.840,
2232.83130,126.598,3311.40332,132.840,
2232.92285,126.598,3311.49463,132.840,
2233.01440,127.598,3311.58618,132.840,
2233.10596,127.598,3311.67773,131.840,
2233.19751,127.598,3311.76929,133.840,
2233.28906,127.598,3311.86084,132.840,
2233.38037,127.598,3311.95239,132.840,
2233.47192,127.598,3312.04395,132.840,
2233.56348,128.598,3312.13525,132.840,
2233.65503,127.598,3312.22681,132.840,
2233.74658,127.598,3312.31836,132.840,
2233.83813,128.598,3312.40991,133.840,
2233.92969,128.598,3312.50146,132.840,
2234.02124,128.598,3312.59302,132.840,
2234.11255,128.598,3312.68457,132.840,
2234.20410,128.598,3312.77612,133.840,
2234.29565,128.598,3312.86743,132.840,
2234.38721,129.598,3312.95898,133.840,
2234.47876,128.598,3313.05054,133.840,
2234.57031,129.598,3313.14209,133.840,
2234.66187,129.598,3313.23364,134.840,
2234.75317,129.598,3313.32520,133.840,
2234.84473,129.598,3313.41675,133.840,
2234.93628,128.598,3313.50830,133.840,
2235.02783,129.598,3313.59961,134.840,
2235.11938,129.598,3313.69116,133.840,
2235.21094,129.598,3313.78271,134.840,
2235.30249,129.598,3313.87427,133.840,
2235.39404,129.598,3313.96582,134.840,
2235.48535,130.598,3314.05737,133.840,
2235.57690,129.598,3314.14893,133.840,
2235.66846,130.598,3314.24023,134.840,
2235.76001,129.598,3314.33179,133.840,
2235.85156,129.598,3314.42334,133.840,
2235.94312,129.598,3314.51489,134.840,
2236.03467,130.598,3314.60645,134.840,
2236.12598,129.598,3314.69800,134.840,
2236.21753,129.598,3314.78955,134.840,
2236.30908,130.598,3314.88110,134.840,
2236.40063,129.598,3314.97241,134.840,
2236.49219,130.598,3315.06396,134.840,
2236.58374,129.598,3315.15552,134.840,
2236.67529,129.598,3315.24707,134.840,
2236.76685,129.598,3315.33862,134.840,
2236.85815,129.598,3315.43018,134.840,
2236.94971,130.598,3315.52173,135.840,
2237.04126,129.598,3315.61304,134.840,
2237.13281,130.598,3315.70459,134.840,
2237.22437,130.598,3315.79614,135.840,
2237.31592,130.598,3315.88770,134.840,
2237.40747,130.598,3315.97925,135.840,
2237.49902,130.598,3316.07080,135.840,
2237.59033,130.598,3316.16235,135.840,
2237.68188,130.598,3316.25391,135.840,
2237.77344,130.598,3316.34521,135.840,
2237.86499,130.598,3316.43677,135.840,
2237.95654,130.598,3316.52832,135.840,
2238.04810,130.598,3316.61987,135.840,
2238.13965,130.598,3316.71143,135.840,
2238.23096,130.598,3316.80298,136.840,
2238.32251,130.598,3316.89453,136.840,
2238.41406,130.598,3316.98608,135.840,
2238.50562,130.598,3317.07739,135.840,
2238.59717,130.598,3317.16895,135.840,
2238.68872,130.598,3317.26050,136.840,
2238.78027,130.598,3317.35205,135.840,
2238.87183,130.598,3317.44360,135.840,
2238.96313,130.598,3317.53516,136.840,
2239.05469,131.598,3317.62671,136.840,
2239.14624,130.598,3317.71802,136.840,
2239.23779,130.598,3317.80957,136.840,
2239.32935,130.598,3317.90112,136.840,
2239.42090,130.598,3317.99268,136.840,
2239.51245,130.598,3318.08423,136.840,
2239.60400,130.598,3318.17578,136.840,
2239.69531,131.598,3318.26733,136.840,
2239.78687,130.598,3318.35889,136.840,
2239.87842,131.598,3318.45020,136.840,
2239.96997,131.598,3318.54175,136.840,
2240.06152,131.598,3318.63330,136.840,
2240.15308,130.598,3318.72485,136.840,
2240.24463,131.598,3318.81641,136.840,
2240.33594,131.598,3318.90796,137.840,
2240.42749,131.598,3318.99951,137.840,
2240.51904,131.598,3319.09106,137.840,
2240.61060,131.598,3319.18237,137.840,
2240.70215,131.598,3319.27393,136.840,
2240.79370,131.598,3319.36548,137.840,
2240.88525,131.598,3319.45703,137.840,
2240.97681,131.598,3319.54858,137.840,
2241.06812,131.598,3319.64014,137.840,
2241.15967,131.598,3319.73169,137.840,
2241.25122,131.598,3319.82300,137.840,
2241.34277,132.598,3319.91455,137.840,
2241.43433,131.598,3320.00610,137.840,
2241.52588,131.598,3320.09766,137.840,
2241.61743,131.598,3320.18921,137.840,
2241.70874,131.598,3320.28076,137.840,
2241.80029,132.598,3320.37231,138.840,
2241.89185,132.598,3320.46387,137.840,
2241.98340,131.598,3320.55518,138.840,
2242.07495,131.598,3320.64673,137.840,
2242.16650,132.598,3320.73828,138.840,
2242.25806,131.598,3320.82983,138.840,
2242.34961,132.598,3320.92139,138.840,
2242.44092,132.598,3321.01294,138.840,
2242.53247,132.598,3321.10449,138.840,
2242.62402,132.598,3321.19580,138.840,
2242.71558,132.598,3321.28735,138.840,
2242.80713,133.598,3321.37891,137.840,
2242.89868,132.598,3321.47046,137.840,
2242.99023,132.598,3321.56201,138.840,
2243.08179,132.598,3321.65356,138.840,
2243.17310,132.598,3321.74512,138.840,
2243.26465,132.598,3321.83667,138.840,
2243.35620,132.598,3321.92798,138.840,
2243.44775,133.598,3322.01953,139.840,
2243.53931,132.598,3322.11108,138.840,
2243.63086,133.598,3322.20264,139.840,
2243.72241,132.598,3322.29419,138.840,
2243.81372,132.598,3322.38574,138.840,
2243.90527,133.598,3322.47729,138.840,
2243.99683,132.598,3322.56885,139.840,
2244.08838,132.598,3322.66016,138.840,
2244.17993,133.598,3322.75171,138.840,
2244.27148,133.598,3322.84326,139.840,
2244.36304,133.598,3322.93481,139.840,
2244.45459,132.598,3323.02637,139.840,
2244.54590,133.598,3323.11792,139.840,
2244.63745,133.598,3323.20947,139.840,
2244.72900,132.598,3323.30078,139.840,
2244.82056,133.598,3323.39233,140.840,
2244.91211,133.598,3323.48389,140.840,
2245.00366,133.598,3323.57544,139.840,
2245.09521,133.598,3323.66699,139.840,
2245.18677,133.598,3323.75854,139.840,
2245.27808,133.598,3323.85010,139.840,
2245.36963,133.598,3323.94165,139.840,
2245.46118,133.598,3324.03296,139.840,
2245.55273,133.598,3324.12451,139.840,
2245.64429,133.598,3324.21606,140.840,
2245.73584,134.598,3324.30762,139.840,
2245.82739,134.598,3324.39917,140.840,
2245.91870,133.598,3324.49072,139.840,
2246.01025,133.598,3324.58228,140.840,
2246.10181,134.598,3324.67383,140.840,
2246.19336,134.598,3324.76514,140.840,
2246.28491,134.598,3324.85669,140.840,
2246.37646,134.598,3324.94824,141.840,
2246.46802,134.598,3325.03979,140.840,
2246.55957,133.598,3325.13135,140.840,
2246.65088,133.598,3325.22290,140.840,
2246.74243,133.598,3325.31445,140.840,
2246.83398,133.598,3325.40576,140.840,
2246.92554,132.598,3325.49731,139.840,
2247.01709,132.598,3325.58887,140.840,
2247.10864,131.598,3325.68042,140.840,
2247.20020,132.598,3325.77197,140.840,
2247.29175,132.598,3325.86353,140.840,
2247.38306,132.598,3325.95508,140.840,
2247.47461,132.598,3326.04663,140.840,
2247.56616,132.598,3326.13794,141.840,
2247.65771,133.598,3326.22949,140.840,
2247.74927,133.598,3326.32104,141.840,
2247.84082,132.598,3326.41260,141.840,
2247.93237,133.598,3326.50415,141.840,
2248.02368,133.598,3326.59570,141.840,
2248.11523,133.598,3326.68726,141.840,
2248.20679,133.598,3326.77856,141.840,
2248.29834,133.598,3326.87012,141.840,
2248.38989,133.598,3326.96167,141.840,
2248.48145,133.598,3327.05322,142.840,
2248.57300,134.598,3327.14478,141.840,
2248.66455,134.598,3327.23633,142.840,
2248.75586,134.598,3327.32788,141.840,
2248.84741,134.598,3327.41943,142.840,
2248.93896,135.598,3327.51074,142.840,
2249.03052,134.598,3327.60229,142.840,
2249.12207,134.598,3327.69385,143.840,
2249.21362,133.598,3327.78540,142.840,
2249.30518,132.598,3327.87695,143.840,
2249.39648,132.598,3327.96851,142.840,
2249.48804,132.598,3328.06006,142.840,
2249.57959,132.598,3328.15161,142.840,
2249.67114,132.598,3328.24292,142.840,
2249.76270,133.598,3328.33447,142.840,
2249.85425,132.598,3328.42603,141.840,
2249.94580,133.598,3328.51758,141.840,
2250.03735,133.598,3328.60913,142.840,
2250.12866,134.598,3328.70068,142.840,
2250.22021,134.598,3328.79224,141.840,
2250.31177,134.598,3328.88354,142.840,
2250.40332,134.598,3328.97510,142.840,
2250.49487,134.598,3329.06665,142.840,
2250.58643,134.598,3329.15820,143.840,
2250.67798,135.598,3329.24976,143.840,
2250.76953,135.598,3329.34131,144.840,
2250.86084,135.598,3329.43286,143.840,
2250.95239,135.598,3329.52441,144.840,
2251.04395,135.598,3329.61572,143.840,
2251.13550,135.598,3329.70728,143.840,
2251.22705,135.598,3329.79883,144.840,
2251.31860,136.598,3329.89038,144.840,
2251.41016,136.598,3329.98193,143.840,
2251.50146,136.598,3330.07349,143.840,
2251.59302,136.598,3330.16504,144.840,
2251.68457,136.598,3330.25659,144.840,
2251.77612,136.598,3330.34790,143.840,
2251.86768,136.598,3330.43945,144.840,
2251.95923,136.598,3330.53101,145.840,
2252.05078,136.598,3330.62256,144.840,
2252.14233,136.598,3330.71411,144.840,
2252.23364,136.598,3330.80566,145.840,
2252.32520,136.598,3330.89722,144.840,
2252.41675,137.598,3330.98853,144.840,
2252.50830,136.598,3331.08008,144.840,
2252.59985,137.598,3331.17163,144.840,
2252.69141,136.598,3331.26318,144.840,
2252.78296,137.598,3331.35474,145.840,
2252.87451,137.598,3331.44629,144.840,
2252.96582,137.598,3331.53784,144.840,
2253.05737,137.598,3331.62939,144.840,
2253.14893,137.598,3331.72070,144.840,
2253.24048,137.598,3331.81226,144.840,
2253.33203,136.598,3331.90381,145.840,
2253.42358,137.598,3331.99536,145.840,
2253.51514,137.598,3332.08691,145.840,
2253.60645,137.598,3332.17847,144.840,
2253.69800,137.598,3332.27002,145.840,
2253.78955,137.598,3332.36157,145.840,
2253.88110,137.598,3332.45288,144.840,
2253.97266,137.598,3332.54443,145.840,
2254.06421,137.598,3332.63599,145.840,
2254.15576,137.598,3332.72754,145.840,
2254.24731,137.598,3332.81909,145.840,
2254.33862,138.598,3332.91064,145.840,
2254.43018,137.598,3333.00220,145.840,
2254.52173,138.598,3333.09351,145.840,
2254.61328,137.598,3333.18506,146.840,
2254.70483,138.598,3333.27661,145.840,
2254.79639,138.598,3333.36816,145.840,
2254.88794,137.598,3333.45972,145.840,
2254.97925,137.598,3333.55127,145.840,
2255.07080,138.598,3333.64282,145.840,
2255.16235,138.598,3333.73438,146.840,
2255.25391,138.598,3333.82568,146.840,
2255.34546,137.598,3333.91724,145.840,
2255.43701,138.598,3334.00879,145.840,
2255.52856,137.598,3334.10034,146.840,
2255.62012,138.598,3334.19189,146.840,
2255.71143,138.598,3334.28345,146.840,
2255.80298,137.598,3334.37500,146.840,
2255.89453,138.598,3334.46631,146.840,
2255.98608,139.598,3334.55786,146.840,
2256.07764,138.598,3334.64941,146.840,
2256.16919,138.598,3334.74097,146.840,
2256.26074,139.598,3334.83252,146.840,
2256.35229,138.598,3334.92407,146.840,
2256.44360,138.598,3335.01563,147.840,
2256.53516,138.598,3335.10718,146.840,
2256.62671,138.598,3335.19849,147.840,
2256.71826,138.598,3335.29004,147.840,
2256.80981,139.598,3335.38159,146.840,
2256.90137,139.598,3335.47314,147.840,
2256.99292,138.598,3335.56470,147.840,
2257.08423,138.598,3335.65625,147.840,
2257.17578,138.598,3335.74780,147.840,
2257.26733,138.598,3335.83936,147.840,
2257.35889,138.598,3335.93066,147.840,
2257.45044,139.598,3336.02222,147.840,
2257.54199,139.598,3336.11377,147.840,
2257.63354,138.598,3336.20532,147.840,
2257.72510,138.598,3336.29688,147.840,
2257.81641,139.598,3336.38843,148.840,
2257.90796,139.598,3336.47998,147.840,
2257.99951,139.598,3336.57129,148.840,
2258.09106,139.598,3336.66284,148.840,
2258.18262,139.598,3336.75439,148.840,
2258.27417,139.598,3336.84595,148.840,
2258.36572,139.598,3336.93750,148.840,
2258.45728,138.598,3337.02905,147.840,
2258.54858,139.598,3337.12061,148.840,
2258.64014,139.598,3337.21216,148.840,
2258.73169,139.598,3337.30347,148.840,
2258.82324,139.598,3337.39502,148.840,
2258.91479,140.598,3337.48657,148.840,
2259.00635,139.598,3337.57813,148.840,
2259.09790,139.598,3337.66968,149.840,
2259.18921,139.598,3337.76123,148.840,
2259.28076,139.598,3337.85278,148.840,
2259.37231,139.598,3337.94434,148.840,
2259.46387,140.598,3338.03564,149.840,
2259.55542,140.598,3338.12720,150.840,
2259.64697,139.598,3338.21875,149.840,
2259.73853,139.598,3338.31030,148.840,
2259.83008,139.598,3338.40186,149.840,
2259.92139,140.598,3338.49341,149.840,
2260.01294,140.598,3338.58496,148.840,
2260.10449,140.598,3338.67627,149.840,
2260.19604,139.598,3338.76782,149.840,
2260.28760,140.598,3338.85938,149.840,
2260.37915,140.598,3338.95093,149.840,
2260.47070,140.598,3339.04248,149.840,
2260.56201,140.598,3339.13403,149.840,
2260.65356,140.598,3339.22559,149.840,
2260.74512,140.598,3339.31714,149.840,
2260.83667,140.598,3339.40845,149.840,
2260.92822,140.598,3339.50000,149.840,
2261.01978,140.598,3339.59155,150.840,
2261.11133,140.598,3339.68311,149.840,
2261.20288,140.598,3339.77466,149.840,
2261.29419,139.598,3339.86621,150.840,
2261.38574,140.598,3339.95776,150.840,
2261.47729,140.598,3340.04907,149.840,
2261.56885,140.598,3340.14063,150.840,
2261.66040,140.598,3340.23218,150.840,
2261.75195,141.598,3340.32373,150.840,
2261.84351,141.598,3340.41528,149.840,
2261.93506,140.598,3340.50684,150.840,
2262.02637,141.598,3340.59839,150.840,
2262.11792,141.598,3340.68994,150.840,
2262.20947,140.598,3340.78125,150.840,
2262.30103,141.598,3340.87280,150.840,
2262.39258,141.598,3340.96436,150.840,
2262.48413,140.598,3341.05591,151.840,
2262.57568,141.598,3341.14746,151.840,
2262.66699,140.598,3341.23901,151.840,
2262.75854,141.598,3341.33057,150.840,
2262.85010,141.598,3341.42212,150.840,
2262.94165,141.598,3341.51343,151.840,
2263.03320,141.598,3341.60498,151.840,
2263.12476,141.598,3341.69653,151.840,
2263.21631,141.598,3341.78809,151.840,
2263.30786,142.598,3341.87964,151.840,
2263.39917,141.598,3341.97119,151.840,
2263.49072,141.598,3342.06274,151.840,
2263.58228,142.598,3342.15405,151.840,
2263.67383,141.598,3342.24561,151.840,
2263.76538,141.598,3342.33716,151.840,
2263.85693,141.598,3342.42871,151.840,
2263.94849,142.598,3342.52026,152.840,
2264.04004,141.598,3342.61182,151.840,
2264.13135,141.598,3342.70337,151.840,
2264.22290,142.598,3342.79492,152.840,
2264.31445,142.598,3342.88623,151.840,
2264.40601,141.598,3342.97778,152.840,
2264.49756,142.598,3343.06934,151.840,
2264.58911,141.598,3343.16089,151.840,
2264.68066,142.598,3343.25244,152.840,
2264.77197,143.598,3343.34399,152.840,
2264.86353,143.598,3343.43555,151.840,
2264.95508,143.598,3343.52710,151.840,
2265.04663,142.598,3343.61841,151.840,
2265.13818,143.598,3343.70996,152.840,
2265.22974,143.598,3343.80151,152.840,
2265.32129,143.598,3343.89307,153.840,
2265.41284,144.598,3343.98462,152.840,
2265.50415,143.598,3344.07617,152.840,
2265.59570,144.598,3344.16772,152.840,
2265.68726,144.598,3344.25903,152.840,
2265.77881,143.598,3344.35059,152.840,
2265.87036,144.598,3344.44214,153.840,
2265.96191,144.598,3344.53369,153.840,
2266.05347,144.598,3344.62524,153.840,
2266.14502,143.598,3344.71680,153.840,
2266.23633,144.598,3344.80835,153.840,
2266.32788,144.598,3344.89990,153.840,
2266.41943,143.598,3344.99121,153.840,
2266.51099,143.598,3345.08276,153.840,
2266.60254,143.598,3345.17432,153.840,
2266.69409,143.598,3345.26587,153.840,
2266.78564,143.598,3345.35742,153.840,
2266.87695,143.598,3345.44897,154.840,
2266.96851,143.598,3345.54053,154.840,
2267.06006,142.598,3345.63184,154.840,
2267.15161,143.598,3345.72339,154.840,
2267.24316,143.598,3345.81494,154.840,
2267.33472,143.598,3345.90649,154.840,
2267.42627,143.598,3345.99805,154.840,
2267.51782,143.598,3346.08960,155.840,
2267.60913,143.598,3346.18115,154.840,
2267.70068,144.598,3346.27271,154.840,
2267.79224,143.598,3346.36401,154.840,
2267.88379,144.598,3346.45557,154.840,
2267.97534,143.598,3346.54712,154.840,
2268.06689,144.598,3346.63867,155.840,
2268.15845,143.598,3346.73022,154.840,
2268.24976,143.598,3346.82178,154.840,
2268.34131,143.598,3346.91333,156.840,
2268.43286,143.598,3347.00488,155.840,
2268.52441,143.598,3347.09619,155.840,
2268.61597,142.598,3347.18774,154.840,
2268.70752,142.598,3347.27930,154.840,
2268.79907,143.598,3347.37085,155.840,
2268.89063,142.598,3347.46240,155.840,
2268.98193,143.598,3347.55396,155.840,
2269.07349,143.598,3347.64551,155.840,
2269.16504,143.598,3347.73682,154.840,
2269.25659,143.598,3347.82837,155.840,
2269.34814,143.598,3347.91992,155.840,
2269.43970,144.598,3348.01147,155.840,
2269.53125,143.598,3348.10303,155.840,
2269.62280,143.598,3348.19458,156.840,
2269.71411,144.598,3348.28613,155.840,
2269.80566,143.598,3348.37769,156.840,
2269.89722,143.598,3348.46899,155.840,
2269.98877,144.598,3348.56055,156.840,
2270.08032,144.598,3348.65210,155.840,
2270.17188,144.598,3348.74365,156.840,
2270.26343,144.598,3348.83521,156.840,
2270.35474,144.598,3348.92676,156.840,
2270.44629,144.598,3349.01831,156.840,
2270.53784,144.598,3349.10986,156.840,
2270.62939,145.598,3349.20117,156.840,
2270.72095,144.598,3349.29272,156.840,
2270.81250,144.598,3349.38428,156.840,
2270.90405,145.598,3349.47583,156.840,
2270.99561,145.598,3349.56738,156.840,
2271.08691,144.598,3349.65894,156.840,
2271.17847,144.598,3349.75049,157.840,
2271.27002,145.598,3349.84180,157.840,
2271.36157,144.598,3349.93335,156.840,
2271.45313,145.598,3350.02490,157.840,
2271.54468,145.598,3350.11646,157.840,
2271.63623,145.598,3350.20801,156.840,
2271.72778,145.598,3350.29956,157.840,
2271.81909,145.598,3350.39111,157.840,
2271.91064,145.598,3350.48267,157.840,
2272.00220,144.598,3350.57397,157.840,
2272.09375,145.598,3350.66553,157.840,
2272.18530,145.598,3350.75708,157.840,
2272.27686,145.598,3350.84863,157.840,
2272.36841,145.598,3350.94019,158.840,
2272.45972,145.598,3351.03174,157.840,
2272.55127,145.598,3351.12329,157.840,
2272.64282,145.598,3351.21484,158.840,
2272.73438,145.598,3351.30615,158.840,
2272.82593,145.598,3351.39771,158.840,
2272.91748,145.598,3351.48926,157.840,
2273.00903,145.598,3351.58081,158.840,
2273.10059,145.598,3351.67236,158.840,
2273.19189,145.598,3351.76392,158.840,
2273.28345,145.598,3351.85547,158.840,
2273.37500,145.598,3351.94678,158.840,
2273.46655,145.598,3352.03833,158.840,
2273.55811,146.598,3352.12988,158.840,
2273.64966,146.598,3352.22144,158.840,
2273.74121,145.598,3352.31299,158.840,
2273.83252,146.598,3352.40454,158.840,
2273.92407,146.598,3352.49609,158.840,
2274.01563,146.598,3352.58765,158.840,
2274.10718,146.598,3352.67896,159.840,
2274.19873,146.598,3352.77051,159.840,
2274.29028,146.598,3352.86206,159.840,
2274.38184,146.598,3352.95361,159.840,
2274.47339,146.598,3353.04517,159.840,
2274.56470,146.598,3353.13672,159.840,
2274.65625,145.598,3353.22827,159.840,
2274.74780,146.598,3353.31958,159.840,
2274.83936,146.598,3353.41113,159.840,
2274.93091,146.598,3353.50269,160.840,
2275.02246,146.598,3353.59424,159.840,
2275.11401,146.598,3353.68579,159.840,
2275.20557,146.598,3353.77734,160.840,
2275.29688,146.598,3353.86890,159.840,
2275.38843,146.598,3353.96045,159.840,
2275.47998,147.598,3354.05176,159.840,
2275.57153,146.598,3354.14331,160.840,
2275.66309,146.598,3354.23486,160.840,
2275.75464,147.598,3354.32642,160.840,
2275.84619,147.598,3354.41797,160.840,
2275.93750,146.598,3354.50952,160.840,
2276.02905,146.598,3354.60107,160.840,
2276.12061,146.598,3354.69263,160.840,
2276.21216,147.598,3354.78394,160.840,
2276.30371,146.598,3354.87549,161.840,
2276.39526,147.598,3354.96704,161.840,
2276.48682,147.598,3355.05859,160.840,
2276.57837,147.598,3355.15015,160.840,
2276.66968,147.598,3355.24170,161.840,
2276.76123,147.598,3355.33325,161.840,
2276.85278,147.598,3355.42456,160.840,
2276.94434,147.598,3355.51611,161.840,
2277.03589,147.598,3355.60767,161.840,
2277.12744,147.598,3355.69922,161.840,
2277.21899,147.598,3355.79077,161.840,
2277.31055,147.598,3355.88232,161.840,
2277.40186,147.598,3355.97388,161.840,
2277.49341,147.598,3356.06543,161.840,
2277.58496,147.598,3356.15674,161.840,
2277.67651,148.598,3356.24829,161.840,
2277.76807,147.598,3356.33984,161.840,
2277.85962,147.598,3356.43140,161.840,
2277.95117,148.598,3356.52295,162.840,
2278.04248,147.598,3356.61450,161.840,
2278.13403,148.598,3356.70605,161.840,
2278.22559,148.598,3356.79761,162.840,
2278.31714,148.598,3356.88892,162.840,
2278.40869,148.598,3356.98047,162.840,
2278.50024,148.598,3357.07202,162.840,
2278.59180,148.598,3357.16357,162.840,
2278.68335,148.598,3357.25513,162.840,
2278.77466,148.598,3357.34668,162.840,
2278.86621,148.598,3357.43823,162.840,
2278.95776,148.598,3357.52954,162.840,
2279.04932,148.598,3357.62109,162.840,
2279.14087,148.598,3357.71265,163.840,
2279.23242,148.598,3357.80420,162.840,
2279.32397,148.598,3357.89575,162.840,
2279.41528,149.598,3357.98730,162.840,
2279.50684,148.598,3358.07886,163.840,
2279.59839,148.598,3358.17041,162.840,
2279.68994,148.598,3358.26172,163.840,
2279.78149,148.598,3358.35327,163.840,
2279.87305,148.598,3358.44482,163.840,
2279.96460,148.598,3358.53638,163.840,
2280.05615,148.598,3358.62793,164.840,
2280.14746,149.598,3358.71948,163.840,
2280.23901,148.598,3358.81104,164.840,
2280.33057,148.598,3358.90234,164.840,
2280.42212,149.598,3358.99390,164.840,
2280.51367,149.598,3359.08545,164.840,
2280.60522,149.598,3359.17700,164.840,
2280.69678,149.598,3359.26855,164.840,
2280.78833,149.598,3359.36011,164.840,
2280.87964,149.598,3359.45166,163.840,
2280.97119,149.598,3359.54321,164.840,
2281.06274,149.598,3359.63452,164.840,
2281.15430,149.598,3359.72607,163.840,
2281.24585,149.598,3359.81763,164.840,
2281.33740,149.598,3359.90918,164.840,
2281.42896,149.598,3360.00073,164.840,
2281.52026,149.598,3360.09229,165.840,
2281.61182,150.598,3360.18384,165.840,
2281.70337,149.598,3360.27539,164.840,
2281.79492,149.598,3360.36670,165.840,
2281.88647,149.598,3360.45825,165.840,
2281.97803,149.598,3360.54980,164.840,
2282.06958,149.598,3360.64136,165.840,
2282.16113,149.598,3360.73291,165.840,
2282.25244,149.598,3360.82446,165.840,
2282.34399,150.598,3360.91602,165.840,
2282.43555,149.598,3361.00732,165.840,
2282.52710,150.598,3361.09888,165.840,
2282.61865,149.598,3361.19043,165.840,
2282.71021,149.598,3361.28198,165.840,
2282.80176,149.598,3361.37354,165.840,
2282.89331,150.598,3361.46509,165.840,
2282.98462,150.598,3361.55664,165.840,
2283.07617,149.598,3361.64819,165.840,
2283.16772,149.598,3361.73950,165.840,
2283.25928,149.598,3361.83105,165.840,
2283.35083,149.598,3361.92261,165.840,
2283.44238,148.598,3362.01416,166.840,
2283.53394,148.598,3362.10571,166.840,
2283.62524,148.598,3362.19727,165.840,
2283.71680,148.598,3362.28882,166.840,
2283.80835,149.598,3362.38037,166.840,
2283.89990,148.598,3362.47168,166.840,
2283.99146,148.598,3362.56323,166.840,
2284.08301,148.598,3362.65479,166.840,
2284.17456,148.598,3362.74634,166.840,
2284.26611,149.598,3362.83789,166.840,
2284.35742,149.598,3362.92944,166.840,
2284.44897,149.598,3363.02100,167.840,
2284.54053,149.598,3363.11230,166.840,
2284.63208,149.598,3363.20386,167.840,
2284.72363,150.598,3363.29541,167.840,
2284.81519,150.598,3363.38696,167.840,
2284.90674,150.598,3363.47852,167.840,
2284.99829,150.598,3363.57007,167.840,
2285.08960,150.598,3363.66162,166.840,
2285.18115,150.598,3363.75317,167.840,
2285.27271,151.598,3363.84448,167.840,
2285.36426,150.598,3363.93604,167.840,
2285.45581,150.598,3364.02759,167.840,
2285.54736,150.598,3364.11914,167.840,
2285.63892,149.598,3364.21069,167.840,
2285.73022,148.598,3364.30225,167.840,
2285.82178,148.598,3364.39380,167.840,
2285.91333,148.598,3364.48511,168.840,
2286.00488,148.598,3364.57666,167.840,
2286.09644,147.598,3364.66821,167.840,
2286.18799,148.598,3364.75977,168.840,
2286.27954,148.598,3364.85132,168.840,
2286.37109,148.598,3364.94287,168.840,
2286.46240,149.598,3365.03442,168.840,
2286.55396,149.598,3365.12598,168.840,
2286.64551,149.598,3365.21729,168.840,
2286.73706,150.598,3365.30884,168.840,
2286.82861,151.598,3365.40039,168.840,
2286.92017,150.598,3365.49194,168.840,
2287.01172,150.598,3365.58350,169.840,
2287.10303,151.598,3365.67505,168.840,
2287.19458,151.598,3365.76660,169.840,
2287.28613,151.598,3365.85815,168.840,
2287.37769,152.598,3365.94946,170.840,
2287.46924,151.598,3366.04102,168.840,
2287.56079,151.598,3366.13257,169.840,
2287.65234,152.598,3366.22412,169.840,
2287.74390,152.598,3366.31567,169.840,
2287.83521,151.598,3366.40723,169.840,
2287.92676,151.598,3366.49878,169.840,
2288.01831,152.598,3366.59009,169.840,
2288.10986,152.598,3366.68164,169.840,
2288.20142,153.598,3366.77319,169.840,
2288.29297,152.598,3366.86475,169.840,
2288.38452,152.598,3366.95630,169.840,
2288.47607,152.598,3367.04785,169.840,
2288.56738,152.598,3367.13940,169.840,
2288.65894,153.598,3367.23096,170.840,
2288.75049,152.598,3367.32227,169.840,
2288.84204,152.598,3367.41382,170.840,
2288.93359,152.598,3367.50537,170.840,
2289.02515,152.598,3367.59692,170.840,
2289.11670,152.598,3367.68848,170.840,
2289.20801,153.598,3367.78003,170.840,
2289.29956,153.598,3367.87158,170.840,
2289.39111,152.598,3367.96313,169.840,
2289.48267,152.598,3368.05444,170.840,
2289.57422,152.598,3368.14600,171.840,
2289.66577,153.598,3368.23755,170.840,
2289.75732,153.598,3368.32910,170.840,
2289.84888,153.598,3368.42065,171.840,
2289.94019,153.598,3368.51221,170.840,
2290.03174,152.598,3368.60376,170.840,
2290.12329,153.598,3368.69507,171.840,
2290.21484,153.598,3368.78662,171.840,
2290.30640,153.598,3368.87817,171.840,
2290.39795,153.598,3368.96973,171.840,
2290.48950,153.598,3369.06128,172.840,
2290.58105,153.598,3369.15283,171.840,
2290.67236,153.598,3369.24438,171.840,
2290.76392,153.598,3369.33594,171.840,
2290.85547,153.598,3369.42725,171.840,
2290.94702,153.598,3369.51880,171.840,
2291.03857,153.598,3369.61035,171.840,
2291.13013,154.598,3369.70190,171.840,
2291.22168,153.598,3369.79346,171.840,
2291.31299,153.598,3369.88501,172.840,
2291.40454,153.598,3369.97656,172.840,
2291.49609,154.598,3370.06787,172.840,
2291.58765,154.598,3370.15942,172.840,
2291.67920,153.598,3370.25098,172.840,
2291.77075,154.598,3370.34253,173.840,
2291.86230,154.598,3370.43408,172.840,
2291.95386,153.598,3370.52563,172.840,
2292.04517,154.598,3370.61719,172.840,
2292.13672,154.598,3370.70874,172.840,
2292.22827,154.598,3370.80005,173.840,
2292.31982,154.598,3370.89160,172.840,
2292.41138,154.598,3370.98315,172.840,
2292.50293,154.598,3371.07471,173.840,
2292.59448,154.598,3371.16626,172.840,
2292.68579,154.598,3371.25781,173.840,
2292.77734,154.598,3371.34937,173.840,
2292.86890,154.598,3371.44092,173.840,
2292.96045,154.598,3371.53223,173.840,
2293.05200,155.598,3371.62378,173.840,
2293.14355,154.598,3371.71533,173.840,
2293.23511,155.598,3371.80688,174.840,
2293.32666,154.598,3371.89844,173.840,
2293.41797,154.598,3371.98999,173.840,
2293.50952,155.598,3372.08154,174.840,
2293.60107,155.598,3372.17285,173.840,
2293.69263,155.598,3372.26440,173.840,
2293.78418,155.598,3372.35596,174.840,
2293.87573,155.598,3372.44751,174.840,
2293.96729,154.598,3372.53906,173.840,
2294.05884,155.598,3372.63062,174.840,
2294.15015,155.598,3372.72217,174.840,
2294.24170,155.598,3372.81372,173.840,
2294.33325,155.598,3372.90503,173.840,
2294.42480,155.598,3372.99658,174.840,
2294.51636,155.598,3373.08813,174.840,
2294.60791,155.598,3373.17969,174.840,
2294.69946,155.598,3373.27124,175.840,
2294.79077,155.598,3373.36279,175.840,
2294.88232,155.598,3373.45435,174.840,
2294.97388,155.598,3373.54590,174.840,
2295.06543,155.598,3373.63721,174.840,
2295.15698,155.598,3373.72876,175.840,
2295.24854,155.598,3373.82031,175.840,
2295.34009,155.598,3373.91187,175.840,
2295.43164,155.598,3374.00342,175.840,
2295.52295,155.598,3374.09497,175.840,
2295.61450,155.598,3374.18652,175.840,
2295.70605,155.598,3374.27783,175.840,
2295.79761,155.598,3374.36938,175.840,
2295.88916,156.598,3374.46094,175.840,
2295.98071,156.598,3374.55249,175.840,
2296.07227,156.598,3374.64404,175.840,
2296.16382,156.598,3374.73560,176.840,
2296.25513,156.598,3374.82715,175.840,
2296.34668,156.598,3374.91870,176.840,
2296.43823,155.598,3375.01001,175.840,
2296.52979,155.598,3375.10156,175.840,
2296.62134,156.598,3375.19312,176.840,
2296.71289,156.598,3375.28467,176.840,
2296.80444,156.598,3375.37622,176.840,
2296.89575,156.598,3375.46777,176.840,
2296.98730,157.598,3375.55933,176.840,
2297.07886,156.598,3375.65088,176.840,
2297.17041,156.598,3375.74219,176.840,
2297.26196,156.598,3375.83374,176.840,
2297.35352,156.598,3375.92529,176.840,
2297.44507,156.598,3376.01685,176.840,
2297.53662,156.598,3376.10840,176.840,
2297.62793,157.598,3376.19995,177.840,
2297.71948,156.598,3376.29150,176.840,
2297.81104,156.598,3376.38281,177.840,
2297.90259,156.598,3376.47437,176.840,
2297.99414,156.598,3376.56592,177.840,
2298.08569,156.598,3376.65747,177.840,
2298.17725,157.598,3376.74902,177.840,
2298.26855,156.598,3376.84058,177.840,
2298.36011,157.598,3376.93213,177.840,
2298.45166,157.598,3377.02368,177.840,
2298.54321,157.598,3377.11499,177.840,
2298.63477,157.598,3377.20654,177.840,
2298.72632,157.598,3377.29810,177.840,
2298.81787,157.598,3377.38965,177.840,
2298.90942,157.598,3377.48120,177.840,
2299.00073,157.598,3377.57275,177.840,
2299.09229,157.598,3377.66431,178.840,
2299.18384,157.598,3377.75562,177.840,
2299.27539,156.598,3377.84717,177.840,
2299.36694,157.598,3377.93872,178.840,
2299.45850,157.598,3378.03027,177.840,
2299.55005,157.598,3378.12183,177.840,
2299.64160,158.598,3378.21338,178.840,
2299.73291,157.598,3378.30493,178.840,
2299.82446,157.598,3378.39648,178.840,
2299.91602,158.598,3378.48779,179.840,
2300.00757,158.598,3378.57935,178.840,
2300.09912,158.598,3378.67090,178.840,
2300.19067,158.598,3378.76245,179.840,
2300.28223,157.598,3378.85400,179.840,
2300.37354,158.598,3378.94556,179.840,
2300.46509,158.598,3379.03711,179.840,
2300.55664,158.598,3379.12866,180.840,
2300.64819,158.598,3379.21997,179.840,
2300.73975,158.598,3379.31152,179.840,
2300.83130,158.598,3379.40308,179.840,
2300.92285,158.598,3379.49463,179.840,
2301.01440,158.598,3379.58618,179.840,
2301.10571,158.598,3379.67773,179.840,
2301.19727,157.598,3379.76929,179.840,
2301.28882,157.598,3379.86060,179.840,
2301.38037,158.598,3379.95215,180.840,
2301.47192,157.598,3380.04370,179.840,
2301.56348,157.598,3380.13525,179.840,
2301.65503,157.598,3380.22681,179.840,
2301.74658,157.598,3380.31836,179.840,
2301.83789,157.598,3380.40991,179.840,
2301.92944,158.598,3380.50146,180.840,
2302.02100,157.598,3380.59277,180.840,
2302.11255,158.598,3380.68433,180.840,
2302.20410,158.598,3380.77588,180.840,
2302.29565,158.598,3380.86743,180.840,
2302.38721,158.598,3380.95898,180.840,
2302.47852,158.598,3381.05054,180.840,
2302.57007,158.598,3381.14209,179.840,
2302.66162,158.598,3381.23364,179.840,
2302.75317,159.598,3381.32495,179.840,
2302.84473,159.598,3381.41650,179.840,
2302.93628,159.598,3381.50806,179.840,
2303.02783,160.598,3381.59961,180.840,
2303.11938,159.598,3381.69116,179.840,
2303.21069,159.598,3381.78271,179.840,
2303.30225,159.598,3381.87427,179.840,
2303.39380,159.598,3381.96558,180.840,
2303.48535,160.598,3382.05713,181.840,
2303.57690,160.598,3382.14868,180.840,
2303.66846,161.598,3382.24023,181.840,
2303.76001,161.598,3382.33179,181.840,
2303.85132,162.598,3382.42334,181.840,
2303.94287,163.598,3382.51489,181.840,
2304.03442,163.598,3382.60645,181.840,
2304.12598,163.598,3382.69775,182.840,
2304.21753,163.598,3382.78931,181.840,
2304.30908,164.598,3382.88086,182.840,
2304.40063,164.598,3382.97241,181.840,
2304.49219,163.598,3383.06396,182.840,
2304.58350,163.598,3383.15552,182.840,
2304.67505,163.598,3383.24707,182.840,
2304.76660,162.598,3383.33838,182.840,
2304.85815,162.598,3383.42993,182.840,
2304.94971,162.598,3383.52148,183.840,
2305.04126,161.598,3383.61304,182.840,
2305.13281,161.598,3383.70459,182.840,
2305.22437,161.598,3383.79614,183.840,
2305.31567,161.598,3383.88770,182.840,
2305.40723,160.598,3383.97925,182.840,
2305.49878,161.598,3384.07056,183.840,
2305.59033,161.598,3384.16211,183.840,
2305.68188,160.598,3384.25366,183.840,
2305.77344,161.598,3384.34521,183.840,
2305.86499,161.598,3384.43677,183.840,
2305.95630,160.598,3384.52832,183.840,
2306.04785,160.598,3384.61987,183.840,
2306.13940,161.598,3384.71143,183.840,
2306.23096,160.598,3384.80273,183.840,
2306.32251,160.598,3384.89429,183.840,
2306.41406,160.598,3384.98584,183.840,
2306.50562,161.598,3385.07739,183.840,
2306.59717,161.598,3385.16895,184.840,
2306.68848,161.598,3385.26050,183.840,
2306.78003,161.598,3385.35205,183.840,
2306.87158,161.598,3385.44336,183.840,
2306.96313,161.598,3385.53491,184.840,
2307.05469,161.598,3385.62646,184.840,
2307.14624,161.598,3385.71802,183.840,
2307.23779,161.598,3385.80957,184.840,
2307.32935,161.598,3385.90112,183.840,
2307.42065,161.598,3385.99268,183.840,
2307.51221,161.598,3386.08423,184.840,
2307.60376,161.598,3386.17554,184.840,
2307.69531,162.598,3386.26709,183.840,
2307.78687,162.598,3386.35864,184.840,
2307.87842,161.598,3386.45020,184.840,
2307.96997,161.598,3386.54175,184.840,
2308.06128,161.598,3386.63330,184.840,
2308.15283,161.598,3386.72485,184.840,
2308.24438,161.598,3386.81641,184.840,
2308.33594,161.598,3386.90771,184.840,
2308.42749,161.598,3386.99927,185.840,
2308.51904,162.598,3387.09082,185.840,
2308.61060,161.598,3387.18237,185.840,
2308.70215,162.598,3387.27393,184.840,
2308.79346,162.598,3387.36548,185.840,
2308.88501,162.598,3387.45703,185.840,
2308.97656,162.598,3387.54834,185.840,
2309.06812,162.598,3387.63989,185.840,
2309.15967,162.598,3387.73145,185.840,
2309.25122,162.598,3387.82300,185.840,
2309.34277,162.598,3387.91455,186.840,
2309.43433,162.598,3388.00610,186.840,
2309.52563,162.598,3388.09766,186.840,
2309.61719,162.598,3388.18921,185.840,
2309.70874,162.598,3388.28052,186.840,
2309.80029,162.598,3388.37207,186.840,
2309.89185,162.598,3388.46362,185.840,
2309.98340,162.598,3388.55518,185.840,
2310.07495,162.598,3388.64673,185.840,
2310.16626,163.598,3388.73828,186.840,
2310.25781,162.598,3388.82983,186.840,
2310.34937,163.598,3388.92114,186.840,
2310.44092,163.598,3389.01270,185.840,
2310.53247,163.598,3389.10425,186.840,
2310.62402,163.598,3389.19580,186.840,
2310.71558,163.598,3389.28735,186.840,
2310.80713,162.598,3389.37891,187.840,
2310.89844,163.598,3389.47046,186.840,
2310.98999,163.598,3389.56201,187.840,
2311.08154,163.598,3389.65332,187.840,
2311.17310,162.598,3389.74487,186.840,
2311.26465,163.598,3389.83643,187.840,
2311.35620,162.598,3389.92798,187.840,
2311.44775,163.598,3390.01953,187.840,
2311.53906,162.598,3390.11108,187.840,
2311.63062,164.598,3390.20264,187.840,
2311.72217,163.598,3390.29419,186.840,
2311.81372,163.598,3390.38550,186.840,
2311.90527,163.598,3390.47705,187.840,
2311.99683,163.598,3390.56860,187.840,
2312.08838,163.598,3390.66016,187.840,
2312.17993,163.598,3390.75171,187.840,
2312.27124,163.598,3390.84326,188.840,
2312.36279,163.598,3390.93481,187.840,
2312.45435,163.598,3391.02612,187.840,
2312.54590,163.598,3391.11768,187.840,
2312.63745,163.598,3391.20923,187.840,
2312.72900,163.598,3391.30078,187.840,
2312.82056,163.598,3391.39233,188.840,
2312.91211,164.598,3391.48389,188.840,
2313.00342,163.598,3391.57544,188.840,
2313.09497,164.598,3391.66699,188.840,
2313.18652,164.598,3391.75830,188.840,
2313.27808,163.598,3391.84985,188.840,
2313.36963,164.598,3391.94141,188.840,
2313.46118,164.598,3392.03296,188.840,
2313.55273,164.598,3392.12451,188.840,
2313.64404,164.598,3392.21606,188.840,
2313.73560,164.598,3392.30762,189.840,
2313.82715,164.598,3392.39917,189.840,
2313.91870,164.598,3392.49048,188.840,
2314.01025,164.598,3392.58203,189.840,
2314.10181,164.598,3392.67358,189.840,
2314.19336,164.598,3392.76514,189.840,
2314.28491,164.598,3392.85669,189.840,
2314.37622,164.598,3392.94824,189.840,
2314.46777,164.598,3393.03979,189.840,
2314.55933,164.598,3393.13110,188.840,
2314.65088,165.598,3393.22266,189.840,
2314.74243,164.598,3393.31421,189.840,
2314.83398,165.598,3393.40576,189.840,
2314.92554,164.598,3393.49731,189.840,
2315.01709,164.598,3393.58887,189.840,
2315.10840,165.598,3393.68042,189.840,
2315.19995,164.598,3393.77197,190.840,
2315.29150,165.598,3393.86328,189.840,
2315.38306,164.598,3393.95483,189.840,
2315.47461,164.598,3394.04639,190.840,
2315.56616,165.598,3394.13794,190.840,
2315.65771,165.598,3394.22949,190.840,
2315.74902,164.598,3394.32104,190.840,
2315.84058,165.598,3394.41260,190.840,
2315.93213,165.598,3394.50415,190.840,
2316.02368,166.598,3394.59546,190.840,
2316.11523,165.598,3394.68701,190.840,
2316.20679,165.598,3394.77856,190.840,
2316.29834,165.598,3394.87012,190.840,
2316.38989,165.598,3394.96167,190.840,
2316.48120,165.598,3395.05322,191.840,
2316.57275,165.598,3395.14478,191.840,
2316.66431,165.598,3395.23608,191.840,
2316.75586,165.598,3395.32764,191.840,
2316.84741,165.598,3395.41919,191.840,
2316.93896,165.598,3395.51074,191.840,
2317.03052,165.598,3395.60229,191.840,
2317.12183,166.598,3395.69385,191.840,
2317.21338,166.598,3395.78540,191.840,
2317.30493,166.598,3395.87695,191.840,
2317.39648,166.598,3395.96826,191.840,
2317.48804,166.598,3396.05981,191.840,
2317.57959,166.598,3396.15137,191.840,
2317.67114,166.598,3396.24292,192.840,
2317.76270,166.598,3396.33447,192.840,
2317.85400,166.598,3396.42603,191.840,
2317.94556,166.598,3396.51758,192.840,
2318.03711,166.598,3396.60889,192.840,
2318.12866,166.598,3396.70044,193.840,
2318.22021,166.598,3396.79199,192.840,
2318.31177,166.598,3396.88354,192.840,
2318.40332,166.598,3396.97510,192.840,
2318.49487,165.598,3397.06665,192.840,
2318.58618,166.598,3397.15820,193.840,
2318.67773,166.598,3397.24976,192.840,
2318.76929,166.598,3397.34106,193.840,
2318.86084,166.598,3397.43262,193.840,
2318.95239,167.598,3397.52417,193.840,
2319.04395,165.598,3397.61572,193.840,
2319.13550,166.598,3397.70728,193.840,
2319.22681,165.598,3397.79883,193.840,
2319.31836,165.598,3397.89038,193.840,
2319.40991,165.598,3397.98193,192.840,
2319.50146,164.598,3398.07324,193.840,
2319.59302,165.598,3398.16479,194.840,
2319.68457,164.598,3398.25635,193.840,
2319.77612,164.598,3398.34790,193.840,
2319.86768,165.598,3398.43945,193.840,
2319.95898,165.598,3398.53101,193.840,
2320.05054,165.598,3398.62256,193.840,
2320.14209,165.598,3398.71387,194.840,
2320.23364,165.598,3398.80542,194.840,
2320.32520,166.598,3398.89697,193.840,
2320.41675,166.598,3398.98853,193.840,
2320.50830,166.598,3399.08008,193.840,
2320.59985,166.598,3399.17163,192.840,
2320.69116,166.598,3399.26318,193.840,
2320.78271,167.598,3399.35474,193.840,
2320.87427,167.598,3399.44604,193.840,
2320.96582,167.598,3399.53760,193.840,
2321.05737,167.598,3399.62915,194.840,
2321.14893,167.598,3399.72070,193.840,
2321.24048,167.598,3399.81226,193.840,
2321.33179,168.598,3399.90381,193.840,
2321.42334,169.598,3399.99536,193.840,
2321.51489,169.598,3400.08691,194.840,
2321.60645,170.598,3400.17822,194.840,
2321.69800,170.598,3400.26978,194.840,
2321.78955,171.598,3400.36133,194.840,
2321.88110,172.598,3400.45288,194.840,
2321.97266,172.598,3400.54443,195.840,
2322.06396,173.598,3400.63599,194.840,
2322.15552,172.598,3400.72754,195.840,
2322.24707,172.598,3400.81885,195.840,
2322.33862,172.598,3400.91040,195.840,
2322.43018,172.598,3401.00195,195.840,
2322.52173,171.598,3401.09351,196.840,
2322.61328,171.598,3401.18506,196.840,
2322.70459,171.598,3401.27661,196.840,
2322.79614,171.598,3401.36816,195.840,
2322.88770,170.598,3401.45972,195.840,
2322.97925,170.598,3401.55103,196.840,
2323.07080,170.598,3401.64258,196.840,
2323.16235,170.598,3401.73413,196.840,
2323.25391,170.598,3401.82568,196.840,
2323.34546,170.598,3401.91724,196.840,
2323.43677,169.598,3402.00879,195.840,
2323.52832,169.598,3402.10034,196.840,
2323.61987,169.598,3402.19165,196.840,
2323.71143,169.598,3402.28320,196.840,
2323.80298,169.598,3402.37476,196.840,
2323.89453,169.598,3402.46631,196.840,
2323.98608,169.598,3402.55786,197.840,
2324.07764,169.598,3402.64941,196.840,
2324.16895,169.598,3402.74097,197.840,
2324.26050,169.598,3402.83252,197.840,
2324.35205,169.598,3402.92383,196.840,
2324.44360,169.598,3403.01538,197.840,
2324.53516,169.598,3403.10693,197.840,
2324.62671,169.598,3403.19849,197.840,
2324.71826,169.598,3403.29004,197.840,
2324.80957,170.598,3403.38159,197.840,
2324.90112,169.598,3403.47314,197.840,
2324.99268,169.598,3403.56470,197.840,
2325.08423,170.598,3403.65601,197.840,
2325.17578,169.598,3403.74756,197.840,
2325.26733,169.598,3403.83911,197.840,
2325.35889,169.598,3403.93066,197.840,
2325.45044,169.598,3404.02222,198.840,
2325.54175,170.598,3404.11377,197.840,
2325.63330,169.598,3404.20532,198.840,
2325.72485,170.598,3404.29663,198.840,
2325.81641,170.598,3404.38818,198.840,
2325.90796,170.598,3404.47974,198.840,
2325.99951,170.598,3404.57129,198.840,
2326.09106,170.598,3404.66284,198.840,
2326.18262,170.598,3404.75439,198.840,
2326.27393,170.598,3404.84595,198.840,
2326.36548,170.598,3404.93750,198.840,
2326.45703,170.598,3405.02881,198.840,
2326.54858,170.598,3405.12036,198.840,
2326.64014,171.598,3405.21191,198.840,
2326.73169,170.598,3405.30347,198.840,
2326.82324,170.598,3405.39502,198.840,
2326.91455,171.598,3405.48657,199.840,
2327.00610,170.598,3405.57813,198.840,
2327.09766,170.598,3405.66968,199.840,
2327.18921,170.598,3405.76099,198.840,
2327.28076,170.598,3405.85254,199.840,
2327.37231,171.598,3405.94409,199.840,
2327.46387,170.598,3406.03564,199.840,
2327.55542,171.598,3406.12720,199.840,
2327.64673,170.598,3406.21875,199.840,
2327.73828,171.598,3406.31030,199.840,
2327.82983,171.598,3406.40161,199.840,
2327.92139,171.598,3406.49316,199.840,
2328.01294,171.598,3406.58472,199.840,
2328.10449,171.598,3406.67627,199.840,
2328.19604,171.598,3406.76782,199.840,
2328.28760,171.598,3406.85938,199.840,
2328.37891,171.598,3406.95093,200.840,
2328.47046,171.598,3407.04248,200.840,
2328.56201,171.598,3407.13379,200.840,
2328.65356,171.598,3407.22534,199.840,
2328.74512,171.598,3407.31689,200.840,
2328.83667,171.598,3407.40845,200.840,
2328.92822,171.598,3407.50000,200.840,
2329.01953,171.598,3407.59155,200.840,
2329.11108,172.598,3407.68311,200.840,
2329.20264,172.598,3407.77441,200.840,
2329.29419,171.598,3407.86597,200.840,
2329.38574,171.598,3407.95752,200.840,
2329.47729,171.598,3408.04907,200.840,
2329.56885,172.598,3408.14063,200.840,
2329.66040,171.598,3408.23218,200.840,
2329.75171,172.598,3408.32373,200.840,
2329.84326,172.598,3408.41528,201.840,
2329.93481,171.598,3408.50659,200.840,
2330.02637,172.598,3408.59814,201.840,
2330.11792,171.598,3408.68970,201.840,
2330.20947,172.598,3408.78125,201.840,
2330.30103,172.598,3408.87280,201.840,
2330.39233,172.598,3408.96436,200.840,
2330.48389,171.598,3409.05591,201.840,
2330.57544,172.598,3409.14746,201.840,
2330.66699,173.598,3409.23877,201.840,
2330.75854,172.598,3409.33032,201.840,
2330.85010,172.598,3409.42188,202.840,
2330.94165,172.598,3409.51343,201.840,
2331.03320,172.598,3409.60498,201.840,
2331.12451,172.598,3409.69653,201.840,
2331.21606,172.598,3409.78809,202.840,
2331.30762,172.598,3409.87939,201.840,
2331.39917,172.598,3409.97095,202.840,
2331.49072,172.598,3410.06250,202.840,
2331.58228,173.598,3410.15405,202.840,
2331.67383,173.598,3410.24561,202.840,
2331.76538,173.598,3410.33716,203.840,
2331.85669,173.598,3410.42871,202.840,
2331.94824,173.598,3410.52026,202.840,
2332.03979,173.598,3410.61157,202.840,
2332.13135,174.598,3410.70313,202.840,
2332.22290,174.598,3410.79468,202.840,
2332.31445,173.598,3410.88623,203.840,
2332.40601,173.598,3410.97778,203.840,
2332.49731,173.598,3411.06934,202.840,
2332.58887,174.598,3411.16089,202.840,
2332.68042,173.598,3411.25244,203.840,
2332.77197,174.598,3411.34375,203.840,
2332.86353,174.598,3411.43530,203.840,
2332.95508,173.598,3411.52686,203.840,
2333.04663,174.598,3411.61841,203.840,
2333.13818,173.598,3411.70996,203.840,
2333.22949,173.598,3411.80151,203.840,
2333.32104,174.598,3411.89307,203.840,
2333.41260,173.598,3411.98438,204.840,
2333.50415,173.598,3412.07593,203.840,
2333.59570,174.598,3412.16748,203.840,
2333.68726,174.598,3412.25903,203.840,
2333.77881,173.598,3412.35059,203.840,
2333.87036,174.598,3412.44214,204.840,
2333.96167,173.598,3412.53369,204.840,
2334.05322,174.598,3412.62524,204.840,
2334.14478,173.598,3412.71655,203.840,
2334.23633,174.598,3412.80811,204.840,
2334.32788,174.598,3412.89966,203.840,
2334.41943,174.598,3412.99121,204.840,
2334.51099,174.598,3413.08276,204.840,
2334.60229,174.598,3413.17432,204.840,
2334.69385,174.598,3413.26587,204.840,
2334.78540,174.598,3413.35742,204.840,
2334.87695,174.598,3413.44873,204.840,
2334.96851,174.598,3413.54028,204.840,
2335.06006,174.598,3413.63184,204.840,
2335.15161,174.598,3413.72339,205.840,
2335.24316,175.598,3413.81494,204.840,
2335.33447,174.598,3413.90649,204.840,
2335.42603,175.598,3413.99805,204.840,
2335.51758,175.598,3414.08936,205.840,
2335.60913,174.598,3414.18091,204.840,
2335.70068,174.598,3414.27246,206.840,
2335.79224,175.598,3414.36401,205.840,
2335.88379,174.598,3414.45557,204.840,
2335.97510,174.598,3414.54712,205.840,
2336.06665,175.598,3414.63867,205.840,
2336.15820,175.598,3414.73022,205.840,
2336.24976,175.598,3414.82153,205.840,
2336.34131,175.598,3414.91309,205.840,
2336.43286,175.598,3415.00464,205.840,
2336.52441,175.598,3415.09619,205.840,
2336.61597,175.598,3415.18774,205.840,
2336.70728,176.598,3415.27930,205.840,
2336.79883,176.598,3415.37085,206.840,
2336.89038,177.598,3415.46216,205.840,
2336.98193,178.598,3415.55371,206.840,
2337.07349,178.598,3415.64526,206.840,
2337.16504,178.598,3415.73682,206.840,
2337.25659,178.598,3415.82837,206.840,
2337.34814,178.598,3415.91992,206.840,
2337.43945,179.598,3416.01147,206.840,
2337.53101,178.598,3416.10303,207.840,
2337.62256,178.598,3416.19434,207.840,
2337.71411,178.598,3416.28589,207.840,
2337.80566,178.598,3416.37744,207.840,
2337.89722,177.598,3416.46899,207.840,
2337.98877,177.598,3416.56055,207.840,
2338.08008,178.598,3416.65210,207.840,
2338.17163,177.598,3416.74365,207.840,
2338.26318,177.598,3416.83521,207.840,
2338.35474,177.598,3416.92651,207.840,
2338.44629,177.598,3417.01807,207.840,
2338.53784,177.598,3417.10962,208.840,
2338.62939,176.598,3417.20117,209.840,
2338.72095,176.598,3417.29272,208.840,
2338.81226,177.598,3417.38428,208.840,
2338.90381,177.598,3417.47583,207.840,
2338.99536,176.598,3417.56714,208.840,
2339.08691,176.598,3417.65869,208.840,
2339.17847,176.598,3417.75024,208.840,
2339.27002,175.598,3417.84180,208.840,
2339.36157,174.598,3417.93335,208.840,
2339.45313,174.598,3418.02490,208.840,
2339.54443,174.598,3418.11646,208.840,
2339.63599,173.598,3418.20801,208.840,
2339.72754,173.598,3418.29932,208.840,
2339.81909,173.598,3418.39087,207.840,
2339.91064,173.598,3418.48242,208.840,
2340.00220,173.598,3418.57397,208.840,
2340.09375,173.598,3418.66553,209.840,
2340.18506,174.598,3418.75708,208.840,
2340.27661,173.598,3418.84863,208.840,
2340.36816,175.598,3418.94019,208.840,
2340.45972,175.598,3419.03149,208.840,
2340.55127,175.598,3419.12305,209.840,
2340.64282,175.598,3419.21460,209.840,
2340.73438,175.598,3419.30615,209.840,
2340.82593,176.598,3419.39771,209.840,
2340.91724,177.598,3419.48926,209.840,
2341.00879,177.598,3419.58081,209.840,
2341.10034,177.598,3419.67212,209.840,
2341.19189,177.598,3419.76367,210.840,
2341.28345,177.598,3419.85522,209.840,
2341.37500,177.598,3419.94678,209.840,
2341.46655,177.598,3420.03833,209.840,
2341.55786,177.598,3420.12988,210.840,
2341.64941,178.598,3420.22144,210.840,
2341.74097,177.598,3420.31299,210.840,
2341.83252,178.598,3420.40430,210.840,
2341.92407,178.598,3420.49585,210.840,
2342.01563,178.598,3420.58740,210.840,
2342.10718,178.598,3420.67896,210.840,
2342.19873,178.598,3420.77051,210.840,
2342.29004,178.598,3420.86206,210.840,
2342.38159,179.598,3420.95361,210.840,
2342.47314,178.598,3421.04492,211.840,
2342.56470,178.598,3421.13647,210.840,
2342.65625,179.598,3421.22803,210.840,
2342.74780,178.598,3421.31958,210.840,
2342.83936,179.598,3421.41113,210.840,
2342.93091,179.598,3421.50269,211.840,
2343.02222,178.598,3421.59424,211.840,
2343.11377,178.598,3421.68579,211.840,
2343.20532,179.598,3421.77710,211.840,
2343.29688,178.598,3421.86865,211.840,
2343.38843,178.598,3421.96021,211.840,
2343.47998,178.598,3422.05176,211.840,
2343.57153,178.598,3422.14331,211.840,
2343.66284,178.598,3422.23486,211.840,
2343.75439,179.598,3422.32642,211.840,
2343.84595,179.598,3422.41797,211.840,
2343.93750,178.598,3422.50928,211.840,
2344.02905,179.598,3422.60083,212.840,
2344.12061,179.598,3422.69238,211.840,
2344.21216,179.598,3422.78394,211.840,
2344.30371,179.598,3422.87549,212.840,
2344.39502,179.598,3422.96704,212.840,
2344.48657,179.598,3423.05859,212.840,
2344.57813,179.598,3423.14990,212.840,
2344.66968,179.598,3423.24146,212.840,
2344.76123,179.598,3423.33301,212.840,
2344.85278,179.598,3423.42456,212.840,
2344.94434,179.598,3423.51611,213.840,
2345.03589,179.598,3423.60767,212.840,
2345.12720,179.598,3423.69922,212.840,
2345.21875,179.598,3423.79077,213.840,
2345.31030,180.598,3423.88208,212.840,
2345.40186,180.598,3423.97363,212.840,
2345.49341,179.598,3424.06519,213.840,
2345.58496,180.598,3424.15674,213.840,
2345.67651,180.598,3424.24829,212.840,
2345.76782,179.598,3424.33984,213.840,
2345.85938,180.598,3424.43140,213.840,
2345.95093,180.598,3424.52295,213.840,
2346.04248,180.598,3424.61426,213.840,
2346.13403,180.598,3424.70581,213.840,
2346.22559,180.598,3424.79736,213.840,
2346.31714,180.598,3424.88892,213.840,
2346.40869,180.598,3424.98047,214.840,
2346.50000,180.598,3425.07202,214.840,
2346.59155,180.598,3425.16357,214.840,
2346.68311,180.598,3425.25488,214.840,
2346.77466,181.598,3425.34644,214.840,
2346.86621,181.598,3425.43799,214.840,
2346.95776,180.598,3425.52954,214.840,
2347.04932,180.598,3425.62109,214.840,
2347.14087,181.598,3425.71265,214.840,
2347.23218,180.598,3425.80420,214.840,
2347.32373,180.598,3425.89575,214.840,
2347.41528,181.598,3425.98706,215.840,
2347.50684,181.598,3426.07861,214.840,
2347.59839,180.598,3426.17017,214.840,
2347.68994,180.598,3426.26172,215.840,
2347.78149,181.598,3426.35327,214.840,
2347.87280,181.598,3426.44482,215.840,
2347.96436,181.598,3426.53638,215.840,
2348.05591,181.598,3426.62769,216.840,
2348.14746,181.598,3426.71924,215.840,
2348.23901,181.598,3426.81079,214.840,
2348.33057,181.598,3426.90234,215.840,
2348.42212,181.598,3426.99390,215.840,
2348.51367,181.598,3427.08545,215.840,
2348.60498,182.598,3427.17700,215.840,
2348.69653,181.598,3427.26855,215.840,
2348.78809,181.598,3427.35986,215.840,
2348.87964,182.598,3427.45142,216.840,
2348.97119,182.598,3427.54297,216.840,
2349.06274,181.598,3427.63452,215.840,
2349.15430,181.598,3427.72607,215.840,
2349.24561,182.598,3427.81763,216.840,
2349.33716,182.598,3427.90918,216.840,
2349.42871,182.598,3428.00073,216.840,
2349.52026,182.598,3428.09204,216.840,
2349.61182,182.598,3428.18359,216.840,
2349.70337,182.598,3428.27515,216.840,
2349.79492,182.598,3428.36670,216.840,
2349.88647,183.598,3428.45825,217.840,
2349.97778,182.598,3428.54980,217.840,
2350.06934,182.598,3428.64136,216.840,
2350.16089,183.598,3428.73267,216.840,
2350.25244,182.598,3428.82422,216.840,
2350.34399,183.598,3428.91577,217.840,
2350.43555,182.598,3429.00732,217.840,
2350.52710,183.598,3429.09888,217.840,
2350.61865,182.598,3429.19043,217.840,
2350.70996,182.598,3429.28198,218.840,
2350.80151,182.598,3429.37354,217.840,
2350.89307,183.598,3429.46484,217.840,
2350.98462,182.598,3429.55640,217.840,
2351.07617,182.598,3429.64795,218.840,
2351.16772,183.598,3429.73950,217.840,
2351.25928,183.598,3429.83105,217.840,
2351.35059,183.598,3429.92261,218.840,
2351.44214,183.598,3430.01416,218.840,
2351.53369,182.598,3430.10571,218.840,
2351.62524,183.598,3430.19702,218.840,
2351.71680,183.598,3430.28857,219.840,
2351.80835,183.598,3430.38013,218.840,
2351.89990,183.598,3430.47168,218.840,
2351.99146,183.598,3430.56323,218.840,
2352.08276,183.598,3430.65479,218.840,
2352.17432,183.598,3430.74634,218.840,
2352.26587,183.598,3430.83765,218.840,
2352.35742,183.598,3430.92920,219.840,
2352.44897,183.598,3431.02075,218.840,
2352.54053,183.598,3431.11230,219.840,
2352.63208,184.598,3431.20386,218.840,
2352.72363,183.598,3431.29541,218.840,
2352.81494,183.598,3431.38696,219.840,
2352.90649,183.598,3431.47852,219.840,
2352.99805,183.598,3431.56982,218.840,
2353.08960,184.598,3431.66138,218.840,
2353.18115,183.598,3431.75293,219.840,
2353.27271,184.598,3431.84448,220.840,
2353.36426,184.598,3431.93604,219.840,
2353.45557,183.598,3432.02759,219.840,
2353.54712,183.598,3432.11914,220.840,
2353.63867,184.598,3432.21069,220.840,
2353.73022,183.598,3432.30200,220.840,
2353.82178,184.598,3432.39355,220.840,
2353.91333,183.598,3432.48511,220.840,
2354.00488,184.598,3432.57666,221.840,
2354.09644,184.598,3432.66821,221.840,
2354.18774,184.598,3432.75977,221.840,
2354.27930,184.598,3432.85132,221.840,
2354.37085,185.598,3432.94263,221.840,
2354.46240,184.598,3433.03418,221.840,
2354.55396,185.598,3433.12573,221.840,
2354.64551,185.598,3433.21729,221.840,
2354.73706,185.598,3433.30884,222.840,
2354.82837,185.598,3433.40039,221.840,
2354.91992,185.598,3433.49194,221.840,
2355.01147,185.598,3433.58350,221.840,
2355.10303,185.598,3433.67480,221.840,
2355.19458,185.598,3433.76636,221.840,
2355.28613,184.598,3433.85791,221.840,
2355.37769,185.598,3433.94946,221.840,
2355.46924,185.598,3434.04102,221.840,
2355.56055,185.598,3434.13257,221.840,
2355.65210,185.598,3434.22412,221.840,
2355.74365,185.598,3434.31543,221.840,
2355.83521,185.598,3434.40698,221.840,
2355.92676,185.598,3434.49854,221.840,
2356.01831,185.598,3434.59009,221.840,
2356.10986,185.598,3434.68164,221.840,
2356.20142,185.598,3434.77319,222.840,
2356.29272,185.598,3434.86475,221.840,
2356.38428,185.598,3434.95630,221.840,
2356.47583,184.598,3435.04761,221.840,
2356.56738,185.598,3435.13916,221.840,
2356.65894,185.598,3435.23071,221.840,
2356.75049,185.598,3435.32227,221.840,
2356.84204,185.598,3435.41382,221.840,
2356.93335,184.598,3435.50537,222.840,
2357.02490,184.598,3435.59692,222.840,
2357.11646,183.598,3435.68848,222.840,
2357.20801,183.598,3435.77979,223.840,
2357.29956,182.598,3435.87134,223.840,
2357.39111,182.598,3435.96289,223.840,
2357.48267,182.598,3436.05444,223.840,
2357.57422,183.598,3436.14600,223.840,
2357.66553,183.598,3436.23755,224.840,
2357.75708,183.598,3436.32910,224.840,
2357.84863,183.598,3436.42041,224.840,
2357.94019,184.598,3436.51196,223.840,
2358.03174,184.598,3436.60352,224.840,
2358.12329,184.598,3436.69507,224.840,
2358.21484,185.598,3436.78662,224.840,
2358.30640,185.598,3436.87817,224.840,
2358.39771,185.598,3436.96973,225.840,
2358.48926,187.598,3437.06128,224.840,
2358.58081,185.598,3437.15259,224.840,
2358.67236,186.598,3437.24414,224.840,
2358.76392,186.598,3437.33569,224.840,
2358.85547,186.598,3437.42725,224.840,
2358.94702,186.598,3437.51880,224.840,
2359.03833,186.598,3437.61035,224.840,
2359.12988,187.598,3437.70190,225.840,
2359.22144,187.598,3437.79346,224.840,
2359.31299,187.598,3437.88477,225.840,
2359.40454,187.598,3437.97632,225.840,
2359.49609,187.598,3438.06787,225.840,
2359.58765,187.598,3438.15942,225.840,
2359.67920,187.598,3438.25098,225.840,
2359.77051,187.598,3438.34253,225.840,
2359.86206,187.598,3438.43408,225.840,
2359.95361,188.598,3438.52539,225.840,
2360.04517,187.598,3438.61694,225.840,
2360.13672,188.598,3438.70850,225.840,
2360.22827,187.598,3438.80005,225.840,
2360.31982,187.598,3438.89160,225.840,
2360.41113,187.598,3438.98315,226.840,
2360.50269,187.598,3439.07471,226.840,
2360.59424,188.598,3439.16626,226.840,
2360.68579,187.598,3439.25757,226.840,
2360.77734,187.598,3439.34912,226.840,
2360.86890,187.598,3439.44067,226.840,
2360.96045,187.598,3439.53223,226.840,
2361.05200,188.598,3439.62378,226.840,
2361.14331,188.598,3439.71533,227.840,
2361.23486,187.598,3439.80688,227.840,
2361.32642,187.598,3439.89819,226.840,
2361.41797,188.598,3439.98975,226.840,
2361.50952,188.598,3440.08130,226.840,
2361.60107,188.598,3440.17285,226.840,
2361.69263,188.598,3440.26440,226.840,
2361.78418,188.598,3440.35596,226.840,
2361.87549,188.598,3440.44751,227.840,
2361.96704,188.598,3440.53906,227.840,
2362.05859,189.598,3440.63037,227.840,
2362.15015,188.598,3440.72192,227.840,
2362.24170,189.598,3440.81348,227.840,
2362.33325,188.598,3440.90503,227.840,
2362.42480,189.598,3440.99658,227.840,
2362.51611,188.598,3441.08813,227.840,
2362.60767,188.598,3441.17969,227.840,
2362.69922,188.598,3441.27124,228.840,
2362.79077,189.598,3441.36255,227.840,
2362.88232,189.598,3441.45410,228.840,
2362.97388,189.598,3441.54565,228.840,
2363.06543,189.598,3441.63721,228.840,
2363.15698,189.598,3441.72876,228.840,
2363.24829,189.598,3441.82031,228.840,
2363.33984,189.598,3441.91187,229.840,
2363.43140,189.598,3442.00317,228.840,
2363.52295,189.598,3442.09473,229.840,
2363.61450,189.598,3442.18628,229.840,
2363.70605,189.598,3442.27783,228.840,
2363.79761,189.598,3442.36938,229.840,
2363.88916,189.598,3442.46094,229.840,
2363.98047,189.598,3442.55249,229.840,
2364.07202,189.598,3442.64404,229.840,
2364.16357,189.598,3442.73535,229.840,
2364.25513,190.598,3442.82690,229.840,
2364.34668,190.598,3442.91846,229.840,
2364.43823,190.598,3443.01001,229.840,
2364.52979,190.598,3443.10156,229.840,
2364.62109,190.598,3443.19312,229.840,
2364.71265,190.598,3443.28467,229.840,
2364.80420,190.598,3443.37622,229.840,
2364.89575,190.598,3443.46753,230.840,
2364.98730,190.598,3443.55908,230.840,
2365.07886,190.598,3443.65063,230.840,
2365.17041,190.598,3443.74219,230.840,
2365.26196,190.598,3443.83374,230.840,
2365.35327,190.598,3443.92529,230.840,
2365.44482,190.598,3444.01685,230.840,
2365.53638,190.598,3444.10815,230.840,
2365.62793,190.598,3444.19971,231.840,
2365.71948,190.598,3444.29126,231.840,
2365.81104,191.598,3444.38281,230.840,
2365.90259,191.598,3444.47437,230.840,
2365.99414,190.598,3444.56592,231.840,
2366.08545,190.598,3444.65747,231.840,
2366.17700,191.598,3444.74902,231.840,
2366.26855,191.598,3444.84033,231.840,
2366.36011,191.598,3444.93188,231.840,
2366.45166,191.598,3445.02344,232.840,
2366.54321,191.598,3445.11499,231.840,
2366.63477,191.598,3445.20654,232.840,
2366.72607,191.598,3445.29810,232.840,
2366.81763,190.598,3445.38965,232.840,
2366.90918,190.598,3445.48096,232.840,
2367.00073,191.598,3445.57251,232.840,
2367.09229,191.598,3445.66406,232.840,
2367.18384,191.598,3445.75562,232.840,
2367.27539,192.598,3445.84717,232.840,
2367.36694,191.598,3445.93872,232.840,
2367.45825,191.598,3446.03027,232.840,
2367.54980,191.598,3446.12183,232.840,
2367.64136,191.598,3446.21313,232.840,
2367.73291,192.598,3446.30469,232.840,
2367.82446,191.598,3446.39624,232.840,
2367.91602,191.598,3446.48779,233.840,
2368.00757,192.598,3446.57935,232.840,
2368.09888,192.598,3446.67090,233.840,
2368.19043,191.598,3446.76245,233.840,
2368.28198,192.598,3446.85400,233.840,
2368.37354,191.598,3446.94531,233.840,
2368.46509,192.598,3447.03687,233.840,
2368.55664,192.598,3447.12842,233.840,
2368.64819,191.598,3447.21997,233.840,
2368.73975,192.598,3447.31152,233.840,
2368.83105,192.598,3447.40308,233.840,
2368.92261,192.598,3447.49463,233.840,
2369.01416,192.598,3447.58594,233.840,
2369.10571,193.598,3447.67749,233.840,
2369.19727,193.598,3447.76904,234.840,
2369.28882,192.598,3447.86060,233.840,
2369.38037,192.598,3447.95215,235.840,
2369.47192,193.598,3448.04370,234.840,
2369.56323,192.598,3448.13525,234.840,
2369.65479,192.598,3448.22681,234.840,
2369.74634,192.598,3448.31812,234.840,
2369.83789,192.598,3448.40967,234.840,
2369.92944,192.598,3448.50122,234.840,
2370.02100,193.598,3448.59277,235.840,
2370.11255,193.598,3448.68433,234.840,
2370.20386,193.598,3448.77588,234.840,
2370.29541,193.598,3448.86743,234.840,
2370.38696,193.598,3448.95898,235.840,
2370.47852,194.598,3449.05029,234.840,
2370.57007,193.598,3449.14185,235.840,
2370.66162,193.598,3449.23340,234.840,
2370.75317,193.598,3449.32495,235.840,
2370.84473,193.598,3449.41650,236.840,
2370.93604,193.598,3449.50806,235.840,
2371.02759,193.598,3449.59961,235.840,
2371.11914,193.598,3449.69092,235.840,
2371.21069,193.598,3449.78247,235.840,
2371.30225,193.598,3449.87402,235.840,
2371.39380,193.598,3449.96558,235.840,
2371.48535,193.598,3450.05713,235.840,
2371.57690,193.598,3450.14868,236.840,
2371.66821,194.598,3450.24023,235.840,
2371.75977,193.598,3450.33179,235.840,
2371.85132,193.598,3450.42310,236.840,
2371.94287,193.598,3450.51465,236.840,
2372.03442,193.598,3450.60620,235.840,
2372.12598,192.598,3450.69775,235.840,
2372.21753,192.598,3450.78931,235.840,
2372.30884,192.598,3450.88086,236.840,
2372.40039,191.598,3450.97241,235.840,
2372.49194,191.598,3451.06372,235.840,
2372.58350,192.598,3451.15527,235.840,
2372.67505,192.598,3451.24683,235.840,
2372.76660,191.598,3451.33838,236.840,
2372.85815,192.598,3451.42993,236.840,
2372.94971,192.598,3451.52148,236.840,
2373.04102,192.598,3451.61304,236.840,
2373.13257,193.598,3451.70459,237.840,
2373.22412,192.598,3451.79590,236.840,
2373.31567,193.598,3451.88745,237.840,
2373.40723,193.598,3451.97900,237.840,
2373.49878,193.598,3452.07056,237.840,
2373.59033,194.598,3452.16211,237.840,
2373.68164,193.598,3452.25366,238.840,
2373.77319,194.598,3452.34521,238.840,
2373.86475,194.598,3452.43677,238.840,
2373.95630,194.598,3452.52808,238.840,
2374.04785,194.598,3452.61963,238.840,
2374.13940,194.598,3452.71118,238.840,
2374.23096,194.598,3452.80273,239.840,
2374.32251,194.598,3452.89429,239.840,
2374.41382,194.598,3452.98584,239.840,
2374.50537,193.598,3453.07739,239.840,
2374.59692,193.598,3453.16870,239.840,
2374.68848,193.598,3453.26025,240.840,
2374.78003,193.598,3453.35181,239.840,
2374.87158,193.598,3453.44336,239.840,
2374.96313,193.598,3453.53491,240.840,
2375.05469,194.598,3453.62646,240.840,
2375.14600,194.598,3453.71802,240.840,
2375.23755,194.598,3453.80957,241.840,
2375.32910,195.598,3453.90088,240.840,
2375.42065,195.598,3453.99243,240.840,
2375.51221,195.598,3454.08398,240.840,
2375.60376,195.598,3454.17554,240.840,
2375.69531,195.598,3454.26709,240.840,
2375.78662,195.598,3454.35864,240.840,
2375.87817,195.598,3454.45020,240.840,
2375.96973,195.598,3454.54175,240.840,
2376.06128,196.598,3454.63306,240.840,
2376.15283,195.598,3454.72461,240.840,
2376.24438,196.598,3454.81616,239.840,
2376.33594,196.598,3454.90771,240.840,
2376.42749,196.598,3454.99927,240.840,
2376.51880,196.598,3455.09082,240.840,
2376.61035,196.598,3455.18237,240.840,
2376.70190,196.598,3455.27368,241.840,
2376.79346,196.598,3455.36523,240.840,
2376.88501,196.598,3455.45679,240.840,
2376.97656,196.598,3455.54834,241.840,
2377.06812,196.598,3455.63989,241.840,
2377.15967,196.598,3455.73145,241.840,
2377.25098,196.598,3455.82300,241.840,
2377.34253,196.598,3455.91455,241.840,
2377.43408,196.598,3456.00586,241.840,
2377.52563,197.598,3456.09741,241.840,
2377.61719,196.598,3456.18896,241.840,
2377.70874,197.598,3456.28052,241.840,
2377.80029,196.598,3456.37207,241.840,
2377.89160,196.598,3456.46362,242.840,
2377.98315,196.598,3456.55518,242.840,
2378.07471,197.598,3456.64673,242.840,
2378.16626,196.598,3456.73804,242.840,
2378.25781,197.598,3456.82959,242.840,
2378.34937,196.598,3456.92114,242.840,
2378.44092,197.598,3457.01270,242.840,
2378.53247,197.598,3457.10425,242.840,
2378.62378,197.598,3457.19580,243.840,
2378.71533,197.598,3457.28735,242.840,
2378.80688,197.598,3457.37866,243.840,
2378.89844,197.598,3457.47021,243.840,
2378.98999,197.598,3457.56177,242.840,
2379.08154,198.598,3457.65332,242.840,
2379.17310,197.598,3457.74487,242.840,
2379.26440,197.598,3457.83643,243.840,
2379.35596,197.598,3457.92798,243.840,
2379.44751,197.598,3458.01953,243.840,
2379.53906,197.598,3458.11084,243.840,
2379.63062,197.598,3458.20239,243.840,
2379.72217,197.598,3458.29395,243.840,
2379.81372,197.598,3458.38550,244.840,
2379.90527,197.598,3458.47705,243.840,
2379.99658,198.598,3458.56860,243.840,
2380.08813,198.598,3458.66016,244.840,
2380.17969,198.598,3458.75146,244.840,
2380.27124,198.598,3458.84302,244.840,
2380.36279,198.598,3458.93457,244.840,
2380.45435,198.598,3459.02612,244.840,
2380.54590,198.598,3459.11768,244.840,
2380.63745,198.598,3459.20923,244.840,
2380.72876,198.598,3459.30078,244.840,
2380.82031,198.598,3459.39233,244.840,
2380.91187,198.598,3459.48364,244.840,
2381.00342,198.598,3459.57520,244.840,
2381.09497,198.598,3459.66675,246.840,
2381.18652,199.598,3459.75830,245.840,
2381.27808,198.598,3459.84985,245.840,
2381.36938,198.598,3459.94141,245.840,
2381.46094,198.598,3460.03296,245.840,
2381.55249,198.598,3460.12451,245.840,
2381.64404,198.598,3460.21582,245.840,
2381.73560,199.598,3460.30737,245.840,
2381.82715,198.598,3460.39893,245.840,
2381.91870,199.598,3460.49048,246.840,
2382.01025,199.598,3460.58203,246.840,
2382.10156,199.598,3460.67358,245.840,
2382.19312,199.598,3460.76514,246.840,
2382.28467,199.598,3460.85645,246.840,
2382.37622,199.598,3460.94800,246.840,
2382.46777,199.598,3461.03955,246.840,
2382.55933,198.598,3461.13110,247.840,
2382.65088,199.598,3461.22266,247.840,
2382.74243,199.598,3461.31421,247.840,
2382.83374,199.598,3461.40576,247.840,
2382.92529,199.598,3461.49731,247.840,
2383.01685,199.598,3461.58862,247.840,
2383.10840,199.598,3461.68018,247.840,
2383.19995,199.598,3461.77173,247.840,
2383.29150,200.598,3461.86328,247.840,
2383.38306,200.598,3461.95483,247.840,
2383.47437,200.598,3462.04639,247.840,
2383.56592,200.598,3462.13794,247.840,
2383.65747,200.598,3462.22949,247.840,
2383.74902,199.598,3462.32080,247.840,
2383.84058,200.598,3462.41235,247.840,
2383.93213,200.598,3462.50391,247.840,
2384.02368,200.598,3462.59546,249.840,
2384.11523,200.598,3462.68701,248.840,
2384.20654,200.598,3462.77856,248.840,
2384.29810,200.598,3462.87012,248.840,
2384.38965,200.598,3462.96143,248.840,
2384.48120,200.598,3463.05298,248.840,
2384.57275,200.598,3463.14453,248.840,
2384.66431,200.598,3463.23608,249.840,
2384.75586,201.598,3463.32764,249.840,
2384.84717,201.598,3463.41919,248.840,
2384.93872,200.598,3463.51074,249.840,
2385.03027,200.598,3463.60229,248.840,
2385.12183,200.598,3463.69360,248.840,
2385.21338,201.598,3463.78516,249.840,
2385.30493,201.598,3463.87671,249.840,
2385.39648,201.598,3463.96826,249.840,
2385.48804,201.598,3464.05981,249.840,
2385.57935,201.598,3464.15137,249.840,
2385.67090,201.598,3464.24292,249.840,
2385.76245,201.598,3464.33423,249.840,
2385.85400,201.598,3464.42578,249.840,
2385.94556,201.598,3464.51733,250.840,
2386.03711,201.598,3464.60889,249.840,
2386.12866,201.598,3464.70044,250.840,
2386.22021,201.598,3464.79199,250.840,
2386.31152,202.598,3464.88354,250.840,
2386.40308,201.598,3464.97510,250.840,
2386.49463,201.598,3465.06641,249.840,
2386.58618,201.598,3465.15796,250.840,
2386.67773,202.598,3465.24951,250.840,
2386.76929,201.598,3465.34106,250.840,
2386.86084,202.598,3465.43262,250.840,
2386.95215,202.598,3465.52417,251.840,
2387.04370,202.598,3465.61572,250.840,
2387.13525,202.598,3465.70728,251.840,
2387.22681,202.598,3465.79858,251.840,
2387.31836,202.598,3465.89014,250.840,
2387.40991,202.598,3465.98169,251.840,
2387.50146,201.598,3466.07324,251.840,
2387.59302,202.598,3466.16479,251.840,
2387.68433,202.598,3466.25635,251.840,
2387.77588,202.598,3466.34790,252.840,
2387.86743,202.598,3466.43921,251.840,
2387.95898,202.598,3466.53076,251.840,
2388.05054,202.598,3466.62231,251.840,
2388.14209,202.598,3466.71387,251.840,
2388.23364,203.598,3466.80542,252.840,
2388.32520,202.598,3466.89697,251.840,
2388.41650,202.598,3466.98853,253.840,
2388.50806,203.598,3467.08008,252.840,
2388.59961,202.598,3467.17139,253.840,
2388.69116,202.598,3467.26294,252.840,
2388.78271,203.598,3467.35449,252.840,
2388.87427,202.598,3467.44604,252.840,
2388.96582,203.598,3467.53760,253.840,
2389.05713,203.598,3467.62915,253.840,
2389.14868,203.598,3467.72070,252.840,
2389.24023,202.598,3467.81226,252.840,
2389.33179,203.598,3467.90356,253.840,
2389.42334,203.598,3467.99512,252.840,
2389.51489,203.598,3468.08667,253.840,
2389.60645,203.598,3468.17822,253.840,
2389.69800,202.598,3468.26978,253.840,
2389.78931,202.598,3468.36133,253.840,
2389.88086,202.598,3468.45288,254.840,
2389.97241,202.598,3468.54419,253.840,
2390.06396,202.598,3468.63574,254.840,
2390.15552,201.598,3468.72729,254.840,
2390.24707,201.598,3468.81885,254.840,
2390.33862,201.598,3468.91040,254.840,
2390.43018,201.598,3469.00195,254.840,
2390.52148,201.598,3469.09351,254.840,
2390.61304,201.598,3469.18506,254.840,
2390.70459,202.598,3469.27637,254.840,
2390.79614,202.598,3469.36792,255.840,
2390.88770,202.598,3469.45947,255.840,
2390.97925,203.598,3469.55103,254.840,
2391.07080,203.598,3469.64258,255.840,
2391.16211,203.598,3469.73413,255.840,
2391.25366,203.598,3469.82568,255.840,
2391.34521,203.598,3469.91699,256.840,
2391.43677,203.598,3470.00854,255.840,
2391.52832,203.598,3470.10010,256.840,
2391.61987,203.598,3470.19165,255.840,
2391.71143,203.598,3470.28320,256.840,
2391.80298,203.598,3470.37476,256.840,
2391.89429,204.598,3470.46631,255.840,
2391.98584,204.598,3470.55786,256.840,
2392.07739,203.598,3470.64917,256.840,
2392.16895,204.598,3470.74072,256.840,
2392.26050,203.598,3470.83228,255.840,
2392.35205,202.598,3470.92383,256.840,
2392.44360,202.598,3471.01538,255.840,
2392.53491,202.598,3471.10693,256.840,
2392.62646,202.598,3471.19849,256.840,
2392.71802,202.598,3471.29004,256.840,
2392.80957,203.598,3471.38135,257.840,
2392.90112,202.598,3471.47290,256.840,
2392.99268,203.598,3471.56445,257.840,
2393.08423,203.598,3471.65601,257.840,
2393.17578,203.598,3471.74756,257.840,
2393.26709,204.598,3471.83911,257.840,
2393.35864,203.598,3471.93066,257.840,
2393.45020,205.598,3472.02197,257.840,
2393.54175,204.598,3472.11353,258.840,
2393.63330,205.598,3472.20508,257.840,
2393.72485,205.598,3472.29663,257.840,
2393.81641,205.598,3472.38818,257.840,
2393.90796,205.598,3472.47974,258.840,
2393.99927,206.598,3472.57129,258.840,
2394.09082,205.598,3472.66284,258.840,
2394.18237,205.598,3472.75415,258.840,
2394.27393,206.598,3472.84570,259.840,
2394.36548,206.598,3472.93726,258.840,
2394.45703,205.598,3473.02881,258.840,
2394.54858,206.598,3473.12036,259.840,
2394.63989,206.598,3473.21191,258.840,
2394.73145,206.598,3473.30347,258.840,
2394.82300,206.598,3473.39502,259.840,
2394.91455,206.598,3473.48633,259.840,
2395.00610,206.598,3473.57788,259.840,
2395.09766,207.598,3473.66943,258.840,
2395.18921,206.598,3473.76099,259.840,
2395.28076,206.598,3473.85254,259.840,
2395.37207,206.598,3473.94409,259.840,
2395.46362,206.598,3474.03564,259.840,
2395.55518,206.598,3474.12695,258.840,
2395.64673,206.598,3474.21851,259.840,
2395.73828,206.598,3474.31006,260.840,
2395.82983,206.598,3474.40161,259.840,
2395.92139,206.598,3474.49316,260.840,
2396.01294,206.598,3474.58472,259.840,
2396.10425,207.598,3474.67627,259.840,
2396.19580,207.598,3474.76782,259.840,
2396.28735,206.598,3474.85913,260.840,
2396.37891,207.598,3474.95068,260.840,
2396.47046,206.598,3475.04224,260.840,
2396.56201,207.598,3475.13379,260.840,
2396.65356,207.598,3475.22534,260.840,
2396.74487,207.598,3475.31689,260.840,
2396.83643,207.598,3475.40845,260.840,
2396.92798,207.598,3475.50000,261.840,
2397.01953,206.598,3475.59131,260.840,
2397.11108,207.598,3475.68286,260.840,
2397.20264,207.598,3475.77441,261.840,
2397.29419,207.598,3475.86597,261.840,
2397.38574,207.598,3475.95752,260.840,
2397.47705,207.598,3476.04907,261.840,
2397.56860,207.598,3476.14063,261.840,
2397.66016,207.598,3476.23193,261.840,
2397.75171,207.598,3476.32349,261.840,
2397.84326,207.598,3476.41504,261.840,
2397.93481,208.598,3476.50659,261.840,
2398.02637,208.598,3476.59814,261.840,
2398.11768,208.598,3476.68970,261.840,
2398.20923,208.598,3476.78125,261.840,
2398.30078,208.598,3476.87280,261.840,
2398.39233,208.598,3476.96411,262.840,
2398.48389,208.598,3477.05566,262.840,
2398.57544,208.598,3477.14722,262.840,
2398.66699,208.598,3477.23877,262.840,
2398.75854,208.598,3477.33032,262.840,
2398.84985,208.598,3477.42188,262.840,
2398.94141,208.598,3477.51343,262.840,
2399.03296,208.598,3477.60474,263.840,
2399.12451,208.598,3477.69629,263.840,
2399.21606,208.598,3477.78784,263.840,
2399.30762,208.598,3477.87939,263.840,
2399.39917,208.598,3477.97095,263.840,
2399.49072,209.598,3478.06250,262.840,
2399.58203,208.598,3478.15405,262.840,
2399.67358,208.598,3478.24561,263.840,
2399.76514,209.598,3478.33691,263.840,
2399.85669,209.598,3478.42847,263.840,
2399.94824,209.598,3478.52002,263.840,
2400.03979,209.598,3478.61157,263.840,
2400.13135,209.598,3478.70313,264.840,
2400.22266,209.598,3478.79468,264.840,
2400.31421,208.598,3478.88623,264.840,
2400.40576,209.598,3478.97778,264.840,
2400.49731,209.598,3479.06909,264.840,
2400.58887,208.598,3479.16064,263.840,
2400.68042,209.598,3479.25220,264.840,
2400.77197,210.598,3479.34375,264.840,
2400.86353,209.598,3479.43530,264.840,
2400.95483,209.598,3479.52686,264.840,
2401.04639,209.598,3479.61841,264.840,
2401.13794,209.598,3479.70972,264.840,
2401.22949,209.598,3479.80127,265.840,
2401.32104,209.598,3479.89282,264.840,
2401.41260,209.598,3479.98438,265.840,
2401.50415,209.598,3480.07593,265.840,
2401.59570,209.598,3480.16748,266.840,
2401.68701,210.598,3480.25903,265.840,
2401.77856,209.598,3480.35059,265.840,
2401.87012,209.598,3480.44189,266.840,
2401.96167,210.598,3480.53345,266.840,
2402.05322,210.598,3480.62500,266.840,
2402.14478,210.598,3480.71655,266.840,
2402.23633,210.598,3480.80811,266.840,
2402.32764,210.598,3480.89966,266.840,
2402.41919,211.598,3480.99121,266.840,
2402.51074,210.598,3481.08276,266.840,
2402.60229,210.598,3481.17407,266.840,
2402.69385,210.598,3481.26563,266.840,
2402.78540,210.598,3481.35718,266.840,
2402.87695,211.598,3481.44873,266.840,
2402.96851,210.598,3481.54028,266.840,
2403.05981,210.598,3481.63184,266.840,
2403.15137,210.598,3481.72339,266.840,
2403.24292,210.598,3481.81470,266.840,
2403.33447,210.598,3481.90625,267.840,
2403.42603,211.598,3481.99780,266.840,
2403.51758,211.598,3482.08936,266.840,
2403.60913,210.598,3482.18091,267.840,
2403.70044,210.598,3482.27246,266.840,
2403.79199,210.598,3482.36401,267.840,
2403.88354,211.598,3482.45557,267.840,
2403.97510,211.598,3482.54688,267.840,
2404.06665,211.598,3482.63843,267.840,
2404.15820,211.598,3482.72998,267.840,
2404.24976,211.598,3482.82153,268.840,
2404.34131,211.598,3482.91309,267.840,
2404.43262,211.598,3483.00464,267.840,
2404.52417,211.598,3483.09619,268.840,
2404.61572,211.598,3483.18750,268.840,
2404.70728,211.598,3483.27905,268.840,
2404.79883,212.598,3483.37061,267.840,
2404.89038,211.598,3483.46216,268.840,
2404.98193,211.598,3483.55371,268.840,
2405.07349,212.598,3483.64526,268.840,
2405.16479,211.598,3483.73682,269.840,
2405.25635,212.598,3483.82837,268.840,
2405.34790,212.598,3483.91968,268.840,
2405.43945,212.598,3484.01123,268.840,
2405.53101,212.598,3484.10278,268.840,
2405.62256,211.598,3484.19434,268.840,
2405.71411,212.598,3484.28589,269.840,
2405.80542,212.598,3484.37744,269.840,
2405.89697,211.598,3484.46899,269.840,
2405.98853,212.598,3484.56055,270.840,
2406.08008,212.598,3484.65186,270.840,
2406.17163,212.598,3484.74341,269.840,
2406.26318,212.598,3484.83496,269.840,
2406.35474,212.598,3484.92651,269.840,
2406.44629,212.598,3485.01807,269.840,
2406.53760,213.598,3485.10962,270.840,
2406.62915,212.598,3485.20117,269.840,
2406.72070,212.598,3485.29248,269.840,
2406.81226,212.598,3485.38403,269.840,
2406.90381,212.598,3485.47559,270.840,
2406.99536,212.598,3485.56714,270.840,
2407.08691,213.598,3485.65869,270.840,
2407.17847,213.598,3485.75024,270.840,
2407.26978,213.598,3485.84180,270.840,
2407.36133,213.598,3485.93335,270.840,
2407.45288,213.598,3486.02466,271.840,
2407.54443,213.598,3486.11621,270.840,
2407.63599,213.598,3486.20776,271.840,
2407.72754,213.598,3486.29932,271.840,
2407.81909,213.598,3486.39087,271.840,
2407.91040,213.598,3486.48242,271.840,
2408.00195,213.598,3486.57397,271.840,
2408.09351,213.598,3486.66553,271.840,
2408.18506,213.598,3486.75684,271.840,
2408.27661,214.598,3486.84839,271.840,
2408.36816,213.598,3486.93994,271.840,
2408.45972,213.598,3487.03149,271.840,
2408.55127,213.598,3487.12305,271.840,
2408.64258,213.598,3487.21460,271.840,
2408.73413,213.598,3487.30615,272.840,
2408.82568,214.598,3487.39746,272.840,
2408.91724,214.598,3487.48901,273.840,
2409.00879,214.598,3487.58057,272.840,
2409.10034,214.598,3487.67212,273.840,
2409.19189,213.598,3487.76367,273.840,
2409.28345,214.598,3487.85522,273.840,
2409.37476,214.598,3487.94678,273.840,
2409.46631,213.598,3488.03833,273.840,
2409.55786,212.598,3488.12964,273.840,
2409.64941,211.598,3488.22119,273.840,
2409.74097,211.598,3488.31274,273.840,
2409.83252,210.598,3488.40430,273.840,
2409.92407,209.598,3488.49585,273.840,
2410.01538,209.598,3488.58740,273.840,
2410.10693,209.598,3488.67896,273.840,
2410.19849,209.598,3488.77026,273.840,
2410.29004,209.598,3488.86182,273.840,
2410.38159,209.598,3488.95337,273.840,
2410.47314,210.598,3489.04492,273.840,
2410.56470,210.598,3489.13647,273.840,
2410.65625,210.598,3489.22803,273.840,
2410.74756,211.598,3489.31958,272.840,
2410.83911,211.598,3489.41113,273.840,
2410.93066,211.598,3489.50244,273.840,
2411.02222,211.598,3489.59399,273.840,
2411.11377,212.598,3489.68555,273.840,
2411.20532,213.598,3489.77710,273.840,
2411.29688,213.598,3489.86865,274.840,
2411.38818,213.598,3489.96021,274.840,
2411.47974,214.598,3490.05176,274.840,
2411.57129,214.598,3490.14331,274.840,
2411.66284,214.598,3490.23462,274.840,
2411.75439,215.598,3490.32617,274.840,
2411.84595,215.598,3490.41772,275.840,
2411.93750,214.598,3490.50928,275.840,
2412.02905,215.598,3490.60083,275.840,
2412.12036,215.598,3490.69238,275.840,
2412.21191,215.598,3490.78394,275.840,
2412.30347,215.598,3490.87524,276.840,
2412.39502,215.598,3490.96680,276.840,
2412.48657,215.598,3491.05835,276.840,
2412.57813,215.598,3491.14990,276.840,
2412.66968,216.598,3491.24146,276.840,
2412.76123,216.598,3491.33301,276.840,
2412.85254,215.598,3491.42456,276.840,
2412.94409,215.598,3491.51611,276.840,
2413.03564,216.598,3491.60742,276.840,
2413.12720,216.598,3491.69897,276.840,
2413.21875,216.598,3491.79053,276.840,
2413.31030,216.598,3491.88208,277.840,
2413.40186,216.598,3491.97363,277.840,
2413.49316,216.598,3492.06519,277.840,
2413.58472,216.598,3492.15674,276.840,
2413.67627,215.598,3492.24829,277.840,
2413.76782,216.598,3492.33960,277.840,
2413.85938,216.598,3492.43115,277.840,
2413.95093,216.598,3492.52271,277.840,
2414.04248,216.598,3492.61426,277.840,
2414.13403,217.598,3492.70581,277.840,
2414.22534,216.598,3492.79736,277.840,
2414.31689,216.598,3492.88892,277.840,
2414.40845,216.598,3492.98022,277.840,
2414.50000,216.598,3493.07178,277.840,
2414.59155,217.598,3493.16333,278.840,
2414.68311,217.598,3493.25488,278.840,
2414.77466,217.598,3493.34644,278.840,
2414.86621,217.598,3493.43799,278.840,
2414.95752,216.598,3493.52954,278.840,
2415.04907,216.598,3493.62109,278.840,
2415.14063,217.598,3493.71240,278.840,
2415.23218,216.598,3493.80396,278.840,
2415.32373,217.598,3493.89551,278.840,
2415.41528,217.598,3493.98706,278.840,
2415.50684,217.598,3494.07861,278.840,
2415.59814,217.598,3494.17017,279.840,
2415.68970,217.598,3494.26172,279.840,
2415.78125,217.598,3494.35327,279.840,
2415.87280,217.598,3494.44458,279.840,
2415.96436,217.598,3494.53613,279.840,
2416.05591,217.598,3494.62769,278.840,
2416.14746,217.598,3494.71924,279.840,
2416.23901,217.598,3494.81079,279.840,
2416.33032,217.598,3494.90234,279.840,
2416.42188,218.598,3494.99390,280.840,
2416.51343,217.598,3495.08521,280.840,
2416.60498,217.598,3495.17676,279.840,
2416.69653,218.598,3495.26831,280.840,
2416.78809,217.598,3495.35986,280.840,
2416.87964,217.598,3495.45142,279.840,
2416.97095,218.598,3495.54297,280.840,
2417.06250,218.598,3495.63452,280.840,
2417.15405,218.598,3495.72607,280.840,
2417.24561,218.598,3495.81738,280.840,
2417.33716,218.598,3495.90894,280.840,
2417.42871,218.598,3496.00049,280.840,
2417.52026,218.598,3496.09204,280.840,
2417.61182,218.598,3496.18359,280.840,
2417.70313,218.598,3496.27515,281.840,
2417.79468,218.598,3496.36670,280.840,
2417.88623,219.598,3496.45801,280.840,
2417.97778,219.598,3496.54956,281.840,
2418.06934,218.598,3496.64111,281.840,
2418.16089,219.598,3496.73267,281.840,
2418.25244,219.598,3496.82422,281.840,
2418.34399,219.598,3496.91577,281.840,
2418.43530,218.598,3497.00732,281.840,
2418.52686,219.598,3497.09888,281.840,
2418.61841,219.598,3497.19019,281.840,
2418.70996,219.598,3497.28174,281.840,
2418.80151,219.598,3497.37329,281.840,
2418.89307,219.598,3497.46484,281.840,
2418.98462,219.598,3497.55640,282.840,
2419.07593,219.598,3497.64795,282.840,
2419.16748,219.598,3497.73950,282.840,
2419.25903,219.598,3497.83105,282.840,
2419.35059,219.598,3497.92236,282.840,
2419.44214,219.598,3498.01392,282.840,
2419.53369,219.598,3498.10547,282.840,
2419.62524,219.598,3498.19702,282.840,
2419.71680,219.598,3498.28857,282.840,
2419.80811,219.598,3498.38013,283.840,
2419.89966,219.598,3498.47168,283.840,
2419.99121,220.598,3498.56299,283.840,
2420.08276,219.598,3498.65454,283.840,
2420.17432,219.598,3498.74609,283.840,
2420.26587,219.598,3498.83765,283.840,
2420.35742,220.598,3498.92920,283.840,
2420.44897,219.598,3499.02075,283.840,
2420.54028,219.598,3499.11230,283.840,
2420.63184,220.598,3499.20386,283.840,
2420.72339,220.598,3499.29517,283.840,
2420.81494,220.598,3499.38672,284.840,
2420.90649,219.598,3499.47827,284.840,
2420.99805,220.598,3499.56982,283.840,
2421.08960,220.598,3499.66138,284.840,
2421.18091,220.598,3499.75293,284.840,
2421.27246,220.598,3499.84448,284.840,
2421.36401,220.598,3499.93604,284.840,
2421.45557,221.598,3500.02734,284.840,
2421.54712,221.598,3500.11890,284.840,
2421.63867,221.598,3500.21045,284.840,
2421.73022,220.598,3500.30200,284.840,
2421.82178,220.598,3500.39355,284.840,
2421.91309,221.598,3500.48511,284.840,
2422.00464,220.598,3500.57666,285.840,
2422.09619,221.598,3500.66797,286.840,
2422.18774,221.598,3500.75952,285.840,
2422.27930,221.598,3500.85107,285.840,
2422.37085,221.598,3500.94263,285.840,
2422.46240,221.598,3501.03418,285.840,
2422.55371,221.598,3501.12573,286.840,
2422.64526,221.598,3501.21729,285.840,
2422.73682,221.598,3501.30884,286.840,
2422.82837,221.598,3501.40015,285.840,
2422.91992,222.598,3501.49170,286.840,
2423.01147,221.598,3501.58325,286.840,
2423.10303,221.598,3501.67480,285.840,
2423.19458,222.598,3501.76636,286.840,
2423.28589,222.598,3501.85791,286.840,
2423.37744,222.598,3501.94946,286.840,
2423.46899,222.598,3502.04077,287.840,
2423.56055,222.598,3502.13232,287.840,
2423.65210,222.598,3502.22388,287.840,
2423.74365,222.598,3502.31543,287.840,
2423.83521,222.598,3502.40698,287.840,
2423.92676,222.598,3502.49854,287.840,
2424.01807,222.598,3502.59009,287.840,
2424.10962,223.598,3502.68164,287.840,
2424.20117,222.598,3502.77295,287.840,
2424.29272,222.598,3502.86450,287.840,
2424.38428,223.598,3502.95605,287.840,
2424.47583,222.598,3503.04761,288.840,
2424.56738,223.598,3503.13916,287.840,
2424.65869,222.598,3503.23071,288.840,
2424.75024,222.598,3503.32227,288.840,
2424.84180,223.598,3503.41382,288.840,
2424.93335,222.598,3503.50513,288.840,
2425.02490,223.598,3503.59668,289.840,
2425.11646,223.598,3503.68823,288.840,
2425.20801,223.598,3503.77979,288.840,
2425.29956,223.598,3503.87134,288.840,
2425.39087,223.598,3503.96289,288.840,
2425.48242,223.598,3504.05444,288.840,
2425.57397,223.598,3504.14575,288.840,
2425.66553,223.598,3504.23730,289.840,
2425.75708,223.598,3504.32886,289.840,
2425.84863,224.598,3504.42041,288.840,
2425.94019,223.598,3504.51196,289.840,
2426.03174,223.598,3504.60352,289.840,
2426.12305,223.598,3504.69507,288.840,
2426.21460,223.598,3504.78662,289.840,
2426.30615,223.598,3504.87793,289.840,
2426.39771,223.598,3504.96948,289.840,
2426.48926,223.598,3505.06104,289.840,
2426.58081,223.598,3505.15259,289.840,
2426.67236,223.598,3505.24414,289.840,
2426.76367,223.598,3505.33569,289.840,
2426.85522,224.598,3505.42725,289.840,
2426.94678,223.598,3505.51880,289.840,
2427.03833,224.598,3505.61011,290.840,
2427.12988,223.598,3505.70166,290.840,
2427.22144,223.598,3505.79321,290.840,
2427.31299,224.598,3505.88477,290.840,
2427.40454,224.598,3505.97632,290.840,
2427.49585,224.598,3506.06787,290.840,
2427.58740,223.598,3506.15942,291.840,
2427.67896,223.598,3506.25073,290.840,
2427.77051,222.598,3506.34229,290.840,
2427.86206,222.598,3506.43384,291.840,
2427.95361,222.598,3506.52539,291.840,
2428.04517,222.598,3506.61694,291.840,
2428.13672,222.598,3506.70850,291.840,
2428.22803,222.598,3506.80005,290.840,
2428.31958,222.598,3506.89160,291.840,
2428.41113,222.598,3506.98291,291.840,
2428.50269,223.598,3507.07446,291.840,
2428.59424,223.598,3507.16602,291.840,
2428.68579,224.598,3507.25757,291.840,
2428.77734,224.598,3507.34912,291.840,
2428.86865,224.598,3507.44067,291.840,
2428.96021,225.598,3507.53223,291.840,
2429.05176,225.598,3507.62354,291.840,
2429.14331,224.598,3507.71509,291.840,
2429.23486,225.598,3507.80664,291.840,
2429.32642,225.598,3507.89819,291.840,
2429.41797,225.598,3507.98975,291.840,
2429.50952,225.598,3508.08130,291.840,
2429.60083,226.598,3508.17285,291.840,
2429.69238,225.598,3508.26440,292.840,
2429.78394,226.598,3508.35571,292.840,
2429.87549,226.598,3508.44727,292.840,
2429.96704,226.598,3508.53882,292.840,
2430.05859,226.598,3508.63037,293.840,
2430.15015,226.598,3508.72192,293.840,
2430.24146,226.598,3508.81348,293.840,
2430.33301,226.598,3508.90503,293.840,
2430.42456,226.598,3508.99658,293.840,
2430.51611,226.598,3509.08789,293.840,
2430.60767,226.598,3509.17944,293.840,
2430.69922,226.598,3509.27100,293.840,
2430.79077,226.598,3509.36255,294.840,
2430.88232,226.598,3509.45410,295.840,
2430.97363,226.598,3509.54565,294.840,
2431.06519,226.598,3509.63721,294.840,
2431.15674,226.598,3509.72852,295.840,
2431.24829,226.598,3509.82007,294.840,
2431.33984,227.598,3509.91162,294.840,
2431.43140,227.598,3510.00317,295.840,
2431.52295,226.598,3510.09473,295.840,
2431.61450,227.598,3510.18628,295.840,
2431.70581,227.598,3510.27783,294.840,
2431.79736,227.598,3510.36938,295.840,
2431.88892,227.598,3510.46069,295.840,
2431.98047,227.598,3510.55225,295.840,
2432.07202,227.598,3510.64380,295.840,
2432.16357,226.598,3510.73535,295.840,
2432.25513,227.598,3510.82690,295.840,
2432.34644,227.598,3510.91846,296.840,
2432.43799,227.598,3511.01001,296.840,
2432.52954,226.598,3511.10156,296.840,
2432.62109,227.598,3511.19287,296.840,
2432.71265,227.598,3511.28442,296.840,
2432.80420,227.598,3511.37598,296.840,
2432.89575,227.598,3511.46753,296.840,
2432.98730,227.598,3511.55908,296.840,
2433.07861,227.598,3511.65063,296.840,
2433.17017,228.598,3511.74219,296.840,
2433.26172,227.598,3511.83350,296.840,
2433.35327,227.598,3511.92505,296.840,
2433.44482,227.598,3512.01660,296.840,
2433.53638,228.598,3512.10815,297.840,
2433.62793,228.598,3512.19971,297.840,
2433.71948,227.598,3512.29126,297.840,
2433.81079,228.598,3512.38281,297.840,
2433.90234,228.598,3512.47437,297.840,
2433.99390,228.598,3512.56567,297.840,
2434.08545,228.598,3512.65723,297.840,
2434.17700,228.598,3512.74878,297.840,
2434.26855,228.598,3512.84033,298.840,
2434.36011,228.598,3512.93188,297.840,
2434.45142,229.598,3513.02344,298.840,
2434.54297,228.598,3513.11499,298.840,
2434.63452,229.598,3513.20654,297.840,
2434.72607,229.598,3513.29785,297.840,
2434.81763,229.598,3513.38940,298.840,
2434.90918,228.598,3513.48096,297.840,
2435.00073,229.598,3513.57251,298.840,
2435.09229,229.598,3513.66406,298.840,
2435.18359,228.598,3513.75562,298.840,
2435.27515,229.598,3513.84717,299.840,
2435.36670,229.598,3513.93848,298.840,
2435.45825,229.598,3514.03003,299.840,
2435.54980,229.598,3514.12158,298.840,
2435.64136,229.598,3514.21313,298.840,
2435.73291,229.598,3514.30469,299.840,
2435.82422,229.598,3514.39624,299.840,
2435.91577,229.598,3514.48779,299.840,
2436.00732,229.598,3514.57935,299.840,
2436.09888,230.598,3514.67065,299.840,
2436.19043,229.598,3514.76221,299.840,
2436.28198,230.598,3514.85376,299.840,
2436.37354,229.598,3514.94531,299.840,
2436.46509,230.598,3515.03687,299.840,
2436.55640,230.598,3515.12842,300.840,
2436.64795,230.598,3515.21997,300.840,
2436.73950,229.598,3515.31128,300.840,
2436.83105,230.598,3515.40283,299.840,
2436.92261,230.598,3515.49438,300.840,
2437.01416,229.598,3515.58594,300.840,
2437.10571,230.598,3515.67749,300.840,
2437.19727,230.598,3515.76904,300.840,
2437.28857,230.598,3515.86060,300.840,
2437.38013,229.598,3515.95215,300.840,
2437.47168,230.598,3516.04346,300.840,
2437.56323,230.598,3516.13501,301.840,
2437.65479,230.598,3516.22656,301.840,
2437.74634,231.598,3516.31812,301.840,
2437.83789,230.598,3516.40967,301.840,
2437.92920,230.598,3516.50122,301.840,
2438.02075,230.598,3516.59277,301.840,
2438.11230,231.598,3516.68433,301.840,
2438.20386,231.598,3516.77563,301.840,
2438.29541,230.598,3516.86719,301.840,
2438.38696,231.598,3516.95874,301.840,
2438.47852,230.598,3517.05029,302.840,
2438.57007,230.598,3517.14185,302.840,
2438.66138,231.598,3517.23340,302.840,
2438.75293,230.598,3517.32495,302.840,
2438.84448,231.598,3517.41626,302.840,
2438.93604,231.598,3517.50781,302.840,
2439.02759,232.598,3517.59937,302.840,
2439.11914,231.598,3517.69092,303.840,
2439.21069,231.598,3517.78247,302.840,
2439.30225,231.598,3517.87402,303.840,
2439.39355,232.598,3517.96558,303.840,
2439.48511,231.598,3518.05713,302.840,
2439.57666,232.598,3518.14844,302.840,
2439.66821,232.598,3518.23999,303.840,
2439.75977,232.598,3518.33154,303.840,
2439.85132,231.598,3518.42310,303.840,
2439.94287,231.598,3518.51465,303.840,
2440.03418,232.598,3518.60620,303.840,
2440.12573,232.598,3518.69775,303.840,
2440.21729,232.598,3518.78931,303.840,
2440.30884,232.598,3518.88062,303.840,
2440.40039,232.598,3518.97217,303.840,
2440.49194,233.598,3519.06372,304.840,
2440.58350,233.598,3519.15527,304.840,
2440.67505,232.598,3519.24683,304.840,
2440.76636,232.598,3519.33838,303.840,
2440.85791,233.598,3519.42993,303.840,
2440.94946,233.598,3519.52124,304.840,
2441.04102,232.598,3519.61279,304.840,
2441.13257,233.598,3519.70435,304.840,
2441.22412,232.598,3519.79590,304.840,
2441.31567,232.598,3519.88745,304.840,
2441.40698,232.598,3519.97900,304.840,
2441.49854,233.598,3520.07056,305.840,
2441.59009,233.598,3520.16211,305.840,
2441.68164,233.598,3520.25342,305.840,
2441.77319,233.598,3520.34497,304.840,
2441.86475,233.598,3520.43652,305.840,
2441.95630,233.598,3520.52808,305.840,
2442.04785,233.598,3520.61963,305.840,
2442.13916,234.598,3520.71118,305.840,
2442.23071,232.598,3520.80273,306.840,
2442.32227,233.598,3520.89404,305.840,
2442.41382,234.598,3520.98560,306.840,
2442.50537,233.598,3521.07715,306.840,
2442.59692,233.598,3521.16870,307.840,
2442.68848,233.598,3521.26025,306.840,
2442.78003,233.598,3521.35181,306.840,
2442.87134,233.598,3521.44336,306.840,
2442.96289,234.598,3521.53491,306.840,
2443.05444,234.598,3521.62622,306.840,
2443.14600,234.598,3521.71777,306.840,
2443.23755,234.598,3521.80933,306.840,
2443.32910,235.598,3521.90088,307.840,
2443.42065,235.598,3521.99243,307.840,
2443.51196,235.598,3522.08398,306.840,
2443.60352,235.598,3522.17554,307.840,
2443.69507,235.598,3522.26709,307.840,
2443.78662,235.598,3522.35840,307.840,
2443.87817,235.598,3522.44995,307.840,
2443.96973,235.598,3522.54150,307.840,
2444.06128,235.598,3522.63306,308.840,
2444.15283,235.598,3522.72461,307.840,
2444.24414,235.598,3522.81616,307.840,
2444.33569,234.598,3522.90771,308.840,
2444.42725,235.598,3522.99902,308.840,
2444.51880,235.598,3523.09058,308.840,
2444.61035,235.598,3523.18213,308.840,
2444.70190,234.598,3523.27368,308.840,
2444.79346,234.598,3523.36523,309.840,
2444.88501,235.598,3523.45679,308.840,
2444.97632,235.598,3523.54834,308.840,
2445.06787,235.598,3523.63989,308.840,
2445.15942,235.598,3523.73120,309.840,
2445.25098,235.598,3523.82275,309.840,
2445.34253,235.598,3523.91431,309.840,
2445.43408,235.598,3524.00586,310.840,
2445.52563,235.598,3524.09741,310.840,
2445.61694,234.598,3524.18896,310.840,
2445.70850,234.598,3524.28052,310.840,
2445.80005,233.598,3524.37207,310.840,
2445.89160,233.598,3524.46338,311.840,
2445.98315,232.598,3524.55493,310.840,
2446.07471,232.598,3524.64648,310.840,
2446.16626,231.598,3524.73804,311.840,
2446.25781,231.598,3524.82959,310.840,
2446.34912,233.598,3524.92114,310.840,
2446.44067,232.598,3525.01270,310.840,
2446.53223,232.598,3525.10400,310.840,
2446.62378,233.598,3525.19556,311.840,
2446.71533,233.598,3525.28711,310.840,
2446.80688,233.598,3525.37866,311.840,
2446.89844,234.598,3525.47021,310.840,
2446.98999,235.598,3525.56177,311.840,
2447.08130,234.598,3525.65332,311.840,
2447.17285,235.598,3525.74487,310.840,
2447.26440,235.598,3525.83618,311.840,
2447.35596,235.598,3525.92773,311.840,
2447.44751,235.598,3526.01929,310.840,
2447.53906,236.598,3526.11084,311.840,
2447.63062,236.598,3526.20239,311.840,
2447.72192,236.598,3526.29395,311.840,
2447.81348,237.598,3526.38550,310.840,
2447.90503,236.598,3526.47681,311.840,
2447.99658,237.598,3526.56836,311.840,
2448.08813,237.598,3526.65991,311.840,
2448.17969,237.598,3526.75146,311.840,
2448.27124,237.598,3526.84302,312.840,
2448.36279,237.598,3526.93457,312.840,
2448.45410,237.598,3527.02612,313.840,
2448.54565,237.598,3527.11768,313.840,
2448.63721,236.598,3527.20898,313.840,
2448.72876,237.598,3527.30054,313.840,
2448.82031,237.598,3527.39209,313.840,
2448.91187,237.598,3527.48364,313.840,
2449.00342,237.598,3527.57520,313.840,
2449.09473,237.598,3527.66675,313.840,
2449.18628,237.598,3527.75830,313.840,
2449.27783,238.598,3527.84985,314.840,
2449.36938,238.598,3527.94116,314.840,
2449.46094,238.598,3528.03271,313.840,
2449.55249,237.598,3528.12427,314.840,
2449.64404,237.598,3528.21582,314.840,
2449.73560,238.598,3528.30737,313.840,
2449.82690,237.598,3528.39893,314.840,
2449.91846,238.598,3528.49048,314.840,
2450.01001,238.598,3528.58179,314.840,
2450.10156,238.598,3528.67334,313.840,
2450.19312,238.598,3528.76489,314.840,
2450.28467,238.598,3528.85645,314.840,
2450.37622,238.598,3528.94800,314.840,
2450.46777,238.598,3529.03955,314.840,
2450.55908,238.598,3529.13110,314.840,
2450.65063,239.598,3529.22266,315.840,
2450.74219,239.598,3529.31396,315.840,
2450.83374,238.598,3529.40552,314.840,
2450.92529,239.598,3529.49707,314.840,
2451.01685,239.598,3529.58862,315.840,
2451.10840,238.598,3529.68018,315.840,
2451.19971,239.598,3529.77173,315.840,
2451.29126,239.598,3529.86328,315.840,
2451.38281,239.598,3529.95483,316.840,
2451.47437,239.598,3530.04614,316.840,
2451.56592,239.598,3530.13770,315.840,
2451.65747,239.598,3530.22925,316.840,
2451.74902,238.598,3530.32080,317.840,
2451.84058,238.598,3530.41235,316.840,
2451.93188,239.598,3530.50391,316.840,
2452.02344,239.598,3530.59546,316.840,
2452.11499,239.598,3530.68677,316.840,
2452.20654,239.598,3530.77832,317.840,
2452.29810,239.598,3530.86987,317.840,
2452.38965,238.598,3530.96143,317.840,
2452.48120,239.598,3531.05298,316.840,
2452.57275,239.598,3531.14453,317.840,
2452.66406,239.598,3531.23608,317.840,
2452.75562,239.598,3531.32764,317.840,
2452.84717,239.598,3531.41895,317.840,
2452.93872,240.598,3531.51050,317.840,
2453.03027,239.598,3531.60205,317.840,
2453.12183,239.598,3531.69360,317.840,
2453.21338,239.598,3531.78516,317.840,
2453.30469,240.598,3531.87671,317.840,
2453.39624,240.598,3531.96826,317.840,
2453.48779,240.598,3532.05957,317.840,
2453.57935,240.598,3532.15112,317.840,
2453.67090,241.598,3532.24268,318.840,
2453.76245,240.598,3532.33423,318.840,
2453.85400,240.598,3532.42578,317.840,
2453.94556,240.598,3532.51733,317.840,
2454.03687,240.598,3532.60889,318.840,
2454.12842,240.598,3532.70044,318.840,
2454.21997,241.598,3532.79175,317.840,
2454.31152,241.598,3532.88330,319.840,
2454.40308,240.598,3532.97485,318.840,
2454.49463,240.598,3533.06641,319.840,
2454.58618,240.598,3533.15796,318.840,
2454.67749,241.598,3533.24951,319.840,
2454.76904,241.598,3533.34106,319.840,
2454.86060,240.598,3533.43262,319.840,
2454.95215,241.598,3533.52393,319.840,
2455.04370,241.598,3533.61548,320.840,
2455.13525,241.598,3533.70703,319.840,
2455.22681,241.598,3533.79858,319.840,
2455.31836,241.598,3533.89014,319.840,
2455.40967,241.598,3533.98169,320.840,
2455.50122,242.598,3534.07324,319.840,
2455.59277,241.598,3534.16455,320.840,
2455.68433,241.598,3534.25610,320.840,
2455.77588,242.598,3534.34766,321.840,
2455.86743,241.598,3534.43921,321.840,
2455.95898,242.598,3534.53076,321.840,
2456.05054,241.598,3534.62231,320.840,
2456.14185,242.598,3534.71387,321.840,
2456.23340,242.598,3534.80542,321.840,
2456.32495,242.598,3534.89673,321.840,
2456.41650,242.598,3534.98828,321.840,
2456.50806,242.598,3535.07983,321.840,
2456.59961,243.598,3535.17139,321.840,
2456.69116,242.598,3535.26294,321.840,
2456.78247,242.598,3535.35449,321.840,
2456.87402,242.598,3535.44604,321.840,
2456.96558,242.598,3535.53760,321.840,
2457.05713,242.598,3535.62891,321.840,
2457.14868,242.598,3535.72046,321.840,
2457.24023,242.598,3535.81201,322.840,
2457.33179,242.598,3535.90356,322.840,
2457.42334,243.598,3535.99512,322.840,
2457.51465,242.598,3536.08667,322.840,
2457.60620,242.598,3536.17822,322.840,
2457.69775,242.598,3536.26953,322.840,
2457.78931,243.598,3536.36108,322.840,
2457.88086,243.598,3536.45264,322.840,
2457.97241,242.598,3536.54419,322.840,
2458.06396,243.598,3536.63574,323.840,
2458.15552,242.598,3536.72729,322.840,
2458.24683,243.598,3536.81885,322.840,
2458.33838,243.598,3536.91040,323.840,
2458.42993,243.598,3537.00171,323.840,
2458.52148,243.598,3537.09326,323.840,
2458.61304,243.598,3537.18481,323.840,
2458.70459,243.598,3537.27637,324.840,
2458.79614,242.598,3537.36792,323.840,
2458.88745,243.598,3537.45947,324.840,
2458.97900,243.598,3537.55103,323.840,
2459.07056,243.598,3537.64258,323.840,
2459.16211,243.598,3537.73389,324.840,
2459.25366,244.598,3537.82544,324.840,
2459.34521,244.598,3537.91699,324.840,
2459.43677,243.598,3538.00854,324.840,
2459.52832,244.598,3538.10010,324.840,
2459.61963,244.598,3538.19165,324.840,
2459.71118,244.598,3538.28320,324.840,
2459.80273,244.598,3538.37451,324.840,
2459.89429,244.598,3538.46606,324.840,
2459.98584,243.598,3538.55762,324.840,
2460.07739,244.598,3538.64917,324.840,
2460.16895,244.598,3538.74072,325.840,
2460.26025,244.598,3538.83228,325.840,
2460.35181,244.598,3538.92383,325.840,
2460.44336,244.598,3539.01538,325.840,
2460.53491,244.598,3539.10669,325.840,
2460.62646,244.598,3539.19824,325.840,
2460.71802,244.598,3539.28979,325.840,
2460.80957,244.598,3539.38135,326.840,
2460.90112,244.598,3539.47290,325.840,
2460.99243,245.598,3539.56445,325.840,
2461.08398,245.598,3539.65601,326.840,
2461.17554,245.598,3539.74731,326.840,
2461.26709,244.598,3539.83887,325.840,
2461.35864,245.598,3539.93042,326.840,
2461.45020,245.598,3540.02197,326.840,
2461.54175,245.598,3540.11353,326.840,
2461.63330,245.598,3540.20508,327.840,
2461.72461,245.598,3540.29663,327.840,
2461.81616,245.598,3540.38818,326.840,
2461.90771,246.598,3540.47949,327.840,
2461.99927,245.598,3540.57104,327.840,
2462.09082,245.598,3540.66260,327.840,
2462.18237,245.598,3540.75415,327.840,
2462.27393,246.598,3540.84570,327.840,
2462.36523,245.598,3540.93726,327.840,
2462.45679,246.598,3541.02881,327.840,
2462.54834,246.598,3541.12036,328.840,
2462.63989,246.598,3541.21167,327.840,
2462.73145,246.598,3541.30322,328.840,
2462.82300,246.598,3541.39478,328.840,
2462.91455,246.598,3541.48633,328.840,
2463.00610,246.598,3541.57788,328.840,
2463.09741,246.598,3541.66943,329.840,
2463.18896,246.598,3541.76099,328.840,
2463.28052,246.598,3541.85229,328.840,
2463.37207,246.598,3541.94385,328.840,
2463.46362,246.598,3542.03540,329.840,
2463.55518,247.598,3542.12695,328.840,
2463.64673,247.598,3542.21851,329.840,
2463.73828,247.598,3542.31006,328.840,
2463.82959,248.598,3542.40161,329.840,
2463.92114,249.598,3542.49316,329.840,
2464.01270,249.598,3542.58447,329.840,
2464.10425,250.598,3542.67603,329.840,
2464.19580,250.598,3542.76758,330.840,
2464.28735,251.598,3542.85913,329.840,
2464.37891,250.598,3542.95068,329.840,
2464.47021,251.598,3543.04224,330.840,
2464.56177,251.598,3543.13379,331.840,
2464.65332,251.598,3543.22534,329.840,
2464.74487,251.598,3543.31665,330.840,
2464.83643,251.598,3543.40820,330.840,
2464.92798,250.598,3543.49976,330.840,
2465.01953,250.598,3543.59131,330.840,
2465.11108,250.598,3543.68286,331.840,
2465.20239,249.598,3543.77441,330.840,
2465.29395,249.598,3543.86597,330.840,
2465.38550,250.598,3543.95728,331.840,
2465.47705,249.598,3544.04883,330.840,
2465.56860,249.598,3544.14038,331.840,
2465.66016,248.598,3544.23193,331.840,
2465.75171,249.598,3544.32349,331.840,
2465.84326,248.598,3544.41504,332.840,
2465.93457,248.598,3544.50659,332.840,
2466.02612,248.598,3544.59814,332.840,
2466.11768,248.598,3544.68945,332.840,
2466.20923,248.598,3544.78101,332.840,
2466.30078,248.598,3544.87256,332.840,
2466.39233,247.598,3544.96411,332.840,
2466.48389,248.598,3545.05566,331.840,
2466.57520,248.598,3545.14722,332.840,
2466.66675,248.598,3545.23877,332.840,
2466.75830,248.598,3545.33008,332.840,
2466.84985,249.598,3545.42163,332.840,
2466.94141,249.598,3545.51318,332.840,
2467.03296,249.598,3545.60474,332.840,
2467.12451,249.598,3545.69629,332.840,
2467.21606,249.598,3545.78784,332.840,
2467.30737,248.598,3545.87939,332.840,
2467.39893,249.598,3545.97095,333.840,
2467.49048,249.598,3546.06226,334.840,
2467.58203,249.598,3546.15381,333.840,
2467.67358,249.598,3546.24536,333.840,
2467.76514,249.598,3546.33691,334.840,
2467.85669,249.598,3546.42847,334.840,
2467.94800,249.598,3546.52002,334.840,
2468.03955,249.598,3546.61157,334.840,
2468.13110,249.598,3546.70313,334.840,
2468.22266,249.598,3546.79443,334.840,
2468.31421,250.598,3546.88599,334.840,
2468.40576,250.598,3546.97754,334.840,
2468.49731,249.598,3547.06909,334.840,
2468.58887,249.598,3547.16064,334.840,
2468.68018,249.598,3547.25220,334.840,
2468.77173,249.598,3547.34375,335.840,
2468.86328,249.598,3547.43506,334.840,
2468.95483,250.598,3547.52661,335.840,
2469.04639,249.598,3547.61816,335.840,
2469.13794,249.598,3547.70972,335.840,
2469.22949,249.598,3547.80127,335.840,
2469.32104,250.598,3547.89282,335.840,
2469.41235,250.598,3547.98438,335.840,
2469.50391,250.598,3548.07593,335.840,
2469.59546,250.598,3548.16724,336.840,
2469.68701,250.598,3548.25879,335.840,
2469.77856,251.598,3548.35034,335.840,
2469.87012,250.598,3548.44189,336.840,
2469.96167,251.598,3548.53345,335.840,
2470.05298,250.598,3548.62500,336.840,
2470.14453,251.598,3548.71655,336.840,
2470.23608,251.598,3548.80811,336.840,
2470.32764,251.598,3548.89941,337.840,
2470.41919,251.598,3548.99097,337.840,
2470.51074,251.598,3549.08252,337.840,
2470.60229,251.598,3549.17407,337.840,
2470.69385,250.598,3549.26563,337.840,
2470.78516,250.598,3549.35718,336.840,
2470.87671,251.598,3549.44873,337.840,
2470.96826,251.598,3549.54004,337.840,
2471.05981,251.598,3549.63159,337.840,
2471.15137,251.598,3549.72314,337.840,
2471.24292,252.598,3549.81470,337.840,
2471.33447,251.598,3549.90625,337.840,
2471.42603,251.598,3549.99780,337.840,
2471.51733,251.598,3550.08936,338.840,
2471.60889,251.598,3550.18091,338.840,
2471.70044,251.598,3550.27222,338.840,
2471.79199,252.598,3550.36377,338.840,
2471.88354,252.598,3550.45532,338.840,
2471.97510,251.598,3550.54688,338.840,
2472.06665,252.598,3550.63843,338.840,
2472.15796,252.598,3550.72998,338.840,
2472.24951,252.598,3550.82153,338.840,
2472.34106,251.598,3550.91284,338.840,
2472.43262,252.598,3551.00439,339.840,
2472.52417,252.598,3551.09595,338.840,
2472.61572,252.598,3551.18750,339.840,
2472.70728,253.598,3551.27905,339.840,
2472.79883,252.598,3551.37061,339.840,
2472.89014,252.598,3551.46216,339.840,
2472.98169,253.598,3551.55371,340.840,
2473.07324,253.598,3551.64502,339.840,
2473.16479,253.598,3551.73657,339.840,
2473.25635,253.598,3551.82813,339.840,
2473.34790,253.598,3551.91968,340.840,
2473.43945,253.598,3552.01123,339.840,
2473.53076,253.598,3552.10278,340.840,
2473.62231,253.598,3552.19434,340.840,
2473.71387,252.598,3552.28589,340.840,
2473.80542,253.598,3552.37720,340.840,
2473.89697,253.598,3552.46875,340.840,
2473.98853,253.598,3552.56030,340.840,
2474.08008,253.598,3552.65186,340.840,
2474.17163,253.598,3552.74341,340.840,
2474.26294,253.598,3552.83496,340.840,
2474.35449,253.598,3552.92651,341.840,
2474.44604,253.598,3553.01782,341.840,
2474.53760,254.598,3553.10938,342.840,
2474.62915,253.598,3553.20093,341.840,
2474.72070,253.598,3553.29248,341.840,
2474.81226,253.598,3553.38403,342.840,
2474.90381,254.598,3553.47559,342.840,
2474.99512,254.598,3553.56714,341.840,
2475.08667,254.598,3553.65869,342.840,
2475.17822,254.598,3553.75000,342.840,
2475.26978,254.598,3553.84155,342.840,
2475.36133,254.598,3553.93311,342.840,
2475.45288,254.598,3554.02466,342.840,
2475.54443,254.598,3554.11621,342.840,
2475.63574,254.598,3554.20776,342.840,
2475.72729,255.598,3554.29932,343.840,
2475.81885,254.598,3554.39087,343.840,
2475.91040,254.598,3554.48218,343.840,
2476.00195,255.598,3554.57373,343.840,
2476.09351,255.598,3554.66528,343.840,
2476.18506,254.598,3554.75684,343.840,
2476.27661,254.598,3554.84839,344.840,
2476.36792,255.598,3554.93994,343.840,
2476.45947,255.598,3555.03149,343.840,
2476.55103,255.598,3555.12280,344.840,
2476.64258,255.598,3555.21436,344.840,
2476.73413,255.598,3555.30591,344.840,
2476.82568,255.598,3555.39746,343.840,
2476.91724,255.598,3555.48901,344.840,
2477.00879,255.598,3555.58057,344.840,
2477.10010,255.598,3555.67212,344.840,
2477.19165,255.598,3555.76367,344.840,
2477.28320,256.598,3555.85498,345.840,
2477.37476,255.598,3555.94653,344.840,
2477.46631,255.598,3556.03809,344.840,
2477.55786,255.598,3556.12964,345.840,
2477.64941,255.598,3556.22119,345.840,
2477.74072,256.598,3556.31274,345.840,
2477.83228,256.598,3556.40430,345.840,
2477.92383,255.598,3556.49585,345.840,
2478.01538,256.598,3556.58716,345.840,
2478.10693,256.598,3556.67871,345.840,
2478.19849,256.598,3556.77026,345.840,
2478.29004,256.598,3556.86182,346.840,
2478.38159,256.598,3556.95337,345.840,
2478.47290,256.598,3557.04492,346.840,
2478.56445,257.598,3557.13647,346.840,
2478.65601,257.598,3557.22778,346.840,
2478.74756,257.598,3557.31934,346.840,
2478.83911,256.598,3557.41089,346.840,
2478.93066,257.598,3557.50244,346.840,
2479.02222,257.598,3557.59399,346.840,
2479.11353,257.598,3557.68555,347.840,
2479.20508,257.598,3557.77710,347.840,
2479.29663,257.598,3557.86865,346.840,
2479.38818,257.598,3557.95996,347.840,
2479.47974,257.598,3558.05151,347.840,
2479.57129,256.598,3558.14307,347.840,
2479.66284,257.598,3558.23462,347.840,
2479.75439,257.598,3558.32617,348.840,
2479.84570,258.598,3558.41772,348.840,
2479.93726,258.598,3558.50928,348.840,
2480.02881,259.598,3558.60059,348.840,
2480.12036,259.598,3558.69214,348.840,
2480.21191,260.598,3558.78369,348.840,
2480.30347,260.598,3558.87524,348.840,
2480.39502,260.598,3558.96680,349.840,
2480.48657,260.598,3559.05835,349.840,
2480.57788,260.598,3559.14990,349.840,
2480.66943,261.598,3559.24146,349.840,
2480.76099,261.598,3559.33276,349.840,
2480.85254,260.598,3559.42432,349.840,
2480.94409,260.598,3559.51587,349.840,
2481.03564,261.598,3559.60742,349.840,
2481.12720,260.598,3559.69897,349.840,
2481.21851,260.598,3559.79053,349.840,
2481.31006,260.598,3559.88208,350.840,
2481.40161,259.598,3559.97363,350.840,
2481.49316,260.598,3560.06494,349.840,
2481.58472,260.598,3560.15649,350.840,
2481.67627,259.598,3560.24805,350.840,
2481.76782,259.598,3560.33960,350.840,
2481.85938,259.598,3560.43115,349.840,
2481.95068,258.598,3560.52271,350.840,
2482.04224,259.598,3560.61426,350.840,
2482.13379,260.598,3560.70557,351.840,
2482.22534,259.598,3560.79712,351.840,
2482.31689,259.598,3560.88867,350.840,
2482.40845,260.598,3560.98022,351.840,
2482.50000,261.598,3561.07178,351.840,
2482.59155,262.598,3561.16333,350.840,
2482.68286,263.598,3561.25488,351.840,
2482.77441,263.598,3561.34644,351.840,
2482.86597,263.598,3561.43774,351.840,
2482.95752,264.598,3561.52930,351.840,
2483.04907,263.598,3561.62085,352.840,
2483.14063,263.598,3561.71240,352.840,
2483.23218,262.598,3561.80396,351.840,
2483.32349,262.598,3561.89551,351.840,
2483.41504,262.598,3561.98706,351.840,
2483.50659,261.598,3562.07861,351.840,
2483.59814,262.598,3562.16992,352.840,
2483.68970,262.598,3562.26147,351.840,
2483.78125,260.598,3562.35303,351.840,
2483.87280,261.598,3562.44458,352.840,
2483.96436,260.598,3562.53613,352.840,
2484.05566,260.598,3562.62769,352.840,
2484.14722,260.598,3562.71924,352.840,
2484.23877,261.598,3562.81055,353.840,
2484.33032,260.598,3562.90210,353.840,
2484.42188,261.598,3562.99365,353.840,
2484.51343,260.598,3563.08521,353.840,
2484.60498,261.598,3563.17676,353.840,
2484.69629,260.598,3563.26831,354.840,
2484.78784,261.598,3563.35986,353.840,
2484.87939,261.598,3563.45142,354.840,
2484.97095,261.598,3563.54272,354.840,
2485.06250,261.598,3563.63428,354.840,
2485.15405,261.598,3563.72583,354.840,
2485.24561,261.598,3563.81738,354.840,
2485.33716,261.598,3563.90894,354.840,
2485.42847,261.598,3564.00049,354.840,
2485.52002,261.598,3564.09204,354.840,
2485.61157,261.598,3564.18335,354.840,
2485.70313,261.598,3564.27490,354.840,
2485.79468,261.598,3564.36646,354.840,
2485.88623,262.598,3564.45801,355.840,
2485.97778,261.598,3564.54956,354.840,
2486.06934,261.598,3564.64111,354.840,
2486.16064,261.598,3564.73267,355.840,
2486.25220,261.598,3564.82422,355.840,
2486.34375,262.598,3564.91553,355.840,
2486.43530,262.598,3565.00708,355.840,
2486.52686,262.598,3565.09863,356.840,
2486.61841,262.598,3565.19019,356.840,
2486.70996,262.598,3565.28174,356.840,
2486.80127,262.598,3565.37329,356.840,
2486.89282,262.598,3565.46484,356.840,
2486.98438,262.598,3565.55640,356.840,
2487.07593,263.598,3565.64771,356.840,
2487.16748,262.598,3565.73926,356.840,
2487.25903,262.598,3565.83081,356.840,
2487.35059,264.598,3565.92236,356.840,
2487.44214,262.598,3566.01392,357.840,
2487.53345,262.598,3566.10547,356.840,
2487.62500,263.598,3566.19702,357.840,
2487.71655,263.598,3566.28833,358.840,
2487.80811,263.598,3566.37988,357.840,
2487.89966,263.598,3566.47144,357.840,
2487.99121,263.598,3566.56299,358.840,
2488.08276,263.598,3566.65454,358.840,
2488.17432,263.598,3566.74609,358.840,
2488.26563,263.598,3566.83765,358.840,
2488.35718,263.598,3566.92920,358.840,
2488.44873,263.598,3567.02051,358.840,
2488.54028,263.598,3567.11206,358.840,
2488.63184,263.598,3567.20361,358.840,
2488.72339,263.598,3567.29517,359.840,
2488.81494,264.598,3567.38672,358.840,
2488.90625,264.598,3567.47827,358.840,
2488.99780,264.598,3567.56982,358.840,
2489.08936,264.598,3567.66138,359.840,
2489.18091,264.598,3567.75269,359.840,
2489.27246,264.598,3567.84424,359.840,
2489.36401,264.598,3567.93579,359.840,
2489.45557,265.598,3568.02734,359.840,
2489.54712,264.598,3568.11890,359.840,
2489.63843,264.598,3568.21045,359.840,
2489.72998,264.598,3568.30200,360.840,
2489.82153,264.598,3568.39331,360.840,
2489.91309,264.598,3568.48486,360.840,
2490.00464,264.598,3568.57642,360.840,
2490.09619,265.598,3568.66797,360.840,
2490.18774,264.598,3568.75952,360.840,
2490.27930,265.598,3568.85107,360.840,
2490.37061,264.598,3568.94263,361.840,
2490.46216,265.598,3569.03418,361.840,
2490.55371,265.598,3569.12549,361.840,
2490.64526,265.598,3569.21704,361.840,
2490.73682,265.598,3569.30859,361.840,
2490.82837,265.598,3569.40015,361.840,
2490.91992,265.598,3569.49170,362.840,
2491.01123,265.598,3569.58325,361.840,
2491.10278,265.598,3569.67480,361.840,
2491.19434,265.598,3569.76611,361.840,
2491.28589,265.598,3569.85767,362.840,
2491.37744,265.598,3569.94922,362.840,
2491.46899,265.598,3570.04077,361.840,
2491.56055,265.598,3570.13232,362.840,
2491.65210,266.598,3570.22388,362.840,
2491.74341,266.598,3570.31543,362.840,
2491.83496,265.598,3570.40698,361.840,
2491.92651,266.598,3570.49829,362.840,
2492.01807,266.598,3570.58984,363.840,
2492.10962,266.598,3570.68140,362.840,
2492.20117,266.598,3570.77295,362.840,
2492.29272,265.598,3570.86450,363.840,
2492.38403,266.598,3570.95605,364.840,
2492.47559,266.598,3571.04761,363.840,
2492.56714,266.598,3571.13916,363.840,
2492.65869,266.598,3571.23047,364.840,
2492.75024,266.598,3571.32202,364.840,
2492.84180,267.598,3571.41357,364.840,
2492.93335,266.598,3571.50513,364.840,
2493.02490,266.598,3571.59668,364.840,
2493.11621,267.598,3571.68823,364.840,
2493.20776,267.598,3571.77979,364.840,
2493.29932,267.598,3571.87109,364.840,
2493.39087,267.598,3571.96265,364.840,
2493.48242,267.598,3572.05420,365.840,
2493.57397,267.598,3572.14575,365.840,
2493.66553,267.598,3572.23730,364.840,
2493.75708,267.598,3572.32886,365.840,
2493.84839,267.598,3572.42041,366.840,
2493.93994,267.598,3572.51196,365.840,
2494.03149,267.598,3572.60327,365.840,
2494.12305,267.598,3572.69482,366.840,
2494.21460,267.598,3572.78638,365.840,
2494.30615,267.598,3572.87793,366.840,
2494.39771,267.598,3572.96948,366.840,
2494.48901,267.598,3573.06104,365.840,
2494.58057,268.598,3573.15259,366.840,
2494.67212,268.598,3573.24414,366.840,
2494.76367,268.598,3573.33545,366.840,
2494.85522,268.598,3573.42700,366.840,
2494.94678,268.598,3573.51855,366.840,
2495.03833,268.598,3573.61011,367.840,
2495.12988,268.598,3573.70166,366.840,
2495.22119,268.598,3573.79321,366.840,
2495.31274,269.598,3573.88477,367.840,
2495.40430,268.598,3573.97607,366.840,
2495.49585,268.598,3574.06763,367.840,
2495.58740,269.598,3574.15918,367.840,
2495.67896,268.598,3574.25073,367.840,
2495.77051,269.598,3574.34229,368.840,
2495.86206,269.598,3574.43384,368.840,
2495.95337,269.598,3574.52539,368.840,
2496.04492,269.598,3574.61694,368.840,
2496.13647,269.598,3574.70825,368.840,
2496.22803,269.598,3574.79980,368.840,
2496.31958,269.598,3574.89136,368.840,
2496.41113,268.598,3574.98291,369.840,
2496.50269,269.598,3575.07446,368.840,
2496.59399,270.598,3575.16602,369.840,
2496.68555,269.598,3575.25757,368.840,
2496.77710,269.598,3575.34912,370.840,
2496.86865,269.598,3575.44043,369.840,
2496.96021,269.598,3575.53198,369.840,
2497.05176,269.598,3575.62354,369.840,
2497.14331,269.598,3575.71509,369.840,
2497.23486,269.598,3575.80664,369.840,
2497.32617,269.598,3575.89819,369.840,
2497.41772,269.598,3575.98975,370.840,
2497.50928,269.598,3576.08105,369.840,
2497.60083,270.598,3576.17261,369.840,
2497.69238,270.598,3576.26416,370.840,
2497.78394,270.598,3576.35571,370.840,
2497.87549,270.598,3576.44727,370.840,
2497.96680,270.598,3576.53882,370.840,
2498.05835,270.598,3576.63037,370.840,
2498.14990,270.598,3576.72192,370.840,
2498.24146,271.598,3576.81323,371.840,
2498.33301,271.598,3576.90479,371.840,
2498.42456,271.598,3576.99634,371.840,
2498.51611,271.598,3577.08789,371.840,
2498.60767,271.598,3577.17944,371.840,
2498.69897,271.598,3577.27100,371.840,
2498.79053,271.598,3577.36255,371.840,
2498.88208,271.598,3577.45386,371.840,
2498.97363,271.598,3577.54541,371.840,
2499.06519,271.598,3577.63696,371.840,
2499.15674,271.598,3577.72852,371.840,
2499.24829,271.598,3577.82007,371.840,
2499.33984,271.598,3577.91162,371.840,
2499.43115,271.598,3578.00317,371.840,
2499.52271,271.598,3578.09473,372.840,
2499.61426,271.598,3578.18604,372.840,
2499.70581,271.598,3578.27759,372.840,
2499.79736,271.598,3578.36914,372.840,
2499.88892,271.598,3578.46069,372.840,
2499.98047,271.598,3578.55225,373.840,
2500.07178,271.598,3578.64380,372.840,
2500.16333,271.598,3578.73535,373.840,
2500.25488,271.598,3578.82690,373.840,
2500.34644,272.598,3578.91821,373.840,
2500.43799,272.598,3579.00977,373.840,
2500.52954,272.598,3579.10132,373.840,
2500.62109,271.598,3579.19287,373.840,
2500.71265,272.598,3579.28442,373.840,
2500.80396,272.598,3579.37598,373.840,
2500.89551,272.598,3579.46753,374.840,
2500.98706,272.598,3579.55884,373.840,
2501.07861,273.598,3579.65039,373.840,
2501.17017,273.598,3579.74194,374.840,
2501.26172,273.598,3579.83350,373.840,
2501.35327,273.598,3579.92505,373.840,
2501.44482,273.598,3580.01660,373.840,
2501.53613,272.598,3580.10815,374.840,
2501.62769,273.598,3580.19971,374.840,
2501.71924,272.598,3580.29102,374.840,
2501.81079,272.598,3580.38257,374.840,
2501.90234,272.598,3580.47412,374.840,
2501.99390,273.598,3580.56567,375.840,
2502.08545,272.598,3580.65723,375.840,
2502.17676,272.598,3580.74878,375.840,
2502.26831,273.598,3580.84033,376.840,
2502.35986,273.598,3580.93188,376.840,
2502.45142,273.598,3581.02319,376.840,
2502.54297,273.598,3581.11475,376.840,
2502.63452,273.598,3581.20630,377.840,
2502.72607,273.598,3581.29785,376.840,
2502.81763,273.598,3581.38940,376.840,
2502.90894,273.598,3581.48096,377.840,
2503.00049,273.598,3581.57251,377.840,
2503.09204,274.598,3581.66382,376.840,
2503.18359,273.598,3581.75537,377.840,
2503.27515,274.598,3581.84692,377.840,
2503.36670,273.598,3581.93848,377.840,
2503.45825,274.598,3582.03003,377.840,
2503.54956,274.598,3582.12158,377.840,
2503.64111,274.598,3582.21313,377.840,
2503.73267,274.598,3582.30469,377.840,
2503.82422,274.598,3582.39600,377.840,
2503.91577,274.598,3582.48755,378.840,
2504.00732,274.598,3582.57910,377.840,
2504.09888,275.598,3582.67065,378.840,
2504.19043,275.598,3582.76221,378.840,
2504.28174,275.598,3582.85376,378.840,
2504.37329,275.598,3582.94531,378.840,
2504.46484,275.598,3583.03662,378.840,
2504.55640,275.598,3583.12817,378.840,
2504.64795,275.598,3583.21973,379.840,
2504.73950,275.598,3583.31128,379.840,
2504.83105,275.598,3583.40283,379.840,
2504.92261,275.598,3583.49438,379.840,
2505.01392,275.598,3583.58594,380.840,
2505.10547,275.598,3583.67749,379.840,
2505.19702,275.598,3583.76880,379.840,
2505.28857,275.598,3583.86035,379.840,
2505.38013,276.598,3583.95190,380.840,
2505.47168,276.598,3584.04346,379.840,
2505.56323,276.598,3584.13501,380.840,
2505.65454,276.598,3584.22656,380.840,
2505.74609,275.598,3584.31812,380.840,
2505.83765,276.598,3584.40967,380.840,
2505.92920,276.598,3584.50098,381.840,
2506.02075,276.598,3584.59253,381.840,
2506.11230,276.598,3584.68408,381.840,
2506.20386,276.598,3584.77563,381.840,
2506.29541,276.598,3584.86719,381.840,
2506.38672,277.598,3584.95874,381.840,
2506.47827,276.598,3585.05029,381.840,
2506.56982,277.598,3585.14160,381.840,
2506.66138,276.598,3585.23315,381.840,
2506.75293,276.598,3585.32471,382.840,
2506.84448,277.598,3585.41626,381.840,
2506.93604,277.598,3585.50781,382.840,
2507.02759,277.598,3585.59937,382.840,
2507.11890,277.598,3585.69092,382.840,
2507.21045,277.598,3585.78247,382.840,
2507.30200,277.598,3585.87378,382.840,
2507.39355,277.598,3585.96533,382.840,
2507.48511,277.598,3586.05688,382.840,
2507.57666,277.598,3586.14844,383.840,
2507.66821,277.598,3586.23999,382.840,
2507.75952,277.598,3586.33154,383.840,
2507.85107,278.598,3586.42310,382.840,
2507.94263,277.598,3586.51465,383.840,
2508.03418,277.598,3586.60596,383.840,
2508.12573,278.598,3586.69751,383.840,
2508.21729,277.598,3586.78906,383.840,
2508.30884,277.598,3586.88062,383.840,
2508.40039,278.598,3586.97217,383.840,
2508.49170,278.598,3587.06372,384.840,
2508.58325,278.598,3587.15527,384.840,
2508.67480,278.598,3587.24658,384.840,
2508.76636,278.598,3587.33813,384.840,
2508.85791,278.598,3587.42969,384.840,
2508.94946,278.598,3587.52124,384.840,
2509.04102,278.598,3587.61279,384.840,
2509.13257,278.598,3587.70435,385.840,
2509.22388,278.598,3587.79590,384.840,
2509.31543,279.598,3587.88745,385.840,
2509.40698,279.598,3587.97876,384.840,
2509.49854,279.598,3588.07031,384.840,
2509.59009,279.598,3588.16187,384.840,
2509.68164,279.598,3588.25342,385.840,
2509.77319,279.598,3588.34497,385.840,
2509.86450,279.598,3588.43652,385.840,
2509.95605,279.598,3588.52808,386.840,
2510.04761,279.598,3588.61938,386.840,
2510.13916,279.598,3588.71094,386.840,
2510.23071,279.598,3588.80249,386.840,
2510.32227,279.598,3588.89404,386.840,
2510.41382,279.598,3588.98560,386.840,
2510.50537,279.598,3589.07715,386.840,
2510.59668,279.598,3589.16870,387.840,
2510.68823,280.598,3589.26025,386.840,
2510.77979,280.598,3589.35156,387.840,
2510.87134,280.598,3589.44312,387.840,
2510.96289,280.598,3589.53467,387.840,
2511.05444,280.598,3589.62622,386.840,
2511.14600,280.598,3589.71777,387.840,
2511.23730,280.598,3589.80933,387.840,
2511.32886,280.598,3589.90088,387.840,
2511.42041,280.598,3589.99243,388.840,
2511.51196,280.598,3590.08374,388.840,
2511.60352,280.598,3590.17529,388.840,
2511.69507,280.598,3590.26685,388.840,
2511.78662,280.598,3590.35840,388.840,
2511.87817,280.598,3590.44995,388.840,
2511.96948,281.598,3590.54150,388.840,
2512.06104,280.598,3590.63306,389.840,
2512.15259,281.598,3590.72437,388.840,
2512.24414,281.598,3590.81592,388.840,
2512.33569,281.598,3590.90747,388.840,
2512.42725,280.598,3590.99902,389.840,
2512.51880,281.598,3591.09058,389.840,
2512.61035,281.598,3591.18213,388.840,
2512.70166,282.598,3591.27368,389.840,
2512.79321,281.598,3591.36523,389.840,
2512.88477,281.598,3591.45654,389.840,
2512.97632,281.598,3591.54810,389.840,
2513.06787,281.598,3591.63965,389.840,
2513.15942,281.598,3591.73120,389.840,
2513.25098,282.598,3591.82275,389.840,
2513.34229,281.598,3591.91431,390.840,
2513.43384,281.598,3592.00586,390.840,
2513.52539,282.598,3592.09741,390.840,
2513.61694,282.598,3592.18872,390.840,
2513.70850,282.598,3592.28027,390.840,
2513.80005,281.598,3592.37183,390.840,
2513.89160,282.598,3592.46338,391.840,
2513.98315,282.598,3592.55493,390.840,
2514.07446,282.598,3592.64648,391.840,
2514.16602,282.598,3592.73804,390.840,
2514.25757,283.598,3592.82935,391.840,
2514.34912,282.598,3592.92090,391.840,
2514.44067,282.598,3593.01245,391.840,
2514.53223,282.598,3593.10400,391.840,
2514.62378,282.598,3593.19556,391.840,
2514.71533,282.598,3593.28711,391.840,
2514.80664,283.598,3593.37866,391.840,
2514.89819,283.598,3593.47021,392.840,
2514.98975,282.598,3593.56152,391.840,
2515.08130,283.598,3593.65308,392.840,
2515.17285,284.598,3593.74463,392.840,
2515.26440,283.598,3593.83618,392.840,
2515.35596,283.598,3593.92773,392.840,
2515.44727,283.598,3594.01929,393.840,
2515.53882,283.598,3594.11084,392.840,
2515.63037,283.598,3594.20239,392.840,
2515.72192,284.598,3594.29370,393.840,
2515.81348,283.598,3594.38525,393.840,
2515.90503,283.598,3594.47681,393.840,
2515.99658,283.598,3594.56836,393.840,
2516.08813,283.598,3594.65991,393.840,
2516.17944,283.598,3594.75146,394.840,
2516.27100,283.598,3594.84302,393.840,
2516.36255,283.598,3594.93433,394.840,
2516.45410,283.598,3595.02588,394.840,
2516.54565,284.598,3595.11743,394.840,
2516.63721,284.598,3595.20898,394.840,
2516.72876,284.598,3595.30054,394.840,
2516.82007,284.598,3595.39209,395.840,
2516.91162,284.598,3595.48364,395.840,
2517.00317,284.598,3595.57520,395.840,
2517.09473,284.598,3595.66650,395.840,
2517.18628,284.598,3595.75806,395.840,
2517.27783,285.598,3595.84961,395.840,
2517.36938,285.598,3595.94116,396.840,
2517.46094,285.598,3596.03271,395.840,
2517.55225,285.598,3596.12427,396.840,
2517.64380,286.598,3596.21582,396.840,
2517.73535,286.598,3596.30713,396.840,
2517.82690,287.598,3596.39868,396.840,
2517.91846,287.598,3596.49023,397.840,
2518.01001,286.598,3596.58179,397.840,
2518.10156,287.598,3596.67334,396.840,
2518.19312,287.598,3596.76489,397.840,
2518.28442,286.598,3596.85645,397.840,
2518.37598,287.598,3596.94800,397.840,
2518.46753,287.598,3597.03931,397.840,
2518.55908,287.598,3597.13086,397.840,
2518.65063,286.598,3597.22241,397.840,
2518.74219,286.598,3597.31396,397.840,
2518.83374,287.598,3597.40552,397.840,
2518.92505,286.598,3597.49707,397.840,
2519.01660,286.598,3597.58862,397.840,
2519.10815,286.598,3597.68018,397.840,
2519.19971,286.598,3597.77148,398.840,
2519.29126,286.598,3597.86304,397.840,
2519.38281,286.598,3597.95459,398.840,
2519.47437,286.598,3598.04614,398.840,
2519.56592,287.598,3598.13770,398.840,
2519.65723,287.598,3598.22925,398.840,
2519.74878,288.598,3598.32080,397.840,
2519.84033,288.598,3598.41211,398.840,
2519.93188,288.598,3598.50366,398.840,
2520.02344,289.598,3598.59521,397.840,
2520.11499,290.598,3598.68677,398.840,
2520.20654,290.598,3598.77832,398.840,
2520.29810,290.598,3598.86987,398.840,
2520.38940,290.598,3598.96143,398.840,
2520.48096,289.598,3599.05298,397.840,
2520.57251,290.598,3599.14429,398.840,
2520.66406,289.598,3599.23584,398.840,
2520.75562,289.598,3599.32739,398.840,
2520.84717,289.598,3599.41895,398.840,
2520.93872,289.598,3599.51050,399.840,
2521.03003,290.598,3599.60205,399.840,
2521.12158,289.598,3599.69360,399.840,
2521.21313,289.598,3599.78516,399.840,
2521.30469,289.598,3599.87646,400.840,
2521.39624,288.598,3599.96802,400.840,
2521.48779,288.598,3600.05957,400.840,
2521.57935,289.598,3600.15112,401.840,
2521.67090,288.598,3600.24268,401.840,
2521.76221,288.598,3600.33423,401.840,
2521.85376,288.598,3600.42578,401.840,
2521.94531,289.598,3600.51709,401.840,
2522.03687,288.598,3600.60864,401.840,
2522.12842,288.598,3600.70020,401.840,
2522.21997,288.598,3600.79175,401.840,
2522.31152,288.598,3600.88330,401.840,
2522.40283,288.598,3600.97485,402.840,
2522.49438,289.598,3601.06641,402.840,
2522.58594,288.598,3601.15796,402.840,
2522.67749,288.598,3601.24927,401.840,
2522.76904,289.598,3601.34082,402.840,
2522.86060,289.598,3601.43237,402.840,
2522.95215,288.598,3601.52393,402.840,
2523.04370,289.598,3601.61548,402.840,
2523.13501,289.598,3601.70703,403.840,
2523.22656,289.598,3601.79858,402.840,
2523.31812,289.598,3601.88989,403.840,
2523.40967,289.598,3601.98145,403.840,
2523.50122,289.598,3602.07300,403.840,
2523.59277,289.598,3602.16455,403.840,
2523.68433,289.598,3602.25610,403.840,
2523.77588,289.598,3602.34766,403.840,
2523.86719,289.598,3602.43921,403.840,
2523.95874,289.598,3602.53076,404.840,
2524.05029,289.598,3602.62207,403.840,
2524.14185,289.598,3602.71362,404.840,
2524.23340,289.598,3602.80518,404.840,
2524.32495,289.598,3602.89673,404.840,
2524.41650,289.598,3602.98828,404.840,
2524.50781,290.598,3603.07983,404.840,
2524.59937,289.598,3603.17139,405.840,
2524.69092,290.598,3603.26294,404.840,
2524.78247,289.598,3603.35425,404.840,
2524.87402,289.598,3603.44580,404.840,
2524.96558,290.598,3603.53735,405.840,
2525.05713,290.598,3603.62891,405.840,
2525.14868,290.598,3603.72046,405.840,
2525.23999,290.598,3603.81201,405.840,
2525.33154,290.598,3603.90356,405.840,
2525.42310,291.598,3603.99487,404.840,
2525.51465,290.598,3604.08643,405.840,
2525.60620,291.598,3604.17798,405.840,
2525.69775,290.598,3604.26953,406.840,
2525.78931,290.598,3604.36108,406.840,
2525.88086,291.598,3604.45264,406.840,
2525.97217,291.598,3604.54419,406.840,
2526.06372,291.598,3604.63574,407.840,
2526.15527,291.598,3604.72705,406.840,
2526.24683,291.598,3604.81860,407.840,
2526.33838,291.598,3604.91016,407.840,
2526.42993,291.598,3605.00171,407.840,
2526.52148,291.598,3605.09326,407.840,
2526.61279,291.598,3605.18481,407.840,
2526.70435,291.598,3605.27637,407.840,
2526.79590,291.598,3605.36792,408.840,
2526.88745,291.598,3605.45923,407.840,
2526.97900,291.598,3605.55078,408.840,
2527.07056,291.598,3605.64233,408.840,
2527.16211,291.598,3605.73389,408.840,
2527.25366,291.598,3605.82544,408.840,
2527.34497,291.598,3605.91699,408.840,
2527.43652,291.598,3606.00854,408.840,
2527.52808,291.598,3606.09985,409.840,
2527.61963,292.598,3606.19141,409.840,
2527.71118,292.598,3606.28296,409.840,
2527.80273,291.598,3606.37451,409.840,
2527.89429,291.598,3606.46606,409.840,
2527.98584,291.598,3606.55762,409.840,
2528.07715,292.598,3606.64917,409.840,
2528.16870,291.598,3606.74072,409.840,
2528.26025,292.598,3606.83203,410.840,
2528.35181,292.598,3606.92358,409.840,
2528.44336,292.598,3607.01514,410.840,
2528.53491,292.598,3607.10669,410.840,
2528.62646,292.598,3607.19824,410.840,
2528.71777,292.598,3607.28979,410.840,
2528.80933,292.598,3607.38135,410.840,
2528.90088,293.598,3607.47266,410.840,
2528.99243,292.598,3607.56421,411.840,
2529.08398,292.598,3607.65576,411.840,
2529.17554,293.598,3607.74731,411.840,
2529.26709,292.598,3607.83887,411.840,
2529.35864,292.598,3607.93042,411.840,
2529.44995,293.598,3608.02197,411.840,
2529.54150,293.598,3608.11353,411.840,
2529.63306,293.598,3608.20483,411.840,
2529.72461,293.598,3608.29639,411.840,
2529.81616,293.598,3608.38794,412.840,
2529.90771,293.598,3608.47949,411.840,
2529.99927,293.598,3608.57104,411.840,
2530.09058,293.598,3608.66260,412.840,
2530.18213,293.598,3608.75415,412.840,
2530.27368,293.598,3608.84570,411.840,
2530.36523,294.598,3608.93701,412.840,
2530.45679,294.598,3609.02856,413.840,
2530.54834,294.598,3609.12012,413.840,
2530.63989,293.598,3609.21167,413.840,
2530.73145,293.598,3609.30322,413.840,
2530.82275,293.598,3609.39478,413.840,
2530.91431,293.598,3609.48633,413.840,
2531.00586,294.598,3609.57764,413.840,
2531.09741,294.598,3609.66919,413.840,
2531.18896,294.598,3609.76074,413.840,
2531.28052,295.598,3609.85229,413.840,
2531.37207,294.598,3609.94385,413.840,
2531.46362,294.598,3610.03540,414.840,
2531.55493,295.598,3610.12695,414.840,
2531.64648,294.598,3610.21851,414.840,
2531.73804,294.598,3610.30981,414.840,
2531.82959,294.598,3610.40137,414.840,
2531.92114,295.598,3610.49292,415.840,
2532.01270,295.598,3610.58447,415.840,
2532.10425,294.598,3610.67603,414.840,
2532.19556,295.598,3610.76758,415.840,
2532.28711,295.598,3610.85913,415.840,
2532.37866,295.598,3610.95068,414.840,
2532.47021,295.598,3611.04199,415.840,
2532.56177,295.598,3611.13354,415.840,
2532.65332,295.598,3611.22510,415.840,
2532.74487,295.598,3611.31665,415.840,
2532.83643,295.598,3611.40820,416.840,
2532.92773,295.598,3611.49976,415.840,
2533.01929,295.598,3611.59131,416.840,
2533.11084,295.598,3611.68262,416.840,
2533.20239,296.598,3611.77417,416.840,
2533.29395,296.598,3611.86572,416.840,
2533.38550,296.598,3611.95728,416.840,
2533.47705,295.598,3612.04883,416.840,
2533.56860,296.598,3612.14038,416.840,
2533.65991,295.598,3612.23193,416.840,
2533.75146,296.598,3612.32349,417.840,
2533.84302,295.598,3612.41479,417.840,
2533.93457,296.598,3612.50635,417.840,
2534.02612,296.598,3612.59790,417.840,
2534.11768,296.598,3612.68945,417.840,
2534.20923,296.598,3612.78101,417.840,
2534.30054,296.598,3612.87256,417.840,
2534.39209,296.598,3612.96411,417.840,
2534.48364,297.598,3613.05566,418.840,
2534.57520,297.598,3613.14697,417.840,
2534.66675,297.598,3613.23853,417.840,
2534.75830,297.598,3613.33008,418.840,
2534.84985,297.598,3613.42163,419.840,
2534.94141,297.598,3613.51318,419.840,
2535.03271,297.598,3613.60474,418.840,
2535.12427,297.598,3613.69629,418.840,
2535.21582,297.598,3613.78760,419.840,
2535.30737,297.598,3613.87915,419.840,
2535.39893,297.598,3613.97070,419.840,
2535.49048,297.598,3614.06226,419.840,
2535.58203,297.598,3614.15381,419.840,
2535.67334,298.598,3614.24536,419.840,
2535.76489,298.598,3614.33691,419.840,
2535.85645,297.598,3614.42847,420.840,
2535.94800,297.598,3614.51978,420.840,
2536.03955,297.598,3614.61133,420.840,
2536.13110,296.598,3614.70288,420.840,
2536.22266,296.598,3614.79443,420.840,
2536.31421,295.598,3614.88599,420.840,
2536.40552,295.598,3614.97754,420.840,
2536.49707,296.598,3615.06909,420.840,
2536.58862,295.598,3615.16040,420.840,
2536.68018,296.598,3615.25195,420.840,
2536.77173,296.598,3615.34351,421.840,
2536.86328,296.598,3615.43506,420.840,
2536.95483,296.598,3615.52661,420.840,
2537.04639,296.598,3615.61816,421.840,
2537.13770,297.598,3615.70972,421.840,
2537.22925,297.598,3615.80127,421.840,
2537.32080,297.598,3615.89258,421.840,
2537.41235,298.598,3615.98413,421.840,
2537.50391,298.598,3616.07568,421.840,
2537.59546,298.598,3616.16724,421.840,
2537.68701,298.598,3616.25879,421.840,
2537.77832,299.598,3616.35034,422.840,
2537.86987,299.598,3616.44189,422.840,
2537.96143,299.598,3616.53345,422.840,
2538.05298,299.598,3616.62476,422.840,
2538.14453,299.598,3616.71631,422.840,
2538.23608,299.598,3616.80786,422.840,
2538.32764,298.598,3616.89941,423.840,
2538.41919,298.598,3616.99097,423.840,
2538.51050,298.598,3617.08252,423.840,
2538.60205,298.598,3617.17407,423.840,
2538.69360,298.598,3617.26538,423.840,
2538.78516,297.598,3617.35693,423.840,
2538.87671,297.598,3617.44849,423.840,
2538.96826,297.598,3617.54004,423.840,
2539.05981,297.598,3617.63159,423.840,
2539.15137,297.598,3617.72314,424.840,
2539.24268,297.598,3617.81470,425.840,
2539.33423,298.598,3617.90625,424.840,
2539.42578,298.598,3617.99756,424.840,
2539.51733,299.598,3618.08911,424.840,
2539.60889,299.598,3618.18066,425.840,
2539.70044,299.598,3618.27222,425.840,
2539.79199,299.598,3618.36377,426.840,
2539.88330,300.598,3618.45532,425.840,
2539.97485,300.598,3618.54688,426.840,
2540.06641,301.598,3618.63843,425.840,
2540.15796,300.598,3618.72974,426.840,
2540.24951,300.598,3618.82129,426.840,
2540.34106,301.598,3618.91284,426.840,
2540.43262,301.598,3619.00439,426.840,
2540.52417,301.598,3619.09595,427.840,
2540.61548,301.598,3619.18750,426.840,
2540.70703,301.598,3619.27905,426.840,
2540.79858,302.598,3619.37036,426.840,
2540.89014,302.598,3619.46191,426.840,
2540.98169,301.598,3619.55347,426.840,
2541.07324,301.598,3619.64502,426.840,
2541.16479,302.598,3619.73657,427.840,
2541.25610,302.598,3619.82813,426.840,
2541.34766,302.598,3619.91968,427.840,
2541.43921,302.598,3620.01123,427.840,
2541.53076,303.598,3620.10254,427.840,
2541.62231,302.598,3620.19409,427.840,
2541.71387,303.598,3620.28564,427.840,
2541.80542,303.598,3620.37720,427.840,
2541.89697,303.598,3620.46875,428.840,
2541.98828,303.598,3620.56030,428.840,
2542.07983,303.598,3620.65186,428.840,
2542.17139,303.598,3620.74316,428.840,
2542.26294,303.598,3620.83472,429.840,
2542.35449,303.598,3620.92627,428.840,
2542.44604,303.598,3621.01782,429.840,
2542.53760,303.598,3621.10938,428.840,
2542.62915,303.598,3621.20093,429.840,
2542.72046,303.598,3621.29248,429.840,
2542.81201,303.598,3621.38403,429.840,
2542.90356,303.598,3621.47534,429.840,
2542.99512,304.598,3621.56689,429.840,
2543.08667,303.598,3621.65845,429.840,
2543.17822,303.598,3621.75000,429.840,
2543.26978,304.598,3621.84155,430.840,
2543.36108,303.598,3621.93311,429.840,
2543.45264,303.598,3622.02466,430.840,
2543.54419,304.598,3622.11621,430.840,
2543.63574,304.598,3622.20752,431.840,
2543.72729,304.598,3622.29907,430.840,
2543.81885,304.598,3622.39063,431.840,
2543.91040,305.598,3622.48218,430.840,
2544.00195,305.598,3622.57373,431.840,
2544.09326,304.598,3622.66528,431.840,
2544.18481,305.598,3622.75684,431.840,
2544.27637,304.598,3622.84814,431.840,
2544.36792,305.598,3622.93970,431.840,
2544.45947,305.598,3623.03125,431.840,
2544.55103,305.598,3623.12280,431.840,
2544.64258,305.598,3623.21436,431.840,
2544.73413,305.598,3623.30591,431.840,
2544.82544,305.598,3623.39746,432.840,
2544.91699,305.598,3623.48901,432.840,
2545.00854,305.598,3623.58032,432.840,
2545.10010,306.598,3623.67188,433.840,
2545.19165,305.598,3623.76343,432.840,
2545.28320,306.598,3623.85498,433.840,
2545.37476,305.598,3623.94653,433.840,
2545.46606,306.598,3624.03809,433.840,
2545.55762,306.598,3624.12964,433.840,
2545.64917,306.598,3624.22119,433.840,
2545.74072,306.598,3624.31250,433.840,
2545.83228,306.598,3624.40405,433.840,
2545.92383,307.598,3624.49561,433.840,
2546.01538,307.598,3624.58716,433.840,
2546.10693,307.598,3624.67871,433.840,
2546.19824,307.598,3624.77026,434.840,
2546.28979,307.598,3624.86182,434.840,
2546.38135,307.598,3624.95313,434.840,
2546.47290,307.598,3625.04468,434.840,
2546.56445,307.598,3625.13623,435.840,
2546.65601,307.598,3625.22778,434.840,
2546.74756,307.598,3625.31934,435.840,
2546.83911,306.598,3625.41089,434.840,
2546.93042,307.598,3625.50244,435.840,
2547.02197,307.598,3625.59399,434.840,
2547.11353,307.598,3625.68530,435.840,
2547.20508,307.598,3625.77686,435.840,
2547.29663,307.598,3625.86841,435.840,
2547.38818,308.598,3625.95996,435.840,
2547.47974,307.598,3626.05151,435.840,
2547.57104,308.598,3626.14307,436.840,
2547.66260,308.598,3626.23462,436.840,
2547.75415,308.598,3626.32593,436.840,
2547.84570,308.598,3626.41748,436.840,
2547.93726,308.598,3626.50903,436.840,
2548.02881,308.598,3626.60059,437.840,
2548.12036,308.598,3626.69214,436.840,
2548.21191,308.598,3626.78369,437.840,
2548.30322,308.598,3626.87524,437.840,
2548.39478,308.598,3626.96680,437.840,
2548.48633,308.598,3627.05811,437.840,
2548.57788,308.598,3627.14966,437.840,
2548.66943,308.598,3627.24121,437.840,
2548.76099,309.598,3627.33276,437.840,
2548.85254,309.598,3627.42432,437.840,
2548.94385,308.598,3627.51587,437.840,
2549.03540,309.598,3627.60742,437.840,
2549.12695,309.598,3627.69897,438.840,
2549.21851,309.598,3627.79028,438.840,
2549.31006,309.598,3627.88184,437.840,
2549.40161,309.598,3627.97339,438.840,
2549.49316,309.598,3628.06494,438.840,
2549.58472,309.598,3628.15649,438.840,
2549.67603,310.598,3628.24805,438.840,
2549.76758,309.598,3628.33960,438.840,
2549.85913,309.598,3628.43091,439.840,
2549.95068,310.598,3628.52246,439.840,
2550.04224,310.598,3628.61401,439.840,
2550.13379,309.598,3628.70557,439.840,
2550.22534,310.598,3628.79712,439.840,
2550.31689,311.598,3628.88867,440.840,
2550.40820,310.598,3628.98022,439.840,
2550.49976,310.598,3629.07178,439.840,
2550.59131,311.598,3629.16309,439.840,
2550.68286,310.598,3629.25464,439.840,
2550.77441,310.598,3629.34619,440.840,
2550.86597,311.598,3629.43774,440.840,
2550.95752,311.598,3629.52930,441.840,
2551.04883,310.598,3629.62085,440.840,
2551.14038,311.598,3629.71240,440.840,
2551.23193,311.598,3629.80396,441.840,
2551.32349,311.598,3629.89526,441.840,
2551.41504,311.598,3629.98682,441.840,
2551.50659,311.598,3630.07837,441.840,
2551.59814,311.598,3630.16992,441.840,
2551.68970,311.598,3630.26147,441.840,
2551.78101,312.598,3630.35303,441.840,
2551.87256,311.598,3630.44458,441.840,
2551.96411,311.598,3630.53589,442.840,
2552.05566,311.598,3630.62744,442.840,
2552.14722,311.598,3630.71899,442.840,
2552.23877,311.598,3630.81055,442.840,
2552.33032,311.598,3630.90210,442.840,
2552.42188,311.598,3630.99365,443.840,
2552.51318,312.598,3631.08521,442.840,
2552.60474,311.598,3631.17676,442.840,
2552.69629,312.598,3631.26807,442.840,
2552.78784,312.598,3631.35962,442.840,
2552.87939,312.598,3631.45117,443.840,
2552.97095,312.598,3631.54272,442.840,
2553.06250,312.598,3631.63428,443.840,
2553.15381,312.598,3631.72583,443.840,
2553.24536,313.598,3631.81738,443.840,
2553.33691,313.598,3631.90869,444.840,
2553.42847,312.598,3632.00024,443.840,
2553.52002,313.598,3632.09180,444.840,
2553.61157,312.598,3632.18335,444.840,
2553.70313,313.598,3632.27490,444.840,
2553.79468,313.598,3632.36646,444.840,
2553.88599,313.598,3632.45801,445.840,
2553.97754,313.598,3632.54956,444.840,
2554.06909,313.598,3632.64087,444.840,
2554.16064,313.598,3632.73242,445.840,
2554.25220,314.598,3632.82397,445.840,
2554.34375,313.598,3632.91553,445.840,
2554.43530,314.598,3633.00708,445.840,
2554.52661,314.598,3633.09863,445.840,
2554.61816,314.598,3633.19019,445.840,
2554.70972,315.598,3633.28174,445.840,
2554.80127,315.598,3633.37305,445.840,
2554.89282,315.598,3633.46460,445.840,
2554.98438,316.598,3633.55615,445.840,
2555.07593,315.598,3633.64771,446.840,
2555.16748,316.598,3633.73926,446.840,
2555.25879,315.598,3633.83081,446.840,
2555.35034,315.598,3633.92236,446.840,
2555.44189,315.598,3634.01367,447.840,
2555.53345,316.598,3634.10522,446.840,
2555.62500,315.598,3634.19678,447.840,
2555.71655,315.598,3634.28833,447.840,
2555.80811,316.598,3634.37988,447.840,
2555.89966,315.598,3634.47144,447.840,
2555.99097,315.598,3634.56299,447.840,
2556.08252,315.598,3634.65454,447.840,
2556.17407,316.598,3634.74585,447.840,
2556.26563,315.598,3634.83740,447.840,
2556.35718,315.598,3634.92896,447.840,
2556.44873,316.598,3635.02051,448.840,
2556.54028,316.598,3635.11206,448.840,
2556.63159,315.598,3635.20361,448.840,
2556.72314,316.598,3635.29517,448.840,
2556.81470,316.598,3635.38672,449.840,
2556.90625,317.598,3635.47803,449.840,
2556.99780,317.598,3635.56958,449.840,
2557.08936,318.598,3635.66113,449.840,
2557.18091,318.598,3635.75269,449.840,
2557.27246,318.598,3635.84424,449.840,
2557.36377,318.598,3635.93579,449.840,
2557.45532,318.598,3636.02734,449.840,
2557.54688,317.598,3636.11865,449.840,
2557.63843,318.598,3636.21021,449.840,
2557.72998,317.598,3636.30176,449.840,
2557.82153,317.598,3636.39331,449.840,
2557.91309,317.598,3636.48486,450.840,
2558.00464,317.598,3636.57642,449.840,
2558.09595,317.598,3636.66797,449.840,
2558.18750,317.598,3636.75952,450.840,
2558.27905,317.598,3636.85083,450.840,
2558.37061,317.598,3636.94238,450.840,
2558.46216,316.598,3637.03394,450.840,
2558.55371,317.598,3637.12549,450.840,
2558.64526,316.598,3637.21704,450.840,
2558.73657,316.598,3637.30859,451.840,
2558.82813,316.598,3637.40015,450.840,
2558.91968,317.598,3637.49170,451.840,
2559.01123,317.598,3637.58301,450.840,
2559.10278,317.598,3637.67456,451.840,
2559.19434,317.598,3637.76611,451.840,
2559.28589,318.598,3637.85767,451.840,
2559.37744,317.598,3637.94922,451.840,
2559.46875,317.598,3638.04077,451.840,
2559.56030,318.598,3638.13232,451.840,
2559.65186,318.598,3638.22363,451.840,
2559.74341,318.598,3638.31519,452.840,
2559.83496,318.598,3638.40674,452.840,
2559.92651,318.598,3638.49829,452.840,
2560.01807,318.598,3638.58984,452.840,
2560.10938,318.598,3638.68140,452.840,
2560.20093,318.598,3638.77295,452.840,
2560.29248,318.598,3638.86450,453.840,
2560.38403,319.598,3638.95581,453.840,
2560.47559,318.598,3639.04736,452.840,
2560.56714,319.598,3639.13892,453.840,
2560.65869,319.598,3639.23047,453.840,
2560.75024,319.598,3639.32202,453.840,
2560.84155,318.598,3639.41357,453.840,
2560.93311,319.598,3639.50513,453.840,
2561.02466,319.598,3639.59644,453.840,
2561.11621,319.598,3639.68799,453.840,
2561.20776,319.598,3639.77954,455.840,
2561.29932,319.598,3639.87109,454.840,
2561.39087,319.598,3639.96265,454.840,
2561.48242,319.598,3640.05420,455.840,
2561.57373,319.598,3640.14575,455.840,
2561.66528,320.598,3640.23730,454.840,
2561.75684,319.598,3640.32861,455.840,
2561.84839,319.598,3640.42017,455.840,
2561.93994,320.598,3640.51172,455.840,
2562.03149,321.598,3640.60327,456.840,
2562.12305,319.598,3640.69482,455.840,
2562.21436,320.598,3640.78638,456.840,
2562.30591,320.598,3640.87793,455.840,
2562.39746,320.598,3640.96948,456.840,
2562.48901,320.598,3641.06079,456.840,
2562.58057,320.598,3641.15234,456.840,
2562.67212,321.598,3641.24390,457.840,
2562.76367,321.598,3641.33545,457.840,
2562.85522,320.598,3641.42700,456.840,
2562.94653,321.598,3641.51855,457.840,
2563.03809,321.598,3641.61011,457.840,
2563.12964,321.598,3641.70142,457.840,
2563.22119,320.598,3641.79297,457.840,
2563.31274,321.598,3641.88452,457.840,
2563.40430,321.598,3641.97607,458.840,
2563.49585,322.598,3642.06763,457.840,
2563.58740,321.598,3642.15918,457.840,
2563.67871,321.598,3642.25073,458.840,
2563.77026,321.598,3642.34229,458.840,
2563.86182,322.598,3642.43359,458.840,
2563.95337,321.598,3642.52515,458.840,
2564.04492,322.598,3642.61670,458.840,
2564.13647,322.598,3642.70825,458.840,
2564.22803,321.598,3642.79980,459.840,
2564.31934,322.598,3642.89136,458.840,
2564.41089,322.598,3642.98291,459.840,
2564.50244,322.598,3643.07446,459.840,
2564.59399,322.598,3643.16577,459.840,
2564.68555,322.598,3643.25732,459.840,
2564.77710,322.598,3643.34888,459.840,
2564.86865,322.598,3643.44043,459.840,
2564.96021,323.598,3643.53198,460.840,
2565.05151,323.598,3643.62354,460.840,
2565.14307,323.598,3643.71509,459.840,
2565.23462,322.598,3643.80640,460.840,
2565.32617,323.598,3643.89795,461.840,
2565.41772,323.598,3643.98950,460.840,
2565.50928,323.598,3644.08105,460.840,
2565.60083,323.598,3644.17261,461.840,
2565.69214,324.598,3644.26416,460.840,
2565.78369,323.598,3644.35571,461.840,
2565.87524,323.598,3644.44727,461.840,
2565.96680,324.598,3644.53857,461.840,
2566.05835,323.598,3644.63013,461.840,
2566.14990,324.598,3644.72168,461.840,
2566.24146,324.598,3644.81323,461.840,
2566.33301,324.598,3644.90479,462.840,
2566.42432,325.598,3644.99634,461.840,
2566.51587,324.598,3645.08789,461.840,
2566.60742,324.598,3645.17920,462.840,
2566.69897,324.598,3645.27075,462.840,
2566.79053,324.598,3645.36230,462.840,
2566.88208,325.598,3645.45386,462.840,
2566.97363,324.598,3645.54541,462.840,
2567.06519,325.598,3645.63696,463.840,
2567.15649,325.598,3645.72852,463.840,
2567.24805,325.598,3645.82007,463.840,
2567.33960,325.598,3645.91138,463.840,
2567.43115,325.598,3646.00293,463.840,
2567.52271,325.598,3646.09448,463.840,
2567.61426,325.598,3646.18604,463.840,
2567.70581,326.598,3646.27759,463.840,
2567.79712,325.598,3646.36914,463.840,
2567.88867,325.598,3646.46069,463.840,
2567.98022,325.598,3646.55225,463.840,
2568.07178,325.598,3646.64355,464.840,
2568.16333,325.598,3646.73511,463.840,
2568.25488,326.598,3646.82666,464.840,
2568.34644,326.598,3646.91821,464.840,
2568.43799,326.598,3647.00977,464.840,
2568.52930,326.598,3647.10132,465.840,
2568.62085,326.598,3647.19287,464.840,
2568.71240,326.598,3647.28418,464.840,
2568.80396,326.598,3647.37573,465.840,
2568.89551,326.598,3647.46729,465.840,
2568.98706,326.598,3647.55884,465.840,
2569.07861,326.598,3647.65039,465.840,
2569.17017,327.598,3647.74194,465.840,
2569.26147,326.598,3647.83350,465.840,
2569.35303,327.598,3647.92505,465.840,
2569.44458,327.598,3648.01636,465.840,
2569.53613,327.598,3648.10791,466.840,
2569.62769,327.598,3648.19946,466.840,
2569.71924,327.598,3648.29102,466.840,
2569.81079,327.598,3648.38257,466.840,
2569.90210,327.598,3648.47412,467.840,
2569.99365,327.598,3648.56567,467.840,
2570.08521,327.598,3648.65723,466.840,
2570.17676,327.598,3648.74854,467.840,
2570.26831,327.598,3648.84009,467.840,
2570.35986,327.598,3648.93164,467.840,
2570.45142,327.598,3649.02319,467.840,
2570.54297,327.598,3649.11475,467.840,
2570.63428,327.598,3649.20630,467.840,
2570.72583,328.598,3649.29785,467.840,
2570.81738,328.598,3649.38916,467.840,
2570.90894,327.598,3649.48071,467.840,
2571.00049,328.598,3649.57227,468.840,
2571.09204,328.598,3649.66382,468.840,
2571.18359,328.598,3649.75537,467.840,
2571.27515,328.598,3649.84692,468.840,
2571.36646,329.598,3649.93848,468.840,
2571.45801,328.598,3650.03003,469.840,
2571.54956,329.598,3650.12134,468.840,
2571.64111,328.598,3650.21289,469.840,
2571.73267,329.598,3650.30444,469.840,
2571.82422,328.598,3650.39600,469.840,
2571.91577,329.598,3650.48755,469.840,
2572.00708,329.598,3650.57910,469.840,
2572.09863,329.598,3650.67065,469.840,
2572.19019,328.598,3650.76196,469.840,
2572.28174,330.598,3650.85352,470.840,
2572.37329,329.598,3650.94507,470.840,
2572.46484,329.598,3651.03662,470.840,
2572.55640,329.598,3651.12817,470.840,
2572.64795,330.598,3651.21973,470.840,
2572.73926,329.598,3651.31128,470.840,
2572.83081,329.598,3651.40283,471.840,
2572.92236,330.598,3651.49414,472.840,
2573.01392,330.598,3651.58569,471.840,
2573.10547,330.598,3651.67725,471.840,
2573.19702,330.598,3651.76880,471.840,
2573.28857,330.598,3651.86035,471.840,
2573.37988,330.598,3651.95190,471.840,
2573.47144,330.598,3652.04346,472.840,
2573.56299,330.598,3652.13501,471.840,
2573.65454,330.598,3652.22632,472.840,
2573.74609,331.598,3652.31787,471.840,
2573.83765,330.598,3652.40942,472.840,
2573.92920,330.598,3652.50098,472.840,
2574.02075,330.598,3652.59253,472.840,
2574.11206,330.598,3652.68408,472.840,
2574.20361,330.598,3652.77563,472.840,
2574.29517,329.598,3652.86694,473.840,
2574.38672,329.598,3652.95850,473.840,
2574.47827,329.598,3653.05005,473.840,
2574.56982,329.598,3653.14160,473.840,
2574.66138,328.598,3653.23315,473.840,
2574.75293,329.598,3653.32471,473.840,
2574.84424,329.598,3653.41626,473.840,
2574.93579,329.598,3653.50781,473.840,
2575.02734,329.598,3653.59912,474.840,
2575.11890,330.598,3653.69067,473.840,
2575.21045,330.598,3653.78223,473.840,
2575.30200,330.598,3653.87378,474.840,
2575.39355,331.598,3653.96533,474.840,
2575.48486,331.598,3654.05688,474.840,
2575.57642,331.598,3654.14844,474.840,
2575.66797,332.598,3654.23999,475.840,
2575.75952,332.598,3654.33130,474.840,
2575.85107,332.598,3654.42285,475.840,
2575.94263,332.598,3654.51440,475.840,
2576.03418,332.598,3654.60596,475.840,
2576.12573,331.598,3654.69751,475.840,
2576.21704,332.598,3654.78906,476.840,
2576.30859,332.598,3654.88062,475.840,
2576.40015,332.598,3654.97192,476.840,
2576.49170,331.598,3655.06348,476.840,
2576.58325,331.598,3655.15503,476.840,
2576.67480,331.598,3655.24658,476.840,
2576.76636,330.598,3655.33813,476.840,
2576.85791,330.598,3655.42969,476.840,
2576.94922,330.598,3655.52124,476.840,
2577.04077,330.598,3655.61279,476.840,
2577.13232,330.598,3655.70410,477.840,
2577.22388,331.598,3655.79565,476.840,
2577.31543,331.598,3655.88721,477.840,
2577.40698,332.598,3655.97876,477.840,
2577.49854,332.598,3656.07031,477.840,
2577.58984,332.598,3656.16187,477.840,
2577.68140,332.598,3656.25342,477.840,
2577.77295,332.598,3656.34497,477.840,
2577.86450,333.598,3656.43628,478.840,
2577.95605,333.598,3656.52783,478.840,
2578.04761,333.598,3656.61938,478.840,
2578.13916,334.598,3656.71094,478.840,
2578.23071,334.598,3656.80249,478.840,
2578.32202,334.598,3656.89404,478.840,
2578.41357,334.598,3656.98560,478.840,
2578.50513,334.598,3657.07690,478.840,
2578.59668,334.598,3657.16846,479.840,
2578.68823,335.598,3657.26001,479.840,
2578.77979,335.598,3657.35156,479.840,
2578.87134,334.598,3657.44312,479.840,
2578.96265,335.598,3657.53467,479.840,
2579.05420,335.598,3657.62622,479.840,
2579.14575,335.598,3657.71777,480.840,
2579.23730,335.598,3657.80908,480.840,
2579.32886,335.598,3657.90063,480.840,
2579.42041,335.598,3657.99219,480.840,
2579.51196,335.598,3658.08374,481.840,
2579.60352,336.598,3658.17529,480.840,
2579.69482,336.598,3658.26685,480.840,
2579.78638,336.598,3658.35840,480.840,
2579.87793,336.598,3658.44971,481.840,
2579.96948,336.598,3658.54126,482.840,
2580.06104,335.598,3658.63281,482.840,
2580.15259,336.598,3658.72437,482.840,
2580.24414,336.598,3658.81592,483.840,
2580.33569,336.598,3658.90747,483.840,
2580.42700,336.598,3658.99902,484.840,
2580.51855,336.598,3659.09058,484.840,
2580.61011,336.598,3659.18188,483.840,
2580.70166,336.598,3659.27344,483.840,
2580.79321,337.598,3659.36499,483.840,
2580.88477,337.598,3659.45654,483.840,
2580.97632,337.598,3659.54810,483.840,
2581.06763,337.598,3659.63965,483.840,
2581.15918,337.598,3659.73120,483.840,
2581.25073,337.598,3659.82275,483.840,
2581.34229,337.598,3659.91406,483.840,
2581.43384,337.598,3660.00562,483.840,
2581.52539,338.598,3660.09717,483.840,
2581.61694,338.598,3660.18872,483.840,
2581.70850,337.598,3660.28027,484.840,
2581.79980,338.598,3660.37183,484.840,
2581.89136,337.598,3660.46338,483.840,
2581.98291,337.598,3660.55469,484.840,
2582.07446,338.598,3660.64624,483.840,
2582.16602,338.598,3660.73779,483.840,
2582.25757,338.598,3660.82935,483.840,
2582.34912,338.598,3660.92090,484.840,
2582.44067,338.598,3661.01245,484.840,
2582.53198,339.598,3661.10400,485.840,
2582.62354,338.598,3661.19556,484.840,
2582.71509,338.598,3661.28687,485.840,
2582.80664,339.598,3661.37842,485.840,
2582.89819,338.598,3661.46997,485.840,
2582.98975,339.598,3661.56152,485.840,
2583.08130,339.598,3661.65308,486.840,
2583.17261,339.598,3661.74463,486.840,
2583.26416,339.598,3661.83618,486.840,
2583.35571,339.598,3661.92773,486.840,
2583.44727,339.598,3662.01904,486.840,
2583.53882,339.598,3662.11060,487.840,
2583.63037,339.598,3662.20215,486.840,
2583.72192,339.598,3662.29370,487.840,
2583.81348,339.598,3662.38525,487.840,
2583.90479,339.598,3662.47681,487.840,
2583.99634,340.598,3662.56836,487.840,
2584.08789,339.598,3662.65967,487.840,
2584.17944,339.598,3662.75122,487.840,
2584.27100,340.598,3662.84277,487.840,
2584.36255,340.598,3662.93433,487.840,
2584.45410,340.598,3663.02588,487.840,
2584.54541,340.598,3663.11743,487.840,
2584.63696,340.598,3663.20898,488.840,
2584.72852,340.598,3663.30054,488.840,
2584.82007,340.598,3663.39185,487.840,
2584.91162,340.598,3663.48340,488.840,
2585.00317,340.598,3663.57495,488.840,
2585.09473,340.598,3663.66650,488.840,
2585.18628,341.598,3663.75806,488.840,
2585.27759,340.598,3663.84961,489.840,
2585.36914,341.598,3663.94116,489.840,
2585.46069,341.598,3664.03247,489.840,
2585.55225,341.598,3664.12402,489.840,
2585.64380,341.598,3664.21558,489.840,
2585.73535,341.598,3664.30713,489.840,
2585.82690,341.598,3664.39868,489.840,
2585.91846,341.598,3664.49023,490.840,
2586.00977,341.598,3664.58179,489.840,
2586.10132,341.598,3664.67334,490.840,
2586.19287,341.598,3664.76465,490.840,
2586.28442,341.598,3664.85620,490.840,
2586.37598,342.598,3664.94775,490.840,
2586.46753,341.598,3665.03931,490.840,
2586.55908,341.598,3665.13086,491.840,
2586.65039,342.598,3665.22241,491.840,
2586.74194,342.598,3665.31396,491.840,
2586.83350,342.598,3665.40552,491.840,
2586.92505,343.598,3665.49683,491.840,
2587.01660,342.598,3665.58838,491.840,
2587.10815,342.598,3665.67993,491.840,
2587.19971,342.598,3665.77148,492.840,
2587.29126,342.598,3665.86304,491.840,
2587.38257,342.598,3665.95459,491.840,
2587.47412,342.598,3666.04614,492.840,
2587.56567,342.598,3666.13745,492.840,
2587.65723,342.598,3666.22900,492.840,
2587.74878,342.598,3666.32056,492.840,
2587.84033,343.598,3666.41211,493.840,
2587.93188,343.598,3666.50366,492.840,
2588.02344,343.598,3666.59521,493.840,
2588.11475,343.598,3666.68677,493.840,
2588.20630,343.598,3666.77832,492.840,
2588.29785,343.598,3666.86963,493.840,
2588.38940,343.598,3666.96118,493.840,
2588.48096,344.598,3667.05273,493.840,
2588.57251,343.598,3667.14429,493.840,
2588.66406,344.598,3667.23584,494.840,
2588.75537,344.598,3667.32739,493.840,
2588.84692,344.598,3667.41895,493.840,
2588.93848,343.598,3667.51050,494.840,
2589.03003,344.598,3667.60181,494.840,
2589.12158,344.598,3667.69336,494.840,
2589.21313,343.598,3667.78491,494.840,
2589.30469,343.598,3667.87646,495.840,
2589.39624,344.598,3667.96802,494.840,
2589.48755,344.598,3668.05957,494.840,
2589.57910,344.598,3668.15112,494.840,
2589.67065,344.598,3668.24243,495.840,
2589.76221,344.598,3668.33398,495.840,
2589.85376,345.598,3668.42554,495.840,
2589.94531,344.598,3668.51709,495.840,
2590.03687,345.598,3668.60864,495.840,
2590.12842,344.598,3668.70020,495.840,
2590.21973,345.598,3668.79175,495.840,
2590.31128,345.598,3668.88330,496.840,
2590.40283,345.598,3668.97461,496.840,
2590.49438,345.598,3669.06616,497.840,
2590.58594,345.598,3669.15771,496.840,
2590.67749,345.598,3669.24927,496.840,
2590.76904,345.598,3669.34082,497.840,
2590.86035,345.598,3669.43237,496.840,
2590.95190,346.598,3669.52393,497.840,
2591.04346,346.598,3669.61523,497.840,
2591.13501,346.598,3669.70679,497.840,
2591.22656,346.598,3669.79834,497.840,
2591.31812,347.598,3669.88989,497.840,
2591.40967,346.598,3669.98145,497.840,
2591.50122,346.598,3670.07300,497.840,
2591.59253,346.598,3670.16455,497.840,
2591.68408,346.598,3670.25610,498.840,
2591.77563,347.598,3670.34741,498.840,
2591.86719,347.598,3670.43896,498.840,
2591.95874,347.598,3670.53052,499.840,
2592.05029,347.598,3670.62207,498.840,
2592.14185,347.598,3670.71362,498.840,
2592.23315,347.598,3670.80518,498.840,
2592.32471,347.598,3670.89673,499.840,
2592.41626,347.598,3670.98828,498.840,
2592.50781,348.598,3671.07959,499.840,
2592.59937,347.598,3671.17114,499.840,
2592.69092,347.598,3671.26270,499.840,
2592.78247,348.598,3671.35425,499.840,
2592.87402,348.598,3671.44580,499.840,
2592.96533,347.598,3671.53735,499.840,
2593.05688,348.598,3671.62891,500.840,
2593.14844,348.598,3671.72021,499.840,
2593.23999,348.598,3671.81177,500.840,
2593.33154,347.598,3671.90332,500.840,
2593.42310,348.598,3671.99487,500.840,
2593.51465,348.598,3672.08643,500.840,
2593.60620,348.598,3672.17798,501.840,
2593.69751,348.598,3672.26953,500.840,
2593.78906,348.598,3672.36108,501.840,
2593.88062,348.598,3672.45239,501.840,
2593.97217,348.598,3672.54395,501.840,
2594.06372,348.598,3672.63550,501.840,
2594.15527,348.598,3672.72705,502.840,
2594.24683,349.598,3672.81860,501.840,
2594.33813,349.598,3672.91016,501.840,
2594.42969,349.598,3673.00171,502.840,
2594.52124,350.598,3673.09326,502.840,
2594.61279,351.598,3673.18457,501.840,
2594.70435,351.598,3673.27612,502.840,
2594.79590,351.598,3673.36768,503.840,
2594.88745,351.598,3673.45923,503.840,
2594.97900,351.598,3673.55078,502.840,
2595.07031,351.598,3673.64233,502.840,
2595.16187,351.598,3673.73389,502.840,
2595.25342,351.598,3673.82520,503.840,
2595.34497,351.598,3673.91675,503.840,
2595.43652,351.598,3674.00830,503.840,
2595.52808,351.598,3674.09985,503.840,
2595.61963,351.598,3674.19141,503.840,
2595.71118,351.598,3674.28296,503.840,
2595.80249,351.598,3674.37451,503.840,
2595.89404,351.598,3674.46606,503.840,
2595.98560,350.598,3674.55737,504.840,
2596.07715,351.598,3674.64893,504.840,
2596.16870,351.598,3674.74048,504.840,
2596.26025,351.598,3674.83203,504.840,
2596.35181,351.598,3674.92358,505.840,
2596.44312,350.598,3675.01514,505.840,
2596.53467,350.598,3675.10669,505.840,
2596.62622,349.598,3675.19824,505.840,
2596.71777,350.598,3675.28955,504.840,
2596.80933,349.598,3675.38110,505.840,
2596.90088,348.598,3675.47266,505.840,
2596.99243,349.598,3675.56421,506.840,
2597.08398,349.598,3675.65576,506.840,
2597.17529,349.598,3675.74731,506.840,
2597.26685,349.598,3675.83887,506.840,
2597.35840,349.598,3675.93018,506.840,
2597.44995,350.598,3676.02173,506.840,
2597.54150,350.598,3676.11328,506.840,
2597.63306,351.598,3676.20483,506.840,
2597.72461,351.598,3676.29639,506.840,
2597.81592,350.598,3676.38794,508.840,
2597.90747,351.598,3676.47949,507.840,
2597.99902,351.598,3676.57104,507.840,
2598.09058,351.598,3676.66235,507.840,
2598.18213,351.598,3676.75391,507.840,
2598.27368,352.598,3676.84546,507.840,
2598.36523,352.598,3676.93701,507.840,
2598.45679,352.598,3677.02856,507.840,
2598.54810,353.598,3677.12012,507.840,
2598.63965,353.598,3677.21167,507.840,
2598.73120,352.598,3677.30298,507.840,
2598.82275,353.598,3677.39453,507.840,
2598.91431,353.598,3677.48608,508.840,
2599.00586,353.598,3677.57764,508.840,
2599.09741,353.598,3677.66919,508.840,
2599.18896,353.598,3677.76074,508.840,
2599.28027,353.598,3677.85229,509.840,
2599.37183,353.598,3677.94385,509.840,
2599.46338,353.598,3678.03516,509.840,
2599.55493,353.598,3678.12671,509.840,
2599.64648,353.598,3678.21826,509.840,
2599.73804,353.598,3678.30981,510.840,
2599.82959,354.598,3678.40137,509.840,
2599.92090,354.598,3678.49292,509.840,
2600.01245,353.598,3678.58447,510.840,
2600.10400,354.598,3678.67603,510.840,
2600.19556,354.598,3678.76733,510.840,
2600.28711,354.598,3678.85889,510.840,
2600.37866,354.598,3678.95044,510.840,
2600.47021,354.598,3679.04199,510.840,
2600.56177,354.598,3679.13354,511.840,
2600.65308,354.598,3679.22510,511.840,
2600.74463,355.598,3679.31665,512.840,
2600.83618,354.598,3679.40796,511.840,
2600.92773,354.598,3679.49951,512.840,
2601.01929,355.598,3679.59106,511.840,
2601.11084,354.598,3679.68262,512.840,
2601.20239,354.598,3679.77417,512.840,
2601.29395,355.598,3679.86572,512.840,
2601.38525,355.598,3679.95728,512.840,
2601.47681,355.598,3680.04883,512.840,
2601.56836,355.598,3680.14014,512.840,
2601.65991,355.598,3680.23169,512.840,
2601.75146,356.598,3680.32324,512.840,
2601.84302,355.598,3680.41479,512.840,
2601.93457,356.598,3680.50635,512.840,
2602.02588,356.598,3680.59790,512.840,
2602.11743,356.598,3680.68945,513.840,
2602.20898,356.598,3680.78101,513.840,
2602.30054,356.598,3680.87231,513.840,
2602.39209,356.598,3680.96387,513.840,
2602.48364,356.598,3681.05542,513.840,
2602.57520,355.598,3681.14697,513.840,
2602.66675,356.598,3681.23853,513.840,
2602.75806,356.598,3681.33008,513.840,
2602.84961,356.598,3681.42163,514.840,
2602.94116,356.598,3681.51294,514.840,
2603.03271,357.598,3681.60449,514.840,
2603.12427,356.598,3681.69604,514.840,
2603.21582,356.598,3681.78760,515.840,
2603.30737,357.598,3681.87915,515.840,
2603.39868,356.598,3681.97070,514.840,
2603.49023,357.598,3682.06226,515.840,
2603.58179,357.598,3682.15381,515.840,
2603.67334,357.598,3682.24512,516.840,
2603.76489,357.598,3682.33667,515.840,
2603.85645,357.598,3682.42822,515.840,
2603.94800,357.598,3682.51978,515.840,
2604.03955,357.598,3682.61133,516.840,
2604.13086,357.598,3682.70288,516.840,
2604.22241,357.598,3682.79443,516.840,
2604.31396,357.598,3682.88574,516.840,
2604.40552,357.598,3682.97729,516.840,
2604.49707,358.598,3683.06885,516.840,
2604.58862,357.598,3683.16040,516.840,
2604.68018,358.598,3683.25195,516.840,
2604.77173,358.598,3683.34351,516.840,
2604.86304,358.598,3683.43506,517.840,
2604.95459,358.598,3683.52661,517.840,
2605.04614,358.598,3683.61792,517.840,
2605.13770,358.598,3683.70947,518.840,
2605.22925,359.598,3683.80103,517.840,
2605.32080,358.598,3683.89258,517.840,
2605.41235,358.598,3683.98413,518.840,
2605.50366,359.598,3684.07568,518.840,
2605.59521,359.598,3684.16724,518.840,
2605.68677,359.598,3684.25879,518.840,
2605.77832,359.598,3684.35010,519.840,
2605.86987,359.598,3684.44165,518.840,
2605.96143,360.598,3684.53320,519.840,
2606.05298,359.598,3684.62476,519.840,
2606.14453,359.598,3684.71631,519.840,
2606.23584,359.598,3684.80786,519.840,
2606.32739,360.598,3684.89941,519.840,
2606.41895,359.598,3684.99072,520.840,
2606.51050,359.598,3685.08228,519.840,
2606.60205,360.598,3685.17383,520.840,
2606.69360,360.598,3685.26538,520.840,
2606.78516,360.598,3685.35693,520.840,
2606.87671,360.598,3685.44849,520.840,
2606.96802,360.598,3685.54004,521.840,
2607.05957,360.598,3685.63159,520.840,
2607.15112,360.598,3685.72290,520.840,
2607.24268,360.598,3685.81445,520.840,
2607.33423,360.598,3685.90601,520.840,
2607.42578,361.598,3685.99756,521.840,
2607.51733,361.598,3686.08911,521.840,
2607.60864,361.598,3686.18066,520.840,
2607.70020,361.598,3686.27222,521.840,
2607.79175,361.598,3686.36377,521.840,
2607.88330,361.598,3686.45508,521.840,
2607.97485,361.598,3686.54663,521.840,
2608.06641,361.598,3686.63818,522.840,
2608.15796,361.598,3686.72974,521.840,
2608.24951,361.598,3686.82129,522.840,
2608.34082,361.598,3686.91284,522.840,
2608.43237,361.598,3687.00439,522.840,
2608.52393,361.598,3687.09570,522.840,
2608.61548,362.598,3687.18726,522.840,
2608.70703,361.598,3687.27881,523.840,
2608.79858,361.598,3687.37036,523.840,
2608.89014,363.598,3687.46191,523.840,
2608.98169,362.598,3687.55347,522.840,
2609.07300,362.598,3687.64502,523.840,
2609.16455,362.598,3687.73657,523.840,
2609.25610,362.598,3687.82788,522.840,
2609.34766,362.598,3687.91943,523.840,
2609.43921,362.598,3688.01099,524.840,
2609.53076,363.598,3688.10254,524.840,
2609.62231,363.598,3688.19409,524.840,
2609.71362,362.598,3688.28564,524.840,
2609.80518,363.598,3688.37720,524.840,
2609.89673,363.598,3688.46851,524.840,
2609.98828,362.598,3688.56006,524.840,
2610.07983,363.598,3688.65161,525.840,
2610.17139,363.598,3688.74316,524.840,
2610.26294,363.598,3688.83472,524.840,
2610.35449,363.598,3688.92627,525.840,
2610.44580,363.598,3689.01782,525.840,
2610.53735,363.598,3689.10938,525.840,
2610.62891,363.598,3689.20068,526.840,
2610.72046,363.598,3689.29224,525.840,
2610.81201,363.598,3689.38379,526.840,
2610.90356,363.598,3689.47534,526.840,
2610.99512,363.598,3689.56689,527.840,
2611.08643,363.598,3689.65845,526.840,
2611.17798,363.598,3689.75000,526.840,
2611.26953,363.598,3689.84155,527.840,
2611.36108,363.598,3689.93286,527.840,
2611.45264,364.598,3690.02441,526.840,
2611.54419,364.598,3690.11597,527.840,
2611.63574,364.598,3690.20752,527.840,
2611.72729,365.598,3690.29907,527.840,
2611.81860,365.598,3690.39063,527.840,
2611.91016,363.598,3690.48218,527.840,
2612.00171,364.598,3690.57349,527.840,
2612.09326,365.598,3690.66504,528.840,
2612.18481,364.598,3690.75659,528.840,
2612.27637,365.598,3690.84814,528.840,
2612.36792,365.598,3690.93970,528.840,
2612.45947,364.598,3691.03125,529.840,
2612.55078,365.598,3691.12280,528.840,
2612.64233,365.598,3691.21436,529.840,
2612.73389,365.598,3691.30566,529.840,
2612.82544,365.598,3691.39722,529.840,
2612.91699,365.598,3691.48877,529.840,
2613.00854,365.598,3691.58032,530.840,
2613.10010,365.598,3691.67188,530.840,
2613.19141,366.598,3691.76343,530.840,
2613.28296,366.598,3691.85498,530.840,
2613.37451,366.598,3691.94653,530.840,
2613.46606,366.598,3692.03784,530.840,
2613.55762,366.598,3692.12939,530.840,
2613.64917,366.598,3692.22095,531.840,
2613.74072,366.598,3692.31250,531.840,
2613.83228,366.598,3692.40405,530.840,
2613.92358,366.598,3692.49561,531.840,
2614.01514,366.598,3692.58716,531.840,
2614.10669,366.598,3692.67847,531.840,
2614.19824,366.598,3692.77002,531.840,
2614.28979,366.598,3692.86157,531.840,
2614.38135,367.598,3692.95313,531.840,
2614.47290,367.598,3693.04468,531.840,
2614.56445,367.598,3693.13623,531.840,
2614.65576,367.598,3693.22778,531.840,
2614.74731,367.598,3693.31934,532.840,
2614.83887,367.598,3693.41064,532.840,
2614.93042,367.598,3693.50220,532.840,
2615.02197,367.598,3693.59375,532.840,
2615.11353,367.598,3693.68530,532.840,
2615.20508,367.598,3693.77686,533.840,
2615.29639,367.598,3693.86841,533.840,
2615.38794,367.598,3693.95996,533.840,
2615.47949,366.598,3694.05151,533.840,
2615.57104,366.598,3694.14282,533.840,
2615.66260,365.598,3694.23438,533.840,
2615.75415,365.598,3694.32593,534.840,
2615.84570,364.598,3694.41748,533.840,
2615.93726,365.598,3694.50903,533.840,
2616.02856,365.598,3694.60059,534.840,
2616.12012,365.598,3694.69214,534.840,
2616.21167,366.598,3694.78345,534.840,
2616.30322,366.598,3694.87500,534.840,
2616.39478,366.598,3694.96655,535.840,
2616.48633,366.598,3695.05811,535.840,
2616.57788,367.598,3695.14966,534.840,
2616.66919,367.598,3695.24121,535.840,
2616.76074,368.598,3695.33276,535.840,
2616.85229,367.598,3695.42432,535.840,
2616.94385,368.598,3695.51563,535.840,
2617.03540,368.598,3695.60718,535.840,
2617.12695,368.598,3695.69873,535.840,
2617.21851,369.598,3695.79028,535.840,
2617.31006,369.598,3695.88184,536.840,
2617.40137,369.598,3695.97339,536.840,
2617.49292,369.598,3696.06494,536.840,
2617.58447,370.598,3696.15625,536.840,
2617.67603,371.598,3696.24780,536.840,
2617.76758,371.598,3696.33936,536.840,
2617.85913,371.598,3696.43091,536.840,
2617.95068,372.598,3696.52246,537.840,
2618.04224,372.598,3696.61401,537.840,
2618.13354,372.598,3696.70557,537.840,
2618.22510,372.598,3696.79712,537.840,
2618.31665,372.598,3696.88843,538.840,
2618.40820,372.598,3696.97998,538.840,
2618.49976,372.598,3697.07153,538.840,
2618.59131,371.598,3697.16309,538.840,
2618.68286,371.598,3697.25464,538.840,
2618.77417,372.598,3697.34619,539.840,
2618.86572,371.598,3697.43774,539.840,
2618.95728,371.598,3697.52930,539.840,
2619.04883,371.598,3697.62061,539.840,
2619.14038,372.598,3697.71216,539.840,
2619.23193,371.598,3697.80371,540.840,
2619.32349,371.598,3697.89526,539.840,
2619.41504,371.598,3697.98682,539.840,
2619.50635,371.598,3698.07837,539.840,
2619.59790,371.598,3698.16992,539.840,
2619.68945,372.598,3698.26123,540.840,
2619.78101,372.598,3698.35278,540.840,
2619.87256,372.598,3698.44434,540.840,
2619.96411,372.598,3698.53589,540.840,
2620.05566,372.598,3698.62744,540.840,
2620.14722,372.598,3698.71899,540.840,
2620.23853,372.598,3698.81055,540.840,
2620.33008,372.598,3698.90210,540.840,
2620.42163,372.598,3698.99341,540.840,
2620.51318,372.598,3699.08496,541.840,
2620.60474,373.598,3699.17651,541.840,
2620.69629,373.598,3699.26807,541.840,
2620.78784,372.598,3699.35962,541.840,
2620.87915,373.598,3699.45117,541.840,
2620.97070,373.598,3699.54272,541.840,
2621.06226,373.598,3699.63428,541.840,
2621.15381,373.598,3699.72559,541.840,
2621.24536,373.598,3699.81714,542.840,
2621.33691,373.598,3699.90869,542.840,
2621.42847,373.598,3700.00024,542.840,
2621.52002,373.598,3700.09180,542.840,
2621.61133,373.598,3700.18335,543.840,
2621.70288,374.598,3700.27490,542.840,
2621.79443,374.598,3700.36621,542.840,
2621.88599,374.598,3700.45776,543.840,
2621.97754,373.598,3700.54932,543.840,
2622.06909,374.598,3700.64087,542.840,
2622.16064,374.598,3700.73242,543.840,
2622.25195,374.598,3700.82397,543.840,
2622.34351,374.598,3700.91553,543.840,
2622.43506,375.598,3701.00708,544.840,
2622.52661,375.598,3701.09839,544.840,
2622.61816,375.598,3701.18994,544.840,
2622.70972,374.598,3701.28149,545.840,
2622.80127,375.598,3701.37305,545.840,
2622.89282,374.598,3701.46460,545.840,
2622.98413,375.598,3701.55615,545.840,
2623.07568,375.598,3701.64771,545.840,
2623.16724,375.598,3701.73901,545.840,
2623.25879,375.598,3701.83057,546.840,
2623.35034,375.598,3701.92212,545.840,
2623.44189,375.598,3702.01367,546.840,
2623.53345,376.598,3702.10522,546.840,
2623.62500,376.598,3702.19678,546.840,
2623.71631,375.598,3702.28833,546.840,
2623.80786,376.598,3702.37988,546.840,
2623.89941,376.598,3702.47119,546.840,
2623.99097,376.598,3702.56274,546.840,
2624.08252,376.598,3702.65430,547.840,
2624.17407,376.598,3702.74585,547.840,
2624.26563,376.598,3702.83740,547.840,
2624.35693,376.598,3702.92896,547.840,
2624.44849,376.598,3703.02051,547.840,
2624.54004,376.598,3703.11206,547.840,
2624.63159,376.598,3703.20337,548.840,
2624.72314,376.598,3703.29492,548.840,
2624.81470,377.598,3703.38647,548.840,
2624.90625,377.598,3703.47803,548.840,
2624.99780,377.598,3703.56958,549.840,
2625.08911,377.598,3703.66113,548.840,
2625.18066,377.598,3703.75269,549.840,
2625.27222,377.598,3703.84399,549.840,
2625.36377,377.598,3703.93555,548.840,
2625.45532,377.598,3704.02710,548.840,
2625.54688,377.598,3704.11865,549.840,
2625.63843,377.598,3704.21021,550.840,
2625.72998,377.598,3704.30176,549.840,
2625.82129,378.598,3704.39331,550.840,
2625.91284,378.598,3704.48486,549.840,
2626.00439,378.598,3704.57617,550.840,
2626.09595,378.598,3704.66772,550.840,
2626.18750,378.598,3704.75928,550.840,
2626.27905,378.598,3704.85083,550.840,
2626.37061,378.598,3704.94238,550.840,
2626.46191,379.598,3705.03394,551.840,
2626.55347,379.598,3705.12549,551.840,
2626.64502,379.598,3705.21704,551.840,
2626.73657,378.598,3705.30835,551.840,
2626.82813,379.598,3705.39990,551.840,
2626.91968,378.598,3705.49146,551.840,
2627.01123,379.598,3705.58301,551.840,
2627.10278,379.598,3705.67456,551.840,
2627.19409,378.598,3705.76611,552.840,
2627.28564,379.598,3705.85767,552.840,
2627.37720,379.598,3705.94897,552.840,
2627.46875,379.598,3706.04053,552.840,
2627.56030,379.598,3706.13208,552.840,
2627.65186,379.598,3706.22363,552.840,
2627.74341,380.598,3706.31519,553.840,
2627.83496,379.598,3706.40674,552.840,
2627.92627,380.598,3706.49829,553.840,
2628.01782,380.598,3706.58984,553.840,
2628.10938,380.598,3706.68115,553.840,
2628.20093,380.598,3706.77271,553.840,
2628.29248,381.598,3706.86426,554.840,
2628.38403,380.598,3706.95581,553.840,
2628.47559,381.598,3707.04736,554.840,
2628.56689,381.598,3707.13892,555.840,
2628.65845,380.598,3707.23047,554.840,
2628.75000,380.598,3707.32178,554.840,
2628.84155,381.598,3707.41333,554.840,
2628.93311,381.598,3707.50488,555.840,
2629.02466,381.598,3707.59644,554.840,
2629.11621,381.598,3707.68799,555.840,
2629.20776,381.598,3707.77954,555.840,
2629.29907,381.598,3707.87109,555.840,
2629.39063,382.598,3707.96265,555.840,
2629.48218,382.598,3708.05396,555.840,
2629.57373,381.598,3708.14551,556.840,
2629.66528,381.598,3708.23706,556.840,
2629.75684,381.598,3708.32861,556.840,
2629.84839,382.598,3708.42017,556.840,
2629.93970,382.598,3708.51172,556.840,
2630.03125,382.598,3708.60327,557.840,
2630.12280,382.598,3708.69482,557.840,
2630.21436,382.598,3708.78613,557.840,
2630.30591,383.598,3708.87769,557.840,
2630.39746,382.598,3708.96924,557.840,
2630.48901,382.598,3709.06079,557.840,
2630.58057,382.598,3709.15234,557.840,
2630.67188,383.598,3709.24390,557.840,
2630.76343,383.598,3709.33545,558.840,
2630.85498,383.598,3709.42676,558.840,
2630.94653,383.598,3709.51831,558.840,
2631.03809,383.598,3709.60986,558.840,
2631.12964,383.598,3709.70142,558.840,
2631.22119,383.598,3709.79297,557.840,
2631.31274,383.598,3709.88452,558.840,
2631.40405,383.598,3709.97607,558.840,
2631.49561,383.598,3710.06763,559.840,
2631.58716,383.598,3710.15894,559.840,
2631.67871,383.598,3710.25049,559.840,
2631.77026,383.598,3710.34204,559.840,
2631.86182,383.598,3710.43359,559.840,
2631.95337,383.598,3710.52515,560.840,
2632.04468,383.598,3710.61670,559.840,
2632.13623,384.598,3710.70825,560.840,
2632.22778,384.598,3710.79980,560.840,
2632.31934,384.598,3710.89111,560.840,
2632.41089,384.598,3710.98267,560.840,
2632.50244,384.598,3711.07422,560.840,
2632.59399,384.598,3711.16577,561.840,
2632.68555,384.598,3711.25732,560.840,
2632.77686,384.598,3711.34888,561.840,
2632.86841,384.598,3711.44043,561.840,
2632.95996,384.598,3711.53174,562.840,
2633.05151,384.598,3711.62329,561.840,
2633.14307,384.598,3711.71484,561.840,
2633.23462,384.598,3711.80640,561.840,
2633.32617,384.598,3711.89795,562.840,
2633.41772,385.598,3711.98950,562.840,
2633.50903,385.598,3712.08105,562.840,
2633.60059,385.598,3712.17261,562.840,
2633.69214,385.598,3712.26392,562.840,
2633.78369,386.598,3712.35547,563.840,
2633.87524,386.598,3712.44702,562.840,
2633.96680,385.598,3712.53857,563.840,
2634.05835,386.598,3712.63013,563.840,
2634.14966,385.598,3712.72168,563.840,
2634.24121,386.598,3712.81323,563.840,
2634.33276,386.598,3712.90454,563.840,
2634.42432,386.598,3712.99609,564.840,
2634.51587,386.598,3713.08765,563.840,
2634.60742,386.598,3713.17920,564.840,
2634.69897,386.598,3713.27075,564.840,
2634.79053,386.598,3713.36230,564.840,
2634.88184,386.598,3713.45386,564.840,
2634.97339,386.598,3713.54541,564.840,
2635.06494,387.598,3713.63672,565.840,
2635.15649,386.598,3713.72827,565.840,
2635.24805,387.598,3713.81982,565.840,
2635.33960,387.598,3713.91138,565.840,
2635.43115,387.598,3714.00293,565.840,
2635.52246,387.598,3714.09448,565.840,
2635.61401,387.598,3714.18604,565.840,
2635.70557,387.598,3714.27759,565.840,
2635.79712,387.598,3714.36890,566.840,
2635.88867,387.598,3714.46045,567.840,
2635.98022,388.598,3714.55200,566.840,
2636.07178,387.598,3714.64355,566.840,
2636.16333,388.598,3714.73511,567.840,
2636.25464,387.598,3714.82666,567.840,
2636.34619,388.598,3714.91821,566.840,
2636.43774,388.598,3715.00952,566.840,
2636.52930,388.598,3715.10107,567.840,
2636.62085,388.598,3715.19263,567.840,
2636.71240,388.598,3715.28418,567.840,
2636.80396,388.598,3715.37573,567.840,
2636.89551,387.598,3715.46729,567.840,
2636.98682,387.598,3715.55884,567.840,
2637.07837,387.598,3715.65039,567.840,
2637.16992,388.598,3715.74170,567.840,
2637.26147,387.598,3715.83325,567.840,
2637.35303,388.598,3715.92480,568.840,
2637.44458,387.598,3716.01636,568.840,
2637.53613,388.598,3716.10791,568.840,
2637.62744,388.598,3716.19946,569.840,
2637.71899,389.598,3716.29102,569.840,
2637.81055,389.598,3716.38257,569.840,
2637.90210,388.598,3716.47388,569.840,
2637.99365,389.598,3716.56543,570.840,
2638.08521,389.598,3716.65698,569.840,
2638.17676,390.598,3716.74854,570.840,
2638.26831,390.598,3716.84009,570.840,
2638.35962,390.598,3716.93164,570.840,
2638.45117,389.598,3717.02319,570.840,
2638.54272,390.598,3717.11450,570.840,
2638.63428,390.598,3717.20605,570.840,
2638.72583,390.598,3717.29761,570.840,
2638.81738,391.598,3717.38916,571.840,
2638.90894,390.598,3717.48071,571.840,
2639.00049,390.598,3717.57227,571.840,
2639.09180,391.598,3717.66382,571.840,
2639.18335,390.598,3717.75537,571.840,
2639.27490,391.598,3717.84668,571.840,
2639.36646,391.598,3717.93823,571.840,
2639.45801,391.598,3718.02979,571.840,
2639.54956,391.598,3718.12134,572.840,
2639.64111,391.598,3718.21289,571.840,
2639.73242,390.598,3718.30444,571.840,
2639.82397,391.598,3718.39600,571.840,
2639.91553,391.598,3718.48755,572.840,
2640.00708,391.598,3718.57886,572.840,
2640.09863,391.598,3718.67041,573.840,
2640.19019,391.598,3718.76196,573.840,
2640.28174,391.598,3718.85352,573.840,
2640.37329,391.598,3718.94507,573.840,
2640.46460,391.598,3719.03662,573.840,
2640.55615,392.598,3719.12817,573.840,
2640.64771,391.598,3719.21948,573.840,
2640.73926,392.598,3719.31104,574.840,
2640.83081,392.598,3719.40259,573.840,
2640.92236,392.598,3719.49414,574.840,
2641.01392,392.598,3719.58569,574.840,
2641.10522,393.598,3719.67725,574.840,
2641.19678,393.598,3719.76880,574.840,
2641.28833,393.598,3719.86035,574.840,
2641.37988,393.598,3719.95166,575.840,
2641.47144,393.598,3720.04321,575.840,
2641.56299,394.598,3720.13477,575.840,
2641.65454,393.598,3720.22632,576.840,
2641.74609,393.598,3720.31787,577.840,
2641.83740,394.598,3720.40942,577.840,
2641.92896,393.598,3720.50098,577.840,
2642.02051,393.598,3720.59229,577.840,
2642.11206,394.598,3720.68384,577.840,
2642.20361,394.598,3720.77539,577.840,
2642.29517,393.598,3720.86694,577.840,
2642.38672,394.598,3720.95850,577.840,
2642.47827,394.598,3721.05005,577.840,
2642.56958,395.598,3721.14160,577.840,
2642.66113,394.598,3721.23315,578.840,
2642.75269,394.598,3721.32446,577.840,
2642.84424,395.598,3721.41602,577.840,
2642.93579,395.598,3721.50757,577.840,
2643.02734,394.598,3721.59912,578.840,
2643.11890,395.598,3721.69067,577.840,
2643.21021,395.598,3721.78223,578.840,
2643.30176,395.598,3721.87378,578.840,
2643.39331,394.598,3721.96533,578.840,
2643.48486,395.598,3722.05664,578.840,
2643.57642,395.598,3722.14819,579.840,
2643.66797,395.598,3722.23975,578.840,
2643.75952,395.598,3722.33130,578.840,
2643.85107,395.598,3722.42285,579.840,
2643.94238,395.598,3722.51440,579.840,
2644.03394,396.598,3722.60596,579.840,
2644.12549,396.598,3722.69727,579.840,
2644.21704,396.598,3722.78882,579.840,
2644.30859,396.598,3722.88037,579.840,
2644.40015,396.598,3722.97192,579.840,
2644.49170,396.598,3723.06348,580.840,
2644.58325,397.598,3723.15503,580.840,
2644.67456,396.598,3723.24658,581.840,
2644.76611,397.598,3723.33813,580.840,
2644.85767,397.598,3723.42944,580.840,
2644.94922,397.598,3723.52100,581.840,
2645.04077,397.598,3723.61255,581.840,
2645.13232,397.598,3723.70410,581.840,
2645.22388,397.598,3723.79565,581.840,
2645.31519,397.598,3723.88721,581.840,
2645.40674,398.598,3723.97876,581.840,
2645.49829,398.598,3724.07031,581.840,
2645.58984,397.598,3724.16162,582.840,
2645.68140,398.598,3724.25317,582.840,
2645.77295,398.598,3724.34473,581.840,
2645.86450,398.598,3724.43628,582.840,
2645.95605,398.598,3724.52783,582.840,
2646.04736,398.598,3724.61938,583.840,
2646.13892,398.598,3724.71094,583.840,
2646.23047,399.598,3724.80225,582.840,
2646.32202,398.598,3724.89380,583.840,
2646.41357,398.598,3724.98535,583.840,
2646.50513,399.598,3725.07690,583.840,
2646.59668,399.598,3725.16846,583.840,
2646.68799,399.598,3725.26001,583.840,
2646.77954,399.598,3725.35156,583.840,
2646.87109,399.598,3725.44312,584.840,
2646.96265,399.598,3725.53442,584.840,
2647.05420,399.598,3725.62598,583.840,
2647.14575,399.598,3725.71753,584.840,
2647.23730,399.598,3725.80908,584.840,
2647.32886,399.598,3725.90063,584.840,
2647.42017,399.598,3725.99219,584.840,
2647.51172,400.598,3726.08374,584.840,
2647.60327,400.598,3726.17505,586.840,
2647.69482,400.598,3726.26660,585.840,
2647.78638,400.598,3726.35815,585.840,
2647.87793,400.598,3726.44971,585.840,
2647.96948,400.598,3726.54126,585.840,
2648.06104,400.598,3726.63281,586.840,
2648.15234,400.598,3726.72437,586.840,
2648.24390,400.598,3726.81592,586.840,
2648.33545,401.598,3726.90723,586.840,
2648.42700,401.598,3726.99878,586.840,
2648.51855,401.598,3727.09033,586.840,
2648.61011,401.598,3727.18188,586.840,
2648.70166,401.598,3727.27344,587.840,
2648.79297,401.598,3727.36499,587.840,
2648.88452,401.598,3727.45654,587.840,
2648.97607,401.598,3727.54810,587.840,
2649.06763,401.598,3727.63940,588.840,
2649.15918,401.598,3727.73096,587.840,
2649.25073,401.598,3727.82251,588.840,
2649.34229,401.598,3727.91406,588.840,
2649.43384,401.598,3728.00562,588.840,
2649.52515,402.598,3728.09717,588.840,
2649.61670,401.598,3728.18872,588.840,
2649.70825,402.598,3728.28003,589.840,
2649.79980,401.598,3728.37158,589.840,
2649.89136,402.598,3728.46313,588.840,
2649.98291,402.598,3728.55469,589.840,
2650.07446,402.598,3728.64624,589.840,
2650.16602,402.598,3728.73779,589.840,
2650.25732,402.598,3728.82935,589.840,
2650.34888,403.598,3728.92090,589.840,
2650.44043,402.598,3729.01221,590.840,
2650.53198,403.598,3729.10376,590.840,
2650.62354,403.598,3729.19531,590.840,
2650.71509,403.598,3729.28687,590.840,
2650.80664,402.598,3729.37842,590.840,
2650.89795,403.598,3729.46997,591.840,
2650.98950,403.598,3729.56152,590.840,
2651.08105,403.598,3729.65308,591.840,
2651.17261,403.598,3729.74438,591.840,
2651.26416,403.598,3729.83594,591.840,
2651.35571,404.598,3729.92749,590.840,
2651.44727,404.598,3730.01904,591.840,
2651.53882,403.598,3730.11060,591.840,
2651.63013,403.598,3730.20215,591.840,
2651.72168,404.598,3730.29370,592.840,
2651.81323,404.598,3730.38501,592.840,
2651.90479,404.598,3730.47656,592.840,
2651.99634,404.598,3730.56812,593.840,
2652.08789,404.598,3730.65967,593.840,
2652.17944,404.598,3730.75122,593.840,
2652.27100,404.598,3730.84277,593.840,
2652.36230,404.598,3730.93433,593.840,
2652.45386,405.598,3731.02588,594.840,
2652.54541,405.598,3731.11719,593.840,
2652.63696,405.598,3731.20874,594.840,
2652.72852,405.598,3731.30029,594.840,
2652.82007,405.598,3731.39185,594.840,
2652.91162,405.598,3731.48340,594.840,
2653.00293,406.598,3731.57495,594.840,
2653.09448,405.598,3731.66650,594.840,
2653.18604,405.598,3731.75781,595.840,
2653.27759,406.598,3731.84937,595.840,
2653.36914,406.598,3731.94092,595.840,
2653.46069,405.598,3732.03247,596.840,
2653.55225,405.598,3732.12402,595.840,
2653.64380,406.598,3732.21558,595.840,
2653.73511,406.598,3732.30713,595.840,
2653.82666,406.598,3732.39868,596.840,
2653.91821,407.598,3732.48999,596.840,
2654.00977,406.598,3732.58154,596.840,
2654.10132,407.598,3732.67310,596.840,
2654.19287,407.598,3732.76465,596.840,
2654.28442,408.598,3732.85620,597.840,
2654.37573,407.598,3732.94775,597.840,
2654.46729,407.598,3733.03931,597.840,
2654.55884,407.598,3733.13086,597.840,
2654.65039,407.598,3733.22217,597.840,
2654.74194,407.598,3733.31372,597.840,
2654.83350,407.598,3733.40527,597.840,
2654.92505,407.598,3733.49683,598.840,
2655.01660,407.598,3733.58838,598.840,
2655.10791,407.598,3733.67993,598.840,
2655.19946,407.598,3733.77148,598.840,
2655.29102,408.598,3733.86279,598.840,
2655.38257,408.598,3733.95435,598.840,
2655.47412,408.598,3734.04590,599.840,
2655.56567,408.598,3734.13745,598.840,
2655.65723,408.598,3734.22900,599.840,
2655.74878,408.598,3734.32056,599.840,
2655.84009,408.598,3734.41211,599.840,
2655.93164,408.598,3734.50366,599.840,
2656.02319,408.598,3734.59497,599.840,
2656.11475,408.598,3734.68652,599.840,
2656.20630,409.598,3734.77808,600.840,
2656.29785,409.598,3734.86963,600.840,
2656.38940,409.598,3734.96118,600.840,
2656.48071,409.598,3735.05273,600.840,
2656.57227,409.598,3735.14429,600.840,
2656.66382,409.598,3735.23584,601.840,
2656.75537,409.598,3735.32715,601.840,
2656.84692,409.598,3735.41870,601.840,
2656.93848,410.598,3735.51025,601.840,
2657.03003,410.598,3735.60181,601.840,
2657.12158,409.598,3735.69336,601.840,
2657.21289,410.598,3735.78491,602.840,
2657.30444,410.598,3735.87646,601.840,
2657.39600,410.598,3735.96777,602.840,
2657.48755,410.598,3736.05933,602.840,
2657.57910,410.598,3736.15088,602.840,
2657.67065,410.598,3736.24243,602.840,
2657.76221,410.598,3736.33398,602.840,
2657.85376,410.598,3736.42554,603.840,
2657.94507,411.598,3736.51709,603.840,
2658.03662,410.598,3736.60864,603.840,
2658.12817,410.598,3736.69995,603.840,
2658.21973,411.598,3736.79150,603.840,
2658.31128,411.598,3736.88306,603.840,
2658.40283,411.598,3736.97461,604.840,
2658.49438,411.598,3737.06616,604.840,
2658.58569,411.598,3737.15771,603.840,
2658.67725,412.598,3737.24927,604.840,
2658.76880,412.598,3737.34082,604.840,
2658.86035,412.598,3737.43213,604.840,
2658.95190,412.598,3737.52368,604.840,
2659.04346,413.598,3737.61523,605.840,
2659.13501,413.598,3737.70679,605.840,
2659.22656,413.598,3737.79834,605.840,
2659.31787,412.598,3737.88989,605.840,
2659.40942,412.598,3737.98145,606.840,
2659.50098,413.598,3738.07275,606.840,
2659.59253,412.598,3738.16431,605.840,
2659.68408,413.598,3738.25586,606.840,
2659.77563,413.598,3738.34741,606.840,
2659.86719,412.598,3738.43896,605.840,
2659.95850,413.598,3738.53052,606.840,
2660.05005,413.598,3738.62207,606.840,
2660.14160,414.598,3738.71362,606.840,
2660.23315,413.598,3738.80493,606.840,
2660.32471,413.598,3738.89648,607.840,
2660.41626,413.598,3738.98804,607.840,
2660.50781,413.598,3739.07959,607.840,
2660.59937,413.598,3739.17114,607.840,
2660.69067,414.598,3739.26270,607.840,
2660.78223,413.598,3739.35425,608.840,
2660.87378,414.598,3739.44556,608.840,
2660.96533,415.598,3739.53711,608.840,
2661.05688,415.598,3739.62866,608.840,
2661.14844,416.598,3739.72021,608.840,
2661.23999,417.598,3739.81177,608.840,
2661.33154,417.598,3739.90332,608.840,
2661.42285,417.598,3739.99487,608.840,
2661.51440,418.598,3740.08643,609.840,
2661.60596,418.598,3740.17773,608.840,
2661.69751,418.598,3740.26929,609.840,
2661.78906,418.598,3740.36084,609.840,
2661.88062,418.598,3740.45239,610.840,
2661.97217,418.598,3740.54395,610.840,
2662.06348,417.598,3740.63550,610.840,
2662.15503,417.598,3740.72705,610.840,
2662.24658,417.598,3740.81860,611.840,
2662.33813,417.598,3740.90991,611.840,
2662.42969,417.598,3741.00146,611.840,
2662.52124,417.598,3741.09302,611.840,
2662.61279,416.598,3741.18457,611.840,
2662.70435,416.598,3741.27612,611.840,
2662.79565,416.598,3741.36768,611.840,
2662.88721,416.598,3741.45923,611.840,
2662.97876,416.598,3741.55054,611.840,
2663.07031,417.598,3741.64209,611.840,
2663.16187,416.598,3741.73364,611.840,
2663.25342,416.598,3741.82520,611.840,
2663.34497,416.598,3741.91675,612.840,
2663.43652,416.598,3742.00830,612.840,
2663.52783,416.598,3742.09985,611.840,
2663.61938,417.598,3742.19141,611.840,
2663.71094,417.598,3742.28271,613.840,
2663.80249,416.598,3742.37427,612.840,
2663.89404,417.598,3742.46582,613.840,
2663.98560,417.598,3742.55737,613.840,
2664.07715,417.598,3742.64893,613.840,
2664.16846,417.598,3742.74048,613.840,
2664.26001,416.598,3742.83203,614.840,
2664.35156,417.598,3742.92358,614.840,
2664.44312,417.598,3743.01489,614.840,
2664.53467,417.598,3743.10645,614.840,
2664.62622,418.598,3743.19800,614.840,
2664.71777,417.598,3743.28955,614.840,
2664.80933,418.598,3743.38110,615.840,
2664.90063,418.598,3743.47266,615.840,
2664.99219,418.598,3743.56421,615.840,
2665.08374,418.598,3743.65552,615.840,
2665.17529,419.598,3743.74707,616.840,
2665.26685,419.598,3743.83862,615.840,
2665.35840,418.598,3743.93018,616.840,
2665.44995,419.598,3744.02173,616.840,
2665.54126,419.598,3744.11328,616.840,
2665.63281,419.598,3744.20483,616.840,
2665.72437,419.598,3744.29639,617.840,
2665.81592,419.598,3744.38770,616.840,
2665.90747,419.598,3744.47925,616.840,
2665.99902,419.598,3744.57080,616.840,
2666.09058,419.598,3744.66235,617.840,
2666.18213,420.598,3744.75391,616.840,
2666.27344,420.598,3744.84546,617.840,
2666.36499,420.598,3744.93701,617.840,
2666.45654,420.598,3745.02832,617.840,
2666.54810,419.598,3745.11987,617.840,
2666.63965,420.598,3745.21143,618.840,
2666.73120,420.598,3745.30298,618.840,
2666.82275,420.598,3745.39453,618.840,
2666.91431,420.598,3745.48608,618.840,
2667.00562,420.598,3745.57764,618.840,
2667.09717,421.598,3745.66919,618.840,
2667.18872,421.598,3745.76050,619.840,
2667.28027,420.598,3745.85205,619.840,
2667.37183,420.598,3745.94360,619.840,
2667.46338,421.598,3746.03516,619.840,
2667.55493,421.598,3746.12671,619.840,
2667.64624,421.598,3746.21826,619.840,
2667.73779,421.598,3746.30981,619.840,
2667.82935,421.598,3746.40137,620.840,
2667.92090,421.598,3746.49268,620.840,
2668.01245,421.598,3746.58423,620.840,
2668.10400,421.598,3746.67578,621.840,
2668.19556,422.598,3746.76733,620.840,
2668.28711,422.598,3746.85889,621.840,
2668.37842,422.598,3746.95044,620.840,
2668.46997,422.598,3747.04199,621.840,
2668.56152,422.598,3747.13330,621.840,
2668.65308,422.598,3747.22485,621.840,
2668.74463,422.598,3747.31641,622.840,
2668.83618,422.598,3747.40796,622.840,
2668.92773,423.598,3747.49951,622.840,
2669.01929,422.598,3747.59106,622.840,
2669.11060,423.598,3747.68262,622.840,
2669.20215,423.598,3747.77417,622.840,
2669.29370,423.598,3747.86548,623.840,
2669.38525,423.598,3747.95703,623.840,
2669.47681,423.598,3748.04858,623.840,
2669.56836,423.598,3748.14014,623.840,
2669.65991,423.598,3748.23169,623.840,
2669.75122,423.598,3748.32324,623.840,
2669.84277,423.598,3748.41479,623.840,
2669.93433,423.598,3748.50635,623.840,
2670.02588,423.598,3748.59766,624.840,
2670.11743,423.598,3748.68921,624.840,
2670.20898,423.598,3748.78076,624.840,
2670.30054,424.598,3748.87231,624.840,
2670.39209,424.598,3748.96387,624.840,
2670.48340,424.598,3749.05542,624.840,
2670.57495,424.598,3749.14697,625.840,
2670.66650,424.598,3749.23828,625.840,
2670.75806,424.598,3749.32983,625.840,
2670.84961,424.598,3749.42139,625.840,
2670.94116,425.598,3749.51294,625.840,
2671.03271,425.598,3749.60449,626.840,
2671.12427,424.598,3749.69604,626.840,
2671.21558,425.598,3749.78760,626.840,
2671.30713,425.598,3749.87915,626.840,
2671.39868,425.598,3749.97046,626.840,
2671.49023,425.598,3750.06201,627.840,
2671.58179,425.598,3750.15356,627.840,
2671.67334,425.598,3750.24512,627.840,
2671.76489,425.598,3750.33667,627.840,
2671.85620,426.598,3750.42822,627.840,
2671.94775,425.598,3750.51978,627.840,
2672.03931,426.598,3750.61108,627.840,
2672.13086,425.598,3750.70264,628.840,
2672.22241,426.598,3750.79419,628.840,
2672.31396,426.598,3750.88574,628.840,
2672.40552,426.598,3750.97729,628.840,
2672.49707,426.598,3751.06885,629.840,
2672.58838,426.598,3751.16040,629.840,
2672.67993,426.598,3751.25195,628.840,
2672.77148,426.598,3751.34326,629.840,
2672.86304,427.598,3751.43481,629.840,
2672.95459,426.598,3751.52637,629.840,
2673.04614,427.598,3751.61792,629.840,
2673.13770,427.598,3751.70947,630.840,
2673.22900,427.598,3751.80103,630.840,
2673.32056,428.598,3751.89258,630.840,
2673.41211,427.598,3751.98413,630.840,
2673.50366,427.598,3752.07544,630.840,
2673.59521,427.598,3752.16699,630.840,
2673.68677,428.598,3752.25854,631.840,
2673.77832,428.598,3752.35010,631.840,
2673.86987,427.598,3752.44165,631.840,
2673.96118,428.598,3752.53320,631.840,
2674.05273,428.598,3752.62476,631.840,
2674.14429,428.598,3752.71606,631.840,
2674.23584,428.598,3752.80762,631.840,
2674.32739,429.598,3752.89917,632.840,
2674.41895,428.598,3752.99072,632.840,
2674.51050,428.598,3753.08228,632.840,
2674.60205,429.598,3753.17383,633.840,
2674.69336,429.598,3753.26538,632.840,
2674.78491,429.598,3753.35693,632.840,
2674.87646,429.598,3753.44824,633.840,
2674.96802,429.598,3753.53979,633.840,
2675.05957,429.598,3753.63135,632.840,
2675.15112,429.598,3753.72290,633.840,
2675.24268,429.598,3753.81445,633.840,
2675.33398,429.598,3753.90601,633.840,
2675.42554,430.598,3753.99756,635.840,
2675.51709,430.598,3754.08911,634.840,
2675.60864,430.598,3754.18042,633.840,
2675.70020,429.598,3754.27197,634.840,
2675.79175,430.598,3754.36353,634.840,
2675.88330,430.598,3754.45508,634.840,
2675.97485,429.598,3754.54663,634.840,
2676.06616,430.598,3754.63818,635.840,
2676.15771,430.598,3754.72974,635.840,
2676.24927,431.598,3754.82104,635.840,
2676.34082,430.598,3754.91260,636.840,
2676.43237,430.598,3755.00415,635.840,
2676.52393,431.598,3755.09570,635.840,
2676.61548,430.598,3755.18726,636.840,
2676.70703,431.598,3755.27881,636.840,
2676.79834,431.598,3755.37036,636.840,
2676.88989,431.598,3755.46191,637.840,
2676.98145,431.598,3755.55322,637.840,
2677.07300,431.598,3755.64478,637.840,
2677.16455,431.598,3755.73633,636.840,
2677.25610,431.598,3755.82788,637.840,
2677.34766,431.598,3755.91943,637.840,
2677.43896,432.598,3756.01099,637.840,
2677.53052,432.598,3756.10254,637.840,
2677.62207,431.598,3756.19409,638.840,
2677.71362,433.598,3756.28540,637.840,
2677.80518,432.598,3756.37695,637.840,
2677.89673,432.598,3756.46851,638.840,
2677.98828,432.598,3756.56006,638.840,
2678.07983,433.598,3756.65161,638.840,
2678.17114,432.598,3756.74316,639.840,
2678.26270,432.598,3756.83472,639.840,
2678.35425,433.598,3756.92603,639.840,
2678.44580,433.598,3757.01758,639.840,
2678.53735,432.598,3757.10913,639.840,
2678.62891,432.598,3757.20068,639.840,
2678.72046,432.598,3757.29224,639.840,
2678.81177,433.598,3757.38379,639.840,
2678.90332,433.598,3757.47534,640.840,
2678.99487,433.598,3757.56689,640.840,
2679.08643,433.598,3757.65820,640.840,
2679.17798,434.598,3757.74976,640.840,
2679.26953,434.598,3757.84131,640.840,
2679.36108,434.598,3757.93286,641.840,
2679.45264,434.598,3758.02441,641.840,
2679.54395,434.598,3758.11597,641.840,
2679.63550,434.598,3758.20752,641.840,
2679.72705,434.598,3758.29883,641.840,
2679.81860,434.598,3758.39038,642.840,
2679.91016,434.598,3758.48193,641.840,
2680.00171,434.598,3758.57349,642.840,
2680.09326,434.598,3758.66504,642.840,
2680.18481,435.598,3758.75659,642.840,
2680.27612,434.598,3758.84814,642.840,
2680.36768,435.598,3758.93970,643.840,
2680.45923,435.598,3759.03101,643.840,
2680.55078,435.598,3759.12256,643.840,
2680.64233,436.598,3759.21411,643.840,
2680.73389,435.598,3759.30566,643.840,
2680.82544,435.598,3759.39722,643.840,
2680.91675,436.598,3759.48877,644.840,
2681.00830,436.598,3759.58032,644.840,
2681.09985,436.598,3759.67188,644.840,
2681.19141,436.598,3759.76318,645.840,
2681.28296,437.598,3759.85474,646.840,
2681.37451,437.598,3759.94629,645.840,
2681.46606,437.598,3760.03784,645.840,
2681.55762,438.598,3760.12939,645.840,
2681.64893,439.598,3760.22095,645.840,
2681.74048,439.598,3760.31250,645.840,
2681.83203,439.598,3760.40381,646.840,
2681.92358,440.598,3760.49536,646.840,
2682.01514,439.598,3760.58691,646.840,
2682.10669,439.598,3760.67847,646.840,
2682.19824,439.598,3760.77002,646.840,
2682.28979,440.598,3760.86157,646.840,
2682.38110,439.598,3760.95313,646.840,
2682.47266,439.598,3761.04468,646.840,
2682.56421,439.598,3761.13599,647.840,
2682.65576,439.598,3761.22754,647.840,
2682.74731,438.598,3761.31909,648.840,
2682.83887,439.598,3761.41064,647.840,
2682.93042,438.598,3761.50220,647.840,
2683.02173,438.598,3761.59375,648.840,
2683.11328,439.598,3761.68530,649.840,
2683.20483,439.598,3761.77686,649.840,
2683.29639,438.598,3761.86816,649.840,
2683.38794,438.598,3761.95972,650.840,
2683.47949,437.598,3762.05127,650.840,
2683.57104,437.598,3762.14282,650.840,
2683.66260,435.598,3762.23438,650.840,
2683.75391,435.598,3762.32593,651.840,
2683.84546,435.598,3762.41748,650.840,
2683.93701,435.598,3762.50879,651.840,
2684.02856,435.598,3762.60034,651.840,
2684.12012,435.598,3762.69189,650.840,
2684.21167,435.598,3762.78345,652.840,
2684.30322,436.598,3762.87500,651.840,
2684.39453,436.598,3762.96655,651.840,
2684.48608,437.598,3763.05811,651.840,
2684.57764,436.598,3763.14966,651.840,
2684.66919,437.598,3763.24097,651.840,
2684.76074,438.598,3763.33252,651.840,
2684.85229,438.598,3763.42407,651.840,
2684.94385,438.598,3763.51563,651.840,
2685.03540,440.598,3763.60718,651.840,
2685.12671,439.598,3763.69873,651.840,
2685.21826,440.598,3763.79028,651.840,
2685.30981,440.598,3763.88159,651.840,
2685.40137,441.598,3763.97314,651.840,
2685.49292,441.598,3764.06470,651.840,
2685.58447,440.598,3764.15625,652.840,
2685.67603,441.598,3764.24780,652.840,
2685.76758,441.598,3764.33936,652.840,
2685.85889,441.598,3764.43091,653.840,
2685.95044,441.598,3764.52246,652.840,
2686.04199,441.598,3764.61377,653.840,
2686.13354,441.598,3764.70532,654.840,
2686.22510,442.598,3764.79688,653.840,
2686.31665,442.598,3764.88843,653.840,
2686.40820,442.598,3764.97998,654.840,
2686.49951,442.598,3765.07153,653.840,
2686.59106,442.598,3765.16309,653.840,
2686.68262,442.598,3765.25464,654.840,
2686.77417,442.598,3765.34595,654.840,
2686.86572,442.598,3765.43750,654.840,
2686.95728,443.598,3765.52905,654.840,
2687.04883,442.598,3765.62061,655.840,
2687.14038,442.598,3765.71216,656.840,
2687.23169,443.598,3765.80371,655.840,
2687.32324,443.598,3765.89526,656.840,
2687.41479,443.598,3765.98657,656.840,
2687.50635,443.598,3766.07813,655.840,
2687.59790,443.598,3766.16968,655.840,
2687.68945,443.598,3766.26123,656.840,
2687.78101,443.598,3766.35278,656.840,
2687.87256,443.598,3766.44434,656.840,
2687.96387,444.598,3766.53589,656.840,
2688.05542,444.598,3766.62744,656.840,
2688.14697,444.598,3766.71875,656.840,
2688.23853,444.598,3766.81030,657.840,
2688.33008,444.598,3766.90186,657.840,
2688.42163,444.598,3766.99341,657.840,
2688.51318,444.598,3767.08496,657.840,
2688.60449,444.598,3767.17651,658.840,
2688.69604,444.598,3767.26807,658.840,
2688.78760,444.598,3767.35962,658.840,
2688.87915,444.598,3767.45093,658.840,
2688.97070,445.598,3767.54248,659.840,
2689.06226,445.598,3767.63403,659.840,
2689.15381,445.598,3767.72559,659.840,
2689.24536,444.598,3767.81714,659.840,
2689.33667,445.598,3767.90869,659.840,
2689.42822,445.598,3768.00024,659.840,
2689.51978,445.598,3768.09155,659.840,
2689.61133,445.598,3768.18311,659.840,
2689.70288,445.598,3768.27466,659.840,
2689.79443,445.598,3768.36621,660.840,
2689.88599,446.598,3768.45776,659.840,
2689.97754,446.598,3768.54932,660.840,
2690.06885,445.598,3768.64087,660.840,
2690.16040,446.598,3768.73242,660.840,
2690.25195,446.598,3768.82373,660.840,
2690.34351,446.598,3768.91528,660.840,
2690.43506,446.598,3769.00684,661.840,
2690.52661,446.598,3769.09839,661.840,
2690.61816,446.598,3769.18994,661.840,
2690.70947,446.598,3769.28149,662.840,
2690.80103,447.598,3769.37305,662.840,
2690.89258,447.598,3769.46436,661.840,
2690.98413,447.598,3769.55591,662.840,
2691.07568,447.598,3769.64746,662.840,
2691.16724,447.598,3769.73901,662.840,
2691.25879,447.598,3769.83057,662.840,
2691.35034,448.598,3769.92212,662.840,
2691.44165,448.598,3770.01367,663.840,
2691.53320,448.598,3770.10522,663.840,
2691.62476,447.598,3770.19653,663.840,
2691.71631,448.598,3770.28809,663.840,
2691.80786,449.598,3770.37964,663.840,
2691.89941,448.598,3770.47119,663.840,
2691.99097,448.598,3770.56274,664.840,
2692.08228,448.598,3770.65430,664.840,
2692.17383,448.598,3770.74585,664.840,
2692.26538,448.598,3770.83740,664.840,
2692.35693,450.598,3770.92871,664.840,
2692.44849,448.598,3771.02026,664.840,
2692.54004,449.598,3771.11182,665.840,
2692.63159,449.598,3771.20337,665.840,
2692.72314,449.598,3771.29492,665.840,
2692.81445,449.598,3771.38647,665.840,
2692.90601,449.598,3771.47803,665.840,
2692.99756,449.598,3771.56934,666.840,
2693.08911,449.598,3771.66089,666.840,
2693.18066,449.598,3771.75244,666.840,
2693.27222,450.598,3771.84399,666.840,
2693.36377,450.598,3771.93555,667.840,
2693.45532,450.598,3772.02710,667.840,
2693.54663,450.598,3772.11865,667.840,
2693.63818,450.598,3772.21021,667.840,
2693.72974,450.598,3772.30151,667.840,
2693.82129,451.598,3772.39307,667.840,
2693.91284,451.598,3772.48462,667.840,
2694.00439,451.598,3772.57617,668.840,
2694.09595,450.598,3772.66772,668.840,
2694.18726,450.598,3772.75928,668.840,
2694.27881,450.598,3772.85083,668.840,
2694.37036,451.598,3772.94238,668.840,
2694.46191,451.598,3773.03369,669.840,
2694.55347,451.598,3773.12524,669.840,
2694.64502,451.598,3773.21680,669.840,
2694.73657,451.598,3773.30835,669.840,
2694.82813,452.598,3773.39990,669.840,
2694.91943,452.598,3773.49146,670.840,
2695.01099,452.598,3773.58301,669.840,
2695.10254,452.598,3773.67432,670.840,
2695.19409,451.598,3773.76587,670.840,
2695.28564,452.598,3773.85742,670.840,
2695.37720,452.598,3773.94897,670.840,
2695.46875,452.598,3774.04053,670.840,
2695.56030,452.598,3774.13208,671.840,
2695.65161,452.598,3774.22363,671.840,
2695.74316,452.598,3774.31519,671.840,
2695.83472,452.598,3774.40649,671.840,
2695.92627,452.598,3774.49805,671.840,
2696.01782,453.598,3774.58960,671.840,
2696.10938,452.598,3774.68115,671.840,
2696.20093,453.598,3774.77271,671.840,
2696.29224,452.598,3774.86426,672.840,
2696.38379,453.598,3774.95581,672.840,
2696.47534,453.598,3775.04736,672.840,
2696.56689,453.598,3775.13867,673.840,
2696.65845,453.598,3775.23022,672.840,
2696.75000,454.598,3775.32178,673.840,
2696.84155,454.598,3775.41333,673.840,
2696.93311,453.598,3775.50488,673.840,
2697.02441,454.598,3775.59644,673.840,
2697.11597,454.598,3775.68799,673.840,
2697.20752,453.598,3775.77930,673.840,
2697.29907,454.598,3775.87085,673.840,
2697.39063,454.598,3775.96240,674.840,
2697.48218,454.598,3776.05396,674.840,
2697.57373,454.598,3776.14551,674.840,
2697.66504,455.598,3776.23706,674.840,
2697.75659,455.598,3776.32861,674.840,
2697.84814,454.598,3776.42017,674.840,
2697.93970,455.598,3776.51147,675.840,
2698.03125,455.598,3776.60303,675.840,
2698.12280,455.598,3776.69458,674.840,
2698.21436,456.598,3776.78613,675.840,
2698.30591,455.598,3776.87769,676.840,
2698.39722,455.598,3776.96924,675.840,
2698.48877,455.598,3777.06079,676.840,
2698.58032,456.598,3777.15210,676.840,
2698.67188,456.598,3777.24365,676.840,
2698.76343,456.598,3777.33521,676.840,
2698.85498,456.598,3777.42676,677.840,
2698.94653,456.598,3777.51831,677.840,
2699.03809,456.598,3777.60986,677.840,
2699.12939,456.598,3777.70142,677.840,
2699.22095,456.598,3777.79297,677.840,
2699.31250,456.598,3777.88428,678.840,
2699.40405,456.598,3777.97583,677.840,
2699.49561,456.598,3778.06738,678.840,
2699.58716,456.598,3778.15894,678.840,
2699.67871,457.598,3778.25049,678.840,
2699.77002,457.598,3778.34204,678.840,
2699.86157,457.598,3778.43359,679.840,
2699.95313,457.598,3778.52515,678.840,
2700.04468,457.598,3778.61646,679.840,
2700.13623,457.598,3778.70801,680.840,
2700.22778,457.598,3778.79956,679.840,
2700.31934,458.598,3778.89111,679.840,
2700.41089,458.598,3778.98267,680.840,
2700.50220,457.598,3779.07422,680.840,
2700.59375,458.598,3779.16577,680.840,
2700.68530,458.598,3779.25708,680.840,
2700.77686,458.598,3779.34863,680.840,
2700.86841,458.598,3779.44019,680.840,
2700.95996,459.598,3779.53174,680.840,
2701.05151,459.598,3779.62329,681.840,
2701.14307,459.598,3779.71484,681.840,
2701.23438,459.598,3779.80640,681.840,
2701.32593,459.598,3779.89795,681.840,
2701.41748,458.598,3779.98926,682.840,
2701.50903,459.598,3780.08081,682.840,
2701.60059,459.598,3780.17236,682.840,
2701.69214,459.598,3780.26392,682.840,
2701.78369,459.598,3780.35547,683.840,
2701.87500,459.598,3780.44702,682.840,
2701.96655,459.598,3780.53857,683.840,
2702.05811,459.598,3780.63013,683.840,
2702.14966,459.598,3780.72144,683.840,
2702.24121,459.598,3780.81299,683.840,
2702.33276,460.598,3780.90454,684.840,
2702.42432,460.598,3780.99609,684.840,
2702.51587,460.598,3781.08765,684.840,
2702.60718,460.598,3781.17920,684.840,
2702.69873,460.598,3781.27075,684.840,
2702.79028,460.598,3781.36206,684.840,
2702.88184,460.598,3781.45361,684.840,
2702.97339,461.598,3781.54517,685.840,
2703.06494,461.598,3781.63672,685.840,
2703.15649,461.598,3781.72827,684.840,
2703.24780,461.598,3781.81982,685.840,
2703.33936,462.598,3781.91138,685.840,
2703.43091,462.598,3782.00293,685.840,
2703.52246,461.598,3782.09424,685.840,
2703.61401,462.598,3782.18579,685.840,
2703.70557,462.598,3782.27734,686.840,
2703.79712,462.598,3782.36890,686.840,
2703.88867,462.598,3782.46045,686.840,
2703.97998,462.598,3782.55200,686.840,
2704.07153,463.598,3782.64355,686.840,
2704.16309,462.598,3782.73486,687.840,
2704.25464,462.598,3782.82642,687.840,
2704.34619,461.598,3782.91797,687.840,
2704.43774,461.598,3783.00952,687.840,
2704.52930,461.598,3783.10107,687.840,
2704.62085,461.598,3783.19263,687.840,
2704.71216,461.598,3783.28418,688.840,
2704.80371,461.598,3783.37573,687.840,
2704.89526,461.598,3783.46704,688.840,
2704.98682,461.598,3783.55859,688.840,
2705.07837,461.598,3783.65015,688.840,
2705.16992,462.598,3783.74170,688.840,
2705.26147,462.598,3783.83325,688.840,
2705.35278,462.598,3783.92480,689.840,
2705.44434,463.598,3784.01636,689.840,
2705.53589,463.598,3784.10791,689.840,
2705.62744,463.598,3784.19922,689.840,
2705.71899,463.598,3784.29077,689.840,
2705.81055,464.598,3784.38232,690.840,
2705.90210,464.598,3784.47388,689.840,
2705.99365,464.598,3784.56543,690.840,
2706.08496,464.598,3784.65698,690.840,
2706.17651,464.598,3784.74854,691.840,
2706.26807,464.598,3784.83984,691.840,
2706.35962,464.598,3784.93140,690.840,
2706.45117,465.598,3785.02295,691.840,
2706.54272,465.598,3785.11450,691.840,
2706.63428,465.598,3785.20605,691.840,
2706.72583,465.598,3785.29761,691.840,
2706.81714,465.598,3785.38916,691.840,
2706.90869,465.598,3785.48071,691.840,
2707.00024,466.598,3785.57202,691.840,
2707.09180,466.598,3785.66357,692.840,
2707.18335,466.598,3785.75513,692.840,
2707.27490,466.598,3785.84668,691.840,
2707.36646,467.598,3785.93823,692.840,
2707.45776,467.598,3786.02979,692.840,
2707.54932,466.598,3786.12134,692.840,
2707.64087,467.598,3786.21289,693.840,
2707.73242,467.598,3786.30420,693.840,
2707.82397,466.598,3786.39575,693.840,
2707.91553,467.598,3786.48730,693.840,
2708.00708,467.598,3786.57886,693.840,
2708.09863,467.598,3786.67041,693.840,
2708.18994,467.598,3786.76196,694.840,
2708.28149,467.598,3786.85352,693.840,
2708.37305,467.598,3786.94482,694.840,
2708.46460,467.598,3787.03638,694.840,
2708.55615,467.598,3787.12793,694.840,
2708.64771,467.598,3787.21948,695.840,
2708.73926,467.598,3787.31104,695.840,
2708.83081,468.598,3787.40259,694.840,
2708.92212,468.598,3787.49414,695.840,
2709.01367,468.598,3787.58569,695.840,
2709.10522,468.598,3787.67700,695.840,
2709.19678,468.598,3787.76855,695.840,
2709.28833,468.598,3787.86011,696.840,
2709.37988,468.598,3787.95166,695.840,
2709.47144,468.598,3788.04321,696.840,
2709.56274,468.598,3788.13477,696.840,
2709.65430,468.598,3788.22632,696.840,
2709.74585,468.598,3788.31763,697.840,
2709.83740,469.598,3788.40918,696.840,
2709.92896,469.598,3788.50073,697.840,
2710.02051,469.598,3788.59229,697.840,
2710.11206,469.598,3788.68384,697.840,
2710.20361,469.598,3788.77539,697.840,
2710.29492,469.598,3788.86694,697.840,
2710.38647,469.598,3788.95850,698.840,
2710.47803,469.598,3789.04980,698.840,
2710.56958,469.598,3789.14136,699.840,
2710.66113,469.598,3789.23291,698.840,
2710.75269,470.598,3789.32446,699.840,
2710.84424,469.598,3789.41602,699.840,
2710.93555,470.598,3789.50757,699.840,
2711.02710,470.598,3789.59912,699.840,
2711.11865,470.598,3789.69067,699.840,
2711.21021,470.598,3789.78198,699.840,
2711.30176,471.598,3789.87354,700.840,
2711.39331,471.598,3789.96509,700.840,
2711.48486,470.598,3790.05664,699.840,
2711.57642,471.598,3790.14819,700.840,
2711.66772,470.598,3790.23975,700.840,
2711.75928,471.598,3790.33130,700.840,
2711.85083,471.598,3790.42261,700.840,
2711.94238,471.598,3790.51416,700.840,
2712.03394,471.598,3790.60571,701.840,
2712.12549,471.598,3790.69727,701.840,
2712.21704,471.598,3790.78882,701.840,
2712.30859,471.598,3790.88037,702.840,
2712.39990,472.598,3790.97192,702.840,
2712.49146,472.598,3791.06348,702.840,
2712.58301,472.598,3791.15479,702.840,
2712.67456,472.598,3791.24634,702.840,
2712.76611,472.598,3791.33789,702.840,
2712.85767,473.598,3791.42944,702.840,
2712.94922,472.598,3791.52100,703.840,
2713.04053,472.598,3791.61255,703.840,
2713.13208,473.598,3791.70410,703.840,
2713.22363,473.598,3791.79565,703.840,
2713.31519,473.598,3791.88696,703.840,
2713.40674,473.598,3791.97852,703.840,
2713.49829,473.598,3792.07007,705.840,
2713.58984,473.598,3792.16162,704.840,
2713.68140,473.598,3792.25317,704.840,
2713.77271,473.598,3792.34473,705.840,
2713.86426,473.598,3792.43628,705.840,
2713.95581,473.598,3792.52759,704.840,
2714.04736,474.598,3792.61914,705.840,
2714.13892,473.598,3792.71069,705.840,
2714.23047,473.598,3792.80225,705.840,
2714.32202,474.598,3792.89380,705.840,
2714.41357,474.598,3792.98535,705.840,
2714.50488,474.598,3793.07690,706.840,
2714.59644,474.598,3793.16846,706.840,
2714.68799,474.598,3793.25977,706.840,
2714.77954,474.598,3793.35132,706.840,
2714.87109,475.598,3793.44287,706.840,
2714.96265,475.598,3793.53442,707.840,
2715.05420,475.598,3793.62598,707.840,
2715.14551,475.598,3793.71753,707.840,
2715.23706,475.598,3793.80908,707.840,
2715.32861,475.598,3793.90039,707.840,
2715.42017,475.598,3793.99194,707.840,
2715.51172,475.598,3794.08350,707.840,
2715.60327,476.598,3794.17505,708.840,
2715.69482,476.598,3794.26660,708.840,
2715.78638,476.598,3794.35815,707.840,
2715.87769,476.598,3794.44971,708.840,
2715.96924,477.598,3794.54126,708.840,
2716.06079,476.598,3794.63257,708.840,
2716.15234,476.598,3794.72412,708.840,
2716.24390,476.598,3794.81567,708.840,
2716.33545,476.598,3794.90723,709.840,
2716.42700,476.598,3794.99878,709.840,
2716.51831,476.598,3795.09033,709.840,
2716.60986,476.598,3795.18188,709.840,
2716.70142,477.598,3795.27344,709.840,
2716.79297,477.598,3795.36475,710.840,
2716.88452,477.598,3795.45630,710.840,
2716.97607,477.598,3795.54785,710.840,
2717.06763,477.598,3795.63940,710.840,
2717.15918,477.598,3795.73096,710.840,
2717.25049,477.598,3795.82251,711.840,
2717.34204,478.598,3795.91406,711.840,
2717.43359,477.598,3796.00537,711.840,
2717.52515,478.598,3796.09692,711.840,
2717.61670,478.598,3796.18848,711.840,
2717.70825,478.598,3796.28003,711.840,
2717.79980,478.598,3796.37158,711.840,
2717.89136,478.598,3796.46313,713.840,
2717.98267,478.598,3796.55469,712.840,
2718.07422,479.598,3796.64624,712.840,
2718.16577,478.598,3796.73755,712.840,
2718.25732,479.598,3796.82910,712.840,
2718.34888,478.598,3796.92065,713.840,
2718.44043,478.598,3797.01221,714.840,
2718.53198,479.598,3797.10376,713.840,
2718.62329,479.598,3797.19531,714.840,
2718.71484,480.598,3797.28687,714.840,
2718.80640,479.598,3797.37842,713.840,
2718.89795,479.598,3797.46973,714.840,
2718.98950,480.598,3797.56128,714.840,
2719.08105,479.598,3797.65283,714.840,
2719.17261,479.598,3797.74438,714.840,
2719.26416,480.598,3797.83594,714.840,
2719.35547,480.598,3797.92749,715.840,
2719.44702,480.598,3798.01904,715.840,
2719.53857,480.598,3798.11035,715.840,
2719.63013,480.598,3798.20190,715.840,
2719.72168,480.598,3798.29346,715.840,
2719.81323,480.598,3798.38501,715.840,
2719.90479,480.598,3798.47656,716.840,
2719.99634,480.598,3798.56812,716.840,
2720.08765,481.598,3798.65967,715.840,
2720.17920,481.598,3798.75122,716.840,
2720.27075,481.598,3798.84253,716.840,
2720.36230,481.598,3798.93408,716.840,
2720.45386,481.598,3799.02563,716.840,
2720.54541,481.598,3799.11719,717.840,
2720.63696,481.598,3799.20874,716.840,
2720.72827,482.598,3799.30029,717.840,
2720.81982,482.598,3799.39185,718.840,
2720.91138,481.598,3799.48340,717.840,
2721.00293,482.598,3799.57471,718.840,
2721.09448,482.598,3799.66626,718.840,
2721.18604,482.598,3799.75781,718.840,
2721.27759,482.598,3799.84937,718.840,
2721.36914,482.598,3799.94092,719.840,
2721.46045,482.598,3800.03247,718.840,
2721.55200,482.598,3800.12402,719.840,
2721.64355,483.598,3800.21533,719.840,
2721.73511,483.598,3800.30688,719.840,
2721.82666,482.598,3800.39844,719.840,
2721.91821,483.598,3800.48999,719.840,
2722.00977,483.598,3800.58154,719.840,
2722.10107,483.598,3800.67310,720.840,
2722.19263,483.598,3800.76465,720.840,
2722.28418,483.598,3800.85620,720.840,
2722.37573,483.598,3800.94751,720.840,
2722.46729,483.598,3801.03906,720.840,
2722.55884,483.598,3801.13062,721.840,
2722.65039,484.598,3801.22217,721.840,
2722.74194,483.598,3801.31372,721.840,
2722.83325,484.598,3801.40527,721.840,
2722.92480,484.598,3801.49683,722.840,
2723.01636,484.598,3801.58813,722.840,
2723.10791,485.598,3801.67969,722.840,
2723.19946,485.598,3801.77124,722.840,
2723.29102,484.598,3801.86279,723.840,
2723.38257,485.598,3801.95435,723.840,
2723.47412,485.598,3802.04590,722.840,
2723.56543,485.598,3802.13745,723.840,
2723.65698,485.598,3802.22900,723.840,
2723.74854,485.598,3802.32031,723.840,
2723.84009,485.598,3802.41187,723.840,
2723.93164,486.598,3802.50342,723.840,
2724.02319,485.598,3802.59497,723.840,
2724.11475,486.598,3802.68652,724.840,
2724.20605,485.598,3802.77808,724.840,
2724.29761,486.598,3802.86963,724.840,
2724.38916,486.598,3802.96118,724.840,
2724.48071,486.598,3803.05249,725.840,
2724.57227,486.598,3803.14404,724.840,
2724.66382,486.598,3803.23560,724.840,
2724.75537,487.598,3803.32715,724.840,
2724.84692,487.598,3803.41870,724.840,
2724.93823,486.598,3803.51025,724.840,
2725.02979,487.598,3803.60181,724.840,
2725.12134,487.598,3803.69312,724.840,
2725.21289,487.598,3803.78467,725.840,
2725.30444,487.598,3803.87622,725.840,
2725.39600,487.598,3803.96777,725.840,
2725.48755,486.598,3804.05933,726.840,
2725.57910,487.598,3804.15088,726.840,
2725.67041,487.598,3804.24243,726.840,
2725.76196,487.598,3804.33398,727.840,
2725.85352,487.598,3804.42529,726.840,
2725.94507,487.598,3804.51685,727.840,
2726.03662,488.598,3804.60840,728.840,
2726.12817,488.598,3804.69995,728.840,
2726.21973,488.598,3804.79150,728.840,
2726.31104,488.598,3804.88306,728.840,
2726.40259,488.598,3804.97461,728.840,
2726.49414,488.598,3805.06616,728.840,
2726.58569,489.598,3805.15747,729.840,
2726.67725,489.598,3805.24902,730.840,
2726.76880,488.598,3805.34058,729.840,
2726.86035,489.598,3805.43213,729.840,
2726.95190,489.598,3805.52368,729.840,
2727.04321,489.598,3805.61523,729.840,
2727.13477,489.598,3805.70679,730.840,
2727.22632,489.598,3805.79810,730.840,
2727.31787,490.598,3805.88965,730.840,
2727.40942,490.598,3805.98120,729.840,
2727.50098,491.598,3806.07275,730.840,
2727.59253,491.598,3806.16431,730.840,
2727.68408,491.598,3806.25586,730.840,
2727.77539,491.598,3806.34741,731.840,
2727.86694,492.598,3806.43896,731.840,
2727.95850,492.598,3806.53027,731.840,
2728.05005,492.598,3806.62183,731.840,
2728.14160,492.598,3806.71338,732.840,
2728.23315,492.598,3806.80493,731.840,
2728.32471,492.598,3806.89648,732.840,
2728.41602,492.598,3806.98804,732.840,
2728.50757,492.598,3807.07959,732.840,
2728.59912,492.598,3807.17090,732.840,
2728.69067,492.598,3807.26245,732.840,
2728.78223,491.598,3807.35400,732.840,
2728.87378,491.598,3807.44556,733.840,
2728.96533,493.598,3807.53711,733.840,
2729.05688,492.598,3807.62866,733.840,
2729.14819,491.598,3807.72021,733.840,
2729.23975,492.598,3807.81177,733.840,
2729.33130,492.598,3807.90308,734.840,
2729.42285,492.598,3807.99463,733.840,
2729.51440,491.598,3808.08618,734.840,
2729.60596,491.598,3808.17773,735.840,
2729.69751,492.598,3808.26929,735.840,
2729.78882,491.598,3808.36084,734.840,
2729.88037,492.598,3808.45239,735.840,
2729.97192,491.598,3808.54395,735.840,
2730.06348,491.598,3808.63525,735.840,
2730.15503,491.598,3808.72681,735.840,
2730.24658,492.598,3808.81836,736.840,
2730.33813,492.598,3808.90991,735.840,
2730.42969,492.598,3809.00146,736.840,
2730.52100,492.598,3809.09302,736.840,
2730.61255,492.598,3809.18457,736.840,
2730.70410,492.598,3809.27588,736.840,
2730.79565,493.598,3809.36743,736.840,
2730.88721,493.598,3809.45898,737.840,
2730.97876,493.598,3809.55054,737.840,
2731.07031,493.598,3809.64209,737.840,
2731.16187,494.598,3809.73364,737.840,
2731.25317,493.598,3809.82520,737.840,
2731.34473,494.598,3809.91675,737.840,
2731.43628,494.598,3810.00806,737.840,
2731.52783,494.598,3810.09961,738.840,
2731.61938,494.598,3810.19116,738.840,
2731.71094,494.598,3810.28271,738.840,
2731.80249,494.598,3810.37427,738.840,
2731.89380,495.598,3810.46582,739.840,
2731.98535,495.598,3810.55737,739.840,
2732.07690,495.598,3810.64893,739.840,
2732.16846,495.598,3810.74023,739.840,
2732.26001,495.598,3810.83179,739.840,
2732.35156,495.598,3810.92334,739.840,
2732.44312,496.598,3811.01489,739.840,
2732.53467,496.598,3811.10645,740.840,
2732.62598,496.598,3811.19800,740.840,
2732.71753,496.598,3811.28955,740.840,
2732.80908,495.598,3811.38086,740.840,
2732.90063,495.598,3811.47241,740.840,
2732.99219,496.598,3811.56396,740.840,
2733.08374,496.598,3811.65552,741.840,
2733.17529,496.598,3811.74707,741.840,
2733.26685,496.598,3811.83862,741.840,
2733.35815,497.598,3811.93018,741.840,
2733.44971,496.598,3812.02173,741.840,
2733.54126,497.598,3812.11304,742.840,
2733.63281,497.598,3812.20459,742.840,
2733.72437,497.598,3812.29614,742.840,
2733.81592,498.598,3812.38770,742.840,
2733.90747,497.598,3812.47925,742.840,
2733.99878,497.598,3812.57080,743.840,
2734.09033,497.598,3812.66235,742.840,
2734.18188,498.598,3812.75366,743.840,
2734.27344,498.598,3812.84521,743.840,
2734.36499,498.598,3812.93677,743.840,
2734.45654,498.598,3813.02832,744.840,
2734.54810,498.598,3813.11987,744.840,
2734.63965,498.598,3813.21143,744.840,
2734.73096,498.598,3813.30298,744.840,
2734.82251,499.598,3813.39453,745.840,
2734.91406,499.598,3813.48584,744.840,
2735.00562,499.598,3813.57739,745.840,
2735.09717,499.598,3813.66895,745.840,
2735.18872,499.598,3813.76050,745.840,
2735.28027,499.598,3813.85205,745.840,
2735.37158,499.598,3813.94360,745.840,
2735.46313,499.598,3814.03516,747.840,
2735.55469,499.598,3814.12671,745.840,
2735.64624,499.598,3814.21802,746.840,
2735.73779,499.598,3814.30957,746.840,
2735.82935,500.598,3814.40112,746.840,
2735.92090,499.598,3814.49268,747.840,
2736.01245,499.598,3814.58423,747.840,
2736.10376,500.598,3814.67578,747.840,
2736.19531,500.598,3814.76733,747.840,
2736.28687,500.598,3814.85864,748.840,
2736.37842,501.598,3814.95020,748.840,
2736.46997,500.598,3815.04175,747.840,
2736.56152,501.598,3815.13330,748.840,
2736.65308,501.598,3815.22485,748.840,
2736.74463,501.598,3815.31641,748.840,
2736.83594,501.598,3815.40796,748.840,
2736.92749,501.598,3815.49951,750.840,
2737.01904,501.598,3815.59082,749.840,
2737.11060,501.598,3815.68237,749.840,
2737.20215,501.598,3815.77393,749.840,
2737.29370,502.598,3815.86548,749.840,
2737.38525,502.598,3815.95703,749.840,
2737.47656,502.598,3816.04858,750.840,
2737.56812,502.598,3816.14014,750.840,
2737.65967,502.598,3816.23169,749.840,
2737.75122,503.598,3816.32300,750.840,
2737.84277,503.598,3816.41455,750.840,
2737.93433,503.598,3816.50610,750.840,
2738.02588,502.598,3816.59766,751.840,
2738.11743,503.598,3816.68921,751.840,
2738.20874,503.598,3816.78076,751.840,
2738.30029,503.598,3816.87231,751.840,
2738.39185,503.598,3816.96362,752.840,
2738.48340,503.598,3817.05518,752.840,
2738.57495,503.598,3817.14673,752.840,
2738.66650,503.598,3817.23828,752.840,
2738.75806,503.598,3817.32983,752.840,
2738.84961,503.598,3817.42139,752.840,
2738.94092,504.598,3817.51294,752.840,
2739.03247,503.598,3817.60449,753.840,
2739.12402,504.598,3817.69580,753.840,
2739.21558,505.598,3817.78735,753.840,
2739.30713,504.598,3817.87891,753.840,
2739.39868,504.598,3817.97046,754.840,
2739.49023,504.598,3818.06201,754.840,
2739.58154,504.598,3818.15356,753.840,
2739.67310,505.598,3818.24512,754.840,
2739.76465,505.598,3818.33667,754.840,
2739.85620,505.598,3818.42798,755.840,
2739.94775,505.598,3818.51953,754.840,
2740.03931,505.598,3818.61108,755.840,
2740.13086,505.598,3818.70264,754.840,
2740.22241,505.598,3818.79419,755.840,
2740.31372,505.598,3818.88574,755.840,
2740.40527,506.598,3818.97729,756.840,
2740.49683,505.598,3819.06860,756.840,
2740.58838,506.598,3819.16016,756.840,
2740.67993,507.598,3819.25171,756.840,
2740.77148,506.598,3819.34326,756.840,
2740.86304,507.598,3819.43481,757.840,
2740.95435,507.598,3819.52637,757.840,
2741.04590,506.598,3819.61792,757.840,
2741.13745,506.598,3819.70947,757.840,
2741.22900,507.598,3819.80078,757.840,
2741.32056,507.598,3819.89233,759.840,
2741.41211,507.598,3819.98389,758.840,
2741.50366,506.598,3820.07544,758.840,
2741.59521,507.598,3820.16699,758.840,
2741.68652,506.598,3820.25854,758.840,
2741.77808,507.598,3820.35010,759.840,
2741.86963,508.598,3820.44141,759.840,
2741.96118,507.598,3820.53296,759.840,
2742.05273,507.598,3820.62451,759.840,
2742.14429,508.598,3820.71606,759.840,
2742.23584,508.598,3820.80762,759.840,
2742.32739,508.598,3820.89917,759.840,
2742.41870,508.598,3820.99072,760.840,
2742.51025,508.598,3821.08228,760.840,
2742.60181,508.598,3821.17358,761.840,
2742.69336,508.598,3821.26514,761.840,
2742.78491,509.598,3821.35669,762.840,
2742.87646,509.598,3821.44824,761.840,
2742.96802,509.598,3821.53979,762.840,
2743.05933,509.598,3821.63135,762.840,
2743.15088,508.598,3821.72290,762.840,
2743.24243,509.598,3821.81445,762.840,
2743.33398,509.598,3821.90576,762.840,
2743.42554,509.598,3821.99731,762.840,
2743.51709,510.598,3822.08887,762.840,
2743.60864,510.598,3822.18042,763.840,
2743.70020,510.598,3822.27197,762.840,
2743.79150,510.598,3822.36353,762.840,
2743.88306,510.598,3822.45508,762.840,
2743.97461,510.598,3822.54639,763.840,
2744.06616,510.598,3822.63794,763.840,
2744.15771,511.598,3822.72949,763.840,
2744.24927,510.598,3822.82104,764.840,
2744.34082,510.598,3822.91260,764.840,
2744.43237,510.598,3823.00415,764.840,
2744.52368,511.598,3823.09570,764.840,
2744.61523,511.598,3823.18726,764.840,
2744.70679,511.598,3823.27856,764.840,
2744.79834,511.598,3823.37012,764.840,
2744.88989,511.598,3823.46167,765.840,
2744.98145,511.598,3823.55322,764.840,
2745.07300,512.598,3823.64478,764.840,
2745.16431,512.598,3823.73633,765.840,
2745.25586,511.598,3823.82788,764.840,
2745.34741,512.598,3823.91943,765.840,
2745.43896,512.598,3824.01074,765.840,
2745.53052,512.598,3824.10229,765.840,
2745.62207,511.598,3824.19385,766.840,
2745.71362,512.598,3824.28540,767.840,
2745.80518,512.598,3824.37695,767.840,
2745.89648,512.598,3824.46851,766.840,
2745.98804,512.598,3824.56006,767.840,
2746.07959,513.598,3824.65137,767.840,
2746.17114,513.598,3824.74292,767.840,
2746.26270,513.598,3824.83447,767.840,
2746.35425,513.598,3824.92603,767.840,
2746.44580,513.598,3825.01758,767.840,
2746.53711,514.598,3825.10913,767.840,
2746.62866,513.598,3825.20068,768.840,
2746.72021,514.598,3825.29224,768.840,
2746.81177,513.598,3825.38354,768.840,
2746.90332,514.598,3825.47510,769.840,
2746.99487,514.598,3825.56665,769.840,
2747.08643,514.598,3825.65820,769.840,
2747.17798,514.598,3825.74976,769.840,
2747.26929,514.598,3825.84131,769.840,
2747.36084,514.598,3825.93286,769.840,
2747.45239,514.598,3826.02417,770.840,
2747.54395,514.598,3826.11572,770.840,
2747.63550,514.598,3826.20728,771.840,
2747.72705,515.598,3826.29883,770.840,
2747.81860,514.598,3826.39038,771.840,
2747.91016,515.598,3826.48193,771.840,
2748.00146,516.598,3826.57349,771.840,
2748.09302,515.598,3826.66504,772.840,
2748.18457,515.598,3826.75635,771.840,
2748.27612,515.598,3826.84790,772.840,
2748.36768,515.598,3826.93945,772.840,
2748.45923,515.598,3827.03101,772.840,
2748.55078,515.598,3827.12256,773.840,
2748.64209,515.598,3827.21411,773.840,
2748.73364,516.598,3827.30566,773.840,
2748.82520,516.598,3827.39722,773.840,
2748.91675,516.598,3827.48853,773.840,
2749.00830,516.598,3827.58008,774.840,
2749.09985,516.598,3827.67163,774.840,
2749.19141,517.598,3827.76318,774.840,
2749.28296,516.598,3827.85474,774.840,
2749.37427,517.598,3827.94629,774.840,
2749.46582,517.598,3828.03784,774.840,
2749.55737,517.598,3828.12915,774.840,
2749.64893,517.598,3828.22070,774.840,
2749.74048,518.598,3828.31226,775.840,
2749.83203,518.598,3828.40381,775.840,
2749.92358,518.598,3828.49536,775.840,
2750.01514,519.598,3828.58691,776.840,
2750.10645,519.598,3828.67847,776.840,
2750.19800,519.598,3828.77002,776.840,
2750.28955,519.598,3828.86133,776.840,
2750.38110,520.598,3828.95288,777.840,
2750.47266,520.598,3829.04443,776.840,
2750.56421,520.598,3829.13599,777.840,
2750.65576,521.598,3829.22754,777.840,
2750.74707,521.598,3829.31909,777.840,
2750.83862,520.598,3829.41064,777.840,
2750.93018,521.598,3829.50220,777.840,
2751.02173,521.598,3829.59351,777.840,
2751.11328,521.598,3829.68506,778.840,
2751.20483,520.598,3829.77661,778.840,
2751.29639,521.598,3829.86816,778.840,
2751.38794,521.598,3829.95972,778.840,
2751.47925,521.598,3830.05127,779.840,
2751.57080,520.598,3830.14282,779.840,
2751.66235,521.598,3830.23413,779.840,
2751.75391,520.598,3830.32568,779.840,
2751.84546,521.598,3830.41724,779.840,
2751.93701,520.598,3830.50879,780.840,
2752.02856,520.598,3830.60034,780.840,
2752.12012,520.598,3830.69189,780.840,
2752.21143,520.598,3830.78345,780.840,
2752.30298,521.598,3830.87500,780.840,
2752.39453,520.598,3830.96631,781.840,
2752.48608,520.598,3831.05786,781.840,
2752.57764,519.598,3831.14941,781.840,
2752.66919,519.598,3831.24097,781.840,
2752.76074,519.598,3831.33252,781.840,
2752.85205,519.598,3831.42407,781.840,
2752.94360,519.598,3831.51563,782.840,
2753.03516,519.598,3831.60693,782.840,
2753.12671,519.598,3831.69849,782.840,
2753.21826,520.598,3831.79004,782.840,
2753.30981,519.598,3831.88159,782.840,
2753.40137,520.598,3831.97314,783.840,
2753.49292,520.598,3832.06470,783.840,
2753.58423,521.598,3832.15625,783.840,
2753.67578,521.598,3832.24780,783.840,
2753.76733,522.598,3832.33911,783.840,
2753.85889,522.598,3832.43066,783.840,
2753.95044,522.598,3832.52222,784.840,
2754.04199,522.598,3832.61377,784.840,
2754.13354,522.598,3832.70532,784.840,
2754.22485,522.598,3832.79688,785.840,
2754.31641,523.598,3832.88843,785.840,
2754.40796,523.598,3832.97998,785.840,
2754.49951,523.598,3833.07129,785.840,
2754.59106,524.598,3833.16284,785.840,
2754.68262,524.598,3833.25439,785.840,
2754.77417,523.598,3833.34595,785.840,
2754.86572,524.598,3833.43750,786.840,
2754.95703,524.598,3833.52905,786.840,
2755.04858,524.598,3833.62061,786.840,
2755.14014,524.598,3833.71191,786.840,
2755.23169,525.598,3833.80347,787.840,
2755.32324,525.598,3833.89502,787.840,
2755.41479,525.598,3833.98657,787.840,
2755.50635,525.598,3834.07813,787.840,
2755.59790,525.598,3834.16968,787.840,
2755.68921,525.598,3834.26123,787.840,
2755.78076,525.598,3834.35278,787.840,
2755.87231,526.598,3834.44409,787.840,
2755.96387,525.598,3834.53564,788.840,
2756.05542,525.598,3834.62720,788.840,
2756.14697,526.598,3834.71875,789.840,
2756.23853,526.598,3834.81030,788.840,
2756.32983,526.598,3834.90186,789.840,
2756.42139,526.598,3834.99341,789.840,
2756.51294,526.598,3835.08496,789.840,
2756.60449,526.598,3835.17627,790.840,
2756.69604,527.598,3835.26782,790.840,
2756.78760,527.598,3835.35938,790.840,
2756.87915,527.598,3835.45093,790.840,
2756.97070,526.598,3835.54248,790.840,
2757.06201,527.598,3835.63403,790.840,
2757.15356,526.598,3835.72559,791.840,
2757.24512,527.598,3835.81689,791.840,
2757.33667,527.598,3835.90845,791.840,
2757.42822,527.598,3836.00000,792.840,
2757.51978,528.598,3836.09155,791.840,
2757.61133,527.598,3836.18311,791.840,
2757.70288,527.598,3836.27466,791.840,
2757.79419,527.598,3836.36621,792.840,
2757.88574,527.598,3836.45776,792.840,
2757.97729,527.598,3836.54907,792.840,
2758.06885,528.598,3836.64063,792.840,
2758.16040,528.598,3836.73218,793.840,
2758.25195,528.598,3836.82373,793.840,
2758.34351,528.598,3836.91528,793.840,
2758.43481,528.598,3837.00684,793.840,
2758.52637,528.598,3837.09839,793.840,
2758.61792,529.598,3837.18994,793.840,
2758.70947,528.598,3837.28125,794.840,
2758.80103,529.598,3837.37280,794.840,
2758.89258,529.598,3837.46436,794.840,
2758.98413,529.598,3837.55591,795.840,
2759.07568,529.598,3837.64746,795.840,
2759.16699,530.598,3837.73901,795.840,
2759.25854,529.598,3837.83057,795.840,
2759.35010,530.598,3837.92188,796.840,
2759.44165,530.598,3838.01343,795.840,
2759.53320,530.598,3838.10498,796.840,
2759.62476,529.598,3838.19653,796.840,
2759.71631,531.598,3838.28809,796.840,
2759.80762,530.598,3838.37964,796.840,
2759.89917,530.598,3838.47119,797.840,
2759.99072,530.598,3838.56274,797.840,
2760.08228,531.598,3838.65405,797.840,
2760.17383,531.598,3838.74561,797.840,
2760.26538,530.598,3838.83716,797.840,
2760.35693,531.598,3838.92871,798.840,
2760.44849,531.598,3839.02026,797.840,
2760.53979,531.598,3839.11182,798.840,
2760.63135,531.598,3839.20337,798.840,
2760.72290,532.598,3839.29468,798.840,
2760.81445,531.598,3839.38623,798.840,
2760.90601,531.598,3839.47778,799.840,
2760.99756,532.598,3839.56934,799.840,
2761.08911,532.598,3839.66089,799.840,
2761.18066,532.598,3839.75244,799.840,
2761.27197,532.598,3839.84399,799.840,
2761.36353,532.598,3839.93555,799.840,
2761.45508,532.598,3840.02686,800.840,
2761.54663,532.598,3840.11841,800.840,
2761.63818,533.598,3840.20996,800.840,
2761.72974,533.598,3840.30151,800.840,
2761.82129,532.598,3840.39307,801.840,
2761.91260,532.598,3840.48462,801.840,
2762.00415,533.598,3840.57617,801.840,
2762.09570,533.598,3840.66772,801.840,
2762.18726,533.598,3840.75903,801.840,
2762.27881,533.598,3840.85059,801.840,
2762.37036,533.598,3840.94214,801.840,
2762.46191,533.598,3841.03369,802.840,
2762.55347,533.598,3841.12524,801.840,
2762.64478,534.598,3841.21680,802.840,
2762.73633,534.598,3841.30835,802.840,
2762.82788,535.598,3841.39966,802.840,
2762.91943,535.598,3841.49121,802.840,
2763.01099,535.598,3841.58276,802.840,
2763.10254,535.598,3841.67432,803.840,
2763.19409,535.598,3841.76587,803.840,
2763.28564,535.598,3841.85742,804.840,
2763.37695,535.598,3841.94897,804.840,
2763.46851,535.598,3842.04053,804.840,
2763.56006,535.598,3842.13184,804.840,
2763.65161,535.598,3842.22339,805.840,
2763.74316,536.598,3842.31494,805.840,
2763.83472,535.598,3842.40649,805.840,
2763.92627,535.598,3842.49805,805.840,
2764.01758,536.598,3842.58960,805.840,
2764.10913,537.598,3842.68115,805.840,
2764.20068,536.598,3842.77271,806.840,
2764.29224,536.598,3842.86401,807.840,
2764.38379,537.598,3842.95557,806.840,
2764.47534,537.598,3843.04712,807.840,
2764.56689,537.598,3843.13867,807.840,
2764.65845,537.598,3843.23022,807.840,
2764.74976,536.598,3843.32178,807.840,
2764.84131,537.598,3843.41333,807.840,
2764.93286,537.598,3843.50464,808.840,
2765.02441,537.598,3843.59619,808.840,
2765.11597,537.598,3843.68774,808.840,
2765.20752,537.598,3843.77930,808.840,
2765.29907,537.598,3843.87085,808.840,
2765.39038,538.598,3843.96240,808.840,
2765.48193,538.598,3844.05396,808.840,
2765.57349,538.598,3844.14551,809.840,
2765.66504,538.598,3844.23682,809.840,
2765.75659,538.598,3844.32837,809.840,
2765.84814,538.598,3844.41992,809.840,
2765.93970,539.598,3844.51147,809.840,
2766.03125,538.598,3844.60303,809.840,
2766.12256,539.598,3844.69458,809.840,
2766.21411,539.598,3844.78613,810.840,
2766.30566,539.598,3844.87744,810.840,
2766.39722,539.598,3844.96899,811.840,
2766.48877,539.598,3845.06055,811.840,
2766.58032,539.598,3845.15210,810.840,
2766.67188,539.598,3845.24365,812.840,
2766.76343,539.598,3845.33521,811.840,
2766.85474,540.598,3845.42676,812.840,
2766.94629,539.598,3845.51831,812.840,
2767.03784,540.598,3845.60962,812.840,
2767.12939,540.598,3845.70117,812.840,
2767.22095,540.598,3845.79272,812.840,
2767.31250,540.598,3845.88428,813.840,
2767.40405,541.598,3845.97583,813.840,
2767.49536,541.598,3846.06738,813.840,
2767.58691,541.598,3846.15894,813.840,
2767.67847,541.598,3846.25049,814.840,
2767.77002,541.598,3846.34180,814.840,
2767.86157,541.598,3846.43335,814.840,
2767.95313,541.598,3846.52490,814.840,
2768.04468,541.598,3846.61646,814.840,
2768.13623,541.598,3846.70801,814.840,
2768.22754,541.598,3846.79956,815.840,
2768.31909,541.598,3846.89111,815.840,
2768.41064,542.598,3846.98242,815.840,
2768.50220,542.598,3847.07397,815.840,
2768.59375,542.598,3847.16553,815.840,
2768.68530,542.598,3847.25708,815.840,
2768.77686,542.598,3847.34863,816.840,
2768.86841,542.598,3847.44019,816.840,
2768.95972,542.598,3847.53174,817.840,
2769.05127,543.598,3847.62329,816.840,
2769.14282,543.598,3847.71460,818.840,
2769.23438,543.598,3847.80615,817.840,
2769.32593,543.598,3847.89771,817.840,
2769.41748,543.598,3847.98926,817.840,
2769.50903,543.598,3848.08081,818.840,
2769.60034,543.598,3848.17236,817.840,
2769.69189,543.598,3848.26392,818.840,
2769.78345,543.598,3848.35547,818.840,
2769.87500,543.598,3848.44678,818.840,
2769.96655,544.598,3848.53833,819.840,
2770.05811,544.598,3848.62988,819.840,
2770.14966,544.598,3848.72144,819.840,
2770.24121,544.598,3848.81299,819.840,
2770.33252,543.598,3848.90454,819.840,
2770.42407,544.598,3848.99609,819.840,
2770.51563,544.598,3849.08740,819.840,
2770.60718,545.598,3849.17896,821.840,
2770.69873,545.598,3849.27051,820.840,
2770.79028,545.598,3849.36206,820.840,
2770.88184,545.598,3849.45361,820.840,
2770.97339,545.598,3849.54517,821.840,
2771.06470,545.598,3849.63672,821.840,
2771.15625,545.598,3849.72827,821.840,
2771.24780,545.598,3849.81958,822.840,
2771.33936,545.598,3849.91113,822.840,
2771.43091,546.598,3850.00269,822.840,
2771.52246,545.598,3850.09424,822.840,
2771.61401,546.598,3850.18579,823.840,
2771.70532,546.598,3850.27734,822.840,
2771.79688,547.598,3850.36890,822.840,
2771.88843,546.598,3850.46021,823.840,
2771.97998,547.598,3850.55176,823.840,
2772.07153,547.598,3850.64331,824.840,
2772.16309,547.598,3850.73486,823.840,
2772.25464,548.598,3850.82642,824.840,
2772.34619,549.598,3850.91797,823.840,
2772.43750,548.598,3851.00952,824.840,
2772.52905,549.598,3851.10107,824.840,
2772.62061,549.598,3851.19238,824.840,
2772.71216,549.598,3851.28394,824.840,
2772.80371,550.598,3851.37549,824.840,
2772.89526,550.598,3851.46704,825.840,
2772.98682,550.598,3851.55859,825.840,
2773.07813,549.598,3851.65015,826.840,
2773.16968,550.598,3851.74170,825.840,
2773.26123,550.598,3851.83325,825.840,
2773.35278,550.598,3851.92456,826.840,
2773.44434,549.598,3852.01611,826.840,
2773.53589,549.598,3852.10767,827.840,
2773.62744,549.598,3852.19922,827.840,
2773.71899,549.598,3852.29077,827.840,
2773.81030,549.598,3852.38232,826.840,
2773.90186,549.598,3852.47388,827.840,
2773.99341,549.598,3852.56519,828.840,
2774.08496,549.598,3852.65674,827.840,
2774.17651,549.598,3852.74829,827.840,
2774.26807,549.598,3852.83984,828.840,
2774.35962,550.598,3852.93140,827.840,
2774.45117,551.598,3853.02295,828.840,
2774.54248,551.598,3853.11450,828.840,
2774.63403,552.598,3853.20605,829.840,
2774.72559,553.598,3853.29736,829.840,
2774.81714,553.598,3853.38892,829.840,
2774.90869,553.598,3853.48047,829.840,
2775.00024,553.598,3853.57202,830.840,
2775.09180,553.598,3853.66357,829.840,
2775.18311,553.598,3853.75513,830.840,
2775.27466,553.598,3853.84668,830.840,
2775.36621,553.598,3853.93823,830.840,
2775.45776,553.598,3854.02954,831.840,
2775.54932,553.598,3854.12109,831.840,
2775.64087,553.598,3854.21265,831.840,
2775.73242,553.598,3854.30420,831.840,
2775.82397,553.598,3854.39575,831.840,
2775.91528,552.598,3854.48730,831.840,
2776.00684,553.598,3854.57886,831.840,
2776.09839,553.598,3854.67017,832.840,
2776.18994,553.598,3854.76172,832.840,
2776.28149,553.598,3854.85327,832.840,
2776.37305,553.598,3854.94482,832.840,
2776.46460,552.598,3855.03638,833.840,
2776.55615,553.598,3855.12793,833.840,
2776.64746,553.598,3855.21948,833.840,
2776.73901,553.598,3855.31104,833.840,
2776.83057,553.598,3855.40234,833.840,
2776.92212,553.598,3855.49390,834.840,
2777.01367,553.598,3855.58545,834.840,
2777.10522,553.598,3855.67700,834.840,
2777.19678,553.598,3855.76855,834.840,
2777.28809,554.598,3855.86011,834.840,
2777.37964,553.598,3855.95166,835.840,
2777.47119,553.598,3856.04321,835.840,
2777.56274,554.598,3856.13452,835.840,
2777.65430,554.598,3856.22607,835.840,
2777.74585,554.598,3856.31763,835.840,
2777.83740,554.598,3856.40918,835.840,
2777.92896,554.598,3856.50073,837.840,
2778.02026,555.598,3856.59229,836.840,
2778.11182,555.598,3856.68384,836.840,
2778.20337,555.598,3856.77515,836.840,
2778.29492,555.598,3856.86670,837.840,
2778.38647,555.598,3856.95825,837.840,
2778.47803,555.598,3857.04980,837.840,
2778.56958,555.598,3857.14136,837.840,
2778.66089,555.598,3857.23291,837.840,
2778.75244,556.598,3857.32446,837.840,
2778.84399,556.598,3857.41602,838.840,
2778.93555,555.598,3857.50732,838.840,
2779.02710,556.598,3857.59888,838.840,
2779.11865,556.598,3857.69043,838.840,
2779.21021,557.598,3857.78198,839.840,
2779.30176,556.598,3857.87354,839.840,
2779.39307,557.598,3857.96509,840.840,
2779.48462,556.598,3858.05664,839.840,
2779.57617,557.598,3858.14795,840.840,
2779.66772,557.598,3858.23950,840.840,
2779.75928,557.598,3858.33105,840.840,
2779.85083,557.598,3858.42261,840.840,
2779.94238,557.598,3858.51416,840.840,
2780.03394,557.598,3858.60571,841.840,
2780.12524,557.598,3858.69727,841.840,
2780.21680,558.598,3858.78882,841.840,
2780.30835,558.598,3858.88013,841.840,
2780.39990,558.598,3858.97168,841.840,
2780.49146,558.598,3859.06323,841.840,
2780.58301,558.598,3859.15479,841.840,
2780.67456,558.598,3859.24634,842.840,
2780.76587,559.598,3859.33789,842.840,
2780.85742,559.598,3859.42944,843.840,
2780.94897,559.598,3859.52100,843.840,
2781.04053,558.598,3859.61230,843.840,
2781.13208,559.598,3859.70386,843.840,
2781.22363,559.598,3859.79541,843.840,
2781.31519,559.598,3859.88696,843.840,
2781.40674,559.598,3859.97852,843.840,
2781.49805,559.598,3860.07007,844.840,
2781.58960,559.598,3860.16162,844.840,
2781.68115,560.598,3860.25293,844.840,
2781.77271,559.598,3860.34448,844.840,
2781.86426,560.598,3860.43604,844.840,
2781.95581,560.598,3860.52759,844.840,
2782.04736,560.598,3860.61914,844.840,
2782.13892,560.598,3860.71069,844.840,
2782.23022,560.598,3860.80225,844.840,
2782.32178,560.598,3860.89380,846.840,
2782.41333,561.598,3860.98511,845.840,
2782.50488,561.598,3861.07666,846.840,
2782.59644,560.598,3861.16821,846.840,
2782.68799,561.598,3861.25977,845.840,
2782.77954,561.598,3861.35132,846.840,
2782.87085,561.598,3861.44287,846.840,
2782.96240,560.598,3861.53442,847.840,
2783.05396,561.598,3861.62598,847.840,
2783.14551,561.598,3861.71729,847.840,
2783.23706,562.598,3861.80884,847.840,
2783.32861,562.598,3861.90039,847.840,
2783.42017,562.598,3861.99194,848.840,
2783.51172,562.598,3862.08350,848.840,
2783.60303,562.598,3862.17505,848.840,
2783.69458,562.598,3862.26660,849.840,
2783.78613,562.598,3862.35791,850.840,
2783.87769,563.598,3862.44946,849.840,
2783.96924,562.598,3862.54102,849.840,
2784.06079,562.598,3862.63257,850.840,
2784.15234,563.598,3862.72412,850.840,
2784.24365,563.598,3862.81567,850.840,
2784.33521,563.598,3862.90723,851.840,
2784.42676,563.598,3862.99878,851.840,
2784.51831,563.598,3863.09009,851.840,
2784.60986,564.598,3863.18164,851.840,
2784.70142,563.598,3863.27319,851.840,
2784.79297,564.598,3863.36475,852.840,
2784.88452,564.598,3863.45630,852.840,
2784.97583,564.598,3863.54785,852.840,
2785.06738,564.598,3863.63940,852.840,
2785.15894,565.598,3863.73071,853.840,
2785.25049,564.598,3863.82227,853.840,
2785.34204,564.598,3863.91382,853.840,
2785.43359,564.598,3864.00537,853.840,
2785.52515,564.598,3864.09692,853.840,
2785.61670,565.598,3864.18848,853.840,
2785.70801,565.598,3864.28003,853.840,
2785.79956,565.598,3864.37158,853.840,
2785.89111,565.598,3864.46289,854.840,
2785.98267,565.598,3864.55444,854.840,
2786.07422,566.598,3864.64600,854.840,
2786.16577,565.598,3864.73755,854.840,
2786.25732,566.598,3864.82910,854.840,
2786.34863,566.598,3864.92065,854.840,
2786.44019,566.598,3865.01221,855.840,
2786.53174,566.598,3865.10376,855.840,
2786.62329,566.598,3865.19507,855.840,
2786.71484,567.598,3865.28662,856.840,
2786.80640,566.598,3865.37817,855.840,
2786.89795,567.598,3865.46973,855.840,
2786.98950,567.598,3865.56128,856.840,
2787.08081,567.598,3865.65283,856.840,
2787.17236,567.598,3865.74438,856.840,
2787.26392,567.598,3865.83569,856.840,
2787.35547,568.598,3865.92725,857.840,
2787.44702,567.598,3866.01880,857.840,
2787.53857,568.598,3866.11035,857.840,
2787.63013,568.598,3866.20190,857.840,
2787.72168,568.598,3866.29346,857.840,
2787.81299,568.598,3866.38501,857.840,
2787.90454,568.598,3866.47656,858.840,
2787.99609,568.598,3866.56787,858.840,
2788.08765,568.598,3866.65942,858.840,
2788.17920,569.598,3866.75098,859.840,
2788.27075,569.598,3866.84253,859.840,
2788.36230,568.598,3866.93408,858.840,
2788.45361,569.598,3867.02563,859.840,
2788.54517,569.598,3867.11719,859.840,
2788.63672,569.598,3867.20874,860.840,
2788.72827,569.598,3867.30005,859.840,
2788.81982,569.598,3867.39160,860.840,
2788.91138,569.598,3867.48315,860.840,
2789.00293,570.598,3867.57471,860.840,
2789.09448,570.598,3867.66626,861.840,
2789.18579,570.598,3867.75781,861.840,
2789.27734,569.598,3867.84937,861.840,
2789.36890,570.598,3867.94067,861.840,
2789.46045,570.598,3868.03223,862.840,
2789.55200,570.598,3868.12378,862.840,
2789.64355,570.598,3868.21533,863.840,
2789.73511,570.598,3868.30688,862.840,
2789.82666,570.598,3868.39844,863.840,
2789.91797,571.598,3868.48999,863.840,
2790.00952,571.598,3868.58154,863.840,
2790.10107,571.598,3868.67285,863.840,
2790.19263,571.598,3868.76440,863.840,
2790.28418,571.598,3868.85596,863.840,
2790.37573,571.598,3868.94751,864.840,
2790.46729,572.598,3869.03906,864.840,
2790.55859,572.598,3869.13062,863.840,
2790.65015,571.598,3869.22217,864.840,
2790.74170,572.598,3869.31348,865.840,
2790.83325,572.598,3869.40503,864.840,
2790.92480,572.598,3869.49658,865.840,
2791.01636,573.598,3869.58813,865.840,
2791.10791,572.598,3869.67969,866.840,
2791.19946,573.598,3869.77124,865.840,
2791.29077,572.598,3869.86279,866.840,
2791.38232,573.598,3869.95435,865.840,
2791.47388,573.598,3870.04565,866.840,
2791.56543,572.598,3870.13721,866.840,
2791.65698,573.598,3870.22876,867.840,
2791.74854,574.598,3870.32031,867.840,
2791.84009,574.598,3870.41187,867.840,
2791.93140,574.598,3870.50342,868.840,
2792.02295,574.598,3870.59497,867.840,
2792.11450,574.598,3870.68652,867.840,
2792.20605,574.598,3870.77783,868.840,
2792.29761,575.598,3870.86938,868.840,
2792.38916,575.598,3870.96094,868.840,
2792.48071,575.598,3871.05249,868.840,
2792.57227,575.598,3871.14404,869.840,
2792.66357,575.598,3871.23560,868.840,
2792.75513,575.598,3871.32715,869.840,
2792.84668,575.598,3871.41846,869.840,
2792.93823,575.598,3871.51001,869.840,
2793.02979,575.598,3871.60156,870.840,
2793.12134,575.598,3871.69312,870.840,
2793.21289,575.598,3871.78467,870.840,
2793.30444,574.598,3871.87622,870.840,
2793.39575,575.598,3871.96777,870.840,
2793.48730,573.598,3872.05933,871.840,
2793.57886,573.598,3872.15063,871.840,
2793.67041,573.598,3872.24219,871.840,
2793.76196,573.598,3872.33374,871.840,
2793.85352,573.598,3872.42529,871.840,
2793.94507,574.598,3872.51685,871.840,
2794.03638,574.598,3872.60840,872.840,
2794.12793,574.598,3872.69995,872.840,
2794.21948,573.598,3872.79150,872.840,
2794.31104,574.598,3872.88281,872.840,
2794.40259,574.598,3872.97437,873.840,
2794.49414,575.598,3873.06592,873.840,
2794.58569,576.598,3873.15747,873.840,
2794.67725,576.598,3873.24902,873.840,
2794.76855,576.598,3873.34058,873.840,
2794.86011,577.598,3873.43213,873.840,
2794.95166,577.598,3873.52344,873.840,
2795.04321,577.598,3873.61499,874.840,
2795.13477,578.598,3873.70654,874.840,
2795.22632,577.598,3873.79810,874.840,
2795.31787,578.598,3873.88965,874.840,
2795.40942,578.598,3873.98120,875.840,
2795.50073,579.598,3874.07275,875.840,
2795.59229,579.598,3874.16431,875.840,
2795.68384,579.598,3874.25562,875.840,
2795.77539,580.598,3874.34717,875.840,
2795.86694,580.598,3874.43872,876.840,
2795.95850,580.598,3874.53027,876.840,
2796.05005,581.598,3874.62183,876.840,
2796.14136,581.598,3874.71338,877.840,
2796.23291,581.598,3874.80493,876.840,
2796.32446,581.598,3874.89648,877.840,
2796.41602,581.598,3874.98779,877.840,
2796.50757,581.598,3875.07935,877.840,
2796.59912,581.598,3875.17090,877.840,
2796.69067,581.598,3875.26245,878.840,
2796.78223,581.598,3875.35400,878.840,
2796.87354,581.598,3875.44556,878.840,
2796.96509,581.598,3875.53711,879.840,
2797.05664,581.598,3875.62842,879.840,
2797.14819,581.598,3875.71997,879.840,
2797.23975,581.598,3875.81152,879.840,
2797.33130,581.598,3875.90308,879.840,
2797.42285,581.598,3875.99463,879.840,
2797.51416,581.598,3876.08618,879.840,
2797.60571,582.598,3876.17773,880.840,
2797.69727,583.598,3876.26929,880.840,
2797.78882,583.598,3876.36060,880.840,
2797.88037,582.598,3876.45215,880.840,
2797.97192,582.598,3876.54370,881.840,
2798.06348,583.598,3876.63525,881.840,
2798.15503,582.598,3876.72681,881.840,
2798.24634,583.598,3876.81836,881.840,
2798.33789,583.598,3876.90991,881.840,
2798.42944,583.598,3877.00122,882.840,
2798.52100,583.598,3877.09277,882.840,
2798.61255,583.598,3877.18433,882.840,
2798.70410,583.598,3877.27588,882.840,
2798.79565,583.598,3877.36743,882.840,
2798.88721,584.598,3877.45898,882.840,
2798.97852,583.598,3877.55054,883.840,
2799.07007,584.598,3877.64209,883.840,
2799.16162,585.598,3877.73340,883.840,
2799.25317,585.598,3877.82495,883.840,
2799.34473,584.598,3877.91650,883.840,
2799.43628,585.598,3878.00806,883.840,
2799.52783,584.598,3878.09961,884.840,
2799.61914,585.598,3878.19116,884.840,
2799.71069,585.598,3878.28271,884.840,
2799.80225,586.598,3878.37427,884.840,
2799.89380,585.598,3878.46558,885.840,
2799.98535,586.598,3878.55713,885.840,
2800.07690,585.598,3878.64868,886.840,
2800.16846,585.598,3878.74023,885.840,
2800.26001,585.598,3878.83179,886.840,
2800.35132,586.598,3878.92334,886.840,
2800.44287,586.598,3879.01489,886.840,
2800.53442,586.598,3879.10620,886.840,
2800.62598,586.598,3879.19775,886.840,
2800.71753,587.598,3879.28931,887.840,
2800.80908,586.598,3879.38086,886.840,
2800.90063,586.598,3879.47241,886.840,
2800.99219,587.598,3879.56396,887.840,
2801.08350,586.598,3879.65552,887.840,
2801.17505,587.598,3879.74707,888.840,
2801.26660,587.598,3879.83838,887.840,
2801.35815,587.598,3879.92993,888.840,
2801.44971,587.598,3880.02148,888.840,
2801.54126,588.598,3880.11304,888.840,
2801.63281,587.598,3880.20459,888.840,
2801.72412,588.598,3880.29614,889.840,
2801.81567,588.598,3880.38770,889.840,
2801.90723,588.598,3880.47925,889.840,
2801.99878,588.598,3880.57056,889.840,
2802.09033,588.598,3880.66211,890.840,
2802.18188,588.598,3880.75366,890.840,
2802.27344,588.598,3880.84521,890.840,
2802.36499,588.598,3880.93677,891.840,
2802.45630,588.598,3881.02832,891.840,
2802.54785,589.598,3881.11987,891.840,
2802.63940,588.598,3881.21118,892.840,
2802.73096,589.598,3881.30273,892.840,
2802.82251,588.598,3881.39429,893.840,
2802.91406,589.598,3881.48584,893.840,
2803.00562,589.598,3881.57739,893.840,
2803.09692,590.598,3881.66895,893.840,
2803.18848,590.598,3881.76050,893.840,
2803.28003,589.598,3881.85205,894.840,
2803.37158,590.598,3881.94336,894.840,
2803.46313,590.598,3882.03491,895.840,
2803.55469,590.598,3882.12646,894.840,
2803.64624,591.598,3882.21802,894.840,
2803.73779,590.598,3882.30957,895.840,
2803.82910,591.598,3882.40112,894.840,
2803.92065,590.598,3882.49268,895.840,
2804.01221,591.598,3882.58398,895.840,
2804.10376,591.598,3882.67554,895.840,
2804.19531,591.598,3882.76709,895.840,
2804.28687,592.598,3882.85864,896.840,
2804.37842,592.598,3882.95020,896.840,
2804.46997,591.598,3883.04175,896.840,
2804.56128,591.598,3883.13330,896.840,
2804.65283,592.598,3883.22485,896.840,
2804.74438,592.598,3883.31616,896.840,
2804.83594,592.598,3883.40771,896.840,
2804.92749,592.598,3883.49927,896.840,
2805.01904,592.598,3883.59082,897.840,
2805.11060,593.598,3883.68237,897.840,
2805.20190,592.598,3883.77393,897.840,
2805.29346,592.598,3883.86548,897.840,
2805.38501,592.598,3883.95703,897.840,
2805.47656,593.598,3884.04834,898.840,
2805.56812,593.598,3884.13989,898.840,
2805.65967,593.598,3884.23145,898.840,
2805.75122,593.598,3884.32300,899.840,
2805.84277,594.598,3884.41455,899.840,
2805.93408,593.598,3884.50610,899.840,
2806.02563,593.598,3884.59766,899.840,
2806.11719,594.598,3884.68896,899.840,
2806.20874,594.598,3884.78052,900.840,
2806.30029,593.598,3884.87207,900.840,
2806.39185,594.598,3884.96362,900.840,
2806.48340,594.598,3885.05518,900.840,
2806.57495,595.598,3885.14673,900.840,
2806.66626,595.598,3885.23828,900.840,
2806.75781,595.598,3885.32983,901.840,
2806.84937,595.598,3885.42114,901.840,
2806.94092,595.598,3885.51270,901.840,
2807.03247,595.598,3885.60425,902.840,
2807.12402,595.598,3885.69580,901.840,
2807.21558,595.598,3885.78735,902.840,
2807.30688,595.598,3885.87891,902.840,
2807.39844,595.598,3885.97046,903.840,
2807.48999,595.598,3886.06201,902.840,
2807.58154,595.598,3886.15332,902.840,
2807.67310,596.598,3886.24487,903.840,
2807.76465,596.598,3886.33643,903.840,
2807.85620,596.598,3886.42798,903.840,
2807.94775,596.598,3886.51953,904.840,
2808.03906,597.598,3886.61108,904.840,
2808.13062,596.598,3886.70264,904.840,
2808.22217,597.598,3886.79395,904.840,
2808.31372,597.598,3886.88550,904.840,
2808.40527,597.598,3886.97705,904.840,
2808.49683,597.598,3887.06860,905.840,
2808.58838,598.598,3887.16016,905.840,
2808.67993,598.598,3887.25171,906.840,
2808.77124,597.598,3887.34326,905.840,
2808.86279,598.598,3887.43481,905.840,
2808.95435,598.598,3887.52612,906.840,
2809.04590,598.598,3887.61768,906.840,
2809.13745,598.598,3887.70923,906.840,
2809.22900,598.598,3887.80078,907.840,
2809.32056,598.598,3887.89233,906.840,
2809.41187,598.598,3887.98389,907.840,
2809.50342,599.598,3888.07544,907.840,
2809.59497,599.598,3888.16675,907.840,
2809.68652,599.598,3888.25830,907.840,
2809.77808,599.598,3888.34985,907.840,
2809.86963,599.598,3888.44141,908.840,
2809.96118,599.598,3888.53296,908.840,
2810.05273,599.598,3888.62451,908.840,
2810.14404,599.598,3888.71606,909.840,
2810.23560,599.598,3888.80762,909.840,
2810.32715,599.598,3888.89893,909.840,
2810.41870,600.598,3888.99048,909.840,
2810.51025,599.598,3889.08203,909.840,
2810.60181,599.598,3889.17358,910.840,
2810.69336,600.598,3889.26514,910.840,
2810.78467,600.598,3889.35669,910.840,
2810.87622,600.598,3889.44824,910.840,
2810.96777,601.598,3889.53979,910.840,
2811.05933,601.598,3889.63110,910.840,
2811.15088,601.598,3889.72266,911.840,
2811.24243,601.598,3889.81421,911.840,
2811.33398,601.598,3889.90576,911.840,
2811.42554,601.598,3889.99731,911.840,
2811.51685,602.598,3890.08887,911.840,
2811.60840,601.598,3890.18042,912.840,
2811.69995,602.598,3890.27173,912.840,
2811.79150,602.598,3890.36328,912.840,
2811.88306,602.598,3890.45483,912.840,
2811.97461,602.598,3890.54639,913.840,
2812.06616,602.598,3890.63794,913.840,
2812.15771,602.598,3890.72949,913.840,
2812.24902,602.598,3890.82104,913.840,
2812.34058,602.598,3890.91260,913.840,
2812.43213,603.598,3891.00391,913.840,
2812.52368,603.598,3891.09546,914.840,
2812.61523,603.598,3891.18701,914.840,
2812.70679,603.598,3891.27856,914.840,
2812.79834,603.598,3891.37012,914.840,
2812.88965,604.598,3891.46167,915.840,
2812.98120,603.598,3891.55322,914.840,
2813.07275,604.598,3891.64478,915.840,
2813.16431,604.598,3891.73608,915.840,
2813.25586,604.598,3891.82764,916.840,
2813.34741,604.598,3891.91919,916.840,
2813.43896,604.598,3892.01074,916.840,
2813.53052,605.598,3892.10229,916.840,
2813.62183,605.598,3892.19385,916.840,
2813.71338,605.598,3892.28540,917.840,
2813.80493,606.598,3892.37671,917.840,
2813.89648,607.598,3892.46826,916.840,
2813.98804,607.598,3892.55981,917.840,
2814.07959,607.598,3892.65137,917.840,
2814.17114,608.598,3892.74292,917.840,
2814.26270,608.598,3892.83447,918.840,
2814.35400,608.598,3892.92603,918.840,
2814.44556,609.598,3893.01758,918.840,
2814.53711,608.598,3893.10889,919.840,
2814.62866,608.598,3893.20044,919.840,
2814.72021,608.598,3893.29199,919.840,
2814.81177,608.598,3893.38354,919.840,
2814.90332,608.598,3893.47510,920.840,
2814.99463,608.598,3893.56665,920.840,
2815.08618,608.598,3893.65820,920.840,
2815.17773,608.598,3893.74951,920.840,
2815.26929,608.598,3893.84106,921.840,
2815.36084,608.598,3893.93262,920.840,
2815.45239,608.598,3894.02417,921.840,
2815.54395,608.598,3894.11572,921.840,
2815.63550,608.598,3894.20728,921.840,
2815.72681,608.598,3894.29883,921.840,
2815.81836,608.598,3894.39038,921.840,
2815.90991,608.598,3894.48169,922.840,
2816.00146,609.598,3894.57324,922.840,
2816.09302,609.598,3894.66479,922.840,
2816.18457,610.598,3894.75635,923.840,
2816.27612,610.598,3894.84790,923.840,
2816.36743,611.598,3894.93945,923.840,
2816.45898,611.598,3895.03101,924.840,
2816.55054,612.598,3895.12256,923.840,
2816.64209,611.598,3895.21387,924.840,
2816.73364,612.598,3895.30542,924.840,
2816.82520,612.598,3895.39697,924.840,
2816.91675,612.598,3895.48853,924.840,
2817.00830,612.598,3895.58008,924.840,
2817.09961,612.598,3895.67163,925.840,
2817.19116,611.598,3895.76318,925.840,
2817.28271,611.598,3895.85449,925.840,
2817.37427,611.598,3895.94604,925.840,
2817.46582,611.598,3896.03760,926.840,
2817.55737,611.598,3896.12915,926.840,
2817.64893,611.598,3896.22070,926.840,
2817.74048,611.598,3896.31226,926.840,
2817.83179,611.598,3896.40381,926.840,
2817.92334,611.598,3896.49536,926.840,
2818.01489,611.598,3896.58667,927.840,
2818.10645,611.598,3896.67822,927.840,
2818.19800,611.598,3896.76978,927.840,
2818.28955,612.598,3896.86133,927.840,
2818.38110,611.598,3896.95288,927.840,
2818.47241,611.598,3897.04443,928.840,
2818.56396,611.598,3897.13599,929.840,
2818.65552,612.598,3897.22754,929.840,
2818.74707,611.598,3897.31885,929.840,
2818.83862,612.598,3897.41040,929.840,
2818.93018,612.598,3897.50195,930.840,
2819.02173,612.598,3897.59351,930.840,
2819.11328,612.598,3897.68506,929.840,
2819.20459,612.598,3897.77661,930.840,
2819.29614,613.598,3897.86816,931.840,
2819.38770,613.598,3897.95947,930.840,
2819.47925,613.598,3898.05103,931.840,
2819.57080,613.598,3898.14258,930.840,
2819.66235,613.598,3898.23413,930.840,
2819.75391,613.598,3898.32568,931.840,
2819.84546,614.598,3898.41724,931.840,
2819.93677,613.598,3898.50879,932.840,
2820.02832,614.598,3898.60034,931.840,
2820.11987,613.598,3898.69165,932.840,
2820.21143,614.598,3898.78320,931.840,
2820.30298,614.598,3898.87476,932.840,
2820.39453,614.598,3898.96631,933.840,
2820.48608,614.598,3899.05786,932.840,
2820.57739,614.598,3899.14941,932.840,
2820.66895,614.598,3899.24097,933.840,
2820.76050,615.598,3899.33252,933.840,
2820.85205,615.598,3899.42383,933.840,
2820.94360,615.598,3899.51538,933.840,
2821.03516,615.598,3899.60693,933.840,
2821.12671,615.598,3899.69849,934.840,
2821.21826,616.598,3899.79004,934.840,
2821.30957,616.598,3899.88159,934.840,
2821.40112,616.598,3899.97314,935.840,
2821.49268,616.598,3900.06445,935.840,
2821.58423,616.598,3900.15601,935.840,
2821.67578,616.598,3900.24756,935.840,
2821.76733,616.598,3900.33911,936.840,
2821.85889,616.598,3900.43066,936.840,
2821.95020,617.598,3900.52222,936.840,
2822.04175,617.598,3900.61377,936.840,
2822.13330,617.598,3900.70532,936.840,
2822.22485,617.598,3900.79663,936.840,
2822.31641,617.598,3900.88818,937.840,
2822.40796,617.598,3900.97974,937.840,
2822.49951,617.598,3901.07129,937.840,
2822.59106,618.598,3901.16284,937.840,
2822.68237,618.598,3901.25439,937.840,
2822.77393,618.598,3901.34595,937.840,
2822.86548,618.598,3901.43726,938.840,
2822.95703,618.598,3901.52881,938.840,
2823.04858,618.598,3901.62036,938.840,
2823.14014,618.598,3901.71191,938.840,
2823.23169,619.598,3901.80347,939.840,
2823.32324,618.598,3901.89502,939.840,
2823.41455,619.598,3901.98657,939.840,
2823.50610,619.598,3902.07813,940.840,
2823.59766,619.598,3902.16943,940.840,
2823.68921,619.598,3902.26099,940.840,
2823.78076,619.598,3902.35254,940.840,
2823.87231,620.598,3902.44409,940.840,
2823.96387,619.598,3902.53564,941.840,
2824.05518,620.598,3902.62720,941.840,
2824.14673,621.598,3902.71875,941.840,
2824.23828,620.598,3902.81030,941.840,
2824.32983,621.598,3902.90161,941.840,
2824.42139,621.598,3902.99316,942.840,
2824.51294,620.598,3903.08472,942.840,
2824.60449,621.598,3903.17627,942.840,
2824.69604,621.598,3903.26782,942.840,
2824.78735,621.598,3903.35938,943.840,
2824.87891,621.598,3903.45093,943.840,
2824.97046,621.598,3903.54224,943.840,
2825.06201,621.598,3903.63379,944.840,
2825.15356,621.598,3903.72534,943.840,
2825.24512,621.598,3903.81689,943.840,
2825.33667,622.598,3903.90845,944.840,
2825.42822,621.598,3904.00000,944.840,
2825.51953,622.598,3904.09155,944.840,
2825.61108,623.598,3904.18311,944.840,
2825.70264,622.598,3904.27441,944.840,
2825.79419,623.598,3904.36597,945.840,
2825.88574,622.598,3904.45752,945.840,
2825.97729,622.598,3904.54907,945.840,
2826.06885,622.598,3904.64063,946.840,
2826.16016,623.598,3904.73218,946.840,
2826.25171,623.598,3904.82373,946.840,
2826.34326,623.598,3904.91528,946.840,
2826.43481,623.598,3905.00659,947.840,
2826.52637,623.598,3905.09814,947.840,
2826.61792,624.598,3905.18970,947.840,
2826.70947,624.598,3905.28125,947.840,
2826.80103,624.598,3905.37280,947.840,
2826.89233,624.598,3905.46436,948.840,
2826.98389,624.598,3905.55591,948.840,
2827.07544,625.598,3905.64722,948.840,
2827.16699,624.598,3905.73877,948.840,
2827.25854,624.598,3905.83032,948.840,
2827.35010,624.598,3905.92188,948.840,
2827.44165,624.598,3906.01343,949.840,
2827.53296,625.598,3906.10498,949.840,
2827.62451,625.598,3906.19653,949.840,
2827.71606,625.598,3906.28809,950.840,
2827.80762,626.598,3906.37939,950.840,
2827.89917,625.598,3906.47095,949.840,
2827.99072,626.598,3906.56250,950.840,
2828.08228,626.598,3906.65405,950.840,
2828.17383,626.598,3906.74561,950.840,
2828.26514,626.598,3906.83716,951.840,
2828.35669,626.598,3906.92871,951.840,
2828.44824,626.598,3907.02002,951.840,
2828.53979,627.598,3907.11157,951.840,
2828.63135,626.598,3907.20313,952.840,
2828.72290,627.598,3907.29468,951.840,
2828.81445,627.598,3907.38623,952.840,
2828.90601,627.598,3907.47778,952.840,
2828.99731,627.598,3907.56934,952.840,
2829.08887,627.598,3907.66089,952.840,
2829.18042,627.598,3907.75220,954.840,
2829.27197,627.598,3907.84375,953.840,
2829.36353,627.598,3907.93530,953.840,
2829.45508,627.598,3908.02686,954.840,
2829.54663,627.598,3908.11841,954.840,
2829.63794,627.598,3908.20996,954.840,
2829.72949,628.598,3908.30151,954.840,
2829.82104,628.598,3908.39307,955.840,
2829.91260,628.598,3908.48438,954.840,
2830.00415,629.598,3908.57593,955.840,
2830.09570,628.598,3908.66748,955.840,
2830.18726,629.598,3908.75903,955.840,
2830.27881,629.598,3908.85059,955.840,
2830.37012,629.598,3908.94214,955.840,
2830.46167,629.598,3909.03369,956.840,
2830.55322,629.598,3909.12500,956.840,
2830.64478,629.598,3909.21655,957.840,
2830.73633,630.598,3909.30811,957.840,
2830.82788,630.598,3909.39966,957.840,
2830.91943,630.598,3909.49121,957.840,
2831.01099,629.598,3909.58276,957.840,
2831.10229,630.598,3909.67432,957.840,
2831.19385,630.598,3909.76587,957.840,
2831.28540,630.598,3909.85718,958.840,
2831.37695,630.598,3909.94873,958.840,
2831.46851,631.598,3910.04028,958.840,
2831.56006,631.598,3910.13184,958.840,
2831.65161,631.598,3910.22339,959.840,
2831.74292,631.598,3910.31494,958.840,
2831.83447,631.598,3910.40649,959.840,
2831.92603,631.598,3910.49805,959.840,
2832.01758,631.598,3910.58936,960.840,
2832.10913,632.598,3910.68091,960.840,
2832.20068,632.598,3910.77246,960.840,
2832.29224,632.598,3910.86401,960.840,
2832.38379,632.598,3910.95557,960.840,
2832.47510,632.598,3911.04712,961.840,
2832.56665,632.598,3911.13867,961.840,
2832.65820,633.598,3911.22998,961.840,
2832.74976,633.598,3911.32153,962.840,
2832.84131,633.598,3911.41309,962.840,
2832.93286,634.598,3911.50464,962.840,
2833.02441,633.598,3911.59619,962.840,
2833.11597,633.598,3911.68774,962.840,
2833.20728,633.598,3911.77930,962.840,
2833.29883,634.598,3911.87085,962.840,
2833.39038,633.598,3911.96216,963.840,
2833.48193,634.598,3912.05371,963.840,
2833.57349,634.598,3912.14526,962.840,
2833.66504,634.598,3912.23682,963.840,
2833.75659,633.598,3912.32837,963.840,
2833.84790,633.598,3912.41992,964.840,
2833.93945,633.598,3912.51147,964.840,
2834.03101,632.598,3912.60278,964.840,
2834.12256,631.598,3912.69434,964.840,
2834.21411,632.598,3912.78589,964.840,
2834.30566,632.598,3912.87744,965.840,
2834.39722,632.598,3912.96899,965.840,
2834.48877,632.598,3913.06055,965.840,
2834.58008,632.598,3913.15210,966.840,
2834.67163,632.598,3913.24365,966.840,
2834.76318,633.598,3913.33496,966.840,
2834.85474,633.598,3913.42651,966.840,
2834.94629,634.598,3913.51807,966.840,
2835.03784,634.598,3913.60962,967.840,
2835.12939,634.598,3913.70117,967.840,
2835.22070,634.598,3913.79272,967.840,
2835.31226,635.598,3913.88428,967.840,
2835.40381,635.598,3913.97583,968.840,
2835.49536,636.598,3914.06714,968.840,
2835.58691,636.598,3914.15869,968.840,
2835.67847,636.598,3914.25024,969.840,
2835.77002,637.598,3914.34180,968.840,
2835.86157,637.598,3914.43335,969.840,
2835.95288,637.598,3914.52490,969.840,
2836.04443,637.598,3914.61646,969.840,
2836.13599,637.598,3914.70776,969.840,
2836.22754,636.598,3914.79932,970.840,
2836.31909,637.598,3914.89087,970.840,
2836.41064,636.598,3914.98242,970.840,
2836.50220,636.598,3915.07397,971.840,
2836.59375,636.598,3915.16553,970.840,
2836.68506,636.598,3915.25708,970.840,
2836.77661,636.598,3915.34863,971.840,
2836.86816,636.598,3915.43994,971.840,
2836.95972,637.598,3915.53149,971.840,
2837.05127,637.598,3915.62305,972.840,
2837.14282,637.598,3915.71460,972.840,
2837.23438,638.598,3915.80615,972.840,
2837.32568,638.598,3915.89771,971.840,
2837.41724,638.598,3915.98926,972.840,
2837.50879,638.598,3916.08081,972.840,
2837.60034,639.598,3916.17212,973.840,
2837.69189,639.598,3916.26367,973.840,
2837.78345,639.598,3916.35522,973.840,
2837.87500,640.598,3916.44678,973.840,
2837.96655,640.598,3916.53833,974.840,
2838.05786,640.598,3916.62988,974.840,
2838.14941,640.598,3916.72144,974.840,
2838.24097,640.598,3916.81274,974.840,
2838.33252,641.598,3916.90430,974.840,
2838.42407,641.598,3916.99585,974.840,
2838.51563,641.598,3917.08740,975.840,
2838.60718,641.598,3917.17896,975.840,
2838.69873,641.598,3917.27051,975.840,
2838.79004,642.598,3917.36206,975.840,
2838.88159,641.598,3917.45361,975.840,
2838.97314,641.598,3917.54492,976.840,
2839.06470,641.598,3917.63647,976.840,
2839.15625,642.598,3917.72803,976.840,
2839.24780,642.598,3917.81958,977.840,
2839.33936,642.598,3917.91113,976.840,
2839.43066,642.598,3918.00269,977.840,
2839.52222,642.598,3918.09424,977.840,
2839.61377,643.598,3918.18579,977.840,
2839.70532,643.598,3918.27710,978.840,
2839.79688,643.598,3918.36865,979.840,
2839.88843,643.598,3918.46021,979.840,
2839.97998,643.598,3918.55176,979.840,
2840.07153,643.598,3918.64331,980.840,
2840.16284,643.598,3918.73486,980.840,
2840.25439,644.598,3918.82642,980.840,
2840.34595,644.598,3918.91772,981.840,
2840.43750,644.598,3919.00928,981.840,
2840.52905,644.598,3919.10083,981.840,
2840.62061,644.598,3919.19238,981.840,
2840.71216,644.598,3919.28394,982.840,
2840.80347,644.598,3919.37549,982.840,
2840.89502,645.598,3919.46704,983.840,
2840.98657,645.598,3919.55859,982.840,
2841.07813,645.598,3919.64990,982.840,
2841.16968,645.598,3919.74146,982.840,
2841.26123,645.598,3919.83301,982.840,
2841.35278,645.598,3919.92456,983.840,
2841.44434,645.598,3920.01611,982.840,
2841.53564,646.598,3920.10767,982.840,
2841.62720,645.598,3920.19922,983.840,
2841.71875,646.598,3920.29053,983.840,
2841.81030,646.598,3920.38208,983.840,
2841.90186,646.598,3920.47363,983.840,
2841.99341,646.598,3920.56519,983.840,
2842.08496,647.598,3920.65674,983.840,
2842.17651,647.598,3920.74829,983.840,
2842.26782,647.598,3920.83984,983.840,
2842.35938,648.598,3920.93140,984.840,
2842.45093,647.598,3921.02271,984.840,
2842.54248,647.598,3921.11426,984.840,
2842.63403,647.598,3921.20581,984.840,
2842.72559,648.598,3921.29736,985.840,
2842.81714,648.598,3921.38892,985.840,
2842.90845,648.598,3921.48047,985.840,
2843.00000,648.598,3921.57202,985.840,
2843.09155,648.598,3921.66357,985.840,
2843.18311,648.598,3921.75488,986.840,
2843.27466,648.598,3921.84644,986.840,
2843.36621,649.598,3921.93799,986.840,
2843.45776,649.598,3922.02954,987.840,
2843.54932,649.598,3922.12109,986.840,
2843.64063,649.598,3922.21265,987.840,
2843.73218,649.598,3922.30420,987.840,
2843.82373,649.598,3922.39551,988.840,
2843.91528,649.598,3922.48706,988.840,
2844.00684,649.598,3922.57861,987.840,
2844.09839,649.598,3922.67017,988.840,
2844.18994,650.598,3922.76172,988.840,
2844.28149,649.598,3922.85327,989.840,
2844.37280,650.598,3922.94482,988.840,
2844.46436,650.598,3923.03638,989.840,
2844.55591,650.598,3923.12769,989.840,
2844.64746,651.598,3923.21924,989.840,
2844.73901,651.598,3923.31079,989.840,
2844.83057,651.598,3923.40234,990.840,
2844.92212,651.598,3923.49390,990.840,
2845.01343,651.598,3923.58545,990.840,
2845.10498,651.598,3923.67700,990.840,
2845.19653,651.598,3923.76855,991.840,
2845.28809,651.598,3923.85986,991.840,
2845.37964,651.598,3923.95142,991.840,
2845.47119,651.598,3924.04297,991.840,
2845.56274,651.598,3924.13452,992.840,
2845.65430,652.598,3924.22607,992.840,
2845.74561,651.598,3924.31763,992.840,
2845.83716,652.598,3924.40918,992.840,
2845.92871,652.598,3924.50049,993.840,
2846.02026,653.598,3924.59204,993.840,
2846.11182,653.598,3924.68359,993.840,
2846.20337,652.598,3924.77515,993.840,
2846.29492,653.598,3924.86670,993.840,
2846.38623,653.598,3924.95825,993.840,
2846.47778,653.598,3925.04980,994.840,
2846.56934,653.598,3925.14136,994.840,
2846.66089,653.598,3925.23267,994.840,
2846.75244,653.598,3925.32422,995.840,
2846.84399,653.598,3925.41577,995.840,
2846.93555,653.598,3925.50732,994.840,
2847.02710,654.598,3925.59888,995.840,
2847.11841,654.598,3925.69043,995.840,
2847.20996,654.598,3925.78198,995.840,
2847.30151,655.598,3925.87329,995.840,
2847.39307,654.598,3925.96484,996.840,
2847.48462,654.598,3926.05640,996.840,
2847.57617,655.598,3926.14795,996.840,
2847.66772,655.598,3926.23950,997.840,
2847.75928,654.598,3926.33105,997.840,
2847.85059,655.598,3926.42261,997.840,
2847.94214,655.598,3926.51416,997.840,
2848.03369,656.598,3926.60547,997.840,
2848.12524,655.598,3926.69702,997.840,
2848.21680,656.598,3926.78857,998.840,
2848.30835,655.598,3926.88013,998.840,
2848.39990,656.598,3926.97168,998.840,
2848.49121,656.598,3927.06323,999.840,
2848.58276,656.598,3927.15479,999.840,
2848.67432,656.598,3927.24634,999.840,
2848.76587,656.598,3927.33765,999.840,
2848.85742,656.598,3927.42920,999.840,
2848.94897,656.598,3927.52075,1000.840,
2849.04053,658.598,3927.61230,1000.840,
2849.13208,657.598,3927.70386,1000.840,
2849.22339,657.598,3927.79541,1001.840,
2849.31494,657.598,3927.88696,1001.840,
2849.40649,657.598,3927.97827,1001.840,
2849.49805,657.598,3928.06982,1001.840,
2849.58960,658.598,3928.16138,1002.840,
2849.68115,658.598,3928.25293,1002.840,
2849.77271,658.598,3928.34448,1002.840,
2849.86426,657.598,3928.43604,1002.840,
2849.95557,658.598,3928.52759,1003.840,
2850.04712,658.598,3928.61914,1003.840,
2850.13867,659.598,3928.71045,1003.840,
2850.23022,659.598,3928.80200,1003.840,
2850.32178,659.598,3928.89355,1003.840,
2850.41333,659.598,3928.98511,1003.840,
2850.50488,659.598,3929.07666,1003.840,
2850.59619,659.598,3929.16821,1004.840,
2850.68774,659.598,3929.25977,1004.840,
2850.77930,659.598,3929.35132,1004.840,
2850.87085,659.598,3929.44263,1004.840,
2850.96240,660.598,3929.53418,1004.840,
2851.05396,660.598,3929.62573,1005.840,
2851.14551,660.598,3929.71729,1005.840,
2851.23706,660.598,3929.80884,1005.840,
2851.32837,660.598,3929.90039,1005.840,
2851.41992,660.598,3929.99194,1006.840,
2851.51147,660.598,3930.08325,1006.840,
2851.60303,661.598,3930.17480,1006.840,
2851.69458,661.598,3930.26636,1006.840,
2851.78613,661.598,3930.35791,1006.840,
2851.87769,661.598,3930.44946,1007.840,
2851.96924,661.598,3930.54102,1007.840,
2852.06055,661.598,3930.63257,1007.840,
2852.15210,662.598,3930.72412,1008.840,
2852.24365,662.598,3930.81543,1008.840,
2852.33521,662.598,3930.90698,1008.840,
2852.42676,662.598,3930.99854,1008.840,
2852.51831,663.598,3931.09009,1009.840,
2852.60986,662.598,3931.18164,1009.840,
2852.70117,662.598,3931.27319,1009.840,
2852.79272,663.598,3931.36475,1009.840,
2852.88428,663.598,3931.45605,1009.840,
2852.97583,663.598,3931.54761,1009.840,
2853.06738,663.598,3931.63916,1010.840,
2853.15894,663.598,3931.73071,1010.840,
2853.25049,663.598,3931.82227,1011.840,
2853.34204,663.598,3931.91382,1010.840,
2853.43335,664.598,3932.00537,1011.840,
2853.52490,664.598,3932.09692,1011.840,
2853.61646,664.598,3932.18823,1011.840,
2853.70801,664.598,3932.27979,1011.840,
2853.79956,664.598,3932.37134,1012.840,
2853.89111,664.598,3932.46289,1012.840,
2853.98267,665.598,3932.55444,1012.840,
2854.07397,665.598,3932.64600,1013.840,
2854.16553,665.598,3932.73755,1013.840,
2854.25708,665.598,3932.82910,1013.840,
2854.34863,665.598,3932.92041,1013.840,
2854.44019,665.598,3933.01196,1013.840,
2854.53174,665.598,3933.10352,1013.840,
2854.62329,665.598,3933.19507,1014.840,
2854.71484,666.598,3933.28662,1014.840,
2854.80615,665.598,3933.37817,1014.840,
2854.89771,666.598,3933.46973,1014.840,
2854.98926,666.598,3933.56104,1014.840,
2855.08081,666.598,3933.65259,1014.840,
2855.17236,666.598,3933.74414,1014.840,
2855.26392,666.598,3933.83569,1015.840,
2855.35547,667.598,3933.92725,1015.840,
2855.44702,666.598,3934.01880,1016.840,
2855.53833,668.598,3934.11035,1016.840,
2855.62988,667.598,3934.20190,1016.840,
2855.72144,667.598,3934.29321,1016.840,
2855.81299,667.598,3934.38477,1017.840,
2855.90454,666.598,3934.47632,1017.840,
2855.99609,666.598,3934.56787,1017.840,
2856.08765,666.598,3934.65942,1018.840,
2856.17896,666.598,3934.75098,1018.840,
2856.27051,666.598,3934.84253,1018.840,
2856.36206,667.598,3934.93408,1019.840,
2856.45361,667.598,3935.02539,1019.840,
2856.54517,667.598,3935.11694,1019.840,
2856.63672,667.598,3935.20850,1019.840,
2856.72827,667.598,3935.30005,1020.840,
2856.81982,668.598,3935.39160,1020.840,
2856.91113,668.598,3935.48315,1019.840,
2857.00269,668.598,3935.57471,1020.840,
2857.09424,669.598,3935.66602,1020.840,
2857.18579,668.598,3935.75757,1020.840,
2857.27734,668.598,3935.84912,1020.840,
2857.36890,669.598,3935.94067,1021.840,
2857.46045,669.598,3936.03223,1021.840,
2857.55200,669.598,3936.12378,1021.840,
2857.64331,670.598,3936.21533,1021.840,
2857.73486,669.598,3936.30688,1021.840,
2857.82642,670.598,3936.39819,1021.840,
2857.91797,670.598,3936.48975,1021.840,
2858.00952,671.598,3936.58130,1021.840,
2858.10107,670.598,3936.67285,1022.840,
2858.19263,671.598,3936.76440,1022.840,
2858.28394,671.598,3936.85596,1023.840,
2858.37549,671.598,3936.94751,1023.840,
2858.46704,672.598,3937.03906,1023.840,
2858.55859,671.598,3937.13037,1023.840,
2858.65015,671.598,3937.22192,1023.840,
2858.74170,671.598,3937.31348,1024.840,
2858.83325,671.598,3937.40503,1024.840,
2858.92480,672.598,3937.49658,1025.840,
2859.01611,672.598,3937.58813,1025.840,
2859.10767,672.598,3937.67969,1025.840,
2859.19922,672.598,3937.77100,1026.840,
2859.29077,673.598,3937.86255,1026.840,
2859.38232,673.598,3937.95410,1026.840,
2859.47388,673.598,3938.04565,1027.840,
2859.56543,673.598,3938.13721,1027.840,
2859.65674,673.598,3938.22876,1026.840,
2859.74829,674.598,3938.32031,1027.840,
2859.83984,673.598,3938.41187,1027.840,
2859.93140,673.598,3938.50317,1028.840,
2860.02295,674.598,3938.59473,1027.840,
2860.11450,673.598,3938.68628,1028.840,
2860.20605,673.598,3938.77783,1028.840,
2860.29761,674.598,3938.86938,1028.840,
2860.38892,674.598,3938.96094,1028.840,
2860.48047,675.598,3939.05249,1028.840,
2860.57202,674.598,3939.14380,1028.840,
2860.66357,674.598,3939.23535,1028.840,
2860.75513,675.598,3939.32690,1029.840,
2860.84668,675.598,3939.41846,1028.840,
2860.93823,675.598,3939.51001,1029.840,
2861.02979,675.598,3939.60156,1030.840,
2861.12109,675.598,3939.69312,1029.840,
2861.21265,675.598,3939.78467,1029.840,
2861.30420,675.598,3939.87598,1030.840,
2861.39575,676.598,3939.96753,1031.840,
2861.48730,676.598,3940.05908,1030.840,
2861.57886,675.598,3940.15063,1031.840,
2861.67041,676.598,3940.24219,1031.840,
2861.76172,676.598,3940.33374,1031.840,
2861.85327,676.598,3940.42529,1032.840,
2861.94482,676.598,3940.51685,1032.840,
2862.03638,676.598,3940.60815,1032.840,
2862.12793,676.598,3940.69971,1032.840,
2862.21948,677.598,3940.79126,1032.840,
2862.31104,676.598,3940.88281,1032.840,
2862.40259,677.598,3940.97437,1032.840,
2862.49390,677.598,3941.06592,1033.840,
2862.58545,677.598,3941.15747,1033.840,
2862.67700,677.598,3941.24878,1033.840,
2862.76855,677.598,3941.34033,1034.840,
2862.86011,678.598,3941.43188,1034.840,
2862.95166,678.598,3941.52344,1034.840,
2863.04321,677.598,3941.61499,1034.840,
2863.13477,678.598,3941.70654,1034.840,
2863.22607,679.598,3941.79810,1035.840,
2863.31763,678.598,3941.88965,1035.840,
2863.40918,678.598,3941.98096,1035.840,
2863.50073,679.598,3942.07251,1035.840,
2863.59229,679.598,3942.16406,1035.840,
2863.68384,680.598,3942.25562,1036.840,
2863.77539,679.598,3942.34717,1036.840,
2863.86670,679.598,3942.43872,1036.840,
2863.95825,680.598,3942.53027,1036.840,
2864.04980,679.598,3942.62183,1037.840,
2864.14136,680.598,3942.71313,1037.840,
2864.23291,679.598,3942.80469,1037.840,
2864.32446,680.598,3942.89624,1038.840,
2864.41602,680.598,3942.98779,1037.840,
2864.50757,680.598,3943.07935,1037.840,
2864.59888,680.598,3943.17090,1038.840,
2864.69043,681.598,3943.26245,1038.840,
2864.78198,680.598,3943.35376,1038.840,
2864.87354,680.598,3943.44531,1039.840,
2864.96509,681.598,3943.53687,1039.840,
2865.05664,681.598,3943.62842,1039.840,
2865.14819,682.598,3943.71997,1039.840,
2865.23950,681.598,3943.81152,1040.840,
2865.33105,681.598,3943.90308,1039.840,
2865.42261,681.598,3943.99463,1039.840,
2865.51416,682.598,3944.08594,1040.840,
2865.60571,682.598,3944.17749,1041.840,
2865.69727,682.598,3944.26904,1041.840,
2865.78882,682.598,3944.36060,1041.840,
2865.88037,683.598,3944.45215,1041.840,
2865.97168,682.598,3944.54370,1041.840,
2866.06323,682.598,3944.63525,1041.840,
2866.15479,683.598,3944.72656,1042.840,
2866.24634,683.598,3944.81812,1042.840,
2866.33789,683.598,3944.90967,1042.840,
2866.42944,683.598,3945.00122,1043.840,
2866.52100,683.598,3945.09277,1043.840,
2866.61255,684.598,3945.18433,1043.840,
2866.70386,684.598,3945.27588,1043.840,
2866.79541,684.598,3945.36743,1044.840,
2866.88696,684.598,3945.45874,1043.840,
2866.97852,684.598,3945.55029,1044.840,
2867.07007,684.598,3945.64185,1044.840,
2867.16162,684.598,3945.73340,1044.840,
2867.25317,685.598,3945.82495,1045.840,
2867.34448,685.598,3945.91650,1045.840,
2867.43604,684.598,3946.00806,1045.840,
2867.52759,685.598,3946.09961,1045.840,
2867.61914,685.598,3946.19092,1046.840,
2867.71069,684.598,3946.28247,1046.840,
2867.80225,685.598,3946.37402,1046.840,
2867.89380,685.598,3946.46558,1046.840,
2867.98535,686.598,3946.55713,1047.840,
2868.07666,686.598,3946.64868,1046.840,
2868.16821,686.598,3946.74023,1047.840,
2868.25977,686.598,3946.83154,1047.840,
2868.35132,686.598,3946.92310,1047.840,
2868.44287,686.598,3947.01465,1047.840,
2868.53442,686.598,3947.10620,1048.840,
2868.62598,686.598,3947.19775,1048.840,
2868.71753,687.598,3947.28931,1048.840,
2868.80884,687.598,3947.38086,1049.840,
2868.90039,687.598,3947.47241,1049.840,
2868.99194,687.598,3947.56372,1049.840,
2869.08350,687.598,3947.65527,1049.840,
2869.17505,687.598,3947.74683,1049.840,
2869.26660,688.598,3947.83838,1050.840,
2869.35815,687.598,3947.92993,1050.840,
2869.44946,687.598,3948.02148,1050.840,
2869.54102,688.598,3948.11304,1051.840,
2869.63257,688.598,3948.20459,1050.840,
2869.72412,688.598,3948.29590,1051.840,
2869.81567,689.598,3948.38745,1051.840,
2869.90723,688.598,3948.47900,1051.840,
2869.99878,689.598,3948.57056,1051.840,
2870.09033,689.598,3948.66211,1051.840,
2870.18164,689.598,3948.75366,1052.840,
2870.27319,689.598,3948.84521,1051.840,
2870.36475,689.598,3948.93652,1052.840,
2870.45630,689.598,3949.02808,1052.840,
2870.54785,690.598,3949.11963,1052.840,
2870.63940,690.598,3949.21118,1053.840,
2870.73096,690.598,3949.30273,1053.840,
2870.82251,690.598,3949.39429,1053.840,
2870.91382,690.598,3949.48584,1054.840,
2871.00537,690.598,3949.57739,1054.840,
2871.09692,690.598,3949.66870,1054.840,
2871.18848,691.598,3949.76025,1054.840,
2871.28003,690.598,3949.85181,1055.840,
2871.37158,690.598,3949.94336,1055.840,
2871.46313,690.598,3950.03491,1055.840,
2871.55444,691.598,3950.12646,1055.840,
2871.64600,691.598,3950.21802,1056.840,
2871.73755,691.598,3950.30933,1056.840,
2871.82910,691.598,3950.40088,1056.840,
2871.92065,691.598,3950.49243,1056.840,
2872.01221,691.598,3950.58398,1056.840,
2872.10376,692.598,3950.67554,1057.840,
2872.19531,692.598,3950.76709,1057.840,
2872.28662,692.598,3950.85864,1057.840,
2872.37817,692.598,3950.95020,1057.840,
2872.46973,693.598,3951.04150,1058.840,
2872.56128,694.598,3951.13306,1058.840,
2872.65283,695.598,3951.22461,1058.840,
2872.74438,695.598,3951.31616,1058.840,
2872.83594,695.598,3951.40771,1059.840,
2872.92725,696.598,3951.49927,1059.840,
2873.01880,696.598,3951.59082,1059.840,
2873.11035,697.598,3951.68237,1060.840,
2873.20190,697.598,3951.77368,1060.840,
2873.29346,697.598,3951.86523,1060.840,
2873.38501,696.598,3951.95679,1060.840,
2873.47656,696.598,3952.04834,1061.840,
2873.56812,696.598,3952.13989,1060.840,
2873.65942,696.598,3952.23145,1061.840,
2873.75098,696.598,3952.32300,1061.840,
2873.84253,696.598,3952.41431,1061.840,
2873.93408,696.598,3952.50586,1061.840,
2874.02563,696.598,3952.59741,1062.840,
2874.11719,696.598,3952.68896,1062.840,
2874.20874,696.598,3952.78052,1062.840,
2874.30029,696.598,3952.87207,1063.840,
2874.39160,696.598,3952.96362,1062.840,
2874.48315,696.598,3953.05518,1063.840,
2874.57471,696.598,3953.14648,1063.840,
2874.66626,697.598,3953.23804,1064.840,
2874.75781,696.598,3953.32959,1064.840,
2874.84937,696.598,3953.42114,1064.840,
2874.94092,696.598,3953.51270,1064.840,
2875.03223,696.598,3953.60425,1064.840,
2875.12378,695.598,3953.69580,1065.840,
2875.21533,694.598,3953.78735,1065.840,
2875.30688,695.598,3953.87866,1065.840,
2875.39844,695.598,3953.97021,1065.840,
2875.48999,694.598,3954.06177,1065.840,
2875.58154,695.598,3954.15332,1066.840,
2875.67310,695.598,3954.24487,1066.840,
2875.76440,695.598,3954.33643,1066.840,
2875.85596,696.598,3954.42798,1066.840,
2875.94751,696.598,3954.51929,1067.840,
2876.03906,696.598,3954.61084,1067.840,
2876.13062,696.598,3954.70239,1067.840,
2876.22217,697.598,3954.79395,1067.840,
2876.31372,696.598,3954.88550,1067.840,
2876.40527,697.598,3954.97705,1068.840,
2876.49658,698.598,3955.06860,1068.840,
2876.58813,698.598,3955.16016,1069.840,
2876.67969,698.598,3955.25146,1068.840,
2876.77124,698.598,3955.34302,1069.840,
2876.86279,700.598,3955.43457,1068.840,
2876.95435,699.598,3955.52612,1069.840,
2877.04590,699.598,3955.61768,1069.840,
2877.13721,699.598,3955.70923,1069.840,
2877.22876,700.598,3955.80078,1069.840,
2877.32031,700.598,3955.89233,1070.840,
2877.41187,700.598,3955.98364,1069.840,
2877.50342,700.598,3956.07520,1070.840,
2877.59497,700.598,3956.16675,1069.840,
2877.68652,700.598,3956.25830,1070.840,
2877.77808,702.598,3956.34985,1070.840,
2877.86938,701.598,3956.44141,1070.840,
2877.96094,701.598,3956.53296,1071.840,
2878.05249,701.598,3956.62427,1071.840,
2878.14404,702.598,3956.71582,1071.840,
2878.23560,701.598,3956.80737,1071.840,
2878.32715,702.598,3956.89893,1072.840,
2878.41870,702.598,3956.99048,1072.840,
2878.51001,702.598,3957.08203,1073.840,
2878.60156,702.598,3957.17358,1073.840,
2878.69312,703.598,3957.26514,1074.840,
2878.78467,702.598,3957.35645,1074.840,
2878.87622,703.598,3957.44800,1074.840,
2878.96777,703.598,3957.53955,1075.840,
2879.05933,703.598,3957.63110,1075.840,
2879.15088,703.598,3957.72266,1075.840,
2879.24219,703.598,3957.81421,1075.840,
2879.33374,703.598,3957.90576,1075.840,
2879.42529,704.598,3957.99707,1076.840,
2879.51685,703.598,3958.08862,1076.840,
2879.60840,704.598,3958.18018,1076.840,
2879.69995,703.598,3958.27173,1076.840,
2879.79150,705.598,3958.36328,1076.840,
2879.88306,704.598,3958.45483,1076.840,
2879.97437,705.598,3958.54639,1076.840,
2880.06592,704.598,3958.63794,1077.840,
2880.15747,705.598,3958.72925,1077.840,
2880.24902,705.598,3958.82080,1077.840,
2880.34058,706.598,3958.91235,1077.840,
2880.43213,705.598,3959.00391,1078.840,
2880.52368,705.598,3959.09546,1077.840,
2880.61499,706.598,3959.18701,1078.840,
2880.70654,705.598,3959.27856,1079.840,
2880.79810,705.598,3959.37012,1078.840,
2880.88965,706.598,3959.46143,1078.840,
2880.98120,706.598,3959.55298,1079.840,
2881.07275,705.598,3959.64453,1079.840,
2881.16431,706.598,3959.73608,1079.840,
2881.25586,707.598,3959.82764,1080.840,
2881.34717,707.598,3959.91919,1080.840,
2881.43872,707.598,3960.01074,1080.840,
2881.53027,707.598,3960.10205,1081.840,
2881.62183,707.598,3960.19360,1081.840,
2881.71338,707.598,3960.28516,1081.840,
2881.80493,707.598,3960.37671,1081.840,
2881.89648,707.598,3960.46826,1082.840,
2881.98804,708.598,3960.55981,1082.840,
2882.07935,708.598,3960.65137,1082.840,
2882.17090,708.598,3960.74292,1082.840,
2882.26245,708.598,3960.83423,1083.840,
2882.35400,708.598,3960.92578,1082.840,
2882.44556,709.598,3961.01733,1083.840,
2882.53711,709.598,3961.10889,1083.840,
2882.62866,709.598,3961.20044,1084.840,
2882.71997,709.598,3961.29199,1083.840,
2882.81152,709.598,3961.38354,1084.840,
2882.90308,709.598,3961.47510,1084.840,
2882.99463,709.598,3961.56641,1085.840,
2883.08618,709.598,3961.65796,1085.840,
2883.17773,709.598,3961.74951,1085.840,
2883.26929,709.598,3961.84106,1085.840,
2883.36084,710.598,3961.93262,1086.840,
2883.45215,710.598,3962.02417,1086.840,
2883.54370,710.598,3962.11572,1085.840,
2883.63525,710.598,3962.20703,1086.840,
2883.72681,710.598,3962.29858,1087.840,
2883.81836,711.598,3962.39014,1086.840,
2883.90991,711.598,3962.48169,1087.840,
2884.00146,711.598,3962.57324,1087.840,
2884.09277,711.598,3962.66479,1087.840,
2884.18433,712.598,3962.75635,1087.840,
2884.27588,711.598,3962.84790,1088.840,
2884.36743,711.598,3962.93921,1088.840,
2884.45898,712.598,3963.03076,1088.840,
2884.55054,712.598,3963.12231,1088.840,
2884.64209,712.598,3963.21387,1089.840,
2884.73364,712.598,3963.30542,1089.840,
2884.82495,712.598,3963.39697,1089.840,
2884.91650,713.598,3963.48853,1089.840,
2885.00806,713.598,3963.57983,1090.840,
2885.09961,713.598,3963.67139,1089.840,
2885.19116,713.598,3963.76294,1090.840,
2885.28271,713.598,3963.85449,1090.840,
2885.37427,713.598,3963.94604,1090.840,
2885.46582,713.598,3964.03760,1090.840,
2885.55713,713.598,3964.12915,1091.840,
2885.64868,715.598,3964.22070,1091.840,
2885.74023,714.598,3964.31201,1091.840,
2885.83179,714.598,3964.40356,1092.840,
2885.92334,714.598,3964.49512,1091.840,
2886.01489,714.598,3964.58667,1092.840,
2886.10645,715.598,3964.67822,1092.840,
2886.19775,715.598,3964.76978,1092.840,
2886.28931,715.598,3964.86133,1093.840,
2886.38086,715.598,3964.95288,1093.840,
2886.47241,715.598,3965.04419,1093.840,
2886.56396,715.598,3965.13574,1093.840,
2886.65552,715.598,3965.22729,1093.840,
2886.74707,715.598,3965.31885,1094.840,
2886.83862,715.598,3965.41040,1094.840,
2886.92993,716.598,3965.50195,1094.840,
2887.02148,716.598,3965.59351,1095.840,
2887.11304,716.598,3965.68481,1095.840,
2887.20459,716.598,3965.77637,1094.840,
2887.29614,716.598,3965.86792,1095.840,
2887.38770,716.598,3965.95947,1095.840,
2887.47925,717.598,3966.05103,1095.840,
2887.57080,716.598,3966.14258,1096.840,
2887.66211,716.598,3966.23413,1096.840,
2887.75366,717.598,3966.32568,1097.840,
2887.84521,717.598,3966.41699,1097.840,
2887.93677,717.598,3966.50854,1097.840,
2888.02832,717.598,3966.60010,1097.840,
2888.11987,717.598,3966.69165,1097.840,
2888.21143,717.598,3966.78320,1098.840,
2888.30273,718.598,3966.87476,1097.840,
2888.39429,718.598,3966.96631,1098.840,
2888.48584,718.598,3967.05786,1098.840,
2888.57739,718.598,3967.14917,1099.840,
2888.66895,719.598,3967.24072,1098.840,
2888.76050,719.598,3967.33228,1099.840,
2888.85205,719.598,3967.42383,1099.840,
2888.94360,719.598,3967.51538,1099.840,
2889.03491,720.598,3967.60693,1099.840,
2889.12646,719.598,3967.69849,1100.840,
2889.21802,719.598,3967.78979,1101.840,
2889.30957,720.598,3967.88135,1100.840,
2889.40112,720.598,3967.97290,1101.840,
2889.49268,720.598,3968.06445,1101.840,
2889.58423,720.598,3968.15601,1101.840,
2889.67578,720.598,3968.24756,1101.840,
2889.76709,720.598,3968.33911,1102.840,
2889.85864,720.598,3968.43066,1102.840,
2889.95020,721.598,3968.52197,1102.840,
2890.04175,721.598,3968.61353,1102.840,
2890.13330,721.598,3968.70508,1102.840,
2890.22485,721.598,3968.79663,1103.840,
2890.31641,722.598,3968.88818,1103.840,
2890.40771,722.598,3968.97974,1103.840,
2890.49927,722.598,3969.07129,1103.840,
2890.59082,722.598,3969.16260,1104.840,
2890.68237,722.598,3969.25415,1105.840,
2890.77393,722.598,3969.34570,1104.840,
2890.86548,722.598,3969.43726,1104.840,
2890.95703,722.598,3969.52881,1105.840,
2891.04858,722.598,3969.62036,1105.840,
2891.13989,723.598,3969.71191,1105.840,
2891.23145,723.598,3969.80347,1106.840,
2891.32300,723.598,3969.89478,1106.840,
2891.41455,723.598,3969.98633,1106.840,
2891.50610,723.598,3970.07788,1106.840,
2891.59766,723.598,3970.16943,1107.840,
2891.68921,724.598,3970.26099,1107.840,
2891.78052,724.598,3970.35254,1107.840,
2891.87207,724.598,3970.44409,1107.840,
2891.96362,725.598,3970.53564,1107.840,
2892.05518,725.598,3970.62695,1107.840,
2892.14673,726.598,3970.71851,1108.840,
2892.23828,726.598,3970.81006,1108.840,
2892.32983,726.598,3970.90161,1108.840,
2892.42139,726.598,3970.99316,1108.840,
2892.51270,726.598,3971.08472,1109.840,
2892.60425,727.598,3971.17627,1109.840,
2892.69580,726.598,3971.26758,1109.840,
2892.78735,726.598,3971.35913,1109.840,
2892.87891,727.598,3971.45068,1110.840,
2892.97046,727.598,3971.54224,1109.840,
2893.06201,727.598,3971.63379,1110.840,
2893.15356,727.598,3971.72534,1111.840,
2893.24487,727.598,3971.81689,1111.840,
2893.33643,727.598,3971.90845,1111.840,
2893.42798,727.598,3971.99976,1112.840,
2893.51953,727.598,3972.09131,1111.840,
2893.61108,727.598,3972.18286,1112.840,
2893.70264,727.598,3972.27441,1112.840,
2893.79419,727.598,3972.36597,1112.840,
2893.88550,727.598,3972.45752,1112.840,
2893.97705,728.598,3972.54907,1113.840,
2894.06860,728.598,3972.64063,1113.840,
2894.16016,729.598,3972.73193,1113.840,
2894.25171,730.598,3972.82349,1114.840,
2894.34326,730.598,3972.91504,1114.840,
2894.43481,731.598,3973.00659,1114.840,
2894.52637,731.598,3973.09814,1115.840,
2894.61768,731.598,3973.18970,1114.840,
2894.70923,731.598,3973.28125,1115.840,
2894.80078,731.598,3973.37256,1115.840,
2894.89233,731.598,3973.46411,1115.840,
2894.98389,731.598,3973.55566,1115.840,
2895.07544,731.598,3973.64722,1117.840,
2895.16699,730.598,3973.73877,1116.840,
2895.25854,730.598,3973.83032,1116.840,
2895.34985,730.598,3973.92188,1116.840,
2895.44141,730.598,3974.01343,1116.840,
2895.53296,730.598,3974.10474,1117.840,
2895.62451,730.598,3974.19629,1117.840,
2895.71606,730.598,3974.28784,1117.840,
2895.80762,730.598,3974.37939,1117.840,
2895.89917,731.598,3974.47095,1117.840,
2895.99048,731.598,3974.56250,1118.840,
2896.08203,731.598,3974.65405,1118.840,
2896.17358,730.598,3974.74536,1118.840,
2896.26514,731.598,3974.83691,1117.840,
2896.35669,731.598,3974.92847,1118.840,
2896.44824,731.598,3975.02002,1118.840,
2896.53979,731.598,3975.11157,1119.840,
2896.63135,732.598,3975.20313,1118.840,
2896.72266,732.598,3975.29468,1119.840,
2896.81421,732.598,3975.38623,1119.840,
2896.90576,732.598,3975.47754,1120.840,
2896.99731,733.598,3975.56909,1120.840,
2897.08887,732.598,3975.66064,1120.840,
2897.18042,733.598,3975.75220,1121.840,
2897.27197,733.598,3975.84375,1121.840,
2897.36328,733.598,3975.93530,1122.840,
2897.45483,733.598,3976.02686,1122.840,
2897.54639,733.598,3976.11841,1122.840,
2897.63794,733.598,3976.20972,1122.840,
2897.72949,734.598,3976.30127,1123.840,
2897.82104,734.598,3976.39282,1122.840,
2897.91260,734.598,3976.48438,1123.840,
2898.00415,734.598,3976.57593,1124.840,
2898.09546,735.598,3976.66748,1123.840,
2898.18701,735.598,3976.75903,1123.840,
2898.27856,735.598,3976.85034,1124.840,
2898.37012,735.598,3976.94189,1124.840,
2898.46167,735.598,3977.03345,1124.840,
2898.55322,735.598,3977.12500,1125.840,
2898.64478,735.598,3977.21655,1125.840,
2898.73633,736.598,3977.30811,1125.840,
2898.82764,736.598,3977.39966,1125.840,
2898.91919,736.598,3977.49121,1126.840,
2899.01074,736.598,3977.58252,1126.840,
2899.10229,736.598,3977.67407,1126.840,
2899.19385,736.598,3977.76563,1126.840,
2899.28540,737.598,3977.85718,1126.840,
2899.37695,737.598,3977.94873,1127.840,
2899.46826,737.598,3978.04028,1128.840,
2899.55981,737.598,3978.13184,1128.840,
2899.65137,737.598,3978.22339,1127.840,
2899.74292,737.598,3978.31470,1128.840,
2899.83447,738.598,3978.40625,1128.840,
2899.92603,737.598,3978.49780,1128.840,
2900.01758,738.598,3978.58936,1129.840,
2900.10913,738.598,3978.68091,1129.840,
2900.20044,738.598,3978.77246,1129.840,
2900.29199,739.598,3978.86401,1129.840,
2900.38354,738.598,3978.95532,1130.840,
2900.47510,739.598,3979.04688,1129.840,
2900.56665,739.598,3979.13843,1130.840,
2900.65820,739.598,3979.22998,1130.840,
2900.74976,739.598,3979.32153,1131.840,
2900.84131,739.598,3979.41309,1131.840,
2900.93262,739.598,3979.50464,1132.840,
2901.02417,739.598,3979.59619,1131.840,
2901.11572,740.598,3979.68750,1132.840,
2901.20728,740.598,3979.77905,1132.840,
2901.29883,740.598,3979.87061,1132.840,
2901.39038,740.598,3979.96216,1132.840,
2901.48193,741.598,3980.05371,1132.840,
2901.57324,740.598,3980.14526,1133.840,
2901.66479,741.598,3980.23682,1133.840,
2901.75635,741.598,3980.32837,1133.840,
2901.84790,741.598,3980.41968,1133.840,
2901.93945,741.598,3980.51123,1133.840,
2902.03101,742.598,3980.60278,1134.840,
2902.12256,742.598,3980.69434,1134.840,
2902.21411,741.598,3980.78589,1134.840,
2902.30542,741.598,3980.87744,1134.840,
2902.39697,742.598,3980.96899,1134.840,
2902.48853,742.598,3981.06030,1135.840,
2902.58008,742.598,3981.15186,1135.840,
2902.67163,742.598,3981.24341,1135.840,
2902.76318,742.598,3981.33496,1135.840,
2902.85474,742.598,3981.42651,1136.840,
2902.94604,743.598,3981.51807,1135.840,
2903.03760,743.598,3981.60962,1136.840,
2903.12915,743.598,3981.70117,1136.840,
2903.22070,744.598,3981.79248,1136.840,
2903.31226,743.598,3981.88403,1137.840,
2903.40381,743.598,3981.97559,1137.840,
2903.49536,744.598,3982.06714,1137.840,
2903.58691,744.598,3982.15869,1137.840,
2903.67822,744.598,3982.25024,1138.840,
2903.76978,744.598,3982.34180,1138.840,
2903.86133,744.598,3982.43311,1138.840,
2903.95288,744.598,3982.52466,1139.840,
2904.04443,745.598,3982.61621,1139.840,
2904.13599,745.598,3982.70776,1139.840,
2904.22754,745.598,3982.79932,1139.840,
2904.31909,745.598,3982.89087,1140.840,
2904.41040,745.598,3982.98242,1140.840,
2904.50195,746.598,3983.07397,1140.840,
2904.59351,745.598,3983.16528,1140.840,
2904.68506,746.598,3983.25684,1140.840,
2904.77661,746.598,3983.34839,1140.840,
2904.86816,746.598,3983.43994,1141.840,
2904.95972,746.598,3983.53149,1141.840,
2905.05103,747.598,3983.62305,1141.840,
2905.14258,747.598,3983.71460,1141.840,
2905.23413,747.598,3983.80615,1142.840,
2905.32568,747.598,3983.89746,1142.840,
2905.41724,747.598,3983.98901,1142.840,
2905.50879,747.598,3984.08057,1143.840,
2905.60034,747.598,3984.17212,1143.840,
2905.69189,747.598,3984.26367,1143.840,
2905.78320,747.598,3984.35522,1143.840,
2905.87476,748.598,3984.44678,1143.840,
2905.96631,748.598,3984.53809,1144.840,
2906.05786,748.598,3984.62964,1144.840,
2906.14941,749.598,3984.72119,1144.840,
2906.24097,749.598,3984.81274,1144.840,
2906.33252,749.598,3984.90430,1144.840,
2906.42407,749.598,3984.99585,1145.840,
2906.51538,749.598,3985.08740,1145.840,
2906.60693,749.598,3985.17896,1145.840,
2906.69849,749.598,3985.27026,1145.840,
2906.79004,749.598,3985.36182,1146.840,
2906.88159,750.598,3985.45337,1146.840,
2906.97314,750.598,3985.54492,1147.840,
2907.06470,750.598,3985.63647,1147.840,
2907.15601,750.598,3985.72803,1147.840,
2907.24756,750.598,3985.81958,1147.840,
2907.33911,751.598,3985.91113,1148.840,
2907.43066,751.598,3986.00244,1148.840,
2907.52222,750.598,3986.09399,1148.840,
2907.61377,751.598,3986.18555,1148.840,
2907.70532,751.598,3986.27710,1149.840,
2907.79688,751.598,3986.36865,1149.840,
2907.88818,752.598,3986.46021,1150.840,
2907.97974,751.598,3986.55176,1150.840,
2908.07129,752.598,3986.64307,1149.840,
2908.16284,752.598,3986.73462,1150.840,
2908.25439,752.598,3986.82617,1151.840,
2908.34595,752.598,3986.91772,1150.840,
2908.43750,753.598,3987.00928,1151.840,
2908.52905,753.598,3987.10083,1151.840,
2908.62036,753.598,3987.19238,1151.840,
2908.71191,753.598,3987.28394,1151.840,
2908.80347,753.598,3987.37524,1151.840,
2908.89502,753.598,3987.46680,1152.840,
2908.98657,754.598,3987.55835,1152.840,
2909.07813,754.598,3987.64990,1152.840,
2909.16968,754.598,3987.74146,1153.840,
2909.26099,754.598,3987.83301,1152.840,
2909.35254,754.598,3987.92456,1153.840,
2909.44409,754.598,3988.01587,1153.840,
2909.53564,754.598,3988.10742,1153.840,
2909.62720,754.598,3988.19897,1154.840,
2909.71875,755.598,3988.29053,1154.840,
2909.81030,755.598,3988.38208,1155.840,
2909.90186,755.598,3988.47363,1154.840,
2909.99316,755.598,3988.56519,1155.840,
2910.08472,755.598,3988.65674,1155.840,
2910.17627,755.598,3988.74805,1155.840,
2910.26782,756.598,3988.83960,1156.840,
2910.35938,756.598,3988.93115,1156.840,
2910.45093,755.598,3989.02271,1156.840,
2910.54248,757.598,3989.11426,1156.840,
2910.63379,756.598,3989.20581,1157.840,
2910.72534,756.598,3989.29736,1157.840,
2910.81689,756.598,3989.38892,1157.840,
2910.90845,755.598,3989.48022,1157.840,
2911.00000,755.598,3989.57178,1157.840,
2911.09155,754.598,3989.66333,1158.840,
2911.18311,754.598,3989.75488,1159.840,
2911.27466,754.598,3989.84644,1158.840,
2911.36597,754.598,3989.93799,1158.840,
2911.45752,754.598,3990.02954,1158.840,
2911.54907,754.598,3990.12085,1159.840,
2911.64063,755.598,3990.21240,1159.840,
2911.73218,755.598,3990.30396,1159.840,
2911.82373,756.598,3990.39551,1160.840,
2911.91528,756.598,3990.48706,1160.840,
2912.00684,756.598,3990.57861,1160.840,
2912.09814,757.598,3990.67017,1160.840,
2912.18970,757.598,3990.76172,1161.840,
2912.28125,757.598,3990.85303,1161.840,
2912.37280,758.598,3990.94458,1161.840,
2912.46436,758.598,3991.03613,1161.840,
2912.55591,759.598,3991.12769,1161.840,
2912.64746,760.598,3991.21924,1162.840,
2912.73877,759.598,3991.31079,1162.840,
2912.83032,759.598,3991.40234,1163.840,
2912.92188,760.598,3991.49390,1163.840,
2913.01343,760.598,3991.58521,1163.840,
2913.10498,760.598,3991.67676,1163.840,
2913.19653,761.598,3991.76831,1163.840,
2913.28809,760.598,3991.85986,1163.840,
2913.37964,760.598,3991.95142,1164.840,
2913.47095,761.598,3992.04297,1163.840,
2913.56250,760.598,3992.13452,1164.840,
2913.65405,761.598,3992.22583,1164.840,
2913.74561,761.598,3992.31738,1165.840,
2913.83716,761.598,3992.40894,1165.840,
2913.92871,762.598,3992.50049,1165.840,
2914.02026,762.598,3992.59204,1165.840,
2914.11182,763.598,3992.68359,1166.840,
2914.20313,763.598,3992.77515,1166.840,
2914.29468,763.598,3992.86670,1166.840,
2914.38623,763.598,3992.95801,1166.840,
2914.47778,763.598,3993.04956,1166.840,
2914.56934,763.598,3993.14111,1167.840,
2914.66089,764.598,3993.23267,1167.840,
2914.75244,764.598,3993.32422,1168.840,
2914.84375,764.598,3993.41577,1168.840,
2914.93530,765.598,3993.50732,1168.840,
2915.02686,764.598,3993.59863,1168.840,
2915.11841,765.598,3993.69019,1168.840,
2915.20996,765.598,3993.78174,1169.840,
2915.30151,765.598,3993.87329,1168.840,
2915.39307,765.598,3993.96484,1168.840,
2915.48462,765.598,3994.05640,1169.840,
2915.57593,765.598,3994.14795,1170.840,
2915.66748,765.598,3994.23950,1170.840,
2915.75903,766.598,3994.33081,1170.840,
2915.85059,765.598,3994.42236,1171.840,
2915.94214,765.598,3994.51392,1171.840,
2916.03369,766.598,3994.60547,1171.840,
2916.12524,766.598,3994.69702,1172.840,
2916.21655,766.598,3994.78857,1172.840,
2916.30811,766.598,3994.88013,1172.840,
2916.39966,767.598,3994.97168,1172.840,
2916.49121,766.598,3995.06299,1172.840,
2916.58276,766.598,3995.15454,1173.840,
2916.67432,767.598,3995.24609,1173.840,
2916.76587,767.598,3995.33765,1173.840,
2916.85742,767.598,3995.42920,1173.840,
2916.94873,768.598,3995.52075,1174.840,
2917.04028,768.598,3995.61230,1175.840,
2917.13184,767.598,3995.70361,1174.840,
2917.22339,768.598,3995.79517,1174.840,
2917.31494,768.598,3995.88672,1175.840,
2917.40649,768.598,3995.97827,1174.840,
2917.49805,768.598,3996.06982,1175.840,
2917.58960,768.598,3996.16138,1175.840,
2917.68091,768.598,3996.25293,1175.840,
2917.77246,769.598,3996.34448,1175.840,
2917.86401,769.598,3996.43579,1176.840,
2917.95557,769.598,3996.52734,1176.840,
2918.04712,769.598,3996.61890,1176.840,
2918.13867,769.598,3996.71045,1177.840,
2918.23022,770.598,3996.80200,1177.840,
2918.32153,770.598,3996.89355,1177.840,
2918.41309,770.598,3996.98511,1177.840,
2918.50464,770.598,3997.07666,1178.840,
2918.59619,770.598,3997.16797,1178.840,
2918.68774,770.598,3997.25952,1178.840,
2918.77930,771.598,3997.35107,1178.840,
2918.87085,771.598,3997.44263,1179.840,
2918.96240,771.598,3997.53418,1179.840,
2919.05371,771.598,3997.62573,1179.840,
2919.14526,771.598,3997.71729,1179.840,
2919.23682,771.598,3997.80859,1179.840,
2919.32837,772.598,3997.90015,1180.840,
2919.41992,772.598,3997.99170,1180.840,
2919.51147,772.598,3998.08325,1180.840,
2919.60303,771.598,3998.17480,1180.840,
2919.69458,772.598,3998.26636,1181.840,
2919.78589,772.598,3998.35791,1181.840,
2919.87744,772.598,3998.44946,1181.840,
2919.96899,773.598,3998.54077,1183.840,
2920.06055,773.598,3998.63232,1182.840,
2920.15210,773.598,3998.72388,1182.840,
2920.24365,773.598,3998.81543,1183.840,
2920.33521,773.598,3998.90698,1183.840,
2920.42651,773.598,3998.99854,1183.840,
2920.51807,774.598,3999.09009,1183.840,
2920.60962,774.598,3999.18164,1184.840,
2920.70117,774.598,3999.27295,1184.840,
2920.79272,775.598,3999.36450,1184.840,
2920.88428,774.598,3999.45605,1184.840,
2920.97583,775.598,3999.54761,1185.840,
2921.06738,775.598,3999.63916,1184.840,
2921.15869,775.598,3999.73071,1185.840,
2921.25024,775.598,3999.82227,1185.840,
2921.34180,775.598,3999.91357,1185.840,
2921.43335,775.598,4000.00513,1186.840,
2921.52490,775.598,4000.09668,1186.840,
2921.61646,776.598,4000.18823,1186.840,
2921.70801,776.598,4000.27979,1186.840,
2921.79932,776.598,4000.37134,1187.840,
2921.89087,777.598,4000.46289,1187.840,
2921.98242,776.598,4000.55444,1187.840,
2922.07397,776.598,4000.64575,1187.840,
2922.16553,777.598,4000.73730,1188.840,
2922.25708,777.598,4000.82886,1188.840,
2922.34863,777.598,4000.92041,1189.840,
2922.44019,777.598,4001.01196,1189.840,
2922.53149,777.598,4001.10352,1188.840,
2922.62305,777.598,4001.19507,1189.840,
2922.71460,778.598,4001.28638,1190.840,
2922.80615,779.598,4001.37793,1190.840,
2922.89771,778.598,4001.46948,1190.840,
2922.98926,778.598,4001.56104,1191.840,
2923.08081,778.598,4001.65259,1191.840,
2923.17236,778.598,4001.74414,1191.840,
2923.26367,779.598,4001.83569,1191.840,
2923.35522,779.598,4001.92725,1191.840,
2923.44678,779.598,4002.01855,1192.840,
2923.53833,778.598,4002.11011,1192.840,
2923.62988,779.598,4002.20166,1192.840,
2923.72144,780.598,4002.29321,1192.840,
2923.81299,779.598,4002.38477,1192.840,
2923.90430,779.598,4002.47632,1193.840,
2923.99585,780.598,4002.56787,1193.840,
2924.08740,780.598,4002.65942,1193.840,
2924.17896,780.598,4002.75073,1193.840,
2924.27051,780.598,4002.84229,1194.840,
2924.36206,780.598,4002.93384,1194.840,
2924.45361,780.598,4003.02539,1194.840,
2924.54517,781.598,4003.11694,1195.840,
2924.63647,781.598,4003.20850,1195.840,
2924.72803,781.598,4003.30005,1195.840,
2924.81958,781.598,4003.39136,1195.840,
2924.91113,781.598,4003.48291,1196.840,
2925.00269,781.598,4003.57446,1196.840,
2925.09424,781.598,4003.66602,1196.840,
2925.18579,782.598,4003.75757,1197.840,
2925.27734,782.598,4003.84912,1196.840,
2925.36865,782.598,4003.94067,1196.840,
2925.46021,782.598,4004.03223,1197.840,
2925.55176,783.598,4004.12354,1197.840,
2925.64331,783.598,4004.21509,1197.840,
2925.73486,783.598,4004.30664,1198.840,
2925.82642,783.598,4004.39819,1199.840,
2925.91797,783.598,4004.48975,1198.840,
2926.00928,784.598,4004.58130,1199.840,
2926.10083,784.598,4004.67285,1199.840,
2926.19238,784.598,4004.76440,1199.840,
2926.28394,784.598,4004.85571,1199.840,
2926.37549,784.598,4004.94727,1200.840,
2926.46704,785.598,4005.03882,1200.840,
2926.55859,784.598,4005.13037,1200.840,
2926.65015,785.598,4005.22192,1200.840,
2926.74146,784.598,4005.31348,1200.840,
2926.83301,785.598,4005.40503,1200.840,
2926.92456,785.598,4005.49634,1201.840,
2927.01611,785.598,4005.58789,1201.840,
2927.10767,785.598,4005.67944,1201.840,
2927.19922,785.598,4005.77100,1202.840,
2927.29077,785.598,4005.86255,1202.840,
2927.38208,785.598,4005.95410,1202.840,
2927.47363,785.598,4006.04565,1202.840,
2927.56519,786.598,4006.13721,1203.840,
2927.65674,786.598,4006.22852,1203.840,
2927.74829,786.598,4006.32007,1203.840,
2927.83984,786.598,4006.41162,1204.840,
2927.93140,786.598,4006.50317,1204.840,
2928.02295,787.598,4006.59473,1204.840,
2928.11426,787.598,4006.68628,1204.840,
2928.20581,787.598,4006.77783,1205.840,
2928.29736,787.598,4006.86914,1205.840,
2928.38892,787.598,4006.96069,1205.840,
2928.48047,788.598,4007.05225,1205.840,
2928.57202,788.598,4007.14380,1205.840,
2928.66357,788.598,4007.23535,1205.840,
2928.75513,788.598,4007.32690,1207.840,
2928.84644,789.598,4007.41846,1207.840,
2928.93799,788.598,4007.51001,1207.840,
2929.02954,789.598,4007.60132,1207.840,
2929.12109,789.598,4007.69287,1207.840,
2929.21265,789.598,4007.78442,1207.840,
2929.30420,789.598,4007.87598,1208.840,
2929.39575,789.598,4007.96753,1209.840,
2929.48706,790.598,4008.05908,1208.840,
2929.57861,790.598,4008.15063,1209.840,
2929.67017,790.598,4008.24219,1209.840,
2929.76172,791.598,4008.33350,1210.840,
2929.85327,791.598,4008.42505,1210.840,
2929.94482,792.598,4008.51660,1209.840,
2930.03638,793.598,4008.60815,1210.840,
2930.12793,793.598,4008.69971,1210.840,
2930.21924,793.598,4008.79126,1211.840,
2930.31079,793.598,4008.88281,1211.840,
2930.40234,793.598,4008.97412,1211.840,
2930.49390,793.598,4009.06567,1211.840,
2930.58545,794.598,4009.15723,1212.840,
2930.67700,793.598,4009.24878,1212.840,
2930.76855,794.598,4009.34033,1212.840,
2930.86011,794.598,4009.43188,1213.840,
2930.95142,794.598,4009.52344,1213.840,
2931.04297,794.598,4009.61499,1213.840,
2931.13452,793.598,4009.70630,1213.840,
2931.22607,794.598,4009.79785,1213.840,
2931.31763,794.598,4009.88940,1214.840,
2931.40918,794.598,4009.98096,1214.840,
2931.50073,794.598,4010.07251,1214.840,
2931.59204,794.598,4010.16406,1214.840,
2931.68359,794.598,4010.25562,1215.840,
2931.77515,794.598,4010.34717,1215.840,
2931.86670,794.598,4010.43848,1215.840,
2931.95825,794.598,4010.53003,1215.840,
2932.04980,794.598,4010.62158,1215.840,
2932.14136,793.598,4010.71313,1216.840,
2932.23291,794.598,4010.80469,1216.840,
2932.32422,794.598,4010.89624,1216.840,
2932.41577,794.598,4010.98779,1217.840,
2932.50732,795.598,4011.07910,1217.840,
2932.59888,794.598,4011.17065,1217.840,
2932.69043,793.598,4011.26221,1217.840,
2932.78198,794.598,4011.35376,1217.840,
2932.87354,794.598,4011.44531,1218.840,
2932.96509,794.598,4011.53687,1218.840,
2933.05640,795.598,4011.62842,1219.840,
2933.14795,795.598,4011.71997,1220.840,
2933.23950,795.598,4011.81128,1220.840,
2933.33105,795.598,4011.90283,1221.840,
2933.42261,795.598,4011.99438,1221.840,
2933.51416,795.598,4012.08594,1221.840,
2933.60571,796.598,4012.17749,1223.840,
2933.69702,796.598,4012.26904,1222.840,
2933.78857,796.598,4012.36060,1222.840,
2933.88013,796.598,4012.45190,1222.840,
2933.97168,797.598,4012.54346,1222.840,
2934.06323,797.598,4012.63501,1222.840,
2934.15479,797.598,4012.72656,1223.840,
2934.24634,798.598,4012.81812,1223.840,
2934.33789,798.598,4012.90967,1223.840,
2934.42920,798.598,4013.00122,1223.840,
2934.52075,798.598,4013.09277,1223.840,
2934.61230,799.598,4013.18408,1223.840,
2934.70386,799.598,4013.27563,1223.840,
2934.79541,799.598,4013.36719,1223.840,
2934.88696,799.598,4013.45874,1224.840,
2934.97852,800.598,4013.55029,1224.840,
2935.06982,799.598,4013.64185,1224.840,
2935.16138,799.598,4013.73340,1224.840,
2935.25293,800.598,4013.82495,1225.840,
2935.34448,800.598,4013.91626,1225.840,
2935.43604,801.598,4014.00781,1225.840,
2935.52759,800.598,4014.09937,1224.840,
2935.61914,801.598,4014.19092,1226.840,
2935.71069,801.598,4014.28247,1226.840,
2935.80200,801.598,4014.37402,1226.840,
2935.89355,801.598,4014.46558,1226.840,
2935.98511,801.598,4014.55688,1227.840,
2936.07666,801.598,4014.64844,1227.840,
2936.16821,802.598,4014.73999,1227.840,
2936.25977,801.598,4014.83154,1228.840,
2936.35132,801.598,4014.92310,1228.840,
2936.44287,802.598,4015.01465,1228.840,
2936.53418,802.598,4015.10620,1228.840,
2936.62573,802.598,4015.19775,1229.840,
2936.71729,802.598,4015.28906,1229.840,
2936.80884,803.598,4015.38062,1229.840,
2936.90039,803.598,4015.47217,1229.840,
2936.99194,803.598,4015.56372,1229.840,
2937.08350,803.598,4015.65527,1230.840,
2937.17480,803.598,4015.74683,1230.840,
2937.26636,804.598,4015.83838,1230.840,
2937.35791,804.598,4015.92993,1230.840,
2937.44946,803.598,4016.02124,1231.840,
2937.54102,804.598,4016.11279,1232.840,
2937.63257,804.598,4016.20435,1231.840,
2937.72412,804.598,4016.29590,1231.840,
2937.81567,804.598,4016.38745,1232.840,
2937.90698,804.598,4016.47900,1232.840,
2937.99854,804.598,4016.57056,1232.840,
2938.09009,805.598,4016.66187,1233.840,
2938.18164,805.598,4016.75342,1233.840,
2938.27319,805.598,4016.84497,1233.840,
2938.36475,806.598,4016.93652,1233.840,
2938.45630,806.598,4017.02808,1234.840,
2938.54785,806.598,4017.11963,1234.840,
2938.63916,805.598,4017.21118,1234.840,
2938.73071,806.598,4017.30273,1235.840,
2938.82227,807.598,4017.39404,1235.840,
2938.91382,807.598,4017.48560,1235.840,
2939.00537,806.598,4017.57715,1235.840,
2939.09692,807.598,4017.66870,1235.840,
2939.18848,807.598,4017.76025,1236.840,
2939.27979,807.598,4017.85181,1236.840,
2939.37134,807.598,4017.94336,1236.840,
2939.46289,807.598,4018.03491,1237.840,
2939.55444,808.598,4018.12622,1237.840,
2939.64600,807.598,4018.21777,1238.840,
2939.73755,808.598,4018.30933,1237.840,
2939.82910,808.598,4018.40088,1237.840,
2939.92065,808.598,4018.49243,1238.840,
2940.01196,808.598,4018.58398,1238.840,
2940.10352,809.598,4018.67554,1238.840,
2940.19507,809.598,4018.76685,1239.840,
2940.28662,809.598,4018.85840,1239.840,
2940.37817,809.598,4018.94995,1239.840,
2940.46973,809.598,4019.04150,1240.840,
2940.56128,809.598,4019.13306,1240.840,
2940.65259,809.598,4019.22461,1240.840,
2940.74414,809.598,4019.31616,1240.840,
2940.83569,809.598,4019.40771,1241.840,
2940.92725,809.598,4019.49902,1241.840,
2941.01880,810.598,4019.59058,1241.840,
2941.11035,810.598,4019.68213,1241.840,
2941.20190,810.598,4019.77368,1241.840,
2941.29346,811.598,4019.86523,1241.840,
2941.38477,811.598,4019.95679,1242.840,
2941.47632,811.598,4020.04834,1242.840,
2941.56787,811.598,4020.13965,1242.840,
2941.65942,811.598,4020.23120,1243.840,
2941.75098,811.598,4020.32275,1243.840,
2941.84253,811.598,4020.41431,1243.840,
2941.93408,811.598,4020.50586,1244.840,
2942.02563,812.598,4020.59741,1244.840,
2942.11694,812.598,4020.68896,1244.840,
2942.20850,812.598,4020.78052,1244.840,
2942.30005,812.598,4020.87183,1245.840,
2942.39160,813.598,4020.96338,1245.840,
2942.48315,813.598,4021.05493,1245.840,
2942.57471,813.598,4021.14648,1245.840,
2942.66626,813.598,4021.23804,1245.840,
2942.75757,814.598,4021.32959,1246.840,
2942.84912,813.598,4021.42114,1246.840,
2942.94067,814.598,4021.51270,1246.840,
2943.03223,814.598,4021.60400,1246.840,
2943.12378,814.598,4021.69556,1247.840,
2943.21533,814.598,4021.78711,1247.840,
2943.30688,814.598,4021.87866,1247.840,
2943.39844,814.598,4021.97021,1248.840,
2943.48975,815.598,4022.06177,1248.840,
2943.58130,815.598,4022.15332,1248.840,
2943.67285,815.598,4022.24463,1249.840,
2943.76440,815.598,4022.33618,1249.840,
2943.85596,815.598,4022.42773,1249.840,
2943.94751,815.598,4022.51929,1249.840,
2944.03906,816.598,4022.61084,1249.840,
2944.13062,815.598,4022.70239,1250.840,
2944.22192,816.598,4022.79395,1251.840,
2944.31348,816.598,4022.88550,1251.840,
2944.40503,816.598,4022.97681,1251.840,
2944.49658,816.598,4023.06836,1251.840,
2944.58813,817.598,4023.15991,1252.840,
2944.67969,816.598,4023.25146,1252.840,
2944.77124,817.598,4023.34302,1252.840,
2944.86255,817.598,4023.43457,1253.840,
2944.95410,817.598,4023.52612,1252.840,
2945.04565,817.598,4023.61768,1253.840,
2945.13721,817.598,4023.70898,1253.840,
2945.22876,817.598,4023.80054,1253.840,
2945.32031,817.598,4023.89209,1253.840,
2945.41187,818.598,4023.98364,1254.840,
2945.50342,818.598,4024.07520,1254.840,
2945.59473,818.598,4024.16675,1254.840,
2945.68628,819.598,4024.25830,1255.840,
2945.77783,819.598,4024.34961,1255.840,
2945.86938,819.598,4024.44116,1256.840,
2945.96094,819.598,4024.53271,1255.840,
2946.05249,819.598,4024.62427,1255.840,
2946.14404,819.598,4024.71582,1256.840,
2946.23535,819.598,4024.80737,1256.840,
2946.32690,820.598,4024.89893,1257.840,
2946.41846,820.598,4024.99048,1257.840,
2946.51001,820.598,4025.08179,1257.840,
2946.60156,820.598,4025.17334,1258.840,
2946.69312,820.598,4025.26489,1257.840,
2946.78467,820.598,4025.35645,1257.840,
2946.87622,820.598,4025.44800,1258.840,
2946.96753,820.598,4025.53955,1258.840,
2947.05908,821.598,4025.63110,1259.840,
2947.15063,822.598,4025.72241,1259.840,
2947.24219,821.598,4025.81396,1259.840,
2947.33374,821.598,4025.90552,1259.840,
2947.42529,822.598,4025.99707,1260.840,
2947.51685,821.598,4026.08862,1260.840,
2947.60840,821.598,4026.18018,1260.840,
2947.69971,822.598,4026.27173,1260.840,
2947.79126,822.598,4026.36328,1261.840,
2947.88281,822.598,4026.45459,1261.840,
2947.97437,823.598,4026.54614,1261.840,
2948.06592,823.598,4026.63770,1261.840,
2948.15747,823.598,4026.72925,1261.840,
2948.24902,823.598,4026.82080,1262.840,
2948.34033,824.598,4026.91235,1262.840,
2948.43188,824.598,4027.00391,1262.840,
2948.52344,824.598,4027.09546,1263.840,
2948.61499,825.598,4027.18677,1263.840,
2948.70654,825.598,4027.27832,1263.840,
2948.79810,824.598,4027.36987,1263.840,
2948.88965,825.598,4027.46143,1264.840,
2948.98120,825.598,4027.55298,1264.840,
2949.07251,825.598,4027.64453,1265.840,
2949.16406,825.598,4027.73608,1265.840,
2949.25562,825.598,4027.82739,1266.840,
2949.34717,825.598,4027.91895,1266.840,
2949.43872,825.598,4028.01050,1265.840,
2949.53027,826.598,4028.10205,1265.840,
2949.62183,825.598,4028.19360,1266.840,
2949.71338,825.598,4028.28516,1266.840,
2949.80469,826.598,4028.37671,1266.840,
2949.89624,826.598,4028.46826,1267.840,
2949.98779,826.598,4028.55957,1267.840,
2950.07935,827.598,4028.65112,1267.840,
2950.17090,827.598,4028.74268,1268.840,
2950.26245,826.598,4028.83423,1268.840,
2950.35400,826.598,4028.92578,1268.840,
2950.44531,825.598,4029.01733,1268.840,
2950.53687,825.598,4029.10889,1269.840,
2950.62842,824.598,4029.20044,1269.840,
2950.71997,824.598,4029.29175,1269.840,
2950.81152,824.598,4029.38330,1269.840,
2950.90308,823.598,4029.47485,1270.840,
2950.99463,824.598,4029.56641,1270.840,
2951.08618,824.598,4029.65796,1270.840,
2951.17749,825.598,4029.74951,1271.840,
2951.26904,825.598,4029.84106,1271.840,
2951.36060,826.598,4029.93237,1271.840,
2951.45215,826.598,4030.02393,1272.840,
2951.54370,827.598,4030.11548,1272.840,
2951.63525,827.598,4030.20703,1272.840,
2951.72681,828.598,4030.29858,1273.840,
2951.81836,828.598,4030.39014,1273.840,
2951.90967,828.598,4030.48169,1273.840,
2952.00122,829.598,4030.57324,1273.840,
2952.09277,829.598,4030.66455,1273.840,
2952.18433,830.598,4030.75610,1274.840,
2952.27588,829.598,4030.84766,1274.840,
2952.36743,830.598,4030.93921,1274.840,
2952.45898,831.598,4031.03076,1274.840,
2952.55029,831.598,4031.12231,1274.840,
2952.64185,831.598,4031.21387,1275.840,
2952.73340,831.598,4031.30518,1275.840,
2952.82495,832.598,4031.39673,1275.840,
2952.91650,832.598,4031.48828,1275.840,
2953.00806,832.598,4031.57983,1276.840,
2953.09961,832.598,4031.67139,1276.840,
2953.19116,832.598,4031.76294,1276.840,
2953.28247,833.598,4031.85449,1277.840,
2953.37402,833.598,4031.94604,1277.840,
2953.46558,833.598,4032.03735,1277.840,
2953.55713,833.598,4032.12891,1277.840,
2953.64868,833.598,4032.22046,1278.840,
2953.74023,834.598,4032.31201,1278.840,
2953.83179,833.598,4032.40356,1278.840,
2953.92310,833.598,4032.49512,1279.840,
2954.01465,834.598,4032.58667,1279.840,
2954.10620,834.598,4032.67822,1279.840,
2954.19775,834.598,4032.76953,1280.840,
2954.28931,834.598,4032.86108,1279.840,
2954.38086,835.598,4032.95264,1280.840,
2954.47241,835.598,4033.04419,1281.840,
2954.56396,835.598,4033.13574,1280.840,
2954.65527,835.598,4033.22729,1280.840,
2954.74683,836.598,4033.31885,1280.840,
2954.83838,836.598,4033.41016,1281.840,
2954.92993,836.598,4033.50171,1281.840,
2955.02148,836.598,4033.59326,1282.840,
2955.11304,836.598,4033.68481,1282.840,
2955.20459,836.598,4033.77637,1282.840,
2955.29614,836.598,4033.86792,1283.840,
2955.38745,836.598,4033.95947,1284.840,
2955.47900,836.598,4034.05103,1283.840,
2955.57056,837.598,4034.14233,1284.840,
2955.66211,837.598,4034.23389,1284.840,
2955.75366,837.598,4034.32544,1284.840,
2955.84521,837.598,4034.41699,1284.840,
2955.93677,838.598,4034.50854,1284.840,
2956.02808,837.598,4034.60010,1284.840,
2956.11963,838.598,4034.69165,1284.840,
2956.21118,838.598,4034.78320,1285.840,
2956.30273,839.598,4034.87451,1286.840,
2956.39429,839.598,4034.96606,1286.840,
2956.48584,839.598,4035.05762,1287.840,
2956.57739,839.598,4035.14917,1287.840,
2956.66895,839.598,4035.24072,1287.840,
2956.76025,839.598,4035.33228,1286.840,
2956.85181,839.598,4035.42383,1288.840,
2956.94336,839.598,4035.51514,1288.840,
2957.03491,840.598,4035.60669,1288.840,
2957.12646,840.598,4035.69824,1288.840,
2957.21802,840.598,4035.78979,1289.840,
2957.30957,840.598,4035.88135,1288.840,
2957.40112,840.598,4035.97290,1289.840,
2957.49243,841.598,4036.06445,1289.840,
2957.58398,840.598,4036.15601,1289.840,
2957.67554,841.598,4036.24731,1289.840,
2957.76709,841.598,4036.33887,1289.840,
2957.85864,841.598,4036.43042,1290.840,
2957.95020,841.598,4036.52197,1290.840,
2958.04175,841.598,4036.61353,1291.840,
2958.13306,841.598,4036.70508,1291.840,
2958.22461,841.598,4036.79663,1291.840,
2958.31616,842.598,4036.88818,1291.840,
2958.40771,842.598,4036.97949,1292.840,
2958.49927,842.598,4037.07104,1292.840,
2958.59082,842.598,4037.16260,1292.840,
2958.68237,843.598,4037.25415,1293.840,
2958.77393,842.598,4037.34570,1293.840,
2958.86523,843.598,4037.43726,1293.840,
2958.95679,843.598,4037.52881,1293.840,
2959.04834,843.598,4037.62012,1294.840,
2959.13989,843.598,4037.71167,1294.840,
2959.23145,843.598,4037.80322,1294.840,
2959.32300,843.598,4037.89478,1295.840,
2959.41455,844.598,4037.98633,1294.840,
2959.50586,844.598,4038.07788,1296.840,
2959.59741,844.598,4038.16943,1296.840,
2959.68896,844.598,4038.26099,1295.840,
2959.78052,844.598,4038.35229,1296.840,
2959.87207,844.598,4038.44385,1296.840,
2959.96362,844.598,4038.53540,1296.840,
2960.05518,844.598,4038.62695,1297.840,
2960.14673,845.598,4038.71851,1297.840,
2960.23804,845.598,4038.81006,1297.840,
2960.32959,846.598,4038.90161,1297.840,
2960.42114,846.598,4038.99292,1297.840,
2960.51270,845.598,4039.08447,1298.840,
2960.60425,846.598,4039.17603,1298.840,
2960.69580,846.598,4039.26758,1298.840,
2960.78735,847.598,4039.35913,1299.840,
2960.87891,847.598,4039.45068,1299.840,
2960.97021,847.598,4039.54224,1300.840,
2961.06177,847.598,4039.63379,1300.840,
2961.15332,847.598,4039.72510,1300.840,
2961.24487,847.598,4039.81665,1300.840,
2961.33643,848.598,4039.90820,1300.840,
2961.42798,848.598,4039.99976,1301.840,
2961.51953,848.598,4040.09131,1301.840,
2961.61084,848.598,4040.18286,1301.840,
2961.70239,848.598,4040.27441,1301.840,
2961.79395,849.598,4040.36597,1301.840,
2961.88550,848.598,4040.45728,1302.840,
2961.97705,849.598,4040.54883,1302.840,
2962.06860,849.598,4040.64038,1303.840,
2962.16016,849.598,4040.73193,1303.840,
2962.25171,849.598,4040.82349,1303.840,
2962.34302,849.598,4040.91504,1304.840,
2962.43457,849.598,4041.00659,1304.840,
2962.52612,850.598,4041.09790,1304.840,
2962.61768,850.598,4041.18945,1304.840,
2962.70923,850.598,4041.28101,1305.840,
2962.80078,850.598,4041.37256,1305.840,
2962.89233,850.598,4041.46411,1305.840,
2962.98389,850.598,4041.55566,1305.840,
2963.07520,851.598,4041.64722,1305.840,
2963.16675,851.598,4041.73877,1306.840,
2963.25830,851.598,4041.83008,1306.840,
2963.34985,851.598,4041.92163,1306.840,
2963.44141,852.598,4042.01318,1307.840,
2963.53296,852.598,4042.10474,1307.840,
2963.62451,852.598,4042.19629,1307.840,
2963.71582,852.598,4042.28784,1307.840,
2963.80737,853.598,4042.37939,1307.840,
2963.89893,852.598,4042.47095,1309.840,
2963.99048,852.598,4042.56226,1308.840,
2964.08203,853.598,4042.65381,1308.840,
2964.17358,853.598,4042.74536,1309.840,
2964.26514,853.598,4042.83691,1309.840,
2964.35669,853.598,4042.92847,1310.840,
2964.44800,853.598,4043.02002,1309.840,
2964.53955,853.598,4043.11157,1310.840,
2964.63110,853.598,4043.20288,1310.840,
2964.72266,854.598,4043.29443,1311.840,
2964.81421,854.598,4043.38599,1311.840,
2964.90576,854.598,4043.47754,1311.840,
2964.99731,854.598,4043.56909,1311.840,
2965.08862,855.598,4043.66064,1312.840,
2965.18018,855.598,4043.75220,1311.840,
2965.27173,855.598,4043.84375,1311.840,
2965.36328,855.598,4043.93506,1313.840,
2965.45483,855.598,4044.02661,1312.840,
2965.54639,855.598,4044.11816,1313.840,
2965.63794,856.598,4044.20972,1313.840,
2965.72949,855.598,4044.30127,1314.840,
2965.82080,856.598,4044.39282,1313.840,
2965.91235,856.598,4044.48438,1314.840,
2966.00391,856.598,4044.57568,1314.840,
2966.09546,857.598,4044.66724,1314.840,
2966.18701,858.598,4044.75879,1314.840,
2966.27856,858.598,4044.85034,1315.840,
2966.37012,858.598,4044.94189,1315.840,
2966.46167,859.598,4045.03345,1315.840,
2966.55298,860.598,4045.12500,1315.840,
2966.64453,860.598,4045.21655,1316.840,
2966.73608,860.598,4045.30786,1316.840,
2966.82764,861.598,4045.39941,1317.840,
2966.91919,861.598,4045.49097,1316.840,
2967.01074,861.598,4045.58252,1317.840,
2967.10229,861.598,4045.67407,1317.840,
2967.19360,861.598,4045.76563,1318.840,
2967.28516,861.598,4045.85718,1317.840,
2967.37671,862.598,4045.94873,1318.840,
2967.46826,861.598,4046.04004,1318.840,
2967.55981,861.598,4046.13159,1317.840,
2967.65137,861.598,4046.22314,1318.840,
2967.74292,861.598,4046.31470,1318.840,
2967.83447,861.598,4046.40625,1318.840,
2967.92578,860.598,4046.49780,1318.840,
2968.01733,861.598,4046.58936,1319.840,
2968.10889,861.598,4046.68066,1319.840,
2968.20044,861.598,4046.77222,1319.840,
2968.29199,861.598,4046.86377,1320.840,
2968.38354,861.598,4046.95532,1321.840,
2968.47510,861.598,4047.04688,1320.840,
2968.56665,860.598,4047.13843,1321.840,
2968.65796,859.598,4047.22998,1321.840,
2968.74951,859.598,4047.32153,1321.840,
2968.84106,858.598,4047.41284,1322.840,
2968.93262,858.598,4047.50439,1322.840,
2969.02417,858.598,4047.59595,1323.840,
2969.11572,858.598,4047.68750,1323.840,
2969.20728,858.598,4047.77905,1323.840,
2969.29858,859.598,4047.87061,1324.840,
2969.39014,859.598,4047.96216,1324.840,
2969.48169,859.598,4048.05371,1324.840,
2969.57324,860.598,4048.14502,1325.840,
2969.66479,860.598,4048.23657,1325.840,
2969.75635,860.598,4048.32813,1326.840,
2969.84790,861.598,4048.41968,1326.840,
2969.93945,861.598,4048.51123,1326.840,
2970.03076,861.598,4048.60278,1326.840,
2970.12231,862.598,4048.69434,1326.840,
2970.21387,863.598,4048.78564,1327.840,
2970.30542,863.598,4048.87720,1327.840,
2970.39697,864.598,4048.96875,1327.840,
2970.48853,864.598,4049.06030,1327.840,
2970.58008,865.598,4049.15186,1327.840,
2970.67163,865.598,4049.24341,1327.840,
2970.76294,865.598,4049.33496,1328.840,
2970.85449,865.598,4049.42651,1328.840,
2970.94604,865.598,4049.51782,1328.840,
2971.03760,866.598,4049.60938,1328.840,
2971.12915,866.598,4049.70093,1329.840,
2971.22070,866.598,4049.79248,1329.840,
2971.31226,867.598,4049.88403,1329.840,
2971.40356,867.598,4049.97559,1329.840,
2971.49512,867.598,4050.06714,1330.840,
2971.58667,867.598,4050.15845,1330.840,
2971.67822,867.598,4050.25000,1331.840,
2971.76978,867.598,4050.34155,1330.840,
2971.86133,867.598,4050.43311,1331.840,
2971.95288,867.598,4050.52466,1331.840,
2972.04443,868.598,4050.61621,1331.840,
2972.13574,868.598,4050.70776,1332.840,
2972.22729,868.598,4050.79932,1332.840,
2972.31885,868.598,4050.89063,1333.840,
2972.41040,868.598,4050.98218,1332.840,
2972.50195,869.598,4051.07373,1333.840,
2972.59351,869.598,4051.16528,1333.840,
2972.68506,869.598,4051.25684,1334.840,
2972.77637,869.598,4051.34839,1334.840,
2972.86792,869.598,4051.43994,1334.840,
2972.95947,869.598,4051.53149,1335.840,
2973.05103,870.598,4051.62280,1335.840,
2973.14258,869.598,4051.71436,1335.840,
2973.23413,870.598,4051.80591,1335.840,
2973.32568,870.598,4051.89746,1335.840,
2973.41724,870.598,4051.98901,1336.840,
2973.50854,871.598,4052.08057,1336.840,
2973.60010,871.598,4052.17212,1336.840,
2973.69165,871.598,4052.26343,1336.840,
2973.78320,872.598,4052.35498,1337.840,
2973.87476,871.598,4052.44653,1337.840,
2973.96631,871.598,4052.53809,1337.840,
2974.05786,871.598,4052.62964,1337.840,
2974.14941,872.598,4052.72119,1339.840,
2974.24072,872.598,4052.81274,1338.840,
2974.33228,872.598,4052.90430,1339.840,
2974.42383,872.598,4052.99561,1339.840,
2974.51538,873.598,4053.08716,1339.840,
2974.60693,873.598,4053.17871,1340.840,
2974.69849,873.598,4053.27026,1339.840,
2974.79004,873.598,4053.36182,1340.840,
2974.88135,873.598,4053.45337,1340.840,
2974.97290,874.598,4053.54492,1340.840,
2975.06445,874.598,4053.63647,1340.840,
2975.15601,874.598,4053.72778,1341.840,
2975.24756,874.598,4053.81934,1341.840,
2975.33911,874.598,4053.91089,1341.840,
2975.43066,874.598,4054.00244,1341.840,
2975.52222,875.598,4054.09399,1342.840,
2975.61353,875.598,4054.18555,1343.840,
2975.70508,875.598,4054.27710,1342.840,
2975.79663,875.598,4054.36841,1342.840,
2975.88818,875.598,4054.45996,1343.840,
2975.97974,875.598,4054.55151,1343.840,
2976.07129,875.598,4054.64307,1343.840,
2976.16284,875.598,4054.73462,1344.840,
2976.25439,876.598,4054.82617,1344.840,
2976.34570,876.598,4054.91772,1344.840,
2976.43726,877.598,4055.00928,1345.840,
2976.52881,877.598,4055.10059,1345.840,
2976.62036,877.598,4055.19214,1345.840,
2976.71191,877.598,4055.28369,1345.840,
2976.80347,877.598,4055.37524,1346.840,
2976.89502,877.598,4055.46680,1345.840,
2976.98633,878.598,4055.55835,1346.840,
2977.07788,878.598,4055.64990,1347.840,
2977.16943,878.598,4055.74146,1346.840,
2977.26099,878.598,4055.83276,1347.840,
2977.35254,878.598,4055.92432,1347.840,
2977.44409,878.598,4056.01587,1347.840,
2977.53564,878.598,4056.10742,1348.840,
2977.62720,878.598,4056.19897,1348.840,
2977.71851,879.598,4056.29053,1348.840,
2977.81006,879.598,4056.38208,1349.840,
2977.90161,879.598,4056.47339,1348.840,
2977.99316,879.598,4056.56494,1349.840,
2978.08472,879.598,4056.65649,1349.840,
2978.17627,879.598,4056.74805,1349.840,
2978.26782,880.598,4056.83960,1349.840,
2978.35913,880.598,4056.93115,1350.840,
2978.45068,880.598,4057.02271,1351.840,
2978.54224,880.598,4057.11426,1351.840,
2978.63379,880.598,4057.20557,1351.840,
2978.72534,880.598,4057.29712,1351.840,
2978.81689,881.598,4057.38867,1351.840,
2978.90845,881.598,4057.48022,1352.840,
2979.00000,881.598,4057.57178,1352.840,
2979.09131,882.598,4057.66333,1352.840,
2979.18286,881.598,4057.75488,1353.840,
2979.27441,882.598,4057.84619,1352.840,
2979.36597,882.598,4057.93774,1353.840,
2979.45752,882.598,4058.02930,1353.840,
2979.54907,882.598,4058.12085,1354.840,
2979.64063,882.598,4058.21240,1354.840,
2979.73218,883.598,4058.30396,1354.840,
2979.82349,883.598,4058.39551,1354.840,
2979.91504,883.598,4058.48706,1355.840,
2980.00659,883.598,4058.57837,1355.840,
2980.09814,883.598,4058.66992,1355.840,
2980.18970,883.598,4058.76147,1356.840,
2980.28125,884.598,4058.85303,1356.840,
2980.37280,883.598,4058.94458,1356.840,
2980.46411,884.598,4059.03613,1357.840,
2980.55566,884.598,4059.12769,1356.840,
2980.64722,884.598,4059.21924,1356.840,
2980.73877,884.598,4059.31055,1357.840,
2980.83032,885.598,4059.40210,1358.840,
2980.92188,885.598,4059.49365,1357.840,
2981.01343,885.598,4059.58521,1358.840,
2981.10498,885.598,4059.67676,1358.840,
2981.19629,885.598,4059.76831,1358.840,
2981.28784,885.598,4059.85986,1359.840,
2981.37939,886.598,4059.95117,1359.840,
2981.47095,886.598,4060.04272,1360.840,
2981.56250,886.598,4060.13428,1360.840,
2981.65405,886.598,4060.22583,1360.840,
2981.74561,887.598,4060.31738,1360.840,
2981.83716,887.598,4060.40894,1360.840,
2981.92847,887.598,4060.50049,1361.840,
2982.02002,887.598,4060.59204,1361.840,
2982.11157,887.598,4060.68335,1361.840,
2982.20313,887.598,4060.77490,1362.840,
2982.29468,888.598,4060.86646,1362.840,
2982.38623,888.598,4060.95801,1361.840,
2982.47778,888.598,4061.04956,1362.840,
2982.56909,888.598,4061.14111,1362.840,
2982.66064,889.598,4061.23267,1363.840,
2982.75220,888.598,4061.32422,1363.840,
2982.84375,889.598,4061.41553,1363.840,
2982.93530,889.598,4061.50708,1364.840,
2983.02686,889.598,4061.59863,1364.840,
2983.11841,889.598,4061.69019,1364.840,
2983.20996,889.598,4061.78174,1364.840,
2983.30127,889.598,4061.87329,1364.840,
2983.39282,890.598,4061.96484,1365.840,
2983.48438,890.598,4062.05615,1365.840,
2983.57593,890.598,4062.14771,1365.840,
2983.66748,890.598,4062.23926,1365.840,
2983.75903,891.598,4062.33081,1366.840,
2983.85059,891.598,4062.42236,1366.840,
2983.94189,891.598,4062.51392,1366.840,
2984.03345,891.598,4062.60547,1366.840,
2984.12500,892.598,4062.69702,1367.840,
2984.21655,892.598,4062.78833,1367.840,
2984.30811,893.598,4062.87988,1368.840,
2984.39966,894.598,4062.97144,1368.840,
2984.49121,895.598,4063.06299,1368.840,
2984.58276,895.598,4063.15454,1368.840,
2984.67407,895.598,4063.24609,1369.840,
2984.76563,896.598,4063.33765,1368.840,
2984.85718,896.598,4063.42896,1369.840,
2984.94873,895.598,4063.52051,1369.840,
2985.04028,896.598,4063.61206,1369.840,
2985.13184,896.598,4063.70361,1369.840,
2985.22339,896.598,4063.79517,1370.840,
2985.31494,896.598,4063.88672,1371.840,
2985.40625,896.598,4063.97827,1370.840,
2985.49780,895.598,4064.06982,1370.840,
2985.58936,896.598,4064.16113,1371.840,
2985.68091,895.598,4064.25269,1372.840,
2985.77246,895.598,4064.34424,1371.840,
2985.86401,896.598,4064.43579,1373.840,
2985.95557,895.598,4064.52734,1372.840,
2986.04688,896.598,4064.61890,1373.840,
2986.13843,895.598,4064.71045,1373.840,
2986.22998,896.598,4064.80200,1374.840,
2986.32153,895.598,4064.89331,1374.840,
2986.41309,895.598,4064.98486,1374.840,
2986.50464,895.598,4065.07642,1375.840,
2986.59619,894.598,4065.16797,1374.840,
2986.68774,894.598,4065.25952,1375.840,
2986.77905,893.598,4065.35107,1375.840,
2986.87061,894.598,4065.44263,1375.840,
2986.96216,893.598,4065.53394,1375.840,
2987.05371,893.598,4065.62549,1376.840,
2987.14526,894.598,4065.71704,1377.840,
2987.23682,894.598,4065.80859,1376.840,
2987.32837,894.598,4065.90015,1377.840,
2987.41992,895.598,4065.99170,1377.840,
2987.51123,895.598,4066.08325,1377.840,
2987.60278,895.598,4066.17480,1378.840,
2987.69434,895.598,4066.26611,1378.840,
2987.78589,896.598,4066.35767,1378.840,
2987.87744,896.598,4066.44922,1378.840,
2987.96899,896.598,4066.54077,1378.840,
2988.06055,897.598,4066.63232,1379.840,
2988.15186,898.598,4066.72388,1378.840,
2988.24341,898.598,4066.81543,1379.840,
2988.33496,899.598,4066.90698,1379.840,
2988.42651,899.598,4066.99829,1379.840,
2988.51807,899.598,4067.08984,1380.840,
2988.60962,899.598,4067.18140,1381.840,
2988.70117,900.598,4067.27295,1380.840,
2988.79272,900.598,4067.36450,1381.840,
2988.88403,900.598,4067.45605,1381.840,
2988.97559,901.598,4067.54761,1381.840,
2989.06714,901.598,4067.63892,1381.840,
2989.15869,901.598,4067.73047,1382.840,
2989.25024,901.598,4067.82202,1382.840,
2989.34180,902.598,4067.91357,1382.840,
2989.43335,902.598,4068.00513,1382.840,
2989.52490,902.598,4068.09668,1382.840,
2989.61621,903.598,4068.18823,1382.840,
2989.70776,902.598,4068.27979,1382.840,
2989.79932,903.598,4068.37109,1383.840,
2989.89087,903.598,4068.46265,1383.840,
2989.98242,903.598,4068.55420,1383.840,
2990.07397,903.598,4068.64575,1384.840,
2990.16553,903.598,4068.73730,1385.840,
2990.25684,903.598,4068.82886,1385.840,
2990.34839,903.598,4068.92041,1385.840,
2990.43994,903.598,4069.01172,1385.840,
2990.53149,903.598,4069.10327,1386.840,
2990.62305,904.598,4069.19482,1386.840,
2990.71460,904.598,4069.28638,1386.840,
2990.80615,905.598,4069.37793,1387.840,
2990.89771,905.598,4069.46948,1387.840,
2990.98901,905.598,4069.56104,1387.840,
2991.08057,905.598,4069.65259,1388.840,
2991.17212,905.598,4069.74390,1388.840,
2991.26367,905.598,4069.83545,1388.840,
2991.35522,906.598,4069.92700,1389.840,
2991.44678,906.598,4070.01855,1389.840,
2991.53833,906.598,4070.11011,1389.840,
2991.62964,906.598,4070.20166,1389.840,
2991.72119,907.598,4070.29321,1390.840,
2991.81274,907.598,4070.38477,1390.840,
2991.90430,907.598,4070.47607,1390.840,
2991.99585,907.598,4070.56763,1390.840,
2992.08740,907.598,4070.65918,1390.840,
2992.17896,907.598,4070.75073,1391.840,
2992.27051,907.598,4070.84229,1391.840,
2992.36182,907.598,4070.93384,1391.840,
2992.45337,907.598,4071.02539,1392.840,
2992.54492,908.598,4071.11670,1392.840,
2992.63647,908.598,4071.20825,1392.840,
2992.72803,908.598,4071.29980,1392.840,
2992.81958,908.598,4071.39136,1392.840,
2992.91113,908.598,4071.48291,1393.840,
2993.00269,909.598,4071.57446,1393.840,
2993.09399,909.598,4071.66602,1393.840,
2993.18555,909.598,4071.75757,1394.840,
2993.27710,909.598,4071.84888,1394.840,
2993.36865,909.598,4071.94043,1394.840,
2993.46021,909.598,4072.03198,1394.840,
2993.55176,909.598,4072.12354,1395.840,
2993.64331,910.598,4072.21509,1395.840,
2993.73462,910.598,4072.30664,1396.840,
2993.82617,911.598,4072.39819,1396.840,
2993.91772,911.598,4072.48975,1396.840,
2994.00928,911.598,4072.58105,1397.840,
2994.10083,911.598,4072.67261,1397.840,
2994.19238,911.598,4072.76416,1396.840,
2994.28394,911.598,4072.85571,1397.840,
2994.37549,912.598,4072.94727,1397.840,
2994.46680,912.598,4073.03882,1397.840,
2994.55835,912.598,4073.13037,1398.840,
2994.64990,912.598,4073.22168,1399.840,
2994.74146,912.598,4073.31323,1398.840,
2994.83301,912.598,4073.40479,1399.840,
2994.92456,912.598,4073.49634,1399.840,
2995.01611,912.598,4073.58789,1399.840,
2995.10767,913.598,4073.67944,1399.840,
2995.19897,913.598,4073.77100,1400.840,
2995.29053,912.598,4073.86255,1400.840,
2995.38208,913.598,4073.95386,1400.840,
2995.47363,914.598,4074.04541,1400.840,
2995.56519,914.598,4074.13696,1401.840,
2995.65674,914.598,4074.22852,1401.840,
2995.74829,914.598,4074.32007,1401.840,
2995.83960,915.598,4074.41162,1402.840,
2995.93115,914.598,4074.50317,1402.840,
2996.02271,915.598,4074.59448,1402.840,
2996.11426,915.598,4074.68604,1403.840,
2996.20581,915.598,4074.77759,1403.840,
2996.29736,915.598,4074.86914,1403.840,
2996.38892,915.598,4074.96069,1403.840,
2996.48047,916.598,4075.05225,1404.840,
2996.57178,916.598,4075.14380,1404.840,
2996.66333,916.598,4075.23535,1404.840,
2996.75488,916.598,4075.32666,1405.840,
2996.84644,916.598,4075.41821,1405.840,
2996.93799,917.598,4075.50977,1405.840,
2997.02954,917.598,4075.60132,1405.840,
2997.12109,917.598,4075.69287,1406.840,
2997.21240,917.598,4075.78442,1406.840,
2997.30396,918.598,4075.87598,1407.840,
2997.39551,918.598,4075.96753,1406.840,
2997.48706,918.598,4076.05884,1407.840,
2997.57861,918.598,4076.15039,1407.840,
2997.67017,918.598,4076.24194,1408.840,
2997.76172,918.598,4076.33350,1407.840,
2997.85327,918.598,4076.42505,1407.840,
2997.94458,919.598,4076.51660,1408.840,
2998.03613,919.598,4076.60815,1409.840,
2998.12769,919.598,4076.69946,1409.840,
2998.21924,918.598,4076.79102,1409.840,
2998.31079,919.598,4076.88257,1410.840,
2998.40234,920.598,4076.97412,1409.840,
2998.49390,920.598,4077.06567,1410.840,
2998.58545,920.598,4077.15723,1410.840,
2998.67676,920.598,4077.24878,1411.840,
2998.76831,920.598,4077.34033,1411.840,
2998.85986,921.598,4077.43164,1411.840,
2998.95142,921.598,4077.52319,1412.840,
2999.04297,921.598,4077.61475,1412.840,
2999.13452,921.598,4077.70630,1412.840,
2999.22607,921.598,4077.79785,1412.840,
2999.31738,921.598,4077.88940,1413.840,
2999.40894,921.598,4077.98096,1413.840,
2999.50049,921.598,4078.07251,1413.840,
2999.59204,921.598,4078.16382,1413.840,
2999.68359,922.598,4078.25537,1414.840,
2999.77515,922.598,4078.34692,1414.840,
2999.86670,923.598,4078.43848,1414.840,
2999.95825,923.598,4078.53003,1415.840,
3000.04956,923.598,4078.62158,1415.840,
3000.14111,923.598,4078.71313,1415.840,
3000.23267,923.598,4078.80444,1415.840,
3000.32422,924.598,4078.89600,1416.840,
3000.41577,924.598,4078.98755,1416.840,
3000.50732,924.598,4079.07910,1417.840,
3000.59888,925.598,4079.17065,1417.840,
3000.69043,924.598,4079.26221,1417.840,
3000.78174,925.598,4079.35376,1417.840,
3000.87329,925.598,4079.44531,1417.840,
3000.96484,925.598,4079.53662,1418.840,
3001.05640,925.598,4079.62817,1417.840,
3001.14795,925.598,4079.71973,1418.840,
3001.23950,926.598,4079.81128,1418.840,
3001.33105,926.598,4079.90283,1419.840,
3001.42236,926.598,4079.99438,1419.840,
3001.51392,926.598,4080.08594,1419.840,
3001.60547,926.598,4080.17749,1420.840,
3001.69702,926.598,4080.26880,1420.840,
3001.78857,927.598,4080.36035,1420.840,
3001.88013,926.598,4080.45190,1421.840,
3001.97168,926.598,4080.54346,1421.840,
3002.06323,926.598,4080.63501,1421.840,
3002.15454,925.598,4080.72656,1421.840,
3002.24609,925.598,4080.81812,1422.840,
3002.33765,925.598,4080.90942,1421.840,
3002.42920,925.598,4081.00098,1422.840,
3002.52075,925.598,4081.09253,1422.840,
3002.61230,925.598,4081.18408,1422.840,
3002.70386,925.598,4081.27563,1423.840,
3002.79517,926.598,4081.36719,1423.840,
3002.88672,925.598,4081.45874,1423.840,
3002.97827,926.598,4081.55029,1424.840,
3003.06982,926.598,4081.64160,1424.840,
3003.16138,927.598,4081.73315,1424.840,
3003.25293,927.598,4081.82471,1424.840,
3003.34448,928.598,4081.91626,1425.840,
3003.43604,928.598,4082.00781,1426.840,
3003.52734,928.598,4082.09937,1425.840,
3003.61890,929.598,4082.19092,1425.840,
3003.71045,930.598,4082.28223,1426.840,
3003.80200,929.598,4082.37378,1426.840,
3003.89355,930.598,4082.46533,1426.840,
3003.98511,930.598,4082.55688,1427.840,
3004.07666,930.598,4082.64844,1427.840,
3004.16821,931.598,4082.73999,1427.840,
3004.25952,932.598,4082.83154,1427.840,
3004.35107,932.598,4082.92310,1428.840,
3004.44263,933.598,4083.01440,1428.840,
3004.53418,934.598,4083.10596,1428.840,
3004.62573,935.598,4083.19751,1429.840,
3004.71729,935.598,4083.28906,1429.840,
3004.80884,936.598,4083.38062,1429.840,
3004.90015,936.598,4083.47217,1430.840,
3004.99170,936.598,4083.56372,1430.840,
3005.08325,936.598,4083.65527,1430.840,
3005.17480,936.598,4083.74658,1429.840,
3005.26636,936.598,4083.83813,1430.840,
3005.35791,936.598,4083.92969,1430.840,
3005.44946,936.598,4084.02124,1431.840,
3005.54102,936.598,4084.11279,1430.840,
3005.63232,936.598,4084.20435,1431.840,
3005.72388,936.598,4084.29590,1431.840,
3005.81543,936.598,4084.38721,1432.840,
3005.90698,936.598,4084.47876,1432.840,
3005.99854,936.598,4084.57031,1432.840,
3006.09009,936.598,4084.66187,1433.840,
3006.18164,936.598,4084.75342,1433.840,
3006.27319,936.598,4084.84497,1433.840,
3006.36450,936.598,4084.93652,1435.840,
3006.45605,936.598,4085.02808,1434.840,
3006.54761,936.598,4085.11938,1435.840,
3006.63916,936.598,4085.21094,1435.840,
3006.73071,936.598,4085.30249,1436.840,
3006.82227,937.598,4085.39404,1435.840,
3006.91382,937.598,4085.48560,1436.840,
3007.00513,937.598,4085.57715,1436.840,
3007.09668,937.598,4085.66870,1437.840,
3007.18823,938.598,4085.76025,1437.840,
3007.27979,938.598,4085.85156,1437.840,
3007.37134,937.598,4085.94312,1438.840,
3007.46289,938.598,4086.03467,1438.840,
3007.55444,938.598,4086.12622,1438.840,
3007.64600,938.598,4086.21777,1438.840,
3007.73730,938.598,4086.30933,1439.840,
3007.82886,938.598,4086.40088,1440.840,
3007.92041,939.598,4086.49219,1439.840,
3008.01196,939.598,4086.58374,1439.840,
3008.10352,939.598,4086.67529,1439.840,
3008.19507,940.598,4086.76685,1440.840,
3008.28662,939.598,4086.85840,1440.840,
3008.37793,939.598,4086.94995,1440.840,
3008.46948,940.598,4087.04150,1440.840,
3008.56104,940.598,4087.13306,1441.840,
3008.65259,940.598,4087.22437,1441.840,
3008.74414,940.598,4087.31592,1441.840,
3008.83569,941.598,4087.40747,1442.840,
3008.92725,940.598,4087.49902,1441.840,
3009.01880,941.598,4087.59058,1441.840,
3009.11011,941.598,4087.68213,1442.840,
3009.20166,941.598,4087.77368,1442.840,
3009.29321,942.598,4087.86499,1443.840,
3009.38477,942.598,4087.95654,1443.840,
3009.47632,942.598,4088.04810,1443.840,
3009.56787,942.598,4088.13965,1443.840,
3009.65942,942.598,4088.23120,1444.840,
3009.75098,943.598,4088.32275,1444.840,
3009.84229,943.598,4088.41431,1444.840,
3009.93384,943.598,4088.50586,1445.840,
3010.02539,943.598,4088.59717,1445.840,
3010.11694,944.598,4088.68872,1445.840,
3010.20850,943.598,4088.78027,1445.840,
3010.30005,944.598,4088.87183,1446.840,
3010.39160,944.598,4088.96338,1446.840,
3010.48291,945.598,4089.05493,1447.840,
3010.57446,944.598,4089.14648,1447.840,
3010.66602,945.598,4089.23804,1447.840,
3010.75757,945.598,4089.32935,1448.840,
3010.84912,945.598,4089.42090,1448.840,
3010.94067,945.598,4089.51245,1448.840,
3011.03223,945.598,4089.60400,1448.840,
3011.12378,945.598,4089.69556,1449.840,
3011.21509,946.598,4089.78711,1449.840,
3011.30664,945.598,4089.87866,1449.840,
3011.39819,946.598,4089.96997,1449.840,
3011.48975,946.598,4090.06152,1450.840,
3011.58130,947.598,4090.15308,1450.840,
3011.67285,946.598,4090.24463,1450.840,
3011.76440,947.598,4090.33618,1451.840,
3011.85596,947.598,4090.42773,1451.840,
3011.94727,947.598,4090.51929,1451.840,
3012.03882,948.598,4090.61084,1451.840,
3012.13037,947.598,4090.70215,1452.840,
3012.22192,948.598,4090.79370,1453.840,
3012.31348,948.598,4090.88525,1452.840,
3012.40503,948.598,4090.97681,1453.840,
3012.49658,948.598,4091.06836,1453.840,
3012.58789,949.598,4091.15991,1453.840,
3012.67944,949.598,4091.25146,1453.840,
3012.77100,949.598,4091.34302,1454.840,
3012.86255,949.598,4091.43433,1453.840,
3012.95410,950.598,4091.52588,1454.840,
3013.04565,950.598,4091.61743,1454.840,
3013.13721,950.598,4091.70898,1454.840,
3013.22876,950.598,4091.80054,1455.840,
3013.32007,951.598,4091.89209,1455.840,
3013.41162,951.598,4091.98364,1455.840,
3013.50317,951.598,4092.07495,1456.840,
3013.59473,951.598,4092.16650,1456.840,
3013.68628,951.598,4092.25806,1457.840,
3013.77783,951.598,4092.34961,1457.840,
3013.86938,951.598,4092.44116,1457.840,
3013.96094,951.598,4092.53271,1457.840,
3014.05225,951.598,4092.62427,1457.840,
3014.14380,952.598,4092.71582,1458.840,
3014.23535,952.598,4092.80713,1459.840,
3014.32690,951.598,4092.89868,1458.840,
3014.41846,952.598,4092.99023,1459.840,
3014.51001,953.598,4093.08179,1459.840,
3014.60156,953.598,4093.17334,1459.840,
3014.69287,953.598,4093.26489,1459.840,
3014.78442,954.598,4093.35645,1460.840,
3014.87598,953.598,4093.44775,1461.840,
3014.96753,954.598,4093.53931,1460.840,
3015.05908,954.598,4093.63086,1460.840,
3015.15063,954.598,4093.72241,1462.840,
3015.24219,954.598,4093.81396,1461.840,
3015.33374,954.598,4093.90552,1461.840,
3015.42505,955.598,4093.99707,1462.840,
3015.51660,955.598,4094.08862,1462.840,
3015.60815,955.598,4094.17993,1462.840,
3015.69971,955.598,4094.27148,1463.840,
3015.79126,955.598,4094.36304,1463.840,
3015.88281,955.598,4094.45459,1463.840,
3015.97437,956.598,4094.54614,1463.840,
3016.06567,956.598,4094.63770,1464.840,
3016.15723,956.598,4094.72925,1464.840,
3016.24878,957.598,4094.82080,1464.840,
3016.34033,956.598,4094.91211,1465.840,
3016.43188,956.598,4095.00366,1465.840,
3016.52344,956.598,4095.09521,1465.840,
3016.61499,957.598,4095.18677,1466.840,
3016.70654,957.598,4095.27832,1465.840,
3016.79785,957.598,4095.36987,1466.840,
3016.88940,957.598,4095.46143,1466.840,
3016.98096,958.598,4095.55273,1466.840,
3017.07251,958.598,4095.64429,1467.840,
3017.16406,958.598,4095.73584,1467.840,
3017.25562,959.598,4095.82739,1467.840,
3017.34717,958.598,4095.91895,1467.840,
3017.43872,959.598,4096.01025,1468.840,
3017.53003,959.598,4096.10205,1468.840,
3017.62158,959.598,4096.19336,1469.840,
3017.71313,960.598,4096.28516,1468.840,
3017.80469,960.598,4096.37646,1469.840,
3017.89624,960.598,4096.46826,1469.840,
3017.98779,960.598,4096.55957,1470.840,
3018.07935,960.598,4096.65088,1470.840,
3018.17065,960.598,4096.74268,1470.840,
3018.26221,960.598,4096.83398,1470.840,
3018.35376,960.598,4096.92578,1471.840,
3018.44531,961.598,4097.01709,1471.840,
3018.53687,961.598,4097.10889,1471.840,
3018.62842,961.598,4097.20020,1471.840,
3018.71997,961.598,4097.29150,1472.840,
3018.81152,961.598,4097.38330,1472.840,
3018.90283,962.598,4097.47461,1472.840,
3018.99438,962.598,4097.56641,1473.840,
3019.08594,961.598,4097.65771,1473.840,
3019.17749,962.598,4097.74951,1473.840,
3019.26904,963.598,4097.84082,1473.840,
3019.36060,963.598,4097.93262,1473.840,
3019.45215,963.598,4098.02393,1474.840,
3019.54370,963.598,4098.11523,1475.840,
3019.63501,963.598,4098.20703,1474.840,
3019.72656,964.598,4098.29834,1475.840,
3019.81812,963.598,4098.39014,1475.840,
3019.90967,964.598,4098.48145,1476.840,
3020.00122,964.598,4098.57324,1476.840,
3020.09277,965.598,4098.66455,1476.840,
3020.18433,964.598,4098.75586,1477.840,
3020.27563,965.598,4098.84766,1476.840,
3020.36719,966.598,4098.93896,1476.840,
3020.45874,966.598,4099.03076,1477.840,
3020.55029,966.598,4099.12207,1477.840,
3020.64185,966.598,4099.21387,1478.840,
3020.73340,966.598,4099.30518,1477.840,
3020.82495,966.598,4099.39648,1478.840,
3020.91650,966.598,4099.48828,1478.840,
3021.00781,967.598,4099.57959,1480.840,
3021.09937,967.598,4099.67139,1480.840,
3021.19092,967.598,4099.76270,1480.840,
3021.28247,967.598,4099.85449,1479.840,
3021.37402,967.598,4099.94580,1480.840,
3021.46558,967.598,4100.03760,1481.840,
3021.55713,967.598,4100.12891,1481.840,
3021.64844,967.598,4100.22021,1481.840,
3021.73999,967.598,4100.31201,1481.840,
3021.83154,969.598,4100.40332,1481.840,
3021.92310,968.598,4100.49512,1481.840,
3022.01465,969.598,4100.58643,1482.840,
3022.10620,970.598,4100.67822,1482.840,
3022.19775,970.598,4100.76953,1483.840,
3022.28931,971.598,4100.86084,1483.840,
3022.38062,971.598,4100.95264,1483.840,
3022.47217,972.598,4101.04395,1483.840,
3022.56372,972.598,4101.13574,1484.840,
3022.65527,972.598,4101.22705,1484.840,
3022.74683,972.598,4101.31885,1484.840,
3022.83838,972.598,4101.41016,1484.840,
3022.92993,973.598,4101.50146,1484.840,
3023.02148,973.598,4101.59326,1485.840,
3023.11279,973.598,4101.68457,1485.840,
3023.20435,974.598,4101.77637,1485.840,
3023.29590,974.598,4101.86768,1485.840,
3023.38745,974.598,4101.95947,1486.840,
3023.47900,973.598,4102.05078,1486.840,
3023.57056,974.598,4102.14258,1487.840,
3023.66211,974.598,4102.23389,1487.840,
3023.75342,973.598,4102.32520,1486.840,
3023.84497,973.598,4102.41699,1487.840,
3023.93652,974.598,4102.50830,1488.840,
3024.02808,973.598,4102.60010,1488.840,
3024.11963,973.598,4102.69141,1488.840,
3024.21118,974.598,4102.78320,1488.840,
3024.30273,974.598,4102.87451,1489.840,
3024.39429,974.598,4102.96582,1489.840,
3024.48560,974.598,4103.05762,1490.840,
3024.57715,974.598,4103.14893,1490.840,
3024.66870,974.598,4103.24072,1490.840,
3024.76025,975.598,4103.33203,1490.840,
3024.85181,975.598,4103.42383,1491.840,
3024.94336,975.598,4103.51514,1491.840,
3025.03491,975.598,4103.60645,1491.840,
3025.12646,975.598,4103.69824,1491.840,
3025.21777,975.598,4103.78955,1492.840,
3025.30933,975.598,4103.88135,1492.840,
3025.40088,976.598,4103.97266,1493.840,
3025.49243,977.598,4104.06445,1493.840,
3025.58398,976.598,4104.15576,1493.840,
3025.67554,977.598,4104.24756,1493.840,
3025.76709,977.598,4104.33887,1494.840,
3025.85840,977.598,4104.43018,1494.840,
3025.94995,977.598,4104.52197,1495.840,
3026.04150,977.598,4104.61328,1495.840,
3026.13306,977.598,4104.70508,1495.840,
3026.22461,977.598,4104.79639,1495.840,
3026.31616,978.598,4104.88818,1495.840,
3026.40771,978.598,4104.97949,1495.840,
3026.49927,978.598,4105.07080,1495.840,
3026.59058,979.598,4105.16260,1496.840,
3026.68213,978.598,4105.25391,1496.840,
3026.77368,979.598,4105.34570,1497.840,
3026.86523,979.598,4105.43701,1498.840,
3026.95679,979.598,4105.52881,1497.840,
3027.04834,979.598,4105.62012,1498.840,
3027.13989,979.598,4105.71143,1498.840,
3027.23120,980.598,4105.80322,1498.840,
3027.32275,979.598,4105.89453,1499.840,
3027.41431,980.598,4105.98633,1499.840,
3027.50586,980.598,4106.07764,1500.840,
3027.59741,980.598,4106.16943,1500.840,
3027.68896,981.598,4106.26074,1500.840,
3027.78052,981.598,4106.35254,1500.840,
3027.87207,981.598,4106.44385,1500.840,
3027.96338,981.598,4106.53516,1500.840,
3028.05493,981.598,4106.62695,1501.840,
3028.14648,982.598,4106.71826,1501.840,
3028.23804,982.598,4106.81006,1501.840,
3028.32959,983.598,4106.90137,1503.840,
3028.42114,982.598,4106.99316,1502.840,
3028.51270,982.598,4107.08447,1502.840,
3028.60425,982.598,4107.17578,1503.840,
3028.69556,983.598,4107.26758,1503.840,
3028.78711,984.598,4107.35889,1503.840,
3028.87866,983.598,4107.45068,1503.840,
3028.97021,983.598,4107.54199,1504.840,
3029.06177,983.598,4107.63379,1504.840,
3029.15332,984.598,4107.72510,1504.840,
3029.24487,984.598,4107.81641,1505.840,
3029.33618,984.598,4107.90820,1505.840,
3029.42773,984.598,4107.99951,1505.840,
3029.51929,984.598,4108.09131,1506.840,
3029.61084,984.598,4108.18262,1505.840,
3029.70239,985.598,4108.27441,1505.840,
3029.79395,985.598,4108.36572,1507.840,
3029.88550,985.598,4108.45752,1507.840,
3029.97705,985.598,4108.54883,1507.840,
3030.06836,986.598,4108.64014,1507.840,
3030.15991,986.598,4108.73193,1508.840,
3030.25146,986.598,4108.82324,1508.840,
3030.34302,986.598,4108.91504,1508.840,
3030.43457,986.598,4109.00635,1509.840,
3030.52612,987.598,4109.09814,1509.840,
3030.61768,988.598,4109.18945,1509.840,
3030.70923,987.598,4109.28076,1509.840,
3030.80054,987.598,4109.37256,1510.840,
3030.89209,988.598,4109.46387,1510.840,
3030.98364,987.598,4109.55566,1511.840,
3031.07520,988.598,4109.64697,1511.840,
3031.16675,988.598,4109.73877,1511.840,
3031.25830,988.598,4109.83008,1512.840,
3031.34985,989.598,4109.92139,1512.840,
3031.44116,988.598,4110.01318,1512.840,
3031.53271,989.598,4110.10449,1513.840,
3031.62427,989.598,4110.19629,1513.840,
3031.71582,989.598,4110.28760,1513.840,
3031.80737,989.598,4110.37939,1513.840,
3031.89893,990.598,4110.47070,1513.840,
3031.99048,990.598,4110.56201,1514.840,
3032.08203,991.598,4110.65381,1514.840,
3032.17334,990.598,4110.74512,1514.840,
3032.26489,990.598,4110.83691,1515.840,
3032.35645,991.598,4110.92822,1515.840,
3032.44800,991.598,4111.02002,1515.840,
3032.53955,991.598,4111.11133,1516.840,
3032.63110,991.598,4111.20313,1516.840,
3032.72266,992.598,4111.29443,1517.840,
3032.81421,991.598,4111.38574,1516.840,
3032.90552,992.598,4111.47754,1517.840,
3032.99707,992.598,4111.56885,1517.840,
3033.08862,992.598,4111.66064,1517.840,
3033.18018,993.598,4111.75195,1518.840,
3033.27173,993.598,4111.84375,1518.840,
3033.36328,992.598,4111.93506,1518.840,
3033.45483,993.598,4112.02637,1518.840,
3033.54614,994.598,4112.11816,1519.840,
3033.63770,993.598,4112.20947,1519.840,
3033.72925,994.598,4112.30127,1519.840,
3033.82080,994.598,4112.39258,1519.840,
3033.91235,994.598,4112.48438,1520.840,
3034.00391,994.598,4112.57568,1520.840,
3034.09546,994.598,4112.66699,1521.840,
3034.18701,995.598,4112.75879,1522.840,
3034.27832,995.598,4112.85010,1521.840,
3034.36987,995.598,4112.94189,1521.840,
3034.46143,995.598,4113.03320,1521.840,
3034.55298,996.598,4113.12500,1522.840,
3034.64453,995.598,4113.21631,1522.840,
3034.73608,996.598,4113.30811,1523.840,
3034.82764,997.598,4113.39941,1522.840,
3034.91895,996.598,4113.49072,1523.840,
3035.01050,996.598,4113.58252,1523.840,
3035.10205,997.598,4113.67383,1524.840,
3035.19360,997.598,4113.76563,1523.840,
3035.28516,997.598,4113.85693,1524.840,
3035.37671,998.598,4113.94873,1524.840,
3035.46826,998.598,4114.04004,1524.840,
3035.55981,998.598,4114.13135,1525.840,
3035.65112,998.598,4114.22314,1526.840,
3035.74268,998.598,4114.31445,1525.840,
3035.83423,998.598,4114.40625,1526.840,
3035.92578,998.598,4114.49756,1526.840,
3036.01733,999.598,4114.58936,1526.840,
3036.10889,999.598,4114.68066,1527.840,
3036.20044,999.598,4114.77197,1527.840,
3036.29199,999.598,4114.86377,1527.840,
3036.38330,999.598,4114.95508,1527.840,
3036.47485,1000.598,4115.04688,1528.840,
3036.56641,1000.598,4115.13818,1528.840,
3036.65796,1000.598,4115.22998,1528.840,
3036.74951,1000.598,4115.32129,1529.840,
3036.84106,1000.598,4115.41309,1529.840,
3036.93262,1001.598,4115.50439,1529.840,
3037.02393,1001.598,4115.59570,1530.840,
3037.11548,1001.598,4115.68750,1530.840,
3037.20703,1002.598,4115.77881,1530.840,
3037.29858,1003.598,4115.87061,1531.840,
3037.39014,1003.598,4115.96191,1531.840,
3037.48169,1004.598,4116.05371,1531.840,
3037.57324,1005.598,4116.14502,1531.840,
3037.66479,1005.598,4116.23633,1532.840,
3037.75610,1006.598,4116.32813,1532.840,
3037.84766,1006.598,4116.41943,1532.840,
3037.93921,1007.598,4116.51123,1532.840,
3038.03076,1006.598,4116.60254,1533.840,
3038.12231,1007.598,4116.69434,1533.840,
3038.21387,1007.598,4116.78564,1533.840,
3038.30542,1006.598,4116.87695,1533.840,
3038.39697,1006.598,4116.96875,1534.840,
3038.48828,1006.598,4117.06006,1534.840,
3038.57983,1006.598,4117.15186,1535.840,
3038.67139,1006.598,4117.24316,1535.840,
3038.76294,1006.598,4117.33496,1535.840,
3038.85449,1005.598,4117.42627,1535.840,
3038.94604,1005.598,4117.51807,1536.840,
3039.03760,1006.598,4117.60938,1536.840,
3039.12891,1006.598,4117.70068,1537.840,
3039.22046,1006.598,4117.79248,1537.840,
3039.31201,1006.598,4117.88379,1537.840,
3039.40356,1007.598,4117.97559,1537.840,
3039.49512,1006.598,4118.06689,1537.840,
3039.58667,1006.598,4118.15869,1538.840,
3039.67822,1005.598,4118.25000,1538.840,
3039.76978,1005.598,4118.34131,1539.840,
3039.86108,1005.598,4118.43311,1539.840,
3039.95264,1005.598,4118.52441,1539.840,
3040.04419,1006.598,4118.61621,1539.840,
3040.13574,1006.598,4118.70752,1540.840,
3040.22729,1006.598,4118.79932,1540.840,
3040.31885,1006.598,4118.89063,1540.840,
3040.41040,1007.598,4118.98193,1540.840,
3040.50171,1007.598,4119.07373,1540.840,
3040.59326,1007.598,4119.16504,1541.840,
3040.68481,1007.598,4119.25684,1542.840,
3040.77637,1007.598,4119.34814,1541.840,
3040.86792,1008.598,4119.43994,1542.840,
3040.95947,1008.598,4119.53125,1542.840,
3041.05103,1009.598,4119.62305,1542.840,
3041.14258,1009.598,4119.71436,1542.840,
3041.23389,1009.598,4119.80566,1543.840,
3041.32544,1010.598,4119.89746,1543.840,
3041.41699,1009.598,4119.98877,1544.840,
3041.50854,1010.598,4120.08057,1544.840,
3041.60010,1010.598,4120.17188,1544.840,
3041.69165,1010.598,4120.26367,1545.840,
3041.78320,1011.598,4120.35498,1545.840,
3041.87476,1011.598,4120.44629,1545.840,
3041.96606,1011.598,4120.53809,1546.840,
3042.05762,1012.598,4120.62939,1546.840,
3042.14917,1012.598,4120.72119,1546.840,
3042.24072,1012.598,4120.81250,1547.840,
3042.33228,1012.598,4120.90430,1547.840,
3042.42383,1013.598,4120.99561,1547.840,
3042.51538,1012.598,4121.08691,1547.840,
3042.60669,1013.598,4121.17871,1548.840,
3042.69824,1013.598,4121.27002,1548.840,
3042.78979,1013.598,4121.36182,1548.840,
3042.88135,1013.598,4121.45313,1548.840,
3042.97290,1013.598,4121.54492,1549.840,
3043.06445,1014.598,4121.63623,1549.840,
3043.15601,1014.598,4121.72754,1549.840,
3043.24756,1014.598,4121.81934,1550.840,
3043.33887,1014.598,4121.91064,1550.840,
3043.43042,1014.598,4122.00244,1550.840,
3043.52197,1015.598,4122.09375,1551.840,
3043.61353,1015.598,4122.18555,1551.840,
3043.70508,1015.598,4122.27686,1551.840,
3043.79663,1015.598,4122.36865,1551.840,
3043.88818,1015.598,4122.45996,1551.840,
3043.97974,1016.598,4122.55127,1552.840,
3044.07104,1016.598,4122.64307,1552.840,
3044.16260,1016.598,4122.73438,1552.840,
3044.25415,1017.598,4122.82617,1553.840,
3044.34570,1017.598,4122.91748,1553.840,
3044.43726,1017.598,4123.00928,1553.840,
3044.52881,1017.598,4123.10059,1553.840,
3044.62036,1017.598,4123.19189,1553.840,
3044.71167,1018.598,4123.28369,1553.840,
3044.80322,1018.598,4123.37500,1553.840,
3044.89478,1017.598,4123.46680,1554.840,
3044.98633,1018.598,4123.55811,1554.840,
3045.07788,1018.598,4123.64990,1555.840,
3045.16943,1019.598,4123.74121,1555.840,
3045.26099,1019.598,4123.83252,1555.840,
3045.35254,1019.598,4123.92432,1556.840,
3045.44385,1019.598,4124.01563,1556.840,
3045.53540,1019.598,4124.10742,1556.840,
3045.62695,1019.598,4124.19873,1557.840,
3045.71851,1019.598,4124.29053,1557.840,
3045.81006,1020.598,4124.38184,1558.840,
3045.90161,1020.598,4124.47363,1558.840,
3045.99316,1020.598,4124.56494,1558.840,
3046.08447,1021.598,4124.65625,1558.840,
3046.17603,1020.598,4124.74805,1559.840,
3046.26758,1021.598,4124.83936,1559.840,
3046.35913,1021.598,4124.93115,1560.840,
3046.45068,1021.598,4125.02246,1560.840,
3046.54224,1021.598,4125.11426,1560.840,
3046.63379,1021.598,4125.20557,1561.840,
3046.72534,1022.598,4125.29688,1561.840,
3046.81665,1022.598,4125.38867,1561.840,
3046.90820,1023.598,4125.47998,1561.840,
3046.99976,1022.598,4125.57178,1562.840,
3047.09131,1023.598,4125.66309,1562.840,
3047.18286,1023.598,4125.75488,1561.840,
3047.27441,1023.598,4125.84619,1562.840,
3047.36597,1023.598,4125.93750,1563.840,
3047.45752,1023.598,4126.02930,1562.840,
3047.54883,1024.598,4126.12061,1563.840,
3047.64038,1023.598,4126.21240,1564.840,
3047.73193,1024.598,4126.30371,1564.840,
3047.82349,1024.598,4126.39551,1564.840,
3047.91504,1024.598,4126.48682,1564.840,
3048.00659,1024.598,4126.57861,1565.840,
3048.09814,1025.598,4126.66992,1565.840,
3048.18945,1025.598,4126.76123,1565.840,
3048.28101,1025.598,4126.85303,1565.840,
3048.37256,1025.598,4126.94434,1565.840,
3048.46411,1026.598,4127.03613,1566.840,
3048.55566,1026.598,4127.12744,1566.840,
3048.64722,1026.598,4127.21924,1567.840,
3048.73877,1026.598,4127.31055,1567.840,
3048.83032,1026.598,4127.40186,1568.840,
3048.92163,1027.598,4127.49365,1568.840,
3049.01318,1026.598,4127.58496,1567.840,
3049.10474,1027.598,4127.67676,1568.840,
3049.19629,1027.598,4127.76807,1569.840,
3049.28784,1027.598,4127.85986,1568.840,
3049.37939,1027.598,4127.95117,1569.840,
3049.47095,1027.598,4128.04248,1569.840,
3049.56250,1028.598,4128.13428,1569.840,
3049.65381,1029.598,4128.22559,1570.840,
3049.74536,1029.598,4128.31738,1570.840,
3049.83691,1029.598,4128.40869,1570.840,
3049.92847,1029.598,4128.50049,1570.840,
3050.02002,1029.598,4128.59180,1571.840,
3050.11157,1029.598,4128.68359,1571.840,
3050.20313,1030.598,4128.77490,1571.840,
3050.29443,1030.598,4128.86621,1572.840,
3050.38599,1030.598,4128.95801,1572.840,
3050.47754,1030.598,4129.04932,1572.840,
3050.56909,1031.598,4129.14111,1572.840,
3050.66064,1031.598,4129.23242,1574.840,
3050.75220,1030.598,4129.32422,1574.840,
3050.84375,1031.598,4129.41553,1573.840,
3050.93530,1031.598,4129.50684,1574.840,
3051.02661,1031.598,4129.59863,1574.840,
3051.11816,1032.598,4129.68994,1574.840,
3051.20972,1032.598,4129.78174,1575.840,
3051.30127,1032.598,4129.87305,1576.840,
3051.39282,1032.598,4129.96484,1575.840,
3051.48438,1033.598,4130.05615,1576.840,
3051.57593,1033.598,4130.14746,1576.840,
3051.66748,1033.598,4130.23926,1576.840,
3051.75879,1033.598,4130.33057,1577.840,
3051.85034,1033.598,4130.42236,1577.840,
3051.94189,1033.598,4130.51367,1577.840,
3052.03345,1033.598,4130.60547,1577.840,
3052.12500,1033.598,4130.69678,1578.840,
3052.21655,1033.598,4130.78857,1578.840,
3052.30811,1034.598,4130.87988,1579.840,
3052.39941,1034.598,4130.97119,1578.840,
3052.49097,1034.598,4131.06299,1579.840,
3052.58252,1035.598,4131.15430,1579.840,
3052.67407,1035.598,4131.24609,1580.840,
3052.76563,1035.598,4131.33740,1580.840,
3052.85718,1035.598,4131.42920,1580.840,
3052.94873,1035.598,4131.52051,1580.840,
3053.04028,1036.598,4131.61182,1581.840,
3053.13159,1036.598,4131.70361,1581.840,
3053.22314,1036.598,4131.79492,1581.840,
3053.31470,1036.598,4131.88672,1582.840,
3053.40625,1036.598,4131.97803,1582.840,
3053.49780,1037.598,4132.06982,1582.840,
3053.58936,1037.598,4132.16113,1582.840,
3053.68091,1037.598,4132.25244,1583.840,
3053.77222,1037.598,4132.34424,1583.840,
3053.86377,1038.598,4132.43555,1583.840,
3053.95532,1038.598,4132.52734,1584.840,
3054.04688,1038.598,4132.61865,1584.840,
3054.13843,1038.598,4132.71045,1584.840,
3054.22998,1039.598,4132.80176,1585.840,
3054.32153,1038.598,4132.89355,1584.840,
3054.41309,1039.598,4132.98486,1585.840,
3054.50439,1039.598,4133.07617,1585.840,
3054.59595,1039.598,4133.16797,1585.840,
3054.68750,1040.598,4133.25928,1586.840,
3054.77905,1041.598,4133.35107,1586.840,
3054.87061,1041.598,4133.44238,1586.840,
3054.96216,1042.598,4133.53418,1586.840,
3055.05371,1043.598,4133.62549,1586.840,
3055.14526,1044.598,4133.71680,1587.840,
3055.23657,1044.598,4133.80859,1587.840,
3055.32813,1044.598,4133.89990,1587.840,
3055.41968,1045.598,4133.99170,1588.840,
3055.51123,1045.598,4134.08301,1588.840,
3055.60278,1044.598,4134.17480,1588.840,
3055.69434,1045.598,4134.26611,1589.840,
3055.78589,1045.598,4134.35742,1589.840,
3055.87720,1044.598,4134.44922,1589.840,
3055.96875,1045.598,4134.54053,1589.840,
3056.06030,1044.598,4134.63232,1590.840,
3056.15186,1044.598,4134.72363,1591.840,
3056.24341,1044.598,4134.81543,1590.840,
3056.33496,1044.598,4134.90674,1591.840,
3056.42651,1045.598,4134.99805,1592.840,
3056.51807,1044.598,4135.08984,1591.840,
3056.60938,1045.598,4135.18115,1592.840,
3056.70093,1044.598,4135.27295,1592.840,
3056.79248,1044.598,4135.36426,1592.840,
3056.88403,1044.598,4135.45605,1593.840,
3056.97559,1045.598,4135.54736,1593.840,
3057.06714,1044.598,4135.63916,1593.840,
3057.15869,1043.598,4135.73047,1593.840,
3057.25024,1044.598,4135.82178,1594.840,
3057.34155,1043.598,4135.91357,1594.840,
3057.43311,1043.598,4136.00488,1594.840,
3057.52466,1043.598,4136.09668,1595.840,
3057.61621,1043.598,4136.18799,1596.840,
3057.70776,1043.598,4136.27979,1595.840,
3057.79932,1043.598,4136.37109,1595.840,
3057.89087,1044.598,4136.46240,1596.840,
3057.98218,1044.598,4136.55420,1596.840,
3058.07373,1043.598,4136.64551,1596.840,
3058.16528,1044.598,4136.73730,1597.840,
3058.25684,1045.598,4136.82861,1597.840,
3058.34839,1045.598,4136.92041,1598.840,
3058.43994,1046.598,4137.01172,1598.840,
3058.53149,1046.598,4137.10303,1598.840,
3058.62305,1047.598,4137.19482,1598.840,
3058.71436,1047.598,4137.28613,1599.840,
3058.80591,1047.598,4137.37793,1599.840,
3058.89746,1047.598,4137.46924,1599.840,
3058.98901,1048.598,4137.56104,1600.840,
3059.08057,1049.598,4137.65234,1601.840,
3059.17212,1048.598,4137.74414,1600.840,
3059.26367,1049.598,4137.83545,1600.840,
3059.35498,1050.598,4137.92676,1600.840,
3059.44653,1049.598,4138.01855,1601.840,
3059.53809,1050.598,4138.10986,1601.840,
3059.62964,1050.598,4138.20166,1601.840,
3059.72119,1050.598,4138.29297,1602.840,
3059.81274,1050.598,4138.38477,1601.840,
3059.90430,1051.598,4138.47607,1602.840,
3059.99585,1051.598,4138.56738,1603.840,
3060.08716,1051.598,4138.65918,1603.840,
3060.17871,1051.598,4138.75049,1603.840,
3060.27026,1052.598,4138.84229,1603.840,
3060.36182,1051.598,4138.93359,1604.840,
3060.45337,1052.598,4139.02539,1604.840,
3060.54492,1052.598,4139.11670,1605.840,
3060.63647,1052.598,4139.20801,1605.840,
3060.72803,1052.598,4139.29980,1605.840,
3060.81934,1053.598,4139.39111,1606.840,
3060.91089,1053.598,4139.48291,1606.840,
3061.00244,1053.598,4139.57422,1606.840,
3061.09399,1053.598,4139.66602,1606.840,
3061.18555,1054.598,4139.75732,1607.840,
3061.27710,1054.598,4139.84912,1608.840,
3061.36865,1054.598,4139.94043,1607.840,
3061.45996,1054.598,4140.03174,1608.840,
3061.55151,1054.598,4140.12354,1608.840,
3061.64307,1055.598,4140.21484,1608.840,
3061.73462,1055.598,4140.30664,1609.840,
3061.82617,1055.598,4140.39795,1609.840,
3061.91772,1055.598,4140.48975,1609.840,
3062.00928,1055.598,4140.58105,1609.840,
3062.10083,1055.598,4140.67236,1610.840,
3062.19214,1056.598,4140.76416,1611.840,
3062.28369,1056.598,4140.85547,1610.840,
3062.37524,1057.598,4140.94727,1610.840,
3062.46680,1056.598,4141.03857,1610.840,
3062.55835,1056.598,4141.13037,1611.840,
3062.64990,1057.598,4141.22168,1612.840,
3062.74146,1057.598,4141.31299,1612.840,
3062.83301,1058.598,4141.40479,1612.840,
3062.92432,1058.598,4141.49609,1612.840,
3063.01587,1058.598,4141.58789,1613.840,
3063.10742,1058.598,4141.67920,1613.840,
3063.19897,1059.598,4141.77100,1613.840,
3063.29053,1058.598,4141.86230,1613.840,
3063.38208,1059.598,4141.95410,1613.840,
3063.47363,1059.598,4142.04541,1614.840,
3063.56494,1059.598,4142.13672,1613.840,
3063.65649,1059.598,4142.22852,1613.840,
3063.74805,1059.598,4142.31982,1613.840,
3063.83960,1059.598,4142.41162,1614.840,
3063.93115,1059.598,4142.50293,1615.840,
3064.02271,1060.598,4142.59473,1614.840,
3064.11426,1060.598,4142.68604,1615.840,
3064.20581,1060.598,4142.77734,1616.840,
3064.29712,1061.598,4142.86914,1616.840,
3064.38867,1061.598,4142.96045,1616.840,
3064.48022,1061.598,4143.05225,1617.840,
3064.57178,1061.598,4143.14355,1617.840,
3064.66333,1062.598,4143.23535,1617.840,
3064.75488,1062.598,4143.32666,1617.840,
3064.84644,1062.598,4143.41797,1618.840,
3064.93774,1062.598,4143.50977,1619.840,
3065.02930,1062.598,4143.60107,1619.840,
3065.12085,1063.598,4143.69287,1619.840,
3065.21240,1062.598,4143.78418,1619.840,
3065.30396,1062.598,4143.87598,1619.840,
3065.39551,1063.598,4143.96729,1620.840,
3065.48706,1063.598,4144.05908,1620.840,
3065.57861,1063.598,4144.15039,1620.840,
3065.66992,1063.598,4144.24170,1621.840,
3065.76147,1064.598,4144.33350,1621.840,
3065.85303,1064.598,4144.42480,1621.840,
3065.94458,1065.598,4144.51660,1621.840,
3066.03613,1064.598,4144.60791,1622.840,
3066.12769,1064.598,4144.69971,1622.840,
3066.21924,1065.598,4144.79102,1622.840,
3066.31079,1065.598,4144.88232,1623.840,
3066.40210,1065.598,4144.97412,1623.840,
3066.49365,1065.598,4145.06543,1623.840,
3066.58521,1065.598,4145.15723,1623.840,
3066.67676,1066.598,4145.24854,1623.840,
3066.76831,1066.598,4145.34033,1623.840,
3066.85986,1066.598,4145.43164,1625.840,
3066.95142,1067.598,4145.52295,1624.840,
3067.04272,1067.598,4145.61475,1624.840,
3067.13428,1067.598,4145.70605,1625.840,
3067.22583,1067.598,4145.79785,1625.840,
3067.31738,1067.598,4145.88916,1625.840,
3067.40894,1067.598,4145.98096,1626.840,
3067.50049,1068.598,4146.07227,1626.840,
3067.59204,1068.598,4146.16357,1626.840,
3067.68359,1068.598,4146.25537,1627.840,
3067.77490,1068.598,4146.34668,1627.840,
3067.86646,1069.598,4146.43848,1628.840,
3067.95801,1069.598,4146.52979,1628.840,
3068.04956,1069.598,4146.62158,1628.840,
3068.14111,1070.598,4146.71289,1628.840,
3068.23267,1070.598,4146.80469,1629.840,
3068.32422,1070.598,4146.89600,1629.840,
3068.41577,1070.598,4146.98730,1629.840,
3068.50708,1070.598,4147.07910,1630.840,
3068.59863,1070.598,4147.17041,1629.840,
3068.69019,1071.598,4147.26221,1630.840,
3068.78174,1071.598,4147.35352,1630.840,
3068.87329,1071.598,4147.44531,1631.840,
3068.96484,1071.598,4147.53662,1630.840,
3069.05640,1071.598,4147.62793,1631.840,
3069.14771,1071.598,4147.71973,1631.840,
3069.23926,1072.598,4147.81104,1632.840,
3069.33081,1073.598,4147.90283,1632.840,
3069.42236,1073.598,4147.99414,1632.840,
3069.51392,1072.598,4148.08594,1633.840,
3069.60547,1073.598,4148.17725,1633.840,
3069.69702,1073.598,4148.26855,1634.840,
3069.78857,1073.598,4148.36035,1633.840,
3069.87988,1073.598,4148.45166,1633.840,
3069.97144,1074.598,4148.54346,1634.840,
3070.06299,1074.598,4148.63477,1634.840,
3070.15454,1074.598,4148.72656,1634.840,
3070.24609,1074.598,4148.81787,1635.840,
3070.33765,1074.598,4148.90967,1635.840,
3070.42920,1074.598,4149.00098,1635.840,
3070.52075,1075.598,4149.09229,1636.840,
3070.61206,1075.598,4149.18408,1636.840,
3070.70361,1075.598,4149.27539,1636.840,
3070.79517,1075.598,4149.36719,1637.840,
3070.88672,1075.598,4149.45850,1637.840,
3070.97827,1075.598,4149.55029,1637.840,
3071.06982,1076.598,4149.64160,1638.840,
3071.16138,1076.598,4149.73291,1638.840,
3071.25269,1076.598,4149.82471,1637.840,
3071.34424,1076.598,4149.91602,1638.840,
3071.43579,1077.598,4150.00781,1638.840,
3071.52734,1077.598,4150.09912,1639.840,
3071.61890,1077.598,4150.19092,1639.840,
3071.71045,1077.598,4150.28223,1639.840,
3071.80200,1078.598,4150.37354,1639.840,
3071.89355,1077.598,4150.46533,1640.840,
3071.98486,1078.598,4150.55664,1640.840,
3072.07642,1079.598,4150.64844,1640.840,
3072.16797,1078.598,4150.73975,1641.840,
3072.25952,1079.598,4150.83154,1642.840,
3072.35107,1079.598,4150.92285,1641.840,
3072.44263,1080.598,4151.01465,1642.840,
3072.53418,1079.598,4151.10596,1642.840,
3072.62549,1080.598,4151.19727,1642.840,
3072.71704,1080.598,4151.28906,1643.840,
3072.80859,1080.598,4151.38037,1643.840,
3072.90015,1081.598,4151.47217,1643.840,
3072.99170,1081.598,4151.56348,1643.840,
3073.08325,1082.598,4151.65527,1643.840,
3073.17480,1082.598,4151.74658,1644.840,
3073.26636,1082.598,4151.83789,1644.840,
3073.35767,1082.598,4151.92969,1644.840,
3073.44922,1082.598,4152.02100,1644.840,
3073.54077,1083.598,4152.11279,1645.840,
3073.63232,1083.598,4152.20410,1645.840,
3073.72388,1082.598,4152.29590,1646.840,
3073.81543,1082.598,4152.38721,1646.840,
3073.90698,1083.598,4152.47852,1646.840,
3073.99854,1083.598,4152.57031,1646.840,
3074.08984,1083.598,4152.66162,1647.840,
3074.18140,1083.598,4152.75342,1647.840,
3074.27295,1083.598,4152.84473,1647.840,
3074.36450,1084.598,4152.93652,1648.840,
3074.45605,1084.598,4153.02783,1648.840,
3074.54761,1084.598,4153.11963,1648.840,
3074.63916,1084.598,4153.21094,1649.840,
3074.73047,1084.598,4153.30225,1649.840,
3074.82202,1085.598,4153.39404,1649.840,
3074.91357,1085.598,4153.48535,1649.840,
3075.00513,1085.598,4153.57715,1650.840,
3075.09668,1086.598,4153.66846,1650.840,
3075.18823,1086.598,4153.76025,1651.840,
3075.27979,1086.598,4153.85156,1651.840,
3075.37134,1086.598,4153.94287,1651.840,
3075.46265,1087.598,4154.03467,1651.840,
3075.55420,1087.598,4154.12598,1652.840,
3075.64575,1088.598,4154.21777,1652.840,
3075.73730,1088.598,4154.30908,1652.840,
3075.82886,1087.598,4154.40088,1653.840,
3075.92041,1088.598,4154.49219,1653.840,
3076.01196,1089.598,4154.58350,1653.840,
3076.10352,1088.598,4154.67529,1653.840,
3076.19482,1089.598,4154.76660,1654.840,
3076.28638,1089.598,4154.85840,1654.840,
3076.37793,1089.598,4154.94971,1655.840,
3076.46948,1089.598,4155.04150,1655.840,
3076.56104,1089.598,4155.13281,1655.840,
3076.65259,1089.598,4155.22461,1656.840,
3076.74414,1089.598,4155.31592,1655.840,
3076.83545,1089.598,4155.40723,1656.840,
3076.92700,1090.598,4155.49902,1656.840,
3077.01855,1090.598,4155.59033,1657.840,
3077.11011,1090.598,4155.68213,1657.840,
3077.20166,1091.598,4155.77344,1657.840,
3077.29321,1090.598,4155.86523,1657.840,
3077.38477,1090.598,4155.95654,1657.840,
3077.47632,1091.598,4156.04785,1658.840,
3077.56763,1091.598,4156.13965,1658.840,
3077.65918,1091.598,4156.23096,1658.840,
3077.75073,1091.598,4156.32275,1659.840,
3077.84229,1092.598,4156.41406,1659.840,
3077.93384,1091.598,4156.50586,1659.840,
3078.02539,1091.598,4156.59717,1660.840,
3078.11694,1092.598,4156.68848,1661.840,
3078.20825,1092.598,4156.78027,1660.840,
3078.29980,1092.598,4156.87158,1661.840,
3078.39136,1092.598,4156.96338,1661.840,
3078.48291,1093.598,4157.05469,1661.840,
3078.57446,1093.598,4157.14648,1661.840,
3078.66602,1094.598,4157.23779,1662.840,
3078.75757,1094.598,4157.32959,1662.840,
3078.84912,1094.598,4157.42090,1662.840,
3078.94043,1095.598,4157.51221,1663.840,
3079.03198,1094.598,4157.60400,1663.840,
3079.12354,1095.598,4157.69531,1663.840,
3079.21509,1095.598,4157.78711,1664.840,
3079.30664,1095.598,4157.87842,1663.840,
3079.39819,1096.598,4157.97021,1664.840,
3079.48975,1096.598,4158.06152,1664.840,
3079.58130,1096.598,4158.15283,1666.840,
3079.67261,1096.598,4158.24463,1665.840,
3079.76416,1096.598,4158.33594,1665.840,
3079.85571,1096.598,4158.42773,1666.840,
3079.94727,1096.598,4158.51904,1666.840,
3080.03882,1097.598,4158.61084,1666.840,
3080.13037,1097.598,4158.70215,1666.840,
3080.22192,1097.598,4158.79346,1667.840,
3080.31323,1097.598,4158.88525,1667.840,
3080.40479,1098.598,4158.97656,1667.840,
3080.49634,1097.598,4159.06836,1668.840,
3080.58789,1098.598,4159.15967,1667.840,
3080.67944,1098.598,4159.25146,1668.840,
3080.77100,1099.598,4159.34277,1668.840,
3080.86255,1099.598,4159.43408,1668.840,
3080.95410,1099.598,4159.52588,1668.840,
3081.04541,1100.598,4159.61719,1670.840,
3081.13696,1100.598,4159.70898,1670.840,
3081.22852,1100.598,4159.80029,1670.840,
3081.32007,1100.598,4159.89209,1670.840,
3081.41162,1100.598,4159.98340,1671.840,
3081.50317,1100.598,4160.07520,1670.840,
3081.59473,1100.598,4160.16650,1672.840,
3081.68628,1101.598,4160.25781,1672.840,
3081.77759,1101.598,4160.34961,1672.840,
3081.86914,1102.598,4160.44092,1672.840,
3081.96069,1101.598,4160.53271,1673.840,
3082.05225,1102.598,4160.62402,1673.840,
3082.14380,1102.598,4160.71582,1673.840,
3082.23535,1102.598,4160.80713,1674.840,
3082.32690,1102.598,4160.89844,1673.840,
3082.41821,1102.598,4160.99023,1674.840,
3082.50977,1102.598,4161.08154,1675.840,
3082.60132,1103.598,4161.17334,1675.840,
3082.69287,1103.598,4161.26465,1674.840,
3082.78442,1103.598,4161.35645,1675.840,
3082.87598,1103.598,4161.44775,1675.840,
3082.96753,1104.598,4161.53906,1675.840,
3083.05908,1104.598,4161.63086,1675.840,
3083.15039,1103.598,4161.72217,1676.840,
3083.24194,1104.598,4161.81396,1676.840,
3083.33350,1105.598,4161.90527,1676.840,
3083.42505,1104.598,4161.99707,1677.840,
3083.51660,1105.598,4162.08838,1677.840,
3083.60815,1105.598,4162.18018,1677.840,
3083.69971,1105.598,4162.27148,1678.840,
3083.79102,1106.598,4162.36279,1678.840,
3083.88257,1105.598,4162.45459,1679.840,
3083.97412,1106.598,4162.54590,1679.840,
3084.06567,1106.598,4162.63770,1679.840,
3084.15723,1107.598,4162.72900,1680.840,
3084.24878,1106.598,4162.82080,1680.840,
3084.34033,1107.598,4162.91211,1680.840,
3084.43188,1107.598,4163.00342,1681.840,
3084.52319,1108.598,4163.09521,1681.840,
3084.61475,1108.598,4163.18652,1682.840,
3084.70630,1108.598,4163.27832,1682.840,
3084.79785,1109.598,4163.36963,1681.840,
3084.88940,1108.598,4163.46143,1682.840,
3084.98096,1108.598,4163.55273,1682.840,
3085.07251,1109.598,4163.64404,1683.840,
3085.16406,1109.598,4163.73584,1683.840,
3085.25537,1109.598,4163.82715,1683.840,
3085.34692,1109.598,4163.91895,1684.840,
3085.43848,1110.598,4164.01025,1684.840,
3085.53003,1110.598,4164.10205,1684.840,
3085.62158,1110.598,4164.19336,1684.840,
3085.71313,1110.598,4164.28516,1684.840,
3085.80469,1110.598,4164.37646,1685.840,
3085.89600,1110.598,4164.46777,1685.840,
3085.98755,1111.598,4164.55957,1685.840,
3086.07910,1111.598,4164.65088,1686.840,
3086.17065,1111.598,4164.74268,1686.840,
3086.26221,1112.598,4164.83398,1686.840,
3086.35376,1111.598,4164.92578,1687.840,
3086.44531,1112.598,4165.01709,1687.840,
3086.53687,1112.598,4165.10840,1687.840,
3086.62817,1112.598,4165.20020,1687.840,
3086.71973,1112.598,4165.29150,1688.840,
3086.81128,1113.598,4165.38330,1688.840,
3086.90283,1113.598,4165.47461,1689.840,
3086.99438,1113.598,4165.56641,1689.840,
3087.08594,1114.598,4165.65771,1689.840,
3087.17749,1114.598,4165.74902,1689.840,
3087.26904,1114.598,4165.84082,1689.840,
3087.36035,1114.598,4165.93213,1690.840,
3087.45190,1114.598,4166.02393,1690.840,
3087.54346,1114.598,4166.11523,1691.840,
3087.63501,1115.598,4166.20703,1691.840,
3087.72656,1115.598,4166.29834,1691.840,
3087.81812,1115.598,4166.39014,1691.840,
3087.90967,1115.598,4166.48145,1691.840,
3088.00098,1115.598,4166.57275,1692.840,
3088.09253,1116.598,4166.66455,1692.840,
3088.18408,1116.598,4166.75586,1692.840,
3088.27563,1116.598,4166.84766,1693.840,
3088.36719,1116.598,4166.93896,1693.840,
3088.45874,1117.598,4167.03076,1693.840,
3088.55029,1117.598,4167.12207,1694.840,
3088.64185,1117.598,4167.21338,1694.840,
3088.73315,1117.598,4167.30518,1694.840,
3088.82471,1117.598,4167.39648,1695.840,
3088.91626,1117.598,4167.48828,1695.840,
3089.00781,1118.598,4167.57959,1695.840,
3089.09937,1118.598,4167.67139,1695.840,
3089.19092,1118.598,4167.76270,1696.840,
3089.28247,1119.598,4167.85400,1696.840,
3089.37378,1118.598,4167.94580,1696.840,
3089.46533,1118.598,4168.03711,1697.840,
3089.55688,1119.598,4168.12891,1697.840,
3089.64844,1119.598,4168.22021,1697.840,
3089.73999,1119.598,4168.31201,1697.840,
3089.83154,1120.598,4168.40332,1699.840,
3089.92310,1120.598,4168.49512,1699.840,
3090.01465,1121.598,4168.58643,1698.840,
3090.10596,1121.598,4168.67773,1699.840,
3090.19751,1121.598,4168.76953,1699.840,
3090.28906,1122.598,4168.86084,1699.840,
3090.38062,1123.598,4168.95264,1700.840,
3090.47217,1123.598,4169.04395,1700.840,
3090.56372,1124.598,4169.13574,1700.840,
3090.65527,1125.598,4169.22705,1701.840,
3090.74683,1124.598,4169.31836,1701.840,
3090.83813,1125.598,4169.41016,1701.840,
3090.92969,1125.598,4169.50146,1701.840,
3091.02124,1125.598,4169.59326,1702.840,
3091.11279,1125.598,4169.68457,1702.840,
3091.20435,1125.598,4169.77637,1702.840,
3091.29590,1125.598,4169.86768,1703.840,
3091.38745,1125.598,4169.95898,1703.840,
3091.47876,1125.598,4170.05078,1703.840,
3091.57031,1125.598,4170.14209,1703.840,
3091.66187,1125.598,4170.23389,1704.840,
3091.75342,1126.598,4170.32520,1704.840,
3091.84497,1125.598,4170.41699,1705.840,
3091.93652,1125.598,4170.50830,1705.840,
3092.02808,1126.598,4170.60010,1705.840,
3092.11963,1126.598,4170.69141,1705.840,
3092.21094,1126.598,4170.78271,1705.840,
3092.30249,1126.598,4170.87451,1705.840,
3092.39404,1126.598,4170.96582,1706.840,
3092.48560,1126.598,4171.05762,1706.840,
3092.57715,1127.598,4171.14893,1707.840,
3092.66870,1126.598,4171.24072,1707.840,
3092.76025,1127.598,4171.33203,1708.840,
3092.85181,1128.598,4171.42334,1708.840,
3092.94312,1128.598,4171.51514,1708.840,
3093.03467,1128.598,4171.60645,1708.840,
3093.12622,1129.598,4171.69824,1709.840,
3093.21777,1130.598,4171.78955,1709.840,
3093.30933,1130.598,4171.88135,1709.840,
3093.40088,1130.598,4171.97266,1710.840,
3093.49243,1131.598,4172.06396,1710.840,
3093.58374,1131.598,4172.15576,1710.840,
3093.67529,1131.598,4172.24707,1710.840,
3093.76685,1131.598,4172.33887,1710.840,
3093.85840,1131.598,4172.43018,1711.840,
3093.94995,1131.598,4172.52197,1711.840,
3094.04150,1131.598,4172.61328,1711.840,
3094.13306,1132.598,4172.70459,1712.840,
3094.22461,1132.598,4172.79639,1713.840,
3094.31592,1131.598,4172.88770,1713.840,
3094.40747,1132.598,4172.97949,1713.840,
3094.49902,1132.598,4173.07080,1713.840,
3094.59058,1132.598,4173.16260,1714.840,
3094.68213,1132.598,4173.25391,1714.840,
3094.77368,1132.598,4173.34570,1713.840,
3094.86523,1132.598,4173.43701,1714.840,
3094.95679,1132.598,4173.52832,1715.840,
3095.04810,1133.598,4173.62012,1715.840,
3095.13965,1133.598,4173.71143,1716.840,
3095.23120,1133.598,4173.80322,1716.840,
3095.32275,1133.598,4173.89453,1716.840,
3095.41431,1134.598,4173.98633,1716.840,
3095.50586,1134.598,4174.07764,1716.840,
3095.59741,1135.598,4174.16895,1717.840,
3095.68872,1135.598,4174.26074,1718.840,
3095.78027,1134.598,4174.35205,1718.840,
3095.87183,1134.598,4174.44385,1718.840,
3095.96338,1135.598,4174.53516,1718.840,
3096.05493,1135.598,4174.62695,1718.840,
3096.14648,1135.598,4174.71826,1718.840,
3096.23804,1135.598,4174.80957,1719.840,
3096.32959,1136.598,4174.90137,1719.840,
3096.42090,1136.598,4174.99268,1719.840,
3096.51245,1136.598,4175.08447,1719.840,
3096.60400,1136.598,4175.17578,1720.840,
3096.69556,1136.598,4175.26758,1720.840,
3096.78711,1137.598,4175.35889,1720.840,
3096.87866,1137.598,4175.45068,1721.840,
3096.97021,1137.598,4175.54199,1721.840,
3097.06152,1137.598,4175.63330,1722.840,
3097.15308,1137.598,4175.72510,1722.840,
3097.24463,1137.598,4175.81641,1723.840,
3097.33618,1138.598,4175.90820,1723.840,
3097.42773,1138.598,4175.99951,1723.840,
3097.51929,1138.598,4176.09131,1723.840,
3097.61084,1138.598,4176.18262,1724.840,
3097.70239,1139.598,4176.27393,1724.840,
3097.79370,1139.598,4176.36572,1724.840,
3097.88525,1139.598,4176.45703,1725.840,
3097.97681,1140.598,4176.54883,1725.840,
3098.06836,1140.598,4176.64014,1725.840,
3098.15991,1140.598,4176.73193,1725.840,
3098.25146,1140.598,4176.82324,1726.840,
3098.34302,1141.598,4176.91455,1726.840,
3098.43457,1141.598,4177.00635,1727.840,
3098.52588,1141.598,4177.09766,1726.840,
3098.61743,1141.598,4177.18945,1727.840,
3098.70898,1141.598,4177.28076,1727.840,
3098.80054,1141.598,4177.37256,1728.840,
3098.89209,1142.598,4177.46387,1727.840,
3098.98364,1142.598,4177.55566,1727.840,
3099.07520,1142.598,4177.64697,1728.840,
3099.16650,1142.598,4177.73828,1729.840,
3099.25806,1143.598,4177.83008,1729.840,
3099.34961,1143.598,4177.92139,1729.840,
3099.44116,1143.598,4178.01318,1729.840,
3099.53271,1143.598,4178.10449,1730.840,
3099.62427,1144.598,4178.19629,1730.840,
3099.71582,1144.598,4178.28760,1731.840,
3099.80737,1144.598,4178.37891,1731.840,
3099.89868,1144.598,4178.47070,1732.840,
3099.99023,1144.598,4178.56201,1732.840,
3100.08179,1145.598,4178.65381,1733.840,
3100.17334,1146.598,4178.74512,1733.840,
3100.26489,1145.598,4178.83691,1734.840,
3100.35645,1145.598,4178.92822,1734.840,
3100.44800,1146.598,4179.01953,1734.840,
3100.53955,1146.598,4179.11133,1735.840,
3100.63086,1146.598,4179.20264,1735.840,
3100.72241,1146.598,4179.29443,1735.840,
3100.81396,1146.598,4179.38574,1734.840,
3100.90552,1147.598,4179.47754,1735.840,
3100.99707,1146.598,4179.56885,1735.840,
3101.08862,1147.598,4179.66064,1736.840,
3101.18018,1147.598,4179.75195,1736.840,
3101.27148,1147.598,4179.84326,1736.840,
3101.36304,1147.598,4179.93506,1736.840,
3101.45459,1148.598,4180.02637,1736.840,
3101.54614,1148.598,4180.11816,1737.840,
3101.63770,1147.598,4180.20947,1736.840,
3101.72925,1148.598,4180.30127,1736.840,
3101.82080,1148.598,4180.39258,1737.840,
3101.91235,1149.598,4180.48389,1737.840,
3102.00366,1149.598,4180.57568,1737.840,
3102.09521,1149.598,4180.66699,1738.840,
3102.18677,1149.598,4180.75879,1738.840,
3102.27832,1150.598,4180.85010,1739.840,
3102.36987,1151.598,4180.94189,1739.840,
3102.46143,1150.598,4181.03320,1739.840,
3102.55298,1151.598,4181.12451,1739.840,
3102.64429,1151.598,4181.21631,1739.840,
3102.73584,1151.598,4181.30762,1740.840,
3102.82739,1151.598,4181.39941,1740.840,
3102.91895,1152.598,4181.49072,1740.840,
3103.01050,1152.598,4181.58252,1741.840,
3103.10205,1152.598,4181.67383,1741.840,
3103.19360,1152.598,4181.76563,1742.840,
3103.28516,1152.598,4181.85693,1742.840,
3103.37646,1152.598,4181.94824,1742.840,
3103.46802,1152.598,4182.04004,1742.840,
3103.55957,1153.598,4182.13135,1743.840,
3103.65112,1153.598,4182.22314,1743.840,
3103.74268,1153.598,4182.31445,1743.840,
3103.83423,1154.598,4182.40625,1744.840,
3103.92578,1154.598,4182.49756,1744.840,
3104.01733,1154.598,4182.58887,1744.840,
3104.10864,1154.598,4182.68066,1744.840,
3104.20020,1154.598,4182.77197,1745.840,
3104.29175,1154.598,4182.86377,1745.840,
3104.38330,1155.598,4182.95508,1745.840,
3104.47485,1156.598,4183.04688,1746.840,
3104.56641,1155.598,4183.13818,1746.840,
3104.65796,1155.598,4183.22949,1746.840,
3104.74927,1156.598,4183.32129,1747.840,
3104.84082,1156.598,4183.41260,1747.840,
3104.93237,1156.598,4183.50439,1747.840,
3105.02393,1157.598,4183.59570,1748.840,
3105.11548,1157.598,4183.68750,1749.840,
3105.20703,1157.598,4183.77881,1748.840,
3105.29858,1158.598,4183.87012,1748.840,
3105.39014,1157.598,4183.96191,1749.840,
3105.48145,1157.598,4184.05322,1749.840,
3105.57300,1158.598,4184.14502,1749.840,
3105.66455,1158.598,4184.23633,1749.840,
3105.75610,1158.598,4184.32813,1750.840,
3105.84766,1159.598,4184.41943,1750.840,
3105.93921,1159.598,4184.51123,1751.840,
3106.03076,1159.598,4184.60254,1751.840,
3106.12231,1159.598,4184.69385,1751.840,
3106.21362,1160.598,4184.78564,1751.840,
3106.30518,1159.598,4184.87695,1752.840,
3106.39673,1159.598,4184.96875,1751.840,
3106.48828,1160.598,4185.06006,1752.840,
3106.57983,1161.598,4185.15186,1753.840,
3106.67139,1160.598,4185.24316,1752.840,
3106.76294,1161.598,4185.33447,1753.840,
3106.85425,1161.598,4185.42627,1753.840,
3106.94580,1162.598,4185.51758,1753.840,
3107.03735,1161.598,4185.60938,1754.840,
3107.12891,1162.598,4185.70068,1754.840,
3107.22046,1162.598,4185.79248,1755.840,
3107.31201,1162.598,4185.88379,1755.840,
3107.40356,1163.598,4185.97510,1756.840,
3107.49512,1162.598,4186.06689,1756.840,
3107.58643,1163.598,4186.15820,1755.840,
3107.67798,1163.598,4186.25000,1756.840,
3107.76953,1164.598,4186.34131,1756.840,
3107.86108,1164.598,4186.43311,1757.840,
3107.95264,1163.598,4186.52441,1757.840,
3108.04419,1163.598,4186.61621,1757.840,
3108.13574,1163.598,4186.70752,1758.840,
3108.22705,1163.598,4186.79883,1758.840,
3108.31860,1162.598,4186.89063,1758.840,
3108.41016,1162.598,4186.98193,1758.840,
3108.50171,1162.598,4187.07373,1758.840,
3108.59326,1162.598,4187.16504,1759.840,
3108.68481,1162.598,4187.25684,1759.840,
3108.77637,1163.598,4187.34814,1760.840,
3108.86792,1163.598,4187.43945,1760.840,
3108.95923,1164.598,4187.53125,1760.840,
3109.05078,1165.598,4187.62256,1761.840,
3109.14233,1164.598,4187.71436,1761.840,
3109.23389,1165.598,4187.80566,1761.840,
3109.32544,1166.598,4187.89746,1761.840,
3109.41699,1165.598,4187.98877,1761.840,
3109.50854,1167.598,4188.08008,1762.840,
3109.60010,1167.598,4188.17188,1762.840,
3109.69141,1167.598,4188.26318,1763.840,
3109.78296,1168.598,4188.35498,1763.840,
3109.87451,1168.598,4188.44629,1763.840,
3109.96606,1168.598,4188.53809,1763.840,
3110.05762,1169.598,4188.62939,1763.840,
3110.14917,1169.598,4188.72119,1764.840,
3110.24072,1169.598,4188.81250,1764.840,
3110.33203,1170.598,4188.90381,1765.840,
3110.42358,1171.598,4188.99561,1765.840,
3110.51514,1172.598,4189.08691,1765.840,
3110.60669,1173.598,4189.17871,1765.840,
3110.69824,1173.598,4189.27002,1765.840,
3110.78979,1174.598,4189.36182,1766.840,
3110.88135,1175.598,4189.45313,1766.840,
3110.97290,1175.598,4189.54443,1766.840,
3111.06421,1175.598,4189.63623,1767.840,
3111.15576,1175.598,4189.72754,1768.840,
3111.24731,1175.598,4189.81934,1768.840,
3111.33887,1175.598,4189.91064,1768.840,
3111.43042,1174.598,4190.00244,1768.840,
3111.52197,1175.598,4190.09375,1768.840,
3111.61353,1174.598,4190.18506,1769.840,
3111.70508,1175.598,4190.27686,1769.840,
3111.79639,1174.598,4190.36816,1770.840,
3111.88794,1174.598,4190.45996,1770.840,
3111.97949,1174.598,4190.55127,1770.840,
3112.07104,1174.598,4190.64307,1770.840,
3112.16260,1174.598,4190.73438,1770.840,
3112.25415,1174.598,4190.82617,1771.840,
3112.34570,1175.598,4190.91748,1771.840,
3112.43701,1175.598,4191.00879,1772.840,
3112.52856,1175.598,4191.10059,1772.840,
3112.62012,1176.598,4191.19189,1772.840,
3112.71167,1175.598,4191.28369,1773.840,
3112.80322,1176.598,4191.37500,1773.840,
3112.89478,1176.598,4191.46680,1773.840,
3112.98633,1176.598,4191.55811,1773.840,
3113.07788,1176.598,4191.64941,1774.840,
3113.16919,1176.598,4191.74121,1774.840,
3113.26074,1177.598,4191.83252,1775.840,
3113.35229,1177.598,4191.92432,1774.840,
3113.44385,1177.598,4192.01563,1775.840,
3113.53540,1177.598,4192.10742,1775.840,
3113.62695,1177.598,4192.19873,1775.840,
3113.71851,1177.598,4192.29004,1776.840,
3113.81006,1178.598,4192.38184,1776.840,
3113.90137,1178.598,4192.47314,1776.840,
3113.99292,1178.598,4192.56494,1777.840,
3114.08447,1179.598,4192.65625,1777.840,
3114.17603,1179.598,4192.74805,1777.840,
3114.26758,1179.598,4192.83936,1777.840,
3114.35913,1179.598,4192.93115,1778.840,
3114.45068,1180.598,4193.02246,1778.840,
3114.54199,1180.598,4193.11377,1778.840,
3114.63354,1180.598,4193.20557,1779.840,
3114.72510,1180.598,4193.29688,1780.840,
3114.81665,1181.598,4193.38867,1779.840,
3114.90820,1180.598,4193.47998,1780.840,
3114.99976,1180.598,4193.57178,1780.840,
3115.09131,1181.598,4193.66309,1780.840,
3115.18286,1181.598,4193.75439,1780.840,
3115.27417,1181.598,4193.84619,1781.840,
3115.36572,1182.598,4193.93750,1781.840,
3115.45728,1182.598,4194.02930,1781.840,
3115.54883,1182.598,4194.12061,1782.840,
3115.64038,1183.598,4194.21240,1781.840,
3115.73193,1183.598,4194.30371,1782.840,
3115.82349,1183.598,4194.39502,1782.840,
3115.91479,1183.598,4194.48682,1783.840,
3116.00635,1183.598,4194.57813,1783.840,
3116.09790,1183.598,4194.66992,1783.840,
3116.18945,1184.598,4194.76123,1784.840,
3116.28101,1184.598,4194.85303,1784.840,
3116.37256,1184.598,4194.94434,1784.840,
3116.46411,1184.598,4195.03613,1785.840,
3116.55566,1185.598,4195.12744,1785.840,
3116.64697,1185.598,4195.21875,1785.840,
3116.73853,1185.598,4195.31055,1785.840,
3116.83008,1185.598,4195.40186,1786.840,
3116.92163,1185.598,4195.49365,1786.840,
3117.01318,1186.598,4195.58496,1787.840,
3117.10474,1186.598,4195.67676,1787.840,
3117.19629,1186.598,4195.76807,1787.840,
3117.28784,1186.598,4195.85938,1787.840,
3117.37915,1187.598,4195.95117,1788.840,
3117.47070,1187.598,4196.04248,1788.840,
3117.56226,1187.598,4196.13428,1788.840,
3117.65381,1187.598,4196.22559,1789.840,
3117.74536,1187.598,4196.31738,1789.840,
3117.83691,1187.598,4196.40869,1789.840,
3117.92847,1187.598,4196.50000,1790.840,
3118.01978,1187.598,4196.59180,1790.840,
3118.11133,1188.598,4196.68311,1791.840,
3118.20288,1188.598,4196.77490,1791.840,
3118.29443,1188.598,4196.86621,1791.840,
3118.38599,1189.598,4196.95801,1791.840,
3118.47754,1189.598,4197.04932,1792.840,
3118.56909,1189.598,4197.14063,1792.840,
3118.66064,1190.598,4197.23242,1792.840,
3118.75195,1189.598,4197.32373,1792.840,
3118.84351,1190.598,4197.41553,1792.840,
3118.93506,1190.598,4197.50684,1793.840,
3119.02661,1190.598,4197.59863,1792.840,
3119.11816,1190.598,4197.68994,1793.840,
3119.20972,1191.598,4197.78174,1793.840,
3119.30127,1191.598,4197.87305,1793.840,
3119.39282,1191.598,4197.96436,1793.840,
3119.48413,1191.598,4198.05615,1794.840,
3119.57568,1192.598,4198.14746,1794.840,
3119.66724,1192.598,4198.23926,1795.840,
3119.75879,1192.598,4198.33057,1795.840,
3119.85034,1192.598,4198.42236,1795.840,
3119.94189,1193.598,4198.51367,1796.840,
3120.03345,1193.598,4198.60498,1796.840,
3120.12476,1193.598,4198.69678,1797.840,
3120.21631,1193.598,4198.78809,1797.840,
3120.30786,1193.598,4198.87988,1798.840,
3120.39941,1194.598,4198.97119,1798.840,
3120.49097,1194.598,4199.06299,1798.840,
3120.58252,1194.598,4199.15430,1799.840,
3120.67407,1194.598,4199.24561,1799.840,
3120.76563,1194.598,4199.33740,1800.840,
3120.85693,1194.598,4199.42871,1800.840,
3120.94849,1195.598,4199.52051,1800.840,
3121.04004,1195.598,4199.61182,1801.840,
3121.13159,1195.598,4199.70361,1801.840,
3121.22314,1195.598,4199.79492,1801.840,
3121.31470,1196.598,4199.88672,1801.840,
3121.40625,1197.598,4199.97803,1801.840,
3121.49756,1196.598,4200.06934,1801.840,
3121.58911,1196.598,4200.16113,1802.840,
3121.68066,1197.598,4200.25244,1802.840,
3121.77222,1197.598,4200.34424,1803.840,
3121.86377,1196.598,4200.43555,1803.840,
3121.95532,1197.598,4200.52734,1803.840,
3122.04688,1197.598,4200.61865,1804.840,
3122.13843,1197.598,4200.70996,1804.840,
3122.22974,1198.598,4200.80176,1804.840,
3122.32129,1198.598,4200.89307,1804.840,
3122.41284,1198.598,4200.98486,1804.840,
3122.50439,1198.598,4201.07617,1805.840,
3122.59595,1199.598,4201.16797,1805.840,
3122.68750,1199.598,4201.25928,1805.840,
3122.77905,1199.598,4201.35059,1805.840,
3122.87061,1200.598,4201.44238,1806.840,
3122.96191,1200.598,4201.53369,1806.840,
3123.05347,1199.598,4201.62549,1806.840,
3123.14502,1200.598,4201.71680,1807.840,
3123.23657,1200.598,4201.80859,1807.840,
3123.32813,1200.598,4201.89990,1808.840,
3123.41968,1201.598,4201.99170,1808.840,
3123.51123,1201.598,4202.08301,1809.840,
3123.60254,1201.598,4202.17432,1808.840,
3123.69409,1201.598,4202.26611,1810.840,
3123.78564,1202.598,4202.35742,1809.840,
3123.87720,1202.598,4202.44922,1810.840,
3123.96875,1202.598,4202.54053,1810.840,
3124.06030,1202.598,4202.63232,1810.840,
3124.15186,1202.598,4202.72363,1811.840,
3124.24341,1202.598,4202.81494,1811.840,
3124.33472,1203.598,4202.90674,1811.840,
3124.42627,1203.598,4202.99805,1811.840,
3124.51782,1203.598,4203.08984,1811.840,
3124.60938,1203.598,4203.18115,1812.840,
3124.70093,1204.598,4203.27295,1812.840,
3124.79248,1204.598,4203.36426,1812.840,
3124.88403,1204.598,4203.45557,1813.840,
3124.97559,1205.598,4203.54736,1813.840,
3125.06689,1205.598,4203.63867,1813.840,
3125.15845,1205.598,4203.73047,1814.840,
3125.25000,1205.598,4203.82178,1814.840,
3125.34155,1205.598,4203.91357,1814.840,
3125.43311,1205.598,4204.00488,1815.840,
3125.52466,1205.598,4204.09668,1815.840,
3125.61621,1206.598,4204.18799,1816.840,
3125.70752,1206.598,4204.27930,1816.840,
3125.79907,1207.598,4204.37109,1816.840,
3125.89063,1207.598,4204.46240,1816.840,
3125.98218,1207.598,4204.55420,1817.840,
3126.07373,1207.598,4204.64551,1817.840,
3126.16528,1207.598,4204.73730,1817.840,
3126.25684,1207.598,4204.82861,1817.840,
3126.34839,1207.598,4204.91992,1818.840,
3126.43970,1207.598,4205.01172,1818.840,
3126.53125,1208.598,4205.10303,1818.840,
3126.62280,1207.598,4205.19482,1818.840,
3126.71436,1207.598,4205.28613,1818.840,
3126.80591,1208.598,4205.37793,1819.840,
3126.89746,1208.598,4205.46924,1819.840,
3126.98901,1208.598,4205.56055,1820.840,
3127.08032,1208.598,4205.65234,1820.840,
3127.17188,1209.598,4205.74365,1820.840,
3127.26343,1209.598,4205.83545,1821.840,
3127.35498,1209.598,4205.92676,1821.840,
3127.44653,1210.598,4206.01855,1821.840,
3127.53809,1210.598,4206.10986,1821.840,
3127.62964,1210.598,4206.20166,1822.840,
3127.72119,1210.598,4206.29297,1822.840,
3127.81250,1211.598,4206.38428,1823.840,
3127.90405,1211.598,4206.47607,1824.840,
3127.99561,1211.598,4206.56738,1823.840,
3128.08716,1212.598,4206.65918,1824.840,
3128.17871,1212.598,4206.75049,1824.840,
3128.27026,1212.598,4206.84229,1825.840,
3128.36182,1213.598,4206.93359,1824.840,
3128.45337,1213.598,4207.02490,1824.840,
3128.54468,1213.598,4207.11670,1825.840,
3128.63623,1213.598,4207.20801,1825.840,
3128.72778,1215.598,4207.29980,1825.840,
3128.81934,1214.598,4207.39111,1826.840,
3128.91089,1214.598,4207.48291,1826.840,
3129.00244,1214.598,4207.57422,1826.840,
3129.09399,1214.598,4207.66553,1827.840,
3129.18530,1214.598,4207.75732,1827.840,
3129.27686,1214.598,4207.84863,1827.840,
3129.36841,1214.598,4207.94043,1828.840,
3129.45996,1214.598,4208.03174,1828.840,
3129.55151,1215.598,4208.12354,1828.840,
3129.64307,1215.598,4208.21484,1829.840,
3129.73462,1215.598,4208.30664,1830.840,
3129.82617,1215.598,4208.39795,1829.840,
3129.91748,1215.598,4208.48926,1830.840,
3130.00903,1216.598,4208.58105,1830.840,
3130.10059,1217.598,4208.67236,1830.840,
3130.19214,1217.598,4208.76416,1830.840,
3130.28369,1216.598,4208.85547,1830.840,
3130.37524,1217.598,4208.94727,1830.840,
3130.46680,1218.598,4209.03857,1831.840,
3130.55835,1218.598,4209.12988,1831.840,
3130.64966,1218.598,4209.22168,1831.840,
3130.74121,1218.598,4209.31299,1832.840,
3130.83276,1219.598,4209.40479,1833.840,
3130.92432,1218.598,4209.49609,1833.840,
3131.01587,1219.598,4209.58789,1833.840,
3131.10742,1219.598,4209.67920,1833.840,
3131.19897,1219.598,4209.77051,1834.840,
3131.29028,1219.598,4209.86230,1834.840,
3131.38184,1219.598,4209.95361,1834.840,
3131.47339,1220.598,4210.04541,1835.840,
3131.56494,1220.598,4210.13672,1835.840,
3131.65649,1221.598,4210.22852,1835.840,
3131.74805,1221.598,4210.31982,1836.840,
3131.83960,1221.598,4210.41113,1836.840,
3131.93115,1221.598,4210.50293,1836.840,
3132.02246,1221.598,4210.59424,1836.840,
3132.11401,1222.598,4210.68604,1837.840,
3132.20557,1222.598,4210.77734,1837.840,
3132.29712,1222.598,4210.86914,1838.840,
3132.38867,1222.598,4210.96045,1838.840,
3132.48022,1222.598,4211.05225,1838.840,
3132.57178,1222.598,4211.14355,1838.840,
3132.66333,1223.598,4211.23486,1838.840,
3132.75464,1223.598,4211.32666,1839.840,
3132.84619,1223.598,4211.41797,1839.840,
3132.93774,1223.598,4211.50977,1840.840,
3133.02930,1223.598,4211.60107,1840.840,
3133.12085,1224.598,4211.69287,1840.840,
3133.21240,1224.598,4211.78418,1840.840,
3133.30396,1224.598,4211.87549,1841.840,
3133.39526,1224.598,4211.96729,1841.840,
3133.48682,1225.598,4212.05859,1841.840,
3133.57837,1225.598,4212.15039,1841.840,
3133.66992,1225.598,4212.24170,1841.840,
3133.76147,1226.598,4212.33350,1843.840,
3133.85303,1226.598,4212.42480,1842.840,
3133.94458,1226.598,4212.51611,1843.840,
3134.03613,1226.598,4212.60791,1843.840,
3134.12744,1227.598,4212.69922,1843.840,
3134.21899,1226.598,4212.79102,1843.840,
3134.31055,1227.598,4212.88232,1843.840,
3134.40210,1227.598,4212.97412,1844.840,
3134.49365,1227.598,4213.06543,1844.840,
3134.58521,1227.598,4213.15723,1844.840,
3134.67676,1227.598,4213.24854,1845.840,
3134.76807,1228.598,4213.33984,1845.840,
3134.85962,1228.598,4213.43164,1845.840,
3134.95117,1228.598,4213.52295,1846.840,
3135.04272,1228.598,4213.61475,1846.840,
3135.13428,1229.598,4213.70605,1846.840,
3135.22583,1229.598,4213.79785,1848.840,
3135.31738,1230.598,4213.88916,1847.840,
3135.40894,1229.598,4213.98047,1848.840,
3135.50024,1229.598,4214.07227,1848.840,
3135.59180,1230.598,4214.16357,1848.840,
3135.68335,1230.598,4214.25537,1848.840,
3135.77490,1230.598,4214.34668,1849.840,
3135.86646,1231.598,4214.43848,1849.840,
3135.95801,1231.598,4214.52979,1849.840,
3136.04956,1232.598,4214.62109,1850.840,
3136.14111,1231.598,4214.71289,1850.840,
3136.23242,1232.598,4214.80420,1850.840,
3136.32397,1232.598,4214.89600,1851.840,
3136.41553,1232.598,4214.98730,1851.840,
3136.50708,1232.598,4215.07910,1851.840,
3136.59863,1232.598,4215.17041,1851.840,
3136.69019,1232.598,4215.26221,1852.840,
3136.78174,1233.598,4215.35352,1851.840,
3136.87305,1233.598,4215.44482,1853.840,
3136.96460,1233.598,4215.53662,1853.840,
3137.05615,1234.598,4215.62793,1853.840,
3137.14771,1234.598,4215.71973,1853.840,
3137.23926,1234.598,4215.81104,1854.840,
3137.33081,1234.598,4215.90283,1854.840,
3137.42236,1234.598,4215.99414,1855.840,
3137.51392,1235.598,4216.08545,1855.840,
3137.60522,1235.598,4216.17725,1855.840,
3137.69678,1235.598,4216.26855,1856.840,
3137.78833,1235.598,4216.36035,1856.840,
3137.87988,1235.598,4216.45166,1856.840,
3137.97144,1236.598,4216.54346,1857.840,
3138.06299,1236.598,4216.63477,1857.840,
3138.15454,1236.598,4216.72607,1858.840,
3138.24609,1236.598,4216.81787,1858.840,
3138.33740,1237.598,4216.90918,1859.840,
3138.42896,1237.598,4217.00098,1858.840,
3138.52051,1237.598,4217.09229,1858.840,
3138.61206,1237.598,4217.18408,1859.840,
3138.70361,1237.598,4217.27539,1859.840,
3138.79517,1237.598,4217.36719,1859.840,
3138.88672,1238.598,4217.45850,1859.840,
3138.97803,1239.598,4217.54980,1859.840,
3139.06958,1239.598,4217.64160,1860.840,
3139.16113,1239.598,4217.73291,1860.840,
3139.25269,1239.598,4217.82471,1860.840,
3139.34424,1239.598,4217.91602,1860.840,
3139.43579,1239.598,4218.00781,1861.840,
3139.52734,1240.598,4218.09912,1861.840,
3139.61890,1239.598,4218.19043,1862.840,
3139.71021,1240.598,4218.28223,1861.840,
3139.80176,1240.598,4218.37354,1862.840,
3139.89331,1240.598,4218.46533,1862.840,
3139.98486,1241.598,4218.55664,1862.840,
3140.07642,1241.598,4218.64844,1863.840,
3140.16797,1241.598,4218.73975,1863.840,
3140.25952,1241.598,4218.83105,1864.840,
3140.35083,1241.598,4218.92285,1863.840,
3140.44238,1242.598,4219.01416,1864.840,
3140.53394,1242.598,4219.10596,1864.840,
3140.62549,1242.598,4219.19727,1864.840,
3140.71704,1243.598,4219.28906,1865.840,
3140.80859,1243.598,4219.38037,1866.840,
3140.90015,1243.598,4219.47217,1866.840,
3140.99170,1243.598,4219.56348,1866.840,
3141.08301,1244.598,4219.65479,1867.840,
3141.17456,1243.598,4219.74658,1866.840,
3141.26611,1244.598,4219.83789,1867.840,
3141.35767,1244.598,4219.92969,1867.840,
3141.44922,1245.598,4220.02100,1867.840,
3141.54077,1244.598,4220.11279,1867.840,
3141.63232,1245.598,4220.20410,1868.840,
3141.72388,1245.598,4220.29541,1869.840,
3141.81519,1245.598,4220.38721,1868.840,
3141.90674,1246.598,4220.47852,1868.840,
3141.99829,1246.598,4220.57031,1869.840,
3142.08984,1246.598,4220.66162,1870.840,
3142.18140,1246.598,4220.75342,1870.840,
3142.27295,1246.598,4220.84473,1870.840,
3142.36450,1247.598,4220.93604,1870.840,
3142.45581,1247.598,4221.02783,1870.840,
3142.54736,1247.598,4221.11914,1872.840,
3142.63892,1247.598,4221.21094,1872.840,
3142.73047,1247.598,4221.30225,1871.840,
3142.82202,1248.598,4221.39404,1873.840,
3142.91357,1248.598,4221.48535,1873.840,
3143.00513,1248.598,4221.57666,1873.840,
3143.09668,1248.598,4221.66846,1873.840,
3143.18799,1248.598,4221.75977,1873.840,
3143.27954,1249.598,4221.85156,1874.840,
3143.37109,1249.598,4221.94287,1874.840,
3143.46265,1249.598,4222.03467,1874.840,
3143.55420,1249.598,4222.12598,1875.840,
3143.64575,1250.598,4222.21777,1875.840,
3143.73730,1250.598,4222.30908,1875.840,
3143.82886,1250.598,4222.40039,1875.840,
3143.92017,1250.598,4222.49219,1876.840,
3144.01172,1250.598,4222.58350,1876.840,
3144.10327,1251.598,4222.67529,1877.840,
3144.19482,1251.598,4222.76660,1876.840,
3144.28638,1251.598,4222.85840,1877.840,
3144.37793,1251.598,4222.94971,1877.840,
3144.46948,1252.598,4223.04102,1877.840,
3144.56079,1252.598,4223.13281,1878.840,
3144.65234,1253.598,4223.22412,1878.840,
3144.74390,1254.598,4223.31592,1878.840,
3144.83545,1254.598,4223.40723,1878.840,
3144.92700,1255.598,4223.49902,1879.840,
3145.01855,1255.598,4223.59033,1879.840,
3145.11011,1256.598,4223.68164,1879.840,
3145.20166,1256.598,4223.77344,1880.840,
3145.29297,1256.598,4223.86475,1880.840,
3145.38452,1256.598,4223.95654,1880.840,
3145.47607,1256.598,4224.04785,1881.840,
3145.56763,1257.598,4224.13965,1881.840,
3145.65918,1256.598,4224.23096,1881.840,
3145.75073,1256.598,4224.32275,1882.840,
3145.84229,1257.598,4224.41406,1882.840,
3145.93359,1257.598,4224.50537,1882.840,
3146.02515,1257.598,4224.59717,1882.840,
3146.11670,1257.598,4224.68848,1883.840,
3146.20825,1257.598,4224.78027,1883.840,
3146.29980,1257.598,4224.87158,1883.840,
3146.39136,1257.598,4224.96338,1884.840,
3146.48291,1257.598,4225.05469,1884.840,
3146.57446,1257.598,4225.14600,1884.840,
3146.66577,1257.598,4225.23779,1885.840,
3146.75732,1257.598,4225.32910,1884.840,
3146.84888,1257.598,4225.42090,1886.840,
3146.94043,1257.598,4225.51221,1886.840,
3147.03198,1257.598,4225.60400,1886.840,
3147.12354,1257.598,4225.69531,1886.840,
3147.21509,1257.598,4225.78662,1885.840,
3147.30664,1257.598,4225.87842,1887.840,
3147.39795,1256.598,4225.96973,1887.840,
3147.48950,1256.598,4226.06152,1887.840,
3147.58105,1256.598,4226.15283,1888.840,
3147.67261,1257.598,4226.24463,1887.840,
3147.76416,1258.598,4226.33594,1888.840,
3147.85571,1257.598,4226.42773,1889.840,
3147.94727,1257.598,4226.51904,1889.840,
3148.03857,1258.598,4226.61035,1889.840,
3148.13013,1259.598,4226.70215,1889.840,
3148.22168,1259.598,4226.79346,1889.840,
3148.31323,1259.598,4226.88525,1890.840,
3148.40479,1259.598,4226.97656,1891.840,
3148.49634,1260.598,4227.06836,1891.840,
3148.58789,1260.598,4227.15967,1892.840,
3148.67944,1261.598,4227.25098,1892.840,
3148.77075,1261.598,4227.34277,1892.840,
3148.86230,1262.598,4227.43408,1892.840,
3148.95386,1262.598,4227.52588,1893.840,
3149.04541,1263.598,4227.61719,1893.840,
3149.13696,1263.598,4227.70898,1893.840,
3149.22852,1264.598,4227.80029,1894.840,
3149.32007,1263.598,4227.89160,1894.840,
3149.41162,1263.598,4227.98340,1894.840,
3149.50293,1264.598,4228.07471,1894.840,
3149.59448,1264.598,4228.16650,1894.840,
3149.68604,1264.598,4228.25781,1894.840,
3149.77759,1265.598,4228.34961,1895.840,
3149.86914,1265.598,4228.44092,1896.840,
3149.96069,1265.598,4228.53271,1895.840,
3150.05225,1265.598,4228.62402,1896.840,
3150.14355,1266.598,4228.71533,1896.840,
3150.23511,1266.598,4228.80713,1896.840,
3150.32666,1266.598,4228.89844,1897.840,
3150.41821,1267.598,4228.99023,1897.840,
3150.50977,1267.598,4229.08154,1897.840,
3150.60132,1267.598,4229.17334,1898.840,
3150.69287,1268.598,4229.26465,1898.840,
3150.78442,1267.598,4229.35596,1898.840,
3150.87573,1267.598,4229.44775,1898.840,
3150.96729,1268.598,4229.53906,1899.840,
3151.05884,1268.598,4229.63086,1899.840,
3151.15039,1268.598,4229.72217,1899.840,
3151.24194,1268.598,4229.81396,1900.840,
3151.33350,1269.598,4229.90527,1901.840,
3151.42505,1269.598,4229.99658,1900.840,
3151.51660,1269.598,4230.08838,1901.840,
3151.60791,1269.598,4230.17969,1901.840,
3151.69946,1269.598,4230.27148,1901.840,
3151.79102,1269.598,4230.36279,1902.840,
3151.88257,1270.598,4230.45459,1902.840,
3151.97412,1270.598,4230.54590,1902.840,
3152.06567,1270.598,4230.63770,1903.840,
3152.15723,1271.598,4230.72900,1903.840,
3152.24854,1271.598,4230.82031,1904.840,
3152.34009,1271.598,4230.91211,1903.840,
3152.43164,1272.598,4231.00342,1904.840,
3152.52319,1272.598,4231.09521,1904.840,
3152.61475,1272.598,4231.18652,1905.840,
3152.70630,1272.598,4231.27832,1904.840,
3152.79785,1272.598,4231.36963,1905.840,
3152.88940,1273.598,4231.46094,1905.840,
3152.98071,1272.598,4231.55273,1905.840,
3153.07227,1273.598,4231.64404,1906.840,
3153.16382,1273.598,4231.73584,1906.840,
3153.25537,1273.598,4231.82715,1906.840,
3153.34692,1274.598,4231.91895,1906.840,
3153.43848,1274.598,4232.01025,1907.840,
3153.53003,1274.598,4232.10156,1907.840,
3153.62134,1275.598,4232.19336,1907.840,
3153.71289,1275.598,4232.28467,1907.840,
3153.80444,1275.598,4232.37646,1908.840,
3153.89600,1275.598,4232.46777,1908.840,
3153.98755,1276.598,4232.55957,1908.840,
3154.07910,1275.598,4232.65088,1908.840,
3154.17065,1275.598,4232.74268,1909.840,
3154.26221,1276.598,4232.83398,1910.840,
3154.35352,1277.598,4232.92529,1910.840,
3154.44507,1276.598,4233.01709,1910.840,
3154.53662,1277.598,4233.10840,1910.840,
3154.62817,1277.598,4233.20020,1911.840,
3154.71973,1277.598,4233.29150,1911.840,
3154.81128,1277.598,4233.38330,1912.840,
3154.90283,1278.598,4233.47461,1912.840,
3154.99438,1278.598,4233.56592,1912.840,
3155.08569,1279.598,4233.65771,1912.840,
3155.17725,1279.598,4233.74902,1913.840,
3155.26880,1279.598,4233.84082,1913.840,
3155.36035,1279.598,4233.93213,1914.840,
3155.45190,1279.598,4234.02393,1914.840,
3155.54346,1280.598,4234.11523,1914.840,
3155.63501,1280.598,4234.20654,1915.840,
3155.72632,1280.598,4234.29834,1916.840,
3155.81787,1280.598,4234.38965,1916.840,
3155.90942,1281.598,4234.48145,1916.840,
3156.00098,1281.598,4234.57275,1917.840,
3156.09253,1281.598,4234.66455,1917.840,
3156.18408,1281.598,4234.75586,1918.840,
3156.27563,1281.598,4234.84717,1918.840,
3156.36719,1281.598,4234.93896,1919.840,
3156.45850,1282.598,4235.03027,1918.840,
3156.55005,1282.598,4235.12207,1919.840,
3156.64160,1282.598,4235.21338,1918.840,
3156.73315,1282.598,4235.30518,1919.840,
3156.82471,1283.598,4235.39648,1919.840,
3156.91626,1282.598,4235.48828,1919.840,
3157.00781,1283.598,4235.57959,1920.840,
3157.09937,1283.598,4235.67090,1920.840,
3157.19067,1284.598,4235.76270,1920.840,
3157.28223,1284.598,4235.85400,1921.840,
3157.37378,1284.598,4235.94580,1921.840,
3157.46533,1284.598,4236.03711,1920.840,
3157.55688,1284.598,4236.12891,1921.840,
3157.64844,1284.598,4236.22021,1921.840,
3157.73999,1285.598,4236.31152,1921.840,
3157.83130,1284.598,4236.40332,1922.840,
3157.92285,1285.598,4236.49463,1922.840,
3158.01440,1286.598,4236.58643,1922.840,
3158.10596,1285.598,4236.67773,1922.840,
3158.19751,1286.598,4236.76953,1923.840,
3158.28906,1286.598,4236.86084,1923.840,
3158.38062,1287.598,4236.95215,1924.840,
3158.47217,1287.598,4237.04395,1924.840,
3158.56348,1287.598,4237.13525,1924.840,
3158.65503,1287.598,4237.22705,1925.840,
3158.74658,1287.598,4237.31836,1925.840,
3158.83813,1287.598,4237.41016,1925.840,
3158.92969,1288.598,4237.50146,1925.840,
3159.02124,1288.598,4237.59326,1926.840,
3159.11279,1288.598,4237.68457,1926.840,
3159.20410,1289.598,4237.77588,1927.840,
3159.29565,1288.598,4237.86768,1927.840,
3159.38721,1289.598,4237.95898,1927.840,
3159.47876,1290.598,4238.05078,1927.840,
3159.57031,1289.598,4238.14209,1928.840,
3159.66187,1290.598,4238.23389,1928.840,
3159.75342,1291.598,4238.32520,1928.840,
3159.84497,1291.598,4238.41650,1928.840,
3159.93628,1291.598,4238.50830,1929.840,
3160.02783,1291.598,4238.59961,1929.840,
3160.11938,1291.598,4238.69141,1929.840,
3160.21094,1291.598,4238.78271,1929.840,
3160.30249,1291.598,4238.87451,1930.840,
3160.39404,1291.598,4238.96582,1930.840,
3160.48560,1292.598,4239.05713,1931.840,
3160.57715,1292.598,4239.14893,1931.840,
3160.66846,1293.598,4239.24023,1931.840,
3160.76001,1293.598,4239.33203,1931.840,
3160.85156,1293.598,4239.42334,1932.840,
3160.94312,1294.598,4239.51514,1932.840,
3161.03467,1294.598,4239.60645,1932.840,
3161.12622,1294.598,4239.69824,1933.840,
3161.21777,1294.598,4239.78955,1933.840,
3161.30908,1294.598,4239.88086,1933.840,
3161.40063,1295.598,4239.97266,1934.840,
3161.49219,1295.598,4240.06396,1934.840,
3161.58374,1294.598,4240.15576,1935.840,
3161.67529,1295.598,4240.24707,1934.840,
3161.76685,1295.598,4240.33887,1935.840,
3161.85840,1296.598,4240.43018,1935.840,
3161.94995,1295.598,4240.52148,1936.840,
3162.04126,1295.598,4240.61328,1936.840,
3162.13281,1296.598,4240.70459,1936.840,
3162.22437,1296.598,4240.79639,1936.840,
3162.31592,1296.598,4240.88770,1937.840,
3162.40747,1297.598,4240.97949,1937.840,
3162.49902,1297.598,4241.07080,1937.840,
3162.59058,1297.598,4241.16211,1937.840,
3162.68213,1297.598,4241.25391,1938.840,
3162.77344,1298.598,4241.34521,1938.840,
3162.86499,1298.598,4241.43701,1938.840,
3162.95654,1299.598,4241.52832,1938.840,
3163.04810,1299.598,4241.62012,1940.840,
3163.13965,1299.598,4241.71143,1939.840,
3163.23120,1300.598,4241.80322,1940.840,
3163.32275,1300.598,4241.89453,1940.840,
3163.41406,1301.598,4241.98584,1940.840,
3163.50562,1301.598,4242.07764,1940.840,
3163.59717,1301.598,4242.16895,1941.840,
3163.68872,1302.598,4242.26074,1941.840,
3163.78027,1301.598,4242.35205,1941.840,
3163.87183,1301.598,4242.44385,1942.840,
3163.96338,1301.598,4242.53516,1942.840,
3164.05493,1303.598,4242.62646,1942.840,
3164.14624,1302.598,4242.71826,1943.840,
3164.23779,1302.598,4242.80957,1943.840,
3164.32935,1303.598,4242.90137,1943.840,
3164.42090,1302.598,4242.99268,1944.840,
3164.51245,1303.598,4243.08447,1945.840,
3164.60400,1303.598,4243.17578,1944.840,
3164.69556,1303.598,4243.26709,1945.840,
3164.78687,1303.598,4243.35889,1945.840,
3164.87842,1303.598,4243.45020,1945.840,
3164.96997,1303.598,4243.54199,1946.840,
3165.06152,1303.598,4243.63330,1946.840,
3165.15308,1304.598,4243.72510,1947.840,
3165.24463,1304.598,4243.81641,1946.840,
3165.33618,1304.598,4243.90820,1947.840,
3165.42773,1304.598,4243.99951,1947.840,
3165.51904,1304.598,4244.09082,1947.840,
3165.61060,1303.598,4244.18262,1947.840,
3165.70215,1302.598,4244.27393,1948.840,
3165.79370,1303.598,4244.36572,1948.840,
3165.88525,1302.598,4244.45703,1948.840,
3165.97681,1303.598,4244.54883,1949.840,
3166.06836,1302.598,4244.64014,1949.840,
3166.15991,1303.598,4244.73145,1949.840,
3166.25122,1303.598,4244.82324,1949.840,
3166.34277,1303.598,4244.91455,1950.840,
3166.43433,1304.598,4245.00635,1950.840,
3166.52588,1304.598,4245.09766,1951.840,
3166.61743,1305.598,4245.18945,1951.840,
3166.70898,1306.598,4245.28076,1951.840,
3166.80054,1307.598,4245.37207,1952.840,
3166.89185,1307.598,4245.46387,1952.840,
3166.98340,1307.598,4245.55518,1952.840,
3167.07495,1307.598,4245.64697,1952.840,
3167.16650,1308.598,4245.73828,1953.840,
3167.25806,1308.598,4245.83008,1953.840,
3167.34961,1309.598,4245.92139,1954.840,
3167.44116,1309.598,4246.01270,1954.840,
3167.53271,1309.598,4246.10449,1954.840,
3167.62402,1310.598,4246.19580,1954.840,
3167.71558,1310.598,4246.28760,1955.840,
3167.80713,1310.598,4246.37891,1955.840,
3167.89868,1311.598,4246.47070,1955.840,
3167.99023,1311.598,4246.56201,1956.840,
3168.08179,1311.598,4246.65381,1956.840,
3168.17334,1311.598,4246.74512,1956.840,
3168.26489,1312.598,4246.83643,1957.840,
3168.35620,1312.598,4246.92822,1957.840,
3168.44775,1312.598,4247.01953,1957.840,
3168.53931,1313.598,4247.11133,1957.840,
3168.63086,1313.598,4247.20264,1957.840,
3168.72241,1313.598,4247.29443,1958.840,
3168.81396,1313.598,4247.38574,1958.840,
3168.90552,1313.598,4247.47705,1959.840,
3168.99683,1314.598,4247.56885,1959.840,
3169.08838,1314.598,4247.66016,1959.840,
3169.17993,1314.598,4247.75195,1959.840,
3169.27148,1314.598,4247.84326,1959.840,
3169.36304,1314.598,4247.93506,1960.840,
3169.45459,1315.598,4248.02637,1960.840,
3169.54614,1315.598,4248.11768,1961.840,
3169.63770,1315.598,4248.20947,1961.840,
3169.72900,1316.598,4248.30078,1961.840,
3169.82056,1316.598,4248.39258,1962.840,
3169.91211,1316.598,4248.48389,1962.840,
3170.00366,1317.598,4248.57568,1962.840,
3170.09521,1316.598,4248.66699,1963.840,
3170.18677,1317.598,4248.75879,1963.840,
3170.27832,1317.598,4248.85010,1963.840,
3170.36987,1318.598,4248.94141,1964.840,
3170.46118,1317.598,4249.03320,1964.840,
3170.55273,1317.598,4249.12451,1964.840,
3170.64429,1318.598,4249.21631,1964.840,
3170.73584,1318.598,4249.30762,1965.840,
3170.82739,1318.598,4249.39941,1965.840,
3170.91895,1319.598,4249.49072,1965.840,
3171.01050,1320.598,4249.58203,1965.840,
3171.10181,1319.598,4249.67383,1966.840,
3171.19336,1320.598,4249.76514,1966.840,
3171.28491,1320.598,4249.85693,1966.840,
3171.37646,1320.598,4249.94824,1967.840,
3171.46802,1320.598,4250.04004,1967.840,
3171.55957,1320.598,4250.13135,1967.840,
3171.65112,1321.598,4250.22266,1967.840,
3171.74268,1321.598,4250.31445,1968.840,
3171.83398,1321.598,4250.40576,1969.840,
3171.92554,1321.598,4250.49756,1969.840,
3172.01709,1322.598,4250.58887,1969.840,
3172.10864,1322.598,4250.68066,1969.840,
3172.20020,1322.598,4250.77197,1969.840,
3172.29175,1322.598,4250.86377,1970.840,
3172.38330,1322.598,4250.95508,1970.840,
3172.47461,1322.598,4251.04639,1970.840,
3172.56616,1323.598,4251.13818,1971.840,
3172.65771,1324.598,4251.22949,1971.840,
3172.74927,1323.598,4251.32129,1971.840,
3172.84082,1324.598,4251.41260,1972.840,
3172.93237,1323.598,4251.50439,1972.840,
3173.02393,1324.598,4251.59570,1972.840,
3173.11548,1325.598,4251.68701,1972.840,
3173.20679,1325.598,4251.77881,1972.840,
3173.29834,1325.598,4251.87012,1973.840,
3173.38989,1325.598,4251.96191,1973.840,
3173.48145,1325.598,4252.05322,1974.840,
3173.57300,1325.598,4252.14502,1974.840,
3173.66455,1326.598,4252.23633,1975.840,
3173.75610,1326.598,4252.32764,1975.840,
3173.84766,1326.598,4252.41943,1975.840,
3173.93896,1326.598,4252.51074,1975.840,
3174.03052,1327.598,4252.60254,1975.840,
3174.12207,1327.598,4252.69385,1975.840,
3174.21362,1327.598,4252.78564,1975.840,
3174.30518,1328.598,4252.87695,1976.840,
3174.39673,1327.598,4252.96875,1976.840,
3174.48828,1328.598,4253.06006,1976.840,
3174.57959,1328.598,4253.15137,1976.840,
3174.67114,1328.598,4253.24316,1977.840,
3174.76270,1328.598,4253.33447,1977.840,
3174.85425,1328.598,4253.42627,1978.840,
3174.94580,1329.598,4253.51758,1978.840,
3175.03735,1329.598,4253.60938,1978.840,
3175.12891,1330.598,4253.70068,1978.840,
3175.22046,1330.598,4253.79199,1979.840,
3175.31177,1330.598,4253.88379,1979.840,
3175.40332,1330.598,4253.97510,1979.840,
3175.49487,1330.598,4254.06689,1980.840,
3175.58643,1331.598,4254.15820,1980.840,
3175.67798,1331.598,4254.25000,1980.840,
3175.76953,1331.598,4254.34131,1981.840,
3175.86108,1332.598,4254.43262,1981.840,
3175.95264,1331.598,4254.52441,1981.840,
3176.04395,1332.598,4254.61572,1982.840,
3176.13550,1332.598,4254.70752,1982.840,
3176.22705,1332.598,4254.79883,1983.840,
3176.31860,1333.598,4254.89063,1982.840,
3176.41016,1333.598,4254.98193,1983.840,
3176.50171,1333.598,4255.07373,1983.840,
3176.59326,1333.598,4255.16504,1984.840,
3176.68457,1333.598,4255.25635,1984.840,
3176.77612,1334.598,4255.34814,1984.840,
3176.86768,1334.598,4255.43945,1984.840,
3176.95923,1335.598,4255.53125,1984.840,
3177.05078,1335.598,4255.62256,1985.840,
3177.14233,1335.598,4255.71436,1985.840,
3177.23389,1335.598,4255.80566,1985.840,
3177.32544,1335.598,4255.89697,1986.840,
3177.41675,1335.598,4255.98877,1986.840,
3177.50830,1335.598,4256.08008,1986.840,
3177.59985,1335.598,4256.17188,1987.840,
3177.69141,1336.598,4256.26318,1987.840,
3177.78296,1336.598,4256.35498,1987.840,
3177.87451,1336.598,4256.44629,1987.840,
3177.96606,1337.598,4256.53760,1988.840,
3178.05737,1336.598,4256.62939,1988.840,
3178.14893,1337.598,4256.72070,1988.840,
3178.24048,1337.598,4256.81250,1989.840,
3178.33203,1338.598,4256.90381,1989.840,
3178.42358,1337.598,4256.99561,1989.840,
3178.51514,1338.598,4257.08691,1990.840,
3178.60669,1338.598,4257.17871,1990.840,
3178.69824,1338.598,4257.27002,1990.840,
3178.78955,1338.598,4257.36133,1990.840,
3178.88110,1339.598,4257.45313,1991.840,
3178.97266,1339.598,4257.54443,1991.840,
3179.06421,1339.598,4257.63623,1991.840,
3179.15576,1340.598,4257.72754,1992.840,
3179.24731,1340.598,4257.81934,1992.840,
3179.33887,1340.598,4257.91064,1992.840,
3179.43042,1340.598,4258.00195,1993.840,
3179.52173,1341.598,4258.09375,1993.840,
3179.61328,1341.598,4258.18506,1993.840,
3179.70483,1341.598,4258.27686,1993.840,
3179.79639,1341.598,4258.36816,1994.840,
3179.88794,1341.598,4258.45996,1994.840,
3179.97949,1343.598,4258.55127,1994.840,
3180.07104,1342.598,4258.64258,1994.840,
3180.16235,1342.598,4258.73438,1994.840,
3180.25391,1343.598,4258.82568,1995.840,
3180.34546,1343.598,4258.91748,1995.840,
3180.43701,1343.598,4259.00879,1996.840,
3180.52856,1343.598,4259.10059,1996.840,
3180.62012,1344.598,4259.19189,1997.840,
3180.71167,1344.598,4259.28320,1996.840,
3180.80322,1343.598,4259.37500,1997.840,
3180.89453,1344.598,4259.46631,1997.840,
3180.98608,1344.598,4259.55811,1998.840,
3181.07764,1344.598,4259.64941,1998.840,
3181.16919,1345.598,4259.74121,1998.840,
3181.26074,1345.598,4259.83252,1998.840,
3181.35229,1345.598,4259.92432,1999.840,
3181.44385,1346.598,4260.01563,1999.840,
3181.53540,1346.598,4260.10693,1999.840,
3181.62671,1347.598,4260.19873,2000.840,
3181.71826,1347.598,4260.29004,2000.840,
3181.80981,1347.598,4260.38184,2000.840,
3181.90137,1348.598,4260.47314,2000.840,
3181.99292,1348.598,4260.56494,2000.840,
3182.08447,1349.598,4260.65625,2002.840,
3182.17603,1349.598,4260.74756,2002.840,
3182.26733,1349.598,4260.83936,2002.840,
3182.35889,1349.598,4260.93066,2002.840,
3182.45044,1349.598,4261.02246,2002.840,
3182.54199,1350.598,4261.11377,2002.840,
3182.63354,1350.598,4261.20557,2003.840,
3182.72510,1350.598,4261.29688,2003.840,
3182.81665,1350.598,4261.38818,2004.840,
3182.90820,1351.598,4261.47998,2003.840,
3182.99951,1351.598,4261.57129,2004.840,
3183.09106,1351.598,4261.66309,2004.840,
3183.18262,1351.598,4261.75439,2005.840,
3183.27417,1351.598,4261.84619,2005.840,
3183.36572,1351.598,4261.93750,2006.840,
3183.45728,1351.598,4262.02930,2006.840,
3183.54883,1351.598,4262.12061,2007.840,
3183.64014,1351.598,4262.21191,2007.840,
3183.73169,1351.598,4262.30371,2007.840,
3183.82324,1351.598,4262.39502,2007.840,
3183.91479,1350.598,4262.48682,2008.840,
3184.00635,1350.598,4262.57813,2008.840,
3184.09790,1349.598,4262.66992,2008.840,
3184.18945,1348.598,4262.76123,2008.840,
3184.28101,1349.598,4262.85254,2009.840,
3184.37231,1349.598,4262.94434,2009.840,
3184.46387,1348.598,4263.03564,2009.840,
3184.55542,1349.598,4263.12744,2009.840,
3184.64697,1349.598,4263.21875,2009.840,
3184.73853,1350.598,4263.31055,2010.840,
3184.83008,1350.598,4263.40186,2011.840,
3184.92163,1351.598,4263.49316,2010.840,
3185.01318,1351.598,4263.58496,2011.840,
3185.10449,1352.598,4263.67627,2011.840,
3185.19604,1353.598,4263.76807,2011.840,
3185.28760,1353.598,4263.85938,2012.840,
3185.37915,1353.598,4263.95117,2012.840,
3185.47070,1354.598,4264.04248,2013.840,
3185.56226,1355.598,4264.13428,2013.840,
3185.65381,1355.598,4264.22559,2013.840,
3185.74512,1355.598,4264.31689,2013.840,
3185.83667,1356.598,4264.40869,2013.840,
3185.92822,1356.598,4264.50000,2014.840,
3186.01978,1356.598,4264.59180,2014.840,
3186.11133,1357.598,4264.68311,2014.840,
3186.20288,1357.598,4264.77490,2014.840,
3186.29443,1357.598,4264.86621,2015.840,
3186.38599,1358.598,4264.95752,2015.840,
3186.47729,1358.598,4265.04932,2016.840,
3186.56885,1358.598,4265.14063,2016.840,
3186.66040,1359.598,4265.23242,2016.840,
3186.75195,1359.598,4265.32373,2017.840,
3186.84351,1359.598,4265.41553,2017.840,
3186.93506,1359.598,4265.50684,2017.840,
3187.02661,1359.598,4265.59814,2018.840,
3187.11816,1359.598,4265.68994,2018.840,
3187.20947,1360.598,4265.78125,2018.840,
3187.30103,1361.598,4265.87305,2018.840,
3187.39258,1360.598,4265.96436,2018.840,
3187.48413,1361.598,4266.05615,2019.840,
3187.57568,1361.598,4266.14746,2020.840,
3187.66724,1361.598,4266.23926,2019.840,
3187.75879,1360.598,4266.33057,2019.840,
3187.85010,1361.598,4266.42188,2020.840,
3187.94165,1362.598,4266.51367,2021.840,
3188.03320,1362.598,4266.60498,2020.840,
3188.12476,1362.598,4266.69678,2021.840,
3188.21631,1362.598,4266.78809,2021.840,
3188.30786,1362.598,4266.87988,2021.840,
3188.39941,1363.598,4266.97119,2022.840,
3188.49097,1363.598,4267.06250,2022.840,
3188.58228,1364.598,4267.15430,2022.840,
3188.67383,1363.598,4267.24561,2022.840,
3188.76538,1364.598,4267.33740,2023.840,
3188.85693,1364.598,4267.42871,2023.840,
3188.94849,1365.598,4267.52051,2023.840,
3189.04004,1364.598,4267.61182,2024.840,
3189.13159,1365.598,4267.70313,2023.840,
3189.22290,1365.598,4267.79492,2024.840,
3189.31445,1365.598,4267.88623,2025.840,
3189.40601,1366.598,4267.97803,2025.840,
3189.49756,1365.598,4268.06934,2026.840,
3189.58911,1366.598,4268.16113,2025.840,
3189.68066,1366.598,4268.25244,2026.840,
3189.77222,1366.598,4268.34424,2026.840,
3189.86377,1366.598,4268.43555,2026.840,
3189.95508,1367.598,4268.52686,2027.840,
3190.04663,1367.598,4268.61865,2027.840,
3190.13818,1367.598,4268.70996,2028.840,
3190.22974,1368.598,4268.80176,2028.840,
3190.32129,1368.598,4268.89307,2028.840,
3190.41284,1368.598,4268.98486,2028.840,
3190.50439,1368.598,4269.07617,2028.840,
3190.59595,1369.598,4269.16748,2029.840,
3190.68726,1369.598,4269.25928,2029.840,
3190.77881,1369.598,4269.35059,2030.840,
3190.87036,1369.598,4269.44238,2031.840,
3190.96191,1370.598,4269.53369,2031.840,
3191.05347,1369.598,4269.62549,2031.840,
3191.14502,1370.598,4269.71680,2031.840,
3191.23657,1370.598,4269.80811,2031.840,
3191.32788,1370.598,4269.89990,2032.840,
3191.41943,1370.598,4269.99121,2032.840,
3191.51099,1370.598,4270.08301,2033.840,
3191.60254,1370.598,4270.17432,2033.840,
3191.69409,1372.598,4270.26611,2033.840,
3191.78564,1371.598,4270.35742,2034.840,
3191.87720,1371.598,4270.44922,2034.840,
3191.96875,1372.598,4270.54053,2034.840,
3192.06006,1372.598,4270.63184,2034.840,
3192.15161,1373.598,4270.72363,2034.840,
3192.24316,1372.598,4270.81494,2034.840,
3192.33472,1373.598,4270.90674,2035.840,
3192.42627,1373.598,4270.99805,2035.840,
3192.51782,1373.598,4271.08984,2035.840,
3192.60938,1373.598,4271.18115,2036.840,
3192.70093,1374.598,4271.27246,2036.840,
3192.79224,1374.598,4271.36426,2036.840,
3192.88379,1374.598,4271.45557,2036.840,
3192.97534,1375.598,4271.54736,2036.840,
3193.06689,1374.598,4271.63867,2037.840,
3193.15845,1375.598,4271.73047,2037.840,
3193.25000,1375.598,4271.82178,2038.840,
3193.34155,1375.598,4271.91309,2038.840,
3193.43286,1376.598,4272.00488,2038.840,
3193.52441,1376.598,4272.09619,2038.840,
3193.61597,1376.598,4272.18799,2038.840,
3193.70752,1376.598,4272.27930,2039.840,
3193.79907,1377.598,4272.37109,2039.840,
3193.89063,1377.598,4272.46240,2040.840,
3193.98218,1377.598,4272.55371,2040.840,
3194.07373,1377.598,4272.64551,2040.840,
3194.16504,1378.598,4272.73682,2041.840,
3194.25659,1378.598,4272.82861,2041.840,
3194.34814,1378.598,4272.91992,2041.840,
3194.43970,1378.598,4273.01172,2041.840,
3194.53125,1378.598,4273.10303,2042.840,
3194.62280,1379.598,4273.19482,2042.840,
3194.71436,1379.598,4273.28613,2042.840,
3194.80591,1379.598,4273.37744,2042.840,
3194.89722,1379.598,4273.46924,2042.840,
3194.98877,1379.598,4273.56055,2043.840,
3195.08032,1380.598,4273.65234,2044.840,
3195.17188,1380.598,4273.74365,2044.840,
3195.26343,1380.598,4273.83545,2045.840,
3195.35498,1381.598,4273.92676,2045.840,
3195.44653,1380.598,4274.01807,2045.840,
3195.53784,1381.598,4274.10986,2045.840,
3195.62939,1381.598,4274.20117,2046.840,
3195.72095,1381.598,4274.29297,2046.840,
3195.81250,1382.598,4274.38428,2046.840,
3195.90405,1382.598,4274.47607,2046.840,
3195.99561,1382.598,4274.56738,2047.840,
3196.08716,1383.598,4274.65869,2047.840,
3196.17871,1383.598,4274.75049,2048.840,
3196.27002,1384.598,4274.84180,2047.840,
3196.36157,1384.598,4274.93359,2048.840,
3196.45313,1383.598,4275.02490,2047.840,
3196.54468,1384.598,4275.11670,2049.840,
3196.63623,1384.598,4275.20801,2048.840,
3196.72778,1385.598,4275.29980,2050.840,
3196.81934,1384.598,4275.39111,2049.840,
3196.91064,1385.598,4275.48242,2050.840,
3197.00220,1385.598,4275.57422,2050.840,
3197.09375,1385.598,4275.66553,2050.840,
3197.18530,1385.598,4275.75732,2050.840,
3197.27686,1386.598,4275.84863,2051.840,
3197.36841,1385.598,4275.94043,2051.840,
3197.45996,1386.598,4276.03174,2051.840,
3197.55151,1387.598,4276.12305,2051.840,
3197.64282,1387.598,4276.21484,2052.840,
3197.73438,1387.598,4276.30615,2052.840,
3197.82593,1387.598,4276.39795,2053.840,
3197.91748,1387.598,4276.48926,2052.840,
3198.00903,1387.598,4276.58105,2053.840,
3198.10059,1387.598,4276.67236,2053.840,
3198.19214,1388.598,4276.76367,2054.840,
3198.28369,1388.598,4276.85547,2054.840,
3198.37500,1388.598,4276.94678,2055.840,
3198.46655,1388.598,4277.03857,2054.840,
3198.55811,1389.598,4277.12988,2055.840,
3198.64966,1389.598,4277.22168,2055.840,
3198.74121,1389.598,4277.31299,2056.840,
3198.83276,1390.598,4277.40479,2056.840,
3198.92432,1389.598,4277.49609,2056.840,
3199.01563,1390.598,4277.58740,2056.840,
3199.10718,1390.598,4277.67920,2057.840,
3199.19873,1391.598,4277.77051,2057.840,
3199.29028,1391.598,4277.86230,2057.840,
3199.38184,1391.598,4277.95361,2057.840,
3199.47339,1391.598,4278.04541,2058.840,
3199.56494,1391.598,4278.13672,2058.840,
3199.65649,1392.598,4278.22803,2059.840,
3199.74780,1392.598,4278.31982,2059.840,
3199.83936,1392.598,4278.41113,2059.840,
3199.93091,1392.598,4278.50293,2059.840,
3200.02246,1392.598,4278.59424,2060.840,
3200.11401,1392.598,4278.68604,2060.840,
3200.20557,1392.598,4278.77734,2060.840,
3200.29712,1392.598,4278.86865,2061.840,
3200.38867,1391.598,4278.96045,2061.840,
3200.47998,1392.598,4279.05176,2061.840,
3200.57153,1392.598,4279.14355,2061.840,
3200.66309,1393.598,4279.23486,2061.840,
3200.75464,1392.598,4279.32666,2062.840,
3200.84619,1393.598,4279.41797,2062.840,
3200.93774,1393.598,4279.50977,2062.840,
3201.02930,1393.598,4279.60107,2063.840,
3201.12061,1394.598,4279.69238,2064.840,
3201.21216,1394.598,4279.78418,2063.840,
3201.30371,1395.598,4279.87549,2064.840,
3201.39526,1395.598,4279.96729,2064.840,
3201.48682,1395.598,4280.05859,2064.840,
3201.57837,1396.598,4280.15039,2065.840,
3201.66992,1396.598,4280.24170,2065.840,
3201.76147,1396.598,4280.33301,2065.840,
3201.85278,1397.598,4280.42480,2066.840,
3201.94434,1397.598,4280.51611,2066.840,
3202.03589,1398.598,4280.60791,2066.840,
3202.12744,1398.598,4280.69922,2066.840,
3202.21899,1398.598,4280.79102,2067.840,
3202.31055,1398.598,4280.88232,2067.840,
3202.40210,1398.598,4280.97363,2067.840,
3202.49341,1399.598,4281.06543,2067.840,
3202.58496,1398.598,4281.15674,2068.840,
3202.67651,1399.598,4281.24854,2067.840,
3202.76807,1399.598,4281.33984,2069.840,
3202.85962,1399.598,4281.43164,2069.840,
3202.95117,1399.598,4281.52295,2069.840,
3203.04272,1399.598,4281.61475,2069.840,
3203.13428,1400.598,4281.70605,2070.840,
3203.22559,1399.598,4281.79736,2070.840,
3203.31714,1400.598,4281.88916,2070.840,
3203.40869,1401.598,4281.98047,2071.840,
3203.50024,1401.598,4282.07227,2071.840,
3203.59180,1401.598,4282.16357,2071.840,
3203.68335,1401.598,4282.25537,2072.840,
3203.77490,1402.598,4282.34668,2072.840,
3203.86646,1403.598,4282.43799,2072.840,
3203.95776,1402.598,4282.52979,2072.840,
3204.04932,1403.598,4282.62109,2073.840,
3204.14087,1403.598,4282.71289,2073.840,
3204.23242,1404.598,4282.80420,2073.840,
3204.32397,1404.598,4282.89600,2074.840,
3204.41553,1404.598,4282.98730,2074.840,
3204.50708,1404.598,4283.07861,2074.840,
3204.59839,1405.598,4283.17041,2074.840,
3204.68994,1405.598,4283.26172,2075.840,
3204.78149,1405.598,4283.35352,2075.840,
3204.87305,1406.598,4283.44482,2075.840,
3204.96460,1406.598,4283.53662,2076.840,
3205.05615,1406.598,4283.62793,2076.840,
3205.14771,1406.598,4283.71924,2076.840,
3205.23926,1406.598,4283.81104,2076.840,
3205.33057,1406.598,4283.90234,2076.840,
3205.42212,1407.598,4283.99414,2077.840,
3205.51367,1407.598,4284.08545,2078.840,
3205.60522,1407.598,4284.17725,2077.840,
3205.69678,1407.598,4284.26855,2078.840,
3205.78833,1407.598,4284.36035,2078.840,
3205.87988,1408.598,4284.45166,2079.840,
3205.97144,1408.598,4284.54297,2079.840,
3206.06274,1408.598,4284.63477,2079.840,
3206.15430,1408.598,4284.72607,2080.840,
3206.24585,1409.598,4284.81787,2080.840,
3206.33740,1409.598,4284.90918,2079.840,
3206.42896,1409.598,4285.00098,2080.840,
3206.52051,1410.598,4285.09229,2081.840,
3206.61206,1410.598,4285.18359,2081.840,
3206.70337,1410.598,4285.27539,2081.840,
3206.79492,1410.598,4285.36670,2081.840,
3206.88647,1411.598,4285.45850,2081.840,
3206.97803,1411.598,4285.54980,2082.840,
3207.06958,1411.598,4285.64160,2082.840,
3207.16113,1411.598,4285.73291,2082.840,
3207.25269,1412.598,4285.82422,2082.840,
3207.34424,1411.598,4285.91602,2083.840,
3207.43555,1412.598,4286.00732,2083.840,
3207.52710,1412.598,4286.09912,2083.840,
3207.61865,1412.598,4286.19043,2084.840,
3207.71021,1412.598,4286.28223,2084.840,
3207.80176,1414.598,4286.37354,2084.840,
3207.89331,1414.598,4286.46533,2085.840,
3207.98486,1413.598,4286.55664,2085.840,
3208.07617,1414.598,4286.64795,2085.840,
3208.16772,1415.598,4286.73975,2086.840,
3208.25928,1414.598,4286.83105,2086.840,
3208.35083,1415.598,4286.92285,2086.840,
3208.44238,1415.598,4287.01416,2087.840,
3208.53394,1415.598,4287.10596,2087.840,
3208.62549,1416.598,4287.19727,2087.840,
3208.71704,1416.598,4287.28857,2087.840,
3208.80835,1416.598,4287.38037,2088.840,
3208.89990,1416.598,4287.47168,2087.840,
3208.99146,1417.598,4287.56348,2088.840,
3209.08301,1416.598,4287.65479,2089.840,
3209.17456,1417.598,4287.74658,2089.840,
3209.26611,1417.598,4287.83789,2089.840,
3209.35767,1417.598,4287.92920,2090.840,
3209.44922,1417.598,4288.02100,2090.840,
3209.54053,1418.598,4288.11230,2090.840,
3209.63208,1418.598,4288.20410,2091.840,
3209.72363,1418.598,4288.29541,2091.840,
3209.81519,1418.598,4288.38721,2091.840,
3209.90674,1419.598,4288.47852,2092.840,
3209.99829,1419.598,4288.57031,2092.840,
3210.08984,1418.598,4288.66162,2092.840,
3210.18115,1419.598,4288.75293,2092.840,
3210.27271,1420.598,4288.84473,2093.840,
3210.36426,1420.598,4288.93604,2093.840,
3210.45581,1420.598,4289.02783,2093.840,
3210.54736,1420.598,4289.11914,2093.840,
3210.63892,1420.598,4289.21094,2094.840,
3210.73047,1421.598,4289.30225,2093.840,
3210.82202,1421.598,4289.39355,2094.840,
3210.91333,1421.598,4289.48535,2094.840,
3211.00488,1421.598,4289.57666,2095.840,
3211.09644,1421.598,4289.66846,2095.840,
3211.18799,1422.598,4289.75977,2095.840,
3211.27954,1422.598,4289.85156,2095.840,
3211.37109,1422.598,4289.94287,2096.840,
3211.46265,1423.598,4290.03418,2096.840,
3211.55420,1423.598,4290.12598,2097.840,
3211.64551,1423.598,4290.21729,2097.840,
3211.73706,1423.598,4290.30908,2097.840,
3211.82861,1423.598,4290.40039,2098.840,
3211.92017,1423.598,4290.49219,2098.840,
3212.01172,1424.598,4290.58350,2098.840,
3212.10327,1424.598,4290.67529,2098.840,
3212.19482,1425.598,4290.76660,2099.840,
3212.28613,1425.598,4290.85791,2099.840,
3212.37769,1425.598,4290.94971,2099.840,
3212.46924,1425.598,4291.04102,2099.840,
3212.56079,1425.598,4291.13281,2099.840,
3212.65234,1426.598,4291.22412,2100.840,
3212.74390,1426.598,4291.31592,2101.840,
3212.83545,1426.598,4291.40723,2101.840,
3212.92700,1426.598,4291.49854,2101.840,
3213.01831,1427.598,4291.59033,2101.840,
3213.10986,1427.598,4291.68164,2101.840,
3213.20142,1427.598,4291.77344,2101.840,
3213.29297,1427.598,4291.86475,2102.840,
3213.38452,1427.598,4291.95654,2102.840,
3213.47607,1428.598,4292.04785,2103.840,
3213.56763,1428.598,4292.13916,2103.840,
3213.65918,1429.598,4292.23096,2103.840,
3213.75049,1428.598,4292.32227,2103.840,
3213.84204,1429.598,4292.41406,2103.840,
3213.93359,1429.598,4292.50537,2104.840,
3214.02515,1429.598,4292.59717,2104.840,
3214.11670,1430.598,4292.68848,2105.840,
3214.20825,1430.598,4292.78027,2105.840,
3214.29980,1430.598,4292.87158,2106.840,
3214.39111,1430.598,4292.96289,2106.840,
3214.48267,1430.598,4293.05469,2106.840,
3214.57422,1431.598,4293.14600,2106.840,
3214.66577,1431.598,4293.23779,2107.840,
3214.75732,1431.598,4293.32910,2107.840,
3214.84888,1431.598,4293.42090,2107.840,
3214.94043,1431.598,4293.51221,2107.840,
3215.03198,1432.598,4293.60352,2108.840,
3215.12329,1432.598,4293.69531,2108.840,
3215.21484,1432.598,4293.78662,2108.840,
3215.30640,1433.598,4293.87842,2108.840,
3215.39795,1433.598,4293.96973,2109.840,
3215.48950,1433.598,4294.06152,2109.840,
3215.58105,1434.598,4294.15283,2109.840,
3215.67261,1433.598,4294.24414,2109.840,
3215.76392,1434.598,4294.33594,2110.840,
3215.85547,1434.598,4294.42725,2110.840,
3215.94702,1434.598,4294.51904,2110.840,
3216.03857,1434.598,4294.61035,2111.840,
3216.13013,1435.598,4294.70215,2111.840,
3216.22168,1434.598,4294.79346,2111.840,
3216.31323,1435.598,4294.88525,2112.840,
3216.40479,1435.598,4294.97656,2111.840,
3216.49609,1435.598,4295.06787,2112.840,
3216.58765,1436.598,4295.15967,2112.840,
3216.67920,1436.598,4295.25098,2113.840,
3216.77075,1436.598,4295.34277,2113.840,
3216.86230,1437.598,4295.43408,2113.840,
3216.95386,1437.598,4295.52588,2113.840,
3217.04541,1437.598,4295.61719,2113.840,
3217.13696,1437.598,4295.70850,2114.840,
3217.22827,1437.598,4295.80029,2115.840,
3217.31982,1437.598,4295.89160,2114.840,
3217.41138,1438.598,4295.98340,2115.840,
3217.50293,1438.598,4296.07471,2115.840,
3217.59448,1438.598,4296.16650,2115.840,
3217.68604,1439.598,4296.25781,2116.840,
3217.77759,1439.598,4296.34912,2116.840,
3217.86890,1439.598,4296.44092,2117.840,
3217.96045,1439.598,4296.53223,2117.840,
3218.05200,1440.598,4296.62402,2117.840,
3218.14355,1439.598,4296.71533,2118.840,
3218.23511,1438.598,4296.80713,2118.840,
3218.32666,1438.598,4296.89844,2119.840,
3218.41821,1439.598,4296.98975,2119.840,
3218.50977,1439.598,4297.08154,2118.840,
3218.60107,1439.598,4297.17285,2119.840,
3218.69263,1439.598,4297.26465,2120.840,
3218.78418,1440.598,4297.35596,2120.840,
3218.87573,1440.598,4297.44775,2120.840,
3218.96729,1440.598,4297.53906,2120.840,
3219.05884,1440.598,4297.63086,2121.840,
3219.15039,1441.598,4297.72217,2121.840,
3219.24194,1442.598,4297.81348,2121.840,
3219.33325,1442.598,4297.90527,2122.840,
3219.42480,1442.598,4297.99658,2121.840,
3219.51636,1443.598,4298.08838,2122.840,
3219.60791,1443.598,4298.17969,2122.840,
3219.69946,1444.598,4298.27148,2122.840,
3219.79102,1443.598,4298.36279,2122.840,
3219.88257,1444.598,4298.45410,2123.840,
3219.97388,1444.598,4298.54590,2123.840,
3220.06543,1445.598,4298.63721,2123.840,
3220.15698,1445.598,4298.72900,2124.840,
3220.24854,1446.598,4298.82031,2124.840,
3220.34009,1446.598,4298.91211,2125.840,
3220.43164,1446.598,4299.00342,2125.840,
3220.52319,1447.598,4299.09473,2125.840,
3220.61475,1448.598,4299.18652,2125.840,
3220.70605,1449.598,4299.27783,2126.840,
3220.79761,1450.598,4299.36963,2127.840,
3220.88916,1450.598,4299.46094,2127.840,
3220.98071,1451.598,4299.55273,2127.840,
3221.07227,1451.598,4299.64404,2127.840,
3221.16382,1452.598,4299.73584,2127.840,
3221.25537,1452.598,4299.82715,2128.840,
3221.34668,1452.598,4299.91846,2128.840,
3221.43823,1452.598,4300.01025,2128.840,
3221.52979,1453.598,4300.10156,2129.840,
3221.62134,1452.598,4300.19336,2129.840,
3221.71289,1452.598,4300.28467,2130.840,
3221.80444,1452.598,4300.37646,2129.840,
3221.89600,1452.598,4300.46777,2129.840,
3221.98755,1452.598,4300.55908,2130.840,
3222.07886,1451.598,4300.65088,2130.840,
3222.17041,1452.598,4300.74219,2130.840,
3222.26196,1452.598,4300.83398,2131.840,
3222.35352,1452.598,4300.92529,2131.840,
3222.44507,1452.598,4301.01709,2131.840,
3222.53662,1453.598,4301.10840,2131.840,
3222.62817,1453.598,4301.19971,2132.840,
3222.71973,1452.598,4301.29150,2132.840,
3222.81104,1453.598,4301.38281,2132.840,
3222.90259,1453.598,4301.47461,2132.840,
3222.99414,1453.598,4301.56592,2133.840,
3223.08569,1453.598,4301.65771,2134.840,
3223.17725,1453.598,4301.74902,2134.840,
3223.26880,1453.598,4301.84082,2134.840,
3223.36035,1454.598,4301.93213,2134.840,
3223.45166,1454.598,4302.02344,2134.840,
3223.54321,1454.598,4302.11523,2135.840,
3223.63477,1454.598,4302.20654,2135.840,
3223.72632,1454.598,4302.29834,2135.840,
3223.81787,1455.598,4302.38965,2135.840,
3223.90942,1455.598,4302.48145,2136.840,
3224.00098,1455.598,4302.57275,2136.840,
3224.09253,1456.598,4302.66406,2136.840,
3224.18384,1455.598,4302.75586,2137.840,
3224.27539,1456.598,4302.84717,2137.840,
3224.36694,1456.598,4302.93896,2138.840,
3224.45850,1456.598,4303.03027,2138.840,
3224.55005,1456.598,4303.12207,2138.840,
3224.64160,1457.598,4303.21338,2138.840,
3224.73315,1457.598,4303.30469,2139.840,
3224.82471,1457.598,4303.39648,2139.840,
3224.91602,1457.598,4303.48779,2139.840,
3225.00757,1458.598,4303.57959,2139.840,
3225.09912,1458.598,4303.67090,2140.840,
3225.19067,1458.598,4303.76270,2140.840,
3225.28223,1458.598,4303.85400,2140.840,
3225.37378,1459.598,4303.94580,2140.840,
3225.46533,1459.598,4304.03711,2141.840,
3225.55664,1459.598,4304.12842,2141.840,
3225.64819,1460.598,4304.22021,2142.840,
3225.73975,1460.598,4304.31152,2141.840,
3225.83130,1460.598,4304.40332,2142.840,
3225.92285,1460.598,4304.49463,2142.840,
3226.01440,1461.598,4304.58643,2143.840,
3226.10596,1461.598,4304.67773,2143.840,
3226.19751,1461.598,4304.76904,2144.840,
3226.28882,1461.598,4304.86084,2143.840,
3226.38037,1462.598,4304.95215,2144.840,
3226.47192,1462.598,4305.04395,2145.840,
3226.56348,1462.598,4305.13525,2144.840,
3226.65503,1462.598,4305.22705,2145.840,
3226.74658,1463.598,4305.31836,2145.840,
3226.83813,1463.598,4305.40967,2145.840,
3226.92944,1464.598,4305.50146,2146.840,
3227.02100,1463.598,4305.59277,2146.840,
3227.11255,1463.598,4305.68457,2146.840,
3227.20410,1463.598,4305.77588,2146.840,
3227.29565,1464.598,4305.86768,2146.840,
3227.38721,1464.598,4305.95898,2147.840,
3227.47876,1465.598,4306.05078,2148.840,
3227.57031,1464.598,4306.14209,2147.840,
3227.66162,1465.598,4306.23340,2147.840,
3227.75317,1465.598,4306.32520,2147.840,
3227.84473,1465.598,4306.41650,2147.840,
3227.93628,1465.598,4306.50830,2148.840,
3228.02783,1466.598,4306.59961,2148.840,
3228.11938,1466.598,4306.69141,2148.840,
3228.21094,1466.598,4306.78271,2149.840,
3228.30249,1467.598,4306.87402,2149.840,
3228.39380,1467.598,4306.96582,2149.840,
3228.48535,1467.598,4307.05713,2150.840,
3228.57690,1467.598,4307.14893,2149.840,
3228.66846,1468.598,4307.24023,2150.840,
3228.76001,1468.598,4307.33203,2151.840,
3228.85156,1468.598,4307.42334,2151.840,
3228.94312,1468.598,4307.51465,2152.840,
3229.03442,1469.598,4307.60645,2152.840,
3229.12598,1468.598,4307.69775,2153.840,
3229.21753,1469.598,4307.78955,2153.840,
3229.30908,1469.598,4307.88086,2153.840,
3229.40063,1469.598,4307.97266,2153.840,
3229.49219,1470.598,4308.06396,2154.840,
3229.58374,1470.598,4308.15576,2154.840,
3229.67529,1470.598,4308.24707,2154.840,
3229.76660,1471.598,4308.33838,2155.840,
3229.85815,1470.598,4308.43018,2155.840,
3229.94971,1471.598,4308.52148,2155.840,
3230.04126,1471.598,4308.61328,2155.840,
3230.13281,1471.598,4308.70459,2156.840,
3230.22437,1472.598,4308.79639,2156.840,
3230.31592,1472.598,4308.88770,2156.840,
3230.40747,1472.598,4308.97900,2157.840,
3230.49878,1472.598,4309.07080,2157.840,
3230.59033,1472.598,4309.16211,2157.840,
3230.68188,1473.598,4309.25391,2158.840,
3230.77344,1473.598,4309.34521,2157.840,
3230.86499,1473.598,4309.43701,2158.840,
3230.95654,1473.598,4309.52832,2158.840,
3231.04810,1473.598,4309.61963,2159.840,
3231.13940,1474.598,4309.71143,2159.840,
3231.23096,1475.598,4309.80273,2159.840,
3231.32251,1474.598,4309.89453,2160.840,
3231.41406,1475.598,4309.98584,2160.840,
3231.50562,1475.598,4310.07764,2160.840,
3231.59717,1475.598,4310.16895,2160.840,
3231.68872,1476.598,4310.26025,2160.840,
3231.78027,1475.598,4310.35205,2161.840,
3231.87158,1476.598,4310.44336,2162.840,
3231.96313,1476.598,4310.53516,2161.840,
3232.05469,1476.598,4310.62646,2162.840,
3232.14624,1476.598,4310.71826,2162.840,
3232.23779,1476.598,4310.80957,2162.840,
3232.32935,1477.598,4310.90137,2162.840,
3232.42090,1477.598,4310.99268,2163.840,
3232.51245,1477.598,4311.08398,2163.840,
3232.60376,1478.598,4311.17578,2163.840,
3232.69531,1478.598,4311.26709,2164.840,
3232.78687,1478.598,4311.35889,2164.840,
3232.87842,1479.598,4311.45020,2164.840,
3232.96997,1479.598,4311.54199,2164.840,
3233.06152,1479.598,4311.63330,2165.840,
3233.15308,1479.598,4311.72461,2165.840,
3233.24438,1479.598,4311.81641,2165.840,
3233.33594,1479.598,4311.90771,2166.840,
3233.42749,1480.598,4311.99951,2166.840,
3233.51904,1480.598,4312.09082,2166.840,
3233.61060,1480.598,4312.18262,2166.840,
3233.70215,1481.598,4312.27393,2167.840,
3233.79370,1481.598,4312.36523,2167.840,
3233.88525,1481.598,4312.45703,2167.840,
3233.97656,1481.598,4312.54834,2168.840,
3234.06812,1481.598,4312.64014,2168.840,
3234.15967,1483.598,4312.73145,2168.840,
3234.25122,1482.598,4312.82324,2169.840,
3234.34277,1483.598,4312.91455,2169.840,
3234.43433,1483.598,4313.00635,2169.840,
3234.52588,1483.598,4313.09766,2170.840,
3234.61719,1483.598,4313.18896,2170.840,
3234.70874,1483.598,4313.28076,2170.840,
3234.80029,1484.598,4313.37207,2171.840,
3234.89185,1483.598,4313.46387,2171.840,
3234.98340,1484.598,4313.55518,2171.840,
3235.07495,1484.598,4313.64697,2171.840,
3235.16650,1485.598,4313.73828,2172.840,
3235.25806,1485.598,4313.82959,2172.840,
3235.34937,1485.598,4313.92139,2173.840,
3235.44092,1485.598,4314.01270,2172.840,
3235.53247,1485.598,4314.10449,2173.840,
3235.62402,1486.598,4314.19580,2173.840,
3235.71558,1486.598,4314.28760,2173.840,
3235.80713,1486.598,4314.37891,2173.840,
3235.89868,1487.598,4314.47021,2174.840,
3235.99023,1487.598,4314.56201,2174.840,
3236.08154,1487.598,4314.65332,2175.840,
3236.17310,1488.598,4314.74512,2175.840,
3236.26465,1489.598,4314.83643,2176.840,
3236.35620,1489.598,4314.92822,2175.840,
3236.44775,1491.598,4315.01953,2176.840,
3236.53931,1491.598,4315.11133,2176.840,
3236.63086,1491.598,4315.20264,2176.840,
3236.72217,1491.598,4315.29395,2177.840,
3236.81372,1491.598,4315.38574,2177.840,
3236.90527,1491.598,4315.47705,2177.840,
3236.99683,1491.598,4315.56885,2177.840,
3237.08838,1492.598,4315.66016,2177.840,
3237.17993,1491.598,4315.75195,2178.840,
3237.27148,1492.598,4315.84326,2178.840,
3237.36304,1492.598,4315.93457,2178.840,
3237.45435,1492.598,4316.02637,2179.840,
3237.54590,1492.598,4316.11768,2179.840,
3237.63745,1492.598,4316.20947,2179.840,
3237.72900,1492.598,4316.30078,2180.840,
3237.82056,1492.598,4316.39258,2180.840,
3237.91211,1493.598,4316.48389,2180.840,
3238.00366,1493.598,4316.57520,2181.840,
3238.09521,1492.598,4316.66699,2181.840,
3238.18652,1492.598,4316.75830,2182.840,
3238.27808,1493.598,4316.85010,2182.840,
3238.36963,1493.598,4316.94141,2182.840,
3238.46118,1493.598,4317.03320,2182.840,
3238.55273,1494.598,4317.12451,2182.840,
3238.64429,1495.598,4317.21631,2183.840,
3238.73584,1496.598,4317.30762,2183.840,
3238.82715,1496.598,4317.39893,2183.840,
3238.91870,1497.598,4317.49072,2184.840,
3239.01025,1497.598,4317.58203,2184.840,
3239.10181,1498.598,4317.67383,2184.840,
3239.19336,1498.598,4317.76514,2185.840,
3239.28491,1498.598,4317.85693,2185.840,
3239.37646,1498.598,4317.94824,2185.840,
3239.46802,1498.598,4318.03955,2185.840,
3239.55933,1498.598,4318.13135,2186.840,
3239.65088,1498.598,4318.22266,2186.840,
3239.74243,1498.598,4318.31445,2186.840,
3239.83398,1499.598,4318.40576,2187.840,
3239.92554,1499.598,4318.49756,2187.840,
3240.01709,1499.598,4318.58887,2187.840,
3240.10864,1499.598,4318.68018,2187.840,
3240.19995,1498.598,4318.77197,2188.840,
3240.29150,1499.598,4318.86328,2188.840,
3240.38306,1499.598,4318.95508,2189.840,
3240.47461,1498.598,4319.04639,2189.840,
3240.56616,1499.598,4319.13818,2189.840,
3240.65771,1500.598,4319.22949,2189.840,
3240.74927,1499.598,4319.32129,2190.840,
3240.84082,1499.598,4319.41260,2190.840,
3240.93213,1500.598,4319.50391,2190.840,
3241.02368,1500.598,4319.59570,2190.840,
3241.11523,1500.598,4319.68701,2191.840,
3241.20679,1501.598,4319.77881,2191.840,
3241.29834,1501.598,4319.87012,2191.840,
3241.38989,1500.598,4319.96191,2192.840,
3241.48145,1502.598,4320.05322,2192.840,
3241.57300,1501.598,4320.14453,2192.840,
3241.66431,1502.598,4320.23633,2192.840,
3241.75586,1502.598,4320.32764,2193.840,
3241.84741,1502.598,4320.41943,2193.840,
3241.93896,1502.598,4320.51074,2193.840,
3242.03052,1502.598,4320.60254,2194.840,
3242.12207,1503.598,4320.69385,2194.840,
3242.21362,1503.598,4320.78516,2194.840,
3242.30493,1503.598,4320.87695,2194.840,
3242.39648,1504.598,4320.96826,2195.840,
3242.48804,1504.598,4321.06006,2195.840,
3242.57959,1504.598,4321.15137,2195.840,
3242.67114,1504.598,4321.24316,2196.840,
3242.76270,1505.598,4321.33447,2196.840,
3242.85425,1505.598,4321.42578,2197.840,
3242.94580,1505.598,4321.51758,2197.840,
3243.03711,1505.598,4321.60889,2197.840,
3243.12866,1505.598,4321.70068,2197.840,
3243.22021,1506.598,4321.79199,2197.840,
3243.31177,1505.598,4321.88379,2198.840,
3243.40332,1506.598,4321.97510,2198.840,
3243.49487,1505.598,4322.06689,2198.840,
3243.58643,1507.598,4322.15820,2199.840,
3243.67798,1507.598,4322.24951,2199.840,
3243.76929,1507.598,4322.34131,2199.840,
3243.86084,1507.598,4322.43262,2200.840,
3243.95239,1507.598,4322.52441,2200.840,
3244.04395,1508.598,4322.61572,2200.840,
3244.13550,1508.598,4322.70752,2201.840,
3244.22705,1508.598,4322.79883,2201.840,
3244.31860,1508.598,4322.89014,2201.840,
3244.40991,1509.598,4322.98193,2201.840,
3244.50146,1509.598,4323.07324,2201.840,
3244.59302,1510.598,4323.16504,2201.840,
3244.68457,1510.598,4323.25635,2202.840,
3244.77612,1510.598,4323.34814,2202.840,
3244.86768,1511.598,4323.43945,2202.840,
3244.95923,1511.598,4323.53076,2202.840,
3245.05078,1511.598,4323.62256,2203.840,
3245.14209,1511.598,4323.71387,2203.840,
3245.23364,1511.598,4323.80566,2204.840,
3245.32520,1511.598,4323.89697,2204.840,
3245.41675,1511.598,4323.98877,2205.840,
3245.50830,1511.598,4324.08008,2204.840,
3245.59985,1512.598,4324.17188,2205.840,
3245.69141,1512.598,4324.26318,2205.840,
3245.78271,1512.598,4324.35449,2205.840,
3245.87427,1513.598,4324.44629,2205.840,
3245.96582,1513.598,4324.53760,2206.840,
3246.05737,1513.598,4324.62939,2206.840,
3246.14893,1514.598,4324.72070,2206.840,
3246.24048,1513.598,4324.81250,2206.840,
3246.33203,1514.598,4324.90381,2207.840,
3246.42358,1514.598,4324.99512,2207.840,
3246.51489,1514.598,4325.08691,2207.840,
3246.60645,1515.598,4325.17822,2207.840,
3246.69800,1515.598,4325.27002,2207.840,
3246.78955,1515.598,4325.36133,2208.840,
3246.88110,1515.598,4325.45313,2208.840,
3246.97266,1515.598,4325.54443,2208.840,
3247.06421,1516.598,4325.63574,2209.840,
3247.15576,1516.598,4325.72754,2208.840,
3247.24707,1515.598,4325.81885,2209.840,
3247.33862,1517.598,4325.91064,2210.840,
3247.43018,1517.598,4326.00195,2210.840,
3247.52173,1516.598,4326.09375,2210.840,
3247.61328,1517.598,4326.18506,2210.840,
3247.70483,1517.598,4326.27686,2211.840,
3247.79639,1517.598,4326.36816,2211.840,
3247.88770,1518.598,4326.45947,2211.840,
3247.97925,1518.598,4326.55127,2212.840,
3248.07080,1518.598,4326.64258,2212.840,
3248.16235,1519.598,4326.73438,2212.840,
3248.25391,1519.598,4326.82568,2212.840,
3248.34546,1518.598,4326.91748,2213.840,
3248.43701,1519.598,4327.00879,2213.840,
3248.52856,1519.598,4327.10010,2214.840,
3248.61987,1520.598,4327.19189,2214.840,
3248.71143,1520.598,4327.28320,2214.840,
3248.80298,1521.598,4327.37500,2215.840,
3248.89453,1521.598,4327.46631,2215.840,
3248.98608,1521.598,4327.55811,2215.840,
3249.07764,1521.598,4327.64941,2215.840,
3249.16919,1521.598,4327.74072,2216.840,
3249.26074,1521.598,4327.83252,2216.840,
3249.35205,1522.598,4327.92383,2216.840,
3249.44360,1522.598,4328.01563,2217.840,
3249.53516,1522.598,4328.10693,2217.840,
3249.62671,1522.598,4328.19873,2217.840,
3249.71826,1523.598,4328.29004,2217.840,
3249.80981,1523.598,4328.38184,2218.840,
3249.90137,1523.598,4328.47314,2218.840,
3249.99268,1523.598,4328.56445,2218.840,
3250.08423,1523.598,4328.65625,2219.840,
3250.17578,1524.598,4328.74756,2219.840,
3250.26733,1524.598,4328.83936,2219.840,
3250.35889,1524.598,4328.93066,2219.840,
3250.45044,1525.598,4329.02246,2219.840,
3250.54199,1525.598,4329.11377,2219.840,
3250.63354,1525.598,4329.20508,2220.840,
3250.72485,1526.598,4329.29688,2220.840,
3250.81641,1525.598,4329.38818,2220.840,
3250.90796,1526.598,4329.47998,2222.840,
3250.99951,1525.598,4329.57129,2222.840,
3251.09106,1526.598,4329.66309,2222.840,
3251.18262,1527.598,4329.75439,2222.840,
3251.27417,1527.598,4329.84570,2223.840,
3251.36572,1527.598,4329.93750,2223.840,
3251.45703,1527.598,4330.02881,2223.840,
3251.54858,1527.598,4330.12061,2223.840,
3251.64014,1527.598,4330.21191,2224.840,
3251.73169,1528.598,4330.30371,2224.840,
3251.82324,1528.598,4330.39502,2224.840,
3251.91479,1528.598,4330.48682,2224.840,
3252.00635,1529.598,4330.57813,2225.840,
3252.09766,1529.598,4330.66943,2225.840,
3252.18921,1529.598,4330.76123,2225.840,
3252.28076,1529.598,4330.85254,2225.840,
3252.37231,1529.598,4330.94434,2226.840,
3252.46387,1530.598,4331.03564,2226.840,
3252.55542,1530.598,4331.12744,2226.840,
3252.64697,1530.598,4331.21875,2226.840,
3252.73853,1531.598,4331.31006,2226.840,
3252.82983,1531.598,4331.40186,2227.840,
3252.92139,1531.598,4331.49316,2227.840,
3253.01294,1531.598,4331.58496,2227.840,
3253.10449,1531.598,4331.67627,2228.840,
3253.19604,1532.598,4331.76807,2228.840,
3253.28760,1532.598,4331.85938,2229.840,
3253.37915,1533.598,4331.95068,2229.840,
3253.47046,1533.598,4332.04248,2229.840,
3253.56201,1533.598,4332.13379,2229.840,
3253.65356,1533.598,4332.22559,2230.840,
3253.74512,1533.598,4332.31689,2230.840,
3253.83667,1533.598,4332.40869,2231.840,
3253.92822,1534.598,4332.50000,2231.840,
3254.01978,1534.598,4332.59180,2231.840,
3254.11133,1533.598,4332.68311,2231.840,
3254.20264,1534.598,4332.77441,2231.840,
3254.29419,1533.598,4332.86621,2231.840,
3254.38574,1533.598,4332.95752,2232.840,
3254.47729,1533.598,4333.04932,2232.840,
3254.56885,1533.598,4333.14063,2232.840,
3254.66040,1533.598,4333.23242,2233.840,
3254.75195,1533.598,4333.32373,2233.840,
3254.84351,1533.598,4333.41504,2234.840,
3254.93481,1534.598,4333.50684,2233.840,
3255.02637,1534.598,4333.59814,2234.840,
3255.11792,1535.598,4333.68994,2234.840,
3255.20947,1535.598,4333.78125,2234.840,
3255.30103,1535.598,4333.87305,2235.840,
3255.39258,1536.598,4333.96436,2235.840,
3255.48413,1536.598,4334.05566,2235.840,
3255.57544,1537.598,4334.14746,2235.840,
3255.66699,1537.598,4334.23877,2236.840,
3255.75854,1537.598,4334.33057,2236.840,
3255.85010,1538.598,4334.42188,2236.840,
3255.94165,1539.598,4334.51367,2237.840,
3256.03320,1539.598,4334.60498,2237.840,
3256.12476,1540.598,4334.69629,2236.840,
3256.21631,1540.598,4334.78809,2237.840,
3256.30762,1540.598,4334.87939,2237.840,
3256.39917,1541.598,4334.97119,2238.840,
3256.49072,1541.598,4335.06250,2238.840,
3256.58228,1542.598,4335.15430,2238.840,
3256.67383,1543.598,4335.24561,2238.840,
3256.76538,1544.598,4335.33740,2240.840,
3256.85693,1545.598,4335.42871,2239.840,
3256.94849,1545.598,4335.52002,2240.840,
3257.03979,1546.598,4335.61182,2240.840,
3257.13135,1545.598,4335.70313,2241.840,
3257.22290,1546.598,4335.79492,2240.840,
3257.31445,1545.598,4335.88623,2241.840,
3257.40601,1546.598,4335.97803,2241.840,
3257.49756,1545.598,4336.06934,2241.840,
3257.58911,1546.598,4336.16064,2242.840,
3257.68042,1545.598,4336.25244,2242.840,
3257.77197,1546.598,4336.34375,2242.840,
3257.86353,1546.598,4336.43555,2242.840,
3257.95508,1546.598,4336.52686,2242.840,
3258.04663,1546.598,4336.61865,2243.840,
3258.13818,1546.598,4336.70996,2243.840,
3258.22974,1546.598,4336.80127,2244.840,
3258.32129,1546.598,4336.89307,2244.840,
3258.41260,1546.598,4336.98438,2244.840,
3258.50415,1546.598,4337.07617,2244.840,
3258.59570,1546.598,4337.16748,2245.840,
3258.68726,1546.598,4337.25928,2245.840,
3258.77881,1546.598,4337.35059,2245.840,
3258.87036,1547.598,4337.44238,2245.840,
3258.96191,1547.598,4337.53369,2245.840,
3259.05322,1548.598,4337.62500,2246.840,
3259.14478,1548.598,4337.71680,2246.840,
3259.23633,1548.598,4337.80811,2246.840,
3259.32788,1548.598,4337.89990,2247.840,
3259.41943,1548.598,4337.99121,2247.840,
3259.51099,1548.598,4338.08301,2247.840,
3259.60254,1549.598,4338.17432,2248.840,
3259.69409,1549.598,4338.26563,2249.840,
3259.78540,1549.598,4338.35742,2248.840,
3259.87695,1549.598,4338.44873,2249.840,
3259.96851,1550.598,4338.54053,2249.840,
3260.06006,1550.598,4338.63184,2249.840,
3260.15161,1550.598,4338.72363,2250.840,
3260.24316,1551.598,4338.81494,2250.840,
3260.33472,1550.598,4338.90625,2250.840,
3260.42627,1551.598,4338.99805,2250.840,
3260.51758,1552.598,4339.08936,2250.840,
3260.60913,1551.598,4339.18115,2250.840,
3260.70068,1552.598,4339.27246,2251.840,
3260.79224,1552.598,4339.36426,2250.840,
3260.88379,1552.598,4339.45557,2251.840,
3260.97534,1552.598,4339.54736,2251.840,
3261.06689,1552.598,4339.63867,2251.840,
3261.15820,1553.598,4339.72998,2253.840,
3261.24976,1553.598,4339.82178,2252.840,
3261.34131,1553.598,4339.91309,2253.840,
3261.43286,1554.598,4340.00488,2254.840,
3261.52441,1553.598,4340.09619,2253.840,
3261.61597,1554.598,4340.18799,2254.840,
3261.70752,1554.598,4340.27930,2254.840,
3261.79907,1555.598,4340.37061,2255.840,
3261.89038,1555.598,4340.46240,2255.840,
3261.98193,1555.598,4340.55371,2255.840,
3262.07349,1555.598,4340.64551,2255.840,
3262.16504,1555.598,4340.73682,2255.840,
3262.25659,1556.598,4340.82861,2255.840,
3262.34814,1556.598,4340.91992,2256.840,
3262.43970,1557.598,4341.01123,2256.840,
3262.53125,1556.598,4341.10303,2257.840,
3262.62256,1557.598,4341.19434,2257.840,
3262.71411,1557.598,4341.28613,2258.840,
3262.80566,1557.598,4341.37744,2258.840,
3262.89722,1557.598,4341.46924,2258.840,
3262.98877,1557.598,4341.56055,2258.840,
3263.08032,1558.598,4341.65234,2259.840,
3263.17188,1558.598,4341.74365,2259.840,
3263.26318,1558.598,4341.83496,2260.840,
3263.35474,1558.598,4341.92676,2260.840,
3263.44629,1559.598,4342.01807,2260.840,
3263.53784,1559.598,4342.10986,2260.840,
3263.62939,1559.598,4342.20117,2260.840,
3263.72095,1559.598,4342.29297,2261.840,
3263.81250,1559.598,4342.38428,2261.840,
3263.90405,1560.598,4342.47559,2261.840,
3263.99536,1560.598,4342.56738,2261.840,
3264.08691,1561.598,4342.65869,2262.840,
3264.17847,1561.598,4342.75049,2262.840,
3264.27002,1560.598,4342.84180,2262.840,
3264.36157,1561.598,4342.93359,2262.840,
3264.45313,1561.598,4343.02490,2263.840,
3264.54468,1561.598,4343.11621,2263.840,
3264.63599,1562.598,4343.20801,2263.840,
3264.72754,1562.598,4343.29932,2264.840,
3264.81909,1562.598,4343.39111,2264.840,
3264.91064,1563.598,4343.48242,2264.840,
3265.00220,1563.598,4343.57422,2265.840,
3265.09375,1563.598,4343.66553,2264.840,
3265.18530,1563.598,4343.75732,2265.840,
3265.27686,1563.598,4343.84863,2265.840,
3265.36816,1564.598,4343.93994,2265.840,
3265.45972,1564.598,4344.03174,2266.840,
3265.55127,1564.598,4344.12305,2267.840,
3265.64282,1564.598,4344.21484,2266.840,
3265.73438,1564.598,4344.30615,2267.840,
3265.82593,1564.598,4344.39795,2267.840,
3265.91748,1565.598,4344.48926,2267.840,
3266.00903,1565.598,4344.58057,2268.840,
3266.10034,1565.598,4344.67236,2268.840,
3266.19189,1566.598,4344.76367,2268.840,
3266.28345,1566.598,4344.85547,2268.840,
3266.37500,1567.598,4344.94678,2268.840,
3266.46655,1566.598,4345.03857,2269.840,
3266.55811,1567.598,4345.12988,2269.840,
3266.64966,1567.598,4345.22119,2269.840,
3266.74097,1567.598,4345.31299,2270.840,
3266.83252,1568.598,4345.40430,2270.840,
3266.92407,1568.598,4345.49609,2270.840,
3267.01563,1568.598,4345.58740,2271.840,
3267.10718,1568.598,4345.67920,2271.840,
3267.19873,1569.598,4345.77051,2271.840,
3267.29028,1569.598,4345.86182,2271.840,
3267.38184,1569.598,4345.95361,2271.840,
3267.47314,1570.598,4346.04492,2272.840,
3267.56470,1570.598,4346.13672,2272.840,
3267.65625,1570.598,4346.22803,2273.840,
3267.74780,1570.598,4346.31982,2273.840,
3267.83936,1571.598,4346.41113,2273.840,
3267.93091,1570.598,4346.50293,2273.840,
3268.02246,1571.598,4346.59424,2274.840,
3268.11401,1571.598,4346.68555,2274.840,
3268.20532,1571.598,4346.77734,2274.840,
3268.29688,1572.598,4346.86865,2275.840,
3268.38843,1572.598,4346.96045,2275.840,
3268.47998,1572.598,4347.05176,2276.840,
3268.57153,1572.598,4347.14355,2275.840,
3268.66309,1573.598,4347.23486,2276.840,
3268.75464,1573.598,4347.32617,2276.840,
3268.84595,1573.598,4347.41797,2276.840,
3268.93750,1573.598,4347.50928,2276.840,
3269.02905,1574.598,4347.60107,2277.840,
3269.12061,1574.598,4347.69238,2277.840,
3269.21216,1573.598,4347.78418,2278.840,
3269.30371,1575.598,4347.87549,2277.840,
3269.39526,1575.598,4347.96680,2278.840,
3269.48682,1575.598,4348.05859,2278.840,
3269.57813,1575.598,4348.14990,2278.840,
3269.66968,1575.598,4348.24170,2278.840,
3269.76123,1575.598,4348.33301,2279.840,
3269.85278,1576.598,4348.42480,2279.840,
3269.94434,1576.598,4348.51611,2280.840,
3270.03589,1576.598,4348.60791,2280.840,
3270.12744,1577.598,4348.69922,2280.840,
3270.21875,1577.598,4348.79053,2280.840,
3270.31030,1577.598,4348.88232,2280.840,
3270.40186,1577.598,4348.97363,2281.840,
3270.49341,1577.598,4349.06543,2281.840,
3270.58496,1577.598,4349.15674,2281.840,
3270.67651,1578.598,4349.24854,2282.840,
3270.76807,1579.598,4349.33984,2282.840,
3270.85962,1579.598,4349.43115,2282.840,
3270.95093,1579.598,4349.52295,2282.840,
3271.04248,1579.598,4349.61426,2283.840,
3271.13403,1579.598,4349.70605,2283.840,
3271.22559,1579.598,4349.79736,2283.840,
3271.31714,1580.598,4349.88916,2283.840,
3271.40869,1580.598,4349.98047,2284.840,
3271.50024,1580.598,4350.07178,2284.840,
3271.59180,1581.598,4350.16357,2284.840,
3271.68311,1581.598,4350.25488,2284.840,
3271.77466,1581.598,4350.34668,2285.840,
3271.86621,1581.598,4350.43799,2286.840,
3271.95776,1581.598,4350.52979,2286.840,
3272.04932,1581.598,4350.62109,2286.840,
3272.14087,1581.598,4350.71289,2286.840,
3272.23242,1583.598,4350.80420,2286.840,
3272.32373,1583.598,4350.89551,2287.840,
3272.41528,1582.598,4350.98730,2287.840,
3272.50684,1583.598,4351.07861,2287.840,
3272.59839,1583.598,4351.17041,2287.840,
3272.68994,1583.598,4351.26172,2288.840,
3272.78149,1584.598,4351.35352,2288.840,
3272.87305,1584.598,4351.44482,2289.840,
3272.96460,1584.598,4351.53613,2289.840,
3273.05591,1584.598,4351.62793,2289.840,
3273.14746,1585.598,4351.71924,2289.840,
3273.23901,1585.598,4351.81104,2289.840,
3273.33057,1585.598,4351.90234,2290.840,
3273.42212,1585.598,4351.99414,2290.840,
3273.51367,1586.598,4352.08545,2290.840,
3273.60522,1586.598,4352.17676,2290.840,
3273.69678,1587.598,4352.26855,2291.840,
3273.78809,1586.598,4352.35986,2291.840,
3273.87964,1587.598,4352.45166,2292.840,
3273.97119,1587.598,4352.54297,2292.840,
3274.06274,1588.598,4352.63477,2292.840,
3274.15430,1588.598,4352.72607,2292.840,
3274.24585,1587.598,4352.81787,2293.840,
3274.33740,1588.598,4352.90918,2293.840,
3274.42871,1588.598,4353.00049,2293.840,
3274.52026,1589.598,4353.09229,2294.840,
3274.61182,1588.598,4353.18359,2294.840,
3274.70337,1589.598,4353.27539,2294.840,
3274.79492,1590.598,4353.36670,2294.840,
3274.88647,1590.598,4353.45850,2294.840,
3274.97803,1591.598,4353.54980,2295.840,
3275.06958,1591.598,4353.64111,2295.840,
3275.16089,1593.598,4353.73291,2295.840,
3275.25244,1592.598,4353.82422,2295.840,
3275.34399,1592.598,4353.91602,2296.840,
3275.43555,1593.598,4354.00732,2297.840,
3275.52710,1592.598,4354.09912,2296.840,
3275.61865,1593.598,4354.19043,2297.840,
3275.71021,1593.598,4354.28174,2297.840,
3275.80176,1593.598,4354.37354,2298.840,
3275.89307,1593.598,4354.46484,2298.840,
3275.98462,1592.598,4354.55664,2298.840,
3276.07617,1592.598,4354.64795,2298.840,
3276.16772,1593.598,4354.73975,2299.840,
3276.25928,1593.598,4354.83105,2299.840,
3276.35083,1593.598,4354.92285,2299.840,
3276.44238,1594.598,4355.01416,2300.840,
3276.53369,1594.598,4355.10547,2299.840,
3276.62524,1594.598,4355.19727,2300.840,
3276.71680,1594.598,4355.28857,2299.840,
3276.80835,1595.598,4355.38037,2300.840,
3276.89990,1595.598,4355.47168,2300.840,
3276.99146,1595.598,4355.56348,2301.840,
3277.08301,1595.598,4355.65479,2301.840,
3277.17456,1595.598,4355.74609,2301.840,
3277.26587,1596.598,4355.83789,2302.840,
3277.35742,1596.598,4355.92920,2302.840,
3277.44897,1596.598,4356.02100,2303.840,
3277.54053,1596.598,4356.11230,2303.840,
3277.63208,1596.598,4356.20410,2304.840,
3277.72363,1597.598,4356.29541,2303.840,
3277.81519,1597.598,4356.38672,2304.840,
3277.90649,1597.598,4356.47852,2304.840,
3277.99805,1598.598,4356.56982,2304.840,
3278.08960,1599.598,4356.66162,2305.840,
3278.18115,1598.598,4356.75293,2305.840,
3278.27271,1599.598,4356.84473,2305.840,
3278.36426,1599.598,4356.93604,2305.840,
3278.45581,1599.598,4357.02783,2306.840,
3278.54736,1599.598,4357.11914,2306.840,
3278.63867,1599.598,4357.21045,2306.840,
3278.73022,1600.598,4357.30225,2307.840,
3278.82178,1600.598,4357.39355,2307.840,
3278.91333,1600.598,4357.48535,2307.840,
3279.00488,1601.598,4357.57666,2308.840,
3279.09644,1600.598,4357.66846,2308.840,
3279.18799,1601.598,4357.75977,2308.840,
3279.27954,1601.598,4357.85107,2308.840,
3279.37085,1602.598,4357.94287,2309.840,
3279.46240,1602.598,4358.03418,2308.840,
3279.55396,1603.598,4358.12598,2309.840,
3279.64551,1602.598,4358.21729,2309.840,
3279.73706,1602.598,4358.30908,2309.840,
3279.82861,1602.598,4358.40039,2310.840,
3279.92017,1603.598,4358.49170,2310.840,
3280.01147,1603.598,4358.58350,2310.840,
3280.10303,1604.598,4358.67480,2310.840,
3280.19458,1604.598,4358.76660,2311.840,
3280.28613,1604.598,4358.85791,2311.840,
3280.37769,1604.598,4358.94971,2311.840,
3280.46924,1605.598,4359.04102,2312.840,
3280.56079,1604.598,4359.13232,2312.840,
3280.65234,1605.598,4359.22412,2312.840,
3280.74365,1605.598,4359.31543,2312.840,
3280.83521,1605.598,4359.40723,2313.840,
3280.92676,1606.598,4359.49854,2313.840,
3281.01831,1606.598,4359.59033,2314.840,
3281.10986,1607.598,4359.68164,2314.840,
3281.20142,1607.598,4359.77344,2314.840,
3281.29297,1607.598,4359.86475,2315.840,
3281.38452,1607.598,4359.95605,2315.840,
3281.47583,1607.598,4360.04785,2315.840,
3281.56738,1607.598,4360.13916,2315.840,
3281.65894,1608.598,4360.23096,2316.840,
3281.75049,1608.598,4360.32227,2316.840,
3281.84204,1608.598,4360.41406,2316.840,
3281.93359,1609.598,4360.50537,2316.840,
3282.02515,1608.598,4360.59668,2316.840,
3282.11646,1608.598,4360.68848,2317.840,
3282.20801,1609.598,4360.77979,2317.840,
3282.29956,1609.598,4360.87158,2317.840,
3282.39111,1610.598,4360.96289,2317.840,
3282.48267,1610.598,4361.05469,2317.840,
3282.57422,1610.598,4361.14600,2318.840,
3282.66577,1610.598,4361.23730,2318.840,
3282.75732,1610.598,4361.32910,2318.840,
3282.84863,1611.598,4361.42041,2318.840,
3282.94019,1611.598,4361.51221,2319.840,
3283.03174,1611.598,4361.60352,2319.840,
3283.12329,1612.598,4361.69531,2320.840,
3283.21484,1612.598,4361.78662,2320.840,
3283.30640,1612.598,4361.87842,2319.840,
3283.39795,1612.598,4361.96973,2320.840,
3283.48926,1613.598,4362.06104,2320.840,
3283.58081,1612.598,4362.15283,2321.840,
3283.67236,1613.598,4362.24414,2321.840,
3283.76392,1613.598,4362.33594,2321.840,
3283.85547,1613.598,4362.42725,2322.840,
3283.94702,1614.598,4362.51904,2322.840,
3284.03857,1614.598,4362.61035,2322.840,
3284.13013,1614.598,4362.70166,2322.840,
3284.22144,1614.598,4362.79346,2323.840,
3284.31299,1615.598,4362.88477,2322.840,
3284.40454,1615.598,4362.97656,2323.840,
3284.49609,1615.598,4363.06787,2324.840,
3284.58765,1615.598,4363.15967,2324.840,
3284.67920,1616.598,4363.25098,2324.840,
3284.77075,1616.598,4363.34229,2324.840,
3284.86230,1616.598,4363.43408,2324.840,
3284.95361,1616.598,4363.52539,2325.840,
3285.04517,1617.598,4363.61719,2325.840,
3285.13672,1617.598,4363.70850,2325.840,
3285.22827,1618.598,4363.80029,2325.840,
3285.31982,1617.598,4363.89160,2326.840,
3285.41138,1618.598,4363.98340,2325.840,
3285.50293,1618.598,4364.07471,2326.840,
3285.59424,1618.598,4364.16602,2326.840,
3285.68579,1619.598,4364.25781,2327.840,
3285.77734,1618.598,4364.34912,2327.840,
3285.86890,1619.598,4364.44092,2328.840,
3285.96045,1619.598,4364.53223,2328.840,
3286.05200,1619.598,4364.62402,2328.840,
3286.14355,1620.598,4364.71533,2328.840,
3286.23511,1620.598,4364.80664,2328.840,
3286.32642,1620.598,4364.89844,2329.840,
3286.41797,1621.598,4364.98975,2329.840,
3286.50952,1621.598,4365.08154,2329.840,
3286.60107,1621.598,4365.17285,2330.840,
3286.69263,1622.598,4365.26465,2330.840,
3286.78418,1622.598,4365.35596,2330.840,
3286.87573,1623.598,4365.44727,2330.840,
3286.96729,1622.598,4365.53906,2330.840,
3287.05859,1623.598,4365.63037,2331.840,
3287.15015,1622.598,4365.72217,2331.840,
3287.24170,1623.598,4365.81348,2331.840,
3287.33325,1623.598,4365.90527,2332.840,
3287.42480,1624.598,4365.99658,2332.840,
3287.51636,1624.598,4366.08838,2333.840,
3287.60791,1624.598,4366.17969,2332.840,
3287.69922,1623.598,4366.27100,2333.840,
3287.79077,1624.598,4366.36279,2333.840,
3287.88232,1625.598,4366.45410,2334.840,
3287.97388,1625.598,4366.54590,2334.840,
3288.06543,1625.598,4366.63721,2334.840,
3288.15698,1625.598,4366.72900,2334.840,
3288.24854,1626.598,4366.82031,2335.840,
3288.34009,1627.598,4366.91162,2335.840,
3288.43140,1626.598,4367.00342,2335.840,
3288.52295,1626.598,4367.09473,2335.840,
3288.61450,1627.598,4367.18652,2336.840,
3288.70605,1627.598,4367.27783,2336.840,
3288.79761,1627.598,4367.36963,2336.840,
3288.88916,1628.598,4367.46094,2337.840,
3288.98071,1628.598,4367.55225,2337.840,
3289.07202,1628.598,4367.64404,2337.840,
3289.16357,1628.598,4367.73535,2338.840,
3289.25513,1628.598,4367.82715,2337.840,
3289.34668,1628.598,4367.91846,2338.840,
3289.43823,1628.598,4368.01025,2338.840,
3289.52979,1628.598,4368.10156,2338.840,
3289.62134,1629.598,4368.19336,2339.840,
3289.71289,1629.598,4368.28467,2339.840,
3289.80420,1630.598,4368.37598,2339.840,
3289.89575,1630.598,4368.46777,2340.840,
3289.98730,1630.598,4368.55908,2340.840,
3290.07886,1630.598,4368.65088,2340.840,
3290.17041,1631.598,4368.74219,2340.840,
3290.26196,1631.598,4368.83398,2340.840,
3290.35352,1632.598,4368.92529,2341.840,
3290.44507,1631.598,4369.01660,2341.840,
3290.53638,1632.598,4369.10840,2341.840,
3290.62793,1632.598,4369.19971,2342.840,
3290.71948,1632.598,4369.29150,2342.840,
3290.81104,1633.598,4369.38281,2342.840,
3290.90259,1633.598,4369.47461,2342.840,
3290.99414,1633.598,4369.56592,2343.840,
3291.08569,1634.598,4369.65723,2343.840,
3291.17700,1634.598,4369.74902,2344.840,
3291.26855,1635.598,4369.84033,2343.840,
3291.36011,1635.598,4369.93213,2344.840,
3291.45166,1636.598,4370.02344,2344.840,
3291.54321,1637.598,4370.11523,2344.840,
3291.63477,1637.598,4370.20654,2345.840,
3291.72632,1637.598,4370.29834,2345.840,
3291.81787,1638.598,4370.38965,2345.840,
3291.90918,1638.598,4370.48096,2346.840,
3292.00073,1638.598,4370.57275,2346.840,
3292.09229,1638.598,4370.66406,2346.840,
3292.18384,1638.598,4370.75586,2347.840,
3292.27539,1638.598,4370.84717,2346.840,
3292.36694,1638.598,4370.93896,2347.840,
3292.45850,1638.598,4371.03027,2347.840,
3292.55005,1638.598,4371.12158,2347.840,
3292.64136,1638.598,4371.21338,2347.840,
3292.73291,1638.598,4371.30469,2348.840,
3292.82446,1639.598,4371.39648,2348.840,
3292.91602,1638.598,4371.48779,2349.840,
3293.00757,1639.598,4371.57959,2348.840,
3293.09912,1639.598,4371.67090,2349.840,
3293.19067,1639.598,4371.76221,2349.840,
3293.28198,1639.598,4371.85400,2350.840,
3293.37354,1639.598,4371.94531,2350.840,
3293.46509,1639.598,4372.03711,2350.840,
3293.55664,1638.598,4372.12842,2350.840,
3293.64819,1639.598,4372.22021,2350.840,
3293.73975,1638.598,4372.31152,2351.840,
3293.83130,1638.598,4372.40283,2350.840,
3293.92285,1638.598,4372.49463,2351.840,
3294.01416,1637.598,4372.58594,2351.840,
3294.10571,1637.598,4372.67773,2352.840,
3294.19727,1639.598,4372.76904,2352.840,
3294.28882,1638.598,4372.86084,2352.840,
3294.38037,1639.598,4372.95215,2352.840,
3294.47192,1639.598,4373.04395,2353.840,
3294.56348,1639.598,4373.13525,2353.840,
3294.65503,1639.598,4373.22656,2353.840,
3294.74634,1640.598,4373.31836,2354.840,
3294.83789,1641.598,4373.40967,2355.840,
3294.92944,1642.598,4373.50146,2355.840,
3295.02100,1642.598,4373.59277,2355.840,
3295.11255,1642.598,4373.68457,2355.840,
3295.20410,1643.598,4373.77588,2355.840,
3295.29565,1643.598,4373.86719,2355.840,
3295.38696,1643.598,4373.95898,2356.840,
3295.47852,1644.598,4374.05029,2356.840,
3295.57007,1645.598,4374.14209,2357.840,
3295.66162,1645.598,4374.23340,2357.840,
3295.75317,1646.598,4374.32520,2357.840,
3295.84473,1645.598,4374.41650,2357.840,
3295.93628,1646.598,4374.50781,2357.840,
3296.02783,1646.598,4374.59961,2357.840,
3296.11914,1646.598,4374.69092,2358.840,
3296.21069,1646.598,4374.78271,2358.840,
3296.30225,1647.598,4374.87402,2359.840,
3296.39380,1648.598,4374.96582,2358.840,
3296.48535,1647.598,4375.05713,2359.840,
3296.57690,1648.598,4375.14893,2359.840,
3296.66846,1648.598,4375.24023,2359.840,
3296.75977,1649.598,4375.33154,2360.840,
3296.85132,1649.598,4375.42334,2360.840,
3296.94287,1649.598,4375.51465,2360.840,
3297.03442,1649.598,4375.60645,2360.840,
3297.12598,1650.598,4375.69775,2361.840,
3297.21753,1650.598,4375.78955,2361.840,
3297.30908,1650.598,4375.88086,2361.840,
3297.40063,1650.598,4375.97217,2361.840,
3297.49194,1650.598,4376.06396,2362.840,
3297.58350,1651.598,4376.15527,2363.840,
3297.67505,1651.598,4376.24707,2362.840,
3297.76660,1651.598,4376.33838,2363.840,
3297.85815,1652.598,4376.43018,2363.840,
3297.94971,1652.598,4376.52148,2364.840,
3298.04126,1652.598,4376.61279,2363.840,
3298.13281,1652.598,4376.70459,2364.840,
3298.22412,1652.598,4376.79590,2364.840,
3298.31567,1653.598,4376.88770,2364.840,
3298.40723,1653.598,4376.97900,2364.840,
3298.49878,1653.598,4377.07080,2364.840,
3298.59033,1654.598,4377.16211,2364.840,
3298.68188,1654.598,4377.25391,2365.840,
3298.77344,1654.598,4377.34521,2365.840,
3298.86475,1654.598,4377.43652,2365.840,
3298.95630,1655.598,4377.52832,2365.840,
3299.04785,1655.598,4377.61963,2366.840,
3299.13940,1655.598,4377.71143,2366.840,
3299.23096,1655.598,4377.80273,2367.840,
3299.32251,1656.598,4377.89453,2367.840,
3299.41406,1656.598,4377.98584,2368.840,
3299.50562,1656.598,4378.07715,2367.840,
3299.59692,1656.598,4378.16895,2368.840,
3299.68848,1656.598,4378.26025,2368.840,
3299.78003,1657.598,4378.35205,2369.840,
3299.87158,1657.598,4378.44336,2369.840,
3299.96313,1657.598,4378.53516,2369.840,
3300.05469,1658.598,4378.62646,2370.840,
3300.14624,1658.598,4378.71777,2370.840,
3300.23779,1658.598,4378.80957,2370.840,
3300.32910,1659.598,4378.90088,2370.840,
3300.42065,1658.598,4378.99268,2371.840,
3300.51221,1659.598,4379.08398,2371.840,
3300.60376,1659.598,4379.17578,2371.840,
3300.69531,1659.598,4379.26709,2372.840,
3300.78687,1659.598,4379.35889,2371.840,
3300.87842,1660.598,4379.45020,2371.840,
3300.96973,1660.598,4379.54150,2372.840,
3301.06128,1660.598,4379.63330,2372.840,
3301.15283,1660.598,4379.72461,2373.840,
3301.24438,1661.598,4379.81641,2373.840,
3301.33594,1661.598,4379.90771,2373.840,
3301.42749,1661.598,4379.99951,2373.840,
3301.51904,1661.598,4380.09082,2373.840,
3301.61060,1661.598,4380.18213,2374.840,
3301.70190,1662.598,4380.27393,2374.840,
3301.79346,1662.598,4380.36523,2374.840,
3301.88501,1662.598,4380.45703,2374.840,
3301.97656,1663.598,4380.54834,2375.840,
3302.06812,1663.598,4380.64014,2375.840,
3302.15967,1663.598,4380.73145,2376.840,
3302.25122,1663.598,4380.82275,2376.840,
3302.34253,1663.598,4380.91455,2376.840,
3302.43408,1663.598,4381.00586,2376.840,
3302.52563,1663.598,4381.09766,2377.840,
3302.61719,1664.598,4381.18896,2378.840,
3302.70874,1664.598,4381.28076,2377.840,
3302.80029,1664.598,4381.37207,2377.840,
3302.89185,1664.598,4381.46387,2378.840,
3302.98340,1665.598,4381.55518,2378.840,
3303.07471,1665.598,4381.64648,2378.840,
3303.16626,1665.598,4381.73828,2378.840,
3303.25781,1666.598,4381.82959,2379.840,
3303.34937,1666.598,4381.92139,2379.840,
3303.44092,1666.598,4382.01270,2379.840,
3303.53247,1667.598,4382.10449,2380.840,
3303.62402,1667.598,4382.19580,2380.840,
3303.71558,1667.598,4382.28711,2380.840,
3303.80688,1667.598,4382.37891,2381.840,
3303.89844,1667.598,4382.47021,2380.840,
3303.98999,1668.598,4382.56201,2381.840,
3304.08154,1668.598,4382.65332,2381.840,
3304.17310,1669.598,4382.74512,2381.840,
3304.26465,1669.598,4382.83643,2381.840,
3304.35620,1669.598,4382.92773,2382.840,
3304.44751,1670.598,4383.01953,2382.840,
3304.53906,1669.598,4383.11084,2383.840,
3304.63062,1670.598,4383.20264,2383.840,
3304.72217,1670.598,4383.29395,2383.840,
3304.81372,1671.598,4383.38574,2383.840,
3304.90527,1671.598,4383.47705,2383.840,
3304.99683,1671.598,4383.56836,2384.840,
3305.08838,1671.598,4383.66016,2385.840,
3305.17969,1671.598,4383.75146,2384.840,
3305.27124,1671.598,4383.84326,2385.840,
3305.36279,1672.598,4383.93457,2385.840,
3305.45435,1672.598,4384.02637,2385.840,
3305.54590,1672.598,4384.11768,2385.840,
3305.63745,1672.598,4384.20947,2386.840,
3305.72900,1673.598,4384.30078,2386.840,
3305.82056,1672.598,4384.39209,2386.840,
3305.91187,1673.598,4384.48389,2387.840,
3306.00342,1673.598,4384.57520,2387.840,
3306.09497,1674.598,4384.66699,2387.840,
3306.18652,1673.598,4384.75830,2387.840,
3306.27808,1674.598,4384.85010,2388.840,
3306.36963,1674.598,4384.94141,2388.840,
3306.46118,1674.598,4385.03271,2388.840,
3306.55249,1675.598,4385.12451,2389.840,
3306.64404,1675.598,4385.21582,2389.840,
3306.73560,1675.598,4385.30762,2389.840,
3306.82715,1676.598,4385.39893,2389.840,
3306.91870,1676.598,4385.49072,2389.840,
3307.01025,1676.598,4385.58203,2390.840,
3307.10181,1676.598,4385.67334,2390.840,
3307.19336,1676.598,4385.76514,2390.840,
3307.28467,1677.598,4385.85645,2391.840,
3307.37622,1677.598,4385.94824,2391.840,
3307.46777,1677.598,4386.03955,2391.840,
3307.55933,1678.598,4386.13135,2391.840,
3307.65088,1677.598,4386.22266,2392.840,
3307.74243,1678.598,4386.31445,2392.840,
3307.83398,1679.598,4386.40576,2392.840,
3307.92529,1679.598,4386.49707,2392.840,
3308.01685,1679.598,4386.58887,2393.840,
3308.10840,1679.598,4386.68018,2393.840,
3308.19995,1679.598,4386.77197,2393.840,
3308.29150,1679.598,4386.86328,2393.840,
3308.38306,1680.598,4386.95508,2394.840,
3308.47461,1680.598,4387.04639,2394.840,
3308.56616,1680.598,4387.13770,2395.840,
3308.65747,1680.598,4387.22949,2395.840,
3308.74902,1681.598,4387.32080,2395.840,
3308.84058,1682.598,4387.41260,2395.840,
3308.93213,1681.598,4387.50391,2396.840,
3309.02368,1682.598,4387.59570,2395.840,
3309.11523,1682.598,4387.68701,2396.840,
3309.20679,1682.598,4387.77832,2396.840,
3309.29834,1682.598,4387.87012,2397.840,
3309.38965,1683.598,4387.96143,2397.840,
3309.48120,1683.598,4388.05322,2397.840,
3309.57275,1683.598,4388.14453,2398.840,
3309.66431,1683.598,4388.23633,2398.840,
3309.75586,1683.598,4388.32764,2398.840,
3309.84741,1683.598,4388.41943,2398.840,
3309.93896,1683.598,4388.51074,2398.840,
3310.03027,1682.598,4388.60205,2399.840,
3310.12183,1682.598,4388.69385,2399.840,
3310.21338,1682.598,4388.78516,2399.840,
3310.30493,1683.598,4388.87695,2399.840,
3310.39648,1682.598,4388.96826,2400.840,
3310.48804,1682.598,4389.06006,2399.840,
3310.57959,1683.598,4389.15137,2400.840,
3310.67114,1683.598,4389.24268,2400.840,
3310.76245,1683.598,4389.33447,2401.840,
3310.85400,1684.598,4389.42578,2400.840,
3310.94556,1684.598,4389.51758,2401.840,
3311.03711,1685.598,4389.60889,2401.840,
3311.12866,1686.598,4389.70068,2402.840,
3311.22021,1686.598,4389.79199,2402.840,
3311.31177,1686.598,4389.88330,2402.840,
3311.40332,1687.598,4389.97510,2402.840,
3311.49463,1687.598,4390.06641,2403.840,
3311.58618,1687.598,4390.15820,2403.840,
3311.67773,1689.598,4390.24951,2403.840,
3311.76929,1689.598,4390.34131,2403.840,
3311.86084,1689.598,4390.43262,2403.840,
3311.95239,1689.598,4390.52441,2404.840,
3312.04395,1690.598,4390.61572,2404.840,
3312.13525,1690.598,4390.70703,2404.840,
3312.22681,1690.598,4390.79883,2405.840,
3312.31836,1692.598,4390.89014,2405.840,
3312.40991,1692.598,4390.98193,2406.840,
3312.50146,1693.598,4391.07324,2406.840,
3312.59302,1693.598,4391.16504,2405.840,
3312.68457,1694.598,4391.25635,2406.840,
3312.77612,1694.598,4391.34766,2407.840,
3312.86743,1695.598,4391.43945,2406.840,
3312.95898,1695.598,4391.53076,2407.840,
3313.05054,1695.598,4391.62256,2407.840,
3313.14209,1695.598,4391.71387,2407.840,
3313.23364,1696.598,4391.80566,2407.840,
3313.32520,1695.598,4391.89697,2408.840,
3313.41675,1696.598,4391.98828,2408.840,
3313.50830,1696.598,4392.08008,2408.840,
3313.59961,1695.598,4392.17139,2409.840,
3313.69116,1696.598,4392.26318,2409.840,
3313.78271,1696.598,4392.35449,2409.840,
3313.87427,1696.598,4392.44629,2410.840,
3313.96582,1696.598,4392.53760,2410.840,
3314.05737,1696.598,4392.62939,2409.840,
3314.14893,1696.598,4392.72070,2410.840,
3314.24023,1696.598,4392.81201,2411.840,
3314.33179,1696.598,4392.90381,2411.840,
3314.42334,1696.598,4392.99512,2411.840,
3314.51489,1696.598,4393.08691,2412.840,
3314.60645,1696.598,4393.17822,2411.840,
3314.69800,1697.598,4393.27002,2412.840,
3314.78955,1697.598,4393.36133,2412.840,
3314.88110,1697.598,4393.45264,2412.840,
3314.97241,1697.598,4393.54443,2412.840,
3315.06396,1698.598,4393.63574,2413.840,
3315.15552,1697.598,4393.72754,2413.840,
3315.24707,1698.598,4393.81885,2413.840,
3315.33862,1698.598,4393.91064,2414.840,
3315.43018,1699.598,4394.00195,2415.840,
3315.52173,1699.598,4394.09326,2414.840,
3315.61304,1699.598,4394.18506,2414.840,
3315.70459,1699.598,4394.27637,2415.840,
3315.79614,1700.598,4394.36816,2415.840,
3315.88770,1700.598,4394.45947,2415.840,
3315.97925,1700.598,4394.55127,2415.840,
3316.07080,1701.598,4394.64258,2416.840,
3316.16235,1702.598,4394.73438,2416.840,
3316.25391,1701.598,4394.82568,2417.840,
3316.34521,1702.598,4394.91699,2417.840,
3316.43677,1702.598,4395.00879,2417.840,
3316.52832,1702.598,4395.10010,2417.840,
3316.61987,1702.598,4395.19189,2418.840,
3316.71143,1702.598,4395.28320,2418.840,
3316.80298,1703.598,4395.37500,2419.840,
3316.89453,1703.598,4395.46631,2419.840,
3316.98608,1703.598,4395.55762,2419.840,
3317.07739,1704.598,4395.64941,2419.840,
3317.16895,1703.598,4395.74072,2419.840,
3317.26050,1704.598,4395.83252,2419.840,
3317.35205,1704.598,4395.92383,2419.840,
3317.44360,1704.598,4396.01563,2419.840,
3317.53516,1705.598,4396.10693,2420.840,
3317.62671,1706.598,4396.19824,2420.840,
3317.71802,1705.598,4396.29004,2421.840,
3317.80957,1706.598,4396.38135,2421.840,
3317.90112,1706.598,4396.47314,2421.840,
3317.99268,1706.598,4396.56445,2421.840,
3318.08423,1706.598,4396.65625,2422.840,
3318.17578,1706.598,4396.74756,2422.840,
3318.26733,1706.598,4396.83887,2423.840,
3318.35889,1707.598,4396.93066,2422.840,
3318.45020,1707.598,4397.02197,2423.840,
3318.54175,1707.598,4397.11377,2423.840,
3318.63330,1708.598,4397.20508,2423.840,
3318.72485,1708.598,4397.29688,2424.840,
3318.81641,1708.598,4397.38818,2423.840,
3318.90796,1709.598,4397.47998,2424.840,
3318.99951,1709.598,4397.57129,2424.840,
3319.09106,1709.598,4397.66260,2424.840,
3319.18237,1709.598,4397.75439,2424.840,
3319.27393,1710.598,4397.84570,2424.840,
3319.36548,1710.598,4397.93750,2425.840,
3319.45703,1710.598,4398.02881,2425.840,
3319.54858,1710.598,4398.12061,2426.840,
3319.64014,1710.598,4398.21191,2425.840,
3319.73169,1711.598,4398.30322,2427.840,
3319.82300,1711.598,4398.39502,2426.840,
3319.91455,1711.598,4398.48633,2426.840,
3320.00610,1711.598,4398.57813,2427.840,
3320.09766,1712.598,4398.66943,2427.840,
3320.18921,1712.598,4398.76123,2427.840,
3320.28076,1712.598,4398.85254,2427.840,
3320.37231,1712.598,4398.94385,2428.840,
3320.46387,1713.598,4399.03564,2428.840,
3320.55518,1713.598,4399.12695,2428.840,
3320.64673,1713.598,4399.21875,2429.840,
3320.73828,1713.598,4399.31006,2429.840,
3320.82983,1714.598,4399.40186,2429.840,
3320.92139,1714.598,4399.49316,2429.840,
3321.01294,1714.598,4399.58496,2429.840,
3321.10449,1714.598,4399.67627,2430.840,
3321.19580,1715.598,4399.76758,2430.840,
3321.28735,1715.598,4399.85938,2430.840,
3321.37891,1715.598,4399.95068,2430.840,
3321.47046,1715.598,4400.04248,2430.840,
3321.56201,1715.598,4400.13379,2431.840,
3321.65356,1716.598,4400.22559,2431.840,
3321.74512,1716.598,4400.31689,2431.840,
3321.83667,1716.598,4400.40820,2431.840,
3321.92798,1717.598,4400.50000,2432.840,
3322.01953,1718.598,4400.59131,2432.840,
3322.11108,1717.598,4400.68311,2432.840,
3322.20264,1717.598,4400.77441,2432.840,
3322.29419,1718.598,4400.86621,2433.840,
3322.38574,1718.598,4400.95752,2433.840,
3322.47729,1718.598,4401.04883,2433.840,
3322.56885,1719.598,4401.14063,2434.840,
3322.66016,1718.598,4401.23193,2434.840,
3322.75171,1719.598,4401.32373,2434.840,
3322.84326,1719.598,4401.41504,2435.840,
3322.93481,1719.598,4401.50684,2435.840,
3323.02637,1719.598,4401.59814,2435.840,
3323.11792,1720.598,4401.68994,2435.840,
3323.20947,1720.598,4401.78125,2436.840,
3323.30078,1720.598,4401.87256,2436.840,
3323.39233,1720.598,4401.96436,2436.840,
3323.48389,1722.598,4402.05566,2437.840,
3323.57544,1721.598,4402.14746,2436.840,
3323.66699,1722.598,4402.23877,2436.840,
3323.75854,1722.598,4402.33057,2437.840,
3323.85010,1722.598,4402.42188,2437.840,
3323.94165,1722.598,4402.51318,2437.840,
3324.03296,1723.598,4402.60498,2438.840,
3324.12451,1722.598,4402.69629,2439.840,
3324.21606,1723.598,4402.78809,2439.840,
3324.30762,1723.598,4402.87939,2438.840,
3324.39917,1723.598,4402.97119,2439.840,
3324.49072,1723.598,4403.06250,2439.840,
3324.58228,1724.598,4403.15381,2439.840,
3324.67383,1724.598,4403.24561,2440.840,
3324.76514,1724.598,4403.33691,2440.840,
3324.85669,1725.598,4403.42871,2439.840,
3324.94824,1725.598,4403.52002,2440.840,
3325.03979,1726.598,4403.61182,2441.840,
3325.13135,1725.598,4403.70313,2440.840,
3325.22290,1726.598,4403.79492,2441.840,
3325.31445,1726.598,4403.88623,2441.840,
3325.40576,1727.598,4403.97754,2441.840,
3325.49731,1727.598,4404.06934,2442.840,
3325.58887,1727.598,4404.16064,2442.840,
3325.68042,1727.598,4404.25244,2442.840,
3325.77197,1727.598,4404.34375,2442.840,
3325.86353,1727.598,4404.43555,2443.840,
3325.95508,1728.598,4404.52686,2443.840,
3326.04663,1728.598,4404.61816,2443.840,
3326.13794,1728.598,4404.70996,2443.840,
3326.22949,1728.598,4404.80127,2444.840,
3326.32104,1729.598,4404.89307,2444.840,
3326.41260,1730.598,4404.98438,2445.840,
3326.50415,1729.598,4405.07617,2444.840,
3326.59570,1729.598,4405.16748,2445.840,
3326.68726,1730.598,4405.25879,2445.840,
3326.77856,1730.598,4405.35059,2445.840,
3326.87012,1730.598,4405.44189,2445.840,
3326.96167,1730.598,4405.53369,2446.840,
3327.05322,1731.598,4405.62500,2447.840,
3327.14478,1731.598,4405.71680,2446.840,
3327.23633,1731.598,4405.80811,2446.840,
3327.32788,1731.598,4405.89990,2447.840,
3327.41943,1731.598,4405.99121,2447.840,
3327.51074,1731.598,4406.08252,2447.840,
3327.60229,1732.598,4406.17432,2448.840,
3327.69385,1732.598,4406.26563,2448.840,
3327.78540,1732.598,4406.35742,2448.840,
3327.87695,1733.598,4406.44873,2449.840,
3327.96851,1733.598,4406.54053,2449.840,
3328.06006,1733.598,4406.63184,2449.840,
3328.15161,1733.598,4406.72314,2449.840,
3328.24292,1734.598,4406.81494,2449.840,
3328.33447,1734.598,4406.90625,2449.840,
3328.42603,1735.598,4406.99805,2450.840,
3328.51758,1735.598,4407.08936,2451.840,
3328.60913,1735.598,4407.18115,2451.840,
3328.70068,1736.598,4407.27246,2451.840,
3328.79224,1736.598,4407.36377,2451.840,
3328.88354,1737.598,4407.45557,2451.840,
3328.97510,1737.598,4407.54688,2452.840,
3329.06665,1738.598,4407.63867,2452.840,
3329.15820,1739.598,4407.72998,2452.840,
3329.24976,1739.598,4407.82178,2452.840,
3329.34131,1740.598,4407.91309,2453.840,
3329.43286,1740.598,4408.00488,2453.840,
3329.52441,1740.598,4408.09619,2453.840,
3329.61572,1740.598,4408.18750,2453.840,
3329.70728,1741.598,4408.27930,2453.840,
3329.79883,1740.598,4408.37061,2453.840,
3329.89038,1740.598,4408.46240,2453.840,
3329.98193,1741.598,4408.55371,2455.840,
3330.07349,1740.598,4408.64551,2454.840,
3330.16504,1740.598,4408.73682,2454.840,
3330.25659,1740.598,4408.82813,2454.840,
3330.34790,1741.598,4408.91992,2455.840,
3330.43945,1741.598,4409.01123,2454.840,
3330.53101,1740.598,4409.10303,2455.840,
3330.62256,1741.598,4409.19434,2455.840,
3330.71411,1741.598,4409.28613,2456.840,
3330.80566,1741.598,4409.37744,2457.840,
3330.89722,1741.598,4409.46875,2457.840,
3330.98853,1741.598,4409.56055,2456.840,
3331.08008,1741.598,4409.65186,2457.840,
3331.17163,1740.598,4409.74365,2457.840,
3331.26318,1740.598,4409.83496,2457.840,
3331.35474,1740.598,4409.92676,2457.840,
3331.44629,1740.598,4410.01807,2459.840,
3331.53784,1739.598,4410.10938,2458.840,
3331.62939,1739.598,4410.20117,2458.840,
3331.72070,1739.598,4410.29248,2458.840,
3331.81226,1740.598,4410.38428,2459.840,
3331.90381,1740.598,4410.47559,2458.840,
3331.99536,1741.598,4410.56738,2459.840,
3332.08691,1741.598,4410.65869,2459.840,
3332.17847,1741.598,4410.75049,2460.840,
3332.27002,1742.598,4410.84180,2460.840,
3332.36157,1742.598,4410.93311,2460.840,
3332.45288,1743.598,4411.02490,2460.840,
3332.54443,1743.598,4411.11621,2461.840,
3332.63599,1744.598,4411.20801,2461.840,
3332.72754,1744.598,4411.29932,2461.840,
3332.81909,1745.598,4411.39111,2461.840,
3332.91064,1746.598,4411.48242,2463.840,
3333.00220,1746.598,4411.57373,2463.840,
3333.09351,1746.598,4411.66553,2463.840,
3333.18506,1747.598,4411.75684,2464.840,
3333.27661,1747.598,4411.84863,2464.840,
3333.36816,1747.598,4411.93994,2465.840,
3333.45972,1748.598,4412.03174,2464.840,
3333.55127,1748.598,4412.12305,2465.840,
3333.64282,1748.598,4412.21436,2465.840,
3333.73438,1749.598,4412.30615,2465.840,
3333.82568,1748.598,4412.39746,2465.840,
3333.91724,1749.598,4412.48926,2466.840,
3334.00879,1750.598,4412.58057,2465.840,
3334.10034,1749.598,4412.67236,2465.840,
3334.19189,1750.598,4412.76367,2465.840,
3334.28345,1750.598,4412.85547,2466.840,
3334.37500,1750.598,4412.94678,2467.840,
3334.46631,1751.598,4413.03809,2466.840,
3334.55786,1751.598,4413.12988,2467.840,
3334.64941,1751.598,4413.22119,2466.840,
3334.74097,1751.598,4413.31299,2467.840,
3334.83252,1752.598,4413.40430,2468.840,
3334.92407,1752.598,4413.49609,2468.840,
3335.01563,1752.598,4413.58740,2468.840,
3335.10718,1753.598,4413.67871,2468.840,
3335.19849,1754.598,4413.77051,2468.840,
3335.29004,1753.598,4413.86182,2468.840,
3335.38159,1753.598,4413.95361,2469.840,
3335.47314,1754.598,4414.04492,2469.840,
3335.56470,1755.598,4414.13672,2469.840,
3335.65625,1754.598,4414.22803,2470.840,
3335.74780,1755.598,4414.31934,2470.840,
3335.83936,1755.598,4414.41113,2471.840,
3335.93066,1755.598,4414.50244,2470.840,
3336.02222,1755.598,4414.59424,2470.840,
3336.11377,1755.598,4414.68555,2471.840,
3336.20532,1755.598,4414.77734,2471.840,
3336.29688,1755.598,4414.86865,2471.840,
3336.38843,1756.598,4414.96045,2471.840,
3336.47998,1756.598,4415.05176,2471.840,
3336.57129,1756.598,4415.14307,2472.840,
3336.66284,1757.598,4415.23486,2472.840,
3336.75439,1757.598,4415.32617,2472.840,
3336.84595,1757.598,4415.41797,2473.840,
3336.93750,1757.598,4415.50928,2473.840,
3337.02905,1758.598,4415.60107,2473.840,
3337.12061,1758.598,4415.69238,2473.840,
3337.21216,1758.598,4415.78369,2474.840,
3337.30347,1758.598,4415.87549,2474.840,
3337.39502,1759.598,4415.96680,2475.840,
3337.48657,1759.598,4416.05859,2475.840,
3337.57813,1760.598,4416.14990,2475.840,
3337.66968,1760.598,4416.24170,2475.840,
3337.76123,1759.598,4416.33301,2475.840,
3337.85278,1760.598,4416.42432,2476.840,
3337.94434,1761.598,4416.51611,2475.840,
3338.03564,1761.598,4416.60742,2476.840,
3338.12720,1761.598,4416.69922,2477.840,
3338.21875,1761.598,4416.79053,2477.840,
3338.31030,1762.598,4416.88232,2477.840,
3338.40186,1762.598,4416.97363,2477.840,
3338.49341,1762.598,4417.06543,2477.840,
3338.58496,1762.598,4417.15674,2477.840,
3338.67627,1762.598,4417.24805,2477.840,
3338.76782,1762.598,4417.33984,2478.840,
3338.85938,1763.598,4417.43115,2478.840,
3338.95093,1763.598,4417.52295,2479.840,
3339.04248,1763.598,4417.61426,2479.840,
3339.13403,1764.598,4417.70605,2479.840,
3339.22559,1764.598,4417.79736,2479.840,
3339.31714,1765.598,4417.88867,2479.840,
3339.40845,1765.598,4417.98047,2479.840,
3339.50000,1765.598,4418.07178,2480.840,
3339.59155,1765.598,4418.16357,2479.840,
3339.68311,1765.598,4418.25488,2480.840,
3339.77466,1766.598,4418.34668,2480.840,
3339.86621,1766.598,4418.43799,2481.840,
3339.95776,1766.598,4418.52930,2481.840,
3340.04907,1766.598,4418.62109,2481.840,
3340.14063,1767.598,4418.71240,2481.840,
3340.23218,1767.598,4418.80420,2482.840,
3340.32373,1767.598,4418.89551,2481.840,
3340.41528,1767.598,4418.98730,2482.840,
3340.50684,1767.598,4419.07861,2483.840,
3340.59839,1767.598,4419.17041,2482.840,
3340.68994,1768.598,4419.26172,2483.840,
3340.78125,1768.598,4419.35303,2483.840,
3340.87280,1769.598,4419.44482,2483.840,
3340.96436,1769.598,4419.53613,2483.840,
3341.05591,1770.598,4419.62793,2483.840,
3341.14746,1769.598,4419.71924,2484.840,
3341.23901,1770.598,4419.81104,2484.840,
3341.33057,1769.598,4419.90234,2485.840,
3341.42212,1770.598,4419.99365,2485.840,
3341.51343,1770.598,4420.08545,2485.840,
3341.60498,1770.598,4420.17676,2485.840,
3341.69653,1771.598,4420.26855,2486.840,
3341.78809,1771.598,4420.35986,2485.840,
3341.87964,1771.598,4420.45166,2486.840,
3341.97119,1771.598,4420.54297,2486.840,
3342.06274,1771.598,4420.63428,2486.840,
3342.15405,1771.598,4420.72607,2487.840,
3342.24561,1771.598,4420.81738,2487.840,
3342.33716,1773.598,4420.90918,2487.840,
3342.42871,1772.598,4421.00049,2487.840,
3342.52026,1773.598,4421.09229,2488.840,
3342.61182,1773.598,4421.18359,2488.840,
3342.70337,1773.598,4421.27490,2488.840,
3342.79492,1773.598,4421.36670,2488.840,
3342.88623,1774.598,4421.45801,2488.840,
3342.97778,1774.598,4421.54980,2488.840,
3343.06934,1774.598,4421.64111,2489.840,
3343.16089,1774.598,4421.73291,2490.840,
3343.25244,1775.598,4421.82422,2490.840,
3343.34399,1775.598,4421.91602,2490.840,
3343.43555,1775.598,4422.00732,2490.840,
3343.52710,1776.598,4422.09863,2490.840,
3343.61841,1776.598,4422.19043,2490.840,
3343.70996,1776.598,4422.28174,2491.840,
3343.80151,1777.598,4422.37354,2491.840,
3343.89307,1777.598,4422.46484,2492.840,
3343.98462,1777.598,4422.55664,2491.840,
3344.07617,1777.598,4422.64795,2492.840,
3344.16772,1777.598,4422.73926,2492.840,
3344.25903,1777.598,4422.83105,2492.840,
3344.35059,1778.598,4422.92236,2493.840,
3344.44214,1778.598,4423.01416,2492.840,
3344.53369,1778.598,4423.10547,2493.840,
3344.62524,1778.598,4423.19727,2494.840,
3344.71680,1779.598,4423.28857,2493.840,
3344.80835,1779.598,4423.37988,2494.840,
3344.89990,1779.598,4423.47168,2494.840,
3344.99121,1779.598,4423.56299,2494.840,
3345.08276,1780.598,4423.65479,2494.840,
3345.17432,1780.598,4423.74609,2495.840,
3345.26587,1780.598,4423.83789,2495.840,
3345.35742,1781.598,4423.92920,2495.840,
3345.44897,1781.598,4424.02100,2495.840,
3345.54053,1781.598,4424.11230,2495.840,
3345.63184,1781.598,4424.20361,2495.840,
3345.72339,1781.598,4424.29541,2496.840,
3345.81494,1782.598,4424.38672,2496.840,
3345.90649,1782.598,4424.47852,2497.840,
3345.99805,1782.598,4424.56982,2497.840,
3346.08960,1782.598,4424.66162,2498.840,
3346.18115,1783.598,4424.75293,2497.840,
3346.27271,1783.598,4424.84424,2497.840,
3346.36401,1783.598,4424.93604,2498.840,
3346.45557,1783.598,4425.02734,2498.840,
3346.54712,1784.598,4425.11914,2498.840,
3346.63867,1784.598,4425.21045,2498.840,
3346.73022,1784.598,4425.30225,2499.840,
3346.82178,1784.598,4425.39355,2499.840,
3346.91333,1785.598,4425.48486,2499.840,
3347.00488,1785.598,4425.57666,2499.840,
3347.09619,1785.598,4425.66797,2499.840,
3347.18774,1785.598,4425.75977,2500.840,
3347.27930,1786.598,4425.85107,2500.840,
3347.37085,1786.598,4425.94287,2500.840,
3347.46240,1786.598,4426.03418,2500.840,
3347.55396,1786.598,4426.12598,2501.840,
3347.64551,1786.598,4426.21729,2501.840,
3347.73682,1786.598,4426.30859,2501.840,
3347.82837,1787.598,4426.40039,2501.840,
3347.91992,1788.598,4426.49170,2501.840,
3348.01147,1788.598,4426.58350,2502.840,
3348.10303,1788.598,4426.67480,2502.840,
3348.19458,1787.598,4426.76660,2503.840,
3348.28613,1788.598,4426.85791,2502.840,
3348.37769,1788.598,4426.94922,2503.840,
3348.46899,1788.598,4427.04102,2503.840,
3348.56055,1788.598,4427.13232,2503.840,
3348.65210,1788.598,4427.22412,2503.840,
3348.74365,1788.598,4427.31543,2504.840,
3348.83521,1788.598,4427.40723,2504.840,
3348.92676,1789.598,4427.49854,2504.840,
3349.01831,1789.598,4427.58984,2505.840,
3349.10986,1790.598,4427.68164,2505.840,
3349.20117,1790.598,4427.77295,2505.840,
3349.29272,1791.598,4427.86475,2505.840,
3349.38428,1791.598,4427.95605,2505.840,
3349.47583,1791.598,4428.04785,2505.840,
3349.56738,1791.598,4428.13916,2506.840,
3349.65894,1792.598,4428.23096,2506.840,
3349.75049,1792.598,4428.32227,2507.840,
3349.84180,1793.598,4428.41357,2506.840,
3349.93335,1793.598,4428.50537,2507.840,
3350.02490,1793.598,4428.59668,2507.840,
3350.11646,1793.598,4428.68848,2507.840,
3350.20801,1794.598,4428.77979,2508.840,
3350.29956,1794.598,4428.87158,2508.840,
3350.39111,1794.598,4428.96289,2508.840,
3350.48267,1794.598,4429.05420,2509.840,
3350.57397,1795.598,4429.14600,2510.840,
3350.66553,1795.598,4429.23730,2510.840,
3350.75708,1796.598,4429.32910,2511.840,
3350.84863,1796.598,4429.42041,2511.840,
3350.94019,1797.598,4429.51221,2512.840,
3351.03174,1797.598,4429.60352,2512.840,
3351.12329,1798.598,4429.69482,2512.840,
3351.21484,1798.598,4429.78662,2512.840,
3351.30615,1799.598,4429.87793,2512.840,
3351.39771,1799.598,4429.96973,2512.840,
3351.48926,1799.598,4430.06104,2512.840,
3351.58081,1799.598,4430.15283,2512.840,
3351.67236,1799.598,4430.24414,2512.840,
3351.76392,1799.598,4430.33594,2512.840,
3351.85547,1800.598,4430.42725,2512.840,
3351.94678,1800.598,4430.51855,2513.840,
3352.03833,1800.598,4430.61035,2513.840,
3352.12988,1800.598,4430.70166,2513.840,
3352.22144,1800.598,4430.79346,2513.840,
3352.31299,1800.598,4430.88477,2513.840,
3352.40454,1800.598,4430.97656,2513.840,
3352.49609,1800.598,4431.06787,2513.840,
3352.58765,1801.598,4431.15918,2514.840,
3352.67896,1801.598,4431.25098,2514.840,
3352.77051,1801.598,4431.34229,2515.840,
3352.86206,1801.598,4431.43408,2515.840,
3352.95361,1802.598,4431.52539,2515.840,
3353.04517,1802.598,4431.61719,2515.840,
3353.13672,1802.598,4431.70850,2515.840,
3353.22827,1802.598,4431.79980,2516.840,
3353.31958,1803.598,4431.89160,2516.840,
3353.41113,1803.598,4431.98291,2517.840,
3353.50269,1803.598,4432.07471,2516.840,
3353.59424,1803.598,4432.16602,2517.840,
3353.68579,1803.598,4432.25781,2517.840,
3353.77734,1804.598,4432.34912,2517.840,
3353.86890,1804.598,4432.44092,2517.840,
3353.96045,1804.598,4432.53223,2517.840,
3354.05176,1804.598,4432.62354,2518.840,
3354.14331,1805.598,4432.71533,2518.840,
3354.23486,1805.598,4432.80664,2518.840,
3354.32642,1805.598,4432.89844,2518.840,
3354.41797,1806.598,4432.98975,2519.840,
3354.50952,1805.598,4433.08154,2518.840,
3354.60107,1806.598,4433.17285,2519.840,
3354.69263,1807.598,4433.26416,2519.840,
3354.78394,1806.598,4433.35596,2520.840,
3354.87549,1807.598,4433.44727,2520.840,
3354.96704,1807.598,4433.53906,2520.840,
3355.05859,1807.598,4433.63037,2521.840,
3355.15015,1808.598,4433.72217,2521.840,
3355.24170,1808.598,4433.81348,2521.840,
3355.33325,1808.598,4433.90479,2521.840,
3355.42456,1808.598,4433.99658,2521.840,
3355.51611,1808.598,4434.08789,2522.840,
3355.60767,1809.598,4434.17969,2522.840,
3355.69922,1809.598,4434.27100,2522.840,
3355.79077,1809.598,4434.36279,2522.840,
3355.88232,1809.598,4434.45410,2523.840,
3355.97388,1810.598,4434.54541,2523.840,
3356.06543,1810.598,4434.63721,2523.840,
3356.15674,1810.598,4434.72852,2523.840,
3356.24829,1810.598,4434.82031,2523.840,
3356.33984,1811.598,4434.91162,2524.840,
3356.43140,1811.598,4435.00342,2524.840,
3356.52295,1811.598,4435.09473,2524.840,
3356.61450,1811.598,4435.18652,2524.840,
3356.70605,1811.598,4435.27783,2525.840,
3356.79761,1812.598,4435.36914,2525.840,
3356.88892,1812.598,4435.46094,2525.840,
3356.98047,1811.598,4435.55225,2525.840,
3357.07202,1812.598,4435.64404,2526.840,
3357.16357,1813.598,4435.73535,2526.840,
3357.25513,1813.598,4435.82715,2526.840,
3357.34668,1813.598,4435.91846,2526.840,
3357.43823,1813.598,4436.00977,2526.840,
3357.52954,1813.598,4436.10156,2526.840,
3357.62109,1813.598,4436.19287,2527.840,
3357.71265,1814.598,4436.28467,2527.840,
3357.80420,1814.598,4436.37598,2528.840,
3357.89575,1815.598,4436.46777,2527.840,
3357.98730,1815.598,4436.55908,2528.840,
3358.07886,1815.598,4436.65039,2528.840,
3358.17041,1815.598,4436.74219,2528.840,
3358.26172,1815.598,4436.83350,2529.840,
3358.35327,1816.598,4436.92529,2529.840,
3358.44482,1815.598,4437.01660,2529.840,
3358.53638,1816.598,4437.10840,2529.840,
3358.62793,1817.598,4437.19971,2529.840,
3358.71948,1816.598,4437.29150,2530.840,
3358.81104,1817.598,4437.38281,2529.840,
3358.90234,1817.598,4437.47412,2530.840,
3358.99390,1817.598,4437.56592,2530.840,
3359.08545,1817.598,4437.65723,2530.840,
3359.17700,1818.598,4437.74902,2531.840,
3359.26855,1818.598,4437.84033,2531.840,
3359.36011,1818.598,4437.93213,2531.840,
3359.45166,1819.598,4438.02344,2531.840,
3359.54321,1819.598,4438.11475,2532.840,
3359.63452,1819.598,4438.20654,2532.840,
3359.72607,1819.598,4438.29785,2532.840,
3359.81763,1819.598,4438.38965,2532.840,
3359.90918,1819.598,4438.48096,2533.840,
3360.00073,1820.598,4438.57275,2533.840,
3360.09229,1821.598,4438.66406,2533.840,
3360.18384,1820.598,4438.75537,2533.840,
3360.27539,1821.598,4438.84717,2533.840,
3360.36670,1821.598,4438.93848,2534.840,
3360.45825,1822.598,4439.03027,2534.840,
3360.54980,1822.598,4439.12158,2534.840,
3360.64136,1822.598,4439.21338,2534.840,
3360.73291,1822.598,4439.30469,2535.840,
3360.82446,1822.598,4439.39648,2534.840,
3360.91602,1823.598,4439.48779,2535.840,
3361.00732,1823.598,4439.57910,2535.840,
3361.09888,1823.598,4439.67090,2535.840,
3361.19043,1823.598,4439.76221,2536.840,
3361.28198,1823.598,4439.85400,2536.840,
3361.37354,1824.598,4439.94531,2536.840,
3361.46509,1823.598,4440.03711,2537.840,
3361.55664,1825.598,4440.12842,2537.840,
3361.64819,1825.598,4440.21973,2537.840,
3361.73950,1825.598,4440.31152,2537.840,
3361.83105,1825.598,4440.40283,2537.840,
3361.92261,1825.598,4440.49463,2538.840,
3362.01416,1825.598,4440.58594,2537.840,
3362.10571,1826.598,4440.67773,2538.840,
3362.19727,1826.598,4440.76904,2539.840,
3362.28882,1826.598,4440.86035,2538.840,
3362.38037,1826.598,4440.95215,2539.840,
3362.47168,1827.598,4441.04346,2539.840,
3362.56323,1827.598,4441.13525,2540.840,
3362.65479,1827.598,4441.22656,2539.840,
3362.74634,1827.598,4441.31836,2540.840,
3362.83789,1827.598,4441.40967,2540.840,
3362.92944,1828.598,4441.50146,2541.840,
3363.02100,1829.598,4441.59277,2540.840,
3363.11230,1829.598,4441.68408,2541.840,
3363.20386,1829.598,4441.77588,2540.840,
3363.29541,1829.598,4441.86719,2541.840,
3363.38696,1829.598,4441.95898,2541.840,
3363.47852,1829.598,4442.05029,2542.840,
3363.57007,1830.598,4442.14209,2542.840,
3363.66162,1830.598,4442.23340,2543.840,
3363.75317,1830.598,4442.32471,2543.840,
3363.84448,1831.598,4442.41650,2543.840,
3363.93604,1831.598,4442.50781,2543.840,
3364.02759,1831.598,4442.59961,2543.840,
3364.11914,1831.598,4442.69092,2543.840,
3364.21069,1832.598,4442.78271,2544.840,
3364.30225,1831.598,4442.87402,2544.840,
3364.39380,1832.598,4442.96533,2544.840,
3364.48511,1832.598,4443.05713,2544.840,
3364.57666,1832.598,4443.14844,2544.840,
3364.66821,1833.598,4443.24023,2545.840,
3364.75977,1833.598,4443.33154,2545.840,
3364.85132,1833.598,4443.42334,2545.840,
3364.94287,1834.598,4443.51465,2546.840,
3365.03442,1834.598,4443.60645,2545.840,
3365.12598,1834.598,4443.69775,2546.840,
3365.21729,1834.598,4443.78906,2546.840,
3365.30884,1835.598,4443.88086,2546.840,
3365.40039,1835.598,4443.97217,2547.840,
3365.49194,1835.598,4444.06396,2547.840,
3365.58350,1835.598,4444.15527,2547.840,
3365.67505,1836.598,4444.24707,2547.840,
3365.76660,1835.598,4444.33838,2548.840,
3365.85815,1836.598,4444.42969,2547.840,
3365.94946,1836.598,4444.52148,2547.840,
3366.04102,1837.598,4444.61279,2548.840,
3366.13257,1837.598,4444.70459,2548.840,
3366.22412,1837.598,4444.79590,2549.840,
3366.31567,1837.598,4444.88770,2549.840,
3366.40723,1837.598,4444.97900,2549.840,
3366.49878,1837.598,4445.07031,2549.840,
3366.59009,1838.598,4445.16211,2549.840,
3366.68164,1838.598,4445.25342,2549.840,
3366.77319,1839.598,4445.34521,2550.840,
3366.86475,1838.598,4445.43652,2550.840,
3366.95630,1839.598,4445.52832,2550.840,
3367.04785,1839.598,4445.61963,2551.840,
3367.13940,1839.598,4445.71094,2551.840,
3367.23096,1839.598,4445.80273,2551.840,
3367.32227,1839.598,4445.89404,2551.840,
3367.41382,1840.598,4445.98584,2551.840,
3367.50537,1839.598,4446.07715,2552.840,
3367.59692,1839.598,4446.16895,2552.840,
3367.68848,1839.598,4446.26025,2553.840,
3367.78003,1839.598,4446.35205,2552.840,
3367.87158,1840.598,4446.44336,2553.840,
3367.96313,1839.598,4446.53467,2552.840,
3368.05444,1840.598,4446.62646,2554.840,
3368.14600,1840.598,4446.71777,2553.840,
3368.23755,1841.598,4446.80957,2553.840,
3368.32910,1841.598,4446.90088,2554.840,
3368.42065,1841.598,4446.99268,2554.840,
3368.51221,1842.598,4447.08398,2554.840,
3368.60376,1842.598,4447.17529,2554.840,
3368.69507,1842.598,4447.26709,2555.840,
3368.78662,1843.598,4447.35840,2555.840,
3368.87817,1844.598,4447.45020,2555.840,
3368.96973,1843.598,4447.54150,2555.840,
3369.06128,1845.598,4447.63330,2555.840,
3369.15283,1845.598,4447.72461,2555.840,
3369.24438,1845.598,4447.81592,2555.840,
3369.33594,1845.598,4447.90771,2556.840,
3369.42725,1846.598,4447.99902,2556.840,
3369.51880,1846.598,4448.09082,2556.840,
3369.61035,1847.598,4448.18213,2556.840,
3369.70190,1848.598,4448.27393,2556.840,
3369.79346,1848.598,4448.36523,2557.840,
3369.88501,1849.598,4448.45703,2557.840,
3369.97656,1849.598,4448.54834,2557.840,
3370.06787,1850.598,4448.63965,2558.840,
3370.15942,1849.598,4448.73145,2558.840,
3370.25098,1850.598,4448.82275,2558.840,
3370.34253,1850.598,4448.91455,2558.840,
3370.43408,1849.598,4449.00586,2559.840,
3370.52563,1850.598,4449.09766,2559.840,
3370.61719,1850.598,4449.18896,2559.840,
3370.70874,1849.598,4449.28027,2559.840,
3370.80005,1850.598,4449.37207,2559.840,
3370.89160,1850.598,4449.46338,2560.840,
3370.98315,1851.598,4449.55518,2560.840,
3371.07471,1850.598,4449.64648,2560.840,
3371.16626,1850.598,4449.73828,2560.840,
3371.25781,1850.598,4449.82959,2560.840,
3371.34937,1850.598,4449.92090,2561.840,
3371.44092,1851.598,4450.01270,2561.840,
3371.53223,1851.598,4450.10400,2561.840,
3371.62378,1851.598,4450.19580,2562.840,
3371.71533,1851.598,4450.28711,2562.840,
3371.80688,1853.598,4450.37891,2562.840,
3371.89844,1852.598,4450.47021,2562.840,
3371.98999,1852.598,4450.56201,2563.840,
3372.08154,1853.598,4450.65332,2563.840,
3372.17285,1853.598,4450.74463,2563.840,
3372.26440,1853.598,4450.83643,2563.840,
3372.35596,1853.598,4450.92773,2563.840,
3372.44751,1854.598,4451.01953,2564.840,
3372.53906,1854.598,4451.11084,2564.840,
3372.63062,1854.598,4451.20264,2564.840,
3372.72217,1854.598,4451.29395,2564.840,
3372.81372,1855.598,4451.38525,2565.840,
3372.90503,1854.598,4451.47705,2565.840,
3372.99658,1855.598,4451.56836,2565.840,
3373.08813,1855.598,4451.66016,2565.840,
3373.17969,1855.598,4451.75146,2565.840,
3373.27124,1856.598,4451.84326,2566.840,
3373.36279,1856.598,4451.93457,2566.840,
3373.45435,1856.598,4452.02588,2566.840,
3373.54590,1856.598,4452.11768,2566.840,
3373.63721,1857.598,4452.20898,2567.840,
3373.72876,1857.598,4452.30078,2567.840,
3373.82031,1857.598,4452.39209,2567.840,
3373.91187,1858.598,4452.48389,2568.840,
3374.00342,1858.598,4452.57520,2568.840,
3374.09497,1858.598,4452.66699,2568.840,
3374.18652,1858.598,4452.75830,2568.840,
3374.27783,1858.598,4452.84961,2568.840,
3374.36938,1859.598,4452.94141,2569.840,
3374.46094,1859.598,4453.03271,2569.840,
3374.55249,1859.598,4453.12451,2569.840,
3374.64404,1859.598,4453.21582,2569.840,
3374.73560,1860.598,4453.30762,2569.840,
3374.82715,1860.598,4453.39893,2569.840,
3374.91870,1860.598,4453.49023,2570.840,
3375.01001,1860.598,4453.58203,2570.840,
3375.10156,1861.598,4453.67334,2569.840,
3375.19312,1861.598,4453.76514,2570.840,
3375.28467,1861.598,4453.85645,2570.840,
3375.37622,1862.598,4453.94824,2571.840,
3375.46777,1862.598,4454.03955,2571.840,
3375.55933,1862.598,4454.13086,2572.840,
3375.65088,1862.598,4454.22266,2571.840,
3375.74219,1862.598,4454.31396,2572.840,
3375.83374,1863.598,4454.40576,2572.840,
3375.92529,1863.598,4454.49707,2572.840,
3376.01685,1864.598,4454.58887,2572.840,
3376.10840,1863.598,4454.68018,2573.840,
3376.19995,1864.598,4454.77197,2573.840,
3376.29150,1863.598,4454.86328,2573.840,
3376.38281,1864.598,4454.95459,2573.840,
3376.47437,1865.598,4455.04639,2574.840,
3376.56592,1865.598,4455.13770,2573.840,
3376.65747,1865.598,4455.22949,2573.840,
3376.74902,1865.598,4455.32080,2574.840,
3376.84058,1866.598,4455.41260,2575.840,
3376.93213,1866.598,4455.50391,2575.840,
3377.02368,1866.598,4455.59521,2575.840,
3377.11499,1867.598,4455.68701,2575.840,
3377.20654,1867.598,4455.77832,2575.840,
3377.29810,1867.598,4455.87012,2576.840,
3377.38965,1867.598,4455.96143,2576.840,
3377.48120,1868.598,4456.05322,2576.840,
3377.57275,1867.598,4456.14453,2576.840,
3377.66431,1869.598,4456.23584,2576.840,
3377.75562,1868.598,4456.32764,2576.840,
3377.84717,1869.598,4456.41895,2576.840,
3377.93872,1869.598,4456.51074,2577.840,
3378.03027,1869.598,4456.60205,2577.840,
3378.12183,1869.598,4456.69385,2578.840,
3378.21338,1869.598,4456.78516,2577.840,
3378.30493,1870.598,4456.87695,2579.840,
3378.39648,1870.598,4456.96826,2578.840,
3378.48779,1870.598,4457.05957,2578.840,
3378.57935,1870.598,4457.15137,2579.840,
3378.67090,1871.598,4457.24268,2578.840,
3378.76245,1871.598,4457.33447,2579.840,
3378.85400,1871.598,4457.42578,2579.840,
3378.94556,1871.598,4457.51758,2579.840,
3379.03711,1872.598,4457.60889,2580.840,
3379.12866,1872.598,4457.70020,2580.840,
3379.21997,1872.598,4457.79199,2580.840,
3379.31152,1873.598,4457.88330,2580.840,
3379.40308,1873.598,4457.97510,2580.840,
3379.49463,1873.598,4458.06641,2581.840,
3379.58618,1873.598,4458.15820,2581.840,
3379.67773,1873.598,4458.24951,2581.840,
3379.76929,1873.598,4458.34082,2582.840,
3379.86060,1874.598,4458.43262,2582.840,
3379.95215,1874.598,4458.52393,2582.840,
3380.04370,1874.598,4458.61572,2582.840,
3380.13525,1875.598,4458.70703,2582.840,
3380.22681,1875.598,4458.79883,2583.840,
3380.31836,1875.598,4458.89014,2583.840,
3380.40991,1875.598,4458.98145,2583.840,
3380.50146,1876.598,4459.07324,2583.840,
3380.59277,1876.598,4459.16455,2583.840,
3380.68433,1875.598,4459.25635,2583.840,
3380.77588,1876.598,4459.34766,2584.840,
3380.86743,1876.598,4459.43945,2584.840,
3380.95898,1877.598,4459.53076,2584.840,
3381.05054,1877.598,4459.62256,2584.840,
3381.14209,1877.598,4459.71387,2585.840,
3381.23364,1877.598,4459.80518,2585.840,
3381.32495,1878.598,4459.89697,2585.840,
3381.41650,1878.598,4459.98828,2585.840,
3381.50806,1878.598,4460.08008,2585.840,
3381.59961,1878.598,4460.17139,2586.840,
3381.69116,1879.598,4460.26318,2586.840,
3381.78271,1879.598,4460.35449,2586.840,
3381.87427,1879.598,4460.44580,2587.840,
3381.96558,1879.598,4460.53760,2587.840,
3382.05713,1880.598,4460.62891,2587.840,
3382.14868,1880.598,4460.72070,2587.840,
3382.24023,1880.598,4460.81201,2587.840,
3382.33179,1880.598,4460.90381,2587.840,
3382.42334,1880.598,4460.99512,2588.840,
3382.51489,1881.598,4461.08643,2588.840,
3382.60645,1881.598,4461.17822,2588.840,
3382.69775,1881.598,4461.26953,2589.840,
3382.78931,1881.598,4461.36133,2589.840,
3382.88086,1881.598,4461.45264,2589.840,
3382.97241,1882.598,4461.54443,2589.840,
3383.06396,1882.598,4461.63574,2590.840,
3383.15552,1882.598,4461.72754,2589.840,
3383.24707,1882.598,4461.81885,2590.840,
3383.33838,1882.598,4461.91016,2591.840,
3383.42993,1883.598,4462.00195,2590.840,
3383.52148,1884.598,4462.09326,2591.840,
3383.61304,1883.598,4462.18506,2591.840,
3383.70459,1884.598,4462.27637,2591.840,
3383.79614,1884.598,4462.36816,2591.840,
3383.88770,1884.598,4462.45947,2591.840,
3383.97925,1884.598,4462.55078,2591.840,
3384.07056,1885.598,4462.64258,2592.840,
3384.16211,1885.598,4462.73389,2592.840,
3384.25366,1885.598,4462.82568,2592.840,
3384.34521,1885.598,4462.91699,2593.840,
3384.43677,1886.598,4463.00879,2593.840,
3384.52832,1886.598,4463.10010,2593.840,
3384.61987,1886.598,4463.19141,2593.840,
3384.71143,1887.598,4463.28320,2593.840,
3384.80273,1886.598,4463.37451,2593.840,
3384.89429,1887.598,4463.46631,2593.840,
3384.98584,1888.598,4463.55762,2593.840,
3385.07739,1888.598,4463.64941,2594.840,
3385.16895,1888.598,4463.74072,2594.840,
3385.26050,1888.598,4463.83252,2594.840,
3385.35205,1888.598,4463.92383,2595.840,
3385.44336,1889.598,4464.01514,2595.840,
3385.53491,1889.598,4464.10693,2594.840,
3385.62646,1889.598,4464.19824,2596.840,
3385.71802,1889.598,4464.29004,2596.840,
3385.80957,1889.598,4464.38135,2596.840,
3385.90112,1890.598,4464.47314,2596.840,
3385.99268,1890.598,4464.56445,2596.840,
3386.08423,1890.598,4464.65576,2596.840,
3386.17554,1890.598,4464.74756,2597.840,
3386.26709,1889.598,4464.83887,2598.840,
3386.35864,1889.598,4464.93066,2598.840,
3386.45020,1889.598,4465.02197,2598.840,
3386.54175,1889.598,4465.11377,2598.840,
3386.63330,1888.598,4465.20508,2598.840,
3386.72485,1889.598,4465.29639,2598.840,
3386.81641,1889.598,4465.38818,2598.840,
3386.90771,1889.598,4465.47949,2598.840,
3386.99927,1890.598,4465.57129,2598.840,
3387.09082,1891.598,4465.66260,2599.840,
3387.18237,1891.598,4465.75439,2598.840,
3387.27393,1891.598,4465.84570,2599.840,
3387.36548,1892.598,4465.93750,2599.840,
3387.45703,1893.598,4466.02881,2599.840,
3387.54834,1893.598,4466.12012,2599.840,
3387.63989,1893.598,4466.21191,2599.840,
3387.73145,1894.598,4466.30322,2600.840,
3387.82300,1894.598,4466.39502,2600.840,
3387.91455,1895.598,4466.48633,2600.840,
3388.00610,1895.598,4466.57813,2601.840,
3388.09766,1896.598,4466.66943,2600.840,
3388.18921,1896.598,4466.76074,2601.840,
3388.28052,1897.598,4466.85254,2601.840,
3388.37207,1897.598,4466.94385,2601.840,
3388.46362,1897.598,4467.03564,2601.840,
3388.55518,1898.598,4467.12695,2603.840,
3388.64673,1899.598,4467.21875,2602.840,
3388.73828,1899.598,4467.31006,2602.840,
3388.82983,1901.598,4467.40137,2603.840,
3388.92114,1901.598,4467.49316,2603.840,
3389.01270,1901.598,4467.58447,2603.840,
3389.10425,1901.598,4467.67627,2603.840,
3389.19580,1901.598,4467.76758,2603.840,
3389.28735,1901.598,4467.85938,2604.840,
3389.37891,1902.598,4467.95068,2603.840,
3389.47046,1902.598,4468.04248,2604.840,
3389.56201,1902.598,4468.13379,2604.840,
3389.65332,1902.598,4468.22510,2604.840,
3389.74487,1903.598,4468.31689,2605.840,
3389.83643,1902.598,4468.40820,2605.840,
3389.92798,1902.598,4468.50000,2605.840,
3390.01953,1902.598,4468.59131,2606.840,
3390.11108,1903.598,4468.68311,2606.840,
3390.20264,1902.598,4468.77441,2606.840,
3390.29419,1902.598,4468.86572,2606.840,
3390.38550,1903.598,4468.95752,2607.840,
3390.47705,1902.598,4469.04883,2606.840,
3390.56860,1903.598,4469.14063,2607.840,
3390.66016,1903.598,4469.23193,2607.840,
3390.75171,1903.598,4469.32373,2607.840,
3390.84326,1904.598,4469.41504,2607.840,
3390.93481,1904.598,4469.50635,2607.840,
3391.02612,1904.598,4469.59814,2607.840,
3391.11768,1904.598,4469.68945,2607.840,
3391.20923,1904.598,4469.78125,2607.840,
3391.30078,1905.598,4469.87256,2608.840,
3391.39233,1905.598,4469.96436,2608.840,
3391.48389,1905.598,4470.05566,2609.840,
3391.57544,1905.598,4470.14746,2609.840,
3391.66699,1905.598,4470.23877,2609.840,
3391.75830,1906.598,4470.33008,2609.840,
3391.84985,1906.598,4470.42188,2610.840,
3391.94141,1906.598,4470.51318,2610.840,
3392.03296,1906.598,4470.60498,2610.840,
3392.12451,1907.598,4470.69629,2610.840,
3392.21606,1907.598,4470.78809,2611.840,
3392.30762,1908.598,4470.87939,2610.840,
3392.39917,1907.598,4470.97070,2610.840,
3392.49048,1908.598,4471.06250,2611.840,
3392.58203,1908.598,4471.15381,2611.840,
3392.67358,1908.598,4471.24561,2611.840,
3392.76514,1908.598,4471.33691,2612.840,
3392.85669,1909.598,4471.42871,2612.840,
3392.94824,1909.598,4471.52002,2612.840,
3393.03979,1909.598,4471.61133,2612.840,
3393.13110,1909.598,4471.70313,2613.840,
3393.22266,1909.598,4471.79443,2613.840,
3393.31421,1909.598,4471.88623,2613.840,
3393.40576,1910.598,4471.97754,2613.840,
3393.49731,1910.598,4472.06934,2613.840,
3393.58887,1911.598,4472.16064,2614.840,
3393.68042,1911.598,4472.25195,2614.840,
3393.77197,1912.598,4472.34375,2614.840,
3393.86328,1911.598,4472.43506,2614.840,
3393.95483,1912.598,4472.52686,2614.840,
3394.04639,1912.598,4472.61816,2615.840,
3394.13794,1912.598,4472.70996,2615.840,
3394.22949,1913.598,4472.80127,2615.840,
3394.32104,1913.598,4472.89307,2615.840,
3394.41260,1913.598,4472.98438,2616.840,
3394.50415,1913.598,4473.07568,2616.840,
3394.59546,1913.598,4473.16748,2616.840,
3394.68701,1913.598,4473.25879,2616.840,
3394.77856,1914.598,4473.35059,2616.840,
3394.87012,1914.598,4473.44189,2617.840,
3394.96167,1915.598,4473.53369,2617.840,
3395.05322,1915.598,4473.62500,2617.840,
3395.14478,1915.598,4473.71631,2617.840,
3395.23608,1915.598,4473.80811,2618.840,
3395.32764,1915.598,4473.89941,2618.840,
3395.41919,1915.598,4473.99121,2618.840,
3395.51074,1916.598,4474.08252,2618.840,
3395.60229,1916.598,4474.17432,2618.840,
3395.69385,1916.598,4474.26563,2618.840,
3395.78540,1917.598,4474.35693,2618.840,
3395.87695,1917.598,4474.44873,2619.840,
3395.96826,1917.598,4474.54004,2619.840,
3396.05981,1917.598,4474.63184,2620.840,
3396.15137,1918.598,4474.72314,2620.840,
3396.24292,1918.598,4474.81494,2620.840,
3396.33447,1918.598,4474.90625,2620.840,
3396.42603,1919.598,4474.99805,2620.840,
3396.51758,1919.598,4475.08936,2620.840,
3396.60889,1919.598,4475.18066,2620.840,
3396.70044,1921.598,4475.27246,2621.840,
3396.79199,1920.598,4475.36377,2621.840,
3396.88354,1920.598,4475.45557,2621.840,
3396.97510,1920.598,4475.54688,2621.840,
3397.06665,1920.598,4475.63867,2621.840,
3397.15820,1920.598,4475.72998,2621.840,
3397.24976,1921.598,4475.82129,2622.840,
3397.34106,1921.598,4475.91309,2623.840,
3397.43262,1921.598,4476.00439,2623.840,
3397.52417,1921.598,4476.09619,2622.840,
3397.61572,1922.598,4476.18750,2623.840,
3397.70728,1922.598,4476.27930,2623.840,
3397.79883,1922.598,4476.37061,2623.840,
3397.89038,1922.598,4476.46191,2623.840,
3397.98193,1923.598,4476.55371,2623.840,
3398.07324,1923.598,4476.64502,2623.840,
3398.16479,1923.598,4476.73682,2624.840,
3398.25635,1923.598,4476.82813,2624.840,
3398.34790,1923.598,4476.91992,2624.840,
3398.43945,1924.598,4477.01123,2624.840,
3398.53101,1924.598,4477.10303,2625.840,
3398.62256,1924.598,4477.19434,2625.840,
3398.71387,1924.598,4477.28564,2625.840,
3398.80542,1925.598,4477.37744,2626.840,
3398.89697,1924.598,4477.46875,2626.840,
3398.98853,1926.598,4477.56055,2626.840,
3399.08008,1926.598,4477.65186,2626.840,
3399.17163,1926.598,4477.74365,2626.840,
3399.26318,1926.598,4477.83496,2626.840,
3399.35474,1926.598,4477.92627,2627.840,
3399.44604,1927.598,4478.01807,2627.840,
3399.53760,1926.598,4478.10938,2627.840,
3399.62915,1928.598,4478.20117,2627.840,
3399.72070,1928.598,4478.29248,2627.840,
3399.81226,1928.598,4478.38428,2627.840,
3399.90381,1928.598,4478.47559,2628.840,
3399.99536,1928.598,4478.56689,2628.840,
3400.08691,1929.598,4478.65869,2628.840,
3400.17822,1929.598,4478.75000,2628.840,
3400.26978,1929.598,4478.84180,2630.840,
3400.36133,1929.598,4478.93311,2629.840,
3400.45288,1929.598,4479.02490,2628.840,
3400.54443,1930.598,4479.11621,2629.840,
3400.63599,1930.598,4479.20801,2629.840,
3400.72754,1930.598,4479.29932,2630.840,
3400.81885,1930.598,4479.39063,2630.840,
3400.91040,1931.598,4479.48242,2630.840,
3401.00195,1931.598,4479.57373,2630.840,
3401.09351,1932.598,4479.66553,2630.840,
3401.18506,1931.598,4479.75684,2630.840,
3401.27661,1932.598,4479.84863,2631.840,
3401.36816,1932.598,4479.93994,2631.840,
3401.45972,1933.598,4480.03125,2631.840,
3401.55103,1933.598,4480.12305,2631.840,
3401.64258,1933.598,4480.21436,2631.840,
3401.73413,1934.598,4480.30615,2632.840,
3401.82568,1934.598,4480.39746,2631.840,
3401.91724,1934.598,4480.48926,2632.840,
3402.00879,1934.598,4480.58057,2632.840,
3402.10034,1934.598,4480.67188,2632.840,
3402.19165,1934.598,4480.76367,2633.840,
3402.28320,1934.598,4480.85498,2633.840,
3402.37476,1935.598,4480.94678,2633.840,
3402.46631,1935.598,4481.03809,2633.840,
3402.55786,1936.598,4481.12988,2633.840,
3402.64941,1935.598,4481.22119,2633.840,
3402.74097,1936.598,4481.31299,2634.840,
3402.83252,1936.598,4481.40430,2634.840,
3402.92383,1936.598,4481.49561,2634.840,
3403.01538,1936.598,4481.58740,2634.840,
3403.10693,1937.598,4481.67871,2634.840,
3403.19849,1937.598,4481.77051,2635.840,
3403.29004,1937.598,4481.86182,2635.840,
3403.38159,1937.598,4481.95361,2635.840,
3403.47314,1937.598,4482.04492,2635.840,
3403.56470,1938.598,4482.13623,2636.840,
3403.65601,1938.598,4482.22803,2636.840,
3403.74756,1938.598,4482.31934,2636.840,
3403.83911,1939.598,4482.41113,2637.840,
3403.93066,1939.598,4482.50244,2636.840,
3404.02222,1940.598,4482.59424,2636.840,
3404.11377,1941.598,4482.68555,2635.840,
3404.20532,1940.598,4482.77686,2635.840,
3404.29663,1940.598,4482.86865,2635.840,
3404.38818,1940.598,4482.95996,2635.840,
3404.47974,1941.598,4483.05176,2635.840,
3404.57129,1941.598,4483.14307,2635.840,
3404.66284,1942.598,4483.23486,2636.840,
3404.75439,1942.598,4483.32617,2637.840,
3404.84595,1942.598,4483.41748,2637.840,
3404.93750,1942.598,4483.50928,2638.840,
3405.02881,1943.598,4483.60059,2638.840,
3405.12036,1944.598,4483.69238,2638.840,
3405.21191,1944.598,4483.78369,2639.840,
3405.30347,1945.598,4483.87549,2639.840,
3405.39502,1946.598,4483.96680,2639.840,
3405.48657,1947.598,4484.05859,2640.840,
3405.57813,1947.598,4484.14990,2640.840,
3405.66968,1947.598,4484.24121,2640.840,
3405.76099,1947.598,4484.33301,2640.840,
3405.85254,1947.598,4484.42432,2641.840,
3405.94409,1948.598,4484.51611,2641.840,
3406.03564,1947.598,4484.60742,2641.840,
3406.12720,1947.598,4484.69922,2642.840,
3406.21875,1947.598,4484.79053,2641.840,
3406.31030,1947.598,4484.88184,2641.840,
3406.40161,1947.598,4484.97363,2642.840,
3406.49316,1947.598,4485.06494,2642.840,
3406.58472,1947.598,4485.15674,2642.840,
3406.67627,1948.598,4485.24805,2642.840,
3406.76782,1947.598,4485.33984,2643.840,
3406.85938,1948.598,4485.43115,2643.840,
3406.95093,1948.598,4485.52246,2643.840,
3407.04248,1948.598,4485.61426,2644.840,
3407.13379,1948.598,4485.70557,2644.840,
3407.22534,1949.598,4485.79736,2643.840,
3407.31689,1948.598,4485.88867,2644.840,
3407.40845,1948.598,4485.98047,2644.840,
3407.50000,1948.598,4486.07178,2644.840,
3407.59155,1947.598,4486.16357,2645.840,
3407.68311,1947.598,4486.25488,2645.840,
3407.77441,1947.598,4486.34619,2644.840,
3407.86597,1947.598,4486.43799,2645.840,
3407.95752,1947.598,4486.52930,2645.840,
3408.04907,1947.598,4486.62109,2645.840,
3408.14063,1947.598,4486.71240,2646.840,
3408.23218,1948.598,4486.80420,2646.840,
3408.32373,1948.598,4486.89551,2645.840,
3408.41528,1950.598,4486.98682,2646.840,
3408.50659,1949.598,4487.07861,2646.840,
3408.59814,1950.598,4487.16992,2646.840,
3408.68970,1950.598,4487.26172,2647.840,
3408.78125,1951.598,4487.35303,2647.840,
3408.87280,1951.598,4487.44482,2647.840,
3408.96436,1951.598,4487.53613,2647.840,
3409.05591,1952.598,4487.62744,2648.840,
3409.14746,1953.598,4487.71924,2648.840,
3409.23877,1953.598,4487.81055,2648.840,
3409.33032,1953.598,4487.90234,2648.840,
3409.42188,1954.598,4487.99365,2648.840,
3409.51343,1954.598,4488.08545,2648.840,
3409.60498,1954.598,4488.17676,2648.840,
3409.69653,1954.598,4488.26855,2649.840,
3409.78809,1955.598,4488.35986,2649.840,
3409.87939,1956.598,4488.45117,2649.840,
3409.97095,1956.598,4488.54297,2649.840,
3410.06250,1956.598,4488.63428,2650.840,
3410.15405,1956.598,4488.72607,2649.840,
3410.24561,1956.598,4488.81738,2650.840,
3410.33716,1956.598,4488.90918,2650.840,
3410.42871,1957.598,4489.00049,2651.840,
3410.52026,1957.598,4489.09180,2652.840,
3410.61157,1957.598,4489.18359,2651.840,
3410.70313,1958.598,4489.27490,2651.840,
3410.79468,1957.598,4489.36670,2652.840,
3410.88623,1958.598,4489.45801,2652.840,
3410.97778,1958.598,4489.54980,2652.840,
3411.06934,1959.598,4489.64111,2652.840,
3411.16089,1959.598,4489.73242,2652.840,
3411.25244,1959.598,4489.82422,2652.840,
3411.34375,1960.598,4489.91553,2652.840,
3411.43530,1959.598,4490.00732,2652.840,
3411.52686,1959.598,4490.09863,2653.840,
3411.61841,1960.598,4490.19043,2653.840,
3411.70996,1960.598,4490.28174,2653.840,
3411.80151,1960.598,4490.37354,2653.840,
3411.89307,1961.598,4490.46484,2653.840,
3411.98438,1961.598,4490.55615,2654.840,
3412.07593,1962.598,4490.64795,2654.840,
3412.16748,1961.598,4490.73926,2654.840,
3412.25903,1962.598,4490.83105,2654.840,
3412.35059,1962.598,4490.92236,2655.840,
3412.44214,1962.598,4491.01416,2655.840,
3412.53369,1962.598,4491.10547,2655.840,
3412.62524,1963.598,4491.19678,2656.840,
3412.71655,1963.598,4491.28857,2656.840,
3412.80811,1963.598,4491.37988,2656.840,
3412.89966,1963.598,4491.47168,2656.840,
3412.99121,1963.598,4491.56299,2657.840,
3413.08276,1964.598,4491.65479,2657.840,
3413.17432,1964.598,4491.74609,2657.840,
3413.26587,1964.598,4491.83740,2657.840,
3413.35742,1964.598,4491.92920,2657.840,
3413.44873,1965.598,4492.02051,2658.840,
3413.54028,1965.598,4492.11230,2658.840,
3413.63184,1965.598,4492.20361,2658.840,
3413.72339,1966.598,4492.29541,2657.840,
3413.81494,1965.598,4492.38672,2658.840,
3413.90649,1966.598,4492.47852,2658.840,
3413.99805,1967.598,4492.56982,2658.840,
3414.08936,1967.598,4492.66113,2659.840,
3414.18091,1967.598,4492.75293,2659.840,
3414.27246,1968.598,4492.84424,2659.840,
3414.36401,1968.598,4492.93604,2659.840,
3414.45557,1968.598,4493.02734,2659.840,
3414.54712,1968.598,4493.11914,2659.840,
3414.63867,1968.598,4493.21045,2659.840,
3414.73022,1968.598,4493.30176,2659.840,
3414.82153,1969.598,4493.39355,2660.840,
3414.91309,1969.598,4493.48486,2661.840,
3415.00464,1969.598,4493.57666,2660.840,
3415.09619,1970.598,4493.66797,2660.840,
3415.18774,1970.598,4493.75977,2661.840,
3415.27930,1970.598,4493.85107,2661.840,
3415.37085,1970.598,4493.94238,2661.840,
3415.46216,1971.598,4494.03418,2662.840,
3415.55371,1971.598,4494.12549,2662.840,
3415.64526,1971.598,4494.21729,2662.840,
3415.73682,1972.598,4494.30859,2662.840,
3415.82837,1972.598,4494.40039,2662.840,
3415.91992,1972.598,4494.49170,2662.840,
3416.01147,1972.598,4494.58350,2662.840,
3416.10303,1972.598,4494.67480,2663.840,
3416.19434,1972.598,4494.76611,2663.840,
3416.28589,1973.598,4494.85791,2663.840,
3416.37744,1973.598,4494.94922,2664.840,
3416.46899,1973.598,4495.04102,2663.840,
3416.56055,1973.598,4495.13232,2664.840,
3416.65210,1974.598,4495.22412,2664.840,
3416.74365,1974.598,4495.31543,2664.840,
3416.83521,1974.598,4495.40674,2664.840,
3416.92651,1974.598,4495.49854,2664.840,
3417.01807,1975.598,4495.58984,2665.840,
3417.10962,1975.598,4495.68164,2665.840,
3417.20117,1976.598,4495.77295,2665.840,
3417.29272,1975.598,4495.86475,2664.840,
3417.38428,1976.598,4495.95605,2665.840,
3417.47583,1976.598,4496.04736,2665.840,
3417.56714,1976.598,4496.13916,2666.840,
3417.65869,1977.598,4496.23047,2665.840,
3417.75024,1977.598,4496.32227,2666.840,
3417.84180,1977.598,4496.41357,2666.840,
3417.93335,1977.598,4496.50537,2666.840,
3418.02490,1977.598,4496.59668,2667.840,
3418.11646,1977.598,4496.68799,2667.840,
3418.20801,1978.598,4496.77979,2667.840,
3418.29932,1978.598,4496.87109,2667.840,
3418.39087,1979.598,4496.96289,2668.840,
3418.48242,1979.598,4497.05420,2668.840,
3418.57397,1979.598,4497.14600,2668.840,
3418.66553,1979.598,4497.23730,2668.840,
3418.75708,1979.598,4497.32910,2669.840,
3418.84863,1980.598,4497.42041,2668.840,
3418.94019,1980.598,4497.51172,2669.840,
3419.03149,1980.598,4497.60352,2669.840,
3419.12305,1980.598,4497.69482,2669.840,
3419.21460,1981.598,4497.78662,2669.840,
3419.30615,1981.598,4497.87793,2670.840,
3419.39771,1981.598,4497.96973,2669.840,
3419.48926,1982.598,4498.06104,2670.840,
3419.58081,1981.598,4498.15234,2670.840,
3419.67212,1982.598,4498.24414,2670.840,
3419.76367,1982.598,4498.33545,2670.840,
3419.85522,1982.598,4498.42725,2671.840,
3419.94678,1982.598,4498.51855,2671.840,
3420.03833,1983.598,4498.61035,2671.840,
3420.12988,1983.598,4498.70166,2671.840,
3420.22144,1983.598,4498.79297,2671.840,
3420.31299,1983.598,4498.88477,2671.840,
3420.40430,1984.598,4498.97607,2672.840,
3420.49585,1984.598,4499.06787,2672.840,
3420.58740,1985.598,4499.15918,2672.840,
3420.67896,1985.598,4499.25098,2672.840,
3420.77051,1985.598,4499.34229,2673.840,
3420.86206,1985.598,4499.43408,2672.840,
3420.95361,1985.598,4499.52539,2673.840,
3421.04492,1986.598,4499.61670,2673.840,
3421.13647,1986.598,4499.70850,2673.840,
3421.22803,1986.598,4499.79980,2673.840,
3421.31958,1986.598,4499.89160,2673.840,
3421.41113,1987.598,4499.98291,2673.840,
3421.50269,1987.598,4500.07471,2674.840,
3421.59424,1987.598,4500.16602,2674.840,
3421.68579,1987.598,4500.25732,2674.840,
3421.77710,1987.598,4500.34912,2674.840,
3421.86865,1988.598,4500.44043,2675.840,
3421.96021,1988.598,4500.53223,2675.840,
3422.05176,1988.598,4500.62354,2675.840,
3422.14331,1989.598,4500.71533,2675.840,
3422.23486,1989.598,4500.80664,2676.840,
3422.32642,1989.598,4500.89795,2676.840,
3422.41797,1990.598,4500.98975,2676.840,
3422.50928,1990.598,4501.08105,2676.840,
3422.60083,1990.598,4501.17285,2676.840,
3422.69238,1990.598,4501.26416,2676.840,
3422.78394,1990.598,4501.35596,2675.840,
3422.87549,1991.598,4501.44727,2676.840,
3422.96704,1991.598,4501.53906,2676.840,
3423.05859,1992.598,4501.63037,2676.840,
3423.14990,1991.598,4501.72168,2675.840,
3423.24146,1991.598,4501.81348,2676.840,
3423.33301,1992.598,4501.90479,2676.840,
3423.42456,1992.598,4501.99658,2677.840,
3423.51611,1992.598,4502.08789,2676.840,
3423.60767,1993.598,4502.17969,2677.840,
3423.69922,1993.598,4502.27100,2678.840,
3423.79077,1993.598,4502.36230,2678.840,
3423.88208,1993.598,4502.45410,2678.840,
3423.97363,1994.598,4502.54541,2679.840,
3424.06519,1994.598,4502.63721,2679.840,
3424.15674,1995.598,4502.72852,2679.840,
3424.24829,1995.598,4502.82031,2679.840,
3424.33984,1995.598,4502.91162,2680.840,
3424.43140,1996.598,4503.00293,2680.840,
3424.52295,1997.598,4503.09473,2680.840,
3424.61426,1997.598,4503.18604,2681.840,
3424.70581,1997.598,4503.27783,2680.840,
3424.79736,1997.598,4503.36914,2680.840,
3424.88892,1997.598,4503.46094,2681.840,
3424.98047,1997.598,4503.55225,2681.840,
3425.07202,1998.598,4503.64404,2681.840,
3425.16357,1998.598,4503.73535,2683.840,
3425.25488,1998.598,4503.82666,2682.840,
3425.34644,1998.598,4503.91846,2682.840,
3425.43799,1998.598,4504.00977,2682.840,
3425.52954,1998.598,4504.10156,2683.840,
3425.62109,1999.598,4504.19287,2682.840,
3425.71265,1999.598,4504.28467,2683.840,
3425.80420,1999.598,4504.37598,2683.840,
3425.89575,1999.598,4504.46729,2683.840,
3425.98706,2000.598,4504.55908,2683.840,
3426.07861,2000.598,4504.65039,2683.840,
3426.17017,1999.598,4504.74219,2683.840,
3426.26172,1999.598,4504.83350,2684.840,
3426.35327,2000.598,4504.92529,2684.840,
3426.44482,2000.598,4505.01660,2684.840,
3426.53638,2000.598,4505.10791,2684.840,
3426.62769,2000.598,4505.19971,2685.840,
3426.71924,2001.598,4505.29102,2685.840,
3426.81079,2000.598,4505.38281,2685.840,
3426.90234,2001.598,4505.47412,2685.840,
3426.99390,2001.598,4505.56592,2685.840,
3427.08545,2001.598,4505.65723,2685.840,
3427.17700,2002.598,4505.74902,2685.840,
3427.26855,2002.598,4505.84033,2685.840,
3427.35986,2002.598,4505.93164,2686.840,
3427.45142,2003.598,4506.02344,2686.840,
3427.54297,2003.598,4506.11475,2686.840,
3427.63452,2003.598,4506.20654,2687.840,
3427.72607,2004.598,4506.29785,2687.840,
3427.81763,2004.598,4506.38965,2687.840,
3427.90918,2005.598,4506.48096,2687.840,
3428.00073,2005.598,4506.57227,2687.840,
3428.09204,2005.598,4506.66406,2688.840,
3428.18359,2005.598,4506.75537,2688.840,
3428.27515,2005.598,4506.84717,2688.840,
3428.36670,2005.598,4506.93848,2688.840,
3428.45825,2006.598,4507.03027,2689.840,
3428.54980,2006.598,4507.12158,2688.840,
3428.64136,2006.598,4507.21289,2689.840,
3428.73267,2007.598,4507.30469,2689.840,
3428.82422,2007.598,4507.39600,2689.840,
3428.91577,2007.598,4507.48779,2689.840,
3429.00732,2007.598,4507.57910,2689.840,
3429.09888,2007.598,4507.67090,2689.840,
3429.19043,2008.598,4507.76221,2689.840,
3429.28198,2008.598,4507.85352,2689.840,
3429.37354,2009.598,4507.94531,2690.840,
3429.46484,2009.598,4508.03662,2690.840,
3429.55640,2009.598,4508.12842,2691.840,
3429.64795,2009.598,4508.21973,2691.840,
3429.73950,2009.598,4508.31152,2690.840,
3429.83105,2009.598,4508.40283,2691.840,
3429.92261,2009.598,4508.49463,2691.840,
3430.01416,2010.598,4508.58594,2691.840,
3430.10571,2010.598,4508.67725,2691.840,
3430.19702,2011.598,4508.76904,2692.840,
3430.28857,2011.598,4508.86035,2692.840,
3430.38013,2011.598,4508.95215,2692.840,
3430.47168,2011.598,4509.04346,2692.840,
3430.56323,2011.598,4509.13525,2692.840,
3430.65479,2012.598,4509.22656,2692.840,
3430.74634,2012.598,4509.31787,2693.840,
3430.83765,2012.598,4509.40967,2693.840,
3430.92920,2012.598,4509.50098,2693.840,
3431.02075,2013.598,4509.59277,2694.840,
3431.11230,2013.598,4509.68408,2694.840,
3431.20386,2013.598,4509.77588,2694.840,
3431.29541,2013.598,4509.86719,2694.840,
3431.38696,2014.598,4509.95850,2694.840,
3431.47852,2014.598,4510.05029,2695.840,
3431.56982,2014.598,4510.14160,2694.840,
3431.66138,2015.598,4510.23340,2694.840,
3431.75293,2015.598,4510.32471,2695.840,
3431.84448,2016.598,4510.41650,2695.840,
3431.93604,2015.598,4510.50781,2696.840,
3432.02759,2015.598,4510.59961,2695.840,
3432.11914,2016.598,4510.69092,2696.840,
3432.21069,2016.598,4510.78223,2695.840,
3432.30200,2016.598,4510.87402,2696.840,
3432.39355,2016.598,4510.96533,2696.840,
3432.48511,2017.598,4511.05713,2697.840,
3432.57666,2017.598,4511.14844,2696.840,
3432.66821,2017.598,4511.24023,2697.840,
3432.75977,2017.598,4511.33154,2697.840,
3432.85132,2018.598,4511.42285,2697.840,
3432.94263,2018.598,4511.51465,2698.840,
3433.03418,2018.598,4511.60596,2697.840,
3433.12573,2018.598,4511.69775,2698.840,
3433.21729,2019.598,4511.78906,2698.840,
3433.30884,2020.598,4511.88086,2698.840,
3433.40039,2019.598,4511.97217,2698.840,
3433.49194,2020.598,4512.06348,2699.840,
3433.58350,2020.598,4512.15527,2698.840,
3433.67480,2020.598,4512.24658,2699.840,
3433.76636,2020.598,4512.33838,2699.840,
3433.85791,2021.598,4512.42969,2699.840,
3433.94946,2020.598,4512.52148,2700.840,
3434.04102,2021.598,4512.61279,2699.840,
3434.13257,2021.598,4512.70459,2700.840,
3434.22412,2021.598,4512.79590,2699.840,
3434.31543,2021.598,4512.88721,2700.840,
3434.40698,2022.598,4512.97900,2700.840,
3434.49854,2022.598,4513.07031,2700.840,
3434.59009,2022.598,4513.16211,2700.840,
3434.68164,2023.598,4513.25342,2701.840,
3434.77319,2023.598,4513.34521,2701.840,
3434.86475,2023.598,4513.43652,2700.840,
3434.95630,2023.598,4513.52783,2701.840,
3435.04761,2023.598,4513.61963,2701.840,
3435.13916,2023.598,4513.71094,2702.840,
3435.23071,2024.598,4513.80273,2702.840,
3435.32227,2024.598,4513.89404,2702.840,
3435.41382,2024.598,4513.98584,2702.840,
3435.50537,2024.598,4514.07715,2702.840,
3435.59692,2025.598,4514.16846,2703.840,
3435.68848,2025.598,4514.26025,2703.840,
3435.77979,2025.598,4514.35156,2703.840,
3435.87134,2025.598,4514.44336,2703.840,
3435.96289,2026.598,4514.53467,2703.840,
3436.05444,2026.598,4514.62646,2704.840,
3436.14600,2026.598,4514.71777,2704.840,
3436.23755,2027.598,4514.80957,2704.840,
3436.32910,2027.598,4514.90088,2704.840,
3436.42041,2027.598,4514.99219,2704.840,
3436.51196,2027.598,4515.08398,2705.840,
3436.60352,2027.598,4515.17529,2705.840,
3436.69507,2028.598,4515.26709,2705.840,
3436.78662,2028.598,4515.35840,2705.840,
3436.87817,2028.598,4515.45020,2705.840,
3436.96973,2029.598,4515.54150,2705.840,
3437.06128,2028.598,4515.63281,2706.840,
3437.15259,2029.598,4515.72461,2706.840,
3437.24414,2030.598,4515.81592,2706.840,
3437.33569,2030.598,4515.90771,2707.840,
3437.42725,2030.598,4515.99902,2706.840,
3437.51880,2030.598,4516.09082,2706.840,
3437.61035,2031.598,4516.18213,2706.840,
3437.70190,2032.598,4516.27344,2707.840,
3437.79346,2031.598,4516.36523,2707.840,
3437.88477,2031.598,4516.45654,2707.840,
3437.97632,2032.598,4516.54834,2707.840,
3438.06787,2032.598,4516.63965,2707.840,
3438.15942,2032.598,4516.73145,2708.840,
3438.25098,2032.598,4516.82275,2708.840,
3438.34253,2032.598,4516.91455,2709.840,
3438.43408,2033.598,4517.00586,2708.840,
3438.52539,2033.598,4517.09717,2708.840,
3438.61694,2033.598,4517.18896,2709.840,
3438.70850,2033.598,4517.28027,2709.840,
3438.80005,2034.598,4517.37207,2709.840,
3438.89160,2034.598,4517.46338,2709.840,
3438.98315,2034.598,4517.55518,2709.840,
3439.07471,2035.598,4517.64648,2710.840,
3439.16626,2034.598,4517.73779,2710.840,
3439.25757,2035.598,4517.82959,2710.840,
3439.34912,2035.598,4517.92090,2710.840,
3439.44067,2035.598,4518.01270,2710.840,
3439.53223,2036.598,4518.10400,2710.840,
3439.62378,2036.598,4518.19580,2710.840,
3439.71533,2036.598,4518.28711,2711.840,
3439.80688,2037.598,4518.37842,2711.840,
3439.89819,2037.598,4518.47021,2710.840,
3439.98975,2037.598,4518.56152,2711.840,
3440.08130,2038.598,4518.65332,2711.840,
3440.17285,2038.598,4518.74463,2711.840,
3440.26440,2037.598,4518.83643,2712.840,
3440.35596,2038.598,4518.92773,2712.840,
3440.44751,2038.598,4519.01953,2712.840,
3440.53906,2038.598,4519.11084,2712.840,
3440.63037,2039.598,4519.20215,2712.840,
3440.72192,2039.598,4519.29395,2712.840,
3440.81348,2039.598,4519.38525,2713.840,
3440.90503,2039.598,4519.47705,2713.840,
3440.99658,2039.598,4519.56836,2713.840,
3441.08813,2040.598,4519.66016,2713.840,
3441.17969,2040.598,4519.75146,2713.840,
3441.27124,2040.598,4519.84277,2714.840,
3441.36255,2041.598,4519.93457,2713.840,
3441.45410,2041.598,4520.02588,2714.840,
3441.54565,2041.598,4520.11768,2714.840,
3441.63721,2042.598,4520.20898,2715.840,
3441.72876,2042.598,4520.30078,2714.840,
3441.82031,2042.598,4520.39209,2715.840,
3441.91187,2043.598,4520.48340,2716.840,
3442.00317,2042.598,4520.57520,2716.840,
3442.09473,2043.598,4520.66650,2716.840,
3442.18628,2044.598,4520.75830,2716.840,
3442.27783,2043.598,4520.84961,2717.840,
3442.36938,2043.598,4520.94141,2717.840,
3442.46094,2043.598,4521.03271,2717.840,
3442.55249,2044.598,4521.12402,2717.840,
3442.64404,2044.598,4521.21582,2717.840,
3442.73535,2045.598,4521.30713,2717.840,
3442.82690,2046.598,4521.39893,2717.840,
3442.91846,2046.598,4521.49023,2717.840,
3443.01001,2047.598,4521.58203,2717.840,
3443.10156,2048.598,4521.67334,2717.840,
3443.19312,2048.598,4521.76514,2717.840,
3443.28467,2049.598,4521.85645,2718.840,
3443.37622,2049.598,4521.94775,2718.840,
3443.46753,2049.598,4522.03955,2717.840,
3443.55908,2050.598,4522.13086,2718.840,
3443.65063,2049.598,4522.22266,2718.840,
3443.74219,2049.598,4522.31396,2718.840,
3443.83374,2049.598,4522.40576,2718.840,
3443.92529,2049.598,4522.49707,2718.840,
3444.01685,2049.598,4522.58838,2719.840,
3444.10815,2049.598,4522.68018,2719.840,
3444.19971,2049.598,4522.77148,2720.840,
3444.29126,2049.598,4522.86328,2720.840,
3444.38281,2049.598,4522.95459,2720.840,
3444.47437,2050.598,4523.04639,2720.840,
3444.56592,2050.598,4523.13770,2720.840,
3444.65747,2050.598,4523.22900,2720.840,
3444.74902,2050.598,4523.32080,2720.840,
3444.84033,2050.598,4523.41211,2721.840,
3444.93188,2050.598,4523.50391,2720.840,
3445.02344,2050.598,4523.59521,2721.840,
3445.11499,2050.598,4523.68701,2721.840,
3445.20654,2050.598,4523.77832,2721.840,
3445.29810,2049.598,4523.87012,2721.840,
3445.38965,2048.598,4523.96143,2722.840,
3445.48096,2048.598,4524.05273,2721.840,
3445.57251,2049.598,4524.14453,2722.840,
3445.66406,2048.598,4524.23584,2722.840,
3445.75562,2049.598,4524.32764,2722.840,
3445.84717,2049.598,4524.41895,2722.840,
3445.93872,2049.598,4524.51074,2723.840,
3446.03027,2050.598,4524.60205,2723.840,
3446.12183,2051.598,4524.69336,2723.840,
3446.21313,2051.598,4524.78516,2723.840,
3446.30469,2051.598,4524.87646,2723.840,
3446.39624,2052.598,4524.96826,2724.840,
3446.48779,2053.598,4525.05957,2723.840,
3446.57935,2053.598,4525.15137,2724.840,
3446.67090,2054.598,4525.24268,2724.840,
3446.76245,2054.598,4525.33398,2724.840,
3446.85400,2055.598,4525.42578,2724.840,
3446.94531,2055.598,4525.51709,2724.840,
3447.03687,2056.598,4525.60889,2724.840,
3447.12842,2056.598,4525.70020,2725.840,
3447.21997,2056.598,4525.79199,2725.840,
3447.31152,2056.598,4525.88330,2725.840,
3447.40308,2057.598,4525.97510,2725.840,
3447.49463,2057.598,4526.06641,2725.840,
3447.58594,2057.598,4526.15771,2725.840,
3447.67749,2058.598,4526.24951,2726.840,
3447.76904,2058.598,4526.34082,2726.840,
3447.86060,2058.598,4526.43262,2726.840,
3447.95215,2059.598,4526.52393,2726.840,
3448.04370,2059.598,4526.61572,2726.840,
3448.13525,2059.598,4526.70703,2726.840,
3448.22681,2059.598,4526.79834,2727.840,
3448.31812,2060.598,4526.89014,2727.840,
3448.40967,2059.598,4526.98145,2727.840,
3448.50122,2060.598,4527.07324,2727.840,
3448.59277,2060.598,4527.16455,2728.840,
3448.68433,2060.598,4527.25635,2727.840,
3448.77588,2060.598,4527.34766,2728.840,
3448.86743,2061.598,4527.43896,2728.840,
3448.95898,2061.598,4527.53076,2729.840,
3449.05029,2061.598,4527.62207,2728.840,
3449.14185,2062.598,4527.71387,2728.840,
3449.23340,2061.598,4527.80518,2729.840,
3449.32495,2062.598,4527.89697,2728.840,
3449.41650,2063.598,4527.98828,2729.840,
3449.50806,2063.598,4528.08008,2729.840,
3449.59961,2062.598,4528.17139,2729.840,
3449.69092,2063.598,4528.26270,2729.840,
3449.78247,2063.598,4528.35449,2729.840,
3449.87402,2063.598,4528.44580,2730.840,
3449.96558,2064.598,4528.53760,2730.840,
3450.05713,2064.598,4528.62891,2731.840,
3450.14868,2064.598,4528.72070,2730.840,
3450.24023,2064.598,4528.81201,2731.840,
3450.33179,2065.598,4528.90332,2731.840,
3450.42310,2065.598,4528.99512,2731.840,
3450.51465,2065.598,4529.08643,2731.840,
3450.60620,2066.598,4529.17822,2731.840,
3450.69775,2066.598,4529.26953,2731.840,
3450.78931,2066.598,4529.36133,2732.840,
3450.88086,2067.598,4529.45264,2732.840,
3450.97241,2067.598,4529.54395,2732.840,
3451.06372,2067.598,4529.63574,2732.840,
3451.15527,2067.598,4529.72705,2732.840,
3451.24683,2067.598,4529.81885,2733.840,
3451.33838,2067.598,4529.91016,2733.840,
3451.42993,2068.598,4530.00195,2733.840,
3451.52148,2069.598,4530.09326,2734.840,
3451.61304,2069.598,4530.18506,2733.840,
3451.70459,2069.598,4530.27637,2733.840,
3451.79590,2069.598,4530.36768,2734.840,
3451.88745,2069.598,4530.45947,2733.840,
3451.97900,2069.598,4530.55078,2733.840,
3452.07056,2070.598,4530.64258,2734.840,
3452.16211,2070.598,4530.73389,2734.840,
3452.25366,2070.598,4530.82568,2734.840,
3452.34521,2071.598,4530.91699,2734.840,
3452.43677,2070.598,4531.00830,2735.840,
3452.52808,2071.598,4531.10010,2735.840,
3452.61963,2071.598,4531.19141,2735.840,
3452.71118,2071.598,4531.28320,2735.840,
3452.80273,2071.598,4531.37451,2735.840,
3452.89429,2072.598,4531.46631,2735.840,
3452.98584,2072.598,4531.55762,2735.840,
3453.07739,2072.598,4531.64893,2735.840,
3453.16870,2072.598,4531.74072,2736.840,
3453.26025,2073.598,4531.83203,2736.840,
3453.35181,2073.598,4531.92383,2736.840,
3453.44336,2073.598,4532.01514,2736.840,
3453.53491,2073.598,4532.10693,2736.840,
3453.62646,2074.598,4532.19824,2736.840,
3453.71802,2074.598,4532.29004,2736.840,
3453.80957,2074.598,4532.38135,2737.840,
3453.90088,2075.598,4532.47266,2737.840,
3453.99243,2075.598,4532.56445,2737.840,
3454.08398,2075.598,4532.65576,2737.840,
3454.17554,2075.598,4532.74756,2737.840,
3454.26709,2075.598,4532.83887,2738.840,
3454.35864,2076.598,4532.93066,2737.840,
3454.45020,2076.598,4533.02197,2738.840,
3454.54175,2077.598,4533.11328,2738.840,
3454.63306,2077.598,4533.20508,2739.840,
3454.72461,2077.598,4533.29639,2738.840,
3454.81616,2077.598,4533.38818,2738.840,
3454.90771,2077.598,4533.47949,2739.840,
3454.99927,2078.598,4533.57129,2739.840,
3455.09082,2078.598,4533.66260,2739.840,
3455.18237,2078.598,4533.75391,2740.840,
3455.27368,2079.598,4533.84570,2739.840,
3455.36523,2079.598,4533.93701,2740.840,
3455.45679,2080.598,4534.02881,2739.840,
3455.54834,2079.598,4534.12012,2741.840,
3455.63989,2079.598,4534.21191,2740.840,
3455.73145,2080.598,4534.30322,2740.840,
3455.82300,2080.598,4534.39453,2740.840,
3455.91455,2080.598,4534.48633,2741.840,
3456.00586,2081.598,4534.57764,2741.840,
3456.09741,2080.598,4534.66943,2741.840,
3456.18896,2081.598,4534.76074,2741.840,
3456.28052,2081.598,4534.85254,2741.840,
3456.37207,2081.598,4534.94385,2742.840,
3456.46362,2081.598,4535.03564,2742.840,
3456.55518,2081.598,4535.12695,2742.840,
3456.64673,2082.598,4535.21826,2742.840,
3456.73804,2082.598,4535.31006,2742.840,
3456.82959,2082.598,4535.40137,2742.840,
3456.92114,2083.598,4535.49316,2742.840,
3457.01270,2083.598,4535.58447,2743.840,
3457.10425,2083.598,4535.67627,2742.840,
3457.19580,2084.598,4535.76758,2743.840,
3457.28735,2083.598,4535.85889,2743.840,
3457.37866,2084.598,4535.95068,2743.840,
3457.47021,2084.598,4536.04199,2743.840,
3457.56177,2085.598,4536.13379,2743.840,
3457.65332,2084.598,4536.22510,2744.840,
3457.74487,2085.598,4536.31689,2744.840,
3457.83643,2085.598,4536.40820,2744.840,
3457.92798,2085.598,4536.49951,2744.840,
3458.01953,2086.598,4536.59131,2744.840,
3458.11084,2086.598,4536.68262,2744.840,
3458.20239,2087.598,4536.77441,2745.840,
3458.29395,2086.598,4536.86572,2744.840,
3458.38550,2087.598,4536.95752,2745.840,
3458.47705,2087.598,4537.04883,2745.840,
3458.56860,2087.598,4537.14063,2745.840,
3458.66016,2088.598,4537.23193,2745.840,
3458.75146,2088.598,4537.32324,2745.840,
3458.84302,2088.598,4537.41504,2746.840,
3458.93457,2088.598,4537.50635,2746.840,
3459.02612,2088.598,4537.59814,2746.840,
3459.11768,2088.598,4537.68945,2746.840,
3459.20923,2089.598,4537.78125,2746.840,
3459.30078,2089.598,4537.87256,2746.840,
3459.39233,2089.598,4537.96387,2746.840,
3459.48364,2089.598,4538.05566,2747.840,
3459.57520,2089.598,4538.14697,2747.840,
3459.66675,2090.598,4538.23877,2747.840,
3459.75830,2090.598,4538.33008,2746.840,
3459.84985,2090.598,4538.42188,2747.840,
3459.94141,2090.598,4538.51318,2747.840,
3460.03296,2091.598,4538.60449,2747.840,
3460.12451,2091.598,4538.69629,2747.840,
3460.21582,2091.598,4538.78760,2747.840,
3460.30737,2092.598,4538.87939,2748.840,
3460.39893,2092.598,4538.97070,2748.840,
3460.49048,2092.598,4539.06250,2748.840,
3460.58203,2092.598,4539.15381,2748.840,
3460.67358,2092.598,4539.24561,2749.840,
3460.76514,2093.598,4539.33691,2749.840,
3460.85645,2093.598,4539.42822,2749.840,
3460.94800,2093.598,4539.52002,2749.840,
3461.03955,2093.598,4539.61133,2749.840,
3461.13110,2094.598,4539.70313,2749.840,
3461.22266,2095.598,4539.79443,2750.840,
3461.31421,2095.598,4539.88623,2749.840,
3461.40576,2096.598,4539.97754,2750.840,
3461.49731,2097.598,4540.06885,2750.840,
3461.58862,2098.598,4540.16064,2750.840,
3461.68018,2099.598,4540.25195,2751.840,
3461.77173,2099.598,4540.34375,2752.840,
3461.86328,2099.598,4540.43506,2751.840,
3461.95483,2100.598,4540.52686,2752.840,
3462.04639,2100.598,4540.61816,2752.840,
3462.13794,2100.598,4540.70947,2753.840,
3462.22949,2101.598,4540.80127,2752.840,
3462.32080,2101.598,4540.89258,2752.840,
3462.41235,2100.598,4540.98438,2752.840,
3462.50391,2100.598,4541.07568,2752.840,
3462.59546,2101.598,4541.16748,2752.840,
3462.68701,2100.598,4541.25879,2752.840,
3462.77856,2100.598,4541.35059,2752.840,
3462.87012,2101.598,4541.44189,2752.840,
3462.96143,2101.598,4541.53320,2753.840,
3463.05298,2100.598,4541.62500,2753.840,
3463.14453,2101.598,4541.71631,2753.840,
3463.23608,2101.598,4541.80811,2754.840,
3463.32764,2100.598,4541.89941,2753.840,
3463.41919,2101.598,4541.99121,2754.840,
3463.51074,2101.598,4542.08252,2753.840,
3463.60229,2101.598,4542.17383,2754.840,
3463.69360,2100.598,4542.26563,2754.840,
3463.78516,2099.598,4542.35693,2754.840,
3463.87671,2099.598,4542.44873,2754.840,
3463.96826,2098.598,4542.54004,2755.840,
3464.05981,2099.598,4542.63184,2755.840,
3464.15137,2098.598,4542.72314,2755.840,
3464.24292,2098.598,4542.81445,2754.840,
3464.33423,2099.598,4542.90625,2755.840,
3464.42578,2099.598,4542.99756,2755.840,
3464.51733,2099.598,4543.08936,2755.840,
3464.60889,2100.598,4543.18066,2755.840,
3464.70044,2100.598,4543.27246,2757.840,
3464.79199,2101.598,4543.36377,2756.840,
3464.88354,2101.598,4543.45557,2756.840,
3464.97510,2102.598,4543.54688,2756.840,
3465.06641,2103.598,4543.63818,2756.840,
3465.15796,2103.598,4543.72998,2756.840,
3465.24951,2103.598,4543.82129,2757.840,
3465.34106,2104.598,4543.91309,2757.840,
3465.43262,2104.598,4544.00439,2756.840,
3465.52417,2105.598,4544.09619,2757.840,
3465.61572,2106.598,4544.18750,2757.840,
3465.70728,2106.598,4544.27881,2757.840,
3465.79858,2106.598,4544.37061,2757.840,
3465.89014,2106.598,4544.46191,2757.840,
3465.98169,2107.598,4544.55371,2757.840,
3466.07324,2107.598,4544.64502,2757.840,
3466.16479,2108.598,4544.73682,2758.840,
3466.25635,2108.598,4544.82813,2758.840,
3466.34790,2108.598,4544.91943,2758.840,
3466.43921,2108.598,4545.01123,2759.840,
3466.53076,2109.598,4545.10254,2759.840,
3466.62231,2108.598,4545.19434,2759.840,
3466.71387,2109.598,4545.28564,2759.840,
3466.80542,2109.598,4545.37744,2759.840,
3466.89697,2109.598,4545.46875,2759.840,
3466.98853,2110.598,4545.56006,2760.840,
3467.08008,2110.598,4545.65186,2760.840,
3467.17139,2110.598,4545.74316,2760.840,
3467.26294,2110.598,4545.83496,2760.840,
3467.35449,2111.598,4545.92627,2760.840,
3467.44604,2111.598,4546.01807,2760.840,
3467.53760,2112.598,4546.10938,2761.840,
3467.62915,2111.598,4546.20117,2761.840,
3467.72070,2112.598,4546.29248,2761.840,
3467.81226,2112.598,4546.38379,2761.840,
3467.90356,2112.598,4546.47559,2761.840,
3467.99512,2113.598,4546.56689,2761.840,
3468.08667,2112.598,4546.65869,2761.840,
3468.17822,2113.598,4546.75000,2761.840,
3468.26978,2114.598,4546.84180,2762.840,
3468.36133,2114.598,4546.93311,2762.840,
3468.45288,2114.598,4547.02441,2762.840,
3468.54419,2114.598,4547.11621,2762.840,
3468.63574,2115.598,4547.20752,2762.840,
3468.72729,2114.598,4547.29932,2762.840,
3468.81885,2115.598,4547.39063,2763.840,
3468.91040,2115.598,4547.48242,2763.840,
3469.00195,2115.598,4547.57373,2763.840,
3469.09351,2115.598,4547.66504,2763.840,
3469.18506,2116.598,4547.75684,2763.840,
3469.27637,2116.598,4547.84814,2763.840,
3469.36792,2116.598,4547.93994,2764.840,
3469.45947,2117.598,4548.03125,2763.840,
3469.55103,2117.598,4548.12305,2765.840,
3469.64258,2117.598,4548.21436,2764.840,
3469.73413,2118.598,4548.30615,2764.840,
3469.82568,2117.598,4548.39746,2764.840,
3469.91699,2118.598,4548.48877,2764.840,
3470.00854,2119.598,4548.58057,2764.840,
3470.10010,2118.598,4548.67188,2765.840,
3470.19165,2119.598,4548.76367,2765.840,
3470.28320,2119.598,4548.85498,2765.840,
3470.37476,2119.598,4548.94678,2765.840,
3470.46631,2119.598,4549.03809,2765.840,
3470.55786,2120.598,4549.12939,2766.840,
3470.64917,2120.598,4549.22119,2765.840,
3470.74072,2120.598,4549.31250,2766.840,
3470.83228,2120.598,4549.40430,2766.840,
3470.92383,2121.598,4549.49561,2766.840,
3471.01538,2121.598,4549.58740,2766.840,
3471.10693,2121.598,4549.67871,2766.840,
3471.19849,2121.598,4549.77002,2767.840,
3471.29004,2121.598,4549.86182,2767.840,
3471.38135,2122.598,4549.95313,2767.840,
3471.47290,2122.598,4550.04492,2767.840,
3471.56445,2122.598,4550.13623,2767.840,
3471.65601,2123.598,4550.22803,2767.840,
3471.74756,2123.598,4550.31934,2767.840,
3471.83911,2123.598,4550.41113,2767.840,
3471.93066,2124.598,4550.50244,2767.840,
3472.02197,2124.598,4550.59375,2768.840,
3472.11353,2124.598,4550.68555,2768.840,
3472.20508,2124.598,4550.77686,2768.840,
3472.29663,2124.598,4550.86865,2768.840,
3472.38818,2125.598,4550.95996,2768.840,
3472.47974,2125.598,4551.05176,2768.840,
3472.57129,2125.598,4551.14307,2768.840,
3472.66284,2125.598,4551.23438,2769.840,
3472.75415,2126.598,4551.32617,2769.840,
3472.84570,2126.598,4551.41748,2769.840,
3472.93726,2126.598,4551.50928,2769.840,
3473.02881,2127.598,4551.60059,2769.840,
3473.12036,2127.598,4551.69238,2769.840,
3473.21191,2127.598,4551.78369,2769.840,
3473.30347,2127.598,4551.87500,2770.840,
3473.39502,2127.598,4551.96680,2769.840,
3473.48633,2128.598,4552.05811,2770.840,
3473.57788,2128.598,4552.14990,2770.840,
3473.66943,2128.598,4552.24121,2770.840,
3473.76099,2128.598,4552.33301,2771.840,
3473.85254,2129.598,4552.42432,2770.840,
3473.94409,2129.598,4552.51611,2771.840,
3474.03564,2129.598,4552.60742,2771.840,
3474.12695,2129.598,4552.69873,2771.840,
3474.21851,2130.598,4552.79053,2771.840,
3474.31006,2131.598,4552.88184,2772.840,
3474.40161,2130.598,4552.97363,2772.840,
3474.49316,2130.598,4553.06494,2772.840,
3474.58472,2131.598,4553.15674,2772.840,
3474.67627,2131.598,4553.24805,2772.840,
3474.76782,2131.598,4553.33936,2772.840,
3474.85913,2131.598,4553.43115,2772.840,
3474.95068,2131.598,4553.52246,2773.840,
3475.04224,2131.598,4553.61426,2772.840,
3475.13379,2132.598,4553.70557,2773.840,
3475.22534,2132.598,4553.79736,2773.840,
3475.31689,2132.598,4553.88867,2773.840,
3475.40845,2132.598,4553.97998,2773.840,
3475.50000,2133.598,4554.07178,2773.840,
3475.59131,2133.598,4554.16309,2774.840,
3475.68286,2133.598,4554.25488,2774.840,
3475.77441,2135.598,4554.34619,2773.840,
3475.86597,2134.598,4554.43799,2774.840,
3475.95752,2134.598,4554.52930,2774.840,
3476.04907,2135.598,4554.62109,2774.840,
3476.14063,2135.598,4554.71240,2774.840,
3476.23193,2135.598,4554.80371,2774.840,
3476.32349,2136.598,4554.89551,2774.840,
3476.41504,2136.598,4554.98682,2775.840,
3476.50659,2136.598,4555.07861,2775.840,
3476.59814,2135.598,4555.16992,2775.840,
3476.68970,2136.598,4555.26172,2775.840,
3476.78125,2136.598,4555.35303,2775.840,
3476.87280,2136.598,4555.44434,2775.840,
3476.96411,2137.598,4555.53613,2776.840,
3477.05566,2137.598,4555.62744,2776.840,
3477.14722,2137.598,4555.71924,2776.840,
3477.23877,2137.598,4555.81055,2776.840,
3477.33032,2137.598,4555.90234,2776.840,
3477.42188,2138.598,4555.99365,2776.840,
3477.51343,2138.598,4556.08496,2776.840,
3477.60474,2138.598,4556.17676,2777.840,
3477.69629,2138.598,4556.26807,2777.840,
3477.78784,2139.598,4556.35986,2777.840,
3477.87939,2139.598,4556.45117,2778.840,
3477.97095,2139.598,4556.54297,2778.840,
3478.06250,2140.598,4556.63428,2778.840,
3478.15405,2140.598,4556.72607,2777.840,
3478.24561,2140.598,4556.81738,2778.840,
3478.33691,2140.598,4556.90869,2778.840,
3478.42847,2140.598,4557.00049,2778.840,
3478.52002,2140.598,4557.09180,2778.840,
3478.61157,2141.598,4557.18359,2779.840,
3478.70313,2142.598,4557.27490,2778.840,
3478.79468,2141.598,4557.36670,2777.840,
3478.88623,2142.598,4557.45801,2779.840,
3478.97778,2142.598,4557.54932,2778.840,
3479.06909,2143.598,4557.64111,2778.840,
3479.16064,2142.598,4557.73242,2779.840,
3479.25220,2143.598,4557.82422,2779.840,
3479.34375,2143.598,4557.91553,2780.840,
3479.43530,2143.598,4558.00732,2779.840,
3479.52686,2143.598,4558.09863,2780.840,
3479.61841,2144.598,4558.18994,2780.840,
3479.70972,2144.598,4558.28174,2780.840,
3479.80127,2144.598,4558.37305,2780.840,
3479.89282,2144.598,4558.46484,2780.840,
3479.98438,2144.598,4558.55615,2780.840,
3480.07593,2145.598,4558.64795,2780.840,
3480.16748,2146.598,4558.73926,2780.840,
3480.25903,2145.598,4558.83057,2780.840,
3480.35059,2146.598,4558.92236,2781.840,
3480.44189,2146.598,4559.01367,2781.840,
3480.53345,2145.598,4559.10547,2781.840,
3480.62500,2146.598,4559.19678,2781.840,
3480.71655,2146.598,4559.28857,2781.840,
3480.80811,2146.598,4559.37988,2782.840,
3480.89966,2145.598,4559.47168,2782.840,
3480.99121,2145.598,4559.56299,2782.840,
3481.08276,2145.598,4559.65430,2782.840,
3481.17407,2146.598,4559.74609,2782.840,
3481.26563,2146.598,4559.83740,2782.840,
3481.35718,2146.598,4559.92920,2783.840,
3481.44873,2147.598,4560.02051,2783.840,
3481.54028,2148.598,4560.11230,2782.840,
3481.63184,2148.598,4560.20361,2783.840,
3481.72339,2149.598,4560.29492,2783.840,
3481.81470,2149.598,4560.38672,2782.840,
3481.90625,2149.598,4560.47803,2783.840,
3481.99780,2149.598,4560.56982,2782.840,
3482.08936,2150.598,4560.66113,2782.840,
3482.18091,2150.598,4560.75293,2782.840,
3482.27246,2151.598,4560.84424,2783.840,
3482.36401,2151.598,4560.93555,2782.840,
3482.45557,2151.598,4561.02734,2783.840,
3482.54688,2152.598,4561.11865,2783.840,
3482.63843,2152.598,4561.21045,2783.840,
3482.72998,2153.598,4561.30176,2783.840,
3482.82153,2154.598,4561.39355,2783.840,
3482.91309,2155.598,4561.48486,2783.840,
3483.00464,2156.598,4561.57666,2784.840,
3483.09619,2157.598,4561.66797,2784.840,
3483.18750,2157.598,4561.75928,2784.840,
3483.27905,2157.598,4561.85107,2784.840,
3483.37061,2157.598,4561.94238,2785.840,
3483.46216,2157.598,4562.03418,2785.840,
3483.55371,2157.598,4562.12549,2785.840,
3483.64526,2157.598,4562.21729,2786.840,
3483.73682,2157.598,4562.30859,2786.840,
3483.82837,2157.598,4562.39990,2785.840,
3483.91968,2156.598,4562.49170,2786.840,
3484.01123,2157.598,4562.58301,2786.840,
3484.10278,2157.598,4562.67480,2786.840,
3484.19434,2157.598,4562.76611,2786.840,
3484.28589,2157.598,4562.85791,2786.840,
3484.37744,2157.598,4562.94922,2787.840,
3484.46899,2157.598,4563.04053,2787.840,
3484.56055,2158.598,4563.13232,2786.840,
3484.65186,2157.598,4563.22363,2786.840,
3484.74341,2158.598,4563.31543,2787.840,
3484.83496,2157.598,4563.40674,2787.840,
3484.92651,2158.598,4563.49854,2787.840,
3485.01807,2159.598,4563.58984,2787.840,
3485.10962,2158.598,4563.68164,2787.840,
3485.20117,2158.598,4563.77295,2789.840,
3485.29248,2159.598,4563.86426,2788.840,
3485.38403,2158.598,4563.95605,2788.840,
3485.47559,2160.598,4564.04736,2788.840,
3485.56714,2160.598,4564.13916,2788.840,
3485.65869,2160.598,4564.23047,2788.840,
3485.75024,2160.598,4564.32227,2788.840,
3485.84180,2160.598,4564.41357,2789.840,
3485.93335,2160.598,4564.50488,2789.840,
3486.02466,2161.598,4564.59668,2789.840,
3486.11621,2161.598,4564.68799,2789.840,
3486.20776,2161.598,4564.77979,2789.840,
3486.29932,2161.598,4564.87109,2789.840,
3486.39087,2161.598,4564.96289,2790.840,
3486.48242,2162.598,4565.05420,2790.840,
3486.57397,2162.598,4565.14551,2790.840,
3486.66553,2162.598,4565.23730,2791.840,
3486.75684,2162.598,4565.32861,2790.840,
3486.84839,2163.598,4565.42041,2791.840,
3486.93994,2163.598,4565.51172,2790.840,
3487.03149,2163.598,4565.60352,2790.840,
3487.12305,2163.598,4565.69482,2791.840,
3487.21460,2164.598,4565.78662,2790.840,
3487.30615,2164.598,4565.87793,2791.840,
3487.39746,2164.598,4565.96924,2791.840,
3487.48901,2165.598,4566.06104,2791.840,
3487.58057,2165.598,4566.15234,2791.840,
3487.67212,2165.598,4566.24414,2791.840,
3487.76367,2166.598,4566.33545,2791.840,
3487.85522,2165.598,4566.42725,2792.840,
3487.94678,2165.598,4566.51855,2791.840,
3488.03833,2166.598,4566.60986,2791.840,
3488.12964,2166.598,4566.70166,2792.840,
3488.22119,2167.598,4566.79297,2792.840,
3488.31274,2167.598,4566.88477,2793.840,
3488.40430,2167.598,4566.97607,2792.840,
3488.49585,2167.598,4567.06787,2793.840,
3488.58740,2168.598,4567.15918,2792.840,
3488.67896,2167.598,4567.25049,2793.840,
3488.77026,2168.598,4567.34229,2793.840,
3488.86182,2168.598,4567.43359,2793.840,
3488.95337,2169.598,4567.52539,2793.840,
3489.04492,2168.598,4567.61670,2793.840,
3489.13647,2169.598,4567.70850,2793.840,
3489.22803,2169.598,4567.79980,2793.840,
3489.31958,2170.598,4567.89160,2793.840,
3489.41113,2170.598,4567.98291,2793.840,
3489.50244,2170.598,4568.07422,2793.840,
3489.59399,2170.598,4568.16602,2795.840,
3489.68555,2171.598,4568.25732,2793.840,
3489.77710,2171.598,4568.34912,2794.840,
3489.86865,2171.598,4568.44043,2794.840,
3489.96021,2171.598,4568.53223,2794.840,
3490.05176,2171.598,4568.62354,2794.840,
3490.14331,2172.598,4568.71484,2795.840,
3490.23462,2172.598,4568.80664,2795.840,
3490.32617,2172.598,4568.89795,2795.840,
3490.41772,2173.598,4568.98975,2795.840,
3490.50928,2172.598,4569.08105,2795.840,
3490.60083,2173.598,4569.17285,2795.840,
3490.69238,2173.598,4569.26416,2795.840,
3490.78394,2173.598,4569.35547,2795.840,
3490.87524,2173.598,4569.44727,2795.840,
3490.96680,2174.598,4569.53857,2796.840,
3491.05835,2174.598,4569.63037,2797.840,
3491.14990,2174.598,4569.72168,2796.840,
3491.24146,2175.598,4569.81348,2796.840,
3491.33301,2175.598,4569.90479,2797.840,
3491.42456,2175.598,4569.99658,2797.840,
3491.51611,2175.598,4570.08789,2796.840,
3491.60742,2176.598,4570.17920,2796.840,
3491.69897,2176.598,4570.27100,2796.840,
3491.79053,2177.598,4570.36230,2797.840,
3491.88208,2177.598,4570.45410,2797.840,
3491.97363,2177.598,4570.54541,2797.840,
3492.06519,2177.598,4570.63721,2797.840,
3492.15674,2178.598,4570.72852,2797.840,
3492.24829,2178.598,4570.81982,2797.840,
3492.33960,2178.598,4570.91162,2797.840,
3492.43115,2178.598,4571.00293,2798.840,
3492.52271,2179.598,4571.09473,2798.840,
3492.61426,2179.598,4571.18604,2798.840,
3492.70581,2179.598,4571.27783,2798.840,
3492.79736,2179.598,4571.36914,2799.840,
3492.88892,2179.598,4571.46045,2798.840,
3492.98022,2179.598,4571.55225,2798.840,
3493.07178,2180.598,4571.64355,2799.840,
3493.16333,2181.598,4571.73535,2799.840,
3493.25488,2180.598,4571.82666,2799.840,
3493.34644,2182.598,4571.91846,2799.840,
3493.43799,2181.598,4572.00977,2799.840,
3493.52954,2181.598,4572.10107,2799.840,
3493.62109,2182.598,4572.19287,2799.840,
3493.71240,2182.598,4572.28418,2799.840,
3493.80396,2182.598,4572.37598,2799.840,
3493.89551,2182.598,4572.46729,2799.840,
3493.98706,2182.598,4572.55908,2800.840,
3494.07861,2183.598,4572.65039,2800.840,
3494.17017,2183.598,4572.74219,2800.840,
3494.26172,2183.598,4572.83350,2800.840,
3494.35327,2183.598,4572.92480,2800.840,
3494.44458,2183.598,4573.01660,2800.840,
3494.53613,2183.598,4573.10791,2800.840,
3494.62769,2184.598,4573.19971,2800.840,
3494.71924,2184.598,4573.29102,2800.840,
3494.81079,2185.598,4573.38281,2801.840,
3494.90234,2185.598,4573.47412,2802.840,
3494.99390,2185.598,4573.56543,2801.840,
3495.08521,2185.598,4573.65723,2801.840,
3495.17676,2185.598,4573.74854,2802.840,
3495.26831,2186.598,4573.84033,2801.840,
3495.35986,2186.598,4573.93164,2801.840,
3495.45142,2186.598,4574.02344,2802.840,
3495.54297,2186.598,4574.11475,2802.840,
3495.63452,2186.598,4574.20605,2802.840,
3495.72607,2187.598,4574.29785,2802.840,
3495.81738,2187.598,4574.38916,2802.840,
3495.90894,2187.598,4574.48096,2802.840,
3496.00049,2188.598,4574.57227,2802.840,
3496.09204,2188.598,4574.66406,2802.840,
3496.18359,2188.598,4574.75537,2803.840,
3496.27515,2188.598,4574.84717,2803.840,
3496.36670,2189.598,4574.93848,2803.840,
3496.45801,2189.598,4575.02979,2803.840,
3496.54956,2189.598,4575.12158,2803.840,
3496.64111,2190.598,4575.21289,2803.840,
3496.73267,2190.598,4575.30469,2803.840,
3496.82422,2190.598,4575.39600,2803.840,
3496.91577,2190.598,4575.48779,2804.840,
3497.00732,2191.598,4575.57910,2804.840,
3497.09888,2190.598,4575.67041,2804.840,
3497.19019,2191.598,4575.76221,2804.840,
3497.28174,2191.598,4575.85352,2804.840,
3497.37329,2191.598,4575.94531,2804.840,
3497.46484,2191.598,4576.03662,2804.840,
3497.55640,2191.598,4576.12842,2804.840,
3497.64795,2192.598,4576.21973,2805.840,
3497.73950,2192.598,4576.31104,2804.840,
3497.83105,2193.598,4576.40283,2805.840,
3497.92236,2192.598,4576.49414,2805.840,
3498.01392,2193.598,4576.58594,2805.840,
3498.10547,2193.598,4576.67725,2805.840,
3498.19702,2193.598,4576.76904,2805.840,
3498.28857,2194.598,4576.86035,2805.840,
3498.38013,2194.598,4576.95215,2806.840,
3498.47168,2194.598,4577.04346,2806.840,
3498.56299,2194.598,4577.13477,2805.840,
3498.65454,2195.598,4577.22656,2806.840,
3498.74609,2195.598,4577.31787,2806.840,
3498.83765,2195.598,4577.40967,2806.840,
3498.92920,2195.598,4577.50098,2806.840,
3499.02075,2196.598,4577.59277,2806.840,
3499.11230,2196.598,4577.68408,2807.840,
3499.20386,2196.598,4577.77539,2806.840,
3499.29517,2197.598,4577.86719,2807.840,
3499.38672,2197.598,4577.95850,2807.840,
3499.47827,2197.598,4578.05029,2807.840,
3499.56982,2197.598,4578.14160,2807.840,
3499.66138,2198.598,4578.23340,2807.840,
3499.75293,2198.598,4578.32471,2807.840,
3499.84448,2197.598,4578.41602,2808.840,
3499.93604,2198.598,4578.50781,2807.840,
3500.02734,2197.598,4578.59912,2807.840,
3500.11890,2197.598,4578.69092,2808.840,
3500.21045,2198.598,4578.78223,2808.840,
3500.30200,2198.598,4578.87402,2808.840,
3500.39355,2198.598,4578.96533,2808.840,
3500.48511,2198.598,4579.05713,2808.840,
3500.57666,2198.598,4579.14844,2808.840,
3500.66797,2199.598,4579.23975,2808.840,
3500.75952,2199.598,4579.33154,2808.840,
3500.85107,2199.598,4579.42285,2808.840,
3500.94263,2200.598,4579.51465,2808.840,
3501.03418,2200.598,4579.60596,2808.840,
3501.12573,2200.598,4579.69775,2809.840,
3501.21729,2201.598,4579.78906,2809.840,
3501.30884,2201.598,4579.88037,2809.840,
3501.40015,2201.598,4579.97217,2809.840,
3501.49170,2201.598,4580.06348,2809.840,
3501.58325,2202.598,4580.15527,2809.840,
3501.67480,2202.598,4580.24658,2809.840,
3501.76636,2203.598,4580.33838,2809.840,
3501.85791,2203.598,4580.42969,2810.840,
3501.94946,2203.598,4580.52100,2810.840,
3502.04077,2203.598,4580.61279,2810.840,
3502.13232,2205.598,4580.70410,2810.840,
3502.22388,2204.598,4580.79590,2810.840,
3502.31543,2205.598,4580.88721,2810.840,
3502.40698,2206.598,4580.97900,2810.840,
3502.49854,2206.598,4581.07031,2810.840,
3502.59009,2206.598,4581.16211,2810.840,
3502.68164,2207.598,4581.25342,2811.840,
3502.77295,2207.598,4581.34473,2811.840,
3502.86450,2206.598,4581.43652,2811.840,
3502.95605,2206.598,4581.52783,2811.840,
3503.04761,2206.598,4581.61963,2811.840,
3503.13916,2206.598,4581.71094,2812.840,
3503.23071,2207.598,4581.80273,2811.840,
3503.32227,2207.598,4581.89404,2812.840,
3503.41382,2207.598,4581.98535,2812.840,
3503.50513,2207.598,4582.07715,2812.840,
3503.59668,2208.598,4582.16846,2812.840,
3503.68823,2208.598,4582.26025,2812.840,
3503.77979,2208.598,4582.35156,2812.840,
3503.87134,2208.598,4582.44336,2813.840,
3503.96289,2208.598,4582.53467,2812.840,
3504.05444,2209.598,4582.62598,2813.840,
3504.14575,2209.598,4582.71777,2813.840,
3504.23730,2209.598,4582.80908,2813.840,
3504.32886,2209.598,4582.90088,2813.840,
3504.42041,2209.598,4582.99219,2813.840,
3504.51196,2210.598,4583.08398,2813.840,
3504.60352,2210.598,4583.17529,2813.840,
3504.69507,2210.598,4583.26660,2813.840,
3504.78662,2210.598,4583.35840,2813.840,
3504.87793,2211.598,4583.44971,2813.840,
3504.96948,2211.598,4583.54150,2814.840,
3505.06104,2212.598,4583.63281,2814.840,
3505.15259,2212.598,4583.72461,2814.840,
3505.24414,2212.598,4583.81592,2813.840,
3505.33569,2212.598,4583.90771,2814.840,
3505.42725,2213.598,4583.99902,2814.840,
3505.51880,2212.598,4584.09033,2814.840,
3505.61011,2213.598,4584.18213,2814.840,
3505.70166,2213.598,4584.27344,2815.840,
3505.79321,2213.598,4584.36523,2815.840,
3505.88477,2213.598,4584.45654,2815.840,
3505.97632,2214.598,4584.54834,2815.840,
3506.06787,2213.598,4584.63965,2815.840,
3506.15942,2214.598,4584.73096,2815.840,
3506.25073,2215.598,4584.82275,2815.840,
3506.34229,2215.598,4584.91406,2815.840,
3506.43384,2215.598,4585.00586,2816.840,
3506.52539,2216.598,4585.09717,2816.840,
3506.61694,2215.598,4585.18896,2815.840,
3506.70850,2216.598,4585.28027,2816.840,
3506.80005,2216.598,4585.37158,2816.840,
3506.89160,2216.598,4585.46338,2816.840,
3506.98291,2216.598,4585.55469,2817.840,
3507.07446,2216.598,4585.64648,2816.840,
3507.16602,2217.598,4585.73779,2817.840,
3507.25757,2217.598,4585.82959,2816.840,
3507.34912,2217.598,4585.92090,2816.840,
3507.44067,2218.598,4586.01270,2816.840,
3507.53223,2217.598,4586.10400,2816.840,
3507.62354,2218.598,4586.19531,2817.840,
3507.71509,2218.598,4586.28711,2817.840,
3507.80664,2218.598,4586.37842,2817.840,
3507.89819,2219.598,4586.47021,2817.840,
3507.98975,2219.598,4586.56152,2817.840,
3508.08130,2219.598,4586.65332,2817.840,
3508.17285,2219.598,4586.74463,2817.840,
3508.26440,2219.598,4586.83594,2818.840,
3508.35571,2220.598,4586.92773,2817.840,
3508.44727,2220.598,4587.01904,2817.840,
3508.53882,2220.598,4587.11084,2818.840,
3508.63037,2221.598,4587.20215,2819.840,
3508.72192,2221.598,4587.29395,2818.840,
3508.81348,2221.598,4587.38525,2819.840,
3508.90503,2222.598,4587.47656,2819.840,
3508.99658,2222.598,4587.56836,2818.840,
3509.08789,2222.598,4587.65967,2819.840,
3509.17944,2222.598,4587.75146,2819.840,
3509.27100,2223.598,4587.84277,2818.840,
3509.36255,2222.598,4587.93457,2819.840,
3509.45410,2224.598,4588.02588,2819.840,
3509.54565,2223.598,4588.11768,2819.840,
3509.63721,2223.598,4588.20898,2819.840,
3509.72852,2223.598,4588.30029,2819.840,
3509.82007,2224.598,4588.39209,2819.840,
3509.91162,2224.598,4588.48340,2819.840,
3510.00317,2224.598,4588.57520,2819.840,
3510.09473,2225.598,4588.66650,2820.840,
3510.18628,2224.598,4588.75830,2820.840,
3510.27783,2225.598,4588.84961,2820.840,
3510.36938,2225.598,4588.94092,2820.840,
3510.46069,2225.598,4589.03271,2820.840,
3510.55225,2226.598,4589.12402,2820.840,
3510.64380,2226.598,4589.21582,2820.840,
3510.73535,2226.598,4589.30713,2820.840,
3510.82690,2227.598,4589.39893,2821.840,
3510.91846,2227.598,4589.49023,2821.840,
3511.01001,2227.598,4589.58154,2821.840,
3511.10156,2227.598,4589.67334,2821.840,
3511.19287,2227.598,4589.76465,2821.840,
3511.28442,2228.598,4589.85645,2821.840,
3511.37598,2228.598,4589.94775,2821.840,
3511.46753,2228.598,4590.03955,2821.840,
3511.55908,2229.598,4590.13086,2822.840,
3511.65063,2229.598,4590.22266,2822.840,
3511.74219,2229.598,4590.31396,2822.840,
3511.83350,2229.598,4590.40527,2821.840,
3511.92505,2229.598,4590.49707,2822.840,
3512.01660,2230.598,4590.58838,2822.840,
3512.10815,2230.598,4590.68018,2822.840,
3512.19971,2230.598,4590.77148,2822.840,
3512.29126,2230.598,4590.86328,2822.840,
3512.38281,2231.598,4590.95459,2822.840,
3512.47437,2231.598,4591.04590,2822.840,
3512.56567,2231.598,4591.13770,2823.840,
3512.65723,2231.598,4591.22900,2823.840,
3512.74878,2231.598,4591.32080,2823.840,
3512.84033,2232.598,4591.41211,2823.840,
3512.93188,2232.598,4591.50391,2823.840,
3513.02344,2232.598,4591.59521,2824.840,
3513.11499,2232.598,4591.68652,2823.840,
3513.20654,2233.598,4591.77832,2823.840,
3513.29785,2233.598,4591.86963,2824.840,
3513.38940,2233.598,4591.96143,2823.840,
3513.48096,2233.598,4592.05273,2823.840,
3513.57251,2233.598,4592.14453,2824.840,
3513.66406,2233.598,4592.23584,2824.840,
3513.75562,2234.598,4592.32764,2824.840,
3513.84717,2235.598,4592.41895,2824.840,
3513.93848,2234.598,4592.51025,2824.840,
3514.03003,2235.598,4592.60205,2825.840,
3514.12158,2235.598,4592.69336,2825.840,
3514.21313,2235.598,4592.78516,2825.840,
3514.30469,2236.598,4592.87646,2824.840,
3514.39624,2236.598,4592.96826,2825.840,
3514.48779,2236.598,4593.05957,2826.840,
3514.57935,2237.598,4593.15088,2825.840,
3514.67065,2237.598,4593.24268,2825.840,
3514.76221,2237.598,4593.33398,2825.840,
3514.85376,2237.598,4593.42578,2825.840,
3514.94531,2237.598,4593.51709,2825.840,
3515.03687,2237.598,4593.60889,2825.840,
3515.12842,2238.598,4593.70020,2825.840,
3515.21997,2238.598,4593.79150,2826.840,
3515.31128,2239.598,4593.88330,2826.840,
3515.40283,2238.598,4593.97461,2826.840,
3515.49438,2239.598,4594.06641,2826.840,
3515.58594,2239.598,4594.15771,2826.840,
3515.67749,2239.598,4594.24951,2826.840,
3515.76904,2239.598,4594.34082,2826.840,
3515.86060,2240.598,4594.43262,2826.840,
3515.95215,2239.598,4594.52393,2827.840,
3516.04346,2240.598,4594.61523,2827.840,
3516.13501,2240.598,4594.70703,2826.840,
3516.22656,2240.598,4594.79834,2826.840,
3516.31812,2241.598,4594.89014,2828.840,
3516.40967,2241.598,4594.98145,2827.840,
3516.50122,2241.598,4595.07324,2827.840,
3516.59277,2242.598,4595.16455,2828.840,
3516.68433,2242.598,4595.25586,2828.840,
3516.77563,2243.598,4595.34766,2827.840,
3516.86719,2242.598,4595.43896,2828.840,
3516.95874,2243.598,4595.53076,2827.840,
3517.05029,2243.598,4595.62207,2828.840,
3517.14185,2243.598,4595.71387,2828.840,
3517.23340,2244.598,4595.80518,2828.840,
3517.32495,2244.598,4595.89648,2828.840,
3517.41626,2244.598,4595.98828,2829.840,
3517.50781,2244.598,4596.07959,2829.840,
3517.59937,2244.598,4596.17139,2829.840,
3517.69092,2245.598,4596.26270,2828.840,
3517.78247,2245.598,4596.35449,2829.840,
3517.87402,2245.598,4596.44580,2829.840,
3517.96558,2245.598,4596.53711,2829.840,
3518.05713,2245.598,4596.62891,2828.840,
3518.14844,2246.598,4596.72021,2829.840,
3518.23999,2246.598,4596.81201,2829.840,
3518.33154,2246.598,4596.90332,2829.840,
3518.42310,2246.598,4596.99512,2830.840,
3518.51465,2247.598,4597.08643,2829.840,
3518.60620,2247.598,4597.17822,2829.840,
3518.69775,2247.598,4597.26953,2829.840,
3518.78931,2247.598,4597.36084,2829.840,
3518.88062,2248.598,4597.45264,2830.840,
3518.97217,2248.598,4597.54395,2830.840,
3519.06372,2248.598,4597.63574,2829.840,
3519.15527,2248.598,4597.72705,2830.840,
3519.24683,2248.598,4597.81885,2830.840,
3519.33838,2249.598,4597.91016,2830.840,
3519.42993,2249.598,4598.00146,2830.840,
3519.52124,2250.598,4598.09326,2830.840,
3519.61279,2250.598,4598.18457,2831.840,
3519.70435,2251.598,4598.27637,2830.840,
3519.79590,2251.598,4598.36768,2831.840,
3519.88745,2251.598,4598.45947,2831.840,
3519.97900,2251.598,4598.55078,2831.840,
3520.07056,2252.598,4598.64209,2831.840,
3520.16211,2252.598,4598.73389,2831.840,
3520.25342,2252.598,4598.82520,2831.840,
3520.34497,2252.598,4598.91699,2832.840,
3520.43652,2252.598,4599.00830,2831.840,
3520.52808,2253.598,4599.10010,2831.840,
3520.61963,2253.598,4599.19141,2831.840,
3520.71118,2253.598,4599.28320,2832.840,
3520.80273,2253.598,4599.37451,2832.840,
3520.89404,2253.598,4599.46582,2832.840,
3520.98560,2253.598,4599.55762,2832.840,
3521.07715,2254.598,4599.64893,2832.840,
3521.16870,2254.598,4599.74072,2832.840,
3521.26025,2254.598,4599.83203,2832.840,
3521.35181,2254.598,4599.92383,2832.840,
3521.44336,2255.598,4600.01514,2832.840,
3521.53491,2255.598,4600.10645,2832.840,
3521.62622,2255.598,4600.19824,2833.840,
3521.71777,2256.598,4600.28955,2833.840,
3521.80933,2256.598,4600.38135,2833.840,
3521.90088,2256.598,4600.47266,2833.840,
3521.99243,2256.598,4600.56445,2833.840,
3522.08398,2255.598,4600.65576,2833.840,
3522.17554,2256.598,4600.74707,2833.840,
3522.26709,2256.598,4600.83887,2833.840,
3522.35840,2256.598,4600.93018,2833.840,
3522.44995,2256.598,4601.02197,2833.840,
3522.54150,2256.598,4601.11328,2833.840,
3522.63306,2258.598,4601.20508,2833.840,
3522.72461,2257.598,4601.29639,2833.840,
3522.81616,2257.598,4601.38818,2834.840,
3522.90771,2258.598,4601.47949,2834.840,
3522.99902,2258.598,4601.57080,2834.840,
3523.09058,2258.598,4601.66260,2834.840,
3523.18213,2258.598,4601.75391,2834.840,
3523.27368,2258.598,4601.84570,2835.840,
3523.36523,2259.598,4601.93701,2835.840,
3523.45679,2259.598,4602.02881,2835.840,
3523.54834,2259.598,4602.12012,2835.840,
3523.63989,2259.598,4602.21143,2835.840,
3523.73120,2260.598,4602.30322,2835.840,
3523.82275,2260.598,4602.39453,2835.840,
3523.91431,2260.598,4602.48633,2835.840,
3524.00586,2260.598,4602.57764,2835.840,
3524.09741,2261.598,4602.66943,2835.840,
3524.18896,2261.598,4602.76074,2836.840,
3524.28052,2261.598,4602.85205,2836.840,
3524.37207,2262.598,4602.94385,2836.840,
3524.46338,2262.598,4603.03516,2837.840,
3524.55493,2262.598,4603.12695,2837.840,
3524.64648,2262.598,4603.21826,2837.840,
3524.73804,2263.598,4603.31006,2836.840,
3524.82959,2263.598,4603.40137,2836.840,
3524.92114,2263.598,4603.49316,2836.840,
3525.01270,2263.598,4603.58447,2836.840,
3525.10400,2264.598,4603.67578,2836.840,
3525.19556,2264.598,4603.76758,2836.840,
3525.28711,2264.598,4603.85889,2836.840,
3525.37866,2265.598,4603.95068,2836.840,
3525.47021,2264.598,4604.04199,2836.840,
3525.56177,2265.598,4604.13379,2836.840,
3525.65332,2265.598,4604.22510,2836.840,
3525.74487,2265.598,4604.31641,2837.840,
3525.83618,2265.598,4604.40820,2837.840,
3525.92773,2266.598,4604.49951,2837.840,
3526.01929,2266.598,4604.59131,2837.840,
3526.11084,2266.598,4604.68262,2837.840,
3526.20239,2266.598,4604.77441,2838.840,
3526.29395,2267.598,4604.86572,2837.840,
3526.38550,2267.598,4604.95703,2837.840,
3526.47681,2267.598,4605.04883,2837.840,
3526.56836,2268.598,4605.14014,2838.840,
3526.65991,2268.598,4605.23193,2837.840,
3526.75146,2268.598,4605.32324,2838.840,
3526.84302,2268.598,4605.41504,2838.840,
3526.93457,2268.598,4605.50635,2838.840,
3527.02612,2269.598,4605.59814,2838.840,
3527.11768,2269.598,4605.68945,2839.840,
3527.20898,2269.598,4605.78076,2839.840,
3527.30054,2269.598,4605.87256,2838.840,
3527.39209,2270.598,4605.96387,2838.840,
3527.48364,2270.598,4606.05566,2838.840,
3527.57520,2270.598,4606.14697,2839.840,
3527.66675,2270.598,4606.23877,2840.840,
3527.75830,2271.598,4606.33008,2839.840,
3527.84985,2271.598,4606.42139,2839.840,
3527.94116,2271.598,4606.51318,2839.840,
3528.03271,2272.598,4606.60449,2839.840,
3528.12427,2272.598,4606.69629,2840.840,
3528.21582,2271.598,4606.78760,2840.840,
3528.30737,2272.598,4606.87939,2840.840,
3528.39893,2272.598,4606.97070,2840.840,
3528.49048,2273.598,4607.06201,2840.840,
3528.58179,2273.598,4607.15381,2840.840,
3528.67334,2273.598,4607.24512,2840.840,
3528.76489,2273.598,4607.33691,2840.840,
3528.85645,2273.598,4607.42822,2840.840,
3528.94800,2274.598,4607.52002,2840.840,
3529.03955,2274.598,4607.61133,2840.840,
3529.13110,2274.598,4607.70264,2840.840,
3529.22266,2274.598,4607.79443,2841.840,
3529.31396,2274.598,4607.88574,2840.840,
3529.40552,2275.598,4607.97754,2841.840,
3529.49707,2275.598,4608.06885,2841.840,
3529.58862,2275.598,4608.16064,2841.840,
3529.68018,2275.598,4608.25195,2841.840,
3529.77173,2276.598,4608.34375,2841.840,
3529.86328,2276.598,4608.43506,2841.840,
3529.95483,2277.598,4608.52637,2841.840,
3530.04614,2276.598,4608.61816,2841.840,
3530.13770,2277.598,4608.70947,2841.840,
3530.22925,2277.598,4608.80127,2842.840,
3530.32080,2277.598,4608.89258,2842.840,
3530.41235,2277.598,4608.98438,2842.840,
3530.50391,2277.598,4609.07568,2842.840,
3530.59546,2278.598,4609.16699,2842.840,
3530.68677,2278.598,4609.25879,2842.840,
3530.77832,2279.598,4609.35010,2842.840,
3530.86987,2278.598,4609.44189,2842.840,
3530.96143,2279.598,4609.53320,2842.840,
3531.05298,2279.598,4609.62500,2842.840,
3531.14453,2279.598,4609.71631,2842.840,
3531.23608,2280.598,4609.80762,2842.840,
3531.32764,2280.598,4609.89941,2843.840,
3531.41895,2280.598,4609.99072,2843.840,
3531.51050,2281.598,4610.08252,2843.840,
3531.60205,2281.598,4610.17383,2843.840,
3531.69360,2281.598,4610.26563,2843.840,
3531.78516,2281.598,4610.35693,2843.840,
3531.87671,2281.598,4610.44873,2843.840,
3531.96826,2282.598,4610.54004,2843.840,
3532.05957,2281.598,4610.63135,2844.840,
3532.15112,2282.598,4610.72314,2843.840,
3532.24268,2282.598,4610.81445,2844.840,
3532.33423,2282.598,4610.90625,2844.840,
3532.42578,2283.598,4610.99756,2843.840,
3532.51733,2283.598,4611.08936,2844.840,
3532.60889,2283.598,4611.18066,2844.840,
3532.70044,2283.598,4611.27197,2844.840,
3532.79175,2284.598,4611.36377,2844.840,
3532.88330,2284.598,4611.45508,2844.840,
3532.97485,2284.598,4611.54688,2844.840,
3533.06641,2284.598,4611.63818,2844.840,
3533.15796,2284.598,4611.72998,2845.840,
3533.24951,2285.598,4611.82129,2844.840,
3533.34106,2285.598,4611.91260,2844.840,
3533.43262,2285.598,4612.00439,2844.840,
3533.52393,2285.598,4612.09570,2845.840,
3533.61548,2286.598,4612.18750,2845.840,
3533.70703,2285.598,4612.27881,2844.840,
3533.79858,2286.598,4612.37061,2845.840,
3533.89014,2286.598,4612.46191,2845.840,
3533.98169,2286.598,4612.55371,2845.840,
3534.07324,2287.598,4612.64502,2845.840,
3534.16455,2287.598,4612.73633,2845.840,
3534.25610,2287.598,4612.82813,2845.840,
3534.34766,2288.598,4612.91943,2845.840,
3534.43921,2288.598,4613.01123,2845.840,
3534.53076,2288.598,4613.10254,2845.840,
3534.62231,2288.598,4613.19434,2845.840,
3534.71387,2288.598,4613.28564,2845.840,
3534.80542,2289.598,4613.37695,2845.840,
3534.89673,2289.598,4613.46875,2845.840,
3534.98828,2289.598,4613.56006,2846.840,
3535.07983,2289.598,4613.65186,2846.840,
3535.17139,2290.598,4613.74316,2846.840,
3535.26294,2290.598,4613.83496,2846.840,
3535.35449,2290.598,4613.92627,2846.840,
3535.44604,2290.598,4614.01758,2846.840,
3535.53760,2291.598,4614.10938,2847.840,
3535.62891,2291.598,4614.20068,2847.840,
3535.72046,2291.598,4614.29248,2846.840,
3535.81201,2292.598,4614.38379,2847.840,
3535.90356,2291.598,4614.47559,2846.840,
3535.99512,2292.598,4614.56689,2847.840,
3536.08667,2292.598,4614.65869,2847.840,
3536.17822,2292.598,4614.75000,2847.840,
3536.26953,2292.598,4614.84131,2847.840,
3536.36108,2293.598,4614.93311,2847.840,
3536.45264,2292.598,4615.02441,2848.840,
3536.54419,2293.598,4615.11621,2847.840,
3536.63574,2293.598,4615.20752,2847.840,
3536.72729,2293.598,4615.29932,2847.840,
3536.81885,2294.598,4615.39063,2848.840,
3536.91040,2294.598,4615.48193,2848.840,
3537.00171,2294.598,4615.57373,2848.840,
3537.09326,2294.598,4615.66504,2847.840,
3537.18481,2295.598,4615.75684,2848.840,
3537.27637,2296.598,4615.84814,2848.840,
3537.36792,2295.598,4615.93994,2848.840,
3537.45947,2295.598,4616.03125,2848.840,
3537.55103,2295.598,4616.12256,2848.840,
3537.64258,2296.598,4616.21436,2848.840,
3537.73389,2296.598,4616.30566,2848.840,
3537.82544,2296.598,4616.39746,2848.840,
3537.91699,2297.598,4616.48877,2849.840,
3538.00854,2297.598,4616.58057,2848.840,
3538.10010,2297.598,4616.67188,2849.840,
3538.19165,2297.598,4616.76367,2849.840,
3538.28320,2297.598,4616.85498,2849.840,
3538.37451,2298.598,4616.94629,2849.840,
3538.46606,2298.598,4617.03809,2849.840,
3538.55762,2298.598,4617.12939,2849.840,
3538.64917,2298.598,4617.22119,2849.840,
3538.74072,2299.598,4617.31250,2849.840,
3538.83228,2299.598,4617.40430,2849.840,
3538.92383,2299.598,4617.49561,2849.840,
3539.01538,2299.598,4617.58691,2849.840,
3539.10669,2299.598,4617.67871,2849.840,
3539.19824,2300.598,4617.77002,2849.840,
3539.28979,2300.598,4617.86182,2850.840,
3539.38135,2300.598,4617.95313,2850.840,
3539.47290,2299.598,4618.04492,2850.840,
3539.56445,2299.598,4618.13623,2850.840,
3539.65601,2299.598,4618.22754,2850.840,
3539.74731,2299.598,4618.31934,2850.840,
3539.83887,2299.598,4618.41064,2850.840,
3539.93042,2299.598,4618.50244,2850.840,
3540.02197,2299.598,4618.59375,2850.840,
3540.11353,2299.598,4618.68555,2850.840,
3540.20508,2300.598,4618.77686,2850.840,
3540.29663,2301.598,4618.86865,2850.840,
3540.38818,2301.598,4618.95996,2851.840,
3540.47949,2301.598,4619.05127,2851.840,
3540.57104,2302.598,4619.14307,2850.840,
3540.66260,2302.598,4619.23438,2851.840,
3540.75415,2303.598,4619.32617,2851.840,
3540.84570,2304.598,4619.41748,2851.840,
3540.93726,2304.598,4619.50928,2851.840,
3541.02881,2304.598,4619.60059,2851.840,
3541.12036,2305.598,4619.69189,2851.840,
3541.21167,2305.598,4619.78369,2851.840,
3541.30322,2305.598,4619.87500,2851.840,
3541.39478,2305.598,4619.96680,2851.840,
3541.48633,2306.598,4620.05811,2851.840,
3541.57788,2305.598,4620.14990,2852.840,
3541.66943,2305.598,4620.24121,2852.840,
3541.76099,2304.598,4620.33252,2852.840,
3541.85229,2305.598,4620.42432,2852.840,
3541.94385,2304.598,4620.51563,2852.840,
3542.03540,2304.598,4620.60742,2852.840,
3542.12695,2304.598,4620.69873,2852.840,
3542.21851,2304.598,4620.79053,2852.840,
3542.31006,2304.598,4620.88184,2853.840,
3542.40161,2304.598,4620.97314,2853.840,
3542.49316,2305.598,4621.06494,2852.840,
3542.58447,2306.598,4621.15625,2853.840,
3542.67603,2306.598,4621.24805,2852.840,
3542.76758,2306.598,4621.33936,2853.840,
3542.85913,2307.598,4621.43115,2853.840,
3542.95068,2307.598,4621.52246,2853.840,
3543.04224,2308.598,4621.61426,2853.840,
3543.13379,2309.598,4621.70557,2853.840,
3543.22534,2309.598,4621.79688,2853.840,
3543.31665,2310.598,4621.88867,2853.840,
3543.40820,2310.598,4621.97998,2853.840,
3543.49976,2310.598,4622.07178,2853.840,
3543.59131,2311.598,4622.16309,2853.840,
3543.68286,2311.598,4622.25488,2853.840,
3543.77441,2311.598,4622.34619,2853.840,
3543.86597,2311.598,4622.43750,2853.840,
3543.95728,2311.598,4622.52930,2853.840,
3544.04883,2311.598,4622.62061,2853.840,
3544.14038,2313.598,4622.71240,2853.840,
3544.23193,2312.598,4622.80371,2853.840,
3544.32349,2313.598,4622.89551,2853.840,
3544.41504,2313.598,4622.98682,2853.840,
3544.50659,2313.598,4623.07813,2853.840,
3544.59814,2314.598,4623.16992,2853.840,
3544.68945,2314.598,4623.26123,2853.840,
3544.78101,2314.598,4623.35303,2853.840,
3544.87256,2314.598,4623.44434,2853.840,
3544.96411,2315.598,4623.53613,2853.840,
3545.05566,2315.598,4623.62744,2854.840,
3545.14722,2315.598,4623.71924,2853.840,
3545.23877,2315.598,4623.81055,2855.840,
3545.33008,2315.598,4623.90186,2855.840,
3545.42163,2315.598,4623.99365,2854.840,
3545.51318,2316.598,4624.08496,2854.840,
3545.60474,2316.598,4624.17676,2855.840,
3545.69629,2316.598,4624.26807,2855.840,
3545.78784,2316.598,4624.35986,2855.840,
3545.87939,2316.598,4624.45117,2855.840,
3545.97095,2317.598,4624.54248,2855.840,
3546.06226,2318.598,4624.63428,2855.840,
3546.15381,2317.598,4624.72559,2855.840,
3546.24536,2318.598,4624.81738,2855.840,
3546.33691,2318.598,4624.90869,2855.840,
3546.42847,2318.598,4625.00049,2855.840,
3546.52002,2319.598,4625.09180,2855.840,
3546.61157,2319.598,4625.18311,2855.840,
3546.70313,2319.598,4625.27490,2855.840,
3546.79443,2319.598,4625.36621,2854.840,
3546.88599,2319.598,4625.45801,2854.840,
3546.97754,2319.598,4625.54932,2854.840,
3547.06909,2320.598,4625.64111,2855.840,
3547.16064,2320.598,4625.73242,2855.840,
3547.25220,2320.598,4625.82422,2855.840,
3547.34375,2321.598,4625.91553,2855.840,
3547.43506,2321.598,4626.00684,2855.840,
3547.52661,2322.598,4626.09863,2856.840,
3547.61816,2321.598,4626.18994,2856.840,
3547.70972,2321.598,4626.28174,2856.840,
3547.80127,2322.598,4626.37305,2857.840,
3547.89282,2321.598,4626.46484,2856.840,
3547.98438,2321.598,4626.55615,2856.840,
3548.07593,2322.598,4626.64746,2857.840,
3548.16724,2322.598,4626.73926,2857.840,
3548.25879,2322.598,4626.83057,2857.840,
3548.35034,2322.598,4626.92236,2857.840,
3548.44189,2323.598,4627.01367,2857.840,
3548.53345,2323.598,4627.10547,2857.840,
3548.62500,2324.598,4627.19678,2857.840,
3548.71655,2324.598,4627.28809,2857.840,
3548.80811,2324.598,4627.37988,2857.840,
3548.89941,2325.598,4627.47119,2857.840,
3548.99097,2325.598,4627.56299,2857.840,
3549.08252,2325.598,4627.65430,2857.840,
3549.17407,2325.598,4627.74609,2858.840,
3549.26563,2325.598,4627.83740,2857.840,
3549.35718,2326.598,4627.92920,2857.840,
3549.44873,2326.598,4628.02051,2858.840,
3549.54004,2326.598,4628.11182,2858.840,
3549.63159,2327.598,4628.20361,2858.840,
3549.72314,2327.598,4628.29492,2858.840,
3549.81470,2327.598,4628.38672,2858.840,
3549.90625,2327.598,4628.47803,2858.840,
3549.99780,2327.598,4628.56982,2858.840,
3550.08936,2327.598,4628.66113,2859.840,
3550.18091,2328.598,4628.75244,2858.840,
3550.27222,2328.598,4628.84424,2858.840,
3550.36377,2328.598,4628.93555,2858.840,
3550.45532,2329.598,4629.02734,2858.840,
3550.54688,2329.598,4629.11865,2858.840,
3550.63843,2329.598,4629.21045,2859.840,
3550.72998,2329.598,4629.30176,2859.840,
3550.82153,2330.598,4629.39307,2858.840,
3550.91284,2329.598,4629.48486,2859.840,
3551.00439,2330.598,4629.57617,2859.840,
3551.09595,2330.598,4629.66797,2860.840,
3551.18750,2330.598,4629.75928,2859.840,
3551.27905,2330.598,4629.85107,2859.840,
3551.37061,2331.598,4629.94238,2859.840,
3551.46216,2331.598,4630.03418,2859.840,
3551.55371,2331.598,4630.12549,2859.840,
3551.64502,2331.598,4630.21680,2859.840,
3551.73657,2331.598,4630.30859,2859.840,
3551.82813,2331.598,4630.39990,2859.840,
3551.91968,2333.598,4630.49170,2859.840,
3552.01123,2332.598,4630.58301,2860.840,
3552.10278,2332.598,4630.67480,2859.840,
3552.19434,2333.598,4630.76611,2859.840,
3552.28589,2333.598,4630.85742,2859.840,
3552.37720,2333.598,4630.94922,2859.840,
3552.46875,2333.598,4631.04053,2859.840,
3552.56030,2333.598,4631.13232,2860.840,
3552.65186,2334.598,4631.22363,2860.840,
3552.74341,2333.598,4631.31543,2860.840,
3552.83496,2334.598,4631.40674,2860.840,
3552.92651,2335.598,4631.49805,2860.840,
3553.01782,2334.598,4631.58984,2860.840,
3553.10938,2335.598,4631.68115,2860.840,
3553.20093,2335.598,4631.77295,2860.840,
3553.29248,2335.598,4631.86426,2861.840,
3553.38403,2336.598,4631.95605,2861.840,
3553.47559,2336.598,4632.04736,2860.840,
3553.56714,2336.598,4632.13916,2861.840,
3553.65869,2336.598,4632.23047,2860.840,
3553.75000,2337.598,4632.32178,2860.840,
3553.84155,2337.598,4632.41357,2861.840,
3553.93311,2337.598,4632.50488,2861.840,
3554.02466,2337.598,4632.59668,2861.840,
3554.11621,2337.598,4632.68799,2860.840,
3554.20776,2337.598,4632.77979,2861.840,
3554.29932,2338.598,4632.87109,2861.840,
3554.39087,2338.598,4632.96240,2861.840,
3554.48218,2338.598,4633.05420,2861.840,
3554.57373,2338.598,4633.14551,2861.840,
3554.66528,2339.598,4633.23730,2861.840,
3554.75684,2339.598,4633.32861,2861.840,
3554.84839,2340.598,4633.42041,2861.840,
3554.93994,2339.598,4633.51172,2861.840,
3555.03149,2339.598,4633.60303,2861.840,
3555.12280,2340.598,4633.69482,2862.840,
3555.21436,2340.598,4633.78613,2861.840,
3555.30591,2340.598,4633.87793,2861.840,
3555.39746,2340.598,4633.96924,2862.840,
3555.48901,2341.598,4634.06104,2862.840,
3555.58057,2341.598,4634.15234,2862.840,
3555.67212,2341.598,4634.24365,2862.840,
3555.76367,2342.598,4634.33545,2862.840,
3555.85498,2342.598,4634.42676,2862.840,
3555.94653,2342.598,4634.51855,2862.840,
3556.03809,2342.598,4634.60986,2862.840,
3556.12964,2342.598,4634.70166,2862.840,
3556.22119,2343.598,4634.79297,2863.840,
3556.31274,2343.598,4634.88477,2862.840,
3556.40430,2343.598,4634.97607,2862.840,
3556.49585,2344.598,4635.06738,2862.840,
3556.58716,2344.598,4635.15918,2862.840,
3556.67871,2344.598,4635.25049,2862.840,
3556.77026,2345.598,4635.34229,2863.840,
3556.86182,2344.598,4635.43359,2863.840,
3556.95337,2345.598,4635.52539,2863.840,
3557.04492,2345.598,4635.61670,2863.840,
3557.13647,2345.598,4635.70801,2863.840,
3557.22778,2345.598,4635.79980,2863.840,
3557.31934,2345.598,4635.89111,2863.840,
3557.41089,2345.598,4635.98291,2864.840,
3557.50244,2346.598,4636.07422,2863.840,
3557.59399,2346.598,4636.16602,2863.840,
3557.68555,2346.598,4636.25732,2864.840,
3557.77710,2347.598,4636.34863,2864.840,
3557.86865,2347.598,4636.44043,2863.840,
3557.95996,2347.598,4636.53174,2863.840,
3558.05151,2347.598,4636.62354,2863.840,
3558.14307,2347.598,4636.71484,2864.840,
3558.23462,2347.598,4636.80664,2864.840,
3558.32617,2348.598,4636.89795,2864.840,
3558.41772,2348.598,4636.98975,2865.840,
3558.50928,2348.598,4637.08105,2864.840,
3558.60059,2348.598,4637.17236,2864.840,
3558.69214,2348.598,4637.26416,2864.840,
3558.78369,2349.598,4637.35547,2864.840,
3558.87524,2349.598,4637.44727,2864.840,
3558.96680,2349.598,4637.53857,2864.840,
3559.05835,2349.598,4637.63037,2864.840,
3559.14990,2349.598,4637.72168,2864.840,
3559.24146,2350.598,4637.81299,2864.840,
3559.33276,2350.598,4637.90479,2864.840,
3559.42432,2351.598,4637.99609,2865.840,
3559.51587,2351.598,4638.08789,2864.840,
3559.60742,2351.598,4638.17920,2864.840,
3559.69897,2352.598,4638.27100,2865.840,
3559.79053,2353.598,4638.36230,2864.840,
3559.88208,2353.598,4638.45361,2865.840,
3559.97363,2354.598,4638.54541,2864.840,
3560.06494,2354.598,4638.63672,2865.840,
3560.15649,2355.598,4638.72852,2865.840,
3560.24805,2355.598,4638.81982,2865.840,
3560.33960,2355.598,4638.91162,2865.840,
3560.43115,2355.598,4639.00293,2865.840,
3560.52271,2355.598,4639.09473,2865.840,
3560.61426,2355.598,4639.18604,2865.840,
3560.70557,2356.598,4639.27734,2865.840,
3560.79712,2356.598,4639.36914,2865.840,
3560.88867,2356.598,4639.46045,2865.840,
3560.98022,2355.598,4639.55225,2865.840,
3561.07178,2355.598,4639.64355,2865.840,
3561.16333,2355.598,4639.73535,2865.840,
3561.25488,2356.598,4639.82666,2865.840,
3561.34644,2355.598,4639.91797,2866.840,
3561.43774,2356.598,4640.00977,2866.840,
3561.52930,2356.598,4640.10107,2866.840,
3561.62085,2356.598,4640.19287,2866.840,
3561.71240,2356.598,4640.28418,2866.840,
3561.80396,2355.598,4640.37598,2866.840,
3561.89551,2356.598,4640.46729,2867.840,
3561.98706,2355.598,4640.55859,2867.840,
3562.07861,2356.598,4640.65039,2867.840,
3562.16992,2356.598,4640.74170,2866.840,
3562.26147,2355.598,4640.83350,2866.840,
3562.35303,2355.598,4640.92480,2866.840,
3562.44458,2355.598,4641.01660,2866.840,
3562.53613,2355.598,4641.10791,2866.840,
3562.62769,2355.598,4641.19971,2866.840,
3562.71924,2356.598,4641.29102,2867.840,
3562.81055,2356.598,4641.38232,2867.840,
3562.90210,2357.598,4641.47412,2866.840,
3562.99365,2357.598,4641.56543,2866.840,
3563.08521,2358.598,4641.65723,2867.840,
3563.17676,2359.598,4641.74854,2867.840,
3563.26831,2359.598,4641.84033,2867.840,
3563.35986,2359.598,4641.93164,2866.840,
3563.45142,2359.598,4642.02295,2867.840,
3563.54272,2359.598,4642.11475,2867.840,
3563.63428,2361.598,4642.20605,2867.840,
3563.72583,2361.598,4642.29785,2867.840,
3563.81738,2361.598,4642.38916,2867.840,
3563.90894,2361.598,4642.48096,2867.840,
3564.00049,2362.598,4642.57227,2867.840,
3564.09204,2362.598,4642.66357,2867.840,
3564.18335,2362.598,4642.75537,2867.840,
3564.27490,2363.598,4642.84668,2868.840,
3564.36646,2362.598,4642.93848,2867.840,
3564.45801,2363.598,4643.02979,2868.840,
3564.54956,2363.598,4643.12158,2868.840,
3564.64111,2363.598,4643.21289,2868.840,
3564.73267,2363.598,4643.30469,2867.840,
3564.82422,2364.598,4643.39600,2868.840,
3564.91553,2364.598,4643.48730,2868.840,
3565.00708,2364.598,4643.57910,2868.840,
3565.09863,2364.598,4643.67041,2867.840,
3565.19019,2365.598,4643.76221,2868.840,
3565.28174,2364.598,4643.85352,2867.840,
3565.37329,2365.598,4643.94531,2868.840,
3565.46484,2365.598,4644.03662,2868.840,
3565.55640,2365.598,4644.12793,2868.840,
3565.64771,2366.598,4644.21973,2868.840,
3565.73926,2366.598,4644.31104,2869.840,
3565.83081,2366.598,4644.40283,2869.840,
3565.92236,2367.598,4644.49414,2868.840,
3566.01392,2367.598,4644.58594,2868.840,
3566.10547,2367.598,4644.67725,2869.840,
3566.19702,2367.598,4644.76855,2868.840,
3566.28833,2367.598,4644.86035,2868.840,
3566.37988,2367.598,4644.95166,2869.840,
3566.47144,2367.598,4645.04346,2868.840,
3566.56299,2368.598,4645.13477,2868.840,
3566.65454,2368.598,4645.22656,2868.840,
3566.74609,2368.598,4645.31787,2868.840,
3566.83765,2368.598,4645.40918,2869.840,
3566.92920,2369.598,4645.50098,2869.840,
3567.02051,2368.598,4645.59229,2869.840,
3567.11206,2369.598,4645.68408,2868.840,
3567.20361,2370.598,4645.77539,2869.840,
3567.29517,2370.598,4645.86719,2868.840,
3567.38672,2369.598,4645.95850,2869.840,
3567.47827,2370.598,4646.05029,2869.840,
3567.56982,2370.598,4646.14160,2869.840,
3567.66138,2371.598,4646.23291,2869.840,
3567.75269,2371.598,4646.32471,2869.840,
3567.84424,2370.598,4646.41602,2869.840,
3567.93579,2371.598,4646.50781,2869.840,
3568.02734,2372.598,4646.59912,2869.840,
3568.11890,2372.598,4646.69092,2869.840,
3568.21045,2372.598,4646.78223,2869.840,
3568.30200,2372.598,4646.87354,2869.840,
3568.39331,2372.598,4646.96533,2869.840,
3568.48486,2372.598,4647.05664,2869.840,
3568.57642,2373.598,4647.14844,2869.840,
3568.66797,2373.598,4647.23975,2870.840,
3568.75952,2373.598,4647.33154,2870.840,
3568.85107,2373.598,4647.42285,2869.840,
3568.94263,2374.598,4647.51416,2869.840,
3569.03418,2374.598,4647.60596,2869.840,
3569.12549,2373.598,4647.69727,2869.840,
3569.21704,2374.598,4647.78906,2868.840,
3569.30859,2375.598,4647.88037,2868.840,
3569.40015,2374.598,4647.97217,2869.840,
3569.49170,2375.598,4648.06348,2868.840,
3569.58325,2375.598,4648.15527,2868.840,
3569.67480,2375.598,4648.24658,2869.840,
3569.76611,2376.598,4648.33789,2869.840,
3569.85767,2376.598,4648.42969,2869.840,
3569.94922,2375.598,4648.52100,2869.840,
3570.04077,2376.598,4648.61279,2870.840,
3570.13232,2377.598,4648.70410,2871.840,
3570.22388,2376.598,4648.79590,2870.840,
3570.31543,2376.598,4648.88721,2870.840,
3570.40698,2377.598,4648.97852,2870.840,
3570.49829,2377.598,4649.07031,2870.840,
3570.58984,2377.598,4649.16162,2870.840,
3570.68140,2378.598,4649.25342,2870.840,
3570.77295,2378.598,4649.34473,2871.840,
3570.86450,2378.598,4649.43652,2870.840,
3570.95605,2379.598,4649.52783,2870.840,
3571.04761,2378.598,4649.61914,2871.840,
3571.13916,2378.598,4649.71094,2871.840,
3571.23047,2378.598,4649.80225,2871.840,
3571.32202,2379.598,4649.89404,2871.840,
3571.41357,2379.598,4649.98535,2871.840,
3571.50513,2379.598,4650.07715,2871.840,
3571.59668,2380.598,4650.16846,2871.840,
3571.68823,2380.598,4650.26025,2871.840,
3571.77979,2380.598,4650.35156,2871.840,
3571.87109,2380.598,4650.44287,2871.840,
3571.96265,2381.598,4650.53467,2871.840,
3572.05420,2381.598,4650.62598,2871.840,
3572.14575,2381.598,4650.71777,2871.840,
3572.23730,2382.598,4650.80908,2871.840,
3572.32886,2381.598,4650.90088,2871.840,
3572.42041,2383.598,4650.99219,2871.840,
3572.51196,2382.598,4651.08350,2872.840,
3572.60327,2382.598,4651.17529,2872.840,
3572.69482,2383.598,4651.26660,2871.840,
3572.78638,2383.598,4651.35840,2871.840,
3572.87793,2384.598,4651.44971,2871.840,
3572.96948,2383.598,4651.54150,2871.840,
3573.06104,2383.598,4651.63281,2871.840,
3573.15259,2384.598,4651.72412,2871.840,
3573.24414,2384.598,4651.81592,2871.840,
3573.33545,2384.598,4651.90723,2871.840,
3573.42700,2384.598,4651.99902,2872.840,
3573.51855,2384.598,4652.09033,2872.840,
3573.61011,2384.598,4652.18213,2872.840,
3573.70166,2385.598,4652.27344,2872.840,
3573.79321,2385.598,4652.36523,2872.840,
3573.88477,2386.598,4652.45654,2872.840,
3573.97607,2386.598,4652.54785,2872.840,
3574.06763,2386.598,4652.63965,2872.840,
3574.15918,2386.598,4652.73096,2872.840,
3574.25073,2386.598,4652.82275,2872.840,
3574.34229,2386.598,4652.91406,2872.840,
3574.43384,2387.598,4653.00586,2872.840,
3574.52539,2387.598,4653.09717,2872.840,
3574.61694,2387.598,4653.18848,2872.840,
3574.70825,2387.598,4653.28027,2872.840,
3574.79980,2388.598,4653.37158,2872.840,
3574.89136,2388.598,4653.46338,2872.840,
3574.98291,2388.598,4653.55469,2873.840,
3575.07446,2388.598,4653.64648,2872.840,
3575.16602,2388.598,4653.73779,2873.840,
3575.25757,2389.598,4653.82910,2873.840,
3575.34912,2389.598,4653.92090,2873.840,
3575.44043,2389.598,4654.01221,2872.840,
3575.53198,2389.598,4654.10400,2873.840,
3575.62354,2390.598,4654.19531,2873.840,
3575.71509,2390.598,4654.28711,2873.840,
3575.80664,2390.598,4654.37842,2873.840,
3575.89819,2390.598,4654.47021,2873.840,
3575.98975,2390.598,4654.56152,2873.840,
3576.08105,2391.598,4654.65283,2873.840,
3576.17261,2391.598,4654.74463,2874.840,
3576.26416,2391.598,4654.83594,2873.840,
3576.35571,2391.598,4654.92773,2873.840,
3576.44727,2391.598,4655.01904,2873.840,
3576.53882,2391.598,4655.11084,2873.840,
3576.63037,2392.598,4655.20215,2873.840,
3576.72192,2392.598,4655.29346,2873.840,
3576.81323,2392.598,4655.38525,2873.840,
3576.90479,2392.598,4655.47656,2873.840,
3576.99634,2393.598,4655.56836,2873.840,
3577.08789,2393.598,4655.65967,2874.840,
3577.17944,2393.598,4655.75146,2873.840,
3577.27100,2394.598,4655.84277,2874.840,
3577.36255,2394.598,4655.93408,2873.840,
3577.45386,2394.598,4656.02588,2874.840,
3577.54541,2394.598,4656.11719,2874.840,
3577.63696,2394.598,4656.20898,2874.840,
3577.72852,2394.598,4656.30029,2873.840,
3577.82007,2395.598,4656.39209,2874.840,
3577.91162,2395.598,4656.48340,2873.840,
3578.00317,2395.598,4656.57520,2874.840,
3578.09473,2395.598,4656.66650,2874.840,
3578.18604,2396.598,4656.75781,2874.840,
3578.27759,2397.598,4656.84961,2873.840,
3578.36914,2396.598,4656.94092,2874.840,
3578.46069,2396.598,4657.03271,2873.840,
3578.55225,2396.598,4657.12402,2873.840,
3578.64380,2397.598,4657.21582,2874.840,
3578.73535,2397.598,4657.30713,2874.840,
3578.82690,2397.598,4657.39844,2874.840,
3578.91821,2397.598,4657.49023,2874.840,
3579.00977,2398.598,4657.58154,2874.840,
3579.10132,2397.598,4657.67334,2874.840,
3579.19287,2398.598,4657.76465,2874.840,
3579.28442,2398.598,4657.85645,2874.840,
3579.37598,2399.598,4657.94775,2874.840,
3579.46753,2399.598,4658.03906,2875.840,
3579.55884,2399.598,4658.13086,2874.840,
3579.65039,2399.598,4658.22217,2875.840,
3579.74194,2400.598,4658.31396,2874.840,
3579.83350,2399.598,4658.40527,2874.840,
3579.92505,2399.598,4658.49707,2875.840,
3580.01660,2400.598,4658.58838,2875.840,
3580.10815,2400.598,4658.67969,2874.840,
3580.19971,2401.598,4658.77148,2874.840,
3580.29102,2402.598,4658.86279,2875.840,
3580.38257,2402.598,4658.95459,2875.840,
3580.47412,2403.598,4659.04590,2875.840,
3580.56567,2404.598,4659.13770,2874.840,
3580.65723,2404.598,4659.22900,2874.840,
3580.74878,2404.598,4659.32080,2875.840,
3580.84033,2405.598,4659.41211,2875.840,
3580.93188,2405.598,4659.50342,2875.840,
3581.02319,2405.598,4659.59521,2875.840,
3581.11475,2405.598,4659.68652,2875.840,
3581.20630,2406.598,4659.77832,2875.840,
3581.29785,2405.598,4659.86963,2874.840,
3581.38940,2405.598,4659.96143,2875.840,
3581.48096,2405.598,4660.05273,2875.840,
3581.57251,2405.598,4660.14404,2875.840,
3581.66382,2405.598,4660.23584,2875.840,
3581.75537,2405.598,4660.32715,2876.840,
3581.84692,2405.598,4660.41895,2876.840,
3581.93848,2405.598,4660.51025,2875.840,
3582.03003,2405.598,4660.60205,2875.840,
3582.12158,2405.598,4660.69336,2875.840,
3582.21313,2405.598,4660.78467,2875.840,
3582.30469,2406.598,4660.87646,2875.840,
3582.39600,2406.598,4660.96777,2875.840,
3582.48755,2405.598,4661.05957,2875.840,
3582.57910,2405.598,4661.15088,2876.840,
3582.67065,2405.598,4661.24268,2875.840,
3582.76221,2404.598,4661.33398,2875.840,
3582.85376,2403.598,4661.42578,2875.840,
3582.94531,2403.598,4661.51709,2876.840,
3583.03662,2403.598,4661.60840,2875.840,
3583.12817,2403.598,4661.70020,2875.840,
3583.21973,2404.598,4661.79150,2876.840,
3583.31128,2404.598,4661.88330,2876.840,
3583.40283,2405.598,4661.97461,2875.840,
3583.49438,2405.598,4662.06641,2875.840,
3583.58594,2405.598,4662.15771,2876.840,
3583.67749,2406.598,4662.24902,2875.840,
3583.76880,2406.598,4662.34082,2875.840,
3583.86035,2407.598,4662.43213,2876.840,
3583.95190,2408.598,4662.52393,2875.840,
3584.04346,2408.598,4662.61523,2875.840,
3584.13501,2409.598,4662.70703,2875.840,
3584.22656,2408.598,4662.79834,2875.840,
3584.31812,2409.598,4662.88965,2876.840,
3584.40967,2409.598,4662.98145,2876.840,
3584.50098,2410.598,4663.07275,2875.840,
3584.59253,2410.598,4663.16455,2876.840,
3584.68408,2410.598,4663.25586,2876.840,
3584.77563,2411.598,4663.34766,2877.840,
3584.86719,2411.598,4663.43896,2876.840,
3584.95874,2411.598,4663.53076,2876.840,
3585.05029,2411.598,4663.62207,2876.840,
3585.14160,2411.598,4663.71338,2876.840,
3585.23315,2411.598,4663.80518,2876.840,
3585.32471,2412.598,4663.89648,2876.840,
3585.41626,2412.598,4663.98828,2876.840,
3585.50781,2412.598,4664.07959,2876.840,
3585.59937,2413.598,4664.17139,2876.840,
3585.69092,2413.598,4664.26270,2876.840,
3585.78247,2413.598,4664.35400,2876.840,
3585.87378,2414.598,4664.44580,2876.840,
3585.96533,2414.598,4664.53711,2876.840,
3586.05688,2414.598,4664.62891,2876.840,
3586.14844,2414.598,4664.72021,2876.840,
3586.23999,2415.598,4664.81201,2877.840,
3586.33154,2415.598,4664.90332,2876.840,
3586.42310,2415.598,4664.99463,2876.840,
3586.51465,2415.598,4665.08643,2876.840,
3586.60596,2415.598,4665.17773,2877.840,
3586.69751,2415.598,4665.26953,2876.840,
3586.78906,2416.598,4665.36084,2877.840,
3586.88062,2416.598,4665.45264,2877.840,
3586.97217,2416.598,4665.54395,2876.840,
3587.06372,2417.598,4665.63574,2876.840,
3587.15527,2417.598,4665.72705,2876.840,
3587.24658,2417.598,4665.81836,2877.840,
3587.33813,2417.598,4665.91016,2876.840,
3587.42969,2418.598,4666.00146,2877.840,
3587.52124,2418.598,4666.09326,2876.840,
3587.61279,2418.598,4666.18457,2876.840,
3587.70435,2418.598,4666.27637,2877.840,
3587.79590,2418.598,4666.36768,2877.840,
3587.88745,2419.598,4666.45898,2877.840,
3587.97876,2419.598,4666.55078,2877.840,
3588.07031,2419.598,4666.64209,2877.840,
3588.16187,2419.598,4666.73389,2877.840,
3588.25342,2419.598,4666.82520,2877.840,
3588.34497,2420.598,4666.91699,2877.840,
3588.43652,2420.598,4667.00830,2876.840,
3588.52808,2421.598,4667.09961,2877.840,
3588.61938,2421.598,4667.19141,2877.840,
3588.71094,2421.598,4667.28271,2877.840,
3588.80249,2421.598,4667.37451,2877.840,
3588.89404,2421.598,4667.46582,2877.840,
3588.98560,2422.598,4667.55762,2876.840,
3589.07715,2421.598,4667.64893,2876.840,
3589.16870,2422.598,4667.74072,2877.840,
3589.26025,2422.598,4667.83203,2877.840,
3589.35156,2422.598,4667.92334,2876.840,
3589.44312,2422.598,4668.01514,2876.840,
3589.53467,2423.598,4668.10645,2877.840,
3589.62622,2423.598,4668.19824,2877.840,
3589.71777,2423.598,4668.28955,2877.840,
3589.80933,2423.598,4668.38135,2877.840,
3589.90088,2424.598,4668.47266,2877.840,
3589.99243,2424.598,4668.56396,2877.840,
3590.08374,2424.598,4668.65576,2877.840,
3590.17529,2424.598,4668.74707,2876.840,
3590.26685,2425.598,4668.83887,2877.840,
3590.35840,2425.598,4668.93018,2877.840,
3590.44995,2425.598,4669.02197,2877.840,
3590.54150,2425.598,4669.11328,2877.840,
3590.63306,2425.598,4669.20459,2877.840,
3590.72437,2426.598,4669.29639,2877.840,
3590.81592,2425.598,4669.38770,2877.840,
3590.90747,2425.598,4669.47949,2877.840,
3590.99902,2426.598,4669.57080,2877.840,
3591.09058,2426.598,4669.66260,2877.840,
3591.18213,2426.598,4669.75391,2877.840,
3591.27368,2427.598,4669.84570,2877.840,
3591.36523,2427.598,4669.93701,2877.840,
3591.45654,2428.598,4670.02832,2877.840,
3591.54810,2427.598,4670.12012,2877.840,
3591.63965,2427.598,4670.21143,2876.840,
3591.73120,2428.598,4670.30322,2876.840,
3591.82275,2428.598,4670.39453,2876.840,
3591.91431,2428.598,4670.48633,2877.840,
3592.00586,2428.598,4670.57764,2876.840,
3592.09741,2428.598,4670.66895,2877.840,
3592.18872,2429.598,4670.76074,2877.840,
3592.28027,2429.598,4670.85205,2877.840,
3592.37183,2429.598,4670.94385,2877.840,
3592.46338,2429.598,4671.03516,2877.840,
3592.55493,2430.598,4671.12695,2877.840,
3592.64648,2429.598,4671.21826,2878.840,
3592.73804,2430.598,4671.30957,2878.840,
3592.82935,2430.598,4671.40137,2878.840,
3592.92090,2431.598,4671.49268,2878.840,
3593.01245,2431.598,4671.58447,2878.840,
3593.10400,2431.598,4671.67578,2878.840,
3593.19556,2431.598,4671.76758,2878.840,
3593.28711,2431.598,4671.85889,2878.840,
3593.37866,2432.598,4671.95020,2878.840,
3593.47021,2431.598,4672.04199,2878.840,
3593.56152,2432.598,4672.13330,2878.840,
3593.65308,2432.598,4672.22510,2878.840,
3593.74463,2432.598,4672.31641,2878.840,
3593.83618,2432.598,4672.40820,2878.840,
3593.92773,2433.598,4672.49951,2878.840,
3594.01929,2433.598,4672.59131,2878.840,
3594.11084,2433.598,4672.68262,2878.840,
3594.20239,2433.598,4672.77393,2878.840,
3594.29370,2433.598,4672.86572,2878.840,
3594.38525,2434.598,4672.95703,2878.840,
3594.47681,2434.598,4673.04883,2878.840,
3594.56836,2434.598,4673.14014,2878.840,
3594.65991,2435.598,4673.23193,2878.840,
3594.75146,2435.598,4673.32324,2878.840,
3594.84302,2435.598,4673.41455,2878.840,
3594.93433,2435.598,4673.50635,2878.840,
3595.02588,2435.598,4673.59766,2879.840,
3595.11743,2435.598,4673.68945,2878.840,
3595.20898,2436.598,4673.78076,2878.840,
3595.30054,2436.598,4673.87256,2878.840,
3595.39209,2436.598,4673.96387,2878.840,
3595.48364,2436.598,4674.05518,2878.840,
3595.57520,2437.598,4674.14697,2878.840,
3595.66650,2437.598,4674.23828,2879.840,
3595.75806,2437.598,4674.33008,2878.840,
3595.84961,2438.598,4674.42139,2878.840,
3595.94116,2437.598,4674.51318,2878.840,
3596.03271,2438.598,4674.60449,2878.840,
3596.12427,2438.598,4674.69629,2878.840,
3596.21582,2438.598,4674.78760,2878.840,
3596.30713,2438.598,4674.87891,2878.840,
3596.39868,2438.598,4674.97070,2878.840,
3596.49023,2439.598,4675.06201,2879.840,
3596.58179,2439.598,4675.15381,2879.840,
3596.67334,2439.598,4675.24512,2878.840,
3596.76489,2439.598,4675.33691,2879.840,
3596.85645,2440.598,4675.42822,2879.840,
3596.94800,2440.598,4675.51953,2878.840,
3597.03931,2440.598,4675.61133,2879.840,
3597.13086,2440.598,4675.70264,2879.840,
3597.22241,2440.598,4675.79443,2879.840,
3597.31396,2441.598,4675.88574,2879.840,
3597.40552,2441.598,4675.97754,2879.840,
3597.49707,2442.598,4676.06885,2878.840,
3597.58862,2442.598,4676.16016,2878.840,
3597.68018,2442.598,4676.25195,2878.840,
3597.77148,2442.598,4676.34326,2879.840,
3597.86304,2442.598,4676.43506,2878.840,
3597.95459,2442.598,4676.52637,2879.840,
3598.04614,2443.598,4676.61816,2879.840,
3598.13770,2443.598,4676.70947,2879.840,
3598.22925,2442.598,4676.80127,2878.840,
3598.32080,2443.598,4676.89258,2878.840,
3598.41211,2443.598,4676.98389,2879.840,
3598.50366,2444.598,4677.07568,2879.840,
3598.59521,2444.598,4677.16699,2878.840,
3598.68677,2443.598,4677.25879,2879.840,
3598.77832,2445.598,4677.35010,2878.840,
3598.86987,2444.598,4677.44189,2879.840,
3598.96143,2444.598,4677.53320,2879.840,
3599.05298,2445.598,4677.62451,2879.840,
3599.14429,2445.598,4677.71631,2879.840,
3599.23584,2445.598,4677.80762,2878.840,
3599.32739,2446.598,4677.89941,2879.840,
3599.41895,2445.598,4677.99072,2879.840,
3599.51050,2446.598,4678.08252,2879.840,
3599.60205,2446.598,4678.17383,2879.840,
3599.69360,2446.598,4678.26514,2879.840,
3599.78516,2446.598,4678.35693,2879.840,
3599.87646,2446.598,4678.44824,2879.840,
3599.96802,2447.598,4678.54004,2879.840,
3600.05957,2447.598,4678.63135,2879.840,
3600.15112,2447.598,4678.72314,2879.840,
3600.24268,2448.598,4678.81445,2879.840,
3600.33423,2448.598,4678.90625,2879.840,
3600.42578,2448.598,4678.99756,2879.840,
3600.51709,2448.598,4679.08887,2879.840,
3600.60864,2448.598,4679.18066,2879.840,
3600.70020,2449.598,4679.27197,2879.840,
3600.79175,2449.598,4679.36377,2879.840,
3600.88330,2449.598,4679.45508,2880.840,
3600.97485,2448.598,4679.54688,2879.840,
3601.06641,2449.598,4679.63818,2879.840,
3601.15796,2449.598,4679.72949,2879.840,
3601.24927,2450.598,4679.82129,2879.840,
3601.34082,2450.598,4679.91260,2879.840,
3601.43237,2450.598,4680.00439,2879.840,
3601.52393,2450.598,4680.09570,2879.840,
3601.61548,2451.598,4680.18750,2879.840,
3601.70703,2451.598,4680.27881,2879.840,
3601.79858,2451.598,4680.37012,2879.840,
3601.88989,2450.598,4680.46191,2879.840,
3601.98145,2451.598,4680.55322,2879.840,
3602.07300,2451.598,4680.64502,2879.840,
3602.16455,2451.598,4680.73633,2880.840,
3602.25610,2452.598,4680.82813,2879.840,
3602.34766,2452.598,4680.91943,2880.840,
3602.43921,2452.598,4681.01123,2879.840,
3602.53076,2452.598,4681.10254,2879.840,
3602.62207,2453.598,4681.19385,2879.840,
3602.71362,2453.598,4681.28564,2879.840,
3602.80518,2453.598,4681.37695,2879.840,
3602.89673,2453.598,4681.46875,2880.840,
3602.98828,2454.598,4681.56006,2879.840,
3603.07983,2454.598,4681.65186,2879.840,
3603.17139,2455.598,4681.74316,2879.840,
3603.26294,2454.598,4681.83447,2879.840,
3603.35425,2455.598,4681.92627,2879.840,
3603.44580,2455.598,4682.01758,2879.840,
3603.53735,2455.598,4682.10938,2879.840,
3603.62891,2455.598,4682.20068,2879.840,
3603.72046,2455.598,4682.29248,2879.840,
3603.81201,2456.598,4682.38379,2880.840,
3603.90356,2456.598,4682.47510,2880.840,
3603.99487,2456.598,4682.56689,2880.840,
3604.08643,2456.598,4682.65820,2879.840,
3604.17798,2456.598,4682.75000,2879.840,
3604.26953,2456.598,4682.84131,2879.840,
3604.36108,2457.598,4682.93311,2879.840,
3604.45264,2457.598,4683.02441,2879.840,
3604.54419,2457.598,4683.11572,2879.840,
3604.63574,2457.598,4683.20752,2879.840,
3604.72705,2457.598,4683.29883,2880.840,
3604.81860,2458.598,4683.39063,2879.840,
3604.91016,2458.598,4683.48193,2879.840,
3605.00171,2458.598,4683.57373,2880.840,
3605.09326,2458.598,4683.66504,2880.840,
3605.18481,2458.598,4683.75684,2880.840,
3605.27637,2459.598,4683.84814,2880.840,
3605.36792,2459.598,4683.93945,2879.840,
3605.45923,2459.598,4684.03125,2879.840,
3605.55078,2459.598,4684.12256,2879.840,
3605.64233,2460.598,4684.21436,2879.840,
3605.73389,2460.598,4684.30566,2879.840,
3605.82544,2460.598,4684.39746,2879.840,
3605.91699,2460.598,4684.48877,2879.840,
3606.00854,2460.598,4684.58008,2879.840,
3606.09985,2461.598,4684.67188,2879.840,
3606.19141,2461.598,4684.76318,2879.840,
3606.28296,2461.598,4684.85498,2879.840,
3606.37451,2461.598,4684.94629,2879.840,
3606.46606,2462.598,4685.03809,2879.840,
3606.55762,2461.598,4685.12939,2879.840,
3606.64917,2462.598,4685.22070,2880.840,
3606.74072,2463.598,4685.31250,2880.840,
3606.83203,2463.598,4685.40381,2880.840,
3606.92358,2463.598,4685.49561,2880.840,
3607.01514,2463.598,4685.58691,2880.840,
3607.10669,2463.598,4685.67871,2879.840,
3607.19824,2463.598,4685.77002,2879.840,
3607.28979,2463.598,4685.86182,2880.840,
3607.38135,2464.598,4685.95313,2880.840,
3607.47266,2464.598,4686.04443,2880.840,
3607.56421,2465.598,4686.13623,2879.840,
3607.65576,2465.598,4686.22754,2880.840,
3607.74731,2465.598,4686.31934,2879.840,
3607.83887,2465.598,4686.41064,2879.840,
3607.93042,2465.598,4686.50244,2880.840,
3608.02197,2466.598,4686.59375,2880.840,
3608.11353,2466.598,4686.68506,2880.840,
3608.20483,2466.598,4686.77686,2880.840,
3608.29639,2466.598,4686.86816,2880.840,
3608.38794,2466.598,4686.95996,2880.840,
3608.47949,2466.598,4687.05127,2880.840,
3608.57104,2467.598,4687.14307,2879.840,
3608.66260,2466.598,4687.23438,2880.840,
3608.75415,2467.598,4687.32568,2880.840,
3608.84570,2467.598,4687.41748,2880.840,
3608.93701,2467.598,4687.50879,2880.840,
3609.02856,2468.598,4687.60059,2880.840,
3609.12012,2468.598,4687.69189,2879.840,
3609.21167,2468.598,4687.78369,2880.840,
3609.30322,2468.598,4687.87500,2879.840,
3609.39478,2468.598,4687.96680,2879.840,
3609.48633,2468.598,4688.05811,2880.840,
3609.57764,2469.598,4688.14941,2880.840,
3609.66919,2469.598,4688.24121,2880.840,
3609.76074,2469.598,4688.33252,2880.840,
3609.85229,2469.598,4688.42432,2880.840,
3609.94385,2469.598,4688.51563,2879.840,
3610.03540,2469.598,4688.60742,2880.840,
3610.12695,2470.598,4688.69873,2880.840,
3610.21851,2470.598,4688.79004,2880.840,
3610.30981,2470.598,4688.88184,2879.840,
3610.40137,2471.598,4688.97314,2879.840,
3610.49292,2472.598,4689.06494,2880.840,
3610.58447,2471.598,4689.15625,2880.840,
3610.67603,2472.598,4689.24805,2879.840,
3610.76758,2471.598,4689.33936,2879.840,
3610.85913,2472.598,4689.43066,2879.840,
3610.95068,2472.598,4689.52246,2879.840,
3611.04199,2472.598,4689.61377,2878.840,
3611.13354,2473.598,4689.70557,2879.840,
3611.22510,2473.598,4689.79688,2879.840,
3611.31665,2473.598,4689.88867,2878.840,
3611.40820,2473.598,4689.97998,2879.840,
3611.49976,2473.598,4690.07178,2879.840,
3611.59131,2473.598,4690.16309,2879.840,
3611.68262,2473.598,4690.25439,2879.840,
3611.77417,2474.598,4690.34619,2879.840,
3611.86572,2474.598,4690.43750,2880.840,
3611.95728,2475.598,4690.52930,2880.840,
3612.04883,2474.598,4690.62061,2880.840,
3612.14038,2475.598,4690.71240,2879.840,
3612.23193,2475.598,4690.80371,2879.840,
3612.32349,2475.598,4690.89502,2880.840,
3612.41479,2475.598,4690.98682,2880.840,
3612.50635,2475.598,4691.07813,2879.840,
3612.59790,2476.598,4691.16992,2880.840,
3612.68945,2476.598,4691.26123,2880.840,
3612.78101,2476.598,4691.35303,2880.840,
3612.87256,2476.598,4691.44434,2880.840,
3612.96411,2477.598,4691.53564,2879.840,
3613.05566,2477.598,4691.62744,2879.840,
3613.14697,2477.598,4691.71875,2879.840,
3613.23853,2477.598,4691.81055,2878.840,
3613.33008,2477.598,4691.90186,2877.840,
3613.42163,2478.598,4691.99365,2877.840,
3613.51318,2478.598,4692.08496,2878.840,
3613.60474,2478.598,4692.17676,2878.840,
3613.69629,2478.598,4692.26807,2878.840,
3613.78760,2478.598,4692.35938,2878.840,
3613.87915,2479.598,4692.45117,2879.840,
3613.97070,2479.598,4692.54248,2879.840,
3614.06226,2479.598,4692.63428,2879.840,
3614.15381,2479.598,4692.72559,2879.840,
3614.24536,2479.598,4692.81738,2880.840,
3614.33691,2479.598,4692.90869,2880.840,
3614.42847,2479.598,4693.00000,2880.840,
3614.51978,2480.598,4693.09180,2880.840,
3614.61133,2480.598,4693.18311,2880.840,
3614.70288,2480.598,4693.27490,2880.840,
3614.79443,2480.598,4693.36621,2880.840,
3614.88599,2481.598,4693.45801,2879.840,
3614.97754,2481.598,4693.54932,2879.840,
3615.06909,2481.598,4693.64063,2880.840,
3615.16040,2481.598,4693.73242,2879.840,
3615.25195,2481.598,4693.82373,2880.840,
3615.34351,2481.598,4693.91553,2880.840,
3615.43506,2482.598,4694.00684,2879.840,
3615.52661,2482.598,4694.09863,2880.840,
3615.61816,2482.598,4694.18994,2880.840,
3615.70972,2483.598,4694.28174,2880.840,
3615.80127,2483.598,4694.37305,2879.840,
3615.89258,2483.598,4694.46436,2880.840,
3615.98413,2483.598,4694.55615,2880.840,
3616.07568,2483.598,4694.64746,2880.840,
3616.16724,2483.598,4694.73926,2880.840,
3616.25879,2484.598,4694.83057,2880.840,
3616.35034,2485.598,4694.92236,2879.840,
3616.44189,2484.598,4695.01367,2879.840,
3616.53345,2484.598,4695.10498,2880.840,
3616.62476,2485.598,4695.19678,2880.840,
3616.71631,2485.598,4695.28809,2879.840,
3616.80786,2485.598,4695.37988,2880.840,
3616.89941,2485.598,4695.47119,2879.840,
3616.99097,2485.598,4695.56299,2880.840,
3617.08252,2486.598,4695.65430,2879.840,
3617.17407,2486.598,4695.74561,2880.840,
3617.26538,2486.598,4695.83740,2880.840,
3617.35693,2486.598,4695.92871,2880.840,
3617.44849,2486.598,4696.02051,2880.840,
3617.54004,2486.598,4696.11182,2879.840,
3617.63159,2487.598,4696.20361,2880.840,
3617.72314,2487.598,4696.29492,2879.840,
3617.81470,2488.598,4696.38623,2879.840,
3617.90625,2487.598,4696.47803,2879.840,
3617.99756,2487.598,4696.56934,2879.840,
3618.08911,2488.598,4696.66113,2880.840,
3618.18066,2488.598,4696.75244,2879.840,
3618.27222,2488.598,4696.84424,2879.840,
3618.36377,2488.598,4696.93555,2879.840,
3618.45532,2488.598,4697.02734,2880.840,
3618.54688,2488.598,4697.11865,2879.840,
3618.63843,2489.598,4697.20996,2879.840,
3618.72974,2489.598,4697.30176,2879.840,
3618.82129,2489.598,4697.39307,2880.840,
3618.91284,2489.598,4697.48486,2879.840,
3619.00439,2490.598,4697.57617,2880.840,
3619.09595,2490.598,4697.66797,2879.840,
3619.18750,2490.598,4697.75928,2880.840,
3619.27905,2491.598,4697.85059,2879.840,
3619.37036,2490.598,4697.94238,2879.840,
3619.46191,2491.598,4698.03369,2879.840,
3619.55347,2491.598,4698.12549,2879.840,
3619.64502,2491.598,4698.21680,2879.840,
3619.73657,2491.598,4698.30859,2879.840,
3619.82813,2492.598,4698.39990,2879.840,
3619.91968,2491.598,4698.49121,2880.840,
3620.01123,2492.598,4698.58301,2879.840,
3620.10254,2492.598,4698.67432,2879.840,
3620.19409,2492.598,4698.76611,2879.840,
3620.28564,2492.598,4698.85742,2879.840,
3620.37720,2492.598,4698.94922,2879.840,
3620.46875,2493.598,4699.04053,2879.840,
3620.56030,2493.598,4699.13232,2879.840,
3620.65186,2493.598,4699.22363,2879.840,
3620.74316,2494.598,4699.31494,2879.840,
3620.83472,2494.598,4699.40674,2879.840,
3620.92627,2493.598,4699.49805,2879.840,
3621.01782,2493.598,4699.58984,2879.840,
3621.10938,2494.598,4699.68115,2879.840,
3621.20093,2494.598,4699.77295,2879.840,
3621.29248,2495.598,4699.86426,2879.840,
3621.38403,2495.598,4699.95557,2880.840,
3621.47534,2495.598,4700.04736,2879.840,
3621.56689,2495.598,4700.13867,2879.840,
3621.65845,2495.598,4700.23047,2879.840,
3621.75000,2496.598,4700.32178,2879.840,
3621.84155,2496.598,4700.41357,2879.840,
3621.93311,2496.598,4700.50488,2879.840,
3622.02466,2496.598,4700.59619,2879.840,
3622.11621,2497.598,4700.68799,2879.840,
3622.20752,2497.598,4700.77930,2879.840,
3622.29907,2497.598,4700.87109,2879.840,
3622.39063,2497.598,4700.96240,2879.840,
3622.48218,2497.598,4701.05420,2878.840,
3622.57373,2498.598,4701.14551,2880.840,
3622.66528,2498.598,4701.23730,2879.840,
3622.75684,2498.598,4701.32861,2879.840,
3622.84814,2498.598,4701.41992,2879.840,
3622.93970,2499.598,4701.51172,2879.840,
3623.03125,2498.598,4701.60303,2879.840,
3623.12280,2499.598,4701.69482,2879.840,
3623.21436,2499.598,4701.78613,2879.840,
3623.30591,2499.598,4701.87793,2879.840,
3623.39746,2499.598,4701.96924,2879.840,
3623.48901,2500.598,4702.06055,2879.840,
3623.58032,2499.598,4702.15234,2879.840,
3623.67188,2500.598,4702.24365,2879.840,
3623.76343,2500.598,4702.33545,2879.840,
3623.85498,2501.598,4702.42676,2879.840,
3623.94653,2501.598,4702.51855,2879.840,
3624.03809,2501.598,4702.60986,2879.840,
3624.12964,2502.598,4702.70117,2879.840,
3624.22119,2502.598,4702.79297,2879.840,
3624.31250,2502.598,4702.88428,2879.840,
3624.40405,2502.598,4702.97607,2879.840,
3624.49561,2503.598,4703.06738,2879.840,
3624.58716,2502.598,4703.15918,2878.840,
3624.67871,2503.598,4703.25049,2879.840,
3624.77026,2503.598,4703.34229,2879.840,
3624.86182,2503.598,4703.43359,2878.840,
3624.95313,2503.598,4703.52490,2878.840,
3625.04468,2504.598,4703.61670,2879.840,
3625.13623,2504.598,4703.70801,2879.840,
3625.22778,2504.598,4703.79980,2879.840,
3625.31934,2505.598,4703.89111,2878.840,
3625.41089,2505.598,4703.98291,2879.840,
3625.50244,2505.598,4704.07422,2878.840,
3625.59399,2504.598,4704.16553,2879.840,
3625.68530,2505.598,4704.25732,2878.840,
3625.77686,2505.598,4704.34863,2879.840,
3625.86841,2505.598,4704.44043,2879.840,
3625.95996,2505.598,4704.53174,2879.840,
3626.05151,2505.598,4704.62354,2879.840,
3626.14307,2506.598,4704.71484,2879.840,
3626.23462,2505.598,4704.80615,2879.840,
3626.32593,2506.598,4704.89795,2879.840,
3626.41748,2507.598,4704.98926,2879.840,
3626.50903,2506.598,4705.08105,2878.840,
3626.60059,2507.598,4705.17236,2878.840,
3626.69214,2508.598,4705.26416,2878.840,
3626.78369,2508.598,4705.35547,2878.840,
3626.87524,2508.598,4705.44727,2878.840,
3626.96680,2509.598,4705.53857,2878.840,
3627.05811,2509.598,4705.62988,2878.840,
3627.14966,2508.598,4705.72168,2878.840,
3627.24121,2509.598,4705.81299,2878.840,
3627.33276,2509.598,4705.90479,2878.840,
3627.42432,2509.598,4705.99609,2879.840,
3627.51587,2509.598,4706.08789,2878.840,
3627.60742,2509.598,4706.17920,2879.840,
3627.69897,2509.598,4706.27051,2878.840,
3627.79028,2509.598,4706.36230,2878.840,
3627.88184,2510.598,4706.45361,2878.840,
3627.97339,2510.598,4706.54541,2878.840,
3628.06494,2510.598,4706.63672,2878.840,
3628.15649,2510.598,4706.72852,2878.840,
3628.24805,2510.598,4706.81982,2878.840,
3628.33960,2510.598,4706.91113,2878.840,
3628.43091,2511.598,4707.00293,2879.840,
3628.52246,2511.598,4707.09424,2878.840,
3628.61401,2511.598,4707.18604,2878.840,
3628.70557,2511.598,4707.27734,2878.840,
3628.79712,2512.598,4707.36914,2878.840,
3628.88867,2512.598,4707.46045,2878.840,
3628.98022,2511.598,4707.55176,2877.840,
3629.07178,2512.598,4707.64355,2878.840,
3629.16309,2512.598,4707.73486,2878.840,
3629.25464,2512.598,4707.82666,2878.840,
3629.34619,2512.598,4707.91797,2877.840,
3629.43774,2513.598,4708.00977,2878.840,
3629.52930,2513.598,4708.10107,2878.840,
3629.62085,2513.598,4708.19287,2878.840,
3629.71240,2514.598,4708.28418,2878.840,
3629.80396,2513.598,4708.37549,2878.840,
3629.89526,2514.598,4708.46729,2877.840,
3629.98682,2514.598,4708.55859,2878.840,
3630.07837,2514.598,4708.65039,2877.840,
3630.16992,2514.598,4708.74170,2878.840,
3630.26147,2515.598,4708.83350,2877.840,
3630.35303,2514.598,4708.92480,2878.840,
3630.44458,2515.598,4709.01611,2878.840,
3630.53589,2515.598,4709.10791,2877.840,
3630.62744,2515.598,4709.19922,2877.840,
3630.71899,2515.598,4709.29102,2877.840,
3630.81055,2516.598,4709.38232,2877.840,
3630.90210,2516.598,4709.47412,2877.840,
3630.99365,2517.598,4709.56543,2877.840,
3631.08521,2517.598,4709.65674,2877.840,
3631.17676,2517.598,4709.74854,2877.840,
3631.26807,2517.598,4709.83984,2877.840,
3631.35962,2517.598,4709.93164,2876.840,
3631.45117,2517.598,4710.02295,2877.840,
3631.54272,2517.598,4710.11475,2877.840,
3631.63428,2518.598,4710.20605,2878.840,
3631.72583,2518.598,4710.29785,2877.840,
3631.81738,2518.598,4710.38916,2877.840,
3631.90869,2518.598,4710.48047,2877.840,
3632.00024,2518.598,4710.57227,2877.840,
3632.09180,2519.598,4710.66357,2876.840,
3632.18335,2519.598,4710.75537,2877.840,
3632.27490,2519.598,4710.84668,2877.840,
3632.36646,2519.598,4710.93848,2877.840,
3632.45801,2520.598,4711.02979,2878.840,
3632.54956,2520.598,4711.12109,2877.840,
3632.64087,2520.598,4711.21289,2877.840,
3632.73242,2520.598,4711.30420,2877.840,
3632.82397,2520.598,4711.39600,2878.840,
3632.91553,2520.598,4711.48730,2878.840,
3633.00708,2521.598,4711.57910,2877.840,
3633.09863,2521.598,4711.67041,2878.840,
3633.19019,2521.598,4711.76172,2877.840,
3633.28174,2521.598,4711.85352,2877.840,
3633.37305,2521.598,4711.94482,2877.840,
3633.46460,2521.598,4712.03662,2877.840,
3633.55615,2522.598,4712.12793,2878.840,
3633.64771,2522.598,4712.21973,2877.840,
3633.73926,2522.598,4712.31104,2877.840,
3633.83081,2522.598,4712.40283,2877.840,
3633.92236,2523.598,4712.49414,2877.840,
3634.01367,2523.598,4712.58545,2877.840,
3634.10522,2523.598,4712.67725,2876.840,
3634.19678,2523.598,4712.76855,2877.840,
3634.28833,2523.598,4712.86035,2877.840,
3634.37988,2523.598,4712.95166,2876.840,
3634.47144,2524.598,4713.04346,2876.840,
3634.56299,2524.598,4713.13477,2877.840,
3634.65454,2524.598,4713.22607,2877.840,
3634.74585,2524.598,4713.31787,2877.840,
3634.83740,2524.598,4713.40918,2877.840,
3634.92896,2524.598,4713.50098,2877.840,
3635.02051,2525.598,4713.59229,2878.840,
3635.11206,2525.598,4713.68408,2878.840,
3635.20361,2526.598,4713.77539,2878.840,
3635.29517,2526.598,4713.86670,2878.840,
3635.38672,2527.598,4713.95850,2878.840,
3635.47803,2526.598,4714.04980,2878.840,
3635.56958,2526.598,4714.14160,2878.840,
3635.66113,2526.598,4714.23291,2878.840,
3635.75269,2526.598,4714.32471,2877.840,
3635.84424,2526.598,4714.41602,2877.840,
3635.93579,2527.598,4714.50781,2877.840,
3636.02734,2527.598,4714.59912,2878.840,
3636.11865,2527.598,4714.69043,2877.840,
3636.21021,2527.598,4714.78223,2877.840,
3636.30176,2528.598,4714.87354,2877.840,
3636.39331,2528.598,4714.96533,2876.840,
3636.48486,2528.598,4715.05664,2876.840,
3636.57642,2528.598,4715.14844,2876.840,
3636.66797,2529.598,4715.23975,2876.840,
3636.75952,2529.598,4715.33105,2876.840,
3636.85083,2529.598,4715.42285,2876.840,
3636.94238,2529.598,4715.51416,2876.840,
3637.03394,2529.598,4715.60596,2876.840,
3637.12549,2529.598,4715.69727,2876.840,
3637.21704,2530.598,4715.78906,2876.840,
3637.30859,2530.598,4715.88037,2876.840,
3637.40015,2530.598,4715.97168,2876.840,
3637.49170,2531.598,4716.06348,2876.840,
3637.58301,2531.598,4716.15479,2876.840,
3637.67456,2530.598,4716.24658,2876.840,
3637.76611,2531.598,4716.33789,2876.840,
3637.85767,2531.598,4716.42969,2876.840,
3637.94922,2531.598,4716.52100,2875.840,
3638.04077,2531.598,4716.61279,2876.840,
3638.13232,2531.598,4716.70410,2876.840,
3638.22363,2531.598,4716.79541,2875.840,
3638.31519,2533.598,4716.88721,2876.840,
3638.40674,2532.598,4716.97852,2875.840,
3638.49829,2532.598,4717.07031,2875.840,
3638.58984,2533.598,4717.16162,2875.840,
3638.68140,2533.598,4717.25342,2876.840,
3638.77295,2533.598,4717.34473,2875.840,
3638.86450,2533.598,4717.43604,2876.840,
3638.95581,2534.598,4717.52783,2876.840,
3639.04736,2534.598,4717.61914,2875.840,
3639.13892,2534.598,4717.71094,2875.840,
3639.23047,2534.598,4717.80225,2876.840,
3639.32202,2535.598,4717.89404,2875.840,
3639.41357,2534.598,4717.98535,2875.840,
3639.50513,2535.598,4718.07666,2875.840,
3639.59644,2535.598,4718.16846,2875.840,
3639.68799,2535.598,4718.25977,2875.840,
3639.77954,2536.598,4718.35156,2875.840,
3639.87109,2536.598,4718.44287,2875.840,
3639.96265,2535.598,4718.53467,2875.840,
3640.05420,2535.598,4718.62598,2875.840,
3640.14575,2536.598,4718.71777,2875.840,
3640.23730,2537.598,4718.80908,2875.840,
3640.32861,2537.598,4718.90039,2875.840,
3640.42017,2536.598,4718.99219,2876.840,
3640.51172,2537.598,4719.08350,2875.840,
3640.60327,2537.598,4719.17529,2875.840,
3640.69482,2538.598,4719.26660,2875.840,
3640.78638,2537.598,4719.35840,2875.840,
3640.87793,2537.598,4719.44971,2875.840,
3640.96948,2538.598,4719.54102,2875.840,
3641.06079,2538.598,4719.63281,2875.840,
3641.15234,2538.598,4719.72412,2875.840,
3641.24390,2539.598,4719.81592,2875.840,
3641.33545,2538.598,4719.90723,2875.840,
3641.42700,2539.598,4719.99902,2875.840,
3641.51855,2539.598,4720.09033,2874.840,
3641.61011,2539.598,4720.18164,2874.840,
3641.70142,2540.598,4720.27344,2874.840,
3641.79297,2539.598,4720.36475,2874.840,
3641.88452,2540.598,4720.45654,2874.840,
3641.97607,2540.598,4720.54785,2875.840,
3642.06763,2540.598,4720.63965,2875.840,
3642.15918,2540.598,4720.73096,2874.840,
3642.25073,2541.598,4720.82227,2874.840,
3642.34229,2540.598,4720.91406,2874.840,
3642.43359,2541.598,4721.00537,2874.840,
3642.52515,2541.598,4721.09717,2875.840,
3642.61670,2541.598,4721.18848,2874.840,
3642.70825,2542.598,4721.28027,2874.840,
3642.79980,2541.598,4721.37158,2874.840,
3642.89136,2542.598,4721.46338,2874.840,
3642.98291,2542.598,4721.55469,2874.840,
3643.07446,2542.598,4721.64600,2874.840,
3643.16577,2543.598,4721.73779,2874.840,
3643.25732,2543.598,4721.82910,2874.840,
3643.34888,2543.598,4721.92090,2875.840,
3643.44043,2543.598,4722.01221,2874.840,
3643.53198,2543.598,4722.10400,2874.840,
3643.62354,2543.598,4722.19531,2874.840,
3643.71509,2543.598,4722.28662,2875.840,
3643.80640,2543.598,4722.37842,2874.840,
3643.89795,2543.598,4722.46973,2874.840,
3643.98950,2544.598,4722.56152,2874.840,
3644.08105,2545.598,4722.65283,2874.840,
3644.17261,2545.598,4722.74463,2874.840,
3644.26416,2544.598,4722.83594,2874.840,
3644.35571,2545.598,4722.92725,2874.840,
3644.44727,2545.598,4723.01904,2874.840,
3644.53857,2546.598,4723.11035,2874.840,
3644.63013,2545.598,4723.20215,2874.840,
3644.72168,2545.598,4723.29346,2874.840,
3644.81323,2546.598,4723.38525,2874.840,
3644.90479,2547.598,4723.47656,2874.840,
3644.99634,2546.598,4723.56836,2874.840,
3645.08789,2547.598,4723.65967,2874.840,
3645.17920,2546.598,4723.75098,2874.840,
3645.27075,2547.598,4723.84277,2873.840,
3645.36230,2547.598,4723.93408,2873.840,
3645.45386,2547.598,4724.02588,2874.840,
3645.54541,2548.598,4724.11719,2873.840,
3645.63696,2548.598,4724.20898,2873.840,
3645.72852,2548.598,4724.30029,2873.840,
3645.82007,2548.598,4724.39160,2873.840,
3645.91138,2548.598,4724.48340,2873.840,
3646.00293,2548.598,4724.57471,2873.840,
3646.09448,2549.598,4724.66650,2873.840,
3646.18604,2549.598,4724.75781,2873.840,
3646.27759,2548.598,4724.84961,2874.840,
3646.36914,2550.598,4724.94092,2873.840,
3646.46069,2549.598,4725.03223,2873.840,
3646.55225,2549.598,4725.12402,2873.840,
3646.64355,2550.598,4725.21533,2873.840,
3646.73511,2551.598,4725.30713,2873.840,
3646.82666,2552.598,4725.39844,2873.840,
3646.91821,2552.598,4725.49023,2873.840,
3647.00977,2553.598,4725.58154,2872.840,
3647.10132,2554.598,4725.67334,2873.840,
3647.19287,2554.598,4725.76465,2873.840,
3647.28418,2554.598,4725.85596,2872.840,
3647.37573,2554.598,4725.94775,2872.840,
3647.46729,2554.598,4726.03906,2872.840,
3647.55884,2555.598,4726.13086,2872.840,
3647.65039,2555.598,4726.22217,2872.840,
3647.74194,2555.598,4726.31396,2873.840,
3647.83350,2554.598,4726.40527,2872.840,
3647.92505,2554.598,4726.49658,2873.840,
3648.01636,2554.598,4726.58838,2872.840,
3648.10791,2554.598,4726.67969,2873.840,
3648.19946,2554.598,4726.77148,2873.840,
3648.29102,2554.598,4726.86279,2873.840,
3648.38257,2554.598,4726.95459,2872.840,
3648.47412,2554.598,4727.04590,2873.840,
3648.56567,2555.598,4727.13721,2872.840,
3648.65723,2555.598,4727.22900,2872.840,
3648.74854,2555.598,4727.32031,2872.840,
3648.84009,2555.598,4727.41211,2872.840,
3648.93164,2556.598,4727.50342,2872.840,
3649.02319,2556.598,4727.59521,2872.840,
3649.11475,2557.598,4727.68652,2872.840,
3649.20630,2558.598,4727.77832,2873.840,
3649.29785,2559.598,4727.86963,2872.840,
3649.38916,2560.598,4727.96094,2872.840,
3649.48071,2560.598,4728.05273,2872.840,
3649.57227,2560.598,4728.14404,2872.840,
3649.66382,2560.598,4728.23584,2872.840,
3649.75537,2560.598,4728.32715,2871.840,
3649.84692,2560.598,4728.41895,2872.840,
3649.93848,2559.598,4728.51025,2872.840,
3650.03003,2560.598,4728.60156,2872.840,
3650.12134,2559.598,4728.69336,2871.840,
3650.21289,2559.598,4728.78467,2872.840,
3650.30444,2559.598,4728.87646,2872.840,
3650.39600,2559.598,4728.96777,2871.840,
3650.48755,2559.598,4729.05957,2872.840,
3650.57910,2559.598,4729.15088,2871.840,
3650.67065,2559.598,4729.24219,2872.840,
3650.76196,2559.598,4729.33398,2872.840,
3650.85352,2559.598,4729.42529,2872.840,
3650.94507,2559.598,4729.51709,2871.840,
3651.03662,2560.598,4729.60840,2871.840,
3651.12817,2560.598,4729.70020,2871.840,
3651.21973,2560.598,4729.79150,2871.840,
3651.31128,2560.598,4729.88330,2871.840,
3651.40283,2560.598,4729.97461,2871.840,
3651.49414,2561.598,4730.06592,2871.840,
3651.58569,2560.598,4730.15771,2871.840,
3651.67725,2560.598,4730.24902,2871.840,
3651.76880,2561.598,4730.34082,2871.840,
3651.86035,2561.598,4730.43213,2871.840,
3651.95190,2561.598,4730.52393,2871.840,
3652.04346,2561.598,4730.61523,2871.840,
3652.13501,2562.598,4730.70654,2872.840,
3652.22632,2562.598,4730.79834,2871.840,
3652.31787,2562.598,4730.88965,2871.840,
3652.40942,2562.598,4730.98145,2871.840,
3652.50098,2562.598,4731.07275,2871.840,
3652.59253,2563.598,4731.16455,2871.840,
3652.68408,2563.598,4731.25586,2871.840,
3652.77563,2563.598,4731.34717,2870.840,
3652.86694,2563.598,4731.43896,2870.840,
3652.95850,2564.598,4731.53027,2870.840,
3653.05005,2563.598,4731.62207,2870.840,
3653.14160,2564.598,4731.71338,2870.840,
3653.23315,2564.598,4731.80518,2870.840,
3653.32471,2564.598,4731.89648,2869.840,
3653.41626,2564.598,4731.98828,2870.840,
3653.50781,2565.598,4732.07959,2870.840,
3653.59912,2565.598,4732.17090,2870.840,
3653.69067,2565.598,4732.26270,2870.840,
3653.78223,2565.598,4732.35400,2870.840,
3653.87378,2565.598,4732.44580,2869.840,
3653.96533,2565.598,4732.53711,2870.840,
3654.05688,2565.598,4732.62891,2870.840,
3654.14844,2565.598,4732.72021,2870.840,
3654.23999,2565.598,4732.81152,2870.840,
3654.33130,2566.598,4732.90332,2870.840,
3654.42285,2567.598,4732.99463,2870.840,
3654.51440,2566.598,4733.08643,2870.840,
3654.60596,2566.598,4733.17773,2869.840,
3654.69751,2567.598,4733.26953,2870.840,
3654.78906,2567.598,4733.36084,2870.840,
3654.88062,2567.598,4733.45215,2869.840,
3654.97192,2567.598,4733.54395,2870.840,
3655.06348,2567.598,4733.63525,2870.840,
3655.15503,2568.598,4733.72705,2870.840,
3655.24658,2568.598,4733.81836,2871.840,
3655.33813,2568.598,4733.91016,2871.840,
3655.42969,2568.598,4734.00146,2872.840,
3655.52124,2568.598,4734.09277,2873.840,
3655.61279,2569.598,4734.18457,2872.840,
3655.70410,2569.598,4734.27588,2872.840,
3655.79565,2569.598,4734.36768,2872.840,
3655.88721,2570.598,4734.45898,2872.840,
3655.97876,2569.598,4734.55078,2872.840,
3656.07031,2569.598,4734.64209,2871.840,
3656.16187,2570.598,4734.73389,2871.840,
3656.25342,2570.598,4734.82520,2870.840,
3656.34497,2570.598,4734.91650,2870.840,
3656.43628,2570.598,4735.00830,2870.840,
3656.52783,2571.598,4735.09961,2870.840,
3656.61938,2571.598,4735.19141,2869.840,
3656.71094,2571.598,4735.28271,2869.840,
3656.80249,2571.598,4735.37451,2869.840,
3656.89404,2571.598,4735.46582,2869.840,
3656.98560,2572.598,4735.55713,2868.840,
3657.07690,2572.598,4735.64893,2868.840,
3657.16846,2572.598,4735.74023,2868.840,
3657.26001,2572.598,4735.83203,2868.840,
3657.35156,2573.598,4735.92334,2869.840,
3657.44312,2573.598,4736.01514,2868.840,
3657.53467,2573.598,4736.10645,2868.840,
3657.62622,2573.598,4736.19775,2868.840,
3657.71777,2573.598,4736.28955,2868.840,
3657.80908,2574.598,4736.38086,2868.840,
3657.90063,2573.598,4736.47266,2869.840,
3657.99219,2574.598,4736.56396,2869.840,
3658.08374,2574.598,4736.65576,2868.840,
3658.17529,2575.598,4736.74707,2868.840,
3658.26685,2575.598,4736.83887,2868.840,
3658.35840,2575.598,4736.93018,2868.840,
3658.44971,2574.598,4737.02148,2868.840,
3658.54126,2575.598,4737.11328,2868.840,
3658.63281,2575.598,4737.20459,2868.840,
3658.72437,2575.598,4737.29639,2868.840,
3658.81592,2576.598,4737.38770,2868.840,
3658.90747,2576.598,4737.47949,2868.840,
3658.99902,2576.598,4737.57080,2868.840,
3659.09058,2576.598,4737.66211,2868.840,
3659.18188,2576.598,4737.75391,2867.840,
3659.27344,2577.598,4737.84521,2868.840,
3659.36499,2577.598,4737.93701,2867.840,
3659.45654,2577.598,4738.02832,2868.840,
3659.54810,2577.598,4738.12012,2867.840,
3659.63965,2577.598,4738.21143,2868.840,
3659.73120,2577.598,4738.30273,2867.840,
3659.82275,2577.598,4738.39453,2867.840,
3659.91406,2578.598,4738.48584,2867.840,
3660.00562,2578.598,4738.57764,2867.840,
3660.09717,2578.598,4738.66895,2867.840,
3660.18872,2578.598,4738.76074,2867.840,
3660.28027,2579.598,4738.85205,2866.840,
3660.37183,2579.598,4738.94385,2867.840,
3660.46338,2579.598,4739.03516,2866.840,
3660.55469,2579.598,4739.12646,2867.840,
3660.64624,2579.598,4739.21826,2866.840,
3660.73779,2579.598,4739.30957,2866.840,
3660.82935,2579.598,4739.40137,2866.840,
3660.92090,2580.598,4739.49268,2867.840,
3661.01245,2580.598,4739.58447,2866.840,
3661.10400,2580.598,4739.67578,2866.840,
3661.19556,2581.598,4739.76709,2866.840,
3661.28687,2580.598,4739.85889,2866.840,
3661.37842,2580.598,4739.95020,2866.840,
3661.46997,2581.598,4740.04199,2866.840,
3661.56152,2581.598,4740.13330,2866.840,
3661.65308,2581.598,4740.22510,2866.840,
3661.74463,2582.598,4740.31641,2866.840,
3661.83618,2582.598,4740.40771,2866.840,
3661.92773,2582.598,4740.49951,2866.840,
3662.01904,2582.598,4740.59082,2866.840,
3662.11060,2583.598,4740.68262,2866.840,
3662.20215,2583.598,4740.77393,2866.840,
3662.29370,2582.598,4740.86572,2866.840,
3662.38525,2583.598,4740.95703,2866.840,
3662.47681,2583.598,4741.04883,2866.840,
3662.56836,2583.598,4741.14014,2865.840,
3662.65967,2584.598,4741.23145,2865.840,
3662.75122,2584.598,4741.32324,2866.840,
3662.84277,2583.598,4741.41455,2866.840,
3662.93433,2584.598,4741.50635,2865.840,
3663.02588,2584.598,4741.59766,2865.840,
3663.11743,2584.598,4741.68945,2865.840,
3663.20898,2585.598,4741.78076,2865.840,
3663.30054,2585.598,4741.87207,2865.840,
3663.39185,2585.598,4741.96387,2865.840,
3663.48340,2585.598,4742.05518,2865.840,
3663.57495,2586.598,4742.14697,2866.840,
3663.66650,2585.598,4742.23828,2865.840,
3663.75806,2585.598,4742.33008,2865.840,
3663.84961,2585.598,4742.42139,2866.840,
3663.94116,2586.598,4742.51270,2865.840,
3664.03247,2586.598,4742.60449,2865.840,
3664.12402,2586.598,4742.69580,2865.840,
3664.21558,2587.598,4742.78760,2865.840,
3664.30713,2586.598,4742.87891,2865.840,
3664.39868,2587.598,4742.97070,2865.840,
3664.49023,2587.598,4743.06201,2865.840,
3664.58179,2587.598,4743.15381,2865.840,
3664.67334,2588.598,4743.24512,2865.840,
3664.76465,2588.598,4743.33643,2865.840,
3664.85620,2588.598,4743.42822,2864.840,
3664.94775,2588.598,4743.51953,2864.840,
3665.03931,2589.598,4743.61133,2865.840,
3665.13086,2588.598,4743.70264,2864.840,
3665.22241,2589.598,4743.79443,2864.840,
3665.31396,2588.598,4743.88574,2865.840,
3665.40552,2589.598,4743.97705,2864.840,
3665.49683,2589.598,4744.06885,2864.840,
3665.58838,2589.598,4744.16016,2864.840,
3665.67993,2589.598,4744.25195,2864.840,
3665.77148,2589.598,4744.34326,2864.840,
3665.86304,2590.598,4744.43506,2864.840,
3665.95459,2590.598,4744.52637,2864.840,
3666.04614,2590.598,4744.61768,2864.840,
3666.13745,2591.598,4744.70947,2864.840,
3666.22900,2590.598,4744.80078,2864.840,
3666.32056,2591.598,4744.89258,2864.840,
3666.41211,2591.598,4744.98389,2864.840,
3666.50366,2591.598,4745.07568,2863.840,
3666.59521,2591.598,4745.16699,2864.840,
3666.68677,2591.598,4745.25830,2863.840,
3666.77832,2591.598,4745.35010,2864.840,
3666.86963,2592.598,4745.44141,2864.840,
3666.96118,2591.598,4745.53320,2864.840,
3667.05273,2592.598,4745.62451,2864.840,
3667.14429,2592.598,4745.71631,2863.840,
3667.23584,2592.598,4745.80762,2863.840,
3667.32739,2592.598,4745.89941,2863.840,
3667.41895,2592.598,4745.99072,2863.840,
3667.51050,2593.598,4746.08203,2863.840,
3667.60181,2594.598,4746.17383,2863.840,
3667.69336,2593.598,4746.26514,2864.840,
3667.78491,2594.598,4746.35693,2863.840,
3667.87646,2594.598,4746.44824,2862.840,
3667.96802,2594.598,4746.54004,2863.840,
3668.05957,2594.598,4746.63135,2863.840,
3668.15112,2595.598,4746.72266,2863.840,
3668.24243,2595.598,4746.81445,2863.840,
3668.33398,2595.598,4746.90576,2863.840,
3668.42554,2595.598,4746.99756,2863.840,
3668.51709,2595.598,4747.08887,2863.840,
3668.60864,2595.598,4747.18066,2863.840,
3668.70020,2596.598,4747.27197,2862.840,
3668.79175,2595.598,4747.36328,2863.840,
3668.88330,2596.598,4747.45508,2862.840,
3668.97461,2596.598,4747.54639,2862.840,
3669.06616,2596.598,4747.63818,2862.840,
3669.15771,2597.598,4747.72949,2862.840,
3669.24927,2597.598,4747.82129,2862.840,
3669.34082,2598.598,4747.91260,2862.840,
3669.43237,2598.598,4748.00439,2862.840,
3669.52393,2599.598,4748.09570,2862.840,
3669.61523,2599.598,4748.18701,2862.840,
3669.70679,2599.598,4748.27881,2863.840,
3669.79834,2599.598,4748.37012,2862.840,
3669.88989,2599.598,4748.46191,2862.840,
3669.98145,2599.598,4748.55322,2862.840,
3670.07300,2598.598,4748.64502,2862.840,
3670.16455,2599.598,4748.73633,2861.840,
3670.25610,2599.598,4748.82764,2861.840,
3670.34741,2599.598,4748.91943,2862.840,
3670.43896,2599.598,4749.01074,2861.840,
3670.53052,2600.598,4749.10254,2861.840,
3670.62207,2599.598,4749.19385,2861.840,
3670.71362,2600.598,4749.28564,2861.840,
3670.80518,2600.598,4749.37695,2861.840,
3670.89673,2600.598,4749.46826,2861.840,
3670.98828,2601.598,4749.56006,2860.840,
3671.07959,2600.598,4749.65137,2861.840,
3671.17114,2600.598,4749.74316,2861.840,
3671.26270,2601.598,4749.83447,2860.840,
3671.35425,2601.598,4749.92627,2861.840,
3671.44580,2601.598,4750.01758,2860.840,
3671.53735,2601.598,4750.10938,2860.840,
3671.62891,2602.598,4750.20068,2861.840,
3671.72021,2602.598,4750.29199,2860.840,
3671.81177,2602.598,4750.38379,2861.840,
3671.90332,2603.598,4750.47510,2860.840,
3671.99487,2604.598,4750.56689,2860.840,
3672.08643,2603.598,4750.65820,2861.840,
3672.17798,2603.598,4750.75000,2860.840,
3672.26953,2604.598,4750.84131,2860.840,
3672.36108,2603.598,4750.93262,2860.840,
3672.45239,2604.598,4751.02441,2860.840,
3672.54395,2604.598,4751.11572,2860.840,
3672.63550,2604.598,4751.20752,2860.840,
3672.72705,2604.598,4751.29883,2860.840,
3672.81860,2604.598,4751.39063,2860.840,
3672.91016,2604.598,4751.48193,2860.840,
3673.00171,2605.598,4751.57324,2861.840,
3673.09326,2605.598,4751.66504,2860.840,
3673.18457,2605.598,4751.75635,2861.840,
3673.27612,2605.598,4751.84814,2861.840,
3673.36768,2606.598,4751.93945,2861.840,
3673.45923,2606.598,4752.03125,2861.840,
3673.55078,2606.598,4752.12256,2862.840,
3673.64233,2606.598,4752.21436,2862.840,
3673.73389,2606.598,4752.30566,2861.840,
3673.82520,2606.598,4752.39697,2861.840,
3673.91675,2606.598,4752.48877,2862.840,
3674.00830,2606.598,4752.58008,2861.840,
3674.09985,2607.598,4752.67188,2861.840,
3674.19141,2607.598,4752.76318,2861.840,
3674.28296,2607.598,4752.85498,2860.840,
3674.37451,2607.598,4752.94629,2860.840,
3674.46606,2607.598,4753.03760,2859.840,
3674.55737,2607.598,4753.12939,2859.840,
3674.64893,2607.598,4753.22070,2859.840,
3674.74048,2607.598,4753.31250,2859.840,
3674.83203,2607.598,4753.40381,2859.840,
3674.92358,2608.598,4753.49561,2859.840,
3675.01514,2608.598,4753.58691,2859.840,
3675.10669,2608.598,4753.67822,2858.840,
3675.19824,2608.598,4753.77002,2859.840,
3675.28955,2609.598,4753.86133,2859.840,
3675.38110,2608.598,4753.95313,2860.840,
3675.47266,2609.598,4754.04443,2860.840,
3675.56421,2609.598,4754.13623,2861.840,
3675.65576,2608.598,4754.22754,2861.840,
3675.74731,2609.598,4754.31934,2861.840,
3675.83887,2610.598,4754.41064,2861.840,
3675.93018,2610.598,4754.50195,2860.840,
3676.02173,2610.598,4754.59375,2860.840,
3676.11328,2610.598,4754.68506,2859.840,
3676.20483,2610.598,4754.77686,2859.840,
3676.29639,2610.598,4754.86816,2859.840,
3676.38794,2611.598,4754.95996,2858.840,
3676.47949,2610.598,4755.05127,2857.840,
3676.57104,2610.598,4755.14258,2858.840,
3676.66235,2611.598,4755.23438,2857.840,
3676.75391,2611.598,4755.32568,2857.840,
3676.84546,2611.598,4755.41748,2857.840,
3676.93701,2612.598,4755.50879,2857.840,
3677.02856,2612.598,4755.60059,2857.840,
3677.12012,2611.598,4755.69189,2857.840,
3677.21167,2612.598,4755.78320,2857.840,
3677.30298,2613.598,4755.87500,2857.840,
3677.39453,2612.598,4755.96631,2857.840,
3677.48608,2613.598,4756.05811,2857.840,
3677.57764,2613.598,4756.14941,2856.840,
3677.66919,2613.598,4756.24121,2857.840,
3677.76074,2613.598,4756.33252,2857.840,
3677.85229,2614.598,4756.42432,2856.840,
3677.94385,2614.598,4756.51563,2857.840,
3678.03516,2614.598,4756.60693,2856.840,
3678.12671,2614.598,4756.69873,2856.840,
3678.21826,2615.598,4756.79004,2856.840,
3678.30981,2615.598,4756.88184,2857.840,
3678.40137,2615.598,4756.97314,2856.840,
3678.49292,2615.598,4757.06494,2857.840,
3678.58447,2615.598,4757.15625,2856.840,
3678.67603,2615.598,4757.24756,2856.840,
3678.76733,2616.598,4757.33936,2856.840,
3678.85889,2616.598,4757.43066,2856.840,
3678.95044,2615.598,4757.52246,2856.840,
3679.04199,2616.598,4757.61377,2856.840,
3679.13354,2616.598,4757.70557,2856.840,
3679.22510,2616.598,4757.79688,2856.840,
3679.31665,2617.598,4757.88818,2856.840,
3679.40796,2617.598,4757.97998,2856.840,
3679.49951,2617.598,4758.07129,2856.840,
3679.59106,2617.598,4758.16309,2856.840,
3679.68262,2617.598,4758.25439,2855.840,
3679.77417,2617.598,4758.34619,2856.840,
3679.86572,2618.598,4758.43750,2855.840,
3679.95728,2618.598,4758.52881,2856.840,
3680.04883,2618.598,4758.62061,2855.840,
3680.14014,2618.598,4758.71191,2856.840,
3680.23169,2618.598,4758.80371,2855.840,
3680.32324,2618.598,4758.89502,2855.840,
3680.41479,2619.598,4758.98682,2855.840,
3680.50635,2619.598,4759.07813,2855.840,
3680.59790,2619.598,4759.16992,2855.840,
3680.68945,2618.598,4759.26123,2854.840,
3680.78101,2620.598,4759.35254,2855.840,
3680.87231,2620.598,4759.44434,2855.840,
3680.96387,2619.598,4759.53564,2854.840,
3681.05542,2620.598,4759.62744,2855.840,
3681.14697,2620.598,4759.71875,2855.840,
3681.23853,2620.598,4759.81055,2854.840,
3681.33008,2620.598,4759.90186,2854.840,
3681.42163,2620.598,4759.99316,2855.840,
3681.51294,2621.598,4760.08496,2854.840,
3681.60449,2621.598,4760.17627,2854.840,
3681.69604,2621.598,4760.26807,2854.840,
3681.78760,2621.598,4760.35938,2854.840,
3681.87915,2622.598,4760.45117,2854.840,
3681.97070,2621.598,4760.54248,2854.840,
3682.06226,2622.598,4760.63379,2854.840,
3682.15381,2621.598,4760.72559,2854.840,
3682.24512,2623.598,4760.81689,2853.840,
3682.33667,2622.598,4760.90869,2853.840,
3682.42822,2622.598,4761.00000,2853.840,
3682.51978,2622.598,4761.09180,2853.840,
3682.61133,2622.598,4761.18311,2853.840,
3682.70288,2623.598,4761.27490,2853.840,
3682.79443,2623.598,4761.36621,2853.840,
3682.88574,2624.598,4761.45752,2853.840,
3682.97729,2623.598,4761.54932,2853.840,
3683.06885,2623.598,4761.64063,2853.840,
3683.16040,2623.598,4761.73242,2853.840,
3683.25195,2624.598,4761.82373,2853.840,
3683.34351,2624.598,4761.91553,2852.840,
3683.43506,2624.598,4762.00684,2853.840,
3683.52661,2624.598,4762.09814,2852.840,
3683.61792,2625.598,4762.18994,2852.840,
3683.70947,2625.598,4762.28125,2852.840,
3683.80103,2625.598,4762.37305,2852.840,
3683.89258,2626.598,4762.46436,2852.840,
3683.98413,2625.598,4762.55615,2852.840,
3684.07568,2625.598,4762.64746,2852.840,
3684.16724,2626.598,4762.73877,2852.840,
3684.25879,2626.598,4762.83057,2852.840,
3684.35010,2626.598,4762.92188,2853.840,
3684.44165,2626.598,4763.01367,2852.840,
3684.53320,2626.598,4763.10498,2852.840,
3684.62476,2626.598,4763.19678,2852.840,
3684.71631,2627.598,4763.28809,2852.840,
3684.80786,2627.598,4763.37988,2852.840,
3684.89941,2627.598,4763.47119,2852.840,
3684.99072,2627.598,4763.56250,2852.840,
3685.08228,2628.598,4763.65430,2852.840,
3685.17383,2628.598,4763.74561,2852.840,
3685.26538,2628.598,4763.83740,2852.840,
3685.35693,2628.598,4763.92871,2852.840,
3685.44849,2628.598,4764.02051,2851.840,
3685.54004,2628.598,4764.11182,2852.840,
3685.63159,2629.598,4764.20313,2851.840,
3685.72290,2629.598,4764.29492,2851.840,
3685.81445,2629.598,4764.38623,2852.840,
3685.90601,2629.598,4764.47803,2851.840,
3685.99756,2629.598,4764.56934,2851.840,
3686.08911,2630.598,4764.66113,2851.840,
3686.18066,2630.598,4764.75244,2851.840,
3686.27222,2630.598,4764.84375,2851.840,
3686.36377,2630.598,4764.93555,2851.840,
3686.45508,2630.598,4765.02686,2851.840,
3686.54663,2630.598,4765.11865,2851.840,
3686.63818,2631.598,4765.20996,2851.840,
3686.72974,2630.598,4765.30176,2851.840,
3686.82129,2631.598,4765.39307,2851.840,
3686.91284,2631.598,4765.48486,2851.840,
3687.00439,2631.598,4765.57617,2851.840,
3687.09570,2631.598,4765.66748,2850.840,
3687.18726,2631.598,4765.75928,2850.840,
3687.27881,2631.598,4765.85059,2851.840,
3687.37036,2632.598,4765.94238,2850.840,
3687.46191,2632.598,4766.03369,2850.840,
3687.55347,2632.598,4766.12549,2850.840,
3687.64502,2632.598,4766.21680,2850.840,
3687.73657,2632.598,4766.30811,2850.840,
3687.82788,2633.598,4766.39990,2850.840,
3687.91943,2633.598,4766.49121,2850.840,
3688.01099,2633.598,4766.58301,2850.840,
3688.10254,2634.598,4766.67432,2850.840,
3688.19409,2633.598,4766.76611,2850.840,
3688.28564,2634.598,4766.85742,2850.840,
3688.37720,2634.598,4766.94873,2849.840,
3688.46851,2634.598,4767.04053,2849.840,
3688.56006,2634.598,4767.13184,2849.840,
3688.65161,2634.598,4767.22363,2849.840,
3688.74316,2635.598,4767.31494,2849.840,
3688.83472,2634.598,4767.40674,2849.840,
3688.92627,2635.598,4767.49805,2849.840,
3689.01782,2635.598,4767.58984,2849.840,
3689.10938,2635.598,4767.68115,2849.840,
3689.20068,2636.598,4767.77246,2849.840,
3689.29224,2635.598,4767.86426,2849.840,
3689.38379,2636.598,4767.95557,2848.840,
3689.47534,2636.598,4768.04736,2849.840,
3689.56689,2637.598,4768.13867,2848.840,
3689.65845,2636.598,4768.23047,2848.840,
3689.75000,2637.598,4768.32178,2848.840,
3689.84155,2637.598,4768.41309,2848.840,
3689.93286,2637.598,4768.50488,2848.840,
3690.02441,2637.598,4768.59619,2848.840,
3690.11597,2637.598,4768.68799,2848.840,
3690.20752,2638.598,4768.77930,2849.840,
3690.29907,2638.598,4768.87109,2848.840,
3690.39063,2639.598,4768.96240,2848.840,
3690.48218,2639.598,4769.05371,2848.840,
3690.57349,2640.598,4769.14551,2847.840,
3690.66504,2640.598,4769.23682,2848.840,
3690.75659,2641.598,4769.32861,2848.840,
3690.84814,2641.598,4769.41992,2848.840,
3690.93970,2641.598,4769.51172,2847.840,
3691.03125,2642.598,4769.60303,2847.840,
3691.12280,2641.598,4769.69434,2847.840,
3691.21436,2641.598,4769.78613,2847.840,
3691.30566,2641.598,4769.87744,2848.840,
3691.39722,2641.598,4769.96924,2847.840,
3691.48877,2641.598,4770.06055,2847.840,
3691.58032,2641.598,4770.15234,2847.840,
3691.67188,2641.598,4770.24365,2847.840,
3691.76343,2641.598,4770.33545,2847.840,
3691.85498,2641.598,4770.42676,2847.840,
3691.94653,2641.598,4770.51807,2847.840,
3692.03784,2641.598,4770.60986,2847.840,
3692.12939,2641.598,4770.70117,2846.840,
3692.22095,2641.598,4770.79297,2846.840,
3692.31250,2641.598,4770.88428,2847.840,
3692.40405,2641.598,4770.97607,2846.840,
3692.49561,2642.598,4771.06738,2846.840,
3692.58716,2641.598,4771.15869,2847.840,
3692.67847,2641.598,4771.25049,2847.840,
3692.77002,2641.598,4771.34180,2847.840,
3692.86157,2641.598,4771.43359,2848.840,
3692.95313,2641.598,4771.52490,2848.840,
3693.04468,2641.598,4771.61670,2848.840,
3693.13623,2641.598,4771.70801,2848.840,
3693.22778,2642.598,4771.79932,2847.840,
3693.31934,2642.598,4771.89111,2847.840,
3693.41064,2642.598,4771.98242,2847.840,
3693.50220,2642.598,4772.07422,2847.840,
3693.59375,2643.598,4772.16553,2847.840,
3693.68530,2643.598,4772.25732,2846.840,
3693.77686,2643.598,4772.34863,2846.840,
3693.86841,2643.598,4772.44043,2845.840,
3693.95996,2644.598,4772.53174,2845.840,
3694.05151,2644.598,4772.62305,2845.840,
3694.14282,2644.598,4772.71484,2845.840,
3694.23438,2644.598,4772.80615,2845.840,
3694.32593,2644.598,4772.89795,2844.840,
3694.41748,2645.598,4772.98926,2845.840,
3694.50903,2645.598,4773.08105,2844.840,
3694.60059,2646.598,4773.17236,2845.840,
3694.69214,2645.598,4773.26367,2844.840,
3694.78345,2646.598,4773.35547,2844.840,
3694.87500,2646.598,4773.44678,2844.840,
3694.96655,2646.598,4773.53857,2843.840,
3695.05811,2646.598,4773.62988,2843.840,
3695.14966,2646.598,4773.72168,2842.840,
3695.24121,2646.598,4773.81299,2841.840,
3695.33276,2647.598,4773.90430,2841.840,
3695.42432,2648.598,4773.99609,2841.840,
3695.51563,2647.598,4774.08740,2841.840,
3695.60718,2647.598,4774.17920,2841.840,
3695.69873,2647.598,4774.27051,2841.840,
3695.79028,2648.598,4774.36230,2841.840,
3695.88184,2648.598,4774.45361,2841.840,
3695.97339,2648.598,4774.54541,2841.840,
3696.06494,2648.598,4774.63672,2842.840,
3696.15625,2648.598,4774.72803,2841.840,
3696.24780,2648.598,4774.81982,2842.840,
3696.33936,2649.598,4774.91113,2842.840,
3696.43091,2649.598,4775.00293,2842.840,
3696.52246,2649.598,4775.09424,2842.840,
3696.61401,2649.598,4775.18604,2842.840,
3696.70557,2649.598,4775.27734,2843.840,
3696.79712,2650.598,4775.36865,2843.840,
3696.88843,2650.598,4775.46045,2843.840,
3696.97998,2650.598,4775.55176,2842.840,
3697.07153,2650.598,4775.64355,2842.840,
3697.16309,2650.598,4775.73486,2842.840,
3697.25464,2651.598,4775.82666,2842.840,
3697.34619,2650.598,4775.91797,2842.840,
3697.43774,2650.598,4776.00928,2842.840,
3697.52930,2651.598,4776.10107,2842.840,
3697.62061,2651.598,4776.19238,2841.840,
3697.71216,2651.598,4776.28418,2841.840,
3697.80371,2652.598,4776.37549,2841.840,
3697.89526,2652.598,4776.46729,2841.840,
3697.98682,2652.598,4776.55859,2841.840,
3698.07837,2652.598,4776.65039,2841.840,
3698.16992,2652.598,4776.74170,2841.840,
3698.26123,2652.598,4776.83301,2841.840,
3698.35278,2653.598,4776.92480,2841.840,
3698.44434,2653.598,4777.01611,2840.840,
3698.53589,2653.598,4777.10791,2841.840,
3698.62744,2653.598,4777.19922,2840.840,
3698.71899,2653.598,4777.29102,2841.840,
3698.81055,2654.598,4777.38232,2841.840,
3698.90210,2654.598,4777.47363,2840.840,
3698.99341,2654.598,4777.56543,2841.840,
3699.08496,2654.598,4777.65674,2841.840,
3699.17651,2654.598,4777.74854,2840.840,
3699.26807,2654.598,4777.83984,2840.840,
3699.35962,2654.598,4777.93164,2840.840,
3699.45117,2655.598,4778.02295,2840.840,
3699.54272,2655.598,4778.11426,2840.840,
3699.63428,2656.598,4778.20605,2840.840,
3699.72559,2655.598,4778.29736,2840.840,
3699.81714,2656.598,4778.38916,2840.840,
3699.90869,2656.598,4778.48047,2840.840,
3700.00024,2656.598,4778.57227,2840.840,
3700.09180,2656.598,4778.66357,2839.840,
3700.18335,2656.598,4778.75537,2840.840,
3700.27490,2656.598,4778.84668,2839.840,
3700.36621,2656.598,4778.93799,2839.840,
3700.45776,2657.598,4779.02979,2840.840,
3700.54932,2656.598,4779.12109,2839.840,
3700.64087,2656.598,4779.21289,2839.840,
3700.73242,2657.598,4779.30420,2839.840,
3700.82397,2658.598,4779.39600,2839.840,
3700.91553,2657.598,4779.48730,2839.840,
3701.00708,2658.598,4779.57861,2838.840,
3701.09839,2658.598,4779.67041,2838.840,
3701.18994,2658.598,4779.76172,2839.840,
3701.28149,2659.598,4779.85352,2838.840,
3701.37305,2659.598,4779.94482,2838.840,
3701.46460,2659.598,4780.03662,2838.840,
3701.55615,2659.598,4780.12793,2838.840,
3701.64771,2659.598,4780.21924,2838.840,
3701.73901,2659.598,4780.31104,2838.840,
3701.83057,2659.598,4780.40234,2838.840,
3701.92212,2660.598,4780.49414,2838.840,
3702.01367,2659.598,4780.58545,2838.840,
3702.10522,2660.598,4780.67725,2838.840,
3702.19678,2660.598,4780.76855,2838.840,
3702.28833,2660.598,4780.86035,2838.840,
3702.37988,2660.598,4780.95166,2837.840,
3702.47119,2660.598,4781.04297,2837.840,
3702.56274,2661.598,4781.13477,2837.840,
3702.65430,2661.598,4781.22607,2837.840,
3702.74585,2661.598,4781.31787,2837.840,
3702.83740,2661.598,4781.40918,2837.840,
3702.92896,2661.598,4781.50098,2837.840,
3703.02051,2662.598,4781.59229,2837.840,
3703.11206,2661.598,4781.68359,2836.840,
3703.20337,2662.598,4781.77539,2837.840,
3703.29492,2661.598,4781.86670,2836.840,
3703.38647,2662.598,4781.95850,2836.840,
3703.47803,2662.598,4782.04980,2837.840,
3703.56958,2662.598,4782.14160,2836.840,
3703.66113,2662.598,4782.23291,2835.840,
3703.75269,2663.598,4782.32422,2835.840,
3703.84399,2662.598,4782.41602,2836.840,
3703.93555,2662.598,4782.50732,2836.840,
3704.02710,2663.598,4782.59912,2836.840,
3704.11865,2663.598,4782.69043,2836.840,
3704.21021,2664.598,4782.78223,2835.840,
3704.30176,2663.598,4782.87354,2835.840,
3704.39331,2664.598,4782.96484,2835.840,
3704.48486,2664.598,4783.05664,2835.840,
3704.57617,2664.598,4783.14795,2835.840,
3704.66772,2663.598,4783.23975,2835.840,
3704.75928,2665.598,4783.33105,2835.840,
3704.85083,2665.598,4783.42285,2835.840,
3704.94238,2665.598,4783.51416,2835.840,
3705.03394,2665.598,4783.60596,2835.840,
3705.12549,2665.598,4783.69727,2835.840,
3705.21704,2665.598,4783.78857,2834.840,
3705.30835,2665.598,4783.88037,2834.840,
3705.39990,2666.598,4783.97168,2834.840,
3705.49146,2666.598,4784.06348,2834.840,
3705.58301,2665.598,4784.15479,2834.840,
3705.67456,2666.598,4784.24658,2834.840,
3705.76611,2666.598,4784.33789,2834.840,
3705.85767,2666.598,4784.42920,2834.840,
3705.94897,2667.598,4784.52100,2834.840,
3706.04053,2667.598,4784.61230,2834.840,
3706.13208,2667.598,4784.70410,2833.840,
3706.22363,2666.598,4784.79541,2833.840,
3706.31519,2666.598,4784.88721,2834.840,
3706.40674,2667.598,4784.97852,2833.840,
3706.49829,2667.598,4785.06982,2833.840,
3706.58984,2667.598,4785.16162,2833.840,
3706.68115,2668.598,4785.25293,2833.840,
3706.77271,2668.598,4785.34473,2833.840,
3706.86426,2668.598,4785.43604,2833.840,
3706.95581,2668.598,4785.52783,2833.840,
3707.04736,2668.598,4785.61914,2833.840,
3707.13892,2670.598,4785.71094,2833.840,
3707.23047,2669.598,4785.80225,2832.840,
3707.32178,2669.598,4785.89355,2832.840,
3707.41333,2669.598,4785.98535,2832.840,
3707.50488,2669.598,4786.07666,2832.840,
3707.59644,2670.598,4786.16846,2833.840,
3707.68799,2669.598,4786.25977,2832.840,
3707.77954,2669.598,4786.35156,2833.840,
3707.87109,2670.598,4786.44287,2832.840,
3707.96265,2671.598,4786.53418,2832.840,
3708.05396,2671.598,4786.62598,2831.840,
3708.14551,2671.598,4786.71729,2831.840,
3708.23706,2671.598,4786.80908,2832.840,
3708.32861,2671.598,4786.90039,2832.840,
3708.42017,2671.598,4786.99219,2831.840,
3708.51172,2671.598,4787.08350,2831.840,
3708.60327,2672.598,4787.17480,2831.840,
3708.69482,2672.598,4787.26660,2831.840,
3708.78613,2672.598,4787.35791,2831.840,
3708.87769,2673.598,4787.44971,2832.840,
3708.96924,2672.598,4787.54102,2831.840,
3709.06079,2673.598,4787.63281,2831.840,
3709.15234,2673.598,4787.72412,2831.840,
3709.24390,2673.598,4787.81592,2831.840,
3709.33545,2673.598,4787.90723,2830.840,
3709.42676,2672.598,4787.99854,2830.840,
3709.51831,2673.598,4788.09033,2830.840,
3709.60986,2673.598,4788.18164,2830.840,
3709.70142,2673.598,4788.27344,2830.840,
3709.79297,2674.598,4788.36475,2830.840,
3709.88452,2674.598,4788.45654,2830.840,
3709.97607,2674.598,4788.54785,2829.840,
3710.06763,2675.598,4788.63916,2829.840,
3710.15894,2675.598,4788.73096,2829.840,
3710.25049,2675.598,4788.82227,2829.840,
3710.34204,2676.598,4788.91406,2829.840,
3710.43359,2676.598,4789.00537,2829.840,
3710.52515,2676.598,4789.09717,2829.840,
3710.61670,2677.598,4789.18848,2829.840,
3710.70825,2677.598,4789.27979,2829.840,
3710.79980,2677.598,4789.37158,2829.840,
3710.89111,2677.598,4789.46289,2829.840,
3710.98267,2677.598,4789.55469,2829.840,
3711.07422,2677.598,4789.64600,2829.840,
3711.16577,2677.598,4789.73779,2828.840,
3711.25732,2677.598,4789.82910,2828.840,
3711.34888,2677.598,4789.92090,2828.840,
3711.44043,2677.598,4790.01221,2828.840,
3711.53174,2678.598,4790.10352,2827.840,
3711.62329,2677.598,4790.19531,2827.840,
3711.71484,2677.598,4790.28662,2826.840,
3711.80640,2678.598,4790.37842,2826.840,
3711.89795,2677.598,4790.46973,2826.840,
3711.98950,2677.598,4790.56152,2826.840,
3712.08105,2678.598,4790.65283,2825.840,
3712.17261,2678.598,4790.74414,2826.840,
3712.26392,2677.598,4790.83594,2826.840,
3712.35547,2677.598,4790.92725,2825.840,
3712.44702,2676.598,4791.01904,2826.840,
3712.53857,2675.598,4791.11035,2826.840,
3712.63013,2675.598,4791.20215,2825.840,
3712.72168,2675.598,4791.29346,2826.840,
3712.81323,2675.598,4791.38477,2826.840,
3712.90454,2675.598,4791.47656,2826.840,
3712.99609,2676.598,4791.56787,2826.840,
3713.08765,2675.598,4791.65967,2826.840,
3713.17920,2676.598,4791.75098,2826.840,
3713.27075,2677.598,4791.84277,2826.840,
3713.36230,2678.598,4791.93408,2826.840,
3713.45386,2678.598,4792.02588,2826.840,
3713.54541,2679.598,4792.11719,2826.840,
3713.63672,2679.598,4792.20850,2827.840,
3713.72827,2679.598,4792.30029,2826.840,
3713.81982,2680.598,4792.39160,2826.840,
3713.91138,2680.598,4792.48340,2827.840,
3714.00293,2680.598,4792.57471,2827.840,
3714.09448,2681.598,4792.66650,2828.840,
3714.18604,2681.598,4792.75781,2828.840,
3714.27759,2681.598,4792.84912,2828.840,
3714.36890,2681.598,4792.94092,2827.840,
3714.46045,2682.598,4793.03223,2827.840,
3714.55200,2682.598,4793.12402,2827.840,
3714.64355,2682.598,4793.21533,2826.840,
3714.73511,2683.598,4793.30713,2826.840,
3714.82666,2683.598,4793.39844,2826.840,
3714.91821,2683.598,4793.48975,2825.840,
3715.00952,2683.598,4793.58154,2825.840,
3715.10107,2683.598,4793.67285,2825.840,
3715.19263,2684.598,4793.76465,2824.840,
3715.28418,2683.598,4793.85596,2824.840,
3715.37573,2683.598,4793.94775,2824.840,
3715.46729,2684.598,4794.03906,2823.840,
3715.55884,2683.598,4794.13086,2823.840,
3715.65039,2684.598,4794.22217,2823.840,
3715.74170,2684.598,4794.31348,2823.840,
3715.83325,2684.598,4794.40527,2823.840,
3715.92480,2685.598,4794.49658,2823.840,
3716.01636,2685.598,4794.58838,2823.840,
3716.10791,2685.598,4794.67969,2823.840,
3716.19946,2685.598,4794.77148,2823.840,
3716.29102,2685.598,4794.86279,2823.840,
3716.38257,2685.598,4794.95410,2823.840,
3716.47388,2685.598,4795.04590,2823.840,
3716.56543,2686.598,4795.13721,2823.840,
3716.65698,2685.598,4795.22900,2822.840,
3716.74854,2686.598,4795.32031,2822.840,
3716.84009,2686.598,4795.41211,2823.840,
3716.93164,2686.598,4795.50342,2822.840,
3717.02319,2686.598,4795.59473,2822.840,
3717.11450,2687.598,4795.68652,2823.840,
3717.20605,2687.598,4795.77783,2822.840,
3717.29761,2687.598,4795.86963,2822.840,
3717.38916,2688.598,4795.96094,2822.840,
3717.48071,2688.598,4796.05273,2822.840,
3717.57227,2687.598,4796.14404,2822.840,
3717.66382,2687.598,4796.23535,2821.840,
3717.75537,2688.598,4796.32715,2822.840,
3717.84668,2688.598,4796.41846,2821.840,
3717.93823,2688.598,4796.51025,2821.840,
3718.02979,2689.598,4796.60156,2821.840,
3718.12134,2688.598,4796.69336,2821.840,
3718.21289,2689.598,4796.78467,2821.840,
3718.30444,2689.598,4796.87646,2821.840,
3718.39600,2689.598,4796.96777,2820.840,
3718.48755,2689.598,4797.05908,2821.840,
3718.57886,2689.598,4797.15088,2821.840,
3718.67041,2689.598,4797.24219,2821.840,
3718.76196,2689.598,4797.33398,2820.840,
3718.85352,2691.598,4797.42529,2820.840,
3718.94507,2690.598,4797.51709,2820.840,
3719.03662,2690.598,4797.60840,2820.840,
3719.12817,2690.598,4797.69971,2820.840,
3719.21948,2691.598,4797.79150,2820.840,
3719.31104,2691.598,4797.88281,2820.840,
3719.40259,2691.598,4797.97461,2820.840,
3719.49414,2691.598,4798.06592,2820.840,
3719.58569,2691.598,4798.15771,2820.840,
3719.67725,2691.598,4798.24902,2819.840,
3719.76880,2691.598,4798.34033,2819.840,
3719.86035,2691.598,4798.43213,2819.840,
3719.95166,2691.598,4798.52344,2819.840,
3720.04321,2692.598,4798.61523,2819.840,
3720.13477,2692.598,4798.70654,2819.840,
3720.22632,2692.598,4798.79834,2819.840,
3720.31787,2693.598,4798.88965,2819.840,
3720.40942,2692.598,4798.98145,2819.840,
3720.50098,2693.598,4799.07275,2818.840,
3720.59229,2692.598,4799.16406,2818.840,
3720.68384,2693.598,4799.25586,2818.840,
3720.77539,2693.598,4799.34717,2818.840,
3720.86694,2693.598,4799.43896,2818.840,
3720.95850,2693.598,4799.53027,2818.840,
3721.05005,2694.598,4799.62207,2817.840,
3721.14160,2693.598,4799.71338,2818.840,
3721.23315,2694.598,4799.80469,2818.840,
3721.32446,2694.598,4799.89648,2817.840,
3721.41602,2694.598,4799.98779,2817.840,
3721.50757,2694.598,4800.07959,2817.840,
3721.59912,2694.598,4800.17090,2817.840,
3721.69067,2694.598,4800.26270,2817.840,
3721.78223,2695.598,4800.35400,2817.840,
3721.87378,2695.598,4800.44531,2817.840,
3721.96533,2695.598,4800.53711,2817.840,
3722.05664,2695.598,4800.62842,2816.840,
3722.14819,2696.598,4800.72021,2816.840,
3722.23975,2695.598,4800.81152,2817.840,
3722.33130,2696.598,4800.90332,2816.840,
3722.42285,2696.598,4800.99463,2817.840,
3722.51440,2696.598,4801.08643,2816.840,
3722.60596,2696.598,4801.17773,2816.840,
3722.69727,2696.598,4801.26904,2816.840,
3722.78882,2696.598,4801.36084,2816.840,
3722.88037,2696.598,4801.45215,2816.840,
3722.97192,2697.598,4801.54395,2816.840,
3723.06348,2697.598,4801.63525,2816.840,
3723.15503,2697.598,4801.72705,2815.840,
3723.24658,2698.598,4801.81836,2815.840,
3723.33813,2698.598,4801.90967,2815.840,
3723.42944,2698.598,4802.00146,2815.840,
3723.52100,2698.598,4802.09277,2815.840,
3723.61255,2698.598,4802.18457,2815.840,
3723.70410,2698.598,4802.27588,2815.840,
3723.79565,2698.598,4802.36768,2815.840,
3723.88721,2699.598,4802.45898,2815.840,
3723.97876,2699.598,4802.55029,2814.840,
3724.07031,2699.598,4802.64209,2815.840,
3724.16162,2699.598,4802.73340,2814.840,
3724.25317,2699.598,4802.82520,2814.840,
3724.34473,2699.598,4802.91650,2814.840,
3724.43628,2699.598,4803.00830,2814.840,
3724.52783,2700.598,4803.09961,2814.840,
3724.61938,2699.598,4803.19141,2814.840,
3724.71094,2700.598,4803.28271,2813.840,
3724.80225,2700.598,4803.37402,2813.840,
3724.89380,2700.598,4803.46582,2813.840,
3724.98535,2701.598,4803.55713,2813.840,
3725.07690,2700.598,4803.64893,2813.840,
3725.16846,2701.598,4803.74023,2813.840,
3725.26001,2701.598,4803.83203,2813.840,
3725.35156,2701.598,4803.92334,2813.840,
3725.44312,2702.598,4804.01465,2812.840,
3725.53442,2701.598,4804.10645,2813.840,
3725.62598,2701.598,4804.19775,2813.840,
3725.71753,2701.598,4804.28955,2812.840,
3725.80908,2702.598,4804.38086,2812.840,
3725.90063,2702.598,4804.47266,2813.840,
3725.99219,2701.598,4804.56396,2812.840,
3726.08374,2702.598,4804.65527,2812.840,
3726.17505,2703.598,4804.74707,2812.840,
3726.26660,2702.598,4804.83838,2812.840,
3726.35815,2703.598,4804.93018,2811.840,
3726.44971,2703.598,4805.02148,2812.840,
3726.54126,2703.598,4805.11328,2811.840,
3726.63281,2703.598,4805.20459,2811.840,
3726.72437,2703.598,4805.29639,2811.840,
3726.81592,2703.598,4805.38770,2812.840,
3726.90723,2703.598,4805.47900,2811.840,
3726.99878,2703.598,4805.57080,2811.840,
3727.09033,2703.598,4805.66211,2811.840,
3727.18188,2704.598,4805.75391,2811.840,
3727.27344,2704.598,4805.84521,2811.840,
3727.36499,2704.598,4805.93701,2811.840,
3727.45654,2704.598,4806.02832,2810.840,
3727.54810,2704.598,4806.11963,2811.840,
3727.63940,2706.598,4806.21143,2810.840,
3727.73096,2705.598,4806.30273,2810.840,
3727.82251,2705.598,4806.39453,2810.840,
3727.91406,2705.598,4806.48584,2810.840,
3728.00562,2705.598,4806.57764,2810.840,
3728.09717,2705.598,4806.66895,2810.840,
3728.18872,2706.598,4806.76025,2810.840,
3728.28003,2705.598,4806.85205,2809.840,
3728.37158,2706.598,4806.94336,2809.840,
3728.46313,2706.598,4807.03516,2809.840,
3728.55469,2706.598,4807.12646,2809.840,
3728.64624,2706.598,4807.21826,2808.840,
3728.73779,2706.598,4807.30957,2809.840,
3728.82935,2706.598,4807.40088,2808.840,
3728.92090,2707.598,4807.49268,2809.840,
3729.01221,2706.598,4807.58398,2808.840,
3729.10376,2707.598,4807.67578,2808.840,
3729.19531,2705.598,4807.76709,2808.840,
3729.28687,2706.598,4807.85889,2808.840,
3729.37842,2705.598,4807.95020,2808.840,
3729.46997,2705.598,4808.04199,2808.840,
3729.56152,2705.598,4808.13330,2808.840,
3729.65308,2705.598,4808.22461,2808.840,
3729.74438,2706.598,4808.31641,2808.840,
3729.83594,2706.598,4808.40771,2808.840,
3729.92749,2706.598,4808.49951,2808.840,
3730.01904,2706.598,4808.59082,2807.840,
3730.11060,2706.598,4808.68262,2807.840,
3730.20215,2707.598,4808.77393,2807.840,
3730.29370,2707.598,4808.86523,2807.840,
3730.38501,2707.598,4808.95703,2806.840,
3730.47656,2708.598,4809.04834,2807.840,
3730.56812,2709.598,4809.14014,2806.840,
3730.65967,2708.598,4809.23145,2805.840,
3730.75122,2709.598,4809.32324,2805.840,
3730.84277,2709.598,4809.41455,2805.840,
3730.93433,2709.598,4809.50586,2804.840,
3731.02588,2710.598,4809.59766,2804.840,
3731.11719,2710.598,4809.68896,2804.840,
3731.20874,2711.598,4809.78076,2804.840,
3731.30029,2711.598,4809.87207,2804.840,
3731.39185,2711.598,4809.96387,2804.840,
3731.48340,2712.598,4810.05518,2804.840,
3731.57495,2712.598,4810.14697,2804.840,
3731.66650,2714.598,4810.23828,2805.840,
3731.75781,2714.598,4810.32959,2804.840,
3731.84937,2714.598,4810.42139,2804.840,
3731.94092,2715.598,4810.51270,2804.840,
3732.03247,2715.598,4810.60449,2805.840,
3732.12402,2715.598,4810.69580,2804.840,
3732.21558,2715.598,4810.78760,2804.840,
3732.30713,2714.598,4810.87891,2804.840,
3732.39868,2714.598,4810.97021,2804.840,
3732.48999,2714.598,4811.06201,2804.840,
3732.58154,2714.598,4811.15332,2804.840,
3732.67310,2714.598,4811.24512,2805.840,
3732.76465,2714.598,4811.33643,2804.840,
3732.85620,2714.598,4811.42822,2805.840,
3732.94775,2714.598,4811.51953,2805.840,
3733.03931,2714.598,4811.61084,2805.840,
3733.13086,2714.598,4811.70264,2806.840,
3733.22217,2715.598,4811.79395,2806.840,
3733.31372,2714.598,4811.88574,2806.840,
3733.40527,2715.598,4811.97705,2805.840,
3733.49683,2715.598,4812.06885,2805.840,
3733.58838,2714.598,4812.16016,2805.840,
3733.67993,2715.598,4812.25195,2804.840,
3733.77148,2715.598,4812.34326,2804.840,
3733.86279,2715.598,4812.43457,2803.840,
3733.95435,2715.598,4812.52637,2803.840,
3734.04590,2715.598,4812.61768,2803.840,
3734.13745,2715.598,4812.70947,2803.840,
3734.22900,2716.598,4812.80078,2802.840,
3734.32056,2716.598,4812.89258,2802.840,
3734.41211,2716.598,4812.98389,2802.840,
3734.50366,2716.598,4813.07520,2802.840,
3734.59497,2716.598,4813.16699,2802.840,
3734.68652,2716.598,4813.25830,2801.840,
3734.77808,2716.598,4813.35010,2801.840,
3734.86963,2716.598,4813.44141,2801.840,
3734.96118,2717.598,4813.53320,2801.840,
3735.05273,2717.598,4813.62451,2801.840,
3735.14429,2717.598,4813.71582,2801.840,
3735.23584,2717.598,4813.80762,2801.840,
3735.32715,2718.598,4813.89893,2801.840,
3735.41870,2717.598,4813.99072,2800.840,
3735.51025,2717.598,4814.08203,2800.840,
3735.60181,2717.598,4814.17383,2800.840,
3735.69336,2718.598,4814.26514,2800.840,
3735.78491,2718.598,4814.35693,2800.840,
3735.87646,2718.598,4814.44824,2800.840,
3735.96777,2718.598,4814.53955,2800.840,
3736.05933,2718.598,4814.63135,2800.840,
3736.15088,2719.598,4814.72266,2800.840,
3736.24243,2719.598,4814.81445,2800.840,
3736.33398,2719.598,4814.90576,2800.840,
3736.42554,2720.598,4814.99756,2799.840,
3736.51709,2719.598,4815.08887,2799.840,
3736.60864,2719.598,4815.18018,2799.840,
3736.69995,2719.598,4815.27197,2799.840,
3736.79150,2720.598,4815.36328,2799.840,
3736.88306,2720.598,4815.45508,2798.840,
3736.97461,2720.598,4815.54639,2798.840,
3737.06616,2720.598,4815.63818,2800.840,
3737.15771,2720.598,4815.72949,2798.840,
3737.24927,2720.598,4815.82080,2799.840,
3737.34082,2720.598,4815.91260,2798.840,
3737.43213,2720.598,4816.00391,2798.840,
3737.52368,2721.598,4816.09570,2798.840,
3737.61523,2721.598,4816.18701,2798.840,
3737.70679,2720.598,4816.27881,2798.840,
3737.79834,2721.598,4816.37012,2798.840,
3737.88989,2722.598,4816.46191,2797.840,
3737.98145,2722.598,4816.55322,2798.840,
3738.07275,2721.598,4816.64453,2797.840,
3738.16431,2721.598,4816.73633,2797.840,
3738.25586,2722.598,4816.82764,2797.840,
3738.34741,2721.598,4816.91943,2797.840,
3738.43896,2722.598,4817.01074,2797.840,
3738.53052,2722.598,4817.10254,2797.840,
3738.62207,2722.598,4817.19385,2797.840,
3738.71362,2722.598,4817.28516,2796.840,
3738.80493,2722.598,4817.37695,2797.840,
3738.89648,2723.598,4817.46826,2796.840,
3738.98804,2723.598,4817.56006,2796.840,
3739.07959,2723.598,4817.65137,2796.840,
3739.17114,2723.598,4817.74316,2796.840,
3739.26270,2723.598,4817.83447,2795.840,
3739.35425,2724.598,4817.92578,2795.840,
3739.44556,2723.598,4818.01758,2795.840,
3739.53711,2724.598,4818.10889,2795.840,
3739.62866,2724.598,4818.20068,2795.840,
3739.72021,2724.598,4818.29199,2795.840,
3739.81177,2724.598,4818.38379,2795.840,
3739.90332,2724.598,4818.47510,2795.840,
3739.99487,2724.598,4818.56689,2796.840,
3740.08643,2725.598,4818.65820,2795.840,
3740.17773,2725.598,4818.74951,2795.840,
3740.26929,2725.598,4818.84131,2795.840,
3740.36084,2725.598,4818.93262,2794.840,
3740.45239,2725.598,4819.02441,2794.840,
3740.54395,2726.598,4819.11572,2794.840,
3740.63550,2726.598,4819.20752,2794.840,
3740.72705,2725.598,4819.29883,2794.840,
3740.81860,2727.598,4819.39014,2794.840,
3740.90991,2726.598,4819.48193,2793.840,
3741.00146,2726.598,4819.57324,2793.840,
3741.09302,2726.598,4819.66504,2793.840,
3741.18457,2726.598,4819.75635,2793.840,
3741.27612,2726.598,4819.84814,2793.840,
3741.36768,2727.598,4819.93945,2793.840,
3741.45923,2727.598,4820.03076,2793.840,
3741.55054,2727.598,4820.12256,2792.840,
3741.64209,2727.598,4820.21387,2793.840,
3741.73364,2727.598,4820.30566,2792.840,
3741.82520,2728.598,4820.39697,2792.840,
3741.91675,2727.598,4820.48877,2792.840,
3742.00830,2728.598,4820.58008,2793.840,
3742.09985,2728.598,4820.67139,2792.840,
3742.19141,2728.598,4820.76318,2792.840,
3742.28271,2729.598,4820.85449,2792.840,
3742.37427,2729.598,4820.94629,2792.840,
3742.46582,2728.598,4821.03760,2791.840,
3742.55737,2728.598,4821.12939,2791.840,
3742.64893,2728.598,4821.22070,2791.840,
3742.74048,2729.598,4821.31250,2791.840,
3742.83203,2729.598,4821.40381,2791.840,
3742.92358,2729.598,4821.49512,2791.840,
3743.01489,2729.598,4821.58691,2791.840,
3743.10645,2730.598,4821.67822,2791.840,
3743.19800,2729.598,4821.77002,2791.840,
3743.28955,2730.598,4821.86133,2790.840,
3743.38110,2730.598,4821.95313,2790.840,
3743.47266,2730.598,4822.04443,2790.840,
3743.56421,2730.598,4822.13574,2790.840,
3743.65552,2730.598,4822.22754,2790.840,
3743.74707,2731.598,4822.31885,2790.840,
3743.83862,2731.598,4822.41064,2790.840,
3743.93018,2731.598,4822.50195,2789.840,
3744.02173,2731.598,4822.59375,2789.840,
3744.11328,2731.598,4822.68506,2789.840,
3744.20483,2731.598,4822.77637,2789.840,
3744.29639,2731.598,4822.86816,2789.840,
3744.38770,2731.598,4822.95947,2789.840,
3744.47925,2732.598,4823.05127,2789.840,
3744.57080,2732.598,4823.14258,2789.840,
3744.66235,2732.598,4823.23438,2788.840,
3744.75391,2732.598,4823.32568,2789.840,
3744.84546,2732.598,4823.41748,2789.840,
3744.93701,2732.598,4823.50879,2788.840,
3745.02832,2733.598,4823.60010,2788.840,
3745.11987,2733.598,4823.69189,2788.840,
3745.21143,2733.598,4823.78320,2788.840,
3745.30298,2733.598,4823.87500,2788.840,
3745.39453,2733.598,4823.96631,2788.840,
3745.48608,2733.598,4824.05811,2787.840,
3745.57764,2733.598,4824.14941,2787.840,
3745.66919,2734.598,4824.24072,2787.840,
3745.76050,2734.598,4824.33252,2788.840,
3745.85205,2733.598,4824.42383,2787.840,
3745.94360,2734.598,4824.51563,2787.840,
3746.03516,2734.598,4824.60693,2787.840,
3746.12671,2734.598,4824.69873,2787.840,
3746.21826,2734.598,4824.79004,2787.840,
3746.30981,2735.598,4824.88135,2786.840,
3746.40137,2734.598,4824.97314,2786.840,
3746.49268,2735.598,4825.06445,2786.840,
3746.58423,2735.598,4825.15625,2786.840,
3746.67578,2735.598,4825.24756,2786.840,
3746.76733,2735.598,4825.33936,2786.840,
3746.85889,2735.598,4825.43066,2786.840,
3746.95044,2735.598,4825.52246,2786.840,
3747.04199,2736.598,4825.61377,2785.840,
3747.13330,2736.598,4825.70508,2785.840,
3747.22485,2736.598,4825.79688,2785.840,
3747.31641,2736.598,4825.88818,2786.840,
3747.40796,2736.598,4825.97998,2785.840,
3747.49951,2736.598,4826.07129,2785.840,
3747.59106,2737.598,4826.16309,2784.840,
3747.68262,2737.598,4826.25439,2784.840,
3747.77417,2737.598,4826.34570,2784.840,
3747.86548,2737.598,4826.43750,2784.840,
3747.95703,2737.598,4826.52881,2784.840,
3748.04858,2737.598,4826.62061,2784.840,
3748.14014,2738.598,4826.71191,2784.840,
3748.23169,2739.598,4826.80371,2784.840,
3748.32324,2739.598,4826.89502,2783.840,
3748.41479,2739.598,4826.98633,2783.840,
3748.50635,2740.598,4827.07813,2783.840,
3748.59766,2740.598,4827.16943,2783.840,
3748.68921,2741.598,4827.26123,2782.840,
3748.78076,2741.598,4827.35254,2783.840,
3748.87231,2741.598,4827.44434,2783.840,
3748.96387,2741.598,4827.53564,2783.840,
3749.05542,2741.598,4827.62744,2783.840,
3749.14697,2741.598,4827.71875,2783.840,
3749.23828,2741.598,4827.81006,2782.840,
3749.32983,2741.598,4827.90186,2782.840,
3749.42139,2741.598,4827.99316,2781.840,
3749.51294,2741.598,4828.08496,2781.840,
3749.60449,2741.598,4828.17627,2781.840,
3749.69604,2740.598,4828.26807,2781.840,
3749.78760,2741.598,4828.35938,2780.840,
3749.87915,2741.598,4828.45068,2780.840,
3749.97046,2741.598,4828.54248,2780.840,
3750.06201,2741.598,4828.63379,2780.840,
3750.15356,2741.598,4828.72559,2780.840,
3750.24512,2740.598,4828.81689,2780.840,
3750.33667,2741.598,4828.90869,2780.840,
3750.42822,2741.598,4829.00000,2780.840,
3750.51978,2740.598,4829.09131,2780.840,
3750.61108,2740.598,4829.18311,2780.840,
3750.70264,2739.598,4829.27441,2780.840,
3750.79419,2739.598,4829.36621,2780.840,
3750.88574,2739.598,4829.45752,2780.840,
3750.97729,2739.598,4829.54932,2780.840,
3751.06885,2740.598,4829.64063,2780.840,
3751.16040,2740.598,4829.73242,2779.840,
3751.25195,2740.598,4829.82373,2779.840,
3751.34326,2741.598,4829.91504,2779.840,
3751.43481,2741.598,4830.00684,2779.840,
3751.52637,2742.598,4830.09814,2778.840,
3751.61792,2742.598,4830.18994,2778.840,
3751.70947,2742.598,4830.28125,2778.840,
3751.80103,2742.598,4830.37305,2778.840,
3751.89258,2742.598,4830.46436,2778.840,
3751.98413,2743.598,4830.55566,2778.840,
3752.07544,2743.598,4830.64746,2778.840,
3752.16699,2743.598,4830.73877,2779.840,
3752.25854,2743.598,4830.83057,2779.840,
3752.35010,2743.598,4830.92188,2779.840,
3752.44165,2743.598,4831.01367,2779.840,
3752.53320,2744.598,4831.10498,2779.840,
3752.62476,2743.598,4831.19629,2779.840,
3752.71606,2744.598,4831.28809,2779.840,
3752.80762,2744.598,4831.37939,2778.840,
3752.89917,2744.598,4831.47119,2778.840,
3752.99072,2744.598,4831.56250,2777.840,
3753.08228,2744.598,4831.65430,2777.840,
3753.17383,2745.598,4831.74561,2778.840,
3753.26538,2745.598,4831.83740,2777.840,
3753.35693,2744.598,4831.92871,2776.840,
3753.44824,2745.598,4832.02002,2776.840,
3753.53979,2745.598,4832.11182,2776.840,
3753.63135,2746.598,4832.20313,2776.840,
3753.72290,2745.598,4832.29492,2775.840,
3753.81445,2745.598,4832.38623,2775.840,
3753.90601,2746.598,4832.47803,2776.840,
3753.99756,2746.598,4832.56934,2775.840,
3754.08911,2746.598,4832.66064,2775.840,
3754.18042,2746.598,4832.75244,2775.840,
3754.27197,2746.598,4832.84375,2775.840,
3754.36353,2747.598,4832.93555,2775.840,
3754.45508,2747.598,4833.02686,2774.840,
3754.54663,2747.598,4833.11865,2774.840,
3754.63818,2747.598,4833.20996,2775.840,
3754.72974,2747.598,4833.30127,2774.840,
3754.82104,2747.598,4833.39307,2774.840,
3754.91260,2747.598,4833.48438,2774.840,
3755.00415,2747.598,4833.57617,2774.840,
3755.09570,2748.598,4833.66748,2774.840,
3755.18726,2747.598,4833.75928,2774.840,
3755.27881,2747.598,4833.85059,2773.840,
3755.37036,2747.598,4833.94189,2773.840,
3755.46191,2749.598,4834.03369,2773.840,
3755.55322,2748.598,4834.12500,2773.840,
3755.64478,2748.598,4834.21680,2772.840,
3755.73633,2748.598,4834.30811,2773.840,
3755.82788,2749.598,4834.39990,2772.840,
3755.91943,2749.598,4834.49121,2772.840,
3756.01099,2749.598,4834.58301,2772.840,
3756.10254,2749.598,4834.67432,2772.840,
3756.19409,2749.598,4834.76563,2772.840,
3756.28540,2749.598,4834.85742,2772.840,
3756.37695,2749.598,4834.94873,2771.840,
3756.46851,2749.598,4835.04053,2771.840,
3756.56006,2749.598,4835.13184,2771.840,
3756.65161,2750.598,4835.22363,2771.840,
3756.74316,2750.598,4835.31494,2771.840,
3756.83472,2750.598,4835.40625,2771.840,
3756.92603,2751.598,4835.49805,2771.840,
3757.01758,2751.598,4835.58936,2771.840,
3757.10913,2750.598,4835.68115,2770.840,
3757.20068,2751.598,4835.77246,2770.840,
3757.29224,2751.598,4835.86426,2770.840,
3757.38379,2751.598,4835.95557,2770.840,
3757.47534,2751.598,4836.04688,2770.840,
3757.56689,2751.598,4836.13867,2771.840,
3757.65820,2751.598,4836.22998,2769.840,
3757.74976,2751.598,4836.32178,2769.840,
3757.84131,2751.598,4836.41309,2769.840,
3757.93286,2751.598,4836.50488,2769.840,
3758.02441,2751.598,4836.59619,2769.840,
3758.11597,2752.598,4836.68799,2769.840,
3758.20752,2752.598,4836.77930,2768.840,
3758.29883,2751.598,4836.87061,2768.840,
3758.39038,2753.598,4836.96240,2768.840,
3758.48193,2752.598,4837.05371,2768.840,
3758.57349,2753.598,4837.14551,2768.840,
3758.66504,2752.598,4837.23682,2768.840,
3758.75659,2753.598,4837.32861,2768.840,
3758.84814,2753.598,4837.41992,2768.840,
3758.93970,2753.598,4837.51123,2767.840,
3759.03101,2753.598,4837.60303,2768.840,
3759.12256,2753.598,4837.69434,2767.840,
3759.21411,2753.598,4837.78613,2767.840,
3759.30566,2753.598,4837.87744,2767.840,
3759.39722,2753.598,4837.96924,2767.840,
3759.48877,2754.598,4838.06055,2767.840,
3759.58032,2754.598,4838.15186,2767.840,
3759.67188,2754.598,4838.24365,2766.840,
3759.76318,2754.598,4838.33496,2767.840,
3759.85474,2755.598,4838.42676,2766.840,
3759.94629,2754.598,4838.51807,2766.840,
3760.03784,2754.598,4838.60986,2766.840,
3760.12939,2755.598,4838.70117,2766.840,
3760.22095,2755.598,4838.79297,2765.840,
3760.31250,2755.598,4838.88428,2765.840,
3760.40381,2755.598,4838.97559,2765.840,
3760.49536,2755.598,4839.06738,2765.840,
3760.58691,2755.598,4839.15869,2765.840,
3760.67847,2755.598,4839.25049,2765.840,
3760.77002,2755.598,4839.34180,2765.840,
3760.86157,2756.598,4839.43359,2764.840,
3760.95313,2755.598,4839.52490,2764.840,
3761.04468,2756.598,4839.61621,2764.840,
3761.13599,2756.598,4839.70801,2764.840,
3761.22754,2756.598,4839.79932,2764.840,
3761.31909,2757.598,4839.89111,2764.840,
3761.41064,2756.598,4839.98242,2764.840,
3761.50220,2757.598,4840.07422,2763.840,
3761.59375,2757.598,4840.16553,2764.840,
3761.68530,2757.598,4840.25684,2763.840,
3761.77686,2757.598,4840.34863,2763.840,
3761.86816,2757.598,4840.43994,2763.840,
3761.95972,2757.598,4840.53174,2763.840,
3762.05127,2758.598,4840.62305,2763.840,
3762.14282,2758.598,4840.71484,2762.840,
3762.23438,2758.598,4840.80615,2762.840,
3762.32593,2758.598,4840.89795,2762.840,
3762.41748,2758.598,4840.98926,2762.840,
3762.50879,2758.598,4841.08057,2762.840,
3762.60034,2758.598,4841.17236,2762.840,
3762.69189,2758.598,4841.26367,2761.840,
3762.78345,2759.598,4841.35547,2761.840,
3762.87500,2759.598,4841.44678,2761.840,
3762.96655,2759.598,4841.53857,2761.840,
3763.05811,2759.598,4841.62988,2761.840,
3763.14966,2759.598,4841.72119,2761.840,
3763.24097,2759.598,4841.81299,2760.840,
3763.33252,2759.598,4841.90430,2760.840,
3763.42407,2760.598,4841.99609,2761.840,
3763.51563,2760.598,4842.08740,2760.840,
3763.60718,2759.598,4842.17920,2760.840,
3763.69873,2760.598,4842.27051,2760.840,
3763.79028,2760.598,4842.36182,2760.840,
3763.88159,2760.598,4842.45361,2760.840,
3763.97314,2760.598,4842.54492,2759.840,
3764.06470,2760.598,4842.63672,2759.840,
3764.15625,2760.598,4842.72803,2759.840,
3764.24780,2761.598,4842.81982,2759.840,
3764.33936,2761.598,4842.91113,2759.840,
3764.43091,2761.598,4843.00293,2758.840,
3764.52246,2761.598,4843.09424,2758.840,
3764.61377,2762.598,4843.18555,2758.840,
3764.70532,2761.598,4843.27734,2758.840,
3764.79688,2762.598,4843.36865,2758.840,
3764.88843,2762.598,4843.46045,2758.840,
3764.97998,2761.598,4843.55176,2758.840,
3765.07153,2761.598,4843.64355,2758.840,
3765.16309,2762.598,4843.73486,2757.840,
3765.25464,2762.598,4843.82617,2757.840,
3765.34595,2762.598,4843.91797,2758.840,
3765.43750,2762.598,4844.00928,2757.840,
3765.52905,2762.598,4844.10107,2757.840,
3765.62061,2763.598,4844.19238,2757.840,
3765.71216,2763.598,4844.28418,2756.840,
3765.80371,2763.598,4844.37549,2756.840,
3765.89526,2763.598,4844.46680,2756.840,
3765.98657,2763.598,4844.55859,2756.840,
3766.07813,2763.598,4844.64990,2756.840,
3766.16968,2763.598,4844.74170,2756.840,
3766.26123,2763.598,4844.83301,2756.840,
3766.35278,2763.598,4844.92480,2756.840,
3766.44434,2763.598,4845.01611,2755.840,
3766.53589,2763.598,4845.10742,2755.840,
3766.62744,2763.598,4845.19922,2756.840,
3766.71875,2763.598,4845.29053,2755.840,
3766.81030,2763.598,4845.38232,2755.840,
3766.90186,2764.598,4845.47363,2754.840,
3766.99341,2764.598,4845.56543,2755.840,
3767.08496,2764.598,4845.65674,2754.840,
3767.17651,2766.598,4845.74854,2753.840,
3767.26807,2766.598,4845.83984,2753.840,
3767.35962,2766.598,4845.93115,2754.840,
3767.45093,2767.598,4846.02295,2753.840,
3767.54248,2768.598,4846.11426,2754.840,
3767.63403,2768.598,4846.20605,2753.840,
3767.72559,2767.598,4846.29736,2753.840,
3767.81714,2767.598,4846.38916,2754.840,
3767.90869,2768.598,4846.48047,2753.840,
3768.00024,2768.598,4846.57178,2753.840,
3768.09155,2768.598,4846.66357,2754.840,
3768.18311,2768.598,4846.75488,2753.840,
3768.27466,2768.598,4846.84668,2753.840,
3768.36621,2768.598,4846.93799,2753.840,
3768.45776,2767.598,4847.02979,2753.840,
3768.54932,2768.598,4847.12109,2752.840,
3768.64087,2768.598,4847.21240,2751.840,
3768.73242,2767.598,4847.30420,2751.840,
3768.82373,2768.598,4847.39551,2751.840,
3768.91528,2767.598,4847.48730,2751.840,
3769.00684,2767.598,4847.57861,2751.840,
3769.09839,2768.598,4847.67041,2751.840,
3769.18994,2768.598,4847.76172,2750.840,
3769.28149,2767.598,4847.85352,2751.840,
3769.37305,2768.598,4847.94482,2750.840,
3769.46436,2768.598,4848.03613,2750.840,
3769.55591,2768.598,4848.12793,2750.840,
3769.64746,2769.598,4848.21924,2750.840,
3769.73901,2769.598,4848.31104,2750.840,
3769.83057,2770.598,4848.40234,2749.840,
3769.92212,2770.598,4848.49414,2749.840,
3770.01367,2771.598,4848.58545,2749.840,
3770.10522,2771.598,4848.67676,2749.840,
3770.19653,2771.598,4848.76855,2748.840,
3770.28809,2771.598,4848.85986,2747.840,
3770.37964,2771.598,4848.95166,2747.840,
3770.47119,2772.598,4849.04297,2747.840,
3770.56274,2771.598,4849.13477,2747.840,
3770.65430,2771.598,4849.22607,2747.840,
3770.74585,2771.598,4849.31738,2747.840,
3770.83740,2771.598,4849.40918,2747.840,
3770.92871,2771.598,4849.50049,2748.840,
3771.02026,2771.598,4849.59229,2748.840,
3771.11182,2771.598,4849.68359,2748.840,
3771.20337,2771.598,4849.77539,2748.840,
3771.29492,2771.598,4849.86670,2748.840,
3771.38647,2771.598,4849.95850,2748.840,
3771.47803,2771.598,4850.04980,2748.840,
3771.56934,2771.598,4850.14111,2747.840,
3771.66089,2771.598,4850.23291,2747.840,
3771.75244,2771.598,4850.32422,2747.840,
3771.84399,2771.598,4850.41602,2747.840,
3771.93555,2771.598,4850.50732,2746.840,
3772.02710,2771.598,4850.59912,2746.840,
3772.11865,2771.598,4850.69043,2746.840,
3772.21021,2771.598,4850.78174,2747.840,
3772.30151,2772.598,4850.87354,2746.840,
3772.39307,2771.598,4850.96484,2746.840,
3772.48462,2772.598,4851.05664,2746.840,
3772.57617,2772.598,4851.14795,2745.840,
3772.66772,2772.598,4851.23975,2745.840,
3772.75928,2772.598,4851.33105,2745.840,
3772.85083,2772.598,4851.42236,2745.840,
3772.94238,2772.598,4851.51416,2745.840,
3773.03369,2773.598,4851.60547,2745.840,
3773.12524,2773.598,4851.69727,2744.840,
3773.21680,2774.598,4851.78857,2744.840,
3773.30835,2773.598,4851.88037,2744.840,
3773.39990,2773.598,4851.97168,2744.840,
3773.49146,2773.598,4852.06348,2744.840,
3773.58301,2773.598,4852.15479,2743.840,
3773.67432,2773.598,4852.24609,2744.840,
3773.76587,2773.598,4852.33789,2743.840,
3773.85742,2774.598,4852.42920,2743.840,
3773.94897,2774.598,4852.52100,2743.840,
3774.04053,2774.598,4852.61230,2743.840,
3774.13208,2775.598,4852.70410,2743.840,
3774.22363,2774.598,4852.79541,2742.840,
3774.31519,2774.598,4852.88672,2742.840,
3774.40649,2775.598,4852.97852,2742.840,
3774.49805,2775.598,4853.06982,2742.840,
3774.58960,2775.598,4853.16162,2741.840,
3774.68115,2775.598,4853.25293,2741.840,
3774.77271,2775.598,4853.34473,2741.840,
3774.86426,2775.598,4853.43604,2741.840,
3774.95581,2775.598,4853.52734,2741.840,
3775.04736,2775.598,4853.61914,2741.840,
3775.13867,2775.598,4853.71045,2741.840,
3775.23022,2776.598,4853.80225,2741.840,
3775.32178,2775.598,4853.89355,2740.840,
3775.41333,2776.598,4853.98535,2740.840,
3775.50488,2776.598,4854.07666,2740.840,
3775.59644,2776.598,4854.16846,2740.840,
3775.68799,2776.598,4854.25977,2740.840,
3775.77930,2776.598,4854.35107,2740.840,
3775.87085,2776.598,4854.44287,2740.840,
3775.96240,2777.598,4854.53418,2739.840,
3776.05396,2777.598,4854.62598,2739.840,
3776.14551,2777.598,4854.71729,2739.840,
3776.23706,2777.598,4854.80908,2739.840,
3776.32861,2777.598,4854.90039,2739.840,
3776.42017,2777.598,4854.99170,2738.840,
3776.51147,2777.598,4855.08350,2738.840,
3776.60303,2777.598,4855.17480,2739.840,
3776.69458,2778.598,4855.26660,2738.840,
3776.78613,2778.598,4855.35791,2739.840,
3776.87769,2778.598,4855.44971,2738.840,
3776.96924,2778.598,4855.54102,2738.840,
3777.06079,2778.598,4855.63232,2737.840,
3777.15210,2778.598,4855.72412,2737.840,
3777.24365,2779.598,4855.81543,2737.840,
3777.33521,2779.598,4855.90723,2737.840,
3777.42676,2779.598,4855.99854,2737.840,
3777.51831,2779.598,4856.09033,2736.840,
3777.60986,2779.598,4856.18164,2737.840,
3777.70142,2779.598,4856.27344,2737.840,
3777.79297,2779.598,4856.36475,2736.840,
3777.88428,2780.598,4856.45605,2736.840,
3777.97583,2779.598,4856.54785,2736.840,
3778.06738,2780.598,4856.63916,2736.840,
3778.15894,2779.598,4856.73096,2736.840,
3778.25049,2780.598,4856.82227,2736.840,
3778.34204,2780.598,4856.91406,2735.840,
3778.43359,2780.598,4857.00537,2735.840,
3778.52515,2780.598,4857.09668,2735.840,
3778.61646,2780.598,4857.18848,2735.840,
3778.70801,2780.598,4857.27979,2735.840,
3778.79956,2780.598,4857.37158,2734.840,
3778.89111,2781.598,4857.46289,2735.840,
3778.98267,2781.598,4857.55469,2734.840,
3779.07422,2781.598,4857.64600,2734.840,
3779.16577,2781.598,4857.73730,2734.840,
3779.25708,2781.598,4857.82910,2733.840,
3779.34863,2781.598,4857.92041,2734.840,
3779.44019,2782.598,4858.01221,2734.840,
3779.53174,2781.598,4858.10352,2733.840,
3779.62329,2782.598,4858.19531,2733.840,
3779.71484,2782.598,4858.28662,2733.840,
3779.80640,2782.598,4858.37793,2733.840,
3779.89795,2782.598,4858.46973,2733.840,
3779.98926,2782.598,4858.56104,2733.840,
3780.08081,2782.598,4858.65283,2733.840,
3780.17236,2782.598,4858.74414,2732.840,
3780.26392,2782.598,4858.83594,2732.840,
3780.35547,2783.598,4858.92725,2732.840,
3780.44702,2783.598,4859.01904,2732.840,
3780.53857,2783.598,4859.11035,2732.840,
3780.63013,2783.598,4859.20166,2732.840,
3780.72144,2783.598,4859.29346,2731.840,
3780.81299,2783.598,4859.38477,2731.840,
3780.90454,2783.598,4859.47656,2731.840,
3780.99609,2783.598,4859.56787,2732.840,
3781.08765,2783.598,4859.65967,2731.840,
3781.17920,2783.598,4859.75098,2731.840,
3781.27075,2784.598,4859.84229,2731.840,
3781.36206,2783.598,4859.93408,2730.840,
3781.45361,2783.598,4860.02539,2730.840,
3781.54517,2784.598,4860.11719,2730.840,
3781.63672,2784.598,4860.20850,2730.840,
3781.72827,2784.598,4860.30029,2729.840,
3781.81982,2785.598,4860.39160,2730.840,
3781.91138,2784.598,4860.48291,2729.840,
3782.00293,2785.598,4860.57471,2729.840,
3782.09424,2784.598,4860.66602,2729.840,
3782.18579,2784.598,4860.75781,2729.840,
3782.27734,2785.598,4860.84912,2729.840,
3782.36890,2785.598,4860.94092,2729.840,
3782.46045,2785.598,4861.03223,2729.840,
3782.55200,2785.598,4861.12402,2729.840,
3782.64355,2785.598,4861.21533,2728.840,
3782.73486,2785.598,4861.30664,2728.840,
3782.82642,2785.598,4861.39844,2728.840,
3782.91797,2785.598,4861.48975,2728.840,
3783.00952,2785.598,4861.58154,2728.840,
3783.10107,2786.598,4861.67285,2728.840,
3783.19263,2786.598,4861.76465,2727.840,
3783.28418,2786.598,4861.85596,2727.840,
3783.37573,2786.598,4861.94727,2726.840,
3783.46704,2786.598,4862.03906,2727.840,
3783.55859,2787.598,4862.13037,2726.840,
3783.65015,2786.598,4862.22217,2726.840,
3783.74170,2786.598,4862.31348,2726.840,
3783.83325,2787.598,4862.40527,2726.840,
3783.92480,2787.598,4862.49658,2727.840,
3784.01636,2787.598,4862.58789,2726.840,
3784.10791,2787.598,4862.67969,2725.840,
3784.19922,2786.598,4862.77100,2725.840,
3784.29077,2787.598,4862.86279,2725.840,
3784.38232,2787.598,4862.95410,2725.840,
3784.47388,2787.598,4863.04590,2725.840,
3784.56543,2788.598,4863.13721,2725.840,
3784.65698,2787.598,4863.22900,2724.840,
3784.74854,2788.598,4863.32031,2725.840,
3784.83984,2788.598,4863.41162,2725.840,
3784.93140,2788.598,4863.50342,2724.840,
3785.02295,2788.598,4863.59473,2724.840,
3785.11450,2789.598,4863.68652,2724.840,
3785.20605,2788.598,4863.77783,2724.840,
3785.29761,2789.598,4863.86963,2724.840,
3785.38916,2789.598,4863.96094,2724.840,
3785.48071,2789.598,4864.05225,2724.840,
3785.57202,2789.598,4864.14404,2723.840,
3785.66357,2789.598,4864.23535,2723.840,
3785.75513,2789.598,4864.32715,2723.840,
3785.84668,2789.598,4864.41846,2722.840,
3785.93823,2789.598,4864.51025,2722.840,
3786.02979,2789.598,4864.60156,2722.840,
3786.12134,2789.598,4864.69287,2722.840,
3786.21289,2790.598,4864.78467,2722.840,
3786.30420,2790.598,4864.87598,2722.840,
3786.39575,2790.598,4864.96777,2722.840,
3786.48730,2790.598,4865.05908,2721.840,
3786.57886,2790.598,4865.15088,2721.840,
3786.67041,2790.598,4865.24219,2721.840,
3786.76196,2790.598,4865.33398,2720.840,
3786.85352,2791.598,4865.42529,2720.840,
3786.94482,2791.598,4865.51660,2719.840,
3787.03638,2790.598,4865.60840,2719.840,
3787.12793,2791.598,4865.69971,2718.840,
3787.21948,2791.598,4865.79150,2719.840,
3787.31104,2791.598,4865.88281,2718.840,
3787.40259,2791.598,4865.97461,2718.840,
3787.49414,2791.598,4866.06592,2718.840,
3787.58569,2791.598,4866.15723,2718.840,
3787.67700,2792.598,4866.24902,2718.840,
3787.76855,2791.598,4866.34033,2718.840,
3787.86011,2792.598,4866.43213,2718.840,
3787.95166,2793.598,4866.52344,2718.840,
3788.04321,2793.598,4866.61523,2718.840,
3788.13477,2794.598,4866.70654,2718.840,
3788.22632,2794.598,4866.79785,2718.840,
3788.31763,2795.598,4866.88965,2718.840,
3788.40918,2796.598,4866.98096,2718.840,
3788.50073,2796.598,4867.07275,2718.840,
3788.59229,2796.598,4867.16406,2718.840,
3788.68384,2796.598,4867.25586,2717.840,
3788.77539,2796.598,4867.34717,2717.840,
3788.86694,2796.598,4867.43896,2716.840,
3788.95850,2797.598,4867.53027,2717.840,
3789.04980,2796.598,4867.62158,2716.840,
3789.14136,2796.598,4867.71338,2715.840,
3789.23291,2796.598,4867.80469,2716.840,
3789.32446,2795.598,4867.89648,2716.840,
3789.41602,2795.598,4867.98779,2716.840,
3789.50757,2795.598,4868.07959,2716.840,
3789.59912,2795.598,4868.17090,2716.840,
3789.69067,2795.598,4868.26221,2717.840,
3789.78198,2795.598,4868.35400,2717.840,
3789.87354,2795.598,4868.44531,2717.840,
3789.96509,2795.598,4868.53711,2716.840,
3790.05664,2795.598,4868.62842,2716.840,
3790.14819,2795.598,4868.72021,2716.840,
3790.23975,2795.598,4868.81152,2715.840,
3790.33130,2795.598,4868.90283,2715.840,
3790.42261,2795.598,4868.99463,2715.840,
3790.51416,2795.598,4869.08594,2715.840,
3790.60571,2795.598,4869.17773,2714.840,
3790.69727,2795.598,4869.26904,2714.840,
3790.78882,2796.598,4869.36084,2714.840,
3790.88037,2795.598,4869.45215,2714.840,
3790.97192,2796.598,4869.54346,2713.840,
3791.06348,2796.598,4869.63525,2713.840,
3791.15479,2796.598,4869.72656,2712.840,
3791.24634,2796.598,4869.81836,2713.840,
3791.33789,2796.598,4869.90967,2713.840,
3791.42944,2796.598,4870.00146,2712.840,
3791.52100,2797.598,4870.09277,2712.840,
3791.61255,2796.598,4870.18457,2712.840,
3791.70410,2797.598,4870.27588,2712.840,
3791.79565,2796.598,4870.36719,2711.840,
3791.88696,2797.598,4870.45898,2712.840,
3791.97852,2796.598,4870.55029,2712.840,
3792.07007,2797.598,4870.64209,2711.840,
3792.16162,2797.598,4870.73340,2711.840,
3792.25317,2797.598,4870.82520,2711.840,
3792.34473,2798.598,4870.91650,2710.840,
3792.43628,2798.598,4871.00781,2710.840,
3792.52759,2798.598,4871.09961,2711.840,
3792.61914,2797.598,4871.19092,2710.840,
3792.71069,2797.598,4871.28271,2710.840,
3792.80225,2798.598,4871.37402,2710.840,
3792.89380,2798.598,4871.46582,2709.840,
3792.98535,2798.598,4871.55713,2709.840,
3793.07690,2798.598,4871.64844,2710.840,
3793.16846,2799.598,4871.74023,2709.840,
3793.25977,2799.598,4871.83154,2709.840,
3793.35132,2799.598,4871.92334,2709.840,
3793.44287,2799.598,4872.01465,2709.840,
3793.53442,2799.598,4872.10645,2708.840,
3793.62598,2799.598,4872.19775,2708.840,
3793.71753,2799.598,4872.28955,2708.840,
3793.80908,2799.598,4872.38086,2708.840,
3793.90039,2799.598,4872.47217,2708.840,
3793.99194,2799.598,4872.56396,2708.840,
3794.08350,2799.598,4872.65527,2707.840,
3794.17505,2800.598,4872.74707,2708.840,
3794.26660,2800.598,4872.83838,2707.840,
3794.35815,2800.598,4872.93018,2706.840,
3794.44971,2800.598,4873.02148,2707.840,
3794.54126,2800.598,4873.11279,2707.840,
3794.63257,2800.598,4873.20459,2706.840,
3794.72412,2800.598,4873.29590,2706.840,
3794.81567,2800.598,4873.38770,2706.840,
3794.90723,2800.598,4873.47900,2706.840,
3794.99878,2801.598,4873.57080,2706.840,
3795.09033,2800.598,4873.66211,2705.840,
3795.18188,2801.598,4873.75342,2706.840,
3795.27344,2801.598,4873.84521,2706.840,
3795.36475,2801.598,4873.93652,2705.840,
3795.45630,2801.598,4874.02832,2705.840,
3795.54785,2801.598,4874.11963,2705.840,
3795.63940,2801.598,4874.21143,2705.840,
3795.73096,2801.598,4874.30273,2705.840,
3795.82251,2802.598,4874.39453,2704.840,
3795.91406,2801.598,4874.48584,2704.840,
3796.00537,2802.598,4874.57715,2704.840,
3796.09692,2802.598,4874.66895,2704.840,
3796.18848,2801.598,4874.76025,2703.840,
3796.28003,2802.598,4874.85205,2703.840,
3796.37158,2802.598,4874.94336,2703.840,
3796.46313,2802.598,4875.03516,2703.840,
3796.55469,2802.598,4875.12646,2703.840,
3796.64624,2802.598,4875.21777,2703.840,
3796.73755,2803.598,4875.30957,2703.840,
3796.82910,2803.598,4875.40088,2702.840,
3796.92065,2803.598,4875.49268,2702.840,
3797.01221,2802.598,4875.58398,2702.840,
3797.10376,2803.598,4875.67578,2702.840,
3797.19531,2803.598,4875.76709,2701.840,
3797.28687,2803.598,4875.85840,2701.840,
3797.37842,2803.598,4875.95020,2701.840,
3797.46973,2803.598,4876.04150,2701.840,
3797.56128,2803.598,4876.13330,2701.840,
3797.65283,2803.598,4876.22461,2701.840,
3797.74438,2804.598,4876.31641,2701.840,
3797.83594,2803.598,4876.40771,2701.840,
3797.92749,2805.598,4876.49951,2700.840,
3798.01904,2804.598,4876.59082,2700.840,
3798.11035,2804.598,4876.68213,2700.840,
3798.20190,2804.598,4876.77393,2700.840,
3798.29346,2804.598,4876.86523,2699.840,
3798.38501,2804.598,4876.95703,2700.840,
3798.47656,2804.598,4877.04834,2700.840,
3798.56812,2804.598,4877.14014,2699.840,
3798.65967,2805.598,4877.23145,2699.840,
3798.75122,2805.598,4877.32275,2699.840,
3798.84253,2805.598,4877.41455,2699.840,
3798.93408,2805.598,4877.50586,2699.840,
3799.02563,2805.598,4877.59766,2698.840,
3799.11719,2805.598,4877.68896,2699.840,
3799.20874,2805.598,4877.78076,2698.840,
3799.30029,2805.598,4877.87207,2698.840,
3799.39185,2806.598,4877.96338,2698.840,
3799.48340,2805.598,4878.05518,2697.840,
3799.57471,2806.598,4878.14648,2697.840,
3799.66626,2806.598,4878.23828,2697.840,
3799.75781,2806.598,4878.32959,2697.840,
3799.84937,2806.598,4878.42139,2697.840,
3799.94092,2806.598,4878.51270,2697.840,
3800.03247,2806.598,4878.60449,2697.840,
3800.12402,2806.598,4878.69580,2696.840,
3800.21533,2806.598,4878.78711,2697.840,
3800.30688,2806.598,4878.87891,2696.840,
3800.39844,2806.598,4878.97021,2696.840,
3800.48999,2807.598,4879.06201,2696.840,
3800.58154,2806.598,4879.15332,2695.840,
3800.67310,2807.598,4879.24512,2695.840,
3800.76465,2807.598,4879.33643,2695.840,
3800.85620,2807.598,4879.42773,2695.840,
3800.94751,2807.598,4879.51953,2694.840,
3801.03906,2808.598,4879.61084,2695.840,
3801.13062,2808.598,4879.70264,2694.840,
3801.22217,2807.598,4879.79395,2694.840,
3801.31372,2807.598,4879.88574,2694.840,
3801.40527,2808.598,4879.97705,2694.840,
3801.49683,2808.598,4880.06836,2694.840,
3801.58813,2808.598,4880.16016,2694.840,
3801.67969,2808.598,4880.25146,2694.840,
3801.77124,2808.598,4880.34326,2693.840,
3801.86279,2808.598,4880.43457,2693.840,
3801.95435,2808.598,4880.52637,2693.840,
3802.04590,2808.598,4880.61768,2693.840,
3802.13745,2808.598,4880.70947,2693.840,
3802.22900,2809.598,4880.80078,2692.840,
3802.32031,2809.598,4880.89209,2692.840,
3802.41187,2809.598,4880.98389,2691.840,
3802.50342,2809.598,4881.07520,2691.840,
3802.59497,2809.598,4881.16699,2691.840,
3802.68652,2809.598,4881.25830,2691.840,
3802.77808,2809.598,4881.35010,2691.840,
3802.86963,2809.598,4881.44141,2691.840,
3802.96118,2809.598,4881.53271,2691.840,
3803.05249,2810.598,4881.62451,2691.840,
3803.14404,2809.598,4881.71582,2690.840,
3803.23560,2810.598,4881.80762,2690.840,
3803.32715,2809.598,4881.89893,2690.840,
3803.41870,2810.598,4881.99072,2690.840,
3803.51025,2810.598,4882.08203,2690.840,
3803.60181,2810.598,4882.17334,2690.840,
3803.69312,2810.598,4882.26514,2689.840,
3803.78467,2811.598,4882.35645,2689.840,
3803.87622,2810.598,4882.44824,2689.840,
3803.96777,2811.598,4882.53955,2688.840,
3804.05933,2812.598,4882.63135,2689.840,
3804.15088,2812.598,4882.72266,2688.840,
3804.24243,2812.598,4882.81396,2688.840,
3804.33398,2813.598,4882.90576,2688.840,
3804.42529,2813.598,4882.99707,2688.840,
3804.51685,2813.598,4883.08887,2687.840,
3804.60840,2814.598,4883.18018,2687.840,
3804.69995,2814.598,4883.27197,2687.840,
3804.79150,2814.598,4883.36328,2687.840,
3804.88306,2814.598,4883.45508,2687.840,
3804.97461,2814.598,4883.54639,2687.840,
3805.06616,2813.598,4883.63770,2687.840,
3805.15747,2813.598,4883.72949,2687.840,
3805.24902,2814.598,4883.82080,2687.840,
3805.34058,2813.598,4883.91260,2686.840,
3805.43213,2814.598,4884.00391,2686.840,
3805.52368,2813.598,4884.09570,2686.840,
3805.61523,2814.598,4884.18701,2686.840,
3805.70679,2813.598,4884.27832,2685.840,
3805.79810,2813.598,4884.37012,2685.840,
3805.88965,2813.598,4884.46143,2685.840,
3805.98120,2813.598,4884.55322,2685.840,
3806.07275,2813.598,4884.64453,2684.840,
3806.16431,2813.598,4884.73633,2684.840,
3806.25586,2813.598,4884.82764,2684.840,
3806.34741,2814.598,4884.91895,2684.840,
3806.43896,2815.598,4885.01074,2683.840,
3806.53027,2816.598,4885.10205,2684.840,
3806.62183,2816.598,4885.19385,2683.840,
3806.71338,2818.598,4885.28516,2683.840,
3806.80493,2818.598,4885.37695,2682.840,
3806.89648,2817.598,4885.46826,2683.840,
3806.98804,2818.598,4885.56006,2682.840,
3807.07959,2818.598,4885.65137,2682.840,
3807.17090,2817.598,4885.74268,2682.840,
3807.26245,2817.598,4885.83447,2682.840,
3807.35400,2817.598,4885.92578,2682.840,
3807.44556,2817.598,4886.01758,2682.840,
3807.53711,2816.598,4886.10889,2681.840,
3807.62866,2816.598,4886.20068,2681.840,
3807.72021,2816.598,4886.29199,2680.840,
3807.81177,2816.598,4886.38330,2679.840,
3807.90308,2816.598,4886.47510,2679.840,
3807.99463,2816.598,4886.56641,2679.840,
3808.08618,2816.598,4886.65820,2679.840,
3808.17773,2816.598,4886.74951,2679.840,
3808.26929,2816.598,4886.84131,2680.840,
3808.36084,2816.598,4886.93262,2680.840,
3808.45239,2816.598,4887.02393,2679.840,
3808.54395,2816.598,4887.11572,2680.840,
3808.63525,2816.598,4887.20703,2680.840,
3808.72681,2816.598,4887.29883,2680.840,
3808.81836,2816.598,4887.39014,2680.840,
3808.90991,2816.598,4887.48193,2679.840,
3809.00146,2816.598,4887.57324,2679.840,
3809.09302,2817.598,4887.66504,2679.840,
3809.18457,2817.598,4887.75635,2679.840,
3809.27588,2817.598,4887.84766,2679.840,
3809.36743,2817.598,4887.93945,2678.840,
3809.45898,2817.598,4888.03076,2678.840,
3809.55054,2817.598,4888.12256,2678.840,
3809.64209,2818.598,4888.21387,2677.840,
3809.73364,2817.598,4888.30566,2678.840,
3809.82520,2817.598,4888.39697,2677.840,
3809.91675,2817.598,4888.48828,2677.840,
3810.00806,2818.598,4888.58008,2677.840,
3810.09961,2818.598,4888.67139,2676.840,
3810.19116,2818.598,4888.76318,2676.840,
3810.28271,2818.598,4888.85449,2676.840,
3810.37427,2818.598,4888.94629,2676.840,
3810.46582,2818.598,4889.03760,2676.840,
3810.55737,2818.598,4889.12891,2675.840,
3810.64893,2818.598,4889.22070,2675.840,
3810.74023,2818.598,4889.31201,2675.840,
3810.83179,2818.598,4889.40381,2675.840,
3810.92334,2818.598,4889.49512,2675.840,
3811.01489,2818.598,4889.58691,2675.840,
3811.10645,2819.598,4889.67822,2674.840,
3811.19800,2819.598,4889.77002,2674.840,
3811.28955,2818.598,4889.86133,2674.840,
3811.38086,2819.598,4889.95264,2673.840,
3811.47241,2819.598,4890.04443,2674.840,
3811.56396,2819.598,4890.13574,2673.840,
3811.65552,2819.598,4890.22754,2673.840,
3811.74707,2819.598,4890.31885,2674.840,
3811.83862,2819.598,4890.41064,2673.840,
3811.93018,2819.598,4890.50195,2673.840,
3812.02173,2819.598,4890.59326,2672.840,
3812.11304,2819.598,4890.68506,2672.840,
3812.20459,2820.598,4890.77637,2672.840,
3812.29614,2820.598,4890.86816,2672.840,
3812.38770,2820.598,4890.95947,2672.840,
3812.47925,2820.598,4891.05127,2671.840,
3812.57080,2821.598,4891.14258,2671.840,
3812.66235,2821.598,4891.23389,2671.840,
3812.75366,2820.598,4891.32568,2671.840,
3812.84521,2821.598,4891.41699,2670.840,
3812.93677,2821.598,4891.50879,2671.840,
3813.02832,2821.598,4891.60010,2671.840,
3813.11987,2821.598,4891.69189,2670.840,
3813.21143,2821.598,4891.78320,2671.840,
3813.30298,2821.598,4891.87500,2670.840,
3813.39453,2821.598,4891.96631,2670.840,
3813.48584,2821.598,4892.05762,2670.840,
3813.57739,2821.598,4892.14941,2670.840,
3813.66895,2822.598,4892.24072,2669.840,
3813.76050,2821.598,4892.33252,2669.840,
3813.85205,2822.598,4892.42383,2669.840,
3813.94360,2822.598,4892.51563,2669.840,
3814.03516,2823.598,4892.60693,2668.840,
3814.12671,2822.598,4892.69824,2668.840,
3814.21802,2823.598,4892.79004,2668.840,
3814.30957,2823.598,4892.88135,2667.840,
3814.40112,2823.598,4892.97314,2667.840,
3814.49268,2823.598,4893.06445,2667.840,
3814.58423,2823.598,4893.15625,2667.840,
3814.67578,2823.598,4893.24756,2667.840,
3814.76733,2823.598,4893.33887,2667.840,
3814.85864,2823.598,4893.43066,2666.840,
3814.95020,2823.598,4893.52197,2666.840,
3815.04175,2823.598,4893.61377,2666.840,
3815.13330,2823.598,4893.70508,2666.840,
3815.22485,2823.598,4893.79688,2666.840,
3815.31641,2823.598,4893.88818,2666.840,
3815.40796,2823.598,4893.97998,2665.840,
3815.49951,2824.598,4894.07129,2665.840,
3815.59082,2824.598,4894.16260,2665.840,
3815.68237,2824.598,4894.25439,2665.840,
3815.77393,2824.598,4894.34570,2665.840,
3815.86548,2825.598,4894.43750,2664.840,
3815.95703,2824.598,4894.52881,2664.840,
3816.04858,2824.598,4894.62061,2664.840,
3816.14014,2824.598,4894.71191,2664.840,
3816.23169,2825.598,4894.80322,2663.840,
3816.32300,2825.598,4894.89502,2663.840,
3816.41455,2825.598,4894.98633,2663.840,
3816.50610,2825.598,4895.07813,2663.840,
3816.59766,2825.598,4895.16943,2663.840,
3816.68921,2825.598,4895.26123,2662.840,
3816.78076,2825.598,4895.35254,2662.840,
3816.87231,2825.598,4895.44385,2663.840,
3816.96362,2825.598,4895.53564,2662.840,
3817.05518,2825.598,4895.62695,2662.840,
3817.14673,2826.598,4895.71875,2662.840,
3817.23828,2825.598,4895.81006,2661.840,
3817.32983,2826.598,4895.90186,2661.840,
3817.42139,2826.598,4895.99316,2661.840,
3817.51294,2826.598,4896.08447,2661.840,
3817.60449,2826.598,4896.17627,2661.840,
3817.69580,2826.598,4896.26758,2660.840,
3817.78735,2825.598,4896.35938,2660.840,
3817.87891,2826.598,4896.45068,2660.840,
3817.97046,2826.598,4896.54248,2660.840,
3818.06201,2826.598,4896.63379,2660.840,
3818.15356,2826.598,4896.72559,2659.840,
3818.24512,2827.598,4896.81689,2659.840,
3818.33667,2827.598,4896.90820,2659.840,
3818.42798,2827.598,4897.00000,2659.840,
3818.51953,2827.598,4897.09131,2659.840,
3818.61108,2827.598,4897.18311,2659.840,
3818.70264,2827.598,4897.27441,2658.840,
3818.79419,2827.598,4897.36621,2658.840,
3818.88574,2827.598,4897.45752,2658.840,
3818.97729,2827.598,4897.54883,2658.840,
3819.06860,2827.598,4897.64063,2658.840,
3819.16016,2827.598,4897.73193,2658.840,
3819.25171,2828.598,4897.82373,2657.840,
3819.34326,2827.598,4897.91504,2657.840,
3819.43481,2827.598,4898.00684,2656.840,
3819.52637,2828.598,4898.09814,2656.840,
3819.61792,2827.598,4898.18945,2657.840,
3819.70947,2828.598,4898.28125,2656.840,
3819.80078,2828.598,4898.37256,2656.840,
3819.89233,2828.598,4898.46436,2655.840,
3819.98389,2828.598,4898.55566,2656.840,
3820.07544,2828.598,4898.64746,2655.840,
3820.16699,2828.598,4898.73877,2655.840,
3820.25854,2828.598,4898.83057,2655.840,
3820.35010,2829.598,4898.92188,2654.840,
3820.44141,2828.598,4899.01318,2655.840,
3820.53296,2829.598,4899.10498,2655.840,
3820.62451,2829.598,4899.19629,2654.840,
3820.71606,2829.598,4899.28809,2654.840,
3820.80762,2829.598,4899.37939,2654.840,
3820.89917,2829.598,4899.47119,2653.840,
3820.99072,2829.598,4899.56250,2654.840,
3821.08228,2829.598,4899.65381,2653.840,
3821.17358,2829.598,4899.74561,2653.840,
3821.26514,2829.598,4899.83691,2653.840,
3821.35669,2830.598,4899.92871,2653.840,
3821.44824,2829.598,4900.02002,2653.840,
3821.53979,2830.598,4900.11182,2652.840,
3821.63135,2830.598,4900.20313,2652.840,
3821.72290,2830.598,4900.29443,2652.840,
3821.81445,2831.598,4900.38623,2652.840,
3821.90576,2831.598,4900.47754,2652.840,
3821.99731,2832.598,4900.56934,2652.840,
3822.08887,2832.598,4900.66064,2651.840,
3822.18042,2832.598,4900.75244,2651.840,
3822.27197,2832.598,4900.84375,2651.840,
3822.36353,2832.598,4900.93555,2651.840,
3822.45508,2832.598,4901.02686,2651.840,
3822.54639,2832.598,4901.11816,2650.840,
3822.63794,2832.598,4901.20996,2650.840,
3822.72949,2832.598,4901.30127,2650.840,
3822.82104,2833.598,4901.39307,2650.840,
3822.91260,2832.598,4901.48438,2649.840,
3823.00415,2833.598,4901.57617,2649.840,
3823.09570,2833.598,4901.66748,2649.840,
3823.18726,2832.598,4901.75879,2649.840,
3823.27856,2832.598,4901.85059,2649.840,
3823.37012,2833.598,4901.94189,2648.840,
3823.46167,2832.598,4902.03369,2649.840,
3823.55322,2832.598,4902.12500,2648.840,
3823.64478,2832.598,4902.21680,2647.840,
3823.73633,2832.598,4902.30811,2647.840,
3823.82788,2832.598,4902.39941,2647.840,
3823.91943,2833.598,4902.49121,2646.840,
3824.01074,2833.598,4902.58252,2646.840,
3824.10229,2834.598,4902.67432,2646.840,
3824.19385,2834.598,4902.76563,2646.840,
3824.28540,2835.598,4902.85742,2646.840,
3824.37695,2836.598,4902.94873,2645.840,
3824.46851,2836.598,4903.04053,2645.840,
3824.56006,2837.598,4903.13184,2645.840,
3824.65137,2836.598,4903.22314,2645.840,
3824.74292,2836.598,4903.31494,2645.840,
3824.83447,2836.598,4903.40625,2645.840,
3824.92603,2836.598,4903.49805,2645.840,
3825.01758,2836.598,4903.58936,2645.840,
3825.10913,2836.598,4903.68115,2645.840,
3825.20068,2835.598,4903.77246,2645.840,
3825.29224,2835.598,4903.86377,2645.840,
3825.38354,2836.598,4903.95557,2644.840,
3825.47510,2835.598,4904.04688,2645.840,
3825.56665,2835.598,4904.13867,2644.840,
3825.65820,2835.598,4904.22998,2644.840,
3825.74976,2835.598,4904.32178,2643.840,
3825.84131,2835.598,4904.41309,2643.840,
3825.93286,2835.598,4904.50439,2643.840,
3826.02417,2834.598,4904.59619,2644.840,
3826.11572,2834.598,4904.68750,2643.840,
3826.20728,2834.598,4904.77930,2643.840,
3826.29883,2834.598,4904.87061,2643.840,
3826.39038,2834.598,4904.96240,2643.840,
3826.48193,2834.598,4905.05371,2642.840,
3826.57349,2835.598,4905.14551,2641.840,
3826.66504,2834.598,4905.23682,2641.840,
3826.75635,2835.598,4905.32813,2640.840,
3826.84790,2835.598,4905.41992,2640.840,
3826.93945,2835.598,4905.51123,2640.840,
3827.03101,2835.598,4905.60303,2639.840,
3827.12256,2835.598,4905.69434,2639.840,
3827.21411,2835.598,4905.78613,2638.840,
3827.30566,2836.598,4905.87744,2638.840,
3827.39722,2836.598,4905.96875,2638.840,
3827.48853,2836.598,4906.06055,2638.840,
3827.58008,2836.598,4906.15186,2638.840,
3827.67163,2836.598,4906.24365,2638.840,
3827.76318,2836.598,4906.33496,2638.840,
3827.85474,2836.598,4906.42676,2638.840,
3827.94629,2836.598,4906.51807,2637.840,
3828.03784,2836.598,4906.60938,2638.840,
3828.12915,2836.598,4906.70117,2637.840,
3828.22070,2836.598,4906.79248,2637.840,
3828.31226,2836.598,4906.88428,2637.840,
3828.40381,2836.598,4906.97559,2637.840,
3828.49536,2836.598,4907.06738,2637.840,
3828.58691,2837.598,4907.15869,2637.840,
3828.67847,2837.598,4907.25000,2636.840,
3828.77002,2836.598,4907.34180,2636.840,
3828.86133,2836.598,4907.43311,2636.840,
3828.95288,2836.598,4907.52490,2636.840,
3829.04443,2837.598,4907.61621,2636.840,
3829.13599,2837.598,4907.70801,2635.840,
3829.22754,2837.598,4907.79932,2635.840,
3829.31909,2837.598,4907.89111,2635.840,
3829.41064,2837.598,4907.98242,2635.840,
3829.50220,2837.598,4908.07373,2634.840,
3829.59351,2837.598,4908.16553,2635.840,
3829.68506,2837.598,4908.25684,2634.840,
3829.77661,2837.598,4908.34863,2634.840,
3829.86816,2838.598,4908.43994,2634.840,
3829.95972,2837.598,4908.53174,2634.840,
3830.05127,2837.598,4908.62305,2634.840,
3830.14282,2838.598,4908.71436,2633.840,
3830.23413,2838.598,4908.80615,2633.840,
3830.32568,2838.598,4908.89746,2633.840,
3830.41724,2838.598,4908.98926,2633.840,
3830.50879,2838.598,4909.08057,2633.840,
3830.60034,2839.598,4909.17236,2633.840,
3830.69189,2839.598,4909.26367,2632.840,
3830.78345,2839.598,4909.35498,2633.840,
3830.87500,2839.598,4909.44678,2632.840,
3830.96631,2839.598,4909.53809,2632.840,
3831.05786,2839.598,4909.62988,2631.840,
3831.14941,2839.598,4909.72119,2631.840,
3831.24097,2839.598,4909.81299,2631.840,
3831.33252,2839.598,4909.90430,2631.840,
3831.42407,2839.598,4909.99609,2631.840,
3831.51563,2839.598,4910.08740,2630.840,
3831.60693,2840.598,4910.17871,2630.840,
3831.69849,2839.598,4910.27051,2630.840,
3831.79004,2839.598,4910.36182,2630.840,
3831.88159,2839.598,4910.45361,2629.840,
3831.97314,2840.598,4910.54492,2629.840,
3832.06470,2839.598,4910.63672,2629.840,
3832.15625,2839.598,4910.72803,2629.840,
3832.24780,2840.598,4910.81934,2629.840,
3832.33911,2840.598,4910.91113,2629.840,
3832.43066,2840.598,4911.00244,2628.840,
3832.52222,2840.598,4911.09424,2628.840,
3832.61377,2840.598,4911.18555,2628.840,
3832.70532,2840.598,4911.27734,2628.840,
3832.79688,2840.598,4911.36865,2628.840,
3832.88843,2840.598,4911.45996,2627.840,
3832.97998,2840.598,4911.55176,2627.840,
3833.07129,2841.598,4911.64307,2627.840,
3833.16284,2841.598,4911.73486,2627.840,
3833.25439,2841.598,4911.82617,2626.840,
3833.34595,2841.598,4911.91797,2626.840,
3833.43750,2841.598,4912.00928,2626.840,
3833.52905,2841.598,4912.10107,2626.840,
3833.62061,2841.598,4912.19238,2626.840,
3833.71191,2842.598,4912.28369,2626.840,
3833.80347,2841.598,4912.37549,2625.840,
3833.89502,2841.598,4912.46680,2625.840,
3833.98657,2841.598,4912.55859,2625.840,
3834.07813,2841.598,4912.64990,2625.840,
3834.16968,2841.598,4912.74170,2624.840,
3834.26123,2842.598,4912.83301,2624.840,
3834.35278,2842.598,4912.92432,2624.840,
3834.44409,2842.598,4913.01611,2624.840,
3834.53564,2842.598,4913.10742,2623.840,
3834.62720,2842.598,4913.19922,2623.840,
3834.71875,2842.598,4913.29053,2623.840,
3834.81030,2842.598,4913.38232,2623.840,
3834.90186,2843.598,4913.47363,2622.840,
3834.99341,2842.598,4913.56494,2622.840,
3835.08496,2842.598,4913.65674,2622.840,
3835.17627,2843.598,4913.74805,2622.840,
3835.26782,2843.598,4913.83984,2622.840,
3835.35938,2843.598,4913.93115,2622.840,
3835.45093,2843.598,4914.02295,2621.840,
3835.54248,2843.598,4914.11426,2621.840,
3835.63403,2842.598,4914.20605,2621.840,
3835.72559,2843.598,4914.29736,2621.840,
3835.81689,2843.598,4914.38867,2621.840,
3835.90845,2843.598,4914.48047,2621.840,
3836.00000,2844.598,4914.57178,2620.840,
3836.09155,2843.598,4914.66357,2620.840,
3836.18311,2843.598,4914.75488,2620.840,
3836.27466,2843.598,4914.84668,2620.840,
3836.36621,2844.598,4914.93799,2619.840,
3836.45776,2843.598,4915.02930,2619.840,
3836.54907,2844.598,4915.12109,2619.840,
3836.64063,2844.598,4915.21240,2619.840,
3836.73218,2844.598,4915.30420,2619.840,
3836.82373,2844.598,4915.39551,2618.840,
3836.91528,2844.598,4915.48730,2618.840,
3837.00684,2844.598,4915.57861,2618.840,
3837.09839,2844.598,4915.66992,2618.840,
3837.18994,2844.598,4915.76172,2618.840,
3837.28125,2844.598,4915.85303,2617.840,
3837.37280,2844.598,4915.94482,2617.840,
3837.46436,2845.598,4916.03613,2617.840,
3837.55591,2845.598,4916.12793,2617.840,
3837.64746,2845.598,4916.21924,2617.840,
3837.73901,2845.598,4916.31104,2617.840,
3837.83057,2845.598,4916.40234,2616.840,
3837.92188,2845.598,4916.49365,2616.840,
3838.01343,2845.598,4916.58545,2616.840,
3838.10498,2845.598,4916.67676,2616.840,
3838.19653,2845.598,4916.76855,2615.840,
3838.28809,2845.598,4916.85986,2615.840,
3838.37964,2845.598,4916.95166,2615.840,
3838.47119,2845.598,4917.04297,2615.840,
3838.56274,2846.598,4917.13428,2615.840,
3838.65405,2846.598,4917.22607,2614.840,
3838.74561,2845.598,4917.31738,2614.840,
3838.83716,2846.598,4917.40918,2614.840,
3838.92871,2846.598,4917.50049,2614.840,
3839.02026,2846.598,4917.59229,2613.840,
3839.11182,2846.598,4917.68359,2614.840,
3839.20337,2845.598,4917.77490,2613.840,
3839.29468,2846.598,4917.86670,2613.840,
3839.38623,2845.598,4917.95801,2612.840,
3839.47778,2845.598,4918.04980,2612.840,
3839.56934,2844.598,4918.14111,2613.840,
3839.66089,2844.598,4918.23291,2612.840,
3839.75244,2844.598,4918.32422,2612.840,
3839.84399,2844.598,4918.41602,2612.840,
3839.93555,2844.598,4918.50732,2611.840,
3840.02686,2844.598,4918.59863,2611.840,
3840.11841,2844.598,4918.69043,2611.840,
3840.20996,2844.598,4918.78174,2611.840,
3840.30151,2844.598,4918.87354,2611.840,
3840.39307,2845.598,4918.96484,2610.840,
3840.48462,2845.598,4919.05664,2610.840,
3840.57617,2845.598,4919.14795,2610.840,
3840.66772,2846.598,4919.23926,2610.840,
3840.75903,2846.598,4919.33105,2609.840,
3840.85059,2846.598,4919.42236,2609.840,
3840.94214,2846.598,4919.51416,2609.840,
3841.03369,2847.598,4919.60547,2609.840,
3841.12524,2847.598,4919.69727,2608.840,
3841.21680,2847.598,4919.78857,2608.840,
3841.30835,2847.598,4919.87988,2608.840,
3841.39966,2848.598,4919.97168,2607.840,
3841.49121,2848.598,4920.06299,2608.840,
3841.58276,2848.598,4920.15479,2608.840,
3841.67432,2848.598,4920.24609,2607.840,
3841.76587,2848.598,4920.33789,2607.840,
3841.85742,2848.598,4920.42920,2607.840,
3841.94897,2847.598,4920.52051,2606.840,
3842.04053,2847.598,4920.61230,2606.840,
3842.13184,2848.598,4920.70361,2605.840,
3842.22339,2847.598,4920.79541,2605.840,
3842.31494,2847.598,4920.88672,2605.840,
3842.40649,2847.598,4920.97852,2605.840,
3842.49805,2846.598,4921.06982,2605.840,
3842.58960,2847.598,4921.16162,2604.840,
3842.68115,2846.598,4921.25293,2604.840,
3842.77271,2847.598,4921.34424,2604.840,
3842.86401,2847.598,4921.43604,2603.840,
3842.95557,2847.598,4921.52734,2603.840,
3843.04712,2847.598,4921.61914,2604.840,
3843.13867,2848.598,4921.71045,2603.840,
3843.23022,2848.598,4921.80225,2604.840,
3843.32178,2848.598,4921.89355,2603.840,
3843.41333,2848.598,4921.98486,2604.840,
3843.50464,2849.598,4922.07666,2603.840,
3843.59619,2849.598,4922.16797,2603.840,
3843.68774,2849.598,4922.25977,2603.840,
3843.77930,2850.598,4922.35107,2602.840,
3843.87085,2850.598,4922.44287,2603.840,
3843.96240,2850.598,4922.53418,2603.840,
3844.05396,2850.598,4922.62549,2602.840,
3844.14551,2850.598,4922.71729,2603.840,
3844.23682,2851.598,4922.80859,2603.840,
3844.32837,2850.598,4922.90039,2603.840,
3844.41992,2850.598,4922.99170,2604.840,
3844.51147,2850.598,4923.08350,2603.840,
3844.60303,2851.598,4923.17480,2603.840,
3844.69458,2851.598,4923.26660,2602.840,
3844.78613,2852.598,4923.35791,2601.840,
3844.87744,2851.598,4923.44922,2601.840,
3844.96899,2851.598,4923.54102,2600.840,
3845.06055,2851.598,4923.63232,2600.840,
3845.15210,2851.598,4923.72412,2600.840,
3845.24365,2851.598,4923.81543,2599.840,
3845.33521,2852.598,4923.90723,2598.840,
3845.42676,2851.598,4923.99854,2599.840,
3845.51831,2851.598,4924.08984,2598.840,
3845.60962,2852.598,4924.18164,2598.840,
3845.70117,2852.598,4924.27295,2597.840,
3845.79272,2852.598,4924.36475,2597.840,
3845.88428,2852.598,4924.45605,2597.840,
3845.97583,2852.598,4924.54785,2597.840,
3846.06738,2852.598,4924.63916,2597.840,
3846.15894,2851.598,4924.73047,2597.840,
3846.25049,2853.598,4924.82227,2596.840,
3846.34180,2852.598,4924.91357,2596.840,
3846.43335,2852.598,4925.00537,2596.840,
3846.52490,2852.598,4925.09668,2596.840,
3846.61646,2853.598,4925.18848,2596.840,
3846.70801,2853.598,4925.27979,2596.840,
3846.79956,2853.598,4925.37158,2596.840,
3846.89111,2853.598,4925.46289,2596.840,
3846.98242,2853.598,4925.55420,2596.840,
3847.07397,2853.598,4925.64600,2595.840,
3847.16553,2853.598,4925.73730,2595.840,
3847.25708,2852.598,4925.82910,2595.840,
3847.34863,2853.598,4925.92041,2594.840,
3847.44019,2853.598,4926.01221,2595.840,
3847.53174,2853.598,4926.10352,2594.840,
3847.62329,2853.598,4926.19482,2593.840,
3847.71460,2854.598,4926.28662,2594.840,
3847.80615,2853.598,4926.37793,2593.840,
3847.89771,2853.598,4926.46973,2593.840,
3847.98926,2853.598,4926.56104,2593.840,
3848.08081,2854.598,4926.65283,2593.840,
3848.17236,2853.598,4926.74414,2592.840,
3848.26392,2854.598,4926.83545,2592.840,
3848.35547,2854.598,4926.92725,2592.840,
3848.44678,2854.598,4927.01855,2592.840,
3848.53833,2854.598,4927.11035,2591.840,
3848.62988,2854.598,4927.20166,2591.840,
3848.72144,2854.598,4927.29346,2591.840,
3848.81299,2854.598,4927.38477,2591.840,
3848.90454,2855.598,4927.47656,2591.840,
3848.99609,2855.598,4927.56787,2591.840,
3849.08740,2854.598,4927.65918,2591.840,
3849.17896,2856.598,4927.75098,2590.840,
3849.27051,2854.598,4927.84229,2590.840,
3849.36206,2854.598,4927.93408,2590.840,
3849.45361,2855.598,4928.02539,2589.840,
3849.54517,2855.598,4928.11719,2589.840,
3849.63672,2855.598,4928.20850,2589.840,
3849.72827,2855.598,4928.29980,2589.840,
3849.81958,2855.598,4928.39160,2589.840,
3849.91113,2855.598,4928.48291,2589.840,
3850.00269,2855.598,4928.57471,2588.840,
3850.09424,2855.598,4928.66602,2588.840,
3850.18579,2855.598,4928.75781,2588.840,
3850.27734,2856.598,4928.84912,2587.840,
3850.36890,2855.598,4928.94043,2588.840,
3850.46021,2855.598,4929.03223,2587.840,
3850.55176,2855.598,4929.12354,2587.840,
3850.64331,2856.598,4929.21533,2587.840,
3850.73486,2856.598,4929.30664,2587.840,
3850.82642,2856.598,4929.39844,2586.840,
3850.91797,2856.598,4929.48975,2586.840,
3851.00952,2856.598,4929.58154,2586.840,
3851.10107,2855.598,4929.67285,2586.840,
3851.19238,2856.598,4929.76416,2585.840,
3851.28394,2856.598,4929.85596,2586.840,
3851.37549,2856.598,4929.94727,2585.840,
3851.46704,2856.598,4930.03906,2585.840,
3851.55859,2856.598,4930.13037,2585.840,
3851.65015,2856.598,4930.22217,2585.840,
3851.74170,2856.598,4930.31348,2585.840,
3851.83325,2857.598,4930.40479,2584.840,
3851.92456,2856.598,4930.49658,2584.840,
3852.01611,2856.598,4930.58789,2584.840,
3852.10767,2857.598,4930.67969,2583.840,
3852.19922,2857.598,4930.77100,2583.840,
3852.29077,2857.598,4930.86279,2583.840,
3852.38232,2857.598,4930.95410,2583.840,
3852.47388,2857.598,4931.04541,2582.840,
3852.56519,2857.598,4931.13721,2582.840,
3852.65674,2857.598,4931.22852,2582.840,
3852.74829,2857.598,4931.32031,2582.840,
3852.83984,2857.598,4931.41162,2581.840,
3852.93140,2858.598,4931.50342,2581.840,
3853.02295,2857.598,4931.59473,2581.840,
3853.11450,2858.598,4931.68652,2581.840,
3853.20605,2857.598,4931.77783,2581.840,
3853.29736,2858.598,4931.86914,2580.840,
3853.38892,2857.598,4931.96094,2580.840,
3853.48047,2858.598,4932.05225,2580.840,
3853.57202,2858.598,4932.14404,2580.840,
3853.66357,2858.598,4932.23535,2579.840,
3853.75513,2858.598,4932.32715,2579.840,
3853.84668,2858.598,4932.41846,2579.840,
3853.93823,2858.598,4932.50977,2579.840,
3854.02954,2858.598,4932.60156,2579.840,
3854.12109,2858.598,4932.69287,2578.840,
3854.21265,2859.598,4932.78467,2579.840,
3854.30420,2858.598,4932.87598,2578.840,
3854.39575,2859.598,4932.96777,2578.840,
3854.48730,2859.598,4933.05908,2577.840,
3854.57886,2859.598,4933.15039,2578.840,
3854.67017,2859.598,4933.24219,2577.840,
3854.76172,2859.598,4933.33350,2577.840,
3854.85327,2859.598,4933.42529,2577.840,
3854.94482,2859.598,4933.51660,2577.840,
3855.03638,2860.598,4933.60840,2576.840,
3855.12793,2859.598,4933.69971,2576.840,
3855.21948,2859.598,4933.79102,2576.840,
3855.31104,2859.598,4933.88281,2576.840,
3855.40234,2859.598,4933.97412,2575.840,
3855.49390,2859.598,4934.06592,2575.840,
3855.58545,2859.598,4934.15723,2574.840,
3855.67700,2860.598,4934.24902,2575.840,
3855.76855,2859.598,4934.34033,2575.840,
3855.86011,2859.598,4934.43213,2574.840,
3855.95166,2860.598,4934.52344,2574.840,
3856.04321,2860.598,4934.61475,2574.840,
3856.13452,2860.598,4934.70654,2574.840,
3856.22607,2860.598,4934.79785,2573.840,
3856.31763,2860.598,4934.88965,2573.840,
3856.40918,2860.598,4934.98096,2573.840,
3856.50073,2861.598,4935.07275,2573.840,
3856.59229,2860.598,4935.16406,2572.840,
3856.68384,2860.598,4935.25537,2572.840,
3856.77515,2860.598,4935.34717,2572.840,
3856.86670,2860.598,4935.43848,2571.840,
3856.95825,2860.598,4935.53027,2572.840,
3857.04980,2860.598,4935.62158,2571.840,
3857.14136,2860.598,4935.71338,2571.840,
3857.23291,2860.598,4935.80469,2571.840,
3857.32446,2859.598,4935.89600,2571.840,
3857.41602,2859.598,4935.98779,2570.840,
3857.50732,2859.598,4936.07910,2569.840,
3857.59888,2859.598,4936.17090,2570.840,
3857.69043,2859.598,4936.26221,2569.840,
3857.78198,2859.598,4936.35400,2569.840,
3857.87354,2860.598,4936.44531,2569.840,
3857.96509,2860.598,4936.53711,2569.840,
3858.05664,2860.598,4936.62842,2569.840,
3858.14795,2860.598,4936.71973,2569.840,
3858.23950,2860.598,4936.81152,2569.840,
3858.33105,2861.598,4936.90283,2568.840,
3858.42261,2861.598,4936.99463,2568.840,
3858.51416,2861.598,4937.08594,2567.840,
3858.60571,2861.598,4937.17773,2568.840,
3858.69727,2862.598,4937.26904,2567.840,
3858.78882,2861.598,4937.36035,2567.840,
3858.88013,2862.598,4937.45215,2566.840,
3858.97168,2862.598,4937.54346,2567.840,
3859.06323,2862.598,4937.63525,2566.840,
3859.15479,2861.598,4937.72656,2566.840,
3859.24634,2862.598,4937.81836,2565.840,
3859.33789,2861.598,4937.90967,2565.840,
3859.42944,2862.598,4938.00098,2565.840,
3859.52100,2862.598,4938.09277,2564.840,
3859.61230,2861.598,4938.18408,2563.840,
3859.70386,2861.598,4938.27588,2562.840,
3859.79541,2861.598,4938.36719,2562.840,
3859.88696,2861.598,4938.45898,2561.840,
3859.97852,2861.598,4938.55029,2561.840,
3860.07007,2862.598,4938.64209,2561.840,
3860.16162,2862.598,4938.73340,2561.840,
3860.25293,2861.598,4938.82471,2561.840,
3860.34448,2862.598,4938.91650,2561.840,
3860.43604,2862.598,4939.00781,2561.840,
3860.52759,2862.598,4939.09961,2560.840,
3860.61914,2863.598,4939.19092,2561.840,
3860.71069,2863.598,4939.28271,2560.840,
3860.80225,2863.598,4939.37402,2561.840,
3860.89380,2864.598,4939.46533,2560.840,
3860.98511,2863.598,4939.55713,2560.840,
3861.07666,2863.598,4939.64844,2560.840,
3861.16821,2864.598,4939.74023,2560.840,
3861.25977,2864.598,4939.83154,2560.840,
3861.35132,2864.598,4939.92334,2559.840,
3861.44287,2864.598,4940.01465,2560.840,
3861.53442,2864.598,4940.10596,2561.840,
3861.62598,2864.598,4940.19775,2560.840,
3861.71729,2864.598,4940.28906,2560.840,
3861.80884,2865.598,4940.38086,2559.840,
3861.90039,2864.598,4940.47217,2560.840,
3861.99194,2864.598,4940.56396,2560.840,
3862.08350,2864.598,4940.65527,2560.840,
3862.17505,2865.598,4940.74707,2560.840,
3862.26660,2864.598,4940.83838,2559.840,
3862.35791,2865.598,4940.92969,2559.840,
3862.44946,2865.598,4941.02148,2558.840,
3862.54102,2864.598,4941.11279,2558.840,
3862.63257,2864.598,4941.20459,2557.840,
3862.72412,2865.598,4941.29590,2556.840,
3862.81567,2864.598,4941.38770,2556.840,
3862.90723,2864.598,4941.47900,2556.840,
3862.99878,2864.598,4941.57031,2556.840,
3863.09009,2864.598,4941.66211,2555.840,
3863.18164,2865.598,4941.75342,2555.840,
3863.27319,2864.598,4941.84521,2555.840,
3863.36475,2864.598,4941.93652,2555.840,
3863.45630,2865.598,4942.02832,2555.840,
3863.54785,2865.598,4942.11963,2554.840,
3863.63940,2865.598,4942.21094,2554.840,
3863.73071,2865.598,4942.30273,2553.840,
3863.82227,2865.598,4942.39404,2553.840,
3863.91382,2865.598,4942.48584,2554.840,
3864.00537,2865.598,4942.57715,2553.840,
3864.09692,2866.598,4942.66895,2553.840,
3864.18848,2865.598,4942.76025,2553.840,
3864.28003,2866.598,4942.85205,2553.840,
3864.37158,2865.598,4942.94336,2553.840,
3864.46289,2865.598,4943.03467,2553.840,
3864.55444,2866.598,4943.12646,2553.840,
3864.64600,2865.598,4943.21777,2552.840,
3864.73755,2865.598,4943.30957,2552.840,
3864.82910,2866.598,4943.40088,2552.840,
3864.92065,2866.598,4943.49268,2551.840,
3865.01221,2866.598,4943.58398,2552.840,
3865.10376,2866.598,4943.67529,2551.840,
3865.19507,2866.598,4943.76709,2551.840,
3865.28662,2867.598,4943.85840,2551.840,
3865.37817,2866.598,4943.95020,2551.840,
3865.46973,2866.598,4944.04150,2550.840,
3865.56128,2866.598,4944.13330,2550.840,
3865.65283,2866.598,4944.22461,2550.840,
3865.74438,2867.598,4944.31592,2549.840,
3865.83569,2867.598,4944.40771,2549.840,
3865.92725,2866.598,4944.49902,2549.840,
3866.01880,2867.598,4944.59082,2549.840,
3866.11035,2867.598,4944.68213,2549.840,
3866.20190,2867.598,4944.77393,2548.840,
3866.29346,2867.598,4944.86523,2548.840,
3866.38501,2867.598,4944.95654,2548.840,
3866.47656,2867.598,4945.04834,2547.840,
3866.56787,2867.598,4945.13965,2548.840,
3866.65942,2867.598,4945.23145,2547.840,
3866.75098,2868.598,4945.32275,2547.840,
3866.84253,2867.598,4945.41455,2547.840,
3866.93408,2867.598,4945.50586,2546.840,
3867.02563,2867.598,4945.59766,2546.840,
3867.11719,2867.598,4945.68896,2546.840,
3867.20874,2867.598,4945.78027,2546.840,
3867.30005,2867.598,4945.87207,2545.840,
3867.39160,2867.598,4945.96338,2546.840,
3867.48315,2867.598,4946.05518,2545.840,
3867.57471,2867.598,4946.14648,2545.840,
3867.66626,2867.598,4946.23828,2545.840,
3867.75781,2867.598,4946.32959,2545.840,
3867.84937,2868.598,4946.42090,2545.840,
3867.94067,2867.598,4946.51270,2544.840,
3868.03223,2867.598,4946.60400,2544.840,
3868.12378,2867.598,4946.69580,2543.840,
3868.21533,2868.598,4946.78711,2543.840,
3868.30688,2868.598,4946.87891,2543.840,
3868.39844,2868.598,4946.97021,2543.840,
3868.48999,2869.598,4947.06152,2543.840,
3868.58154,2868.598,4947.15332,2543.840,
3868.67285,2869.598,4947.24463,2542.840,
3868.76440,2868.598,4947.33643,2542.840,
3868.85596,2869.598,4947.42773,2543.840,
3868.94751,2869.598,4947.51953,2542.840,
3869.03906,2869.598,4947.61084,2541.840,
3869.13062,2869.598,4947.70264,2541.840,
3869.22217,2868.598,4947.79395,2541.840,
3869.31348,2869.598,4947.88525,2541.840,
3869.40503,2869.598,4947.97705,2541.840,
3869.49658,2869.598,4948.06836,2540.840,
3869.58813,2869.598,4948.16016,2540.840,
3869.67969,2870.598,4948.25146,2539.840,
3869.77124,2869.598,4948.34326,2540.840,
3869.86279,2869.598,4948.43457,2539.840,
3869.95435,2870.598,4948.52588,2539.840,
3870.04565,2869.598,4948.61768,2539.840,
3870.13721,2870.598,4948.70898,2539.840,
3870.22876,2869.598,4948.80078,2538.840,
3870.32031,2870.598,4948.89209,2539.840,
3870.41187,2870.598,4948.98389,2538.840,
3870.50342,2870.598,4949.07520,2538.840,
3870.59497,2869.598,4949.16650,2537.840,
3870.68652,2870.598,4949.25830,2538.840,
3870.77783,2870.598,4949.34961,2537.840,
3870.86938,2870.598,4949.44141,2537.840,
3870.96094,2870.598,4949.53271,2537.840,
3871.05249,2870.598,4949.62451,2536.840,
3871.14404,2871.598,4949.71582,2536.840,
3871.23560,2870.598,4949.80762,2536.840,
3871.32715,2870.598,4949.89893,2536.840,
3871.41846,2870.598,4949.99023,2535.840,
3871.51001,2870.598,4950.08203,2535.840,
3871.60156,2870.598,4950.17334,2535.840,
3871.69312,2871.598,4950.26514,2534.840,
3871.78467,2870.598,4950.35645,2535.840,
3871.87622,2870.598,4950.44824,2534.840,
3871.96777,2870.598,4950.53955,2534.840,
3872.05933,2871.598,4950.63086,2534.840,
3872.15063,2871.598,4950.72266,2534.840,
3872.24219,2870.598,4950.81396,2533.840,
3872.33374,2871.598,4950.90576,2533.840,
3872.42529,2871.598,4950.99707,2533.840,
3872.51685,2871.598,4951.08887,2533.840,
3872.60840,2871.598,4951.18018,2532.840,
3872.69995,2871.598,4951.27148,2532.840,
3872.79150,2871.598,4951.36328,2532.840,
3872.88281,2871.598,4951.45459,2531.840,
3872.97437,2871.598,4951.54639,2531.840,
3873.06592,2871.598,4951.63770,2531.840,
3873.15747,2871.598,4951.72949,2531.840,
3873.24902,2871.598,4951.82080,2531.840,
3873.34058,2871.598,4951.91260,2531.840,
3873.43213,2871.598,4952.00391,2530.840,
3873.52344,2871.598,4952.09521,2530.840,
3873.61499,2871.598,4952.18701,2529.840,
3873.70654,2871.598,4952.27832,2529.840,
3873.79810,2871.598,4952.37012,2529.840,
3873.88965,2871.598,4952.46143,2529.840,
3873.98120,2871.598,4952.55322,2529.840,
3874.07275,2872.598,4952.64453,2528.840,
3874.16431,2872.598,4952.73584,2528.840,
3874.25562,2871.598,4952.82764,2528.840,
3874.34717,2871.598,4952.91895,2528.840,
3874.43872,2871.598,4953.01074,2527.840,
3874.53027,2872.598,4953.10205,2527.840,
3874.62183,2872.598,4953.19385,2527.840,
3874.71338,2872.598,4953.28516,2527.840,
3874.80493,2871.598,4953.37646,2527.840,
3874.89648,2871.598,4953.46826,2526.840,
3874.98779,2871.598,4953.55957,2526.840,
3875.07935,2871.598,4953.65137,2526.840,
3875.17090,2871.598,4953.74268,2526.840,
3875.26245,2870.598,4953.83447,2525.840,
3875.35400,2870.598,4953.92578,2526.840,
3875.44556,2870.598,4954.01758,2525.840,
3875.53711,2870.598,4954.10889,2524.840,
3875.62842,2870.598,4954.20020,2524.840,
3875.71997,2870.598,4954.29199,2524.840,
3875.81152,2870.598,4954.38330,2523.840,
3875.90308,2870.598,4954.47510,2523.840,
3875.99463,2870.598,4954.56641,2524.840,
3876.08618,2870.598,4954.65820,2523.840,
3876.17773,2871.598,4954.74951,2523.840,
3876.26929,2871.598,4954.84082,2523.840,
3876.36060,2871.598,4954.93262,2523.840,
3876.45215,2871.598,4955.02393,2522.840,
3876.54370,2871.598,4955.11572,2522.840,
3876.63525,2871.598,4955.20703,2522.840,
3876.72681,2872.598,4955.29883,2521.840,
3876.81836,2872.598,4955.39014,2521.840,
3876.90991,2872.598,4955.48145,2521.840,
3877.00122,2873.598,4955.57324,2521.840,
3877.09277,2873.598,4955.66455,2521.840,
3877.18433,2873.598,4955.75635,2520.840,
3877.27588,2873.598,4955.84766,2520.840,
3877.36743,2872.598,4955.93945,2520.840,
3877.45898,2872.598,4956.03076,2520.840,
3877.55054,2872.598,4956.12256,2520.840,
3877.64209,2872.598,4956.21387,2520.840,
3877.73340,2871.598,4956.30518,2520.840,
3877.82495,2870.598,4956.39697,2520.840,
3877.91650,2870.598,4956.48828,2520.840,
3878.00806,2869.598,4956.58008,2520.840,
3878.09961,2869.598,4956.67139,2519.840,
3878.19116,2869.598,4956.76318,2519.840,
3878.28271,2870.598,4956.85449,2519.840,
3878.37427,2870.598,4956.94580,2519.840,
3878.46558,2871.598,4957.03760,2518.840,
3878.55713,2871.598,4957.12891,2517.840,
3878.64868,2871.598,4957.22070,2517.840,
3878.74023,2871.598,4957.31201,2517.840,
3878.83179,2871.598,4957.40381,2517.840,
3878.92334,2872.598,4957.49512,2516.840,
3879.01489,2872.598,4957.58643,2516.840,
3879.10620,2872.598,4957.67822,2516.840,
3879.19775,2873.598,4957.76953,2515.840,
3879.28931,2873.598,4957.86133,2515.840,
3879.38086,2874.598,4957.95264,2515.840,
3879.47241,2873.598,4958.04443,2514.840,
3879.56396,2874.598,4958.13574,2514.840,
3879.65552,2874.598,4958.22705,2513.840,
3879.74707,2875.598,4958.31885,2512.840,
3879.83838,2874.598,4958.41016,2512.840,
3879.92993,2874.598,4958.50195,2512.840,
3880.02148,2874.598,4958.59326,2511.840,
3880.11304,2874.598,4958.68506,2512.840,
3880.20459,2874.598,4958.77637,2512.840,
3880.29614,2875.598,4958.86816,2512.840,
3880.38770,2874.598,4958.95947,2511.840,
3880.47925,2874.598,4959.05078,2512.840,
3880.57056,2875.598,4959.14258,2513.840,
3880.66211,2875.598,4959.23389,2512.840,
3880.75366,2874.598,4959.32568,2512.840,
3880.84521,2874.598,4959.41699,2512.840,
3880.93677,2875.598,4959.50879,2511.840,
3881.02832,2875.598,4959.60010,2511.840,
3881.11987,2874.598,4959.69141,2511.840,
3881.21118,2875.598,4959.78320,2510.840,
3881.30273,2874.598,4959.87451,2510.840,
3881.39429,2875.598,4959.96631,2510.840,
3881.48584,2875.598,4960.05762,2510.840,
3881.57739,2875.598,4960.14941,2509.840,
3881.66895,2875.598,4960.24072,2509.840,
3881.76050,2875.598,4960.33203,2509.840,
3881.85205,2875.598,4960.42383,2508.840,
3881.94336,2875.598,4960.51514,2508.840,
3882.03491,2875.598,4960.60693,2508.840,
3882.12646,2875.598,4960.69824,2508.840,
3882.21802,2875.598,4960.79004,2508.840,
3882.30957,2875.598,4960.88135,2507.840,
3882.40112,2876.598,4960.97314,2507.840,
3882.49268,2876.598,4961.06445,2506.840,
3882.58398,2876.598,4961.15576,2507.840,
3882.67554,2876.598,4961.24756,2506.840,
3882.76709,2876.598,4961.33887,2506.840,
3882.85864,2877.598,4961.43066,2506.840,
3882.95020,2876.598,4961.52197,2506.840,
3883.04175,2876.598,4961.61377,2505.840,
3883.13330,2876.598,4961.70508,2505.840,
3883.22485,2876.598,4961.79639,2505.840,
3883.31616,2876.598,4961.88818,2504.840,
3883.40771,2876.598,4961.97949,2504.840,
3883.49927,2876.598,4962.07129,2505.840,
3883.59082,2876.598,4962.16260,2504.840,
3883.68237,2876.598,4962.25439,2503.840,
3883.77393,2876.598,4962.34570,2503.840,
3883.86548,2876.598,4962.43701,2503.840,
3883.95703,2876.598,4962.52881,2503.840,
3884.04834,2877.598,4962.62012,2503.840,
3884.13989,2876.598,4962.71191,2502.840,
3884.23145,2877.598,4962.80322,2501.840,
3884.32300,2876.598,4962.89502,2501.840,
3884.41455,2877.598,4962.98633,2502.840,
3884.50610,2877.598,4963.07813,2501.840,
3884.59766,2876.598,4963.16943,2501.840,
3884.68896,2877.598,4963.26074,2501.840,
3884.78052,2877.598,4963.35254,2501.840,
3884.87207,2877.598,4963.44385,2500.840,
3884.96362,2877.598,4963.53564,2501.840,
3885.05518,2876.598,4963.62695,2500.840,
3885.14673,2877.598,4963.71875,2500.840,
3885.23828,2877.598,4963.81006,2499.840,
3885.32983,2877.598,4963.90137,2500.840,
3885.42114,2877.598,4963.99316,2499.840,
3885.51270,2877.598,4964.08447,2498.840,
3885.60425,2877.598,4964.17627,2498.840,
3885.69580,2877.598,4964.26758,2498.840,
3885.78735,2878.598,4964.35938,2497.840,
3885.87891,2878.598,4964.45068,2498.840,
3885.97046,2878.598,4964.54199,2497.840,
3886.06201,2877.598,4964.63379,2497.840,
3886.15332,2878.598,4964.72510,2497.840,
3886.24487,2878.598,4964.81689,2497.840,
3886.33643,2878.598,4964.90820,2496.840,
3886.42798,2878.598,4965.00000,2497.840,
3886.51953,2878.598,4965.09131,2496.840,
3886.61108,2878.598,4965.18311,2495.840,
3886.70264,2878.598,4965.27441,2495.840,
3886.79395,2878.598,4965.36572,2495.840,
3886.88550,2878.598,4965.45752,2495.840,
3886.97705,2877.598,4965.54883,2495.840,
3887.06860,2877.598,4965.64063,2494.840,
3887.16016,2878.598,4965.73193,2494.840,
3887.25171,2878.598,4965.82373,2494.840,
3887.34326,2877.598,4965.91504,2494.840,
3887.43481,2878.598,4966.00635,2493.840,
3887.52612,2878.598,4966.09814,2493.840,
3887.61768,2878.598,4966.18945,2493.840,
3887.70923,2878.598,4966.28125,2492.840,
3887.80078,2878.598,4966.37256,2492.840,
3887.89233,2878.598,4966.46436,2492.840,
3887.98389,2878.598,4966.55566,2492.840,
3888.07544,2878.598,4966.64697,2491.840,
3888.16675,2878.598,4966.73877,2492.840,
3888.25830,2878.598,4966.83008,2491.840,
3888.34985,2878.598,4966.92188,2491.840,
3888.44141,2879.598,4967.01318,2491.840,
3888.53296,2878.598,4967.10498,2491.840,
3888.62451,2878.598,4967.19629,2490.840,
3888.71606,2879.598,4967.28809,2490.840,
3888.80762,2878.598,4967.37939,2490.840,
3888.89893,2878.598,4967.47070,2489.840,
3888.99048,2879.598,4967.56250,2489.840,
3889.08203,2878.598,4967.65381,2489.840,
3889.17358,2879.598,4967.74561,2489.840,
3889.26514,2879.598,4967.83691,2488.840,
3889.35669,2879.598,4967.92871,2489.840,
3889.44824,2879.598,4968.02002,2488.840,
3889.53979,2879.598,4968.11133,2487.840,
3889.63110,2878.598,4968.20313,2488.840,
3889.72266,2879.598,4968.29443,2487.840,
3889.81421,2878.598,4968.38623,2487.840,
3889.90576,2879.598,4968.47754,2487.840,
3889.99731,2879.598,4968.56934,2487.840,
3890.08887,2879.598,4968.66064,2486.840,
3890.18042,2879.598,4968.75195,2486.840,
3890.27173,2879.598,4968.84375,2486.840,
3890.36328,2879.598,4968.93506,2485.840,
3890.45483,2879.598,4969.02686,2484.840,
3890.54639,2879.598,4969.11816,2485.840,
3890.63794,2879.598,4969.20996,2484.840,
3890.72949,2879.598,4969.30127,2484.840,
3890.82104,2879.598,4969.39258,2485.840,
3890.91260,2879.598,4969.48438,2484.840,
3891.00391,2879.598,4969.57568,2483.840,
3891.09546,2879.598,4969.66748,2483.840,
3891.18701,2879.598,4969.75879,2483.840,
3891.27856,2879.598,4969.85059,2483.840,
3891.37012,2879.598,4969.94189,2482.840,
3891.46167,2879.598,4970.03369,2483.840,
3891.55322,2879.598,4970.12500,2482.840,
3891.64478,2880.598,4970.21631,2482.840,
3891.73608,2879.598,4970.30811,2482.840,
3891.82764,2880.598,4970.39941,2482.840,
3891.91919,2880.598,4970.49121,2481.840,
3892.01074,2880.598,4970.58252,2481.840,
3892.10229,2880.598,4970.67432,2481.840,
3892.19385,2880.598,4970.76563,2480.840,
3892.28540,2880.598,4970.85693,2481.840,
3892.37671,2880.598,4970.94873,2481.840,
3892.46826,2880.598,4971.04004,2480.840,
3892.55981,2880.598,4971.13184,2479.840,
3892.65137,2880.598,4971.22314,2479.840,
3892.74292,2881.598,4971.31494,2479.840,
3892.83447,2881.598,4971.40625,2479.840,
3892.92603,2882.598,4971.49756,2479.840,
3893.01758,2882.598,4971.58936,2479.840,
3893.10889,2883.598,4971.68066,2478.840,
3893.20044,2883.598,4971.77246,2478.840,
3893.29199,2883.598,4971.86377,2478.840,
3893.38354,2883.598,4971.95557,2477.840,
3893.47510,2883.598,4972.04688,2477.840,
3893.56665,2883.598,4972.13867,2477.840,
3893.65820,2883.598,4972.22998,2477.840,
3893.74951,2883.598,4972.32129,2477.840,
3893.84106,2883.598,4972.41309,2476.840,
3893.93262,2882.598,4972.50439,2476.840,
3894.02417,2882.598,4972.59619,2476.840,
3894.11572,2882.598,4972.68750,2475.840,
3894.20728,2882.598,4972.77930,2475.840,
3894.29883,2881.598,4972.87061,2475.840,
3894.39038,2881.598,4972.96191,2474.840,
3894.48169,2881.598,4973.05371,2474.840,
3894.57324,2881.598,4973.14502,2474.840,
3894.66479,2881.598,4973.23682,2473.840,
3894.75635,2881.598,4973.32813,2473.840,
3894.84790,2881.598,4973.41992,2472.840,
3894.93945,2880.598,4973.51123,2471.840,
3895.03101,2881.598,4973.60254,2471.840,
3895.12256,2881.598,4973.69434,2470.840,
3895.21387,2881.598,4973.78564,2470.840,
3895.30542,2882.598,4973.87744,2469.840,
3895.39697,2882.598,4973.96875,2469.840,
3895.48853,2883.598,4974.06055,2469.840,
3895.58008,2882.598,4974.15186,2469.840,
3895.67163,2883.598,4974.24365,2468.840,
3895.76318,2882.598,4974.33496,2468.840,
3895.85449,2882.598,4974.42627,2468.840,
3895.94604,2881.598,4974.51807,2468.840,
3896.03760,2882.598,4974.60938,2468.840,
3896.12915,2881.598,4974.70117,2468.840,
3896.22070,2881.598,4974.79248,2468.840,
3896.31226,2881.598,4974.88428,2468.840,
3896.40381,2881.598,4974.97559,2468.840,
3896.49536,2881.598,4975.06689,2468.840,
3896.58667,2881.598,4975.15869,2468.840,
3896.67822,2881.598,4975.25000,2469.840,
3896.76978,2881.598,4975.34180,2467.840,
3896.86133,2881.598,4975.43311,2468.840,
3896.95288,2881.598,4975.52490,2468.840,
3897.04443,2881.598,4975.61621,2468.840,
3897.13599,2881.598,4975.70752,2467.840,
3897.22754,2881.598,4975.79932,2468.840,
3897.31885,2880.598,4975.89063,2467.840,
3897.41040,2881.598,4975.98242,2468.840,
3897.50195,2882.598,4976.07373,2467.840,
3897.59351,2881.598,4976.16553,2467.840,
3897.68506,2881.598,4976.25684,2467.840,
3897.77661,2881.598,4976.34863,2467.840,
3897.86816,2881.598,4976.43994,2466.840,
3897.95947,2881.598,4976.53125,2466.840,
3898.05103,2881.598,4976.62305,2465.840,
3898.14258,2881.598,4976.71436,2465.840,
3898.23413,2881.598,4976.80615,2464.840,
3898.32568,2881.598,4976.89746,2464.840,
3898.41724,2881.598,4976.98926,2463.840,
3898.50879,2881.598,4977.08057,2462.840,
3898.60034,2881.598,4977.17188,2462.840,
3898.69165,2881.598,4977.26367,2462.840,
3898.78320,2882.598,4977.35498,2461.840,
3898.87476,2882.598,4977.44678,2462.840,
3898.96631,2883.598,4977.53809,2461.840,
3899.05786,2882.598,4977.62988,2461.840,
3899.14941,2881.598,4977.72119,2461.840,
3899.24097,2882.598,4977.81250,2461.840,
3899.33252,2882.598,4977.90430,2461.840,
3899.42383,2882.598,4977.99561,2460.840,
3899.51538,2882.598,4978.08740,2460.840,
3899.60693,2882.598,4978.17871,2461.840,
3899.69849,2882.598,4978.27051,2460.840,
3899.79004,2882.598,4978.36182,2459.840,
3899.88159,2882.598,4978.45361,2460.840,
3899.97314,2882.598,4978.54492,2460.840,
3900.06445,2882.598,4978.63623,2459.840,
3900.15601,2882.598,4978.72803,2459.840,
3900.24756,2882.598,4978.81934,2459.840,
3900.33911,2882.598,4978.91113,2458.840,
3900.43066,2882.598,4979.00244,2458.840,
3900.52222,2882.598,4979.09424,2458.840,
3900.61377,2882.598,4979.18555,2457.840,
3900.70532,2882.598,4979.27686,2457.840,
3900.79663,2882.598,4979.36865,2457.840,
3900.88818,2882.598,4979.45996,2457.840,
3900.97974,2882.598,4979.55176,2456.840,
3901.07129,2882.598,4979.64307,2457.840,
3901.16284,2882.598,4979.73486,2457.840,
3901.25439,2882.598,4979.82617,2456.840,
3901.34595,2882.598,4979.91748,2456.840,
3901.43726,2882.598,4980.00928,2456.840,
3901.52881,2882.598,4980.10059,2456.840,
3901.62036,2882.598,4980.19238,2455.840,
3901.71191,2882.598,4980.28369,2455.840,
3901.80347,2882.598,4980.37549,2454.840,
3901.89502,2883.598,4980.46680,2454.840,
3901.98657,2883.598,4980.55859,2455.840,
3902.07813,2882.598,4980.64990,2454.840,
3902.16943,2883.598,4980.74121,2453.840,
3902.26099,2882.598,4980.83301,2453.840,
3902.35254,2883.598,4980.92432,2453.840,
3902.44409,2883.598,4981.01611,2453.840,
3902.53564,2883.598,4981.10742,2453.840,
3902.62720,2882.598,4981.19922,2452.840,
3902.71875,2882.598,4981.29053,2452.840,
3902.81030,2882.598,4981.38184,2452.840,
3902.90161,2883.598,4981.47363,2452.840,
3902.99316,2882.598,4981.56494,2451.840,
3903.08472,2883.598,4981.65674,2450.840,
3903.17627,2883.598,4981.74805,2451.840,
3903.26782,2883.598,4981.83984,2450.840,
3903.35938,2883.598,4981.93115,2450.840,
3903.45093,2883.598,4982.02246,2449.840,
3903.54224,2883.598,4982.11426,2449.840,
3903.63379,2883.598,4982.20557,2449.840,
3903.72534,2883.598,4982.29736,2449.840,
3903.81689,2883.598,4982.38867,2449.840,
3903.90845,2883.598,4982.48047,2448.840,
3904.00000,2883.598,4982.57178,2449.840,
3904.09155,2883.598,4982.66309,2448.840,
3904.18311,2883.598,4982.75488,2448.840,
3904.27441,2883.598,4982.84619,2448.840,
3904.36597,2883.598,4982.93799,2447.840,
3904.45752,2883.598,4983.02930,2447.840,
3904.54907,2883.598,4983.12109,2447.840,
3904.64063,2883.598,4983.21240,2447.840,
3904.73218,2883.598,4983.30420,2447.840,
3904.82373,2883.598,4983.39551,2445.840,
3904.91528,2883.598,4983.48682,2446.840,
3905.00659,2883.598,4983.57861,2445.840,
3905.09814,2883.598,4983.66992,2445.840,
3905.18970,2883.598,4983.76172,2445.840,
3905.28125,2883.598,4983.85303,2444.840,
3905.37280,2883.598,4983.94482,2444.840,
3905.46436,2883.598,4984.03613,2445.840,
3905.55591,2883.598,4984.12744,2444.840,
3905.64722,2882.598,4984.21924,2444.840,
3905.73877,2883.598,4984.31055,2443.840,
3905.83032,2883.598,4984.40234,2443.840,
3905.92188,2883.598,4984.49365,2443.840,
3906.01343,2883.598,4984.58545,2443.840,
3906.10498,2883.598,4984.67676,2442.840,
3906.19653,2883.598,4984.76807,2442.840,
3906.28809,2883.598,4984.85986,2442.840,
3906.37939,2883.598,4984.95117,2441.840,
3906.47095,2883.598,4985.04297,2441.840,
3906.56250,2883.598,4985.13428,2441.840,
3906.65405,2884.598,4985.22607,2441.840,
3906.74561,2884.598,4985.31738,2441.840,
3906.83716,2884.598,4985.40918,2441.840,
3906.92871,2883.598,4985.50049,2441.840,
3907.02002,2884.598,4985.59180,2440.840,
3907.11157,2883.598,4985.68359,2440.840,
3907.20313,2884.598,4985.77490,2439.840,
3907.29468,2884.598,4985.86670,2439.840,
3907.38623,2883.598,4985.95801,2439.840,
3907.47778,2883.598,4986.04980,2439.840,
3907.56934,2883.598,4986.14111,2438.840,
3907.66089,2883.598,4986.23242,2438.840,
3907.75220,2884.598,4986.32422,2438.840,
3907.84375,2883.598,4986.41553,2437.840,
3907.93530,2883.598,4986.50732,2437.840,
3908.02686,2883.598,4986.59863,2437.840,
3908.11841,2884.598,4986.69043,2437.840,
3908.20996,2883.598,4986.78174,2436.840,
3908.30151,2883.598,4986.87305,2436.840,
3908.39307,2883.598,4986.96484,2437.840,
3908.48438,2884.598,4987.05615,2436.840,
3908.57593,2884.598,4987.14795,2436.840,
3908.66748,2883.598,4987.23926,2435.840,
3908.75903,2884.598,4987.33105,2435.840,
3908.85059,2884.598,4987.42236,2435.840,
3908.94214,2884.598,4987.51416,2434.840,
3909.03369,2884.598,4987.60547,2435.840,
3909.12500,2884.598,4987.69678,2434.840,
3909.21655,2885.598,4987.78857,2435.840,
3909.30811,2884.598,4987.87988,2433.840,
3909.39966,2884.598,4987.97168,2433.840,
3909.49121,2884.598,4988.06299,2433.840,
3909.58276,2884.598,4988.15479,2432.840,
3909.67432,2884.598,4988.24609,2433.840,
3909.76587,2884.598,4988.33740,2433.840,
3909.85718,2884.598,4988.42920,2433.840,
3909.94873,2884.598,4988.52051,2432.840,
3910.04028,2884.598,4988.61230,2432.840,
3910.13184,2884.598,4988.70361,2431.840,
3910.22339,2884.598,4988.79541,2431.840,
3910.31494,2884.598,4988.88672,2431.840,
3910.40649,2884.598,4988.97803,2431.840,
3910.49805,2884.598,4989.06982,2431.840,
3910.58936,2884.598,4989.16113,2430.840,
3910.68091,2884.598,4989.25293,2430.840,
3910.77246,2884.598,4989.34424,2429.840,
3910.86401,2884.598,4989.43604,2429.840,
3910.95557,2884.598,4989.52734,2429.840,
3911.04712,2885.598,4989.61914,2428.840,
3911.13867,2884.598,4989.71045,2429.840,
3911.22998,2885.598,4989.80176,2428.840,
3911.32153,2885.598,4989.89355,2429.840,
3911.41309,2885.598,4989.98486,2428.840,
3911.50464,2885.598,4990.07666,2428.840,
3911.59619,2885.598,4990.16797,2428.840,
3911.68774,2885.598,4990.25977,2427.840,
3911.77930,2885.598,4990.35107,2427.840,
3911.87085,2885.598,4990.44238,2427.840,
3911.96216,2885.598,4990.53418,2426.840,
3912.05371,2885.598,4990.62549,2426.840,
3912.14526,2885.598,4990.71729,2426.840,
3912.23682,2885.598,4990.80859,2425.840,
3912.32837,2884.598,4990.90039,2425.840,
3912.41992,2885.598,4990.99170,2425.840,
3912.51147,2884.598,4991.08301,2425.840,
3912.60278,2885.598,4991.17480,2425.840,
3912.69434,2884.598,4991.26611,2425.840,
3912.78589,2884.598,4991.35791,2425.840,
3912.87744,2885.598,4991.44922,2423.840,
3912.96899,2884.598,4991.54102,2423.840,
3913.06055,2885.598,4991.63232,2423.840,
3913.15210,2885.598,4991.72412,2422.840,
3913.24365,2886.598,4991.81543,2423.840,
3913.33496,2886.598,4991.90674,2422.840,
3913.42651,2887.598,4991.99854,2422.840,
3913.51807,2887.598,4992.08984,2421.840,
3913.60962,2888.598,4992.18164,2421.840,
3913.70117,2887.598,4992.27295,2421.840,
3913.79272,2888.598,4992.36475,2420.840,
3913.88428,2888.598,4992.45605,2420.840,
3913.97583,2888.598,4992.54736,2420.840,
3914.06714,2888.598,4992.63916,2420.840,
3914.15869,2888.598,4992.73047,2419.840,
3914.25024,2888.598,4992.82227,2420.840,
3914.34180,2888.598,4992.91357,2420.840,
3914.43335,2887.598,4993.00537,2419.840,
3914.52490,2887.598,4993.09668,2419.840,
3914.61646,2887.598,4993.18799,2419.840,
3914.70776,2886.598,4993.27979,2418.840,
3914.79932,2886.598,4993.37109,2418.840,
3914.89087,2886.598,4993.46289,2419.840,
3914.98242,2885.598,4993.55420,2418.840,
3915.07397,2886.598,4993.64600,2418.840,
3915.16553,2886.598,4993.73730,2418.840,
3915.25708,2885.598,4993.82910,2419.840,
3915.34863,2885.598,4993.92041,2419.840,
3915.43994,2885.598,4994.01172,2419.840,
3915.53149,2885.598,4994.10352,2419.840,
3915.62305,2885.598,4994.19482,2419.840,
3915.71460,2885.598,4994.28662,2419.840,
3915.80615,2884.598,4994.37793,2418.840,
3915.89771,2885.598,4994.46973,2417.840,
3915.98926,2884.598,4994.56104,2417.840,
3916.08081,2885.598,4994.65234,2416.840,
3916.17212,2885.598,4994.74414,2415.840,
3916.26367,2885.598,4994.83545,2415.840,
3916.35522,2885.598,4994.92725,2414.840,
3916.44678,2885.598,4995.01855,2413.840,
3916.53833,2886.598,4995.11035,2413.840,
3916.62988,2885.598,4995.20166,2413.840,
3916.72144,2885.598,4995.29297,2412.840,
3916.81274,2886.598,4995.38477,2412.840,
3916.90430,2885.598,4995.47607,2411.840,
3916.99585,2885.598,4995.56787,2411.840,
3917.08740,2886.598,4995.65918,2411.840,
3917.17896,2886.598,4995.75098,2410.840,
3917.27051,2885.598,4995.84229,2411.840,
3917.36206,2885.598,4995.93359,2410.840,
3917.45361,2885.598,4996.02539,2411.840,
3917.54492,2885.598,4996.11670,2410.840,
3917.63647,2885.598,4996.20850,2410.840,
3917.72803,2885.598,4996.29980,2410.840,
3917.81958,2885.598,4996.39160,2409.840,
3917.91113,2885.598,4996.48291,2409.840,
3918.00269,2886.598,4996.57471,2410.840,
3918.09424,2886.598,4996.66602,2408.840,
3918.18579,2885.598,4996.75732,2408.840,
3918.27710,2885.598,4996.84912,2409.840,
3918.36865,2885.598,4996.94043,2408.840,
3918.46021,2885.598,4997.03223,2408.840,
3918.55176,2885.598,4997.12354,2407.840,
3918.64331,2885.598,4997.21533,2408.840,
3918.73486,2885.598,4997.30664,2407.840,
3918.82642,2885.598,4997.39795,2407.840,
3918.91772,2885.598,4997.48975,2407.840,
3919.00928,2885.598,4997.58105,2407.840,
3919.10083,2885.598,4997.67285,2406.840,
3919.19238,2885.598,4997.76416,2405.840,
3919.28394,2886.598,4997.85596,2406.840,
3919.37549,2885.598,4997.94727,2405.840,
3919.46704,2886.598,4998.03857,2405.840,
3919.55859,2885.598,4998.13037,2404.840,
3919.64990,2886.598,4998.22168,2404.840,
3919.74146,2885.598,4998.31348,2404.840,
3919.83301,2885.598,4998.40479,2404.840,
3919.92456,2885.598,4998.49658,2404.840,
3920.01611,2885.598,4998.58789,2403.840,
3920.10767,2885.598,4998.67969,2404.840,
3920.19922,2885.598,4998.77100,2403.840,
3920.29053,2885.598,4998.86230,2403.840,
3920.38208,2885.598,4998.95410,2402.840,
3920.47363,2885.598,4999.04541,2403.840,
3920.56519,2885.598,4999.13721,2402.840,
3920.65674,2885.598,4999.22852,2402.840,
3920.74829,2885.598,4999.32031,2402.840,
3920.83984,2885.598,4999.41162,2401.840,
3920.93140,2885.598,4999.50293,2401.840,
3921.02271,2885.598,4999.59473,2401.840,
3921.11426,2885.598,4999.68604,2400.840,
3921.20581,2886.598,4999.77783,2400.840,
3921.29736,2885.598,4999.86914,2400.840,
3921.38892,2885.598,4999.96094,2399.840,
3921.48047,2885.598,5000.05225,2399.840,
3921.57202,2885.598,5000.14355,2399.840,
3921.66357,2885.598,5000.23535,2399.840,
3921.75488,2885.598,5000.32666,2399.840,
3921.84644,2885.598,5000.41846,2398.840,
3921.93799,2885.598,5000.50977,2398.840,
3922.02954,2885.598,5000.60156,2398.840,
3922.12109,2885.598,5000.69287,2397.840,
3922.21265,2885.598,5000.78467,2397.840,
3922.30420,2885.598,5000.87598,2397.840,
3922.39551,2886.598,5000.96729,2397.840,
3922.48706,2885.598,5001.05908,2396.840,
3922.57861,2885.598,5001.15039,2396.840,
3922.67017,2886.598,5001.24219,2396.840,
3922.76172,2886.598,5001.33350,2396.840,
3922.85327,2885.598,5001.42529,2396.840,
3922.94482,2886.598,5001.51660,2395.840,
3923.03638,2885.598,5001.60791,2395.840,
3923.12769,2885.598,5001.69971,2395.840,
3923.21924,2885.598,5001.79102,2394.840,
3923.31079,2885.598,5001.88281,2394.840,
3923.40234,2885.598,5001.97412,2394.840,
3923.49390,2886.598,5002.06592,2394.840,
3923.58545,2886.598,5002.15723,2393.840,
3923.67700,2885.598,5002.24854,2394.840,
3923.76855,2885.598,5002.34033,2393.840,
3923.85986,2886.598,5002.43164,2393.840,
3923.95142,2885.598,5002.52344,2392.840,
3924.04297,2885.598,5002.61475,2392.840,
3924.13452,2885.598,5002.70654,2392.840,
3924.22607,2885.598,5002.79785,2392.840,
3924.31763,2885.598,5002.88965,2391.840,
3924.40918,2886.598,5002.98096,2391.840,
3924.50049,2886.598,5003.07227,2391.840,
3924.59204,2886.598,5003.16406,2391.840,
3924.68359,2885.598,5003.25537,2390.840,
3924.77515,2885.598,5003.34717,2390.840,
3924.86670,2885.598,5003.43848,2389.840,
3924.95825,2885.598,5003.53027,2389.840,
3925.04980,2885.598,5003.62158,2389.840,
3925.14136,2885.598,5003.71289,2389.840,
3925.23267,2886.598,5003.80469,2389.840,
3925.32422,2886.598,5003.89600,2388.840,
3925.41577,2885.598,5003.98779,2388.840,
3925.50732,2886.598,5004.07910,2388.840,
3925.59888,2886.598,5004.17090,2388.840,
3925.69043,2885.598,5004.26221,2387.840,
3925.78198,2885.598,5004.35352,2387.840,
3925.87329,2886.598,5004.44531,2387.840,
3925.96484,2886.598,5004.53662,2387.840,
3926.05640,2885.598,5004.62842,2387.840,
3926.14795,2885.598,5004.71973,2386.840,
3926.23950,2886.598,5004.81152,2386.840,
3926.33105,2885.598,5004.90283,2386.840,
3926.42261,2885.598,5004.99463,2385.840,
3926.51416,2885.598,5005.08594,2385.840,
3926.60547,2886.598,5005.17725,2385.840,
3926.69702,2886.598,5005.26904,2385.840,
3926.78857,2886.598,5005.36035,2384.840,
3926.88013,2885.598,5005.45215,2384.840,
3926.97168,2885.598,5005.54346,2384.840,
3927.06323,2885.598,5005.63525,2383.840,
3927.15479,2885.598,5005.72656,2383.840,
3927.24634,2885.598,5005.81787,2383.840,
3927.33765,2886.598,5005.90967,2382.840,
3927.42920,2886.598,5006.00098,2383.840,
3927.52075,2886.598,5006.09277,2382.840,
3927.61230,2885.598,5006.18408,2382.840,
3927.70386,2885.598,5006.27588,2381.840,
3927.79541,2886.598,5006.36719,2381.840,
3927.88696,2885.598,5006.45850,2381.840,
3927.97827,2885.598,5006.55029,2381.840,
3928.06982,2886.598,5006.64160,2381.840,
3928.16138,2885.598,5006.73340,2380.840,
3928.25293,2886.598,5006.82471,2380.840,
3928.34448,2886.598,5006.91650,2379.840,
3928.43604,2885.598,5007.00781,2380.840,
3928.52759,2886.598,5007.09912,2379.840,
3928.61914,2885.598,5007.19092,2379.840,
3928.71045,2885.598,5007.28223,2379.840,
3928.80200,2885.598,5007.37402,2378.840,
3928.89355,2885.598,5007.46533,2379.840,
3928.98511,2885.598,5007.55713,2377.840,
3929.07666,2885.598,5007.64844,2377.840,
3929.16821,2885.598,5007.74023,2377.840,
3929.25977,2884.598,5007.83154,2377.840,
3929.35132,2884.598,5007.92285,2377.840,
3929.44263,2884.598,5008.01465,2376.840,
3929.53418,2883.598,5008.10596,2376.840,
3929.62573,2883.598,5008.19775,2376.840,
3929.71729,2884.598,5008.28906,2376.840,
3929.80884,2884.598,5008.38086,2375.840,
3929.90039,2884.598,5008.47217,2375.840,
3929.99194,2884.598,5008.56348,2375.840,
3930.08325,2884.598,5008.65527,2374.840,
3930.17480,2884.598,5008.74658,2374.840,
3930.26636,2884.598,5008.83838,2374.840,
3930.35791,2884.598,5008.92969,2374.840,
3930.44946,2884.598,5009.02148,2373.840,
3930.54102,2885.598,5009.11279,2373.840,
3930.63257,2884.598,5009.20410,2373.840,
3930.72412,2885.598,5009.29590,2373.840,
3930.81543,2885.598,5009.38721,2372.840,
3930.90698,2885.598,5009.47900,2372.840,
3930.99854,2885.598,5009.57031,2372.840,
3931.09009,2885.598,5009.66211,2372.840,
3931.18164,2886.598,5009.75342,2371.840,
3931.27319,2885.598,5009.84521,2371.840,
3931.36475,2885.598,5009.93652,2371.840,
3931.45605,2884.598,5010.02783,2371.840,
3931.54761,2885.598,5010.11963,2370.840,
3931.63916,2884.598,5010.21094,2371.840,
3931.73071,2883.598,5010.30273,2370.840,
3931.82227,2882.598,5010.39404,2371.840,
3931.91382,2882.598,5010.48584,2370.840,
3932.00537,2881.598,5010.57715,2370.840,
3932.09692,2882.598,5010.66846,2370.840,
3932.18823,2882.598,5010.76025,2369.840,
3932.27979,2882.598,5010.85156,2369.840,
3932.37134,2882.598,5010.94336,2369.840,
3932.46289,2883.598,5011.03467,2368.840,
3932.55444,2883.598,5011.12646,2368.840,
3932.64600,2884.598,5011.21777,2368.840,
3932.73755,2883.598,5011.30908,2367.840,
3932.82910,2884.598,5011.40088,2367.840,
3932.92041,2884.598,5011.49219,2367.840,
3933.01196,2885.598,5011.58398,2366.840,
3933.10352,2885.598,5011.67529,2365.840,
3933.19507,2885.598,5011.76709,2365.840,
3933.28662,2885.598,5011.85840,2364.840,
3933.37817,2885.598,5011.95020,2362.840,
3933.46973,2885.598,5012.04150,2361.840,
3933.56104,2885.598,5012.13281,2361.840,
3933.65259,2885.598,5012.22461,2361.840,
3933.74414,2885.598,5012.31592,2360.840,
3933.83569,2885.598,5012.40771,2360.840,
3933.92725,2885.598,5012.49902,2360.840,
3934.01880,2885.598,5012.59082,2360.840,
3934.11035,2886.598,5012.68213,2360.840,
3934.20190,2885.598,5012.77344,2360.840,
3934.29321,2886.598,5012.86523,2360.840,
3934.38477,2885.598,5012.95654,2360.840,
3934.47632,2886.598,5013.04834,2360.840,
3934.56787,2886.598,5013.13965,2361.840,
3934.65942,2885.598,5013.23145,2360.840,
3934.75098,2886.598,5013.32275,2360.840,
3934.84253,2886.598,5013.41406,2361.840,
3934.93408,2886.598,5013.50586,2360.840,
3935.02539,2886.598,5013.59717,2360.840,
3935.11694,2885.598,5013.68896,2360.840,
3935.20850,2885.598,5013.78027,2359.840,
3935.30005,2885.598,5013.87207,2359.840,
3935.39160,2885.598,5013.96338,2359.840,
3935.48315,2885.598,5014.05518,2359.840,
3935.57471,2886.598,5014.14648,2358.840,
3935.66602,2886.598,5014.23779,2358.840,
3935.75757,2885.598,5014.32959,2358.840,
3935.84912,2886.598,5014.42090,2358.840,
3935.94067,2885.598,5014.51270,2357.840,
3936.03223,2885.598,5014.60400,2357.840,
3936.12378,2885.598,5014.69580,2356.840,
3936.21533,2885.598,5014.78711,2357.840,
3936.30688,2885.598,5014.87842,2357.840,
3936.39819,2885.598,5014.97021,2356.840,
3936.48975,2885.598,5015.06152,2356.840,
3936.58130,2885.598,5015.15332,2356.840,
3936.67285,2885.598,5015.24463,2355.840,
3936.76440,2885.598,5015.33643,2355.840,
3936.85596,2885.598,5015.42773,2355.840,
3936.94751,2886.598,5015.51904,2355.840,
3937.03906,2885.598,5015.61084,2354.840,
3937.13037,2885.598,5015.70215,2354.840,
3937.22192,2885.598,5015.79395,2354.840,
3937.31348,2885.598,5015.88525,2353.840,
3937.40503,2885.598,5015.97705,2353.840,
3937.49658,2885.598,5016.06836,2352.840,
3937.58813,2885.598,5016.16016,2352.840,
3937.67969,2885.598,5016.25146,2353.840,
3937.77100,2885.598,5016.34277,2352.840,
3937.86255,2885.598,5016.43457,2352.840,
3937.95410,2884.598,5016.52588,2351.840,
3938.04565,2885.598,5016.61768,2351.840,
3938.13721,2885.598,5016.70898,2351.840,
3938.22876,2885.598,5016.80078,2351.840,
3938.32031,2885.598,5016.89209,2351.840,
3938.41187,2885.598,5016.98340,2350.840,
3938.50317,2886.598,5017.07520,2349.840,
3938.59473,2885.598,5017.16650,2350.840,
3938.68628,2885.598,5017.25830,2349.840,
3938.77783,2885.598,5017.34961,2349.840,
3938.86938,2885.598,5017.44141,2349.840,
3938.96094,2885.598,5017.53271,2348.840,
3939.05249,2885.598,5017.62402,2348.840,
3939.14380,2885.598,5017.71582,2348.840,
3939.23535,2885.598,5017.80713,2348.840,
3939.32690,2885.598,5017.89893,2347.840,
3939.41846,2885.598,5017.99023,2347.840,
3939.51001,2884.598,5018.08203,2347.840,
3939.60156,2885.598,5018.17334,2346.840,
3939.69312,2885.598,5018.26514,2346.840,
3939.78467,2885.598,5018.35645,2346.840,
3939.87598,2885.598,5018.44775,2346.840,
3939.96753,2885.598,5018.53955,2345.840,
3940.05908,2885.598,5018.63086,2345.840,
3940.15063,2885.598,5018.72266,2345.840,
3940.24219,2885.598,5018.81396,2345.840,
3940.33374,2885.598,5018.90576,2344.840,
3940.42529,2885.598,5018.99707,2344.840,
3940.51685,2884.598,5019.08838,2344.840,
3940.60815,2885.598,5019.18018,2343.840,
3940.69971,2885.598,5019.27148,2343.840,
3940.79126,2884.598,5019.36328,2343.840,
3940.88281,2884.598,5019.45459,2342.840,
3940.97437,2884.598,5019.54639,2342.840,
3941.06592,2884.598,5019.63770,2342.840,
3941.15747,2884.598,5019.72900,2342.840,
3941.24878,2884.598,5019.82080,2342.840,
3941.34033,2884.598,5019.91211,2341.840,
3941.43188,2885.598,5020.00391,2341.840,
3941.52344,2885.598,5020.09521,2341.840,
3941.61499,2885.598,5020.18701,2340.840,
3941.70654,2884.598,5020.27832,2340.840,
3941.79810,2884.598,5020.36963,2340.840,
3941.88965,2885.598,5020.46143,2340.840,
3941.98096,2885.598,5020.55273,2339.840,
3942.07251,2885.598,5020.64453,2339.840,
3942.16406,2885.598,5020.73584,2339.840,
3942.25562,2885.598,5020.82764,2339.840,
3942.34717,2885.598,5020.91895,2338.840,
3942.43872,2884.598,5021.01074,2338.840,
3942.53027,2885.598,5021.10205,2339.840,
3942.62183,2884.598,5021.19336,2338.840,
3942.71313,2884.598,5021.28516,2338.840,
3942.80469,2884.598,5021.37646,2337.840,
3942.89624,2885.598,5021.46826,2337.840,
3942.98779,2884.598,5021.55957,2336.840,
3943.07935,2885.598,5021.65137,2336.840,
3943.17090,2884.598,5021.74268,2335.840,
3943.26245,2884.598,5021.83398,2335.840,
3943.35376,2885.598,5021.92578,2335.840,
3943.44531,2885.598,5022.01709,2335.840,
3943.53687,2885.598,5022.10889,2335.840,
3943.62842,2885.598,5022.20020,2334.840,
3943.71997,2884.598,5022.29199,2334.840,
3943.81152,2885.598,5022.38330,2333.840,
3943.90308,2885.598,5022.47461,2333.840,
3943.99463,2884.598,5022.56641,2333.840,
3944.08594,2884.598,5022.65771,2333.840,
3944.17749,2884.598,5022.74951,2333.840,
3944.26904,2885.598,5022.84082,2333.840,
3944.36060,2885.598,5022.93262,2332.840,
3944.45215,2884.598,5023.02393,2332.840,
3944.54370,2884.598,5023.11572,2332.840,
3944.63525,2884.598,5023.20703,2331.840,
3944.72656,2884.598,5023.29834,2331.840,
3944.81812,2884.598,5023.39014,2331.840,
3944.90967,2884.598,5023.48145,2331.840,
3945.00122,2884.598,5023.57324,2332.840,
3945.09277,2884.598,5023.66455,2330.840,
3945.18433,2884.598,5023.75635,2331.840,
3945.27588,2884.598,5023.84766,2330.840,
3945.36743,2884.598,5023.93896,2329.840,
3945.45874,2884.598,5024.03076,2329.840,
3945.55029,2884.598,5024.12207,2329.840,
3945.64185,2884.598,5024.21387,2328.840,
3945.73340,2884.598,5024.30518,2329.840,
3945.82495,2885.598,5024.39697,2327.840,
3945.91650,2884.598,5024.48828,2327.840,
3946.00806,2884.598,5024.57959,2327.840,
3946.09961,2885.598,5024.67139,2327.840,
3946.19092,2884.598,5024.76270,2327.840,
3946.28247,2884.598,5024.85449,2326.840,
3946.37402,2885.598,5024.94580,2326.840,
3946.46558,2884.598,5025.03760,2327.840,
3946.55713,2884.598,5025.12891,2326.840,
3946.64868,2884.598,5025.22070,2325.840,
3946.74023,2883.598,5025.31201,2325.840,
3946.83154,2884.598,5025.40332,2324.840,
3946.92310,2884.598,5025.49512,2324.840,
3947.01465,2884.598,5025.58643,2324.840,
3947.10620,2884.598,5025.67822,2324.840,
3947.19775,2883.598,5025.76953,2323.840,
3947.28931,2884.598,5025.86133,2323.840,
3947.38086,2884.598,5025.95264,2323.840,
3947.47241,2884.598,5026.04395,2323.840,
3947.56372,2884.598,5026.13574,2322.840,
3947.65527,2884.598,5026.22705,2322.840,
3947.74683,2885.598,5026.31885,2322.840,
3947.83838,2885.598,5026.41016,2322.840,
3947.92993,2885.598,5026.50195,2321.840,
3948.02148,2885.598,5026.59326,2321.840,
3948.11304,2885.598,5026.68457,2321.840,
3948.20459,2885.598,5026.77637,2321.840,
3948.29590,2885.598,5026.86768,2320.840,
3948.38745,2885.598,5026.95947,2320.840,
3948.47900,2885.598,5027.05078,2319.840,
3948.57056,2885.598,5027.14258,2320.840,
3948.66211,2885.598,5027.23389,2319.840,
3948.75366,2885.598,5027.32568,2319.840,
3948.84521,2884.598,5027.41699,2319.840,
3948.93652,2884.598,5027.50830,2319.840,
3949.02808,2884.598,5027.60010,2319.840,
3949.11963,2884.598,5027.69141,2319.840,
3949.21118,2884.598,5027.78320,2319.840,
3949.30273,2884.598,5027.87451,2319.840,
3949.39429,2883.598,5027.96631,2318.840,
3949.48584,2883.598,5028.05762,2318.840,
3949.57739,2883.598,5028.14893,2318.840,
3949.66870,2883.598,5028.24072,2318.840,
3949.76025,2882.598,5028.33203,2317.840,
3949.85181,2882.598,5028.42383,2317.840,
3949.94336,2881.598,5028.51514,2316.840,
3950.03491,2880.598,5028.60693,2316.840,
3950.12646,2880.598,5028.69824,2316.840,
3950.21802,2881.598,5028.78955,2315.840,
3950.30933,2880.598,5028.88135,2315.840,
3950.40088,2880.598,5028.97266,2314.840,
3950.49243,2880.598,5029.06445,2314.840,
3950.58398,2880.598,5029.15576,2313.840,
3950.67554,2881.598,5029.24756,2313.840,
3950.76709,2881.598,5029.33887,2312.840,
3950.85864,2881.598,5029.43066,2313.840,
3950.95020,2881.598,5029.52197,2312.840,
3951.04150,2882.598,5029.61328,2311.840,
3951.13306,2882.598,5029.70508,2312.840,
3951.22461,2882.598,5029.79639,2311.840,
3951.31616,2882.598,5029.88818,2311.840,
3951.40771,2882.598,5029.97949,2311.840,
3951.49927,2882.598,5030.07129,2311.840,
3951.59082,2882.598,5030.16260,2311.840,
3951.68237,2883.598,5030.25391,2311.840,
3951.77368,2882.598,5030.34570,2311.840,
3951.86523,2882.598,5030.43701,2310.840,
3951.95679,2882.598,5030.52881,2310.840,
3952.04834,2882.598,5030.62012,2311.840,
3952.13989,2882.598,5030.71191,2310.840,
3952.23145,2882.598,5030.80322,2310.840,
3952.32300,2882.598,5030.89453,2310.840,
3952.41431,2882.598,5030.98633,2309.840,
3952.50586,2882.598,5031.07764,2309.840,
3952.59741,2882.598,5031.16943,2309.840,
3952.68896,2882.598,5031.26074,2308.840,
3952.78052,2882.598,5031.35254,2308.840,
3952.87207,2882.598,5031.44385,2307.840,
3952.96362,2882.598,5031.53516,2308.840,
3953.05518,2882.598,5031.62695,2306.840,
3953.14648,2883.598,5031.71826,2306.840,
3953.23804,2882.598,5031.81006,2306.840,
3953.32959,2882.598,5031.90137,2305.840,
3953.42114,2882.598,5031.99316,2304.840,
3953.51270,2882.598,5032.08447,2305.840,
3953.60425,2882.598,5032.17627,2304.840,
3953.69580,2882.598,5032.26758,2303.840,
3953.78735,2882.598,5032.35889,2304.840,
3953.87866,2882.598,5032.45068,2303.840,
3953.97021,2882.598,5032.54199,2303.840,
3954.06177,2882.598,5032.63379,2303.840,
3954.15332,2882.598,5032.72510,2303.840,
3954.24487,2882.598,5032.81689,2302.840,
3954.33643,2882.598,5032.90820,2302.840,
3954.42798,2881.598,5032.99951,2302.840,
3954.51929,2881.598,5033.09131,2301.840,
3954.61084,2882.598,5033.18262,2301.840,
3954.70239,2881.598,5033.27441,2301.840,
3954.79395,2881.598,5033.36572,2300.840,
3954.88550,2881.598,5033.45752,2299.840,
3954.97705,2881.598,5033.54883,2299.840,
3955.06860,2881.598,5033.64014,2299.840,
3955.16016,2881.598,5033.73193,2299.840,
3955.25146,2882.598,5033.82324,2299.840,
3955.34302,2881.598,5033.91504,2298.840,
3955.43457,2881.598,5034.00635,2298.840,
3955.52612,2881.598,5034.09814,2298.840,
3955.61768,2881.598,5034.18945,2298.840,
3955.70923,2881.598,5034.28125,2297.840,
3955.80078,2881.598,5034.37256,2297.840,
3955.89233,2881.598,5034.46387,2297.840,
3955.98364,2881.598,5034.55566,2296.840,
3956.07520,2882.598,5034.64697,2296.840,
3956.16675,2881.598,5034.73877,2296.840,
3956.25830,2881.598,5034.83008,2295.840,
3956.34985,2881.598,5034.92188,2295.840,
3956.44141,2881.598,5035.01318,2295.840,
3956.53296,2881.598,5035.10449,2295.840,
3956.62427,2881.598,5035.19629,2295.840,
3956.71582,2881.598,5035.28760,2295.840,
3956.80737,2881.598,5035.37939,2294.840,
3956.89893,2880.598,5035.47070,2294.840,
3956.99048,2881.598,5035.56250,2293.840,
3957.08203,2881.598,5035.65381,2293.840,
3957.17358,2881.598,5035.74512,2293.840,
3957.26514,2880.598,5035.83691,2292.840,
3957.35645,2881.598,5035.92822,2292.840,
3957.44800,2880.598,5036.02002,2292.840,
3957.53955,2881.598,5036.11133,2291.840,
3957.63110,2881.598,5036.20313,2292.840,
3957.72266,2880.598,5036.29443,2291.840,
3957.81421,2880.598,5036.38623,2290.840,
3957.90576,2880.598,5036.47754,2290.840,
3957.99707,2880.598,5036.56885,2290.840,
3958.08862,2881.598,5036.66064,2290.840,
3958.18018,2881.598,5036.75195,2290.840,
3958.27173,2881.598,5036.84375,2289.840,
3958.36328,2880.598,5036.93506,2289.840,
3958.45483,2880.598,5037.02686,2289.840,
3958.54639,2881.598,5037.11816,2288.840,
3958.63794,2880.598,5037.20947,2288.840,
3958.72925,2880.598,5037.30127,2288.840,
3958.82080,2881.598,5037.39258,2288.840,
3958.91235,2880.598,5037.48438,2287.840,
3959.00391,2881.598,5037.57568,2287.840,
3959.09546,2880.598,5037.66748,2287.840,
3959.18701,2880.598,5037.75879,2286.840,
3959.27856,2880.598,5037.85010,2286.840,
3959.37012,2880.598,5037.94189,2286.840,
3959.46143,2881.598,5038.03320,2285.840,
3959.55298,2880.598,5038.12500,2285.840,
3959.64453,2880.598,5038.21631,2286.840,
3959.73608,2880.598,5038.30811,2284.840,
3959.82764,2880.598,5038.39941,2284.840,
3959.91919,2880.598,5038.49121,2284.840,
3960.01074,2880.598,5038.58252,2284.840,
3960.10205,2880.598,5038.67383,2284.840,
3960.19360,2880.598,5038.76563,2283.840,
3960.28516,2880.598,5038.85693,2283.840,
3960.37671,2880.598,5038.94873,2283.840,
3960.46826,2880.598,5039.04004,2283.840,
3960.55981,2880.598,5039.13184,2282.840,
3960.65137,2879.598,5039.22314,2282.840,
3960.74292,2879.598,5039.31445,2282.840,
3960.83423,2879.598,5039.40625,2281.840,
3960.92578,2880.598,5039.49756,2281.840,
3961.01733,2880.598,5039.58936,2281.840,
3961.10889,2880.598,5039.68066,2281.840,
3961.20044,2879.598,5039.77246,2280.840,
3961.29199,2879.598,5039.86377,2281.840,
3961.38354,2879.598,5039.95508,2280.840,
3961.47510,2879.598,5040.04688,2279.840,
3961.56641,2879.598,5040.13818,2279.840,
3961.65796,2879.598,5040.22998,2279.840,
3961.74951,2879.598,5040.32129,2279.840,
3961.84106,2879.598,5040.41309,2279.840,
3961.93262,2880.598,5040.50439,2278.840,
3962.02417,2879.598,5040.59619,2278.840,
3962.11572,2879.598,5040.68750,2277.840,
3962.20703,2879.598,5040.77881,2277.840,
3962.29858,2879.598,5040.87061,2277.840,
3962.39014,2879.598,5040.96191,2277.840,
3962.48169,2879.598,5041.05371,2277.840,
3962.57324,2879.598,5041.14502,2276.840,
3962.66479,2878.598,5041.23682,2276.840,
3962.75635,2878.598,5041.32813,2275.840,
3962.84790,2879.598,5041.41943,2275.840,
3962.93921,2879.598,5041.51123,2274.840,
3963.03076,2878.598,5041.60254,2274.840,
3963.12231,2878.598,5041.69434,2274.840,
3963.21387,2879.598,5041.78564,2274.840,
3963.30542,2878.598,5041.87744,2274.840,
3963.39697,2879.598,5041.96875,2273.840,
3963.48853,2879.598,5042.06006,2273.840,
3963.57983,2879.598,5042.15186,2272.840,
3963.67139,2879.598,5042.24316,2273.840,
3963.76294,2878.598,5042.33496,2272.840,
3963.85449,2878.598,5042.42627,2271.840,
3963.94604,2878.598,5042.51807,2272.840,
3964.03760,2879.598,5042.60938,2272.840,
3964.12915,2879.598,5042.70117,2271.840,
3964.22070,2878.598,5042.79248,2271.840,
3964.31201,2878.598,5042.88379,2271.840,
3964.40356,2878.598,5042.97559,2270.840,
3964.49512,2878.598,5043.06689,2270.840,
3964.58667,2878.598,5043.15869,2270.840,
3964.67822,2878.598,5043.25000,2270.840,
3964.76978,2878.598,5043.34180,2269.840,
3964.86133,2879.598,5043.43311,2269.840,
3964.95288,2878.598,5043.52441,2269.840,
3965.04419,2878.598,5043.61621,2268.840,
3965.13574,2878.598,5043.70752,2268.840,
3965.22729,2878.598,5043.79932,2268.840,
3965.31885,2878.598,5043.89063,2267.840,
3965.41040,2878.598,5043.98242,2268.840,
3965.50195,2877.598,5044.07373,2268.840,
3965.59351,2878.598,5044.16504,2267.840,
3965.68481,2878.598,5044.25684,2266.840,
3965.77637,2877.598,5044.34814,2267.840,
3965.86792,2877.598,5044.43994,2266.840,
3965.95947,2877.598,5044.53125,2265.840,
3966.05103,2877.598,5044.62305,2265.840,
3966.14258,2877.598,5044.71436,2265.840,
3966.23413,2876.598,5044.80566,2265.840,
3966.32568,2877.598,5044.89746,2264.840,
3966.41699,2876.598,5044.98877,2264.840,
3966.50854,2876.598,5045.08057,2264.840,
3966.60010,2875.598,5045.17188,2263.840,
3966.69165,2875.598,5045.26367,2263.840,
3966.78320,2875.598,5045.35498,2262.840,
3966.87476,2875.598,5045.44678,2262.840,
3966.96631,2875.598,5045.53809,2262.840,
3967.05786,2875.598,5045.62939,2261.840,
3967.14917,2875.598,5045.72119,2259.840,
3967.24072,2875.598,5045.81250,2260.840,
3967.33228,2876.598,5045.90430,2259.840,
3967.42383,2876.598,5045.99561,2259.840,
3967.51538,2876.598,5046.08740,2259.840,
3967.60693,2876.598,5046.17871,2259.840,
3967.69849,2876.598,5046.27002,2259.840,
3967.78979,2877.598,5046.36182,2258.840,
3967.88135,2877.598,5046.45313,2258.840,
3967.97290,2877.598,5046.54492,2258.840,
3968.06445,2877.598,5046.63623,2258.840,
3968.15601,2877.598,5046.72803,2258.840,
3968.24756,2877.598,5046.81934,2257.840,
3968.33911,2878.598,5046.91064,2258.840,
3968.43066,2878.598,5047.00244,2258.840,
3968.52197,2878.598,5047.09375,2257.840,
3968.61353,2879.598,5047.18555,2257.840,
3968.70508,2879.598,5047.27686,2257.840,
3968.79663,2879.598,5047.36865,2257.840,
3968.88818,2879.598,5047.45996,2257.840,
3968.97974,2879.598,5047.55176,2257.840,
3969.07129,2879.598,5047.64307,2258.840,
3969.16260,2879.598,5047.73438,2257.840,
3969.25415,2879.598,5047.82617,2257.840,
3969.34570,2878.598,5047.91748,2257.840,
3969.43726,2877.598,5048.00928,2256.840,
3969.52881,2877.598,5048.10059,2256.840,
3969.62036,2877.598,5048.19238,2255.840,
3969.71191,2877.598,5048.28369,2254.840,
3969.80347,2877.598,5048.37500,2254.840,
3969.89478,2876.598,5048.46680,2254.840,
3969.98633,2877.598,5048.55811,2253.840,
3970.07788,2876.598,5048.64990,2252.840,
3970.16943,2876.598,5048.74121,2252.840,
3970.26099,2876.598,5048.83301,2251.840,
3970.35254,2876.598,5048.92432,2251.840,
3970.44409,2875.598,5049.01563,2251.840,
3970.53564,2875.598,5049.10742,2251.840,
3970.62695,2875.598,5049.19873,2250.840,
3970.71851,2876.598,5049.29053,2250.840,
3970.81006,2876.598,5049.38184,2249.840,
3970.90161,2875.598,5049.47363,2249.840,
3970.99316,2876.598,5049.56494,2249.840,
3971.08472,2876.598,5049.65674,2249.840,
3971.17627,2875.598,5049.74805,2249.840,
3971.26758,2876.598,5049.83936,2248.840,
3971.35913,2876.598,5049.93115,2249.840,
3971.45068,2875.598,5050.02246,2248.840,
3971.54224,2875.598,5050.11426,2248.840,
3971.63379,2875.598,5050.20557,2248.840,
3971.72534,2875.598,5050.29736,2247.840,
3971.81689,2876.598,5050.38867,2247.840,
3971.90845,2875.598,5050.47998,2247.840,
3971.99976,2875.598,5050.57178,2246.840,
3972.09131,2875.598,5050.66309,2246.840,
3972.18286,2875.598,5050.75488,2245.840,
3972.27441,2875.598,5050.84619,2245.840,
3972.36597,2875.598,5050.93799,2245.840,
3972.45752,2875.598,5051.02930,2245.840,
3972.54907,2875.598,5051.12061,2245.840,
3972.64063,2875.598,5051.21240,2244.840,
3972.73193,2875.598,5051.30371,2244.840,
3972.82349,2875.598,5051.39551,2244.840,
3972.91504,2874.598,5051.48682,2243.840,
3973.00659,2875.598,5051.57861,2243.840,
3973.09814,2875.598,5051.66992,2244.840,
3973.18970,2875.598,5051.76172,2242.840,
3973.28125,2874.598,5051.85303,2243.840,
3973.37256,2874.598,5051.94434,2241.840,
3973.46411,2874.598,5052.03613,2242.840,
3973.55566,2874.598,5052.12744,2242.840,
3973.64722,2875.598,5052.21924,2241.840,
3973.73877,2874.598,5052.31055,2240.840,
3973.83032,2874.598,5052.40234,2241.840,
3973.92188,2874.598,5052.49365,2240.840,
3974.01343,2874.598,5052.58496,2240.840,
3974.10474,2874.598,5052.67676,2240.840,
3974.19629,2875.598,5052.76807,2239.840,
3974.28784,2875.598,5052.85986,2240.840,
3974.37939,2874.598,5052.95117,2239.840,
3974.47095,2874.598,5053.04297,2239.840,
3974.56250,2874.598,5053.13428,2239.840,
3974.65405,2874.598,5053.22559,2238.840,
3974.74536,2874.598,5053.31738,2238.840,
3974.83691,2874.598,5053.40869,2238.840,
3974.92847,2874.598,5053.50049,2237.840,
3975.02002,2874.598,5053.59180,2237.840,
3975.11157,2874.598,5053.68359,2237.840,
3975.20313,2874.598,5053.77490,2236.840,
3975.29468,2874.598,5053.86670,2236.840,
3975.38623,2874.598,5053.95801,2236.840,
3975.47754,2874.598,5054.04932,2235.840,
3975.56909,2873.598,5054.14111,2235.840,
3975.66064,2874.598,5054.23242,2235.840,
3975.75220,2874.598,5054.32422,2235.840,
3975.84375,2873.598,5054.41553,2235.840,
3975.93530,2873.598,5054.50732,2234.840,
3976.02686,2873.598,5054.59863,2234.840,
3976.11841,2873.598,5054.68994,2234.840,
3976.20972,2873.598,5054.78174,2234.840,
3976.30127,2874.598,5054.87305,2233.840,
3976.39282,2873.598,5054.96484,2232.840,
3976.48438,2873.598,5055.05615,2233.840,
3976.57593,2874.598,5055.14795,2232.840,
3976.66748,2873.598,5055.23926,2231.840,
3976.75903,2873.598,5055.33057,2232.840,
3976.85034,2873.598,5055.42236,2231.840,
3976.94189,2874.598,5055.51367,2231.840,
3977.03345,2873.598,5055.60547,2230.840,
3977.12500,2873.598,5055.69678,2230.840,
3977.21655,2873.598,5055.78857,2230.840,
3977.30811,2872.598,5055.87988,2230.840,
3977.39966,2873.598,5055.97168,2230.840,
3977.49121,2873.598,5056.06299,2229.840,
3977.58252,2873.598,5056.15430,2229.840,
3977.67407,2872.598,5056.24609,2228.840,
3977.76563,2873.598,5056.33740,2228.840,
3977.85718,2872.598,5056.42920,2228.840,
3977.94873,2872.598,5056.52051,2228.840,
3978.04028,2873.598,5056.61230,2227.840,
3978.13184,2872.598,5056.70361,2227.840,
3978.22339,2872.598,5056.79492,2226.840,
3978.31470,2872.598,5056.88672,2227.840,
3978.40625,2872.598,5056.97803,2226.840,
3978.49780,2871.598,5057.06982,2226.840,
3978.58936,2871.598,5057.16113,2226.840,
3978.68091,2872.598,5057.25293,2226.840,
3978.77246,2872.598,5057.34424,2225.840,
3978.86401,2872.598,5057.43555,2225.840,
3978.95532,2871.598,5057.52734,2225.840,
3979.04688,2872.598,5057.61865,2224.840,
3979.13843,2871.598,5057.71045,2224.840,
3979.22998,2871.598,5057.80176,2224.840,
3979.32153,2871.598,5057.89355,2223.840,
3979.41309,2871.598,5057.98486,2223.840,
3979.50464,2872.598,5058.07617,2223.840,
3979.59619,2871.598,5058.16797,2222.840,
3979.68750,2871.598,5058.25928,2222.840,
3979.77905,2872.598,5058.35107,2222.840,
3979.87061,2872.598,5058.44238,2222.840,
3979.96216,2872.598,5058.53418,2221.840,
3980.05371,2871.598,5058.62549,2221.840,
3980.14526,2871.598,5058.71729,2221.840,
3980.23682,2871.598,5058.80859,2220.840,
3980.32837,2871.598,5058.89990,2220.840,
3980.41968,2871.598,5058.99170,2220.840,
3980.51123,2871.598,5059.08301,2220.840,
3980.60278,2871.598,5059.17480,2219.840,
3980.69434,2871.598,5059.26611,2219.840,
3980.78589,2871.598,5059.35791,2218.840,
3980.87744,2870.598,5059.44922,2219.840,
3980.96899,2871.598,5059.54053,2218.840,
3981.06030,2871.598,5059.63232,2217.840,
3981.15186,2870.598,5059.72363,2217.840,
3981.24341,2871.598,5059.81543,2217.840,
3981.33496,2871.598,5059.90674,2217.840,
3981.42651,2871.598,5059.99854,2217.840,
3981.51807,2870.598,5060.08984,2216.840,
3981.60962,2871.598,5060.18115,2216.840,
3981.70117,2870.598,5060.27295,2216.840,
3981.79248,2870.598,5060.36426,2216.840,
3981.88403,2870.598,5060.45605,2215.840,
3981.97559,2870.598,5060.54736,2215.840,
3982.06714,2871.598,5060.63916,2215.840,
3982.15869,2870.598,5060.73047,2214.840,
3982.25024,2870.598,5060.82227,2214.840,
3982.34180,2870.598,5060.91357,2214.840,
3982.43311,2870.598,5061.00488,2214.840,
3982.52466,2870.598,5061.09668,2213.840,
3982.61621,2870.598,5061.18799,2213.840,
3982.70776,2870.598,5061.27979,2213.840,
3982.79932,2870.598,5061.37109,2212.840,
3982.89087,2870.598,5061.46289,2212.840,
3982.98242,2870.598,5061.55420,2211.840,
3983.07397,2870.598,5061.64551,2212.840,
3983.16528,2870.598,5061.73730,2211.840,
3983.25684,2869.598,5061.82861,2211.840,
3983.34839,2870.598,5061.92041,2211.840,
3983.43994,2870.598,5062.01172,2211.840,
3983.53149,2869.598,5062.10352,2210.840,
3983.62305,2869.598,5062.19482,2210.840,
3983.71460,2870.598,5062.28613,2209.840,
3983.80615,2869.598,5062.37793,2209.840,
3983.89746,2870.598,5062.46924,2209.840,
3983.98901,2869.598,5062.56104,2208.840,
3984.08057,2869.598,5062.65234,2208.840,
3984.17212,2869.598,5062.74414,2207.840,
3984.26367,2869.598,5062.83545,2207.840,
3984.35522,2869.598,5062.92725,2206.840,
3984.44678,2869.598,5063.01855,2205.840,
3984.53809,2869.598,5063.10986,2205.840,
3984.62964,2870.598,5063.20166,2204.840,
3984.72119,2870.598,5063.29297,2203.840,
3984.81274,2871.598,5063.38477,2203.840,
3984.90430,2871.598,5063.47607,2202.840,
3984.99585,2871.598,5063.56787,2202.840,
3985.08740,2871.598,5063.65918,2202.840,
3985.17896,2871.598,5063.75049,2202.840,
3985.27026,2871.598,5063.84229,2202.840,
3985.36182,2871.598,5063.93359,2202.840,
3985.45337,2871.598,5064.02539,2202.840,
3985.54492,2871.598,5064.11670,2202.840,
3985.63647,2870.598,5064.20850,2202.840,
3985.72803,2870.598,5064.29980,2202.840,
3985.81958,2870.598,5064.39111,2202.840,
3985.91113,2869.598,5064.48291,2201.840,
3986.00244,2869.598,5064.57422,2202.840,
3986.09399,2870.598,5064.66602,2201.840,
3986.18555,2869.598,5064.75732,2201.840,
3986.27710,2869.598,5064.84912,2201.840,
3986.36865,2868.598,5064.94043,2201.840,
3986.46021,2868.598,5065.03223,2200.840,
3986.55176,2868.598,5065.12354,2200.840,
3986.64307,2868.598,5065.21484,2200.840,
3986.73462,2867.598,5065.30664,2201.840,
3986.82617,2868.598,5065.39795,2200.840,
3986.91772,2868.598,5065.48975,2200.840,
3987.00928,2868.598,5065.58105,2200.840,
3987.10083,2867.598,5065.67285,2199.840,
3987.19238,2868.598,5065.76416,2198.840,
3987.28394,2867.598,5065.85547,2198.840,
3987.37524,2867.598,5065.94727,2197.840,
3987.46680,2867.598,5066.03857,2197.840,
3987.55835,2867.598,5066.13037,2197.840,
3987.64990,2867.598,5066.22168,2196.840,
3987.74146,2867.598,5066.31348,2196.840,
3987.83301,2867.598,5066.40479,2196.840,
3987.92456,2867.598,5066.49609,2194.840,
3988.01587,2867.598,5066.58789,2194.840,
3988.10742,2867.598,5066.67920,2194.840,
3988.19897,2867.598,5066.77100,2194.840,
3988.29053,2868.598,5066.86230,2194.840,
3988.38208,2867.598,5066.95410,2194.840,
3988.47363,2867.598,5067.04541,2193.840,
3988.56519,2867.598,5067.13721,2193.840,
3988.65674,2867.598,5067.22852,2193.840,
3988.74805,2867.598,5067.31982,2193.840,
3988.83960,2866.598,5067.41162,2192.840,
3988.93115,2866.598,5067.50293,2193.840,
3989.02271,2867.598,5067.59473,2192.840,
3989.11426,2866.598,5067.68604,2192.840,
3989.20581,2866.598,5067.77783,2192.840,
3989.29736,2866.598,5067.86914,2191.840,
3989.38892,2866.598,5067.96045,2191.840,
3989.48022,2866.598,5068.05225,2191.840,
3989.57178,2866.598,5068.14355,2190.840,
3989.66333,2866.598,5068.23535,2190.840,
3989.75488,2865.598,5068.32666,2189.840,
3989.84644,2866.598,5068.41846,2190.840,
3989.93799,2866.598,5068.50977,2189.840,
3990.02954,2865.598,5068.60107,2189.840,
3990.12085,2865.598,5068.69287,2189.840,
3990.21240,2866.598,5068.78418,2188.840,
3990.30396,2865.598,5068.87598,2188.840,
3990.39551,2865.598,5068.96729,2188.840,
3990.48706,2865.598,5069.05908,2187.840,
3990.57861,2865.598,5069.15039,2187.840,
3990.67017,2865.598,5069.24170,2187.840,
3990.76172,2865.598,5069.33350,2187.840,
3990.85303,2865.598,5069.42480,2186.840,
3990.94458,2865.598,5069.51660,2186.840,
3991.03613,2865.598,5069.60791,2186.840,
3991.12769,2865.598,5069.69971,2185.840,
3991.21924,2865.598,5069.79102,2185.840,
3991.31079,2864.598,5069.88281,2185.840,
3991.40234,2864.598,5069.97412,2184.840,
3991.49390,2865.598,5070.06543,2184.840,
3991.58521,2864.598,5070.15723,2184.840,
3991.67676,2865.598,5070.24854,2183.840,
3991.76831,2865.598,5070.34033,2183.840,
3991.85986,2864.598,5070.43164,2184.840,
3991.95142,2864.598,5070.52344,2183.840,
3992.04297,2864.598,5070.61475,2182.840,
3992.13452,2864.598,5070.70605,2182.840,
3992.22583,2864.598,5070.79785,2182.840,
3992.31738,2864.598,5070.88916,2182.840,
3992.40894,2864.598,5070.98096,2181.840,
3992.50049,2864.598,5071.07227,2181.840,
3992.59204,2864.598,5071.16406,2181.840,
3992.68359,2865.598,5071.25537,2181.840,
3992.77515,2864.598,5071.34668,2180.840,
3992.86670,2864.598,5071.43848,2180.840,
3992.95801,2864.598,5071.52979,2180.840,
3993.04956,2864.598,5071.62158,2179.840,
3993.14111,2863.598,5071.71289,2179.840,
3993.23267,2863.598,5071.80469,2179.840,
3993.32422,2863.598,5071.89600,2179.840,
3993.41577,2863.598,5071.98779,2178.840,
3993.50732,2863.598,5072.07910,2178.840,
3993.59863,2863.598,5072.17041,2178.840,
3993.69019,2863.598,5072.26221,2177.840,
3993.78174,2863.598,5072.35352,2177.840,
3993.87329,2863.598,5072.44531,2177.840,
3993.96484,2863.598,5072.53662,2176.840,
3994.05640,2863.598,5072.62842,2176.840,
3994.14795,2864.598,5072.71973,2176.840,
3994.23950,2863.598,5072.81104,2175.840,
3994.33081,2863.598,5072.90283,2176.840,
3994.42236,2863.598,5072.99414,2175.840,
3994.51392,2863.598,5073.08594,2174.840,
3994.60547,2863.598,5073.17725,2174.840,
3994.69702,2863.598,5073.26904,2174.840,
3994.78857,2863.598,5073.36035,2175.840,
3994.88013,2862.598,5073.45166,2173.840,
3994.97168,2863.598,5073.54346,2173.840,
3995.06299,2862.598,5073.63477,2173.840,
3995.15454,2863.598,5073.72656,2172.840,
3995.24609,2863.598,5073.81787,2173.840,
3995.33765,2862.598,5073.90967,2172.840,
3995.42920,2862.598,5074.00098,2172.840,
3995.52075,2862.598,5074.09277,2171.840,
3995.61230,2863.598,5074.18408,2172.840,
3995.70361,2862.598,5074.27539,2171.840,
3995.79517,2862.598,5074.36719,2170.840,
3995.88672,2862.598,5074.45850,2170.840,
3995.97827,2861.598,5074.55029,2170.840,
3996.06982,2861.598,5074.64160,2169.840,
3996.16138,2861.598,5074.73340,2169.840,
3996.25293,2861.598,5074.82471,2170.840,
3996.34448,2861.598,5074.91602,2169.840,
3996.43579,2861.598,5075.00781,2168.840,
3996.52734,2861.598,5075.09912,2168.840,
3996.61890,2861.598,5075.19092,2168.840,
3996.71045,2861.598,5075.28223,2167.840,
3996.80200,2861.598,5075.37402,2168.840,
3996.89355,2861.598,5075.46533,2167.840,
3996.98511,2860.598,5075.55664,2167.840,
3997.07666,2861.598,5075.64844,2166.840,
3997.16797,2861.598,5075.73975,2166.840,
3997.25952,2861.598,5075.83154,2165.840,
3997.35107,2861.598,5075.92285,2165.840,
3997.44263,2861.598,5076.01465,2165.840,
3997.53418,2860.598,5076.10596,2165.840,
3997.62573,2860.598,5076.19775,2164.840,
3997.71729,2861.598,5076.28906,2165.840,
3997.80859,2860.598,5076.38037,2163.840,
3997.90015,2860.598,5076.47217,2164.840,
3997.99170,2861.598,5076.56348,2163.840,
3998.08325,2860.598,5076.65527,2163.840,
3998.17480,2860.598,5076.74658,2163.840,
3998.26636,2860.598,5076.83838,2163.840,
3998.35791,2860.598,5076.92969,2162.840,
3998.44946,2859.598,5077.02100,2162.840,
3998.54077,2861.598,5077.11279,2162.840,
3998.63232,2860.598,5077.20410,2161.840,
3998.72388,2860.598,5077.29590,2161.840,
3998.81543,2860.598,5077.38721,2161.840,
3998.90698,2860.598,5077.47900,2161.840,
3998.99854,2860.598,5077.57031,2160.840,
3999.09009,2860.598,5077.66162,2159.840,
3999.18164,2859.598,5077.75342,2160.840,
3999.27295,2859.598,5077.84473,2159.840,
3999.36450,2859.598,5077.93652,2159.840,
3999.45605,2859.598,5078.02783,2158.840,
3999.54761,2859.598,5078.11963,2158.840,
3999.63916,2859.598,5078.21094,2158.840,
3999.73071,2859.598,5078.30273,2158.840,
3999.82227,2858.598,5078.39404,2158.840,
3999.91357,2859.598,5078.48535,2157.840,
4000.00513,2859.598,5078.57715,2157.840,
4000.09668,2859.598,5078.66846,2157.840,
4000.18823,2859.598,5078.76025,2157.840,
4000.27979,2859.598,5078.85156,2155.840,
4000.37134,2859.598,5078.94336,2155.840,
4000.46289,2858.598,5079.03467,2155.840,
4000.55444,2859.598,5079.12598,2155.840,
4000.64575,2858.598,5079.21777,2155.840,
4000.73730,2858.598,5079.30908,2154.840,
4000.82886,2859.598,5079.40088,2154.840,
4000.92041,2858.598,5079.49219,2154.840,
4001.01196,2858.598,5079.58398,2154.840,
4001.10352,2858.598,5079.67529,2154.840,
4001.19507,2858.598,5079.76660,2153.840,
4001.28638,2859.598,5079.85840,2153.840,
4001.37793,2858.598,5079.94971,2152.840,
4001.46948,2859.598,5080.04150,2152.840,
4001.56104,2858.598,5080.13281,2151.840,
4001.65259,2857.598,5080.22461,2152.840,
4001.74414,2858.598,5080.31592,2151.840,
4001.83569,2858.598,5080.40771,2150.840,
4001.92725,2857.598,5080.49902,2149.840,
4002.01855,2858.598,5080.59033,2149.840,
4002.11011,2858.598,5080.68213,2149.840,
4002.20166,2857.598,5080.77344,2148.840,
4002.29321,2857.598,5080.86523,2146.840,
4002.38477,2857.598,5080.95654,2147.840,
4002.47632,2857.598,5081.04834,2146.840,
4002.56787,2856.598,5081.13965,2146.840,
4002.65942,2856.598,5081.23096,2146.840,
4002.75073,2857.598,5081.32275,2145.840,
4002.84229,2856.598,5081.41406,2145.840,
4002.93384,2857.598,5081.50586,2145.840,
4003.02539,2856.598,5081.59717,2145.840,
4003.11694,2855.598,5081.68896,2145.840,
4003.20850,2855.598,5081.78027,2144.840,
4003.30005,2855.598,5081.87158,2145.840,
4003.39136,2854.598,5081.96338,2145.840,
4003.48291,2854.598,5082.05469,2144.840,
4003.57446,2854.598,5082.14648,2144.840,
4003.66602,2854.598,5082.23779,2144.840,
4003.75757,2854.598,5082.32959,2144.840,
4003.84912,2853.598,5082.42090,2143.840,
4003.94067,2854.598,5082.51221,2144.840,
4004.03223,2853.598,5082.60400,2143.840,
4004.12354,2854.598,5082.69531,2143.840,
4004.21509,2854.598,5082.78711,2144.840,
4004.30664,2854.598,5082.87842,2144.840,
4004.39819,2855.598,5082.97021,2145.840,
4004.48975,2854.598,5083.06152,2145.840,
4004.58130,2854.598,5083.15332,2144.840,
4004.67285,2855.598,5083.24463,2144.840,
4004.76440,2855.598,5083.33594,2143.840,
4004.85571,2855.598,5083.42773,2143.840,
4004.94727,2854.598,5083.51904,2142.840,
4005.03882,2854.598,5083.61084,2142.840,
4005.13037,2854.598,5083.70215,2141.840,
4005.22192,2854.598,5083.79395,2141.840,
4005.31348,2855.598,5083.88525,2140.840,
4005.40503,2854.598,5083.97656,2140.840,
4005.49634,2855.598,5084.06836,2139.840,
4005.58789,2855.598,5084.15967,2139.840,
4005.67944,2855.598,5084.25146,2139.840,
4005.77100,2856.598,5084.34277,2138.840,
4005.86255,2856.598,5084.43457,2137.840,
4005.95410,2856.598,5084.52588,2137.840,
4006.04565,2855.598,5084.61719,2136.840,
4006.13721,2855.598,5084.70898,2136.840,
4006.22852,2855.598,5084.80029,2136.840,
4006.32007,2854.598,5084.89209,2135.840,
4006.41162,2854.598,5084.98340,2135.840,
4006.50317,2854.598,5085.07520,2136.840,
4006.59473,2854.598,5085.16650,2135.840,
4006.68628,2853.598,5085.25830,2135.840,
4006.77783,2853.598,5085.34961,2134.840,
4006.86914,2854.598,5085.44092,2134.840,
4006.96069,2853.598,5085.53271,2134.840,
4007.05225,2853.598,5085.62402,2134.840,
4007.14380,2853.598,5085.71582,2133.840,
4007.23535,2853.598,5085.80713,2132.840,
4007.32690,2853.598,5085.89893,2133.840,
4007.41846,2853.598,5085.99023,2132.840,
4007.51001,2853.598,5086.08154,2132.840,
4007.60132,2853.598,5086.17334,2132.840,
4007.69287,2853.598,5086.26465,2131.840,
4007.78442,2853.598,5086.35645,2131.840,
4007.87598,2852.598,5086.44775,2131.840,
4007.96753,2853.598,5086.53955,2131.840,
4008.05908,2853.598,5086.63086,2130.840,
4008.15063,2853.598,5086.72217,2130.840,
4008.24219,2852.598,5086.81396,2129.840,
4008.33350,2853.598,5086.90527,2129.840,
4008.42505,2852.598,5086.99707,2129.840,
4008.51660,2852.598,5087.08838,2129.840,
4008.60815,2853.598,5087.18018,2128.840,
4008.69971,2852.598,5087.27148,2128.840,
4008.79126,2853.598,5087.36328,2128.840,
4008.88281,2852.598,5087.45459,2128.840,
4008.97412,2852.598,5087.54590,2127.840,
4009.06567,2852.598,5087.63770,2127.840,
4009.15723,2852.598,5087.72900,2127.840,
4009.24878,2851.598,5087.82080,2126.840,
4009.34033,2852.598,5087.91211,2126.840,
4009.43188,2852.598,5088.00391,2126.840,
4009.52344,2851.598,5088.09521,2125.840,
4009.61499,2851.598,5088.18652,2125.840,
4009.70630,2852.598,5088.27832,2125.840,
4009.79785,2851.598,5088.36963,2125.840,
4009.88940,2851.598,5088.46143,2124.840,
4009.98096,2851.598,5088.55273,2124.840,
4010.07251,2851.598,5088.64453,2124.840,
4010.16406,2851.598,5088.73584,2123.840,
4010.25562,2851.598,5088.82715,2123.840,
4010.34717,2851.598,5088.91895,2123.840,
4010.43848,2851.598,5089.01025,2122.840,
4010.53003,2850.598,5089.10205,2122.840,
4010.62158,2851.598,5089.19336,2122.840,
4010.71313,2850.598,5089.28516,2122.840,
4010.80469,2850.598,5089.37646,2121.840,
4010.89624,2850.598,5089.46826,2122.840,
4010.98779,2850.598,5089.55957,2121.840,
4011.07910,2850.598,5089.65088,2120.840,
4011.17065,2850.598,5089.74268,2120.840,
4011.26221,2849.598,5089.83398,2120.840,
4011.35376,2850.598,5089.92578,2120.840,
4011.44531,2849.598,5090.01709,2120.840,
4011.53687,2849.598,5090.10889,2119.840,
4011.62842,2849.598,5090.20020,2119.840,
4011.71997,2850.598,5090.29150,2118.840,
4011.81128,2849.598,5090.38330,2118.840,
4011.90283,2849.598,5090.47461,2118.840,
4011.99438,2849.598,5090.56641,2117.840,
4012.08594,2849.598,5090.65771,2117.840,
4012.17749,2849.598,5090.74951,2117.840,
4012.26904,2849.598,5090.84082,2116.840,
4012.36060,2849.598,5090.93213,2116.840,
4012.45190,2849.598,5091.02393,2116.840,
4012.54346,2849.598,5091.11523,2116.840,
4012.63501,2848.598,5091.20703,2115.840,
4012.72656,2849.598,5091.29834,2114.840,
4012.81812,2849.598,5091.39014,2114.840,
4012.90967,2848.598,5091.48145,2114.840,
4013.00122,2848.598,5091.57324,2114.840,
4013.09277,2848.598,5091.66455,2113.840,
4013.18408,2849.598,5091.75586,2113.840,
4013.27563,2848.598,5091.84766,2113.840,
4013.36719,2848.598,5091.93896,2112.840,
4013.45874,2848.598,5092.03076,2112.840,
4013.55029,2848.598,5092.12207,2112.840,
4013.64185,2848.598,5092.21387,2112.840,
4013.73340,2847.598,5092.30518,2111.840,
4013.82495,2848.598,5092.39648,2112.840,
4013.91626,2848.598,5092.48828,2111.840,
4014.00781,2847.598,5092.57959,2110.840,
4014.09937,2847.598,5092.67139,2110.840,
4014.19092,2847.598,5092.76270,2110.840,
4014.28247,2847.598,5092.85449,2109.840,
4014.37402,2847.598,5092.94580,2109.840,
4014.46558,2847.598,5093.03711,2109.840,
4014.55688,2847.598,5093.12891,2109.840,
4014.64844,2848.598,5093.22021,2108.840,
4014.73999,2847.598,5093.31201,2108.840,
4014.83154,2847.598,5093.40332,2108.840,
4014.92310,2847.598,5093.49512,2107.840,
4015.01465,2847.598,5093.58643,2107.840,
4015.10620,2847.598,5093.67822,2106.840,
4015.19775,2846.598,5093.76953,2106.840,
4015.28906,2847.598,5093.86084,2107.840,
4015.38062,2846.598,5093.95264,2106.840,
4015.47217,2847.598,5094.04395,2105.840,
4015.56372,2847.598,5094.13574,2105.840,
4015.65527,2846.598,5094.22705,2106.840,
4015.74683,2846.598,5094.31885,2105.840,
4015.83838,2845.598,5094.41016,2105.840,
4015.92993,2846.598,5094.50146,2104.840,
4016.02124,2845.598,5094.59326,2104.840,
4016.11279,2847.598,5094.68457,2103.840,
4016.20435,2845.598,5094.77637,2103.840,
4016.29590,2845.598,5094.86768,2103.840,
4016.38745,2846.598,5094.95947,2103.840,
4016.47900,2845.598,5095.05078,2102.840,
4016.57056,2845.598,5095.14209,2102.840,
4016.66187,2846.598,5095.23389,2102.840,
4016.75342,2845.598,5095.32520,2102.840,
4016.84497,2845.598,5095.41699,2101.840,
4016.93652,2845.598,5095.50830,2101.840,
4017.02808,2845.598,5095.60010,2100.840,
4017.11963,2844.598,5095.69141,2100.840,
4017.21118,2844.598,5095.78271,2100.840,
4017.30273,2844.598,5095.87451,2100.840,
4017.39404,2844.598,5095.96582,2099.840,
4017.48560,2844.598,5096.05762,2099.840,
4017.57715,2845.598,5096.14893,2099.840,
4017.66870,2844.598,5096.24072,2098.840,
4017.76025,2844.598,5096.33203,2098.840,
4017.85181,2844.598,5096.42383,2098.840,
4017.94336,2843.598,5096.51514,2097.840,
4018.03491,2844.598,5096.60645,2097.840,
4018.12622,2844.598,5096.69824,2097.840,
4018.21777,2844.598,5096.78955,2097.840,
4018.30933,2844.598,5096.88135,2097.840,
4018.40088,2843.598,5096.97266,2097.840,
4018.49243,2843.598,5097.06445,2095.840,
4018.58398,2843.598,5097.15576,2096.840,
4018.67554,2843.598,5097.24707,2095.840,
4018.76685,2843.598,5097.33887,2095.840,
4018.85840,2843.598,5097.43018,2094.840,
4018.94995,2843.598,5097.52197,2094.840,
4019.04150,2843.598,5097.61328,2094.840,
4019.13306,2843.598,5097.70508,2093.840,
4019.22461,2843.598,5097.79639,2093.840,
4019.31616,2843.598,5097.88770,2092.840,
4019.40771,2843.598,5097.97949,2092.840,
4019.49902,2842.598,5098.07080,2092.840,
4019.59058,2843.598,5098.16260,2091.840,
4019.68213,2842.598,5098.25391,2092.840,
4019.77368,2842.598,5098.34570,2091.840,
4019.86523,2842.598,5098.43701,2091.840,
4019.95679,2842.598,5098.52881,2091.840,
4020.04834,2842.598,5098.62012,2091.840,
4020.13965,2842.598,5098.71143,2090.840,
4020.23120,2842.598,5098.80322,2090.840,
4020.32275,2842.598,5098.89453,2089.840,
4020.41431,2842.598,5098.98633,2090.840,
4020.50586,2843.598,5099.07764,2089.840,
4020.59741,2842.598,5099.16943,2089.840,
4020.68896,2841.598,5099.26074,2089.840,
4020.78052,2842.598,5099.35205,2089.840,
4020.87183,2842.598,5099.44385,2088.840,
4020.96338,2841.598,5099.53516,2088.840,
4021.05493,2841.598,5099.62695,2087.840,
4021.14648,2841.598,5099.71826,2088.840,
4021.23804,2842.598,5099.81006,2087.840,
4021.32959,2841.598,5099.90137,2087.840,
4021.42114,2842.598,5099.99268,2086.840,
4021.51270,2841.598,5100.08447,2085.840,
4021.60400,2841.598,5100.17578,2086.840,
4021.69556,2841.598,5100.26758,2085.840,
4021.78711,2841.598,5100.35889,2085.840,
4021.87866,2841.598,5100.45068,2083.840,
4021.97021,2841.598,5100.54199,2083.840,
4022.06177,2840.598,5100.63379,2081.840,
4022.15332,2840.598,5100.72510,2080.840,
4022.24463,2840.598,5100.81641,2080.840,
4022.33618,2840.598,5100.90820,2079.840,
4022.42773,2839.598,5100.99951,2078.840,
4022.51929,2840.598,5101.09131,2078.840,
4022.61084,2840.598,5101.18262,2079.840,
4022.70239,2840.598,5101.27441,2078.840,
4022.79395,2839.598,5101.36572,2077.840,
4022.88550,2839.598,5101.45703,2077.840,
4022.97681,2839.598,5101.54883,2077.840,
4023.06836,2839.598,5101.64014,2077.840,
4023.15991,2839.598,5101.73193,2078.840,
4023.25146,2839.598,5101.82324,2077.840,
4023.34302,2839.598,5101.91504,2077.840,
4023.43457,2840.598,5102.00635,2078.840,
4023.52612,2839.598,5102.09766,2077.840,
4023.61768,2839.598,5102.18945,2077.840,
4023.70898,2839.598,5102.28076,2077.840,
4023.80054,2839.598,5102.37256,2077.840,
4023.89209,2839.598,5102.46387,2077.840,
4023.98364,2840.598,5102.55566,2077.840,
4024.07520,2840.598,5102.64697,2078.840,
4024.16675,2841.598,5102.73877,2077.840,
4024.25830,2841.598,5102.83008,2077.840,
4024.34961,2841.598,5102.92139,2076.840,
4024.44116,2841.598,5103.01318,2076.840,
4024.53271,2841.598,5103.10449,2075.840,
4024.62427,2841.598,5103.19629,2076.840,
4024.71582,2841.598,5103.28760,2075.840,
4024.80737,2840.598,5103.37939,2075.840,
4024.89893,2841.598,5103.47070,2075.840,
4024.99048,2840.598,5103.56201,2074.840,
4025.08179,2840.598,5103.65381,2074.840,
4025.17334,2840.598,5103.74512,2073.840,
4025.26489,2839.598,5103.83691,2074.840,
4025.35645,2839.598,5103.92822,2073.840,
4025.44800,2839.598,5104.02002,2072.840,
4025.53955,2838.598,5104.11133,2073.840,
4025.63110,2838.598,5104.20264,2072.840,
4025.72241,2838.598,5104.29443,2072.840,
4025.81396,2837.598,5104.38574,2072.840,
4025.90552,2837.598,5104.47754,2071.840,
4025.99707,2837.598,5104.56885,2071.840,
4026.08862,2837.598,5104.66064,2070.840,
4026.18018,2836.598,5104.75195,2070.840,
4026.27173,2836.598,5104.84375,2069.840,
4026.36328,2837.598,5104.93506,2070.840,
4026.45459,2837.598,5105.02637,2069.840,
4026.54614,2836.598,5105.11816,2069.840,
4026.63770,2836.598,5105.20947,2069.840,
4026.72925,2836.598,5105.30127,2068.840,
4026.82080,2836.598,5105.39258,2068.840,
4026.91235,2836.598,5105.48438,2067.840,
4027.00391,2836.598,5105.57568,2068.840,
4027.09546,2836.598,5105.66699,2068.840,
4027.18677,2836.598,5105.75879,2067.840,
4027.27832,2836.598,5105.85010,2067.840,
4027.36987,2835.598,5105.94189,2066.840,
4027.46143,2835.598,5106.03320,2066.840,
4027.55298,2835.598,5106.12500,2065.840,
4027.64453,2835.598,5106.21631,2065.840,
4027.73608,2835.598,5106.30762,2065.840,
4027.82739,2836.598,5106.39941,2065.840,
4027.91895,2835.598,5106.49072,2064.840,
4028.01050,2835.598,5106.58252,2064.840,
4028.10205,2835.598,5106.67383,2063.840,
4028.19360,2835.598,5106.76563,2063.840,
4028.28516,2834.598,5106.85693,2063.840,
4028.37671,2835.598,5106.94824,2063.840,
4028.46826,2835.598,5107.04004,2063.840,
4028.55957,2834.598,5107.13135,2063.840,
4028.65112,2834.598,5107.22314,2062.840,
4028.74268,2835.598,5107.31445,2061.840,
4028.83423,2834.598,5107.40625,2062.840,
4028.92578,2834.598,5107.49756,2061.840,
4029.01733,2833.598,5107.58936,2060.840,
4029.10889,2834.598,5107.68066,2060.840,
4029.20044,2833.598,5107.77197,2060.840,
4029.29175,2834.598,5107.86377,2060.840,
4029.38330,2834.598,5107.95508,2059.840,
4029.47485,2833.598,5108.04688,2059.840,
4029.56641,2833.598,5108.13818,2059.840,
4029.65796,2833.598,5108.22998,2058.840,
4029.74951,2833.598,5108.32129,2058.840,
4029.84106,2833.598,5108.41260,2058.840,
4029.93237,2833.598,5108.50439,2058.840,
4030.02393,2833.598,5108.59570,2058.840,
4030.11548,2833.598,5108.68750,2057.840,
4030.20703,2833.598,5108.77881,2057.840,
4030.29858,2833.598,5108.87061,2056.840,
4030.39014,2832.598,5108.96191,2056.840,
4030.48169,2832.598,5109.05322,2056.840,
4030.57324,2832.598,5109.14502,2055.840,
4030.66455,2832.598,5109.23633,2055.840,
4030.75610,2833.598,5109.32813,2054.840,
4030.84766,2832.598,5109.41943,2054.840,
4030.93921,2832.598,5109.51123,2054.840,
4031.03076,2832.598,5109.60254,2054.840,
4031.12231,2832.598,5109.69434,2053.840,
4031.21387,2832.598,5109.78564,2053.840,
4031.30518,2832.598,5109.87695,2053.840,
4031.39673,2831.598,5109.96875,2053.840,
4031.48828,2832.598,5110.06006,2053.840,
4031.57983,2832.598,5110.15186,2052.840,
4031.67139,2831.598,5110.24316,2051.840,
4031.76294,2831.598,5110.33496,2052.840,
4031.85449,2831.598,5110.42627,2052.840,
4031.94604,2831.598,5110.51758,2051.840,
4032.03735,2831.598,5110.60938,2050.840,
4032.12891,2831.598,5110.70068,2051.840,
4032.22046,2831.598,5110.79248,2050.840,
4032.31201,2831.598,5110.88379,2049.840,
4032.40356,2831.598,5110.97559,2049.840,
4032.49512,2831.598,5111.06689,2049.840,
4032.58667,2830.598,5111.15820,2048.840,
4032.67822,2831.598,5111.25000,2048.840,
4032.76953,2831.598,5111.34131,2048.840,
4032.86108,2830.598,5111.43311,2048.840,
4032.95264,2831.598,5111.52441,2047.840,
4033.04419,2830.598,5111.61621,2047.840,
4033.13574,2830.598,5111.70752,2047.840,
4033.22729,2830.598,5111.79932,2046.840,
4033.31885,2830.598,5111.89063,2046.840,
4033.41016,2830.598,5111.98193,2046.840,
4033.50171,2829.598,5112.07373,2045.840,
4033.59326,2829.598,5112.16504,2045.840,
4033.68481,2830.598,5112.25684,2045.840,
4033.77637,2829.598,5112.34814,2044.840,
4033.86792,2829.598,5112.43994,2044.840,
4033.95947,2829.598,5112.53125,2044.840,
4034.05103,2829.598,5112.62256,2043.840,
4034.14233,2829.598,5112.71436,2043.840,
4034.23389,2829.598,5112.80566,2043.840,
4034.32544,2829.598,5112.89746,2043.840,
4034.41699,2829.598,5112.98877,2042.840,
4034.50854,2828.598,5113.08057,2042.840,
4034.60010,2828.598,5113.17188,2041.840,
4034.69165,2828.598,5113.26318,2042.840,
4034.78320,2828.598,5113.35498,2041.840,
4034.87451,2828.598,5113.44629,2041.840,
4034.96606,2828.598,5113.53809,2041.840,
4035.05762,2828.598,5113.62939,2040.840,
4035.14917,2828.598,5113.72119,2040.840,
4035.24072,2828.598,5113.81250,2039.840,
4035.33228,2827.598,5113.90430,2040.840,
4035.42383,2827.598,5113.99561,2039.840,
4035.51514,2827.598,5114.08691,2039.840,
4035.60669,2827.598,5114.17871,2039.840,
4035.69824,2827.598,5114.27002,2038.840,
4035.78979,2827.598,5114.36182,2039.840,
4035.88135,2827.598,5114.45313,2038.840,
4035.97290,2827.598,5114.54492,2038.840,
4036.06445,2827.598,5114.63623,2038.840,
4036.15601,2827.598,5114.72754,2037.840,
4036.24731,2827.598,5114.81934,2036.840,
4036.33887,2826.598,5114.91064,2037.840,
4036.43042,2826.598,5115.00244,2036.840,
4036.52197,2826.598,5115.09375,2035.840,
4036.61353,2827.598,5115.18555,2035.840,
4036.70508,2826.598,5115.27686,2035.840,
4036.79663,2826.598,5115.36816,2035.840,
4036.88818,2826.598,5115.45996,2034.840,
4036.97949,2826.598,5115.55127,2034.840,
4037.07104,2826.598,5115.64307,2034.840,
4037.16260,2826.598,5115.73438,2033.840,
4037.25415,2825.598,5115.82617,2033.840,
4037.34570,2825.598,5115.91748,2033.840,
4037.43726,2825.598,5116.00928,2033.840,
4037.52881,2825.598,5116.10059,2033.840,
4037.62012,2825.598,5116.19189,2033.840,
4037.71167,2825.598,5116.28369,2033.840,
4037.80322,2825.598,5116.37500,2033.840,
4037.89478,2824.598,5116.46680,2033.840,
4037.98633,2825.598,5116.55811,2032.840,
4038.07788,2825.598,5116.64990,2032.840,
4038.16943,2825.598,5116.74121,2032.840,
4038.26099,2825.598,5116.83252,2031.840,
4038.35229,2825.598,5116.92432,2030.840,
4038.44385,2824.598,5117.01563,2030.840,
4038.53540,2824.598,5117.10742,2030.840,
4038.62695,2824.598,5117.19873,2029.840,
4038.71851,2824.598,5117.29053,2029.840,
4038.81006,2824.598,5117.38184,2028.840,
4038.90161,2824.598,5117.47314,2027.840,
4038.99292,2823.598,5117.56494,2028.840,
4039.08447,2823.598,5117.65625,2027.840,
4039.17603,2823.598,5117.74805,2026.840,
4039.26758,2823.598,5117.83936,2026.840,
4039.35913,2823.598,5117.93115,2026.840,
4039.45068,2823.598,5118.02246,2025.840,
4039.54224,2823.598,5118.11426,2025.840,
4039.63379,2823.598,5118.20557,2025.840,
4039.72510,2823.598,5118.29688,2025.840,
4039.81665,2823.598,5118.38867,2025.840,
4039.90820,2822.598,5118.47998,2025.840,
4039.99976,2823.598,5118.57178,2025.840,
4040.09131,2822.598,5118.66309,2026.840,
4040.18286,2822.598,5118.75488,2027.840,
4040.27441,2823.598,5118.84619,2026.840,
4040.36597,2823.598,5118.93750,2026.840,
4040.45728,2823.598,5119.02930,2026.840,
4040.54883,2823.598,5119.12061,2026.840,
4040.64038,2823.598,5119.21240,2025.840,
4040.73193,2823.598,5119.30371,2024.840,
4040.82349,2823.598,5119.39551,2024.840,
4040.91504,2823.598,5119.48682,2023.840,
4041.00659,2823.598,5119.57813,2023.840,
4041.09790,2822.598,5119.66992,2022.840,
4041.18945,2822.598,5119.76123,2021.840,
4041.28101,2822.598,5119.85303,2020.840,
4041.37256,2821.598,5119.94434,2019.840,
4041.46411,2821.598,5120.03613,2020.840,
4041.55566,2821.598,5120.12744,2019.840,
4041.64722,2821.598,5120.21875,2019.840,
4041.73877,2821.598,5120.31055,2018.840,
4041.83008,2821.598,5120.40186,2018.840,
4041.92163,2820.598,5120.49365,2017.840,
4042.01318,2820.598,5120.58496,2017.840,
4042.10474,2820.598,5120.67676,2017.840,
4042.19629,2820.598,5120.76807,2016.840,
4042.28784,2819.598,5120.85986,2016.840,
4042.37939,2820.598,5120.95117,2016.840,
4042.47095,2821.598,5121.04248,2015.840,
4042.56226,2819.598,5121.13428,2015.840,
4042.65381,2820.598,5121.22559,2015.840,
4042.74536,2819.598,5121.31738,2014.840,
4042.83691,2819.598,5121.40869,2014.840,
4042.92847,2819.598,5121.50049,2014.840,
4043.02002,2820.598,5121.59180,2013.840,
4043.11157,2819.598,5121.68311,2014.840,
4043.20288,2820.598,5121.77490,2013.840,
4043.29443,2819.598,5121.86621,2013.840,
4043.38599,2819.598,5121.95801,2012.840,
4043.47754,2819.598,5122.04932,2013.840,
4043.56909,2819.598,5122.14111,2012.840,
4043.66064,2819.598,5122.23242,2012.840,
4043.75220,2819.598,5122.32373,2011.840,
4043.84375,2819.598,5122.41553,2011.840,
4043.93506,2820.598,5122.50684,2010.840,
4044.02661,2819.598,5122.59863,2010.840,
4044.11816,2819.598,5122.68994,2010.840,
4044.20972,2818.598,5122.78174,2010.840,
4044.30127,2818.598,5122.87305,2009.840,
4044.39282,2818.598,5122.96484,2009.840,
4044.48438,2818.598,5123.05615,2009.840,
4044.57568,2818.598,5123.14746,2009.840,
4044.66724,2817.598,5123.23926,2008.840,
4044.75879,2817.598,5123.33057,2008.840,
4044.85034,2817.598,5123.42236,2007.840,
4044.94189,2817.598,5123.51367,2007.840,
4045.03345,2817.598,5123.60547,2007.840,
4045.12500,2816.598,5123.69678,2006.840,
4045.21655,2816.598,5123.78809,2006.840,
4045.30786,2816.598,5123.87988,2006.840,
4045.39941,2817.598,5123.97119,2006.840,
4045.49097,2816.598,5124.06299,2005.840,
4045.58252,2816.598,5124.15430,2005.840,
4045.67407,2816.598,5124.24609,2005.840,
4045.76563,2816.598,5124.33740,2004.840,
4045.85718,2816.598,5124.42871,2004.840,
4045.94873,2816.598,5124.52051,2003.840,
4046.04004,2816.598,5124.61182,2004.840,
4046.13159,2815.598,5124.70361,2003.840,
4046.22314,2815.598,5124.79492,2002.840,
4046.31470,2815.598,5124.88672,2002.840,
4046.40625,2814.598,5124.97803,2002.840,
4046.49780,2815.598,5125.06982,2002.840,
4046.58936,2815.598,5125.16113,2002.840,
4046.68066,2814.598,5125.25244,2001.840,
4046.77222,2814.598,5125.34424,2001.840,
4046.86377,2815.598,5125.43555,2001.840,
4046.95532,2814.598,5125.52734,2000.840,
4047.04688,2814.598,5125.61865,2000.840,
4047.13843,2813.598,5125.71045,1999.840,
4047.22998,2814.598,5125.80176,1999.840,
4047.32153,2813.598,5125.89307,1999.840,
4047.41284,2813.598,5125.98486,1999.840,
4047.50439,2813.598,5126.07617,1998.840,
4047.59595,2813.598,5126.16797,1998.840,
4047.68750,2813.598,5126.25928,1998.840,
4047.77905,2813.598,5126.35107,1998.840,
4047.87061,2813.598,5126.44238,1997.840,
4047.96216,2813.598,5126.53369,1997.840,
4048.05371,2813.598,5126.62549,1997.840,
4048.14502,2813.598,5126.71680,1996.840,
4048.23657,2812.598,5126.80859,1996.840,
4048.32813,2813.598,5126.89990,1996.840,
4048.41968,2813.598,5126.99170,1995.840,
4048.51123,2812.598,5127.08301,1995.840,
4048.60278,2813.598,5127.17480,1995.840,
4048.69434,2812.598,5127.26611,1994.840,
4048.78564,2812.598,5127.35742,1994.840,
4048.87720,2812.598,5127.44922,1994.840,
4048.96875,2812.598,5127.54053,1994.840,
4049.06030,2811.598,5127.63232,1994.840,
4049.15186,2811.598,5127.72363,1993.840,
4049.24341,2811.598,5127.81543,1992.840,
4049.33496,2811.598,5127.90674,1992.840,
4049.42651,2811.598,5127.99805,1992.840,
4049.51782,2811.598,5128.08984,1992.840,
4049.60938,2811.598,5128.18115,1992.840,
4049.70093,2811.598,5128.27295,1991.840,
4049.79248,2811.598,5128.36426,1991.840,
4049.88403,2811.598,5128.45605,1991.840,
4049.97559,2810.598,5128.54736,1990.840,
4050.06714,2811.598,5128.63867,1990.840,
4050.15845,2811.598,5128.73047,1989.840,
4050.25000,2810.598,5128.82178,1989.840,
4050.34155,2810.598,5128.91357,1989.840,
4050.43311,2810.598,5129.00488,1989.840,
4050.52466,2810.598,5129.09668,1988.840,
4050.61621,2810.598,5129.18799,1988.840,
4050.70776,2810.598,5129.27979,1988.840,
4050.79932,2810.598,5129.37109,1987.840,
4050.89063,2809.598,5129.46240,1987.840,
4050.98218,2809.598,5129.55420,1987.840,
4051.07373,2809.598,5129.64551,1986.840,
4051.16528,2809.598,5129.73730,1986.840,
4051.25684,2810.598,5129.82861,1985.840,
4051.34839,2809.598,5129.92041,1985.840,
4051.43994,2809.598,5130.01172,1985.840,
4051.53149,2809.598,5130.10303,1985.840,
4051.62280,2809.598,5130.19482,1984.840,
4051.71436,2809.598,5130.28613,1984.840,
4051.80591,2808.598,5130.37793,1984.840,
4051.89746,2808.598,5130.46924,1984.840,
4051.98901,2808.598,5130.56104,1983.840,
4052.08057,2808.598,5130.65234,1983.840,
4052.17212,2808.598,5130.74365,1982.840,
4052.26343,2808.598,5130.83545,1982.840,
4052.35498,2807.598,5130.92676,1982.840,
4052.44653,2808.598,5131.01855,1982.840,
4052.53809,2807.598,5131.10986,1982.840,
4052.62964,2807.598,5131.20166,1981.840,
4052.72119,2808.598,5131.29297,1980.840,
4052.81274,2807.598,5131.38428,1981.840,
4052.90430,2807.598,5131.47607,1980.840,
4052.99561,2807.598,5131.56738,1980.840,
4053.08716,2807.598,5131.65918,1979.840,
4053.17871,2807.598,5131.75049,1979.840,
4053.27026,2806.598,5131.84229,1979.840,
4053.36182,2807.598,5131.93359,1979.840,
4053.45337,2807.598,5132.02539,1978.840,
4053.54492,2806.598,5132.11670,1978.840,
4053.63647,2806.598,5132.20801,1977.840,
4053.72778,2806.598,5132.29980,1977.840,
4053.81934,2805.598,5132.39111,1977.840,
4053.91089,2806.598,5132.48291,1977.840,
4054.00244,2806.598,5132.57422,1976.840,
4054.09399,2805.598,5132.66602,1976.840,
4054.18555,2806.598,5132.75732,1975.840,
4054.27710,2805.598,5132.84863,1976.840,
4054.36841,2805.598,5132.94043,1975.840,
4054.45996,2805.598,5133.03174,1975.840,
4054.55151,2805.598,5133.12354,1974.840,
4054.64307,2805.598,5133.21484,1975.840,
4054.73462,2805.598,5133.30664,1974.840,
4054.82617,2805.598,5133.39795,1974.840,
4054.91772,2805.598,5133.48926,1974.840,
4055.00928,2804.598,5133.58105,1973.840,
4055.10059,2805.598,5133.67236,1973.840,
4055.19214,2804.598,5133.76416,1972.840,
4055.28369,2804.598,5133.85547,1972.840,
4055.37524,2804.598,5133.94727,1971.840,
4055.46680,2804.598,5134.03857,1971.840,
4055.55835,2803.598,5134.13037,1970.840,
4055.64990,2804.598,5134.22168,1969.840,
4055.74146,2804.598,5134.31299,1969.840,
4055.83276,2803.598,5134.40479,1968.840,
4055.92432,2803.598,5134.49609,1968.840,
4056.01587,2803.598,5134.58789,1968.840,
4056.10742,2803.598,5134.67920,1968.840,
4056.19897,2803.598,5134.77100,1967.840,
4056.29053,2803.598,5134.86230,1968.840,
4056.38208,2803.598,5134.95361,1968.840,
4056.47339,2803.598,5135.04541,1967.840,
4056.56494,2802.598,5135.13672,1967.840,
4056.65649,2803.598,5135.22852,1967.840,
4056.74805,2803.598,5135.31982,1967.840,
4056.83960,2802.598,5135.41162,1967.840,
4056.93115,2802.598,5135.50293,1966.840,
4057.02271,2802.598,5135.59424,1967.840,
4057.11426,2802.598,5135.68604,1965.840,
4057.20557,2802.598,5135.77734,1966.840,
4057.29712,2802.598,5135.86914,1965.840,
4057.38867,2801.598,5135.96045,1965.840,
4057.48022,2801.598,5136.05225,1965.840,
4057.57178,2802.598,5136.14355,1965.840,
4057.66333,2801.598,5136.23535,1964.840,
4057.75488,2801.598,5136.32666,1964.840,
4057.84619,2801.598,5136.41797,1963.840,
4057.93774,2801.598,5136.50977,1962.840,
4058.02930,2801.598,5136.60107,1961.840,
4058.12085,2801.598,5136.69287,1959.840,
4058.21240,2800.598,5136.78418,1958.840,
4058.30396,2800.598,5136.87598,1958.840,
4058.39551,2801.598,5136.96729,1958.840,
4058.48706,2800.598,5137.05859,1957.840,
4058.57837,2800.598,5137.15039,1957.840,
4058.66992,2800.598,5137.24170,1957.840,
4058.76147,2800.598,5137.33350,1957.840,
4058.85303,2799.598,5137.42480,1957.840,
4058.94458,2800.598,5137.51660,1956.840,
4059.03613,2799.598,5137.60791,1957.840,
4059.12769,2799.598,5137.69922,1956.840,
4059.21924,2799.598,5137.79102,1957.840,
4059.31055,2798.598,5137.88232,1957.840,
4059.40210,2798.598,5137.97412,1957.840,
4059.49365,2797.598,5138.06543,1956.840,
4059.58521,2799.598,5138.15723,1956.840,
4059.67676,2798.598,5138.24854,1956.840,
4059.76831,2798.598,5138.34033,1956.840,
4059.85986,2799.598,5138.43164,1956.840,
4059.95117,2798.598,5138.52295,1956.840,
4060.04272,2798.598,5138.61475,1955.840,
4060.13428,2799.598,5138.70605,1955.840,
4060.22583,2798.598,5138.79785,1955.840,
4060.31738,2798.598,5138.88916,1955.840,
4060.40894,2798.598,5138.98096,1954.840,
4060.50049,2798.598,5139.07227,1954.840,
4060.59204,2797.598,5139.16357,1954.840,
4060.68335,2797.598,5139.25537,1954.840,
4060.77490,2797.598,5139.34668,1953.840,
4060.86646,2797.598,5139.43848,1953.840,
4060.95801,2797.598,5139.52979,1953.840,
4061.04956,2797.598,5139.62158,1952.840,
4061.14111,2797.598,5139.71289,1952.840,
4061.23267,2797.598,5139.80420,1952.840,
4061.32422,2797.598,5139.89600,1951.840,
4061.41553,2798.598,5139.98730,1951.840,
4061.50708,2799.598,5140.07910,1951.840,
4061.59863,2799.598,5140.17041,1950.840,
4061.69019,2800.598,5140.26221,1950.840,
4061.78174,2799.598,5140.35352,1950.840,
4061.87329,2800.598,5140.44531,1949.840,
4061.96484,2800.598,5140.53662,1949.840,
4062.05615,2800.598,5140.62793,1948.840,
4062.14771,2799.598,5140.71973,1950.840,
4062.23926,2799.598,5140.81104,1948.840,
4062.33081,2799.598,5140.90283,1948.840,
4062.42236,2798.598,5140.99414,1948.840,
4062.51392,2798.598,5141.08594,1947.840,
4062.60547,2797.598,5141.17725,1947.840,
4062.69702,2797.598,5141.26855,1947.840,
4062.78833,2796.598,5141.36035,1946.840,
4062.87988,2796.598,5141.45166,1946.840,
4062.97144,2796.598,5141.54346,1946.840,
4063.06299,2795.598,5141.63477,1946.840,
4063.15454,2795.598,5141.72656,1945.840,
4063.24609,2795.598,5141.81787,1945.840,
4063.33765,2794.598,5141.90918,1945.840,
4063.42896,2795.598,5142.00098,1944.840,
4063.52051,2794.598,5142.09229,1943.840,
4063.61206,2794.598,5142.18408,1944.840,
4063.70361,2794.598,5142.27539,1944.840,
4063.79517,2794.598,5142.36719,1943.840,
4063.88672,2794.598,5142.45850,1943.840,
4063.97827,2794.598,5142.55029,1942.840,
4064.06982,2793.598,5142.64160,1942.840,
4064.16113,2793.598,5142.73291,1942.840,
4064.25269,2793.598,5142.82471,1942.840,
4064.34424,2793.598,5142.91602,1941.840,
4064.43579,2793.598,5143.00781,1941.840,
4064.52734,2792.598,5143.09912,1940.840,
4064.61890,2793.598,5143.19092,1940.840,
4064.71045,2792.598,5143.28223,1940.840,
4064.80200,2793.598,5143.37354,1939.840,
4064.89331,2792.598,5143.46533,1939.840,
4064.98486,2792.598,5143.55664,1939.840,
4065.07642,2792.598,5143.64844,1940.840,
4065.16797,2792.598,5143.73975,1939.840,
4065.25952,2792.598,5143.83154,1938.840,
4065.35107,2792.598,5143.92285,1937.840,
4065.44263,2791.598,5144.01416,1937.840,
4065.53394,2791.598,5144.10596,1937.840,
4065.62549,2791.598,5144.19727,1937.840,
4065.71704,2791.598,5144.28906,1936.840,
4065.80859,2791.598,5144.38037,1936.840,
4065.90015,2791.598,5144.47217,1936.840,
4065.99170,2791.598,5144.56348,1935.840,
4066.08325,2790.598,5144.65479,1935.840,
4066.17480,2791.598,5144.74658,1935.840,
4066.26611,2790.598,5144.83789,1935.840,
4066.35767,2791.598,5144.92969,1934.840,
4066.44922,2790.598,5145.02100,1934.840,
4066.54077,2790.598,5145.11279,1934.840,
4066.63232,2790.598,5145.20410,1933.840,
4066.72388,2790.598,5145.29590,1933.840,
4066.81543,2789.598,5145.38721,1933.840,
4066.90698,2789.598,5145.47852,1933.840,
4066.99829,2790.598,5145.57031,1933.840,
4067.08984,2789.598,5145.66162,1932.840,
4067.18140,2789.598,5145.75342,1932.840,
4067.27295,2789.598,5145.84473,1931.840,
4067.36450,2789.598,5145.93652,1931.840,
4067.45605,2789.598,5146.02783,1931.840,
4067.54761,2788.598,5146.11914,1930.840,
4067.63892,2788.598,5146.21094,1930.840,
4067.73047,2788.598,5146.30225,1930.840,
4067.82202,2788.598,5146.39404,1929.840,
4067.91357,2788.598,5146.48535,1929.840,
4068.00513,2788.598,5146.57715,1929.840,
4068.09668,2788.598,5146.66846,1929.840,
4068.18823,2787.598,5146.75977,1928.840,
4068.27979,2788.598,5146.85156,1928.840,
4068.37109,2788.598,5146.94287,1928.840,
4068.46265,2787.598,5147.03467,1927.840,
4068.55420,2787.598,5147.12598,1927.840,
4068.64575,2787.598,5147.21777,1926.840,
4068.73730,2787.598,5147.30908,1926.840,
4068.82886,2787.598,5147.40088,1925.840,
4068.92041,2787.598,5147.49219,1925.840,
4069.01172,2787.598,5147.58350,1925.840,
4069.10327,2786.598,5147.67529,1925.840,
4069.19482,2786.598,5147.76660,1924.840,
4069.28638,2786.598,5147.85840,1924.840,
4069.37793,2786.598,5147.94971,1923.840,
4069.46948,2787.598,5148.04150,1924.840,
4069.56104,2786.598,5148.13281,1923.840,
4069.65259,2786.598,5148.22412,1923.840,
4069.74390,2786.598,5148.31592,1922.840,
4069.83545,2786.598,5148.40723,1922.840,
4069.92700,2786.598,5148.49902,1922.840,
4070.01855,2786.598,5148.59033,1921.840,
4070.11011,2786.598,5148.68213,1921.840,
4070.20166,2786.598,5148.77344,1921.840,
4070.29321,2786.598,5148.86475,1920.840,
4070.38477,2785.598,5148.95654,1920.840,
4070.47607,2785.598,5149.04785,1920.840,
4070.56763,2785.598,5149.13965,1920.840,
4070.65918,2785.598,5149.23096,1919.840,
4070.75073,2785.598,5149.32275,1919.840,
4070.84229,2785.598,5149.41406,1919.840,
4070.93384,2784.598,5149.50586,1919.840,
4071.02539,2784.598,5149.59717,1918.840,
4071.11670,2784.598,5149.68848,1918.840,
4071.20825,2783.598,5149.78027,1917.840,
4071.29980,2784.598,5149.87158,1917.840,
4071.39136,2784.598,5149.96338,1917.840,
4071.48291,2784.598,5150.05469,1917.840,
4071.57446,2783.598,5150.14648,1916.840,
4071.66602,2783.598,5150.23779,1916.840,
4071.75757,2783.598,5150.32910,1915.840,
4071.84888,2783.598,5150.42090,1915.840,
4071.94043,2782.598,5150.51221,1915.840,
4072.03198,2783.598,5150.60400,1915.840,
4072.12354,2782.598,5150.69531,1914.840,
4072.21509,2782.598,5150.78711,1913.840,
4072.30664,2783.598,5150.87842,1913.840,
4072.39819,2782.598,5150.96973,1913.840,
4072.48975,2782.598,5151.06152,1913.840,
4072.58105,2781.598,5151.15283,1913.840,
4072.67261,2782.598,5151.24463,1913.840,
4072.76416,2781.598,5151.33594,1912.840,
4072.85571,2781.598,5151.42773,1912.840,
4072.94727,2781.598,5151.51904,1911.840,
4073.03882,2781.598,5151.61084,1912.840,
4073.13037,2781.598,5151.70215,1912.840,
4073.22168,2782.598,5151.79346,1912.840,
4073.31323,2781.598,5151.88525,1912.840,
4073.40479,2781.598,5151.97656,1913.840,
4073.49634,2781.598,5152.06836,1913.840,
4073.58789,2781.598,5152.15967,1912.840,
4073.67944,2780.598,5152.25146,1913.840,
4073.77100,2780.598,5152.34277,1912.840,
4073.86255,2780.598,5152.43408,1912.840,
4073.95386,2780.598,5152.52588,1911.840,
4074.04541,2780.598,5152.61719,1910.840,
4074.13696,2780.598,5152.70898,1910.840,
4074.22852,2779.598,5152.80029,1909.840,
4074.32007,2779.598,5152.89209,1909.840,
4074.41162,2779.598,5152.98340,1909.840,
4074.50317,2779.598,5153.07471,1908.840,
4074.59448,2779.598,5153.16650,1907.840,
4074.68604,2779.598,5153.25781,1907.840,
4074.77759,2779.598,5153.34961,1906.840,
4074.86914,2779.598,5153.44092,1906.840,
4074.96069,2779.598,5153.53271,1905.840,
4075.05225,2778.598,5153.62402,1905.840,
4075.14380,2778.598,5153.71582,1904.840,
4075.23535,2778.598,5153.80713,1904.840,
4075.32666,2778.598,5153.89844,1904.840,
4075.41821,2778.598,5153.99023,1903.840,
4075.50977,2778.598,5154.08154,1903.840,
4075.60132,2777.598,5154.17334,1903.840,
4075.69287,2777.598,5154.26465,1903.840,
4075.78442,2777.598,5154.35645,1903.840,
4075.87598,2777.598,5154.44775,1904.840,
4075.96753,2777.598,5154.53906,1903.840,
4076.05884,2777.598,5154.63086,1903.840,
4076.15039,2777.598,5154.72217,1903.840,
4076.24194,2776.598,5154.81396,1903.840,
4076.33350,2776.598,5154.90527,1903.840,
4076.42505,2777.598,5154.99707,1902.840,
4076.51660,2777.598,5155.08838,1902.840,
4076.60815,2776.598,5155.17969,1902.840,
4076.69946,2776.598,5155.27148,1901.840,
4076.79102,2776.598,5155.36279,1901.840,
4076.88257,2776.598,5155.45459,1901.840,
4076.97412,2776.598,5155.54590,1900.840,
4077.06567,2775.598,5155.63770,1899.840,
4077.15723,2775.598,5155.72900,1899.840,
4077.24878,2775.598,5155.82080,1898.840,
4077.34033,2775.598,5155.91211,1898.840,
4077.43164,2775.598,5156.00342,1897.840,
4077.52319,2775.598,5156.09521,1896.840,
4077.61475,2775.598,5156.18652,1896.840,
4077.70630,2775.598,5156.27832,1896.840,
4077.79785,2775.598,5156.36963,1895.840,
4077.88940,2775.598,5156.46143,1895.840,
4077.98096,2775.598,5156.55273,1894.840,
4078.07251,2776.598,5156.64404,1894.840,
4078.16382,2776.598,5156.73584,1893.840,
4078.25537,2776.598,5156.82715,1894.840,
4078.34692,2776.598,5156.91895,1893.840,
4078.43848,2777.598,5157.01025,1893.840,
4078.53003,2777.598,5157.10205,1892.840,
4078.62158,2776.598,5157.19336,1892.840,
4078.71313,2776.598,5157.28467,1892.840,
4078.80444,2776.598,5157.37646,1891.840,
4078.89600,2775.598,5157.46777,1891.840,
4078.98755,2775.598,5157.55957,1890.840,
4079.07910,2775.598,5157.65088,1890.840,
4079.17065,2774.598,5157.74268,1890.840,
4079.26221,2774.598,5157.83398,1890.840,
4079.35376,2773.598,5157.92529,1889.840,
4079.44531,2773.598,5158.01709,1889.840,
4079.53662,2773.598,5158.10840,1889.840,
4079.62817,2773.598,5158.20020,1888.840,
4079.71973,2772.598,5158.29150,1889.840,
4079.81128,2772.598,5158.38330,1888.840,
4079.90283,2772.598,5158.47461,1887.840,
4079.99438,2772.598,5158.56641,1888.840,
4080.08594,2771.598,5158.65771,1887.840,
4080.17749,2771.598,5158.74902,1886.840,
4080.26880,2770.598,5158.84082,1886.840,
4080.36035,2770.598,5158.93213,1886.840,
4080.45190,2769.598,5159.02393,1885.840,
4080.54346,2769.598,5159.11523,1885.840,
4080.63501,2768.598,5159.20703,1885.840,
4080.72656,2769.598,5159.29834,1885.840,
4080.81812,2769.598,5159.38965,1884.840,
4080.90942,2768.598,5159.48145,1885.840,
4081.00098,2769.598,5159.57275,1884.840,
4081.09253,2769.598,5159.66455,1883.840,
4081.18408,2769.598,5159.75586,1883.840,
4081.27563,2769.598,5159.84766,1883.840,
4081.36719,2769.598,5159.93896,1883.840,
4081.45874,2769.598,5160.03027,1882.840,
4081.55029,2769.598,5160.12207,1882.840,
4081.64160,2769.598,5160.21338,1882.840,
4081.73315,2769.598,5160.30518,1881.840,
4081.82471,2768.598,5160.39648,1882.840,
4081.91626,2769.598,5160.48828,1881.840,
4082.00781,2769.598,5160.57959,1881.840,
4082.09937,2769.598,5160.67139,1880.840,
4082.19092,2768.598,5160.76270,1880.840,
4082.28223,2768.598,5160.85400,1879.840,
4082.37378,2768.598,5160.94580,1879.840,
4082.46533,2767.598,5161.03711,1879.840,
4082.55688,2767.598,5161.12891,1879.840,
4082.64844,2767.598,5161.22021,1879.840,
4082.73999,2767.598,5161.31201,1878.840,
4082.83154,2766.598,5161.40332,1878.840,
4082.92310,2767.598,5161.49463,1877.840,
4083.01440,2767.598,5161.58643,1877.840,
4083.10596,2767.598,5161.67773,1877.840,
4083.19751,2766.598,5161.76953,1876.840,
4083.28906,2766.598,5161.86084,1876.840,
4083.38062,2766.598,5161.95264,1876.840,
4083.47217,2767.598,5162.04395,1875.840,
4083.56372,2766.598,5162.13525,1875.840,
4083.65527,2766.598,5162.22705,1874.840,
4083.74658,2765.598,5162.31836,1873.840,
4083.83813,2766.598,5162.41016,1874.840,
4083.92969,2765.598,5162.50146,1873.840,
4084.02124,2766.598,5162.59326,1873.840,
4084.11279,2765.598,5162.68457,1873.840,
4084.20435,2765.598,5162.77637,1872.840,
4084.29590,2765.598,5162.86768,1872.840,
4084.38721,2764.598,5162.95898,1872.840,
4084.47876,2764.598,5163.05078,1871.840,
4084.57031,2764.598,5163.14209,1872.840,
4084.66187,2764.598,5163.23389,1871.840,
4084.75342,2764.598,5163.32520,1871.840,
4084.84497,2764.598,5163.41699,1871.840,
4084.93652,2764.598,5163.50830,1870.840,
4085.02808,2763.598,5163.59961,1870.840,
4085.11938,2763.598,5163.69141,1870.840,
4085.21094,2763.598,5163.78271,1869.840,
4085.30249,2763.598,5163.87451,1869.840,
4085.39404,2763.598,5163.96582,1868.840,
4085.48560,2763.598,5164.05762,1869.840,
4085.57715,2762.598,5164.14893,1869.840,
4085.66870,2763.598,5164.24023,1868.840,
4085.76025,2762.598,5164.33203,1868.840,
4085.85156,2762.598,5164.42334,1867.840,
4085.94312,2762.598,5164.51514,1867.840,
4086.03467,2762.598,5164.60645,1867.840,
4086.12622,2762.598,5164.69824,1866.840,
4086.21777,2761.598,5164.78955,1866.840,
4086.30933,2761.598,5164.88135,1866.840,
4086.40088,2762.598,5164.97266,1865.840,
4086.49219,2761.598,5165.06396,1865.840,
4086.58374,2761.598,5165.15576,1864.840,
4086.67529,2761.598,5165.24707,1865.840,
4086.76685,2761.598,5165.33887,1864.840,
4086.85840,2761.598,5165.43018,1863.840,
4086.94995,2760.598,5165.52197,1863.840,
4087.04150,2760.598,5165.61328,1864.840,
4087.13306,2760.598,5165.70459,1862.840,
4087.22437,2760.598,5165.79639,1862.840,
4087.31592,2760.598,5165.88770,1862.840,
4087.40747,2760.598,5165.97949,1862.840,
4087.49902,2760.598,5166.07080,1862.840,
4087.59058,2760.598,5166.16260,1861.840,
4087.68213,2759.598,5166.25391,1861.840,
4087.77368,2759.598,5166.34521,1860.840,
4087.86499,2760.598,5166.43701,1860.840,
4087.95654,2759.598,5166.52832,1859.840,
4088.04810,2759.598,5166.62012,1859.840,
4088.13965,2758.598,5166.71143,1859.840,
4088.23120,2758.598,5166.80322,1859.840,
4088.32275,2758.598,5166.89453,1858.840,
4088.41431,2758.598,5166.98633,1858.840,
4088.50586,2758.598,5167.07764,1858.840,
4088.59717,2758.598,5167.16895,1857.840,
4088.68872,2758.598,5167.26074,1857.840,
4088.78027,2758.598,5167.35205,1857.840,
4088.87183,2757.598,5167.44385,1857.840,
4088.96338,2758.598,5167.53516,1856.840,
4089.05493,2757.598,5167.62695,1855.840,
4089.14648,2758.598,5167.71826,1855.840,
4089.23804,2756.598,5167.80957,1855.840,
4089.32935,2757.598,5167.90137,1855.840,
4089.42090,2757.598,5167.99268,1855.840,
4089.51245,2756.598,5168.08447,1854.840,
4089.60400,2757.598,5168.17578,1854.840,
4089.69556,2756.598,5168.26758,1854.840,
4089.78711,2756.598,5168.35889,1853.840,
4089.87866,2756.598,5168.45020,1853.840,
4089.96997,2756.598,5168.54199,1854.840,
4090.06152,2756.598,5168.63330,1853.840,
4090.15308,2755.598,5168.72510,1852.840,
4090.24463,2755.598,5168.81641,1852.840,
4090.33618,2755.598,5168.90820,1852.840,
4090.42773,2755.598,5168.99951,1851.840,
4090.51929,2755.598,5169.09082,1851.840,
4090.61084,2755.598,5169.18262,1851.840,
4090.70215,2755.598,5169.27393,1851.840,
4090.79370,2755.598,5169.36572,1850.840,
4090.88525,2754.598,5169.45703,1851.840,
4090.97681,2754.598,5169.54883,1851.840,
4091.06836,2754.598,5169.64014,1851.840,
4091.15991,2754.598,5169.73193,1851.840,
4091.25146,2754.598,5169.82324,1851.840,
4091.34302,2754.598,5169.91455,1851.840,
4091.43433,2753.598,5170.00635,1852.840,
4091.52588,2753.598,5170.09766,1851.840,
4091.61743,2753.598,5170.18945,1850.840,
4091.70898,2753.598,5170.28076,1850.840,
4091.80054,2753.598,5170.37256,1850.840,
4091.89209,2752.598,5170.46387,1849.840,
4091.98364,2753.598,5170.55518,1849.840,
4092.07495,2753.598,5170.64697,1848.840,
4092.16650,2753.598,5170.73828,1848.840,
4092.25806,2753.598,5170.83008,1847.840,
4092.34961,2752.598,5170.92139,1846.840,
4092.44116,2752.598,5171.01318,1846.840,
4092.53271,2752.598,5171.10449,1845.840,
4092.62427,2752.598,5171.19580,1844.840,
4092.71582,2752.598,5171.28760,1844.840,
4092.80713,2751.598,5171.37891,1843.840,
4092.89868,2751.598,5171.47070,1843.840,
4092.99023,2751.598,5171.56201,1843.840,
4093.08179,2751.598,5171.65381,1842.840,
4093.17334,2750.598,5171.74512,1842.840,
4093.26489,2750.598,5171.83691,1841.840,
4093.35645,2750.598,5171.92822,1841.840,
4093.44775,2751.598,5172.01953,1841.840,
4093.53931,2750.598,5172.11133,1841.840,
4093.63086,2750.598,5172.20264,1841.840,
4093.72241,2751.598,5172.29443,1840.840,
4093.81396,2750.598,5172.38574,1841.840,
4093.90552,2750.598,5172.47754,1840.840,
4093.99707,2750.598,5172.56885,1840.840,
4094.08862,2750.598,5172.66016,1840.840,
4094.17993,2749.598,5172.75195,1840.840,
4094.27148,2749.598,5172.84326,1839.840,
4094.36304,2749.598,5172.93506,1840.840,
4094.45459,2749.598,5173.02637,1838.840,
4094.54614,2749.598,5173.11816,1839.840,
4094.63770,2748.598,5173.20947,1838.840,
4094.72925,2748.598,5173.30078,1838.840,
4094.82080,2748.598,5173.39258,1838.840,
4094.91211,2748.598,5173.48389,1837.840,
4095.00366,2747.598,5173.57568,1837.840,
4095.09521,2747.598,5173.66699,1837.840,
4095.18677,2748.598,5173.75879,1836.840,
4095.27832,2747.598,5173.85010,1835.840,
4095.36987,2747.598,5173.94189,1835.840,
4095.46143,2747.598,5174.03320,1835.840,
4095.55273,2747.598,5174.12451,1834.840,
4095.64429,2746.598,5174.21631,1834.840,
4095.73584,2746.598,5174.30762,1833.840,
4095.82739,2746.598,5174.39941,1834.840,
4095.91895,2746.598,5174.49072,1833.840,
4096.01025,2746.598,5174.58252,1832.840,
4096.10205,2746.598,5174.67383,1831.840,
4096.19336,2745.598,5174.76514,1832.840,
4096.28516,2745.598,5174.85693,1831.840,
4096.37646,2745.598,5174.94824,1831.840,
4096.46826,2745.598,5175.04004,1830.840,
4096.55957,2744.598,5175.13135,1830.840,
4096.65088,2744.598,5175.22314,1829.840,
4096.74268,2743.598,5175.31445,1829.840,
4096.83398,2742.598,5175.40576,1829.840,
4096.92578,2741.598,5175.49756,1829.840,
4097.01709,2741.598,5175.58887,1828.840,
4097.10889,2740.598,5175.68066,1828.840,
4097.20020,2741.598,5175.77197,1828.840,
4097.29150,2740.598,5175.86377,1829.840,
4097.38330,2740.598,5175.95508,1827.840,
4097.47461,2741.598,5176.04688,1827.840,
4097.56641,2740.598,5176.13818,1826.840,
4097.65771,2740.598,5176.22949,1827.840,
4097.74951,2740.598,5176.32129,1826.840,
4097.84082,2740.598,5176.41260,1826.840,
4097.93262,2740.598,5176.50439,1825.840,
4098.02393,2740.598,5176.59570,1826.840,
4098.11523,2742.598,5176.68750,1825.840,
4098.20703,2741.598,5176.77881,1825.840,
4098.29834,2741.598,5176.87012,1824.840,
4098.39014,2741.598,5176.96191,1824.840,
4098.48145,2741.598,5177.05322,1823.840,
4098.57324,2741.598,5177.14502,1823.840,
4098.66455,2741.598,5177.23633,1823.840,
4098.75586,2741.598,5177.32813,1823.840,
4098.84766,2741.598,5177.41943,1822.840,
4098.93896,2741.598,5177.51074,1822.840,
4099.03076,2742.598,5177.60254,1822.840,
4099.12207,2743.598,5177.69385,1821.840,
4099.21387,2743.598,5177.78564,1821.840,
4099.30518,2743.598,5177.87695,1821.840,
4099.39648,2744.598,5177.96875,1821.840,
4099.48828,2743.598,5178.06006,1820.840,
4099.57959,2743.598,5178.15186,1820.840,
4099.67139,2743.598,5178.24316,1819.840,
4099.76270,2742.598,5178.33447,1819.840,
4099.85449,2741.598,5178.42627,1819.840,
4099.94580,2741.598,5178.51758,1819.840,
4100.03760,2741.598,5178.60938,1818.840,
4100.12891,2741.598,5178.70068,1818.840,
4100.22021,2740.598,5178.79248,1818.840,
4100.31201,2740.598,5178.88379,1817.840,
4100.40332,2739.598,5178.97510,1817.840,
4100.49512,2739.598,5179.06689,1817.840,
4100.58643,2739.598,5179.15820,1817.840,
4100.67822,2738.598,5179.25000,1816.840,
4100.76953,2738.598,5179.34131,1816.840,
4100.86084,2738.598,5179.43311,1815.840,
4100.95264,2737.598,5179.52441,1815.840,
4101.04395,2738.598,5179.61572,1815.840,
4101.13574,2737.598,5179.70752,1814.840,
4101.22705,2737.598,5179.79883,1814.840,
4101.31885,2737.598,5179.89063,1814.840,
4101.41016,2737.598,5179.98193,1813.840,
4101.50146,2737.598,5180.07373,1813.840,
4101.59326,2737.598,5180.16504,1813.840,
4101.68457,2737.598,5180.25684,1813.840,
4101.77637,2736.598,5180.34814,1812.840,
4101.86768,2736.598,5180.43945,1812.840,
4101.95947,2736.598,5180.53125,1812.840,
4102.05078,2736.598,5180.62256,1811.840,
4102.14258,2736.598,5180.71436,1811.840,
4102.23389,2736.598,5180.80566,1811.840,
4102.32520,2735.598,5180.89746,1811.840,
4102.41699,2735.598,5180.98877,1809.840,
4102.50830,2736.598,5181.08008,1810.840,
4102.60010,2735.598,5181.17188,1809.840,
4102.69141,2735.598,5181.26318,1809.840,
4102.78320,2735.598,5181.35498,1808.840,
4102.87451,2735.598,5181.44629,1808.840,
4102.96582,2734.598,5181.53809,1808.840,
4103.05762,2734.598,5181.62939,1808.840,
4103.14893,2734.598,5181.72070,1808.840,
4103.24072,2734.598,5181.81250,1807.840,
4103.33203,2733.598,5181.90381,1807.840,
4103.42383,2733.598,5181.99561,1807.840,
4103.51514,2733.598,5182.08691,1806.840,
4103.60645,2733.598,5182.17871,1806.840,
4103.69824,2733.598,5182.27002,1805.840,
4103.78955,2733.598,5182.36133,1805.840,
4103.88135,2733.598,5182.45313,1805.840,
4103.97266,2733.598,5182.54443,1805.840,
4104.06445,2733.598,5182.63623,1805.840,
4104.15576,2732.598,5182.72754,1804.840,
4104.24756,2732.598,5182.81934,1803.840,
4104.33887,2731.598,5182.91064,1804.840,
4104.43018,2732.598,5183.00244,1803.840,
4104.52197,2731.598,5183.09375,1803.840,
4104.61328,2731.598,5183.18506,1803.840,
4104.70508,2732.598,5183.27686,1803.840,
4104.79639,2731.598,5183.36816,1802.840,
4104.88818,2731.598,5183.45996,1802.840,
4104.97949,2731.598,5183.55127,1801.840,
4105.07080,2730.598,5183.64307,1801.840,
4105.16260,2730.598,5183.73438,1801.840,
4105.25391,2730.598,5183.82568,1801.840,
4105.34570,2730.598,5183.91748,1800.840,
4105.43701,2730.598,5184.00879,1799.840,
4105.52881,2730.598,5184.10059,1799.840,
4105.62012,2730.598,5184.19189,1799.840,
4105.71143,2729.598,5184.28369,1799.840,
4105.80322,2729.598,5184.37500,1799.840,
4105.89453,2729.598,5184.46631,1798.840,
4105.98633,2729.598,5184.55811,1797.840,
4106.07764,2729.598,5184.64941,1798.840,
4106.16943,2729.598,5184.74121,1797.840,
4106.26074,2728.598,5184.83252,1797.840,
4106.35254,2728.598,5184.92432,1796.840,
4106.44385,2728.598,5185.01563,1797.840,
4106.53516,2728.598,5185.10742,1796.840,
4106.62695,2728.598,5185.19873,1796.840,
4106.71826,2728.598,5185.29004,1795.840,
4106.81006,2728.598,5185.38184,1795.840,
4106.90137,2728.598,5185.47314,1794.840,
4106.99316,2727.598,5185.56494,1795.840,
4107.08447,2727.598,5185.65625,1794.840,
4107.17578,2727.598,5185.74805,1794.840,
4107.26758,2727.598,5185.83936,1794.840,
4107.35889,2727.598,5185.93066,1793.840,
4107.45068,2727.598,5186.02246,1793.840,
4107.54199,2726.598,5186.11377,1793.840,
4107.63379,2727.598,5186.20557,1793.840,
4107.72510,2726.598,5186.29688,1792.840,
4107.81641,2726.598,5186.38867,1791.840,
4107.90820,2725.598,5186.47998,1791.840,
4107.99951,2725.598,5186.57129,1791.840,
4108.09131,2725.598,5186.66309,1791.840,
4108.18262,2725.598,5186.75439,1790.840,
4108.27441,2725.598,5186.84619,1791.840,
4108.36572,2725.598,5186.93750,1790.840,
4108.45752,2725.598,5187.02930,1790.840,
4108.54883,2724.598,5187.12061,1790.840,
4108.64014,2724.598,5187.21240,1790.840,
4108.73193,2724.598,5187.30371,1790.840,
4108.82324,2724.598,5187.39502,1790.840,
4108.91504,2724.598,5187.48682,1790.840,
4109.00635,2723.598,5187.57813,1790.840,
4109.09814,2724.598,5187.66992,1789.840,
4109.18945,2723.598,5187.76123,1789.840,
4109.28076,2723.598,5187.85303,1788.840,
4109.37256,2723.598,5187.94434,1788.840,
4109.46387,2723.598,5188.03564,1788.840,
4109.55566,2722.598,5188.12744,1787.840,
4109.64697,2722.598,5188.21875,1787.840,
4109.73877,2722.598,5188.31055,1785.840,
4109.83008,2722.598,5188.40186,1785.840,
4109.92139,2722.598,5188.49365,1785.840,
4110.01318,2722.598,5188.58496,1785.840,
4110.10449,2721.598,5188.67627,1784.840,
4110.19629,2721.598,5188.76807,1783.840,
4110.28760,2721.598,5188.85938,1783.840,
4110.37939,2721.598,5188.95117,1783.840,
4110.47070,2721.598,5189.04248,1783.840,
4110.56201,2721.598,5189.13428,1782.840,
4110.65381,2721.598,5189.22559,1781.840,
4110.74512,2721.598,5189.31738,1780.840,
4110.83691,2720.598,5189.40869,1780.840,
4110.92822,2720.598,5189.50000,1781.840,
4111.02002,2720.598,5189.59180,1780.840,
4111.11133,2719.598,5189.68311,1780.840,
4111.20313,2720.598,5189.77490,1780.840,
4111.29443,2720.598,5189.86621,1780.840,
4111.38574,2719.598,5189.95801,1780.840,
4111.47754,2719.598,5190.04932,1780.840,
4111.56885,2719.598,5190.14063,1781.840,
4111.66064,2719.598,5190.23242,1780.840,
4111.75195,2718.598,5190.32373,1780.840,
4111.84375,2719.598,5190.41553,1779.840,
4111.93506,2718.598,5190.50684,1780.840,
4112.02637,2717.598,5190.59863,1779.840,
4112.11816,2718.598,5190.68994,1779.840,
4112.20947,2718.598,5190.78125,1778.840,
4112.30127,2718.598,5190.87305,1777.840,
4112.39258,2717.598,5190.96436,1777.840,
4112.48438,2717.598,5191.05615,1777.840,
4112.57568,2717.598,5191.14746,1776.840,
4112.66699,2717.598,5191.23926,1776.840,
4112.75879,2717.598,5191.33057,1775.840,
4112.85010,2717.598,5191.42236,1774.840,
4112.94189,2717.598,5191.51367,1774.840,
4113.03320,2716.598,5191.60498,1773.840,
4113.12500,2717.598,5191.69678,1773.840,
4113.21631,2716.598,5191.78809,1772.840,
4113.30811,2716.598,5191.87988,1772.840,
4113.39941,2715.598,5191.97119,1772.840,
4113.49072,2715.598,5192.06299,1772.840,
4113.58252,2716.598,5192.15430,1771.840,
4113.67383,2716.598,5192.24561,1771.840,
4113.76563,2715.598,5192.33740,1771.840,
4113.85693,2715.598,5192.42871,1770.840,
4113.94873,2714.598,5192.52051,1770.840,
4114.04004,2715.598,5192.61182,1770.840,
4114.13135,2714.598,5192.70361,1769.840,
4114.22314,2715.598,5192.79492,1769.840,
4114.31445,2714.598,5192.88623,1768.840,
4114.40625,2713.598,5192.97803,1768.840,
4114.49756,2714.598,5193.06934,1768.840,
4114.58936,2714.598,5193.16113,1768.840,
4114.68066,2714.598,5193.25244,1767.840,
4114.77197,2714.598,5193.34424,1767.840,
4114.86377,2714.598,5193.43555,1768.840,
4114.95508,2713.598,5193.52734,1767.840,
4115.04688,2713.598,5193.61865,1767.840,
4115.13818,2713.598,5193.70996,1766.840,
4115.22998,2712.598,5193.80176,1766.840,
4115.32129,2713.598,5193.89307,1765.840,
4115.41309,2713.598,5193.98486,1765.840,
4115.50439,2713.598,5194.07617,1765.840,
4115.59570,2713.598,5194.16797,1764.840,
4115.68750,2714.598,5194.25928,1764.840,
4115.77881,2712.598,5194.35059,1763.840,
4115.87061,2713.598,5194.44238,1763.840,
4115.96191,2713.598,5194.53369,1763.840,
4116.05371,2712.598,5194.62549,1763.840,
4116.14502,2712.598,5194.71680,1762.840,
4116.23633,2712.598,5194.80859,1762.840,
4116.32813,2711.598,5194.89990,1762.840,
4116.41943,2711.598,5194.99121,1761.840,
4116.51123,2710.598,5195.08301,1761.840,
4116.60254,2710.598,5195.17432,1760.840,
4116.69434,2710.598,5195.26611,1760.840,
4116.78564,2710.598,5195.35742,1760.840,
4116.87695,2709.598,5195.44922,1759.840,
4116.96875,2709.598,5195.54053,1759.840,
4117.06006,2709.598,5195.63184,1759.840,
4117.15186,2710.598,5195.72363,1759.840,
4117.24316,2709.598,5195.81494,1759.840,
4117.33496,2708.598,5195.90674,1758.840,
4117.42627,2709.598,5195.99805,1758.840,
4117.51807,2708.598,5196.08984,1758.840,
4117.60938,2708.598,5196.18115,1757.840,
4117.70068,2708.598,5196.27295,1757.840,
4117.79248,2708.598,5196.36426,1757.840,
4117.88379,2709.598,5196.45557,1757.840,
4117.97559,2709.598,5196.54736,1756.840,
4118.06689,2709.598,5196.63867,1756.840,
4118.15869,2709.598,5196.73047,1756.840,
4118.25000,2708.598,5196.82178,1755.840,
4118.34131,2709.598,5196.91357,1755.840,
4118.43311,2708.598,5197.00488,1755.840,
4118.52441,2708.598,5197.09619,1755.840,
4118.61621,2708.598,5197.18799,1754.840,
4118.70752,2708.598,5197.27930,1753.840,
4118.79932,2707.598,5197.37109,1753.840,
4118.89063,2707.598,5197.46240,1753.840,
4118.98193,2707.598,5197.55420,1753.840,
4119.07373,2706.598,5197.64551,1753.840,
4119.16504,2706.598,5197.73682,1751.840,
4119.25684,2706.598,5197.82861,1752.840,
4119.34814,2705.598,5197.91992,1752.840,
4119.43994,2705.598,5198.01172,1751.840,
4119.53125,2705.598,5198.10303,1751.840,
4119.62305,2704.598,5198.19482,1751.840,
4119.71436,2705.598,5198.28613,1750.840,
4119.80566,2704.598,5198.37793,1750.840,
4119.89746,2704.598,5198.46924,1749.840,
4119.98877,2704.598,5198.56055,1749.840,
4120.08057,2704.598,5198.65234,1749.840,
4120.17188,2703.598,5198.74365,1748.840,
4120.26367,2703.598,5198.83545,1748.840,
4120.35498,2703.598,5198.92676,1748.840,
4120.44629,2703.598,5199.01855,1747.840,
4120.53809,2703.598,5199.10986,1747.840,
4120.62939,2703.598,5199.20117,1747.840,
4120.72119,2702.598,5199.29297,1748.840,
4120.81250,2702.598,5199.38428,1747.840,
4120.90430,2702.598,5199.47607,1746.840,
4120.99561,2702.598,5199.56738,1745.840,
4121.08691,2702.598,5199.65918,1746.840,
4121.17871,2701.598,5199.75049,1745.840,
4121.27002,2701.598,5199.84180,1745.840,
4121.36182,2701.598,5199.93359,1745.840,
4121.45313,2701.598,5200.02490,1745.840,
4121.54492,2702.598,5200.11670,1744.840,
4121.63623,2701.598,5200.20801,1743.840,
4121.72754,2700.598,5200.29980,1742.840,
4121.81934,2701.598,5200.39111,1743.840,
4121.91064,2700.598,5200.48291,1742.840,
4122.00244,2700.598,5200.57422,1742.840,
4122.09375,2700.598,5200.66553,1742.840,
4122.18555,2700.598,5200.75732,1742.840,
4122.27686,2700.598,5200.84863,1741.840,
4122.36865,2700.598,5200.94043,1742.840,
4122.45996,2699.598,5201.03174,1741.840,
4122.55127,2699.598,5201.12354,1740.840,
4122.64307,2698.598,5201.21484,1740.840,
4122.73438,2698.598,5201.30615,1740.840,
4122.82617,2698.598,5201.39795,1740.840,
4122.91748,2699.598,5201.48926,1739.840,
4123.00928,2699.598,5201.58105,1739.840,
4123.10059,2698.598,5201.67236,1738.840,
4123.19189,2698.598,5201.76416,1738.840,
4123.28369,2697.598,5201.85547,1738.840,
4123.37500,2698.598,5201.94678,1738.840,
4123.46680,2698.598,5202.03857,1737.840,
4123.55811,2697.598,5202.12988,1737.840,
4123.64990,2697.598,5202.22168,1737.840,
4123.74121,2697.598,5202.31299,1736.840,
4123.83252,2696.598,5202.40479,1736.840,
4123.92432,2697.598,5202.49609,1735.840,
4124.01563,2696.598,5202.58789,1735.840,
4124.10742,2696.598,5202.67920,1735.840,
4124.19873,2696.598,5202.77051,1734.840,
4124.29053,2696.598,5202.86230,1734.840,
4124.38184,2696.598,5202.95361,1734.840,
4124.47363,2696.598,5203.04541,1734.840,
4124.56494,2695.598,5203.13672,1733.840,
4124.65625,2695.598,5203.22852,1732.840,
4124.74805,2695.598,5203.31982,1733.840,
4124.83936,2695.598,5203.41113,1732.840,
4124.93115,2694.598,5203.50293,1732.840,
4125.02246,2694.598,5203.59424,1732.840,
4125.11426,2694.598,5203.68604,1732.840,
4125.20557,2695.598,5203.77734,1731.840,
4125.29688,2694.598,5203.86914,1731.840,
4125.38867,2695.598,5203.96045,1731.840,
4125.47998,2694.598,5204.05176,1731.840,
4125.57178,2693.598,5204.14355,1729.840,
4125.66309,2694.598,5204.23486,1729.840,
4125.75488,2694.598,5204.32666,1729.840,
4125.84619,2694.598,5204.41797,1728.840,
4125.93750,2693.598,5204.50977,1728.840,
4126.02930,2693.598,5204.60107,1727.840,
4126.12061,2693.598,5204.69287,1725.840,
4126.21240,2693.598,5204.78418,1725.840,
4126.30371,2693.598,5204.87549,1725.840,
4126.39551,2692.598,5204.96729,1724.840,
4126.48682,2692.598,5205.05859,1724.840,
4126.57861,2692.598,5205.15039,1724.840,
4126.66992,2691.598,5205.24170,1723.840,
4126.76123,2692.598,5205.33350,1724.840,
4126.85303,2691.598,5205.42480,1723.840,
4126.94434,2691.598,5205.51611,1723.840,
4127.03613,2691.598,5205.60791,1723.840,
4127.12744,2690.598,5205.69922,1723.840,
4127.21924,2691.598,5205.79102,1724.840,
4127.31055,2690.598,5205.88232,1723.840,
4127.40186,2690.598,5205.97412,1723.840,
4127.49365,2690.598,5206.06543,1723.840,
4127.58496,2690.598,5206.15674,1722.840,
4127.67676,2690.598,5206.24854,1722.840,
4127.76807,2689.598,5206.33984,1722.840,
4127.85986,2689.598,5206.43164,1722.840,
4127.95117,2689.598,5206.52295,1722.840,
4128.04248,2689.598,5206.61475,1723.840,
4128.13428,2689.598,5206.70605,1722.840,
4128.22559,2689.598,5206.79736,1721.840,
4128.31738,2688.598,5206.88916,1722.840,
4128.40869,2688.598,5206.98047,1722.840,
4128.50049,2688.598,5207.07227,1722.840,
4128.59180,2688.598,5207.16357,1721.840,
4128.68359,2687.598,5207.25537,1720.840,
4128.77490,2687.598,5207.34668,1720.840,
4128.86621,2688.598,5207.43848,1719.840,
4128.95801,2687.598,5207.52979,1718.840,
4129.04932,2687.598,5207.62109,1717.840,
4129.14111,2686.598,5207.71289,1717.840,
4129.23242,2686.598,5207.80420,1717.840,
4129.32422,2687.598,5207.89600,1716.840,
4129.41553,2686.598,5207.98730,1715.840,
4129.50684,2686.598,5208.07910,1716.840,
4129.59863,2685.598,5208.17041,1715.840,
4129.68994,2686.598,5208.26172,1715.840,
4129.78174,2685.598,5208.35352,1714.840,
4129.87305,2685.598,5208.44482,1714.840,
4129.96484,2685.598,5208.53662,1714.840,
4130.05615,2684.598,5208.62793,1713.840,
4130.14746,2685.598,5208.71973,1713.840,
4130.23926,2684.598,5208.81104,1713.840,
4130.33057,2685.598,5208.90234,1713.840,
4130.42236,2684.598,5208.99414,1713.840,
4130.51367,2684.598,5209.08545,1712.840,
4130.60547,2684.598,5209.17725,1712.840,
4130.69678,2683.598,5209.26855,1711.840,
4130.78857,2684.598,5209.36035,1711.840,
4130.87988,2683.598,5209.45166,1711.840,
4130.97119,2683.598,5209.54346,1712.840,
4131.06299,2683.598,5209.63477,1711.840,
4131.15430,2682.598,5209.72607,1710.840,
4131.24609,2682.598,5209.81787,1710.840,
4131.33740,2682.598,5209.90918,1710.840,
4131.42920,2682.598,5210.00098,1709.840,
4131.52051,2682.598,5210.09229,1709.840,
4131.61182,2682.598,5210.18408,1709.840,
4131.70361,2681.598,5210.27539,1709.840,
4131.79492,2682.598,5210.36670,1708.840,
4131.88672,2681.598,5210.45850,1708.840,
4131.97803,2681.598,5210.54980,1708.840,
4132.06982,2681.598,5210.64160,1707.840,
4132.16113,2680.598,5210.73291,1707.840,
4132.25244,2680.598,5210.82471,1707.840,
4132.34424,2680.598,5210.91602,1706.840,
4132.43555,2680.598,5211.00732,1706.840,
4132.52734,2680.598,5211.09912,1706.840,
4132.61865,2679.598,5211.19043,1705.840,
4132.71045,2680.598,5211.28223,1706.840,
4132.80176,2679.598,5211.37354,1705.840,
4132.89355,2679.598,5211.46533,1705.840,
4132.98486,2679.598,5211.55664,1704.840,
4133.07617,2678.598,5211.64844,1704.840,
4133.16797,2678.598,5211.73975,1704.840,
4133.25928,2679.598,5211.83105,1704.840,
4133.35107,2677.598,5211.92285,1703.840,
4133.44238,2677.598,5212.01416,1703.840,
4133.53418,2677.598,5212.10596,1702.840,
4133.62549,2676.598,5212.19727,1702.840,
4133.71680,2675.598,5212.28906,1702.840,
4133.80859,2675.598,5212.38037,1701.840,
4133.89990,2674.598,5212.47168,1701.840,
4133.99170,2674.598,5212.56348,1700.840,
4134.08301,2674.598,5212.65479,1700.840,
4134.17480,2674.598,5212.74658,1700.840,
4134.26611,2674.598,5212.83789,1700.840,
4134.35742,2674.598,5212.92969,1700.840,
4134.44922,2674.598,5213.02100,1700.840,
4134.54053,2674.598,5213.11230,1699.840,
4134.63232,2674.598,5213.20410,1699.840,
4134.72363,2674.598,5213.29541,1699.840,
4134.81543,2674.598,5213.38721,1698.840,
4134.90674,2674.598,5213.47852,1698.840,
4134.99805,2674.598,5213.57031,1698.840,
4135.08984,2675.598,5213.66162,1697.840,
4135.18115,2674.598,5213.75342,1697.840,
4135.27295,2674.598,5213.84473,1697.840,
4135.36426,2674.598,5213.93604,1697.840,
4135.45605,2674.598,5214.02783,1696.840,
4135.54736,2674.598,5214.11914,1695.840,
4135.63916,2674.598,5214.21094,1695.840,
4135.73047,2673.598,5214.30225,1695.840,
4135.82178,2673.598,5214.39404,1695.840,
4135.91357,2672.598,5214.48535,1694.840,
4136.00488,2671.598,5214.57666,1694.840,
4136.09668,2670.598,5214.66846,1693.840,
4136.18799,2670.598,5214.75977,1693.840,
4136.27979,2670.598,5214.85156,1693.840,
4136.37109,2669.598,5214.94287,1692.840,
4136.46240,2669.598,5215.03467,1693.840,
4136.55420,2669.598,5215.12598,1692.840,
4136.64551,2669.598,5215.21729,1692.840,
4136.73730,2669.598,5215.30908,1692.840,
4136.82861,2669.598,5215.40039,1692.840,
4136.92041,2669.598,5215.49219,1691.840,
4137.01172,2669.598,5215.58350,1691.840,
4137.10303,2669.598,5215.67529,1690.840,
4137.19482,2669.598,5215.76660,1690.840,
4137.28613,2669.598,5215.85840,1690.840,
4137.37793,2669.598,5215.94971,1689.840,
4137.46924,2669.598,5216.04102,1689.840,
4137.56104,2669.598,5216.13281,1688.840,
4137.65234,2670.598,5216.22412,1689.840,
4137.74414,2669.598,5216.31592,1688.840,
4137.83545,2669.598,5216.40723,1687.840,
4137.92676,2669.598,5216.49902,1688.840,
4138.01855,2669.598,5216.59033,1687.840,
4138.10986,2669.598,5216.68164,1687.840,
4138.20166,2668.598,5216.77344,1686.840,
4138.29297,2669.598,5216.86475,1687.840,
4138.38477,2668.598,5216.95654,1686.840,
4138.47607,2668.598,5217.04785,1685.840,
4138.56738,2668.598,5217.13965,1686.840,
4138.65918,2667.598,5217.23096,1685.840,
4138.75049,2667.598,5217.32227,1684.840,
4138.84229,2667.598,5217.41406,1685.840,
4138.93359,2667.598,5217.50537,1684.840,
4139.02539,2666.598,5217.59717,1683.840,
4139.11670,2667.598,5217.68848,1683.840,
4139.20801,2667.598,5217.78027,1683.840,
4139.29980,2666.598,5217.87158,1682.840,
4139.39111,2667.598,5217.96338,1682.840,
4139.48291,2666.598,5218.05469,1682.840,
4139.57422,2666.598,5218.14600,1682.840,
4139.66602,2666.598,5218.23779,1681.840,
4139.75732,2666.598,5218.32910,1682.840,
4139.84912,2665.598,5218.42090,1681.840,
4139.94043,2665.598,5218.51221,1680.840,
4140.03174,2665.598,5218.60400,1680.840,
4140.12354,2665.598,5218.69531,1680.840,
4140.21484,2665.598,5218.78662,1680.840,
4140.30664,2665.598,5218.87842,1679.840,
4140.39795,2665.598,5218.96973,1679.840,
4140.48975,2665.598,5219.06152,1678.840,
4140.58105,2665.598,5219.15283,1678.840,
4140.67236,2664.598,5219.24463,1678.840,
4140.76416,2664.598,5219.33594,1677.840,
4140.85547,2663.598,5219.42725,1677.840,
4140.94727,2663.598,5219.51904,1677.840,
4141.03857,2663.598,5219.61035,1677.840,
4141.13037,2663.598,5219.70215,1676.840,
4141.22168,2663.598,5219.79346,1676.840,
4141.31299,2663.598,5219.88525,1676.840,
4141.40479,2663.598,5219.97656,1676.840,
4141.49609,2663.598,5220.06787,1675.840,
4141.58789,2662.598,5220.15967,1675.840,
4141.67920,2662.598,5220.25098,1674.840,
4141.77100,2661.598,5220.34277,1674.840,
4141.86230,2662.598,5220.43408,1674.840,
4141.95410,2661.598,5220.52588,1674.840,
4142.04541,2662.598,5220.61719,1673.840,
4142.13672,2661.598,5220.70898,1673.840,
4142.22852,2661.598,5220.80029,1672.840,
4142.31982,2661.598,5220.89160,1672.840,
4142.41162,2661.598,5220.98340,1672.840,
4142.50293,2660.598,5221.07471,1671.840,
4142.59473,2660.598,5221.16650,1671.840,
4142.68604,2660.598,5221.25781,1671.840,
4142.77734,2660.598,5221.34961,1671.840,
4142.86914,2659.598,5221.44092,1670.840,
4142.96045,2659.598,5221.53223,1669.840,
4143.05225,2658.598,5221.62402,1669.840,
4143.14355,2659.598,5221.71533,1669.840,
4143.23535,2658.598,5221.80713,1669.840,
4143.32666,2658.598,5221.89844,1669.840,
4143.41797,2658.598,5221.99023,1670.840,
4143.50977,2658.598,5222.08154,1669.840,
4143.60107,2658.598,5222.17285,1669.840,
4143.69287,2658.598,5222.26465,1669.840,
4143.78418,2658.598,5222.35596,1669.840,
4143.87598,2658.598,5222.44775,1669.840,
4143.96729,2657.598,5222.53906,1669.840,
4144.05908,2657.598,5222.63086,1668.840,
4144.15039,2657.598,5222.72217,1668.840,
4144.24170,2657.598,5222.81396,1667.840,
4144.33350,2656.598,5222.90527,1667.840,
4144.42480,2657.598,5222.99658,1666.840,
4144.51660,2656.598,5223.08838,1666.840,
4144.60791,2656.598,5223.17969,1666.840,
4144.69971,2656.598,5223.27148,1665.840,
4144.79102,2656.598,5223.36279,1664.840,
4144.88232,2655.598,5223.45459,1664.840,
4144.97412,2656.598,5223.54590,1663.840,
4145.06543,2655.598,5223.63721,1663.840,
4145.15723,2655.598,5223.72900,1662.840,
4145.24854,2655.598,5223.82031,1663.840,
4145.34033,2655.598,5223.91211,1662.840,
4145.43164,2655.598,5224.00342,1662.840,
4145.52295,2654.598,5224.09521,1661.840,
4145.61475,2654.598,5224.18652,1661.840,
4145.70605,2654.598,5224.27783,1660.840,
4145.79785,2653.598,5224.36963,1661.840,
4145.88916,2653.598,5224.46094,1660.840,
4145.98096,2653.598,5224.55273,1660.840,
4146.07227,2653.598,5224.64404,1660.840,
4146.16357,2652.598,5224.73584,1660.840,
4146.25537,2652.598,5224.82715,1660.840,
4146.34668,2652.598,5224.91895,1660.840,
4146.43848,2653.598,5225.01025,1660.840,
4146.52979,2652.598,5225.10156,1659.840,
4146.62158,2652.598,5225.19336,1659.840,
4146.71289,2652.598,5225.28467,1659.840,
4146.80469,2652.598,5225.37646,1659.840,
4146.89600,2652.598,5225.46777,1658.840,
4146.98730,2651.598,5225.55957,1658.840,
4147.07910,2652.598,5225.65088,1658.840,
4147.17041,2651.598,5225.74219,1657.840,
4147.26221,2651.598,5225.83398,1657.840,
4147.35352,2651.598,5225.92529,1657.840,
4147.44531,2651.598,5226.01709,1656.840,
4147.53662,2650.598,5226.10840,1655.840,
4147.62793,2650.598,5226.20020,1655.840,
4147.71973,2650.598,5226.29150,1654.840,
4147.81104,2650.598,5226.38281,1654.840,
4147.90283,2650.598,5226.47461,1653.840,
4147.99414,2649.598,5226.56592,1653.840,
4148.08594,2649.598,5226.65771,1652.840,
4148.17725,2649.598,5226.74902,1652.840,
4148.26855,2648.598,5226.84082,1651.840,
4148.36035,2648.598,5226.93213,1651.840,
4148.45166,2649.598,5227.02393,1651.840,
4148.54346,2648.598,5227.11523,1651.840,
4148.63477,2648.598,5227.20654,1650.840,
4148.72656,2648.598,5227.29834,1650.840,
4148.81787,2647.598,5227.38965,1650.840,
4148.90967,2647.598,5227.48145,1649.840,
4149.00098,2647.598,5227.57275,1648.840,
4149.09229,2647.598,5227.66455,1649.840,
4149.18408,2647.598,5227.75586,1649.840,
4149.27539,2647.598,5227.84717,1648.840,
4149.36719,2647.598,5227.93896,1648.840,
4149.45850,2646.598,5228.03027,1648.840,
4149.55029,2646.598,5228.12207,1647.840,
4149.64160,2646.598,5228.21338,1647.840,
4149.73291,2646.598,5228.30518,1647.840,
4149.82471,2646.598,5228.39648,1646.840,
4149.91602,2646.598,5228.48779,1646.840,
4150.00781,2645.598,5228.57959,1646.840,
4150.09912,2645.598,5228.67090,1646.840,
4150.19092,2645.598,5228.76270,1645.840,
4150.28223,2645.598,5228.85400,1644.840,
4150.37354,2644.598,5228.94580,1645.840,
4150.46533,2644.598,5229.03711,1644.840,
4150.55664,2644.598,5229.12891,1644.840,
4150.64844,2643.598,5229.22021,1644.840,
4150.73975,2643.598,5229.31152,1643.840,
4150.83154,2644.598,5229.40332,1643.840,
4150.92285,2643.598,5229.49463,1643.840,
4151.01465,2643.598,5229.58643,1642.840,
4151.10596,2643.598,5229.67773,1641.840,
4151.19727,2643.598,5229.76953,1641.840,
4151.28906,2643.598,5229.86084,1641.840,
4151.38037,2643.598,5229.95215,1641.840,
4151.47217,2643.598,5230.04395,1641.840,
4151.56348,2642.598,5230.13525,1640.840,
4151.65527,2643.598,5230.22705,1640.840,
4151.74658,2642.598,5230.31836,1640.840,
4151.83789,2642.598,5230.41016,1640.840,
4151.92969,2643.598,5230.50146,1639.840,
4152.02100,2642.598,5230.59277,1639.840,
4152.11279,2642.598,5230.68457,1639.840,
4152.20410,2642.598,5230.77588,1638.840,
4152.29590,2642.598,5230.86768,1638.840,
4152.38721,2641.598,5230.95898,1638.840,
4152.47852,2641.598,5231.05078,1637.840,
4152.57031,2641.598,5231.14209,1637.840,
4152.66162,2640.598,5231.23340,1636.840,
4152.75342,2640.598,5231.32520,1636.840,
4152.84473,2639.598,5231.41650,1636.840,
4152.93652,2640.598,5231.50830,1637.840,
4153.02783,2639.598,5231.59961,1636.840,
4153.11963,2639.598,5231.69141,1635.840,
4153.21094,2639.598,5231.78271,1634.840,
4153.30225,2639.598,5231.87451,1634.840,
4153.39404,2638.598,5231.96582,1634.840,
4153.48535,2638.598,5232.05713,1634.840,
4153.57715,2638.598,5232.14893,1633.840,
4153.66846,2638.598,5232.24023,1633.840,
4153.76025,2638.598,5232.33203,1632.840,
4153.85156,2637.598,5232.42334,1632.840,
4153.94287,2638.598,5232.51514,1632.840,
4154.03467,2638.598,5232.60645,1631.840,
4154.12598,2638.598,5232.69775,1631.840,
4154.21777,2638.598,5232.78955,1631.840,
4154.30908,2638.598,5232.88086,1630.840,
4154.40088,2637.598,5232.97266,1631.840,
4154.49219,2637.598,5233.06396,1630.840,
4154.58350,2636.598,5233.15576,1630.840,
4154.67529,2636.598,5233.24707,1630.840,
4154.76660,2635.598,5233.33838,1629.840,
4154.85840,2635.598,5233.43018,1629.840,
4154.94971,2635.598,5233.52148,1628.840,
4155.04150,2635.598,5233.61328,1628.840,
4155.13281,2634.598,5233.70459,1627.840,
4155.22461,2635.598,5233.79639,1627.840,
4155.31592,2634.598,5233.88770,1627.840,
4155.40723,2634.598,5233.97949,1627.840,
4155.49902,2634.598,5234.07080,1627.840,
4155.59033,2633.598,5234.16211,1626.840,
4155.68213,2633.598,5234.25391,1626.840,
4155.77344,2634.598,5234.34521,1625.840,
4155.86523,2633.598,5234.43701,1626.840,
4155.95654,2632.598,5234.52832,1625.840,
4156.04785,2632.598,5234.62012,1625.840,
4156.13965,2633.598,5234.71143,1624.840,
4156.23096,2632.598,5234.80273,1624.840,
4156.32275,2632.598,5234.89453,1624.840,
4156.41406,2632.598,5234.98584,1624.840,
4156.50586,2632.598,5235.07764,1623.840,
4156.59717,2631.598,5235.16895,1623.840,
4156.68848,2632.598,5235.26074,1622.840,
4156.78027,2631.598,5235.35205,1622.840,
4156.87158,2631.598,5235.44336,1622.840,
4156.96338,2631.598,5235.53516,1621.840,
4157.05469,2630.598,5235.62646,1621.840,
4157.14648,2630.598,5235.71826,1621.840,
4157.23779,2630.598,5235.80957,1621.840,
4157.32959,2630.598,5235.90137,1621.840,
4157.42090,2630.598,5235.99268,1620.840,
4157.51221,2630.598,5236.08447,1620.840,
4157.60400,2630.598,5236.17578,1620.840,
4157.69531,2629.598,5236.26709,1619.840,
4157.78711,2629.598,5236.35889,1619.840,
4157.87842,2629.598,5236.45020,1619.840,
4157.97021,2629.598,5236.54199,1618.840,
4158.06152,2628.598,5236.63330,1618.840,
4158.15283,2629.598,5236.72510,1618.840,
4158.24463,2628.598,5236.81641,1617.840,
4158.33594,2628.598,5236.90771,1617.840,
4158.42773,2628.598,5236.99951,1617.840,
4158.51904,2628.598,5237.09082,1616.840,
4158.61084,2628.598,5237.18262,1615.840,
4158.70215,2628.598,5237.27393,1616.840,
4158.79346,2628.598,5237.36572,1616.840,
4158.88525,2627.598,5237.45703,1615.840,
4158.97656,2627.598,5237.54834,1615.840,
4159.06836,2627.598,5237.64014,1614.840,
4159.15967,2627.598,5237.73145,1614.840,
4159.25146,2626.598,5237.82324,1614.840,
4159.34277,2626.598,5237.91455,1614.840,
4159.43408,2626.598,5238.00635,1614.840,
4159.52588,2626.598,5238.09766,1613.840,
4159.61719,2626.598,5238.18945,1613.840,
4159.70898,2626.598,5238.28076,1612.840,
4159.80029,2625.598,5238.37207,1612.840,
4159.89209,2625.598,5238.46387,1612.840,
4159.98340,2625.598,5238.55518,1612.840,
4160.07520,2625.598,5238.64697,1611.840,
4160.16650,2624.598,5238.73828,1611.840,
4160.25781,2624.598,5238.83008,1611.840,
4160.34961,2625.598,5238.92139,1611.840,
4160.44092,2624.598,5239.01270,1610.840,
4160.53271,2623.598,5239.10449,1610.840,
4160.62402,2624.598,5239.19580,1610.840,
4160.71582,2623.598,5239.28760,1609.840,
4160.80713,2623.598,5239.37891,1609.840,
4160.89844,2622.598,5239.47070,1609.840,
4160.99023,2622.598,5239.56201,1608.840,
4161.08154,2623.598,5239.65332,1607.840,
4161.17334,2622.598,5239.74512,1606.840,
4161.26465,2623.598,5239.83643,1606.840,
4161.35645,2622.598,5239.92822,1606.840,
4161.44775,2621.598,5240.01953,1605.840,
4161.53906,2622.598,5240.11133,1604.840,
4161.63086,2621.598,5240.20264,1604.840,
4161.72217,2622.598,5240.29443,1605.840,
4161.81396,2621.598,5240.38574,1604.840,
4161.90527,2621.598,5240.47705,1603.840,
4161.99707,2621.598,5240.56885,1604.840,
4162.08838,2621.598,5240.66016,1604.840,
4162.18018,2620.598,5240.75195,1603.840,
4162.27148,2620.598,5240.84326,1603.840,
4162.36279,2620.598,5240.93506,1603.840,
4162.45459,2620.598,5241.02637,1602.840,
4162.54590,2620.598,5241.11768,1602.840,
4162.63770,2620.598,5241.20947,1603.840,
4162.72900,2619.598,5241.30078,1602.840,
4162.82080,2619.598,5241.39258,1602.840,
4162.91211,2619.598,5241.48389,1602.840,
4163.00342,2619.598,5241.57568,1601.840,
4163.09521,2618.598,5241.66699,1601.840,
4163.18652,2618.598,5241.75830,1601.840,
4163.27832,2618.598,5241.85010,1601.840,
4163.36963,2618.598,5241.94141,1600.840,
4163.46143,2617.598,5242.03320,1600.840,
4163.55273,2618.598,5242.12451,1600.840,
4163.64404,2617.598,5242.21631,1600.840,
4163.73584,2617.598,5242.30762,1599.840,
4163.82715,2617.598,5242.39941,1599.840,
4163.91895,2617.598,5242.49072,1598.840,
4164.01025,2617.598,5242.58203,1597.840,
4164.10205,2616.598,5242.67383,1596.840,
4164.19336,2616.598,5242.76514,1596.840,
4164.28516,2616.598,5242.85693,1596.840,
4164.37646,2616.598,5242.94824,1595.840,
4164.46777,2615.598,5243.04004,1595.840,
4164.55957,2615.598,5243.13135,1595.840,
4164.65088,2614.598,5243.22266,1595.840,
4164.74268,2615.598,5243.31445,1594.840,
4164.83398,2614.598,5243.40576,1594.840,
4164.92578,2614.598,5243.49756,1594.840,
4165.01709,2614.598,5243.58887,1593.840,
4165.10840,2613.598,5243.68066,1593.840,
4165.20020,2614.598,5243.77197,1593.840,
4165.29150,2614.598,5243.86328,1593.840,
4165.38330,2613.598,5243.95508,1593.840,
4165.47461,2614.598,5244.04639,1592.840,
4165.56641,2613.598,5244.13818,1592.840,
4165.65771,2613.598,5244.22949,1592.840,
4165.74902,2612.598,5244.32129,1592.840,
4165.84082,2612.598,5244.41260,1591.840,
4165.93213,2612.598,5244.50391,1591.840,
4166.02393,2612.598,5244.59570,1591.840,
4166.11523,2612.598,5244.68701,1591.840,
4166.20703,2612.598,5244.77881,1590.840,
4166.29834,2611.598,5244.87012,1591.840,
4166.39014,2612.598,5244.96191,1590.840,
4166.48145,2611.598,5245.05322,1589.840,
4166.57275,2611.598,5245.14502,1589.840,
4166.66455,2611.598,5245.23633,1589.840,
4166.75586,2610.598,5245.32764,1589.840,
4166.84766,2610.598,5245.41943,1588.840,
4166.93896,2611.598,5245.51074,1588.840,
4167.03076,2610.598,5245.60254,1587.840,
4167.12207,2610.598,5245.69385,1587.840,
4167.21338,2610.598,5245.78564,1587.840,
4167.30518,2609.598,5245.87695,1587.840,
4167.39648,2609.598,5245.96826,1586.840,
4167.48828,2609.598,5246.06006,1586.840,
4167.57959,2609.598,5246.15137,1586.840,
4167.67139,2608.598,5246.24316,1585.840,
4167.76270,2609.598,5246.33447,1585.840,
4167.85400,2608.598,5246.42627,1585.840,
4167.94580,2608.598,5246.51758,1585.840,
4168.03711,2608.598,5246.60889,1585.840,
4168.12891,2608.598,5246.70068,1584.840,
4168.22021,2607.598,5246.79199,1584.840,
4168.31201,2607.598,5246.88379,1583.840,
4168.40332,2608.598,5246.97510,1583.840,
4168.49512,2607.598,5247.06689,1583.840,
4168.58643,2607.598,5247.15820,1583.840,
4168.67773,2607.598,5247.25000,1582.840,
4168.76953,2607.598,5247.34131,1582.840,
4168.86084,2606.598,5247.43262,1581.840,
4168.95264,2606.598,5247.52441,1581.840,
4169.04395,2605.598,5247.61572,1582.840,
4169.13574,2605.598,5247.70752,1581.840,
4169.22705,2605.598,5247.79883,1581.840,
4169.31836,2605.598,5247.89063,1580.840,
4169.41016,2604.598,5247.98193,1580.840,
4169.50146,2604.598,5248.07324,1579.840,
4169.59326,2603.598,5248.16504,1580.840,
4169.68457,2603.598,5248.25635,1579.840,
4169.77637,2603.598,5248.34814,1578.840,
4169.86768,2603.598,5248.43945,1578.840,
4169.95898,2602.598,5248.53125,1578.840,
4170.05078,2603.598,5248.62256,1577.840,
4170.14209,2603.598,5248.71387,1577.840,
4170.23389,2602.598,5248.80566,1577.840,
4170.32520,2602.598,5248.89697,1576.840,
4170.41699,2602.598,5248.98877,1576.840,
4170.50830,2602.598,5249.08008,1577.840,
4170.60010,2602.598,5249.17188,1576.840,
4170.69141,2601.598,5249.26318,1575.840,
4170.78271,2601.598,5249.35498,1575.840,
4170.87451,2601.598,5249.44629,1575.840,
4170.96582,2601.598,5249.53760,1574.840,
4171.05762,2601.598,5249.62939,1574.840,
4171.14893,2601.598,5249.72070,1573.840,
4171.24072,2601.598,5249.81250,1573.840,
4171.33203,2601.598,5249.90381,1573.840,
4171.42334,2600.598,5249.99561,1573.840,
4171.51514,2601.598,5250.08691,1572.840,
4171.60645,2600.598,5250.17822,1572.840,
4171.69824,2600.598,5250.27002,1572.840,
4171.78955,2600.598,5250.36133,1571.840,
4171.88135,2600.598,5250.45313,1571.840,
4171.97266,2600.598,5250.54443,1572.840,
4172.06396,2600.598,5250.63623,1571.840,
4172.15576,2600.598,5250.72754,1570.840,
4172.24707,2601.598,5250.81885,1571.840,
4172.33887,2600.598,5250.91064,1570.840,
4172.43018,2601.598,5251.00195,1570.840,
4172.52197,2600.598,5251.09375,1569.840,
4172.61328,2599.598,5251.18506,1569.840,
4172.70459,2599.598,5251.27686,1569.840,
4172.79639,2599.598,5251.36816,1568.840,
4172.88770,2598.598,5251.45996,1568.840,
4172.97949,2597.598,5251.55127,1567.840,
4173.07080,2598.598,5251.64258,1567.840,
4173.16260,2597.598,5251.73438,1567.840,
4173.25391,2597.598,5251.82568,1567.840,
4173.34570,2596.598,5251.91748,1566.840,
4173.43701,2597.598,5252.00879,1567.840,
4173.52832,2595.598,5252.10059,1566.840,
4173.62012,2596.598,5252.19189,1565.840,
4173.71143,2595.598,5252.28320,1565.840,
4173.80322,2595.598,5252.37500,1565.840,
4173.89453,2595.598,5252.46631,1564.840,
4173.98633,2594.598,5252.55811,1565.840,
4174.07764,2595.598,5252.64941,1564.840,
4174.16895,2594.598,5252.74121,1564.840,
4174.26074,2595.598,5252.83252,1563.840,
4174.35205,2594.598,5252.92383,1563.840,
4174.44385,2594.598,5253.01563,1563.840,
4174.53516,2594.598,5253.10693,1562.840,
4174.62695,2593.598,5253.19873,1562.840,
4174.71826,2593.598,5253.29004,1562.840,
4174.80957,2594.598,5253.38184,1562.840,
4174.90137,2593.598,5253.47314,1562.840,
4174.99268,2593.598,5253.56494,1561.840,
4175.08447,2592.598,5253.65625,1561.840,
4175.17578,2592.598,5253.74756,1560.840,
4175.26758,2592.598,5253.83936,1560.840,
4175.35889,2592.598,5253.93066,1560.840,
4175.45068,2592.598,5254.02246,1560.840,
4175.54199,2591.598,5254.11377,1559.840,
4175.63330,2591.598,5254.20557,1559.840,
4175.72510,2591.598,5254.29688,1559.840,
4175.81641,2591.598,5254.38818,1558.840,
4175.90820,2591.598,5254.47998,1558.840,
4175.99951,2591.598,5254.57129,1557.840,
4176.09131,2590.598,5254.66309,1557.840,
4176.18262,2591.598,5254.75439,1557.840,
4176.27393,2590.598,5254.84619,1556.840,
4176.36572,2590.598,5254.93750,1557.840,
4176.45703,2589.598,5255.02881,1556.840,
4176.54883,2589.598,5255.12061,1556.840,
4176.64014,2589.598,5255.21191,1555.840,
4176.73193,2589.598,5255.30371,1554.840,
4176.82324,2589.598,5255.39502,1555.840,
4176.91455,2589.598,5255.48682,1554.840,
4177.00635,2588.598,5255.57813,1553.840,
4177.09766,2588.598,5255.66992,1554.840,
4177.18945,2589.598,5255.76123,1553.840,
4177.28076,2588.598,5255.85254,1553.840,
4177.37256,2588.598,5255.94434,1553.840,
4177.46387,2588.598,5256.03564,1552.840,
4177.55566,2587.598,5256.12744,1552.840,
4177.64697,2586.598,5256.21875,1552.840,
4177.73828,2586.598,5256.31055,1552.840,
4177.83008,2586.598,5256.40186,1552.840,
4177.92139,2586.598,5256.49316,1551.840,
4178.01318,2586.598,5256.58496,1550.840,
4178.10449,2585.598,5256.67627,1551.840,
4178.19629,2585.598,5256.76807,1551.840,
4178.28760,2585.598,5256.85938,1551.840,
4178.37891,2585.598,5256.95117,1552.840,
4178.47070,2585.598,5257.04248,1552.840,
4178.56201,2584.598,5257.13379,1552.840,
4178.65381,2584.598,5257.22559,1552.840,
4178.74512,2584.598,5257.31689,1551.840,
4178.83691,2584.598,5257.40869,1551.840,
4178.92822,2584.598,5257.50000,1551.840,
4179.01953,2584.598,5257.59180,1550.840,
4179.11133,2584.598,5257.68311,1550.840,
4179.20264,2583.598,5257.77441,1550.840,
4179.29443,2583.598,5257.86621,1550.840,
4179.38574,2583.598,5257.95752,1548.840,
4179.47754,2583.598,5258.04932,1548.840,
4179.56885,2583.598,5258.14063,1548.840,
4179.66064,2582.598,5258.23242,1547.840,
4179.75195,2582.598,5258.32373,1546.840,
4179.84326,2582.598,5258.41553,1546.840,
4179.93506,2582.598,5258.50684,1545.840,
4180.02637,2581.598,5258.59814,1545.840,
4180.11816,2582.598,5258.68994,1544.840,
4180.20947,2581.598,5258.78125,1543.840,
4180.30127,2581.598,5258.87305,1544.840,
4180.39258,2581.598,5258.96436,1543.840,
4180.48389,2580.598,5259.05615,1543.840,
4180.57568,2580.598,5259.14746,1541.840,
4180.66699,2580.598,5259.23877,1540.840,
4180.75879,2580.598,5259.33057,1540.840,
4180.85010,2580.598,5259.42188,1539.840,
4180.94189,2579.598,5259.51367,1538.840,
4181.03320,2579.598,5259.60498,1538.840,
4181.12451,2579.598,5259.69678,1538.840,
4181.21631,2579.598,5259.78809,1538.840,
4181.30762,2579.598,5259.87939,1537.840,
4181.39941,2579.598,5259.97119,1536.840,
4181.49072,2578.598,5260.06250,1537.840,
4181.58252,2579.598,5260.15430,1536.840,
4181.67383,2578.598,5260.24561,1537.840,
4181.76563,2578.598,5260.33740,1536.840,
4181.85693,2577.598,5260.42871,1536.840,
4181.94824,2577.598,5260.52051,1536.840,
4182.04004,2577.598,5260.61182,1536.840,
4182.13135,2576.598,5260.70313,1536.840,
4182.22314,2577.598,5260.79492,1537.840,
4182.31445,2577.598,5260.88623,1535.840,
4182.40625,2576.598,5260.97803,1536.840,
4182.49756,2575.598,5261.06934,1535.840,
4182.58887,2576.598,5261.16113,1535.840,
4182.68066,2575.598,5261.25244,1535.840,
4182.77197,2575.598,5261.34375,1535.840,
4182.86377,2574.598,5261.43555,1535.840,
4182.95508,2574.598,5261.52686,1534.840,
4183.04688,2575.598,5261.61865,1534.840,
4183.13818,2574.598,5261.70996,1533.840,
4183.22949,2574.598,5261.80176,1533.840,
4183.32129,2574.598,5261.89307,1532.840,
4183.41260,2574.598,5261.98438,1533.840,
4183.50439,2573.598,5262.07617,1532.840,
4183.59570,2573.598,5262.16748,1531.840,
4183.68750,2573.598,5262.25928,1532.840,
4183.77881,2573.598,5262.35059,1531.840,
4183.87012,2573.598,5262.44238,1531.840,
4183.96191,2572.598,5262.53369,1531.840,
4184.05322,2572.598,5262.62549,1530.840,
4184.14502,2572.598,5262.71680,1530.840,
4184.23633,2572.598,5262.80811,1529.840,
4184.32813,2571.598,5262.89990,1530.840,
4184.41943,2572.598,5262.99121,1529.840,
4184.51123,2571.598,5263.08301,1528.840,
4184.60254,2571.598,5263.17432,1528.840,
4184.69385,2571.598,5263.26611,1528.840,
4184.78564,2570.598,5263.35742,1527.840,
4184.87695,2571.598,5263.44873,1527.840,
4184.96875,2570.598,5263.54053,1527.840,
4185.06006,2570.598,5263.63184,1526.840,
4185.15186,2570.598,5263.72363,1527.840,
4185.24316,2570.598,5263.81494,1526.840,
4185.33447,2569.598,5263.90674,1526.840,
4185.42627,2569.598,5263.99805,1526.840,
4185.51758,2569.598,5264.08936,1525.840,
4185.60938,2569.598,5264.18115,1525.840,
4185.70068,2568.598,5264.27246,1525.840,
4185.79248,2568.598,5264.36426,1525.840,
4185.88379,2568.598,5264.45557,1524.840,
4185.97510,2569.598,5264.54736,1523.840,
4186.06689,2567.598,5264.63867,1524.840,
4186.15820,2568.598,5264.73047,1524.840,
4186.25000,2567.598,5264.82178,1523.840,
4186.34131,2567.598,5264.91309,1522.840,
4186.43311,2567.598,5265.00488,1522.840,
4186.52441,2567.598,5265.09619,1522.840,
4186.61621,2566.598,5265.18799,1522.840,
4186.70752,2566.598,5265.27930,1522.840,
4186.79883,2565.598,5265.37109,1521.840,
4186.89063,2565.598,5265.46240,1521.840,
4186.98193,2565.598,5265.55371,1520.840,
4187.07373,2566.598,5265.64551,1521.840,
4187.16504,2565.598,5265.73682,1520.840,
4187.25684,2565.598,5265.82861,1519.840,
4187.34814,2565.598,5265.91992,1519.840,
4187.43945,2565.598,5266.01172,1519.840,
4187.53125,2564.598,5266.10303,1518.840,
4187.62256,2564.598,5266.19434,1518.840,
4187.71436,2564.598,5266.28613,1517.840,
4187.80566,2563.598,5266.37744,1517.840,
4187.89746,2562.598,5266.46924,1517.840,
4187.98877,2562.598,5266.56055,1517.840,
4188.08008,2561.598,5266.65234,1517.840,
4188.17188,2560.598,5266.74365,1516.840,
4188.26318,2560.598,5266.83545,1517.840,
4188.35498,2559.598,5266.92676,1516.840,
4188.44629,2559.598,5267.01807,1516.840,
4188.53809,2559.598,5267.10986,1515.840,
4188.62939,2558.598,5267.20117,1514.840,
4188.72119,2559.598,5267.29297,1515.840,
4188.81250,2558.598,5267.38428,1514.840,
4188.90381,2559.598,5267.47607,1514.840,
4188.99561,2558.598,5267.56738,1513.840,
4189.08691,2559.598,5267.65869,1513.840,
4189.17871,2559.598,5267.75049,1513.840,
4189.27002,2559.598,5267.84180,1513.840,
4189.36182,2559.598,5267.93359,1512.840,
4189.45313,2559.598,5268.02490,1512.840,
4189.54443,2558.598,5268.11670,1512.840,
4189.63623,2559.598,5268.20801,1512.840,
4189.72754,2558.598,5268.29932,1511.840,
4189.81934,2558.598,5268.39111,1510.840,
4189.91064,2558.598,5268.48242,1510.840,
4190.00244,2558.598,5268.57422,1511.840,
4190.09375,2558.598,5268.66553,1510.840,
4190.18506,2558.598,5268.75732,1509.840,
4190.27686,2559.598,5268.84863,1509.840,
4190.36816,2559.598,5268.93994,1509.840,
4190.45996,2559.598,5269.03174,1508.840,
4190.55127,2558.598,5269.12305,1508.840,
4190.64307,2559.598,5269.21484,1508.840,
4190.73438,2558.598,5269.30615,1508.840,
4190.82617,2558.598,5269.39795,1508.840,
4190.91748,2558.598,5269.48926,1507.840,
4191.00879,2557.598,5269.58105,1508.840,
4191.10059,2557.598,5269.67236,1507.840,
4191.19189,2556.598,5269.76367,1506.840,
4191.28369,2556.598,5269.85547,1506.840,
4191.37500,2555.598,5269.94678,1506.840,
4191.46680,2555.598,5270.03857,1505.840,
4191.55811,2555.598,5270.12988,1505.840,
4191.64941,2554.598,5270.22168,1505.840,
4191.74121,2554.598,5270.31299,1505.840,
4191.83252,2554.598,5270.40430,1504.840,
4191.92432,2553.598,5270.49609,1504.840,
4192.01563,2553.598,5270.58740,1504.840,
4192.10742,2554.598,5270.67920,1504.840,
4192.19873,2553.598,5270.77051,1504.840,
4192.29004,2553.598,5270.86230,1503.840,
4192.38184,2552.598,5270.95361,1503.840,
4192.47314,2552.598,5271.04492,1502.840,
4192.56494,2552.598,5271.13672,1502.840,
4192.65625,2552.598,5271.22803,1502.840,
4192.74805,2551.598,5271.31982,1501.840,
4192.83936,2552.598,5271.41113,1501.840,
4192.93115,2551.598,5271.50293,1501.840,
4193.02246,2551.598,5271.59424,1500.840,
4193.11377,2551.598,5271.68604,1500.840,
4193.20557,2550.598,5271.77734,1500.840,
4193.29688,2551.598,5271.86865,1500.840,
4193.38867,2551.598,5271.96045,1499.840,
4193.47998,2550.598,5272.05176,1499.840,
4193.57178,2550.598,5272.14355,1499.840,
4193.66309,2550.598,5272.23486,1498.840,
4193.75439,2549.598,5272.32666,1498.840,
4193.84619,2549.598,5272.41797,1498.840,
4193.93750,2549.598,5272.50928,1499.840,
4194.02930,2549.598,5272.60107,1498.840,
4194.12061,2549.598,5272.69238,1497.840,
4194.21240,2548.598,5272.78418,1497.840,
4194.30371,2548.598,5272.87549,1496.840,
4194.39502,2548.598,5272.96729,1495.840,
4194.48682,2547.598,5273.05859,1495.840,
4194.57813,2547.598,5273.14990,1496.840,
4194.66992,2547.598,5273.24170,1495.840,
4194.76123,2547.598,5273.33301,1495.840,
4194.85303,2547.598,5273.42480,1495.840,
4194.94434,2546.598,5273.51611,1494.840,
4195.03613,2546.598,5273.60791,1494.840,
4195.12744,2546.598,5273.69922,1494.840,
4195.21875,2545.598,5273.79102,1493.840,
4195.31055,2545.598,5273.88232,1493.840,
4195.40186,2546.598,5273.97363,1494.840,
4195.49365,2545.598,5274.06543,1492.840,
4195.58496,2545.598,5274.15674,1492.840,
4195.67676,2545.598,5274.24854,1491.840,
4195.76807,2545.598,5274.33984,1491.840,
4195.85938,2545.598,5274.43164,1490.840,
4195.95117,2544.598,5274.52295,1489.840,
4196.04248,2544.598,5274.61426,1489.840,
4196.13428,2544.598,5274.70605,1488.840,
4196.22559,2544.598,5274.79736,1487.840,
4196.31738,2544.598,5274.88916,1487.840,
4196.40869,2543.598,5274.98047,1487.840,
4196.50000,2543.598,5275.07227,1487.840,
4196.59180,2543.598,5275.16357,1487.840,
4196.68311,2543.598,5275.25488,1487.840,
4196.77490,2543.598,5275.34668,1487.840,
4196.86621,2542.598,5275.43799,1487.840,
4196.95801,2542.598,5275.52979,1487.840,
4197.04932,2541.598,5275.62109,1486.840,
4197.14063,2541.598,5275.71289,1486.840,
4197.23242,2541.598,5275.80420,1486.840,
4197.32373,2541.598,5275.89600,1486.840,
4197.41553,2541.598,5275.98730,1485.840,
4197.50684,2541.598,5276.07861,1486.840,
4197.59863,2541.598,5276.17041,1485.840,
4197.68994,2540.598,5276.26172,1486.840,
4197.78174,2540.598,5276.35352,1485.840,
4197.87305,2539.598,5276.44482,1485.840,
4197.96436,2539.598,5276.53662,1484.840,
4198.05615,2539.598,5276.62793,1485.840,
4198.14746,2539.598,5276.71924,1485.840,
4198.23926,2539.598,5276.81104,1485.840,
4198.33057,2539.598,5276.90234,1485.840,
4198.42236,2538.598,5276.99414,1484.840,
4198.51367,2538.598,5277.08545,1484.840,
4198.60498,2538.598,5277.17725,1483.840,
4198.69678,2538.598,5277.26855,1483.840,
4198.78809,2537.598,5277.35986,1483.840,
4198.87988,2537.598,5277.45166,1482.840,
4198.97119,2538.598,5277.54297,1481.840,
4199.06299,2537.598,5277.63477,1481.840,
4199.15430,2537.598,5277.72607,1480.840,
4199.24561,2536.598,5277.81787,1480.840,
4199.33740,2536.598,5277.90918,1479.840,
4199.42871,2536.598,5278.00098,1479.840,
4199.52051,2536.598,5278.09229,1478.840,
4199.61182,2536.598,5278.18359,1478.840,
4199.70361,2536.598,5278.27539,1478.840,
4199.79492,2535.598,5278.36670,1478.840,
4199.88672,2535.598,5278.45850,1477.840,
4199.97803,2534.598,5278.54980,1477.840,
4200.06934,2534.598,5278.64160,1477.840,
4200.16113,2534.598,5278.73291,1476.840,
4200.25244,2534.598,5278.82422,1476.840,
4200.34424,2533.598,5278.91602,1476.840,
4200.43555,2533.598,5279.00732,1475.840,
4200.52734,2533.598,5279.09912,1475.840,
4200.61865,2533.598,5279.19043,1475.840,
4200.70996,2533.598,5279.28223,1474.840,
4200.80176,2532.598,5279.37354,1474.840,
4200.89307,2532.598,5279.46484,1474.840,
4200.98486,2532.598,5279.55664,1474.840,
4201.07617,2531.598,5279.64795,1473.840,
4201.16797,2531.598,5279.73975,1474.840,
4201.25928,2531.598,5279.83105,1474.840,
4201.35059,2531.598,5279.92285,1473.840,
4201.44238,2531.598,5280.01416,1473.840,
4201.53369,2531.598,5280.10596,1472.840,
4201.62549,2531.598,5280.19727,1472.840,
4201.71680,2529.598,5280.28857,1471.840,
4201.80859,2530.598,5280.38037,1471.840,
4201.89990,2530.598,5280.47168,1471.840,
4201.99170,2530.598,5280.56348,1471.840,
4202.08301,2530.598,5280.65479,1471.840,
4202.17432,2529.598,5280.74658,1470.840,
4202.26611,2529.598,5280.83789,1470.840,
4202.35742,2529.598,5280.92920,1470.840,
4202.44922,2529.598,5281.02100,1469.840,
4202.54053,2529.598,5281.11230,1469.840,
4202.63232,2528.598,5281.20410,1469.840,
4202.72363,2528.598,5281.29541,1469.840,
4202.81494,2529.598,5281.38721,1469.840,
4202.90674,2528.598,5281.47852,1468.840,
4202.99805,2527.598,5281.56982,1468.840,
4203.08984,2527.598,5281.66162,1468.840,
4203.18115,2526.598,5281.75293,1467.840,
4203.27295,2526.598,5281.84473,1467.840,
4203.36426,2526.598,5281.93604,1466.840,
4203.45557,2526.598,5282.02783,1466.840,
4203.54736,2527.598,5282.11914,1466.840,
4203.63867,2526.598,5282.21045,1465.840,
4203.73047,2526.598,5282.30225,1465.840,
4203.82178,2525.598,5282.39355,1465.840,
4203.91357,2526.598,5282.48535,1465.840,
4204.00488,2525.598,5282.57666,1465.840,
4204.09668,2525.598,5282.66846,1464.840,
4204.18799,2525.598,5282.75977,1465.840,
4204.27930,2524.598,5282.85156,1463.840,
4204.37109,2524.598,5282.94287,1463.840,
4204.46240,2524.598,5283.03418,1463.840,
4204.55420,2524.598,5283.12598,1463.840,
4204.64551,2523.598,5283.21729,1462.840,
4204.73730,2523.598,5283.30908,1462.840,
4204.82861,2523.598,5283.40039,1462.840,
4204.91992,2523.598,5283.49219,1462.840,
4205.01172,2523.598,5283.58350,1461.840,
4205.10303,2522.598,5283.67480,1461.840,
4205.19482,2522.598,5283.76660,1461.840,
4205.28613,2522.598,5283.85791,1460.840,
4205.37793,2522.598,5283.94971,1460.840,
4205.46924,2522.598,5284.04102,1459.840,
4205.56055,2522.598,5284.13281,1459.840,
4205.65234,2521.598,5284.22412,1460.840,
4205.74365,2521.598,5284.31543,1459.840,
4205.83545,2521.598,5284.40723,1459.840,
4205.92676,2520.598,5284.49854,1458.840,
4206.01855,2519.598,5284.59033,1458.840,
4206.10986,2520.598,5284.68164,1457.840,
4206.20166,2520.598,5284.77344,1457.840,
4206.29297,2520.598,5284.86475,1457.840,
4206.38428,2519.598,5284.95654,1457.840,
4206.47607,2519.598,5285.04785,1456.840,
4206.56738,2517.598,5285.13916,1456.840,
4206.65918,2517.598,5285.23096,1456.840,
4206.75049,2517.598,5285.32227,1455.840,
4206.84229,2516.598,5285.41406,1455.840,
4206.93359,2516.598,5285.50537,1455.840,
4207.02490,2516.598,5285.59717,1454.840,
4207.11670,2515.598,5285.68848,1454.840,
4207.20801,2516.598,5285.77979,1454.840,
4207.29980,2515.598,5285.87158,1454.840,
4207.39111,2515.598,5285.96289,1453.840,
4207.48291,2515.598,5286.05469,1453.840,
4207.57422,2515.598,5286.14600,1453.840,
4207.66553,2515.598,5286.23779,1453.840,
4207.75732,2515.598,5286.32910,1452.840,
4207.84863,2515.598,5286.42041,1452.840,
4207.94043,2515.598,5286.51221,1451.840,
4208.03174,2514.598,5286.60352,1451.840,
4208.12354,2515.598,5286.69531,1451.840,
4208.21484,2514.598,5286.78662,1451.840,
4208.30664,2514.598,5286.87842,1450.840,
4208.39795,2514.598,5286.96973,1450.840,
4208.48926,2514.598,5287.06152,1450.840,
4208.58105,2515.598,5287.15283,1450.840,
4208.67236,2514.598,5287.24414,1450.840,
4208.76416,2514.598,5287.33594,1449.840,
4208.85547,2515.598,5287.42725,1449.840,
4208.94727,2515.598,5287.51904,1449.840,
4209.03857,2516.598,5287.61035,1448.840,
4209.12988,2516.598,5287.70215,1448.840,
4209.22168,2516.598,5287.79346,1447.840,
4209.31299,2515.598,5287.88477,1447.840,
4209.40479,2516.598,5287.97656,1447.840,
4209.49609,2515.598,5288.06787,1446.840,
4209.58789,2514.598,5288.15967,1446.840,
4209.67920,2514.598,5288.25098,1446.840,
4209.77051,2513.598,5288.34277,1446.840,
4209.86230,2512.598,5288.43408,1445.840,
4209.95361,2512.598,5288.52539,1445.840,
4210.04541,2512.598,5288.61719,1445.840,
4210.13672,2512.598,5288.70850,1444.840,
4210.22852,2511.598,5288.80029,1444.840,
4210.31982,2510.598,5288.89160,1444.840,
4210.41113,2509.598,5288.98340,1444.840,
4210.50293,2509.598,5289.07471,1443.840,
4210.59424,2510.598,5289.16650,1443.840,
4210.68604,2509.598,5289.25781,1443.840,
4210.77734,2509.598,5289.34912,1443.840,
4210.86914,2509.598,5289.44092,1442.840,
4210.96045,2508.598,5289.53223,1442.840,
4211.05225,2508.598,5289.62402,1442.840,
4211.14355,2508.598,5289.71533,1441.840,
4211.23486,2507.598,5289.80713,1440.840,
4211.32666,2507.598,5289.89844,1440.840,
4211.41797,2507.598,5289.98975,1441.840,
4211.50977,2507.598,5290.08154,1441.840,
4211.60107,2506.598,5290.17285,1440.840,
4211.69287,2506.598,5290.26465,1439.840,
4211.78418,2506.598,5290.35596,1439.840,
4211.87549,2506.598,5290.44775,1439.840,
4211.96729,2506.598,5290.53906,1439.840,
4212.05859,2505.598,5290.63037,1439.840,
4212.15039,2505.598,5290.72217,1438.840,
4212.24170,2504.598,5290.81348,1438.840,
4212.33350,2505.598,5290.90527,1437.840,
4212.42480,2505.598,5290.99658,1437.840,
4212.51611,2504.598,5291.08838,1437.840,
4212.60791,2504.598,5291.17969,1437.840,
4212.69922,2504.598,5291.27148,1436.840,
4212.79102,2504.598,5291.36279,1436.840,
4212.88232,2503.598,5291.45410,1436.840,
4212.97412,2504.598,5291.54590,1436.840,
4213.06543,2502.598,5291.63721,1435.840,
4213.15723,2502.598,5291.72900,1435.840,
4213.24854,2502.598,5291.82031,1435.840,
4213.33984,2502.598,5291.91211,1434.840,
4213.43164,2502.598,5292.00342,1435.840,
4213.52295,2502.598,5292.09473,1435.840,
4213.61475,2501.598,5292.18652,1435.840,
4213.70605,2501.598,5292.27783,1434.840,
4213.79785,2501.598,5292.36963,1434.840,
4213.88916,2501.598,5292.46094,1434.840,
4213.98047,2500.598,5292.55273,1433.840,
4214.07227,2500.598,5292.64404,1432.840,
4214.16357,2500.598,5292.73535,1433.840,
4214.25537,2499.598,5292.82715,1432.840,
4214.34668,2500.598,5292.91846,1432.840,
4214.43848,2499.598,5293.01025,1432.840,
4214.52979,2499.598,5293.10156,1430.840,
4214.62109,2499.598,5293.19336,1430.840,
4214.71289,2499.598,5293.28467,1430.840,
4214.80420,2499.598,5293.37598,1429.840,
4214.89600,2498.598,5293.46777,1429.840,
4214.98730,2498.598,5293.55908,1429.840,
4215.07910,2498.598,5293.65088,1428.840,
4215.17041,2498.598,5293.74219,1428.840,
4215.26221,2498.598,5293.83398,1427.840,
4215.35352,2497.598,5293.92529,1427.840,
4215.44482,2497.598,5294.01709,1427.840,
4215.53662,2497.598,5294.10840,1427.840,
4215.62793,2497.598,5294.19971,1427.840,
4215.71973,2496.598,5294.29150,1426.840,
4215.81104,2496.598,5294.38281,1426.840,
4215.90283,2496.598,5294.47461,1427.840,
4215.99414,2495.598,5294.56592,1426.840,
4216.08545,2495.598,5294.65771,1426.840,
4216.17725,2495.598,5294.74902,1426.840,
4216.26855,2495.598,5294.84033,1426.840,
4216.36035,2495.598,5294.93213,1425.840,
4216.45166,2495.598,5295.02344,1425.840,
4216.54346,2495.598,5295.11523,1425.840,
4216.63477,2494.598,5295.20654,1425.840,
4216.72607,2494.598,5295.29834,1425.840,
4216.81787,2494.598,5295.38965,1424.840,
4216.90918,2493.598,5295.48096,1424.840,
4217.00098,2493.598,5295.57275,1424.840,
4217.09229,2493.598,5295.66406,1423.840,
4217.18408,2493.598,5295.75586,1423.840,
4217.27539,2493.598,5295.84717,1422.840,
4217.36719,2493.598,5295.93896,1423.840,
4217.45850,2492.598,5296.03027,1422.840,
4217.54980,2491.598,5296.12207,1421.840,
4217.64160,2491.598,5296.21338,1421.840,
4217.73291,2491.598,5296.30469,1420.840,
4217.82471,2491.598,5296.39648,1420.840,
4217.91602,2491.598,5296.48779,1419.840,
4218.00781,2491.598,5296.57959,1419.840,
4218.09912,2490.598,5296.67090,1419.840,
4218.19043,2491.598,5296.76270,1419.840,
4218.28223,2490.598,5296.85400,1418.840,
4218.37354,2490.598,5296.94531,1418.840,
4218.46533,2489.598,5297.03711,1417.840,
4218.55664,2489.598,5297.12842,1417.840,
4218.64844,2489.598,5297.22021,1417.840,
4218.73975,2488.598,5297.31152,1417.840,
4218.83105,2489.598,5297.40332,1416.840,
4218.92285,2488.598,5297.49463,1416.840,
4219.01416,2488.598,5297.58594,1416.840,
4219.10596,2487.598,5297.67773,1415.840,
4219.19727,2488.598,5297.76904,1415.840,
4219.28906,2487.598,5297.86084,1415.840,
4219.38037,2487.598,5297.95215,1415.840,
4219.47217,2487.598,5298.04395,1414.840,
4219.56348,2487.598,5298.13525,1414.840,
4219.65479,2487.598,5298.22705,1413.840,
4219.74658,2487.598,5298.31836,1413.840,
4219.83789,2486.598,5298.40967,1412.840,
4219.92969,2486.598,5298.50146,1413.840,
4220.02100,2486.598,5298.59277,1412.840,
4220.11279,2486.598,5298.68457,1412.840,
4220.20410,2485.598,5298.77588,1412.840,
4220.29541,2485.598,5298.86768,1412.840,
4220.38721,2485.598,5298.95898,1411.840,
4220.47852,2485.598,5299.05029,1411.840,
4220.57031,2484.598,5299.14209,1410.840,
4220.66162,2484.598,5299.23340,1410.840,
4220.75342,2483.598,5299.32520,1410.840,
4220.84473,2483.598,5299.41650,1410.840,
4220.93604,2483.598,5299.50830,1409.840,
4221.02783,2483.598,5299.59961,1409.840,
4221.11914,2483.598,5299.69092,1409.840,
4221.21094,2482.598,5299.78271,1408.840,
4221.30225,2483.598,5299.87402,1408.840,
4221.39404,2482.598,5299.96582,1408.840,
4221.48535,2482.598,5300.05713,1408.840,
4221.57666,2482.598,5300.14893,1407.840,
4221.66846,2481.598,5300.24023,1407.840,
4221.75977,2481.598,5300.33203,1407.840,
4221.85156,2481.598,5300.42334,1406.840,
4221.94287,2481.598,5300.51465,1406.840,
4222.03467,2480.598,5300.60645,1405.840,
4222.12598,2480.598,5300.69775,1405.840,
4222.21777,2480.598,5300.78955,1405.840,
4222.30908,2480.598,5300.88086,1405.840,
4222.40039,2480.598,5300.97266,1404.840,
4222.49219,2480.598,5301.06396,1404.840,
4222.58350,2480.598,5301.15527,1403.840,
4222.67529,2479.598,5301.24707,1403.840,
4222.76660,2479.598,5301.33838,1403.840,
4222.85840,2478.598,5301.43018,1402.840,
4222.94971,2478.598,5301.52148,1402.840,
4223.04102,2478.598,5301.61328,1402.840,
4223.13281,2478.598,5301.70459,1402.840,
4223.22412,2477.598,5301.79590,1402.840,
4223.31592,2477.598,5301.88770,1402.840,
4223.40723,2477.598,5301.97900,1401.840,
4223.49902,2477.598,5302.07080,1401.840,
4223.59033,2477.598,5302.16211,1400.840,
4223.68164,2476.598,5302.25391,1400.840,
4223.77344,2476.598,5302.34521,1399.840,
4223.86475,2476.598,5302.43701,1399.840,
4223.95654,2475.598,5302.52832,1399.840,
4224.04785,2476.598,5302.61963,1399.840,
4224.13965,2475.598,5302.71143,1398.840,
4224.23096,2475.598,5302.80273,1398.840,
4224.32275,2475.598,5302.89453,1398.840,
4224.41406,2475.598,5302.98584,1398.840,
4224.50537,2475.598,5303.07764,1397.840,
4224.59717,2475.598,5303.16895,1397.840,
4224.68848,2474.598,5303.26025,1397.840,
4224.78027,2474.598,5303.35205,1396.840,
4224.87158,2474.598,5303.44336,1396.840,
4224.96338,2474.598,5303.53516,1396.840,
4225.05469,2475.598,5303.62646,1395.840,
4225.14600,2475.598,5303.71826,1395.840,
4225.23779,2475.598,5303.80957,1395.840,
4225.32910,2475.598,5303.90088,1395.840,
4225.42090,2475.598,5303.99268,1394.840,
4225.51221,2475.598,5304.08398,1394.840,
4225.60400,2474.598,5304.17578,1394.840,
4225.69531,2474.598,5304.26709,1394.840,
4225.78662,2473.598,5304.35889,1393.840,
4225.87842,2473.598,5304.45020,1393.840,
4225.96973,2473.598,5304.54199,1393.840,
4226.06152,2472.598,5304.63330,1392.840,
4226.15283,2472.598,5304.72461,1393.840,
4226.24463,2471.598,5304.81641,1392.840,
4226.33594,2471.598,5304.90771,1391.840,
4226.42773,2470.598,5304.99951,1391.840,
4226.51904,2470.598,5305.09082,1391.840,
4226.61035,2470.598,5305.18262,1390.840,
4226.70215,2469.598,5305.27393,1390.840,
4226.79346,2468.598,5305.36523,1390.840,
4226.88525,2468.598,5305.45703,1390.840,
4226.97656,2469.598,5305.54834,1389.840,
4227.06836,2467.598,5305.64014,1389.840,
4227.15967,2467.598,5305.73145,1389.840,
4227.25098,2467.598,5305.82324,1388.840,
4227.34277,2466.598,5305.91455,1387.840,
4227.43408,2466.598,5306.00586,1388.840,
4227.52588,2465.598,5306.09766,1387.840,
4227.61719,2465.598,5306.18896,1388.840,
4227.70898,2464.598,5306.28076,1387.840,
4227.80029,2464.598,5306.37207,1387.840,
4227.89160,2464.598,5306.46387,1386.840,
4227.98340,2464.598,5306.55518,1387.840,
4228.07471,2464.598,5306.64648,1386.840,
4228.16650,2464.598,5306.73828,1386.840,
4228.25781,2464.598,5306.82959,1385.840,
4228.34961,2463.598,5306.92139,1385.840,
4228.44092,2464.598,5307.01270,1385.840,
4228.53271,2463.598,5307.10449,1384.840,
4228.62402,2463.598,5307.19580,1384.840,
4228.71533,2463.598,5307.28760,1384.840,
4228.80713,2463.598,5307.37891,1384.840,
4228.89844,2463.598,5307.47021,1383.840,
4228.99023,2463.598,5307.56201,1383.840,
4229.08154,2463.598,5307.65332,1383.840,
4229.17334,2462.598,5307.74512,1382.840,
4229.26465,2462.598,5307.83643,1382.840,
4229.35596,2461.598,5307.92822,1382.840,
4229.44775,2461.598,5308.01953,1381.840,
4229.53906,2461.598,5308.11084,1381.840,
4229.63086,2461.598,5308.20264,1380.840,
4229.72217,2461.598,5308.29395,1380.840,
4229.81396,2460.598,5308.38574,1380.840,
4229.90527,2461.598,5308.47705,1380.840,
4229.99658,2460.598,5308.56885,1379.840,
4230.08838,2460.598,5308.66016,1379.840,
4230.17969,2460.598,5308.75146,1379.840,
4230.27148,2459.598,5308.84326,1379.840,
4230.36279,2459.598,5308.93457,1378.840,
4230.45459,2459.598,5309.02637,1378.840,
4230.54590,2459.598,5309.11768,1379.840,
4230.63770,2459.598,5309.20947,1377.840,
4230.72900,2459.598,5309.30078,1378.840,
4230.82031,2458.598,5309.39258,1377.840,
4230.91211,2458.598,5309.48389,1377.840,
4231.00342,2458.598,5309.57520,1376.840,
4231.09521,2458.598,5309.66699,1376.840,
4231.18652,2458.598,5309.75830,1375.840,
4231.27832,2457.598,5309.85010,1374.840,
4231.36963,2458.598,5309.94141,1374.840,
4231.46094,2456.598,5310.03320,1373.840,
4231.55273,2456.598,5310.12451,1373.840,
4231.64404,2456.598,5310.21582,1373.840,
4231.73584,2456.598,5310.30762,1372.840,
4231.82715,2456.598,5310.39893,1372.840,
4231.91895,2455.598,5310.49072,1372.840,
4232.01025,2455.598,5310.58203,1373.840,
4232.10156,2455.598,5310.67383,1371.840,
4232.19336,2455.598,5310.76514,1371.840,
4232.28467,2454.598,5310.85645,1371.840,
4232.37646,2454.598,5310.94824,1371.840,
4232.46777,2454.598,5311.03955,1371.840,
4232.55957,2454.598,5311.13135,1371.840,
4232.65088,2454.598,5311.22266,1370.840,
4232.74268,2453.598,5311.31445,1370.840,
4232.83398,2454.598,5311.40576,1370.840,
4232.92529,2453.598,5311.49756,1369.840,
4233.01709,2452.598,5311.58887,1369.840,
4233.10840,2452.598,5311.68018,1369.840,
4233.20020,2452.598,5311.77197,1369.840,
4233.29150,2452.598,5311.86328,1369.840,
4233.38330,2451.598,5311.95508,1369.840,
4233.47461,2452.598,5312.04639,1370.840,
4233.56592,2451.598,5312.13818,1369.840,
4233.65771,2451.598,5312.22949,1370.840,
4233.74902,2451.598,5312.32080,1370.840,
4233.84082,2450.598,5312.41260,1371.840,
4233.93213,2450.598,5312.50391,1371.840,
4234.02393,2450.598,5312.59570,1371.840,
4234.11523,2450.598,5312.68701,1370.840,
4234.20654,2449.598,5312.77881,1370.840,
4234.29834,2449.598,5312.87012,1370.840,
4234.38965,2449.598,5312.96143,1369.840,
4234.48145,2449.598,5313.05322,1369.840,
4234.57275,2449.598,5313.14453,1368.840,
4234.66455,2449.598,5313.23633,1368.840,
4234.75586,2448.598,5313.32764,1367.840,
4234.84717,2448.598,5313.41943,1366.840,
4234.93896,2447.598,5313.51074,1366.840,
4235.03027,2448.598,5313.60254,1365.840,
4235.12207,2447.598,5313.69385,1364.840,
4235.21338,2447.598,5313.78516,1364.840,
4235.30518,2447.598,5313.87695,1363.840,
4235.39648,2446.598,5313.96826,1362.840,
4235.48828,2446.598,5314.06006,1362.840,
4235.57959,2446.598,5314.15137,1362.840,
4235.67090,2445.598,5314.24316,1361.840,
4235.76270,2446.598,5314.33447,1361.840,
4235.85400,2445.598,5314.42578,1361.840,
4235.94580,2445.598,5314.51758,1360.840,
4236.03711,2445.598,5314.60889,1359.840,
4236.12891,2444.598,5314.70068,1360.840,
4236.22021,2444.598,5314.79199,1360.840,
4236.31152,2444.598,5314.88379,1358.840,
4236.40332,2444.598,5314.97510,1359.840,
4236.49463,2444.598,5315.06641,1359.840,
4236.58643,2443.598,5315.15820,1358.840,
4236.67773,2443.598,5315.24951,1358.840,
4236.76953,2443.598,5315.34131,1358.840,
4236.86084,2442.598,5315.43262,1357.840,
4236.95215,2442.598,5315.52441,1357.840,
4237.04395,2442.598,5315.61572,1357.840,
4237.13525,2442.598,5315.70752,1357.840,
4237.22705,2442.598,5315.79883,1356.840,
4237.31836,2441.598,5315.89014,1356.840,
4237.41016,2441.598,5315.98193,1355.840,
4237.50146,2441.598,5316.07324,1355.840,
4237.59326,2440.598,5316.16504,1355.840,
4237.68457,2441.598,5316.25635,1355.840,
4237.77588,2440.598,5316.34814,1354.840,
4237.86768,2440.598,5316.43945,1354.840,
4237.95898,2440.598,5316.53076,1354.840,
4238.05078,2439.598,5316.62256,1353.840,
4238.14209,2439.598,5316.71387,1353.840,
4238.23389,2439.598,5316.80566,1353.840,
4238.32520,2439.598,5316.89697,1353.840,
4238.41650,2439.598,5316.98877,1352.840,
4238.50830,2438.598,5317.08008,1352.840,
4238.59961,2438.598,5317.17139,1352.840,
4238.69141,2439.598,5317.26318,1351.840,
4238.78271,2438.598,5317.35449,1351.840,
4238.87451,2438.598,5317.44629,1351.840,
4238.96582,2438.598,5317.53760,1350.840,
4239.05713,2437.598,5317.62939,1351.840,
4239.14893,2437.598,5317.72070,1350.840,
4239.24023,2437.598,5317.81250,1350.840,
4239.33203,2436.598,5317.90381,1350.840,
4239.42334,2437.598,5317.99512,1349.840,
4239.51514,2436.598,5318.08691,1349.840,
4239.60645,2436.598,5318.17822,1349.840,
4239.69824,2435.598,5318.27002,1348.840,
4239.78955,2435.598,5318.36133,1348.840,
4239.88086,2435.598,5318.45313,1348.840,
4239.97266,2434.598,5318.54443,1348.840,
4240.06396,2434.598,5318.63574,1347.840,
4240.15576,2434.598,5318.72754,1347.840,
4240.24707,2434.598,5318.81885,1346.840,
4240.33887,2434.598,5318.91064,1346.840,
4240.43018,2434.598,5319.00195,1346.840,
4240.52148,2433.598,5319.09375,1345.840,
4240.61328,2433.598,5319.18506,1345.840,
4240.70459,2433.598,5319.27637,1345.840,
4240.79639,2433.598,5319.36816,1345.840,
4240.88770,2433.598,5319.45947,1344.840,
4240.97949,2432.598,5319.55127,1344.840,
4241.07080,2432.598,5319.64258,1344.840,
4241.16211,2431.598,5319.73438,1343.840,
4241.25391,2431.598,5319.82568,1343.840,
4241.34521,2432.598,5319.91699,1343.840,
4241.43701,2431.598,5320.00879,1343.840,
4241.52832,2431.598,5320.10010,1343.840,
4241.62012,2431.598,5320.19189,1342.840,
4241.71143,2430.598,5320.28320,1341.840,
4241.80322,2430.598,5320.37500,1341.840,
4241.89453,2430.598,5320.46631,1342.840,
4241.98584,2429.598,5320.55811,1341.840,
4242.07764,2429.598,5320.64941,1340.840,
4242.16895,2430.598,5320.74072,1340.840,
4242.26074,2429.598,5320.83252,1341.840,
4242.35205,2429.598,5320.92383,1340.840,
4242.44385,2429.598,5321.01563,1339.840,
4242.53516,2428.598,5321.10693,1339.840,
4242.62646,2428.598,5321.19873,1339.840,
4242.71826,2427.598,5321.29004,1339.840,
4242.80957,2427.598,5321.38135,1339.840,
4242.90137,2427.598,5321.47314,1338.840,
4242.99268,2427.598,5321.56445,1338.840,
4243.08447,2427.598,5321.65625,1338.840,
4243.17578,2426.598,5321.74756,1337.840,
4243.26709,2426.598,5321.83936,1337.840,
4243.35889,2426.598,5321.93066,1337.840,
4243.45020,2426.598,5322.02197,1336.840,
4243.54199,2425.598,5322.11377,1336.840,
4243.63330,2424.598,5322.20508,1336.840,
4243.72510,2423.598,5322.29688,1336.840,
4243.81641,2423.598,5322.38818,1335.840,
4243.90820,2422.598,5322.47998,1335.840,
4243.99951,2421.598,5322.57129,1335.840,
4244.09082,2421.598,5322.66309,1334.840,
4244.18262,2421.598,5322.75439,1334.840,
4244.27393,2421.598,5322.84570,1333.840,
4244.36572,2420.598,5322.93750,1334.840,
4244.45703,2421.598,5323.02881,1333.840,
4244.54883,2421.598,5323.12061,1333.840,
4244.64014,2420.598,5323.21191,1332.840,
4244.73145,2420.598,5323.30371,1332.840,
4244.82324,2420.598,5323.39502,1331.840,
4244.91455,2420.598,5323.48633,1331.840,
4245.00635,2420.598,5323.57813,1331.840,
4245.09766,2420.598,5323.66943,1331.840,
4245.18945,2420.598,5323.76123,1331.840,
4245.28076,2420.598,5323.85254,1330.840,
4245.37207,2420.598,5323.94434,1330.840,
4245.46387,2420.598,5324.03564,1329.840,
4245.55518,2419.598,5324.12695,1329.840,
4245.64697,2419.598,5324.21875,1329.840,
4245.73828,2419.598,5324.31006,1329.840,
4245.83008,2419.598,5324.40186,1329.840,
4245.92139,2419.598,5324.49316,1328.840,
4246.01270,2420.598,5324.58496,1327.840,
4246.10449,2419.598,5324.67627,1328.840,
4246.19580,2420.598,5324.76807,1327.840,
4246.28760,2419.598,5324.85938,1327.840,
4246.37891,2420.598,5324.95068,1327.840,
4246.47070,2419.598,5325.04248,1326.840,
4246.56201,2420.598,5325.13379,1326.840,
4246.65381,2419.598,5325.22559,1327.840,
4246.74512,2419.598,5325.31689,1326.840,
4246.83643,2418.598,5325.40869,1325.840,
4246.92822,2418.598,5325.50000,1325.840,
4247.01953,2418.598,5325.59131,1325.840,
4247.11133,2417.598,5325.68311,1325.840,
4247.20264,2417.598,5325.77441,1324.840,
4247.29443,2417.598,5325.86621,1324.840,
4247.38574,2416.598,5325.95752,1324.840,
4247.47705,2416.598,5326.04932,1323.840,
4247.56885,2415.598,5326.14063,1323.840,
4247.66016,2415.598,5326.23193,1322.840,
4247.75195,2415.598,5326.32373,1322.840,
4247.84326,2415.598,5326.41504,1322.840,
4247.93506,2414.598,5326.50684,1322.840,
4248.02637,2414.598,5326.59814,1322.840,
4248.11768,2413.598,5326.68994,1321.840,
4248.20947,2413.598,5326.78125,1321.840,
4248.30078,2413.598,5326.87305,1321.840,
4248.39258,2413.598,5326.96436,1320.840,
4248.48389,2412.598,5327.05566,1320.840,
4248.57568,2412.598,5327.14746,1320.840,
4248.66699,2412.598,5327.23877,1320.840,
4248.75879,2411.598,5327.33057,1320.840,
4248.85010,2411.598,5327.42188,1319.840,
4248.94141,2412.598,5327.51367,1319.840,
4249.03320,2411.598,5327.60498,1318.840,
4249.12451,2411.598,5327.69629,1317.840,
4249.21631,2410.598,5327.78809,1316.840,
4249.30762,2410.598,5327.87939,1315.840,
4249.39941,2410.598,5327.97119,1314.840,
4249.49072,2410.598,5328.06250,1314.840,
4249.58203,2410.598,5328.15430,1314.840,
4249.67383,2409.598,5328.24561,1313.840,
4249.76514,2408.598,5328.33691,1313.840,
4249.85693,2409.598,5328.42871,1313.840,
4249.94824,2408.598,5328.52002,1313.840,
4250.04004,2408.598,5328.61182,1313.840,
4250.13135,2408.598,5328.70313,1313.840,
4250.22266,2407.598,5328.79492,1313.840,
4250.31445,2407.598,5328.88623,1313.840,
4250.40576,2407.598,5328.97803,1312.840,
4250.49756,2407.598,5329.06934,1312.840,
4250.58887,2406.598,5329.16064,1312.840,
4250.68066,2407.598,5329.25244,1312.840,
4250.77197,2406.598,5329.34375,1312.840,
4250.86377,2406.598,5329.43555,1312.840,
4250.95508,2406.598,5329.52686,1311.840,
4251.04639,2406.598,5329.61865,1312.840,
4251.13818,2405.598,5329.70996,1311.840,
4251.22949,2405.598,5329.80127,1312.840,
4251.32129,2405.598,5329.89307,1311.840,
4251.41260,2404.598,5329.98438,1311.840,
4251.50439,2405.598,5330.07617,1311.840,
4251.59570,2404.598,5330.16748,1311.840,
4251.68701,2404.598,5330.25928,1310.840,
4251.77881,2403.598,5330.35059,1309.840,
4251.87012,2404.598,5330.44189,1309.840,
4251.96191,2403.598,5330.53369,1308.840,
4252.05322,2403.598,5330.62500,1308.840,
4252.14502,2403.598,5330.71680,1307.840,
4252.23633,2402.598,5330.80811,1307.840,
4252.32764,2402.598,5330.89990,1306.840,
4252.41943,2402.598,5330.99121,1306.840,
4252.51074,2401.598,5331.08252,1306.840,
4252.60254,2402.598,5331.17432,1306.840,
4252.69385,2401.598,5331.26563,1305.840,
4252.78564,2401.598,5331.35742,1306.840,
4252.87695,2401.598,5331.44873,1305.840,
4252.96875,2401.598,5331.54053,1305.840,
4253.06006,2399.598,5331.63184,1305.840,
4253.15137,2400.598,5331.72363,1305.840,
4253.24316,2399.598,5331.81494,1304.840,
4253.33447,2400.598,5331.90625,1303.840,
4253.42627,2400.598,5331.99805,1304.840,
4253.51758,2399.598,5332.08936,1303.840,
4253.60938,2399.598,5332.18115,1303.840,
4253.70068,2398.598,5332.27246,1303.840,
4253.79199,2398.598,5332.36426,1302.840,
4253.88379,2398.598,5332.45557,1302.840,
4253.97510,2398.598,5332.54688,1303.840,
4254.06689,2398.598,5332.63867,1302.840,
4254.15820,2397.598,5332.72998,1301.840,
4254.25000,2397.598,5332.82178,1301.840,
4254.34131,2397.598,5332.91309,1301.840,
4254.43262,2397.598,5333.00488,1301.840,
4254.52441,2396.598,5333.09619,1301.840,
4254.61572,2396.598,5333.18750,1300.840,
4254.70752,2396.598,5333.27930,1300.840,
4254.79883,2396.598,5333.37061,1299.840,
4254.89063,2395.598,5333.46240,1299.840,
4254.98193,2395.598,5333.55371,1299.840,
4255.07373,2395.598,5333.64551,1299.840,
4255.16504,2395.598,5333.73682,1299.840,
4255.25635,2394.598,5333.82861,1298.840,
4255.34814,2394.598,5333.91992,1298.840,
4255.43945,2394.598,5334.01123,1298.840,
4255.53125,2393.598,5334.10303,1297.840,
4255.62256,2393.598,5334.19434,1297.840,
4255.71436,2393.598,5334.28613,1297.840,
4255.80566,2393.598,5334.37744,1297.840,
4255.89697,2393.598,5334.46924,1296.840,
4255.98877,2392.598,5334.56055,1296.840,
4256.08008,2392.598,5334.65186,1296.840,
4256.17188,2392.598,5334.74365,1296.840,
4256.26318,2392.598,5334.83496,1295.840,
4256.35498,2391.598,5334.92676,1295.840,
4256.44629,2391.598,5335.01807,1295.840,
4256.53760,2391.598,5335.10986,1295.840,
4256.62939,2391.598,5335.20117,1294.840,
4256.72070,2390.598,5335.29248,1294.840,
4256.81250,2390.598,5335.38428,1293.840,
4256.90381,2390.598,5335.47559,1293.840,
4256.99561,2390.598,5335.56738,1293.840,
4257.08691,2389.598,5335.65869,1292.840,
4257.17871,2389.598,5335.75049,1292.840,
4257.27002,2389.598,5335.84180,1292.840,
4257.36133,2389.598,5335.93359,1292.840,
4257.45313,2388.598,5336.02490,1292.840,
4257.54443,2389.598,5336.11621,1291.840,
4257.63623,2388.598,5336.20801,1292.840,
4257.72754,2388.598,5336.29932,1291.840,
4257.81934,2387.598,5336.39111,1290.840,
4257.91064,2387.598,5336.48242,1290.840,
4258.00195,2387.598,5336.57422,1290.840,
4258.09375,2387.598,5336.66553,1290.840,
4258.18506,2387.598,5336.75684,1290.840,
4258.27686,2387.598,5336.84863,1289.840,
4258.36816,2386.598,5336.93994,1289.840,
4258.45996,2386.598,5337.03174,1288.840,
4258.55127,2385.598,5337.12305,1288.840,
4258.64258,2385.598,5337.21484,1288.840,
4258.73438,2385.598,5337.30615,1288.840,
4258.82568,2385.598,5337.39746,1287.840,
4258.91748,2384.598,5337.48926,1286.840,
4259.00879,2384.598,5337.58057,1286.840,
4259.10059,2384.598,5337.67236,1287.840,
4259.19189,2384.598,5337.76367,1286.840,
4259.28320,2383.598,5337.85547,1285.840,
4259.37500,2383.598,5337.94678,1285.840,
4259.46631,2383.598,5338.03857,1285.840,
4259.55811,2383.598,5338.12988,1284.840,
4259.64941,2382.598,5338.22119,1284.840,
4259.74121,2382.598,5338.31299,1283.840,
4259.83252,2382.598,5338.40430,1284.840,
4259.92432,2382.598,5338.49609,1283.840,
4260.01563,2382.598,5338.58740,1283.840,
4260.10693,2381.598,5338.67920,1283.840,
4260.19873,2381.598,5338.77051,1282.840,
4260.29004,2381.598,5338.86182,1282.840,
4260.38184,2381.598,5338.95361,1282.840,
4260.47314,2381.598,5339.04492,1282.840,
4260.56494,2380.598,5339.13672,1281.840,
4260.65625,2380.598,5339.22803,1281.840,
4260.74756,2380.598,5339.31982,1280.840,
4260.83936,2379.598,5339.41113,1280.840,
4260.93066,2379.598,5339.50244,1280.840,
4261.02246,2379.598,5339.59424,1279.840,
4261.11377,2378.598,5339.68555,1279.840,
4261.20557,2378.598,5339.77734,1279.840,
4261.29688,2378.598,5339.86865,1279.840,
4261.38818,2378.598,5339.96045,1278.840,
4261.47998,2377.598,5340.05176,1278.840,
4261.57129,2378.598,5340.14355,1277.840,
4261.66309,2377.598,5340.23486,1277.840,
4261.75439,2377.598,5340.32617,1277.840,
4261.84619,2377.598,5340.41797,1277.840,
4261.93750,2376.598,5340.50928,1276.840,
4262.02930,2376.598,5340.60107,1276.840,
4262.12061,2377.598,5340.69238,1276.840,
4262.21191,2376.598,5340.78418,1276.840,
4262.30371,2375.598,5340.87549,1275.840,
4262.39502,2375.598,5340.96680,1275.840,
4262.48682,2374.598,5341.05859,1275.840,
4262.57813,2374.598,5341.14990,1275.840,
4262.66992,2373.598,5341.24170,1274.840,
4262.76123,2372.598,5341.33301,1275.840,
4262.85254,2371.598,5341.42480,1274.840,
4262.94434,2371.598,5341.51611,1273.840,
4263.03564,2371.598,5341.60742,1273.840,
4263.12744,2371.598,5341.69922,1273.840,
4263.21875,2371.598,5341.79053,1273.840,
4263.31055,2371.598,5341.88232,1273.840,
4263.40186,2370.598,5341.97363,1273.840,
4263.49316,2370.598,5342.06543,1272.840,
4263.58496,2371.598,5342.15674,1271.840,
4263.67627,2370.598,5342.24854,1272.840,
4263.76807,2370.598,5342.33984,1271.840,
4263.85938,2370.598,5342.43115,1271.840,
4263.95117,2370.598,5342.52295,1270.840,
4264.04248,2370.598,5342.61426,1271.840,
4264.13428,2370.598,5342.70605,1269.840,
4264.22559,2370.598,5342.79736,1270.840,
4264.31689,2370.598,5342.88916,1269.840,
4264.40869,2369.598,5342.98047,1269.840,
4264.50000,2369.598,5343.07178,1269.840,
4264.59180,2369.598,5343.16357,1268.840,
4264.68311,2369.598,5343.25488,1268.840,
4264.77490,2369.598,5343.34668,1268.840,
4264.86621,2369.598,5343.43799,1267.840,
4264.95752,2370.598,5343.52979,1267.840,
4265.04932,2370.598,5343.62109,1267.840,
4265.14063,2371.598,5343.71240,1267.840,
4265.23242,2371.598,5343.80420,1267.840,
4265.32373,2371.598,5343.89551,1266.840,
4265.41553,2370.598,5343.98730,1266.840,
4265.50684,2370.598,5344.07861,1265.840,
4265.59814,2370.598,5344.17041,1265.840,
4265.68994,2370.598,5344.26172,1266.840,
4265.78125,2369.598,5344.35303,1265.840,
4265.87305,2369.598,5344.44482,1264.840,
4265.96436,2368.598,5344.53613,1264.840,
4266.05615,2368.598,5344.62793,1264.840,
4266.14746,2367.598,5344.71924,1263.840,
4266.23926,2366.598,5344.81104,1263.840,
4266.33057,2366.598,5344.90234,1263.840,
4266.42188,2365.598,5344.99414,1263.840,
4266.51367,2366.598,5345.08545,1262.840,
4266.60498,2365.598,5345.17676,1262.840,
4266.69678,2364.598,5345.26855,1262.840,
4266.78809,2364.598,5345.35986,1261.840,
4266.87988,2364.598,5345.45166,1261.840,
4266.97119,2364.598,5345.54297,1260.840,
4267.06250,2363.598,5345.63477,1259.840,
4267.15430,2362.598,5345.72607,1260.840,
4267.24561,2362.598,5345.81738,1259.840,
4267.33740,2362.598,5345.90918,1258.840,
4267.42871,2362.598,5346.00049,1258.840,
4267.52051,2362.598,5346.09229,1257.840,
4267.61182,2361.598,5346.18359,1257.840,
4267.70313,2361.598,5346.27539,1256.840,
4267.79492,2361.598,5346.36670,1256.840,
4267.88623,2360.598,5346.45801,1256.840,
4267.97803,2361.598,5346.54980,1256.840,
4268.06934,2360.598,5346.64111,1255.840,
4268.16113,2360.598,5346.73291,1255.840,
4268.25244,2360.598,5346.82422,1255.840,
4268.34424,2359.598,5346.91602,1255.840,
4268.43555,2359.598,5347.00732,1255.840,
4268.52686,2358.598,5347.09912,1255.840,
4268.61865,2358.598,5347.19043,1255.840,
4268.70996,2358.598,5347.28174,1254.840,
4268.80176,2358.598,5347.37354,1255.840,
4268.89307,2358.598,5347.46484,1254.840,
4268.98486,2358.598,5347.55664,1254.840,
4269.07617,2357.598,5347.64795,1254.840,
4269.16748,2357.598,5347.73975,1254.840,
4269.25928,2357.598,5347.83105,1254.840,
4269.35059,2357.598,5347.92236,1254.840,
4269.44238,2356.598,5348.01416,1254.840,
4269.53369,2356.598,5348.10547,1254.840,
4269.62549,2356.598,5348.19727,1254.840,
4269.71680,2355.598,5348.28857,1254.840,
4269.80811,2355.598,5348.38037,1255.840,
4269.89990,2355.598,5348.47168,1255.840,
4269.99121,2354.598,5348.56299,1255.840,
4270.08301,2354.598,5348.65479,1255.840,
4270.17432,2354.598,5348.74609,1254.840,
4270.26611,2354.598,5348.83789,1253.840,
4270.35742,2353.598,5348.92920,1253.840,
4270.44922,2353.598,5349.02100,1252.840,
4270.54053,2353.598,5349.11230,1252.840,
4270.63184,2352.598,5349.20410,1251.840,
4270.72363,2352.598,5349.29541,1250.840,
4270.81494,2352.598,5349.38672,1250.840,
4270.90674,2353.598,5349.47852,1249.840,
4270.99805,2351.598,5349.56982,1249.840,
4271.08984,2351.598,5349.66162,1248.840,
4271.18115,2351.598,5349.75293,1248.840,
4271.27246,2351.598,5349.84473,1248.840,
4271.36426,2351.598,5349.93604,1247.840,
4271.45557,2350.598,5350.02734,1247.840,
4271.54736,2351.598,5350.11914,1247.840,
4271.63867,2350.598,5350.21045,1246.840,
4271.73047,2350.598,5350.30225,1246.840,
4271.82178,2349.598,5350.39355,1247.840,
4271.91309,2349.598,5350.48535,1246.840,
4272.00488,2349.598,5350.57666,1245.840,
4272.09619,2348.598,5350.66797,1245.840,
4272.18799,2349.598,5350.75977,1245.840,
4272.27930,2348.598,5350.85107,1244.840,
4272.37109,2348.598,5350.94287,1244.840,
4272.46240,2347.598,5351.03418,1244.840,
4272.55371,2347.598,5351.12598,1244.840,
4272.64551,2347.598,5351.21729,1244.840,
4272.73682,2347.598,5351.30908,1243.840,
4272.82861,2346.598,5351.40039,1243.840,
4272.91992,2346.598,5351.49170,1242.840,
4273.01172,2346.598,5351.58350,1243.840,
4273.10303,2346.598,5351.67480,1242.840,
4273.19482,2345.598,5351.76660,1242.840,
4273.28613,2345.598,5351.85791,1241.840,
4273.37744,2345.598,5351.94971,1241.840,
4273.46924,2345.598,5352.04102,1241.840,
4273.56055,2344.598,5352.13232,1241.840,
4273.65234,2344.598,5352.22412,1241.840,
4273.74365,2344.598,5352.31543,1240.840,
4273.83545,2345.598,5352.40723,1239.840,
4273.92676,2344.598,5352.49854,1240.840,
4274.01807,2343.598,5352.59033,1239.840,
4274.10986,2343.598,5352.68164,1239.840,
4274.20117,2343.598,5352.77295,1238.840,
4274.29297,2343.598,5352.86475,1238.840,
4274.38428,2342.598,5352.95605,1238.840,
4274.47607,2342.598,5353.04785,1238.840,
4274.56738,2342.598,5353.13916,1238.840,
4274.65869,2342.598,5353.23096,1237.840,
4274.75049,2341.598,5353.32227,1237.840,
4274.84180,2342.598,5353.41406,1236.840,
4274.93359,2341.598,5353.50537,1236.840,
4275.02490,2341.598,5353.59668,1236.840,
4275.11670,2341.598,5353.68848,1236.840,
4275.20801,2340.598,5353.77979,1236.840,
4275.29980,2341.598,5353.87158,1235.840,
4275.39111,2339.598,5353.96289,1235.840,
4275.48242,2339.598,5354.05469,1235.840,
4275.57422,2339.598,5354.14600,1234.840,
4275.66553,2339.598,5354.23730,1234.840,
4275.75732,2339.598,5354.32910,1234.840,
4275.84863,2339.598,5354.42041,1234.840,
4275.94043,2338.598,5354.51221,1233.840,
4276.03174,2338.598,5354.60352,1233.840,
4276.12305,2338.598,5354.69531,1232.840,
4276.21484,2337.598,5354.78662,1232.840,
4276.30615,2337.598,5354.87793,1232.840,
4276.39795,2337.598,5354.96973,1232.840,
4276.48926,2337.598,5355.06104,1231.840,
4276.58105,2336.598,5355.15283,1231.840,
4276.67236,2336.598,5355.24414,1231.840,
4276.76367,2337.598,5355.33594,1231.840,
4276.85547,2335.598,5355.42725,1230.840,
4276.94678,2336.598,5355.51904,1230.840,
4277.03857,2335.598,5355.61035,1230.840,
4277.12988,2335.598,5355.70166,1229.840,
4277.22168,2334.598,5355.79346,1229.840,
4277.31299,2335.598,5355.88477,1229.840,
4277.40479,2334.598,5355.97656,1230.840,
4277.49609,2334.598,5356.06787,1229.840,
4277.58740,2334.598,5356.15967,1229.840,
4277.67920,2334.598,5356.25098,1228.840,
4277.77051,2333.598,5356.34229,1228.840,
4277.86230,2333.598,5356.43408,1227.840,
4277.95361,2332.598,5356.52539,1227.840,
4278.04541,2332.598,5356.61719,1227.840,
4278.13672,2332.598,5356.70850,1227.840,
4278.22803,2332.598,5356.80029,1226.840,
4278.31982,2332.598,5356.89160,1226.840,
4278.41113,2331.598,5356.98291,1226.840,
4278.50293,2331.598,5357.07471,1225.840,
4278.59424,2331.598,5357.16602,1225.840,
4278.68604,2330.598,5357.25781,1225.840,
4278.77734,2331.598,5357.34912,1224.840,
4278.86865,2330.598,5357.44092,1224.840,
4278.96045,2330.598,5357.53223,1224.840,
4279.05176,2329.598,5357.62354,1224.840,
4279.14355,2329.598,5357.71533,1224.840,
4279.23486,2329.598,5357.80664,1223.840,
4279.32666,2329.598,5357.89844,1223.840,
4279.41797,2329.598,5357.98975,1223.840,
4279.50977,2328.598,5358.08154,1223.840,
4279.60107,2328.598,5358.17285,1222.840,
4279.69238,2328.598,5358.26465,1222.840,
4279.78418,2328.598,5358.35596,1221.840,
4279.87549,2327.598,5358.44727,1221.840,
4279.96729,2327.598,5358.53906,1221.840,
4280.05859,2327.598,5358.63037,1221.840,
4280.15039,2326.598,5358.72217,1220.840,
4280.24170,2326.598,5358.81348,1220.840,
4280.33301,2326.598,5358.90527,1221.840,
4280.42480,2326.598,5358.99658,1220.840,
4280.51611,2325.598,5359.08789,1220.840,
4280.60791,2325.598,5359.17969,1219.840,
4280.69922,2325.598,5359.27100,1219.840,
4280.79102,2325.598,5359.36279,1219.840,
4280.88232,2324.598,5359.45410,1219.840,
4280.97363,2324.598,5359.54590,1218.840,
4281.06543,2324.598,5359.63721,1218.840,
4281.15674,2324.598,5359.72852,1218.840,
4281.24854,2323.598,5359.82031,1217.840,
4281.33984,2323.598,5359.91162,1217.840,
4281.43164,2323.598,5360.00342,1217.840,
4281.52295,2324.598,5360.09473,1216.840,
4281.61475,2324.598,5360.18652,1216.840,
4281.70605,2325.598,5360.27783,1216.840,
4281.79736,2325.598,5360.36963,1216.840,
4281.88916,2325.598,5360.46094,1215.840,
4281.98047,2325.598,5360.55225,1215.840,
4282.07227,2325.598,5360.64404,1215.840,
4282.16357,2325.598,5360.73535,1214.840,
4282.25537,2324.598,5360.82715,1214.840,
4282.34668,2324.598,5360.91846,1214.840,
4282.43799,2323.598,5361.01025,1214.840,
4282.52979,2322.598,5361.10156,1213.840,
4282.62109,2322.598,5361.19287,1213.840,
4282.71289,2322.598,5361.28467,1213.840,
4282.80420,2321.598,5361.37598,1212.840,
4282.89600,2321.598,5361.46777,1212.840,
4282.98730,2320.598,5361.55908,1212.840,
4283.07861,2319.598,5361.65088,1212.840,
4283.17041,2319.598,5361.74219,1211.840,
4283.26172,2319.598,5361.83350,1212.840,
4283.35352,2318.598,5361.92529,1210.840,
4283.44482,2318.598,5362.01660,1211.840,
4283.53662,2316.598,5362.10840,1210.840,
4283.62793,2317.598,5362.19971,1210.840,
4283.71924,2316.598,5362.29150,1209.840,
4283.81104,2316.598,5362.38281,1209.840,
4283.90234,2316.598,5362.47461,1209.840,
4283.99414,2316.598,5362.56592,1209.840,
4284.08545,2316.598,5362.65723,1208.840,
4284.17725,2315.598,5362.74902,1209.840,
4284.26855,2315.598,5362.84033,1208.840,
4284.36035,2315.598,5362.93213,1207.840,
4284.45166,2315.598,5363.02344,1207.840,
4284.54297,2314.598,5363.11523,1207.840,
4284.63477,2314.598,5363.20654,1207.840,
4284.72607,2314.598,5363.29785,1207.840,
4284.81787,2314.598,5363.38965,1206.840,
4284.90918,2313.598,5363.48096,1206.840,
4285.00098,2314.598,5363.57275,1206.840,
4285.09229,2313.598,5363.66406,1206.840,
4285.18359,2313.598,5363.75586,1206.840,
4285.27539,2313.598,5363.84717,1206.840,
4285.36670,2313.598,5363.93848,1206.840,
4285.45850,2312.598,5364.03027,1206.840,
4285.54980,2312.598,5364.12158,1207.840,
4285.64160,2312.598,5364.21338,1206.840,
4285.73291,2312.598,5364.30469,1206.840,
4285.82422,2312.598,5364.39648,1206.840,
4285.91602,2311.598,5364.48779,1205.840,
4286.00732,2311.598,5364.57959,1205.840,
4286.09912,2310.598,5364.67090,1204.840,
4286.19043,2310.598,5364.76221,1204.840,
4286.28223,2310.598,5364.85400,1204.840,
4286.37354,2309.598,5364.94531,1203.840,
4286.46533,2309.598,5365.03711,1203.840,
4286.55664,2308.598,5365.12842,1203.840,
4286.64795,2309.598,5365.22021,1202.840,
4286.73975,2308.598,5365.31152,1201.840,
4286.83105,2308.598,5365.40283,1201.840,
4286.92285,2308.598,5365.49463,1201.840,
4287.01416,2308.598,5365.58594,1200.840,
4287.10596,2307.598,5365.67773,1200.840,
4287.19727,2307.598,5365.76904,1200.840,
4287.28857,2306.598,5365.86084,1199.840,
4287.38037,2306.598,5365.95215,1198.840,
4287.47168,2306.598,5366.04346,1197.840,
4287.56348,2306.598,5366.13525,1196.840,
4287.65479,2306.598,5366.22656,1195.840,
4287.74658,2305.598,5366.31836,1194.840,
4287.83789,2305.598,5366.40967,1193.840,
4287.92920,2305.598,5366.50146,1193.840,
4288.02100,2304.598,5366.59277,1192.840,
4288.11230,2304.598,5366.68457,1192.840,
4288.20410,2303.598,5366.77588,1192.840,
4288.29541,2304.598,5366.86719,1192.840,
4288.38721,2303.598,5366.95898,1192.840,
4288.47852,2303.598,5367.05029,1191.840,
4288.57031,2303.598,5367.14209,1192.840,
4288.66162,2303.598,5367.23340,1191.840,
4288.75293,2302.598,5367.32520,1192.840,
4288.84473,2302.598,5367.41650,1191.840,
4288.93604,2302.598,5367.50781,1191.840,
4289.02783,2302.598,5367.59961,1192.840,
4289.11914,2301.598,5367.69092,1193.840,
4289.21094,2301.598,5367.78271,1191.840,
4289.30225,2301.598,5367.87402,1192.840,
4289.39355,2300.598,5367.96582,1192.840,
4289.48535,2301.598,5368.05713,1191.840,
4289.57666,2300.598,5368.14844,1192.840,
4289.66846,2299.598,5368.24023,1191.840,
4289.75977,2300.598,5368.33154,1191.840,
4289.85156,2299.598,5368.42334,1191.840,
4289.94287,2299.598,5368.51465,1190.840,
4290.03418,2299.598,5368.60645,1191.840,
4290.12598,2299.598,5368.69775,1190.840,
4290.21729,2298.598,5368.78906,1190.840,
4290.30908,2298.598,5368.88086,1189.840,
4290.40039,2298.598,5368.97217,1189.840,
4290.49219,2297.598,5369.06396,1189.840,
4290.58350,2297.598,5369.15527,1189.840,
4290.67529,2297.598,5369.24707,1189.840,
4290.76660,2297.598,5369.33838,1188.840,
4290.85791,2296.598,5369.43018,1188.840,
4290.94971,2296.598,5369.52148,1188.840,
4291.04102,2296.598,5369.61279,1187.840,
4291.13281,2296.598,5369.70459,1187.840,
4291.22412,2295.598,5369.79590,1187.840,
4291.31592,2295.598,5369.88770,1187.840,
4291.40723,2295.598,5369.97900,1186.840,
4291.49854,2294.598,5370.07080,1186.840,
4291.59033,2294.598,5370.16211,1186.840,
4291.68164,2294.598,5370.25342,1185.840,
4291.77344,2294.598,5370.34521,1186.840,
4291.86475,2294.598,5370.43652,1185.840,
4291.95654,2293.598,5370.52832,1185.840,
4292.04785,2293.598,5370.61963,1185.840,
4292.13916,2293.598,5370.71143,1184.840,
4292.23096,2293.598,5370.80273,1184.840,
4292.32227,2292.598,5370.89404,1183.840,
4292.41406,2292.598,5370.98584,1184.840,
4292.50537,2292.598,5371.07715,1183.840,
4292.59717,2292.598,5371.16895,1183.840,
4292.68848,2291.598,5371.26025,1183.840,
4292.78027,2291.598,5371.35205,1182.840,
4292.87158,2291.598,5371.44336,1182.840,
4292.96289,2290.598,5371.53516,1181.840,
4293.05469,2290.598,5371.62646,1181.840,
4293.14600,2290.598,5371.71777,1181.840,
4293.23779,2290.598,5371.80957,1181.840,
4293.32910,2289.598,5371.90088,1181.840,
4293.42090,2289.598,5371.99268,1180.840,
4293.51221,2289.598,5372.08398,1180.840,
4293.60352,2289.598,5372.17578,1180.840,
4293.69531,2289.598,5372.26709,1180.840,
4293.78662,2288.598,5372.35840,1179.840,
4293.87842,2288.598,5372.45020,1179.840,
4293.96973,2288.598,5372.54150,1179.840,
4294.06152,2287.598,5372.63330,1178.840,
4294.15283,2287.598,5372.72461,1178.840,
4294.24414,2287.598,5372.81641,1178.840,
4294.33594,2287.598,5372.90771,1177.840,
4294.42725,2287.598,5372.99902,1177.840,
4294.51904,2286.598,5373.09082,1177.840,
4294.61035,2286.598,5373.18213,1177.840,
4294.70215,2286.598,5373.27393,1176.840,
4294.79346,2286.598,5373.36523,1176.840,
4294.88525,2286.598,5373.45703,1177.840,
4294.97656,2285.598,5373.54834,1177.840,
4295.06787,2285.598,5373.64014,1175.840,
4295.15967,2285.598,5373.73145,1176.840,
4295.25098,2284.598,5373.82275,1175.840,
4295.34277,2284.598,5373.91455,1175.840,
4295.43408,2283.598,5374.00586,1174.840,
4295.52588,2283.598,5374.09766,1174.840,
4295.61719,2283.598,5374.18896,1174.840,
4295.70850,2282.598,5374.28076,1173.840,
4295.80029,2283.598,5374.37207,1173.840,
4295.89160,2282.598,5374.46338,1172.840,
4295.98340,2282.598,5374.55518,1173.840,
4296.07471,2282.598,5374.64648,1172.840,
4296.16650,2281.598,5374.73828,1172.840,
4296.25781,2281.598,5374.82959,1172.840,
4296.34912,2281.598,5374.92139,1171.840,
4296.44092,2281.598,5375.01270,1172.840,
4296.53223,2280.598,5375.10400,1171.840,
4296.62402,2280.598,5375.19580,1171.840,
4296.71533,2279.598,5375.28711,1170.840,
4296.80713,2279.598,5375.37891,1170.840,
4296.89844,2279.598,5375.47021,1170.840,
4296.98975,2279.598,5375.56201,1170.840,
4297.08154,2279.598,5375.65332,1169.840,
4297.17285,2279.598,5375.74512,1169.840,
4297.26465,2279.598,5375.83643,1169.840,
4297.35596,2278.598,5375.92773,1169.840,
4297.44775,2278.598,5376.01953,1169.840,
4297.53906,2277.598,5376.11084,1168.840,
4297.63086,2277.598,5376.20264,1167.840,
4297.72217,2277.598,5376.29395,1167.840,
4297.81348,2276.598,5376.38574,1167.840,
4297.90527,2277.598,5376.47705,1168.840,
4297.99658,2276.598,5376.56836,1167.840,
4298.08838,2276.598,5376.66016,1166.840,
4298.17969,2276.598,5376.75146,1166.840,
4298.27148,2276.598,5376.84326,1165.840,
4298.36279,2275.598,5376.93457,1166.840,
4298.45410,2275.598,5377.02637,1165.840,
4298.54590,2275.598,5377.11768,1165.840,
4298.63721,2275.598,5377.20898,1164.840,
4298.72900,2275.598,5377.30078,1164.840,
4298.82031,2275.598,5377.39209,1164.840,
4298.91211,2274.598,5377.48389,1164.840,
4299.00342,2274.598,5377.57520,1163.840,
4299.09473,2274.598,5377.66699,1163.840,
4299.18652,2274.598,5377.75830,1162.840,
4299.27783,2273.598,5377.85010,1162.840,
4299.36963,2273.598,5377.94141,1163.840,
4299.46094,2273.598,5378.03271,1162.840,
4299.55273,2272.598,5378.12451,1162.840,
4299.64404,2272.598,5378.21582,1162.840,
4299.73584,2271.598,5378.30762,1162.840,
4299.82715,2271.598,5378.39893,1161.840,
4299.91846,2271.598,5378.49072,1160.840,
4300.01025,2271.598,5378.58203,1161.840,
4300.10156,2270.598,5378.67334,1160.840,
4300.19336,2271.598,5378.76514,1160.840,
4300.28467,2270.598,5378.85645,1159.840,
4300.37646,2270.598,5378.94824,1160.840,
4300.46777,2271.598,5379.03955,1159.840,
4300.55908,2271.598,5379.13135,1159.840,
4300.65088,2271.598,5379.22266,1158.840,
4300.74219,2271.598,5379.31396,1158.840,
4300.83398,2272.598,5379.40576,1159.840,
4300.92529,2272.598,5379.49707,1158.840,
4301.01709,2271.598,5379.58887,1157.840,
4301.10840,2272.598,5379.68018,1157.840,
4301.19971,2272.598,5379.77197,1157.840,
4301.29150,2271.598,5379.86328,1157.840,
4301.38281,2271.598,5379.95508,1156.840,
4301.47461,2270.598,5380.04639,1156.840,
4301.56592,2270.598,5380.13770,1156.840,
4301.65771,2270.598,5380.22949,1155.840,
4301.74902,2269.598,5380.32080,1155.840,
4301.84082,2268.598,5380.41260,1155.840,
4301.93213,2267.598,5380.50391,1154.840,
4302.02344,2267.598,5380.59570,1154.840,
4302.11523,2267.598,5380.68701,1154.840,
4302.20654,2266.598,5380.77832,1154.840,
4302.29834,2265.598,5380.87012,1154.840,
4302.38965,2265.598,5380.96143,1153.840,
4302.48145,2265.598,5381.05322,1153.840,
4302.57275,2264.598,5381.14453,1152.840,
4302.66406,2264.598,5381.23633,1152.840,
4302.75586,2264.598,5381.32764,1152.840,
4302.84717,2262.598,5381.41895,1152.840,
4302.93896,2262.598,5381.51074,1151.840,
4303.03027,2262.598,5381.60205,1151.840,
4303.12207,2261.598,5381.69385,1151.840,
4303.21338,2261.598,5381.78516,1151.840,
4303.30469,2260.598,5381.87695,1151.840,
4303.39648,2259.598,5381.96826,1151.840,
4303.48779,2259.598,5382.05957,1151.840,
4303.57959,2259.598,5382.15137,1150.840,
4303.67090,2259.598,5382.24268,1150.840,
4303.76270,2259.598,5382.33447,1151.840,
4303.85400,2259.598,5382.42578,1149.840,
4303.94580,2258.598,5382.51758,1149.840,
4304.03711,2258.598,5382.60889,1149.840,
4304.12842,2258.598,5382.70068,1149.840,
4304.22021,2258.598,5382.79199,1149.840,
4304.31152,2258.598,5382.88330,1148.840,
4304.40332,2258.598,5382.97510,1148.840,
4304.49463,2258.598,5383.06641,1148.840,
4304.58643,2258.598,5383.15820,1147.840,
4304.67773,2258.598,5383.24951,1147.840,
4304.76904,2257.598,5383.34131,1146.840,
4304.86084,2257.598,5383.43262,1146.840,
4304.95215,2257.598,5383.52393,1146.840,
4305.04395,2257.598,5383.61572,1145.840,
4305.13525,2257.598,5383.70703,1145.840,
4305.22705,2256.598,5383.79883,1145.840,
4305.31836,2256.598,5383.89014,1145.840,
4305.40967,2256.598,5383.98193,1144.840,
4305.50146,2255.598,5384.07324,1143.840,
4305.59277,2255.598,5384.16455,1143.840,
4305.68457,2255.598,5384.25635,1142.840,
4305.77588,2254.598,5384.34766,1141.840,
4305.86768,2254.598,5384.43945,1140.840,
4305.95898,2254.598,5384.53076,1139.840,
4306.05078,2254.598,5384.62256,1139.840,
4306.14209,2253.598,5384.71387,1138.840,
4306.23340,2253.598,5384.80566,1138.840,
4306.32520,2253.598,5384.89697,1138.840,
4306.41650,2253.598,5384.98828,1137.840,
4306.50830,2252.598,5385.08008,1137.840,
4306.59961,2252.598,5385.17139,1137.840,
4306.69141,2252.598,5385.26318,1138.840,
4306.78271,2252.598,5385.35449,1138.840,
4306.87402,2252.598,5385.44629,1137.840,
4306.96582,2251.598,5385.53760,1138.840,
4307.05713,2251.598,5385.62891,1137.840,
4307.14893,2251.598,5385.72070,1137.840,
4307.24023,2251.598,5385.81201,1138.840,
4307.33203,2250.598,5385.90381,1138.840,
4307.42334,2250.598,5385.99512,1137.840,
4307.51465,2250.598,5386.08691,1137.840,
4307.60645,2250.598,5386.17822,1137.840,
4307.69775,2250.598,5386.26953,1137.840,
4307.78955,2250.598,5386.36133,1137.840,
4307.88086,2249.598,5386.45264,1137.840,
4307.97266,2248.598,5386.54443,1136.840,
4308.06396,2248.598,5386.63574,1136.840,
4308.15576,2248.598,5386.72754,1137.840,
4308.24707,2248.598,5386.81885,1135.840,
4308.33838,2248.598,5386.91064,1135.840,
4308.43018,2247.598,5387.00195,1135.840,
4308.52148,2247.598,5387.09326,1135.840,
4308.61328,2246.598,5387.18506,1135.840,
4308.70459,2246.598,5387.27637,1135.840,
4308.79639,2246.598,5387.36816,1134.840,
4308.88770,2246.598,5387.45947,1134.840,
4308.97900,2246.598,5387.55127,1133.840,
4309.07080,2246.598,5387.64258,1133.840,
4309.16211,2245.598,5387.73389,1133.840,
4309.25391,2245.598,5387.82568,1133.840,
4309.34521,2245.598,5387.91699,1133.840,
4309.43701,2244.598,5388.00879,1132.840,
4309.52832,2244.598,5388.10010,1132.840,
4309.61963,2244.598,5388.19189,1133.840,
4309.71143,2244.598,5388.28320,1131.840,
4309.80273,2243.598,5388.37451,1131.840,
4309.89453,2243.598,5388.46631,1131.840,
4309.98584,2243.598,5388.55762,1131.840,
4310.07764,2242.598,5388.64941,1130.840,
4310.16895,2242.598,5388.74072,1130.840,
4310.26025,2242.598,5388.83252,1130.840,
4310.35205,2242.598,5388.92383,1130.840,
4310.44336,2242.598,5389.01563,1129.840,
4310.53516,2241.598,5389.10693,1129.840,
4310.62646,2242.598,5389.19824,1129.840,
4310.71826,2241.598,5389.29004,1128.840,
4310.80957,2241.598,5389.38135,1128.840,
4310.90137,2241.598,5389.47314,1128.840,
4310.99268,2240.598,5389.56445,1128.840,
4311.08398,2240.598,5389.65625,1128.840,
4311.17578,2240.598,5389.74756,1128.840,
4311.26709,2239.598,5389.83887,1127.840,
4311.35889,2239.598,5389.93066,1127.840,
4311.45020,2239.598,5390.02197,1127.840,
4311.54199,2239.598,5390.11377,1126.840,
4311.63330,2238.598,5390.20508,1125.840,
4311.72461,2238.598,5390.29688,1125.840,
4311.81641,2238.598,5390.38818,1125.840,
4311.90771,2238.598,5390.47949,1125.840,
4311.99951,2238.598,5390.57129,1124.840,
4312.09082,2237.598,5390.66260,1124.840,
4312.18262,2237.598,5390.75439,1124.840,
4312.27393,2237.598,5390.84570,1124.840,
4312.36523,2236.598,5390.93750,1124.840,
4312.45703,2236.598,5391.02881,1124.840,
4312.54834,2236.598,5391.12061,1124.840,
4312.64014,2235.598,5391.21191,1123.840,
4312.73145,2235.598,5391.30322,1123.840,
4312.82324,2235.598,5391.39502,1122.840,
4312.91455,2235.598,5391.48633,1122.840,
4313.00635,2234.598,5391.57813,1122.840,
4313.09766,2234.598,5391.66943,1122.840,
4313.18896,2234.598,5391.76123,1121.840,
4313.28076,2233.598,5391.85254,1121.840,
4313.37207,2234.598,5391.94385,1121.840,
4313.46387,2233.598,5392.03564,1120.840,
4313.55518,2233.598,5392.12695,1121.840,
4313.64697,2232.598,5392.21875,1120.840,
4313.73828,2233.598,5392.31006,1120.840,
4313.82959,2232.598,5392.40186,1119.840,
4313.92139,2232.598,5392.49316,1119.840,
4314.01270,2232.598,5392.58447,1119.840,
4314.10449,2231.598,5392.67627,1119.840,
4314.19580,2231.598,5392.76758,1119.840,
4314.28760,2231.598,5392.85938,1118.840,
4314.37891,2231.598,5392.95068,1118.840,
4314.47021,2231.598,5393.04248,1118.840,
4314.56201,2230.598,5393.13379,1118.840,
4314.65332,2230.598,5393.22510,1117.840,
4314.74512,2230.598,5393.31689,1117.840,
4314.83643,2230.598,5393.40820,1117.840,
4314.92822,2229.598,5393.50000,1116.840,
4315.01953,2228.598,5393.59131,1116.840,
4315.11133,2228.598,5393.68311,1116.840,
4315.20264,2228.598,5393.77441,1115.840,
4315.29395,2228.598,5393.86621,1115.840,
4315.38574,2228.598,5393.95752,1115.840,
4315.47705,2228.598,5394.04883,1116.840,
4315.56885,2227.598,5394.14063,1115.840,
4315.66016,2227.598,5394.23193,1114.840,
4315.75195,2227.598,5394.32373,1115.840,
4315.84326,2227.598,5394.41504,1114.840,
4315.93457,2226.598,5394.50684,1114.840,
4316.02637,2226.598,5394.59814,1113.840,
4316.11768,2226.598,5394.68945,1113.840,
4316.20947,2226.598,5394.78125,1113.840,
4316.30078,2225.598,5394.87256,1113.840,
4316.39258,2225.598,5394.96436,1112.840,
4316.48389,2225.598,5395.05566,1112.840,
4316.57520,2224.598,5395.14746,1112.840,
4316.66699,2224.598,5395.23877,1112.840,
4316.75830,2223.598,5395.33008,1111.840,
4316.85010,2223.598,5395.42188,1110.840,
4316.94141,2224.598,5395.51318,1111.840,
4317.03320,2223.598,5395.60498,1110.840,
4317.12451,2222.598,5395.69629,1110.840,
4317.21631,2222.598,5395.78809,1110.840,
4317.30762,2222.598,5395.87939,1109.840,
4317.39893,2222.598,5395.97119,1109.840,
4317.49072,2221.598,5396.06250,1109.840,
4317.58203,2221.598,5396.15381,1109.840,
4317.67383,2222.598,5396.24561,1109.840,
4317.76514,2222.598,5396.33691,1109.840,
4317.85693,2221.598,5396.42871,1108.840,
4317.94824,2221.598,5396.52002,1107.840,
4318.03955,2220.598,5396.61182,1107.840,
4318.13135,2220.598,5396.70313,1107.840,
4318.22266,2220.598,5396.79443,1107.840,
4318.31445,2219.598,5396.88623,1106.840,
4318.40576,2219.598,5396.97754,1107.840,
4318.49756,2219.598,5397.06934,1106.840,
4318.58887,2219.598,5397.16064,1106.840,
4318.68018,2218.598,5397.25244,1105.840,
4318.77197,2218.598,5397.34375,1105.840,
4318.86328,2218.598,5397.43506,1105.840,
4318.95508,2218.598,5397.52686,1104.840,
4319.04639,2217.598,5397.61816,1104.840,
4319.13818,2217.598,5397.70996,1104.840,
4319.22949,2218.598,5397.80127,1104.840,
4319.32129,2217.598,5397.89307,1103.840,
4319.41260,2217.598,5397.98438,1103.840,
4319.50391,2216.598,5398.07617,1103.840,
4319.59570,2216.598,5398.16748,1102.840,
4319.68701,2215.598,5398.25879,1103.840,
4319.77881,2215.598,5398.35059,1102.840,
4319.87012,2214.598,5398.44189,1103.840,
4319.96191,2213.598,5398.53369,1102.840,
4320.05322,2213.598,5398.62500,1101.840,
4320.14453,2213.598,5398.71680,1101.840,
4320.23633,2212.598,5398.80811,1101.840,
4320.32764,2212.598,5398.89941,1101.840,
4320.41943,2211.598,5398.99121,1101.840,
4320.51074,2211.598,5399.08252,1100.840,
4320.60254,2211.598,5399.17432,1100.840,
4320.69385,2211.598,5399.26563,1100.840,
4320.78516,2211.598,5399.35742,1099.840,
4320.87695,2211.598,5399.44873,1100.840,
4320.96826,2211.598,5399.54004,1099.840,
4321.06006,2210.598,5399.63184,1099.840,
4321.15137,2210.598,5399.72314,1099.840,
4321.24316,2210.598,5399.81494,1098.840,
4321.33447,2210.598,5399.90625,1099.840,
4321.42578,2210.598,5399.99805,1097.840,
4321.51758,2210.598,5400.08936,1097.840,
4321.60889,2210.598,5400.18115,1097.840,
4321.70068,2209.598,5400.27246,1096.840,
4321.79199,2209.598,5400.36377,1097.840,
4321.88379,2210.598,5400.45557,1096.840,
4321.97510,2210.598,5400.54688,1095.840,
4322.06689,2210.598,5400.63867,1095.840,
4322.15820,2212.598,5400.72998,1094.840,
4322.24951,2211.598,5400.82178,1094.840,
4322.34131,2210.598,5400.91309,1094.840,
4322.43262,2210.598,5401.00439,1094.840,
4322.52441,2210.598,5401.09619,1094.840,
4322.61572,2209.598,5401.18750,1094.840,
4322.70752,2209.598,5401.27930,1093.840,
4322.79883,2208.598,5401.37061,1093.840,
4322.89014,2207.598,5401.46240,1093.840,
4322.98193,2207.598,5401.55371,1093.840,
4323.07324,2207.598,5401.64502,1093.840,
4323.16504,2206.598,5401.73682,1092.840,
4323.25635,2206.598,5401.82813,1092.840,
4323.34814,2205.598,5401.91992,1092.840,
4323.43945,2205.598,5402.01123,1091.840,
4323.53076,2205.598,5402.10303,1092.840,
4323.62256,2205.598,5402.19434,1091.840,
4323.71387,2204.598,5402.28613,1091.840,
4323.80566,2204.598,5402.37744,1091.840,
4323.89697,2204.598,5402.46875,1091.840,
4323.98877,2204.598,5402.56055,1091.840,
4324.08008,2203.598,5402.65186,1090.840,
4324.17188,2203.598,5402.74365,1091.840,
4324.26318,2203.598,5402.83496,1091.840,
4324.35449,2203.598,5402.92676,1090.840,
4324.44629,2202.598,5403.01807,1089.840,
4324.53760,2202.598,5403.10938,1089.840,
4324.62939,2202.598,5403.20117,1089.840,
4324.72070,2202.598,5403.29248,1089.840,
4324.81250,2201.598,5403.38428,1088.840,
4324.90381,2201.598,5403.47559,1088.840,
4324.99512,2201.598,5403.56738,1087.840,
4325.08691,2201.598,5403.65869,1087.840,
4325.17822,2200.598,5403.75000,1086.840,
4325.27002,2200.598,5403.84180,1086.840,
4325.36133,2199.598,5403.93311,1085.840,
4325.45313,2199.598,5404.02490,1085.840,
4325.54443,2199.598,5404.11621,1086.840,
4325.63574,2199.598,5404.20801,1085.840,
4325.72754,2199.598,5404.29932,1085.840,
4325.81885,2198.598,5404.39111,1085.840,
4325.91064,2198.598,5404.48242,1085.840,
4326.00195,2198.598,5404.57373,1085.840,
4326.09375,2197.598,5404.66553,1084.840,
4326.18506,2197.598,5404.75684,1084.840,
4326.27686,2197.598,5404.84863,1084.840,
4326.36816,2197.598,5404.93994,1084.840,
4326.45947,2196.598,5405.03174,1083.840,
4326.55127,2197.598,5405.12305,1083.840,
4326.64258,2196.598,5405.21436,1083.840,
4326.73438,2195.598,5405.30615,1083.840,
4326.82568,2195.598,5405.39746,1082.840,
4326.91748,2195.598,5405.48926,1082.840,
4327.00879,2195.598,5405.58057,1081.840,
4327.10010,2194.598,5405.67236,1081.840,
4327.19189,2194.598,5405.76367,1082.840,
4327.28320,2193.598,5405.85498,1081.840,
4327.37500,2193.598,5405.94678,1081.840,
4327.46631,2193.598,5406.03809,1080.840,
4327.55811,2193.598,5406.12988,1081.840,
4327.64941,2192.598,5406.22119,1080.840,
4327.74072,2193.598,5406.31299,1079.840,
4327.83252,2192.598,5406.40430,1079.840,
4327.92383,2192.598,5406.49561,1079.840,
4328.01563,2192.598,5406.58740,1078.840,
4328.10693,2191.598,5406.67871,1078.840,
4328.19873,2191.598,5406.77051,1079.840,
4328.29004,2191.598,5406.86182,1077.840,
4328.38184,2191.598,5406.95361,1077.840,
4328.47314,2190.598,5407.04492,1077.840,
4328.56445,2190.598,5407.13672,1077.840,
4328.65625,2190.598,5407.22803,1077.840,
4328.74756,2190.598,5407.31934,1077.840,
4328.83936,2189.598,5407.41113,1077.840,
4328.93066,2189.598,5407.50244,1076.840,
4329.02246,2189.598,5407.59424,1076.840,
4329.11377,2189.598,5407.68555,1076.840,
4329.20508,2189.598,5407.77734,1075.840,
4329.29688,2189.598,5407.86865,1075.840,
4329.38818,2188.598,5407.95996,1075.840,
4329.47998,2188.598,5408.05176,1075.840,
4329.57129,2188.598,5408.14307,1074.840,
4329.66309,2187.598,5408.23486,1074.840,
4329.75439,2187.598,5408.32617,1074.840,
4329.84570,2187.598,5408.41797,1074.840,
4329.93750,2187.598,5408.50928,1073.840,
4330.02881,2186.598,5408.60059,1073.840,
4330.12061,2186.598,5408.69238,1073.840,
4330.21191,2186.598,5408.78369,1073.840,
4330.30371,2185.598,5408.87549,1073.840,
4330.39502,2186.598,5408.96680,1072.840,
4330.48682,2185.598,5409.05859,1072.840,
4330.57813,2185.598,5409.14990,1072.840,
4330.66943,2185.598,5409.24170,1071.840,
4330.76123,2184.598,5409.33301,1071.840,
4330.85254,2183.598,5409.42432,1071.840,
4330.94434,2184.598,5409.51611,1071.840,
4331.03564,2183.598,5409.60742,1070.840,
4331.12744,2183.598,5409.69922,1070.840,
4331.21875,2183.598,5409.79053,1070.840,
4331.31006,2182.598,5409.88232,1070.840,
4331.40186,2182.598,5409.97363,1069.840,
4331.49316,2182.598,5410.06494,1069.840,
4331.58496,2182.598,5410.15674,1070.840,
4331.67627,2181.598,5410.24805,1069.840,
4331.76807,2181.598,5410.33984,1069.840,
4331.85938,2181.598,5410.43115,1068.840,
4331.95068,2181.598,5410.52295,1068.840,
4332.04248,2180.598,5410.61426,1068.840,
4332.13379,2180.598,5410.70557,1067.840,
4332.22559,2180.598,5410.79736,1067.840,
4332.31689,2179.598,5410.88867,1067.840,
4332.40869,2180.598,5410.98047,1067.840,
4332.50000,2179.598,5411.07178,1067.840,
4332.59180,2179.598,5411.16357,1066.840,
4332.68311,2179.598,5411.25488,1066.840,
4332.77441,2178.598,5411.34668,1065.840,
4332.86621,2178.598,5411.43799,1065.840,
4332.95752,2178.598,5411.52930,1065.840,
4333.04932,2178.598,5411.62109,1066.840,
4333.14063,2177.598,5411.71240,1064.840,
4333.23242,2177.598,5411.80420,1065.840,
4333.32373,2176.598,5411.89551,1064.840,
4333.41504,2176.598,5411.98730,1064.840,
4333.50684,2176.598,5412.07861,1064.840,
4333.59814,2175.598,5412.16992,1064.840,
4333.68994,2175.598,5412.26172,1063.840,
4333.78125,2175.598,5412.35303,1063.840,
4333.87305,2174.598,5412.44482,1062.840,
4333.96436,2175.598,5412.53613,1063.840,
4334.05566,2174.598,5412.62793,1062.840,
4334.14746,2174.598,5412.71924,1062.840,
4334.23877,2174.598,5412.81055,1061.840,
4334.33057,2174.598,5412.90234,1061.840,
4334.42188,2173.598,5412.99365,1061.840,
4334.51367,2173.598,5413.08545,1062.840,
4334.60498,2173.598,5413.17676,1060.840,
4334.69629,2172.598,5413.26855,1060.840,
4334.78809,2172.598,5413.35986,1060.840,
4334.87939,2172.598,5413.45166,1060.840,
4334.97119,2172.598,5413.54297,1059.840,
4335.06250,2171.598,5413.63428,1060.840,
4335.15430,2171.598,5413.72607,1059.840,
4335.24561,2171.598,5413.81738,1058.840,
4335.33740,2171.598,5413.90918,1058.840,
4335.42871,2170.598,5414.00049,1058.840,
4335.52002,2170.598,5414.09229,1057.840,
4335.61182,2170.598,5414.18359,1058.840,
4335.70313,2169.598,5414.27490,1057.840,
4335.79492,2169.598,5414.36670,1057.840,
4335.88623,2169.598,5414.45801,1056.840,
4335.97803,2169.598,5414.54980,1057.840,
4336.06934,2169.598,5414.64111,1056.840,
4336.16064,2168.598,5414.73291,1057.840,
4336.25244,2168.598,5414.82422,1056.840,
4336.34375,2168.598,5414.91553,1056.840,
4336.43555,2167.598,5415.00732,1056.840,
4336.52686,2167.598,5415.09863,1055.840,
4336.61865,2167.598,5415.19043,1055.840,
4336.70996,2166.598,5415.28174,1055.840,
4336.80127,2167.598,5415.37354,1055.840,
4336.89307,2166.598,5415.46484,1054.840,
4336.98438,2166.598,5415.55664,1054.840,
4337.07617,2166.598,5415.64795,1053.840,
4337.16748,2165.598,5415.73926,1053.840,
4337.25928,2165.598,5415.83105,1053.840,
4337.35059,2165.598,5415.92236,1053.840,
4337.44238,2164.598,5416.01416,1053.840,
4337.53369,2164.598,5416.10547,1053.840,
4337.62500,2164.598,5416.19727,1053.840,
4337.71680,2164.598,5416.28857,1052.840,
4337.80811,2163.598,5416.37988,1052.840,
4337.89990,2163.598,5416.47168,1051.840,
4337.99121,2163.598,5416.56299,1051.840,
4338.08301,2162.598,5416.65479,1051.840,
4338.17432,2162.598,5416.74609,1050.840,
4338.26563,2163.598,5416.83789,1050.840,
4338.35742,2161.598,5416.92920,1050.840,
4338.44873,2161.598,5417.02051,1050.840,
4338.54053,2160.598,5417.11230,1049.840,
4338.63184,2159.598,5417.20361,1049.840,
4338.72363,2159.598,5417.29541,1049.840,
4338.81494,2158.598,5417.38672,1049.840,
4338.90625,2158.598,5417.47852,1049.840,
4338.99805,2158.598,5417.56982,1048.840,
4339.08936,2157.598,5417.66162,1047.840,
4339.18115,2157.598,5417.75293,1047.840,
4339.27246,2156.598,5417.84424,1047.840,
4339.36426,2157.598,5417.93604,1047.840,
4339.45557,2157.598,5418.02734,1047.840,
4339.54736,2156.598,5418.11914,1046.840,
4339.63867,2156.598,5418.21045,1047.840,
4339.72998,2156.598,5418.30225,1046.840,
4339.82178,2156.598,5418.39355,1046.840,
4339.91309,2156.598,5418.48486,1047.840,
4340.00488,2156.598,5418.57666,1047.840,
4340.09619,2156.598,5418.66797,1047.840,
4340.18799,2156.598,5418.75977,1047.840,
4340.27930,2156.598,5418.85107,1048.840,
4340.37061,2156.598,5418.94287,1048.840,
4340.46240,2156.598,5419.03418,1048.840,
4340.55371,2155.598,5419.12549,1047.840,
4340.64551,2155.598,5419.21729,1046.840,
4340.73682,2155.598,5419.30859,1046.840,
4340.82861,2155.598,5419.40039,1046.840,
4340.91992,2155.598,5419.49170,1045.840,
4341.01123,2156.598,5419.58350,1045.840,
4341.10303,2155.598,5419.67480,1044.840,
4341.19434,2157.598,5419.76611,1044.840,
4341.28613,2156.598,5419.85791,1043.840,
4341.37744,2156.598,5419.94922,1043.840,
4341.46924,2156.598,5420.04102,1042.840,
4341.56055,2156.598,5420.13232,1041.840,
4341.65234,2156.598,5420.22412,1042.840,
4341.74365,2155.598,5420.31543,1041.840,
4341.83496,2155.598,5420.40723,1041.840,
4341.92676,2154.598,5420.49854,1040.840,
4342.01807,2154.598,5420.58984,1040.840,
4342.10986,2153.598,5420.68164,1040.840,
4342.20117,2152.598,5420.77295,1040.840,
4342.29297,2152.598,5420.86475,1040.840,
4342.38428,2151.598,5420.95605,1040.840,
4342.47559,2152.598,5421.04785,1040.840,
4342.56738,2151.598,5421.13916,1040.840,
4342.65869,2151.598,5421.23047,1039.840,
4342.75049,2150.598,5421.32227,1038.840,
4342.84180,2149.598,5421.41357,1039.840,
4342.93359,2148.598,5421.50537,1038.840,
4343.02490,2149.598,5421.59668,1037.840,
4343.11621,2148.598,5421.68848,1037.840,
4343.20801,2148.598,5421.77979,1036.840,
4343.29932,2148.598,5421.87109,1037.840,
4343.39111,2147.598,5421.96289,1036.840,
4343.48242,2147.598,5422.05420,1035.840,
4343.57422,2146.598,5422.14600,1035.840,
4343.66553,2146.598,5422.23730,1035.840,
4343.75732,2146.598,5422.32910,1034.840,
4343.84863,2146.598,5422.42041,1034.840,
4343.93994,2146.598,5422.51221,1034.840,
4344.03174,2145.598,5422.60352,1034.840,
4344.12305,2145.598,5422.69482,1033.840,
4344.21484,2145.598,5422.78662,1033.840,
4344.30615,2145.598,5422.87793,1033.840,
4344.39795,2144.598,5422.96973,1033.840,
4344.48926,2144.598,5423.06104,1033.840,
4344.58057,2143.598,5423.15283,1032.840,
4344.67236,2144.598,5423.24414,1032.840,
4344.76367,2144.598,5423.33545,1033.840,
4344.85547,2143.598,5423.42725,1031.840,
4344.94678,2142.598,5423.51855,1031.840,
4345.03857,2142.598,5423.61035,1031.840,
4345.12988,2142.598,5423.70166,1031.840,
4345.22119,2141.598,5423.79346,1031.840,
4345.31299,2141.598,5423.88477,1030.840,
4345.40430,2141.598,5423.97607,1030.840,
4345.49609,2141.598,5424.06787,1030.840,
4345.58740,2141.598,5424.15918,1029.840,
4345.67920,2140.598,5424.25098,1030.840,
4345.77051,2140.598,5424.34229,1028.840,
4345.86182,2140.598,5424.43408,1029.840,
4345.95361,2139.598,5424.52539,1028.840,
4346.04492,2139.598,5424.61719,1028.840,
4346.13672,2139.598,5424.70850,1028.840,
4346.22803,2139.598,5424.79980,1028.840,
4346.31982,2139.598,5424.89160,1028.840,
4346.41113,2138.598,5424.98291,1027.840,
4346.50293,2137.598,5425.07471,1027.840,
4346.59424,2138.598,5425.16602,1027.840,
4346.68555,2137.598,5425.25781,1026.840,
4346.77734,2137.598,5425.34912,1026.840,
4346.86865,2136.598,5425.44043,1026.840,
4346.96045,2136.598,5425.53223,1025.840,
4347.05176,2137.598,5425.62354,1025.840,
4347.14355,2136.598,5425.71533,1025.840,
4347.23486,2136.598,5425.80664,1025.840,
4347.32617,2135.598,5425.89844,1024.840,
4347.41797,2135.598,5425.98975,1024.840,
4347.50928,2135.598,5426.08105,1024.840,
4347.60107,2134.598,5426.17285,1024.840,
4347.69238,2134.598,5426.26416,1024.840,
4347.78418,2134.598,5426.35596,1024.840,
4347.87549,2134.598,5426.44727,1023.840,
4347.96680,2133.598,5426.53906,1023.840,
4348.05859,2134.598,5426.63037,1022.840,
4348.14990,2133.598,5426.72217,1022.840,
4348.24170,2133.598,5426.81348,1022.840,
4348.33301,2133.598,5426.90479,1021.840,
4348.42480,2132.598,5426.99658,1021.840,
4348.51611,2132.598,5427.08789,1021.840,
4348.60791,2132.598,5427.17969,1021.840,
4348.69922,2132.598,5427.27100,1020.840,
4348.79053,2131.598,5427.36279,1021.840,
4348.88232,2131.598,5427.45410,1019.840,
4348.97363,2131.598,5427.54541,1020.840,
4349.06543,2131.598,5427.63721,1020.840,
4349.15674,2130.598,5427.72852,1019.840,
4349.24854,2130.598,5427.82031,1019.840,
4349.33984,2130.598,5427.91162,1019.840,
4349.43115,2129.598,5428.00342,1019.840,
4349.52295,2129.598,5428.09473,1019.840,
4349.61426,2129.598,5428.18604,1018.840,
4349.70605,2129.598,5428.27783,1018.840,
4349.79736,2128.598,5428.36914,1017.840,
4349.88916,2128.598,5428.46094,1018.840,
4349.98047,2129.598,5428.55225,1017.840,
4350.07178,2127.598,5428.64404,1017.840,
4350.16357,2127.598,5428.73535,1017.840,
4350.25488,2127.598,5428.82715,1016.840,
4350.34668,2126.598,5428.91846,1016.840,
4350.43799,2126.598,5429.00977,1016.840,
4350.52979,2126.598,5429.10156,1015.840,
4350.62109,2126.598,5429.19287,1015.840,
4350.71289,2126.598,5429.28467,1015.840,
4350.80420,2125.598,5429.37598,1015.840,
4350.89551,2125.598,5429.46777,1015.840,
4350.98730,2124.598,5429.55908,1014.840,
4351.07861,2124.598,5429.65039,1014.840,
4351.17041,2125.598,5429.74219,1014.840,
4351.26172,2124.598,5429.83350,1013.840,
4351.35352,2124.598,5429.92529,1014.840,
4351.44482,2124.598,5430.01660,1013.840,
4351.53613,2123.598,5430.10840,1012.840,
4351.62793,2123.598,5430.19971,1012.840,
4351.71924,2123.598,5430.29102,1012.840,
4351.81104,2122.598,5430.38281,1012.840,
4351.90234,2122.598,5430.47412,1011.840,
4351.99414,2122.598,5430.56592,1011.840,
4352.08545,2121.598,5430.65723,1012.840,
4352.17676,2121.598,5430.74902,1011.840,
4352.26855,2121.598,5430.84033,1011.840,
4352.35986,2121.598,5430.93164,1010.840,
4352.45166,2120.598,5431.02344,1011.840,
4352.54297,2120.598,5431.11475,1010.840,
4352.63477,2120.598,5431.20654,1010.840,
4352.72607,2119.598,5431.29785,1009.840,
4352.81787,2119.598,5431.38965,1009.840,
4352.90918,2120.598,5431.48096,1009.840,
4353.00049,2119.598,5431.57275,1009.840,
4353.09229,2118.598,5431.66406,1009.840,
4353.18359,2118.598,5431.75537,1008.840,
4353.27539,2118.598,5431.84717,1008.840,
4353.36670,2117.598,5431.93848,1008.840,
4353.45850,2117.598,5432.03027,1008.840,
4353.54980,2117.598,5432.12158,1008.840,
4353.64111,2117.598,5432.21338,1007.840,
4353.73291,2116.598,5432.30469,1007.840,
4353.82422,2116.598,5432.39600,1007.840,
4353.91602,2116.598,5432.48779,1007.840,
4354.00732,2116.598,5432.57910,1006.840,
4354.09912,2116.598,5432.67090,1006.840,
4354.19043,2115.598,5432.76221,1006.840,
4354.28174,2115.598,5432.85400,1005.840,
4354.37354,2115.598,5432.94531,1005.840,
4354.46484,2115.598,5433.03662,1005.840,
4354.55664,2114.598,5433.12842,1005.840,
4354.64795,2114.598,5433.21973,1004.840,
4354.73975,2113.598,5433.31152,1004.840,
4354.83105,2113.598,5433.40283,1004.840,
4354.92285,2113.598,5433.49463,1003.840,
4355.01416,2113.598,5433.58594,1004.840,
4355.10547,2113.598,5433.67773,1003.840,
4355.19727,2112.598,5433.76904,1003.840,
4355.28857,2112.598,5433.86035,1003.840,
4355.38037,2112.598,5433.95215,1003.840,
4355.47168,2111.598,5434.04346,1002.840,
4355.56348,2111.598,5434.13525,1002.840,
4355.65479,2111.598,5434.22656,1002.840,
4355.74609,2110.598,5434.31836,1001.840,
4355.83789,2111.598,5434.40967,1001.840,
4355.92920,2110.598,5434.50098,1001.840,
4356.02100,2109.598,5434.59277,1001.840,
4356.11230,2109.598,5434.68408,1000.840,
4356.20410,2109.598,5434.77588,1000.840,
4356.29541,2108.598,5434.86719,1000.840,
4356.38672,2108.598,5434.95898,1000.840,
4356.47852,2109.598,5435.05029,1000.840,
4356.56982,2108.598,5435.14160,1000.840,
4356.66162,2108.598,5435.23340,999.840,
4356.75293,2107.598,5435.32471,999.840,
4356.84473,2107.598,5435.41650,999.840,
4356.93604,2107.598,5435.50781,998.840,
4357.02783,2107.598,5435.59961,998.840,
4357.11914,2106.598,5435.69092,997.840,
4357.21045,2106.598,5435.78271,997.840,
4357.30225,2105.598,5435.87402,997.840,
4357.39355,2105.598,5435.96533,997.840,
4357.48535,2104.598,5436.05713,996.840,
4357.57666,2103.598,5436.14844,996.840,
4357.66846,2103.598,5436.24023,996.840,
4357.75977,2102.598,5436.33154,996.840,
4357.85107,2102.598,5436.42334,995.840,
4357.94287,2101.598,5436.51465,995.840,
4358.03418,2102.598,5436.60596,995.840,
4358.12598,2102.598,5436.69775,995.840,
4358.21729,2101.598,5436.78906,995.840,
4358.30908,2101.598,5436.88086,994.840,
4358.40039,2101.598,5436.97217,994.840,
4358.49170,2101.598,5437.06396,994.840,
4358.58350,2101.598,5437.15527,993.840,
4358.67480,2101.598,5437.24658,993.840,
4358.76660,2100.598,5437.33838,993.840,
4358.85791,2100.598,5437.42969,993.840,
4358.94971,2101.598,5437.52148,992.840,
4359.04102,2100.598,5437.61279,992.840,
4359.13232,2100.598,5437.70459,992.840,
4359.22412,2100.598,5437.79590,991.840,
4359.31543,2099.598,5437.88770,991.840,
4359.40723,2099.598,5437.97900,992.840,
4359.49854,2099.598,5438.07031,991.840,
4359.59033,2099.598,5438.16211,990.840,
4359.68164,2099.598,5438.25342,990.840,
4359.77344,2099.598,5438.34521,990.840,
4359.86475,2099.598,5438.43652,989.840,
4359.95605,2098.598,5438.52832,989.840,
4360.04785,2098.598,5438.61963,988.840,
4360.13916,2099.598,5438.71094,987.840,
4360.23096,2099.598,5438.80273,987.840,
4360.32227,2098.598,5438.89404,986.840,
4360.41406,2098.598,5438.98584,986.840,
4360.50537,2097.598,5439.07715,986.840,
4360.59668,2097.598,5439.16895,986.840,
4360.68848,2097.598,5439.26025,986.840,
4360.77979,2097.598,5439.35156,985.840,
4360.87158,2097.598,5439.44336,986.840,
4360.96289,2096.598,5439.53467,985.840,
4361.05469,2096.598,5439.62646,985.840,
4361.14600,2095.598,5439.71777,986.840,
4361.23730,2095.598,5439.80957,985.840,
4361.32910,2095.598,5439.90088,985.840,
4361.42041,2094.598,5439.99268,985.840,
4361.51221,2093.598,5440.08398,985.840,
4361.60352,2094.598,5440.17529,984.840,
4361.69531,2094.598,5440.26709,985.840,
4361.78662,2093.598,5440.35840,984.840,
4361.87842,2093.598,5440.45020,984.840,
4361.96973,2092.598,5440.54150,983.840,
4362.06104,2092.598,5440.63330,982.840,
4362.15283,2091.598,5440.72461,981.840,
4362.24414,2092.598,5440.81592,980.840,
4362.33594,2091.598,5440.90771,980.840,
4362.42725,2090.598,5440.99902,979.840,
4362.51904,2090.598,5441.09082,979.840,
4362.61035,2090.598,5441.18213,979.840,
4362.70166,2089.598,5441.27393,978.840,
4362.79346,2090.598,5441.36523,978.840,
4362.88477,2089.598,5441.45654,978.840,
4362.97656,2089.598,5441.54834,978.840,
4363.06787,2089.598,5441.63965,979.840,
4363.15967,2089.598,5441.73145,978.840,
4363.25098,2087.598,5441.82275,978.840,
4363.34229,2088.598,5441.91455,979.840,
4363.43408,2087.598,5442.00586,978.840,
4363.52539,2086.598,5442.09766,978.840,
4363.61719,2087.598,5442.18896,978.840,
4363.70850,2087.598,5442.28027,978.840,
4363.80029,2086.598,5442.37207,979.840,
4363.89160,2086.598,5442.46338,979.840,
4363.98340,2086.598,5442.55518,979.840,
4364.07471,2085.598,5442.64648,978.840,
4364.16602,2085.598,5442.73828,978.840,
4364.25781,2085.598,5442.82959,978.840,
4364.34912,2085.598,5442.92090,978.840,
4364.44092,2084.598,5443.01270,978.840,
4364.53223,2084.598,5443.10400,977.840,
4364.62402,2084.598,5443.19580,977.840,
4364.71533,2084.598,5443.28711,977.840,
4364.80664,2083.598,5443.37891,977.840,
4364.89844,2083.598,5443.47021,976.840,
4364.98975,2083.598,5443.56152,975.840,
4365.08154,2082.598,5443.65332,976.840,
4365.17285,2083.598,5443.74463,976.840,
4365.26465,2082.598,5443.83643,976.840,
4365.35596,2082.598,5443.92773,975.840,
4365.44727,2082.598,5444.01953,975.840,
4365.53906,2081.598,5444.11084,975.840,
4365.63037,2081.598,5444.20215,975.840,
4365.72217,2081.598,5444.29395,974.840,
4365.81348,2081.598,5444.38525,974.840,
4365.90527,2080.598,5444.47705,974.840,
4365.99658,2080.598,5444.56836,973.840,
4366.08838,2080.598,5444.66016,973.840,
4366.17969,2079.598,5444.75146,973.840,
4366.27100,2079.598,5444.84326,973.840,
4366.36279,2079.598,5444.93457,973.840,
4366.45410,2078.598,5445.02588,972.840,
4366.54590,2078.598,5445.11768,972.840,
4366.63721,2078.598,5445.20898,972.840,
4366.72900,2078.598,5445.30078,972.840,
4366.82031,2077.598,5445.39209,971.840,
4366.91162,2077.598,5445.48389,971.840,
4367.00342,2077.598,5445.57520,971.840,
4367.09473,2076.598,5445.66650,971.840,
4367.18652,2077.598,5445.75830,971.840,
4367.27783,2076.598,5445.84961,970.840,
4367.36963,2075.598,5445.94141,970.840,
4367.46094,2075.598,5446.03271,970.840,
4367.55225,2075.598,5446.12451,969.840,
4367.64404,2075.598,5446.21582,969.840,
4367.73535,2074.598,5446.30713,969.840,
4367.82715,2074.598,5446.39893,969.840,
4367.91846,2074.598,5446.49023,968.840,
4368.01025,2073.598,5446.58203,968.840,
4368.10156,2074.598,5446.67334,968.840,
4368.19336,2073.598,5446.76514,968.840,
4368.28467,2073.598,5446.85645,967.840,
4368.37598,2073.598,5446.94824,967.840,
4368.46777,2073.598,5447.03955,967.840,
4368.55908,2072.598,5447.13086,967.840,
4368.65088,2072.598,5447.22266,966.840,
4368.74219,2072.598,5447.31396,966.840,
4368.83398,2071.598,5447.40576,966.840,
4368.92529,2071.598,5447.49707,966.840,
4369.01660,2071.598,5447.58887,966.840,
4369.10840,2070.598,5447.68018,965.840,
4369.19971,2070.598,5447.77148,965.840,
4369.29150,2070.598,5447.86328,965.840,
4369.38281,2070.598,5447.95459,965.840,
4369.47461,2069.598,5448.04639,964.840,
4369.56592,2069.598,5448.13770,964.840,
4369.65723,2069.598,5448.22949,964.840,
4369.74902,2068.598,5448.32080,964.840,
4369.84033,2068.598,5448.41211,963.840,
4369.93213,2068.598,5448.50391,963.840,
4370.02344,2067.598,5448.59521,963.840,
4370.11523,2067.598,5448.68701,962.840,
4370.20654,2067.598,5448.77832,962.840,
4370.29834,2067.598,5448.87012,962.840,
4370.38965,2066.598,5448.96143,961.840,
4370.48096,2067.598,5449.05322,961.840,
4370.57275,2066.598,5449.14453,961.840,
4370.66406,2065.598,5449.23584,961.840,
4370.75586,2065.598,5449.32764,960.840,
4370.84717,2065.598,5449.41895,961.840,
4370.93896,2065.598,5449.51074,960.840,
4371.03027,2065.598,5449.60205,960.840,
4371.12158,2065.598,5449.69385,960.840,
4371.21338,2064.598,5449.78516,959.840,
4371.30469,2064.598,5449.87646,960.840,
4371.39648,2063.598,5449.96826,959.840,
4371.48779,2063.598,5450.05957,959.840,
4371.57959,2063.598,5450.15137,959.840,
4371.67090,2063.598,5450.24268,958.840,
4371.76221,2062.598,5450.33447,959.840,
4371.85400,2062.598,5450.42578,958.840,
4371.94531,2062.598,5450.51709,957.840,
4372.03711,2062.598,5450.60889,957.840,
4372.12842,2061.598,5450.70020,957.840,
4372.22021,2061.598,5450.79199,957.840,
4372.31152,2061.598,5450.88330,956.840,
4372.40283,2060.598,5450.97510,957.840,
4372.49463,2060.598,5451.06641,956.840,
4372.58594,2060.598,5451.15820,956.840,
4372.67773,2059.598,5451.24951,956.840,
4372.76904,2060.598,5451.34082,955.840,
4372.86084,2059.598,5451.43262,955.840,
4372.95215,2059.598,5451.52393,955.840,
4373.04395,2058.598,5451.61572,955.840,
4373.13525,2058.598,5451.70703,954.840,
4373.22656,2058.598,5451.79883,954.840,
4373.31836,2058.598,5451.89014,954.840,
4373.40967,2058.598,5451.98145,953.840,
4373.50146,2057.598,5452.07324,953.840,
4373.59277,2057.598,5452.16455,953.840,
4373.68457,2057.598,5452.25635,953.840,
4373.77588,2056.598,5452.34766,953.840,
4373.86719,2056.598,5452.43945,953.840,
4373.95898,2056.598,5452.53076,952.840,
4374.05029,2055.598,5452.62207,952.840,
4374.14209,2055.598,5452.71387,951.840,
4374.23340,2055.598,5452.80518,952.840,
4374.32520,2055.598,5452.89697,951.840,
4374.41650,2054.598,5452.98828,951.840,
4374.50781,2054.598,5453.08008,951.840,
4374.59961,2054.598,5453.17139,950.840,
4374.69092,2054.598,5453.26318,950.840,
4374.78271,2053.598,5453.35449,950.840,
4374.87402,2054.598,5453.44580,950.840,
4374.96582,2053.598,5453.53760,949.840,
4375.05713,2053.598,5453.62891,949.840,
4375.14893,2052.598,5453.72070,948.840,
4375.24023,2052.598,5453.81201,948.840,
4375.33154,2051.598,5453.90381,949.840,
4375.42334,2051.598,5453.99512,948.840,
4375.51465,2051.598,5454.08643,949.840,
4375.60645,2051.598,5454.17822,948.840,
4375.69775,2051.598,5454.26953,948.840,
4375.78955,2050.598,5454.36133,947.840,
4375.88086,2050.598,5454.45264,947.840,
4375.97217,2050.598,5454.54443,948.840,
4376.06396,2049.598,5454.63574,946.840,
4376.15527,2049.598,5454.72705,946.840,
4376.24707,2049.598,5454.81885,946.840,
4376.33838,2050.598,5454.91016,946.840,
4376.43018,2049.598,5455.00195,945.840,
4376.52148,2049.598,5455.09326,946.840,
4376.61279,2049.598,5455.18506,946.840,
4376.70459,2048.598,5455.27637,945.840,
4376.79590,2048.598,5455.36816,945.840,
4376.88770,2048.598,5455.45947,945.840,
4376.97900,2047.598,5455.55078,945.840,
4377.07080,2047.598,5455.64258,944.840,
4377.16211,2047.598,5455.73389,943.840,
4377.25391,2046.598,5455.82568,943.840,
4377.34521,2046.598,5455.91699,943.840,
4377.43652,2046.598,5456.00879,943.840,
4377.52832,2045.598,5456.10010,943.840,
4377.61963,2045.598,5456.19141,942.840,
4377.71143,2044.598,5456.28320,942.840,
4377.80273,2045.598,5456.37451,942.840,
4377.89453,2044.598,5456.46631,941.840,
4377.98584,2044.598,5456.55762,941.840,
4378.07715,2043.598,5456.64941,941.840,
4378.16895,2042.598,5456.74072,941.840,
4378.26025,2042.598,5456.83203,940.840,
4378.35205,2041.598,5456.92383,940.840,
4378.44336,2041.598,5457.01514,941.840,
4378.53516,2039.598,5457.10693,940.840,
4378.62646,2039.598,5457.19824,939.840,
4378.71777,2039.598,5457.29004,939.840,
4378.80957,2038.598,5457.38135,939.840,
4378.90088,2038.598,5457.47266,939.840,
4378.99268,2038.598,5457.56445,938.840,
4379.08398,2037.598,5457.65576,938.840,
4379.17578,2037.598,5457.74756,938.840,
4379.26709,2038.598,5457.83887,938.840,
4379.35889,2037.598,5457.93066,938.840,
4379.45020,2037.598,5458.02197,937.840,
4379.54150,2037.598,5458.11377,937.840,
4379.63330,2037.598,5458.20508,937.840,
4379.72461,2036.598,5458.29639,937.840,
4379.81641,2037.598,5458.38818,937.840,
4379.90771,2037.598,5458.47949,936.840,
4379.99951,2036.598,5458.57129,936.840,
4380.09082,2036.598,5458.66260,935.840,
4380.18213,2035.598,5458.75439,935.840,
4380.27393,2035.598,5458.84570,935.840,
4380.36523,2036.598,5458.93701,933.840,
4380.45703,2035.598,5459.02881,934.840,
4380.54834,2035.598,5459.12012,933.840,
4380.64014,2035.598,5459.21191,933.840,
4380.73145,2035.598,5459.30322,932.840,
4380.82275,2035.598,5459.39502,932.840,
4380.91455,2034.598,5459.48633,932.840,
4381.00586,2034.598,5459.57764,932.840,
4381.09766,2034.598,5459.66943,931.840,
4381.18896,2034.598,5459.76074,931.840,
4381.28076,2033.598,5459.85254,931.840,
4381.37207,2033.598,5459.94385,931.840,
4381.46387,2033.598,5460.03564,931.840,
4381.55518,2033.598,5460.12695,931.840,
4381.64648,2033.598,5460.21875,931.840,
4381.73828,2032.598,5460.31006,931.840,
4381.82959,2031.598,5460.40137,931.840,
4381.92139,2031.598,5460.49316,930.840,
4382.01270,2031.598,5460.58447,931.840,
4382.10449,2031.598,5460.67627,930.840,
4382.19580,2031.598,5460.76758,930.840,
4382.28711,2030.598,5460.85938,929.840,
4382.37891,2030.598,5460.95068,929.840,
4382.47021,2030.598,5461.04199,929.840,
4382.56201,2030.598,5461.13379,928.840,
4382.65332,2029.598,5461.22510,928.840,
4382.74512,2029.598,5461.31689,927.840,
4382.83643,2029.598,5461.40820,927.840,
4382.92773,2028.598,5461.50000,927.840,
4383.01953,2027.598,5461.59131,927.840,
4383.11084,2027.598,5461.68262,926.840,
4383.20264,2027.598,5461.77441,926.840,
4383.29395,2027.598,5461.86572,925.840,
4383.38574,2027.598,5461.95752,926.840,
4383.47705,2027.598,5462.04883,925.840,
4383.56836,2026.598,5462.14063,926.840,
4383.66016,2026.598,5462.23193,925.840,
4383.75146,2026.598,5462.32373,925.840,
4383.84326,2026.598,5462.41504,925.840,
4383.93457,2025.598,5462.50635,925.840,
4384.02637,2025.598,5462.59814,925.840,
4384.11768,2025.598,5462.68945,925.840,
4384.20947,2025.598,5462.78125,924.840,
4384.30078,2025.598,5462.87256,925.840,
4384.39209,2024.598,5462.96436,924.840,
4384.48389,2023.598,5463.05566,923.840,
4384.57520,2023.598,5463.14697,924.840,
4384.66699,2023.598,5463.23877,923.840,
4384.75830,2022.598,5463.33008,923.840,
4384.85010,2022.598,5463.42188,923.840,
4384.94141,2022.598,5463.51318,922.840,
4385.03271,2022.598,5463.60498,922.840,
4385.12451,2021.598,5463.69629,922.840,
4385.21582,2021.598,5463.78760,921.840,
4385.30762,2020.598,5463.87939,922.840,
4385.39893,2020.598,5463.97070,921.840,
4385.49072,2020.598,5464.06250,921.840,
4385.58203,2020.598,5464.15381,921.840,
4385.67334,2020.598,5464.24561,921.840,
4385.76514,2019.598,5464.33691,921.840,
4385.85645,2019.598,5464.42871,920.840,
4385.94824,2019.598,5464.52002,920.840,
4386.03955,2019.598,5464.61133,920.840,
4386.13135,2018.598,5464.70313,919.840,
4386.22266,2018.598,5464.79443,919.840,
4386.31445,2018.598,5464.88623,919.840,
4386.40576,2018.598,5464.97754,919.840,
4386.49707,2017.598,5465.06934,918.840,
4386.58887,2018.598,5465.16064,918.840,
4386.68018,2017.598,5465.25195,918.840,
4386.77197,2017.598,5465.34375,917.840,
4386.86328,2016.598,5465.43506,918.840,
4386.95508,2016.598,5465.52686,917.840,
4387.04639,2016.598,5465.61816,917.840,
4387.13770,2015.598,5465.70996,917.840,
4387.22949,2015.598,5465.80127,917.840,
4387.32080,2014.598,5465.89258,916.840,
4387.41260,2014.598,5465.98438,916.840,
4387.50391,2014.598,5466.07568,916.840,
4387.59570,2013.598,5466.16748,916.840,
4387.68701,2013.598,5466.25879,915.840,
4387.77832,2013.598,5466.35059,915.840,
4387.87012,2013.598,5466.44189,915.840,
4387.96143,2013.598,5466.53369,915.840,
4388.05322,2013.598,5466.62500,914.840,
4388.14453,2012.598,5466.71631,914.840,
4388.23633,2012.598,5466.80811,914.840,
4388.32764,2012.598,5466.89941,913.840,
4388.41943,2011.598,5466.99121,913.840,
4388.51074,2011.598,5467.08252,913.840,
4388.60205,2010.598,5467.17432,913.840,
4388.69385,2010.598,5467.26563,913.840,
4388.78516,2010.598,5467.35693,913.840,
4388.87695,2010.598,5467.44873,912.840,
4388.96826,2009.598,5467.54004,912.840,
4389.06006,2009.598,5467.63184,911.840,
4389.15137,2009.598,5467.72314,911.840,
4389.24268,2009.598,5467.81494,911.840,
4389.33447,2008.598,5467.90625,911.840,
4389.42578,2008.598,5467.99756,911.840,
4389.51758,2008.598,5468.08936,910.840,
4389.60889,2007.598,5468.18066,910.840,
4389.70068,2008.598,5468.27246,910.840,
4389.79199,2007.598,5468.36377,909.840,
4389.88330,2006.598,5468.45557,909.840,
4389.97510,2007.598,5468.54688,909.840,
4390.06641,2006.598,5468.63818,909.840,
4390.15820,2006.598,5468.72998,909.840,
4390.24951,2005.598,5468.82129,908.840,
4390.34131,2005.598,5468.91309,908.840,
4390.43262,2005.598,5469.00439,908.840,
4390.52441,2005.598,5469.09619,908.840,
4390.61572,2005.598,5469.18750,907.840,
4390.70703,2005.598,5469.27930,907.840,
4390.79883,2004.598,5469.37061,907.840,
4390.89014,2004.598,5469.46191,907.840,
4390.98193,2004.598,5469.55371,906.840,
4391.07324,2003.598,5469.64502,906.840,
4391.16504,2003.598,5469.73682,906.840,
4391.25635,2003.598,5469.82813,906.840,
4391.34766,2002.598,5469.91992,905.840,
4391.43945,2002.598,5470.01123,905.840,
4391.53076,2002.598,5470.10254,905.840,
4391.62256,2001.598,5470.19434,905.840,
4391.71387,2001.598,5470.28564,905.840,
4391.80566,2001.598,5470.37744,905.840,
4391.89697,2001.598,5470.46875,904.840,
4391.98828,2000.598,5470.56055,904.840,
4392.08008,2000.598,5470.65186,904.840,
4392.17139,2000.598,5470.74316,903.840,
4392.26318,2000.598,5470.83496,903.840,
4392.35449,1999.598,5470.92627,903.840,
4392.44629,1999.598,5471.01807,903.840,
4392.53760,1999.598,5471.10938,902.840,
4392.62939,1999.598,5471.20117,902.840,
4392.72070,1999.598,5471.29248,902.840,
4392.81201,1998.598,5471.38428,901.840,
4392.90381,1997.598,5471.47559,902.840,
4392.99512,1998.598,5471.56689,901.840,
4393.08691,1997.598,5471.65869,902.840,
4393.17822,1996.598,5471.75000,901.840,
4393.27002,1996.598,5471.84180,900.840,
4393.36133,1996.598,5471.93311,900.840,
4393.45264,1996.598,5472.02490,900.840,
4393.54443,1996.598,5472.11621,899.840,
4393.63574,1996.598,5472.20752,900.840,
4393.72754,1995.598,5472.29932,900.840,
4393.81885,1995.598,5472.39063,899.840,
4393.91064,1995.598,5472.48242,899.840,
4394.00195,1995.598,5472.57373,899.840,
4394.09326,1994.598,5472.66553,898.840,
4394.18506,1994.598,5472.75684,898.840,
4394.27637,1994.598,5472.84814,898.840,
4394.36816,1992.598,5472.93994,898.840,
4394.45947,1993.598,5473.03125,897.840,
4394.55127,1993.598,5473.12305,898.840,
4394.64258,1992.598,5473.21436,897.840,
4394.73438,1992.598,5473.30615,896.840,
4394.82568,1992.598,5473.39746,897.840,
4394.91699,1991.598,5473.48926,896.840,
4395.00879,1991.598,5473.58057,896.840,
4395.10010,1992.598,5473.67188,896.840,
4395.19189,1992.598,5473.76367,896.840,
4395.28320,1992.598,5473.85498,895.840,
4395.37500,1993.598,5473.94678,895.840,
4395.46631,1992.598,5474.03809,895.840,
4395.55762,1993.598,5474.12988,894.840,
4395.64941,1992.598,5474.22119,894.840,
4395.74072,1992.598,5474.31250,893.840,
4395.83252,1991.598,5474.40430,893.840,
4395.92383,1991.598,5474.49561,893.840,
4396.01563,1991.598,5474.58740,893.840,
4396.10693,1990.598,5474.67871,893.840,
4396.19824,1989.598,5474.77051,893.840,
4396.29004,1989.598,5474.86182,892.840,
4396.38135,1988.598,5474.95313,892.840,
4396.47314,1988.598,5475.04492,892.840,
4396.56445,1988.598,5475.13623,891.840,
4396.65625,1987.598,5475.22803,891.840,
4396.74756,1986.598,5475.31934,891.840,
4396.83887,1987.598,5475.41113,891.840,
4396.93066,1986.598,5475.50244,890.840,
4397.02197,1986.598,5475.59424,890.840,
4397.11377,1985.598,5475.68555,889.840,
4397.20508,1984.598,5475.77686,890.840,
4397.29688,1984.598,5475.86865,890.840,
4397.38818,1984.598,5475.95996,889.840,
4397.47998,1983.598,5476.05176,889.840,
4397.57129,1982.598,5476.14307,889.840,
4397.66260,1981.598,5476.23486,889.840,
4397.75439,1981.598,5476.32617,888.840,
4397.84570,1981.598,5476.41748,888.840,
4397.93750,1980.598,5476.50928,888.840,
4398.02881,1981.598,5476.60059,888.840,
4398.12061,1980.598,5476.69238,888.840,
4398.21191,1980.598,5476.78369,887.840,
4398.30322,1981.598,5476.87549,887.840,
4398.39502,1980.598,5476.96680,887.840,
4398.48633,1980.598,5477.05811,886.840,
4398.57813,1980.598,5477.14990,886.840,
4398.66943,1980.598,5477.24121,886.840,
4398.76123,1979.598,5477.33301,886.840,
4398.85254,1979.598,5477.42432,886.840,
4398.94385,1979.598,5477.51611,885.840,
4399.03564,1979.598,5477.60742,885.840,
4399.12695,1979.598,5477.69922,885.840,
4399.21875,1978.598,5477.79053,885.840,
4399.31006,1978.598,5477.88184,884.840,
4399.40186,1977.598,5477.97363,884.840,
4399.49316,1977.598,5478.06494,884.840,
4399.58496,1977.598,5478.15674,884.840,
4399.67627,1977.598,5478.24805,884.840,
4399.76758,1977.598,5478.33984,883.840,
4399.85938,1976.598,5478.43115,883.840,
4399.95068,1976.598,5478.52246,883.840,
4400.04248,1976.598,5478.61426,882.840,
4400.13379,1976.598,5478.70557,882.840,
4400.22559,1976.598,5478.79736,882.840,
4400.31689,1975.598,5478.88867,882.840,
4400.40820,1975.598,5478.98047,882.840,
4400.50000,1975.598,5479.07178,881.840,
4400.59131,1974.598,5479.16309,881.840,
4400.68311,1974.598,5479.25488,881.840,
4400.77441,1974.598,5479.34619,881.840,
4400.86621,1973.598,5479.43799,881.840,
4400.95752,1973.598,5479.52930,880.840,
4401.04883,1973.598,5479.62109,880.840,
4401.14063,1973.598,5479.71240,880.840,
4401.23193,1973.598,5479.80420,879.840,
4401.32373,1972.598,5479.89551,880.840,
4401.41504,1972.598,5479.98682,879.840,
4401.50684,1972.598,5480.07861,879.840,
4401.59814,1971.598,5480.16992,879.840,
4401.68994,1971.598,5480.26172,880.840,
4401.78125,1971.598,5480.35303,880.840,
4401.87256,1970.598,5480.44482,881.840,
4401.96436,1970.598,5480.53613,880.840,
4402.05566,1970.598,5480.62744,880.840,
4402.14746,1970.598,5480.71924,880.840,
4402.23877,1969.598,5480.81055,879.840,
4402.33057,1969.598,5480.90234,879.840,
4402.42188,1969.598,5480.99365,878.840,
4402.51318,1968.598,5481.08545,878.840,
4402.60498,1969.598,5481.17676,877.840,
4402.69629,1968.598,5481.26807,877.840,
4402.78809,1968.598,5481.35986,877.840,
4402.87939,1967.598,5481.45117,876.840,
4402.97119,1967.598,5481.54297,876.840,
4403.06250,1966.598,5481.63428,876.840,
4403.15381,1967.598,5481.72607,876.840,
4403.24561,1966.598,5481.81738,875.840,
4403.33691,1966.598,5481.90869,875.840,
4403.42871,1966.598,5482.00049,874.840,
4403.52002,1966.598,5482.09180,874.840,
4403.61182,1965.598,5482.18359,875.840,
4403.70313,1965.598,5482.27490,875.840,
4403.79492,1965.598,5482.36670,875.840,
4403.88623,1964.598,5482.45801,875.840,
4403.97754,1964.598,5482.54980,876.840,
4404.06934,1964.598,5482.64111,875.840,
4404.16064,1964.598,5482.73242,875.840,
4404.25244,1963.598,5482.82422,875.840,
4404.34375,1963.598,5482.91553,874.840,
4404.43555,1962.598,5483.00732,874.840,
4404.52686,1962.598,5483.09863,873.840,
4404.61816,1962.598,5483.19043,873.840,
4404.70996,1962.598,5483.28174,873.840,
4404.80127,1961.598,5483.37305,873.840,
4404.89307,1961.598,5483.46484,872.840,
4404.98438,1961.598,5483.55615,872.840,
4405.07617,1961.598,5483.64795,871.840,
4405.16748,1960.598,5483.73926,871.840,
4405.25879,1960.598,5483.83105,870.840,
4405.35059,1960.598,5483.92236,870.840,
4405.44189,1960.598,5484.01367,869.840,
4405.53369,1959.598,5484.10547,869.840,
4405.62500,1959.598,5484.19678,868.840,
4405.71680,1958.598,5484.28857,868.840,
4405.80811,1958.598,5484.37988,868.840,
4405.89990,1958.598,5484.47168,867.840,
4405.99121,1957.598,5484.56299,867.840,
4406.08252,1957.598,5484.65479,867.840,
4406.17432,1957.598,5484.74609,866.840,
4406.26563,1957.598,5484.83740,867.840,
4406.35742,1956.598,5484.92920,866.840,
4406.44873,1956.598,5485.02051,866.840,
4406.54053,1956.598,5485.11230,866.840,
4406.63184,1956.598,5485.20361,866.840,
4406.72314,1955.598,5485.29541,865.840,
4406.81494,1955.598,5485.38672,865.840,
4406.90625,1955.598,5485.47803,865.840,
4406.99805,1955.598,5485.56982,865.840,
4407.08936,1955.598,5485.66113,864.840,
4407.18115,1954.598,5485.75293,864.840,
4407.27246,1954.598,5485.84424,864.840,
4407.36377,1954.598,5485.93604,864.840,
4407.45557,1954.598,5486.02734,863.840,
4407.54688,1953.598,5486.11865,863.840,
4407.63867,1953.598,5486.21045,863.840,
4407.72998,1953.598,5486.30176,863.840,
4407.82178,1952.598,5486.39355,862.840,
4407.91309,1952.598,5486.48486,863.840,
4408.00488,1951.598,5486.57666,862.840,
4408.09619,1951.598,5486.66797,862.840,
4408.18750,1951.598,5486.75977,862.840,
4408.27930,1951.598,5486.85107,861.840,
4408.37061,1951.598,5486.94238,861.840,
4408.46240,1950.598,5487.03418,861.840,
4408.55371,1950.598,5487.12549,860.840,
4408.64551,1950.598,5487.21729,860.840,
4408.73682,1950.598,5487.30859,860.840,
4408.82813,1949.598,5487.40039,860.840,
4408.91992,1949.598,5487.49170,859.840,
4409.01123,1949.598,5487.58301,860.840,
4409.10303,1949.598,5487.67480,859.840,
4409.19434,1948.598,5487.76611,860.840,
4409.28613,1948.598,5487.85791,859.840,
4409.37744,1947.598,5487.94922,859.840,
4409.46875,1947.598,5488.04102,858.840,
4409.56055,1947.598,5488.13232,858.840,
4409.65186,1947.598,5488.22363,858.840,
4409.74365,1946.598,5488.31543,858.840,
4409.83496,1946.598,5488.40674,857.840,
4409.92676,1946.598,5488.49854,857.840,
4410.01807,1946.598,5488.58984,857.840,
4410.10938,1945.598,5488.68164,856.840,
4410.20117,1945.598,5488.77295,856.840,
4410.29248,1945.598,5488.86475,856.840,
4410.38428,1945.598,5488.95605,856.840,
4410.47559,1945.598,5489.04736,856.840,
4410.56738,1944.598,5489.13916,856.840,
4410.65869,1944.598,5489.23047,856.840,
4410.75049,1943.598,5489.32227,855.840,
4410.84180,1943.598,5489.41357,855.840,
4410.93311,1943.598,5489.50537,855.840,
4411.02490,1943.598,5489.59668,854.840,
4411.11621,1942.598,5489.68799,854.840,
4411.20801,1942.598,5489.77979,854.840,
4411.29932,1942.598,5489.87109,853.840,
4411.39111,1941.598,5489.96289,853.840,
4411.48242,1942.598,5490.05420,853.840,
4411.57373,1941.598,5490.14600,853.840,
4411.66553,1940.598,5490.23730,853.840,
4411.75684,1940.598,5490.32861,853.840,
4411.84863,1940.598,5490.42041,852.840,
4411.93994,1939.598,5490.51172,852.840,
4412.03174,1939.598,5490.60352,852.840,
4412.12305,1939.598,5490.69482,852.840,
4412.21436,1939.598,5490.78662,851.840,
4412.30615,1938.598,5490.87793,851.840,
4412.39746,1938.598,5490.96973,851.840,
4412.48926,1939.598,5491.06104,850.840,
4412.58057,1937.598,5491.15234,850.840,
4412.67236,1938.598,5491.24414,850.840,
4412.76367,1937.598,5491.33545,850.840,
4412.85547,1937.598,5491.42725,850.840,
4412.94678,1937.598,5491.51855,849.840,
4413.03809,1936.598,5491.61035,849.840,
4413.12988,1936.598,5491.70166,848.840,
4413.22119,1936.598,5491.79297,849.840,
4413.31299,1935.598,5491.88477,849.840,
4413.40430,1936.598,5491.97607,848.840,
4413.49609,1935.598,5492.06787,848.840,
4413.58740,1935.598,5492.15918,848.840,
4413.67871,1934.598,5492.25098,847.840,
4413.77051,1934.598,5492.34229,847.840,
4413.86182,1933.598,5492.43359,847.840,
4413.95361,1933.598,5492.52539,848.840,
4414.04492,1933.598,5492.61670,847.840,
4414.13672,1933.598,5492.70850,846.840,
4414.22803,1933.598,5492.79980,846.840,
4414.31934,1932.598,5492.89160,846.840,
4414.41113,1933.598,5492.98291,846.840,
4414.50244,1932.598,5493.07422,845.840,
4414.59424,1932.598,5493.16602,845.840,
4414.68555,1931.598,5493.25732,845.840,
4414.77734,1931.598,5493.34912,845.840,
4414.86865,1930.598,5493.44043,844.840,
4414.96045,1930.598,5493.53223,844.840,
4415.05176,1929.598,5493.62354,844.840,
4415.14307,1928.598,5493.71533,843.840,
4415.23486,1928.598,5493.80664,844.840,
4415.32617,1927.598,5493.89795,843.840,
4415.41797,1926.598,5493.98975,843.840,
4415.50928,1926.598,5494.08105,843.840,
4415.60107,1926.598,5494.17285,842.840,
4415.69238,1926.598,5494.26416,843.840,
4415.78369,1925.598,5494.35596,842.840,
4415.87549,1926.598,5494.44727,842.840,
4415.96680,1925.598,5494.53857,841.840,
4416.05859,1925.598,5494.63037,842.840,
4416.14990,1925.598,5494.72168,841.840,
4416.24170,1925.598,5494.81348,841.840,
4416.33301,1925.598,5494.90479,841.840,
4416.42432,1925.598,5494.99658,841.840,
4416.51611,1925.598,5495.08789,840.840,
4416.60742,1924.598,5495.17920,840.840,
4416.69922,1924.598,5495.27100,840.840,
4416.79053,1924.598,5495.36230,840.840,
4416.88232,1924.598,5495.45410,839.840,
4416.97363,1924.598,5495.54541,839.840,
4417.06543,1924.598,5495.63721,839.840,
4417.15674,1923.598,5495.72852,838.840,
4417.24805,1922.598,5495.82031,838.840,
4417.33984,1922.598,5495.91162,838.840,
4417.43115,1920.598,5496.00293,838.840,
4417.52295,1919.598,5496.09473,838.840,
4417.61426,1919.598,5496.18604,837.840,
4417.70605,1918.598,5496.27783,837.840,
4417.79736,1918.598,5496.36914,837.840,
4417.88867,1918.598,5496.46094,837.840,
4417.98047,1917.598,5496.55225,837.840,
4418.07178,1917.598,5496.64355,837.840,
4418.16357,1917.598,5496.73535,836.840,
4418.25488,1918.598,5496.82666,836.840,
4418.34668,1917.598,5496.91846,836.840,
4418.43799,1917.598,5497.00977,836.840,
4418.52930,1917.598,5497.10156,835.840,
4418.62109,1917.598,5497.19287,835.840,
4418.71240,1917.598,5497.28418,835.840,
4418.80420,1918.598,5497.37598,834.840,
4418.89551,1917.598,5497.46729,835.840,
4418.98730,1917.598,5497.55908,834.840,
4419.07861,1917.598,5497.65039,834.840,
4419.17041,1917.598,5497.74219,834.840,
4419.26172,1916.598,5497.83350,833.840,
4419.35303,1916.598,5497.92529,834.840,
4419.44482,1916.598,5498.01660,834.840,
4419.53613,1916.598,5498.10791,833.840,
4419.62793,1916.598,5498.19971,833.840,
4419.71924,1916.598,5498.29102,832.840,
4419.81104,1915.598,5498.38281,832.840,
4419.90234,1915.598,5498.47412,833.840,
4419.99365,1915.598,5498.56592,832.840,
4420.08545,1914.598,5498.65723,831.840,
4420.17676,1914.598,5498.74854,831.840,
4420.26855,1915.598,5498.84033,831.840,
4420.35986,1914.598,5498.93164,831.840,
4420.45166,1913.598,5499.02344,830.840,
4420.54297,1914.598,5499.11475,830.840,
4420.63428,1913.598,5499.20654,830.840,
4420.72607,1912.598,5499.29785,830.840,
4420.81738,1912.598,5499.38916,829.840,
4420.90918,1912.598,5499.48096,830.840,
4421.00049,1912.598,5499.57227,829.840,
4421.09229,1911.598,5499.66406,829.840,
4421.18359,1911.598,5499.75537,829.840,
4421.27490,1911.598,5499.84717,829.840,
4421.36670,1911.598,5499.93848,828.840,
4421.45801,1910.598,5500.03027,829.840,
4421.54980,1910.598,5500.12158,828.840,
4421.64111,1909.598,5500.21289,828.840,
4421.73291,1910.598,5500.30469,827.840,
4421.82422,1910.598,5500.39600,827.840,
4421.91602,1909.598,5500.48779,827.840,
4422.00732,1909.598,5500.57910,827.840,
4422.09863,1909.598,5500.67090,827.840,
4422.19043,1908.598,5500.76221,827.840,
4422.28174,1908.598,5500.85352,827.840,
4422.37354,1908.598,5500.94531,827.840,
4422.46484,1908.598,5501.03662,826.840,
4422.55664,1907.598,5501.12842,826.840,
4422.64795,1907.598,5501.21973,826.840,
4422.73926,1907.598,5501.31152,825.840,
4422.83105,1907.598,5501.40283,825.840,
4422.92236,1906.598,5501.49414,825.840,
4423.01416,1906.598,5501.58594,825.840,
4423.10547,1906.598,5501.67725,823.840,
4423.19727,1906.598,5501.76904,822.840,
4423.28857,1905.598,5501.86035,822.840,
4423.37988,1905.598,5501.95215,822.840,
4423.47168,1904.598,5502.04346,821.840,
4423.56299,1905.598,5502.13525,821.840,
4423.65479,1904.598,5502.22656,821.840,
4423.74609,1903.598,5502.31787,821.840,
4423.83789,1903.598,5502.40967,821.840,
4423.92920,1903.598,5502.50098,821.840,
4424.02100,1902.598,5502.59277,821.840,
4424.11230,1903.598,5502.68408,820.840,
4424.20361,1902.598,5502.77588,820.840,
4424.29541,1902.598,5502.86719,820.840,
4424.38672,1901.598,5502.95850,821.840,
4424.47852,1901.598,5503.05029,820.840,
4424.56982,1901.598,5503.14160,820.840,
4424.66162,1901.598,5503.23340,820.840,
4424.75293,1901.598,5503.32471,820.840,
4424.84424,1901.598,5503.41650,820.840,
4424.93604,1900.598,5503.50781,820.840,
4425.02734,1900.598,5503.59912,819.840,
4425.11914,1899.598,5503.69092,819.840,
4425.21045,1899.598,5503.78223,819.840,
4425.30225,1899.598,5503.87402,820.840,
4425.39355,1898.598,5503.96533,819.840,
4425.48486,1898.598,5504.05713,820.840,
4425.57666,1898.598,5504.14844,820.840,
4425.66797,1898.598,5504.24023,821.840,
4425.75977,1898.598,5504.33154,820.840,
4425.85107,1897.598,5504.42285,820.840,
4425.94287,1897.598,5504.51465,820.840,
4426.03418,1897.598,5504.60596,820.840,
4426.12598,1897.598,5504.69775,819.840,
4426.21729,1896.598,5504.78906,819.840,
4426.30859,1895.598,5504.88086,818.840,
4426.40039,1895.598,5504.97217,818.840,
4426.49170,1895.598,5505.06348,818.840,
4426.58350,1895.598,5505.15527,818.840,
4426.67480,1895.598,5505.24658,816.840,
4426.76660,1894.598,5505.33838,817.840,
4426.85791,1894.598,5505.42969,816.840,
4426.94922,1893.598,5505.52148,816.840,
4427.04102,1893.598,5505.61279,815.840,
4427.13232,1893.598,5505.70410,815.840,
4427.22412,1893.598,5505.79590,815.840,
4427.31543,1892.598,5505.88721,814.840,
4427.40723,1892.598,5505.97900,814.840,
4427.49854,1892.598,5506.07031,814.840,
4427.58984,1892.598,5506.16211,814.840,
4427.68164,1891.598,5506.25342,813.840,
4427.77295,1891.598,5506.34473,813.840,
4427.86475,1891.598,5506.43652,813.840,
4427.95605,1891.598,5506.52783,813.840,
4428.04785,1890.598,5506.61963,812.840,
4428.13916,1891.598,5506.71094,812.840,
4428.23096,1890.598,5506.80273,813.840,
4428.32227,1890.598,5506.89404,812.840,
4428.41357,1889.598,5506.98584,812.840,
4428.50537,1889.598,5507.07715,812.840,
4428.59668,1889.598,5507.16846,811.840,
4428.68848,1889.598,5507.26025,811.840,
4428.77979,1889.598,5507.35156,811.840,
4428.87158,1888.598,5507.44336,811.840,
4428.96289,1887.598,5507.53467,810.840,
4429.05420,1888.598,5507.62646,810.840,
4429.14600,1887.598,5507.71777,810.840,
4429.23730,1887.598,5507.80908,810.840,
4429.32910,1886.598,5507.90088,809.840,
4429.42041,1886.598,5507.99219,810.840,
4429.51221,1886.598,5508.08398,809.840,
4429.60352,1886.598,5508.17529,809.840,
4429.69482,1885.598,5508.26709,809.840,
4429.78662,1885.598,5508.35840,809.840,
4429.87793,1884.598,5508.44971,809.840,
4429.96973,1885.598,5508.54150,808.840,
4430.06104,1884.598,5508.63281,808.840,
4430.15283,1884.598,5508.72461,808.840,
4430.24414,1884.598,5508.81592,808.840,
4430.33594,1883.598,5508.90771,807.840,
4430.42725,1883.598,5508.99902,807.840,
4430.51855,1884.598,5509.09082,807.840,
4430.61035,1882.598,5509.18213,807.840,
4430.70166,1882.598,5509.27344,806.840,
4430.79346,1882.598,5509.36523,806.840,
4430.88477,1882.598,5509.45654,805.840,
4430.97656,1881.598,5509.54834,805.840,
4431.06787,1881.598,5509.63965,805.840,
4431.15918,1881.598,5509.73145,805.840,
4431.25098,1881.598,5509.82275,805.840,
4431.34229,1880.598,5509.91406,805.840,
4431.43408,1880.598,5510.00586,804.840,
4431.52539,1880.598,5510.09717,804.840,
4431.61719,1880.598,5510.18896,804.840,
4431.70850,1879.598,5510.28027,804.840,
4431.79980,1879.598,5510.37207,804.840,
4431.89160,1878.598,5510.46338,803.840,
4431.98291,1879.598,5510.55469,803.840,
4432.07471,1878.598,5510.64648,803.840,
4432.16602,1878.598,5510.73779,803.840,
4432.25781,1878.598,5510.82959,802.840,
4432.34912,1878.598,5510.92090,802.840,
4432.44092,1877.598,5511.01270,802.840,
4432.53223,1877.598,5511.10400,801.840,
4432.62354,1877.598,5511.19580,802.840,
4432.71533,1877.598,5511.28711,802.840,
4432.80664,1875.598,5511.37842,802.840,
4432.89844,1875.598,5511.47021,801.840,
4432.98975,1875.598,5511.56152,801.840,
4433.08154,1875.598,5511.65332,801.840,
4433.17285,1875.598,5511.74463,801.840,
4433.26416,1875.598,5511.83643,800.840,
4433.35596,1874.598,5511.92773,800.840,
4433.44727,1874.598,5512.01904,800.840,
4433.53906,1874.598,5512.11084,799.840,
4433.63037,1873.598,5512.20215,800.840,
4433.72217,1874.598,5512.29395,798.840,
4433.81348,1873.598,5512.38525,799.840,
4433.90479,1873.598,5512.47705,799.840,
4433.99658,1872.598,5512.56836,799.840,
4434.08789,1872.598,5512.65967,799.840,
4434.17969,1871.598,5512.75146,799.840,
4434.27100,1871.598,5512.84277,798.840,
4434.36279,1870.598,5512.93457,798.840,
4434.45410,1870.598,5513.02588,798.840,
4434.54541,1870.598,5513.11768,798.840,
4434.63721,1870.598,5513.20898,797.840,
4434.72852,1870.598,5513.30078,797.840,
4434.82031,1870.598,5513.39209,797.840,
4434.91162,1870.598,5513.48340,797.840,
4435.00342,1869.598,5513.57520,796.840,
4435.09473,1869.598,5513.66650,796.840,
4435.18652,1868.598,5513.75830,796.840,
4435.27783,1869.598,5513.84961,795.840,
4435.36914,1870.598,5513.94141,795.840,
4435.46094,1870.598,5514.03271,795.840,
4435.55225,1870.598,5514.12402,796.840,
4435.64404,1870.598,5514.21582,795.840,
4435.73535,1870.598,5514.30713,795.840,
4435.82715,1870.598,5514.39893,794.840,
4435.91846,1870.598,5514.49023,794.840,
4436.00977,1870.598,5514.58203,794.840,
4436.10156,1869.598,5514.67334,794.840,
4436.19287,1869.598,5514.76465,794.840,
4436.28467,1868.598,5514.85645,794.840,
4436.37598,1868.598,5514.94775,793.840,
4436.46777,1867.598,5515.03955,793.840,
4436.55908,1867.598,5515.13086,793.840,
4436.65039,1866.598,5515.22266,793.840,
4436.74219,1866.598,5515.31396,792.840,
4436.83350,1865.598,5515.40576,792.840,
4436.92529,1865.598,5515.49707,792.840,
4437.01660,1864.598,5515.58838,792.840,
4437.10840,1864.598,5515.68018,792.840,
4437.19971,1864.598,5515.77148,791.840,
4437.29150,1863.598,5515.86328,791.840,
4437.38281,1863.598,5515.95459,791.840,
4437.47412,1862.598,5516.04639,790.840,
4437.56592,1862.598,5516.13770,790.840,
4437.65723,1861.598,5516.22900,790.840,
4437.74902,1861.598,5516.32080,790.840,
4437.84033,1860.598,5516.41211,789.840,
4437.93213,1859.598,5516.50391,789.840,
4438.02344,1859.598,5516.59521,789.840,
4438.11475,1858.598,5516.68701,789.840,
4438.20654,1858.598,5516.77832,789.840,
4438.29785,1858.598,5516.86963,788.840,
4438.38965,1857.598,5516.96143,788.840,
4438.48096,1857.598,5517.05273,789.840,
4438.57275,1857.598,5517.14453,788.840,
4438.66406,1857.598,5517.23584,787.840,
4438.75537,1857.598,5517.32764,788.840,
4438.84717,1857.598,5517.41895,787.840,
4438.93848,1857.598,5517.51074,787.840,
4439.03027,1856.598,5517.60205,787.840,
4439.12158,1856.598,5517.69336,787.840,
4439.21338,1856.598,5517.78516,787.840,
4439.30469,1857.598,5517.87646,786.840,
4439.39648,1855.598,5517.96826,786.840,
4439.48779,1855.598,5518.05957,786.840,
4439.57910,1855.598,5518.15137,785.840,
4439.67090,1855.598,5518.24268,785.840,
4439.76221,1855.598,5518.33398,786.840,
4439.85400,1855.598,5518.42578,786.840,
4439.94531,1855.598,5518.51709,785.840,
4440.03711,1854.598,5518.60889,785.840,
4440.12842,1854.598,5518.70020,785.840,
4440.21973,1853.598,5518.79199,784.840,
4440.31152,1853.598,5518.88330,784.840,
4440.40283,1853.598,5518.97461,784.840,
4440.49463,1853.598,5519.06641,783.840,
4440.58594,1852.598,5519.15771,784.840,
4440.67773,1852.598,5519.24951,783.840,
4440.76904,1852.598,5519.34082,783.840,
4440.86035,1851.598,5519.43262,782.840,
4440.95215,1851.598,5519.52393,782.840,
4441.04346,1851.598,5519.61523,782.840,
4441.13525,1851.598,5519.70703,781.840,
4441.22656,1850.598,5519.79834,781.840,
4441.31836,1850.598,5519.89014,781.840,
4441.40967,1849.598,5519.98145,782.840,
4441.50146,1850.598,5520.07324,781.840,
4441.59277,1849.598,5520.16455,781.840,
4441.68408,1848.598,5520.25635,781.840,
4441.77588,1848.598,5520.34766,780.840,
4441.86719,1848.598,5520.43896,781.840,
4441.95898,1849.598,5520.53076,780.840,
4442.05029,1848.598,5520.62207,780.840,
4442.14209,1847.598,5520.71387,780.840,
4442.23340,1848.598,5520.80518,779.840,
4442.32471,1847.598,5520.89697,779.840,
4442.41650,1847.598,5520.98828,779.840,
4442.50781,1847.598,5521.07959,778.840,
4442.59961,1846.598,5521.17139,778.840,
4442.69092,1846.598,5521.26270,778.840,
4442.78271,1846.598,5521.35449,778.840,
4442.87402,1845.598,5521.44580,779.840,
4442.96533,1845.598,5521.53760,778.840,
4443.05713,1845.598,5521.62891,778.840,
4443.14844,1845.598,5521.72021,778.840,
4443.24023,1844.598,5521.81201,777.840,
4443.33154,1844.598,5521.90332,777.840,
4443.42334,1845.598,5521.99512,777.840,
4443.51465,1844.598,5522.08643,777.840,
4443.60645,1843.598,5522.17822,777.840,
4443.69775,1844.598,5522.26953,776.840,
4443.78906,1843.598,5522.36133,776.840,
4443.88086,1842.598,5522.45264,776.840,
4443.97217,1842.598,5522.54395,776.840,
4444.06396,1842.598,5522.63574,775.840,
4444.15527,1841.598,5522.72705,775.840,
4444.24707,1841.598,5522.81885,775.840,
4444.33838,1841.598,5522.91016,775.840,
4444.42969,1840.598,5523.00195,775.840,
4444.52148,1840.598,5523.09326,775.840,
4444.61279,1840.598,5523.18457,774.840,
4444.70459,1839.598,5523.27637,774.840,
4444.79590,1839.598,5523.36768,773.840,
4444.88770,1839.598,5523.45947,773.840,
4444.97900,1839.598,5523.55078,773.840,
4445.07031,1839.598,5523.64258,772.840,
4445.16211,1839.598,5523.73389,772.840,
4445.25342,1838.598,5523.82520,771.840,
4445.34521,1838.598,5523.91699,771.840,
4445.43652,1838.598,5524.00830,771.840,
4445.52832,1837.598,5524.10010,770.840,
4445.61963,1837.598,5524.19141,770.840,
4445.71094,1837.598,5524.28320,769.840,
4445.80273,1837.598,5524.37451,769.840,
4445.89404,1837.598,5524.46631,769.840,
4445.98584,1836.598,5524.55762,768.840,
4446.07715,1836.598,5524.64893,768.840,
4446.16895,1836.598,5524.74072,768.840,
4446.26025,1835.598,5524.83203,768.840,
4446.35205,1836.598,5524.92383,768.840,
4446.44336,1835.598,5525.01514,768.840,
4446.53467,1835.598,5525.10693,768.840,
4446.62646,1835.598,5525.19824,767.840,
4446.71777,1834.598,5525.28955,767.840,
4446.80957,1834.598,5525.38135,768.840,
4446.90088,1833.598,5525.47266,767.840,
4446.99268,1833.598,5525.56445,767.840,
4447.08398,1833.598,5525.65576,767.840,
4447.17529,1832.598,5525.74756,767.840,
4447.26709,1832.598,5525.83887,768.840,
4447.35840,1832.598,5525.93018,768.840,
4447.45020,1831.598,5526.02197,768.840,
4447.54150,1831.598,5526.11328,768.840,
4447.63330,1831.598,5526.20508,768.840,
4447.72461,1831.598,5526.29639,768.840,
4447.81592,1830.598,5526.38818,768.840,
4447.90771,1831.598,5526.47949,768.840,
4447.99902,1830.598,5526.57129,768.840,
4448.09082,1830.598,5526.66260,768.840,
4448.18213,1829.598,5526.75391,767.840,
4448.27393,1829.598,5526.84570,767.840,
4448.36523,1829.598,5526.93701,767.840,
4448.45703,1828.598,5527.02881,766.840,
4448.54834,1829.598,5527.12012,766.840,
4448.63965,1828.598,5527.21191,765.840,
4448.73145,1828.598,5527.30322,766.840,
4448.82275,1828.598,5527.39453,765.840,
4448.91455,1827.598,5527.48633,765.840,
4449.00586,1827.598,5527.57764,764.840,
4449.09766,1827.598,5527.66943,764.840,
4449.18896,1827.598,5527.76074,764.840,
4449.28027,1826.598,5527.85254,763.840,
4449.37207,1825.598,5527.94385,763.840,
4449.46338,1826.598,5528.03516,763.840,
4449.55518,1826.598,5528.12695,763.840,
4449.64648,1825.598,5528.21826,762.840,
4449.73828,1825.598,5528.31006,762.840,
4449.82959,1824.598,5528.40137,762.840,
4449.92090,1825.598,5528.49316,761.840,
4450.01270,1824.598,5528.58447,761.840,
4450.10400,1823.598,5528.67627,761.840,
4450.19580,1823.598,5528.76758,761.840,
4450.28711,1823.598,5528.85889,760.840,
4450.37891,1823.598,5528.95068,761.840,
4450.47021,1822.598,5529.04199,760.840,
4450.56201,1822.598,5529.13379,760.840,
4450.65332,1822.598,5529.22510,760.840,
4450.74463,1821.598,5529.31689,760.840,
4450.83643,1821.598,5529.40820,760.840,
4450.92773,1821.598,5529.49951,759.840,
4451.01953,1821.598,5529.59131,759.840,
4451.11084,1821.598,5529.68262,759.840,
4451.20264,1820.598,5529.77441,758.840,
4451.29395,1819.598,5529.86572,758.840,
4451.38525,1819.598,5529.95752,758.840,
4451.47705,1819.598,5530.04883,758.840,
4451.56836,1819.598,5530.14014,758.840,
4451.66016,1818.598,5530.23193,758.840,
4451.75146,1818.598,5530.32324,757.840,
4451.84326,1818.598,5530.41504,757.840,
4451.93457,1817.598,5530.50635,757.840,
4452.02588,1818.598,5530.59814,757.840,
4452.11768,1817.598,5530.68945,757.840,
4452.20898,1817.598,5530.78076,756.840,
4452.30078,1817.598,5530.87256,757.840,
4452.39209,1817.598,5530.96387,756.840,
4452.48389,1817.598,5531.05566,756.840,
4452.57520,1816.598,5531.14697,755.840,
4452.66699,1816.598,5531.23877,755.840,
4452.75830,1816.598,5531.33008,755.840,
4452.84961,1815.598,5531.42188,755.840,
4452.94141,1815.598,5531.51318,755.840,
4453.03271,1815.598,5531.60449,755.840,
4453.12451,1814.598,5531.69629,755.840,
4453.21582,1814.598,5531.78760,754.840,
4453.30762,1814.598,5531.87939,754.840,
4453.39893,1814.598,5531.97070,754.840,
4453.49023,1813.598,5532.06250,754.840,
4453.58203,1812.598,5532.15381,753.840,
4453.67334,1813.598,5532.24512,753.840,
4453.76514,1812.598,5532.33691,753.840,
4453.85645,1812.598,5532.42822,753.840,
4453.94824,1812.598,5532.52002,753.840,
4454.03955,1811.598,5532.61133,752.840,
4454.13086,1811.598,5532.70313,752.840,
4454.22266,1811.598,5532.79443,752.840,
4454.31396,1810.598,5532.88574,751.840,
4454.40576,1811.598,5532.97754,752.840,
4454.49707,1810.598,5533.06885,751.840,
4454.58887,1810.598,5533.16064,752.840,
4454.68018,1810.598,5533.25195,751.840,
4454.77197,1810.598,5533.34375,751.840,
4454.86328,1810.598,5533.43506,750.840,
4454.95459,1809.598,5533.52686,751.840,
4455.04639,1809.598,5533.61816,750.840,
4455.13770,1809.598,5533.70947,750.840,
4455.22949,1808.598,5533.80127,750.840,
4455.32080,1808.598,5533.89258,749.840,
4455.41260,1808.598,5533.98438,749.840,
4455.50391,1807.598,5534.07568,749.840,
4455.59521,1807.598,5534.16748,749.840,
4455.68701,1807.598,5534.25879,748.840,
4455.77832,1807.598,5534.35010,748.840,
4455.87012,1807.598,5534.44189,748.840,
4455.96143,1806.598,5534.53320,748.840,
4456.05322,1806.598,5534.62500,748.840,
4456.14453,1806.598,5534.71631,748.840,
4456.23584,1806.598,5534.80811,747.840,
4456.32764,1806.598,5534.89941,747.840,
4456.41895,1806.598,5534.99072,747.840,
4456.51074,1805.598,5535.08252,747.840,
4456.60205,1805.598,5535.17383,747.840,
4456.69385,1805.598,5535.26563,747.840,
4456.78516,1805.598,5535.35693,746.840,
4456.87695,1805.598,5535.44873,746.840,
4456.96826,1804.598,5535.54004,745.840,
4457.05957,1804.598,5535.63184,745.840,
4457.15137,1804.598,5535.72314,745.840,
4457.24268,1804.598,5535.81445,745.840,
4457.33447,1803.598,5535.90625,745.840,
4457.42578,1803.598,5535.99756,745.840,
4457.51758,1802.598,5536.08936,745.840,
4457.60889,1802.598,5536.18066,744.840,
4457.70020,1801.598,5536.27246,744.840,
4457.79199,1801.598,5536.36377,744.840,
4457.88330,1801.598,5536.45508,743.840,
4457.97510,1801.598,5536.54688,744.840,
4458.06641,1801.598,5536.63818,743.840,
4458.15820,1800.598,5536.72998,743.840,
4458.24951,1800.598,5536.82129,743.840,
4458.34082,1799.598,5536.91309,743.840,
4458.43262,1797.598,5537.00439,742.840,
4458.52393,1796.598,5537.09570,742.840,
4458.61572,1795.598,5537.18750,741.840,
4458.70703,1794.598,5537.27881,741.840,
4458.79883,1793.598,5537.37061,741.840,
4458.89014,1793.598,5537.46191,741.840,
4458.98145,1793.598,5537.55371,741.840,
4459.07324,1794.598,5537.64502,741.840,
4459.16455,1793.598,5537.73682,740.840,
4459.25635,1793.598,5537.82813,740.840,
4459.34766,1793.598,5537.91943,740.840,
4459.43945,1793.598,5538.01123,740.840,
4459.53076,1793.598,5538.10254,740.840,
4459.62256,1793.598,5538.19434,740.840,
4459.71387,1793.598,5538.28564,739.840,
4459.80518,1794.598,5538.37744,739.840,
4459.89697,1793.598,5538.46875,739.840,
4459.98828,1793.598,5538.56006,738.840,
4460.08008,1793.598,5538.65186,738.840,
4460.17139,1793.598,5538.74316,739.840,
4460.26318,1793.598,5538.83496,738.840,
4460.35449,1793.598,5538.92627,738.840,
4460.44580,1792.598,5539.01807,738.840,
4460.53760,1792.598,5539.10938,737.840,
4460.62891,1791.598,5539.20068,737.840,
4460.72070,1792.598,5539.29248,737.840,
4460.81201,1791.598,5539.38379,737.840,
4460.90381,1791.598,5539.47559,736.840,
4460.99512,1791.598,5539.56689,737.840,
4461.08643,1791.598,5539.65869,736.840,
4461.17822,1791.598,5539.75000,736.840,
4461.26953,1791.598,5539.84180,736.840,
4461.36133,1789.598,5539.93311,736.840,
4461.45264,1789.598,5540.02441,735.840,
4461.54443,1789.598,5540.11621,735.840,
4461.63574,1789.598,5540.20752,735.840,
4461.72754,1788.598,5540.29932,735.840,
4461.81885,1788.598,5540.39063,735.840,
4461.91016,1788.598,5540.48242,735.840,
4462.00195,1788.598,5540.57373,735.840,
4462.09326,1788.598,5540.66504,734.840,
4462.18506,1787.598,5540.75684,734.840,
4462.27637,1787.598,5540.84814,734.840,
4462.36816,1787.598,5540.93994,734.840,
4462.45947,1787.598,5541.03125,734.840,
4462.55078,1786.598,5541.12305,733.840,
4462.64258,1786.598,5541.21436,733.840,
4462.73389,1786.598,5541.30566,732.840,
4462.82568,1785.598,5541.39746,732.840,
4462.91699,1785.598,5541.48877,732.840,
4463.00879,1785.598,5541.58057,732.840,
4463.10010,1785.598,5541.67188,731.840,
4463.19141,1784.598,5541.76367,731.840,
4463.28320,1784.598,5541.85498,731.840,
4463.37451,1783.598,5541.94678,731.840,
4463.46631,1783.598,5542.03809,731.840,
4463.55762,1783.598,5542.12939,731.840,
4463.64941,1783.598,5542.22119,731.840,
4463.74072,1782.598,5542.31250,731.840,
4463.83252,1783.598,5542.40430,730.840,
4463.92383,1782.598,5542.49561,730.840,
4464.01514,1781.598,5542.58740,730.840,
4464.10693,1781.598,5542.67871,730.840,
4464.19824,1782.598,5542.77002,729.840,
4464.29004,1781.598,5542.86182,729.840,
4464.38135,1781.598,5542.95313,729.840,
4464.47314,1780.598,5543.04492,729.840,
4464.56445,1780.598,5543.13623,728.840,
4464.65576,1779.598,5543.22803,728.840,
4464.74756,1779.598,5543.31934,728.840,
4464.83887,1779.598,5543.41064,729.840,
4464.93066,1779.598,5543.50244,728.840,
4465.02197,1779.598,5543.59375,728.840,
4465.11377,1778.598,5543.68555,728.840,
4465.20508,1778.598,5543.77686,727.840,
4465.29639,1778.598,5543.86865,727.840,
4465.38818,1778.598,5543.95996,727.840,
4465.47949,1777.598,5544.05127,726.840,
4465.57129,1777.598,5544.14307,727.840,
4465.66260,1778.598,5544.23438,726.840,
4465.75439,1776.598,5544.32617,726.840,
4465.84570,1776.598,5544.41748,725.840,
4465.93750,1776.598,5544.50928,726.840,
4466.02881,1776.598,5544.60059,725.840,
4466.12012,1776.598,5544.69238,725.840,
4466.21191,1775.598,5544.78369,725.840,
4466.30322,1775.598,5544.87500,725.840,
4466.39502,1775.598,5544.96680,724.840,
4466.48633,1774.598,5545.05811,724.840,
4466.57813,1774.598,5545.14990,724.840,
4466.66943,1774.598,5545.24121,724.840,
4466.76074,1773.598,5545.33301,723.840,
4466.85254,1773.598,5545.42432,724.840,
4466.94385,1773.598,5545.51563,723.840,
4467.03564,1772.598,5545.60742,722.840,
4467.12695,1773.598,5545.69873,723.840,
4467.21875,1772.598,5545.79053,722.840,
4467.31006,1772.598,5545.88184,722.840,
4467.40137,1772.598,5545.97363,722.840,
4467.49316,1771.598,5546.06494,722.840,
4467.58447,1770.598,5546.15625,721.840,
4467.67627,1771.598,5546.24805,721.840,
4467.76758,1770.598,5546.33936,721.840,
4467.85938,1770.598,5546.43115,720.840,
4467.95068,1770.598,5546.52246,719.840,
4468.04248,1769.598,5546.61426,719.840,
4468.13379,1770.598,5546.70557,718.840,
4468.22510,1769.598,5546.79736,718.840,
4468.31689,1769.598,5546.88867,717.840,
4468.40820,1769.598,5546.97998,717.840,
4468.50000,1768.598,5547.07178,718.840,
4468.59131,1768.598,5547.16309,717.840,
4468.68311,1767.598,5547.25488,717.840,
4468.77441,1767.598,5547.34619,717.840,
4468.86572,1767.598,5547.43799,717.840,
4468.95752,1767.598,5547.52930,717.840,
4469.04883,1766.598,5547.62061,717.840,
4469.14063,1766.598,5547.71240,717.840,
4469.23193,1766.598,5547.80371,717.840,
4469.32373,1766.598,5547.89551,717.840,
4469.41504,1765.598,5547.98682,717.840,
4469.50635,1765.598,5548.07861,717.840,
4469.59814,1765.598,5548.16992,717.840,
4469.68945,1765.598,5548.26123,717.840,
4469.78125,1764.598,5548.35303,717.840,
4469.87256,1764.598,5548.44434,716.840,
4469.96436,1764.598,5548.53613,717.840,
4470.05566,1764.598,5548.62744,716.840,
4470.14746,1763.598,5548.71924,717.840,
4470.23877,1763.598,5548.81055,717.840,
4470.33008,1763.598,5548.90234,717.840,
4470.42188,1763.598,5548.99365,718.840,
4470.51318,1763.598,5549.08496,718.840,
4470.60498,1762.598,5549.17676,718.840,
4470.69629,1762.598,5549.26807,719.840,
4470.78809,1762.598,5549.35986,718.840,
4470.87939,1761.598,5549.45117,717.840,
4470.97070,1761.598,5549.54297,717.840,
4471.06250,1761.598,5549.63428,717.840,
4471.15381,1761.598,5549.72559,716.840,
4471.24561,1760.598,5549.81738,715.840,
4471.33691,1760.598,5549.90869,715.840,
4471.42871,1760.598,5550.00049,715.840,
4471.52002,1759.598,5550.09180,714.840,
4471.61133,1759.598,5550.18359,713.840,
4471.70313,1759.598,5550.27490,713.840,
4471.79443,1759.598,5550.36621,713.840,
4471.88623,1758.598,5550.45801,712.840,
4471.97754,1758.598,5550.54932,712.840,
4472.06934,1757.598,5550.64111,712.840,
4472.16064,1757.598,5550.73242,712.840,
4472.25195,1757.598,5550.82422,712.840,
4472.34375,1757.598,5550.91553,711.840,
4472.43506,1756.598,5551.00732,711.840,
4472.52686,1756.598,5551.09863,711.840,
4472.61816,1756.598,5551.18994,711.840,
4472.70996,1755.598,5551.28174,711.840,
4472.80127,1755.598,5551.37305,710.840,
4472.89307,1755.598,5551.46484,710.840,
4472.98438,1755.598,5551.55615,709.840,
4473.07568,1754.598,5551.64795,709.840,
4473.16748,1754.598,5551.73926,709.840,
4473.25879,1754.598,5551.83057,709.840,
4473.35059,1753.598,5551.92236,709.840,
4473.44189,1753.598,5552.01367,709.840,
4473.53369,1753.598,5552.10547,708.840,
4473.62500,1753.598,5552.19678,709.840,
4473.71631,1752.598,5552.28857,708.840,
4473.80811,1752.598,5552.37988,708.840,
4473.89941,1752.598,5552.47119,708.840,
4473.99121,1752.598,5552.56299,707.840,
4474.08252,1752.598,5552.65430,708.840,
4474.17432,1751.598,5552.74609,707.840,
4474.26563,1751.598,5552.83740,707.840,
4474.35693,1751.598,5552.92920,707.840,
4474.44873,1751.598,5553.02051,706.840,
4474.54004,1750.598,5553.11230,706.840,
4474.63184,1750.598,5553.20361,706.840,
4474.72314,1750.598,5553.29492,706.840,
4474.81494,1749.598,5553.38672,706.840,
4474.90625,1749.598,5553.47803,705.840,
4474.99805,1749.598,5553.56982,706.840,
4475.08936,1748.598,5553.66113,706.840,
4475.18066,1748.598,5553.75293,705.840,
4475.27246,1748.598,5553.84424,705.840,
4475.36377,1748.598,5553.93555,705.840,
4475.45557,1747.598,5554.02734,704.840,
4475.54688,1747.598,5554.11865,704.840,
4475.63867,1747.598,5554.21045,704.840,
4475.72998,1747.598,5554.30176,704.840,
4475.82129,1746.598,5554.39355,703.840,
4475.91309,1747.598,5554.48486,704.840,
4476.00439,1746.598,5554.57617,703.840,
4476.09619,1746.598,5554.66797,703.840,
4476.18750,1745.598,5554.75928,703.840,
4476.27930,1745.598,5554.85107,703.840,
4476.37061,1744.598,5554.94238,702.840,
4476.46191,1745.598,5555.03418,702.840,
4476.55371,1744.598,5555.12549,703.840,
4476.64502,1744.598,5555.21729,702.840,
4476.73682,1743.598,5555.30859,701.840,
4476.82813,1743.598,5555.39990,701.840,
4476.91992,1743.598,5555.49170,701.840,
4477.01123,1742.598,5555.58301,700.840,
4477.10303,1742.598,5555.67480,700.840,
4477.19434,1740.598,5555.76611,700.840,
4477.28564,1740.598,5555.85791,700.840,
4477.37744,1741.598,5555.94922,700.840,
4477.46875,1739.598,5556.04053,700.840,
4477.56055,1739.598,5556.13232,700.840,
4477.65186,1739.598,5556.22363,699.840,
4477.74365,1739.598,5556.31543,699.840,
4477.83496,1738.598,5556.40674,699.840,
4477.92627,1738.598,5556.49854,699.840,
4478.01807,1738.598,5556.58984,699.840,
4478.10938,1738.598,5556.68115,699.840,
4478.20117,1738.598,5556.77295,698.840,
4478.29248,1738.598,5556.86426,698.840,
4478.38428,1737.598,5556.95605,698.840,
4478.47559,1737.598,5557.04736,697.840,
4478.56689,1737.598,5557.13916,697.840,
4478.65869,1737.598,5557.23047,697.840,
4478.75000,1737.598,5557.32178,697.840,
4478.84180,1737.598,5557.41357,697.840,
4478.93311,1736.598,5557.50488,697.840,
4479.02490,1737.598,5557.59668,696.840,
4479.11621,1736.598,5557.68799,696.840,
4479.20801,1737.598,5557.77979,696.840,
4479.29932,1736.598,5557.87109,696.840,
4479.39063,1736.598,5557.96289,696.840,
4479.48242,1736.598,5558.05420,696.840,
4479.57373,1735.598,5558.14551,695.840,
4479.66553,1735.598,5558.23730,695.840,
4479.75684,1734.598,5558.32861,695.840,
4479.84863,1734.598,5558.42041,695.840,
4479.93994,1733.598,5558.51172,695.840,
4480.03125,1733.598,5558.60352,694.840,
4480.12305,1733.598,5558.69482,694.840,
4480.21436,1733.598,5558.78613,694.840,
4480.30615,1733.598,5558.87793,694.840,
4480.39746,1733.598,5558.96924,694.840,
4480.48926,1732.598,5559.06104,693.840,
4480.58057,1732.598,5559.15234,693.840,
4480.67188,1732.598,5559.24414,693.840,
4480.76367,1732.598,5559.33545,693.840,
4480.85498,1731.598,5559.42676,693.840,
4480.94678,1731.598,5559.51855,693.840,
4481.03809,1731.598,5559.60986,692.840,
4481.12988,1730.598,5559.70166,692.840,
4481.22119,1730.598,5559.79297,691.840,
4481.31299,1730.598,5559.88477,691.840,
4481.40430,1730.598,5559.97607,691.840,
4481.49561,1729.598,5560.06787,691.840,
4481.58740,1730.598,5560.15918,691.840,
4481.67871,1729.598,5560.25049,691.840,
4481.77051,1729.598,5560.34229,690.840,
4481.86182,1728.598,5560.43359,690.840,
4481.95361,1729.598,5560.52539,689.840,
4482.04492,1728.598,5560.61670,690.840,
4482.13623,1728.598,5560.70850,689.840,
4482.22803,1728.598,5560.79980,689.840,
4482.31934,1727.598,5560.89111,689.840,
4482.41113,1727.598,5560.98291,689.840,
4482.50244,1727.598,5561.07422,689.840,
4482.59424,1726.598,5561.16602,689.840,
4482.68555,1726.598,5561.25732,688.840,
4482.77686,1726.598,5561.34912,688.840,
4482.86865,1726.598,5561.44043,688.840,
4482.95996,1725.598,5561.53174,688.840,
4483.05176,1725.598,5561.62354,688.840,
4483.14307,1725.598,5561.71484,687.840,
4483.23486,1725.598,5561.80664,687.840,
4483.32617,1724.598,5561.89795,687.840,
4483.41748,1724.598,5561.98975,687.840,
4483.50928,1723.598,5562.08105,686.840,
4483.60059,1723.598,5562.17285,686.840,
4483.69238,1723.598,5562.26416,686.840,
4483.78369,1723.598,5562.35547,686.840,
4483.87549,1723.598,5562.44727,687.840,
4483.96680,1723.598,5562.53857,686.840,
4484.05859,1722.598,5562.63037,686.840,
4484.14990,1722.598,5562.72168,685.840,
4484.24121,1721.598,5562.81348,685.840,
4484.33301,1721.598,5562.90479,685.840,
4484.42432,1721.598,5562.99609,685.840,
4484.51611,1721.598,5563.08789,684.840,
4484.60742,1721.598,5563.17920,684.840,
4484.69922,1721.598,5563.27100,684.840,
4484.79053,1720.598,5563.36230,684.840,
4484.88184,1720.598,5563.45410,684.840,
4484.97363,1719.598,5563.54541,683.840,
4485.06494,1719.598,5563.63672,683.840,
4485.15674,1719.598,5563.72852,683.840,
4485.24805,1719.598,5563.81982,683.840,
4485.33984,1718.598,5563.91162,682.840,
4485.43115,1718.598,5564.00293,683.840,
4485.52246,1718.598,5564.09473,682.840,
4485.61426,1718.598,5564.18604,682.840,
4485.70557,1717.598,5564.27783,682.840,
4485.79736,1716.598,5564.36914,681.840,
4485.88867,1717.598,5564.46045,681.840,
4485.98047,1716.598,5564.55225,681.840,
4486.07178,1716.598,5564.64355,681.840,
4486.16357,1717.598,5564.73535,681.840,
4486.25488,1715.598,5564.82666,680.840,
4486.34619,1716.598,5564.91846,680.840,
4486.43799,1716.598,5565.00977,680.840,
4486.52930,1715.598,5565.10107,680.840,
4486.62109,1715.598,5565.19287,679.840,
4486.71240,1714.598,5565.28418,679.840,
4486.80420,1714.598,5565.37598,680.840,
4486.89551,1714.598,5565.46729,679.840,
4486.98682,1714.598,5565.55908,679.840,
4487.07861,1713.598,5565.65039,679.840,
4487.16992,1713.598,5565.74170,678.840,
4487.26172,1713.598,5565.83350,679.840,
4487.35303,1713.598,5565.92480,679.840,
4487.44482,1712.598,5566.01660,678.840,
4487.53613,1712.598,5566.10791,678.840,
4487.62744,1713.598,5566.19971,678.840,
4487.71924,1711.598,5566.29102,677.840,
4487.81055,1711.598,5566.38281,677.840,
4487.90234,1711.598,5566.47412,677.840,
4487.99365,1711.598,5566.56543,677.840,
4488.08545,1710.598,5566.65723,676.840,
4488.17676,1710.598,5566.74854,676.840,
4488.26855,1710.598,5566.84033,677.840,
4488.35986,1709.598,5566.93164,676.840,
4488.45117,1709.598,5567.02344,676.840,
4488.54297,1709.598,5567.11475,676.840,
4488.63428,1709.598,5567.20605,676.840,
4488.72607,1708.598,5567.29785,675.840,
4488.81738,1708.598,5567.38916,675.840,
4488.90918,1708.598,5567.48096,675.840,
4489.00049,1708.598,5567.57227,675.840,
4489.09180,1708.598,5567.66406,674.840,
4489.18359,1707.598,5567.75537,674.840,
4489.27490,1707.598,5567.84668,674.840,
4489.36670,1707.598,5567.93848,674.840,
4489.45801,1706.598,5568.02979,673.840,
4489.54980,1706.598,5568.12158,673.840,
4489.64111,1706.598,5568.21289,673.840,
4489.73242,1706.598,5568.30469,674.840,
4489.82422,1705.598,5568.39600,673.840,
4489.91553,1705.598,5568.48730,672.840,
4490.00732,1705.598,5568.57910,673.840,
4490.09863,1704.598,5568.67041,673.840,
4490.19043,1704.598,5568.76221,672.840,
4490.28174,1704.598,5568.85352,672.840,
4490.37354,1703.598,5568.94531,671.840,
4490.46484,1703.598,5569.03662,672.840,
4490.55615,1704.598,5569.12842,671.840,
4490.64795,1703.598,5569.21973,670.840,
4490.73926,1702.598,5569.31104,669.840,
4490.83105,1702.598,5569.40283,669.840,
4490.92236,1702.598,5569.49414,669.840,
4491.01416,1702.598,5569.58594,668.840,
4491.10547,1701.598,5569.67725,668.840,
4491.19678,1701.598,5569.76904,669.840,
4491.28857,1701.598,5569.86035,668.840,
4491.37988,1701.598,5569.95166,668.840,
4491.47168,1701.598,5570.04346,668.840,
4491.56299,1700.598,5570.13477,668.840,
4491.65479,1700.598,5570.22656,668.840,
4491.74609,1700.598,5570.31787,668.840,
4491.83740,1699.598,5570.40967,668.840,
4491.92920,1699.598,5570.50098,667.840,
4492.02051,1699.598,5570.59229,668.840,
4492.11230,1699.598,5570.68408,667.840,
4492.20361,1698.598,5570.77539,668.840,
4492.29541,1698.598,5570.86719,667.840,
4492.38672,1698.598,5570.95850,667.840,
4492.47852,1698.598,5571.05029,667.840,
4492.56982,1697.598,5571.14160,667.840,
4492.66113,1697.598,5571.23340,667.840,
4492.75293,1696.598,5571.32471,666.840,
4492.84424,1696.598,5571.41602,667.840,
4492.93604,1696.598,5571.50781,666.840,
4493.02734,1695.598,5571.59912,667.840,
4493.11914,1695.598,5571.69092,667.840,
4493.21045,1695.598,5571.78223,667.840,
4493.30176,1695.598,5571.87402,667.840,
4493.39355,1694.598,5571.96533,666.840,
4493.48486,1695.598,5572.05664,666.840,
4493.57666,1694.598,5572.14844,666.840,
4493.66797,1694.598,5572.23975,666.840,
4493.75977,1693.598,5572.33154,665.840,
4493.85107,1694.598,5572.42285,665.840,
4493.94238,1693.598,5572.51465,665.840,
4494.03418,1693.598,5572.60596,664.840,
4494.12549,1693.598,5572.69727,665.840,
4494.21729,1692.598,5572.78906,664.840,
4494.30859,1692.598,5572.88037,663.840,
4494.40039,1691.598,5572.97217,663.840,
4494.49170,1691.598,5573.06348,663.840,
4494.58350,1691.598,5573.15527,663.840,
4494.67480,1691.598,5573.24658,663.840,
4494.76611,1690.598,5573.33838,662.840,
4494.85791,1690.598,5573.42969,662.840,
4494.94922,1690.598,5573.52100,662.840,
4495.04102,1689.598,5573.61279,662.840,
4495.13232,1689.598,5573.70410,662.840,
4495.22412,1689.598,5573.79590,661.840,
4495.31543,1689.598,5573.88721,661.840,
4495.40674,1689.598,5573.97900,661.840,
4495.49854,1688.598,5574.07031,660.840,
4495.58984,1688.598,5574.16162,661.840,
4495.68164,1687.598,5574.25342,660.840,
4495.77295,1688.598,5574.34473,660.840,
4495.86475,1687.598,5574.43652,660.840,
4495.95605,1687.598,5574.52783,659.840,
4496.04736,1687.598,5574.61963,660.840,
4496.13916,1687.598,5574.71094,659.840,
4496.23047,1686.598,5574.80225,659.840,
4496.32227,1686.598,5574.89404,659.840,
4496.41357,1686.598,5574.98535,659.840,
4496.50537,1686.598,5575.07715,658.840,
4496.59668,1685.598,5575.16846,658.840,
4496.68799,1685.598,5575.26025,658.840,
4496.77979,1684.598,5575.35156,658.840,
4496.87109,1685.598,5575.44336,657.840,
4496.96289,1684.598,5575.53467,657.840,
4497.05420,1684.598,5575.62598,658.840,
4497.14600,1683.598,5575.71777,657.840,
4497.23730,1684.598,5575.80908,657.840,
4497.32910,1683.598,5575.90088,657.840,
4497.42041,1682.598,5575.99219,657.840,
4497.51172,1682.598,5576.08398,656.840,
4497.60352,1682.598,5576.17529,656.840,
4497.69482,1681.598,5576.26660,656.840,
4497.78662,1680.598,5576.35840,655.840,
4497.87793,1680.598,5576.44971,655.840,
4497.96973,1679.598,5576.54150,655.840,
4498.06104,1679.598,5576.63281,655.840,
4498.15234,1679.598,5576.72461,655.840,
4498.24414,1679.598,5576.81592,655.840,
4498.33545,1678.598,5576.90723,654.840,
4498.42725,1678.598,5576.99902,654.840,
4498.51855,1678.598,5577.09033,655.840,
4498.61035,1678.598,5577.18213,654.840,
4498.70166,1679.598,5577.27344,654.840,
4498.79297,1678.598,5577.36523,653.840,
4498.88477,1678.598,5577.45654,653.840,
4498.97607,1678.598,5577.54834,653.840,
4499.06787,1678.598,5577.63965,653.840,
4499.15918,1677.598,5577.73096,652.840,
4499.25098,1677.598,5577.82275,652.840,
4499.34229,1678.598,5577.91406,652.840,
4499.43408,1677.598,5578.00586,652.840,
4499.52539,1677.598,5578.09717,651.840,
4499.61670,1677.598,5578.18896,652.840,
4499.70850,1676.598,5578.28027,651.840,
4499.79980,1675.598,5578.37158,651.840,
4499.89160,1675.598,5578.46338,651.840,
4499.98291,1674.598,5578.55469,652.840,
4500.07471,1673.598,5578.64648,651.840,
4500.16602,1672.598,5578.73779,650.840,
4500.25732,1672.598,5578.82959,651.840,
4500.34912,1671.598,5578.92090,650.840,
4500.44043,1671.598,5579.01221,650.840,
4500.53223,1671.598,5579.10400,650.840,
4500.62354,1671.598,5579.19531,649.840,
4500.71533,1671.598,5579.28711,650.840,
4500.80664,1672.598,5579.37842,649.840,
4500.89795,1672.598,5579.47021,649.840,
4500.98975,1671.598,5579.56152,649.840,
4501.08105,1671.598,5579.65332,648.840,
4501.17285,1671.598,5579.74463,648.840,
4501.26416,1671.598,5579.83594,648.840,
4501.35596,1671.598,5579.92773,648.840,
4501.44727,1670.598,5580.01904,648.840,
4501.53906,1670.598,5580.11084,648.840,
4501.63037,1670.598,5580.20215,648.840,
4501.72168,1670.598,5580.29395,647.840,
4501.81348,1670.598,5580.38525,647.840,
4501.90479,1669.598,5580.47656,647.840,
4501.99658,1669.598,5580.56836,646.840,
4502.08789,1669.598,5580.65967,647.840,
4502.17969,1668.598,5580.75146,646.840,
4502.27100,1670.598,5580.84277,646.840,
4502.36230,1669.598,5580.93457,646.840,
4502.45410,1668.598,5581.02588,645.840,
4502.54541,1667.598,5581.11719,645.840,
4502.63721,1668.598,5581.20898,645.840,
4502.72852,1667.598,5581.30029,644.840,
4502.82031,1667.598,5581.39209,645.840,
4502.91162,1667.598,5581.48340,645.840,
4503.00293,1666.598,5581.57520,645.840,
4503.09473,1666.598,5581.66650,645.840,
4503.18604,1666.598,5581.75781,643.840,
4503.27783,1665.598,5581.84961,643.840,
4503.36914,1665.598,5581.94092,643.840,
4503.46094,1665.598,5582.03271,644.840,
4503.55225,1664.598,5582.12402,643.840,
4503.64404,1664.598,5582.21582,643.840,
4503.73535,1665.598,5582.30713,643.840,
4503.82666,1664.598,5582.39893,642.840,
4503.91846,1664.598,5582.49023,643.840,
4504.00977,1663.598,5582.58154,642.840,
4504.10156,1663.598,5582.67334,642.840,
4504.19287,1663.598,5582.76465,642.840,
4504.28467,1662.598,5582.85645,642.840,
4504.37598,1663.598,5582.94775,643.840,
4504.46729,1662.598,5583.03955,641.840,
4504.55908,1661.598,5583.13086,642.840,
4504.65039,1661.598,5583.22217,641.840,
4504.74219,1661.598,5583.31396,641.840,
4504.83350,1661.598,5583.40527,642.840,
4504.92529,1661.598,5583.49707,641.840,
4505.01660,1661.598,5583.58838,640.840,
4505.10791,1660.598,5583.68018,641.840,
4505.19971,1660.598,5583.77148,641.840,
4505.29102,1660.598,5583.86279,640.840,
4505.38281,1659.598,5583.95459,640.840,
4505.47412,1659.598,5584.04590,640.840,
4505.56592,1659.598,5584.13770,639.840,
4505.65723,1659.598,5584.22900,639.840,
4505.74902,1658.598,5584.32080,639.840,
4505.84033,1658.598,5584.41211,640.840,
4505.93164,1658.598,5584.50391,639.840,
4506.02344,1658.598,5584.59521,639.840,
4506.11475,1657.598,5584.68652,639.840,
4506.20654,1657.598,5584.77832,639.840,
4506.29785,1656.598,5584.86963,639.840,
4506.38965,1656.598,5584.96143,638.840,
4506.48096,1656.598,5585.05273,638.840,
4506.57227,1656.598,5585.14453,637.840,
4506.66406,1656.598,5585.23584,637.840,
4506.75537,1656.598,5585.32715,637.840,
4506.84717,1655.598,5585.41895,636.840,
4506.93848,1655.598,5585.51025,637.840,
4507.03027,1655.598,5585.60205,637.840,
4507.12158,1654.598,5585.69336,636.840,
4507.21289,1654.598,5585.78516,635.840,
4507.30469,1654.598,5585.87646,636.840,
4507.39600,1654.598,5585.96777,635.840,
4507.48779,1653.598,5586.05957,636.840,
4507.57910,1653.598,5586.15088,635.840,
4507.67090,1652.598,5586.24268,635.840,
4507.76221,1652.598,5586.33398,635.840,
4507.85352,1652.598,5586.42578,634.840,
4507.94531,1652.598,5586.51709,634.840,
4508.03662,1652.598,5586.60889,634.840,
4508.12842,1652.598,5586.70020,634.840,
4508.21973,1651.598,5586.79150,634.840,
4508.31152,1651.598,5586.88330,633.840,
4508.40283,1651.598,5586.97461,633.840,
4508.49463,1650.598,5587.06641,633.840,
4508.58594,1649.598,5587.15771,633.840,
4508.67725,1649.598,5587.24951,633.840,
4508.76904,1649.598,5587.34082,633.840,
4508.86035,1649.598,5587.43213,632.840,
4508.95215,1649.598,5587.52393,633.840,
4509.04346,1649.598,5587.61523,632.840,
4509.13525,1648.598,5587.70703,632.840,
4509.22656,1648.598,5587.79834,632.840,
4509.31787,1648.598,5587.89014,631.840,
4509.40967,1647.598,5587.98145,632.840,
4509.50098,1647.598,5588.07275,631.840,
4509.59277,1647.598,5588.16455,631.840,
4509.68408,1647.598,5588.25586,631.840,
4509.77588,1647.598,5588.34766,631.840,
4509.86719,1646.598,5588.43896,630.840,
4509.95850,1646.598,5588.53076,630.840,
4510.05029,1645.598,5588.62207,630.840,
4510.14160,1646.598,5588.71387,630.840,
4510.23340,1645.598,5588.80518,630.840,
4510.32471,1645.598,5588.89648,630.840,
4510.41650,1644.598,5588.98828,630.840,
4510.50781,1644.598,5589.07959,629.840,
4510.59961,1644.598,5589.17139,629.840,
4510.69092,1644.598,5589.26270,629.840,
4510.78223,1644.598,5589.35449,629.840,
4510.87402,1643.598,5589.44580,628.840,
4510.96533,1642.598,5589.53711,629.840,
4511.05713,1643.598,5589.62891,628.840,
4511.14844,1643.598,5589.72021,628.840,
4511.24023,1642.598,5589.81201,628.840,
4511.33154,1642.598,5589.90332,627.840,
4511.42285,1642.598,5589.99512,627.840,
4511.51465,1641.598,5590.08643,627.840,
4511.60596,1641.598,5590.17773,626.840,
4511.69775,1641.598,5590.26953,627.840,
4511.78906,1640.598,5590.36084,626.840,
4511.88086,1640.598,5590.45264,626.840,
4511.97217,1640.598,5590.54395,626.840,
4512.06348,1640.598,5590.63574,626.840,
4512.15527,1639.598,5590.72705,626.840,
4512.24658,1639.598,5590.81885,625.840,
4512.33838,1639.598,5590.91016,626.840,
4512.42969,1639.598,5591.00146,625.840,
4512.52148,1639.598,5591.09326,625.840,
4512.61279,1638.598,5591.18457,625.840,
4512.70459,1638.598,5591.27637,625.840,
4512.79590,1638.598,5591.36768,625.840,
4512.88721,1637.598,5591.45947,625.840,
4512.97900,1637.598,5591.55078,624.840,
4513.07031,1637.598,5591.64209,624.840,
4513.16211,1637.598,5591.73389,624.840,
4513.25342,1636.598,5591.82520,623.840,
4513.34521,1636.598,5591.91699,623.840,
4513.43652,1636.598,5592.00830,623.840,
4513.52783,1635.598,5592.10010,622.840,
4513.61963,1635.598,5592.19141,621.840,
4513.71094,1635.598,5592.28271,621.840,
4513.80273,1635.598,5592.37451,621.840,
4513.89404,1634.598,5592.46582,621.840,
4513.98584,1635.598,5592.55762,621.840,
4514.07715,1634.598,5592.64893,621.840,
4514.16846,1633.598,5592.74072,620.840,
4514.26025,1633.598,5592.83203,621.840,
4514.35156,1633.598,5592.92334,621.840,
4514.44336,1633.598,5593.01514,621.840,
4514.53467,1632.598,5593.10645,620.840,
4514.62646,1632.598,5593.19824,621.840,
4514.71777,1632.598,5593.28955,621.840,
4514.80957,1631.598,5593.38135,620.840,
4514.90088,1631.598,5593.47266,620.840,
4514.99219,1631.598,5593.56445,620.840,
4515.08398,1631.598,5593.65576,620.840,
4515.17529,1631.598,5593.74707,620.840,
4515.26709,1631.598,5593.83887,619.840,
4515.35840,1630.598,5593.93018,620.840,
4515.45020,1630.598,5594.02197,619.840,
4515.54150,1630.598,5594.11328,618.840,
4515.63281,1629.598,5594.20508,618.840,
4515.72461,1629.598,5594.29639,618.840,
4515.81592,1629.598,5594.38770,618.840,
4515.90771,1629.598,5594.47949,618.840,
4515.99902,1629.598,5594.57080,618.840,
4516.09082,1628.598,5594.66260,619.840,
4516.18213,1628.598,5594.75391,618.840,
4516.27344,1627.598,5594.84570,618.840,
4516.36523,1627.598,5594.93701,617.840,
4516.45654,1627.598,5595.02832,617.840,
4516.54834,1627.598,5595.12012,618.840,
4516.63965,1626.598,5595.21143,617.840,
4516.73145,1626.598,5595.30322,617.840,
4516.82275,1626.598,5595.39453,617.840,
4516.91455,1626.598,5595.48633,616.840,
4517.00586,1625.598,5595.57764,616.840,
4517.09717,1625.598,5595.66943,615.840,
4517.18896,1625.598,5595.76074,615.840,
4517.28027,1625.598,5595.85205,615.840,
4517.37207,1624.598,5595.94385,615.840,
4517.46338,1624.598,5596.03516,615.840,
4517.55518,1624.598,5596.12695,616.840,
4517.64648,1623.598,5596.21826,615.840,
4517.73779,1623.598,5596.31006,614.840,
4517.82959,1623.598,5596.40137,614.840,
4517.92090,1622.598,5596.49268,614.840,
4518.01270,1622.598,5596.58447,614.840,
4518.10400,1621.598,5596.67578,614.840,
4518.19580,1621.598,5596.76758,614.840,
4518.28711,1620.598,5596.85889,614.840,
4518.37842,1621.598,5596.95068,613.840,
4518.47021,1621.598,5597.04199,613.840,
4518.56152,1620.598,5597.13330,613.840,
4518.65332,1620.598,5597.22510,613.840,
4518.74463,1620.598,5597.31641,613.840,
4518.83643,1620.598,5597.40820,612.840,
4518.92773,1620.598,5597.49951,613.840,
4519.01953,1619.598,5597.59131,612.840,
4519.11084,1619.598,5597.68262,612.840,
4519.20215,1619.598,5597.77441,612.840,
4519.29395,1619.598,5597.86572,611.840,
4519.38525,1618.598,5597.95703,611.840,
4519.47705,1618.598,5598.04883,611.840,
4519.56836,1618.598,5598.14014,611.840,
4519.66016,1618.598,5598.23193,611.840,
4519.75146,1618.598,5598.32324,610.840,
4519.84277,1618.598,5598.41504,610.840,
4519.93457,1617.598,5598.50635,610.840,
4520.02588,1617.598,5598.59766,610.840,
4520.11768,1617.598,5598.68945,610.840,
4520.20898,1617.598,5598.78076,609.840,
4520.30078,1615.598,5598.87256,609.840,
4520.39209,1615.598,5598.96387,609.840,
4520.48340,1613.598,5599.05566,609.840,
4520.57520,1612.598,5599.14697,609.840,
4520.66650,1611.598,5599.23828,608.840,
4520.75830,1610.598,5599.33008,608.840,
4520.84961,1610.598,5599.42139,608.840,
4520.94141,1610.598,5599.51318,608.840,
4521.03271,1610.598,5599.60449,608.840,
4521.12402,1610.598,5599.69629,607.840,
4521.21582,1609.598,5599.78760,607.840,
4521.30713,1611.598,5599.87939,607.840,
4521.39893,1610.598,5599.97070,607.840,
4521.49023,1610.598,5600.06201,607.840,
4521.58203,1610.598,5600.15381,606.840,
4521.67334,1610.598,5600.24512,606.840,
4521.76514,1610.598,5600.33691,606.840,
4521.85645,1610.598,5600.42822,606.840,
4521.94775,1610.598,5600.52002,606.840,
4522.03955,1610.598,5600.61133,605.840,
4522.13086,1610.598,5600.70264,605.840,
4522.22266,1610.598,5600.79443,605.840,
4522.31396,1610.598,5600.88574,605.840,
4522.40576,1610.598,5600.97754,604.840,
4522.49707,1609.598,5601.06885,604.840,
4522.58838,1609.598,5601.16064,605.840,
4522.68018,1609.598,5601.25195,604.840,
4522.77148,1609.598,5601.34326,604.840,
4522.86328,1609.598,5601.43506,604.840,
4522.95459,1608.598,5601.52637,603.840,
4523.04639,1607.598,5601.61816,604.840,
4523.13770,1608.598,5601.70947,603.840,
4523.22900,1607.598,5601.80127,603.840,
4523.32080,1607.598,5601.89258,603.840,
4523.41211,1607.598,5601.98438,603.840,
4523.50391,1606.598,5602.07568,603.840,
4523.59521,1606.598,5602.16699,602.840,
4523.68701,1606.598,5602.25879,603.840,
4523.77832,1606.598,5602.35010,602.840,
4523.87012,1605.598,5602.44189,602.840,
4523.96143,1605.598,5602.53320,601.840,
4524.05273,1605.598,5602.62500,602.840,
4524.14453,1605.598,5602.71631,601.840,
4524.23584,1605.598,5602.80762,601.840,
4524.32764,1605.598,5602.89941,601.840,
4524.41895,1604.598,5602.99072,601.840,
4524.51074,1603.598,5603.08252,600.840,
4524.60205,1603.598,5603.17383,600.840,
4524.69336,1603.598,5603.26563,600.840,
4524.78516,1603.598,5603.35693,600.840,
4524.87646,1603.598,5603.44824,600.840,
4524.96826,1603.598,5603.54004,600.840,
4525.05957,1602.598,5603.63135,600.840,
4525.15137,1602.598,5603.72314,599.840,
4525.24268,1602.598,5603.81445,599.840,
4525.33398,1601.598,5603.90625,599.840,
4525.42578,1601.598,5603.99756,599.840,
4525.51709,1601.598,5604.08936,599.840,
4525.60889,1600.598,5604.18066,599.840,
4525.70020,1601.598,5604.27197,598.840,
4525.79199,1600.598,5604.36377,598.840,
4525.88330,1600.598,5604.45508,598.840,
4525.97510,1599.598,5604.54688,597.840,
4526.06641,1599.598,5604.63818,597.840,
4526.15771,1599.598,5604.72998,597.840,
4526.24951,1599.598,5604.82129,597.840,
4526.34082,1598.598,5604.91260,598.840,
4526.43262,1599.598,5605.00439,597.840,
4526.52393,1598.598,5605.09570,597.840,
4526.61572,1597.598,5605.18750,597.840,
4526.70703,1597.598,5605.27881,596.840,
4526.79834,1597.598,5605.37061,597.840,
4526.89014,1597.598,5605.46191,596.840,
4526.98145,1596.598,5605.55322,595.840,
4527.07324,1597.598,5605.64502,596.840,
4527.16455,1597.598,5605.73633,595.840,
4527.25635,1595.598,5605.82813,595.840,
4527.34766,1596.598,5605.91943,595.840,
4527.43896,1595.598,5606.01123,595.840,
4527.53076,1595.598,5606.10254,594.840,
4527.62207,1595.598,5606.19385,594.840,
4527.71387,1595.598,5606.28564,595.840,
4527.80518,1594.598,5606.37695,595.840,
4527.89697,1594.598,5606.46875,594.840,
4527.98828,1594.598,5606.56006,595.840,
4528.08008,1593.598,5606.65186,594.840,
4528.17139,1593.598,5606.74316,593.840,
4528.26270,1593.598,5606.83496,593.840,
4528.35449,1593.598,5606.92627,594.840,
4528.44580,1593.598,5607.01758,593.840,
4528.53760,1592.598,5607.10938,593.840,
4528.62891,1592.598,5607.20068,593.840,
4528.72070,1592.598,5607.29248,593.840,
4528.81201,1591.598,5607.38379,592.840,
4528.90332,1591.598,5607.47559,592.840,
4528.99512,1591.598,5607.56689,592.840,
4529.08643,1591.598,5607.65820,592.840,
4529.17822,1591.598,5607.75000,592.840,
4529.26953,1590.598,5607.84131,592.840,
4529.36133,1590.598,5607.93311,591.840,
4529.45264,1590.598,5608.02441,591.840,
4529.54395,1589.598,5608.11621,591.840,
4529.63574,1589.598,5608.20752,591.840,
4529.72705,1589.598,5608.29883,591.840,
4529.81885,1589.598,5608.39063,590.840,
4529.91016,1588.598,5608.48193,590.840,
4530.00195,1588.598,5608.57373,590.840,
4530.09326,1589.598,5608.66504,590.840,
4530.18506,1587.598,5608.75684,589.840,
4530.27637,1588.598,5608.84814,589.840,
4530.36768,1588.598,5608.93994,589.840,
4530.45947,1587.598,5609.03125,589.840,
4530.55078,1586.598,5609.12256,589.840,
4530.64258,1587.598,5609.21436,588.840,
4530.73389,1586.598,5609.30566,589.840,
4530.82568,1586.598,5609.39746,588.840,
4530.91699,1585.598,5609.48877,588.840,
4531.00830,1585.598,5609.58057,588.840,
4531.10010,1585.598,5609.67188,588.840,
4531.19141,1585.598,5609.76318,588.840,
4531.28320,1585.598,5609.85498,588.840,
4531.37451,1583.598,5609.94629,588.840,
4531.46631,1583.598,5610.03809,587.840,
4531.55762,1584.598,5610.12939,587.840,
4531.64893,1583.598,5610.22119,587.840,
4531.74072,1582.598,5610.31250,587.840,
4531.83203,1582.598,5610.40381,586.840,
4531.92383,1582.598,5610.49561,586.840,
4532.01514,1582.598,5610.58691,586.840,
4532.10693,1581.598,5610.67871,586.840,
4532.19824,1581.598,5610.77002,586.840,
4532.29004,1581.598,5610.86182,586.840,
4532.38135,1581.598,5610.95313,586.840,
4532.47266,1580.598,5611.04492,585.840,
4532.56445,1580.598,5611.13623,585.840,
4532.65576,1580.598,5611.22754,585.840,
4532.74756,1580.598,5611.31934,585.840,
4532.83887,1579.598,5611.41064,585.840,
4532.93066,1579.598,5611.50244,585.840,
4533.02197,1580.598,5611.59375,585.840,
4533.11328,1579.598,5611.68555,584.840,
4533.20508,1578.598,5611.77686,584.840,
4533.29639,1579.598,5611.86816,584.840,
4533.38818,1578.598,5611.95996,583.840,
4533.47949,1578.598,5612.05127,583.840,
4533.57129,1578.598,5612.14307,583.840,
4533.66260,1577.598,5612.23438,583.840,
4533.75391,1577.598,5612.32617,583.840,
4533.84570,1577.598,5612.41748,583.840,
4533.93701,1577.598,5612.50879,583.840,
4534.02881,1576.598,5612.60059,583.840,
4534.12012,1576.598,5612.69189,583.840,
4534.21191,1576.598,5612.78369,582.840,
4534.30322,1575.598,5612.87500,582.840,
4534.39453,1575.598,5612.96680,582.840,
4534.48633,1575.598,5613.05811,581.840,
4534.57764,1575.598,5613.14990,581.840,
4534.66943,1575.598,5613.24121,581.840,
4534.76074,1574.598,5613.33252,581.840,
4534.85254,1574.598,5613.42432,581.840,
4534.94385,1574.598,5613.51563,581.840,
4535.03564,1573.598,5613.60742,580.840,
4535.12695,1573.598,5613.69873,581.840,
4535.21826,1574.598,5613.79053,580.840,
4535.31006,1573.598,5613.88184,580.840,
4535.40137,1572.598,5613.97314,580.840,
4535.49316,1573.598,5614.06494,579.840,
4535.58447,1572.598,5614.15625,579.840,
4535.67627,1572.598,5614.24805,579.840,
4535.76758,1571.598,5614.33936,579.840,
4535.85889,1571.598,5614.43115,579.840,
4535.95068,1572.598,5614.52246,579.840,
4536.04199,1571.598,5614.61377,578.840,
4536.13379,1571.598,5614.70557,578.840,
4536.22510,1570.598,5614.79688,579.840,
4536.31689,1570.598,5614.88867,579.840,
4536.40820,1570.598,5614.97998,579.840,
4536.49951,1569.598,5615.07178,579.840,
4536.59131,1569.598,5615.16309,579.840,
4536.68262,1569.598,5615.25488,579.840,
4536.77441,1568.598,5615.34619,579.840,
4536.86572,1568.598,5615.43750,579.840,
4536.95752,1568.598,5615.52930,578.840,
4537.04883,1568.598,5615.62061,578.840,
4537.14063,1567.598,5615.71240,578.840,
4537.23193,1567.598,5615.80371,578.840,
4537.32324,1567.598,5615.89551,577.840,
4537.41504,1567.598,5615.98682,577.840,
4537.50635,1566.598,5616.07813,577.840,
4537.59814,1566.598,5616.16992,576.840,
4537.68945,1566.598,5616.26123,576.840,
4537.78125,1565.598,5616.35303,576.840,
4537.87256,1565.598,5616.44434,576.840,
4537.96387,1565.598,5616.53613,575.840,
4538.05566,1565.598,5616.62744,576.840,
4538.14697,1564.598,5616.71875,575.840,
4538.23877,1564.598,5616.81055,574.840,
4538.33008,1564.598,5616.90186,575.840,
4538.42188,1563.598,5616.99365,575.840,
4538.51318,1563.598,5617.08496,574.840,
4538.60449,1564.598,5617.17676,575.840,
4538.69629,1563.598,5617.26807,574.840,
4538.78760,1564.598,5617.35986,574.840,
4538.87939,1564.598,5617.45117,574.840,
4538.97070,1564.598,5617.54248,573.840,
4539.06250,1564.598,5617.63428,574.840,
4539.15381,1565.598,5617.72559,573.840,
4539.24561,1564.598,5617.81738,573.840,
4539.33691,1564.598,5617.90869,573.840,
4539.42822,1564.598,5618.00049,573.840,
4539.52002,1563.598,5618.09180,573.840,
4539.61133,1563.598,5618.18311,572.840,
4539.70313,1563.598,5618.27490,572.840,
4539.79443,1562.598,5618.36621,572.840,
4539.88623,1562.598,5618.45801,572.840,
4539.97754,1561.598,5618.54932,572.840,
4540.06885,1561.598,5618.64111,571.840,
4540.16064,1560.598,5618.73242,571.840,
4540.25195,1560.598,5618.82373,571.840,
4540.34375,1559.598,5618.91553,571.840,
4540.43506,1559.598,5619.00684,570.840,
4540.52686,1558.598,5619.09863,570.840,
4540.61816,1558.598,5619.18994,570.840,
4540.70947,1558.598,5619.28174,569.840,
4540.80127,1557.598,5619.37305,569.840,
4540.89258,1557.598,5619.46436,570.840,
4540.98438,1556.598,5619.55615,570.840,
4541.07568,1555.598,5619.64746,569.840,
4541.16748,1555.598,5619.73926,569.840,
4541.25879,1555.598,5619.83057,569.840,
4541.35059,1554.598,5619.92236,568.840,
4541.44189,1554.598,5620.01367,568.840,
4541.53320,1553.598,5620.10547,568.840,
4541.62500,1553.598,5620.19678,568.840,
4541.71631,1553.598,5620.28809,568.840,
4541.80811,1553.598,5620.37988,568.840,
4541.89941,1552.598,5620.47119,567.840,
4541.99121,1552.598,5620.56299,567.840,
4542.08252,1553.598,5620.65430,567.840,
4542.17383,1552.598,5620.74609,567.840,
4542.26563,1552.598,5620.83740,567.840,
4542.35693,1553.598,5620.92871,567.840,
4542.44873,1552.598,5621.02051,567.840,
4542.54004,1552.598,5621.11182,566.840,
4542.63184,1551.598,5621.20361,566.840,
4542.72314,1551.598,5621.29492,566.840,
4542.81445,1551.598,5621.38672,565.840,
4542.90625,1551.598,5621.47803,566.840,
4542.99756,1550.598,5621.56934,565.840,
4543.08936,1551.598,5621.66113,565.840,
4543.18066,1550.598,5621.75244,565.840,
4543.27246,1551.598,5621.84424,565.840,
4543.36377,1551.598,5621.93555,565.840,
4543.45557,1550.598,5622.02734,565.840,
4543.54688,1549.598,5622.11865,564.840,
4543.63818,1549.598,5622.21045,564.840,
4543.72998,1549.598,5622.30176,564.840,
4543.82129,1549.598,5622.39307,564.840,
4543.91309,1549.598,5622.48486,564.840,
4544.00439,1548.598,5622.57617,563.840,
4544.09619,1548.598,5622.66797,563.840,
4544.18750,1548.598,5622.75928,563.840,
4544.27881,1547.598,5622.85107,563.840,
4544.37061,1547.598,5622.94238,563.840,
4544.46191,1547.598,5623.03369,563.840,
4544.55371,1546.598,5623.12549,562.840,
4544.64502,1546.598,5623.21680,562.840,
4544.73682,1547.598,5623.30859,562.840,
4544.82813,1546.598,5623.39990,562.840,
4544.91943,1546.598,5623.49170,561.840,
4545.01123,1545.598,5623.58301,561.840,
4545.10254,1545.598,5623.67432,562.840,
4545.19434,1545.598,5623.76611,561.840,
4545.28564,1545.598,5623.85742,561.840,
4545.37744,1544.598,5623.94922,561.840,
4545.46875,1544.598,5624.04053,561.840,
4545.56006,1544.598,5624.13232,561.840,
4545.65186,1544.598,5624.22363,561.840,
4545.74316,1543.598,5624.31543,560.840,
4545.83496,1543.598,5624.40674,560.840,
4545.92627,1543.598,5624.49805,560.840,
4546.01807,1542.598,5624.58984,560.840,
4546.10938,1542.598,5624.68115,560.840,
4546.20117,1542.598,5624.77295,559.840,
4546.29248,1541.598,5624.86426,560.840,
4546.38379,1542.598,5624.95605,559.840,
4546.47559,1541.598,5625.04736,558.840,
4546.56689,1541.598,5625.13867,559.840,
4546.65869,1541.598,5625.23047,559.840,
4546.75000,1540.598,5625.32178,558.840,
4546.84180,1540.598,5625.41357,559.840,
4546.93311,1539.598,5625.50488,558.840,
4547.02441,1539.598,5625.59668,558.840,
4547.11621,1539.598,5625.68799,557.840,
4547.20752,1539.598,5625.77930,558.840,
4547.29932,1539.598,5625.87109,557.840,
4547.39063,1539.598,5625.96240,557.840,
4547.48242,1539.598,5626.05420,557.840,
4547.57373,1539.598,5626.14551,557.840,
4547.66504,1539.598,5626.23730,556.840,
4547.75684,1538.598,5626.32861,556.840,
4547.84814,1538.598,5626.42041,556.840,
4547.93994,1537.598,5626.51172,556.840,
4548.03125,1537.598,5626.60303,556.840,
4548.12305,1536.598,5626.69482,556.840,
4548.21436,1536.598,5626.78613,556.840,
4548.30615,1536.598,5626.87793,556.840,
4548.39746,1536.598,5626.96924,555.840,
4548.48877,1535.598,5627.06104,555.840,
4548.58057,1535.598,5627.15234,555.840,
4548.67188,1535.598,5627.24365,555.840,
4548.76367,1534.598,5627.33545,555.840,
4548.85498,1534.598,5627.42676,555.840,
4548.94678,1534.598,5627.51855,554.840,
4549.03809,1534.598,5627.60986,554.840,
4549.12939,1535.598,5627.70166,554.840,
4549.22119,1533.598,5627.79297,554.840,
4549.31250,1533.598,5627.88428,553.840,
4549.40430,1533.598,5627.97607,554.840,
4549.49561,1533.598,5628.06738,553.840,
4549.58740,1533.598,5628.15918,553.840,
4549.67871,1533.598,5628.25049,553.840,
4549.77002,1532.598,5628.34229,553.840,
4549.86182,1532.598,5628.43359,553.840,
4549.95313,1531.598,5628.52539,552.840,
4550.04492,1531.598,5628.61670,553.840,
4550.13623,1531.598,5628.70801,552.840,
4550.22803,1531.598,5628.79980,552.840,
4550.31934,1530.598,5628.89111,552.840,
4550.41113,1530.598,5628.98291,551.840,
4550.50244,1530.598,5629.07422,551.840,
4550.59375,1531.598,5629.16602,551.840,
4550.68555,1530.598,5629.25732,551.840,
4550.77686,1529.598,5629.34863,551.840,
4550.86865,1530.598,5629.44043,551.840,
4550.95996,1529.598,5629.53174,550.840,
4551.05176,1528.598,5629.62354,551.840,
4551.14307,1528.598,5629.71484,550.840,
4551.23438,1528.598,5629.80664,551.840,
4551.32617,1527.598,5629.89795,550.840,
4551.41748,1527.598,5629.98926,549.840,
4551.50928,1527.598,5630.08105,549.840,
4551.60059,1527.598,5630.17236,550.840,
4551.69238,1527.598,5630.26416,549.840,
4551.78369,1526.598,5630.35547,550.840,
4551.87500,1526.598,5630.44727,549.840,
4551.96680,1526.598,5630.53857,549.840,
4552.05811,1527.598,5630.62988,549.840,
4552.14990,1525.598,5630.72168,548.840,
4552.24121,1525.598,5630.81299,548.840,
4552.33301,1525.598,5630.90479,548.840,
4552.42432,1525.598,5630.99609,548.840,
4552.51611,1524.598,5631.08789,548.840,
4552.60742,1524.598,5631.17920,547.840,
4552.69873,1524.598,5631.27100,548.840,
4552.79053,1524.598,5631.36230,548.840,
4552.88184,1523.598,5631.45361,547.840,
4552.97363,1523.598,5631.54541,547.840,
4553.06494,1522.598,5631.63672,547.840,
4553.15674,1522.598,5631.72852,546.840,
4553.24805,1522.598,5631.81982,546.840,
4553.33936,1522.598,5631.91162,546.840,
4553.43115,1522.598,5632.00293,546.840,
4553.52246,1522.598,5632.09424,545.840,
4553.61426,1521.598,5632.18604,545.840,
4553.70557,1521.598,5632.27734,546.840,
4553.79736,1521.598,5632.36914,545.840,
4553.88867,1521.598,5632.46045,545.840,
4553.97998,1520.598,5632.55225,545.840,
4554.07178,1520.598,5632.64355,544.840,
4554.16309,1520.598,5632.73486,544.840,
4554.25488,1520.598,5632.82666,544.840,
4554.34619,1519.598,5632.91797,544.840,
4554.43799,1519.598,5633.00977,544.840,
4554.52930,1519.598,5633.10107,544.840,
4554.62109,1518.598,5633.19287,544.840,
4554.71240,1518.598,5633.28418,543.840,
4554.80371,1518.598,5633.37598,543.840,
4554.89551,1518.598,5633.46729,543.840,
4554.98682,1518.598,5633.55859,542.840,
4555.07861,1518.598,5633.65039,543.840,
4555.16992,1517.598,5633.74170,543.840,
4555.26172,1517.598,5633.83350,543.840,
4555.35303,1517.598,5633.92480,542.840,
4555.44434,1517.598,5634.01660,542.840,
4555.53613,1516.598,5634.10791,542.840,
4555.62744,1516.598,5634.19922,542.840,
4555.71924,1516.598,5634.29102,542.840,
4555.81055,1516.598,5634.38232,542.840,
4555.90234,1515.598,5634.47412,541.840,
4555.99365,1515.598,5634.56543,542.840,
4556.08496,1514.598,5634.65723,541.840,
4556.17676,1514.598,5634.74854,541.840,
4556.26807,1514.598,5634.83984,541.840,
4556.35986,1514.598,5634.93164,541.840,
4556.45117,1514.598,5635.02295,540.840,
4556.54297,1513.598,5635.11475,540.840,
4556.63428,1513.598,5635.20605,540.840,
4556.72607,1512.598,5635.29785,540.840,
4556.81738,1512.598,5635.38916,540.840,
4556.90869,1513.598,5635.48096,539.840,
4557.00049,1511.598,5635.57227,539.840,
4557.09180,1511.598,5635.66357,540.840,
4557.18359,1512.598,5635.75537,539.840,
4557.27490,1511.598,5635.84668,539.840,
4557.36670,1511.598,5635.93848,539.840,
4557.45801,1511.598,5636.02979,539.840,
4557.54932,1510.598,5636.12158,540.840,
4557.64111,1510.598,5636.21289,540.840,
4557.73242,1509.598,5636.30420,540.840,
4557.82422,1509.598,5636.39600,540.840,
4557.91553,1510.598,5636.48730,540.840,
4558.00732,1509.598,5636.57910,540.840,
4558.09863,1509.598,5636.67041,540.840,
4558.18994,1509.598,5636.76221,540.840,
4558.28174,1508.598,5636.85352,540.840,
4558.37305,1508.598,5636.94482,540.840,
4558.46484,1508.598,5637.03662,540.840,
4558.55615,1508.598,5637.12793,540.840,
4558.64795,1507.598,5637.21973,539.840,
4558.73926,1507.598,5637.31104,538.840,
4558.83057,1507.598,5637.40283,539.840,
4558.92236,1507.598,5637.49414,538.840,
4559.01367,1506.598,5637.58594,537.840,
4559.10547,1506.598,5637.67725,537.840,
4559.19678,1506.598,5637.76855,537.840,
4559.28857,1506.598,5637.86035,536.840,
4559.37988,1506.598,5637.95166,536.840,
4559.47168,1506.598,5638.04346,536.840,
4559.56299,1505.598,5638.13477,535.840,
4559.65430,1505.598,5638.22656,535.840,
4559.74609,1505.598,5638.31787,535.840,
4559.83740,1505.598,5638.40918,535.840,
4559.92920,1504.598,5638.50098,535.840,
4560.02051,1503.598,5638.59229,536.840,
4560.11230,1503.598,5638.68408,536.840,
4560.20361,1503.598,5638.77539,536.840,
4560.29492,1502.598,5638.86719,536.840,
4560.38672,1502.598,5638.95850,536.840,
4560.47803,1503.598,5639.04980,536.840,
4560.56982,1502.598,5639.14160,536.840,
4560.66113,1502.598,5639.23291,536.840,
4560.75293,1502.598,5639.32471,535.840,
4560.84424,1502.598,5639.41602,535.840,
4560.93555,1501.598,5639.50781,535.840,
4561.02734,1501.598,5639.59912,534.840,
4561.11865,1501.598,5639.69092,533.840,
4561.21045,1501.598,5639.78223,534.840,
4561.30176,1500.598,5639.87354,533.840,
4561.39355,1500.598,5639.96533,533.840,
4561.48486,1500.598,5640.05664,533.840,
4561.57666,1499.598,5640.14844,533.840,
4561.66797,1499.598,5640.23975,531.840,
4561.75928,1499.598,5640.33154,531.840,
4561.85107,1498.598,5640.42285,531.840,
4561.94238,1498.598,5640.51416,531.840,
4562.03418,1497.598,5640.60596,531.840,
4562.12549,1496.598,5640.69727,530.840,
4562.21729,1496.598,5640.78906,530.840,
4562.30859,1496.598,5640.88037,530.840,
4562.39990,1495.598,5640.97217,530.840,
4562.49170,1495.598,5641.06348,529.840,
4562.58301,1495.598,5641.15479,529.840,
4562.67480,1494.598,5641.24658,529.840,
4562.76611,1494.598,5641.33789,529.840,
4562.85791,1495.598,5641.42969,529.840,
4562.94922,1495.598,5641.52100,529.840,
4563.04053,1494.598,5641.61279,529.840,
4563.13232,1494.598,5641.70410,528.840,
4563.22363,1494.598,5641.79590,528.840,
4563.31543,1495.598,5641.88721,528.840,
4563.40674,1494.598,5641.97852,528.840,
4563.49854,1494.598,5642.07031,528.840,
4563.58984,1494.598,5642.16162,527.840,
4563.68164,1494.598,5642.25342,528.840,
4563.77295,1494.598,5642.34473,527.840,
4563.86426,1494.598,5642.43652,527.840,
4563.95605,1494.598,5642.52783,526.840,
4564.04736,1493.598,5642.61914,527.840,
4564.13916,1493.598,5642.71094,526.840,
4564.23047,1492.598,5642.80225,526.840,
4564.32227,1492.598,5642.89404,526.840,
4564.41357,1492.598,5642.98535,527.840,
4564.50488,1491.598,5643.07715,525.840,
4564.59668,1491.598,5643.16846,526.840,
4564.68799,1491.598,5643.25977,526.840,
4564.77979,1491.598,5643.35156,525.840,
4564.87109,1490.598,5643.44287,525.840,
4564.96289,1490.598,5643.53467,525.840,
4565.05420,1490.598,5643.62598,525.840,
4565.14551,1490.598,5643.71777,525.840,
4565.23730,1490.598,5643.80908,525.840,
4565.32861,1489.598,5643.90039,524.840,
4565.42041,1489.598,5643.99219,524.840,
4565.51172,1489.598,5644.08350,524.840,
4565.60352,1489.598,5644.17529,524.840,
4565.69482,1489.598,5644.26660,523.840,
4565.78662,1488.598,5644.35840,524.840,
4565.87793,1488.598,5644.44971,524.840,
4565.96924,1488.598,5644.54150,523.840,
4566.06104,1487.598,5644.63281,523.840,
4566.15234,1487.598,5644.72412,523.840,
4566.24414,1487.598,5644.81592,523.840,
4566.33545,1486.598,5644.90723,523.840,
4566.42725,1487.598,5644.99902,522.840,
4566.51855,1486.598,5645.09033,522.840,
4566.60986,1486.598,5645.18213,522.840,
4566.70166,1486.598,5645.27344,522.840,
4566.79297,1486.598,5645.36475,522.840,
4566.88477,1485.598,5645.45654,521.840,
4566.97607,1485.598,5645.54785,522.840,
4567.06787,1485.598,5645.63965,521.840,
4567.15918,1484.598,5645.73096,520.840,
4567.25049,1485.598,5645.82275,521.840,
4567.34229,1484.598,5645.91406,521.840,
4567.43359,1484.598,5646.00537,521.840,
4567.52539,1483.598,5646.09717,520.840,
4567.61670,1483.598,5646.18848,520.840,
4567.70850,1483.598,5646.28027,520.840,
4567.79980,1483.598,5646.37158,520.840,
4567.89160,1482.598,5646.46338,519.840,
4567.98291,1483.598,5646.55469,519.840,
4568.07422,1482.598,5646.64648,519.840,
4568.16602,1482.598,5646.73779,519.840,
4568.25732,1481.598,5646.82910,519.840,
4568.34912,1482.598,5646.92090,519.840,
4568.44043,1481.598,5647.01221,518.840,
4568.53223,1480.598,5647.10400,518.840,
4568.62354,1481.598,5647.19531,519.840,
4568.71484,1480.598,5647.28711,518.840,
4568.80664,1480.598,5647.37842,519.840,
4568.89795,1480.598,5647.46973,518.840,
4568.98975,1479.598,5647.56152,517.840,
4569.08105,1479.598,5647.65283,517.840,
4569.17285,1479.598,5647.74463,518.840,
4569.26416,1479.598,5647.83594,517.840,
4569.35547,1479.598,5647.92773,517.840,
4569.44727,1478.598,5648.01904,517.840,
4569.53857,1478.598,5648.11035,516.840,
4569.63037,1479.598,5648.20215,517.840,
4569.72168,1477.598,5648.29346,516.840,
4569.81348,1477.598,5648.38525,516.840,
4569.90479,1477.598,5648.47656,515.840,
4569.99658,1477.598,5648.56836,515.840,
4570.08789,1477.598,5648.65967,515.840,
4570.17920,1477.598,5648.75146,515.840,
4570.27100,1476.598,5648.84277,516.840,
4570.36230,1476.598,5648.93408,515.840,
4570.45410,1475.598,5649.02588,515.840,
4570.54541,1475.598,5649.11719,515.840,
4570.63721,1475.598,5649.20898,515.840,
4570.72852,1475.598,5649.30029,515.840,
4570.81982,1474.598,5649.39209,514.840,
4570.91162,1474.598,5649.48340,514.840,
4571.00293,1474.598,5649.57471,514.840,
4571.09473,1475.598,5649.66650,514.840,
4571.18604,1474.598,5649.75781,513.840,
4571.27783,1474.598,5649.84961,513.840,
4571.36914,1473.598,5649.94092,514.840,
4571.46045,1473.598,5650.03271,513.840,
4571.55225,1473.598,5650.12402,513.840,
4571.64355,1473.598,5650.21533,513.840,
4571.73535,1473.598,5650.30713,513.840,
4571.82666,1472.598,5650.39844,512.840,
4571.91846,1472.598,5650.49023,513.840,
4572.00977,1472.598,5650.58154,512.840,
4572.10107,1471.598,5650.67334,512.840,
4572.19287,1471.598,5650.76465,512.840,
4572.28418,1471.598,5650.85645,512.840,
4572.37598,1471.598,5650.94775,512.840,
4572.46729,1470.598,5651.03906,512.840,
4572.55908,1471.598,5651.13086,511.840,
4572.65039,1470.598,5651.22217,510.840,
4572.74219,1469.598,5651.31396,510.840,
4572.83350,1470.598,5651.40527,511.840,
4572.92480,1469.598,5651.49707,510.840,
4573.01660,1469.598,5651.58838,510.840,
4573.10791,1468.598,5651.67969,510.840,
4573.19971,1468.598,5651.77148,511.840,
4573.29102,1468.598,5651.86279,510.840,
4573.38281,1467.598,5651.95459,510.840,
4573.47412,1467.598,5652.04590,510.840,
4573.56543,1467.598,5652.13770,510.840,
4573.65723,1467.598,5652.22900,509.840,
4573.74854,1467.598,5652.32031,509.840,
4573.84033,1467.598,5652.41211,509.840,
4573.93164,1466.598,5652.50342,509.840,
4574.02344,1467.598,5652.59521,508.840,
4574.11475,1466.598,5652.68652,508.840,
4574.20605,1466.598,5652.77832,508.840,
4574.29785,1466.598,5652.86963,508.840,
4574.38916,1465.598,5652.96143,508.840,
4574.48096,1465.598,5653.05273,508.840,
4574.57227,1465.598,5653.14404,507.840,
4574.66406,1465.598,5653.23584,508.840,
4574.75537,1465.598,5653.32715,507.840,
4574.84717,1464.598,5653.41895,507.840,
4574.93848,1464.598,5653.51025,507.840,
4575.02979,1464.598,5653.60205,507.840,
4575.12158,1463.598,5653.69336,507.840,
4575.21289,1463.598,5653.78467,507.840,
4575.30469,1463.598,5653.87646,507.840,
4575.39600,1463.598,5653.96777,506.840,
4575.48779,1463.598,5654.05957,506.840,
4575.57910,1462.598,5654.15088,506.840,
4575.67041,1462.598,5654.24268,505.840,
4575.76221,1462.598,5654.33398,505.840,
4575.85352,1461.598,5654.42529,505.840,
4575.94531,1461.598,5654.51709,505.840,
4576.03662,1460.598,5654.60840,505.840,
4576.12842,1461.598,5654.70020,506.840,
4576.21973,1460.598,5654.79150,505.840,
4576.31104,1460.598,5654.88330,505.840,
4576.40283,1460.598,5654.97461,505.840,
4576.49414,1460.598,5655.06592,505.840,
4576.58594,1459.598,5655.15771,504.840,
4576.67725,1459.598,5655.24902,504.840,
4576.76904,1459.598,5655.34082,504.840,
4576.86035,1458.598,5655.43213,504.840,
4576.95215,1459.598,5655.52393,503.840,
4577.04346,1458.598,5655.61523,503.840,
4577.13477,1458.598,5655.70703,503.840,
4577.22656,1458.598,5655.79834,502.840,
4577.31787,1457.598,5655.88965,503.840,
4577.40967,1457.598,5655.98145,502.840,
4577.50098,1457.598,5656.07275,502.840,
4577.59277,1457.598,5656.16455,503.840,
4577.68408,1456.598,5656.25586,502.840,
4577.77539,1456.598,5656.34766,502.840,
4577.86719,1456.598,5656.43896,501.840,
4577.95850,1456.598,5656.53027,502.840,
4578.05029,1455.598,5656.62207,502.840,
4578.14160,1455.598,5656.71338,501.840,
4578.23340,1455.598,5656.80518,501.840,
4578.32471,1455.598,5656.89648,502.840,
4578.41602,1455.598,5656.98828,502.840,
4578.50781,1454.598,5657.07959,502.840,
4578.59912,1454.598,5657.17090,503.840,
4578.69092,1454.598,5657.26270,503.840,
4578.78223,1454.598,5657.35400,503.840,
4578.87402,1453.598,5657.44580,503.840,
4578.96533,1453.598,5657.53711,503.840,
4579.05713,1453.598,5657.62891,503.840,
4579.14844,1452.598,5657.72021,502.840,
4579.23975,1452.598,5657.81201,502.840,
4579.33154,1452.598,5657.90332,501.840,
4579.42285,1451.598,5657.99463,501.840,
4579.51465,1451.598,5658.08643,501.840,
4579.60596,1451.598,5658.17773,501.840,
4579.69775,1450.598,5658.26953,500.840,
4579.78906,1450.598,5658.36084,500.840,
4579.88037,1451.598,5658.45264,499.840,
4579.97217,1450.598,5658.54395,499.840,
4580.06348,1450.598,5658.63525,499.840,
4580.15527,1450.598,5658.72705,498.840,
4580.24658,1450.598,5658.81836,498.840,
4580.33838,1450.598,5658.91016,497.840,
4580.42969,1450.598,5659.00146,498.840,
4580.52100,1449.598,5659.09326,498.840,
4580.61279,1449.598,5659.18457,498.840,
4580.70410,1449.598,5659.27588,498.840,
4580.79590,1449.598,5659.36768,499.840,
4580.88721,1448.598,5659.45898,499.840,
4580.97900,1448.598,5659.55078,499.840,
4581.07031,1447.598,5659.64209,499.840,
4581.16211,1448.598,5659.73389,499.840,
4581.25342,1447.598,5659.82520,499.840,
4581.34473,1448.598,5659.91699,499.840,
4581.43652,1447.598,5660.00830,498.840,
4581.52783,1446.598,5660.09961,498.840,
4581.61963,1446.598,5660.19141,498.840,
4581.71094,1446.598,5660.28271,497.840,
4581.80273,1446.598,5660.37451,497.840,
4581.89404,1446.598,5660.46582,496.840,
4581.98535,1445.598,5660.55762,497.840,
4582.07715,1445.598,5660.64893,496.840,
4582.16846,1444.598,5660.74023,495.840,
4582.26025,1444.598,5660.83203,495.840,
4582.35156,1444.598,5660.92334,495.840,
4582.44336,1443.598,5661.01514,494.840,
4582.53467,1443.598,5661.10645,494.840,
4582.62598,1443.598,5661.19824,494.840,
4582.71777,1441.598,5661.28955,493.840,
4582.80908,1442.598,5661.38086,493.840,
4582.90088,1440.598,5661.47266,493.840,
4582.99219,1440.598,5661.56396,493.840,
4583.08398,1440.598,5661.65576,493.840,
4583.17529,1440.598,5661.74707,493.840,
4583.26660,1439.598,5661.83887,492.840,
4583.35840,1439.598,5661.93018,492.840,
4583.44971,1439.598,5662.02197,493.840,
4583.54150,1439.598,5662.11328,492.840,
4583.63281,1439.598,5662.20459,492.840,
4583.72461,1439.598,5662.29639,492.840,
4583.81592,1439.598,5662.38770,492.840,
4583.90771,1438.598,5662.47949,491.840,
4583.99902,1439.598,5662.57080,491.840,
4584.09033,1438.598,5662.66260,491.840,
4584.18213,1438.598,5662.75391,491.840,
4584.27344,1439.598,5662.84521,490.840,
4584.36523,1438.598,5662.93701,491.840,
4584.45654,1438.598,5663.02832,490.840,
4584.54834,1438.598,5663.12012,490.840,
4584.63965,1438.598,5663.21143,490.840,
4584.73096,1438.598,5663.30322,490.840,
4584.82275,1437.598,5663.39453,490.840,
4584.91406,1437.598,5663.48584,490.840,
4585.00586,1437.598,5663.57764,489.840,
4585.09717,1437.598,5663.66895,489.840,
4585.18896,1437.598,5663.76074,489.840,
4585.28027,1436.598,5663.85205,489.840,
4585.37158,1435.598,5663.94385,489.840,
4585.46338,1435.598,5664.03516,489.840,
4585.55469,1435.598,5664.12695,488.840,
4585.64648,1435.598,5664.21826,489.840,
4585.73779,1436.598,5664.30957,488.840,
4585.82959,1435.598,5664.40137,488.840,
4585.92090,1434.598,5664.49268,488.840,
4586.01270,1433.598,5664.58447,488.840,
4586.10400,1434.598,5664.67578,488.840,
4586.19531,1433.598,5664.76758,487.840,
4586.28711,1434.598,5664.85889,487.840,
4586.37842,1433.598,5664.95020,487.840,
4586.47021,1433.598,5665.04199,487.840,
4586.56152,1432.598,5665.13330,487.840,
4586.65332,1432.598,5665.22510,487.840,
4586.74463,1432.598,5665.31641,486.840,
4586.83594,1432.598,5665.40820,486.840,
4586.92773,1431.598,5665.49951,486.840,
4587.01904,1431.598,5665.59082,486.840,
4587.11084,1431.598,5665.68262,486.840,
4587.20215,1431.598,5665.77393,485.840,
4587.29395,1431.598,5665.86572,485.840,
4587.38525,1431.598,5665.95703,485.840,
4587.47656,1430.598,5666.04883,485.840,
4587.56836,1430.598,5666.14014,485.840,
4587.65967,1430.598,5666.23193,485.840,
4587.75146,1430.598,5666.32324,485.840,
4587.84277,1430.598,5666.41455,485.840,
4587.93457,1429.598,5666.50635,485.840,
4588.02588,1429.598,5666.59766,484.840,
4588.11768,1429.598,5666.68945,484.840,
4588.20898,1428.598,5666.78076,484.840,
4588.30029,1428.598,5666.87256,484.840,
4588.39209,1428.598,5666.96387,484.840,
4588.48340,1428.598,5667.05518,483.840,
4588.57520,1427.598,5667.14697,483.840,
4588.66650,1428.598,5667.23828,483.840,
4588.75830,1427.598,5667.33008,483.840,
4588.84961,1427.598,5667.42139,483.840,
4588.94092,1426.598,5667.51318,483.840,
4589.03271,1426.598,5667.60449,483.840,
4589.12402,1426.598,5667.69580,482.840,
4589.21582,1426.598,5667.78760,482.840,
4589.30713,1425.598,5667.87891,483.840,
4589.39893,1425.598,5667.97070,482.840,
4589.49023,1425.598,5668.06201,482.840,
4589.58154,1425.598,5668.15381,482.840,
4589.67334,1424.598,5668.24512,481.840,
4589.76465,1424.598,5668.33643,481.840,
4589.85645,1424.598,5668.42822,481.840,
4589.94775,1423.598,5668.51953,481.840,
4590.03955,1423.598,5668.61133,481.840,
4590.13086,1424.598,5668.70264,480.840,
4590.22266,1423.598,5668.79443,480.840,
4590.31396,1423.598,5668.88574,481.840,
4590.40527,1422.598,5668.97754,481.840,
4590.49707,1422.598,5669.06885,480.840,
4590.58838,1421.598,5669.16016,480.840,
4590.68018,1422.598,5669.25195,479.840,
4590.77148,1421.598,5669.34326,480.840,
4590.86328,1421.598,5669.43506,479.840,
4590.95459,1421.598,5669.52637,479.840,
4591.04590,1420.598,5669.61816,479.840,
4591.13770,1420.598,5669.70947,479.840,
4591.22900,1420.598,5669.80078,479.840,
4591.32080,1420.598,5669.89258,479.840,
4591.41211,1419.598,5669.98389,479.840,
4591.50391,1419.598,5670.07568,479.840,
4591.59521,1419.598,5670.16699,478.840,
4591.68652,1419.598,5670.25879,478.840,
4591.77832,1419.598,5670.35010,478.840,
4591.86963,1418.598,5670.44141,478.840,
4591.96143,1418.598,5670.53320,478.840,
4592.05273,1418.598,5670.62451,477.840,
4592.14453,1418.598,5670.71631,478.840,
4592.23584,1417.598,5670.80762,478.840,
4592.32764,1417.598,5670.89941,477.840,
4592.41895,1417.598,5670.99072,477.840,
4592.51025,1416.598,5671.08252,476.840,
4592.60205,1416.598,5671.17383,477.840,
4592.69336,1416.598,5671.26514,477.840,
4592.78516,1416.598,5671.35693,476.840,
4592.87646,1415.598,5671.44824,477.840,
4592.96826,1416.598,5671.54004,476.840,
4593.05957,1416.598,5671.63135,475.840,
4593.15088,1415.598,5671.72314,476.840,
4593.24268,1415.598,5671.81445,475.840,
4593.33398,1414.598,5671.90576,475.840,
4593.42578,1414.598,5671.99756,475.840,
4593.51709,1414.598,5672.08887,475.840,
4593.60889,1413.598,5672.18066,475.840,
4593.70020,1414.598,5672.27197,476.840,
4593.79150,1413.598,5672.36377,475.840,
4593.88330,1412.598,5672.45508,475.840,
4593.97461,1412.598,5672.54639,474.840,
4594.06641,1412.598,5672.63818,474.840,
4594.15771,1412.598,5672.72949,474.840,
4594.24951,1413.598,5672.82129,474.840,
4594.34082,1412.598,5672.91260,474.840,
4594.43262,1411.598,5673.00439,474.840,
4594.52393,1412.598,5673.09570,474.840,
4594.61523,1411.598,5673.18750,473.840,
4594.70703,1411.598,5673.27881,473.840,
4594.79834,1411.598,5673.37012,473.840,
4594.89014,1410.598,5673.46191,473.840,
4594.98145,1410.598,5673.55322,473.840,
4595.07324,1409.598,5673.64502,473.840,
4595.16455,1409.598,5673.73633,473.840,
4595.25586,1409.598,5673.82813,473.840,
4595.34766,1409.598,5673.91943,473.840,
4595.43896,1409.598,5674.01074,472.840,
4595.53076,1409.598,5674.10254,472.840,
4595.62207,1408.598,5674.19385,472.840,
4595.71387,1408.598,5674.28564,471.840,
4595.80518,1408.598,5674.37695,472.840,
4595.89648,1407.598,5674.46875,471.840,
4595.98828,1408.598,5674.56006,471.840,
4596.07959,1407.598,5674.65137,471.840,
4596.17139,1407.598,5674.74316,470.840,
4596.26270,1406.598,5674.83447,471.840,
4596.35449,1407.598,5674.92627,471.840,
4596.44580,1407.598,5675.01758,470.840,
4596.53711,1406.598,5675.10938,470.840,
4596.62891,1406.598,5675.20068,471.840,
4596.72021,1405.598,5675.29248,470.840,
4596.81201,1405.598,5675.38379,470.840,
4596.90332,1405.598,5675.47510,470.840,
4596.99512,1405.598,5675.56689,469.840,
4597.08643,1404.598,5675.65820,469.840,
4597.17822,1404.598,5675.75000,469.840,
4597.26953,1404.598,5675.84131,469.840,
4597.36084,1404.598,5675.93311,469.840,
4597.45264,1404.598,5676.02441,469.840,
4597.54395,1404.598,5676.11572,468.840,
4597.63574,1403.598,5676.20752,468.840,
4597.72705,1403.598,5676.29883,468.840,
4597.81885,1403.598,5676.39063,468.840,
4597.91016,1403.598,5676.48193,468.840,
4598.00146,1403.598,5676.57373,467.840,
4598.09326,1402.598,5676.66504,467.840,
4598.18457,1402.598,5676.75635,467.840,
4598.27637,1402.598,5676.84814,466.840,
4598.36768,1401.598,5676.93945,465.840,
4598.45947,1401.598,5677.03125,466.840,
4598.55078,1401.598,5677.12256,465.840,
4598.64209,1400.598,5677.21436,465.840,
4598.73389,1400.598,5677.30566,464.840,
4598.82520,1400.598,5677.39746,465.840,
4598.91699,1400.598,5677.48877,464.840,
4599.00830,1400.598,5677.58008,464.840,
4599.10010,1400.598,5677.67188,464.840,
4599.19141,1399.598,5677.76318,464.840,
4599.28320,1399.598,5677.85498,464.840,
4599.37451,1399.598,5677.94629,464.840,
4599.46582,1399.598,5678.03809,464.840,
4599.55762,1398.598,5678.12939,465.840,
4599.64893,1398.598,5678.22070,464.840,
4599.74072,1398.598,5678.31250,464.840,
4599.83203,1397.598,5678.40381,464.840,
4599.92383,1397.598,5678.49561,464.840,
4600.01514,1397.598,5678.58691,464.840,
4600.10645,1397.598,5678.67871,464.840,
4600.19824,1396.598,5678.77002,464.840,
4600.28955,1396.598,5678.86133,464.840,
4600.38135,1397.598,5678.95313,464.840,
4600.47266,1396.598,5679.04443,464.840,
4600.56445,1395.598,5679.13623,464.840,
4600.65576,1396.598,5679.22754,463.840,
4600.74707,1395.598,5679.31934,463.840,
4600.83887,1395.598,5679.41064,463.840,
4600.93018,1395.598,5679.50244,463.840,
4601.02197,1394.598,5679.59375,463.840,
4601.11328,1394.598,5679.68506,462.840,
4601.20508,1394.598,5679.77686,462.840,
4601.29639,1394.598,5679.86816,462.840,
4601.38818,1393.598,5679.95996,462.840,
4601.47949,1394.598,5680.05127,462.840,
4601.57080,1394.598,5680.14307,461.840,
4601.66260,1393.598,5680.23438,461.840,
4601.75391,1393.598,5680.32568,462.840,
4601.84570,1394.598,5680.41748,461.840,
4601.93701,1393.598,5680.50879,461.840,
4602.02881,1393.598,5680.60059,461.840,
4602.12012,1393.598,5680.69189,461.840,
4602.21143,1393.598,5680.78369,460.840,
4602.30322,1392.598,5680.87500,460.840,
4602.39453,1392.598,5680.96631,460.840,
4602.48633,1392.598,5681.05811,461.840,
4602.57764,1391.598,5681.14941,460.840,
4602.66943,1391.598,5681.24121,460.840,
4602.76074,1391.598,5681.33252,460.840,
4602.85205,1390.598,5681.42432,459.840,
4602.94385,1389.598,5681.51563,460.840,
4603.03516,1389.598,5681.60693,460.840,
4603.12695,1389.598,5681.69873,459.840,
4603.21826,1389.598,5681.79004,459.840,
4603.31006,1389.598,5681.88184,459.840,
4603.40137,1389.598,5681.97314,459.840,
4603.49316,1388.598,5682.06494,459.840,
4603.58447,1388.598,5682.15625,459.840,
4603.67578,1387.598,5682.24805,459.840,
4603.76758,1387.598,5682.33936,458.840,
4603.85889,1386.598,5682.43066,459.840,
4603.95068,1385.598,5682.52246,459.840,
4604.04199,1386.598,5682.61377,458.840,
4604.13379,1385.598,5682.70557,458.840,
4604.22510,1385.598,5682.79688,458.840,
4604.31641,1385.598,5682.88867,458.840,
4604.40820,1385.598,5682.97998,457.840,
4604.49951,1385.598,5683.07129,457.840,
4604.59131,1384.598,5683.16309,457.840,
4604.68262,1384.598,5683.25439,457.840,
4604.77441,1385.598,5683.34619,456.840,
4604.86572,1384.598,5683.43750,457.840,
4604.95703,1384.598,5683.52930,456.840,
4605.04883,1383.598,5683.62061,456.840,
4605.14014,1383.598,5683.71191,456.840,
4605.23193,1383.598,5683.80371,456.840,
4605.32324,1382.598,5683.89502,456.840,
4605.41504,1383.598,5683.98682,455.840,
4605.50635,1382.598,5684.07813,455.840,
4605.59814,1382.598,5684.16992,455.840,
4605.68945,1382.598,5684.26123,455.840,
4605.78076,1382.598,5684.35303,454.840,
4605.87256,1382.598,5684.44434,454.840,
4605.96387,1381.598,5684.53564,454.840,
4606.05566,1381.598,5684.62744,454.840,
4606.14697,1381.598,5684.71875,455.840,
4606.23877,1381.598,5684.81055,454.840,
4606.33008,1380.598,5684.90186,454.840,
4606.42139,1380.598,5684.99365,454.840,
4606.51318,1380.598,5685.08496,454.840,
4606.60449,1379.598,5685.17627,454.840,
4606.69629,1379.598,5685.26807,454.840,
4606.78760,1379.598,5685.35938,453.840,
4606.87939,1379.598,5685.45117,454.840,
4606.97070,1379.598,5685.54248,453.840,
4607.06201,1378.598,5685.63428,452.840,
4607.15381,1378.598,5685.72559,452.840,
4607.24512,1378.598,5685.81689,452.840,
4607.33691,1377.598,5685.90869,452.840,
4607.42822,1377.598,5686.00000,452.840,
4607.52002,1377.598,5686.09180,452.840,
4607.61133,1377.598,5686.18311,452.840,
4607.70264,1377.598,5686.27490,451.840,
4607.79443,1376.598,5686.36621,451.840,
4607.88574,1376.598,5686.45801,451.840,
4607.97754,1376.598,5686.54932,451.840,
4608.06885,1376.598,5686.64063,451.840,
4608.16064,1375.598,5686.73242,451.840,
4608.25195,1375.598,5686.82373,451.840,
4608.34375,1374.598,5686.91553,451.840,
4608.43506,1374.598,5687.00684,450.840,
4608.52637,1374.598,5687.09863,451.840,
4608.61816,1374.598,5687.18994,450.840,
4608.70947,1373.598,5687.28125,450.840,
4608.80127,1374.598,5687.37305,450.840,
4608.89258,1373.598,5687.46436,449.840,
4608.98438,1373.598,5687.55615,449.840,
4609.07568,1373.598,5687.64746,449.840,
4609.16699,1373.598,5687.73926,450.840,
4609.25879,1372.598,5687.83057,449.840,
4609.35010,1372.598,5687.92188,449.840,
4609.44189,1372.598,5688.01367,449.840,
4609.53320,1371.598,5688.10498,449.840,
4609.62500,1372.598,5688.19678,449.840,
4609.71631,1371.598,5688.28809,448.840,
4609.80762,1371.598,5688.37988,449.840,
4609.89941,1370.598,5688.47119,449.840,
4609.99072,1371.598,5688.56299,448.840,
4610.08252,1370.598,5688.65430,448.840,
4610.17383,1370.598,5688.74561,448.840,
4610.26563,1370.598,5688.83740,447.840,
4610.35693,1370.598,5688.92871,448.840,
4610.44873,1369.598,5689.02051,448.840,
4610.54004,1369.598,5689.11182,447.840,
4610.63135,1369.598,5689.20361,447.840,
4610.72314,1368.598,5689.29492,447.840,
4610.81445,1368.598,5689.38623,447.840,
4610.90625,1368.598,5689.47803,447.840,
4610.99756,1368.598,5689.56934,447.840,
4611.08936,1367.598,5689.66113,446.840,
4611.18066,1368.598,5689.75244,447.840,
4611.27197,1367.598,5689.84424,447.840,
4611.36377,1367.598,5689.93555,447.840,
4611.45508,1366.598,5690.02686,446.840,
4611.54688,1366.598,5690.11865,447.840,
4611.63818,1366.598,5690.20996,446.840,
4611.72998,1366.598,5690.30176,446.840,
4611.82129,1366.598,5690.39307,446.840,
4611.91260,1365.598,5690.48486,446.840,
4612.00439,1365.598,5690.57617,446.840,
4612.09570,1366.598,5690.66797,445.840,
4612.18750,1364.598,5690.75928,445.840,
4612.27881,1364.598,5690.85059,445.840,
4612.37061,1364.598,5690.94238,444.840,
4612.46191,1364.598,5691.03369,444.840,
4612.55371,1363.598,5691.12549,444.840,
4612.64502,1364.598,5691.21680,444.840,
4612.73633,1363.598,5691.30859,445.840,
4612.82813,1363.598,5691.39990,444.840,
4612.91943,1363.598,5691.49121,444.840,
4613.01123,1363.598,5691.58301,444.840,
4613.10254,1362.598,5691.67432,443.840,
4613.19434,1362.598,5691.76611,443.840,
4613.28564,1362.598,5691.85742,444.840,
4613.37695,1362.598,5691.94922,443.840,
4613.46875,1362.598,5692.04053,443.840,
4613.56006,1362.598,5692.13184,443.840,
4613.65186,1361.598,5692.22363,443.840,
4613.74316,1361.598,5692.31494,443.840,
4613.83496,1360.598,5692.40674,442.840,
4613.92627,1361.598,5692.49805,442.840,
4614.01758,1360.598,5692.58984,442.840,
4614.10938,1360.598,5692.68115,442.840,
4614.20068,1360.598,5692.77246,442.840,
4614.29248,1360.598,5692.86426,442.840,
4614.38379,1359.598,5692.95557,441.840,
4614.47559,1359.598,5693.04736,441.840,
4614.56689,1359.598,5693.13867,441.840,
4614.65869,1358.598,5693.23047,441.840,
4614.75000,1358.598,5693.32178,440.840,
4614.84131,1358.598,5693.41357,440.840,
4614.93311,1358.598,5693.50488,440.840,
4615.02441,1358.598,5693.59619,440.840,
4615.11621,1358.598,5693.68799,439.840,
4615.20752,1357.598,5693.77930,439.840,
4615.29932,1357.598,5693.87109,440.840,
4615.39063,1357.598,5693.96240,439.840,
4615.48193,1356.598,5694.05420,439.840,
4615.57373,1356.598,5694.14551,439.840,
4615.66504,1356.598,5694.23682,439.840,
4615.75684,1356.598,5694.32861,439.840,
4615.84814,1355.598,5694.41992,439.840,
4615.93994,1355.598,5694.51172,438.840,
4616.03125,1355.598,5694.60303,439.840,
4616.12256,1355.598,5694.69482,439.840,
4616.21436,1354.598,5694.78613,438.840,
4616.30566,1354.598,5694.87744,438.840,
4616.39746,1354.598,5694.96924,438.840,
4616.48877,1354.598,5695.06055,438.840,
4616.58057,1354.598,5695.15234,437.840,
4616.67188,1353.598,5695.24365,437.840,
4616.76367,1353.598,5695.33545,437.840,
4616.85498,1353.598,5695.42676,437.840,
4616.94629,1353.598,5695.51855,437.840,
4617.03809,1352.598,5695.60986,437.840,
4617.12939,1353.598,5695.70117,437.840,
4617.22119,1352.598,5695.79297,437.840,
4617.31250,1352.598,5695.88428,437.840,
4617.40430,1351.598,5695.97607,437.840,
4617.49561,1351.598,5696.06738,437.840,
4617.58691,1351.598,5696.15918,437.840,
4617.67871,1350.598,5696.25049,437.840,
4617.77002,1351.598,5696.34180,437.840,
4617.86182,1350.598,5696.43359,436.840,
4617.95313,1351.598,5696.52490,437.840,
4618.04492,1349.598,5696.61670,437.840,
4618.13623,1349.598,5696.70801,437.840,
4618.22754,1349.598,5696.79980,436.840,
4618.31934,1349.598,5696.89111,436.840,
4618.41064,1349.598,5696.98242,436.840,
4618.50244,1349.598,5697.07422,437.840,
4618.59375,1348.598,5697.16553,437.840,
4618.68555,1348.598,5697.25732,436.840,
4618.77686,1348.598,5697.34863,436.840,
4618.86865,1348.598,5697.44043,436.840,
4618.95996,1347.598,5697.53174,435.840,
4619.05127,1347.598,5697.62354,435.840,
4619.14307,1347.598,5697.71484,435.840,
4619.23438,1346.598,5697.80615,435.840,
4619.32617,1346.598,5697.89795,434.840,
4619.41748,1347.598,5697.98926,433.840,
4619.50928,1345.598,5698.08105,433.840,
4619.60059,1346.598,5698.17236,433.840,
4619.69189,1346.598,5698.26416,433.840,
4619.78369,1345.598,5698.35547,433.840,
4619.87500,1345.598,5698.44678,433.840,
4619.96680,1345.598,5698.53857,433.840,
4620.05811,1344.598,5698.62988,433.840,
4620.14990,1344.598,5698.72168,433.840,
4620.24121,1344.598,5698.81299,431.840,
4620.33252,1344.598,5698.90479,431.840,
4620.42432,1343.598,5698.99609,431.840,
4620.51563,1343.598,5699.08740,430.840,
4620.60742,1343.598,5699.17920,430.840,
4620.69873,1343.598,5699.27051,431.840,
4620.79053,1343.598,5699.36230,430.840,
4620.88184,1343.598,5699.45361,430.840,
4620.97314,1342.598,5699.54541,430.840,
4621.06494,1342.598,5699.63672,430.840,
4621.15625,1342.598,5699.72852,430.840,
4621.24805,1342.598,5699.81982,430.840,
4621.33936,1341.598,5699.91113,429.840,
4621.43115,1342.598,5700.00293,430.840,
4621.52246,1340.598,5700.09424,430.840,
4621.61426,1340.598,5700.18604,430.840,
4621.70557,1340.598,5700.27734,429.840,
4621.79688,1340.598,5700.36914,429.840,
4621.88867,1339.598,5700.46045,430.840,
4621.97998,1339.598,5700.55176,430.840,
4622.07178,1338.598,5700.64355,429.840,
4622.16309,1337.598,5700.73486,429.840,
4622.25488,1337.598,5700.82666,429.840,
4622.34619,1338.598,5700.91797,429.840,
4622.43750,1337.598,5701.00977,428.840,
4622.52930,1336.598,5701.10107,428.840,
4622.62061,1336.598,5701.19238,428.840,
4622.71240,1336.598,5701.28418,428.840,
4622.80371,1335.598,5701.37549,428.840,
4622.89551,1335.598,5701.46729,428.840,
4622.98682,1335.598,5701.55859,428.840,
4623.07813,1335.598,5701.65039,428.840,
4623.16992,1334.598,5701.74170,427.840,
4623.26123,1335.598,5701.83350,427.840,
4623.35303,1335.598,5701.92480,427.840,
4623.44434,1334.598,5702.01611,427.840,
4623.53613,1335.598,5702.10791,426.840,
4623.62744,1334.598,5702.19922,426.840,
4623.71924,1334.598,5702.29102,427.840,
4623.81055,1335.598,5702.38232,426.840,
4623.90186,1334.598,5702.47412,426.840,
4623.99365,1334.598,5702.56543,426.840,
4624.08496,1335.598,5702.65674,426.840,
4624.17676,1335.598,5702.74854,426.840,
4624.26807,1335.598,5702.83984,426.840,
4624.35986,1335.598,5702.93164,426.840,
4624.45117,1335.598,5703.02295,426.840,
4624.54248,1335.598,5703.11475,425.840,
4624.63428,1335.598,5703.20605,425.840,
4624.72559,1335.598,5703.29736,425.840,
4624.81738,1335.598,5703.38916,425.840,
4624.90869,1334.598,5703.48047,425.840,
4625.00049,1334.598,5703.57227,425.840,
4625.09180,1334.598,5703.66357,424.840,
4625.18311,1333.598,5703.75537,424.840,
4625.27490,1334.598,5703.84668,424.840,
4625.36621,1333.598,5703.93848,424.840,
4625.45801,1333.598,5704.02979,424.840,
4625.54932,1332.598,5704.12109,424.840,
4625.64111,1332.598,5704.21289,424.840,
4625.73242,1331.598,5704.30420,423.840,
4625.82422,1331.598,5704.39600,423.840,
4625.91553,1330.598,5704.48730,424.840,
4626.00684,1330.598,5704.57910,423.840,
4626.09863,1330.598,5704.67041,423.840,
4626.18994,1329.598,5704.76172,423.840,
4626.28174,1329.598,5704.85352,423.840,
4626.37305,1329.598,5704.94482,422.840,
4626.46484,1329.598,5705.03662,422.840,
4626.55615,1328.598,5705.12793,422.840,
4626.64746,1328.598,5705.21973,422.840,
4626.73926,1328.598,5705.31104,422.840,
4626.83057,1328.598,5705.40234,421.840,
4626.92236,1328.598,5705.49414,421.840,
4627.01367,1328.598,5705.58545,421.840,
4627.10547,1327.598,5705.67725,421.840,
4627.19678,1327.598,5705.76855,421.840,
4627.28809,1326.598,5705.86035,421.840,
4627.37988,1326.598,5705.95166,421.840,
4627.47119,1326.598,5706.04297,421.840,
4627.56299,1326.598,5706.13477,421.840,
4627.65430,1325.598,5706.22607,420.840,
4627.74609,1325.598,5706.31787,421.840,
4627.83740,1325.598,5706.40918,420.840,
4627.92920,1325.598,5706.50098,420.840,
4628.02051,1325.598,5706.59229,420.840,
4628.11182,1324.598,5706.68408,420.840,
4628.20361,1325.598,5706.77539,420.840,
4628.29492,1324.598,5706.86670,420.840,
4628.38672,1324.598,5706.95850,420.840,
4628.47803,1324.598,5707.04980,419.840,
4628.56982,1323.598,5707.14160,420.840,
4628.66113,1323.598,5707.23291,420.840,
4628.75244,1323.598,5707.32471,419.840,
4628.84424,1323.598,5707.41602,419.840,
4628.93555,1323.598,5707.50732,419.840,
4629.02734,1322.598,5707.59912,419.840,
4629.11865,1322.598,5707.69043,419.840,
4629.21045,1322.598,5707.78223,419.840,
4629.30176,1321.598,5707.87354,418.840,
4629.39307,1322.598,5707.96533,418.840,
4629.48486,1321.598,5708.05664,418.840,
4629.57617,1321.598,5708.14795,418.840,
4629.66797,1321.598,5708.23975,418.840,
4629.75928,1320.598,5708.33105,417.840,
4629.85107,1320.598,5708.42285,417.840,
4629.94238,1320.598,5708.51416,417.840,
4630.03418,1320.598,5708.60596,417.840,
4630.12549,1319.598,5708.69727,417.840,
4630.21680,1319.598,5708.78906,417.840,
4630.30859,1318.598,5708.88037,417.840,
4630.39990,1319.598,5708.97168,417.840,
4630.49170,1319.598,5709.06348,417.840,
4630.58301,1318.598,5709.15479,416.840,
4630.67480,1318.598,5709.24658,416.840,
4630.76611,1318.598,5709.33789,416.840,
4630.85742,1318.598,5709.42969,416.840,
4630.94922,1317.598,5709.52100,415.840,
4631.04053,1317.598,5709.61230,416.840,
4631.13232,1317.598,5709.70410,416.840,
4631.22363,1316.598,5709.79541,415.840,
4631.31543,1316.598,5709.88721,415.840,
4631.40674,1316.598,5709.97852,415.840,
4631.49805,1316.598,5710.07031,415.840,
4631.58984,1315.598,5710.16162,414.840,
4631.68115,1315.598,5710.25293,414.840,
4631.77295,1315.598,5710.34473,415.840,
4631.86426,1315.598,5710.43604,414.840,
4631.95605,1315.598,5710.52783,414.840,
4632.04736,1314.598,5710.61914,414.840,
4632.13916,1314.598,5710.71094,414.840,
4632.23047,1314.598,5710.80225,414.840,
4632.32178,1314.598,5710.89404,413.840,
4632.41357,1313.598,5710.98535,413.840,
4632.50488,1313.598,5711.07666,413.840,
4632.59668,1313.598,5711.16846,413.840,
4632.68799,1313.598,5711.25977,413.840,
4632.77979,1312.598,5711.35156,413.840,
4632.87109,1312.598,5711.44287,413.840,
4632.96240,1313.598,5711.53467,412.840,
4633.05420,1312.598,5711.62598,413.840,
4633.14551,1312.598,5711.71729,412.840,
4633.23730,1312.598,5711.80908,413.840,
4633.32861,1311.598,5711.90039,412.840,
4633.42041,1311.598,5711.99219,412.840,
4633.51172,1311.598,5712.08350,412.840,
4633.60303,1310.598,5712.17529,411.840,
4633.69482,1310.598,5712.26660,412.840,
4633.78613,1310.598,5712.35791,411.840,
4633.87793,1310.598,5712.44971,411.840,
4633.96924,1310.598,5712.54102,411.840,
4634.06104,1310.598,5712.63281,410.840,
4634.15234,1310.598,5712.72412,411.840,
4634.24365,1309.598,5712.81592,410.840,
4634.33545,1309.598,5712.90723,411.840,
4634.42676,1309.598,5712.99902,410.840,
4634.51855,1308.598,5713.09033,411.840,
4634.60986,1308.598,5713.18164,410.840,
4634.70166,1308.598,5713.27344,410.840,
4634.79297,1308.598,5713.36475,410.840,
4634.88477,1308.598,5713.45654,410.840,
4634.97607,1307.598,5713.54785,410.840,
4635.06738,1307.598,5713.63965,410.840,
4635.15918,1307.598,5713.73096,410.840,
4635.25049,1306.598,5713.82227,409.840,
4635.34229,1306.598,5713.91406,409.840,
4635.43359,1306.598,5714.00537,409.840,
4635.52539,1306.598,5714.09717,408.840,
4635.61670,1305.598,5714.18848,409.840,
4635.70801,1305.598,5714.28027,409.840,
4635.79980,1305.598,5714.37158,408.840,
4635.89111,1305.598,5714.46289,407.840,
4635.98291,1305.598,5714.55469,408.840,
4636.07422,1304.598,5714.64600,408.840,
4636.16602,1304.598,5714.73779,408.840,
4636.25732,1305.598,5714.82910,407.840,
4636.34863,1304.598,5714.92090,407.840,
4636.44043,1303.598,5715.01221,407.840,
4636.53174,1304.598,5715.10400,407.840,
4636.62354,1303.598,5715.19531,407.840,
4636.71484,1303.598,5715.28662,407.840,
4636.80664,1303.598,5715.37842,407.840,
4636.89795,1303.598,5715.46973,406.840,
4636.98975,1303.598,5715.56152,405.840,
4637.08105,1302.598,5715.65283,405.840,
4637.17236,1302.598,5715.74463,404.840,
4637.26416,1302.598,5715.83594,404.840,
4637.35547,1302.598,5715.92725,404.840,
4637.44727,1301.598,5716.01904,403.840,
4637.53857,1301.598,5716.11035,404.840,
4637.63037,1301.598,5716.20215,404.840,
4637.72168,1301.598,5716.29346,403.840,
4637.81299,1300.598,5716.38525,403.840,
4637.90479,1300.598,5716.47656,403.840,
4637.99609,1299.598,5716.56787,404.840,
4638.08789,1299.598,5716.65967,403.840,
4638.17920,1299.598,5716.75098,404.840,
4638.27100,1299.598,5716.84277,404.840,
4638.36230,1299.598,5716.93408,404.840,
4638.45361,1299.598,5717.02588,404.840,
4638.54541,1299.598,5717.11719,404.840,
4638.63672,1298.598,5717.20898,404.840,
4638.72852,1298.598,5717.30029,404.840,
4638.81982,1298.598,5717.39160,404.840,
4638.91162,1298.598,5717.48340,403.840,
4639.00293,1298.598,5717.57471,404.840,
4639.09473,1297.598,5717.66650,404.840,
4639.18604,1297.598,5717.75781,402.840,
4639.27734,1297.598,5717.84961,402.840,
4639.36914,1296.598,5717.94092,401.840,
4639.46045,1296.598,5718.03223,400.840,
4639.55225,1296.598,5718.12402,399.840,
4639.64355,1296.598,5718.21533,399.840,
4639.73535,1296.598,5718.30713,398.840,
4639.82666,1295.598,5718.39844,398.840,
4639.91797,1296.598,5718.49023,398.840,
4640.00977,1295.598,5718.58154,398.840,
4640.10107,1295.598,5718.67285,398.840,
4640.19287,1294.598,5718.76465,398.840,
4640.28418,1295.598,5718.85596,398.840,
4640.37598,1294.598,5718.94775,398.840,
4640.46729,1294.598,5719.03906,398.840,
4640.55859,1294.598,5719.13086,399.840,
4640.65039,1294.598,5719.22217,398.840,
4640.74170,1293.598,5719.31348,399.840,
4640.83350,1293.598,5719.40527,399.840,
4640.92480,1293.598,5719.49658,399.840,
4641.01660,1292.598,5719.58838,398.840,
4641.10791,1292.598,5719.67969,399.840,
4641.19971,1292.598,5719.77148,399.840,
4641.29102,1291.598,5719.86279,399.840,
4641.38232,1292.598,5719.95459,399.840,
4641.47412,1291.598,5720.04590,399.840,
4641.56543,1291.598,5720.13721,399.840,
4641.65723,1290.598,5720.22900,399.840,
4641.74854,1291.598,5720.32031,399.840,
4641.84033,1290.598,5720.41211,399.840,
4641.93164,1289.598,5720.50342,399.840,
4642.02295,1290.598,5720.59521,400.840,
4642.11475,1290.598,5720.68652,399.840,
4642.20605,1289.598,5720.77783,399.840,
4642.29785,1289.598,5720.86963,398.840,
4642.38916,1289.598,5720.96094,399.840,
4642.48096,1288.598,5721.05273,399.840,
4642.57227,1289.598,5721.14404,398.840,
4642.66357,1288.598,5721.23584,398.840,
4642.75537,1288.598,5721.32715,398.840,
4642.84668,1288.598,5721.41846,397.840,
4642.93848,1287.598,5721.51025,397.840,
4643.02979,1287.598,5721.60156,397.840,
4643.12158,1287.598,5721.69336,397.840,
4643.21289,1287.598,5721.78467,397.840,
4643.30469,1286.598,5721.87646,397.840,
4643.39600,1286.598,5721.96777,397.840,
4643.48730,1286.598,5722.05957,397.840,
4643.57910,1286.598,5722.15088,397.840,
4643.67041,1286.598,5722.24219,396.840,
4643.76221,1285.598,5722.33398,396.840,
4643.85352,1285.598,5722.42529,396.840,
4643.94531,1285.598,5722.51709,396.840,
4644.03662,1284.598,5722.60840,396.840,
4644.12793,1285.598,5722.70020,395.840,
4644.21973,1284.598,5722.79150,396.840,
4644.31104,1285.598,5722.88281,395.840,
4644.40283,1284.598,5722.97461,395.840,
4644.49414,1284.598,5723.06592,395.840,
4644.58594,1285.598,5723.15771,395.840,
4644.67725,1285.598,5723.24902,395.840,
4644.76855,1285.598,5723.34082,394.840,
4644.86035,1284.598,5723.43213,395.840,
4644.95166,1284.598,5723.52344,395.840,
4645.04346,1284.598,5723.61523,394.840,
4645.13477,1283.598,5723.70654,395.840,
4645.22656,1284.598,5723.79834,394.840,
4645.31787,1282.598,5723.88965,394.840,
4645.40918,1283.598,5723.98145,394.840,
4645.50098,1282.598,5724.07275,394.840,
4645.59229,1282.598,5724.16455,394.840,
4645.68408,1282.598,5724.25586,393.840,
4645.77539,1281.598,5724.34717,393.840,
4645.86719,1281.598,5724.43896,393.840,
4645.95850,1281.598,5724.53027,393.840,
4646.05029,1280.598,5724.62207,393.840,
4646.14160,1280.598,5724.71338,393.840,
4646.23291,1280.598,5724.80518,392.840,
4646.32471,1279.598,5724.89648,392.840,
4646.41602,1279.598,5724.98779,393.840,
4646.50781,1278.598,5725.07959,393.840,
4646.59912,1278.598,5725.17090,392.840,
4646.69092,1278.598,5725.26270,392.840,
4646.78223,1278.598,5725.35400,392.840,
4646.87354,1278.598,5725.44580,392.840,
4646.96533,1277.598,5725.53711,392.840,
4647.05664,1277.598,5725.62842,392.840,
4647.14844,1277.598,5725.72021,391.840,
4647.23975,1277.598,5725.81152,391.840,
4647.33154,1277.598,5725.90332,392.840,
4647.42285,1277.598,5725.99463,391.840,
4647.51416,1276.598,5726.08643,391.840,
4647.60596,1276.598,5726.17773,391.840,
4647.69727,1275.598,5726.26953,391.840,
4647.78906,1275.598,5726.36084,390.840,
4647.88037,1275.598,5726.45215,391.840,
4647.97217,1275.598,5726.54395,390.840,
4648.06348,1274.598,5726.63525,391.840,
4648.15527,1275.598,5726.72705,390.840,
4648.24658,1274.598,5726.81836,390.840,
4648.33789,1274.598,5726.91016,390.840,
4648.42969,1274.598,5727.00146,390.840,
4648.52100,1273.598,5727.09277,390.840,
4648.61279,1273.598,5727.18457,390.840,
4648.70410,1274.598,5727.27588,389.840,
4648.79590,1273.598,5727.36768,390.840,
4648.88721,1273.598,5727.45898,389.840,
4648.97852,1273.598,5727.55078,389.840,
4649.07031,1273.598,5727.64209,389.840,
4649.16162,1272.598,5727.73340,389.840,
4649.25342,1272.598,5727.82520,389.840,
4649.34473,1272.598,5727.91650,389.840,
4649.43652,1271.598,5728.00830,388.840,
4649.52783,1271.598,5728.09961,388.840,
4649.61914,1271.598,5728.19141,388.840,
4649.71094,1271.598,5728.28271,389.840,
4649.80225,1271.598,5728.37451,388.840,
4649.89404,1270.598,5728.46582,387.840,
4649.98535,1270.598,5728.55713,387.840,
4650.07715,1270.598,5728.64893,388.840,
4650.16846,1270.598,5728.74023,387.840,
4650.26025,1269.598,5728.83203,387.840,
4650.35156,1269.598,5728.92334,387.840,
4650.44287,1269.598,5729.01514,387.840,
4650.53467,1269.598,5729.10645,387.840,
4650.62598,1269.598,5729.19775,387.840,
4650.71777,1269.598,5729.28955,386.840,
4650.80908,1268.598,5729.38086,386.840,
4650.90088,1267.598,5729.47266,386.840,
4650.99219,1267.598,5729.56396,386.840,
4651.08350,1267.598,5729.65576,386.840,
4651.17529,1267.598,5729.74707,386.840,
4651.26660,1266.598,5729.83838,386.840,
4651.35840,1267.598,5729.93018,386.840,
4651.44971,1266.598,5730.02148,385.840,
4651.54150,1266.598,5730.11328,385.840,
4651.63281,1266.598,5730.20459,385.840,
4651.72412,1266.598,5730.29639,385.840,
4651.81592,1265.598,5730.38770,385.840,
4651.90723,1265.598,5730.47900,385.840,
4651.99902,1265.598,5730.57080,384.840,
4652.09033,1265.598,5730.66211,385.840,
4652.18213,1264.598,5730.75391,384.840,
4652.27344,1265.598,5730.84521,385.840,
4652.36523,1264.598,5730.93701,383.840,
4652.45654,1264.598,5731.02832,384.840,
4652.54785,1264.598,5731.12012,384.840,
4652.63965,1263.598,5731.21143,383.840,
4652.73096,1263.598,5731.30273,383.840,
4652.82275,1263.598,5731.39453,384.840,
4652.91406,1263.598,5731.48584,383.840,
4653.00586,1262.598,5731.57764,383.840,
4653.09717,1262.598,5731.66895,383.840,
4653.18848,1262.598,5731.76074,383.840,
4653.28027,1262.598,5731.85205,382.840,
4653.37158,1261.598,5731.94336,382.840,
4653.46338,1261.598,5732.03516,383.840,
4653.55469,1261.598,5732.12646,382.840,
4653.64648,1261.598,5732.21826,382.840,
4653.73779,1261.598,5732.30957,383.840,
4653.82910,1261.598,5732.40137,382.840,
4653.92090,1260.598,5732.49268,382.840,
4654.01221,1259.598,5732.58398,382.840,
4654.10400,1260.598,5732.67578,381.840,
4654.19531,1259.598,5732.76709,381.840,
4654.28711,1259.598,5732.85889,381.840,
4654.37842,1259.598,5732.95020,382.840,
4654.47021,1259.598,5733.04199,381.840,
4654.56152,1259.598,5733.13330,381.840,
4654.65283,1258.598,5733.22510,381.840,
4654.74463,1258.598,5733.31641,380.840,
4654.83594,1258.598,5733.40771,380.840,
4654.92773,1257.598,5733.49951,381.840,
4655.01904,1257.598,5733.59082,380.840,
4655.11084,1257.598,5733.68262,380.840,
4655.20215,1257.598,5733.77393,381.840,
4655.29346,1257.598,5733.86572,380.840,
4655.38525,1256.598,5733.95703,380.840,
4655.47656,1256.598,5734.04834,380.840,
4655.56836,1256.598,5734.14014,380.840,
4655.65967,1256.598,5734.23145,380.840,
4655.75146,1256.598,5734.32324,379.840,
4655.84277,1255.598,5734.41455,379.840,
4655.93408,1255.598,5734.50635,379.840,
4656.02588,1255.598,5734.59766,379.840,
4656.11719,1254.598,5734.68896,378.840,
4656.20898,1254.598,5734.78076,378.840,
4656.30029,1254.598,5734.87207,377.840,
4656.39209,1254.598,5734.96387,376.840,
4656.48340,1254.598,5735.05518,376.840,
4656.57520,1253.598,5735.14697,375.840,
4656.66650,1253.598,5735.23828,375.840,
4656.75781,1253.598,5735.33008,375.840,
4656.84961,1253.598,5735.42139,375.840,
4656.94092,1253.598,5735.51270,375.840,
4657.03271,1252.598,5735.60449,375.840,
4657.12402,1253.598,5735.69580,375.840,
4657.21582,1252.598,5735.78760,375.840,
4657.30713,1252.598,5735.87891,376.840,
4657.39844,1252.598,5735.97070,376.840,
4657.49023,1252.598,5736.06201,376.840,
4657.58154,1251.598,5736.15332,375.840,
4657.67334,1251.598,5736.24512,376.840,
4657.76465,1251.598,5736.33643,376.840,
4657.85645,1251.598,5736.42822,377.840,
4657.94775,1251.598,5736.51953,376.840,
4658.03906,1251.598,5736.61133,376.840,
4658.13086,1250.598,5736.70264,377.840,
4658.22217,1250.598,5736.79395,376.840,
4658.31396,1250.598,5736.88574,376.840,
4658.40527,1249.598,5736.97705,375.840,
4658.49707,1249.598,5737.06885,375.840,
4658.58838,1249.598,5737.16016,374.840,
4658.67969,1249.598,5737.25195,374.840,
4658.77148,1248.598,5737.34326,373.840,
4658.86279,1248.598,5737.43506,372.840,
4658.95459,1249.598,5737.52637,372.840,
4659.04590,1248.598,5737.61768,371.840,
4659.13770,1248.598,5737.70947,371.840,
4659.22900,1248.598,5737.80078,372.840,
4659.32080,1247.598,5737.89258,372.840,
4659.41211,1247.598,5737.98389,371.840,
4659.50342,1247.598,5738.07568,372.840,
4659.59521,1246.598,5738.16699,373.840,
4659.68652,1246.598,5738.25830,372.840,
4659.77832,1246.598,5738.35010,372.840,
4659.86963,1246.598,5738.44141,372.840,
4659.96143,1246.598,5738.53320,373.840,
4660.05273,1245.598,5738.62451,372.840,
4660.14404,1246.598,5738.71631,372.840,
4660.23584,1245.598,5738.80762,373.840,
4660.32715,1245.598,5738.89893,372.840,
4660.41895,1245.598,5738.99072,372.840,
4660.51025,1244.598,5739.08203,372.840,
4660.60205,1244.598,5739.17383,372.840,
4660.69336,1244.598,5739.26514,372.840,
4660.78467,1244.598,5739.35693,372.840,
4660.87646,1243.598,5739.44824,372.840,
4660.96777,1244.598,5739.54004,372.840,
4661.05957,1243.598,5739.63135,372.840,
4661.15088,1243.598,5739.72266,372.840,
4661.24268,1242.598,5739.81445,372.840,
4661.33398,1242.598,5739.90576,372.840,
4661.42578,1242.598,5739.99756,372.840,
4661.51709,1241.598,5740.08887,372.840,
4661.60840,1241.598,5740.18066,371.840,
4661.70020,1240.598,5740.27197,372.840,
4661.79150,1239.598,5740.36328,371.840,
4661.88330,1239.598,5740.45508,371.840,
4661.97461,1238.598,5740.54639,371.840,
4662.06641,1238.598,5740.63818,371.840,
4662.15771,1237.598,5740.72949,371.840,
4662.24902,1237.598,5740.82129,370.840,
4662.34082,1237.598,5740.91260,370.840,
4662.43213,1237.598,5741.00391,370.840,
4662.52393,1237.598,5741.09570,370.840,
4662.61523,1237.598,5741.18701,370.840,
4662.70703,1237.598,5741.27881,370.840,
4662.79834,1237.598,5741.37012,370.840,
4662.88965,1237.598,5741.46191,370.840,
4662.98145,1237.598,5741.55322,370.840,
4663.07275,1237.598,5741.64502,369.840,
4663.16455,1238.598,5741.73633,369.840,
4663.25586,1237.598,5741.82764,369.840,
4663.34766,1238.598,5741.91943,369.840,
4663.43896,1237.598,5742.01074,369.840,
4663.53076,1237.598,5742.10254,369.840,
4663.62207,1237.598,5742.19385,368.840,
4663.71338,1237.598,5742.28564,368.840,
4663.80518,1236.598,5742.37695,369.840,
4663.89648,1236.598,5742.46826,369.840,
4663.98828,1235.598,5742.56006,369.840,
4664.07959,1235.598,5742.65137,368.840,
4664.17139,1234.598,5742.74316,368.840,
4664.26270,1234.598,5742.83447,368.840,
4664.35400,1234.598,5742.92627,368.840,
4664.44580,1233.598,5743.01758,368.840,
4664.53711,1233.598,5743.10889,367.840,
4664.62891,1234.598,5743.20068,367.840,
4664.72021,1234.598,5743.29199,368.840,
4664.81201,1233.598,5743.38379,367.840,
4664.90332,1233.598,5743.47510,367.840,
4664.99463,1233.598,5743.56689,367.840,
4665.08643,1233.598,5743.65820,367.840,
4665.17773,1233.598,5743.74951,366.840,
4665.26953,1233.598,5743.84131,366.840,
4665.36084,1233.598,5743.93262,366.840,
4665.45264,1232.598,5744.02441,367.840,
4665.54395,1233.598,5744.11572,366.840,
4665.63574,1232.598,5744.20752,366.840,
4665.72705,1232.598,5744.29883,365.840,
4665.81836,1232.598,5744.39063,365.840,
4665.91016,1232.598,5744.48193,366.840,
4666.00146,1231.598,5744.57324,366.840,
4666.09326,1231.598,5744.66504,366.840,
4666.18457,1231.598,5744.75635,365.840,
4666.27637,1231.598,5744.84814,365.840,
4666.36768,1231.598,5744.93945,365.840,
4666.45898,1230.598,5745.03125,365.840,
4666.55078,1230.598,5745.12256,365.840,
4666.64209,1229.598,5745.21387,365.840,
4666.73389,1229.598,5745.30566,364.840,
4666.82520,1230.598,5745.39697,364.840,
4666.91699,1230.598,5745.48877,365.840,
4667.00830,1229.598,5745.58008,364.840,
4667.09961,1229.598,5745.67188,364.840,
4667.19141,1229.598,5745.76318,364.840,
4667.28271,1229.598,5745.85449,364.840,
4667.37451,1228.598,5745.94629,364.840,
4667.46582,1228.598,5746.03760,364.840,
4667.55762,1227.598,5746.12939,364.840,
4667.64893,1228.598,5746.22070,363.840,
4667.74072,1228.598,5746.31250,363.840,
4667.83203,1227.598,5746.40381,364.840,
4667.92334,1227.598,5746.49561,363.840,
4668.01514,1227.598,5746.58691,363.840,
4668.10645,1226.598,5746.67822,362.840,
4668.19824,1227.598,5746.77002,363.840,
4668.28955,1226.598,5746.86133,362.840,
4668.38135,1226.598,5746.95313,363.840,
4668.47266,1226.598,5747.04443,363.840,
4668.56396,1226.598,5747.13623,362.840,
4668.65576,1226.598,5747.22754,362.840,
4668.74707,1226.598,5747.31885,362.840,
4668.83887,1225.598,5747.41064,362.840,
4668.93018,1224.598,5747.50195,362.840,
4669.02197,1224.598,5747.59375,362.840,
4669.11328,1224.598,5747.68506,362.840,
4669.20459,1225.598,5747.77686,361.840,
4669.29639,1224.598,5747.86816,361.840,
4669.38770,1224.598,5747.95947,361.840,
4669.47949,1223.598,5748.05127,361.840,
4669.57080,1223.598,5748.14258,361.840,
4669.66260,1223.598,5748.23438,361.840,
4669.75391,1223.598,5748.32568,360.840,
4669.84570,1223.598,5748.41748,360.840,
4669.93701,1222.598,5748.50879,360.840,
4670.02832,1222.598,5748.60059,360.840,
4670.12012,1221.598,5748.69189,360.840,
4670.21143,1221.598,5748.78320,360.840,
4670.30322,1222.598,5748.87500,360.840,
4670.39453,1221.598,5748.96631,360.840,
4670.48633,1221.598,5749.05811,359.840,
4670.57764,1221.598,5749.14941,360.840,
4670.66895,1221.598,5749.24121,359.840,
4670.76074,1220.598,5749.33252,360.840,
4670.85205,1220.598,5749.42383,359.840,
4670.94385,1220.598,5749.51563,359.840,
4671.03516,1220.598,5749.60693,359.840,
4671.12695,1219.598,5749.69873,359.840,
4671.21826,1219.598,5749.79004,359.840,
4671.30957,1219.598,5749.88184,359.840,
4671.40137,1219.598,5749.97314,358.840,
4671.49268,1218.598,5750.06445,359.840,
4671.58447,1218.598,5750.15625,358.840,
4671.67578,1218.598,5750.24756,358.840,
4671.76758,1217.598,5750.33936,358.840,
4671.85889,1218.598,5750.43066,358.840,
4671.95020,1217.598,5750.52246,358.840,
4672.04199,1217.598,5750.61377,358.840,
4672.13330,1218.598,5750.70557,358.840,
4672.22510,1217.598,5750.79688,357.840,
4672.31641,1217.598,5750.88818,357.840,
4672.40820,1216.598,5750.97998,357.840,
4672.49951,1216.598,5751.07129,357.840,
4672.59131,1216.598,5751.16309,357.840,
4672.68262,1215.598,5751.25439,357.840,
4672.77393,1216.598,5751.34619,357.840,
4672.86572,1215.598,5751.43750,357.840,
4672.95703,1215.598,5751.52881,357.840,
4673.04883,1214.598,5751.62061,357.840,
4673.14014,1215.598,5751.71191,356.840,
4673.23193,1215.598,5751.80371,356.840,
4673.32324,1215.598,5751.89502,356.840,
4673.41455,1214.598,5751.98682,356.840,
4673.50635,1214.598,5752.07813,356.840,
4673.59766,1215.598,5752.16943,356.840,
4673.68945,1214.598,5752.26123,355.840,
4673.78076,1213.598,5752.35254,355.840,
4673.87256,1213.598,5752.44434,355.840,
4673.96387,1213.598,5752.53564,355.840,
4674.05518,1212.598,5752.62744,355.840,
4674.14697,1212.598,5752.71875,355.840,
4674.23828,1212.598,5752.81055,354.840,
4674.33008,1212.598,5752.90186,355.840,
4674.42139,1211.598,5752.99316,354.840,
4674.51318,1211.598,5753.08496,354.840,
4674.60449,1211.598,5753.17627,354.840,
4674.69629,1211.598,5753.26807,354.840,
4674.78760,1211.598,5753.35938,354.840,
4674.87891,1211.598,5753.45117,354.840,
4674.97070,1211.598,5753.54248,353.840,
4675.06201,1211.598,5753.63379,353.840,
4675.15381,1210.598,5753.72559,353.840,
4675.24512,1210.598,5753.81689,353.840,
4675.33691,1210.598,5753.90869,353.840,
4675.42822,1210.598,5754.00000,353.840,
4675.51953,1209.598,5754.09180,353.840,
4675.61133,1209.598,5754.18311,352.840,
4675.70264,1209.598,5754.27441,353.840,
4675.79443,1209.598,5754.36621,352.840,
4675.88574,1209.598,5754.45752,352.840,
4675.97754,1208.598,5754.54932,352.840,
4676.06885,1208.598,5754.64063,352.840,
4676.16016,1208.598,5754.73242,351.840,
4676.25195,1207.598,5754.82373,352.840,
4676.34326,1207.598,5754.91504,351.840,
4676.43506,1207.598,5755.00684,351.840,
4676.52637,1208.598,5755.09814,351.840,
4676.61816,1207.598,5755.18994,351.840,
4676.70947,1206.598,5755.28125,351.840,
4676.80127,1207.598,5755.37305,351.840,
4676.89258,1206.598,5755.46436,351.840,
4676.98389,1206.598,5755.55615,351.840,
4677.07568,1206.598,5755.64746,351.840,
4677.16699,1206.598,5755.73877,351.840,
4677.25879,1205.598,5755.83057,351.840,
4677.35010,1205.598,5755.92188,351.840,
4677.44189,1205.598,5756.01367,351.840,
4677.53320,1204.598,5756.10498,352.840,
4677.62451,1205.598,5756.19678,352.840,
4677.71631,1204.598,5756.28809,352.840,
4677.80762,1204.598,5756.37939,353.840,
4677.89941,1204.598,5756.47119,354.840,
4677.99072,1204.598,5756.56250,353.840,
4678.08252,1204.598,5756.65430,353.840,
4678.17383,1203.598,5756.74561,353.840,
4678.26514,1203.598,5756.83740,353.840,
4678.35693,1203.598,5756.92871,353.840,
4678.44824,1203.598,5757.02002,352.840,
4678.54004,1202.598,5757.11182,352.840,
4678.63135,1202.598,5757.20313,352.840,
4678.72314,1202.598,5757.29492,351.840,
4678.81445,1201.598,5757.38623,351.840,
4678.90625,1202.598,5757.47803,351.840,
4678.99756,1201.598,5757.56934,350.840,
4679.08887,1201.598,5757.66113,349.840,
4679.18066,1201.598,5757.75244,350.840,
4679.27197,1201.598,5757.84375,349.840,
4679.36377,1200.598,5757.93555,349.840,
4679.45508,1201.598,5758.02686,349.840,
4679.54688,1200.598,5758.11865,349.840,
4679.63818,1200.598,5758.20996,349.840,
4679.72949,1200.598,5758.30176,348.840,
4679.82129,1199.598,5758.39307,348.840,
4679.91260,1199.598,5758.48438,348.840,
4680.00439,1199.598,5758.57617,348.840,
4680.09570,1199.598,5758.66748,348.840,
4680.18750,1198.598,5758.75928,347.840,
4680.27881,1198.598,5758.85059,347.840,
4680.37012,1198.598,5758.94238,347.840,
4680.46191,1197.598,5759.03369,347.840,
4680.55322,1197.598,5759.12500,347.840,
4680.64502,1197.598,5759.21680,347.840,
4680.73633,1197.598,5759.30811,347.840,
4680.82813,1196.598,5759.39990,346.840,
4680.91943,1197.598,5759.49121,346.840,
4681.01123,1197.598,5759.58301,346.840,
4681.10254,1197.598,5759.67432,346.840,
4681.19385,1197.598,5759.76611,345.840,
4681.28564,1198.598,5759.85742,346.840,
4681.37695,1198.598,5759.94873,345.840,
4681.46875,1197.598,5760.04053,346.840,
4681.56006,1197.598,5760.13184,346.840,
4681.65186,1197.598,5760.22363,345.840,
4681.74316,1197.598,5760.31494,345.840,
4681.83447,1197.598,5760.40674,345.840,
4681.92627,1196.598,5760.49805,345.840,
4682.01758,1195.598,5760.58936,345.840,
4682.10938,1195.598,5760.68115,345.840,
4682.20068,1195.598,5760.77246,345.840,
4682.29248,1194.598,5760.86426,345.840,
4682.38379,1194.598,5760.95557,344.840,
4682.47510,1194.598,5761.04736,344.840,
4682.56689,1193.598,5761.13867,344.840,
4682.65820,1193.598,5761.22998,344.840,
4682.75000,1193.598,5761.32178,344.840,
4682.84131,1193.598,5761.41309,343.840,
4682.93311,1192.598,5761.50488,344.840,
4683.02441,1192.598,5761.59619,344.840,
4683.11572,1192.598,5761.68799,343.840,
4683.20752,1192.598,5761.77930,343.840,
4683.29883,1191.598,5761.87109,343.840,
4683.39063,1191.598,5761.96240,343.840,
4683.48193,1190.598,5762.05371,343.840,
4683.57373,1189.598,5762.14551,343.840,
4683.66504,1189.598,5762.23682,343.840,
4683.75684,1189.598,5762.32861,342.840,
4683.84814,1189.598,5762.41992,342.840,
4683.93945,1189.598,5762.51172,342.840,
4684.03125,1188.598,5762.60303,342.840,
4684.12256,1188.598,5762.69434,342.840,
4684.21436,1188.598,5762.78613,342.840,
4684.30566,1188.598,5762.87744,342.840,
4684.39746,1188.598,5762.96924,341.840,
4684.48877,1188.598,5763.06055,342.840,
4684.58008,1188.598,5763.15234,342.840,
4684.67188,1188.598,5763.24365,341.840,
4684.76318,1187.598,5763.33496,341.840,
4684.85498,1187.598,5763.42676,341.840,
4684.94629,1188.598,5763.51807,342.840,
4685.03809,1187.598,5763.60986,341.840,
4685.12939,1187.598,5763.70117,341.840,
4685.22070,1187.598,5763.79297,341.840,
4685.31250,1187.598,5763.88428,340.840,
4685.40381,1186.598,5763.97607,340.840,
4685.49561,1186.598,5764.06738,340.840,
4685.58691,1186.598,5764.15869,340.840,
4685.67871,1186.598,5764.25049,340.840,
4685.77002,1186.598,5764.34180,340.840,
4685.86182,1186.598,5764.43359,340.840,
4685.95313,1186.598,5764.52490,340.840,
4686.04443,1185.598,5764.61670,339.840,
4686.13623,1185.598,5764.70801,340.840,
4686.22754,1184.598,5764.79932,339.840,
4686.31934,1184.598,5764.89111,339.840,
4686.41064,1184.598,5764.98242,339.840,
4686.50244,1184.598,5765.07422,339.840,
4686.59375,1184.598,5765.16553,338.840,
4686.68506,1184.598,5765.25732,339.840,
4686.77686,1184.598,5765.34863,339.840,
4686.86816,1184.598,5765.43994,339.840,
4686.95996,1183.598,5765.53174,339.840,
4687.05127,1183.598,5765.62305,339.840,
4687.14307,1183.598,5765.71484,338.840,
4687.23438,1183.598,5765.80615,338.840,
4687.32568,1182.598,5765.89795,338.840,
4687.41748,1182.598,5765.98926,339.840,
4687.50879,1182.598,5766.08105,338.840,
4687.60059,1182.598,5766.17236,338.840,
4687.69189,1181.598,5766.26367,337.840,
4687.78369,1181.598,5766.35547,337.840,
4687.87500,1181.598,5766.44678,337.840,
4687.96680,1181.598,5766.53857,337.840,
4688.05811,1181.598,5766.62988,337.840,
4688.14941,1180.598,5766.72168,336.840,
4688.24121,1181.598,5766.81299,337.840,
4688.33252,1180.598,5766.90430,337.840,
4688.42432,1179.598,5766.99609,337.840,
4688.51563,1179.598,5767.08740,336.840,
4688.60742,1180.598,5767.17920,337.840,
4688.69873,1179.598,5767.27051,336.840,
4688.79004,1179.598,5767.36230,336.840,
4688.88184,1179.598,5767.45361,337.840,
4688.97314,1179.598,5767.54492,336.840,
4689.06494,1178.598,5767.63672,336.840,
4689.15625,1178.598,5767.72803,336.840,
4689.24805,1178.598,5767.81982,336.840,
4689.33936,1178.598,5767.91113,336.840,
4689.43066,1178.598,5768.00293,336.840,
4689.52246,1177.598,5768.09424,336.840,
4689.61377,1177.598,5768.18555,335.840,
4689.70557,1177.598,5768.27734,335.840,
4689.79688,1177.598,5768.36865,335.840,
4689.88867,1177.598,5768.46045,335.840,
4689.97998,1176.598,5768.55176,335.840,
4690.07178,1176.598,5768.64355,335.840,
4690.16309,1176.598,5768.73486,335.840,
4690.25439,1176.598,5768.82666,334.840,
4690.34619,1175.598,5768.91797,335.840,
4690.43750,1175.598,5769.00928,334.840,
4690.52930,1175.598,5769.10107,334.840,
4690.62061,1175.598,5769.19238,334.840,
4690.71240,1175.598,5769.28418,334.840,
4690.80371,1175.598,5769.37549,334.840,
4690.89502,1174.598,5769.46729,334.840,
4690.98682,1174.598,5769.55859,333.840,
4691.07813,1174.598,5769.64990,334.840,
4691.16992,1174.598,5769.74170,333.840,
4691.26123,1173.598,5769.83301,333.840,
4691.35303,1173.598,5769.92480,333.840,
4691.44434,1173.598,5770.01611,333.840,
4691.53564,1172.598,5770.10791,333.840,
4691.62744,1172.598,5770.19922,333.840,
4691.71875,1173.598,5770.29053,333.840,
4691.81055,1172.598,5770.38232,333.840,
4691.90186,1172.598,5770.47363,333.840,
4691.99365,1171.598,5770.56543,332.840,
4692.08496,1171.598,5770.65674,332.840,
4692.17676,1171.598,5770.74854,332.840,
4692.26807,1171.598,5770.83984,332.840,
4692.35938,1171.598,5770.93164,331.840,
4692.45117,1171.598,5771.02295,331.840,
4692.54248,1171.598,5771.11426,332.840,
4692.63428,1171.598,5771.20605,331.840,
4692.72559,1170.598,5771.29736,331.840,
4692.81738,1170.598,5771.38916,331.840,
4692.90869,1170.598,5771.48047,331.840,
4693.00000,1169.598,5771.57227,331.840,
4693.09180,1169.598,5771.66357,332.840,
4693.18311,1169.598,5771.75488,331.840,
4693.27490,1169.598,5771.84668,332.840,
4693.36621,1169.598,5771.93799,331.840,
4693.45801,1168.598,5772.02979,331.840,
4693.54932,1168.598,5772.12109,330.840,
4693.64063,1168.598,5772.21289,330.840,
4693.73242,1167.598,5772.30420,330.840,
4693.82373,1168.598,5772.39551,330.840,
4693.91553,1167.598,5772.48730,329.840,
4694.00684,1167.598,5772.57861,331.840,
4694.09863,1167.598,5772.67041,330.840,
4694.18994,1167.598,5772.76172,331.840,
4694.28174,1167.598,5772.85352,331.840,
4694.37305,1167.598,5772.94482,331.840,
4694.46436,1166.598,5773.03662,331.840,
4694.55615,1166.598,5773.12793,331.840,
4694.64746,1166.598,5773.21924,331.840,
4694.73926,1165.598,5773.31104,332.840,
4694.83057,1165.598,5773.40234,331.840,
4694.92236,1165.598,5773.49414,331.840,
4695.01367,1165.598,5773.58545,330.840,
4695.10498,1164.598,5773.67725,330.840,
4695.19678,1164.598,5773.76855,330.840,
4695.28809,1165.598,5773.85986,330.840,
4695.37988,1163.598,5773.95166,330.840,
4695.47119,1164.598,5774.04297,329.840,
4695.56299,1165.598,5774.13477,329.840,
4695.65430,1163.598,5774.22607,328.840,
4695.74561,1163.598,5774.31787,328.840,
4695.83740,1163.598,5774.40918,328.840,
4695.92871,1163.598,5774.50049,328.840,
4696.02051,1163.598,5774.59229,328.840,
4696.11182,1162.598,5774.68359,327.840,
4696.20361,1162.598,5774.77539,328.840,
4696.29492,1162.598,5774.86670,327.840,
4696.38623,1162.598,5774.95850,328.840,
4696.47803,1161.598,5775.04980,329.840,
4696.56934,1161.598,5775.14160,329.840,
4696.66113,1161.598,5775.23291,330.840,
4696.75244,1161.598,5775.32422,331.840,
4696.84424,1160.598,5775.41602,330.840,
4696.93555,1161.598,5775.50732,330.840,
4697.02734,1161.598,5775.59912,330.840,
4697.11865,1160.598,5775.69043,330.840,
4697.20996,1159.598,5775.78223,329.840,
4697.30176,1160.598,5775.87354,329.840,
4697.39307,1159.598,5775.96484,329.840,
4697.48486,1159.598,5776.05664,328.840,
4697.57617,1159.598,5776.14795,327.840,
4697.66797,1159.598,5776.23975,327.840,
4697.75928,1158.598,5776.33105,327.840,
4697.85059,1158.598,5776.42285,326.840,
4697.94238,1158.598,5776.51416,326.840,
4698.03369,1158.598,5776.60547,326.840,
4698.12549,1157.598,5776.69727,325.840,
4698.21680,1157.598,5776.78857,325.840,
4698.30859,1157.598,5776.88037,325.840,
4698.39990,1157.598,5776.97168,325.840,
4698.49121,1157.598,5777.06348,324.840,
4698.58301,1157.598,5777.15479,325.840,
4698.67432,1156.598,5777.24658,324.840,
4698.76611,1156.598,5777.33789,324.840,
4698.85742,1156.598,5777.42920,324.840,
4698.94922,1156.598,5777.52100,324.840,
4699.04053,1156.598,5777.61230,324.840,
4699.13232,1155.598,5777.70410,324.840,
4699.22363,1155.598,5777.79541,324.840,
4699.31494,1155.598,5777.88721,324.840,
4699.40674,1155.598,5777.97852,323.840,
4699.49805,1155.598,5778.06982,323.840,
4699.58984,1154.598,5778.16162,323.840,
4699.68115,1154.598,5778.25293,324.840,
4699.77295,1154.598,5778.34473,323.840,
4699.86426,1154.598,5778.43604,323.840,
4699.95557,1155.598,5778.52783,323.840,
4700.04736,1154.598,5778.61914,322.840,
4700.13867,1154.598,5778.71045,322.840,
4700.23047,1154.598,5778.80225,323.840,
4700.32178,1154.598,5778.89355,322.840,
4700.41357,1154.598,5778.98535,322.840,
4700.50488,1154.598,5779.07666,322.840,
4700.59619,1154.598,5779.16846,323.840,
4700.68799,1154.598,5779.25977,322.840,
4700.77930,1152.598,5779.35156,322.840,
4700.87109,1152.598,5779.44287,322.840,
4700.96240,1152.598,5779.53418,321.840,
4701.05420,1152.598,5779.62598,322.840,
4701.14551,1151.598,5779.71729,321.840,
4701.23730,1152.598,5779.80908,321.840,
4701.32861,1151.598,5779.90039,321.840,
4701.41992,1151.598,5779.99219,321.840,
4701.51172,1151.598,5780.08350,320.840,
4701.60303,1151.598,5780.17480,321.840,
4701.69482,1150.598,5780.26660,320.840,
4701.78613,1150.598,5780.35791,320.840,
4701.87793,1149.598,5780.44971,320.840,
4701.96924,1149.598,5780.54102,320.840,
4702.06055,1149.598,5780.63281,321.840,
4702.15234,1148.598,5780.72412,320.840,
4702.24365,1148.598,5780.81543,320.840,
4702.33545,1147.598,5780.90723,320.840,
4702.42676,1147.598,5780.99854,320.840,
4702.51855,1147.598,5781.09033,320.840,
4702.60986,1147.598,5781.18164,320.840,
4702.70117,1146.598,5781.27344,320.840,
4702.79297,1146.598,5781.36475,319.840,
4702.88428,1147.598,5781.45605,319.840,
4702.97607,1146.598,5781.54785,319.840,
4703.06738,1145.598,5781.63916,318.840,
4703.15918,1145.598,5781.73096,319.840,
4703.25049,1145.598,5781.82227,319.840,
4703.34229,1145.598,5781.91406,319.840,
4703.43359,1145.598,5782.00537,319.840,
4703.52490,1144.598,5782.09717,320.840,
4703.61670,1144.598,5782.18848,319.840,
4703.70801,1144.598,5782.27979,318.840,
4703.79980,1144.598,5782.37158,318.840,
4703.89111,1143.598,5782.46289,319.840,
4703.98291,1143.598,5782.55469,318.840,
4704.07422,1143.598,5782.64600,318.840,
4704.16553,1143.598,5782.73779,318.840,
4704.25732,1143.598,5782.82910,317.840,
4704.34863,1144.598,5782.92041,317.840,
4704.44043,1142.598,5783.01221,317.840,
4704.53174,1143.598,5783.10352,317.840,
4704.62354,1143.598,5783.19531,317.840,
4704.71484,1143.598,5783.28662,317.840,
4704.80615,1142.598,5783.37842,316.840,
4704.89795,1142.598,5783.46973,316.840,
4704.98926,1142.598,5783.56104,317.840,
4705.08105,1142.598,5783.65283,317.840,
4705.17236,1142.598,5783.74414,316.840,
4705.26416,1141.598,5783.83594,316.840,
4705.35547,1141.598,5783.92725,316.840,
4705.44727,1141.598,5784.01904,316.840,
4705.53857,1141.598,5784.11035,316.840,
4705.62988,1140.598,5784.20215,316.840,
4705.72168,1140.598,5784.29346,316.840,
4705.81299,1141.598,5784.38477,316.840,
4705.90479,1140.598,5784.47656,315.840,
4705.99609,1140.598,5784.56787,315.840,
4706.08789,1139.598,5784.65967,315.840,
4706.17920,1139.598,5784.75098,315.840,
4706.27051,1139.598,5784.84277,315.840,
4706.36230,1139.598,5784.93408,315.840,
4706.45361,1139.598,5785.02539,315.840,
4706.54541,1138.598,5785.11719,315.840,
4706.63672,1139.598,5785.20850,314.840,
4706.72852,1138.598,5785.30029,314.840,
4706.81982,1138.598,5785.39160,315.840,
4706.91113,1138.598,5785.48340,315.840,
4707.00293,1137.598,5785.57471,314.840,
4707.09424,1137.598,5785.66602,314.840,
4707.18604,1137.598,5785.75781,314.840,
4707.27734,1138.598,5785.84912,314.840,
4707.36914,1136.598,5785.94092,313.840,
4707.46045,1136.598,5786.03223,314.840,
4707.55176,1136.598,5786.12402,314.840,
4707.64355,1136.598,5786.21533,314.840,
4707.73486,1135.598,5786.30713,313.840,
4707.82666,1136.598,5786.39844,313.840,
4707.91797,1136.598,5786.48975,314.840,
4708.00977,1135.598,5786.58154,313.840,
4708.10107,1135.598,5786.67285,312.840,
4708.19287,1135.598,5786.76465,313.840,
4708.28418,1135.598,5786.85596,312.840,
4708.37549,1134.598,5786.94775,313.840,
4708.46729,1134.598,5787.03906,313.840,
4708.55859,1135.598,5787.13037,312.840,
4708.65039,1134.598,5787.22217,312.840,
4708.74170,1134.598,5787.31348,312.840,
4708.83350,1134.598,5787.40527,312.840,
4708.92480,1134.598,5787.49658,312.840,
4709.01611,1133.598,5787.58838,312.840,
4709.10791,1133.598,5787.67969,312.840,
4709.19922,1133.598,5787.77100,311.840,
4709.29102,1133.598,5787.86279,311.840,
4709.38232,1132.598,5787.95410,312.840,
4709.47412,1132.598,5788.04590,311.840,
4709.56543,1132.598,5788.13721,311.840,
4709.65674,1131.598,5788.22900,311.840,
4709.74854,1131.598,5788.32031,311.840,
4709.83984,1131.598,5788.41211,310.840,
4709.93164,1131.598,5788.50342,311.840,
4710.02295,1130.598,5788.59473,311.840,
4710.11475,1131.598,5788.68652,311.840,
4710.20605,1131.598,5788.77783,311.840,
4710.29785,1130.598,5788.86963,310.840,
4710.38916,1130.598,5788.96094,310.840,
4710.48047,1130.598,5789.05273,310.840,
4710.57227,1129.598,5789.14404,310.840,
4710.66357,1130.598,5789.23535,310.840,
4710.75537,1129.598,5789.32715,310.840,
4710.84668,1129.598,5789.41846,310.840,
4710.93848,1129.598,5789.51025,310.840,
4711.02979,1128.598,5789.60156,309.840,
4711.12109,1128.598,5789.69336,309.840,
4711.21289,1128.598,5789.78467,309.840,
4711.30420,1128.598,5789.87598,309.840,
4711.39600,1128.598,5789.96777,309.840,
4711.48730,1127.598,5790.05908,309.840,
4711.57910,1127.598,5790.15088,309.840,
4711.67041,1128.598,5790.24219,308.840,
4711.76172,1127.598,5790.33398,308.840,
4711.85352,1127.598,5790.42529,309.840,
4711.94482,1127.598,5790.51709,308.840,
4712.03662,1127.598,5790.60840,308.840,
4712.12793,1126.598,5790.69971,308.840,
4712.21973,1126.598,5790.79150,308.840,
4712.31104,1126.598,5790.88281,309.840,
4712.40283,1126.598,5790.97461,308.840,
4712.49414,1125.598,5791.06592,308.840,
4712.58545,1126.598,5791.15771,308.840,
4712.67725,1125.598,5791.24902,308.840,
4712.76855,1125.598,5791.34033,308.840,
4712.86035,1125.598,5791.43213,307.840,
4712.95166,1125.598,5791.52344,308.840,
4713.04346,1125.598,5791.61523,307.840,
4713.13477,1125.598,5791.70654,307.840,
4713.22607,1124.598,5791.79834,307.840,
4713.31787,1124.598,5791.88965,307.840,
4713.40918,1123.598,5791.98096,306.840,
4713.50098,1124.598,5792.07275,306.840,
4713.59229,1123.598,5792.16406,306.840,
4713.68408,1123.598,5792.25586,306.840,
4713.77539,1123.598,5792.34717,306.840,
4713.86670,1123.598,5792.43896,306.840,
4713.95850,1122.598,5792.53027,306.840,
4714.04980,1122.598,5792.62158,306.840,
4714.14160,1121.598,5792.71338,305.840,
4714.23291,1122.598,5792.80469,306.840,
4714.32471,1121.598,5792.89648,305.840,
4714.41602,1121.598,5792.98779,305.840,
4714.50781,1121.598,5793.07959,305.840,
4714.59912,1122.598,5793.17090,305.840,
4714.69043,1120.598,5793.26270,305.840,
4714.78223,1120.598,5793.35400,305.840,
4714.87354,1120.598,5793.44531,306.840,
4714.96533,1120.598,5793.53711,306.840,
4715.05664,1120.598,5793.62842,307.840,
4715.14844,1120.598,5793.72021,308.840,
4715.23975,1120.598,5793.81152,308.840,
4715.33105,1119.598,5793.90332,308.840,
4715.42285,1119.598,5793.99463,309.840,
4715.51416,1119.598,5794.08594,309.840,
4715.60596,1119.598,5794.17773,308.840,
4715.69727,1119.598,5794.26904,309.840,
4715.78906,1119.598,5794.36084,308.840,
4715.88037,1119.598,5794.45215,307.840,
4715.97168,1118.598,5794.54395,307.840,
4716.06348,1118.598,5794.63525,306.840,
4716.15479,1118.598,5794.72656,306.840,
4716.24658,1117.598,5794.81836,306.840,
4716.33789,1117.598,5794.90967,305.840,
4716.42969,1117.598,5795.00146,305.840,
4716.52100,1117.598,5795.09277,304.840,
4716.61279,1116.598,5795.18457,305.840,
4716.70410,1117.598,5795.27588,304.840,
4716.79541,1116.598,5795.36768,303.840,
4716.88721,1116.598,5795.45898,303.840,
4716.97852,1116.598,5795.55029,303.840,
4717.07031,1116.598,5795.64209,303.840,
4717.16162,1115.598,5795.73340,303.840,
4717.25342,1115.598,5795.82520,303.840,
4717.34473,1115.598,5795.91650,303.840,
4717.43604,1115.598,5796.00830,302.840,
4717.52783,1115.598,5796.09961,302.840,
4717.61914,1114.598,5796.19092,302.840,
4717.71094,1115.598,5796.28271,301.840,
4717.80225,1114.598,5796.37402,301.840,
4717.89404,1114.598,5796.46582,301.840,
4717.98535,1114.598,5796.55713,301.840,
4718.07666,1113.598,5796.64893,301.840,
4718.16846,1113.598,5796.74023,301.840,
4718.25977,1113.598,5796.83154,301.840,
4718.35156,1113.598,5796.92334,301.840,
4718.44287,1113.598,5797.01465,301.840,
4718.53467,1112.598,5797.10645,301.840,
4718.62598,1112.598,5797.19775,300.840,
4718.71777,1112.598,5797.28955,301.840,
4718.80908,1113.598,5797.38086,300.840,
4718.90039,1113.598,5797.47266,300.840,
4718.99219,1113.598,5797.56396,299.840,
4719.08350,1113.598,5797.65527,300.840,
4719.17529,1113.598,5797.74707,300.840,
4719.26660,1113.598,5797.83838,300.840,
4719.35840,1112.598,5797.93018,299.840,
4719.44971,1113.598,5798.02148,300.840,
4719.54102,1112.598,5798.11328,299.840,
4719.63281,1112.598,5798.20459,300.840,
4719.72412,1111.598,5798.29590,299.840,
4719.81592,1111.598,5798.38770,299.840,
4719.90723,1111.598,5798.47900,299.840,
4719.99902,1111.598,5798.57080,299.840,
4720.09033,1110.598,5798.66211,299.840,
4720.18164,1109.598,5798.75391,299.840,
4720.27344,1110.598,5798.84521,299.840,
4720.36475,1110.598,5798.93652,298.840,
4720.45654,1109.598,5799.02832,298.840,
4720.54785,1109.598,5799.11963,298.840,
4720.63965,1109.598,5799.21143,298.840,
4720.73096,1108.598,5799.30273,298.840,
4720.82227,1108.598,5799.39453,298.840,
4720.91406,1108.598,5799.48584,298.840,
4721.00537,1107.598,5799.57764,298.840,
4721.09717,1107.598,5799.66895,298.840,
4721.18848,1108.598,5799.76025,298.840,
4721.28027,1107.598,5799.85205,298.840,
4721.37158,1107.598,5799.94336,297.840,
4721.46338,1107.598,5800.03516,297.840,
4721.55469,1107.598,5800.12646,297.840,
4721.64600,1107.598,5800.21826,297.840,
4721.73779,1106.598,5800.30957,296.840,
4721.82910,1106.598,5800.40088,297.840,
4721.92090,1107.598,5800.49268,296.840,
4722.01221,1106.598,5800.58398,296.840,
4722.10400,1106.598,5800.67578,296.840,
4722.19531,1106.598,5800.76709,296.840,
4722.28662,1105.598,5800.85889,296.840,
4722.37842,1104.598,5800.95020,296.840,
4722.46973,1105.598,5801.04150,296.840,
4722.56152,1105.598,5801.13330,296.840,
4722.65283,1104.598,5801.22461,296.840,
4722.74463,1104.598,5801.31641,296.840,
4722.83594,1103.598,5801.40771,296.840,
4722.92725,1103.598,5801.49951,296.840,
4723.01904,1103.598,5801.59082,295.840,
4723.11035,1103.598,5801.68262,295.840,
4723.20215,1102.598,5801.77393,295.840,
4723.29346,1102.598,5801.86523,295.840,
4723.38525,1103.598,5801.95703,295.840,
4723.47656,1102.598,5802.04834,294.840,
4723.56836,1102.598,5802.14014,295.840,
4723.65967,1102.598,5802.23145,295.840,
4723.75098,1102.598,5802.32324,294.840,
4723.84277,1101.598,5802.41455,294.840,
4723.93408,1102.598,5802.50586,294.840,
4724.02588,1101.598,5802.59766,295.840,
4724.11719,1100.598,5802.68896,294.840,
4724.20898,1101.598,5802.78076,294.840,
4724.30029,1101.598,5802.87207,294.840,
4724.39160,1100.598,5802.96387,294.840,
4724.48340,1101.598,5803.05518,294.840,
4724.57471,1100.598,5803.14648,293.840,
4724.66650,1100.598,5803.23828,293.840,
4724.75781,1099.598,5803.32959,293.840,
4724.84961,1100.598,5803.42139,293.840,
4724.94092,1100.598,5803.51270,292.840,
4725.03223,1099.598,5803.60449,293.840,
4725.12402,1099.598,5803.69580,293.840,
4725.21533,1099.598,5803.78760,293.840,
4725.30713,1098.598,5803.87891,292.840,
4725.39844,1098.598,5803.97021,292.840,
4725.49023,1099.598,5804.06201,293.840,
4725.58154,1098.598,5804.15332,292.840,
4725.67334,1097.598,5804.24512,292.840,
4725.76465,1097.598,5804.33643,292.840,
4725.85596,1097.598,5804.42822,291.840,
4725.94775,1097.598,5804.51953,292.840,
4726.03906,1097.598,5804.61084,291.840,
4726.13086,1096.598,5804.70264,291.840,
4726.22217,1097.598,5804.79395,291.840,
4726.31396,1097.598,5804.88574,291.840,
4726.40527,1096.598,5804.97705,290.840,
4726.49658,1096.598,5805.06885,291.840,
4726.58838,1096.598,5805.16016,291.840,
4726.67969,1096.598,5805.25146,291.840,
4726.77148,1095.598,5805.34326,290.840,
4726.86279,1095.598,5805.43457,290.840,
4726.95459,1095.598,5805.52637,291.840,
4727.04590,1095.598,5805.61768,290.840,
4727.13721,1095.598,5805.70947,290.840,
4727.22900,1095.598,5805.80078,290.840,
4727.32031,1094.598,5805.89209,290.840,
4727.41211,1095.598,5805.98389,290.840,
4727.50342,1094.598,5806.07520,289.840,
4727.59521,1094.598,5806.16699,290.840,
4727.68652,1094.598,5806.25830,289.840,
4727.77832,1094.598,5806.35010,289.840,
4727.86963,1094.598,5806.44141,289.840,
4727.96094,1093.598,5806.53320,290.840,
4728.05273,1093.598,5806.62451,289.840,
4728.14404,1093.598,5806.71582,289.840,
4728.23584,1093.598,5806.80762,289.840,
4728.32715,1092.598,5806.89893,289.840,
4728.41895,1093.598,5806.99072,289.840,
4728.51025,1092.598,5807.08203,289.840,
4728.60156,1092.598,5807.17383,289.840,
4728.69336,1091.598,5807.26514,289.840,
4728.78467,1091.598,5807.35645,288.840,
4728.87646,1091.598,5807.44824,288.840,
4728.96777,1091.598,5807.53955,288.840,
4729.05957,1090.598,5807.63135,288.840,
4729.15088,1090.598,5807.72266,288.840,
4729.24219,1090.598,5807.81445,288.840,
4729.33398,1091.598,5807.90576,288.840,
4729.42529,1090.598,5807.99707,287.840,
4729.51709,1090.598,5808.08887,288.840,
4729.60840,1090.598,5808.18018,287.840,
4729.70020,1090.598,5808.27197,287.840,
4729.79150,1090.598,5808.36328,287.840,
4729.88330,1089.598,5808.45508,288.840,
4729.97461,1089.598,5808.54639,287.840,
4730.06592,1089.598,5808.63818,287.840,
4730.15771,1089.598,5808.72949,287.840,
4730.24902,1089.598,5808.82080,287.840,
4730.34082,1088.598,5808.91260,287.840,
4730.43213,1088.598,5809.00391,287.840,
4730.52393,1088.598,5809.09570,286.840,
4730.61523,1088.598,5809.18701,286.840,
4730.70654,1088.598,5809.27881,285.840,
4730.79834,1087.598,5809.37012,285.840,
4730.88965,1088.598,5809.46143,284.840,
4730.98145,1087.598,5809.55322,284.840,
4731.07275,1087.598,5809.64453,283.840,
4731.16455,1086.598,5809.73633,283.840,
4731.25586,1087.598,5809.82764,283.840,
4731.34717,1086.598,5809.91943,284.840,
4731.43896,1086.598,5810.01074,283.840,
4731.53027,1086.598,5810.10205,283.840,
4731.62207,1086.598,5810.19385,283.840,
4731.71338,1086.598,5810.28516,283.840,
4731.80518,1086.598,5810.37695,284.840,
4731.89648,1085.598,5810.46826,284.840,
4731.98828,1085.598,5810.56006,284.840,
4732.07959,1085.598,5810.65137,283.840,
4732.17090,1085.598,5810.74316,283.840,
4732.26270,1085.598,5810.83447,283.840,
4732.35400,1084.598,5810.92578,284.840,
4732.44580,1084.598,5811.01758,284.840,
4732.53711,1084.598,5811.10889,284.840,
4732.62891,1083.598,5811.20068,284.840,
4732.72021,1083.598,5811.29199,283.840,
4732.81152,1083.598,5811.38379,284.840,
4732.90332,1083.598,5811.47510,284.840,
4732.99463,1083.598,5811.56641,284.840,
4733.08643,1082.598,5811.65820,285.840,
4733.17773,1082.598,5811.74951,285.840,
4733.26953,1082.598,5811.84131,286.840,
4733.36084,1082.598,5811.93262,286.840,
4733.45215,1081.598,5812.02441,287.840,
4733.54395,1082.598,5812.11572,287.840,
4733.63525,1082.598,5812.20703,287.840,
4733.72705,1082.598,5812.29883,287.840,
4733.81836,1081.598,5812.39014,286.840,
4733.91016,1081.598,5812.48193,286.840,
4734.00146,1081.598,5812.57324,285.840,
4734.09277,1081.598,5812.66504,286.840,
4734.18457,1081.598,5812.75635,285.840,
4734.27588,1080.598,5812.84814,285.840,
4734.36768,1080.598,5812.93945,284.840,
4734.45898,1080.598,5813.03076,285.840,
4734.55078,1080.598,5813.12256,284.840,
4734.64209,1080.598,5813.21387,283.840,
4734.73389,1079.598,5813.30566,283.840,
4734.82520,1079.598,5813.39697,283.840,
4734.91650,1079.598,5813.48877,283.840,
4735.00830,1079.598,5813.58008,282.840,
4735.09961,1079.598,5813.67139,282.840,
4735.19141,1078.598,5813.76318,282.840,
4735.28271,1078.598,5813.85449,281.840,
4735.37451,1078.598,5813.94629,281.840,
4735.46582,1078.598,5814.03760,281.840,
4735.55713,1078.598,5814.12939,281.840,
4735.64893,1077.598,5814.22070,280.840,
4735.74023,1077.598,5814.31201,281.840,
4735.83203,1077.598,5814.40381,281.840,
4735.92334,1077.598,5814.49512,281.840,
4736.01514,1077.598,5814.58691,280.840,
4736.10645,1077.598,5814.67822,280.840,
4736.19775,1077.598,5814.77002,280.840,
4736.28955,1076.598,5814.86133,279.840,
4736.38086,1076.598,5814.95313,280.840,
4736.47266,1076.598,5815.04443,279.840,
4736.56396,1076.598,5815.13574,279.840,
4736.65576,1076.598,5815.22754,279.840,
4736.74707,1076.598,5815.31885,279.840,
4736.83887,1075.598,5815.41064,279.840,
4736.93018,1075.598,5815.50195,279.840,
4737.02148,1075.598,5815.59375,278.840,
4737.11328,1075.598,5815.68506,278.840,
4737.20459,1075.598,5815.77637,279.840,
4737.29639,1074.598,5815.86816,278.840,
4737.38770,1074.598,5815.95947,278.840,
4737.47949,1074.598,5816.05127,278.840,
4737.57080,1074.598,5816.14258,278.840,
4737.66211,1074.598,5816.23438,278.840,
4737.75391,1074.598,5816.32568,278.840,
4737.84521,1074.598,5816.41699,278.840,
4737.93701,1074.598,5816.50879,278.840,
4738.02832,1076.598,5816.60010,278.840,
4738.12012,1075.598,5816.69189,278.840,
4738.21143,1076.598,5816.78320,277.840,
4738.30273,1076.598,5816.87500,277.840,
4738.39453,1075.598,5816.96631,277.840,
4738.48584,1075.598,5817.05811,277.840,
4738.57764,1075.598,5817.14941,277.840,
4738.66895,1074.598,5817.24072,277.840,
4738.76074,1075.598,5817.33252,277.840,
4738.85205,1074.598,5817.42383,276.840,
4738.94385,1074.598,5817.51563,277.840,
4739.03516,1073.598,5817.60693,277.840,
4739.12646,1073.598,5817.69873,277.840,
4739.21826,1072.598,5817.79004,277.840,
4739.30957,1072.598,5817.88135,276.840,
4739.40137,1072.598,5817.97314,276.840,
4739.49268,1071.598,5818.06445,276.840,
4739.58447,1071.598,5818.15625,276.840,
4739.67578,1071.598,5818.24756,276.840,
4739.76709,1070.598,5818.33936,276.840,
4739.85889,1070.598,5818.43066,276.840,
4739.95020,1069.598,5818.52197,276.840,
4740.04199,1070.598,5818.61377,276.840,
4740.13330,1069.598,5818.70508,276.840,
4740.22510,1068.598,5818.79688,275.840,
4740.31641,1067.598,5818.88818,275.840,
4740.40771,1066.598,5818.97998,275.840,
4740.49951,1065.598,5819.07129,275.840,
4740.59082,1065.598,5819.16260,275.840,
4740.68262,1064.598,5819.25439,275.840,
4740.77393,1064.598,5819.34570,275.840,
4740.86572,1064.598,5819.43750,275.840,
4740.95703,1064.598,5819.52881,275.840,
4741.04883,1064.598,5819.62061,274.840,
4741.14014,1064.598,5819.71191,275.840,
4741.23145,1064.598,5819.80371,275.840,
4741.32324,1064.598,5819.89502,274.840,
4741.41455,1064.598,5819.98633,274.840,
4741.50635,1064.598,5820.07813,273.840,
4741.59766,1065.598,5820.16943,274.840,
4741.68945,1065.598,5820.26123,274.840,
4741.78076,1064.598,5820.35254,273.840,
4741.87207,1065.598,5820.44434,273.840,
4741.96387,1064.598,5820.53564,273.840,
4742.05518,1064.598,5820.62695,273.840,
4742.14697,1064.598,5820.71875,273.840,
4742.23828,1064.598,5820.81006,273.840,
4742.33008,1064.598,5820.90186,273.840,
4742.42139,1064.598,5820.99316,273.840,
4742.51270,1064.598,5821.08496,273.840,
4742.60449,1064.598,5821.17627,273.840,
4742.69580,1064.598,5821.26758,272.840,
4742.78760,1064.598,5821.35938,272.840,
4742.87891,1064.598,5821.45068,272.840,
4742.97070,1063.598,5821.54248,272.840,
4743.06201,1063.598,5821.63379,272.840,
4743.15381,1063.598,5821.72559,272.840,
4743.24512,1063.598,5821.81689,272.840,
4743.33643,1062.598,5821.90869,272.840,
4743.42822,1062.598,5822.00000,272.840,
4743.51953,1062.598,5822.09131,272.840,
4743.61133,1062.598,5822.18311,271.840,
4743.70264,1062.598,5822.27441,271.840,
4743.79443,1062.598,5822.36621,271.840,
4743.88574,1062.598,5822.45752,271.840,
4743.97705,1062.598,5822.54932,271.840,
4744.06885,1061.598,5822.64063,271.840,
4744.16016,1061.598,5822.73193,271.840,
4744.25195,1061.598,5822.82373,271.840,
4744.34326,1061.598,5822.91504,271.840,
4744.43506,1061.598,5823.00684,271.840,
4744.52637,1060.598,5823.09814,271.840,
4744.61768,1060.598,5823.18994,270.840,
4744.70947,1059.598,5823.28125,271.840,
4744.80078,1060.598,5823.37256,270.840,
4744.89258,1059.598,5823.46436,270.840,
4744.98389,1059.598,5823.55566,270.840,
4745.07568,1059.598,5823.64746,270.840,
4745.16699,1058.598,5823.73877,270.840,
4745.25830,1058.598,5823.83057,270.840,
4745.35010,1059.598,5823.92188,270.840,
4745.44141,1058.598,5824.01367,270.840,
4745.53320,1058.598,5824.10498,270.840,
4745.62451,1058.598,5824.19629,270.840,
4745.71631,1058.598,5824.28809,269.840,
4745.80762,1058.598,5824.37939,269.840,
4745.89941,1058.598,5824.47119,269.840,
4745.99072,1058.598,5824.56250,269.840,
4746.08203,1057.598,5824.65430,269.840,
4746.17383,1057.598,5824.74561,268.840,
4746.26514,1057.598,5824.83691,269.840,
4746.35693,1058.598,5824.92871,269.840,
4746.44824,1057.598,5825.02002,268.840,
4746.54004,1057.598,5825.11182,269.840,
4746.63135,1057.598,5825.20313,269.840,
4746.72266,1056.598,5825.29492,268.840,
4746.81445,1056.598,5825.38623,268.840,
4746.90576,1056.598,5825.47754,268.840,
4746.99756,1056.598,5825.56934,268.840,
4747.08887,1056.598,5825.66064,267.840,
4747.18066,1055.598,5825.75244,268.840,
4747.27197,1055.598,5825.84375,267.840,
4747.36328,1055.598,5825.93555,267.840,
4747.45508,1055.598,5826.02686,268.840,
4747.54639,1055.598,5826.11865,267.840,
4747.63818,1054.598,5826.20996,267.840,
4747.72949,1054.598,5826.30127,267.840,
4747.82129,1054.598,5826.39307,267.840,
4747.91260,1054.598,5826.48438,267.840,
4748.00439,1053.598,5826.57617,267.840,
4748.09570,1053.598,5826.66748,267.840,
4748.18701,1054.598,5826.75928,267.840,
4748.27881,1053.598,5826.85059,267.840,
4748.37012,1053.598,5826.94189,266.840,
4748.46191,1053.598,5827.03369,267.840,
4748.55322,1052.598,5827.12500,266.840,
4748.64502,1052.598,5827.21680,266.840,
4748.73633,1052.598,5827.30811,266.840,
4748.82764,1052.598,5827.39990,266.840,
4748.91943,1052.598,5827.49121,266.840,
4749.01074,1051.598,5827.58252,265.840,
4749.10254,1051.598,5827.67432,265.840,
4749.19385,1051.598,5827.76563,264.840,
4749.28564,1051.598,5827.85742,264.840,
4749.37695,1051.598,5827.94873,264.840,
4749.46826,1051.598,5828.04053,264.840,
4749.56006,1051.598,5828.13184,264.840,
4749.65137,1050.598,5828.22363,264.840,
4749.74316,1051.598,5828.31494,264.840,
4749.83447,1050.598,5828.40625,264.840,
4749.92627,1050.598,5828.49805,264.840,
4750.01758,1050.598,5828.58936,264.840,
4750.10938,1050.598,5828.68115,263.840,
4750.20068,1050.598,5828.77246,263.840,
4750.29199,1049.598,5828.86426,263.840,
4750.38379,1049.598,5828.95557,264.840,
4750.47510,1049.598,5829.04688,263.840,
4750.56689,1049.598,5829.13867,264.840,
4750.65820,1048.598,5829.22998,263.840,
4750.75000,1048.598,5829.32178,264.840,
4750.84131,1048.598,5829.41309,264.840,
4750.93262,1048.598,5829.50488,264.840,
4751.02441,1048.598,5829.59619,263.840,
4751.11572,1048.598,5829.68750,263.840,
4751.20752,1048.598,5829.77930,263.840,
4751.29883,1047.598,5829.87061,264.840,
4751.39063,1048.598,5829.96240,263.840,
4751.48193,1047.598,5830.05371,263.840,
4751.57324,1047.598,5830.14551,263.840,
4751.66504,1047.598,5830.23682,263.840,
4751.75635,1047.598,5830.32813,263.840,
4751.84814,1047.598,5830.41992,263.840,
4751.93945,1046.598,5830.51123,262.840,
4752.03125,1046.598,5830.60303,262.840,
4752.12256,1046.598,5830.69434,262.840,
4752.21436,1045.598,5830.78613,262.840,
4752.30566,1045.598,5830.87744,262.840,
4752.39697,1045.598,5830.96924,261.840,
4752.48877,1045.598,5831.06055,262.840,
4752.58008,1045.598,5831.15186,261.840,
4752.67188,1045.598,5831.24365,262.840,
4752.76318,1045.598,5831.33496,261.840,
4752.85498,1044.598,5831.42676,261.840,
4752.94629,1044.598,5831.51807,261.840,
4753.03760,1044.598,5831.60986,261.840,
4753.12939,1044.598,5831.70117,261.840,
4753.22070,1043.598,5831.79248,261.840,
4753.31250,1044.598,5831.88428,261.840,
4753.40381,1044.598,5831.97559,261.840,
4753.49561,1043.598,5832.06738,260.840,
4753.58691,1043.598,5832.15869,260.840,
4753.67822,1043.598,5832.25049,261.840,
4753.77002,1042.598,5832.34180,261.840,
4753.86133,1042.598,5832.43311,260.840,
4753.95313,1042.598,5832.52490,260.840,
4754.04443,1042.598,5832.61621,260.840,
4754.13623,1042.598,5832.70801,260.840,
4754.22754,1042.598,5832.79932,260.840,
4754.31934,1041.598,5832.89111,260.840,
4754.41064,1041.598,5832.98242,259.840,
4754.50195,1042.598,5833.07422,259.840,
4754.59375,1041.598,5833.16553,260.840,
4754.68506,1041.598,5833.25684,259.840,
4754.77686,1041.598,5833.34863,260.840,
4754.86816,1041.598,5833.43994,260.840,
4754.95996,1040.598,5833.53174,260.840,
4755.05127,1040.598,5833.62305,259.840,
4755.14258,1040.598,5833.71484,259.840,
4755.23438,1040.598,5833.80615,259.840,
4755.32568,1040.598,5833.89746,259.840,
4755.41748,1039.598,5833.98926,259.840,
4755.50879,1039.598,5834.08057,259.840,
4755.60059,1039.598,5834.17236,259.840,
4755.69189,1039.598,5834.26367,259.840,
4755.78320,1039.598,5834.35547,258.840,
4755.87500,1038.598,5834.44678,258.840,
4755.96631,1038.598,5834.53809,258.840,
4756.05811,1038.598,5834.62988,258.840,
4756.14941,1038.598,5834.72119,258.840,
4756.24121,1038.598,5834.81299,258.840,
4756.33252,1038.598,5834.90430,258.840,
4756.42432,1037.598,5834.99609,257.840,
4756.51563,1037.598,5835.08740,257.840,
4756.60693,1037.598,5835.17920,257.840,
4756.69873,1037.598,5835.27051,257.840,
4756.79004,1037.598,5835.36182,257.840,
4756.88184,1037.598,5835.45361,258.840,
4756.97314,1037.598,5835.54492,257.840,
4757.06494,1036.598,5835.63672,257.840,
4757.15625,1036.598,5835.72803,256.840,
4757.24756,1035.598,5835.81982,257.840,
4757.33936,1036.598,5835.91113,257.840,
4757.43066,1035.598,5836.00244,257.840,
4757.52246,1035.598,5836.09424,256.840,
4757.61377,1035.598,5836.18555,256.840,
4757.70557,1035.598,5836.27734,256.840,
4757.79688,1034.598,5836.36865,257.840,
4757.88818,1034.598,5836.46045,256.840,
4757.97998,1034.598,5836.55176,256.840,
4758.07129,1034.598,5836.64307,256.840,
4758.16309,1033.598,5836.73486,256.840,
4758.25439,1033.598,5836.82617,256.840,
4758.34619,1033.598,5836.91797,256.840,
4758.43750,1033.598,5837.00928,256.840,
4758.52881,1034.598,5837.10107,256.840,
4758.62061,1033.598,5837.19238,255.840,
4758.71191,1032.598,5837.28418,255.840,
4758.80371,1033.598,5837.37549,255.840,
4758.89502,1033.598,5837.46680,256.840,
4758.98682,1033.598,5837.55859,255.840,
4759.07813,1033.598,5837.64990,255.840,
4759.16992,1032.598,5837.74170,256.840,
4759.26123,1032.598,5837.83301,255.840,
4759.35254,1032.598,5837.92480,255.840,
4759.44434,1032.598,5838.01611,255.840,
4759.53564,1033.598,5838.10742,255.840,
4759.62744,1033.598,5838.19922,254.840,
4759.71875,1033.598,5838.29053,255.840,
4759.81055,1032.598,5838.38232,254.840,
4759.90186,1032.598,5838.47363,254.840,
4759.99316,1033.598,5838.56543,254.840,
4760.08496,1031.598,5838.65674,254.840,
4760.17627,1031.598,5838.74805,254.840,
4760.26807,1031.598,5838.83984,254.840,
4760.35938,1030.598,5838.93115,253.840,
4760.45117,1030.598,5839.02295,253.840,
4760.54248,1030.598,5839.11426,253.840,
4760.63379,1029.598,5839.20605,253.840,
4760.72559,1029.598,5839.29736,253.840,
4760.81689,1029.598,5839.38916,253.840,
4760.90869,1029.598,5839.48047,252.840,
4761.00000,1029.598,5839.57178,253.840,
4761.09180,1028.598,5839.66357,253.840,
4761.18311,1028.598,5839.75488,252.840,
4761.27490,1028.598,5839.84668,253.840,
4761.36621,1028.598,5839.93799,252.840,
4761.45752,1029.598,5840.02979,252.840,
4761.54932,1028.598,5840.12109,252.840,
4761.64063,1028.598,5840.21240,252.840,
4761.73242,1027.598,5840.30420,252.840,
4761.82373,1027.598,5840.39551,252.840,
4761.91553,1027.598,5840.48730,252.840,
4762.00684,1027.598,5840.57861,252.840,
4762.09814,1027.598,5840.67041,252.840,
4762.18994,1027.598,5840.76172,252.840,
4762.28125,1026.598,5840.85303,252.840,
4762.37305,1026.598,5840.94482,252.840,
4762.46436,1026.598,5841.03613,252.840,
4762.55615,1026.598,5841.12793,252.840,
4762.64746,1025.598,5841.21924,252.840,
4762.73877,1026.598,5841.31104,252.840,
4762.83057,1025.598,5841.40234,251.840,
4762.92188,1025.598,5841.49414,251.840,
4763.01367,1024.598,5841.58545,252.840,
4763.10498,1025.598,5841.67676,251.840,
4763.19678,1024.598,5841.76855,251.840,
4763.28809,1025.598,5841.85986,251.840,
4763.37988,1024.598,5841.95166,251.840,
4763.47119,1024.598,5842.04297,250.840,
4763.56250,1024.598,5842.13477,252.840,
4763.65430,1023.598,5842.22607,250.840,
4763.74561,1023.598,5842.31738,251.840,
4763.83740,1023.598,5842.40918,250.840,
4763.92871,1022.598,5842.50049,250.840,
4764.02051,1023.598,5842.59229,250.840,
4764.11182,1023.598,5842.68359,250.840,
4764.20313,1022.598,5842.77539,250.840,
4764.29492,1022.598,5842.86670,249.840,
4764.38623,1022.598,5842.95801,249.840,
4764.47803,1022.598,5843.04980,249.840,
4764.56934,1022.598,5843.14111,250.840,
4764.66113,1022.598,5843.23291,249.840,
4764.75244,1021.598,5843.32422,249.840,
4764.84375,1022.598,5843.41602,249.840,
4764.93555,1022.598,5843.50732,250.840,
4765.02686,1020.598,5843.59863,250.840,
4765.11865,1021.598,5843.69043,249.840,
4765.20996,1020.598,5843.78174,249.840,
4765.30176,1020.598,5843.87354,249.840,
4765.39307,1020.598,5843.96484,249.840,
4765.48486,1020.598,5844.05664,249.840,
4765.57617,1020.598,5844.14795,249.840,
4765.66748,1019.598,5844.23975,249.840,
4765.75928,1020.598,5844.33105,249.840,
4765.85059,1020.598,5844.42236,248.840,
4765.94238,1019.598,5844.51416,248.840,
4766.03369,1019.598,5844.60547,248.840,
4766.12549,1019.598,5844.69727,248.840,
4766.21680,1018.598,5844.78857,248.840,
4766.30811,1018.598,5844.88037,248.840,
4766.39990,1018.598,5844.97168,247.840,
4766.49121,1018.598,5845.06299,248.840,
4766.58301,1017.598,5845.15479,247.840,
4766.67432,1018.598,5845.24609,246.840,
4766.76611,1017.598,5845.33789,246.840,
4766.85742,1017.598,5845.42920,246.840,
4766.94873,1017.598,5845.52100,245.840,
4767.04053,1017.598,5845.61230,245.840,
4767.13184,1016.598,5845.70361,245.840,
4767.22363,1017.598,5845.79541,245.840,
4767.31494,1017.598,5845.88672,244.840,
4767.40674,1016.598,5845.97852,245.840,
4767.49805,1016.598,5846.06982,245.840,
4767.58984,1016.598,5846.16162,245.840,
4767.68115,1016.598,5846.25293,245.840,
4767.77246,1015.598,5846.34473,245.840,
4767.86426,1015.598,5846.43604,245.840,
4767.95557,1015.598,5846.52734,246.840,
4768.04736,1016.598,5846.61914,246.840,
4768.13867,1015.598,5846.71045,245.840,
4768.23047,1014.598,5846.80225,245.840,
4768.32178,1014.598,5846.89355,245.840,
4768.41309,1015.598,5846.98535,246.840,
4768.50488,1015.598,5847.07666,245.840,
4768.59619,1014.598,5847.16797,246.840,
4768.68799,1014.598,5847.25977,246.840,
4768.77930,1014.598,5847.35107,246.840,
4768.87109,1014.598,5847.44287,246.840,
4768.96240,1014.598,5847.53418,247.840,
4769.05371,1013.598,5847.62598,247.840,
4769.14551,1013.598,5847.71729,248.840,
4769.23682,1013.598,5847.80859,248.840,
4769.32861,1013.598,5847.90039,248.840,
4769.41992,1013.598,5847.99170,248.840,
4769.51172,1013.598,5848.08350,248.840,
4769.60303,1012.598,5848.17480,247.840,
4769.69434,1012.598,5848.26660,247.840,
4769.78613,1012.598,5848.35791,247.840,
4769.87744,1011.598,5848.44971,247.840,
4769.96924,1012.598,5848.54102,246.840,
4770.06055,1011.598,5848.63232,245.840,
4770.15234,1011.598,5848.72412,245.840,
4770.24365,1011.598,5848.81543,244.840,
4770.33545,1012.598,5848.90723,244.840,
4770.42676,1011.598,5848.99854,244.840,
4770.51807,1011.598,5849.09033,244.840,
4770.60986,1011.598,5849.18164,244.840,
4770.70117,1011.598,5849.27295,244.840,
4770.79297,1010.598,5849.36475,243.840,
4770.88428,1010.598,5849.45605,244.840,
4770.97607,1010.598,5849.54785,243.840,
4771.06738,1009.598,5849.63916,244.840,
4771.15869,1009.598,5849.73096,244.840,
4771.25049,1009.598,5849.82227,243.840,
4771.34180,1009.598,5849.91357,243.840,
4771.43359,1009.598,5850.00537,243.840,
4771.52490,1008.598,5850.09668,243.840,
4771.61670,1009.598,5850.18848,243.840,
4771.70801,1009.598,5850.27979,243.840,
4771.79932,1009.598,5850.37158,242.840,
4771.89111,1009.598,5850.46289,242.840,
4771.98242,1008.598,5850.55469,242.840,
4772.07422,1008.598,5850.64600,242.840,
4772.16553,1008.598,5850.73730,242.840,
4772.25732,1008.598,5850.82910,242.840,
4772.34863,1008.598,5850.92041,243.840,
4772.44043,1007.598,5851.01221,242.840,
4772.53174,1008.598,5851.10352,242.840,
4772.62305,1007.598,5851.19531,242.840,
4772.71484,1007.598,5851.28662,242.840,
4772.80615,1007.598,5851.37793,242.840,
4772.89795,1006.598,5851.46973,241.840,
4772.98926,1007.598,5851.56104,242.840,
4773.08105,1006.598,5851.65283,242.840,
4773.17236,1007.598,5851.74414,241.840,
4773.26367,1006.598,5851.83594,241.840,
4773.35547,1006.598,5851.92725,241.840,
4773.44678,1006.598,5852.01855,241.840,
4773.53857,1005.598,5852.11035,241.840,
4773.62988,1006.598,5852.20166,241.840,
4773.72168,1005.598,5852.29346,241.840,
4773.81299,1004.598,5852.38477,242.840,
4773.90430,1004.598,5852.47656,241.840,
4773.99609,1004.598,5852.56787,241.840,
4774.08740,1004.598,5852.65967,241.840,
4774.17920,1003.598,5852.75098,241.840,
4774.27051,1003.598,5852.84229,241.840,
4774.36230,1003.598,5852.93408,240.840,
4774.45361,1003.598,5853.02539,241.840,
4774.54541,1003.598,5853.11719,240.840,
4774.63672,1004.598,5853.20850,240.840,
4774.72803,1003.598,5853.30029,240.840,
4774.81982,1003.598,5853.39160,240.840,
4774.91113,1002.598,5853.48291,240.840,
4775.00293,1003.598,5853.57471,239.840,
4775.09424,1002.598,5853.66602,240.840,
4775.18604,1003.598,5853.75781,240.840,
4775.27734,1002.598,5853.84912,241.840,
4775.36865,1001.598,5853.94092,240.840,
4775.46045,1002.598,5854.03223,240.840,
4775.55176,1002.598,5854.12354,239.840,
4775.64355,1001.598,5854.21533,239.840,
4775.73486,1001.598,5854.30664,239.840,
4775.82666,1001.598,5854.39844,239.840,
4775.91797,1000.598,5854.48975,239.840,
4776.00928,1000.598,5854.58154,238.840,
4776.10107,1000.598,5854.67285,239.840,
4776.19238,999.598,5854.76416,239.840,
4776.28418,999.598,5854.85596,239.840,
4776.37549,999.598,5854.94727,239.840,
4776.46729,999.598,5855.03906,239.840,
4776.55859,998.598,5855.13037,239.840,
4776.65039,998.598,5855.22217,238.840,
4776.74170,998.598,5855.31348,239.840,
4776.83301,998.598,5855.40527,238.840,
4776.92480,998.598,5855.49658,238.840,
4777.01611,998.598,5855.58789,238.840,
4777.10791,998.598,5855.67969,238.840,
4777.19922,998.598,5855.77100,238.840,
4777.29102,997.598,5855.86279,238.840,
4777.38232,998.598,5855.95410,238.840,
4777.47363,997.598,5856.04590,237.840,
4777.56543,998.598,5856.13721,238.840,
4777.65674,997.598,5856.22852,237.840,
4777.74854,998.598,5856.32031,237.840,
4777.83984,998.598,5856.41162,237.840,
4777.93164,998.598,5856.50342,237.840,
4778.02295,998.598,5856.59473,237.840,
4778.11426,999.598,5856.68652,236.840,
4778.20605,1000.598,5856.77783,238.840,
4778.29736,1000.598,5856.86914,237.840,
4778.38916,1000.598,5856.96094,236.840,
4778.48047,1000.598,5857.05225,237.840,
4778.57227,1000.598,5857.14404,236.840,
4778.66357,1000.598,5857.23535,237.840,
4778.75537,1000.598,5857.32715,237.840,
4778.84668,1000.598,5857.41846,236.840,
4778.93799,999.598,5857.51025,236.840,
4779.02979,999.598,5857.60156,236.840,
4779.12109,998.598,5857.69287,236.840,
4779.21289,998.598,5857.78467,236.840,
4779.30420,997.598,5857.87598,236.840,
4779.39600,997.598,5857.96777,236.840,
4779.48730,996.598,5858.05908,236.840,
4779.57861,996.598,5858.15088,236.840,
4779.67041,996.598,5858.24219,236.840,
4779.76172,995.598,5858.33350,236.840,
4779.85352,995.598,5858.42529,235.840,
4779.94482,994.598,5858.51660,235.840,
4780.03662,994.598,5858.60840,235.840,
4780.12793,994.598,5858.69971,235.840,
4780.21924,993.598,5858.79150,235.840,
4780.31104,993.598,5858.88281,235.840,
4780.40234,993.598,5858.97412,235.840,
4780.49414,994.598,5859.06592,235.840,
4780.58545,993.598,5859.15723,235.840,
4780.67725,993.598,5859.24902,235.840,
4780.76855,992.598,5859.34033,235.840,
4780.86035,992.598,5859.43213,235.840,
4780.95166,992.598,5859.52344,235.840,
4781.04297,992.598,5859.61523,234.840,
4781.13477,992.598,5859.70654,235.840,
4781.22607,992.598,5859.79785,234.840,
4781.31787,992.598,5859.88965,234.840,
4781.40918,991.598,5859.98096,234.840,
4781.50098,991.598,5860.07275,234.840,
4781.59229,991.598,5860.16406,234.840,
4781.68359,990.598,5860.25586,233.840,
4781.77539,991.598,5860.34717,234.840,
4781.86670,990.598,5860.43848,233.840,
4781.95850,991.598,5860.53027,233.840,
4782.04980,990.598,5860.62158,233.840,
4782.14160,990.598,5860.71338,234.840,
4782.23291,990.598,5860.80469,233.840,
4782.32422,989.598,5860.89648,233.840,
4782.41602,990.598,5860.98779,233.840,
4782.50732,989.598,5861.07910,233.840,
4782.59912,989.598,5861.17090,233.840,
4782.69043,989.598,5861.26221,233.840,
4782.78223,989.598,5861.35400,233.840,
4782.87354,989.598,5861.44531,233.840,
4782.96484,988.598,5861.53711,233.840,
4783.05664,988.598,5861.62842,233.840,
4783.14795,988.598,5861.72021,233.840,
4783.23975,987.598,5861.81152,232.840,
4783.33105,988.598,5861.90283,232.840,
4783.42285,988.598,5861.99463,232.840,
4783.51416,987.598,5862.08594,231.840,
4783.60596,987.598,5862.17773,231.840,
4783.69727,987.598,5862.26904,232.840,
4783.78857,987.598,5862.36084,232.840,
4783.88037,987.598,5862.45215,232.840,
4783.97168,987.598,5862.54346,233.840,
4784.06348,987.598,5862.63525,234.840,
4784.15479,986.598,5862.72656,234.840,
4784.24658,986.598,5862.81836,234.840,
4784.33789,986.598,5862.90967,235.840,
4784.42920,986.598,5863.00146,235.840,
4784.52100,986.598,5863.09277,235.840,
4784.61230,986.598,5863.18408,235.840,
4784.70410,986.598,5863.27588,234.840,
4784.79541,985.598,5863.36719,234.840,
4784.88721,985.598,5863.45898,234.840,
4784.97852,985.598,5863.55029,233.840,
4785.06982,985.598,5863.64209,233.840,
4785.16162,985.598,5863.73340,233.840,
4785.25293,985.598,5863.82520,232.840,
4785.34473,984.598,5863.91650,231.840,
4785.43604,984.598,5864.00781,232.840,
4785.52783,984.598,5864.09961,232.840,
4785.61914,984.598,5864.19092,231.840,
4785.71094,984.598,5864.28271,231.840,
4785.80225,984.598,5864.37402,230.840,
4785.89355,983.598,5864.46582,230.840,
4785.98535,983.598,5864.55713,229.840,
4786.07666,983.598,5864.64844,230.840,
4786.16846,983.598,5864.74023,229.840,
4786.25977,982.598,5864.83154,228.840,
4786.35156,983.598,5864.92334,227.840,
4786.44287,982.598,5865.01465,227.840,
4786.53418,982.598,5865.10645,225.840,
4786.62598,982.598,5865.19775,225.840,
4786.71729,981.598,5865.28906,225.840,
4786.80908,981.598,5865.38086,225.840,
4786.90039,981.598,5865.47217,224.840,
4786.99219,981.598,5865.56396,224.840,
4787.08350,981.598,5865.65527,225.840,
4787.17480,981.598,5865.74707,225.840,
4787.26660,981.598,5865.83838,225.840,
4787.35791,981.598,5865.93018,225.840,
4787.44971,980.598,5866.02148,226.840,
4787.54102,980.598,5866.11279,226.840,
4787.63281,980.598,5866.20459,226.840,
4787.72412,980.598,5866.29590,226.840,
4787.81592,980.598,5866.38770,226.840,
4787.90723,980.598,5866.47900,226.840,
4787.99854,980.598,5866.57080,227.840,
4788.09033,979.598,5866.66211,227.840,
4788.18164,979.598,5866.75342,227.840,
4788.27344,979.598,5866.84521,227.840,
4788.36475,979.598,5866.93652,227.840,
4788.45654,979.598,5867.02832,228.840,
4788.54785,978.598,5867.11963,227.840,
4788.63916,978.598,5867.21143,227.840,
4788.73096,978.598,5867.30273,227.840,
4788.82227,978.598,5867.39404,227.840,
4788.91406,978.598,5867.48584,227.840,
4789.00537,977.598,5867.57715,226.840,
4789.09717,977.598,5867.66895,227.840,
4789.18848,978.598,5867.76025,227.840,
4789.27979,977.598,5867.85205,226.840,
4789.37158,977.598,5867.94336,227.840,
4789.46289,977.598,5868.03467,227.840,
4789.55469,976.598,5868.12646,226.840,
4789.64600,977.598,5868.21777,226.840,
4789.73779,976.598,5868.30957,226.840,
4789.82910,976.598,5868.40088,226.840,
4789.92090,976.598,5868.49268,227.840,
4790.01221,976.598,5868.58398,226.840,
4790.10352,975.598,5868.67578,226.840,
4790.19531,975.598,5868.76709,226.840,
4790.28662,975.598,5868.85840,226.840,
4790.37842,975.598,5868.95020,226.840,
4790.46973,975.598,5869.04150,226.840,
4790.56152,974.598,5869.13330,225.840,
4790.65283,975.598,5869.22461,225.840,
4790.74414,975.598,5869.31641,225.840,
4790.83594,974.598,5869.40771,225.840,
4790.92725,974.598,5869.49902,225.840,
4791.01904,974.598,5869.59082,225.840,
4791.11035,974.598,5869.68213,225.840,
4791.20215,974.598,5869.77393,225.840,
4791.29346,974.598,5869.86523,225.840,
4791.38477,973.598,5869.95703,225.840,
4791.47656,973.598,5870.04834,224.840,
4791.56787,973.598,5870.13965,225.840,
4791.65967,973.598,5870.23145,225.840,
4791.75098,972.598,5870.32275,224.840,
4791.84277,972.598,5870.41455,225.840,
4791.93408,972.598,5870.50586,225.840,
4792.02588,972.598,5870.59766,224.840,
4792.11719,972.598,5870.68896,224.840,
4792.20850,973.598,5870.78076,224.840,
4792.30029,972.598,5870.87207,224.840,
4792.39160,972.598,5870.96338,223.840,
4792.48340,971.598,5871.05518,224.840,
4792.57471,971.598,5871.14648,223.840,
4792.66650,971.598,5871.23828,224.840,
4792.75781,972.598,5871.32959,223.840,
4792.84912,971.598,5871.42139,224.840,
4792.94092,971.598,5871.51270,223.840,
4793.03223,970.598,5871.60400,223.840,
4793.12402,971.598,5871.69580,223.840,
4793.21533,970.598,5871.78711,223.840,
4793.30713,970.598,5871.87891,223.840,
4793.39844,970.598,5871.97021,224.840,
4793.48975,970.598,5872.06201,223.840,
4793.58154,969.598,5872.15332,223.840,
4793.67285,970.598,5872.24463,223.840,
4793.76465,969.598,5872.33643,223.840,
4793.85596,969.598,5872.42773,223.840,
4793.94775,969.598,5872.51953,222.840,
4794.03906,969.598,5872.61084,223.840,
4794.13086,968.598,5872.70264,222.840,
4794.22217,969.598,5872.79395,222.840,
4794.31348,968.598,5872.88574,223.840,
4794.40527,968.598,5872.97705,223.840,
4794.49658,968.598,5873.06836,222.840,
4794.58838,969.598,5873.16016,222.840,
4794.67969,969.598,5873.25146,222.840,
4794.77148,969.598,5873.34326,221.840,
4794.86279,969.598,5873.43457,222.840,
4794.95410,969.598,5873.52637,222.840,
4795.04590,969.598,5873.61768,221.840,
4795.13721,970.598,5873.70898,221.840,
4795.22900,969.598,5873.80078,222.840,
4795.32031,968.598,5873.89209,221.840,
4795.41211,968.598,5873.98389,221.840,
4795.50342,968.598,5874.07520,221.840,
4795.59473,968.598,5874.16699,222.840,
4795.68652,966.598,5874.25830,221.840,
4795.77783,967.598,5874.34961,222.840,
4795.86963,966.598,5874.44141,221.840,
4795.96094,966.598,5874.53271,221.840,
4796.05273,966.598,5874.62451,221.840,
4796.14404,966.598,5874.71582,221.840,
4796.23535,965.598,5874.80762,221.840,
4796.32715,965.598,5874.89893,221.840,
4796.41846,965.598,5874.99072,221.840,
4796.51025,965.598,5875.08203,220.840,
4796.60156,965.598,5875.17334,220.840,
4796.69336,965.598,5875.26514,220.840,
4796.78467,963.598,5875.35645,220.840,
4796.87646,963.598,5875.44824,220.840,
4796.96777,962.598,5875.53955,220.840,
4797.05908,961.598,5875.63135,219.840,
4797.15088,961.598,5875.72266,219.840,
4797.24219,960.598,5875.81396,220.840,
4797.33398,960.598,5875.90576,220.840,
4797.42529,958.598,5875.99707,220.840,
4797.51709,959.598,5876.08887,219.840,
4797.60840,959.598,5876.18018,219.840,
4797.69971,959.598,5876.27197,219.840,
4797.79150,959.598,5876.36328,219.840,
4797.88281,959.598,5876.45459,219.840,
4797.97461,959.598,5876.54639,219.840,
4798.06592,959.598,5876.63770,219.840,
4798.15771,959.598,5876.72949,219.840,
4798.24902,959.598,5876.82080,218.840,
4798.34033,960.598,5876.91260,218.840,
4798.43213,959.598,5877.00391,218.840,
4798.52344,959.598,5877.09570,218.840,
4798.61523,960.598,5877.18701,218.840,
4798.70654,959.598,5877.27832,219.840,
4798.79834,960.598,5877.37012,218.840,
4798.88965,960.598,5877.46143,218.840,
4798.98145,959.598,5877.55322,218.840,
4799.07275,959.598,5877.64453,217.840,
4799.16406,959.598,5877.73633,217.840,
4799.25586,959.598,5877.82764,217.840,
4799.34717,959.598,5877.91895,217.840,
4799.43896,959.598,5878.01074,217.840,
4799.53027,960.598,5878.10205,218.840,
4799.62207,959.598,5878.19385,217.840,
4799.71338,959.598,5878.28516,217.840,
4799.80469,959.598,5878.37695,217.840,
4799.89648,959.598,5878.46826,217.840,
4799.98779,958.598,5878.55957,217.840,
4800.07959,959.598,5878.65137,217.840,
4800.17090,958.598,5878.74268,217.840,
4800.26270,958.598,5878.83447,217.840,
4800.35400,958.598,5878.92578,217.840,
4800.44531,957.598,5879.01758,216.840,
4800.53711,957.598,5879.10889,217.840,
4800.62842,957.598,5879.20068,216.840,
4800.72021,957.598,5879.29199,216.840,
4800.81152,957.598,5879.38330,216.840,
4800.90332,957.598,5879.47510,216.840,
4800.99463,957.598,5879.56641,216.840,
4801.08643,956.598,5879.65820,216.840,
4801.17773,956.598,5879.74951,216.840,
4801.26904,956.598,5879.84131,215.840,
4801.36084,956.598,5879.93262,215.840,
4801.45215,955.598,5880.02393,215.840,
4801.54395,956.598,5880.11572,214.840,
4801.63525,956.598,5880.20703,215.840,
4801.72705,955.598,5880.29883,214.840,
4801.81836,955.598,5880.39014,213.840,
4801.90967,955.598,5880.48193,213.840,
4802.00146,955.598,5880.57324,213.840,
4802.09277,955.598,5880.66455,212.840,
4802.18457,955.598,5880.75635,212.840,
4802.27588,954.598,5880.84766,212.840,
4802.36768,954.598,5880.93945,213.840,
4802.45898,954.598,5881.03076,212.840,
4802.55029,954.598,5881.12256,213.840,
4802.64209,953.598,5881.21387,213.840,
4802.73340,954.598,5881.30518,213.840,
4802.82520,954.598,5881.39697,212.840,
4802.91650,953.598,5881.48828,213.840,
4803.00830,953.598,5881.58008,213.840,
4803.09961,953.598,5881.67139,213.840,
4803.19141,953.598,5881.76318,213.840,
4803.28271,952.598,5881.85449,213.840,
4803.37402,952.598,5881.94629,213.840,
4803.46582,952.598,5882.03760,213.840,
4803.55713,952.598,5882.12891,213.840,
4803.64893,952.598,5882.22070,213.840,
4803.74023,952.598,5882.31201,214.840,
4803.83203,951.598,5882.40381,215.840,
4803.92334,953.598,5882.49512,215.840,
4804.01465,951.598,5882.58691,215.840,
4804.10645,951.598,5882.67822,216.840,
4804.19775,951.598,5882.76953,216.840,
4804.28955,951.598,5882.86133,216.840,
4804.38086,951.598,5882.95264,216.840,
4804.47266,950.598,5883.04443,217.840,
4804.56396,951.598,5883.13574,217.840,
4804.65527,950.598,5883.22754,216.840,
4804.74707,950.598,5883.31885,216.840,
4804.83838,950.598,5883.41016,215.840,
4804.93018,950.598,5883.50195,216.840,
4805.02148,950.598,5883.59326,215.840,
4805.11328,949.598,5883.68506,215.840,
4805.20459,949.598,5883.77637,215.840,
4805.29639,949.598,5883.86816,214.840,
4805.38770,949.598,5883.95947,214.840,
4805.47900,949.598,5884.05127,213.840,
4805.57080,949.598,5884.14258,213.840,
4805.66211,949.598,5884.23389,213.840,
4805.75391,949.598,5884.32568,213.840,
4805.84521,948.598,5884.41699,212.840,
4805.93701,949.598,5884.50879,212.840,
4806.02832,948.598,5884.60010,213.840,
4806.11963,948.598,5884.69189,211.840,
4806.21143,947.598,5884.78320,212.840,
4806.30273,947.598,5884.87451,211.840,
4806.39453,947.598,5884.96631,212.840,
4806.48584,947.598,5885.05762,211.840,
4806.57764,947.598,5885.14941,211.840,
4806.66895,947.598,5885.24072,211.840,
4806.76025,947.598,5885.33252,211.840,
4806.85205,947.598,5885.42383,211.840,
4806.94336,946.598,5885.51514,211.840,
4807.03516,946.598,5885.60693,210.840,
4807.12646,946.598,5885.69824,210.840,
4807.21826,946.598,5885.79004,210.840,
4807.30957,946.598,5885.88135,210.840,
4807.40088,946.598,5885.97314,210.840,
4807.49268,946.598,5886.06445,211.840,
4807.58398,945.598,5886.15625,210.840,
4807.67578,945.598,5886.24756,210.840,
4807.76709,945.598,5886.33887,210.840,
4807.85889,945.598,5886.43066,210.840,
4807.95020,945.598,5886.52197,209.840,
4808.04199,945.598,5886.61377,210.840,
4808.13330,944.598,5886.70508,210.840,
4808.22461,945.598,5886.79688,209.840,
4808.31641,945.598,5886.88818,209.840,
4808.40771,944.598,5886.97949,209.840,
4808.49951,944.598,5887.07129,209.840,
4808.59082,944.598,5887.16260,209.840,
4808.68262,944.598,5887.25439,209.840,
4808.77393,943.598,5887.34570,209.840,
4808.86523,943.598,5887.43750,209.840,
4808.95703,943.598,5887.52881,209.840,
4809.04834,943.598,5887.62012,209.840,
4809.14014,943.598,5887.71191,209.840,
4809.23145,943.598,5887.80322,209.840,
4809.32324,942.598,5887.89502,208.840,
4809.41455,942.598,5887.98633,209.840,
4809.50586,942.598,5888.07813,208.840,
4809.59766,942.598,5888.16943,208.840,
4809.68896,941.598,5888.26123,208.840,
4809.78076,942.598,5888.35254,208.840,
4809.87207,941.598,5888.44385,208.840,
4809.96387,941.598,5888.53564,208.840,
4810.05518,941.598,5888.62695,208.840,
4810.14697,941.598,5888.71875,208.840,
4810.23828,941.598,5888.81006,208.840,
4810.32959,941.598,5888.90186,208.840,
4810.42139,941.598,5888.99316,208.840,
4810.51270,941.598,5889.08447,208.840,
4810.60449,940.598,5889.17627,208.840,
4810.69580,940.598,5889.26758,207.840,
4810.78760,940.598,5889.35938,208.840,
4810.87891,940.598,5889.45068,208.840,
4810.97021,940.598,5889.54248,207.840,
4811.06201,939.598,5889.63379,207.840,
4811.15332,939.598,5889.72510,208.840,
4811.24512,940.598,5889.81689,207.840,
4811.33643,939.598,5889.90820,207.840,
4811.42822,939.598,5890.00000,207.840,
4811.51953,939.598,5890.09131,207.840,
4811.61084,939.598,5890.18311,206.840,
4811.70264,938.598,5890.27441,207.840,
4811.79395,938.598,5890.36621,207.840,
4811.88574,938.598,5890.45752,206.840,
4811.97705,938.598,5890.54883,206.840,
4812.06885,937.598,5890.64063,206.840,
4812.16016,938.598,5890.73193,206.840,
4812.25195,938.598,5890.82373,206.840,
4812.34326,937.598,5890.91504,205.840,
4812.43457,937.598,5891.00684,206.840,
4812.52637,937.598,5891.09814,205.840,
4812.61768,937.598,5891.18945,205.840,
4812.70947,937.598,5891.28125,206.840,
4812.80078,937.598,5891.37256,205.840,
4812.89258,937.598,5891.46436,205.840,
4812.98389,937.598,5891.55566,205.840,
4813.07520,938.598,5891.64746,205.840,
4813.16699,938.598,5891.73877,205.840,
4813.25830,939.598,5891.83008,206.840,
4813.35010,939.598,5891.92188,205.840,
4813.44141,939.598,5892.01318,205.840,
4813.53320,939.598,5892.10498,205.840,
4813.62451,939.598,5892.19629,205.840,
4813.71582,939.598,5892.28809,205.840,
4813.80762,938.598,5892.37939,204.840,
4813.89893,938.598,5892.47070,204.840,
4813.99072,938.598,5892.56250,204.840,
4814.08203,938.598,5892.65381,204.840,
4814.17383,937.598,5892.74561,204.840,
4814.26514,936.598,5892.83691,204.840,
4814.35693,936.598,5892.92871,204.840,
4814.44824,935.598,5893.02002,203.840,
4814.53955,935.598,5893.11182,204.840,
4814.63135,935.598,5893.20313,203.840,
4814.72266,934.598,5893.29443,204.840,
4814.81445,934.598,5893.38623,204.840,
4814.90576,934.598,5893.47754,203.840,
4814.99756,934.598,5893.56934,204.840,
4815.08887,933.598,5893.66064,203.840,
4815.18018,933.598,5893.75244,204.840,
4815.27197,933.598,5893.84375,203.840,
4815.36328,933.598,5893.93506,203.840,
4815.45508,932.598,5894.02686,204.840,
4815.54639,932.598,5894.11816,203.840,
4815.63818,931.598,5894.20996,203.840,
4815.72949,931.598,5894.30127,203.840,
4815.82080,931.598,5894.39307,203.840,
4815.91260,930.598,5894.48438,203.840,
4816.00391,930.598,5894.57568,203.840,
4816.09570,929.598,5894.66748,203.840,
4816.18701,930.598,5894.75879,202.840,
4816.27881,930.598,5894.85059,203.840,
4816.37012,930.598,5894.94189,202.840,
4816.46191,929.598,5895.03369,202.840,
4816.55322,929.598,5895.12500,202.840,
4816.64453,929.598,5895.21680,201.840,
4816.73633,930.598,5895.30811,202.840,
4816.82764,929.598,5895.39941,202.840,
4816.91943,929.598,5895.49121,202.840,
4817.01074,930.598,5895.58252,202.840,
4817.10254,930.598,5895.67432,201.840,
4817.19385,929.598,5895.76563,202.840,
4817.28516,929.598,5895.85742,201.840,
4817.37695,929.598,5895.94873,201.840,
4817.46826,929.598,5896.04004,201.840,
4817.56006,929.598,5896.13184,201.840,
4817.65137,929.598,5896.22314,201.840,
4817.74316,928.598,5896.31494,201.840,
4817.83447,928.598,5896.40625,201.840,
4817.92578,928.598,5896.49805,201.840,
4818.01758,928.598,5896.58936,201.840,
4818.10889,928.598,5896.68066,201.840,
4818.20068,927.598,5896.77246,201.840,
4818.29199,928.598,5896.86377,201.840,
4818.38379,927.598,5896.95557,201.840,
4818.47510,927.598,5897.04688,201.840,
4818.56689,928.598,5897.13867,201.840,
4818.65820,926.598,5897.22998,200.840,
4818.74951,927.598,5897.32178,200.840,
4818.84131,927.598,5897.41309,200.840,
4818.93262,927.598,5897.50439,200.840,
4819.02441,926.598,5897.59619,200.840,
4819.11572,926.598,5897.68750,199.840,
4819.20752,926.598,5897.77930,199.840,
4819.29883,926.598,5897.87061,197.840,
4819.39014,926.598,5897.96240,197.840,
4819.48193,926.598,5898.05371,196.840,
4819.57324,926.598,5898.14502,196.840,
4819.66504,925.598,5898.23682,196.840,
4819.75635,925.598,5898.32813,196.840,
4819.84814,925.598,5898.41992,196.840,
4819.93945,925.598,5898.51123,195.840,
4820.03076,925.598,5898.60303,196.840,
4820.12256,925.598,5898.69434,196.840,
4820.21387,924.598,5898.78564,197.840,
4820.30566,924.598,5898.87744,197.840,
4820.39697,924.598,5898.96875,197.840,
4820.48877,924.598,5899.06055,197.840,
4820.58008,924.598,5899.15186,197.840,
4820.67139,924.598,5899.24365,199.840,
4820.76318,924.598,5899.33496,197.840,
4820.85449,923.598,5899.42676,198.840,
4820.94629,923.598,5899.51807,198.840,
4821.03760,923.598,5899.60938,198.840,
4821.12939,923.598,5899.70117,198.840,
4821.22070,922.598,5899.79248,198.840,
4821.31250,923.598,5899.88428,199.840,
4821.40381,923.598,5899.97559,198.840,
4821.49512,923.598,5900.06738,198.840,
4821.58691,922.598,5900.15869,199.840,
4821.67822,922.598,5900.25000,199.840,
4821.77002,922.598,5900.34180,200.840,
4821.86133,922.598,5900.43311,201.840,
4821.95313,922.598,5900.52490,200.840,
4822.04443,922.598,5900.61621,201.840,
4822.13574,921.598,5900.70801,202.840,
4822.22754,921.598,5900.79932,201.840,
4822.31885,921.598,5900.89063,201.840,
4822.41064,920.598,5900.98242,201.840,
4822.50195,921.598,5901.07373,201.840,
4822.59375,920.598,5901.16553,200.840,
4822.68506,920.598,5901.25684,200.840,
4822.77637,919.598,5901.34863,200.840,
4822.86816,920.598,5901.43994,199.840,
4822.95947,920.598,5901.53174,199.840,
4823.05127,919.598,5901.62305,198.840,
4823.14258,919.598,5901.71436,198.840,
4823.23438,919.598,5901.80615,198.840,
4823.32568,919.598,5901.89746,197.840,
4823.41748,919.598,5901.98926,197.840,
4823.50879,919.598,5902.08057,197.840,
4823.60010,919.598,5902.17236,197.840,
4823.69189,919.598,5902.26367,197.840,
4823.78320,918.598,5902.35498,196.840,
4823.87500,918.598,5902.44678,196.840,
4823.96631,918.598,5902.53809,196.840,
4824.05811,918.598,5902.62988,196.840,
4824.14941,918.598,5902.72119,196.840,
4824.24072,918.598,5902.81299,196.840,
4824.33252,918.598,5902.90430,196.840,
4824.42383,918.598,5902.99561,196.840,
4824.51563,917.598,5903.08740,195.840,
4824.60693,918.598,5903.17871,195.840,
4824.69873,917.598,5903.27051,196.840,
4824.79004,917.598,5903.36182,195.840,
4824.88135,917.598,5903.45361,195.840,
4824.97314,917.598,5903.54492,196.840,
4825.06445,917.598,5903.63672,196.840,
4825.15625,917.598,5903.72803,195.840,
4825.24756,916.598,5903.81934,195.840,
4825.33936,916.598,5903.91113,195.840,
4825.43066,916.598,5904.00244,195.840,
4825.52246,916.598,5904.09424,195.840,
4825.61377,916.598,5904.18555,195.840,
4825.70508,916.598,5904.27734,195.840,
4825.79688,916.598,5904.36865,194.840,
4825.88818,916.598,5904.45996,194.840,
4825.97998,916.598,5904.55176,194.840,
4826.07129,915.598,5904.64307,195.840,
4826.16309,916.598,5904.73486,195.840,
4826.25439,915.598,5904.82617,194.840,
4826.34570,915.598,5904.91797,195.840,
4826.43750,915.598,5905.00928,194.840,
4826.52881,915.598,5905.10059,195.840,
4826.62061,914.598,5905.19238,194.840,
4826.71191,914.598,5905.28369,194.840,
4826.80371,914.598,5905.37549,194.840,
4826.89502,914.598,5905.46680,194.840,
4826.98633,913.598,5905.55859,194.840,
4827.07813,914.598,5905.64990,194.840,
4827.16943,914.598,5905.74121,194.840,
4827.26123,913.598,5905.83301,193.840,
4827.35254,914.598,5905.92432,194.840,
4827.44434,913.598,5906.01611,194.840,
4827.53564,913.598,5906.10742,193.840,
4827.62744,913.598,5906.19922,193.840,
4827.71875,913.598,5906.29053,194.840,
4827.81006,912.598,5906.38232,193.840,
4827.90186,912.598,5906.47363,193.840,
4827.99316,912.598,5906.56494,193.840,
4828.08496,911.598,5906.65674,193.840,
4828.17627,911.598,5906.74805,193.840,
4828.26807,911.598,5906.83984,193.840,
4828.35938,911.598,5906.93115,193.840,
4828.45068,911.598,5907.02295,192.840,
4828.54248,911.598,5907.11426,193.840,
4828.63379,911.598,5907.20557,193.840,
4828.72559,911.598,5907.29736,192.840,
4828.81689,911.598,5907.38867,192.840,
4828.90869,911.598,5907.48047,192.840,
4829.00000,910.598,5907.57178,192.840,
4829.09131,910.598,5907.66357,192.840,
4829.18311,910.598,5907.75488,192.840,
4829.27441,910.598,5907.84619,193.840,
4829.36621,910.598,5907.93799,192.840,
4829.45752,910.598,5908.02930,191.840,
4829.54932,909.598,5908.12109,191.840,
4829.64063,909.598,5908.21240,191.840,
4829.73242,909.598,5908.30420,191.840,
4829.82373,909.598,5908.39551,192.840,
4829.91504,909.598,5908.48730,191.840,
4830.00684,908.598,5908.57861,191.840,
4830.09814,909.598,5908.66992,191.840,
4830.18994,909.598,5908.76172,191.840,
4830.28125,909.598,5908.85303,191.840,
4830.37305,908.598,5908.94482,191.840,
4830.46436,908.598,5909.03613,191.840,
4830.55566,908.598,5909.12793,191.840,
4830.64746,908.598,5909.21924,190.840,
4830.73877,908.598,5909.31055,191.840,
4830.83057,907.598,5909.40234,191.840,
4830.92188,907.598,5909.49365,191.840,
4831.01367,907.598,5909.58545,191.840,
4831.10498,907.598,5909.67676,191.840,
4831.19629,907.598,5909.76855,190.840,
4831.28809,907.598,5909.85986,190.840,
4831.37939,907.598,5909.95117,191.840,
4831.47119,906.598,5910.04297,190.840,
4831.56250,906.598,5910.13428,190.840,
4831.65430,906.598,5910.22607,190.840,
4831.74561,907.598,5910.31738,190.840,
4831.83740,906.598,5910.40918,190.840,
4831.92871,907.598,5910.50049,190.840,
4832.02002,906.598,5910.59229,190.840,
4832.11182,906.598,5910.68359,189.840,
4832.20313,906.598,5910.77490,190.840,
4832.29492,906.598,5910.86670,190.840,
4832.38623,905.598,5910.95801,190.840,
4832.47803,905.598,5911.04980,189.840,
4832.56934,905.598,5911.14111,189.840,
4832.66064,905.598,5911.23291,189.840,
4832.75244,905.598,5911.32422,189.840,
4832.84375,905.598,5911.41553,189.840,
4832.93555,904.598,5911.50732,189.840,
4833.02686,905.598,5911.59863,189.840,
4833.11865,904.598,5911.69043,189.840,
4833.20996,905.598,5911.78174,189.840,
4833.30127,904.598,5911.87354,189.840,
4833.39307,904.598,5911.96484,188.840,
4833.48438,904.598,5912.05615,189.840,
4833.57617,903.598,5912.14795,189.840,
4833.66748,903.598,5912.23926,189.840,
4833.75928,904.598,5912.33105,188.840,
4833.85059,903.598,5912.42236,189.840,
4833.94189,903.598,5912.51416,189.840,
4834.03369,902.598,5912.60547,188.840,
4834.12500,902.598,5912.69727,188.840,
4834.21680,901.598,5912.78857,188.840,
4834.30811,901.598,5912.87988,188.840,
4834.39990,900.598,5912.97168,188.840,
4834.49121,899.598,5913.06299,188.840,
4834.58301,898.598,5913.15479,188.840,
4834.67432,898.598,5913.24609,188.840,
4834.76563,897.598,5913.33789,188.840,
4834.85742,897.598,5913.42920,187.840,
4834.94873,898.598,5913.52051,188.840,
4835.04053,897.598,5913.61230,187.840,
4835.13184,897.598,5913.70361,188.840,
4835.22363,897.598,5913.79541,187.840,
4835.31494,898.598,5913.88672,188.840,
4835.40625,898.598,5913.97852,187.840,
4835.49805,898.598,5914.06982,187.840,
4835.58936,898.598,5914.16113,187.840,
4835.68115,899.598,5914.25293,187.840,
4835.77246,898.598,5914.34424,187.840,
4835.86426,899.598,5914.43604,187.840,
4835.95557,899.598,5914.52734,187.840,
4836.04688,899.598,5914.61914,186.840,
4836.13867,900.598,5914.71045,187.840,
4836.22998,899.598,5914.80225,187.840,
4836.32178,899.598,5914.89355,186.840,
4836.41309,899.598,5914.98486,186.840,
4836.50488,899.598,5915.07666,186.840,
4836.59619,898.598,5915.16797,186.840,
4836.68799,899.598,5915.25977,185.840,
4836.77930,899.598,5915.35107,185.840,
4836.87061,898.598,5915.44287,184.840,
4836.96240,898.598,5915.53418,184.840,
4837.05371,898.598,5915.62549,183.840,
4837.14551,898.598,5915.71729,184.840,
4837.23682,898.598,5915.80859,184.840,
4837.32861,898.598,5915.90039,184.840,
4837.41992,897.598,5915.99170,183.840,
4837.51123,897.598,5916.08350,184.840,
4837.60303,898.598,5916.17480,184.840,
4837.69434,897.598,5916.26611,184.840,
4837.78613,897.598,5916.35791,184.840,
4837.87744,897.598,5916.44922,184.840,
4837.96924,897.598,5916.54102,184.840,
4838.06055,896.598,5916.63232,185.840,
4838.15186,896.598,5916.72412,184.840,
4838.24365,896.598,5916.81543,185.840,
4838.33496,896.598,5916.90674,185.840,
4838.42676,896.598,5916.99854,184.840,
4838.51807,896.598,5917.08984,185.840,
4838.60986,895.598,5917.18164,184.840,
4838.70117,895.598,5917.27295,184.840,
4838.79297,895.598,5917.36475,185.840,
4838.88428,895.598,5917.45605,184.840,
4838.97559,895.598,5917.54785,185.840,
4839.06738,895.598,5917.63916,185.840,
4839.15869,895.598,5917.73047,185.840,
4839.25049,894.598,5917.82227,185.840,
4839.34180,895.598,5917.91357,186.840,
4839.43359,894.598,5918.00537,186.840,
4839.52490,894.598,5918.09668,185.840,
4839.61621,894.598,5918.18848,186.840,
4839.70801,894.598,5918.27979,187.840,
4839.79932,894.598,5918.37109,185.840,
4839.89111,893.598,5918.46289,186.840,
4839.98242,893.598,5918.55420,186.840,
4840.07422,893.598,5918.64600,185.840,
4840.16553,893.598,5918.73730,185.840,
4840.25684,892.598,5918.82910,185.840,
4840.34863,893.598,5918.92041,185.840,
4840.43994,892.598,5919.01172,185.840,
4840.53174,893.598,5919.10352,185.840,
4840.62305,892.598,5919.19482,184.840,
4840.71484,892.598,5919.28662,183.840,
4840.80615,892.598,5919.37793,184.840,
4840.89795,891.598,5919.46973,183.840,
4840.98926,892.598,5919.56104,183.840,
4841.08057,891.598,5919.65283,183.840,
4841.17236,891.598,5919.74414,184.840,
4841.26367,891.598,5919.83545,183.840,
4841.35547,891.598,5919.92725,183.840,
4841.44678,891.598,5920.01855,183.840,
4841.53857,891.598,5920.11035,182.840,
4841.62988,890.598,5920.20166,183.840,
4841.72119,891.598,5920.29346,182.840,
4841.81299,891.598,5920.38477,182.840,
4841.90430,890.598,5920.47607,182.840,
4841.99609,890.598,5920.56787,182.840,
4842.08740,890.598,5920.65918,182.840,
4842.17920,890.598,5920.75098,181.840,
4842.27051,890.598,5920.84229,182.840,
4842.36182,890.598,5920.93408,181.840,
4842.45361,889.598,5921.02539,181.840,
4842.54492,889.598,5921.11670,182.840,
4842.63672,889.598,5921.20850,182.840,
4842.72803,889.598,5921.29980,182.840,
4842.81982,889.598,5921.39160,182.840,
4842.91113,888.598,5921.48291,181.840,
4843.00293,887.598,5921.57471,182.840,
4843.09424,888.598,5921.66602,182.840,
4843.18555,888.598,5921.75781,181.840,
4843.27734,887.598,5921.84912,181.840,
4843.36865,888.598,5921.94043,182.840,
4843.46045,888.598,5922.03223,181.840,
4843.55176,887.598,5922.12354,181.840,
4843.64355,887.598,5922.21533,181.840,
4843.73486,888.598,5922.30664,181.840,
4843.82617,887.598,5922.39844,181.840,
4843.91797,887.598,5922.48975,181.840,
4844.00928,887.598,5922.58105,181.840,
4844.10107,887.598,5922.67285,181.840,
4844.19238,887.598,5922.76416,180.840,
4844.28418,886.598,5922.85596,180.840,
4844.37549,886.598,5922.94727,180.840,
4844.46680,886.598,5923.03906,180.840,
4844.55859,886.598,5923.13037,180.840,
4844.64990,886.598,5923.22168,180.840,
4844.74170,886.598,5923.31348,180.840,
4844.83301,886.598,5923.40479,180.840,
4844.92480,887.598,5923.49658,180.840,
4845.01611,886.598,5923.58789,180.840,
4845.10742,885.598,5923.67969,179.840,
4845.19922,885.598,5923.77100,179.840,
4845.29053,885.598,5923.86279,179.840,
4845.38232,886.598,5923.95410,179.840,
4845.47363,885.598,5924.04541,179.840,
4845.56543,885.598,5924.13721,180.840,
4845.65674,885.598,5924.22852,179.840,
4845.74854,884.598,5924.32031,179.840,
4845.83984,884.598,5924.41162,179.840,
4845.93115,885.598,5924.50342,179.840,
4846.02295,883.598,5924.59473,179.840,
4846.11426,884.598,5924.68604,179.840,
4846.20605,884.598,5924.77783,179.840,
4846.29736,884.598,5924.86914,179.840,
4846.38916,884.598,5924.96094,179.840,
4846.48047,883.598,5925.05225,178.840,
4846.57178,883.598,5925.14404,178.840,
4846.66357,883.598,5925.23535,178.840,
4846.75488,883.598,5925.32666,178.840,
4846.84668,883.598,5925.41846,178.840,
4846.93799,883.598,5925.50977,178.840,
4847.02979,883.598,5925.60156,179.840,
4847.12109,883.598,5925.69287,178.840,
4847.21240,882.598,5925.78467,177.840,
4847.30420,882.598,5925.87598,177.840,
4847.39551,882.598,5925.96777,177.840,
4847.48730,882.598,5926.05908,177.840,
4847.57861,882.598,5926.15039,178.840,
4847.67041,882.598,5926.24219,178.840,
4847.76172,882.598,5926.33350,177.840,
4847.85352,882.598,5926.42529,177.840,
4847.94482,881.598,5926.51660,177.840,
4848.03613,882.598,5926.60840,177.840,
4848.12793,881.598,5926.69971,177.840,
4848.21924,881.598,5926.79102,177.840,
4848.31104,881.598,5926.88281,177.840,
4848.40234,881.598,5926.97412,177.840,
4848.49414,880.598,5927.06592,177.840,
4848.58545,880.598,5927.15723,177.840,
4848.67676,880.598,5927.24902,177.840,
4848.76855,879.598,5927.34033,177.840,
4848.85986,880.598,5927.43164,177.840,
4848.95166,880.598,5927.52344,177.840,
4849.04297,880.598,5927.61475,176.840,
4849.13477,879.598,5927.70654,177.840,
4849.22607,879.598,5927.79785,177.840,
4849.31738,880.598,5927.88965,176.840,
4849.40918,880.598,5927.98096,176.840,
4849.50049,879.598,5928.07275,176.840,
4849.59229,879.598,5928.16406,176.840,
4849.68359,878.598,5928.25537,176.840,
4849.77539,878.598,5928.34717,176.840,
4849.86670,879.598,5928.43848,176.840,
4849.95850,878.598,5928.53027,176.840,
4850.04980,878.598,5928.62158,176.840,
4850.14111,878.598,5928.71338,176.840,
4850.23291,877.598,5928.80469,175.840,
4850.32422,877.598,5928.89600,176.840,
4850.41602,877.598,5928.98779,175.840,
4850.50732,877.598,5929.07910,175.840,
4850.59912,876.598,5929.17090,175.840,
4850.69043,876.598,5929.26221,176.840,
4850.78174,876.598,5929.35400,175.840,
4850.87354,875.598,5929.44531,175.840,
4850.96484,873.598,5929.53662,175.840,
4851.05664,873.598,5929.62842,175.840,
4851.14795,873.598,5929.71973,174.840,
4851.23975,873.598,5929.81152,175.840,
4851.33105,872.598,5929.90283,175.840,
4851.42236,872.598,5929.99463,175.840,
4851.51416,873.598,5930.08594,174.840,
4851.60547,872.598,5930.17725,175.840,
4851.69727,873.598,5930.26904,174.840,
4851.78857,873.598,5930.36035,174.840,
4851.88037,873.598,5930.45215,174.840,
4851.97168,873.598,5930.54346,174.840,
4852.06348,873.598,5930.63525,174.840,
4852.15479,874.598,5930.72656,174.840,
4852.24609,874.598,5930.81836,174.840,
4852.33789,874.598,5930.90967,174.840,
4852.42920,874.598,5931.00098,173.840,
4852.52100,874.598,5931.09277,174.840,
4852.61230,874.598,5931.18408,173.840,
4852.70410,874.598,5931.27588,173.840,
4852.79541,874.598,5931.36719,174.840,
4852.88672,874.598,5931.45898,174.840,
4852.97852,873.598,5931.55029,173.840,
4853.06982,873.598,5931.64160,173.840,
4853.16162,872.598,5931.73340,173.840,
4853.25293,872.598,5931.82471,173.840,
4853.34473,871.598,5931.91650,173.840,
4853.43604,871.598,5932.00781,173.840,
4853.52734,871.598,5932.09961,173.840,
4853.61914,871.598,5932.19092,173.840,
4853.71045,872.598,5932.28223,173.840,
4853.80225,871.598,5932.37402,173.840,
4853.89355,872.598,5932.46533,173.840,
4853.98535,871.598,5932.55713,172.840,
4854.07666,871.598,5932.64844,173.840,
4854.16846,872.598,5932.74023,173.840,
4854.25977,871.598,5932.83154,173.840,
4854.35107,871.598,5932.92334,175.840,
4854.44287,871.598,5933.01465,175.840,
4854.53418,871.598,5933.10596,175.840,
4854.62598,871.598,5933.19775,176.840,
4854.71729,871.598,5933.28906,176.840,
4854.80908,871.598,5933.38086,176.840,
4854.90039,871.598,5933.47217,176.840,
4854.99170,870.598,5933.56396,176.840,
4855.08350,871.598,5933.65527,176.840,
4855.17480,871.598,5933.74658,175.840,
4855.26660,870.598,5933.83838,175.840,
4855.35791,870.598,5933.92969,175.840,
4855.44971,870.598,5934.02148,174.840,
4855.54102,870.598,5934.11279,174.840,
4855.63232,870.598,5934.20459,173.840,
4855.72412,870.598,5934.29590,173.840,
4855.81543,869.598,5934.38721,173.840,
4855.90723,870.598,5934.47900,173.840,
4855.99854,869.598,5934.57031,172.840,
4856.09033,869.598,5934.66211,172.840,
4856.18164,869.598,5934.75342,172.840,
4856.27344,869.598,5934.84521,171.840,
4856.36475,869.598,5934.93652,171.840,
4856.45605,869.598,5935.02832,171.840,
4856.54785,869.598,5935.11963,171.840,
4856.63916,869.598,5935.21094,170.840,
4856.73096,868.598,5935.30273,169.840,
4856.82227,868.598,5935.39404,168.840,
4856.91406,868.598,5935.48584,167.840,
4857.00537,868.598,5935.57715,166.840,
4857.09668,868.598,5935.66895,166.840,
4857.18848,867.598,5935.76025,165.840,
4857.27979,867.598,5935.85156,166.840,
4857.37158,867.598,5935.94336,165.840,
4857.46289,867.598,5936.03467,165.840,
4857.55469,866.598,5936.12646,166.840,
4857.64600,866.598,5936.21777,167.840,
4857.73730,866.598,5936.30957,167.840,
4857.82910,866.598,5936.40088,167.840,
4857.92041,866.598,5936.49219,167.840,
4858.01221,866.598,5936.58398,167.840,
4858.10352,866.598,5936.67529,167.840,
4858.19531,866.598,5936.76709,167.840,
4858.28662,865.598,5936.85840,168.840,
4858.37793,865.598,5936.95020,168.840,
4858.46973,865.598,5937.04150,168.840,
4858.56104,865.598,5937.13330,168.840,
4858.65283,865.598,5937.22461,169.840,
4858.74414,865.598,5937.31592,169.840,
4858.83594,865.598,5937.40771,169.840,
4858.92725,865.598,5937.49902,169.840,
4859.01904,865.598,5937.59082,169.840,
4859.11035,864.598,5937.68213,169.840,
4859.20166,864.598,5937.77393,169.840,
4859.29346,865.598,5937.86523,169.840,
4859.38477,864.598,5937.95654,169.840,
4859.47656,864.598,5938.04834,169.840,
4859.56787,865.598,5938.13965,169.840,
4859.65967,864.598,5938.23145,169.840,
4859.75098,864.598,5938.32275,168.840,
4859.84229,864.598,5938.41455,168.840,
4859.93408,864.598,5938.50586,168.840,
4860.02539,863.598,5938.59717,168.840,
4860.11719,863.598,5938.68896,168.840,
4860.20850,863.598,5938.78027,169.840,
4860.30029,863.598,5938.87207,168.840,
4860.39160,862.598,5938.96338,169.840,
4860.48291,863.598,5939.05518,168.840,
4860.57471,862.598,5939.14648,168.840,
4860.66602,862.598,5939.23828,168.840,
4860.75781,863.598,5939.32959,168.840,
4860.84912,862.598,5939.42090,168.840,
4860.94092,862.598,5939.51270,168.840,
4861.03223,862.598,5939.60400,168.840,
4861.12402,862.598,5939.69580,168.840,
4861.21533,862.598,5939.78711,168.840,
4861.30664,862.598,5939.87891,168.840,
4861.39844,862.598,5939.97021,167.840,
4861.48975,861.598,5940.06152,168.840,
4861.58154,861.598,5940.15332,167.840,
4861.67285,861.598,5940.24463,168.840,
4861.76465,861.598,5940.33643,167.840,
4861.85596,860.598,5940.42773,167.840,
4861.94727,861.598,5940.51953,167.840,
4862.03906,860.598,5940.61084,167.840,
4862.13037,860.598,5940.70215,167.840,
4862.22217,860.598,5940.79395,167.840,
4862.31348,860.598,5940.88525,167.840,
4862.40527,860.598,5940.97705,167.840,
4862.49658,860.598,5941.06836,166.840,
4862.58789,860.598,5941.16016,167.840,
4862.67969,859.598,5941.25146,167.840,
4862.77100,859.598,5941.34326,166.840,
4862.86279,859.598,5941.43457,166.840,
4862.95410,859.598,5941.52588,166.840,
4863.04590,859.598,5941.61768,166.840,
4863.13721,859.598,5941.70898,166.840,
4863.22900,859.598,5941.80078,166.840,
4863.32031,859.598,5941.89209,166.840,
4863.41162,858.598,5941.98389,166.840,
4863.50342,858.598,5942.07520,166.840,
4863.59473,858.598,5942.16650,166.840,
4863.68652,858.598,5942.25830,165.840,
4863.77783,857.598,5942.34961,167.840,
4863.86963,858.598,5942.44141,165.840,
4863.96094,858.598,5942.53271,165.840,
4864.05225,858.598,5942.62451,166.840,
4864.14404,858.598,5942.71582,165.840,
4864.23535,857.598,5942.80713,165.840,
4864.32715,857.598,5942.89893,165.840,
4864.41846,857.598,5942.99023,165.840,
4864.51025,856.598,5943.08203,165.840,
4864.60156,856.598,5943.17334,165.840,
4864.69287,857.598,5943.26514,165.840,
4864.78467,856.598,5943.35645,165.840,
4864.87598,855.598,5943.44775,164.840,
4864.96777,856.598,5943.53955,165.840,
4865.05908,855.598,5943.63086,165.840,
4865.15088,856.598,5943.72266,164.840,
4865.24219,855.598,5943.81396,165.840,
4865.33398,855.598,5943.90576,164.840,
4865.42529,855.598,5943.99707,165.840,
4865.51660,855.598,5944.08887,164.840,
4865.60840,855.598,5944.18018,165.840,
4865.69971,855.598,5944.27148,164.840,
4865.79150,855.598,5944.36328,164.840,
4865.88281,854.598,5944.45459,164.840,
4865.97461,854.598,5944.54639,164.840,
4866.06592,855.598,5944.63770,165.840,
4866.15723,854.598,5944.72949,164.840,
4866.24902,854.598,5944.82080,164.840,
4866.34033,854.598,5944.91211,164.840,
4866.43213,854.598,5945.00391,164.840,
4866.52344,853.598,5945.09521,164.840,
4866.61523,853.598,5945.18701,164.840,
4866.70654,853.598,5945.27832,164.840,
4866.79785,853.598,5945.37012,163.840,
4866.88965,853.598,5945.46143,163.840,
4866.98096,853.598,5945.55273,163.840,
4867.07275,852.598,5945.64453,163.840,
4867.16406,852.598,5945.73584,163.840,
4867.25586,853.598,5945.82764,163.840,
4867.34717,852.598,5945.91895,162.840,
4867.43896,852.598,5946.01074,163.840,
4867.53027,852.598,5946.10205,163.840,
4867.62158,852.598,5946.19385,163.840,
4867.71338,852.598,5946.28516,163.840,
4867.80469,851.598,5946.37646,163.840,
4867.89648,852.598,5946.46826,163.840,
4867.98779,851.598,5946.55957,163.840,
4868.07959,851.598,5946.65137,162.840,
4868.17090,851.598,5946.74268,162.840,
4868.26221,851.598,5946.83447,162.840,
4868.35400,851.598,5946.92578,162.840,
4868.44531,851.598,5947.01709,163.840,
4868.53711,851.598,5947.10889,162.840,
4868.62842,850.598,5947.20020,162.840,
4868.72021,850.598,5947.29199,162.840,
4868.81152,850.598,5947.38330,162.840,
4868.90283,850.598,5947.47510,162.840,
4868.99463,850.598,5947.56641,162.840,
4869.08594,850.598,5947.65771,162.840,
4869.17773,850.598,5947.74951,162.840,
4869.26904,849.598,5947.84082,162.840,
4869.36084,849.598,5947.93262,162.840,
4869.45215,849.598,5948.02393,162.840,
4869.54346,849.598,5948.11572,162.840,
4869.63525,851.598,5948.20703,162.840,
4869.72656,851.598,5948.29883,161.840,
4869.81836,852.598,5948.39014,161.840,
4869.90967,852.598,5948.48145,161.840,
4870.00146,852.598,5948.57324,162.840,
4870.09277,852.598,5948.66455,161.840,
4870.18457,852.598,5948.75635,161.840,
4870.27588,852.598,5948.84766,162.840,
4870.36719,851.598,5948.93945,161.840,
4870.45898,851.598,5949.03076,161.840,
4870.55029,851.598,5949.12207,161.840,
4870.64209,850.598,5949.21387,161.840,
4870.73340,850.598,5949.30518,161.840,
4870.82520,849.598,5949.39697,161.840,
4870.91650,849.598,5949.48828,162.840,
4871.00781,849.598,5949.58008,161.840,
4871.09961,848.598,5949.67139,161.840,
4871.19092,848.598,5949.76270,161.840,
4871.28271,848.598,5949.85449,161.840,
4871.37402,847.598,5949.94580,160.840,
4871.46582,847.598,5950.03760,160.840,
4871.55713,846.598,5950.12891,161.840,
4871.64844,847.598,5950.22070,160.840,
4871.74023,847.598,5950.31201,160.840,
4871.83154,846.598,5950.40381,160.840,
4871.92334,846.598,5950.49512,161.840,
4872.01465,846.598,5950.58643,161.840,
4872.10645,845.598,5950.67822,161.840,
4872.19775,844.598,5950.76953,162.840,
4872.28955,844.598,5950.86133,162.840,
4872.38086,843.598,5950.95264,162.840,
4872.47217,842.598,5951.04443,162.840,
4872.56396,843.598,5951.13574,162.840,
4872.65527,842.598,5951.22705,162.840,
4872.74707,843.598,5951.31885,162.840,
4872.83838,843.598,5951.41016,162.840,
4872.93018,843.598,5951.50195,162.840,
4873.02148,843.598,5951.59326,161.840,
4873.11279,842.598,5951.68506,161.840,
4873.20459,843.598,5951.77637,161.840,
4873.29590,843.598,5951.86768,161.840,
4873.38770,843.598,5951.95947,161.840,
4873.47900,843.598,5952.05078,160.840,
4873.57080,843.598,5952.14258,160.840,
4873.66211,843.598,5952.23389,160.840,
4873.75342,842.598,5952.32568,159.840,
4873.84521,842.598,5952.41699,159.840,
4873.93652,843.598,5952.50879,159.840,
4874.02832,842.598,5952.60010,159.840,
4874.11963,842.598,5952.69141,158.840,
4874.21143,843.598,5952.78320,158.840,
4874.30273,842.598,5952.87451,158.840,
4874.39453,842.598,5952.96631,157.840,
4874.48584,843.598,5953.05762,157.840,
4874.57715,842.598,5953.14941,156.840,
4874.66895,842.598,5953.24072,155.840,
4874.76025,842.598,5953.33203,155.840,
4874.85205,842.598,5953.42383,155.840,
4874.94336,842.598,5953.51514,154.840,
4875.03516,841.598,5953.60693,155.840,
4875.12646,841.598,5953.69824,155.840,
4875.21777,841.598,5953.79004,155.840,
4875.30957,841.598,5953.88135,155.840,
4875.40088,841.598,5953.97266,155.840,
4875.49268,840.598,5954.06445,156.840,
4875.58398,840.598,5954.15576,155.840,
4875.67578,841.598,5954.24756,155.840,
4875.76709,840.598,5954.33887,156.840,
4875.85840,840.598,5954.43066,156.840,
4875.95020,840.598,5954.52197,156.840,
4876.04150,840.598,5954.61328,156.840,
4876.13330,840.598,5954.70508,156.840,
4876.22461,840.598,5954.79639,156.840,
4876.31641,840.598,5954.88818,157.840,
4876.40771,839.598,5954.97949,157.840,
4876.49951,839.598,5955.07129,157.840,
4876.59082,839.598,5955.16260,156.840,
4876.68213,840.598,5955.25439,156.840,
4876.77393,839.598,5955.34570,157.840,
4876.86523,839.598,5955.43701,157.840,
4876.95703,839.598,5955.52881,157.840,
4877.04834,838.598,5955.62012,157.840,
4877.14014,839.598,5955.71191,156.840,
4877.23145,838.598,5955.80322,156.840,
4877.32275,838.598,5955.89502,156.840,
4877.41455,838.598,5955.98633,156.840,
4877.50586,838.598,5956.07764,156.840,
4877.59766,838.598,5956.16943,156.840,
4877.68896,838.598,5956.26074,156.840,
4877.78076,838.598,5956.35254,156.840,
4877.87207,838.598,5956.44385,156.840,
4877.96338,837.598,5956.53564,156.840,
4878.05518,837.598,5956.62695,156.840,
4878.14648,837.598,5956.71826,156.840,
4878.23828,837.598,5956.81006,155.840,
4878.32959,837.598,5956.90137,156.840,
4878.42139,837.598,5956.99316,156.840,
4878.51270,837.598,5957.08447,155.840,
4878.60449,837.598,5957.17627,155.840,
4878.69580,837.598,5957.26758,155.840,
4878.78711,836.598,5957.35938,156.840,
4878.87891,836.598,5957.45068,155.840,
4878.97021,836.598,5957.54199,155.840,
4879.06201,836.598,5957.63379,155.840,
4879.15332,836.598,5957.72510,155.840,
4879.24512,836.598,5957.81689,156.840,
4879.33643,835.598,5957.90820,155.840,
4879.42773,835.598,5958.00000,155.840,
4879.51953,835.598,5958.09131,155.840,
4879.61084,835.598,5958.18262,155.840,
4879.70264,835.598,5958.27441,155.840,
4879.79395,835.598,5958.36572,155.840,
4879.88574,835.598,5958.45752,155.840,
4879.97705,835.598,5958.54883,155.840,
4880.06836,835.598,5958.64063,155.840,
4880.16016,834.598,5958.73193,154.840,
4880.25146,835.598,5958.82324,155.840,
4880.34326,834.598,5958.91504,154.840,
4880.43457,834.598,5959.00635,154.840,
4880.52637,834.598,5959.09814,154.840,
4880.61768,834.598,5959.18945,154.840,
4880.70947,834.598,5959.28125,154.840,
4880.80078,833.598,5959.37256,154.840,
4880.89209,833.598,5959.46436,153.840,
4880.98389,833.598,5959.55566,154.840,
4881.07520,833.598,5959.64697,154.840,
4881.16699,833.598,5959.73877,153.840,
4881.25830,832.598,5959.83008,154.840,
4881.35010,832.598,5959.92188,154.840,
4881.44141,833.598,5960.01318,153.840,
4881.53271,833.598,5960.10498,153.840,
4881.62451,832.598,5960.19629,153.840,
4881.71582,832.598,5960.28760,153.840,
4881.80762,832.598,5960.37939,154.840,
4881.89893,832.598,5960.47070,153.840,
4881.99072,832.598,5960.56250,153.840,
4882.08203,832.598,5960.65381,153.840,
4882.17334,831.598,5960.74561,154.840,
4882.26514,831.598,5960.83691,153.840,
4882.35645,831.598,5960.92822,153.840,
4882.44824,831.598,5961.02002,153.840,
4882.53955,831.598,5961.11133,153.840,
4882.63135,831.598,5961.20313,153.840,
4882.72266,830.598,5961.29443,153.840,
4882.81396,830.598,5961.38623,152.840,
4882.90576,830.598,5961.47754,152.840,
4882.99707,831.598,5961.56934,152.840,
4883.08887,830.598,5961.66064,152.840,
4883.18018,829.598,5961.75195,152.840,
4883.27197,830.598,5961.84375,152.840,
4883.36328,830.598,5961.93506,153.840,
4883.45508,830.598,5962.02686,152.840,
4883.54639,830.598,5962.11816,152.840,
4883.63770,829.598,5962.20996,153.840,
4883.72949,829.598,5962.30127,152.840,
4883.82080,829.598,5962.39258,152.840,
4883.91260,829.598,5962.48438,152.840,
4884.00391,828.598,5962.57568,152.840,
4884.09570,828.598,5962.66748,152.840,
4884.18701,829.598,5962.75879,151.840,
4884.27832,828.598,5962.85059,152.840,
4884.37012,828.598,5962.94189,152.840,
4884.46143,828.598,5963.03320,152.840,
4884.55322,828.598,5963.12500,152.840,
4884.64453,828.598,5963.21631,151.840,
4884.73633,828.598,5963.30811,152.840,
4884.82764,828.598,5963.39941,151.840,
4884.91895,828.598,5963.49121,151.840,
4885.01074,827.598,5963.58252,151.840,
4885.10205,828.598,5963.67432,152.840,
4885.19385,827.598,5963.76563,151.840,
4885.28516,827.598,5963.85693,151.840,
4885.37695,827.598,5963.94873,151.840,
4885.46826,827.598,5964.04004,151.840,
4885.56006,826.598,5964.13184,151.840,
4885.65137,827.598,5964.22314,151.840,
4885.74268,826.598,5964.31494,151.840,
4885.83447,826.598,5964.40625,151.840,
4885.92578,826.598,5964.49756,151.840,
4886.01758,826.598,5964.58936,150.840,
4886.10889,826.598,5964.68066,151.840,
4886.20068,826.598,5964.77246,151.840,
4886.29199,826.598,5964.86377,150.840,
4886.38330,826.598,5964.95557,150.840,
4886.47510,826.598,5965.04688,150.840,
4886.56641,826.598,5965.13818,151.840,
4886.65820,825.598,5965.22998,150.840,
4886.74951,825.598,5965.32129,150.840,
4886.84131,825.598,5965.41309,150.840,
4886.93262,825.598,5965.50439,150.840,
4887.02393,825.598,5965.59619,150.840,
4887.11572,825.598,5965.68750,150.840,
4887.20703,824.598,5965.77930,150.840,
4887.29883,824.598,5965.87061,150.840,
4887.39014,825.598,5965.96191,150.840,
4887.48193,824.598,5966.05371,150.840,
4887.57324,824.598,5966.14502,149.840,
4887.66504,824.598,5966.23682,150.840,
4887.75635,824.598,5966.32813,150.840,
4887.84766,824.598,5966.41992,150.840,
4887.93945,823.598,5966.51123,149.840,
4888.03076,823.598,5966.60254,151.840,
4888.12256,823.598,5966.69434,149.840,
4888.21387,823.598,5966.78564,149.840,
4888.30566,822.598,5966.87744,150.840,
4888.39697,822.598,5966.96875,149.840,
4888.48828,822.598,5967.06055,149.840,
4888.58008,821.598,5967.15186,149.840,
4888.67139,821.598,5967.24316,149.840,
4888.76318,820.598,5967.33496,148.840,
4888.85449,820.598,5967.42627,148.840,
4888.94629,820.598,5967.51807,148.840,
4889.03760,819.598,5967.60938,148.840,
4889.12891,820.598,5967.70117,148.840,
4889.22070,819.598,5967.79248,148.840,
4889.31201,820.598,5967.88379,148.840,
4889.40381,819.598,5967.97559,148.840,
4889.49512,819.598,5968.06689,149.840,
4889.58691,820.598,5968.15869,148.840,
4889.67822,819.598,5968.25000,148.840,
4889.77002,819.598,5968.34180,147.840,
4889.86133,819.598,5968.43311,148.840,
4889.95264,820.598,5968.52490,147.840,
4890.04443,819.598,5968.61621,146.840,
4890.13574,819.598,5968.70752,146.840,
4890.22754,819.598,5968.79932,146.840,
4890.31885,820.598,5968.89063,145.840,
4890.41064,819.598,5968.98242,145.840,
4890.50195,819.598,5969.07373,146.840,
4890.59326,820.598,5969.16553,145.840,
4890.68506,819.598,5969.25684,145.840,
4890.77637,819.598,5969.34814,145.840,
4890.86816,821.598,5969.43994,145.840,
4890.95947,821.598,5969.53125,146.840,
4891.05127,821.598,5969.62305,146.840,
4891.14258,821.598,5969.71436,146.840,
4891.23389,822.598,5969.80615,146.840,
4891.32568,822.598,5969.89746,146.840,
4891.41699,822.598,5969.98877,147.840,
4891.50879,821.598,5970.08057,147.840,
4891.60010,821.598,5970.17188,147.840,
4891.69189,821.598,5970.26367,146.840,
4891.78320,822.598,5970.35498,147.840,
4891.87500,821.598,5970.44678,146.840,
4891.96631,820.598,5970.53809,147.840,
4892.05762,820.598,5970.62988,147.840,
4892.14941,819.598,5970.72119,148.840,
4892.24072,819.598,5970.81250,148.840,
4892.33252,819.598,5970.90430,149.840,
4892.42383,819.598,5970.99561,150.840,
4892.51563,818.598,5971.08740,149.840,
4892.60693,817.598,5971.17871,150.840,
4892.69824,817.598,5971.27051,150.840,
4892.79004,817.598,5971.36182,150.840,
4892.88135,816.598,5971.45313,150.840,
4892.97314,817.598,5971.54492,150.840,
4893.06445,817.598,5971.63623,150.840,
4893.15625,816.598,5971.72803,149.840,
4893.24756,817.598,5971.81934,149.840,
4893.33887,816.598,5971.91113,148.840,
4893.43066,816.598,5972.00244,148.840,
4893.52197,816.598,5972.09375,147.840,
4893.61377,816.598,5972.18555,148.840,
4893.70508,815.598,5972.27686,147.840,
4893.79688,815.598,5972.36865,147.840,
4893.88818,815.598,5972.45996,147.840,
4893.97998,815.598,5972.55176,147.840,
4894.07129,814.598,5972.64307,146.840,
4894.16260,815.598,5972.73486,146.840,
4894.25439,815.598,5972.82617,146.840,
4894.34570,814.598,5972.91748,146.840,
4894.43750,815.598,5973.00928,146.840,
4894.52881,815.598,5973.10059,145.840,
4894.62061,815.598,5973.19238,145.840,
4894.71191,815.598,5973.28369,145.840,
4894.80322,814.598,5973.37549,145.840,
4894.89502,814.598,5973.46680,145.840,
4894.98633,814.598,5973.55811,144.840,
4895.07813,813.598,5973.64990,145.840,
4895.16943,813.598,5973.74121,145.840,
4895.26123,813.598,5973.83301,144.840,
4895.35254,813.598,5973.92432,145.840,
4895.44385,813.598,5974.01611,144.840,
4895.53564,813.598,5974.10742,144.840,
4895.62695,812.598,5974.19873,144.840,
4895.71875,812.598,5974.29053,144.840,
4895.81006,812.598,5974.38184,144.840,
4895.90186,812.598,5974.47363,144.840,
4895.99316,812.598,5974.56494,144.840,
4896.08447,812.598,5974.65674,144.840,
4896.17627,812.598,5974.74805,144.840,
4896.26758,812.598,5974.83984,144.840,
4896.35938,811.598,5974.93115,143.840,
4896.45068,812.598,5975.02246,143.840,
4896.54248,811.598,5975.11426,143.840,
4896.63379,811.598,5975.20557,144.840,
4896.72559,811.598,5975.29736,143.840,
4896.81689,811.598,5975.38867,144.840,
4896.90820,811.598,5975.48047,144.840,
4897.00000,811.598,5975.57178,143.840,
4897.09131,811.598,5975.66309,143.840,
4897.18311,811.598,5975.75488,143.840,
4897.27441,811.598,5975.84619,143.840,
4897.36621,810.598,5975.93799,143.840,
4897.45752,810.598,5976.02930,143.840,
4897.54883,811.598,5976.12109,143.840,
4897.64063,811.598,5976.21240,142.840,
4897.73193,810.598,5976.30371,143.840,
4897.82373,810.598,5976.39551,143.840,
4897.91504,810.598,5976.48682,142.840,
4898.00684,809.598,5976.57861,142.840,
4898.09814,809.598,5976.66992,143.840,
4898.18945,809.598,5976.76172,143.840,
4898.28125,809.598,5976.85303,143.840,
4898.37256,809.598,5976.94482,143.840,
4898.46436,809.598,5977.03613,143.840,
4898.55566,809.598,5977.12744,142.840,
4898.64746,809.598,5977.21924,142.840,
4898.73877,808.598,5977.31055,142.840,
4898.83057,808.598,5977.40234,142.840,
4898.92188,808.598,5977.49365,142.840,
4899.01318,808.598,5977.58545,142.840,
4899.10498,808.598,5977.67676,142.840,
4899.19629,808.598,5977.76807,142.840,
4899.28809,808.598,5977.85986,142.840,
4899.37939,808.598,5977.95117,142.840,
4899.47119,808.598,5978.04297,142.840,
4899.56250,807.598,5978.13428,142.840,
4899.65381,807.598,5978.22607,142.840,
4899.74561,807.598,5978.31738,142.840,
4899.83691,807.598,5978.40869,142.840,
4899.92871,807.598,5978.50049,142.840,
4900.02002,807.598,5978.59180,142.840,
4900.11182,806.598,5978.68359,142.840,
4900.20313,806.598,5978.77490,141.840,
4900.29443,807.598,5978.86670,142.840,
4900.38623,806.598,5978.95801,141.840,
4900.47754,806.598,5979.04980,141.840,
4900.56934,806.598,5979.14111,141.840,
4900.66064,806.598,5979.23242,141.840,
4900.75244,806.598,5979.32422,141.840,
4900.84375,805.598,5979.41553,141.840,
4900.93555,805.598,5979.50732,141.840,
4901.02686,805.598,5979.59863,140.840,
4901.11816,805.598,5979.69043,140.840,
4901.20996,805.598,5979.78174,141.840,
4901.30127,805.598,5979.87305,140.840,
4901.39307,804.598,5979.96484,141.840,
4901.48438,804.598,5980.05615,140.840,
4901.57617,804.598,5980.14795,141.840,
4901.66748,804.598,5980.23926,140.840,
4901.75879,804.598,5980.33105,141.840,
4901.85059,804.598,5980.42236,141.840,
4901.94189,803.598,5980.51367,140.840,
4902.03369,804.598,5980.60547,140.840,
4902.12500,803.598,5980.69678,140.840,
4902.21680,804.598,5980.78857,140.840,
4902.30811,804.598,5980.87988,140.840,
4902.39941,804.598,5980.97168,140.840,
4902.49121,803.598,5981.06299,140.840,
4902.58252,803.598,5981.15430,140.840,
4902.67432,803.598,5981.24609,141.840,
4902.76563,803.598,5981.33740,140.840,
4902.85742,803.598,5981.42920,139.840,
4902.94873,803.598,5981.52051,140.840,
4903.04053,802.598,5981.61230,140.840,
4903.13184,802.598,5981.70361,139.840,
4903.22314,802.598,5981.79541,139.840,
4903.31494,802.598,5981.88672,139.840,
4903.40625,802.598,5981.97803,139.840,
4903.49805,803.598,5982.06982,139.840,
4903.58936,802.598,5982.16113,139.840,
4903.68115,802.598,5982.25293,139.840,
4903.77246,802.598,5982.34424,139.840,
4903.86377,802.598,5982.43604,139.840,
4903.95557,802.598,5982.52734,138.840,
4904.04688,802.598,5982.61865,138.840,
4904.13867,801.598,5982.71045,139.840,
4904.22998,802.598,5982.80176,139.840,
4904.32178,801.598,5982.89355,139.840,
4904.41309,801.598,5982.98486,139.840,
4904.50439,801.598,5983.07666,138.840,
4904.59619,801.598,5983.16797,139.840,
4904.68750,800.598,5983.25928,139.840,
4904.77930,800.598,5983.35107,138.840,
4904.87061,800.598,5983.44238,138.840,
4904.96240,800.598,5983.53418,138.840,
4905.05371,800.598,5983.62549,138.840,
4905.14551,800.598,5983.71729,138.840,
4905.23682,799.598,5983.80859,138.840,
4905.32813,800.598,5983.90039,138.840,
4905.41992,800.598,5983.99170,138.840,
4905.51123,799.598,5984.08301,138.840,
4905.60303,799.598,5984.17480,139.840,
4905.69434,799.598,5984.26611,138.840,
4905.78613,799.598,5984.35791,138.840,
4905.87744,799.598,5984.44922,137.840,
4905.96875,799.598,5984.54102,138.840,
4906.06055,799.598,5984.63232,137.840,
4906.15186,799.598,5984.72363,138.840,
4906.24365,798.598,5984.81543,138.840,
4906.33496,798.598,5984.90674,137.840,
4906.42676,799.598,5984.99854,137.840,
4906.51807,798.598,5985.08984,137.840,
4906.60938,799.598,5985.18164,137.840,
4906.70117,798.598,5985.27295,137.840,
4906.79248,798.598,5985.36426,137.840,
4906.88428,798.598,5985.45605,137.840,
4906.97559,798.598,5985.54736,137.840,
4907.06738,797.598,5985.63916,137.840,
4907.15869,797.598,5985.73047,137.840,
4907.25000,797.598,5985.82227,137.840,
4907.34180,797.598,5985.91357,137.840,
4907.43311,796.598,5986.00537,136.840,
4907.52490,795.598,5986.09668,136.840,
4907.61621,795.598,5986.18799,137.840,
4907.70801,795.598,5986.27979,136.840,
4907.79932,795.598,5986.37109,136.840,
4907.89111,796.598,5986.46289,136.840,
4907.98242,794.598,5986.55420,136.840,
4908.07373,794.598,5986.64600,136.840,
4908.16553,794.598,5986.73730,135.840,
4908.25684,794.598,5986.82861,136.840,
4908.34863,794.598,5986.92041,136.840,
4908.43994,794.598,5987.01172,135.840,
4908.53174,794.598,5987.10352,136.840,
4908.62305,794.598,5987.19482,135.840,
4908.71436,794.598,5987.28662,135.840,
4908.80615,794.598,5987.37793,135.840,
4908.89746,794.598,5987.46924,135.840,
4908.98926,794.598,5987.56104,135.840,
4909.08057,794.598,5987.65234,135.840,
4909.17236,794.598,5987.74414,135.840,
4909.26367,794.598,5987.83545,135.840,
4909.35498,795.598,5987.92725,135.840,
4909.44678,796.598,5988.01855,135.840,
4909.53809,796.598,5988.11035,135.840,
4909.62988,797.598,5988.20166,135.840,
4909.72119,797.598,5988.29297,135.840,
4909.81299,797.598,5988.38477,135.840,
4909.90430,797.598,5988.47607,135.840,
4909.99609,798.598,5988.56787,135.840,
4910.08740,797.598,5988.65918,135.840,
4910.17871,797.598,5988.75098,135.840,
4910.27051,797.598,5988.84229,135.840,
4910.36182,797.598,5988.93359,135.840,
4910.45361,796.598,5989.02539,135.840,
4910.54492,796.598,5989.11670,134.840,
4910.63672,795.598,5989.20850,134.840,
4910.72803,795.598,5989.29980,134.840,
4910.81934,795.598,5989.39160,133.840,
4910.91113,794.598,5989.48291,134.840,
4911.00244,794.598,5989.57422,134.840,
4911.09424,793.598,5989.66602,134.840,
4911.18555,793.598,5989.75732,134.840,
4911.27734,793.598,5989.84912,134.840,
4911.36865,792.598,5989.94043,134.840,
4911.45996,792.598,5990.03223,134.840,
4911.55176,792.598,5990.12354,134.840,
4911.64307,791.598,5990.21533,133.840,
4911.73486,791.598,5990.30664,133.840,
4911.82617,791.598,5990.39795,133.840,
4911.91797,790.598,5990.48975,134.840,
4912.00928,791.598,5990.58105,133.840,
4912.10107,790.598,5990.67285,133.840,
4912.19238,790.598,5990.76416,134.840,
4912.28369,790.598,5990.85596,134.840,
4912.37549,790.598,5990.94727,133.840,
4912.46680,790.598,5991.03857,133.840,
4912.55859,790.598,5991.13037,133.840,
4912.64990,789.598,5991.22168,133.840,
4912.74170,789.598,5991.31348,133.840,
4912.83301,790.598,5991.40479,133.840,
4912.92432,789.598,5991.49658,134.840,
4913.01611,789.598,5991.58789,132.840,
4913.10742,789.598,5991.67920,133.840,
4913.19922,789.598,5991.77100,133.840,
4913.29053,789.598,5991.86230,133.840,
4913.38232,789.598,5991.95410,133.840,
4913.47363,788.598,5992.04541,133.840,
4913.56494,788.598,5992.13721,132.840,
4913.65674,788.598,5992.22852,132.840,
4913.74805,789.598,5992.31982,132.840,
4913.83984,788.598,5992.41162,132.840,
4913.93115,788.598,5992.50293,132.840,
4914.02295,788.598,5992.59473,132.840,
4914.11426,788.598,5992.68604,132.840,
4914.20605,788.598,5992.77783,132.840,
4914.29736,788.598,5992.86914,131.840,
4914.38867,787.598,5992.96094,132.840,
4914.48047,787.598,5993.05225,132.840,
4914.57178,787.598,5993.14355,132.840,
4914.66357,787.598,5993.23535,132.840,
4914.75488,787.598,5993.32666,132.840,
4914.84668,787.598,5993.41846,131.840,
4914.93799,786.598,5993.50977,132.840,
4915.02930,787.598,5993.60156,132.840,
4915.12109,786.598,5993.69287,131.840,
4915.21240,787.598,5993.78418,131.840,
4915.30420,786.598,5993.87598,132.840,
4915.39551,786.598,5993.96729,131.840,
4915.48730,786.598,5994.05908,131.840,
4915.57861,786.598,5994.15039,131.840,
4915.66992,785.598,5994.24219,131.840,
4915.76172,786.598,5994.33350,131.840,
4915.85303,786.598,5994.42480,131.840,
4915.94482,785.598,5994.51660,131.840,
4916.03613,786.598,5994.60791,131.840,
4916.12793,785.598,5994.69971,131.840,
4916.21924,785.598,5994.79102,130.840,
4916.31104,785.598,5994.88281,131.840,
4916.40234,785.598,5994.97412,130.840,
4916.49365,785.598,5995.06592,131.840,
4916.58545,784.598,5995.15723,131.840,
4916.67676,785.598,5995.24854,130.840,
4916.76855,785.598,5995.34033,130.840,
4916.85986,784.598,5995.43164,130.840,
4916.95166,784.598,5995.52344,130.840,
4917.04297,784.598,5995.61475,130.840,
4917.13428,784.598,5995.70654,131.840,
4917.22607,784.598,5995.79785,130.840,
4917.31738,784.598,5995.88916,131.840,
4917.40918,784.598,5995.98096,130.840,
4917.50049,783.598,5996.07227,130.840,
4917.59229,783.598,5996.16406,130.840,
4917.68359,783.598,5996.25537,131.840,
4917.77490,783.598,5996.34717,130.840,
4917.86670,783.598,5996.43848,130.840,
4917.95801,783.598,5996.52979,130.840,
4918.04980,783.598,5996.62158,130.840,
4918.14111,783.598,5996.71289,130.840,
4918.23291,783.598,5996.80469,129.840,
4918.32422,782.598,5996.89600,130.840,
4918.41602,782.598,5996.98779,129.840,
4918.50732,782.598,5997.07910,129.840,
4918.59863,782.598,5997.17090,129.840,
4918.69043,782.598,5997.26221,129.840,
4918.78174,782.598,5997.35352,129.840,
4918.87354,782.598,5997.44531,129.840,
4918.96484,781.598,5997.53662,130.840,
4919.05664,781.598,5997.62842,129.840,
4919.14795,781.598,5997.71973,129.840,
4919.23926,781.598,5997.81152,129.840,
4919.33105,781.598,5997.90283,129.840,
4919.42236,781.598,5997.99414,129.840,
4919.51416,781.598,5998.08594,129.840,
4919.60547,781.598,5998.17725,129.840,
4919.69727,781.598,5998.26904,128.840,
4919.78857,780.598,5998.36035,128.840,
4919.87988,780.598,5998.45215,129.840,
4919.97168,781.598,5998.54346,128.840,
4920.06299,780.598,5998.63477,128.840,
4920.15479,780.598,5998.72656,128.840,
4920.24609,780.598,5998.81787,129.840,
4920.33789,780.598,5998.90967,128.840,
4920.42920,779.598,5999.00098,128.840,
4920.52051,779.598,5999.09277,128.840,
4920.61230,779.598,5999.18408,128.840,
4920.70361,779.598,5999.27588,128.840,
4920.79541,779.598,5999.36719,128.840,
4920.88672,779.598,5999.45850,128.840,
4920.97852,778.598,5999.55029,128.840,
4921.06982,779.598,5999.64160,128.840,
4921.16162,778.598,5999.73340,128.840,
4921.25293,779.598,5999.82471,127.840,
4921.34424,779.598,5999.91650,127.840,
4921.43604,778.598,6000.00781,127.840,
4921.52734,778.598,6000.09912,127.840,
4921.61914,778.598,6000.19092,127.840,
4921.71045,778.598,6000.28223,128.840,
4921.80225,778.598,6000.37402,127.840,
4921.89355,778.598,6000.46533,127.840,
4921.98486,777.598,6000.55713,127.840,
4922.07666,778.598,6000.64844,127.840,
4922.16797,777.598,6000.73975,126.840,
4922.25977,777.598,6000.83154,126.840,
4922.35107,777.598,6000.92285,127.840,
4922.44287,777.598,6001.01465,127.840,
4922.53418,777.598,6001.10596,126.840,
4922.62549,777.598,6001.19775,127.840,
4922.71729,776.598,6001.28906,126.840,
4922.80859,777.598,6001.38086,126.840,
4922.90039,776.598,6001.47217,126.840,
4922.99170,776.598,6001.56348,126.840,
4923.08350,776.598,6001.65527,126.840,
4923.17480,775.598,6001.74658,126.840,
4923.26660,776.598,6001.83838,126.840,
4923.35791,775.598,6001.92969,126.840,
4923.44922,776.598,6002.02148,126.840,
4923.54102,775.598,6002.11279,126.840,
4923.63232,775.598,6002.20410,126.840,
4923.72412,775.598,6002.29590,126.840,
4923.81543,775.598,6002.38721,126.840,
4923.90723,774.598,6002.47900,126.840,
4923.99854,776.598,6002.57031,125.840,
4924.08984,774.598,6002.66211,125.840,
4924.18164,774.598,6002.75342,125.840,
4924.27295,774.598,6002.84473,125.840,
4924.36475,774.598,6002.93652,125.840,
4924.45605,774.598,6003.02783,125.840,
4924.54785,774.598,6003.11963,125.840,
4924.63916,774.598,6003.21094,125.840,
4924.73047,774.598,6003.30273,125.840,
4924.82227,773.598,6003.39404,125.840,
4924.91357,774.598,6003.48584,124.840,
4925.00537,773.598,6003.57715,125.840,
4925.09668,773.598,6003.66846,125.840,
4925.18848,773.598,6003.76025,124.840,
4925.27979,774.598,6003.85156,124.840,
4925.37158,773.598,6003.94336,124.840,
4925.46289,774.598,6004.03467,124.840,
4925.55420,774.598,6004.12646,124.840,
4925.64600,775.598,6004.21777,124.840,
4925.73730,775.598,6004.30908,124.840,
4925.82910,775.598,6004.40088,123.840,
4925.92041,776.598,6004.49219,124.840,
4926.01221,775.598,6004.58398,123.840,
4926.10352,776.598,6004.67529,124.840,
4926.19482,775.598,6004.76709,123.840,
4926.28662,775.598,6004.85840,123.840,
4926.37793,775.598,6004.94971,123.840,
4926.46973,774.598,6005.04150,123.840,
4926.56104,774.598,6005.13281,123.840,
4926.65283,774.598,6005.22461,123.840,
4926.74414,773.598,6005.31592,123.840,
4926.83545,773.598,6005.40771,122.840,
4926.92725,773.598,6005.49902,123.840,
4927.01855,773.598,6005.59033,122.840,
4927.11035,772.598,6005.68213,122.840,
4927.20166,771.598,6005.77344,123.840,
4927.29346,772.598,6005.86523,123.840,
4927.38477,771.598,6005.95654,123.840,
4927.47656,770.598,6006.04834,123.840,
4927.56787,771.598,6006.13965,123.840,
4927.65918,771.598,6006.23145,123.840,
4927.75098,769.598,6006.32275,123.840,
4927.84229,768.598,6006.41406,122.840,
4927.93408,768.598,6006.50586,123.840,
4928.02539,767.598,6006.59717,123.840,
4928.11719,766.598,6006.68896,124.840,
4928.20850,765.598,6006.78027,125.840,
4928.29980,765.598,6006.87207,125.840,
4928.39160,765.598,6006.96338,125.840,
4928.48291,765.598,6007.05469,125.840,
4928.57471,765.598,6007.14648,124.840,
4928.66602,764.598,6007.23779,124.840,
4928.75781,765.598,6007.32959,125.840,
4928.84912,765.598,6007.42090,124.840,
4928.94043,766.598,6007.51270,124.840,
4929.03223,765.598,6007.60400,124.840,
4929.12354,766.598,6007.69531,124.840,
4929.21533,766.598,6007.78711,123.840,
4929.30664,765.598,6007.87842,123.840,
4929.39844,766.598,6007.97021,123.840,
4929.48975,766.598,6008.06152,123.840,
4929.58154,767.598,6008.15332,123.840,
4929.67285,767.598,6008.24463,123.840,
4929.76416,767.598,6008.33643,122.840,
4929.85596,767.598,6008.42773,122.840,
4929.94727,767.598,6008.51904,122.840,
4930.03906,767.598,6008.61084,122.840,
4930.13037,767.598,6008.70215,122.840,
4930.22217,767.598,6008.79395,122.840,
4930.31348,766.598,6008.88525,122.840,
4930.40479,767.598,6008.97705,121.840,
4930.49658,767.598,6009.06836,123.840,
4930.58789,767.598,6009.15967,122.840,
4930.67969,766.598,6009.25146,121.840,
4930.77100,766.598,6009.34277,121.840,
4930.86279,765.598,6009.43457,122.840,
4930.95410,766.598,6009.52588,121.840,
4931.04541,766.598,6009.61768,121.840,
4931.13721,765.598,6009.70898,121.840,
4931.22852,766.598,6009.80029,121.840,
4931.32031,766.598,6009.89209,120.840,
4931.41162,765.598,6009.98340,121.840,
4931.50342,765.598,6010.07520,121.840,
4931.59473,765.598,6010.16650,120.840,
4931.68652,765.598,6010.25830,120.840,
4931.77783,765.598,6010.34961,121.840,
4931.86914,765.598,6010.44141,120.840,
4931.96094,765.598,6010.53271,121.840,
4932.05225,765.598,6010.62402,120.840,
4932.14404,764.598,6010.71582,121.840,
4932.23535,764.598,6010.80713,120.840,
4932.32715,764.598,6010.89893,120.840,
4932.41846,764.598,6010.99023,120.840,
4932.50977,764.598,6011.08203,121.840,
4932.60156,764.598,6011.17334,120.840,
4932.69287,763.598,6011.26465,121.840,
4932.78467,764.598,6011.35645,120.840,
4932.87598,764.598,6011.44775,120.840,
4932.96777,763.598,6011.53955,120.840,
4933.05908,763.598,6011.63086,120.840,
4933.15039,763.598,6011.72266,120.840,
4933.24219,763.598,6011.81396,120.840,
4933.33350,763.598,6011.90527,120.840,
4933.42529,763.598,6011.99707,120.840,
4933.51660,762.598,6012.08838,120.840,
4933.60840,762.598,6012.18018,120.840,
4933.69971,762.598,6012.27148,120.840,
4933.79102,762.598,6012.36328,120.840,
4933.88281,762.598,6012.45459,119.840,
4933.97412,761.598,6012.54639,120.840,
4934.06592,762.598,6012.63770,119.840,
4934.15723,761.598,6012.72900,119.840,
4934.24902,762.598,6012.82080,119.840,
4934.34033,762.598,6012.91211,119.840,
4934.43213,761.598,6013.00391,120.840,
4934.52344,761.598,6013.09521,119.840,
4934.61475,761.598,6013.18701,119.840,
4934.70654,761.598,6013.27832,119.840,
4934.79785,761.598,6013.36963,119.840,
4934.88965,761.598,6013.46143,119.840,
4934.98096,761.598,6013.55273,119.840,
4935.07275,761.598,6013.64453,119.840,
4935.16406,760.598,6013.73584,119.840,
4935.25537,760.598,6013.82764,118.840,
4935.34717,760.598,6013.91895,119.840,
4935.43848,760.598,6014.01025,119.840,
4935.53027,760.598,6014.10205,119.840,
4935.62158,760.598,6014.19336,119.840,
4935.71338,759.598,6014.28516,119.840,
4935.80469,760.598,6014.37646,118.840,
4935.89600,759.598,6014.46826,119.840,
4935.98779,759.598,6014.55957,118.840,
4936.07910,759.598,6014.65137,119.840,
4936.17090,759.598,6014.74268,119.840,
4936.26221,758.598,6014.83398,118.840,
4936.35400,759.598,6014.92578,119.840,
4936.44531,759.598,6015.01709,118.840,
4936.53711,758.598,6015.10889,119.840,
4936.62842,758.598,6015.20020,118.840,
4936.71973,758.598,6015.29199,119.840,
4936.81152,758.598,6015.38330,118.840,
4936.90283,758.598,6015.47461,118.840,
4936.99463,758.598,6015.56641,118.840,
4937.08594,758.598,6015.65771,118.840,
4937.17773,758.598,6015.74951,117.840,
4937.26904,758.598,6015.84082,118.840,
4937.36035,758.598,6015.93262,118.840,
4937.45215,758.598,6016.02393,118.840,
4937.54346,757.598,6016.11523,117.840,
4937.63525,757.598,6016.20703,118.840,
4937.72656,758.598,6016.29834,117.840,
4937.81836,757.598,6016.39014,118.840,
4937.90967,757.598,6016.48145,118.840,
4938.00098,757.598,6016.57324,118.840,
4938.09277,757.598,6016.66455,117.840,
4938.18408,756.598,6016.75586,117.840,
4938.27588,757.598,6016.84766,118.840,
4938.36719,756.598,6016.93896,117.840,
4938.45898,756.598,6017.03076,117.840,
4938.55029,756.598,6017.12207,117.840,
4938.64209,757.598,6017.21387,117.840,
4938.73340,756.598,6017.30518,117.840,
4938.82471,756.598,6017.39697,117.840,
4938.91650,756.598,6017.48828,117.840,
4939.00781,756.598,6017.57959,117.840,
4939.09961,755.598,6017.67139,116.840,
4939.19092,756.598,6017.76270,117.840,
4939.28271,755.598,6017.85449,117.840,
4939.37402,755.598,6017.94580,116.840,
4939.46533,755.598,6018.03760,117.840,
4939.55713,755.598,6018.12891,117.840,
4939.64844,755.598,6018.22021,116.840,
4939.74023,755.598,6018.31201,117.840,
4939.83154,755.598,6018.40332,116.840,
4939.92334,754.598,6018.49512,116.840,
4940.01465,754.598,6018.58643,116.840,
4940.10596,755.598,6018.67822,117.840,
4940.19775,754.598,6018.76953,116.840,
4940.28906,754.598,6018.86084,116.840,
4940.38086,754.598,6018.95264,116.840,
4940.47217,754.598,6019.04395,116.840,
4940.56396,754.598,6019.13574,116.840,
4940.65527,754.598,6019.22705,116.840,
4940.74707,753.598,6019.31885,116.840,
4940.83838,754.598,6019.41016,115.840,
4940.92969,753.598,6019.50195,116.840,
4941.02148,753.598,6019.59326,116.840,
4941.11279,753.598,6019.68457,116.840,
4941.20459,753.598,6019.77637,116.840,
4941.29590,753.598,6019.86768,116.840,
4941.38770,753.598,6019.95947,116.840,
4941.47900,752.598,6020.05078,116.840,
4941.57031,753.598,6020.14258,116.840,
4941.66211,753.598,6020.23389,115.840,
4941.75342,752.598,6020.32520,115.840,
4941.84521,752.598,6020.41699,115.840,
4941.93652,752.598,6020.50830,116.840,
4942.02832,752.598,6020.60010,115.840,
4942.11963,752.598,6020.69141,115.840,
4942.21094,752.598,6020.78320,116.840,
4942.30273,752.598,6020.87451,116.840,
4942.39404,751.598,6020.96582,115.840,
4942.48584,751.598,6021.05762,115.840,
4942.57715,752.598,6021.14893,115.840,
4942.66895,751.598,6021.24072,115.840,
4942.76025,751.598,6021.33203,115.840,
4942.85205,751.598,6021.42383,115.840,
4942.94336,751.598,6021.51514,115.840,
4943.03467,751.598,6021.60693,114.840,
4943.12646,751.598,6021.69824,115.840,
4943.21777,751.598,6021.78955,115.840,
4943.30957,751.598,6021.88135,115.840,
4943.40088,751.598,6021.97266,115.840,
4943.49268,751.598,6022.06445,115.840,
4943.58398,750.598,6022.15576,115.840,
4943.67529,750.598,6022.24756,116.840,
4943.76709,751.598,6022.33887,116.840,
4943.85840,750.598,6022.43018,116.840,
4943.95020,750.598,6022.52197,117.840,
4944.04150,751.598,6022.61328,117.840,
4944.13330,751.598,6022.70508,118.840,
4944.22461,751.598,6022.79639,118.840,
4944.31592,751.598,6022.88818,118.840,
4944.40771,751.598,6022.97949,118.840,
4944.49902,752.598,6023.07080,117.840,
4944.59082,752.598,6023.16260,117.840,
4944.68213,751.598,6023.25391,116.840,
4944.77393,751.598,6023.34570,116.840,
4944.86523,751.598,6023.43701,117.840,
4944.95654,751.598,6023.52881,116.840,
4945.04834,751.598,6023.62012,116.840,
4945.13965,749.598,6023.71191,116.840,
4945.23145,749.598,6023.80322,116.840,
4945.32275,749.598,6023.89453,116.840,
4945.41455,749.598,6023.98633,115.840,
4945.50586,749.598,6024.07764,115.840,
4945.59766,749.598,6024.16943,115.840,
4945.68896,748.598,6024.26074,115.840,
4945.78027,748.598,6024.35254,114.840,
4945.87207,747.598,6024.44385,114.840,
4945.96338,748.598,6024.53516,113.840,
4946.05518,747.598,6024.62695,113.840,
4946.14648,747.598,6024.71826,112.840,
4946.23828,747.598,6024.81006,111.840,
4946.32959,746.598,6024.90137,110.840,
4946.42090,745.598,6024.99316,109.840,
4946.51270,745.598,6025.08447,109.840,
4946.60400,744.598,6025.17578,109.840,
4946.69580,743.598,6025.26758,108.840,
4946.78711,742.598,6025.35889,108.840,
4946.87891,742.598,6025.45068,108.840,
4946.97021,742.598,6025.54199,109.840,
4947.06152,742.598,6025.63379,109.840,
4947.15332,742.598,6025.72510,110.840,
4947.24463,742.598,6025.81689,110.840,
4947.33643,741.598,6025.90820,110.840,
4947.42773,743.598,6025.99951,111.840,
4947.51953,742.598,6026.09131,111.840,
4947.61084,742.598,6026.18262,111.840,
4947.70264,743.598,6026.27441,111.840,
4947.79395,743.598,6026.36572,112.840,
4947.88525,743.598,6026.45752,111.840,
4947.97705,743.598,6026.54883,111.840,
4948.06836,743.598,6026.64014,112.840,
4948.16016,743.598,6026.73193,112.840,
4948.25146,743.598,6026.82324,112.840,
4948.34326,744.598,6026.91504,112.840,
4948.43457,743.598,6027.00635,113.840,
4948.52588,743.598,6027.09814,112.840,
4948.61768,743.598,6027.18945,112.840,
4948.70898,743.598,6027.28076,112.840,
4948.80078,743.598,6027.37256,112.840,
4948.89209,744.598,6027.46387,112.840,
4948.98389,743.598,6027.55566,112.840,
4949.07520,743.598,6027.64697,113.840,
4949.16650,743.598,6027.73877,112.840,
4949.25830,743.598,6027.83008,112.840,
4949.34961,743.598,6027.92188,112.840,
4949.44141,743.598,6028.01318,112.840,
4949.53271,742.598,6028.10449,112.840,
4949.62451,742.598,6028.19629,112.840,
4949.71582,742.598,6028.28760,112.840,
4949.80762,742.598,6028.37939,112.840,
4949.89893,742.598,6028.47070,112.840,
4949.99023,742.598,6028.56250,112.840,
4950.08203,742.598,6028.65381,112.840,
4950.17334,742.598,6028.74512,112.840,
4950.26514,741.598,6028.83691,112.840,
4950.35645,742.598,6028.92822,111.840,
4950.44824,742.598,6029.02002,112.840,
4950.53955,742.598,6029.11133,111.840,
4950.63086,741.598,6029.20313,111.840,
4950.72266,741.598,6029.29443,111.840,
4950.81396,741.598,6029.38574,111.840,
4950.90576,741.598,6029.47754,111.840,
4950.99707,741.598,6029.56885,112.840,
4951.08887,740.598,6029.66064,112.840,
4951.18018,740.598,6029.75195,112.840,
4951.27148,740.598,6029.84375,111.840,
4951.36328,740.598,6029.93506,111.840,
4951.45459,740.598,6030.02637,111.840,
4951.54639,739.598,6030.11816,111.840,
4951.63770,739.598,6030.20947,111.840,
4951.72949,740.598,6030.30127,111.840,
4951.82080,740.598,6030.39258,111.840,
4951.91260,739.598,6030.48438,111.840,
4952.00391,740.598,6030.57568,111.840,
4952.09521,739.598,6030.66748,111.840,
4952.18701,739.598,6030.75879,111.840,
4952.27832,739.598,6030.85010,111.840,
4952.37012,739.598,6030.94189,111.840,
4952.46143,739.598,6031.03320,112.840,
4952.55322,739.598,6031.12500,111.840,
4952.64453,739.598,6031.21631,111.840,
4952.73584,738.598,6031.30811,111.840,
4952.82764,738.598,6031.39941,111.840,
4952.91895,738.598,6031.49072,111.840,
4953.01074,737.598,6031.58252,111.840,
4953.10205,738.598,6031.67383,110.840,
4953.19385,738.598,6031.76563,110.840,
4953.28516,737.598,6031.85693,110.840,
4953.37646,738.598,6031.94873,110.840,
4953.46826,737.598,6032.04004,110.840,
4953.55957,737.598,6032.13135,111.840,
4953.65137,737.598,6032.22314,110.840,
4953.74268,737.598,6032.31445,110.840,
4953.83447,737.598,6032.40625,110.840,
4953.92578,736.598,6032.49756,110.840,
4954.01758,736.598,6032.58936,110.840,
4954.10889,737.598,6032.68066,110.840,
4954.20020,736.598,6032.77246,110.840,
4954.29199,736.598,6032.86377,110.840,
4954.38330,736.598,6032.95508,110.840,
4954.47510,736.598,6033.04688,110.840,
4954.56641,736.598,6033.13818,110.840,
4954.65820,736.598,6033.22998,110.840,
4954.74951,736.598,6033.32129,110.840,
4954.84082,736.598,6033.41309,110.840,
4954.93262,736.598,6033.50439,109.840,
4955.02393,736.598,6033.59570,109.840,
4955.11572,736.598,6033.68750,110.840,
4955.20703,736.598,6033.77881,109.840,
4955.29883,735.598,6033.87061,109.840,
4955.39014,736.598,6033.96191,110.840,
4955.48145,735.598,6034.05371,109.840,
4955.57324,735.598,6034.14502,109.840,
4955.66455,735.598,6034.23633,109.840,
4955.75635,735.598,6034.32813,109.840,
4955.84766,734.598,6034.41943,109.840,
4955.93945,734.598,6034.51123,109.840,
4956.03076,733.598,6034.60254,109.840,
4956.12256,734.598,6034.69434,109.840,
4956.21387,735.598,6034.78564,109.840,
4956.30518,734.598,6034.87744,109.840,
4956.39697,734.598,6034.96875,108.840,
4956.48828,734.598,6035.06006,108.840,
4956.58008,734.598,6035.15186,109.840,
4956.67139,733.598,6035.24316,109.840,
4956.76318,733.598,6035.33496,108.840,
4956.85449,733.598,6035.42627,109.840,
4956.94580,733.598,6035.51807,108.840,
4957.03760,733.598,6035.60938,109.840,
4957.12891,733.598,6035.70068,108.840,
4957.22070,733.598,6035.79248,109.840,
4957.31201,732.598,6035.88379,109.840,
4957.40381,733.598,6035.97559,108.840,
4957.49512,732.598,6036.06689,109.840,
4957.58643,732.598,6036.15869,109.840,
4957.67822,733.598,6036.25000,109.840,
4957.76953,732.598,6036.34131,109.840,
4957.86133,732.598,6036.43311,109.840,
4957.95264,731.598,6036.52441,109.840,
4958.04443,732.598,6036.61621,108.840,
4958.13574,732.598,6036.70752,108.840,
4958.22705,731.598,6036.79932,108.840,
4958.31885,732.598,6036.89063,109.840,
4958.41016,731.598,6036.98242,109.840,
4958.50195,730.598,6037.07373,108.840,
4958.59326,731.598,6037.16504,108.840,
4958.68506,731.598,6037.25684,108.840,
4958.77637,730.598,6037.34814,108.840,
4958.86816,731.598,6037.43994,108.840,
4958.95947,731.598,6037.53125,108.840,
4959.05078,730.598,6037.62305,108.840,
4959.14258,731.598,6037.71436,108.840,
4959.23389,730.598,6037.80566,107.840,
4959.32568,730.598,6037.89746,108.840,
4959.41699,730.598,6037.98877,108.840,
4959.50879,730.598,6038.08057,107.840,
4959.60010,731.598,6038.17188,107.840,
4959.69141,730.598,6038.26367,108.840,
4959.78320,730.598,6038.35498,108.840,
4959.87451,730.598,6038.44629,108.840,
4959.96631,729.598,6038.53809,107.840,
4960.05762,729.598,6038.62939,108.840,
4960.14941,729.598,6038.72119,107.840,
4960.24072,729.598,6038.81250,108.840,
4960.33203,729.598,6038.90430,107.840,
4960.42383,729.598,6038.99561,107.840,
4960.51514,729.598,6039.08740,107.840,
4960.60693,729.598,6039.17871,107.840,
4960.69824,729.598,6039.27002,107.840,
4960.79004,729.598,6039.36182,107.840,
4960.88135,729.598,6039.45313,106.840,
4960.97314,729.598,6039.54492,107.840,
4961.06445,728.598,6039.63623,107.840,
4961.15576,728.598,6039.72803,106.840,
4961.24756,728.598,6039.81934,107.840,
4961.33887,728.598,6039.91064,106.840,
4961.43066,728.598,6040.00244,106.840,
4961.52197,727.598,6040.09375,107.840,
4961.61377,728.598,6040.18555,107.840,
4961.70508,727.598,6040.27686,107.840,
4961.79639,727.598,6040.36865,106.840,
4961.88818,727.598,6040.45996,107.840,
4961.97949,727.598,6040.55127,107.840,
4962.07129,727.598,6040.64307,107.840,
4962.16260,727.598,6040.73438,107.840,
4962.25439,726.598,6040.82617,107.840,
4962.34570,726.598,6040.91748,106.840,
4962.43701,726.598,6041.00928,107.840,
4962.52881,727.598,6041.10059,107.840,
4962.62012,727.598,6041.19238,107.840,
4962.71191,727.598,6041.28369,107.840,
4962.80322,727.598,6041.37500,107.840,
4962.89502,727.598,6041.46680,107.840,
4962.98633,727.598,6041.55811,106.840,
4963.07813,727.598,6041.64990,106.840,
4963.16943,727.598,6041.74121,106.840,
4963.26074,727.598,6041.83301,106.840,
4963.35254,727.598,6041.92432,105.840,
4963.44385,727.598,6042.01563,106.840,
4963.53564,727.598,6042.10742,105.840,
4963.62695,726.598,6042.19873,105.840,
4963.71875,726.598,6042.29053,106.840,
4963.81006,726.598,6042.38184,105.840,
4963.90137,726.598,6042.47363,105.840,
4963.99316,725.598,6042.56494,105.840,
4964.08447,725.598,6042.65625,105.840,
4964.17627,725.598,6042.74805,106.840,
4964.26758,724.598,6042.83936,105.840,
4964.35938,724.598,6042.93115,105.840,
4964.45068,724.598,6043.02246,105.840,
4964.54199,725.598,6043.11426,106.840,
4964.63379,723.598,6043.20557,106.840,
4964.72510,724.598,6043.29688,106.840,
4964.81689,724.598,6043.38867,106.840,
4964.90820,724.598,6043.47998,106.840,
4965.00000,725.598,6043.57178,107.840,
4965.09131,724.598,6043.66309,106.840,
4965.18311,724.598,6043.75488,106.840,
4965.27441,724.598,6043.84619,106.840,
4965.36572,725.598,6043.93799,106.840,
4965.45752,724.598,6044.02930,106.840,
4965.54883,724.598,6044.12061,106.840,
4965.64063,724.598,6044.21240,106.840,
4965.73193,723.598,6044.30371,105.840,
4965.82373,723.598,6044.39551,105.840,
4965.91504,723.598,6044.48682,105.840,
4966.00635,722.598,6044.57861,105.840,
4966.09814,722.598,6044.66992,105.840,
4966.18945,722.598,6044.76123,105.840,
4966.28125,722.598,6044.85303,105.840,
4966.37256,721.598,6044.94434,104.840,
4966.46436,722.598,6045.03613,104.840,
4966.55566,722.598,6045.12744,104.840,
4966.64697,722.598,6045.21924,104.840,
4966.73877,721.598,6045.31055,105.840,
4966.83008,721.598,6045.40186,104.840,
4966.92188,721.598,6045.49365,104.840,
4967.01318,722.598,6045.58496,104.840,
4967.10498,721.598,6045.67676,104.840,
4967.19629,721.598,6045.76807,104.840,
4967.28809,721.598,6045.85986,104.840,
4967.37939,721.598,6045.95117,104.840,
4967.47070,721.598,6046.04297,103.840,
4967.56250,720.598,6046.13428,104.840,
4967.65381,720.598,6046.22559,104.840,
4967.74561,720.598,6046.31738,103.840,
4967.83691,721.598,6046.40869,104.840,
4967.92871,720.598,6046.50049,104.840,
4968.02002,719.598,6046.59180,103.840,
4968.11133,720.598,6046.68359,103.840,
4968.20313,719.598,6046.77490,103.840,
4968.29443,719.598,6046.86621,103.840,
4968.38623,719.598,6046.95801,103.840,
4968.47754,719.598,6047.04932,103.840,
4968.56934,719.598,6047.14111,104.840,
4968.66064,719.598,6047.23242,103.840,
4968.75195,719.598,6047.32422,103.840,
4968.84375,719.598,6047.41553,103.840,
4968.93506,719.598,6047.50684,103.840,
4969.02686,719.598,6047.59863,103.840,
4969.11816,719.598,6047.68994,103.840,
4969.20996,718.598,6047.78174,103.840,
4969.30127,719.598,6047.87305,103.840,
4969.39258,719.598,6047.96484,102.840,
4969.48438,718.598,6048.05615,103.840,
4969.57568,718.598,6048.14795,103.840,
4969.66748,718.598,6048.23926,103.840,
4969.75879,717.598,6048.33057,103.840,
4969.85059,717.598,6048.42236,102.840,
4969.94189,718.598,6048.51367,102.840,
4970.03369,717.598,6048.60547,103.840,
4970.12500,717.598,6048.69678,103.840,
4970.21631,717.598,6048.78857,103.840,
4970.30811,717.598,6048.87988,102.840,
4970.39941,716.598,6048.97119,103.840,
4970.49121,716.598,6049.06299,102.840,
4970.58252,717.598,6049.15430,102.840,
4970.67432,716.598,6049.24609,103.840,
4970.76563,716.598,6049.33740,103.840,
4970.85693,717.598,6049.42920,102.840,
4970.94873,716.598,6049.52051,102.840,
4971.04004,716.598,6049.61182,103.840,
4971.13184,716.598,6049.70361,102.840,
4971.22314,716.598,6049.79492,102.840,
4971.31494,716.598,6049.88672,102.840,
4971.40625,716.598,6049.97803,102.840,
4971.49756,716.598,6050.06982,102.840,
4971.58936,715.598,6050.16113,102.840,
4971.68066,715.598,6050.25293,102.840,
4971.77246,715.598,6050.34424,102.840,
4971.86377,715.598,6050.43555,102.840,
4971.95557,715.598,6050.52734,102.840,
4972.04688,715.598,6050.61865,102.840,
4972.13867,715.598,6050.71045,102.840,
4972.22998,715.598,6050.80176,101.840,
4972.32129,715.598,6050.89355,101.840,
4972.41309,715.598,6050.98486,101.840,
4972.50439,714.598,6051.07617,101.840,
4972.59619,714.598,6051.16797,102.840,
4972.68750,714.598,6051.25928,101.840,
4972.77930,714.598,6051.35107,101.840,
4972.87061,714.598,6051.44238,101.840,
4972.96191,714.598,6051.53418,102.840,
4973.05371,713.598,6051.62549,101.840,
4973.14502,713.598,6051.71680,101.840,
4973.23682,713.598,6051.80859,102.840,
4973.32813,713.598,6051.89990,101.840,
4973.41992,713.598,6051.99170,101.840,
4973.51123,713.598,6052.08301,101.840,
4973.60254,713.598,6052.17480,101.840,
4973.69434,713.598,6052.26611,101.840,
4973.78564,713.598,6052.35791,101.840,
4973.87744,713.598,6052.44922,101.840,
4973.96875,713.598,6052.54053,100.840,
4974.06055,713.598,6052.63232,100.840,
4974.15186,712.598,6052.72363,100.840,
4974.24365,712.598,6052.81543,101.840,
4974.33496,712.598,6052.90674,101.840,
4974.42627,712.598,6052.99854,102.840,
4974.51807,712.598,6053.08984,101.840,
4974.60938,712.598,6053.18115,100.840,
4974.70117,711.598,6053.27295,101.840,
4974.79248,712.598,6053.36426,101.840,
4974.88428,711.598,6053.45605,101.840,
4974.97559,712.598,6053.54736,100.840,
4975.06689,711.598,6053.63916,100.840,
4975.15869,711.598,6053.73047,100.840,
4975.25000,712.598,6053.82178,100.840,
4975.34180,711.598,6053.91357,100.840,
4975.43311,711.598,6054.00488,100.840,
4975.52490,711.598,6054.09668,100.840,
4975.61621,711.598,6054.18799,100.840,
4975.70752,711.598,6054.27979,100.840,
4975.79932,710.598,6054.37109,100.840,
4975.89063,710.598,6054.46240,101.840,
4975.98242,710.598,6054.55420,100.840,
4976.07373,710.598,6054.64551,100.840,
4976.16553,710.598,6054.73730,100.840,
4976.25684,710.598,6054.82861,100.840,
4976.34863,710.598,6054.92041,100.840,
4976.43994,709.598,6055.01172,100.840,
4976.53125,710.598,6055.10352,100.840,
4976.62305,710.598,6055.19482,100.840,
4976.71436,710.598,6055.28613,100.840,
4976.80615,710.598,6055.37793,99.840,
4976.89746,709.598,6055.46924,100.840,
4976.98926,709.598,6055.56104,100.840,
4977.08057,709.598,6055.65234,99.840,
4977.17188,709.598,6055.74414,100.840,
4977.26367,709.598,6055.83545,100.840,
4977.35498,709.598,6055.92676,100.840,
4977.44678,708.598,6056.01855,100.840,
4977.53809,709.598,6056.10986,99.840,
4977.62988,708.598,6056.20166,100.840,
4977.72119,708.598,6056.29297,99.840,
4977.81250,708.598,6056.38477,99.840,
4977.90430,708.598,6056.47607,99.840,
4977.99561,708.598,6056.56738,99.840,
4978.08740,708.598,6056.65918,100.840,
4978.17871,708.598,6056.75049,99.840,
4978.27051,708.598,6056.84229,99.840,
4978.36182,707.598,6056.93359,99.840,
4978.45361,708.598,6057.02539,99.840,
4978.54492,707.598,6057.11670,99.840,
4978.63623,707.598,6057.20850,99.840,
4978.72803,707.598,6057.29980,99.840,
4978.81934,707.598,6057.39111,100.840,
4978.91113,707.598,6057.48291,99.840,
4979.00244,707.598,6057.57422,99.840,
4979.09424,707.598,6057.66602,99.840,
4979.18555,706.598,6057.75732,99.840,
4979.27686,706.598,6057.84912,98.840,
4979.36865,706.598,6057.94043,99.840,
4979.45996,706.598,6058.03174,98.840,
4979.55176,706.598,6058.12354,98.840,
4979.64307,707.598,6058.21484,99.840,
4979.73486,706.598,6058.30664,98.840,
4979.82617,706.598,6058.39795,99.840,
4979.91748,706.598,6058.48975,99.840,
4980.00928,706.598,6058.58105,99.840,
4980.10059,706.598,6058.67236,99.840,
4980.19238,706.598,6058.76416,99.840,
4980.28369,705.598,6058.85547,100.840,
4980.37549,705.598,6058.94727,99.840,
4980.46680,705.598,6059.03857,99.840,
4980.55859,705.598,6059.13037,100.840,
4980.64990,704.598,6059.22168,100.840,
4980.74121,705.598,6059.31348,100.840,
4980.83301,705.598,6059.40479,100.840,
4980.92432,705.598,6059.49609,99.840,
4981.01611,704.598,6059.58789,99.840,
4981.10742,705.598,6059.67920,99.840,
4981.19922,704.598,6059.77100,99.840,
4981.29053,704.598,6059.86230,99.840,
4981.38184,703.598,6059.95410,99.840,
4981.47363,703.598,6060.04541,98.840,
4981.56494,703.598,6060.13672,98.840,
4981.65674,702.598,6060.22852,98.840,
4981.74805,702.598,6060.31982,99.840,
4981.83984,702.598,6060.41162,98.840,
4981.93115,701.598,6060.50293,97.840,
4982.02246,701.598,6060.59473,98.840,
4982.11426,700.598,6060.68604,97.840,
4982.20557,701.598,6060.77734,97.840,
4982.29736,701.598,6060.86914,97.840,
4982.38867,701.598,6060.96045,96.840,
4982.48047,701.598,6061.05225,96.840,
4982.57178,701.598,6061.14355,96.840,
4982.66309,701.598,6061.23535,96.840,
4982.75488,701.598,6061.32666,96.840,
4982.84619,701.598,6061.41846,95.840,
4982.93799,701.598,6061.50977,96.840,
4983.02930,701.598,6061.60107,95.840,
4983.12109,701.598,6061.69287,95.840,
4983.21240,702.598,6061.78418,96.840,
4983.30420,701.598,6061.87598,95.840,
4983.39551,701.598,6061.96729,95.840,
4983.48682,701.598,6062.05908,95.840,
4983.57861,702.598,6062.15039,95.840,
4983.66992,702.598,6062.24170,95.840,
4983.76172,702.598,6062.33350,95.840,
4983.85303,703.598,6062.42480,95.840,
4983.94482,703.598,6062.51660,95.840,
4984.03613,704.598,6062.60791,95.840,
4984.12744,704.598,6062.69971,95.840,
4984.21924,703.598,6062.79102,96.840,
4984.31055,703.598,6062.88232,95.840,
4984.40234,704.598,6062.97412,96.840,
4984.49365,704.598,6063.06543,96.840,
4984.58545,703.598,6063.15723,96.840,
4984.67676,703.598,6063.24854,96.840,
4984.76807,703.598,6063.34033,96.840,
4984.85986,702.598,6063.43164,96.840,
4984.95117,702.598,6063.52344,96.840,
4985.04297,702.598,6063.61475,96.840,
4985.13428,701.598,6063.70605,96.840,
4985.22607,700.598,6063.79785,96.840,
4985.31738,701.598,6063.88916,96.840,
4985.40918,700.598,6063.98096,96.840,
4985.50049,700.598,6064.07227,96.840,
4985.59180,700.598,6064.16406,96.840,
4985.68359,700.598,6064.25537,96.840,
4985.77490,699.598,6064.34668,96.840,
4985.86670,699.598,6064.43848,96.840,
4985.95801,698.598,6064.52979,95.840,
4986.04980,699.598,6064.62158,96.840,
4986.14111,699.598,6064.71289,96.840,
4986.23242,698.598,6064.80469,95.840,
4986.32422,699.598,6064.89600,96.840,
4986.41553,698.598,6064.98730,96.840,
4986.50732,697.598,6065.07910,96.840,
4986.59863,698.598,6065.17041,96.840,
4986.69043,698.598,6065.26221,95.840,
4986.78174,697.598,6065.35352,95.840,
4986.87305,697.598,6065.44531,95.840,
4986.96484,698.598,6065.53662,95.840,
4987.05615,697.598,6065.62842,95.840,
4987.14795,697.598,6065.71973,95.840,
4987.23926,697.598,6065.81104,95.840,
4987.33105,697.598,6065.90283,95.840,
4987.42236,697.598,6065.99414,95.840,
4987.51416,697.598,6066.08594,95.840,
4987.60547,697.598,6066.17725,95.840,
4987.69678,696.598,6066.26904,95.840,
4987.78857,696.598,6066.36035,94.840,
4987.87988,697.598,6066.45166,95.840,
4987.97168,696.598,6066.54346,95.840,
4988.06299,696.598,6066.63477,94.840,
4988.15479,696.598,6066.72656,95.840,
4988.24609,696.598,6066.81787,94.840,
4988.33740,696.598,6066.90967,94.840,
4988.42920,696.598,6067.00098,94.840,
4988.52051,695.598,6067.09229,94.840,
4988.61230,696.598,6067.18408,95.840,
4988.70361,695.598,6067.27539,94.840,
4988.79541,696.598,6067.36719,94.840,
4988.88672,695.598,6067.45850,94.840,
4988.97803,695.598,6067.55029,94.840,
4989.06982,695.598,6067.64160,95.840,
4989.16113,695.598,6067.73291,94.840,
4989.25293,695.598,6067.82471,94.840,
4989.34424,694.598,6067.91602,94.840,
4989.43604,695.598,6068.00781,95.840,
4989.52734,694.598,6068.09912,94.840,
4989.61914,694.598,6068.19092,95.840,
4989.71045,695.598,6068.28223,94.840,
4989.80176,694.598,6068.37402,94.840,
4989.89355,695.598,6068.46533,94.840,
4989.98486,694.598,6068.55664,94.840,
4990.07666,694.598,6068.64844,94.840,
4990.16797,694.598,6068.73975,94.840,
4990.25977,694.598,6068.83154,93.840,
4990.35107,694.598,6068.92285,94.840,
4990.44238,694.598,6069.01465,93.840,
4990.53418,694.598,6069.10596,94.840,
4990.62549,694.598,6069.19727,93.840,
4990.71729,693.598,6069.28906,94.840,
4990.80859,693.598,6069.38037,94.840,
4990.90039,693.598,6069.47217,93.840,
4990.99170,693.598,6069.56348,93.840,
4991.08301,693.598,6069.65527,93.840,
4991.17480,693.598,6069.74658,93.840,
4991.26611,692.598,6069.83789,93.840,
4991.35791,693.598,6069.92969,93.840,
4991.44922,692.598,6070.02100,93.840,
4991.54102,692.598,6070.11279,93.840,
4991.63232,692.598,6070.20410,93.840,
4991.72412,692.598,6070.29590,92.840,
4991.81543,692.598,6070.38721,92.840,
4991.90674,692.598,6070.47900,93.840,
4991.99854,691.598,6070.57031,93.840,
4992.08984,691.598,6070.66162,93.840,
4992.18164,691.598,6070.75342,93.840,
4992.27295,691.598,6070.84473,93.840,
4992.36475,691.598,6070.93652,93.840,
4992.45605,691.598,6071.02783,93.840,
4992.54736,691.598,6071.11963,93.840,
4992.63916,691.598,6071.21094,92.840,
4992.73047,691.598,6071.30225,93.840,
4992.82227,691.598,6071.39404,92.840,
4992.91357,690.598,6071.48535,92.840,
4993.00537,691.598,6071.57715,92.840,
4993.09668,690.598,6071.66846,93.840,
4993.18799,690.598,6071.76025,93.840,
4993.27979,690.598,6071.85156,92.840,
4993.37109,690.598,6071.94287,92.840,
4993.46289,690.598,6072.03467,93.840,
4993.55420,690.598,6072.12598,92.840,
4993.64600,689.598,6072.21777,93.840,
4993.73730,689.598,6072.30908,92.840,
4993.82910,689.598,6072.40088,93.840,
4993.92041,689.598,6072.49219,92.840,
4994.01172,689.598,6072.58398,92.840,
4994.10352,689.598,6072.67529,92.840,
4994.19482,689.598,6072.76660,92.840,
4994.28662,690.598,6072.85840,92.840,
4994.37793,689.598,6072.94971,92.840,
4994.46973,688.598,6073.04150,92.840,
4994.56104,689.598,6073.13281,92.840,
4994.65234,688.598,6073.22461,92.840,
4994.74414,688.598,6073.31592,91.840,
4994.83545,688.598,6073.40723,92.840,
4994.92725,688.598,6073.49902,92.840,
4995.01855,688.598,6073.59033,92.840,
4995.11035,688.598,6073.68213,91.840,
4995.20166,688.598,6073.77344,92.840,
4995.29297,687.598,6073.86523,92.840,
4995.38477,687.598,6073.95654,92.840,
4995.47607,687.598,6074.04785,92.840,
4995.56787,687.598,6074.13965,92.840,
4995.65918,687.598,6074.23096,91.840,
4995.75098,688.598,6074.32275,91.840,
4995.84229,688.598,6074.41406,91.840,
4995.93359,687.598,6074.50586,91.840,
4996.02539,687.598,6074.59717,91.840,
4996.11670,687.598,6074.68896,90.840,
4996.20850,687.598,6074.78027,91.840,
4996.29980,687.598,6074.87158,91.840,
4996.39160,687.598,6074.96338,91.840,
4996.48291,687.598,6075.05469,91.840,
4996.57471,686.598,6075.14648,91.840,
4996.66602,687.598,6075.23779,91.840,
4996.75732,686.598,6075.32959,91.840,
4996.84912,686.598,6075.42090,91.840,
4996.94043,686.598,6075.51221,91.840,
4997.03223,686.598,6075.60400,91.840,
4997.12354,686.598,6075.69531,91.840,
4997.21533,687.598,6075.78711,90.840,
4997.30664,686.598,6075.87842,91.840,
4997.39795,686.598,6075.97021,91.840,
4997.48975,686.598,6076.06152,91.840,
4997.58105,685.598,6076.15283,90.840,
4997.67285,685.598,6076.24463,90.840,
4997.76416,685.598,6076.33594,90.840,
4997.85596,686.598,6076.42773,90.840,
4997.94727,684.598,6076.51904,89.840,
4998.03857,685.598,6076.61084,89.840,
4998.13037,685.598,6076.70215,89.840,
4998.22168,685.598,6076.79395,88.840,
4998.31348,684.598,6076.88525,89.840,
4998.40479,684.598,6076.97656,89.840,
4998.49658,684.598,6077.06836,89.840,
4998.58789,684.598,6077.15967,89.840,
4998.67969,684.598,6077.25146,89.840,
4998.77100,684.598,6077.34277,89.840,
4998.86230,684.598,6077.43457,89.840,
4998.95410,684.598,6077.52588,89.840,
4999.04541,684.598,6077.61719,89.840,
4999.13721,684.598,6077.70898,89.840,
4999.22852,683.598,6077.80029,90.840,
4999.32031,683.598,6077.89209,90.840,
4999.41162,683.598,6077.98340,89.840,
4999.50293,683.598,6078.07520,90.840,
4999.59473,683.598,6078.16650,89.840,
4999.68604,683.598,6078.25781,90.840,
4999.77783,683.598,6078.34961,90.840,
4999.86914,682.598,6078.44092,90.840,
4999.96094,682.598,6078.53271,90.840,
5000.05225,683.598,6078.62402,89.840,
5000.14355,683.598,6078.71582,89.840,
5000.23535,683.598,6078.80713,89.840,
5000.32666,683.598,6078.89893,89.840,
5000.41846,683.598,6078.99023,89.840,
5000.50977,684.598,6079.08154,90.840,
5000.60156,685.598,6079.17334,90.840,
5000.69287,685.598,6079.26465,90.840,
5000.78467,685.598,6079.35645,91.840,
5000.87598,684.598,6079.44775,91.840,
5000.96729,684.598,6079.53955,90.840,
5001.05908,684.598,6079.63086,91.840,
5001.15039,684.598,6079.72217,91.840,
5001.24219,684.598,6079.81396,90.840,
5001.33350,684.598,6079.90527,90.840,
5001.42529,683.598,6079.99707,90.840,
5001.51660,683.598,6080.08838,90.840,
5001.60791,683.598,6080.18018,89.840,
5001.69971,682.598,6080.27148,90.840,
5001.79102,682.598,6080.36279,89.840,
5001.88281,681.598,6080.45459,89.840,
5001.97412,681.598,6080.54590,89.840,
5002.06592,681.598,6080.63770,89.840,
5002.15723,681.598,6080.72900,89.840,
5002.24854,681.598,6080.82080,89.840,
5002.34033,681.598,6080.91211,89.840,
5002.43164,680.598,6081.00342,88.840,
5002.52344,679.598,6081.09521,89.840,
5002.61475,678.598,6081.18652,88.840,
5002.70654,679.598,6081.27832,89.840,
5002.79785,678.598,6081.36963,88.840,
5002.88965,677.598,6081.46143,88.840,
5002.98096,676.598,6081.55273,88.840,
5003.07227,676.598,6081.64453,88.840,
5003.16406,675.598,6081.73584,89.840,
5003.25537,675.598,6081.82715,88.840,
5003.34717,675.598,6081.91895,88.840,
5003.43848,675.598,6082.01025,88.840,
5003.53027,675.598,6082.10205,88.840,
5003.62158,675.598,6082.19336,88.840,
5003.71289,676.598,6082.28516,89.840,
5003.80469,676.598,6082.37646,88.840,
5003.89600,676.598,6082.46777,88.840,
5003.98779,676.598,6082.55957,88.840,
5004.07910,677.598,6082.65088,88.840,
5004.17090,676.598,6082.74268,88.840,
5004.26221,676.598,6082.83398,88.840,
5004.35352,677.598,6082.92578,87.840,
5004.44531,677.598,6083.01709,88.840,
5004.53662,677.598,6083.10840,88.840,
5004.62842,677.598,6083.20020,87.840,
5004.71973,677.598,6083.29150,88.840,
5004.81152,676.598,6083.38330,88.840,
5004.90283,677.598,6083.47461,87.840,
5004.99463,676.598,6083.56641,87.840,
5005.08594,677.598,6083.65771,87.840,
5005.17725,676.598,6083.74951,88.840,
5005.26904,676.598,6083.84082,87.840,
5005.36035,676.598,6083.93213,87.840,
5005.45215,676.598,6084.02393,88.840,
5005.54346,676.598,6084.11523,87.840,
5005.63525,675.598,6084.20703,87.840,
5005.72656,675.598,6084.29834,88.840,
5005.81787,676.598,6084.39014,87.840,
5005.90967,676.598,6084.48145,87.840,
5006.00098,676.598,6084.57275,87.840,
5006.09277,675.598,6084.66455,87.840,
5006.18408,675.598,6084.75586,87.840,
5006.27588,675.598,6084.84766,87.840,
5006.36719,675.598,6084.93896,87.840,
5006.45850,675.598,6085.03076,87.840,
5006.55029,675.598,6085.12207,87.840,
5006.64160,675.598,6085.21338,88.840,
5006.73340,675.598,6085.30518,87.840,
5006.82471,675.598,6085.39648,87.840,
5006.91650,674.598,6085.48828,87.840,
5007.00781,675.598,6085.57959,87.840,
5007.09912,675.598,6085.67139,86.840,
5007.19092,675.598,6085.76270,86.840,
5007.28223,674.598,6085.85449,86.840,
5007.37402,674.598,6085.94580,87.840,
5007.46533,675.598,6086.03711,86.840,
5007.55713,674.598,6086.12891,86.840,
5007.64844,675.598,6086.22021,86.840,
5007.74023,674.598,6086.31201,86.840,
5007.83154,673.598,6086.40332,86.840,
5007.92285,674.598,6086.49512,86.840,
5008.01465,673.598,6086.58643,86.840,
5008.10596,674.598,6086.67773,87.840,
5008.19775,673.598,6086.76953,87.840,
5008.28906,673.598,6086.86084,86.840,
5008.38086,673.598,6086.95264,86.840,
5008.47217,674.598,6087.04395,86.840,
5008.56348,673.598,6087.13574,86.840,
5008.65527,673.598,6087.22705,86.840,
5008.74658,673.598,6087.31836,86.840,
5008.83838,673.598,6087.41016,86.840,
5008.92969,674.598,6087.50146,86.840,
5009.02148,673.598,6087.59326,86.840,
5009.11279,673.598,6087.68457,86.840,
5009.20410,673.598,6087.77637,86.840,
5009.29590,673.598,6087.86768,85.840,
5009.38721,673.598,6087.95947,86.840,
5009.47900,673.598,6088.05078,85.840,
5009.57031,672.598,6088.14209,85.840,
5009.66211,672.598,6088.23389,85.840,
5009.75342,672.598,6088.32520,86.840,
5009.84521,672.598,6088.41699,85.840,
5009.93652,671.598,6088.50830,86.840,
5010.02783,672.598,6088.60010,86.840,
5010.11963,671.598,6088.69141,86.840,
5010.21094,671.598,6088.78271,86.840,
5010.30273,671.598,6088.87451,86.840,
5010.39404,672.598,6088.96582,85.840,
5010.48584,671.598,6089.05762,86.840,
5010.57715,671.598,6089.14893,85.840,
5010.66846,671.598,6089.24072,85.840,
5010.76025,671.598,6089.33203,85.840,
5010.85156,670.598,6089.42334,85.840,
5010.94336,670.598,6089.51514,86.840,
5011.03467,670.598,6089.60645,86.840,
5011.12646,670.598,6089.69824,86.840,
5011.21777,670.598,6089.78955,86.840,
5011.30908,670.598,6089.88135,85.840,
5011.40088,670.598,6089.97266,86.840,
5011.49219,669.598,6090.06445,85.840,
5011.58398,669.598,6090.15576,85.840,
5011.67529,669.598,6090.24707,86.840,
5011.76709,669.598,6090.33887,85.840,
5011.85840,670.598,6090.43018,85.840,
5011.95020,669.598,6090.52197,85.840,
5012.04150,669.598,6090.61328,85.840,
5012.13281,669.598,6090.70508,85.840,
5012.22461,669.598,6090.79639,85.840,
5012.31592,669.598,6090.88770,84.840,
5012.40771,669.598,6090.97949,84.840,
5012.49902,668.598,6091.07080,85.840,
5012.59082,668.598,6091.16260,85.840,
5012.68213,668.598,6091.25391,84.840,
5012.77344,668.598,6091.34570,85.840,
5012.86523,668.598,6091.43701,84.840,
5012.95654,668.598,6091.52832,84.840,
5013.04834,668.598,6091.62012,85.840,
5013.13965,667.598,6091.71143,85.840,
5013.23145,668.598,6091.80322,84.840,
5013.32275,668.598,6091.89453,85.840,
5013.41406,667.598,6091.98633,84.840,
5013.50586,667.598,6092.07764,84.840,
5013.59717,667.598,6092.16895,84.840,
5013.68896,667.598,6092.26074,84.840,
5013.78027,667.598,6092.35205,84.840,
5013.87207,667.598,6092.44385,84.840,
5013.96338,667.598,6092.53516,85.840,
5014.05518,667.598,6092.62695,84.840,
5014.14648,666.598,6092.71826,84.840,
5014.23779,666.598,6092.81006,84.840,
5014.32959,666.598,6092.90137,84.840,
5014.42090,666.598,6092.99268,84.840,
5014.51270,666.598,6093.08447,84.840,
5014.60400,666.598,6093.17578,85.840,
5014.69580,666.598,6093.26758,84.840,
5014.78711,666.598,6093.35889,84.840,
5014.87842,666.598,6093.45068,84.840,
5014.97021,666.598,6093.54199,84.840,
5015.06152,666.598,6093.63330,83.840,
5015.15332,665.598,6093.72510,84.840,
5015.24463,666.598,6093.81641,84.840,
5015.33643,665.598,6093.90820,84.840,
5015.42773,665.598,6093.99951,85.840,
5015.51904,665.598,6094.09131,85.840,
5015.61084,665.598,6094.18262,86.840,
5015.70215,665.598,6094.27393,86.840,
5015.79395,664.598,6094.36572,86.840,
5015.88525,664.598,6094.45703,87.840,
5015.97705,664.598,6094.54883,86.840,
5016.06836,665.598,6094.64014,87.840,
5016.16016,665.598,6094.73193,87.840,
5016.25146,665.598,6094.82324,86.840,
5016.34277,664.598,6094.91504,86.840,
5016.43457,664.598,6095.00635,86.840,
5016.52588,664.598,6095.09766,86.840,
5016.61768,664.598,6095.18945,86.840,
5016.70898,663.598,6095.28076,86.840,
5016.80078,664.598,6095.37256,85.840,
5016.89209,664.598,6095.46387,85.840,
5016.98340,663.598,6095.55566,85.840,
5017.07520,663.598,6095.64697,84.840,
5017.16650,663.598,6095.73828,84.840,
5017.25830,663.598,6095.83008,84.840,
5017.34961,663.598,6095.92139,83.840,
5017.44141,663.598,6096.01318,83.840,
5017.53271,663.598,6096.10449,83.840,
5017.62402,663.598,6096.19629,83.840,
5017.71582,664.598,6096.28760,83.840,
5017.80713,662.598,6096.37891,82.840,
5017.89893,662.598,6096.47070,81.840,
5017.99023,662.598,6096.56201,80.840,
5018.08203,662.598,6096.65381,80.840,
5018.17334,662.598,6096.74512,79.840,
5018.26514,663.598,6096.83691,79.840,
5018.35645,662.598,6096.92822,78.840,
5018.44775,662.598,6097.02002,79.840,
5018.53955,662.598,6097.11133,79.840,
5018.63086,662.598,6097.20264,78.840,
5018.72266,661.598,6097.29443,79.840,
5018.81396,662.598,6097.38574,79.840,
5018.90576,662.598,6097.47754,80.840,
5018.99707,662.598,6097.56885,79.840,
5019.08838,662.598,6097.66064,80.840,
5019.18018,663.598,6097.75195,80.840,
5019.27148,662.598,6097.84326,80.840,
5019.36328,662.598,6097.93506,81.840,
5019.45459,662.598,6098.02637,81.840,
5019.54639,663.598,6098.11816,81.840,
5019.63770,662.598,6098.20947,82.840,
5019.72900,662.598,6098.30127,82.840,
5019.82080,662.598,6098.39258,82.840,
5019.91211,662.598,6098.48389,82.840,
5020.00391,662.598,6098.57568,82.840,
5020.09521,662.598,6098.66699,82.840,
5020.18701,661.598,6098.75879,82.840,
5020.27832,661.598,6098.85010,82.840,
5020.36963,661.598,6098.94189,82.840,
5020.46143,661.598,6099.03320,82.840,
5020.55273,660.598,6099.12500,82.840,
5020.64453,661.598,6099.21631,82.840,
5020.73584,660.598,6099.30762,82.840,
5020.82764,659.598,6099.39941,82.840,
5020.91895,659.598,6099.49072,81.840,
5021.01074,660.598,6099.58252,82.840,
5021.10205,659.598,6099.67383,82.840,
5021.19336,659.598,6099.76563,82.840,
5021.28516,658.598,6099.85693,83.840,
5021.37646,657.598,6099.94824,82.840,
5021.46826,655.598,6100.04004,82.840,
5021.55957,655.598,6100.13135,82.840,
5021.65137,654.598,6100.22314,82.840,
5021.74268,654.598,6100.31445,82.840,
5021.83398,654.598,6100.40625,82.840,
5021.92578,654.598,6100.49756,82.840,
5022.01709,654.598,6100.58887,82.840,
5022.10889,654.598,6100.68066,82.840,
5022.20020,654.598,6100.77197,82.840,
5022.29199,655.598,6100.86377,82.840,
5022.38330,655.598,6100.95508,82.840,
5022.47461,655.598,6101.04688,81.840,
5022.56641,655.598,6101.13818,82.840,
5022.65771,655.598,6101.22998,81.840,
5022.74951,655.598,6101.32129,82.840,
5022.84082,656.598,6101.41260,82.840,
5022.93262,656.598,6101.50439,81.840,
5023.02393,656.598,6101.59570,81.840,
5023.11572,656.598,6101.68750,81.840,
5023.20703,656.598,6101.77881,82.840,
5023.29834,656.598,6101.87061,81.840,
5023.39014,656.598,6101.96191,81.840,
5023.48145,656.598,6102.05322,81.840,
5023.57324,657.598,6102.14502,81.840,
5023.66455,656.598,6102.23633,81.840,
5023.75635,656.598,6102.32813,81.840,
5023.84766,656.598,6102.41943,81.840,
5023.93896,656.598,6102.51123,81.840,
5024.03076,655.598,6102.60254,81.840,
5024.12207,656.598,6102.69385,81.840,
5024.21387,656.598,6102.78564,81.840,
5024.30518,656.598,6102.87695,81.840,
5024.39697,655.598,6102.96875,81.840,
5024.48828,655.598,6103.06006,81.840,
5024.57959,655.598,6103.15186,80.840,
5024.67139,655.598,6103.24316,81.840,
5024.76270,655.598,6103.33496,80.840,
5024.85449,655.598,6103.42627,80.840,
5024.94580,655.598,6103.51758,80.840,
5025.03760,655.598,6103.60938,80.840,
5025.12891,654.598,6103.70068,80.840,
5025.22070,654.598,6103.79248,80.840,
5025.31201,654.598,6103.88379,80.840,
5025.40332,654.598,6103.97559,80.840,
5025.49512,654.598,6104.06689,80.840,
5025.58643,654.598,6104.15820,80.840,
5025.67822,654.598,6104.25000,80.840,
5025.76953,653.598,6104.34131,80.840,
5025.86133,654.598,6104.43311,81.840,
5025.95264,653.598,6104.52441,80.840,
5026.04395,653.598,6104.61621,80.840,
5026.13574,653.598,6104.70752,80.840,
5026.22705,653.598,6104.79883,80.840,
5026.31885,653.598,6104.89063,80.840,
5026.41016,652.598,6104.98193,80.840,
5026.50195,653.598,6105.07373,79.840,
5026.59326,652.598,6105.16504,80.840,
5026.68457,653.598,6105.25684,80.840,
5026.77637,652.598,6105.34814,80.840,
5026.86768,653.598,6105.43945,79.840,
5026.95947,652.598,6105.53125,79.840,
5027.05078,652.598,6105.62256,80.840,
5027.14258,652.598,6105.71436,81.840,
5027.23389,652.598,6105.80566,80.840,
5027.32568,652.598,6105.89746,79.840,
5027.41699,652.598,6105.98877,80.840,
5027.50830,652.598,6106.08057,79.840,
5027.60010,651.598,6106.17188,79.840,
5027.69141,651.598,6106.26318,80.840,
5027.78320,651.598,6106.35498,79.840,
5027.87451,651.598,6106.44629,79.840,
5027.96631,652.598,6106.53809,80.840,
5028.05762,651.598,6106.62939,79.840,
5028.14893,651.598,6106.72119,80.840,
5028.24072,651.598,6106.81250,80.840,
5028.33203,651.598,6106.90381,80.840,
5028.42383,651.598,6106.99561,80.840,
5028.51514,651.598,6107.08691,79.840,
5028.60693,651.598,6107.17871,80.840,
5028.69824,651.598,6107.27002,80.840,
5028.78955,650.598,6107.36182,79.840,
5028.88135,650.598,6107.45313,79.840,
5028.97266,649.598,6107.54443,79.840,
5029.06445,650.598,6107.63623,79.840,
5029.15576,649.598,6107.72754,80.840,
5029.24756,650.598,6107.81934,79.840,
5029.33887,650.598,6107.91064,79.840,
5029.43066,650.598,6108.00244,79.840,
5029.52197,650.598,6108.09375,79.840,
5029.61328,650.598,6108.18555,79.840,
5029.70508,650.598,6108.27686,79.840,
5029.79639,649.598,6108.36816,79.840,
5029.88818,650.598,6108.45996,79.840,
5029.97949,649.598,6108.55127,79.840,
5030.07129,649.598,6108.64307,79.840,
5030.16260,649.598,6108.73438,79.840,
5030.25391,649.598,6108.82617,79.840,
5030.34570,648.598,6108.91748,79.840,
5030.43701,649.598,6109.00879,79.840,
5030.52881,648.598,6109.10059,78.840,
5030.62012,648.598,6109.19189,79.840,
5030.71191,648.598,6109.28369,79.840,
5030.80322,648.598,6109.37500,78.840,
5030.89453,648.598,6109.46680,78.840,
5030.98633,648.598,6109.55811,78.840,
5031.07764,648.598,6109.64941,78.840,
5031.16943,648.598,6109.74121,79.840,
5031.26074,648.598,6109.83252,78.840,
5031.35254,648.598,6109.92432,78.840,
5031.44385,648.598,6110.01563,78.840,
5031.53516,648.598,6110.10742,79.840,
5031.62695,647.598,6110.19873,79.840,
5031.71826,647.598,6110.29053,78.840,
5031.81006,647.598,6110.38184,78.840,
5031.90137,647.598,6110.47314,78.840,
5031.99316,647.598,6110.56494,78.840,
5032.08447,646.598,6110.65625,78.840,
5032.17627,646.598,6110.74805,78.840,
5032.26758,647.598,6110.83936,78.840,
5032.35889,648.598,6110.93115,78.840,
5032.45068,646.598,6111.02246,78.840,
5032.54199,646.598,6111.11377,78.840,
5032.63379,647.598,6111.20557,78.840,
5032.72510,646.598,6111.29688,78.840,
5032.81689,646.598,6111.38867,78.840,
5032.90820,646.598,6111.47998,78.840,
5032.99951,646.598,6111.57178,79.840,
5033.09131,645.598,6111.66309,78.840,
5033.18262,645.598,6111.75439,78.840,
5033.27441,646.598,6111.84619,78.840,
5033.36572,646.598,6111.93750,78.840,
5033.45752,645.598,6112.02930,78.840,
5033.54883,645.598,6112.12061,78.840,
5033.64014,645.598,6112.21240,78.840,
5033.73193,645.598,6112.30371,77.840,
5033.82324,645.598,6112.39551,77.840,
5033.91504,645.598,6112.48682,77.840,
5034.00635,645.598,6112.57813,76.840,
5034.09814,645.598,6112.66992,76.840,
5034.18945,645.598,6112.76123,77.840,
5034.28125,644.598,6112.85303,77.840,
5034.37256,644.598,6112.94434,76.840,
5034.46387,645.598,6113.03613,77.840,
5034.55566,644.598,6113.12744,76.840,
5034.64697,643.598,6113.21875,76.840,
5034.73877,644.598,6113.31055,76.840,
5034.83008,643.598,6113.40186,76.840,
5034.92188,643.598,6113.49365,76.840,
5035.01318,644.598,6113.58496,76.840,
5035.10449,643.598,6113.67676,77.840,
5035.19629,643.598,6113.76807,76.840,
5035.28760,644.598,6113.85938,76.840,
5035.37939,643.598,6113.95117,76.840,
5035.47070,644.598,6114.04248,76.840,
5035.56250,643.598,6114.13428,76.840,
5035.65381,643.598,6114.22559,77.840,
5035.74512,643.598,6114.31738,76.840,
5035.83691,643.598,6114.40869,76.840,
5035.92822,643.598,6114.50049,76.840,
5036.02002,643.598,6114.59180,77.840,
5036.11133,642.598,6114.68311,78.840,
5036.20313,643.598,6114.77490,77.840,
5036.29443,642.598,6114.86621,77.840,
5036.38623,642.598,6114.95801,78.840,
5036.47754,642.598,6115.04932,78.840,
5036.56885,642.598,6115.14111,78.840,
5036.66064,642.598,6115.23242,78.840,
5036.75195,642.598,6115.32373,77.840,
5036.84375,642.598,6115.41553,77.840,
5036.93506,642.598,6115.50684,77.840,
5037.02686,641.598,6115.59863,77.840,
5037.11816,641.598,6115.68994,77.840,
5037.20947,641.598,6115.78174,76.840,
5037.30127,640.598,6115.87305,77.840,
5037.39258,639.598,6115.96436,77.840,
5037.48438,639.598,6116.05615,77.840,
5037.57568,639.598,6116.14746,76.840,
5037.66748,638.598,6116.23926,76.840,
5037.75879,638.598,6116.33057,76.840,
5037.85010,639.598,6116.42236,76.840,
5037.94189,639.598,6116.51367,76.840,
5038.03320,639.598,6116.60498,76.840,
5038.12500,639.598,6116.69678,76.840,
5038.21631,639.598,6116.78809,76.840,
5038.30811,639.598,6116.87988,75.840,
5038.39941,639.598,6116.97119,76.840,
5038.49121,639.598,6117.06299,76.840,
5038.58252,639.598,6117.15430,76.840,
5038.67383,639.598,6117.24609,76.840,
5038.76563,639.598,6117.33740,76.840,
5038.85693,639.598,6117.42871,76.840,
5038.94873,639.598,6117.52051,76.840,
5039.04004,639.598,6117.61182,76.840,
5039.13184,639.598,6117.70361,76.840,
5039.22314,639.598,6117.79492,76.840,
5039.31445,639.598,6117.88672,75.840,
5039.40625,639.598,6117.97803,75.840,
5039.49756,639.598,6118.06934,76.840,
5039.58936,640.598,6118.16113,75.840,
5039.68066,641.598,6118.25244,75.840,
5039.77246,640.598,6118.34424,75.840,
5039.86377,641.598,6118.43555,75.840,
5039.95508,641.598,6118.52734,75.840,
5040.04688,641.598,6118.61865,75.840,
5040.13818,641.598,6118.70996,75.840,
5040.22998,641.598,6118.80176,75.840,
5040.32129,641.598,6118.89307,76.840,
5040.41309,641.598,6118.98486,75.840,
5040.50439,640.598,6119.07617,75.840,
5040.59619,640.598,6119.16797,75.840,
5040.68750,640.598,6119.25928,75.840,
5040.77881,640.598,6119.35107,75.840,
5040.87061,639.598,6119.44238,75.840,
5040.96191,639.598,6119.53369,75.840,
5041.05371,639.598,6119.62549,75.840,
5041.14502,640.598,6119.71680,74.840,
5041.23682,638.598,6119.80859,75.840,
5041.32813,638.598,6119.89990,75.840,
5041.41943,638.598,6119.99170,75.840,
5041.51123,638.598,6120.08301,75.840,
5041.60254,637.598,6120.17432,75.840,
5041.69434,637.598,6120.26611,75.840,
5041.78564,637.598,6120.35742,75.840,
5041.87744,636.598,6120.44922,75.840,
5041.96875,636.598,6120.54053,74.840,
5042.06006,636.598,6120.63232,75.840,
5042.15186,635.598,6120.72363,74.840,
5042.24316,636.598,6120.81494,75.840,
5042.33496,636.598,6120.90674,74.840,
5042.42627,636.598,6120.99805,74.840,
5042.51807,636.598,6121.08984,74.840,
5042.60938,636.598,6121.18115,74.840,
5042.70117,635.598,6121.27295,74.840,
5042.79248,635.598,6121.36426,74.840,
5042.88379,635.598,6121.45605,74.840,
5042.97559,636.598,6121.54736,73.840,
5043.06689,635.598,6121.63867,74.840,
5043.15869,635.598,6121.73047,74.840,
5043.25000,635.598,6121.82178,74.840,
5043.34180,634.598,6121.91357,74.840,
5043.43311,634.598,6122.00488,74.840,
5043.52441,634.598,6122.09668,73.840,
5043.61621,634.598,6122.18799,73.840,
5043.70752,634.598,6122.27930,74.840,
5043.79932,634.598,6122.37109,73.840,
5043.89063,634.598,6122.46240,74.840,
5043.98242,634.598,6122.55420,74.840,
5044.07373,634.598,6122.64551,73.840,
5044.16504,634.598,6122.73730,73.840,
5044.25684,634.598,6122.82861,73.840,
5044.34814,633.598,6122.91992,73.840,
5044.43994,633.598,6123.01172,73.840,
5044.53125,633.598,6123.10303,73.840,
5044.62305,633.598,6123.19482,73.840,
5044.71436,633.598,6123.28613,74.840,
5044.80566,633.598,6123.37793,73.840,
5044.89746,633.598,6123.46924,73.840,
5044.98877,633.598,6123.56104,73.840,
5045.08057,633.598,6123.65234,73.840,
5045.17188,633.598,6123.74365,73.840,
5045.26367,632.598,6123.83545,73.840,
5045.35498,633.598,6123.92676,73.840,
5045.44678,633.598,6124.01855,73.840,
5045.53809,633.598,6124.10986,73.840,
5045.62939,632.598,6124.20166,73.840,
5045.72119,632.598,6124.29297,72.840,
5045.81250,631.598,6124.38428,73.840,
5045.90430,632.598,6124.47607,73.840,
5045.99561,632.598,6124.56738,73.840,
5046.08740,632.598,6124.65918,72.840,
5046.17871,631.598,6124.75049,74.840,
5046.27002,631.598,6124.84229,72.840,
5046.36182,631.598,6124.93359,73.840,
5046.45313,631.598,6125.02490,73.840,
5046.54492,631.598,6125.11670,73.840,
5046.63623,630.598,6125.20801,73.840,
5046.72803,631.598,6125.29980,73.840,
5046.81934,631.598,6125.39111,73.840,
5046.91064,631.598,6125.48291,72.840,
5047.00244,632.598,6125.57422,72.840,
5047.09375,631.598,6125.66602,73.840,
5047.18555,631.598,6125.75732,72.840,
5047.27686,631.598,6125.84863,73.840,
5047.36865,631.598,6125.94043,73.840,
5047.45996,631.598,6126.03174,73.840,
5047.55176,631.598,6126.12354,73.840,
5047.64307,630.598,6126.21484,74.840,
5047.73438,630.598,6126.30664,73.840,
5047.82617,630.598,6126.39795,73.840,
5047.91748,630.598,6126.48926,73.840,
5048.00928,629.598,6126.58105,73.840,
5048.10059,630.598,6126.67236,73.840,
5048.19238,630.598,6126.76416,72.840,
5048.28369,629.598,6126.85547,72.840,
5048.37500,629.598,6126.94727,72.840,
5048.46680,630.598,6127.03857,72.840,
5048.55811,630.598,6127.12988,72.840,
5048.64990,629.598,6127.22168,73.840,
5048.74121,629.598,6127.31299,72.840,
5048.83301,629.598,6127.40479,72.840,
5048.92432,629.598,6127.49609,72.840,
5049.01563,629.598,6127.58789,72.840,
5049.10742,628.598,6127.67920,72.840,
5049.19873,629.598,6127.77100,72.840,
5049.29053,628.598,6127.86230,73.840,
5049.38184,628.598,6127.95361,72.840,
5049.47363,628.598,6128.04541,72.840,
5049.56494,628.598,6128.13672,72.840,
5049.65674,628.598,6128.22852,72.840,
5049.74805,628.598,6128.31982,71.840,
5049.83936,627.598,6128.41162,71.840,
5049.93115,628.598,6128.50293,72.840,
5050.02246,627.598,6128.59424,72.840,
5050.11426,627.598,6128.68604,72.840,
5050.20557,627.598,6128.77734,72.840,
5050.29736,627.598,6128.86914,71.840,
5050.38867,627.598,6128.96045,72.840,
5050.47998,627.598,6129.05225,72.840,
5050.57178,627.598,6129.14355,72.840,
5050.66309,627.598,6129.23486,72.840,
5050.75488,626.598,6129.32666,72.840,
5050.84619,626.598,6129.41797,71.840,
5050.93799,626.598,6129.50977,71.840,
5051.02930,626.598,6129.60107,71.840,
5051.12061,626.598,6129.69287,71.840,
5051.21240,626.598,6129.78418,71.840,
5051.30371,626.598,6129.87549,71.840,
5051.39551,626.598,6129.96729,71.840,
5051.48682,626.598,6130.05859,71.840,
5051.57861,626.598,6130.15039,71.840,
5051.66992,625.598,6130.24170,71.840,
5051.76172,626.598,6130.33350,71.840,
5051.85303,626.598,6130.42480,71.840,
5051.94434,625.598,6130.51660,70.840,
5052.03613,626.598,6130.60791,71.840,
5052.12744,625.598,6130.69922,70.840,
5052.21924,625.598,6130.79102,70.840,
5052.31055,625.598,6130.88232,70.840,
5052.40234,625.598,6130.97412,70.840,
5052.49365,624.598,6131.06543,69.840,
5052.58496,625.598,6131.15723,70.840,
5052.67676,625.598,6131.24854,70.840,
5052.76807,624.598,6131.33984,69.840,
5052.85986,625.598,6131.43164,69.840,
5052.95117,624.598,6131.52295,69.840,
5053.04297,624.598,6131.61475,69.840,
5053.13428,624.598,6131.70605,69.840,
5053.22559,624.598,6131.79785,69.840,
5053.31738,624.598,6131.88916,69.840,
5053.40869,624.598,6131.98047,69.840,
5053.50049,624.598,6132.07227,70.840,
5053.59180,624.598,6132.16357,69.840,
5053.68359,623.598,6132.25537,69.840,
5053.77490,623.598,6132.34668,70.840,
5053.86670,623.598,6132.43848,70.840,
5053.95801,623.598,6132.52979,70.840,
5054.04932,623.598,6132.62158,71.840,
5054.14111,623.598,6132.71289,71.840,
5054.23242,623.598,6132.80420,72.840,
5054.32422,624.598,6132.89600,72.840,
5054.41553,623.598,6132.98730,72.840,
5054.50732,623.598,6133.07910,72.840,
5054.59863,623.598,6133.17041,73.840,
5054.68994,623.598,6133.26221,72.840,
5054.78174,623.598,6133.35352,72.840,
5054.87305,623.598,6133.44482,72.840,
5054.96484,622.598,6133.53662,73.840,
5055.05615,623.598,6133.62793,72.840,
5055.14795,623.598,6133.71973,71.840,
5055.23926,624.598,6133.81104,71.840,
5055.33057,624.598,6133.90283,71.840,
5055.42236,625.598,6133.99414,71.840,
5055.51367,625.598,6134.08545,70.840,
5055.60547,625.598,6134.17725,70.840,
5055.69678,625.598,6134.26855,70.840,
5055.78857,626.598,6134.36035,70.840,
5055.87988,625.598,6134.45166,70.840,
5055.97168,625.598,6134.54346,70.840,
5056.06299,625.598,6134.63477,69.840,
5056.15430,624.598,6134.72656,69.840,
5056.24609,624.598,6134.81787,69.840,
5056.33740,623.598,6134.90918,69.840,
5056.42920,623.598,6135.00098,70.840,
5056.52051,623.598,6135.09229,69.840,
5056.61230,622.598,6135.18408,69.840,
5056.70361,622.598,6135.27539,69.840,
5056.79492,621.598,6135.36719,69.840,
5056.88672,621.598,6135.45850,69.840,
5056.97803,621.598,6135.54980,69.840,
5057.06982,621.598,6135.64160,69.840,
5057.16113,620.598,6135.73291,69.840,
5057.25293,621.598,6135.82471,68.840,
5057.34424,620.598,6135.91602,68.840,
5057.43555,620.598,6136.00781,69.840,
5057.52734,620.598,6136.09912,69.840,
5057.61865,620.598,6136.19043,68.840,
5057.71045,620.598,6136.28223,69.840,
5057.80176,620.598,6136.37354,69.840,
5057.89355,620.598,6136.46533,69.840,
5057.98486,620.598,6136.55664,69.840,
5058.07617,620.598,6136.64844,68.840,
5058.16797,620.598,6136.73975,68.840,
5058.25928,619.598,6136.83154,68.840,
5058.35107,619.598,6136.92285,69.840,
5058.44238,619.598,6137.01416,68.840,
5058.53418,619.598,6137.10596,68.840,
5058.62549,619.598,6137.19727,68.840,
5058.71729,620.598,6137.28906,68.840,
5058.80859,619.598,6137.38037,68.840,
5058.89990,619.598,6137.47217,68.840,
5058.99170,619.598,6137.56348,68.840,
5059.08301,619.598,6137.65479,68.840,
5059.17480,618.598,6137.74658,68.840,
5059.26611,618.598,6137.83789,68.840,
5059.35791,618.598,6137.92969,69.840,
5059.44922,618.598,6138.02100,68.840,
5059.54053,618.598,6138.11279,67.840,
5059.63232,618.598,6138.20410,68.840,
5059.72363,618.598,6138.29541,68.840,
5059.81543,617.598,6138.38721,68.840,
5059.90674,617.598,6138.47852,68.840,
5059.99854,617.598,6138.57031,67.840,
5060.08984,617.598,6138.66162,68.840,
5060.18115,618.598,6138.75342,67.840,
5060.27295,617.598,6138.84473,68.840,
5060.36426,617.598,6138.93652,68.840,
5060.45605,617.598,6139.02783,68.840,
5060.54736,617.598,6139.11914,68.840,
5060.63916,617.598,6139.21094,67.840,
5060.73047,616.598,6139.30225,67.840,
5060.82227,617.598,6139.39404,68.840,
5060.91357,617.598,6139.48535,68.840,
5061.00488,616.598,6139.57715,67.840,
5061.09668,616.598,6139.66846,67.840,
5061.18799,616.598,6139.75977,68.840,
5061.27979,616.598,6139.85156,67.840,
5061.37109,616.598,6139.94287,67.840,
5061.46289,616.598,6140.03467,67.840,
5061.55420,616.598,6140.12598,67.840,
5061.64551,616.598,6140.21777,67.840,
5061.73730,616.598,6140.30908,67.840,
5061.82861,615.598,6140.40039,67.840,
5061.92041,615.598,6140.49219,67.840,
5062.01172,615.598,6140.58350,67.840,
5062.10352,615.598,6140.67529,67.840,
5062.19482,615.598,6140.76660,67.840,
5062.28613,615.598,6140.85840,67.840,
5062.37793,615.598,6140.94971,67.840,
5062.46924,615.598,6141.04150,67.840,
5062.56104,614.598,6141.13281,67.840,
5062.65234,614.598,6141.22412,67.840,
5062.74414,615.598,6141.31592,67.840,
5062.83545,614.598,6141.40723,66.840,
5062.92725,614.598,6141.49902,67.840,
5063.01855,614.598,6141.59033,67.840,
5063.10986,614.598,6141.68213,67.840,
5063.20166,613.598,6141.77344,67.840,
5063.29297,614.598,6141.86475,67.840,
5063.38477,614.598,6141.95654,67.840,
5063.47607,613.598,6142.04785,66.840,
5063.56787,613.598,6142.13965,66.840,
5063.65918,613.598,6142.23096,67.840,
5063.75049,613.598,6142.32275,67.840,
5063.84229,613.598,6142.41406,67.840,
5063.93359,613.598,6142.50537,66.840,
5064.02539,613.598,6142.59717,66.840,
5064.11670,612.598,6142.68848,66.840,
5064.20850,612.598,6142.78027,66.840,
5064.29980,612.598,6142.87158,67.840,
5064.39111,613.598,6142.96338,66.840,
5064.48291,612.598,6143.05469,66.840,
5064.57422,613.598,6143.14600,66.840,
5064.66602,613.598,6143.23779,66.840,
5064.75732,612.598,6143.32910,66.840,
5064.84912,612.598,6143.42090,66.840,
5064.94043,612.598,6143.51221,66.840,
5065.03223,612.598,6143.60400,66.840,
5065.12354,612.598,6143.69531,66.840,
5065.21484,612.598,6143.78711,67.840,
5065.30664,612.598,6143.87842,66.840,
5065.39795,612.598,6143.96973,66.840,
5065.48975,611.598,6144.06152,66.840,
5065.58105,612.598,6144.15283,66.840,
5065.67285,612.598,6144.24463,66.840,
5065.76416,611.598,6144.33594,66.840,
5065.85547,611.598,6144.42773,66.840,
5065.94727,611.598,6144.51904,65.840,
5066.03857,612.598,6144.61035,66.840,
5066.13037,611.598,6144.70215,65.840,
5066.22168,611.598,6144.79346,65.840,
5066.31348,610.598,6144.88525,65.840,
5066.40479,611.598,6144.97656,66.840,
5066.49609,611.598,6145.06836,66.840,
5066.58789,610.598,6145.15967,65.840,
5066.67920,610.598,6145.25098,66.840,
5066.77100,610.598,6145.34277,65.840,
5066.86230,609.598,6145.43408,65.840,
5066.95410,610.598,6145.52588,66.840,
5067.04541,610.598,6145.61719,65.840,
5067.13721,609.598,6145.70898,65.840,
5067.22852,609.598,6145.80029,65.840,
5067.31982,610.598,6145.89209,65.840,
5067.41162,609.598,6145.98340,65.840,
5067.50293,610.598,6146.07471,64.840,
5067.59473,609.598,6146.16650,65.840,
5067.68604,610.598,6146.25781,65.840,
5067.77783,609.598,6146.34961,65.840,
5067.86914,609.598,6146.44092,65.840,
5067.96045,609.598,6146.53271,65.840,
5068.05225,609.598,6146.62402,65.840,
5068.14355,609.598,6146.71533,65.840,
5068.23535,609.598,6146.80713,65.840,
5068.32666,608.598,6146.89844,65.840,
5068.41846,608.598,6146.99023,65.840,
5068.50977,608.598,6147.08154,65.840,
5068.60107,608.598,6147.17334,65.840,
5068.69287,608.598,6147.26465,64.840,
5068.78418,608.598,6147.35596,65.840,
5068.87598,608.598,6147.44775,65.840,
5068.96729,609.598,6147.53906,65.840,
5069.05908,608.598,6147.63086,64.840,
5069.15039,608.598,6147.72217,64.840,
5069.24170,607.598,6147.81396,65.840,
5069.33350,608.598,6147.90527,65.840,
5069.42480,608.598,6147.99707,64.840,
5069.51660,608.598,6148.08838,65.840,
5069.60791,607.598,6148.17969,65.840,
5069.69971,608.598,6148.27148,66.840,
5069.79102,607.598,6148.36279,66.840,
5069.88281,607.598,6148.45459,66.840,
5069.97412,606.598,6148.54590,66.840,
5070.06543,607.598,6148.63770,66.840,
5070.15723,607.598,6148.72900,67.840,
5070.24854,606.598,6148.82031,66.840,
5070.34033,606.598,6148.91211,67.840,
5070.43164,607.598,6149.00342,66.840,
5070.52344,606.598,6149.09521,66.840,
5070.61475,605.598,6149.18652,66.840,
5070.70605,606.598,6149.27832,66.840,
5070.79785,606.598,6149.36963,66.840,
5070.88916,605.598,6149.46094,66.840,
5070.98096,606.598,6149.55273,65.840,
5071.07227,605.598,6149.64404,65.840,
5071.16406,605.598,6149.73584,65.840,
5071.25537,605.598,6149.82715,65.840,
5071.34668,605.598,6149.91895,65.840,
5071.43848,605.598,6150.01025,64.840,
5071.52979,605.598,6150.10205,65.840,
5071.62158,605.598,6150.19336,64.840,
5071.71289,605.598,6150.28467,64.840,
5071.80469,605.598,6150.37646,64.840,
5071.89600,605.598,6150.46777,64.840,
5071.98779,605.598,6150.55957,63.840,
5072.07910,604.598,6150.65088,63.840,
5072.17041,605.598,6150.74268,62.840,
5072.26221,604.598,6150.83398,62.840,
5072.35352,604.598,6150.92529,61.840,
5072.44531,604.598,6151.01709,60.840,
5072.53662,604.598,6151.10840,60.840,
5072.62842,604.598,6151.20020,58.840,
5072.71973,603.598,6151.29150,59.840,
5072.81104,603.598,6151.38330,59.840,
5072.90283,602.598,6151.47461,59.840,
5072.99414,602.598,6151.56592,59.840,
5073.08594,602.598,6151.65771,59.840,
5073.17725,602.598,6151.74902,60.840,
5073.26904,602.598,6151.84082,60.840,
5073.36035,602.598,6151.93213,60.840,
5073.45166,602.598,6152.02393,61.840,
5073.54346,601.598,6152.11523,61.840,
5073.63477,602.598,6152.20703,61.840,
5073.72656,602.598,6152.29834,61.840,
5073.81787,602.598,6152.38965,61.840,
5073.90967,602.598,6152.48145,61.840,
5074.00098,602.598,6152.57275,63.840,
5074.09277,603.598,6152.66455,62.840,
5074.18408,602.598,6152.75586,63.840,
5074.27539,602.598,6152.84766,63.840,
5074.36719,602.598,6152.93896,63.840,
5074.45850,602.598,6153.03027,62.840,
5074.55029,602.598,6153.12207,62.840,
5074.64160,602.598,6153.21338,63.840,
5074.73340,602.598,6153.30518,62.840,
5074.82471,603.598,6153.39648,62.840,
5074.91602,602.598,6153.48828,62.840,
5075.00781,602.598,6153.57959,62.840,
5075.09912,602.598,6153.67090,63.840,
5075.19092,603.598,6153.76270,62.840,
5075.28223,603.598,6153.85400,62.840,
5075.37402,603.598,6153.94580,62.840,
5075.46533,604.598,6154.03711,63.840,
5075.55664,604.598,6154.12891,62.840,
5075.64844,604.598,6154.22021,62.840,
5075.73975,604.598,6154.31152,62.840,
5075.83154,604.598,6154.40332,62.840,
5075.92285,604.598,6154.49463,62.840,
5076.01465,604.598,6154.58643,62.840,
5076.10596,604.598,6154.67773,62.840,
5076.19775,604.598,6154.76953,63.840,
5076.28906,604.598,6154.86084,62.840,
5076.38037,603.598,6154.95264,62.840,
5076.47217,603.598,6155.04395,62.840,
5076.56348,603.598,6155.13525,62.840,
5076.65527,602.598,6155.22705,62.840,
5076.74658,601.598,6155.31836,62.840,
5076.83838,602.598,6155.41016,62.840,
5076.92969,601.598,6155.50146,63.840,
5077.02100,601.598,6155.59326,62.840,
5077.11279,600.598,6155.68457,62.840,
5077.20410,600.598,6155.77588,62.840,
5077.29590,599.598,6155.86768,62.840,
5077.38721,599.598,6155.95898,62.840,
5077.47900,599.598,6156.05078,62.840,
5077.57031,599.598,6156.14209,62.840,
5077.66162,599.598,6156.23389,61.840,
5077.75342,599.598,6156.32520,61.840,
5077.84473,598.598,6156.41650,61.840,
5077.93652,599.598,6156.50830,61.840,
5078.02783,598.598,6156.59961,61.840,
5078.11963,598.598,6156.69141,61.840,
5078.21094,598.598,6156.78271,61.840,
5078.30273,598.598,6156.87451,61.840,
5078.39404,598.598,6156.96582,62.840,
5078.48535,597.598,6157.05762,61.840,
5078.57715,598.598,6157.14893,61.840,
5078.66846,597.598,6157.24023,61.840,
5078.76025,597.598,6157.33203,61.840,
5078.85156,597.598,6157.42334,61.840,
5078.94336,597.598,6157.51514,61.840,
5079.03467,597.598,6157.60645,61.840,
5079.12598,597.598,6157.69824,61.840,
5079.21777,598.598,6157.78955,61.840,
5079.30908,597.598,6157.88086,61.840,
5079.40088,597.598,6157.97266,60.840,
5079.49219,597.598,6158.06396,60.840,
5079.58398,596.598,6158.15576,60.840,
5079.67529,596.598,6158.24707,60.840,
5079.76660,597.598,6158.33887,60.840,
5079.85840,596.598,6158.43018,61.840,
5079.94971,596.598,6158.52148,60.840,
5080.04150,596.598,6158.61328,60.840,
5080.13281,596.598,6158.70459,61.840,
5080.22461,596.598,6158.79639,60.840,
5080.31592,595.598,6158.88770,60.840,
5080.40771,596.598,6158.97949,60.840,
5080.49902,596.598,6159.07080,61.840,
5080.59033,595.598,6159.16260,60.840,
5080.68213,596.598,6159.25391,60.840,
5080.77344,595.598,6159.34521,60.840,
5080.86523,595.598,6159.43701,60.840,
5080.95654,595.598,6159.52832,60.840,
5081.04834,595.598,6159.62012,60.840,
5081.13965,595.598,6159.71143,60.840,
5081.23096,594.598,6159.80322,60.840,
5081.32275,595.598,6159.89453,60.840,
5081.41406,595.598,6159.98584,60.840,
5081.50586,594.598,6160.07764,60.840,
5081.59717,594.598,6160.16895,60.840,
5081.68896,594.598,6160.26074,60.840,
5081.78027,594.598,6160.35205,60.840,
5081.87158,594.598,6160.44385,60.840,
5081.96338,594.598,6160.53516,60.840,
5082.05469,594.598,6160.62646,60.840,
5082.14648,595.598,6160.71826,60.840,
5082.23779,594.598,6160.80957,59.840,
5082.32959,594.598,6160.90137,60.840,
5082.42090,594.598,6160.99268,59.840,
5082.51221,594.598,6161.08447,60.840,
5082.60400,594.598,6161.17578,59.840,
5082.69531,593.598,6161.26758,59.840,
5082.78711,593.598,6161.35889,60.840,
5082.87842,594.598,6161.45020,60.840,
5082.97021,593.598,6161.54199,60.840,
5083.06152,593.598,6161.63330,59.840,
5083.15332,593.598,6161.72510,60.840,
5083.24463,593.598,6161.81641,59.840,
5083.33594,593.598,6161.90820,59.840,
5083.42773,593.598,6161.99951,59.840,
5083.51904,593.598,6162.09082,60.840,
5083.61084,593.598,6162.18262,59.840,
5083.70215,592.598,6162.27393,59.840,
5083.79395,593.598,6162.36572,59.840,
5083.88525,592.598,6162.45703,59.840,
5083.97656,592.598,6162.54883,59.840,
5084.06836,592.598,6162.64014,59.840,
5084.15967,591.598,6162.73145,59.840,
5084.25146,592.598,6162.82324,59.840,
5084.34277,591.598,6162.91455,59.840,
5084.43457,591.598,6163.00635,59.840,
5084.52588,591.598,6163.09766,58.840,
5084.61719,592.598,6163.18945,59.840,
5084.70898,591.598,6163.28076,59.840,
5084.80029,591.598,6163.37256,59.840,
5084.89209,591.598,6163.46387,58.840,
5084.98340,591.598,6163.55518,59.840,
5085.07520,591.598,6163.64697,59.840,
5085.16650,591.598,6163.73828,59.840,
5085.25830,590.598,6163.83008,58.840,
5085.34961,590.598,6163.92139,59.840,
5085.44092,591.598,6164.01318,59.840,
5085.53271,590.598,6164.10449,58.840,
5085.62402,590.598,6164.19580,59.840,
5085.71582,590.598,6164.28760,59.840,
5085.80713,590.598,6164.37891,58.840,
5085.89893,590.598,6164.47070,59.840,
5085.99023,589.598,6164.56201,58.840,
5086.08154,589.598,6164.65381,59.840,
5086.17334,589.598,6164.74512,58.840,
5086.26465,590.598,6164.83643,59.840,
5086.35645,590.598,6164.92822,59.840,
5086.44775,589.598,6165.01953,59.840,
5086.53955,590.598,6165.11133,59.840,
5086.63086,589.598,6165.20264,58.840,
5086.72217,589.598,6165.29443,58.840,
5086.81396,589.598,6165.38574,58.840,
5086.90527,589.598,6165.47754,58.840,
5086.99707,588.598,6165.56885,58.840,
5087.08838,588.598,6165.66016,59.840,
5087.18018,588.598,6165.75195,58.840,
5087.27148,588.598,6165.84326,58.840,
5087.36328,588.598,6165.93506,58.840,
5087.45459,588.598,6166.02637,58.840,
5087.54590,588.598,6166.11816,58.840,
5087.63770,588.598,6166.20947,58.840,
5087.72900,588.598,6166.30078,57.840,
5087.82080,588.598,6166.39258,57.840,
5087.91211,588.598,6166.48389,57.840,
5088.00391,588.598,6166.57568,57.840,
5088.09521,587.598,6166.66699,57.840,
5088.18652,587.598,6166.75879,57.840,
5088.27832,587.598,6166.85010,57.840,
5088.36963,587.598,6166.94141,57.840,
5088.46143,587.598,6167.03320,57.840,
5088.55273,587.598,6167.12451,57.840,
5088.64453,587.598,6167.21631,58.840,
5088.73584,587.598,6167.30762,58.840,
5088.82715,587.598,6167.39941,58.840,
5088.91895,587.598,6167.49072,58.840,
5089.01025,587.598,6167.58203,58.840,
5089.10205,587.598,6167.67383,58.840,
5089.19336,586.598,6167.76514,58.840,
5089.28516,586.598,6167.85693,58.840,
5089.37646,587.598,6167.94824,58.840,
5089.46826,587.598,6168.04004,58.840,
5089.55957,586.598,6168.13135,58.840,
5089.65088,586.598,6168.22314,58.840,
5089.74268,586.598,6168.31445,58.840,
5089.83398,586.598,6168.40576,57.840,
5089.92578,586.598,6168.49756,57.840,
5090.01709,586.598,6168.58887,58.840,
5090.10889,586.598,6168.68066,57.840,
5090.20020,585.598,6168.77197,56.840,
5090.29150,586.598,6168.86377,55.840,
5090.38330,586.598,6168.95508,54.840,
5090.47461,586.598,6169.04639,54.840,
5090.56641,586.598,6169.13818,53.840,
5090.65771,587.598,6169.22949,53.840,
5090.74951,588.598,6169.32129,53.840,
5090.84082,587.598,6169.41260,53.840,
5090.93213,587.598,6169.50439,53.840,
5091.02393,588.598,6169.59570,53.840,
5091.11523,588.598,6169.68701,53.840,
5091.20703,588.598,6169.77881,53.840,
5091.29834,587.598,6169.87012,54.840,
5091.39014,587.598,6169.96191,53.840,
5091.48145,586.598,6170.05322,54.840,
5091.57324,587.598,6170.14502,55.840,
5091.66455,586.598,6170.23633,54.840,
5091.75586,586.598,6170.32813,55.840,
5091.84766,585.598,6170.41943,56.840,
5091.93896,585.598,6170.51074,55.840,
5092.03076,585.598,6170.60254,56.840,
5092.12207,584.598,6170.69385,56.840,
5092.21387,584.598,6170.78564,56.840,
5092.30518,584.598,6170.87695,56.840,
5092.39648,584.598,6170.96875,56.840,
5092.48828,583.598,6171.06006,56.840,
5092.57959,583.598,6171.15137,56.840,
5092.67139,583.598,6171.24316,56.840,
5092.76270,581.598,6171.33447,56.840,
5092.85449,581.598,6171.42627,56.840,
5092.94580,580.598,6171.51758,56.840,
5093.03711,580.598,6171.60938,57.840,
5093.12891,579.598,6171.70068,56.840,
5093.22021,579.598,6171.79199,56.840,
5093.31201,579.598,6171.88379,57.840,
5093.40332,579.598,6171.97510,57.840,
5093.49512,580.598,6172.06689,56.840,
5093.58643,579.598,6172.15820,56.840,
5093.67822,580.598,6172.25000,56.840,
5093.76953,580.598,6172.34131,56.840,
5093.86084,581.598,6172.43311,56.840,
5093.95264,580.598,6172.52441,56.840,
5094.04395,580.598,6172.61572,56.840,
5094.13574,581.598,6172.70752,56.840,
5094.22705,580.598,6172.79883,56.840,
5094.31885,580.598,6172.89063,56.840,
5094.41016,580.598,6172.98193,56.840,
5094.50146,580.598,6173.07373,56.840,
5094.59326,580.598,6173.16504,56.840,
5094.68457,580.598,6173.25635,56.840,
5094.77637,580.598,6173.34814,55.840,
5094.86768,580.598,6173.43945,56.840,
5094.95947,580.598,6173.53125,56.840,
5095.05078,580.598,6173.62256,56.840,
5095.14209,580.598,6173.71436,56.840,
5095.23389,580.598,6173.80566,56.840,
5095.32520,581.598,6173.89697,56.840,
5095.41699,580.598,6173.98877,55.840,
5095.50830,580.598,6174.08008,55.840,
5095.60010,580.598,6174.17188,55.840,
5095.69141,580.598,6174.26318,55.840,
5095.78271,580.598,6174.35498,55.840,
5095.87451,579.598,6174.44629,56.840,
5095.96582,580.598,6174.53809,56.840,
5096.05762,579.598,6174.62939,56.840,
5096.14893,579.598,6174.72070,56.840,
5096.24072,579.598,6174.81250,55.840,
5096.33203,579.598,6174.90381,55.840,
5096.42383,579.598,6174.99561,55.840,
5096.51514,579.598,6175.08691,55.840,
5096.60645,578.598,6175.17871,55.840,
5096.69824,579.598,6175.27002,55.840,
5096.78955,579.598,6175.36133,55.840,
5096.88135,579.598,6175.45313,55.840,
5096.97266,578.598,6175.54443,55.840,
5097.06445,578.598,6175.63623,55.840,
5097.15576,578.598,6175.72754,55.840,
5097.24707,578.598,6175.81934,55.840,
5097.33887,578.598,6175.91064,55.840,
5097.43018,578.598,6176.00195,55.840,
5097.52197,578.598,6176.09375,55.840,
5097.61328,578.598,6176.18506,55.840,
5097.70508,578.598,6176.27686,55.840,
5097.79639,577.598,6176.36816,55.840,
5097.88770,577.598,6176.45996,55.840,
5097.97949,577.598,6176.55127,55.840,
5098.07080,578.598,6176.64307,55.840,
5098.16260,577.598,6176.73438,55.840,
5098.25391,577.598,6176.82568,55.840,
5098.34570,577.598,6176.91748,54.840,
5098.43701,577.598,6177.00879,55.840,
5098.52881,576.598,6177.10059,55.840,
5098.62012,577.598,6177.19189,54.840,
5098.71143,577.598,6177.28369,55.840,
5098.80322,576.598,6177.37500,54.840,
5098.89453,576.598,6177.46631,55.840,
5098.98633,576.598,6177.55811,55.840,
5099.07764,576.598,6177.64941,54.840,
5099.16943,576.598,6177.74121,54.840,
5099.26074,576.598,6177.83252,54.840,
5099.35205,576.598,6177.92432,54.840,
5099.44385,575.598,6178.01563,54.840,
5099.53516,576.598,6178.10693,54.840,
5099.62695,576.598,6178.19873,54.840,
5099.71826,576.598,6178.29004,53.840,
5099.81006,576.598,6178.38184,53.840,
5099.90137,576.598,6178.47314,54.840,
5099.99268,575.598,6178.56494,54.840,
5100.08447,576.598,6178.65625,54.840,
5100.17578,575.598,6178.74756,54.840,
5100.26758,575.598,6178.83936,54.840,
5100.35889,575.598,6178.93066,55.840,
5100.45068,575.598,6179.02246,54.840,
5100.54199,575.598,6179.11377,54.840,
5100.63379,574.598,6179.20557,54.840,
5100.72510,575.598,6179.29688,54.840,
5100.81641,575.598,6179.38867,54.840,
5100.90820,574.598,6179.47998,54.840,
5100.99951,574.598,6179.57129,54.840,
5101.09131,574.598,6179.66309,54.840,
5101.18262,575.598,6179.75439,54.840,
5101.27441,574.598,6179.84619,53.840,
5101.36572,575.598,6179.93750,54.840,
5101.45703,574.598,6180.02930,54.840,
5101.54883,574.598,6180.12061,54.840,
5101.64014,574.598,6180.21191,54.840,
5101.73193,574.598,6180.30371,53.840,
5101.82324,573.598,6180.39502,54.840,
5101.91504,574.598,6180.48682,54.840,
5102.00635,573.598,6180.57813,53.840,
5102.09766,573.598,6180.66992,53.840,
5102.18945,573.598,6180.76123,54.840,
5102.28076,573.598,6180.85254,53.840,
5102.37256,573.598,6180.94434,53.840,
5102.46387,572.598,6181.03564,53.840,
5102.55566,572.598,6181.12744,54.840,
5102.64697,573.598,6181.21875,54.840,
5102.73877,572.598,6181.31055,53.840,
5102.83008,572.598,6181.40186,53.840,
5102.92139,572.598,6181.49365,53.840,
5103.01318,572.598,6181.58496,53.840,
5103.10449,572.598,6181.67627,53.840,
5103.19629,572.598,6181.76807,53.840,
5103.28760,572.598,6181.85938,53.840,
5103.37939,571.598,6181.95117,53.840,
5103.47070,571.598,6182.04248,53.840,
5103.56201,571.598,6182.13428,52.840,
5103.65381,571.598,6182.22559,53.840,
5103.74512,571.598,6182.31689,53.840,
5103.83691,571.598,6182.40869,53.840,
5103.92822,571.598,6182.50000,53.840,
5104.02002,571.598,6182.59180,52.840,
5104.11133,571.598,6182.68311,53.840,
5104.20264,571.598,6182.77490,53.840,
5104.29443,571.598,6182.86621,52.840,
5104.38574,570.598,6182.95752,53.840,
5104.47754,571.598,6183.04932,53.840,
5104.56885,570.598,6183.14063,53.840,
5104.66064,570.598,6183.23242,52.840,
5104.75195,571.598,6183.32373,53.840,
5104.84375,570.598,6183.41553,53.840,
5104.93506,569.598,6183.50684,53.840,
5105.02637,570.598,6183.59863,53.840,
5105.11816,570.598,6183.68994,53.840,
5105.20947,570.598,6183.78125,53.840,
5105.30127,569.598,6183.87305,53.840,
5105.39258,569.598,6183.96436,52.840,
5105.48438,570.598,6184.05615,53.840,
5105.57568,570.598,6184.14746,53.840,
5105.66699,569.598,6184.23926,53.840,
5105.75879,569.598,6184.33057,52.840,
5105.85010,569.598,6184.42188,53.840,
5105.94189,569.598,6184.51367,52.840,
5106.03320,569.598,6184.60498,52.840,
5106.12500,569.598,6184.69678,52.840,
5106.21631,569.598,6184.78809,53.840,
5106.30762,568.598,6184.87988,52.840,
5106.39941,568.598,6184.97119,52.840,
5106.49072,568.598,6185.06250,52.840,
5106.58252,568.598,6185.15430,52.840,
5106.67383,568.598,6185.24561,52.840,
5106.76563,567.598,6185.33740,51.840,
5106.85693,567.598,6185.42871,53.840,
5106.94824,567.598,6185.52051,52.840,
5107.04004,568.598,6185.61182,52.840,
5107.13135,567.598,6185.70361,52.840,
5107.22314,567.598,6185.79492,52.840,
5107.31445,567.598,6185.88623,52.840,
5107.40625,568.598,6185.97803,52.840,
5107.49756,568.598,6186.06934,53.840,
5107.58936,569.598,6186.16113,52.840,
5107.68066,569.598,6186.25244,53.840,
5107.77197,570.598,6186.34424,53.840,
5107.86377,570.598,6186.43555,53.840,
5107.95508,570.598,6186.52686,52.840,
5108.04688,570.598,6186.61865,53.840,
5108.13818,570.598,6186.70996,52.840,
5108.22998,570.598,6186.80176,52.840,
5108.32129,570.598,6186.89307,52.840,
5108.41260,569.598,6186.98486,52.840,
5108.50439,569.598,6187.07617,52.840,
5108.59570,569.598,6187.16748,51.840,
5108.68750,568.598,6187.25928,51.840,
5108.77881,568.598,6187.35059,50.840,
5108.87061,568.598,6187.44238,49.840,
5108.96191,567.598,6187.53369,48.840,
5109.05322,567.598,6187.62549,48.840,
5109.14502,567.598,6187.71680,48.840,
5109.23633,566.598,6187.80859,47.840,
5109.32813,566.598,6187.89990,48.840,
5109.41943,566.598,6187.99121,48.840,
5109.51123,565.598,6188.08301,48.840,
5109.60254,565.598,6188.17432,49.840,
5109.69434,565.598,6188.26611,49.840,
5109.78564,564.598,6188.35742,49.840,
5109.87695,564.598,6188.44922,50.840,
5109.96875,564.598,6188.54053,50.840,
5110.06006,563.598,6188.63184,50.840,
5110.15186,563.598,6188.72363,50.840,
5110.24316,563.598,6188.81494,51.840,
5110.33496,563.598,6188.90674,51.840,
5110.42627,562.598,6188.99805,51.840,
5110.51758,562.598,6189.08984,51.840,
5110.60938,562.598,6189.18115,51.840,
5110.70068,562.598,6189.27246,51.840,
5110.79248,562.598,6189.36426,52.840,
5110.88379,562.598,6189.45557,52.840,
5110.97559,562.598,6189.54736,52.840,
5111.06689,562.598,6189.63867,52.840,
5111.15820,562.598,6189.73047,52.840,
5111.25000,562.598,6189.82178,52.840,
5111.34131,562.598,6189.91357,52.840,
5111.43311,563.598,6190.00488,52.840,
5111.52441,562.598,6190.09619,51.840,
5111.61621,562.598,6190.18799,51.840,
5111.70752,562.598,6190.27930,51.840,
5111.79932,562.598,6190.37109,51.840,
5111.89063,562.598,6190.46240,51.840,
5111.98193,562.598,6190.55420,51.840,
5112.07373,562.598,6190.64551,52.840,
5112.16504,562.598,6190.73682,51.840,
5112.25684,562.598,6190.82861,51.840,
5112.34814,562.598,6190.91992,51.840,
5112.43994,562.598,6191.01172,51.840,
5112.53125,561.598,6191.10303,51.840,
5112.62256,561.598,6191.19482,51.840,
5112.71436,562.598,6191.28613,51.840,
5112.80566,561.598,6191.37744,51.840,
5112.89746,562.598,6191.46924,51.840,
5112.98877,562.598,6191.56055,51.840,
5113.08057,562.598,6191.65234,51.840,
5113.17188,561.598,6191.74365,50.840,
5113.26318,561.598,6191.83545,51.840,
5113.35498,561.598,6191.92676,51.840,
5113.44629,561.598,6192.01807,50.840,
5113.53809,561.598,6192.10986,51.840,
5113.62939,561.598,6192.20117,51.840,
5113.72119,561.598,6192.29297,51.840,
5113.81250,561.598,6192.38428,50.840,
5113.90430,560.598,6192.47607,50.840,
5113.99561,560.598,6192.56738,51.840,
5114.08691,560.598,6192.65918,50.840,
5114.17871,560.598,6192.75049,51.840,
5114.27002,560.598,6192.84180,51.840,
5114.36182,560.598,6192.93359,50.840,
5114.45313,560.598,6193.02490,50.840,
5114.54492,560.598,6193.11670,51.840,
5114.63623,560.598,6193.20801,50.840,
5114.72754,560.598,6193.29980,50.840,
5114.81934,560.598,6193.39111,50.840,
5114.91064,559.598,6193.48242,50.840,
5115.00244,560.598,6193.57422,51.840,
5115.09375,559.598,6193.66553,51.840,
5115.18555,559.598,6193.75732,51.840,
5115.27686,558.598,6193.84863,50.840,
5115.36816,559.598,6193.94043,50.840,
5115.45996,559.598,6194.03174,50.840,
5115.55127,559.598,6194.12305,50.840,
5115.64307,558.598,6194.21484,50.840,
5115.73438,558.598,6194.30615,50.840,
5115.82617,559.598,6194.39795,50.840,
5115.91748,558.598,6194.48926,49.840,
5116.00928,559.598,6194.58105,50.840,
5116.10059,558.598,6194.67236,50.840,
5116.19189,558.598,6194.76416,50.840,
5116.28369,558.598,6194.85547,50.840,
5116.37500,558.598,6194.94678,50.840,
5116.46680,558.598,6195.03857,50.840,
5116.55811,558.598,6195.12988,50.840,
5116.64990,558.598,6195.22168,50.840,
5116.74121,558.598,6195.31299,50.840,
5116.83252,557.598,6195.40479,50.840,
5116.92432,557.598,6195.49609,50.840,
5117.01563,557.598,6195.58740,50.840,
5117.10742,557.598,6195.67920,50.840,
5117.19873,557.598,6195.77051,50.840,
5117.29053,558.598,6195.86230,50.840,
5117.38184,557.598,6195.95361,49.840,
5117.47314,557.598,6196.04541,50.840,
5117.56494,557.598,6196.13672,50.840,
5117.65625,556.598,6196.22803,50.840,
5117.74805,556.598,6196.31982,49.840,
5117.83936,556.598,6196.41113,49.840,
5117.93115,556.598,6196.50293,51.840,
5118.02246,556.598,6196.59424,50.840,
5118.11426,556.598,6196.68604,50.840,
5118.20557,556.598,6196.77734,50.840,
5118.29688,555.598,6196.86914,50.840,
5118.38867,555.598,6196.96045,49.840,
5118.47998,555.598,6197.05176,49.840,
5118.57178,555.598,6197.14355,50.840,
5118.66309,555.598,6197.23486,49.840,
5118.75488,556.598,6197.32666,49.840,
5118.84619,555.598,6197.41797,49.840,
5118.93750,555.598,6197.50977,49.840,
5119.02930,555.598,6197.60107,49.840,
5119.12061,555.598,6197.69238,50.840,
5119.21240,554.598,6197.78418,49.840,
5119.30371,554.598,6197.87549,49.840,
5119.39551,555.598,6197.96729,50.840,
5119.48682,554.598,6198.05859,49.840,
5119.57813,554.598,6198.15039,49.840,
5119.66992,554.598,6198.24170,49.840,
5119.76123,554.598,6198.33301,49.840,
5119.85303,554.598,6198.42480,49.840,
5119.94434,553.598,6198.51611,49.840,
5120.03613,554.598,6198.60791,49.840,
5120.12744,554.598,6198.69922,49.840,
5120.21875,554.598,6198.79102,49.840,
5120.31055,554.598,6198.88232,49.840,
5120.40186,553.598,6198.97412,49.840,
5120.49365,553.598,6199.06543,49.840,
5120.58496,554.598,6199.15674,49.840,
5120.67676,553.598,6199.24854,49.840,
5120.76807,553.598,6199.33984,49.840,
5120.85986,553.598,6199.43164,49.840,
5120.95117,553.598,6199.52295,49.840,
5121.04248,552.598,6199.61475,49.840,
5121.13428,553.598,6199.70605,49.840,
5121.22559,552.598,6199.79736,49.840,
5121.31738,552.598,6199.88916,49.840,
5121.40869,552.598,6199.98047,49.840,
5121.50049,552.598,6200.07227,49.840,
5121.59180,552.598,6200.16357,49.840,
5121.68311,552.598,6200.25537,48.840,
5121.77490,552.598,6200.34668,49.840,
5121.86621,552.598,6200.43799,48.840,
5121.95801,552.598,6200.52979,49.840,
5122.04932,552.598,6200.62109,49.840,
5122.14111,551.598,6200.71289,49.840,
5122.23242,552.598,6200.80420,49.840,
5122.32373,551.598,6200.89600,49.840,
5122.41553,551.598,6200.98730,49.840,
5122.50684,551.598,6201.07910,49.840,
5122.59863,551.598,6201.17041,48.840,
5122.68994,551.598,6201.26172,48.840,
5122.78174,551.598,6201.35352,49.840,
5122.87305,551.598,6201.44482,48.840,
5122.96484,550.598,6201.53662,49.840,
5123.05615,551.598,6201.62793,48.840,
5123.14746,551.598,6201.71973,49.840,
5123.23926,551.598,6201.81104,48.840,
5123.33057,551.598,6201.90234,49.840,
5123.42236,550.598,6201.99414,48.840,
5123.51367,550.598,6202.08545,48.840,
5123.60547,550.598,6202.17725,48.840,
5123.69678,550.598,6202.26855,48.840,
5123.78809,550.598,6202.36035,49.840,
5123.87988,550.598,6202.45166,49.840,
5123.97119,550.598,6202.54297,49.840,
5124.06299,550.598,6202.63477,49.840,
5124.15430,549.598,6202.72607,49.840,
5124.24609,549.598,6202.81787,49.840,
5124.33740,549.598,6202.90918,49.840,
5124.42871,549.598,6203.00098,48.840,
5124.52051,549.598,6203.09229,48.840,
5124.61182,550.598,6203.18408,48.840,
5124.70361,549.598,6203.27539,48.840,
5124.79492,549.598,6203.36670,48.840,
5124.88672,549.598,6203.45850,49.840,
5124.97803,549.598,6203.54980,49.840,
5125.06982,549.598,6203.64160,49.840,
5125.16113,549.598,6203.73291,49.840,
5125.25244,549.598,6203.82471,50.840,
5125.34424,548.598,6203.91602,50.840,
5125.43555,549.598,6204.00732,50.840,
5125.52734,548.598,6204.09912,50.840,
5125.61865,548.598,6204.19043,49.840,
5125.71045,548.598,6204.28223,50.840,
5125.80176,547.598,6204.37354,49.840,
5125.89307,548.598,6204.46533,49.840,
5125.98486,548.598,6204.55664,49.840,
5126.07617,548.598,6204.64795,49.840,
5126.16797,547.598,6204.73975,49.840,
5126.25928,547.598,6204.83105,49.840,
5126.35107,547.598,6204.92285,49.840,
5126.44238,547.598,6205.01416,48.840,
5126.53369,547.598,6205.10596,48.840,
5126.62549,547.598,6205.19727,48.840,
5126.71680,547.598,6205.28857,49.840,
5126.80859,546.598,6205.38037,48.840,
5126.89990,545.598,6205.47168,48.840,
5126.99170,545.598,6205.56348,48.840,
5127.08301,544.598,6205.65479,47.840,
5127.17480,543.598,6205.74658,47.840,
5127.26611,543.598,6205.83789,47.840,
5127.35742,542.598,6205.92969,47.840,
5127.44922,542.598,6206.02100,47.840,
5127.54053,542.598,6206.11230,47.840,
5127.63232,542.598,6206.20410,47.840,
5127.72363,542.598,6206.29541,47.840,
5127.81543,542.598,6206.38721,46.840,
5127.90674,542.598,6206.47852,46.840,
5127.99805,542.598,6206.57031,46.840,
5128.08984,542.598,6206.66162,45.840,
5128.18115,543.598,6206.75293,46.840,
5128.27295,542.598,6206.84473,46.840,
5128.36426,543.598,6206.93604,46.840,
5128.45605,542.598,6207.02783,46.840,
5128.54736,543.598,6207.11914,46.840,
5128.63867,543.598,6207.21094,46.840,
5128.73047,543.598,6207.30225,47.840,
5128.82178,543.598,6207.39355,47.840,
5128.91357,544.598,6207.48535,47.840,
5129.00488,544.598,6207.57666,47.840,
5129.09668,543.598,6207.66846,47.840,
5129.18799,544.598,6207.75977,47.840,
5129.27979,543.598,6207.85156,47.840,
5129.37109,544.598,6207.94287,47.840,
5129.46240,544.598,6208.03467,47.840,
5129.55420,544.598,6208.12598,47.840,
5129.64551,544.598,6208.21729,48.840,
5129.73730,544.598,6208.30908,47.840,
5129.82861,543.598,6208.40039,47.840,
5129.92041,543.598,6208.49219,47.840,
5130.01172,543.598,6208.58350,47.840,
5130.10303,543.598,6208.67529,47.840,
5130.19482,543.598,6208.76660,48.840,
5130.28613,543.598,6208.85791,47.840,
5130.37793,543.598,6208.94971,47.840,
5130.46924,543.598,6209.04102,47.840,
5130.56104,542.598,6209.13281,47.840,
5130.65234,542.598,6209.22412,47.840,
5130.74365,542.598,6209.31592,47.840,
5130.83545,542.598,6209.40723,47.840,
5130.92676,542.598,6209.49854,47.840,
5131.01855,542.598,6209.59033,47.840,
5131.10986,542.598,6209.68164,47.840,
5131.20166,542.598,6209.77344,47.840,
5131.29297,542.598,6209.86475,47.840,
5131.38428,542.598,6209.95654,47.840,
5131.47607,542.598,6210.04785,47.840,
5131.56738,541.598,6210.13965,47.840,
5131.65918,542.598,6210.23096,47.840,
5131.75049,542.598,6210.32227,47.840,
5131.84229,541.598,6210.41406,47.840,
5131.93359,542.598,6210.50537,47.840,
5132.02539,541.598,6210.59717,46.840,
5132.11670,541.598,6210.68848,47.840,
5132.20801,541.598,6210.78027,46.840,
5132.29980,541.598,6210.87158,47.840,
5132.39111,541.598,6210.96289,46.840,
5132.48291,541.598,6211.05469,46.840,
5132.57422,541.598,6211.14600,47.840,
5132.66602,541.598,6211.23779,46.840,
5132.75732,541.598,6211.32910,46.840,
5132.84863,541.598,6211.42090,47.840,
5132.94043,541.598,6211.51221,46.840,
5133.03174,540.598,6211.60352,46.840,
5133.12354,540.598,6211.69531,46.840,
5133.21484,540.598,6211.78662,46.840,
5133.30664,540.598,6211.87842,46.840,
5133.39795,540.598,6211.96973,46.840,
5133.48926,540.598,6212.06152,46.840,
5133.58105,539.598,6212.15283,45.840,
5133.67236,539.598,6212.24463,46.840,
5133.76416,539.598,6212.33594,46.840,
5133.85547,539.598,6212.42725,46.840,
5133.94727,539.598,6212.51904,46.840,
5134.03857,539.598,6212.61035,46.840,
5134.13037,539.598,6212.70215,46.840,
5134.22168,538.598,6212.79346,46.840,
5134.31299,538.598,6212.88525,46.840,
5134.40479,539.598,6212.97656,46.840,
5134.49609,539.598,6213.06787,46.840,
5134.58789,538.598,6213.15967,46.840,
5134.67920,539.598,6213.25098,46.840,
5134.77100,538.598,6213.34277,46.840,
5134.86230,538.598,6213.43408,46.840,
5134.95361,538.598,6213.52588,45.840,
5135.04541,538.598,6213.61719,46.840,
5135.13672,538.598,6213.70850,46.840,
5135.22852,538.598,6213.80029,45.840,
5135.31982,538.598,6213.89160,46.840,
5135.41162,538.598,6213.98340,46.840,
5135.50293,538.598,6214.07471,46.840,
5135.59424,538.598,6214.16650,46.840,
5135.68604,537.598,6214.25781,46.840,
5135.77734,537.598,6214.34961,45.840,
5135.86914,538.598,6214.44092,46.840,
5135.96045,537.598,6214.53223,45.840,
5136.05225,537.598,6214.62402,46.840,
5136.14355,537.598,6214.71533,45.840,
5136.23535,537.598,6214.80713,45.840,
5136.32666,537.598,6214.89844,45.840,
5136.41797,537.598,6214.99023,45.840,
5136.50977,537.598,6215.08154,45.840,
5136.60107,536.598,6215.17285,45.840,
5136.69287,536.598,6215.26465,45.840,
5136.78418,537.598,6215.35596,45.840,
5136.87598,537.598,6215.44775,45.840,
5136.96729,537.598,6215.53906,46.840,
5137.05859,537.598,6215.63086,45.840,
5137.15039,536.598,6215.72217,45.840,
5137.24170,536.598,6215.81348,45.840,
5137.33350,536.598,6215.90527,45.840,
5137.42480,536.598,6215.99658,45.840,
5137.51660,536.598,6216.08838,45.840,
5137.60791,536.598,6216.17969,45.840,
5137.69922,536.598,6216.27148,45.840,
5137.79102,536.598,6216.36279,45.840,
5137.88232,536.598,6216.45410,45.840,
5137.97412,535.598,6216.54590,45.840,
5138.06543,535.598,6216.63721,45.840,
5138.15723,535.598,6216.72900,45.840,
5138.24854,535.598,6216.82031,45.840,
5138.34033,535.598,6216.91211,45.840,
5138.43164,535.598,6217.00342,45.840,
5138.52295,535.598,6217.09521,45.840,
5138.61475,534.598,6217.18652,45.840,
5138.70605,534.598,6217.27783,45.840,
5138.79785,534.598,6217.36963,45.840,
5138.88916,534.598,6217.46094,45.840,
5138.98096,534.598,6217.55273,45.840,
5139.07227,534.598,6217.64404,45.840,
5139.16357,534.598,6217.73584,45.840,
5139.25537,534.598,6217.82715,45.840,
5139.34668,534.598,6217.91846,45.840,
5139.43848,534.598,6218.01025,45.840,
5139.52979,534.598,6218.10156,44.840,
5139.62158,533.598,6218.19336,45.840,
5139.71289,533.598,6218.28467,44.840,
5139.80420,534.598,6218.37646,45.840,
5139.89600,533.598,6218.46777,45.840,
5139.98730,533.598,6218.55908,45.840,
5140.07910,533.598,6218.65088,45.840,
5140.17041,533.598,6218.74219,44.840,
5140.26221,533.598,6218.83398,45.840,
5140.35352,533.598,6218.92529,45.840,
5140.44531,533.598,6219.01709,44.840,
5140.53662,532.598,6219.10840,45.840,
5140.62793,532.598,6219.20020,45.840,
5140.71973,533.598,6219.29150,44.840,
5140.81104,532.598,6219.38281,44.840,
5140.90283,532.598,6219.47461,44.840,
5140.99414,532.598,6219.56592,44.840,
5141.08594,533.598,6219.65771,44.840,
5141.17725,532.598,6219.74902,44.840,
5141.26855,532.598,6219.84082,44.840,
5141.36035,532.598,6219.93213,45.840,
5141.45166,532.598,6220.02344,44.840,
5141.54346,532.598,6220.11523,44.840,
5141.63477,532.598,6220.20654,44.840,
5141.72656,532.598,6220.29834,44.840,
5141.81787,532.598,6220.38965,44.840,
5141.90918,532.598,6220.48145,44.840,
5142.00098,532.598,6220.57275,44.840,
5142.09229,532.598,6220.66406,44.840,
5142.18408,532.598,6220.75586,44.840,
5142.27539,532.598,6220.84717,44.840,
5142.36719,531.598,6220.93896,44.840,
5142.45850,531.598,6221.03027,44.840,
5142.55029,531.598,6221.12207,44.840,
5142.64160,531.598,6221.21338,44.840,
5142.73291,530.598,6221.30518,44.840,
5142.82471,531.598,6221.39648,45.840,
5142.91602,530.598,6221.48779,44.840,
5143.00781,530.598,6221.57959,44.840,
5143.09912,530.598,6221.67090,44.840,
5143.19092,530.598,6221.76270,44.840,
5143.28223,530.598,6221.85400,44.840,
5143.37354,529.598,6221.94580,44.840,
5143.46533,530.598,6222.03711,44.840,
5143.55664,530.598,6222.12842,44.840,
5143.64844,530.598,6222.22021,45.840,
5143.73975,530.598,6222.31152,45.840,
5143.83154,530.598,6222.40332,46.840,
5143.92285,530.598,6222.49463,47.840,
5144.01416,529.598,6222.58643,46.840,
5144.10596,530.598,6222.67773,46.840,
5144.19727,530.598,6222.76904,46.840,
5144.28906,530.598,6222.86084,48.840,
5144.38037,530.598,6222.95215,47.840,
5144.47217,530.598,6223.04395,46.840,
5144.56348,530.598,6223.13525,46.840,
5144.65479,530.598,6223.22705,46.840,
5144.74658,530.598,6223.31836,46.840,
5144.83789,530.598,6223.41016,45.840,
5144.92969,529.598,6223.50146,45.840,
5145.02100,529.598,6223.59277,45.840,
5145.11279,529.598,6223.68457,45.840,
5145.20410,529.598,6223.77588,45.840,
5145.29590,528.598,6223.86768,44.840,
5145.38721,528.598,6223.95898,44.840,
5145.47852,528.598,6224.05078,44.840,
5145.57031,528.598,6224.14209,44.840,
5145.66162,528.598,6224.23340,43.840,
5145.75342,527.598,6224.32520,44.840,
5145.84473,528.598,6224.41650,44.840,
5145.93652,527.598,6224.50830,44.840,
5146.02783,527.598,6224.59961,44.840,
5146.11914,526.598,6224.69141,44.840,
5146.21094,527.598,6224.78271,45.840,
5146.30225,527.598,6224.87402,44.840,
5146.39404,526.598,6224.96582,45.840,
5146.48535,526.598,6225.05713,45.840,
5146.57715,526.598,6225.14893,44.840,
5146.66846,526.598,6225.24023,45.840,
5146.75977,526.598,6225.33203,44.840,
5146.85156,526.598,6225.42334,44.840,
5146.94287,526.598,6225.51514,44.840,
5147.03467,525.598,6225.60645,44.840,
5147.12598,525.598,6225.69775,44.840,
5147.21777,526.598,6225.78955,44.840,
5147.30908,525.598,6225.88086,43.840,
5147.40088,525.598,6225.97266,44.840,
5147.49219,525.598,6226.06396,44.840,
5147.58350,525.598,6226.15576,43.840,
5147.67529,524.598,6226.24707,43.840,
5147.76660,525.598,6226.33838,43.840,
5147.85840,524.598,6226.43018,43.840,
5147.94971,524.598,6226.52148,43.840,
5148.04150,525.598,6226.61328,43.840,
5148.13281,524.598,6226.70459,42.840,
5148.22412,524.598,6226.79639,43.840,
5148.31592,524.598,6226.88770,43.840,
5148.40723,524.598,6226.97900,42.840,
5148.49902,524.598,6227.07080,42.840,
5148.59033,524.598,6227.16211,43.840,
5148.68213,524.598,6227.25391,43.840,
5148.77344,524.598,6227.34521,43.840,
5148.86475,523.598,6227.43701,42.840,
5148.95654,523.598,6227.52832,42.840,
5149.04785,523.598,6227.62012,42.840,
5149.13965,523.598,6227.71143,42.840,
5149.23096,523.598,6227.80273,43.840,
5149.32275,523.598,6227.89453,42.840,
5149.41406,523.598,6227.98584,43.840,
5149.50586,523.598,6228.07764,42.840,
5149.59717,523.598,6228.16895,42.840,
5149.68848,523.598,6228.26074,42.840,
5149.78027,522.598,6228.35205,42.840,
5149.87158,523.598,6228.44336,42.840,
5149.96338,522.598,6228.53516,42.840,
5150.05469,522.598,6228.62646,42.840,
5150.14648,522.598,6228.71826,43.840,
5150.23779,522.598,6228.80957,42.840,
5150.32910,521.598,6228.90137,42.840,
5150.42090,522.598,6228.99268,42.840,
5150.51221,522.598,6229.08398,42.840,
5150.60400,521.598,6229.17578,42.840,
5150.69531,521.598,6229.26709,42.840,
5150.78711,521.598,6229.35889,42.840,
5150.87842,521.598,6229.45020,41.840,
5150.96973,522.598,6229.54199,42.840,
5151.06152,521.598,6229.63330,42.840,
5151.15283,521.598,6229.72461,41.840,
5151.24463,521.598,6229.81641,42.840,
5151.33594,521.598,6229.90771,42.840,
5151.42773,521.598,6229.99951,41.840,
5151.51904,521.598,6230.09082,42.840,
5151.61084,520.598,6230.18262,43.840,
5151.70215,521.598,6230.27393,42.840,
5151.79346,520.598,6230.36572,41.840,
5151.88525,520.598,6230.45703,42.840,
5151.97656,520.598,6230.54834,42.840,
5152.06836,520.598,6230.64014,41.840,
5152.15967,520.598,6230.73145,41.840,
5152.25146,520.598,6230.82324,42.840,
5152.34277,520.598,6230.91455,42.840,
5152.43408,520.598,6231.00635,42.840,
5152.52588,520.598,6231.09766,42.840,
5152.61719,520.598,6231.18896,42.840,
5152.70898,519.598,6231.28076,42.840,
5152.80029,519.598,6231.37207,41.840,
5152.89209,519.598,6231.46387,42.840,
5152.98340,519.598,6231.55518,41.840,
5153.07471,519.598,6231.64697,42.840,
5153.16650,519.598,6231.73828,41.840,
5153.25781,519.598,6231.82959,41.840,
5153.34961,518.598,6231.92139,41.840,
5153.44092,518.598,6232.01270,41.840,
5153.53271,519.598,6232.10449,41.840,
5153.62402,518.598,6232.19580,41.840,
5153.71582,518.598,6232.28760,42.840,
5153.80713,518.598,6232.37891,41.840,
5153.89844,518.598,6232.47070,41.840,
5153.99023,518.598,6232.56201,41.840,
5154.08154,518.598,6232.65332,41.840,
5154.17334,518.598,6232.74512,41.840,
5154.26465,517.598,6232.83643,41.840,
5154.35645,517.598,6232.92822,41.840,
5154.44775,517.598,6233.01953,41.840,
5154.53906,518.598,6233.11133,42.840,
5154.63086,517.598,6233.20264,41.840,
5154.72217,517.598,6233.29395,41.840,
5154.81396,517.598,6233.38574,41.840,
5154.90527,517.598,6233.47705,41.840,
5154.99707,517.598,6233.56885,41.840,
5155.08838,517.598,6233.66016,41.840,
5155.17969,516.598,6233.75195,41.840,
5155.27148,517.598,6233.84326,41.840,
5155.36279,517.598,6233.93457,41.840,
5155.45459,517.598,6234.02637,41.840,
5155.54590,516.598,6234.11768,41.840,
5155.63770,516.598,6234.20947,41.840,
5155.72900,516.598,6234.30078,41.840,
5155.82080,516.598,6234.39258,41.840,
5155.91211,516.598,6234.48389,41.840,
5156.00342,516.598,6234.57568,41.840,
5156.09521,516.598,6234.66699,41.840,
5156.18652,516.598,6234.75830,41.840,
5156.27832,515.598,6234.85010,40.840,
5156.36963,515.598,6234.94141,40.840,
5156.46143,515.598,6235.03320,41.840,
5156.55273,515.598,6235.12451,40.840,
5156.64404,515.598,6235.21631,40.840,
5156.73584,515.598,6235.30762,40.840,
5156.82715,515.598,6235.39893,41.840,
5156.91895,515.598,6235.49072,41.840,
5157.01025,515.598,6235.58203,41.840,
5157.10205,515.598,6235.67383,40.840,
5157.19336,515.598,6235.76514,40.840,
5157.28467,515.598,6235.85693,40.840,
5157.37646,514.598,6235.94824,41.840,
5157.46777,514.598,6236.03955,41.840,
5157.55957,514.598,6236.13135,41.840,
5157.65088,514.598,6236.22266,41.840,
5157.74268,514.598,6236.31445,41.840,
5157.83398,514.598,6236.40576,41.840,
5157.92529,514.598,6236.49756,41.840,
5158.01709,514.598,6236.58887,40.840,
5158.10840,514.598,6236.68066,40.840,
5158.20020,515.598,6236.77197,40.840,
5158.29150,515.598,6236.86328,40.840,
5158.38330,516.598,6236.95508,40.840,
5158.47461,515.598,6237.04639,40.840,
5158.56641,516.598,6237.13818,40.840,
5158.65771,516.598,6237.22949,40.840,
5158.74902,516.598,6237.32129,41.840,
5158.84082,516.598,6237.41260,40.840,
5158.93213,515.598,6237.50391,41.840,
5159.02393,515.598,6237.59570,40.840,
5159.11523,515.598,6237.68701,40.840,
5159.20703,514.598,6237.77881,40.840,
5159.29834,514.598,6237.87012,40.840,
5159.38965,514.598,6237.96191,40.840,
5159.48145,513.598,6238.05322,41.840,
5159.57275,513.598,6238.14453,40.840,
5159.66455,513.598,6238.23633,40.840,
5159.75586,513.598,6238.32764,40.840,
5159.84766,512.598,6238.41943,40.840,
5159.93896,513.598,6238.51074,40.840,
5160.03027,512.598,6238.60254,39.840,
5160.12207,512.598,6238.69385,39.840,
5160.21338,512.598,6238.78564,40.840,
5160.30518,512.598,6238.87695,39.840,
5160.39648,511.598,6238.96826,40.840,
5160.48828,511.598,6239.06006,40.840,
5160.57959,511.598,6239.15137,40.840,
5160.67139,511.598,6239.24316,40.840,
5160.76270,511.598,6239.33447,40.840,
5160.85400,512.598,6239.42627,40.840,
5160.94580,512.598,6239.51758,39.840,
5161.03711,512.598,6239.60889,39.840,
5161.12891,512.598,6239.70068,39.840,
5161.22021,513.598,6239.79199,39.840,
5161.31201,512.598,6239.88379,39.840,
5161.40332,512.598,6239.97510,39.840,
5161.49463,512.598,6240.06689,39.840,
5161.58643,511.598,6240.15820,39.840,
5161.67773,511.598,6240.24951,39.840,
5161.76953,511.598,6240.34131,39.840,
5161.86084,511.598,6240.43262,40.840,
5161.95264,510.598,6240.52441,39.840,
5162.04395,510.598,6240.61572,39.840,
5162.13525,510.598,6240.70752,39.840,
5162.22705,509.598,6240.79883,39.840,
5162.31836,510.598,6240.89063,39.840,
5162.41016,509.598,6240.98193,39.840,
5162.50146,509.598,6241.07324,38.840,
5162.59326,509.598,6241.16504,38.840,
5162.68457,510.598,6241.25635,37.840,
5162.77637,509.598,6241.34814,37.840,
5162.86768,508.598,6241.43945,37.840,
5162.95898,508.598,6241.53125,37.840,
5163.05078,508.598,6241.62256,37.840,
5163.14209,508.598,6241.71387,37.840,
5163.23389,508.598,6241.80566,38.840,
5163.32520,508.598,6241.89697,39.840,
5163.41699,508.598,6241.98877,38.840,
5163.50830,508.598,6242.08008,39.840,
5163.59961,508.598,6242.17188,39.840,
5163.69141,507.598,6242.26318,39.840,
5163.78271,507.598,6242.35449,39.840,
5163.87451,507.598,6242.44629,39.840,
5163.96582,507.598,6242.53760,39.840,
5164.05762,506.598,6242.62939,39.840,
5164.14893,507.598,6242.72070,39.840,
5164.24023,507.598,6242.81250,39.840,
5164.33203,506.598,6242.90381,38.840,
5164.42334,507.598,6242.99512,39.840,
5164.51514,507.598,6243.08691,39.840,
5164.60645,507.598,6243.17822,39.840,
5164.69824,507.598,6243.27002,37.840,
5164.78955,506.598,6243.36133,38.840,
5164.88135,506.598,6243.45313,36.840,
5164.97266,506.598,6243.54443,36.840,
5165.06396,506.598,6243.63623,35.840,
5165.15576,506.598,6243.72754,34.840,
5165.24707,505.598,6243.81885,34.840,
5165.33887,506.598,6243.91064,34.840,
5165.43018,505.598,6244.00195,34.840,
5165.52197,506.598,6244.09375,34.840,
5165.61328,506.598,6244.18506,34.840,
5165.70459,505.598,6244.27686,35.840,
5165.79639,505.598,6244.36816,35.840,
5165.88770,505.598,6244.45947,36.840,
5165.97949,505.598,6244.55127,36.840,
5166.07080,505.598,6244.64258,36.840,
5166.16260,505.598,6244.73438,37.840,
5166.25391,505.598,6244.82568,37.840,
5166.34521,505.598,6244.91748,37.840,
5166.43701,505.598,6245.00879,37.840,
5166.52832,505.598,6245.10010,37.840,
5166.62012,504.598,6245.19189,37.840,
5166.71143,504.598,6245.28320,38.840,
5166.80322,504.598,6245.37500,38.840,
5166.89453,504.598,6245.46631,38.840,
5166.98633,505.598,6245.55811,39.840,
5167.07764,504.598,6245.64941,38.840,
5167.16895,504.598,6245.74121,38.840,
5167.26074,504.598,6245.83252,38.840,
5167.35205,503.598,6245.92383,38.840,
5167.44385,503.598,6246.01563,37.840,
5167.53516,503.598,6246.10693,38.840,
5167.62695,504.598,6246.19873,38.840,
5167.71826,503.598,6246.29004,38.840,
5167.80957,503.598,6246.38184,38.840,
5167.90137,503.598,6246.47314,38.840,
5167.99268,503.598,6246.56445,38.840,
5168.08447,502.598,6246.65625,37.840,
5168.17578,503.598,6246.74756,37.840,
5168.26758,503.598,6246.83936,38.840,
5168.35889,502.598,6246.93066,37.840,
5168.45020,503.598,6247.02246,37.840,
5168.54199,503.598,6247.11377,37.840,
5168.63330,502.598,6247.20508,38.840,
5168.72510,502.598,6247.29688,37.840,
5168.81641,502.598,6247.38818,38.840,
5168.90820,502.598,6247.47998,37.840,
5168.99951,502.598,6247.57129,37.840,
5169.09082,502.598,6247.66309,37.840,
5169.18262,501.598,6247.75439,38.840,
5169.27393,502.598,6247.84619,37.840,
5169.36572,502.598,6247.93750,37.840,
5169.45703,501.598,6248.02881,38.840,
5169.54883,501.598,6248.12061,37.840,
5169.64014,501.598,6248.21191,37.840,
5169.73193,501.598,6248.30371,37.840,
5169.82324,501.598,6248.39502,37.840,
5169.91455,501.598,6248.48682,37.840,
5170.00635,502.598,6248.57813,37.840,
5170.09766,501.598,6248.66943,38.840,
5170.18945,501.598,6248.76123,37.840,
5170.28076,501.598,6248.85254,37.840,
5170.37256,501.598,6248.94434,37.840,
5170.46387,500.598,6249.03564,37.840,
5170.55518,501.598,6249.12744,37.840,
5170.64697,500.598,6249.21875,38.840,
5170.73828,500.598,6249.31006,37.840,
5170.83008,500.598,6249.40186,37.840,
5170.92139,500.598,6249.49316,37.840,
5171.01318,500.598,6249.58496,37.840,
5171.10449,499.598,6249.67627,37.840,
5171.19580,500.598,6249.76807,37.840,
5171.28760,500.598,6249.85938,37.840,
5171.37891,499.598,6249.95117,37.840,
5171.47070,500.598,6250.04248,36.840,
5171.56201,499.598,6250.13379,37.840,
5171.65381,500.598,6250.22559,37.840,
5171.74512,499.598,6250.31689,36.840,
5171.83691,499.598,6250.40869,37.840,
5171.92822,499.598,6250.50000,37.840,
5172.01953,499.598,6250.59180,37.840,
5172.11133,499.598,6250.68311,37.840,
5172.20264,499.598,6250.77441,37.840,
5172.29443,499.598,6250.86621,37.840,
5172.38574,498.598,6250.95752,37.840,
5172.47754,498.598,6251.04932,37.840,
5172.56885,498.598,6251.14063,37.840,
5172.66016,498.598,6251.23242,36.840,
5172.75195,498.598,6251.32373,37.840,
5172.84326,498.598,6251.41504,37.840,
5172.93506,498.598,6251.50684,36.840,
5173.02637,498.598,6251.59814,36.840,
5173.11816,498.598,6251.68994,36.840,
5173.20947,498.598,6251.78125,37.840,
5173.30078,498.598,6251.87305,36.840,
5173.39258,498.598,6251.96436,37.840,
5173.48389,497.598,6252.05615,37.840,
5173.57568,497.598,6252.14746,36.840,
5173.66699,498.598,6252.23877,36.840,
5173.75879,496.598,6252.33057,37.840,
5173.85010,496.598,6252.42188,36.840,
5173.94189,497.598,6252.51367,36.840,
5174.03320,496.598,6252.60498,36.840,
5174.12451,496.598,6252.69678,36.840,
5174.21631,496.598,6252.78809,36.840,
5174.30762,496.598,6252.87939,36.840,
5174.39941,497.598,6252.97119,36.840,
5174.49072,497.598,6253.06250,36.840,
5174.58252,496.598,6253.15430,36.840,
5174.67383,496.598,6253.24561,37.840,
5174.76514,496.598,6253.33740,36.840,
5174.85693,496.598,6253.42871,36.840,
5174.94824,496.598,6253.52002,36.840,
5175.04004,496.598,6253.61182,37.840,
5175.13135,496.598,6253.70313,36.840,
5175.22314,496.598,6253.79492,36.840,
5175.31445,496.598,6253.88623,36.840,
5175.40576,497.598,6253.97803,36.840,
5175.49756,497.598,6254.06934,36.840,
5175.58887,496.598,6254.16064,36.840,
5175.68066,497.598,6254.25244,36.840,
5175.77197,496.598,6254.34375,36.840,
5175.86377,497.598,6254.43555,36.840,
5175.95508,496.598,6254.52686,35.840,
5176.04688,496.598,6254.61865,35.840,
5176.13818,496.598,6254.70996,36.840,
5176.22949,495.598,6254.80176,36.840,
5176.32129,495.598,6254.89307,36.840,
5176.41260,495.598,6254.98438,36.840,
5176.50439,495.598,6255.07617,37.840,
5176.59570,495.598,6255.16748,36.840,
5176.68750,494.598,6255.25928,36.840,
5176.77881,494.598,6255.35059,36.840,
5176.87012,494.598,6255.44238,36.840,
5176.96191,494.598,6255.53369,36.840,
5177.05322,494.598,6255.62500,36.840,
5177.14502,493.598,6255.71680,36.840,
5177.23633,493.598,6255.80811,36.840,
5177.32813,494.598,6255.89990,36.840,
5177.41943,494.598,6255.99121,36.840,
5177.51074,493.598,6256.08301,36.840,
5177.60254,494.598,6256.17432,36.840,
5177.69385,494.598,6256.26563,36.840,
5177.78564,494.598,6256.35742,36.840,
5177.87695,496.598,6256.44873,36.840,
5177.96875,496.598,6256.54053,37.840,
5178.06006,496.598,6256.63184,36.840,
5178.15186,496.598,6256.72363,36.840,
5178.24316,496.598,6256.81494,36.840,
5178.33447,496.598,6256.90674,36.840,
5178.42627,496.598,6256.99805,35.840,
5178.51758,496.598,6257.08936,36.840,
5178.60938,495.598,6257.18115,36.840,
5178.70068,495.598,6257.27246,36.840,
5178.79248,495.598,6257.36426,35.840,
5178.88379,494.598,6257.45557,35.840,
5178.97510,493.598,6257.54736,36.840,
5179.06689,493.598,6257.63867,35.840,
5179.15820,493.598,6257.72998,36.840,
5179.25000,493.598,6257.82178,36.840,
5179.34131,492.598,6257.91309,36.840,
5179.43311,492.598,6258.00488,36.840,
5179.52441,491.598,6258.09619,36.840,
5179.61572,491.598,6258.18799,36.840,
5179.70752,491.598,6258.27930,35.840,
5179.79883,491.598,6258.37061,36.840,
5179.89063,490.598,6258.46240,36.840,
5179.98193,490.598,6258.55371,35.840,
5180.07373,490.598,6258.64551,36.840,
5180.16504,490.598,6258.73682,35.840,
5180.25684,491.598,6258.82861,36.840,
5180.34814,490.598,6258.91992,35.840,
5180.43945,490.598,6259.01172,35.840,
5180.53125,490.598,6259.10303,35.840,
5180.62256,490.598,6259.19434,35.840,
5180.71436,489.598,6259.28613,35.840,
5180.80566,490.598,6259.37744,36.840,
5180.89746,489.598,6259.46924,36.840,
5180.98877,489.598,6259.56055,36.840,
5181.08008,489.598,6259.65234,36.840,
5181.17188,489.598,6259.74365,37.840,
5181.26318,489.598,6259.83496,37.840,
5181.35498,489.598,6259.92676,37.840,
5181.44629,488.598,6260.01807,37.840,
5181.53809,489.598,6260.10986,37.840,
5181.62939,488.598,6260.20117,38.840,
5181.72070,489.598,6260.29297,37.840,
5181.81250,488.598,6260.38428,37.840,
5181.90381,488.598,6260.47559,38.840,
5181.99561,488.598,6260.56738,37.840,
5182.08691,488.598,6260.65869,37.840,
5182.17871,488.598,6260.75049,37.840,
5182.27002,488.598,6260.84180,37.840,
5182.36133,488.598,6260.93359,38.840,
5182.45313,488.598,6261.02490,36.840,
5182.54443,487.598,6261.11670,36.840,
5182.63623,487.598,6261.20801,36.840,
5182.72754,487.598,6261.29932,36.840,
5182.81934,487.598,6261.39111,36.840,
5182.91064,487.598,6261.48242,35.840,
5183.00244,487.598,6261.57422,36.840,
5183.09375,487.598,6261.66553,35.840,
5183.18506,487.598,6261.75732,35.840,
5183.27686,487.598,6261.84863,35.840,
5183.36816,487.598,6261.93994,35.840,
5183.45996,487.598,6262.03174,36.840,
5183.55127,486.598,6262.12305,36.840,
5183.64307,487.598,6262.21484,36.840,
5183.73438,487.598,6262.30615,35.840,
5183.82568,486.598,6262.39795,36.840,
5183.91748,486.598,6262.48926,36.840,
5184.00879,486.598,6262.58057,35.840,
5184.10059,486.598,6262.67236,35.840,
5184.19189,486.598,6262.76367,35.840,
5184.28369,486.598,6262.85547,35.840,
5184.37500,486.598,6262.94678,36.840,
5184.46631,485.598,6263.03857,36.840,
5184.55811,485.598,6263.12988,35.840,
5184.64941,486.598,6263.22168,35.840,
5184.74121,485.598,6263.31299,35.840,
5184.83252,485.598,6263.40430,35.840,
5184.92432,485.598,6263.49609,35.840,
5185.01563,485.598,6263.58740,35.840,
5185.10742,485.598,6263.67920,35.840,
5185.19873,485.598,6263.77051,35.840,
5185.29004,485.598,6263.86230,36.840,
5185.38184,485.598,6263.95361,36.840,
5185.47314,484.598,6264.04492,35.840,
5185.56494,485.598,6264.13672,35.840,
5185.65625,484.598,6264.22803,35.840,
5185.74805,484.598,6264.31982,35.840,
5185.83936,484.598,6264.41113,35.840,
5185.93066,484.598,6264.50293,35.840,
5186.02246,484.598,6264.59424,35.840,
5186.11377,484.598,6264.68555,35.840,
5186.20557,484.598,6264.77734,35.840,
5186.29688,484.598,6264.86865,35.840,
5186.38867,484.598,6264.96045,35.840,
5186.47998,483.598,6265.05176,34.840,
5186.57129,484.598,6265.14355,34.840,
5186.66309,483.598,6265.23486,35.840,
5186.75439,483.598,6265.32666,35.840,
5186.84619,483.598,6265.41797,34.840,
5186.93750,483.598,6265.50928,34.840,
5187.02930,483.598,6265.60107,35.840,
5187.12061,483.598,6265.69238,34.840,
5187.21240,482.598,6265.78418,34.840,
5187.30371,483.598,6265.87549,34.840,
5187.39502,482.598,6265.96729,34.840,
5187.48682,483.598,6266.05859,34.840,
5187.57813,483.598,6266.14990,34.840,
5187.66992,483.598,6266.24170,34.840,
5187.76123,482.598,6266.33301,34.840,
5187.85303,482.598,6266.42480,34.840,
5187.94434,482.598,6266.51611,34.840,
5188.03564,482.598,6266.60791,34.840,
5188.12744,482.598,6266.69922,34.840,
5188.21875,482.598,6266.79053,35.840,
5188.31055,482.598,6266.88232,34.840,
5188.40186,481.598,6266.97363,34.840,
5188.49365,481.598,6267.06543,34.840,
5188.58496,482.598,6267.15674,34.840,
5188.67627,481.598,6267.24854,34.840,
5188.76807,481.598,6267.33984,34.840,
5188.85938,481.598,6267.43115,34.840,
5188.95117,481.598,6267.52295,34.840,
5189.04248,481.598,6267.61426,34.840,
5189.13428,481.598,6267.70605,34.840,
5189.22559,481.598,6267.79736,34.840,
5189.31738,480.598,6267.88916,34.840,
5189.40869,480.598,6267.98047,35.840,
5189.50000,481.598,6268.07227,34.840,
5189.59180,480.598,6268.16357,34.840,
5189.68311,480.598,6268.25488,34.840,
5189.77490,480.598,6268.34668,34.840,
5189.86621,480.598,6268.43799,34.840,
5189.95801,480.598,6268.52979,34.840,
5190.04932,480.598,6268.62109,34.840,
5190.14063,480.598,6268.71289,34.840,
5190.23242,479.598,6268.80420,34.840,
5190.32373,479.598,6268.89551,34.840,
5190.41553,479.598,6268.98730,33.840,
5190.50684,480.598,6269.07861,34.840,
5190.59863,479.598,6269.17041,33.840,
5190.68994,479.598,6269.26172,34.840,
5190.78125,479.598,6269.35352,34.840,
5190.87305,479.598,6269.44482,34.840,
5190.96436,479.598,6269.53613,34.840,
5191.05615,479.598,6269.62793,34.840,
5191.14746,479.598,6269.71924,34.840,
5191.23926,478.598,6269.81104,34.840,
5191.33057,479.598,6269.90234,33.840,
5191.42236,478.598,6269.99414,33.840,
5191.51367,478.598,6270.08545,34.840,
5191.60498,478.598,6270.17725,33.840,
5191.69678,478.598,6270.26855,34.840,
5191.78809,478.598,6270.35986,34.840,
5191.87988,478.598,6270.45166,33.840,
5191.97119,478.598,6270.54297,33.840,
5192.06299,478.598,6270.63477,33.840,
5192.15430,478.598,6270.72607,34.840,
5192.24561,478.598,6270.81787,34.840,
5192.33740,479.598,6270.90918,33.840,
5192.42871,479.598,6271.00049,33.840,
5192.52051,480.598,6271.09229,33.840,
5192.61182,480.598,6271.18359,34.840,
5192.70361,480.598,6271.27539,34.840,
5192.79492,480.598,6271.36670,34.840,
5192.88623,479.598,6271.45850,33.840,
5192.97803,479.598,6271.54980,33.840,
5193.06934,479.598,6271.64111,34.840,
5193.16113,479.598,6271.73291,33.840,
5193.25244,479.598,6271.82422,33.840,
5193.34424,478.598,6271.91602,34.840,
5193.43555,479.598,6272.00732,34.840,
5193.52734,478.598,6272.09912,33.840,
5193.61865,477.598,6272.19043,33.840,
5193.70996,478.598,6272.28223,33.840,
5193.80176,477.598,6272.37354,33.840,
5193.89307,477.598,6272.46484,33.840,
5193.98486,476.598,6272.55664,34.840,
5194.07617,476.598,6272.64795,34.840,
5194.16797,476.598,6272.73975,33.840,
5194.25928,475.598,6272.83105,33.840,
5194.35059,475.598,6272.92285,33.840,
5194.44238,475.598,6273.01416,33.840,
5194.53369,474.598,6273.10547,33.840,
5194.62549,474.598,6273.19727,34.840,
5194.71680,473.598,6273.28857,33.840,
5194.80859,472.598,6273.38037,33.840,
5194.89990,472.598,6273.47168,33.840,
5194.99121,472.598,6273.56348,33.840,
5195.08301,471.598,6273.65479,33.840,
5195.17432,471.598,6273.74609,33.840,
5195.26611,471.598,6273.83789,33.840,
5195.35742,471.598,6273.92920,33.840,
5195.44922,472.598,6274.02100,33.840,
5195.54053,472.598,6274.11230,34.840,
5195.63184,472.598,6274.20410,33.840,
5195.72363,472.598,6274.29541,33.840,
5195.81494,472.598,6274.38721,33.840,
5195.90674,472.598,6274.47852,33.840,
5195.99805,472.598,6274.56982,33.840,
5196.08984,472.598,6274.66162,33.840,
5196.18115,472.598,6274.75293,33.840,
5196.27295,473.598,6274.84473,32.840,
5196.36426,473.598,6274.93604,33.840,
5196.45557,473.598,6275.02783,33.840,
5196.54736,473.598,6275.11914,32.840,
5196.63867,472.598,6275.21045,33.840,
5196.73047,473.598,6275.30225,33.840,
5196.82178,473.598,6275.39355,33.840,
5196.91357,473.598,6275.48535,32.840,
5197.00488,472.598,6275.57666,33.840,
5197.09619,473.598,6275.66846,33.840,
5197.18799,472.598,6275.75977,33.840,
5197.27930,472.598,6275.85107,33.840,
5197.37109,472.598,6275.94287,33.840,
5197.46240,472.598,6276.03418,33.840,
5197.55420,472.598,6276.12598,33.840,
5197.64551,472.598,6276.21729,33.840,
5197.73682,472.598,6276.30908,33.840,
5197.82861,472.598,6276.40039,33.840,
5197.91992,472.598,6276.49219,33.840,
5198.01172,471.598,6276.58350,33.840,
5198.10303,471.598,6276.67480,33.840,
5198.19482,471.598,6276.76660,32.840,
5198.28613,471.598,6276.85791,33.840,
5198.37793,471.598,6276.94971,33.840,
5198.46924,470.598,6277.04102,33.840,
5198.56055,471.598,6277.13281,33.840,
5198.65234,471.598,6277.22412,33.840,
5198.74365,471.598,6277.31543,33.840,
5198.83545,471.598,6277.40723,33.840,
5198.92676,471.598,6277.49854,33.840,
5199.01855,470.598,6277.59033,32.840,
5199.10986,470.598,6277.68164,32.840,
5199.20117,470.598,6277.77344,33.840,
5199.29297,471.598,6277.86475,32.840,
5199.38428,470.598,6277.95605,33.840,
5199.47607,470.598,6278.04785,32.840,
5199.56738,470.598,6278.13916,32.840,
5199.65918,470.598,6278.23096,32.840,
5199.75049,470.598,6278.32227,32.840,
5199.84180,470.598,6278.41406,32.840,
5199.93359,469.598,6278.50537,31.840,
5200.02490,469.598,6278.59668,31.840,
5200.11670,469.598,6278.68848,30.840,
5200.20801,469.598,6278.77979,30.840,
5200.29980,469.598,6278.87158,30.840,
5200.39111,469.598,6278.96289,30.840,
5200.48291,469.598,6279.05469,31.840,
5200.57422,469.598,6279.14600,30.840,
5200.66553,468.598,6279.23779,31.840,
5200.75732,469.598,6279.32910,31.840,
5200.84863,468.598,6279.42041,31.840,
5200.94043,468.598,6279.51221,32.840,
5201.03174,469.598,6279.60352,32.840,
5201.12354,468.598,6279.69531,32.840,
5201.21484,468.598,6279.78662,32.840,
5201.30615,468.598,6279.87842,32.840,
5201.39795,468.598,6279.96973,33.840,
5201.48926,468.598,6280.06104,32.840,
5201.58105,468.598,6280.15283,33.840,
5201.67236,467.598,6280.24414,32.840,
5201.76416,467.598,6280.33594,32.840,
5201.85547,467.598,6280.42725,32.840,
5201.94678,467.598,6280.51904,32.840,
5202.03857,467.598,6280.61035,32.840,
5202.12988,467.598,6280.70166,31.840,
5202.22168,467.598,6280.79346,31.840,
5202.31299,467.598,6280.88477,30.840,
5202.40479,467.598,6280.97656,29.840,
5202.49609,467.598,6281.06787,29.840,
5202.58789,467.598,6281.15967,29.840,
5202.67920,467.598,6281.25098,29.840,
5202.77051,466.598,6281.34277,28.840,
5202.86230,466.598,6281.43408,29.840,
5202.95361,466.598,6281.52539,28.840,
5203.04541,466.598,6281.61719,28.840,
5203.13672,466.598,6281.70850,29.840,
5203.22852,466.598,6281.80029,29.840,
5203.31982,465.598,6281.89160,29.840,
5203.41113,465.598,6281.98340,30.840,
5203.50293,465.598,6282.07471,31.840,
5203.59424,465.598,6282.16602,31.840,
5203.68604,466.598,6282.25781,30.840,
5203.77734,465.598,6282.34912,31.840,
5203.86914,465.598,6282.44092,31.840,
5203.96045,465.598,6282.53223,31.840,
5204.05176,465.598,6282.62402,31.840,
5204.14355,465.598,6282.71533,31.840,
5204.23486,465.598,6282.80664,32.840,
5204.32666,464.598,6282.89844,32.840,
5204.41797,464.598,6282.98975,31.840,
5204.50977,464.598,6283.08154,32.840,
5204.60107,464.598,6283.17285,31.840,
5204.69287,464.598,6283.26465,32.840,
5204.78418,464.598,6283.35596,32.840,
5204.87549,464.598,6283.44775,32.840,
5204.96729,464.598,6283.53906,32.840,
5205.05859,464.598,6283.63037,32.840,
5205.15039,464.598,6283.72217,32.840,
5205.24170,463.598,6283.81348,32.840,
5205.33350,464.598,6283.90527,32.840,
5205.42480,464.598,6283.99658,32.840,
5205.51611,463.598,6284.08838,32.840,
5205.60791,463.598,6284.17969,32.840,
5205.69922,463.598,6284.27100,32.840,
5205.79102,462.598,6284.36279,32.840,
5205.88232,462.598,6284.45410,32.840,
5205.97412,462.598,6284.54590,32.840,
5206.06543,462.598,6284.63721,32.840,
5206.15674,462.598,6284.72900,31.840,
5206.24854,463.598,6284.82031,32.840,
5206.33984,462.598,6284.91162,32.840,
5206.43164,462.598,6285.00342,32.840,
5206.52295,462.598,6285.09473,32.840,
5206.61475,463.598,6285.18652,31.840,
5206.70605,462.598,6285.27783,31.840,
5206.79736,462.598,6285.36963,31.840,
5206.88916,462.598,6285.46094,32.840,
5206.98047,462.598,6285.55273,31.840,
5207.07227,461.598,6285.64404,31.840,
5207.16357,461.598,6285.73535,31.840,
5207.25537,461.598,6285.82715,32.840,
5207.34668,461.598,6285.91846,31.840,
5207.43848,461.598,6286.01025,32.840,
5207.52979,461.598,6286.10156,31.840,
5207.62109,460.598,6286.19336,31.840,
5207.71289,460.598,6286.28467,31.840,
5207.80420,461.598,6286.37598,31.840,
5207.89600,460.598,6286.46777,31.840,
5207.98730,460.598,6286.55908,31.840,
5208.07910,461.598,6286.65088,32.840,
5208.17041,460.598,6286.74219,31.840,
5208.26172,460.598,6286.83398,31.840,
5208.35352,460.598,6286.92529,31.840,
5208.44482,459.598,6287.01660,31.840,
5208.53662,459.598,6287.10840,31.840,
5208.62793,460.598,6287.19971,31.840,
5208.71973,460.598,6287.29150,32.840,
5208.81104,459.598,6287.38281,31.840,
5208.90234,459.598,6287.47461,31.840,
5208.99414,459.598,6287.56592,31.840,
5209.08545,459.598,6287.65771,31.840,
5209.17725,459.598,6287.74902,31.840,
5209.26855,459.598,6287.84033,31.840,
5209.36035,459.598,6287.93213,31.840,
5209.45166,458.598,6288.02344,31.840,
5209.54346,459.598,6288.11523,31.840,
5209.63477,458.598,6288.20654,31.840,
5209.72607,458.598,6288.29834,31.840,
5209.81787,458.598,6288.38965,31.840,
5209.90918,458.598,6288.48096,31.840,
5210.00098,459.598,6288.57275,31.840,
5210.09229,458.598,6288.66406,31.840,
5210.18408,459.598,6288.75586,31.840,
5210.27539,458.598,6288.84717,31.840,
5210.36670,458.598,6288.93896,31.840,
5210.45850,458.598,6289.03027,31.840,
5210.54980,458.598,6289.12158,31.840,
5210.64160,457.598,6289.21338,32.840,
5210.73291,457.598,6289.30469,31.840,
5210.82471,457.598,6289.39648,31.840,
5210.91602,457.598,6289.48779,31.840,
5211.00732,457.598,6289.57959,31.840,
5211.09912,457.598,6289.67090,31.840,
5211.19043,457.598,6289.76270,31.840,
5211.28223,457.598,6289.85400,31.840,
5211.37354,456.598,6289.94531,30.840,
5211.46533,457.598,6290.03711,31.840,
5211.55664,457.598,6290.12842,30.840,
5211.64844,456.598,6290.22021,31.840,
5211.73975,457.598,6290.31152,31.840,
5211.83105,456.598,6290.40332,31.840,
5211.92285,456.598,6290.49463,31.840,
5212.01416,456.598,6290.58594,30.840,
5212.10596,455.598,6290.67773,31.840,
5212.19727,455.598,6290.76904,31.840,
5212.28906,454.598,6290.86084,30.840,
5212.38037,454.598,6290.95215,30.840,
5212.47168,454.598,6291.04395,30.840,
5212.56348,453.598,6291.13525,30.840,
5212.65479,452.598,6291.22656,30.840,
5212.74658,451.598,6291.31836,30.840,
5212.83789,451.598,6291.40967,30.840,
5212.92969,451.598,6291.50146,30.840,
5213.02100,451.598,6291.59277,30.840,
5213.11230,451.598,6291.68457,31.840,
5213.20410,451.598,6291.77588,30.840,
5213.29541,451.598,6291.86719,31.840,
5213.38721,451.598,6291.95898,30.840,
5213.47852,452.598,6292.05029,30.840,
5213.57031,451.598,6292.14209,31.840,
5213.66162,452.598,6292.23340,30.840,
5213.75342,452.598,6292.32520,30.840,
5213.84473,453.598,6292.41650,30.840,
5213.93604,453.598,6292.50830,30.840,
5214.02783,453.598,6292.59961,30.840,
5214.11914,453.598,6292.69092,30.840,
5214.21094,453.598,6292.78271,30.840,
5214.30225,453.598,6292.87402,30.840,
5214.39404,453.598,6292.96582,30.840,
5214.48535,453.598,6293.05713,30.840,
5214.57666,453.598,6293.14893,31.840,
5214.66846,453.598,6293.24023,30.840,
5214.75977,453.598,6293.33154,30.840,
5214.85156,453.598,6293.42334,30.840,
5214.94287,453.598,6293.51465,31.840,
5215.03467,453.598,6293.60645,30.840,
5215.12598,453.598,6293.69775,30.840,
5215.21729,452.598,6293.78955,31.840,
5215.30908,452.598,6293.88086,30.840,
5215.40039,453.598,6293.97217,30.840,
5215.49219,452.598,6294.06396,30.840,
5215.58350,452.598,6294.15527,30.840,
5215.67529,452.598,6294.24707,30.840,
5215.76660,452.598,6294.33838,30.840,
5215.85840,451.598,6294.43018,30.840,
5215.94971,451.598,6294.52148,30.840,
5216.04102,451.598,6294.61328,31.840,
5216.13281,451.598,6294.70459,30.840,
5216.22412,451.598,6294.79590,30.840,
5216.31592,451.598,6294.88770,30.840,
5216.40723,451.598,6294.97900,30.840,
5216.49902,451.598,6295.07080,30.840,
5216.59033,451.598,6295.16211,30.840,
5216.68164,450.598,6295.25391,30.840,
5216.77344,450.598,6295.34521,30.840,
5216.86475,450.598,6295.43652,30.840,
5216.95654,450.598,6295.52832,30.840,
5217.04785,450.598,6295.61963,30.840,
5217.13965,450.598,6295.71143,30.840,
5217.23096,450.598,6295.80273,29.840,
5217.32227,450.598,6295.89453,29.840,
5217.41406,450.598,6295.98584,30.840,
5217.50537,450.598,6296.07715,30.840,
5217.59717,450.598,6296.16895,30.840,
5217.68848,449.598,6296.26025,30.840,
5217.78027,449.598,6296.35205,30.840,
5217.87158,449.598,6296.44336,29.840,
5217.96338,449.598,6296.53516,30.840,
5218.05469,449.598,6296.62646,30.840,
5218.14600,449.598,6296.71826,30.840,
5218.23779,449.598,6296.80957,31.840,
5218.32910,449.598,6296.90088,31.840,
5218.42090,448.598,6296.99268,31.840,
5218.51221,448.598,6297.08398,32.840,
5218.60400,448.598,6297.17578,32.840,
5218.69531,448.598,6297.26709,32.840,
5218.78662,448.598,6297.35889,32.840,
5218.87842,448.598,6297.45020,32.840,
5218.96973,448.598,6297.54150,32.840,
5219.06152,448.598,6297.63330,32.840,
5219.15283,448.598,6297.72461,31.840,
5219.24463,448.598,6297.81641,31.840,
5219.33594,448.598,6297.90771,31.840,
5219.42725,448.598,6297.99951,31.840,
5219.51904,447.598,6298.09082,31.840,
5219.61035,447.598,6298.18213,30.840,
5219.70215,447.598,6298.27393,30.840,
5219.79346,447.598,6298.36523,30.840,
5219.88525,447.598,6298.45703,29.840,
5219.97656,447.598,6298.54834,30.840,
5220.06787,447.598,6298.64014,30.840,
5220.15967,446.598,6298.73145,29.840,
5220.25098,446.598,6298.82324,29.840,
5220.34277,446.598,6298.91455,29.840,
5220.43408,446.598,6299.00586,29.840,
5220.52588,446.598,6299.09766,28.840,
5220.61719,446.598,6299.18896,29.840,
5220.70898,446.598,6299.28076,28.840,
5220.80029,445.598,6299.37207,27.840,
5220.89160,446.598,6299.46387,27.840,
5220.98340,445.598,6299.55518,27.840,
5221.07471,445.598,6299.64648,27.840,
5221.16650,446.598,6299.73828,26.840,
5221.25781,446.598,6299.82959,26.840,
5221.34961,445.598,6299.92139,26.840,
5221.44092,445.598,6300.01270,26.840,
5221.53223,445.598,6300.10449,27.840,
5221.62402,445.598,6300.19580,27.840,
5221.71533,445.598,6300.28711,28.840,
5221.80713,445.598,6300.37891,27.840,
5221.89844,445.598,6300.47021,28.840,
5221.99023,445.598,6300.56201,28.840,
5222.08154,444.598,6300.65332,28.840,
5222.17285,444.598,6300.74512,28.840,
5222.26465,444.598,6300.83643,28.840,
5222.35596,444.598,6300.92822,28.840,
5222.44775,444.598,6301.01953,29.840,
5222.53906,444.598,6301.11084,29.840,
5222.63086,444.598,6301.20264,29.840,
5222.72217,445.598,6301.29395,29.840,
5222.81396,444.598,6301.38574,29.840,
5222.90527,444.598,6301.47705,29.840,
5222.99658,444.598,6301.56885,29.840,
5223.08838,443.598,6301.66016,29.840,
5223.17969,443.598,6301.75146,29.840,
5223.27148,443.598,6301.84326,29.840,
5223.36279,443.598,6301.93457,30.840,
5223.45459,443.598,6302.02637,29.840,
5223.54590,442.598,6302.11768,29.840,
5223.63721,442.598,6302.20947,29.840,
5223.72900,443.598,6302.30078,29.840,
5223.82031,442.598,6302.39209,29.840,
5223.91211,442.598,6302.48389,29.840,
5224.00342,442.598,6302.57520,29.840,
5224.09521,442.598,6302.66699,29.840,
5224.18652,443.598,6302.75830,29.840,
5224.27783,442.598,6302.85010,29.840,
5224.36963,442.598,6302.94141,29.840,
5224.46094,442.598,6303.03320,29.840,
5224.55273,441.598,6303.12451,28.840,
5224.64404,442.598,6303.21582,28.840,
5224.73584,441.598,6303.30762,29.840,
5224.82715,441.598,6303.39893,29.840,
5224.91895,442.598,6303.49072,29.840,
5225.01025,441.598,6303.58203,29.840,
5225.10156,441.598,6303.67383,28.840,
5225.19336,441.598,6303.76514,29.840,
5225.28467,441.598,6303.85645,29.840,
5225.37646,441.598,6303.94824,29.840,
5225.46777,440.598,6304.03955,29.840,
5225.55957,440.598,6304.13135,29.840,
5225.65088,441.598,6304.22266,28.840,
5225.74219,440.598,6304.31445,28.840,
5225.83398,440.598,6304.40576,29.840,
5225.92529,440.598,6304.49707,29.840,
5226.01709,440.598,6304.58887,28.840,
5226.10840,440.598,6304.68018,28.840,
5226.20020,440.598,6304.77197,28.840,
5226.29150,440.598,6304.86328,29.840,
5226.38281,440.598,6304.95508,28.840,
5226.47461,439.598,6305.04639,28.840,
5226.56592,439.598,6305.13770,29.840,
5226.65771,440.598,6305.22949,28.840,
5226.74902,440.598,6305.32080,29.840,
5226.84082,439.598,6305.41260,28.840,
5226.93213,439.598,6305.50391,28.840,
5227.02393,439.598,6305.59570,28.840,
5227.11523,439.598,6305.68701,28.840,
5227.20654,438.598,6305.77881,28.840,
5227.29834,439.598,6305.87012,28.840,
5227.38965,439.598,6305.96143,28.840,
5227.48145,438.598,6306.05322,28.840,
5227.57275,439.598,6306.14453,28.840,
5227.66455,439.598,6306.23633,28.840,
5227.75586,438.598,6306.32764,29.840,
5227.84717,439.598,6306.41943,28.840,
5227.93896,438.598,6306.51074,28.840,
5228.03027,438.598,6306.60205,29.840,
5228.12207,438.598,6306.69385,29.840,
5228.21338,438.598,6306.78516,28.840,
5228.30518,438.598,6306.87695,28.840,
5228.39648,438.598,6306.96826,28.840,
5228.48779,438.598,6307.06006,28.840,
5228.57959,437.598,6307.15137,28.840,
5228.67090,437.598,6307.24268,29.840,
5228.76270,437.598,6307.33447,28.840,
5228.85400,437.598,6307.42578,28.840,
5228.94580,437.598,6307.51758,29.840,
5229.03711,437.598,6307.60889,28.840,
5229.12891,437.598,6307.70068,28.840,
5229.22021,437.598,6307.79199,29.840,
5229.31152,437.598,6307.88379,28.840,
5229.40332,436.598,6307.97510,28.840,
5229.49463,436.598,6308.06641,28.840,
5229.58643,436.598,6308.15820,28.840,
5229.67773,436.598,6308.24951,28.840,
5229.76953,436.598,6308.34131,28.840,
5229.86084,436.598,6308.43262,28.840,
5229.95215,436.598,6308.52441,28.840,
5230.04395,436.598,6308.61572,27.840,
5230.13525,436.598,6308.70703,28.840,
5230.22705,436.598,6308.79883,28.840,
5230.31836,435.598,6308.89014,27.840,
5230.41016,436.598,6308.98193,28.840,
5230.50146,435.598,6309.07324,28.840,
5230.59277,435.598,6309.16504,28.840,
5230.68457,436.598,6309.25635,28.840,
5230.77588,436.598,6309.34766,28.840,
5230.86768,436.598,6309.43945,28.840,
5230.95898,436.598,6309.53076,28.840,
5231.05078,436.598,6309.62256,28.840,
5231.14209,436.598,6309.71387,28.840,
5231.23340,435.598,6309.80566,28.840,
5231.32520,435.598,6309.89697,27.840,
5231.41650,435.598,6309.98877,28.840,
5231.50830,435.598,6310.08008,27.840,
5231.59961,435.598,6310.17139,27.840,
5231.69141,435.598,6310.26318,28.840,
5231.78271,434.598,6310.35449,28.840,
5231.87451,434.598,6310.44629,27.840,
5231.96582,434.598,6310.53760,27.840,
5232.05713,434.598,6310.62939,27.840,
5232.14893,434.598,6310.72070,28.840,
5232.24023,434.598,6310.81201,27.840,
5232.33203,433.598,6310.90381,28.840,
5232.42334,433.598,6310.99512,28.840,
5232.51514,433.598,6311.08691,28.840,
5232.60645,433.598,6311.17822,28.840,
5232.69775,432.598,6311.27002,27.840,
5232.78955,433.598,6311.36133,27.840,
5232.88086,433.598,6311.45264,27.840,
5232.97266,433.598,6311.54443,28.840,
5233.06396,433.598,6311.63574,27.840,
5233.15576,432.598,6311.72754,27.840,
5233.24707,432.598,6311.81885,28.840,
5233.33838,432.598,6311.91064,27.840,
5233.43018,432.598,6312.00195,27.840,
5233.52148,432.598,6312.09375,27.840,
5233.61328,432.598,6312.18506,28.840,
5233.70459,432.598,6312.27637,27.840,
5233.79639,431.598,6312.36816,27.840,
5233.88770,431.598,6312.45947,27.840,
5233.97949,431.598,6312.55127,27.840,
5234.07080,431.598,6312.64258,27.840,
5234.16211,431.598,6312.73438,27.840,
5234.25391,431.598,6312.82568,27.840,
5234.34521,431.598,6312.91699,27.840,
5234.43701,431.598,6313.00879,27.840,
5234.52832,431.598,6313.10010,28.840,
5234.62012,431.598,6313.19189,27.840,
5234.71143,431.598,6313.28320,27.840,
5234.80273,430.598,6313.37500,27.840,
5234.89453,430.598,6313.46631,27.840,
5234.98584,430.598,6313.55762,28.840,
5235.07764,430.598,6313.64941,28.840,
5235.16895,430.598,6313.74072,27.840,
5235.26074,431.598,6313.83252,27.840,
5235.35205,430.598,6313.92383,27.840,
5235.44336,430.598,6314.01563,27.840,
5235.53516,430.598,6314.10693,27.840,
5235.62646,430.598,6314.19873,27.840,
5235.71826,429.598,6314.29004,27.840,
5235.80957,429.598,6314.38135,27.840,
5235.90137,430.598,6314.47314,27.840,
5235.99268,429.598,6314.56445,27.840,
5236.08447,429.598,6314.65625,27.840,
5236.17578,429.598,6314.74756,27.840,
5236.26709,429.598,6314.83936,27.840,
5236.35889,429.598,6314.93066,27.840,
5236.45020,429.598,6315.02197,27.840,
5236.54199,429.598,6315.11377,27.840,
5236.63330,428.598,6315.20508,27.840,
5236.72510,428.598,6315.29688,27.840,
5236.81641,428.598,6315.38818,26.840,
5236.90771,429.598,6315.47998,27.840,
5236.99951,428.598,6315.57129,27.840,
5237.09082,428.598,6315.66260,26.840,
5237.18262,428.598,6315.75439,26.840,
5237.27393,427.598,6315.84570,27.840,
5237.36572,429.598,6315.93750,26.840,
5237.45703,428.598,6316.02881,26.840,
5237.54834,428.598,6316.12061,27.840,
5237.64014,427.598,6316.21191,26.840,
5237.73145,427.598,6316.30322,26.840,
5237.82324,427.598,6316.39502,26.840,
5237.91455,427.598,6316.48633,26.840,
5238.00635,427.598,6316.57813,26.840,
5238.09766,426.598,6316.66943,26.840,
5238.18945,426.598,6316.76123,26.840,
5238.28076,426.598,6316.85254,26.840,
5238.37207,426.598,6316.94434,26.840,
5238.46387,426.598,6317.03564,27.840,
5238.55518,426.598,6317.12695,26.840,
5238.64697,426.598,6317.21875,26.840,
5238.73828,426.598,6317.31006,26.840,
5238.83008,426.598,6317.40186,26.840,
5238.92139,426.598,6317.49316,26.840,
5239.01270,426.598,6317.58496,26.840,
5239.10449,426.598,6317.67627,27.840,
5239.19580,426.598,6317.76758,27.840,
5239.28760,426.598,6317.85938,27.840,
5239.37891,426.598,6317.95068,28.840,
5239.47070,426.598,6318.04248,29.840,
5239.56201,426.598,6318.13379,29.840,
5239.65332,426.598,6318.22559,29.840,
5239.74512,425.598,6318.31689,29.840,
5239.83643,425.598,6318.40820,28.840,
5239.92822,425.598,6318.50000,28.840,
5240.01953,425.598,6318.59131,28.840,
5240.11133,425.598,6318.68311,28.840,
5240.20264,424.598,6318.77441,28.840,
5240.29443,425.598,6318.86621,27.840,
5240.38574,424.598,6318.95752,27.840,
5240.47705,424.598,6319.04932,27.840,
5240.56885,424.598,6319.14063,27.840,
5240.66016,424.598,6319.23193,27.840,
5240.75195,424.598,6319.32373,27.840,
5240.84326,424.598,6319.41504,27.840,
5240.93506,424.598,6319.50684,27.840,
5241.02637,424.598,6319.59814,27.840,
5241.11768,424.598,6319.68994,26.840,
5241.20947,423.598,6319.78125,27.840,
5241.30078,423.598,6319.87256,26.840,
5241.39258,423.598,6319.96436,25.840,
5241.48389,423.598,6320.05566,26.840,
5241.57568,423.598,6320.14746,26.840,
5241.66699,423.598,6320.23877,26.840,
5241.75830,423.598,6320.33057,26.840,
5241.85010,423.598,6320.42188,26.840,
5241.94141,423.598,6320.51318,26.840,
5242.03320,423.598,6320.60498,26.840,
5242.12451,423.598,6320.69629,26.840,
5242.21631,422.598,6320.78809,26.840,
5242.30762,422.598,6320.87939,26.840,
5242.39941,422.598,6320.97119,26.840,
5242.49072,422.598,6321.06250,26.840,
5242.58203,422.598,6321.15430,27.840,
5242.67383,422.598,6321.24561,26.840,
5242.76514,421.598,6321.33691,26.840,
5242.85693,422.598,6321.42871,26.840,
5242.94824,422.598,6321.52002,25.840,
5243.04004,421.598,6321.61182,26.840,
5243.13135,422.598,6321.70313,25.840,
5243.22266,422.598,6321.79492,26.840,
5243.31445,422.598,6321.88623,25.840,
5243.40576,421.598,6321.97754,26.840,
5243.49756,421.598,6322.06934,25.840,
5243.58887,421.598,6322.16064,26.840,
5243.68066,421.598,6322.25244,26.840,
5243.77197,421.598,6322.34375,26.840,
5243.86328,421.598,6322.43555,26.840,
5243.95508,421.598,6322.52686,26.840,
5244.04639,421.598,6322.61816,26.840,
5244.13818,421.598,6322.70996,25.840,
5244.22949,420.598,6322.80127,26.840,
5244.32129,420.598,6322.89307,26.840,
5244.41260,420.598,6322.98438,25.840,
5244.50391,420.598,6323.07617,25.840,
5244.59570,420.598,6323.16748,26.840,
5244.68701,420.598,6323.25928,26.840,
5244.77881,420.598,6323.35059,25.840,
5244.87012,420.598,6323.44189,25.840,
5244.96191,420.598,6323.53369,26.840,
5245.05322,420.598,6323.62500,25.840,
5245.14502,419.598,6323.71680,25.840,
5245.23633,419.598,6323.80811,26.840,
5245.32764,420.598,6323.89990,25.840,
5245.41943,419.598,6323.99121,25.840,
5245.51074,419.598,6324.08252,25.840,
5245.60254,419.598,6324.17432,26.840,
5245.69385,419.598,6324.26563,26.840,
5245.78564,419.598,6324.35742,25.840,
5245.87695,419.598,6324.44873,25.840,
5245.96826,419.598,6324.54053,25.840,
5246.06006,418.598,6324.63184,26.840,
5246.15137,419.598,6324.72314,25.840,
5246.24316,418.598,6324.81494,26.840,
5246.33447,418.598,6324.90625,26.840,
5246.42627,418.598,6324.99805,25.840,
5246.51758,417.598,6325.08936,25.840,
5246.60889,417.598,6325.18115,25.840,
5246.70068,417.598,6325.27246,25.840,
5246.79199,418.598,6325.36426,26.840,
5246.88379,417.598,6325.45557,25.840,
5246.97510,417.598,6325.54688,25.840,
5247.06689,417.598,6325.63867,25.840,
5247.15820,417.598,6325.72998,25.840,
5247.25000,417.598,6325.82178,25.840,
5247.34131,417.598,6325.91309,25.840,
5247.43262,417.598,6326.00488,26.840,
5247.52441,417.598,6326.09619,25.840,
5247.61572,417.598,6326.18750,25.840,
5247.70752,417.598,6326.27930,25.840,
5247.79883,417.598,6326.37061,25.840,
5247.89063,417.598,6326.46240,25.840,
5247.98193,416.598,6326.55371,25.840,
5248.07324,417.598,6326.64551,25.840,
5248.16504,416.598,6326.73682,24.840,
5248.25635,416.598,6326.82813,26.840,
5248.34814,416.598,6326.91992,25.840,
5248.43945,415.598,6327.01123,25.840,
5248.53125,414.598,6327.10303,25.840,
5248.62256,414.598,6327.19434,25.840,
5248.71387,415.598,6327.28613,25.840,
5248.80566,414.598,6327.37744,25.840,
5248.89697,414.598,6327.46924,25.840,
5248.98877,415.598,6327.56055,25.840,
5249.08008,415.598,6327.65186,25.840,
5249.17188,415.598,6327.74365,25.840,
5249.26318,416.598,6327.83496,25.840,
5249.35498,416.598,6327.92676,24.840,
5249.44629,415.598,6328.01807,25.840,
5249.53760,415.598,6328.10986,25.840,
5249.62939,415.598,6328.20117,25.840,
5249.72070,415.598,6328.29248,25.840,
5249.81250,415.598,6328.38428,25.840,
5249.90381,415.598,6328.47559,25.840,
5249.99561,415.598,6328.56738,25.840,
5250.08691,414.598,6328.65869,25.840,
5250.17822,414.598,6328.75049,25.840,
5250.27002,414.598,6328.84180,25.840,
5250.36133,414.598,6328.93311,25.840,
5250.45313,414.598,6329.02490,25.840,
5250.54443,414.598,6329.11621,24.840,
5250.63623,414.598,6329.20801,25.840,
5250.72754,414.598,6329.29932,25.840,
5250.81885,414.598,6329.39111,25.840,
5250.91064,414.598,6329.48242,24.840,
5251.00195,413.598,6329.57373,25.840,
5251.09375,413.598,6329.66553,24.840,
5251.18506,413.598,6329.75684,25.840,
5251.27686,413.598,6329.84863,24.840,
5251.36816,413.598,6329.93994,24.840,
5251.45996,413.598,6330.03174,24.840,
5251.55127,413.598,6330.12305,24.840,
5251.64258,412.598,6330.21484,24.840,
5251.73438,412.598,6330.30615,24.840,
5251.82568,412.598,6330.39746,24.840,
5251.91748,412.598,6330.48926,24.840,
5252.00879,413.598,6330.58057,24.840,
5252.10059,412.598,6330.67236,24.840,
5252.19189,412.598,6330.76367,24.840,
5252.28320,412.598,6330.85547,24.840,
5252.37500,413.598,6330.94678,24.840,
5252.46631,412.598,6331.03809,24.840,
5252.55811,412.598,6331.12988,24.840,
5252.64941,412.598,6331.22119,25.840,
5252.74121,412.598,6331.31299,24.840,
5252.83252,411.598,6331.40430,24.840,
5252.92383,411.598,6331.49609,24.840,
5253.01563,411.598,6331.58740,24.840,
5253.10693,411.598,6331.67871,24.840,
5253.19873,411.598,6331.77051,24.840,
5253.29004,411.598,6331.86182,24.840,
5253.38184,411.598,6331.95361,24.840,
5253.47314,411.598,6332.04492,24.840,
5253.56494,410.598,6332.13672,24.840,
5253.65625,410.598,6332.22803,24.840,
5253.74756,410.598,6332.31982,24.840,
5253.83936,410.598,6332.41113,24.840,
5253.93066,410.598,6332.50244,24.840,
5254.02246,410.598,6332.59424,24.840,
5254.11377,410.598,6332.68555,25.840,
5254.20557,410.598,6332.77734,24.840,
5254.29688,409.598,6332.86865,24.840,
5254.38818,409.598,6332.96045,24.840,
5254.47998,409.598,6333.05176,24.840,
5254.57129,409.598,6333.14307,24.840,
5254.66309,409.598,6333.23486,24.840,
5254.75439,409.598,6333.32617,24.840,
5254.84619,409.598,6333.41797,24.840,
5254.93750,409.598,6333.50928,24.840,
5255.02881,409.598,6333.60107,24.840,
5255.12061,409.598,6333.69238,24.840,
5255.21191,409.598,6333.78369,23.840,
5255.30371,409.598,6333.87549,24.840,
5255.39502,409.598,6333.96680,24.840,
5255.48682,408.598,6334.05859,24.840,
5255.57813,409.598,6334.14990,25.840,
5255.66992,408.598,6334.24170,25.840,
5255.76123,408.598,6334.33301,25.840,
5255.85254,408.598,6334.42480,26.840,
5255.94434,408.598,6334.51611,26.840,
5256.03564,408.598,6334.60742,26.840,
5256.12744,408.598,6334.69922,26.840,
5256.21875,407.598,6334.79053,26.840,
5256.31055,408.598,6334.88232,25.840,
5256.40186,408.598,6334.97363,26.840,
5256.49316,407.598,6335.06543,26.840,
5256.58496,407.598,6335.15674,25.840,
5256.67627,407.598,6335.24805,25.840,
5256.76807,407.598,6335.33984,25.840,
5256.85938,407.598,6335.43115,25.840,
5256.95117,407.598,6335.52295,25.840,
5257.04248,407.598,6335.61426,25.840,
5257.13379,407.598,6335.70605,24.840,
5257.22559,407.598,6335.79736,24.840,
5257.31689,406.598,6335.88867,24.840,
5257.40869,406.598,6335.98047,24.840,
5257.50000,407.598,6336.07178,24.840,
5257.59180,406.598,6336.16357,24.840,
5257.68311,406.598,6336.25488,24.840,
5257.77441,406.598,6336.34668,24.840,
5257.86621,407.598,6336.43799,23.840,
5257.95752,406.598,6336.52979,23.840,
5258.04932,406.598,6336.62109,23.840,
5258.14063,406.598,6336.71240,23.840,
5258.23242,405.598,6336.80420,23.840,
5258.32373,405.598,6336.89551,23.840,
5258.41553,406.598,6336.98730,23.840,
5258.50684,406.598,6337.07861,24.840,
5258.59814,405.598,6337.17041,23.840,
5258.68994,405.598,6337.26172,23.840,
5258.78125,405.598,6337.35303,23.840,
5258.87305,405.598,6337.44482,23.840,
5258.96436,405.598,6337.53613,23.840,
5259.05615,405.598,6337.62793,23.840,
5259.14746,405.598,6337.71924,22.840,
5259.23877,404.598,6337.81104,23.840,
5259.33057,405.598,6337.90234,23.840,
5259.42188,404.598,6337.99365,22.840,
5259.51367,404.598,6338.08545,23.840,
5259.60498,404.598,6338.17676,23.840,
5259.69678,404.598,6338.26855,23.840,
5259.78809,404.598,6338.35986,23.840,
5259.87939,403.598,6338.45166,23.840,
5259.97119,404.598,6338.54297,24.840,
5260.06250,404.598,6338.63477,23.840,
5260.15430,403.598,6338.72607,23.840,
5260.24561,403.598,6338.81738,23.840,
5260.33740,403.598,6338.90918,23.840,
5260.42871,403.598,6339.00049,23.840,
5260.52051,403.598,6339.09229,23.840,
5260.61182,403.598,6339.18359,23.840,
5260.70313,403.598,6339.27539,23.840,
5260.79492,403.598,6339.36670,23.840,
5260.88623,403.598,6339.45801,23.840,
5260.97803,402.598,6339.54980,23.840,
5261.06934,403.598,6339.64111,23.840,
5261.16113,403.598,6339.73291,23.840,
5261.25244,403.598,6339.82422,23.840,
5261.34375,402.598,6339.91602,22.840,
5261.43555,402.598,6340.00732,23.840,
5261.52686,402.598,6340.09863,22.840,
5261.61865,402.598,6340.19043,23.840,
5261.70996,401.598,6340.28174,22.840,
5261.80176,402.598,6340.37354,23.840,
5261.89307,402.598,6340.46484,23.840,
5261.98438,401.598,6340.55664,22.840,
5262.07617,401.598,6340.64795,23.840,
5262.16748,402.598,6340.73975,22.840,
5262.25928,402.598,6340.83105,22.840,
5262.35059,401.598,6340.92236,23.840,
5262.44238,401.598,6341.01416,22.840,
5262.53369,401.598,6341.10547,23.840,
5262.62549,400.598,6341.19727,23.840,
5262.71680,401.598,6341.28857,23.840,
5262.80811,401.598,6341.38037,23.840,
5262.89990,400.598,6341.47168,23.840,
5262.99121,400.598,6341.56299,23.840,
5263.08301,401.598,6341.65479,23.840,
5263.17432,400.598,6341.74609,22.840,
5263.26611,400.598,6341.83789,23.840,
5263.35742,400.598,6341.92920,23.840,
5263.44873,400.598,6342.02100,23.840,
5263.54053,400.598,6342.11230,23.840,
5263.63184,400.598,6342.20361,23.840,
5263.72363,400.598,6342.29541,23.840,
5263.81494,400.598,6342.38672,22.840,
5263.90674,400.598,6342.47852,22.840,
5263.99805,399.598,6342.56982,22.840,
5264.08936,400.598,6342.66162,22.840,
5264.18115,400.598,6342.75293,23.840,
5264.27246,400.598,6342.84424,22.840,
5264.36426,400.598,6342.93604,23.840,
5264.45557,400.598,6343.02734,22.840,
5264.54736,400.598,6343.11914,23.840,
5264.63867,399.598,6343.21045,22.840,
5264.73047,399.598,6343.30225,22.840,
5264.82178,399.598,6343.39355,23.840,
5264.91309,399.598,6343.48535,22.840,
5265.00488,398.598,6343.57666,22.840,
5265.09619,398.598,6343.66797,23.840,
5265.18799,399.598,6343.75977,22.840,
5265.27930,398.598,6343.85107,22.840,
5265.37109,398.598,6343.94287,22.840,
5265.46240,398.598,6344.03418,22.840,
5265.55371,398.598,6344.12598,22.840,
5265.64551,398.598,6344.21729,22.840,
5265.73682,398.598,6344.30859,22.840,
5265.82861,398.598,6344.40039,23.840,
5265.91992,397.598,6344.49170,21.840,
5266.01172,397.598,6344.58350,22.840,
5266.10303,397.598,6344.67480,22.840,
5266.19434,396.598,6344.76660,23.840,
5266.28613,396.598,6344.85791,23.840,
5266.37744,395.598,6344.94922,22.840,
5266.46924,395.598,6345.04102,21.840,
5266.56055,394.598,6345.13232,22.840,
5266.65234,394.598,6345.22412,22.840,
5266.74365,394.598,6345.31543,22.840,
5266.83545,394.598,6345.40723,21.840,
5266.92676,394.598,6345.49854,21.840,
5267.01807,395.598,6345.59033,22.840,
5267.10986,395.598,6345.68164,22.840,
5267.20117,394.598,6345.77295,22.840,
5267.29297,395.598,6345.86475,23.840,
5267.38428,395.598,6345.95605,21.840,
5267.47607,394.598,6346.04785,21.840,
5267.56738,395.598,6346.13916,22.840,
5267.65869,395.598,6346.23096,22.840,
5267.75049,395.598,6346.32227,21.840,
5267.84180,395.598,6346.41357,22.840,
5267.93359,395.598,6346.50537,22.840,
5268.02490,395.598,6346.59668,22.840,
5268.11670,395.598,6346.68848,22.840,
5268.20801,394.598,6346.77979,22.840,
5268.29932,394.598,6346.87158,22.840,
5268.39111,394.598,6346.96289,22.840,
5268.48242,394.598,6347.05420,22.840,
5268.57422,395.598,6347.14600,22.840,
5268.66553,394.598,6347.23730,22.840,
5268.75732,394.598,6347.32910,22.840,
5268.84863,394.598,6347.42041,22.840,
5268.93994,394.598,6347.51221,22.840,
5269.03174,394.598,6347.60352,22.840,
5269.12305,394.598,6347.69531,22.840,
5269.21484,394.598,6347.78662,22.840,
5269.30615,393.598,6347.87793,21.840,
5269.39795,393.598,6347.96973,22.840,
5269.48926,393.598,6348.06104,22.840,
5269.58105,394.598,6348.15283,22.840,
5269.67236,393.598,6348.24414,21.840,
5269.76367,394.598,6348.33594,22.840,
5269.85547,393.598,6348.42725,22.840,
5269.94678,393.598,6348.51855,21.840,
5270.03857,393.598,6348.61035,21.840,
5270.12988,393.598,6348.70166,21.840,
5270.22168,392.598,6348.79346,22.840,
5270.31299,392.598,6348.88477,22.840,
5270.40430,393.598,6348.97656,22.840,
5270.49609,392.598,6349.06787,21.840,
5270.58740,392.598,6349.15918,22.840,
5270.67920,392.598,6349.25098,21.840,
5270.77051,392.598,6349.34229,21.840,
5270.86230,391.598,6349.43408,21.840,
5270.95361,392.598,6349.52539,21.840,
5271.04492,392.598,6349.61719,21.840,
5271.13672,392.598,6349.70850,21.840,
5271.22803,391.598,6349.80029,21.840,
5271.31982,392.598,6349.89160,21.840,
5271.41113,391.598,6349.98291,21.840,
5271.50293,391.598,6350.07471,21.840,
5271.59424,391.598,6350.16602,21.840,
5271.68604,391.598,6350.25781,22.840,
5271.77734,391.598,6350.34912,21.840,
5271.86865,391.598,6350.44092,22.840,
5271.96045,391.598,6350.53223,22.840,
5272.05176,390.598,6350.62354,21.840,
5272.14355,391.598,6350.71533,22.840,
5272.23486,390.598,6350.80664,22.840,
5272.32666,390.598,6350.89844,21.840,
5272.41797,390.598,6350.98975,22.840,
5272.50928,391.598,6351.08154,21.840,
5272.60107,390.598,6351.17285,21.840,
5272.69238,390.598,6351.26416,21.840,
5272.78418,390.598,6351.35596,21.840,
5272.87549,390.598,6351.44727,21.840,
5272.96729,390.598,6351.53906,21.840,
5273.05859,389.598,6351.63037,21.840,
5273.14990,389.598,6351.72217,22.840,
5273.24170,389.598,6351.81348,21.840,
5273.33301,389.598,6351.90527,21.840,
5273.42480,389.598,6351.99658,21.840,
5273.51611,389.598,6352.08789,21.840,
5273.60791,389.598,6352.17969,21.840,
5273.69922,389.598,6352.27100,21.840,
5273.79102,388.598,6352.36279,21.840,
5273.88232,388.598,6352.45410,21.840,
5273.97363,389.598,6352.54590,21.840,
5274.06543,388.598,6352.63721,21.840,
5274.15674,388.598,6352.72852,21.840,
5274.24854,388.598,6352.82031,20.840,
5274.33984,388.598,6352.91162,21.840,
5274.43164,388.598,6353.00342,21.840,
5274.52295,387.598,6353.09473,20.840,
5274.61426,387.598,6353.18652,22.840,
5274.70605,387.598,6353.27783,21.840,
5274.79736,387.598,6353.36914,21.840,
5274.88916,387.598,6353.46094,21.840,
5274.98047,388.598,6353.55225,21.840,
5275.07227,387.598,6353.64404,21.840,
5275.16357,387.598,6353.73535,21.840,
5275.25488,387.598,6353.82715,20.840,
5275.34668,387.598,6353.91846,20.840,
5275.43799,388.598,6354.00977,19.840,
5275.52979,387.598,6354.10156,20.840,
5275.62109,387.598,6354.19287,19.840,
5275.71289,387.598,6354.28467,19.840,
5275.80420,387.598,6354.37598,19.840,
5275.89600,387.598,6354.46777,19.840,
5275.98730,386.598,6354.55908,19.840,
5276.07861,386.598,6354.65088,19.840,
5276.17041,386.598,6354.74219,19.840,
5276.26172,386.598,6354.83350,19.840,
5276.35352,386.598,6354.92529,19.840,
5276.44482,386.598,6355.01660,19.840,
5276.53662,386.598,6355.10840,19.840,
5276.62793,385.598,6355.19971,19.840,
5276.71924,386.598,6355.29150,19.840,
5276.81104,386.598,6355.38281,20.840,
5276.90234,386.598,6355.47412,19.840,
5276.99414,385.598,6355.56592,20.840,
5277.08545,385.598,6355.65723,20.840,
5277.17725,385.598,6355.74902,20.840,
5277.26855,385.598,6355.84033,20.840,
5277.35986,385.598,6355.93213,20.840,
5277.45166,385.598,6356.02344,21.840,
5277.54297,384.598,6356.11475,21.840,
5277.63477,385.598,6356.20654,20.840,
5277.72607,384.598,6356.29785,19.840,
5277.81787,384.598,6356.38965,19.840,
5277.90918,384.598,6356.48096,18.840,
5278.00098,384.598,6356.57275,17.840,
5278.09229,383.598,6356.66406,17.840,
5278.18359,384.598,6356.75586,17.840,
5278.27539,384.598,6356.84717,17.840,
5278.36670,384.598,6356.93848,17.840,
5278.45850,383.598,6357.03027,17.840,
5278.54980,384.598,6357.12158,17.840,
5278.64160,383.598,6357.21338,18.840,
5278.73291,383.598,6357.30469,18.840,
5278.82422,383.598,6357.39648,19.840,
5278.91602,383.598,6357.48779,18.840,
5279.00732,383.598,6357.57910,20.840,
5279.09912,383.598,6357.67090,19.840,
5279.19043,383.598,6357.76221,20.840,
5279.28223,382.598,6357.85400,20.840,
5279.37354,382.598,6357.94531,20.840,
5279.46484,382.598,6358.03711,20.840,
5279.55664,382.598,6358.12842,20.840,
5279.64795,382.598,6358.21973,20.840,
5279.73975,382.598,6358.31152,20.840,
5279.83105,382.598,6358.40283,20.840,
5279.92285,382.598,6358.49463,20.840,
5280.01416,381.598,6358.58594,20.840,
5280.10596,382.598,6358.67773,20.840,
5280.19727,381.598,6358.76904,20.840,
5280.28857,381.598,6358.86084,20.840,
5280.38037,381.598,6358.95215,20.840,
5280.47168,381.598,6359.04346,21.840,
5280.56348,381.598,6359.13525,20.840,
5280.65479,381.598,6359.22656,20.840,
5280.74658,381.598,6359.31836,20.840,
5280.83789,381.598,6359.40967,20.840,
5280.92920,381.598,6359.50146,20.840,
5281.02100,381.598,6359.59277,19.840,
5281.11230,381.598,6359.68408,20.840,
5281.20410,380.598,6359.77588,20.840,
5281.29541,381.598,6359.86719,20.840,
5281.38721,380.598,6359.95898,20.840,
5281.47852,380.598,6360.05029,20.840,
5281.56982,380.598,6360.14209,19.840,
5281.66162,380.598,6360.23340,20.840,
5281.75293,380.598,6360.32471,19.840,
5281.84473,379.598,6360.41650,20.840,
5281.93604,379.598,6360.50781,20.840,
5282.02783,379.598,6360.59961,20.840,
5282.11914,379.598,6360.69092,19.840,
5282.21045,379.598,6360.78271,20.840,
5282.30225,379.598,6360.87402,20.840,
5282.39355,379.598,6360.96582,19.840,
5282.48535,379.598,6361.05713,19.840,
5282.57666,379.598,6361.14844,20.840,
5282.66846,379.598,6361.24023,20.840,
5282.75977,379.598,6361.33154,20.840,
5282.85156,379.598,6361.42334,19.840,
5282.94287,379.598,6361.51465,20.840,
5283.03418,378.598,6361.60645,19.840,
5283.12598,378.598,6361.69775,20.840,
5283.21729,378.598,6361.78906,19.840,
5283.30908,378.598,6361.88086,20.840,
5283.40039,378.598,6361.97217,20.840,
5283.49219,378.598,6362.06396,20.840,
5283.58350,378.598,6362.15527,20.840,
5283.67480,378.598,6362.24707,20.840,
5283.76660,377.598,6362.33838,20.840,
5283.85791,378.598,6362.42969,20.840,
5283.94971,378.598,6362.52148,20.840,
5284.04102,378.598,6362.61279,19.840,
5284.13281,379.598,6362.70459,20.840,
5284.22412,380.598,6362.79590,20.840,
5284.31543,379.598,6362.88770,19.840,
5284.40723,379.598,6362.97900,19.840,
5284.49854,379.598,6363.07080,20.840,
5284.59033,378.598,6363.16211,20.840,
5284.68164,378.598,6363.25342,19.840,
5284.77344,378.598,6363.34521,20.840,
5284.86475,377.598,6363.43652,20.840,
5284.95654,377.598,6363.52832,20.840,
5285.04785,376.598,6363.61963,19.840,
5285.13916,376.598,6363.71143,20.840,
5285.23096,376.598,6363.80273,20.840,
5285.32227,376.598,6363.89404,19.840,
5285.41406,376.598,6363.98584,19.840,
5285.50537,375.598,6364.07715,19.840,
5285.59717,376.598,6364.16895,19.840,
5285.68848,376.598,6364.26025,19.840,
5285.77979,375.598,6364.35205,19.840,
5285.87158,375.598,6364.44336,19.840,
5285.96289,375.598,6364.53467,19.840,
5286.05469,375.598,6364.62646,19.840,
5286.14600,375.598,6364.71777,19.840,
5286.23779,375.598,6364.80957,19.840,
5286.32910,375.598,6364.90088,19.840,
5286.42041,375.598,6364.99268,19.840,
5286.51221,375.598,6365.08398,19.840,
5286.60352,374.598,6365.17578,19.840,
5286.69531,375.598,6365.26709,19.840,
5286.78662,374.598,6365.35840,19.840,
5286.87842,374.598,6365.45020,19.840,
5286.96973,374.598,6365.54150,19.840,
5287.06152,374.598,6365.63330,19.840,
5287.15283,375.598,6365.72461,19.840,
5287.24414,374.598,6365.81641,19.840,
5287.33594,374.598,6365.90771,19.840,
5287.42725,374.598,6365.99902,19.840,
5287.51904,374.598,6366.09082,19.840,
5287.61035,373.598,6366.18213,19.840,
5287.70215,373.598,6366.27393,19.840,
5287.79346,373.598,6366.36523,19.840,
5287.88477,373.598,6366.45703,19.840,
5287.97656,373.598,6366.54834,19.840,
5288.06787,373.598,6366.63965,19.840,
5288.15967,373.598,6366.73145,18.840,
5288.25098,373.598,6366.82275,19.840,
5288.34277,373.598,6366.91455,19.840,
5288.43408,372.598,6367.00586,19.840,
5288.52539,373.598,6367.09766,19.840,
5288.61719,373.598,6367.18896,18.840,
5288.70850,372.598,6367.28027,18.840,
5288.80029,373.598,6367.37207,19.840,
5288.89160,372.598,6367.46338,18.840,
5288.98340,372.598,6367.55518,19.840,
5289.07471,372.598,6367.64648,18.840,
5289.16650,372.598,6367.73828,18.840,
5289.25781,372.598,6367.82959,19.840,
5289.34912,371.598,6367.92139,18.840,
5289.44092,371.598,6368.01270,18.840,
5289.53223,372.598,6368.10400,18.840,
5289.62402,372.598,6368.19580,18.840,
5289.71533,371.598,6368.28711,18.840,
5289.80713,371.598,6368.37891,18.840,
5289.89844,371.598,6368.47021,18.840,
5289.98975,372.598,6368.56201,18.840,
5290.08154,371.598,6368.65332,18.840,
5290.17285,371.598,6368.74463,18.840,
5290.26465,370.598,6368.83643,18.840,
5290.35596,370.598,6368.92773,18.840,
5290.44775,371.598,6369.01953,18.840,
5290.53906,370.598,6369.11084,18.840,
5290.63037,371.598,6369.20264,18.840,
5290.72217,370.598,6369.29395,18.840,
5290.81348,370.598,6369.38525,17.840,
5290.90527,369.598,6369.47705,18.840,
5290.99658,370.598,6369.56836,18.840,
5291.08838,370.598,6369.66016,18.840,
5291.17969,369.598,6369.75146,19.840,
5291.27148,369.598,6369.84326,18.840,
5291.36279,369.598,6369.93457,18.840,
5291.45410,369.598,6370.02637,18.840,
5291.54590,370.598,6370.11768,18.840,
5291.63721,369.598,6370.20898,18.840,
5291.72900,369.598,6370.30078,18.840,
5291.82031,369.598,6370.39209,18.840,
5291.91211,369.598,6370.48389,18.840,
5292.00342,369.598,6370.57520,17.840,
5292.09473,369.598,6370.66699,18.840,
5292.18652,369.598,6370.75830,18.840,
5292.27783,369.598,6370.84961,18.840,
5292.36963,369.598,6370.94141,18.840,
5292.46094,368.598,6371.03271,18.840,
5292.55273,368.598,6371.12451,18.840,
5292.64404,368.598,6371.21582,18.840,
5292.73535,368.598,6371.30762,18.840,
5292.82715,369.598,6371.39893,18.840,
5292.91846,368.598,6371.49023,18.840,
5293.01025,368.598,6371.58203,18.840,
5293.10156,368.598,6371.67334,18.840,
5293.19336,368.598,6371.76514,18.840,
5293.28467,368.598,6371.85645,17.840,
5293.37598,367.598,6371.94824,18.840,
5293.46777,367.598,6372.03955,17.840,
5293.55908,367.598,6372.13135,18.840,
5293.65088,367.598,6372.22266,18.840,
5293.74219,367.598,6372.31396,18.840,
5293.83398,367.598,6372.40576,17.840,
5293.92529,367.598,6372.49707,17.840,
5294.01709,366.598,6372.58887,18.840,
5294.10840,366.598,6372.68018,17.840,
5294.19971,367.598,6372.77197,17.840,
5294.29150,367.598,6372.86328,18.840,
5294.38281,367.598,6372.95459,18.840,
5294.47461,367.598,6373.04639,17.840,
5294.56592,367.598,6373.13770,17.840,
5294.65771,366.598,6373.22949,18.840,
5294.74902,366.598,6373.32080,17.840,
5294.84033,366.598,6373.41260,18.840,
5294.93213,366.598,6373.50391,18.840,
5295.02344,365.598,6373.59521,17.840,
5295.11523,366.598,6373.68701,18.840,
5295.20654,366.598,6373.77832,18.840,
5295.29834,365.598,6373.87012,18.840,
5295.38965,365.598,6373.96143,17.840,
5295.48096,365.598,6374.05322,17.840,
5295.57275,365.598,6374.14453,18.840,
5295.66406,365.598,6374.23633,17.840,
5295.75586,365.598,6374.32764,17.840,
5295.84717,365.598,6374.41895,17.840,
5295.93896,365.598,6374.51074,17.840,
5296.03027,365.598,6374.60205,17.840,
5296.12207,364.598,6374.69385,17.840,
5296.21338,364.598,6374.78516,17.840,
5296.30469,364.598,6374.87695,17.840,
5296.39648,364.598,6374.96826,17.840,
5296.48779,364.598,6375.05957,17.840,
5296.57959,363.598,6375.15137,17.840,
5296.67090,364.598,6375.24268,17.840,
5296.76270,363.598,6375.33447,17.840,
5296.85400,363.598,6375.42578,17.840,
5296.94531,363.598,6375.51758,16.840,
5297.03711,363.598,6375.60889,17.840,
5297.12842,363.598,6375.70020,17.840,
5297.22021,363.598,6375.79199,17.840,
5297.31152,363.598,6375.88330,17.840,
5297.40332,363.598,6375.97510,17.840,
5297.49463,363.598,6376.06641,17.840,
5297.58594,363.598,6376.15820,17.840,
5297.67773,363.598,6376.24951,17.840,
5297.76904,362.598,6376.34131,17.840,
5297.86084,363.598,6376.43262,17.840,
5297.95215,363.598,6376.52393,17.840,
5298.04395,363.598,6376.61572,17.840,
5298.13525,362.598,6376.70703,16.840,
5298.22705,362.598,6376.79883,16.840,
5298.31836,362.598,6376.89014,15.840,
5298.40967,362.598,6376.98193,14.840,
5298.50146,362.598,6377.07324,14.840,
5298.59277,361.598,6377.16455,14.840,
5298.68457,362.598,6377.25635,14.840,
5298.77588,361.598,6377.34766,14.840,
5298.86768,362.598,6377.43945,14.840,
5298.95898,361.598,6377.53076,14.840,
5299.05029,361.598,6377.62256,14.840,
5299.14209,361.598,6377.71387,14.840,
5299.23340,361.598,6377.80518,15.840,
5299.32520,360.598,6377.89697,15.840,
5299.41650,361.598,6377.98828,15.840,
5299.50830,360.598,6378.08008,16.840,
5299.59961,360.598,6378.17139,16.840,
5299.69092,360.598,6378.26318,16.840,
5299.78271,360.598,6378.35449,17.840,
5299.87402,360.598,6378.44580,16.840,
5299.96582,360.598,6378.53760,17.840,
5300.05713,360.598,6378.62891,16.840,
5300.14893,359.598,6378.72070,17.840,
5300.24023,360.598,6378.81201,17.840,
5300.33203,360.598,6378.90381,16.840,
5300.42334,360.598,6378.99512,17.840,
5300.51465,360.598,6379.08691,17.840,
5300.60645,359.598,6379.17822,17.840,
5300.69775,360.598,6379.26953,17.840,
5300.78955,359.598,6379.36133,17.840,
5300.88086,359.598,6379.45264,17.840,
5300.97266,359.598,6379.54443,17.840,
5301.06396,359.598,6379.63574,17.840,
5301.15527,359.598,6379.72754,17.840,
5301.24707,359.598,6379.81885,17.840,
5301.33838,358.598,6379.91016,17.840,
5301.43018,358.598,6380.00195,17.840,
5301.52148,359.598,6380.09326,17.840,
5301.61328,359.598,6380.18506,17.840,
5301.70459,358.598,6380.27637,17.840,
5301.79590,359.598,6380.36816,17.840,
5301.88770,359.598,6380.45947,16.840,
5301.97900,359.598,6380.55078,17.840,
5302.07080,359.598,6380.64258,17.840,
5302.16211,359.598,6380.73389,16.840,
5302.25391,358.598,6380.82568,16.840,
5302.34521,359.598,6380.91699,17.840,
5302.43701,359.598,6381.00879,17.840,
5302.52832,358.598,6381.10010,17.840,
5302.61963,358.598,6381.19189,16.840,
5302.71143,358.598,6381.28320,16.840,
5302.80273,357.598,6381.37451,17.840,
5302.89453,357.598,6381.46631,17.840,
5302.98584,357.598,6381.55762,17.840,
5303.07764,357.598,6381.64941,17.840,
5303.16895,357.598,6381.74072,16.840,
5303.26025,357.598,6381.83252,16.840,
5303.35205,357.598,6381.92383,16.840,
5303.44336,356.598,6382.01514,16.840,
5303.53516,356.598,6382.10693,17.840,
5303.62646,356.598,6382.19824,16.840,
5303.71826,356.598,6382.29004,16.840,
5303.80957,356.598,6382.38135,17.840,
5303.90088,356.598,6382.47314,17.840,
5303.99268,356.598,6382.56445,16.840,
5304.08398,356.598,6382.65576,17.840,
5304.17578,356.598,6382.74756,17.840,
5304.26709,357.598,6382.83887,16.840,
5304.35889,356.598,6382.93066,16.840,
5304.45020,355.598,6383.02197,16.840,
5304.54199,356.598,6383.11377,16.840,
5304.63330,355.598,6383.20508,16.840,
5304.72461,356.598,6383.29688,16.840,
5304.81641,355.598,6383.38818,16.840,
5304.90771,356.598,6383.47949,16.840,
5304.99951,355.598,6383.57129,16.840,
5305.09082,355.598,6383.66260,16.840,
5305.18262,355.598,6383.75439,17.840,
5305.27393,355.598,6383.84570,16.840,
5305.36523,355.598,6383.93750,17.840,
5305.45703,355.598,6384.02881,16.840,
5305.54834,354.598,6384.12012,16.840,
5305.64014,354.598,6384.21191,16.840,
5305.73145,354.598,6384.30322,16.840,
5305.82324,354.598,6384.39502,16.840,
5305.91455,354.598,6384.48633,16.840,
5306.00586,354.598,6384.57813,16.840,
5306.09766,354.598,6384.66943,16.840,
5306.18896,355.598,6384.76074,16.840,
5306.28076,354.598,6384.85254,16.840,
5306.37207,354.598,6384.94385,16.840,
5306.46387,354.598,6385.03564,16.840,
5306.55518,353.598,6385.12695,16.840,
5306.64648,354.598,6385.21875,16.840,
5306.73828,353.598,6385.31006,16.840,
5306.82959,353.598,6385.40186,17.840,
5306.92139,353.598,6385.49316,17.840,
5307.01270,353.598,6385.58447,16.840,
5307.10449,353.598,6385.67627,16.840,
5307.19580,353.598,6385.76758,17.840,
5307.28760,352.598,6385.85938,17.840,
5307.37891,353.598,6385.95068,17.840,
5307.47021,352.598,6386.04248,17.840,
5307.56201,352.598,6386.13379,17.840,
5307.65332,353.598,6386.22510,16.840,
5307.74512,352.598,6386.31689,17.840,
5307.83643,352.598,6386.40820,17.840,
5307.92822,352.598,6386.50000,17.840,
5308.01953,353.598,6386.59131,16.840,
5308.11084,352.598,6386.68311,16.840,
5308.20264,352.598,6386.77441,16.840,
5308.29395,352.598,6386.86572,17.840,
5308.38574,352.598,6386.95752,17.840,
5308.47705,351.598,6387.04883,16.840,
5308.56885,352.598,6387.14063,16.840,
5308.66016,351.598,6387.23193,16.840,
5308.75146,351.598,6387.32373,17.840,
5308.84326,351.598,6387.41504,16.840,
5308.93457,351.598,6387.50684,16.840,
5309.02637,351.598,6387.59814,17.840,
5309.11768,352.598,6387.68945,16.840,
5309.20947,351.598,6387.78125,16.840,
5309.30078,351.598,6387.87256,16.840,
5309.39258,351.598,6387.96436,16.840,
5309.48389,351.598,6388.05566,16.840,
5309.57520,350.598,6388.14746,16.840,
5309.66699,350.598,6388.23877,16.840,
5309.75830,351.598,6388.33008,16.840,
5309.85010,350.598,6388.42188,16.840,
5309.94141,350.598,6388.51318,16.840,
5310.03320,349.598,6388.60498,16.840,
5310.12451,350.598,6388.69629,16.840,
5310.21582,350.598,6388.78809,16.840,
5310.30762,349.598,6388.87939,17.840,
5310.39893,349.598,6388.97070,16.840,
5310.49072,349.598,6389.06250,16.840,
5310.58203,349.598,6389.15381,17.840,
5310.67383,349.598,6389.24561,16.840,
5310.76514,349.598,6389.33691,16.840,
5310.85645,349.598,6389.42871,16.840,
5310.94824,349.598,6389.52002,16.840,
5311.03955,348.598,6389.61182,15.840,
5311.13135,348.598,6389.70313,16.840,
5311.22266,348.598,6389.79443,16.840,
5311.31445,349.598,6389.88623,16.840,
5311.40576,349.598,6389.97754,16.840,
5311.49756,348.598,6390.06934,16.840,
5311.58887,348.598,6390.16064,16.840,
5311.68018,348.598,6390.25244,15.840,
5311.77197,348.598,6390.34375,16.840,
5311.86328,347.598,6390.43506,16.840,
5311.95508,348.598,6390.52686,15.840,
5312.04639,349.598,6390.61816,16.840,
5312.13818,348.598,6390.70996,16.840,
5312.22949,347.598,6390.80127,16.840,
5312.32080,347.598,6390.89307,15.840,
5312.41260,348.598,6390.98438,15.840,
5312.50391,347.598,6391.07568,16.840,
5312.59570,347.598,6391.16748,15.840,
5312.68701,347.598,6391.25879,17.840,
5312.77881,347.598,6391.35059,16.840,
5312.87012,347.598,6391.44189,16.840,
5312.96143,346.598,6391.53369,16.840,
5313.05322,346.598,6391.62500,15.840,
5313.14453,347.598,6391.71631,15.840,
5313.23633,346.598,6391.80811,15.840,
5313.32764,346.598,6391.89941,15.840,
5313.41943,346.598,6391.99121,15.840,
5313.51074,347.598,6392.08252,15.840,
5313.60254,346.598,6392.17432,16.840,
5313.69385,346.598,6392.26563,15.840,
5313.78516,346.598,6392.35742,15.840,
5313.87695,346.598,6392.44873,15.840,
5313.96826,345.598,6392.54004,16.840,
5314.06006,346.598,6392.63184,15.840,
5314.15137,345.598,6392.72314,16.840,
5314.24316,345.598,6392.81494,15.840,
5314.33447,345.598,6392.90625,16.840,
5314.42578,345.598,6392.99805,15.840,
5314.51758,345.598,6393.08936,16.840,
5314.60889,345.598,6393.18066,16.840,
5314.70068,345.598,6393.27246,15.840,
5314.79199,345.598,6393.36377,15.840,
5314.88379,345.598,6393.45557,15.840,
5314.97510,345.598,6393.54688,15.840,
5315.06641,345.598,6393.63867,15.840,
5315.15820,345.598,6393.72998,16.840,
5315.24951,345.598,6393.82129,15.840,
5315.34131,345.598,6393.91309,16.840,
5315.43262,345.598,6394.00439,16.840,
5315.52441,344.598,6394.09619,16.840,
5315.61572,344.598,6394.18750,16.840,
5315.70752,344.598,6394.27930,16.840,
5315.79883,344.598,6394.37061,16.840,
5315.89014,344.598,6394.46240,15.840,
5315.98193,344.598,6394.55371,15.840,
5316.07324,343.598,6394.64502,16.840,
5316.16504,344.598,6394.73682,16.840,
5316.25635,343.598,6394.82813,16.840,
5316.34814,343.598,6394.91992,16.840,
5316.43945,344.598,6395.01123,15.840,
5316.53076,343.598,6395.10303,16.840,
5316.62256,343.598,6395.19434,15.840,
5316.71387,343.598,6395.28564,16.840,
5316.80566,343.598,6395.37744,16.840,
5316.89697,343.598,6395.46875,16.840,
5316.98877,343.598,6395.56055,16.840,
5317.08008,342.598,6395.65186,17.840,
5317.17139,343.598,6395.74365,16.840,
5317.26318,342.598,6395.83496,17.840,
5317.35449,342.598,6395.92627,17.840,
5317.44629,342.598,6396.01807,16.840,
5317.53760,341.598,6396.10938,17.840,
5317.62939,341.598,6396.20117,17.840,
5317.72070,341.598,6396.29248,17.840,
5317.81250,341.598,6396.38428,17.840,
5317.90381,341.598,6396.47559,17.840,
5317.99512,342.598,6396.56738,17.840,
5318.08691,342.598,6396.65869,17.840,
5318.17822,341.598,6396.75000,17.840,
5318.27002,341.598,6396.84180,17.840,
5318.36133,341.598,6396.93311,17.840,
5318.45313,341.598,6397.02490,16.840,
5318.54443,341.598,6397.11621,17.840,
5318.63574,341.598,6397.20801,17.840,
5318.72754,341.598,6397.29932,17.840,
5318.81885,341.598,6397.39063,16.840,
5318.91064,341.598,6397.48242,17.840,
5319.00195,341.598,6397.57373,16.840,
5319.09375,341.598,6397.66553,16.840,
5319.18506,340.598,6397.75684,16.840,
5319.27637,340.598,6397.84863,16.840,
5319.36816,341.598,6397.93994,16.840,
5319.45947,340.598,6398.03125,16.840,
5319.55127,340.598,6398.12305,16.840,
5319.64258,341.598,6398.21436,16.840,
5319.73438,340.598,6398.30615,17.840,
5319.82568,341.598,6398.39746,16.840,
5319.91699,341.598,6398.48926,16.840,
5320.00879,341.598,6398.58057,17.840,
5320.10010,341.598,6398.67236,17.840,
5320.19189,341.598,6398.76367,17.840,
5320.28320,341.598,6398.85498,17.840,
5320.37500,340.598,6398.94678,17.840,
5320.46631,340.598,6399.03809,17.840,
5320.55811,340.598,6399.12988,16.840,
5320.64941,340.598,6399.22119,17.840,
5320.74072,340.598,6399.31299,16.840,
5320.83252,340.598,6399.40430,16.840,
5320.92383,339.598,6399.49561,16.840,
5321.01563,339.598,6399.58740,16.840,
5321.10693,339.598,6399.67871,16.840,
5321.19873,339.598,6399.77051,15.840,
5321.29004,338.598,6399.86182,15.840,
5321.38135,339.598,6399.95361,16.840,
5321.47314,338.598,6400.04492,16.840,
5321.56445,338.598,6400.13623,16.840,
5321.65625,338.598,6400.22803,16.840,
5321.74756,338.598,6400.31934,15.840,
5321.83936,338.598,6400.41113,15.840,
5321.93066,337.598,6400.50244,16.840,
5322.02197,337.598,6400.59424,15.840,
5322.11377,337.598,6400.68555,15.840,
5322.20508,337.598,6400.77734,16.840,
5322.29688,338.598,6400.86865,15.840,
5322.38818,337.598,6400.95996,15.840,
5322.47998,336.598,6401.05176,15.840,
5322.57129,337.598,6401.14307,15.840,
5322.66309,337.598,6401.23486,15.840,
5322.75439,337.598,6401.32617,15.840,
5322.84570,337.598,6401.41797,15.840,
5322.93750,337.598,6401.50928,16.840,
5323.02881,336.598,6401.60059,15.840,
5323.12061,337.598,6401.69238,16.840,
5323.21191,336.598,6401.78369,15.840,
5323.30371,336.598,6401.87549,15.840,
5323.39502,335.598,6401.96680,15.840,
5323.48633,336.598,6402.05859,15.840,
5323.57813,336.598,6402.14990,15.840,
5323.66943,336.598,6402.24121,15.840,
5323.76123,335.598,6402.33301,15.840,
5323.85254,336.598,6402.42432,15.840,
5323.94434,336.598,6402.51611,15.840,
5324.03564,335.598,6402.60742,15.840,
5324.12695,335.598,6402.69922,15.840,
5324.21875,335.598,6402.79053,15.840,
5324.31006,335.598,6402.88232,15.840,
5324.40186,335.598,6402.97363,16.840,
5324.49316,335.598,6403.06494,15.840,
5324.58496,335.598,6403.15674,16.840,
5324.67627,334.598,6403.24805,15.840,
5324.76807,334.598,6403.33984,16.840,
5324.85938,334.598,6403.43115,15.840,
5324.95068,334.598,6403.52295,16.840,
5325.04248,334.598,6403.61426,15.840,
5325.13379,334.598,6403.70557,15.840,
5325.22559,334.598,6403.79736,15.840,
5325.31689,334.598,6403.88867,15.840,
5325.40869,334.598,6403.98047,15.840,
5325.50000,334.598,6404.07178,15.840,
5325.59131,334.598,6404.16357,15.840,
5325.68311,334.598,6404.25488,15.840,
5325.77441,333.598,6404.34619,15.840,
5325.86621,334.598,6404.43799,16.840,
5325.95752,334.598,6404.52930,15.840,
5326.04932,333.598,6404.62109,15.840,
5326.14063,333.598,6404.71240,15.840,
5326.23193,333.598,6404.80420,15.840,
5326.32373,333.598,6404.89551,15.840,
5326.41504,333.598,6404.98682,15.840,
5326.50684,333.598,6405.07861,15.840,
5326.59814,333.598,6405.16992,16.840,
5326.68994,333.598,6405.26172,15.840,
5326.78125,333.598,6405.35303,16.840,
5326.87305,333.598,6405.44482,15.840,
5326.96436,333.598,6405.53613,15.840,
5327.05566,332.598,6405.62793,15.840,
5327.14746,333.598,6405.71924,15.840,
5327.23877,333.598,6405.81055,15.840,
5327.33057,332.598,6405.90234,16.840,
5327.42188,332.598,6405.99365,15.840,
5327.51367,332.598,6406.08545,16.840,
5327.60498,332.598,6406.17676,15.840,
5327.69629,332.598,6406.26855,15.840,
5327.78809,332.598,6406.35986,15.840,
5327.87939,332.598,6406.45117,15.840,
5327.97119,331.598,6406.54297,15.840,
5328.06250,332.598,6406.63428,15.840,
5328.15430,332.598,6406.72607,15.840,
5328.24561,331.598,6406.81738,15.840,
5328.33691,331.598,6406.90918,15.840,
5328.42871,331.598,6407.00049,15.840,
5328.52002,331.598,6407.09180,15.840,
5328.61182,331.598,6407.18359,15.840,
5328.70313,331.598,6407.27490,16.840,
5328.79492,331.598,6407.36670,16.840,
5328.88623,331.598,6407.45801,15.840,
5328.97803,331.598,6407.54980,15.840,
5329.06934,331.598,6407.64111,15.840,
5329.16064,330.598,6407.73291,15.840,
5329.25244,330.598,6407.82422,15.840,
5329.34375,330.598,6407.91553,15.840,
5329.43555,330.598,6408.00732,15.840,
5329.52686,330.598,6408.09863,15.840,
5329.61865,330.598,6408.19043,15.840,
5329.70996,330.598,6408.28174,15.840,
5329.80127,330.598,6408.37354,15.840,
5329.89307,329.598,6408.46484,16.840,
5329.98438,330.598,6408.55615,15.840,
5330.07617,329.598,6408.64795,15.840,
5330.16748,330.598,6408.73926,15.840,
5330.25928,330.598,6408.83105,16.840,
5330.35059,329.598,6408.92236,15.840,
5330.44189,329.598,6409.01416,15.840,
5330.53369,329.598,6409.10547,15.840,
5330.62500,329.598,6409.19678,15.840,
5330.71680,329.598,6409.28857,15.840,
5330.80811,329.598,6409.37988,15.840,
5330.89990,329.598,6409.47168,15.840,
5330.99121,328.598,6409.56299,15.840,
5331.08252,330.598,6409.65479,15.840,
5331.17432,329.598,6409.74609,15.840,
5331.26563,328.598,6409.83789,14.840,
5331.35742,329.598,6409.92920,15.840,
5331.44873,328.598,6410.02051,15.840,
5331.54053,329.598,6410.11230,14.840,
5331.63184,329.598,6410.20361,15.840,
5331.72363,329.598,6410.29541,16.840,
5331.81494,328.598,6410.38672,15.840,
5331.90625,328.598,6410.47852,15.840,
5331.99805,328.598,6410.56982,15.840,
5332.08936,328.598,6410.66113,15.840,
5332.18115,327.598,6410.75293,15.840,
5332.27246,327.598,6410.84424,15.840,
5332.36426,327.598,6410.93604,15.840,
5332.45557,327.598,6411.02734,15.840,
5332.54688,328.598,6411.11914,15.840,
5332.63867,327.598,6411.21045,15.840,
5332.72998,327.598,6411.30176,15.840,
5332.82178,327.598,6411.39355,15.840,
5332.91309,327.598,6411.48486,15.840,
5333.00488,327.598,6411.57666,15.840,
5333.09619,327.598,6411.66797,15.840,
5333.18750,326.598,6411.75977,16.840,
5333.27930,327.598,6411.85107,15.840,
5333.37061,326.598,6411.94287,15.840,
5333.46240,326.598,6412.03418,15.840,
5333.55371,326.598,6412.12549,15.840,
5333.64551,326.598,6412.21729,15.840,
5333.73682,326.598,6412.30859,15.840,
5333.82861,326.598,6412.40039,15.840,
5333.91992,326.598,6412.49170,15.840,
5334.01123,326.598,6412.58350,15.840,
5334.10303,326.598,6412.67480,15.840,
5334.19434,326.598,6412.76611,15.840,
5334.28613,326.598,6412.85791,14.840,
5334.37744,326.598,6412.94922,15.840,
5334.46924,326.598,6413.04102,15.840,
5334.56055,326.598,6413.13232,15.840,
5334.65186,325.598,6413.22412,15.840,
5334.74365,326.598,6413.31543,15.840,
5334.83496,325.598,6413.40674,15.840,
5334.92676,325.598,6413.49854,15.840,
5335.01807,325.598,6413.58984,15.840,
5335.10986,325.598,6413.68164,15.840,
5335.20117,325.598,6413.77295,15.840,
5335.29248,325.598,6413.86475,15.840,
5335.38428,324.598,6413.95605,15.840,
5335.47559,325.598,6414.04785,15.840,
5335.56738,324.598,6414.13916,14.840,
5335.65869,324.598,6414.23047,15.840,
5335.75049,324.598,6414.32227,15.840,
5335.84180,324.598,6414.41357,15.840,
5335.93359,324.598,6414.50537,15.840,
5336.02490,324.598,6414.59668,15.840,
5336.11621,324.598,6414.68848,15.840,
5336.20801,324.598,6414.77979,15.840,
5336.29932,324.598,6414.87109,15.840,
5336.39111,323.598,6414.96289,15.840,
5336.48242,323.598,6415.05420,15.840,
5336.57422,323.598,6415.14600,15.840,
5336.66553,323.598,6415.23730,15.840,
5336.75684,323.598,6415.32910,15.840,
5336.84863,323.598,6415.42041,15.840,
5336.93994,324.598,6415.51172,15.840,
5337.03174,323.598,6415.60352,15.840,
5337.12305,322.598,6415.69482,15.840,
5337.21484,323.598,6415.78662,15.840,
5337.30615,322.598,6415.87793,15.840,
5337.39746,322.598,6415.96973,15.840,
5337.48926,322.598,6416.06104,15.840,
5337.58057,322.598,6416.15234,16.840,
5337.67236,322.598,6416.24414,15.840,
5337.76367,322.598,6416.33545,15.840,
5337.85547,322.598,6416.42725,15.840,
5337.94678,322.598,6416.51855,15.840,
5338.03857,322.598,6416.61035,15.840,
5338.12988,323.598,6416.70166,15.840,
5338.22119,323.598,6416.79346,15.840,
5338.31299,323.598,6416.88477,15.840,
5338.40430,323.598,6416.97607,15.840,
5338.49609,323.598,6417.06787,15.840,
5338.58740,322.598,6417.15918,15.840,
5338.67920,322.598,6417.25098,15.840,
5338.77051,322.598,6417.34229,16.840,
5338.86182,321.598,6417.43408,16.840,
5338.95361,321.598,6417.52539,16.840,
5339.04492,321.598,6417.61670,17.840,
5339.13672,321.598,6417.70850,17.840,
5339.22803,320.598,6417.79980,17.840,
5339.31982,320.598,6417.89160,17.840,
5339.41113,320.598,6417.98291,17.840,
5339.50244,320.598,6418.07471,17.840,
5339.59424,320.598,6418.16602,17.840,
5339.68555,320.598,6418.25732,17.840,
5339.77734,320.598,6418.34912,17.840,
5339.86865,320.598,6418.44043,17.840,
5339.96045,320.598,6418.53223,16.840,
5340.05176,320.598,6418.62354,16.840,
5340.14355,320.598,6418.71533,16.840,
5340.23486,320.598,6418.80664,16.840,
5340.32617,319.598,6418.89844,16.840,
5340.41797,320.598,6418.98975,15.840,
5340.50928,319.598,6419.08105,16.840,
5340.60107,319.598,6419.17285,15.840,
5340.69238,319.598,6419.26416,15.840,
5340.78418,319.598,6419.35596,15.840,
5340.87549,319.598,6419.44727,15.840,
5340.96680,318.598,6419.53906,15.840,
5341.05859,318.598,6419.63037,15.840,
5341.14990,318.598,6419.72168,15.840,
5341.24170,318.598,6419.81348,16.840,
5341.33301,319.598,6419.90479,16.840,
5341.42480,317.598,6419.99658,16.840,
5341.51611,318.598,6420.08789,17.840,
5341.60742,318.598,6420.17969,17.840,
5341.69922,318.598,6420.27100,16.840,
5341.79053,318.598,6420.36230,17.840,
5341.88232,317.598,6420.45410,16.840,
5341.97363,318.598,6420.54541,17.840,
5342.06543,318.598,6420.63721,15.840,
5342.15674,318.598,6420.72852,16.840,
5342.24854,317.598,6420.82031,16.840,
5342.33984,317.598,6420.91162,15.840,
5342.43115,317.598,6421.00342,16.840,
5342.52295,317.598,6421.09473,15.840,
5342.61426,317.598,6421.18604,15.840,
5342.70605,317.598,6421.27783,16.840,
5342.79736,318.598,6421.36914,15.840,
5342.88916,317.598,6421.46094,14.840,
5342.98047,317.598,6421.55225,15.840,
5343.07178,317.598,6421.64404,14.840,
5343.16357,316.598,6421.73535,14.840,
5343.25488,316.598,6421.82666,14.840,
5343.34668,317.598,6421.91846,14.840,
5343.43799,317.598,6422.00977,14.840,
5343.52979,316.598,6422.10156,14.840,
5343.62109,317.598,6422.19287,15.840,
5343.71240,316.598,6422.28467,15.840,
5343.80420,316.598,6422.37598,14.840,
5343.89551,316.598,6422.46729,14.840,
5343.98730,316.598,6422.55908,14.840,
5344.07861,316.598,6422.65039,14.840,
5344.17041,316.598,6422.74219,14.840,
5344.26172,316.598,6422.83350,14.840,
5344.35303,316.598,6422.92529,14.840,
5344.44482,315.598,6423.01660,14.840,
5344.53613,315.598,6423.10840,14.840,
5344.62793,316.598,6423.19971,14.840,
5344.71924,315.598,6423.29102,14.840,
5344.81104,315.598,6423.38281,14.840,
5344.90234,315.598,6423.47412,15.840,
5344.99414,316.598,6423.56592,15.840,
5345.08545,314.598,6423.65723,14.840,
5345.17676,315.598,6423.74902,15.840,
5345.26855,315.598,6423.84033,15.840,
5345.35986,314.598,6423.93164,14.840,
5345.45166,314.598,6424.02344,15.840,
5345.54297,314.598,6424.11475,14.840,
5345.63477,314.598,6424.20654,14.840,
5345.72607,314.598,6424.29785,14.840,
5345.81738,314.598,6424.38965,14.840,
5345.90918,314.598,6424.48096,14.840,
5346.00049,314.598,6424.57227,14.840,
5346.09229,314.598,6424.66406,14.840,
5346.18359,314.598,6424.75537,14.840,
5346.27539,314.598,6424.84717,15.840,
5346.36670,314.598,6424.93848,15.840,
5346.45801,314.598,6425.03027,14.840,
5346.54980,314.598,6425.12158,14.840,
5346.64111,313.598,6425.21338,14.840,
5346.73291,313.598,6425.30469,14.840,
5346.82422,313.598,6425.39600,14.840,
5346.91602,313.598,6425.48779,14.840,
5347.00732,313.598,6425.57910,14.840,
5347.09912,313.598,6425.67090,14.840,
5347.19043,313.598,6425.76221,14.840,
5347.28174,312.598,6425.85400,14.840,
5347.37354,313.598,6425.94531,14.840,
5347.46484,313.598,6426.03662,14.840,
5347.55664,312.598,6426.12842,14.840,
5347.64795,313.598,6426.21973,14.840,
5347.73975,312.598,6426.31152,14.840,
5347.83105,312.598,6426.40283,14.840,
5347.92236,312.598,6426.49463,14.840,
5348.01416,312.598,6426.58594,14.840,
5348.10547,311.598,6426.67725,14.840,
5348.19727,312.598,6426.76904,14.840,
5348.28857,311.598,6426.86035,14.840,
5348.38037,312.598,6426.95215,14.840,
5348.47168,311.598,6427.04346,14.840,
5348.56299,311.598,6427.13525,14.840,
5348.65479,311.598,6427.22656,13.840,
5348.74609,311.598,6427.31836,13.840,
5348.83789,311.598,6427.40967,14.840,
5348.92920,311.598,6427.50098,14.840,
5349.02100,311.598,6427.59277,13.840,
5349.11230,310.598,6427.68408,13.840,
5349.20410,310.598,6427.77588,13.840,
5349.29541,310.598,6427.86719,14.840,
5349.38672,310.598,6427.95898,14.840,
5349.47852,310.598,6428.05029,13.840,
5349.56982,310.598,6428.14160,13.840,
5349.66162,310.598,6428.23340,13.840,
5349.75293,310.598,6428.32471,14.840,
5349.84473,309.598,6428.41650,13.840,
5349.93604,309.598,6428.50781,14.840,
5350.02734,310.598,6428.59961,13.840,
5350.11914,310.598,6428.69092,14.840,
5350.21045,310.598,6428.78223,13.840,
5350.30225,309.598,6428.87402,13.840,
5350.39355,309.598,6428.96533,13.840,
5350.48535,310.598,6429.05713,13.840,
5350.57666,309.598,6429.14844,13.840,
5350.66797,309.598,6429.24023,14.840,
5350.75977,309.598,6429.33154,14.840,
5350.85107,309.598,6429.42285,14.840,
5350.94287,309.598,6429.51465,14.840,
5351.03418,309.598,6429.60596,14.840,
5351.12598,309.598,6429.69775,14.840,
5351.21729,309.598,6429.78906,13.840,
5351.30908,309.598,6429.88086,13.840,
5351.40039,308.598,6429.97217,14.840,
5351.49170,308.598,6430.06396,13.840,
5351.58350,309.598,6430.15527,13.840,
5351.67480,309.598,6430.24658,14.840,
5351.76660,308.598,6430.33838,13.840,
5351.85791,308.598,6430.42969,13.840,
5351.94971,309.598,6430.52148,13.840,
5352.04102,308.598,6430.61279,13.840,
5352.13232,308.598,6430.70459,13.840,
5352.22412,308.598,6430.79590,14.840,
5352.31543,308.598,6430.88721,13.840,
5352.40723,307.598,6430.97900,13.840,
5352.49854,307.598,6431.07031,13.840,
5352.59033,308.598,6431.16211,13.840,
5352.68164,307.598,6431.25342,13.840,
5352.77295,307.598,6431.34521,14.840,
5352.86475,307.598,6431.43652,13.840,
5352.95605,307.598,6431.52783,13.840,
5353.04785,308.598,6431.61963,13.840,
5353.13916,307.598,6431.71094,13.840,
5353.23096,307.598,6431.80273,14.840,
5353.32227,307.598,6431.89404,13.840,
5353.41406,307.598,6431.98584,13.840,
5353.50537,307.598,6432.07715,13.840,
5353.59668,306.598,6432.16895,13.840,
5353.68848,306.598,6432.26025,14.840,
5353.77979,306.598,6432.35156,13.840,
5353.87158,306.598,6432.44336,13.840,
5353.96289,306.598,6432.53467,13.840,
5354.05469,306.598,6432.62646,13.840,
5354.14600,306.598,6432.71777,13.840,
5354.23730,305.598,6432.80957,13.840,
5354.32910,306.598,6432.90088,13.840,
5354.42041,306.598,6432.99219,14.840,
5354.51221,306.598,6433.08398,13.840,
5354.60352,306.598,6433.17529,13.840,
5354.69531,306.598,6433.26709,13.840,
5354.78662,305.598,6433.35840,13.840,
5354.87793,306.598,6433.45020,13.840,
5354.96973,306.598,6433.54150,13.840,
5355.06104,305.598,6433.63281,13.840,
5355.15283,305.598,6433.72461,14.840,
5355.24414,305.598,6433.81592,13.840,
5355.33594,305.598,6433.90771,13.840,
5355.42725,305.598,6433.99902,13.840,
5355.51904,305.598,6434.09082,13.840,
5355.61035,305.598,6434.18213,14.840,
5355.70166,305.598,6434.27393,13.840,
5355.79346,304.598,6434.36523,13.840,
5355.88477,304.598,6434.45654,13.840,
5355.97656,305.598,6434.54834,13.840,
5356.06787,304.598,6434.63965,13.840,
5356.15967,304.598,6434.73145,13.840,
5356.25098,304.598,6434.82275,13.840,
5356.34229,303.598,6434.91455,13.840,
5356.43408,303.598,6435.00586,13.840,
5356.52539,304.598,6435.09717,13.840,
5356.61719,303.598,6435.18896,14.840,
5356.70850,303.598,6435.28027,13.840,
5356.80029,303.598,6435.37207,13.840,
5356.89160,302.598,6435.46338,13.840,
5356.98291,302.598,6435.55518,13.840,
5357.07471,302.598,6435.64648,13.840,
5357.16602,302.598,6435.73779,13.840,
5357.25781,302.598,6435.82959,13.840,
5357.34912,302.598,6435.92090,13.840,
5357.44092,303.598,6436.01270,13.840,
5357.53223,302.598,6436.10400,12.840,
5357.62354,302.598,6436.19580,13.840,
5357.71533,303.598,6436.28711,13.840,
5357.80664,303.598,6436.37891,13.840,
5357.89844,303.598,6436.47021,13.840,
5357.98975,303.598,6436.56152,13.840,
5358.08154,302.598,6436.65332,13.840,
5358.17285,302.598,6436.74463,13.840,
5358.26465,301.598,6436.83643,13.840,
5358.35596,302.598,6436.92773,13.840,
5358.44727,302.598,6437.01953,13.840,
5358.53906,302.598,6437.11084,13.840,
5358.63037,302.598,6437.20215,13.840,
5358.72217,301.598,6437.29395,13.840,
5358.81348,301.598,6437.38525,13.840,
5358.90527,302.598,6437.47705,13.840,
5358.99658,301.598,6437.56836,13.840,
5359.08789,301.598,6437.66016,12.840,
5359.17969,301.598,6437.75146,13.840,
5359.27100,301.598,6437.84277,13.840,
5359.36279,301.598,6437.93457,13.840,
5359.45410,300.598,6438.02588,13.840,
5359.54590,301.598,6438.11768,13.840,
5359.63721,300.598,6438.20898,13.840,
5359.72852,300.598,6438.30078,13.840,
5359.82031,300.598,6438.39209,12.840,
5359.91162,300.598,6438.48389,13.840,
5360.00342,299.598,6438.57520,12.840,
5360.09473,299.598,6438.66650,12.840,
5360.18652,300.598,6438.75830,13.840,
5360.27783,299.598,6438.84961,13.840,
5360.36963,300.598,6438.94141,12.840,
5360.46094,299.598,6439.03271,12.840,
5360.55225,299.598,6439.12451,13.840,
5360.64404,300.598,6439.21582,13.840,
5360.73535,299.598,6439.30713,13.840,
5360.82715,299.598,6439.39893,13.840,
5360.91846,299.598,6439.49023,12.840,
5361.01025,299.598,6439.58203,13.840,
5361.10156,299.598,6439.67334,12.840,
5361.19287,299.598,6439.76514,12.840,
5361.28467,298.598,6439.85645,12.840,
5361.37598,299.598,6439.94775,12.840,
5361.46777,299.598,6440.03955,12.840,
5361.55908,298.598,6440.13086,11.840,
5361.65088,298.598,6440.22266,12.840,
5361.74219,298.598,6440.31396,11.840,
5361.83350,299.598,6440.40576,11.840,
5361.92529,298.598,6440.49707,11.840,
5362.01660,299.598,6440.58838,11.840,
5362.10840,298.598,6440.68018,12.840,
5362.19971,298.598,6440.77148,11.840,
5362.29150,298.598,6440.86328,11.840,
5362.38281,298.598,6440.95459,12.840,
5362.47461,298.598,6441.04639,11.840,
5362.56592,297.598,6441.13770,12.840,
5362.65723,298.598,6441.22949,11.840,
5362.74902,297.598,6441.32080,12.840,
5362.84033,297.598,6441.41211,11.840,
5362.93213,297.598,6441.50391,12.840,
5363.02344,297.598,6441.59521,12.840,
5363.11523,297.598,6441.68701,12.840,
5363.20654,297.598,6441.77832,12.840,
5363.29785,297.598,6441.87012,12.840,
5363.38965,297.598,6441.96143,12.840,
5363.48096,296.598,6442.05273,11.840,
5363.57275,296.598,6442.14453,12.840,
5363.66406,296.598,6442.23584,12.840,
5363.75586,297.598,6442.32764,12.840,
5363.84717,297.598,6442.41895,12.840,
5363.93848,296.598,6442.51074,13.840,
5364.03027,295.598,6442.60205,13.840,
5364.12158,296.598,6442.69336,13.840,
5364.21338,295.598,6442.78516,13.840,
5364.30469,296.598,6442.87646,12.840,
5364.39648,296.598,6442.96826,12.840,
5364.48779,296.598,6443.05957,12.840,
5364.57959,295.598,6443.15137,13.840,
5364.67090,295.598,6443.24268,12.840,
5364.76221,296.598,6443.33447,12.840,
5364.85400,295.598,6443.42578,12.840,
5364.94531,295.598,6443.51709,12.840,
5365.03711,295.598,6443.60889,12.840,
5365.12842,295.598,6443.70020,12.840,
5365.22021,295.598,6443.79199,12.840,
5365.31152,295.598,6443.88330,12.840,
5365.40283,295.598,6443.97510,13.840,
5365.49463,295.598,6444.06641,12.840,
5365.58594,295.598,6444.15771,12.840,
5365.67773,295.598,6444.24951,12.840,
5365.76904,295.598,6444.34082,12.840,
5365.86084,294.598,6444.43262,12.840,
5365.95215,294.598,6444.52393,12.840,
5366.04346,294.598,6444.61572,12.840,
5366.13525,294.598,6444.70703,12.840,
5366.22656,294.598,6444.79834,11.840,
5366.31836,294.598,6444.89014,12.840,
5366.40967,294.598,6444.98145,12.840,
5366.50146,293.598,6445.07324,11.840,
5366.59277,294.598,6445.16455,11.840,
5366.68457,293.598,6445.25635,12.840,
5366.77588,293.598,6445.34766,11.840,
5366.86719,293.598,6445.43945,12.840,
5366.95898,294.598,6445.53076,12.840,
5367.05029,293.598,6445.62207,11.840,
5367.14209,293.598,6445.71387,11.840,
5367.23340,293.598,6445.80518,12.840,
5367.32520,293.598,6445.89697,12.840,
5367.41650,293.598,6445.98828,11.840,
5367.50781,292.598,6446.08008,12.840,
5367.59961,293.598,6446.17139,12.840,
5367.69092,293.598,6446.26270,11.840,
5367.78271,293.598,6446.35449,12.840,
5367.87402,292.598,6446.44580,12.840,
5367.96582,292.598,6446.53760,11.840,
5368.05713,292.598,6446.62891,11.840,
5368.14844,293.598,6446.72070,12.840,
5368.24023,292.598,6446.81201,12.840,
5368.33154,292.598,6446.90332,12.840,
5368.42334,292.598,6446.99512,12.840,
5368.51465,292.598,6447.08643,12.840,
5368.60645,292.598,6447.17822,12.840,
5368.69775,292.598,6447.26953,12.840,
5368.78906,292.598,6447.36133,12.840,
5368.88086,291.598,6447.45264,12.840,
5368.97217,291.598,6447.54443,12.840,
5369.06396,292.598,6447.63574,12.840,
5369.15527,292.598,6447.72705,12.840,
5369.24707,291.598,6447.81885,11.840,
5369.33838,291.598,6447.91016,11.840,
5369.43018,291.598,6448.00195,12.840,
5369.52148,291.598,6448.09326,11.840,
5369.61279,291.598,6448.18506,11.840,
5369.70459,291.598,6448.27637,12.840,
5369.79590,290.598,6448.36768,12.840,
5369.88770,291.598,6448.45947,12.840,
5369.97900,290.598,6448.55078,12.840,
5370.07080,290.598,6448.64258,11.840,
5370.16211,290.598,6448.73389,11.840,
5370.25342,290.598,6448.82568,11.840,
5370.34521,290.598,6448.91699,11.840,
5370.43652,290.598,6449.00830,11.840,
5370.52832,289.598,6449.10010,11.840,
5370.61963,290.598,6449.19141,11.840,
5370.71143,290.598,6449.28320,11.840,
5370.80273,290.598,6449.37451,11.840,
5370.89404,290.598,6449.46631,11.840,
5370.98584,289.598,6449.55762,11.840,
5371.07715,289.598,6449.64941,12.840,
5371.16895,289.598,6449.74072,11.840,
5371.26025,289.598,6449.83203,12.840,
5371.35205,289.598,6449.92383,11.840,
5371.44336,289.598,6450.01514,11.840,
5371.53516,289.598,6450.10693,12.840,
5371.62646,288.598,6450.19824,11.840,
5371.71777,289.598,6450.29004,11.840,
5371.80957,289.598,6450.38135,11.840,
5371.90088,289.598,6450.47266,11.840,
5371.99268,288.598,6450.56445,12.840,
5372.08398,289.598,6450.65576,11.840,
5372.17578,289.598,6450.74756,11.840,
5372.26709,288.598,6450.83887,12.840,
5372.35840,288.598,6450.93066,11.840,
5372.45020,288.598,6451.02197,11.840,
5372.54150,288.598,6451.11328,11.840,
5372.63330,288.598,6451.20508,11.840,
5372.72461,288.598,6451.29639,12.840,
5372.81641,288.598,6451.38818,11.840,
5372.90771,288.598,6451.47949,11.840,
5372.99902,287.598,6451.57129,11.840,
5373.09082,287.598,6451.66260,11.840,
5373.18213,287.598,6451.75439,11.840,
5373.27393,287.598,6451.84570,11.840,
5373.36523,287.598,6451.93701,11.840,
5373.45703,287.598,6452.02881,11.840,
5373.54834,288.598,6452.12012,11.840,
5373.64014,287.598,6452.21191,11.840,
5373.73145,287.598,6452.30322,12.840,
5373.82275,287.598,6452.39502,11.840,
5373.91455,287.598,6452.48633,11.840,
5374.00586,287.598,6452.57764,11.840,
5374.09766,287.598,6452.66943,11.840,
5374.18896,286.598,6452.76074,12.840,
5374.28076,286.598,6452.85254,11.840,
5374.37207,286.598,6452.94385,11.840,
5374.46338,286.598,6453.03564,11.840,
5374.55518,286.598,6453.12695,11.840,
5374.64648,287.598,6453.21826,11.840,
5374.73828,286.598,6453.31006,11.840,
5374.82959,286.598,6453.40137,11.840,
5374.92139,286.598,6453.49316,11.840,
5375.01270,287.598,6453.58447,11.840,
5375.10400,286.598,6453.67627,11.840,
5375.19580,286.598,6453.76758,11.840,
5375.28711,286.598,6453.85889,11.840,
5375.37891,286.598,6453.95068,10.840,
5375.47021,286.598,6454.04199,10.840,
5375.56201,286.598,6454.13379,11.840,
5375.65332,285.598,6454.22510,12.840,
5375.74512,286.598,6454.31689,11.840,
5375.83643,285.598,6454.40820,11.840,
5375.92773,285.598,6454.50000,11.840,
5376.01953,285.598,6454.59131,11.840,
5376.11084,285.598,6454.68262,11.840,
5376.20264,284.598,6454.77441,11.840,
5376.29395,285.598,6454.86572,11.840,
5376.38574,285.598,6454.95752,11.840,
5376.47705,285.598,6455.04883,10.840,
5376.56836,284.598,6455.14063,11.840,
5376.66016,284.598,6455.23193,10.840,
5376.75146,283.598,6455.32324,10.840,
5376.84326,282.598,6455.41504,10.840,
5376.93457,282.598,6455.50635,11.840,
5377.02637,282.598,6455.59814,11.840,
5377.11768,282.598,6455.68945,12.840,
5377.20898,282.598,6455.78125,11.840,
5377.30078,282.598,6455.87256,11.840,
5377.39209,282.598,6455.96387,11.840,
5377.48389,282.598,6456.05566,11.840,
5377.57520,283.598,6456.14697,11.840,
5377.66699,283.598,6456.23877,11.840,
5377.75830,283.598,6456.33008,11.840,
5377.85010,282.598,6456.42188,11.840,
5377.94141,283.598,6456.51318,11.840,
5378.03271,282.598,6456.60498,11.840,
5378.12451,282.598,6456.69629,11.840,
5378.21582,283.598,6456.78760,11.840,
5378.30762,283.598,6456.87939,11.840,
5378.39893,282.598,6456.97070,11.840,
5378.49072,282.598,6457.06250,10.840,
5378.58203,282.598,6457.15381,11.840,
5378.67334,282.598,6457.24561,11.840,
5378.76514,282.598,6457.33691,11.840,
5378.85645,282.598,6457.42822,10.840,
5378.94824,282.598,6457.52002,11.840,
5379.03955,282.598,6457.61133,11.840,
5379.13135,282.598,6457.70313,10.840,
5379.22266,281.598,6457.79443,10.840,
5379.31396,281.598,6457.88623,11.840,
5379.40576,282.598,6457.97754,10.840,
5379.49707,281.598,6458.06885,11.840,
5379.58887,281.598,6458.16064,10.840,
5379.68018,281.598,6458.25195,11.840,
5379.77197,281.598,6458.34375,10.840,
5379.86328,281.598,6458.43506,11.840,
5379.95508,281.598,6458.52686,11.840,
5380.04639,281.598,6458.61816,11.840,
5380.13770,281.598,6458.70996,10.840,
5380.22949,280.598,6458.80127,11.840,
5380.32080,281.598,6458.89258,10.840,
5380.41260,281.598,6458.98438,11.840,
5380.50391,280.598,6459.07568,10.840,
5380.59570,280.598,6459.16748,10.840,
5380.68701,280.598,6459.25879,10.840,
5380.77832,280.598,6459.35059,11.840,
5380.87012,281.598,6459.44189,10.840,
5380.96143,280.598,6459.53320,11.840,
5381.05322,280.598,6459.62500,11.840,
5381.14453,280.598,6459.71631,11.840,
5381.23633,280.598,6459.80811,10.840,
5381.32764,280.598,6459.89941,11.840,
5381.41895,279.598,6459.99121,10.840,
5381.51074,279.598,6460.08252,11.840,
5381.60205,279.598,6460.17383,10.840,
5381.69385,279.598,6460.26563,11.840,
5381.78516,279.598,6460.35693,10.840,
5381.87695,279.598,6460.44873,10.840,
5381.96826,279.598,6460.54004,10.840,
5382.05957,279.598,6460.63184,10.840,
5382.15137,279.598,6460.72314,10.840,
5382.24268,279.598,6460.81494,10.840,
5382.33447,279.598,6460.90625,10.840,
5382.42578,278.598,6460.99756,10.840,
5382.51758,279.598,6461.08936,10.840,
5382.60889,279.598,6461.18066,10.840,
5382.70068,278.598,6461.27246,10.840,
5382.79199,279.598,6461.36377,10.840,
5382.88330,278.598,6461.45557,10.840,
5382.97510,278.598,6461.54688,11.840,
5383.06641,278.598,6461.63818,10.840,
5383.15820,278.598,6461.72998,10.840,
5383.24951,278.598,6461.82129,10.840,
5383.34131,278.598,6461.91309,10.840,
5383.43262,278.598,6462.00439,10.840,
5383.52393,278.598,6462.09619,10.840,
5383.61572,277.598,6462.18750,11.840,
5383.70703,277.598,6462.27881,10.840,
5383.79883,278.598,6462.37061,11.840,
5383.89014,277.598,6462.46191,10.840,
5383.98193,277.598,6462.55371,11.840,
5384.07324,277.598,6462.64502,11.840,
5384.16455,277.598,6462.73682,11.840,
5384.25635,278.598,6462.82813,11.840,
5384.34766,277.598,6462.91992,10.840,
5384.43945,277.598,6463.01123,11.840,
5384.53076,277.598,6463.10254,11.840,
5384.62256,277.598,6463.19434,11.840,
5384.71387,277.598,6463.28564,11.840,
5384.80566,276.598,6463.37744,10.840,
5384.89697,276.598,6463.46875,10.840,
5384.98828,276.598,6463.56055,10.840,
5385.08008,276.598,6463.65186,10.840,
5385.17139,276.598,6463.74316,10.840,
5385.26318,277.598,6463.83496,10.840,
5385.35449,277.598,6463.92627,10.840,
5385.44629,276.598,6464.01807,10.840,
5385.53760,276.598,6464.10938,10.840,
5385.62891,276.598,6464.20117,10.840,
5385.72070,276.598,6464.29248,10.840,
5385.81201,276.598,6464.38379,10.840,
5385.90381,275.598,6464.47559,10.840,
5385.99512,275.598,6464.56689,9.840,
5386.08691,275.598,6464.65869,9.840,
5386.17822,275.598,6464.75000,8.840,
5386.26953,275.598,6464.84180,8.840,
5386.36133,275.598,6464.93311,8.840,
5386.45264,275.598,6465.02490,8.840,
5386.54443,275.598,6465.11621,8.840,
5386.63574,275.598,6465.20752,8.840,
5386.72754,276.598,6465.29932,8.840,
5386.81885,275.598,6465.39063,9.840,
5386.91064,275.598,6465.48242,8.840,
5387.00195,275.598,6465.57373,9.840,
5387.09326,275.598,6465.66553,9.840,
5387.18506,274.598,6465.75684,8.840,
5387.27637,274.598,6465.84814,9.840,
5387.36816,274.598,6465.93994,10.840,
5387.45947,275.598,6466.03125,9.840,
5387.55127,274.598,6466.12305,9.840,
5387.64258,274.598,6466.21436,9.840,
5387.73389,274.598,6466.30615,10.840,
5387.82568,274.598,6466.39746,10.840,
5387.91699,274.598,6466.48877,10.840,
5388.00879,274.598,6466.58057,10.840,
5388.10010,274.598,6466.67188,10.840,
5388.19189,274.598,6466.76367,10.840,
5388.28320,273.598,6466.85498,10.840,
5388.37451,273.598,6466.94678,10.840,
5388.46631,273.598,6467.03809,10.840,
5388.55762,273.598,6467.12939,9.840,
5388.64941,273.598,6467.22119,10.840,
5388.74072,273.598,6467.31250,10.840,
5388.83252,273.598,6467.40430,10.840,
5388.92383,273.598,6467.49561,9.840,
5389.01563,272.598,6467.58740,10.840,
5389.10693,273.598,6467.67871,10.840,
5389.19824,272.598,6467.77051,10.840,
5389.29004,273.598,6467.86182,10.840,
5389.38135,272.598,6467.95313,10.840,
5389.47314,272.598,6468.04492,10.840,
5389.56445,272.598,6468.13623,10.840,
5389.65625,273.598,6468.22803,10.840,
5389.74756,272.598,6468.31934,10.840,
5389.83887,272.598,6468.41113,10.840,
5389.93066,272.598,6468.50244,10.840,
5390.02197,272.598,6468.59375,10.840,
5390.11377,272.598,6468.68555,10.840,
5390.20508,272.598,6468.77686,10.840,
5390.29688,272.598,6468.86865,11.840,
5390.38818,272.598,6468.95996,10.840,
5390.47949,272.598,6469.05176,10.840,
5390.57129,271.598,6469.14307,10.840,
5390.66260,271.598,6469.23438,10.840,
5390.75439,271.598,6469.32617,10.840,
5390.84570,271.598,6469.41748,10.840,
5390.93750,270.598,6469.50928,10.840,
5391.02881,271.598,6469.60059,10.840,
5391.12061,271.598,6469.69238,10.840,
5391.21191,270.598,6469.78369,10.840,
5391.30322,270.598,6469.87549,10.840,
5391.39502,270.598,6469.96680,9.840,
5391.48633,270.598,6470.05811,10.840,
5391.57813,270.598,6470.14990,10.840,
5391.66943,270.598,6470.24121,9.840,
5391.76123,270.598,6470.33301,10.840,
5391.85254,269.598,6470.42432,10.840,
5391.94385,269.598,6470.51611,10.840,
5392.03564,270.598,6470.60742,9.840,
5392.12695,269.598,6470.69873,10.840,
5392.21875,269.598,6470.79053,10.840,
5392.31006,269.598,6470.88184,9.840,
5392.40186,269.598,6470.97363,10.840,
5392.49316,269.598,6471.06494,9.840,
5392.58447,270.598,6471.15674,9.840,
5392.67627,269.598,6471.24805,9.840,
5392.76758,269.598,6471.33936,9.840,
5392.85938,269.598,6471.43115,9.840,
5392.95068,269.598,6471.52246,9.840,
5393.04248,269.598,6471.61426,9.840,
5393.13379,269.598,6471.70557,10.840,
5393.22510,269.598,6471.79736,10.840,
5393.31689,269.598,6471.88867,9.840,
5393.40820,269.598,6471.98047,9.840,
5393.50000,268.598,6472.07178,9.840,
5393.59131,269.598,6472.16309,9.840,
5393.68311,268.598,6472.25488,9.840,
5393.77441,268.598,6472.34619,9.840,
5393.86621,268.598,6472.43799,9.840,
5393.95752,268.598,6472.52930,9.840,
5394.04883,268.598,6472.62109,9.840,
5394.14063,268.598,6472.71240,9.840,
5394.23193,268.598,6472.80371,9.840,
5394.32373,268.598,6472.89551,10.840,
5394.41504,268.598,6472.98682,9.840,
5394.50684,267.598,6473.07861,9.840,
5394.59814,268.598,6473.16992,9.840,
5394.68945,268.598,6473.26172,10.840,
5394.78125,268.598,6473.35303,10.840,
5394.87256,267.598,6473.44434,10.840,
5394.96436,268.598,6473.53613,10.840,
5395.05566,268.598,6473.62744,9.840,
5395.14746,268.598,6473.71924,9.840,
5395.23877,267.598,6473.81055,10.840,
5395.33008,268.598,6473.90234,10.840,
5395.42188,267.598,6473.99365,9.840,
5395.51318,268.598,6474.08545,9.840,
5395.60498,267.598,6474.17676,10.840,
5395.69629,267.598,6474.26807,10.840,
5395.78809,267.598,6474.35986,9.840,
5395.87939,267.598,6474.45117,9.840,
5395.97119,266.598,6474.54297,9.840,
5396.06250,267.598,6474.63428,9.840,
5396.15381,266.598,6474.72607,10.840,
5396.24561,266.598,6474.81738,9.840,
5396.33691,266.598,6474.90869,9.840,
5396.42871,266.598,6475.00049,9.840,
5396.52002,266.598,6475.09180,9.840,
5396.61182,266.598,6475.18359,9.840,
5396.70313,265.598,6475.27490,9.840,
5396.79443,266.598,6475.36670,9.840,
5396.88623,265.598,6475.45801,9.840,
5396.97754,266.598,6475.54932,9.840,
5397.06934,265.598,6475.64111,9.840,
5397.16064,265.598,6475.73242,9.840,
5397.25244,265.598,6475.82422,9.840,
5397.34375,264.598,6475.91553,9.840,
5397.43506,264.598,6476.00732,9.840,
5397.52686,264.598,6476.09863,9.840,
5397.61816,264.598,6476.19043,10.840,
5397.70996,264.598,6476.28174,10.840,
5397.80127,264.598,6476.37305,10.840,
5397.89307,264.598,6476.46484,9.840,
5397.98438,264.598,6476.55615,10.840,
5398.07617,264.598,6476.64795,10.840,
5398.16748,264.598,6476.73926,9.840,
5398.25879,264.598,6476.83105,9.840,
5398.35059,264.598,6476.92236,10.840,
5398.44189,265.598,6477.01367,9.840,
5398.53369,263.598,6477.10547,9.840,
5398.62500,264.598,6477.19678,10.840,
5398.71680,263.598,6477.28857,9.840,
5398.80811,263.598,6477.37988,9.840,
5398.89941,264.598,6477.47168,9.840,
5398.99121,263.598,6477.56299,10.840,
5399.08252,264.598,6477.65430,10.840,
5399.17432,263.598,6477.74609,10.840,
5399.26563,263.598,6477.83740,9.840,
5399.35742,263.598,6477.92920,10.840,
5399.44873,263.598,6478.02051,10.840,
5399.54004,263.598,6478.11230,9.840,
5399.63184,264.598,6478.20361,9.840,
5399.72314,263.598,6478.29492,9.840,
5399.81494,263.598,6478.38672,9.840,
5399.90625,264.598,6478.47803,9.840,
5399.99805,263.598,6478.56982,9.840,
5400.08936,263.598,6478.66113,10.840,
5400.18115,263.598,6478.75293,10.840,
5400.27246,263.598,6478.84424,9.840,
5400.36377,262.598,6478.93604,9.840,
5400.45557,262.598,6479.02734,9.840,
5400.54688,262.598,6479.11865,10.840,
5400.63867,262.598,6479.21045,9.840,
5400.72998,262.598,6479.30176,9.840,
5400.82178,262.598,6479.39355,9.840,
5400.91309,262.598,6479.48486,9.840,
5401.00439,261.598,6479.57666,9.840,
5401.09619,262.598,6479.66797,10.840,
5401.18750,262.598,6479.75928,9.840,
5401.27930,262.598,6479.85107,10.840,
5401.37061,262.598,6479.94238,9.840,
5401.46240,262.598,6480.03418,9.840,
5401.55371,262.598,6480.12549,9.840,
5401.64502,261.598,6480.21729,10.840,
5401.73682,261.598,6480.30859,9.840,
5401.82813,261.598,6480.39990,9.840,
5401.91992,261.598,6480.49170,9.840,
5402.01123,261.598,6480.58301,10.840,
5402.10303,261.598,6480.67480,9.840,
5402.19434,260.598,6480.76611,9.840,
5402.28613,261.598,6480.85791,9.840,
5402.37744,261.598,6480.94922,9.840,
5402.46875,261.598,6481.04102,9.840,
5402.56055,260.598,6481.13232,9.840,
5402.65186,260.598,6481.22363,9.840,
5402.74365,261.598,6481.31543,9.840,
5402.83496,261.598,6481.40674,9.840,
5402.92676,260.598,6481.49854,9.840,
5403.01807,260.598,6481.58984,9.840,
5403.10938,260.598,6481.68164,9.840,
5403.20117,260.598,6481.77295,9.840,
5403.29248,259.598,6481.86426,9.840,
5403.38428,260.598,6481.95605,9.840,
5403.47559,259.598,6482.04736,9.840,
5403.56738,259.598,6482.13916,9.840,
5403.65869,259.598,6482.23047,9.840,
5403.75000,259.598,6482.32227,9.840,
5403.84180,259.598,6482.41357,9.840,
5403.93311,259.598,6482.50488,9.840,
5404.02490,259.598,6482.59668,9.840,
5404.11621,258.598,6482.68799,9.840,
5404.20801,259.598,6482.77979,9.840,
5404.29932,259.598,6482.87109,9.840,
5404.39111,258.598,6482.96289,9.840,
5404.48242,258.598,6483.05420,9.840,
5404.57373,259.598,6483.14600,9.840,
5404.66553,258.598,6483.23730,9.840,
5404.75684,258.598,6483.32861,9.840,
5404.84863,259.598,6483.42041,9.840,
5404.93994,258.598,6483.51172,9.840,
5405.03174,258.598,6483.60352,9.840,
5405.12305,258.598,6483.69482,9.840,
5405.21436,257.598,6483.78662,9.840,
5405.30615,257.598,6483.87793,9.840,
5405.39746,257.598,6483.96924,9.840,
5405.48926,257.598,6484.06104,9.840,
5405.58057,257.598,6484.15234,9.840,
5405.67236,257.598,6484.24414,9.840,
5405.76367,258.598,6484.33545,9.840,
5405.85498,257.598,6484.42725,9.840,
5405.94678,257.598,6484.51855,9.840,
5406.03809,257.598,6484.60986,9.840,
5406.12988,257.598,6484.70166,9.840,
5406.22119,257.598,6484.79297,9.840,
5406.31299,257.598,6484.88477,9.840,
5406.40430,257.598,6484.97607,10.840,
5406.49561,257.598,6485.06787,9.840,
5406.58740,256.598,6485.15918,9.840,
5406.67871,256.598,6485.25098,9.840,
5406.77051,256.598,6485.34229,9.840,
5406.86182,256.598,6485.43359,9.840,
5406.95361,256.598,6485.52539,9.840,
5407.04492,256.598,6485.61670,9.840,
5407.13672,256.598,6485.70850,10.840,
5407.22803,257.598,6485.79980,9.840,
5407.31934,256.598,6485.89160,9.840,
5407.41113,255.598,6485.98291,8.840,
5407.50244,256.598,6486.07422,8.840,
5407.59424,255.598,6486.16602,9.840,
5407.68555,255.598,6486.25732,8.840,
5407.77734,255.598,6486.34912,9.840,
5407.86865,255.598,6486.44043,9.840,
5407.95996,255.598,6486.53223,8.840,
5408.05176,255.598,6486.62354,9.840,
5408.14307,255.598,6486.71484,9.840,
5408.23486,255.598,6486.80664,9.840,
5408.32617,255.598,6486.89795,9.840,
5408.41797,255.598,6486.98975,9.840,
5408.50928,255.598,6487.08105,9.840,
5408.60059,255.598,6487.17285,9.840,
5408.69238,255.598,6487.26416,9.840,
5408.78369,255.598,6487.35596,8.840,
5408.87549,255.598,6487.44727,8.840,
5408.96680,254.598,6487.53857,8.840,
5409.05859,254.598,6487.63037,8.840,
5409.14990,254.598,6487.72168,7.840,
5409.24170,254.598,6487.81348,8.840,
5409.33301,255.598,6487.90479,9.840,
5409.42432,254.598,6487.99658,9.840,
5409.51611,254.598,6488.08789,9.840,
5409.60742,253.598,6488.17920,9.840,
5409.69922,254.598,6488.27100,9.840,
5409.79053,254.598,6488.36230,9.840,
5409.88232,253.598,6488.45410,9.840,
5409.97363,253.598,6488.54541,9.840,
5410.06494,253.598,6488.63721,10.840,
5410.15674,254.598,6488.72852,9.840,
5410.24805,253.598,6488.81982,9.840,
5410.33984,253.598,6488.91162,9.840,
5410.43115,253.598,6489.00293,9.840,
5410.52295,253.598,6489.09473,9.840,
5410.61426,253.598,6489.18604,9.840,
5410.70557,253.598,6489.27783,9.840,
5410.79736,253.598,6489.36914,10.840,
5410.88867,252.598,6489.46094,9.840,
5410.98047,252.598,6489.55225,9.840,
5411.07178,252.598,6489.64355,9.840,
5411.16357,252.598,6489.73535,10.840,
5411.25488,252.598,6489.82666,9.840,
5411.34668,252.598,6489.91846,9.840,
5411.43799,252.598,6490.00977,9.840,
5411.52930,252.598,6490.10156,9.840,
5411.62109,253.598,6490.19287,9.840,
5411.71240,252.598,6490.28418,9.840,
5411.80420,252.598,6490.37598,9.840,
5411.89551,252.598,6490.46729,8.840,
5411.98730,251.598,6490.55908,9.840,
5412.07861,252.598,6490.65039,9.840,
5412.16992,251.598,6490.74219,9.840,
5412.26172,251.598,6490.83350,9.840,
5412.35303,251.598,6490.92480,9.840,
5412.44482,251.598,6491.01660,9.840,
5412.53613,251.598,6491.10791,9.840,
5412.62793,251.598,6491.19971,9.840,
5412.71924,251.598,6491.29102,9.840,
5412.81055,251.598,6491.38281,9.840,
5412.90234,250.598,6491.47412,8.840,
5412.99365,251.598,6491.56543,9.840,
5413.08545,251.598,6491.65723,9.840,
5413.17676,251.598,6491.74854,9.840,
5413.26855,251.598,6491.84033,9.840,
5413.35986,251.598,6491.93164,9.840,
5413.45166,250.598,6492.02344,9.840,
5413.54297,250.598,6492.11475,9.840,
5413.63428,250.598,6492.20654,9.840,
5413.72607,251.598,6492.29785,9.840,
5413.81738,250.598,6492.38916,9.840,
5413.90918,250.598,6492.48096,9.840,
5414.00049,250.598,6492.57227,9.840,
5414.09229,250.598,6492.66406,9.840,
5414.18359,249.598,6492.75537,9.840,
5414.27490,249.598,6492.84717,9.840,
5414.36670,249.598,6492.93848,9.840,
5414.45801,249.598,6493.02979,9.840,
5414.54980,250.598,6493.12158,9.840,
5414.64111,249.598,6493.21289,8.840,
5414.73291,249.598,6493.30469,9.840,
5414.82422,249.598,6493.39600,9.840,
5414.91553,249.598,6493.48779,9.840,
5415.00732,249.598,6493.57910,9.840,
5415.09863,249.598,6493.67041,9.840,
5415.19043,249.598,6493.76221,10.840,
5415.28174,249.598,6493.85352,9.840,
5415.37354,249.598,6493.94531,9.840,
5415.46484,249.598,6494.03662,9.840,
5415.55664,249.598,6494.12842,9.840,
5415.64795,249.598,6494.21973,9.840,
5415.73926,248.598,6494.31152,9.840,
5415.83105,248.598,6494.40283,9.840,
5415.92236,249.598,6494.49414,9.840,
5416.01416,249.598,6494.58594,9.840,
5416.10547,248.598,6494.67725,9.840,
5416.19727,248.598,6494.76904,9.840,
5416.28857,248.598,6494.86035,9.840,
5416.37988,248.598,6494.95215,9.840,
5416.47168,248.598,6495.04346,9.840,
5416.56299,248.598,6495.13477,9.840,
5416.65479,247.598,6495.22656,10.840,
5416.74609,247.598,6495.31787,9.840,
5416.83789,247.598,6495.40967,9.840,
5416.92920,247.598,6495.50098,9.840,
5417.02051,247.598,6495.59277,9.840,
5417.11230,247.598,6495.68408,9.840,
5417.20361,247.598,6495.77539,9.840,
5417.29541,247.598,6495.86719,9.840,
5417.38672,247.598,6495.95850,9.840,
5417.47852,247.598,6496.05029,9.840,
5417.56982,247.598,6496.14160,9.840,
5417.66162,247.598,6496.23340,9.840,
5417.75293,247.598,6496.32471,9.840,
5417.84424,247.598,6496.41650,9.840,
5417.93604,247.598,6496.50781,9.840,
5418.02734,247.598,6496.59912,9.840,
5418.11914,246.598,6496.69092,9.840,
5418.21045,246.598,6496.78223,9.840,
5418.30225,245.598,6496.87402,9.840,
5418.39355,245.598,6496.96533,9.840,
5418.48486,244.598,6497.05713,9.840,
5418.57666,244.598,6497.14844,9.840,
5418.66797,245.598,6497.23975,9.840,
5418.75977,245.598,6497.33154,9.840,
5418.85107,244.598,6497.42285,9.840,
5418.94287,245.598,6497.51465,9.840,
5419.03418,245.598,6497.60596,8.840,
5419.12549,245.598,6497.69775,9.840,
5419.21729,245.598,6497.78906,9.840,
5419.30859,246.598,6497.88037,9.840,
5419.40039,245.598,6497.97217,9.840,
5419.49170,246.598,6498.06348,9.840,
5419.58350,245.598,6498.15527,9.840,
5419.67480,245.598,6498.24658,9.840,
5419.76611,245.598,6498.33838,9.840,
5419.85791,245.598,6498.42969,9.840,
5419.94922,245.598,6498.52148,9.840,
5420.04102,245.598,6498.61279,9.840,
5420.13232,245.598,6498.70410,9.840,
5420.22412,245.598,6498.79590,9.840,
5420.31543,244.598,6498.88721,9.840,
5420.40723,245.598,6498.97900,9.840,
5420.49854,245.598,6499.07031,9.840,
5420.58984,244.598,6499.16211,9.840,
5420.68164,245.598,6499.25342,9.840,
5420.77295,245.598,6499.34473,9.840,
5420.86475,244.598,6499.43652,9.840,
5420.95605,244.598,6499.52783,9.840,
5421.04785,244.598,6499.61963,9.840,
5421.13916,245.598,6499.71094,9.840,
5421.23047,244.598,6499.80273,9.840,
5421.32227,244.598,6499.89404,9.840,
5421.41357,244.598,6499.98535,10.840,
5421.50537,243.598,6500.07715,9.840,
5421.59668,244.598,6500.16846,9.840,
5421.68848,243.598,6500.26025,9.840,
5421.77979,244.598,6500.35156,8.840,
5421.87109,244.598,6500.44336,9.840,
5421.96289,244.598,6500.53467,9.840,
5422.05420,244.598,6500.62646,9.840,
5422.14600,243.598,6500.71777,8.840,
5422.23730,243.598,6500.80908,9.840,
5422.32910,243.598,6500.90088,9.840,
5422.42041,243.598,6500.99219,9.840,
5422.51221,243.598,6501.08398,9.840,
5422.60352,243.598,6501.17529,9.840,
5422.69482,243.598,6501.26709,8.840,
5422.78662,242.598,6501.35840,9.840,
5422.87793,243.598,6501.44971,9.840,
5422.96973,243.598,6501.54150,9.840,
5423.06104,242.598,6501.63281,9.840,
5423.15283,243.598,6501.72461,9.840,
5423.24414,242.598,6501.81592,9.840,
5423.33545,243.598,6501.90771,9.840,
5423.42725,242.598,6501.99902,9.840,
5423.51855,242.598,6502.09033,9.840,
5423.61035,242.598,6502.18213,9.840,
5423.70166,242.598,6502.27344,8.840,
5423.79346,242.598,6502.36523,9.840,
5423.88477,242.598,6502.45654,9.840,
5423.97607,242.598,6502.54834,9.840,
5424.06787,242.598,6502.63965,9.840,
5424.15918,242.598,6502.73145,9.840,
5424.25098,241.598,6502.82275,9.840,
5424.34229,242.598,6502.91406,9.840,
5424.43408,242.598,6503.00586,9.840,
5424.52539,241.598,6503.09717,9.840,
5424.61719,241.598,6503.18896,9.840,
5424.70850,241.598,6503.28027,9.840,
5424.79980,242.598,6503.37207,9.840,
5424.89160,241.598,6503.46338,9.840,
5424.98291,241.598,6503.55469,9.840,
5425.07471,241.598,6503.64648,9.840,
5425.16602,241.598,6503.73779,9.840,
5425.25781,241.598,6503.82959,9.840,
5425.34912,241.598,6503.92090,9.840,
5425.44043,241.598,6504.01270,9.840,
5425.53223,240.598,6504.10400,8.840,
5425.62354,240.598,6504.19531,9.840,
5425.71533,240.598,6504.28711,9.840,
5425.80664,240.598,6504.37842,9.840,
5425.89844,239.598,6504.47021,9.840,
5425.98975,240.598,6504.56152,9.840,
5426.08105,240.598,6504.65332,9.840,
5426.17285,240.598,6504.74463,9.840,
5426.26416,241.598,6504.83594,9.840,
5426.35596,240.598,6504.92773,9.840,
5426.44727,240.598,6505.01904,9.840,
5426.53906,240.598,6505.11084,9.840,
5426.63037,240.598,6505.20215,9.840,
5426.72217,239.598,6505.29395,8.840,
5426.81348,239.598,6505.38525,9.840,
5426.90479,240.598,6505.47705,9.840,
5426.99658,239.598,6505.56836,9.840,
5427.08789,239.598,6505.65967,9.840,
5427.17969,239.598,6505.75146,9.840,
5427.27100,239.598,6505.84277,9.840,
5427.36279,239.598,6505.93457,9.840,
5427.45410,239.598,6506.02588,9.840,
5427.54541,239.598,6506.11768,9.840,
5427.63721,238.598,6506.20898,9.840,
5427.72852,240.598,6506.30029,9.840,
5427.82031,239.598,6506.39209,9.840,
5427.91162,238.598,6506.48340,9.840,
5428.00342,238.598,6506.57520,9.840,
5428.09473,239.598,6506.66650,9.840,
5428.18604,238.598,6506.75830,9.840,
5428.27783,238.598,6506.84961,9.840,
5428.36914,239.598,6506.94092,10.840,
5428.46094,239.598,6507.03271,9.840,
5428.55225,238.598,6507.12402,9.840,
5428.64404,238.598,6507.21582,9.840,
5428.73535,238.598,6507.30713,9.840,
5428.82715,238.598,6507.39893,9.840,
5428.91846,238.598,6507.49023,9.840,
5429.00977,238.598,6507.58203,9.840,
5429.10156,238.598,6507.67334,9.840,
5429.19287,238.598,6507.76465,10.840,
5429.28467,238.598,6507.85645,11.840,
5429.37598,238.598,6507.94775,10.840,
5429.46777,237.598,6508.03955,11.840,
5429.55908,237.598,6508.13086,11.840,
5429.65039,238.598,6508.22266,11.840,
5429.74219,237.598,6508.31396,11.840,
5429.83350,237.598,6508.40527,12.840,
5429.92529,237.598,6508.49707,11.840,
5430.01660,237.598,6508.58838,12.840,
5430.10840,236.598,6508.68018,11.840,
5430.19971,236.598,6508.77148,11.840,
5430.29102,236.598,6508.86328,11.840,
5430.38281,236.598,6508.95459,11.840,
5430.47412,236.598,6509.04590,11.840,
5430.56592,237.598,6509.13770,10.840,
5430.65723,237.598,6509.22900,10.840,
5430.74902,236.598,6509.32080,10.840,
5430.84033,236.598,6509.41211,10.840,
5430.93164,236.598,6509.50391,10.840,
5431.02344,236.598,6509.59521,10.840,
5431.11475,236.598,6509.68701,10.840,
5431.20654,236.598,6509.77832,9.840,
5431.29785,236.598,6509.86963,9.840,
5431.38965,236.598,6509.96143,9.840,
5431.48096,236.598,6510.05273,10.840,
5431.57275,236.598,6510.14453,10.840,
5431.66406,235.598,6510.23584,10.840,
5431.75537,235.598,6510.32764,9.840,
5431.84717,235.598,6510.41895,9.840,
5431.93848,235.598,6510.51025,9.840,
5432.03027,235.598,6510.60205,10.840,
5432.12158,236.598,6510.69336,9.840,
5432.21338,235.598,6510.78516,9.840,
5432.30469,235.598,6510.87646,9.840,
5432.39600,235.598,6510.96826,9.840,
5432.48779,235.598,6511.05957,8.840,
5432.57910,235.598,6511.15088,9.840,
5432.67090,235.598,6511.24268,9.840,
5432.76221,235.598,6511.33398,9.840,
5432.85400,234.598,6511.42578,9.840,
5432.94531,234.598,6511.51709,9.840,
5433.03662,234.598,6511.60889,8.840,
5433.12842,234.598,6511.70020,8.840,
5433.21973,234.598,6511.79199,8.840,
5433.31152,234.598,6511.88330,8.840,
5433.40283,234.598,6511.97461,9.840,
5433.49463,233.598,6512.06641,9.840,
5433.58594,234.598,6512.15771,9.840,
5433.67773,234.598,6512.24951,9.840,
5433.76904,234.598,6512.34082,9.840,
5433.86035,234.598,6512.43262,9.840,
5433.95215,234.598,6512.52393,9.840,
5434.04346,233.598,6512.61523,9.840,
5434.13525,233.598,6512.70703,9.840,
5434.22656,233.598,6512.79834,9.840,
5434.31836,233.598,6512.89014,9.840,
5434.40967,233.598,6512.98145,9.840,
5434.50098,233.598,6513.07324,10.840,
5434.59277,233.598,6513.16455,9.840,
5434.68408,233.598,6513.25586,9.840,
5434.77588,233.598,6513.34766,10.840,
5434.86719,233.598,6513.43896,10.840,
5434.95898,232.598,6513.53076,9.840,
5435.05029,233.598,6513.62207,9.840,
5435.14160,232.598,6513.71387,9.840,
5435.23340,232.598,6513.80518,9.840,
5435.32471,232.598,6513.89697,9.840,
5435.41650,232.598,6513.98828,9.840,
5435.50781,233.598,6514.07959,9.840,
5435.59961,232.598,6514.17139,9.840,
5435.69092,232.598,6514.26270,10.840,
5435.78271,232.598,6514.35449,9.840,
5435.87402,232.598,6514.44580,9.840,
5435.96533,232.598,6514.53760,9.840,
5436.05713,232.598,6514.62891,9.840,
5436.14844,232.598,6514.72021,9.840,
5436.24023,232.598,6514.81201,8.840,
5436.33154,232.598,6514.90332,9.840,
5436.42334,232.598,6514.99512,9.840,
5436.51465,232.598,6515.08643,9.840,
5436.60596,232.598,6515.17822,9.840,
5436.69775,231.598,6515.26953,9.840,
5436.78906,231.598,6515.36084,9.840,
5436.88086,231.598,6515.45264,9.840,
5436.97217,231.598,6515.54395,9.840,
5437.06396,232.598,6515.63574,9.840,
5437.15527,231.598,6515.72705,9.840,
5437.24658,231.598,6515.81885,9.840,
5437.33838,231.598,6515.91016,9.840,
5437.42969,231.598,6516.00146,9.840,
5437.52148,231.598,6516.09326,9.840,
5437.61279,231.598,6516.18457,9.840,
5437.70459,231.598,6516.27637,8.840,
5437.79590,231.598,6516.36768,9.840,
5437.88770,231.598,6516.45947,9.840,
5437.97900,231.598,6516.55078,8.840,
5438.07031,231.598,6516.64258,9.840,
5438.16211,231.598,6516.73389,9.840,
5438.25342,231.598,6516.82520,9.840,
5438.34521,230.598,6516.91699,8.840,
5438.43652,230.598,6517.00830,8.840,
5438.52832,230.598,6517.10010,9.840,
5438.61963,230.598,6517.19141,9.840,
5438.71094,230.598,6517.28320,9.840,
5438.80273,229.598,6517.37451,9.840,
5438.89404,229.598,6517.46582,9.840,
5438.98584,229.598,6517.55762,9.840,
5439.07715,229.598,6517.64893,9.840,
5439.16895,230.598,6517.74072,9.840,
5439.26025,229.598,6517.83203,9.840,
5439.35156,229.598,6517.92383,9.840,
5439.44336,230.598,6518.01514,9.840,
5439.53467,229.598,6518.10645,9.840,
5439.62646,229.598,6518.19824,8.840,
5439.71777,229.598,6518.28955,8.840,
5439.80957,229.598,6518.38135,9.840,
5439.90088,228.598,6518.47266,9.840,
5439.99268,229.598,6518.56445,9.840,
5440.08398,229.598,6518.65576,9.840,
5440.17529,228.598,6518.74756,8.840,
5440.26709,228.598,6518.83887,9.840,
5440.35840,228.598,6518.93018,9.840,
5440.45020,227.598,6519.02197,9.840,
5440.54150,227.598,6519.11328,9.840,
5440.63330,227.598,6519.20508,9.840,
5440.72461,227.598,6519.29639,9.840,
5440.81592,227.598,6519.38818,9.840,
5440.90771,228.598,6519.47949,9.840,
5440.99902,228.598,6519.57080,9.840,
5441.09082,227.598,6519.66260,9.840,
5441.18213,228.598,6519.75391,9.840,
5441.27393,228.598,6519.84570,8.840,
5441.36523,227.598,6519.93701,8.840,
5441.45654,228.598,6520.02881,9.840,
5441.54834,228.598,6520.12012,9.840,
5441.63965,228.598,6520.21143,9.840,
5441.73145,227.598,6520.30322,8.840,
5441.82275,228.598,6520.39453,9.840,
5441.91455,227.598,6520.48633,9.840,
5442.00586,227.598,6520.57764,9.840,
5442.09766,227.598,6520.66943,9.840,
5442.18896,227.598,6520.76074,9.840,
5442.28027,227.598,6520.85254,9.840,
5442.37207,227.598,6520.94385,9.840,
5442.46338,227.598,6521.03516,9.840,
5442.55518,227.598,6521.12695,8.840,
5442.64648,227.598,6521.21826,8.840,
5442.73828,227.598,6521.31006,8.840,
5442.82959,227.598,6521.40137,9.840,
5442.92090,226.598,6521.49316,9.840,
5443.01270,227.598,6521.58447,9.840,
5443.10400,227.598,6521.67578,9.840,
5443.19580,226.598,6521.76758,8.840,
5443.28711,226.598,6521.85889,9.840,
5443.37891,226.598,6521.95068,9.840,
5443.47021,226.598,6522.04199,8.840,
5443.56152,226.598,6522.13379,9.840,
5443.65332,226.598,6522.22510,9.840,
5443.74463,226.598,6522.31641,9.840,
5443.83643,226.598,6522.40820,9.840,
5443.92773,225.598,6522.49951,9.840,
5444.01953,226.598,6522.59131,8.840,
5444.11084,226.598,6522.68262,8.840,
5444.20215,226.598,6522.77441,8.840,
5444.29395,226.598,6522.86572,9.840,
5444.38525,226.598,6522.95752,9.840,
5444.47705,226.598,6523.04883,9.840,
5444.56836,225.598,6523.14014,9.840,
5444.66016,225.598,6523.23193,9.840,
5444.75146,225.598,6523.32324,9.840,
5444.84326,225.598,6523.41504,8.840,
5444.93457,225.598,6523.50635,9.840,
5445.02588,225.598,6523.59814,8.840,
5445.11768,225.598,6523.68945,8.840,
5445.20898,225.598,6523.78076,8.840,
5445.30078,225.598,6523.87256,8.840,
5445.39209,224.598,6523.96387,8.840,
5445.48389,225.598,6524.05566,8.840,
5445.57520,225.598,6524.14697,8.840,
5445.66650,225.598,6524.23877,8.840,
5445.75830,224.598,6524.33008,9.840,
5445.84961,224.598,6524.42139,8.840,
5445.94141,224.598,6524.51318,9.840,
5446.03271,224.598,6524.60449,8.840,
5446.12451,224.598,6524.69629,9.840,
5446.21582,224.598,6524.78760,9.840,
5446.30713,224.598,6524.87939,8.840,
5446.39893,224.598,6524.97070,9.840,
5446.49023,224.598,6525.06250,9.840,
5446.58203,224.598,6525.15381,8.840,
5446.67334,223.598,6525.24512,8.840,
5446.76514,224.598,6525.33691,9.840,
5446.85645,224.598,6525.42822,8.840,
5446.94824,223.598,6525.52002,8.840,
5447.03955,224.598,6525.61133,8.840,
5447.13086,223.598,6525.70313,8.840,
5447.22266,224.598,6525.79443,8.840,
5447.31396,224.598,6525.88574,8.840,
5447.40576,223.598,6525.97754,9.840,
5447.49707,223.598,6526.06885,8.840,
5447.58887,223.598,6526.16064,9.840,
5447.68018,223.598,6526.25195,8.840,
5447.77148,223.598,6526.34375,8.840,
5447.86328,222.598,6526.43506,8.840,
5447.95459,222.598,6526.52637,9.840,
5448.04639,223.598,6526.61816,9.840,
5448.13770,223.598,6526.70947,9.840,
5448.22949,223.598,6526.80127,9.840,
5448.32080,223.598,6526.89258,8.840,
5448.41211,222.598,6526.98438,8.840,
5448.50391,223.598,6527.07568,7.840,
5448.59521,222.598,6527.16748,8.840,
5448.68701,223.598,6527.25879,8.840,
5448.77832,222.598,6527.35010,8.840,
5448.87012,222.598,6527.44189,8.840,
5448.96143,222.598,6527.53320,9.840,
5449.05322,222.598,6527.62500,8.840,
5449.14453,222.598,6527.71631,8.840,
5449.23584,222.598,6527.80811,9.840,
5449.32764,222.598,6527.89941,8.840,
5449.41895,221.598,6527.99072,8.840,
5449.51074,221.598,6528.08252,8.840,
5449.60205,222.598,6528.17383,8.840,
5449.69385,222.598,6528.26563,8.840,
5449.78516,222.598,6528.35693,9.840,
5449.87646,221.598,6528.44873,9.840,
5449.96826,221.598,6528.54004,9.840,
5450.05957,222.598,6528.63135,8.840,
5450.15137,221.598,6528.72314,9.840,
5450.24268,221.598,6528.81445,8.840,
5450.33447,221.598,6528.90625,9.840,
5450.42578,221.598,6528.99756,9.840,
5450.51709,221.598,6529.08936,9.840,
5450.60889,221.598,6529.18066,9.840,
5450.70020,220.598,6529.27197,8.840,
5450.79199,221.598,6529.36377,9.840,
5450.88330,220.598,6529.45508,8.840,
5450.97510,220.598,6529.54688,8.840,
5451.06641,220.598,6529.63818,8.840,
5451.15820,221.598,6529.72998,8.840,
5451.24951,220.598,6529.82129,8.840,
5451.34082,220.598,6529.91309,8.840,
5451.43262,220.598,6530.00439,8.840,
5451.52393,220.598,6530.09570,8.840,
5451.61572,220.598,6530.18750,8.840,
5451.70703,220.598,6530.27881,8.840,
5451.79883,220.598,6530.37061,9.840,
5451.89014,219.598,6530.46191,8.840,
5451.98145,219.598,6530.55371,9.840,
5452.07324,219.598,6530.64502,9.840,
5452.16455,219.598,6530.73633,9.840,
5452.25635,219.598,6530.82813,9.840,
5452.34766,219.598,6530.91943,9.840,
5452.43945,219.598,6531.01123,10.840,
5452.53076,219.598,6531.10254,9.840,
5452.62207,220.598,6531.19434,10.840,
5452.71387,219.598,6531.28564,10.840,
5452.80518,219.598,6531.37695,9.840,
5452.89697,219.598,6531.46875,9.840,
5452.98828,219.598,6531.56006,9.840,
5453.08008,218.598,6531.65186,9.840,
5453.17139,218.598,6531.74316,9.840,
5453.26318,219.598,6531.83496,9.840,
5453.35449,218.598,6531.92627,9.840,
5453.44580,218.598,6532.01807,9.840,
5453.53760,219.598,6532.10938,9.840,
5453.62891,218.598,6532.20068,9.840,
5453.72070,218.598,6532.29248,8.840,
5453.81201,218.598,6532.38379,9.840,
5453.90381,218.598,6532.47559,9.840,
5453.99512,218.598,6532.56689,8.840,
5454.08643,218.598,6532.65869,8.840,
5454.17822,218.598,6532.75000,8.840,
5454.26953,217.598,6532.84131,7.840,
5454.36133,217.598,6532.93311,7.840,
5454.45264,218.598,6533.02441,7.840,
5454.54443,218.598,6533.11621,7.840,
5454.63574,217.598,6533.20752,7.840,
5454.72705,217.598,6533.29932,7.840,
5454.81885,217.598,6533.39063,7.840,
5454.91016,217.598,6533.48193,7.840,
5455.00195,217.598,6533.57373,6.840,
5455.09326,217.598,6533.66504,7.840,
5455.18506,217.598,6533.75684,7.840,
5455.27637,217.598,6533.84814,6.840,
5455.36816,217.598,6533.93994,7.840,
5455.45947,216.598,6534.03125,6.840,
5455.55078,217.598,6534.12305,7.840,
5455.64258,217.598,6534.21436,7.840,
5455.73389,216.598,6534.30566,7.840,
5455.82568,216.598,6534.39746,7.840,
5455.91699,216.598,6534.48877,7.840,
5456.00879,216.598,6534.58057,8.840,
5456.10010,216.598,6534.67188,7.840,
5456.19141,216.598,6534.76367,8.840,
5456.28320,216.598,6534.85498,8.840,
5456.37451,216.598,6534.94629,8.840,
5456.46631,215.598,6535.03809,7.840,
5456.55762,216.598,6535.12939,8.840,
5456.64941,216.598,6535.22119,8.840,
5456.74072,216.598,6535.31250,8.840,
5456.83203,216.598,6535.40430,8.840,
5456.92383,216.598,6535.49561,8.840,
5457.01514,216.598,6535.58691,7.840,
5457.10693,215.598,6535.67871,8.840,
5457.19824,215.598,6535.77002,7.840,
5457.29004,215.598,6535.86182,8.840,
5457.38135,215.598,6535.95313,8.840,
5457.47266,215.598,6536.04492,8.840,
5457.56445,215.598,6536.13623,8.840,
5457.65576,215.598,6536.22803,8.840,
5457.74756,215.598,6536.31934,8.840,
5457.83887,214.598,6536.41064,8.840,
5457.93066,214.598,6536.50244,7.840,
5458.02197,214.598,6536.59375,8.840,
5458.11377,215.598,6536.68555,8.840,
5458.20508,214.598,6536.77686,7.840,
5458.29639,214.598,6536.86865,8.840,
5458.38818,214.598,6536.95996,8.840,
5458.47949,215.598,6537.05127,8.840,
5458.57129,214.598,6537.14307,7.840,
5458.66260,214.598,6537.23438,8.840,
5458.75439,214.598,6537.32617,7.840,
5458.84570,214.598,6537.41748,8.840,
5458.93701,214.598,6537.50928,7.840,
5459.02881,214.598,6537.60059,8.840,
5459.12012,214.598,6537.69189,8.840,
5459.21191,214.598,6537.78369,7.840,
5459.30322,213.598,6537.87500,8.840,
5459.39502,213.598,6537.96680,7.840,
5459.48633,214.598,6538.05811,7.840,
5459.57764,213.598,6538.14990,8.840,
5459.66943,213.598,6538.24121,8.840,
5459.76074,213.598,6538.33301,7.840,
5459.85254,213.598,6538.42432,8.840,
5459.94385,213.598,6538.51563,8.840,
5460.03564,213.598,6538.60742,7.840,
5460.12695,213.598,6538.69873,7.840,
5460.21875,213.598,6538.79053,7.840,
5460.31006,213.598,6538.88184,7.840,
5460.40137,212.598,6538.97363,7.840,
5460.49316,213.598,6539.06494,7.840,
5460.58447,213.598,6539.15625,8.840,
5460.67627,212.598,6539.24805,7.840,
5460.76758,213.598,6539.33936,7.840,
5460.85938,213.598,6539.43115,8.840,
5460.95068,212.598,6539.52246,7.840,
5461.04199,212.598,6539.61426,7.840,
5461.13379,212.598,6539.70557,8.840,
5461.22510,212.598,6539.79688,7.840,
5461.31689,212.598,6539.88867,6.840,
5461.40820,212.598,6539.97998,7.840,
5461.50000,212.598,6540.07178,7.840,
5461.59131,212.598,6540.16309,7.840,
5461.68262,212.598,6540.25488,7.840,
5461.77441,211.598,6540.34619,7.840,
5461.86572,211.598,6540.43750,7.840,
5461.95752,211.598,6540.52930,7.840,
5462.04883,211.598,6540.62061,8.840,
5462.14063,211.598,6540.71240,7.840,
5462.23193,211.598,6540.80371,8.840,
5462.32373,210.598,6540.89551,7.840,
5462.41504,210.598,6540.98682,7.840,
5462.50635,211.598,6541.07861,7.840,
5462.59814,211.598,6541.16992,7.840,
5462.68945,210.598,6541.26123,8.840,
5462.78125,209.598,6541.35303,7.840,
5462.87256,210.598,6541.44434,7.840,
5462.96436,209.598,6541.53613,7.840,
5463.05566,209.598,6541.62744,7.840,
5463.14697,209.598,6541.71924,7.840,
5463.23877,209.598,6541.81055,6.840,
5463.33008,209.598,6541.90186,7.840,
5463.42188,209.598,6541.99365,7.840,
5463.51318,209.598,6542.08496,7.840,
5463.60498,210.598,6542.17676,7.840,
5463.69629,209.598,6542.26807,8.840,
5463.78760,209.598,6542.35986,7.840,
5463.87939,209.598,6542.45117,7.840,
5463.97070,210.598,6542.54248,8.840,
5464.06250,209.598,6542.63428,7.840,
5464.15381,209.598,6542.72559,8.840,
5464.24561,209.598,6542.81738,8.840,
5464.33691,210.598,6542.90869,7.840,
5464.42871,209.598,6543.00049,7.840,
5464.52002,209.598,6543.09180,7.840,
5464.61133,209.598,6543.18359,7.840,
5464.70313,209.598,6543.27490,7.840,
5464.79443,209.598,6543.36621,7.840,
5464.88623,208.598,6543.45801,7.840,
5464.97754,209.598,6543.54932,7.840,
5465.06934,208.598,6543.64111,6.840,
5465.16064,209.598,6543.73242,8.840,
5465.25195,208.598,6543.82422,7.840,
5465.34375,208.598,6543.91553,7.840,
5465.43506,208.598,6544.00684,7.840,
5465.52686,208.598,6544.09863,7.840,
5465.61816,208.598,6544.18994,7.840,
5465.70996,208.598,6544.28174,7.840,
5465.80127,208.598,6544.37305,7.840,
5465.89258,208.598,6544.46484,7.840,
5465.98438,208.598,6544.55615,7.840,
5466.07568,208.598,6544.64746,7.840,
5466.16748,207.598,6544.73926,7.840,
5466.25879,207.598,6544.83057,7.840,
5466.35059,207.598,6544.92236,7.840,
5466.44189,208.598,6545.01367,8.840,
5466.53369,207.598,6545.10547,7.840,
5466.62500,207.598,6545.19678,7.840,
5466.71631,207.598,6545.28857,7.840,
5466.80811,207.598,6545.37988,7.840,
5466.89941,207.598,6545.47119,7.840,
5466.99121,207.598,6545.56299,7.840,
5467.08252,206.598,6545.65430,7.840,
5467.17432,207.598,6545.74609,6.840,
5467.26563,207.598,6545.83740,7.840,
5467.35693,207.598,6545.92920,7.840,
5467.44873,206.598,6546.02051,7.840,
5467.54004,206.598,6546.11182,7.840,
5467.63184,207.598,6546.20361,7.840,
5467.72314,206.598,6546.29492,7.840,
5467.81494,207.598,6546.38672,7.840,
5467.90625,207.598,6546.47803,7.840,
5467.99756,206.598,6546.56982,7.840,
5468.08936,206.598,6546.66113,7.840,
5468.18066,206.598,6546.75244,6.840,
5468.27246,206.598,6546.84424,7.840,
5468.36377,205.598,6546.93555,7.840,
5468.45557,206.598,6547.02734,7.840,
5468.54688,206.598,6547.11865,6.840,
5468.63818,205.598,6547.21045,7.840,
5468.72998,206.598,6547.30176,7.840,
5468.82129,205.598,6547.39355,7.840,
5468.91309,205.598,6547.48486,6.840,
5469.00439,205.598,6547.57617,7.840,
5469.09619,206.598,6547.66797,7.840,
5469.18750,205.598,6547.75928,7.840,
5469.27930,205.598,6547.85107,7.840,
5469.37061,205.598,6547.94238,7.840,
5469.46191,205.598,6548.03418,7.840,
5469.55371,204.598,6548.12549,7.840,
5469.64502,205.598,6548.21680,7.840,
5469.73682,205.598,6548.30859,7.840,
5469.82813,204.598,6548.39990,7.840,
5469.91992,204.598,6548.49170,7.840,
5470.01123,204.598,6548.58301,7.840,
5470.10254,205.598,6548.67480,7.840,
5470.19434,205.598,6548.76611,6.840,
5470.28564,204.598,6548.85742,6.840,
5470.37744,204.598,6548.94922,7.840,
5470.46875,204.598,6549.04053,7.840,
5470.56055,204.598,6549.13232,7.840,
5470.65186,204.598,6549.22363,7.840,
5470.74316,204.598,6549.31543,7.840,
5470.83496,204.598,6549.40674,7.840,
5470.92627,204.598,6549.49854,7.840,
5471.01807,204.598,6549.58984,7.840,
5471.10938,203.598,6549.68115,7.840,
5471.20117,204.598,6549.77295,7.840,
5471.29248,204.598,6549.86426,7.840,
5471.38428,203.598,6549.95605,7.840,
5471.47559,203.598,6550.04736,7.840,
5471.56689,203.598,6550.13916,7.840,
5471.65869,203.598,6550.23047,7.840,
5471.75000,203.598,6550.32178,7.840,
5471.84180,203.598,6550.41357,7.840,
5471.93311,202.598,6550.50488,7.840,
5472.02490,202.598,6550.59668,7.840,
5472.11621,203.598,6550.68799,6.840,
5472.20752,202.598,6550.77979,7.840,
5472.29932,203.598,6550.87109,7.840,
5472.39063,201.598,6550.96240,7.840,
5472.48242,202.598,6551.05420,7.840,
5472.57373,202.598,6551.14551,6.840,
5472.66553,202.598,6551.23730,5.840,
5472.75684,202.598,6551.32861,5.840,
5472.84814,202.598,6551.42041,5.840,
5472.93994,202.598,6551.51172,5.840,
5473.03125,202.598,6551.60352,5.840,
5473.12305,202.598,6551.69482,5.840,
5473.21436,202.598,6551.78613,5.840,
5473.30615,202.598,6551.87793,4.840,
5473.39746,202.598,6551.96924,5.840,
5473.48926,201.598,6552.06104,5.840,
5473.58057,201.598,6552.15234,5.840,
5473.67188,202.598,6552.24414,5.840,
5473.76367,201.598,6552.33545,6.840,
5473.85498,201.598,6552.42676,6.840,
5473.94678,201.598,6552.51855,6.840,
5474.03809,201.598,6552.60986,6.840,
5474.12988,201.598,6552.70166,6.840,
5474.22119,200.598,6552.79297,6.840,
5474.31250,201.598,6552.88477,7.840,
5474.40430,200.598,6552.97607,7.840,
5474.49561,200.598,6553.06738,7.840,
5474.58740,202.598,6553.15918,7.840,
5474.67871,201.598,6553.25049,7.840,
5474.77051,200.598,6553.34229,7.840,
5474.86182,200.598,6553.43359,6.840,
5474.95313,201.598,6553.52539,7.840,
5475.04492,200.598,6553.61670,7.840,
5475.13623,200.598,6553.70801,6.840,
5475.22803,200.598,6553.79980,6.840,
5475.31934,200.598,6553.89111,7.840,
5475.41113,200.598,6553.98291,6.840,
5475.50244,199.598,6554.07422,7.840,
5475.59424,200.598,6554.16602,7.840,
5475.68555,199.598,6554.25732,7.840,
5475.77686,199.598,6554.34912,7.840,
5475.86865,200.598,6554.44043,7.840,
5475.95996,200.598,6554.53174,7.840,
5476.05176,200.598,6554.62354,7.840,
5476.14307,200.598,6554.71484,7.840,
5476.23486,199.598,6554.80664,7.840,
5476.32617,199.598,6554.89795,7.840,
5476.41748,199.598,6554.98975,7.840,
5476.50928,200.598,6555.08105,7.840,
5476.60059,198.598,6555.17236,7.840,
5476.69238,199.598,6555.26416,7.840,
5476.78369,199.598,6555.35547,7.840,
5476.87549,199.598,6555.44727,7.840,
5476.96680,199.598,6555.53857,6.840,
5477.05811,199.598,6555.63037,7.840,
5477.14990,198.598,6555.72168,7.840,
5477.24121,199.598,6555.81299,6.840,
5477.33301,198.598,6555.90479,7.840,
5477.42432,199.598,6555.99609,7.840,
5477.51611,199.598,6556.08789,7.840,
5477.60742,198.598,6556.17920,6.840,
5477.69922,198.598,6556.27100,6.840,
5477.79053,198.598,6556.36230,6.840,
5477.88184,198.598,6556.45410,6.840,
5477.97363,199.598,6556.54541,6.840,
5478.06494,198.598,6556.63672,6.840,
5478.15674,198.598,6556.72852,7.840,
5478.24805,198.598,6556.81982,6.840,
5478.33984,198.598,6556.91162,6.840,
5478.43115,198.598,6557.00293,6.840,
5478.52246,198.598,6557.09473,6.840,
5478.61426,198.598,6557.18604,6.840,
5478.70557,197.598,6557.27734,7.840,
5478.79736,197.598,6557.36914,6.840,
5478.88867,197.598,6557.46045,6.840,
5478.98047,198.598,6557.55225,6.840,
5479.07178,197.598,6557.64355,6.840,
5479.16309,197.598,6557.73535,6.840,
5479.25488,197.598,6557.82666,6.840,
5479.34619,197.598,6557.91797,6.840,
5479.43799,196.598,6558.00977,7.840,
5479.52930,197.598,6558.10107,6.840,
5479.62109,196.598,6558.19287,7.840,
5479.71240,196.598,6558.28418,6.840,
5479.80420,196.598,6558.37598,7.840,
5479.89551,196.598,6558.46729,6.840,
5479.98682,195.598,6558.55908,7.840,
5480.07861,196.598,6558.65039,6.840,
5480.16992,196.598,6558.74170,6.840,
5480.26172,196.598,6558.83350,6.840,
5480.35303,196.598,6558.92480,6.840,
5480.44482,197.598,6559.01660,6.840,
5480.53613,195.598,6559.10791,7.840,
5480.62744,195.598,6559.19971,6.840,
5480.71924,195.598,6559.29102,7.840,
5480.81055,196.598,6559.38232,6.840,
5480.90234,195.598,6559.47412,6.840,
5480.99365,195.598,6559.56543,6.840,
5481.08545,196.598,6559.65723,7.840,
5481.17676,195.598,6559.74854,6.840,
5481.26807,195.598,6559.84033,6.840,
5481.35986,195.598,6559.93164,6.840,
5481.45117,194.598,6560.02295,6.840,
5481.54297,195.598,6560.11475,6.840,
5481.63428,194.598,6560.20605,6.840,
5481.72607,195.598,6560.29785,6.840,
5481.81738,194.598,6560.38916,6.840,
5481.90869,195.598,6560.48096,6.840,
5482.00049,195.598,6560.57227,7.840,
5482.09180,194.598,6560.66406,6.840,
5482.18359,194.598,6560.75537,6.840,
5482.27490,194.598,6560.84668,6.840,
5482.36670,194.598,6560.93848,6.840,
5482.45801,194.598,6561.02979,6.840,
5482.54980,194.598,6561.12158,7.840,
5482.64111,194.598,6561.21289,6.840,
5482.73242,193.598,6561.30469,6.840,
5482.82422,194.598,6561.39600,6.840,
5482.91553,193.598,6561.48730,7.840,
5483.00732,193.598,6561.57910,6.840,
5483.09863,193.598,6561.67041,6.840,
5483.19043,193.598,6561.76221,6.840,
5483.28174,193.598,6561.85352,6.840,
5483.37305,193.598,6561.94531,6.840,
5483.46484,193.598,6562.03662,6.840,
5483.55615,193.598,6562.12793,6.840,
5483.64795,193.598,6562.21973,6.840,
5483.73926,193.598,6562.31104,6.840,
5483.83105,193.598,6562.40283,6.840,
5483.92236,193.598,6562.49414,6.840,
5484.01367,193.598,6562.58594,6.840,
5484.10547,193.598,6562.67725,6.840,
5484.19678,193.598,6562.76904,6.840,
5484.28857,193.598,6562.86035,6.840,
5484.37988,193.598,6562.95166,6.840,
5484.47168,193.598,6563.04346,6.840,
5484.56299,193.598,6563.13477,6.840,
5484.65479,193.598,6563.22656,6.840,
5484.74609,192.598,6563.31787,6.840,
5484.83740,193.598,6563.40967,6.840,
5484.92920,192.598,6563.50098,6.840,
5485.02051,192.598,6563.59229,6.840,
5485.11230,192.598,6563.68408,6.840,
5485.20361,192.598,6563.77539,6.840,
5485.29541,192.598,6563.86719,6.840,
5485.38672,191.598,6563.95850,7.840,
5485.47803,191.598,6564.05029,7.840,
5485.56982,191.598,6564.14160,6.840,
5485.66113,190.598,6564.23291,6.840,
5485.75293,191.598,6564.32471,6.840,
5485.84424,190.598,6564.41602,6.840,
5485.93604,191.598,6564.50781,6.840,
5486.02734,190.598,6564.59912,6.840,
5486.11865,190.598,6564.69092,6.840,
5486.21045,191.598,6564.78223,5.840,
5486.30176,190.598,6564.87402,6.840,
5486.39355,190.598,6564.96533,6.840,
5486.48486,191.598,6565.05664,6.840,
5486.57666,190.598,6565.14844,6.840,
5486.66797,191.598,6565.23975,6.840,
5486.75977,191.598,6565.33154,6.840,
5486.85107,190.598,6565.42285,6.840,
5486.94238,190.598,6565.51465,6.840,
5487.03418,190.598,6565.60596,6.840,
5487.12549,190.598,6565.69727,6.840,
5487.21729,190.598,6565.78906,6.840,
5487.30859,190.598,6565.88037,6.840,
5487.40039,190.598,6565.97217,6.840,
5487.49170,190.598,6566.06348,6.840,
5487.58301,190.598,6566.15527,6.840,
5487.67480,190.598,6566.24658,5.840,
5487.76611,191.598,6566.33789,6.840,
5487.85791,190.598,6566.42969,6.840,
5487.94922,189.598,6566.52100,6.840,
5488.04102,190.598,6566.61279,5.840,
5488.13232,190.598,6566.70410,6.840,
5488.22363,189.598,6566.79590,6.840,
5488.31543,190.598,6566.88721,6.840,
5488.40674,189.598,6566.97852,6.840,
5488.49854,190.598,6567.07031,6.840,
5488.58984,189.598,6567.16162,6.840,
5488.68164,189.598,6567.25342,6.840,
5488.77295,189.598,6567.34473,6.840,
5488.86475,189.598,6567.43652,6.840,
5488.95605,189.598,6567.52783,6.840,
5489.04736,189.598,6567.61963,5.840,
5489.13916,188.598,6567.71094,6.840,
5489.23047,189.598,6567.80225,5.840,
5489.32227,189.598,6567.89404,5.840,
5489.41357,188.598,6567.98535,5.840,
5489.50537,189.598,6568.07715,5.840,
5489.59668,189.598,6568.16846,5.840,
5489.68799,188.598,6568.26025,6.840,
5489.77979,189.598,6568.35156,5.840,
5489.87109,189.598,6568.44287,5.840,
5489.96289,188.598,6568.53467,5.840,
5490.05420,187.598,6568.62598,5.840,
5490.14600,188.598,6568.71777,5.840,
5490.23730,188.598,6568.80908,5.840,
5490.32861,188.598,6568.90088,5.840,
5490.42041,187.598,6568.99219,5.840,
5490.51172,187.598,6569.08350,5.840,
5490.60352,188.598,6569.17529,5.840,
5490.69482,189.598,6569.26660,5.840,
5490.78662,187.598,6569.35840,5.840,
5490.87793,187.598,6569.44971,5.840,
5490.96973,187.598,6569.54150,5.840,
5491.06104,187.598,6569.63281,4.840,
5491.15234,188.598,6569.72461,5.840,
5491.24414,187.598,6569.81592,5.840,
5491.33545,187.598,6569.90723,6.840,
5491.42725,187.598,6569.99902,5.840,
5491.51855,187.598,6570.09033,5.840,
5491.61035,187.598,6570.18213,5.840,
5491.70166,187.598,6570.27344,5.840,
5491.79297,186.598,6570.36523,5.840,
5491.88477,186.598,6570.45654,5.840,
5491.97607,186.598,6570.54785,5.840,
5492.06787,187.598,6570.63965,5.840,
5492.15918,187.598,6570.73096,5.840,
5492.25098,186.598,6570.82275,6.840,
5492.34229,186.598,6570.91406,5.840,
5492.43359,186.598,6571.00586,6.840,
5492.52539,186.598,6571.09717,6.840,
5492.61670,186.598,6571.18848,6.840,
5492.70850,186.598,6571.28027,6.840,
5492.79980,186.598,6571.37158,7.840,
5492.89160,186.598,6571.46338,6.840,
5492.98291,186.598,6571.55469,6.840,
5493.07422,185.598,6571.64648,6.840,
5493.16602,185.598,6571.73779,6.840,
5493.25732,185.598,6571.82959,6.840,
5493.34912,185.598,6571.92090,6.840,
5493.44043,185.598,6572.01221,6.840,
5493.53223,185.598,6572.10400,5.840,
5493.62354,186.598,6572.19531,5.840,
5493.71533,185.598,6572.28711,5.840,
5493.80664,185.598,6572.37842,5.840,
5493.89795,185.598,6572.47021,5.840,
5493.98975,185.598,6572.56152,5.840,
5494.08105,185.598,6572.65283,5.840,
5494.17285,185.598,6572.74463,5.840,
5494.26416,184.598,6572.83594,5.840,
5494.35596,185.598,6572.92773,5.840,
5494.44727,184.598,6573.01904,5.840,
5494.53857,184.598,6573.11084,6.840,
5494.63037,184.598,6573.20215,6.840,
5494.72168,184.598,6573.29346,6.840,
5494.81348,184.598,6573.38525,7.840,
5494.90479,184.598,6573.47656,8.840,
5494.99658,184.598,6573.56836,8.840,
5495.08789,185.598,6573.65967,8.840,
5495.17920,184.598,6573.75146,8.840,
5495.27100,184.598,6573.84277,8.840,
5495.36230,184.598,6573.93457,8.840,
5495.45410,184.598,6574.02588,7.840,
5495.54541,184.598,6574.11719,7.840,
5495.63721,183.598,6574.20898,7.840,
5495.72852,183.598,6574.30029,6.840,
5495.82031,184.598,6574.39209,6.840,
5495.91162,183.598,6574.48340,6.840,
5496.00293,183.598,6574.57520,6.840,
5496.09473,183.598,6574.66650,6.840,
5496.18604,183.598,6574.75781,6.840,
5496.27783,183.598,6574.84961,4.840,
5496.36914,183.598,6574.94092,5.840,
5496.46094,183.598,6575.03271,5.840,
5496.55225,183.598,6575.12402,5.840,
5496.64355,183.598,6575.21582,4.840,
5496.73535,183.598,6575.30713,4.840,
5496.82666,183.598,6575.39844,4.840,
5496.91846,183.598,6575.49023,4.840,
5497.00977,183.598,6575.58154,4.840,
5497.10156,182.598,6575.67334,5.840,
5497.19287,182.598,6575.76465,5.840,
5497.28418,182.598,6575.85645,4.840,
5497.37598,182.598,6575.94775,4.840,
5497.46729,182.598,6576.03955,5.840,
5497.55908,181.598,6576.13086,5.840,
5497.65039,182.598,6576.22217,5.840,
5497.74219,182.598,6576.31396,4.840,
5497.83350,182.598,6576.40527,5.840,
5497.92529,182.598,6576.49707,4.840,
5498.01660,182.598,6576.58838,4.840,
5498.10791,182.598,6576.68018,4.840,
5498.19971,182.598,6576.77148,4.840,
5498.29102,181.598,6576.86279,4.840,
5498.38281,182.598,6576.95459,4.840,
5498.47412,181.598,6577.04590,4.840,
5498.56592,182.598,6577.13770,4.840,
5498.65723,181.598,6577.22900,5.840,
5498.74854,181.598,6577.32080,5.840,
5498.84033,181.598,6577.41211,4.840,
5498.93164,181.598,6577.50342,5.840,
5499.02344,181.598,6577.59521,4.840,
5499.11475,181.598,6577.68652,5.840,
5499.20654,180.598,6577.77832,4.840,
5499.29785,180.598,6577.86963,4.840,
5499.38916,181.598,6577.96143,5.840,
5499.48096,181.598,6578.05273,4.840,
5499.57227,181.598,6578.14404,4.840,
5499.66406,180.598,6578.23584,4.840,
5499.75537,181.598,6578.32715,4.840,
5499.84717,180.598,6578.41895,4.840,
5499.93848,180.598,6578.51025,4.840,
5500.03027,181.598,6578.60205,4.840,
5500.12158,180.598,6578.69336,4.840,
5500.21289,180.598,6578.78516,4.840,
5500.30469,180.598,6578.87646,4.840,
5500.39600,180.598,6578.96777,4.840,
5500.48779,180.598,6579.05957,4.840,
5500.57910,179.598,6579.15088,4.840,
5500.67090,179.598,6579.24268,5.840,
5500.76221,180.598,6579.33398,4.840,
5500.85352,179.598,6579.42578,4.840,
5500.94531,180.598,6579.51709,4.840,
5501.03662,179.598,6579.60840,3.840,
5501.12842,179.598,6579.70020,4.840,
5501.21973,179.598,6579.79150,4.840,
5501.31152,179.598,6579.88330,4.840,
5501.40283,179.598,6579.97461,4.840,
5501.49414,179.598,6580.06641,4.840,
5501.58594,179.598,6580.15771,4.840,
5501.67725,179.598,6580.24902,4.840,
5501.76904,179.598,6580.34082,4.840,
5501.86035,179.598,6580.43213,4.840,
5501.95215,179.598,6580.52393,4.840,
5502.04346,179.598,6580.61523,4.840,
5502.13525,179.598,6580.70703,4.840,
5502.22656,179.598,6580.79834,4.840,
5502.31787,178.598,6580.89014,5.840,
5502.40967,179.598,6580.98145,4.840,
5502.50098,179.598,6581.07275,4.840,
5502.59277,178.598,6581.16455,4.840,
5502.68408,178.598,6581.25586,4.840,
5502.77588,178.598,6581.34766,4.840,
5502.86719,178.598,6581.43896,4.840,
5502.95850,178.598,6581.53076,4.840,
5503.05029,178.598,6581.62207,4.840,
5503.14160,178.598,6581.71338,4.840,
5503.23340,178.598,6581.80518,5.840,
5503.32471,178.598,6581.89648,4.840,
5503.41650,178.598,6581.98828,4.840,
5503.50781,177.598,6582.07959,4.840,
5503.59912,177.598,6582.17139,4.840,
5503.69092,178.598,6582.26270,4.840,
5503.78223,177.598,6582.35400,4.840,
5503.87402,177.598,6582.44580,4.840,
5503.96533,178.598,6582.53711,4.840,
5504.05713,177.598,6582.62891,4.840,
5504.14844,177.598,6582.72021,4.840,
5504.24023,177.598,6582.81201,4.840,
5504.33154,177.598,6582.90332,4.840,
5504.42285,177.598,6582.99512,4.840,
5504.51465,177.598,6583.08643,4.840,
5504.60596,177.598,6583.17773,4.840,
5504.69775,177.598,6583.26953,4.840,
5504.78906,177.598,6583.36084,4.840,
5504.88086,177.598,6583.45264,4.840,
5504.97217,177.598,6583.54395,4.840,
5505.06348,176.598,6583.63574,3.840,
5505.15527,177.598,6583.72705,4.840,
5505.24658,177.598,6583.81836,4.840,
5505.33838,177.598,6583.91016,4.840,
5505.42969,176.598,6584.00146,4.840,
5505.52148,176.598,6584.09326,4.840,
5505.61279,176.598,6584.18457,3.840,
5505.70410,175.598,6584.27637,4.840,
5505.79590,176.598,6584.36768,4.840,
5505.88721,176.598,6584.45898,4.840,
5505.97900,175.598,6584.55078,4.840,
5506.07031,175.598,6584.64209,3.840,
5506.16211,175.598,6584.73389,3.840,
5506.25342,175.598,6584.82520,4.840,
5506.34473,175.598,6584.91699,4.840,
5506.43652,175.598,6585.00830,3.840,
5506.52783,175.598,6585.10010,3.840,
5506.61963,175.598,6585.19141,4.840,
5506.71094,175.598,6585.28271,3.840,
5506.80273,176.598,6585.37451,3.840,
5506.89404,175.598,6585.46582,3.840,
5506.98584,175.598,6585.55762,3.840,
5507.07715,175.598,6585.64893,3.840,
5507.16846,175.598,6585.74072,3.840,
5507.26025,175.598,6585.83203,3.840,
5507.35156,175.598,6585.92334,3.840,
5507.44336,175.598,6586.01514,4.840,
5507.53467,175.598,6586.10645,4.840,
5507.62646,175.598,6586.19824,3.840,
5507.71777,174.598,6586.28955,4.840,
5507.80908,173.598,6586.38135,3.840,
5507.90088,173.598,6586.47266,4.840,
5507.99219,174.598,6586.56396,3.840,
5508.08398,173.598,6586.65576,4.840,
5508.17529,173.598,6586.74707,4.840,
5508.26709,174.598,6586.83887,4.840,
5508.35840,174.598,6586.93018,3.840,
5508.44971,173.598,6587.02197,4.840,
5508.54150,173.598,6587.11328,3.840,
5508.63281,174.598,6587.20508,3.840,
5508.72461,174.598,6587.29639,3.840,
5508.81592,173.598,6587.38770,3.840,
5508.90771,174.598,6587.47949,4.840,
5508.99902,173.598,6587.57080,3.840,
5509.09082,173.598,6587.66260,4.840,
5509.18213,173.598,6587.75391,3.840,
5509.27344,173.598,6587.84570,4.840,
5509.36523,173.598,6587.93701,3.840,
5509.45654,173.598,6588.02832,3.840,
5509.54834,173.598,6588.12012,4.840,
5509.63965,173.598,6588.21143,4.840,
5509.73145,173.598,6588.30322,4.840,
5509.82275,173.598,6588.39453,3.840,
5509.91406,172.598,6588.48633,4.840,
5510.00586,173.598,6588.57764,4.840,
5510.09717,173.598,6588.66895,3.840,
5510.18896,173.598,6588.76074,4.840,
5510.28027,173.598,6588.85205,3.840,
5510.37207,173.598,6588.94385,4.840,
5510.46338,173.598,6589.03516,3.840,
5510.55469,172.598,6589.12695,4.840,
5510.64648,172.598,6589.21826,3.840,
5510.73779,173.598,6589.31006,4.840,
5510.82959,172.598,6589.40137,3.840,
5510.92090,172.598,6589.49268,4.840,
5511.01270,172.598,6589.58447,4.840,
5511.10400,172.598,6589.67578,4.840,
5511.19580,173.598,6589.76758,3.840,
5511.28711,172.598,6589.85889,3.840,
5511.37842,172.598,6589.95068,4.840,
5511.47021,172.598,6590.04199,5.840,
5511.56152,172.598,6590.13330,6.840,
5511.65332,171.598,6590.22510,6.840,
5511.74463,172.598,6590.31641,7.840,
5511.83643,171.598,6590.40820,8.840,
5511.92773,171.598,6590.49951,8.840,
5512.01904,171.598,6590.59131,7.840,
5512.11084,171.598,6590.68262,8.840,
5512.20215,171.598,6590.77393,7.840,
5512.29395,171.598,6590.86572,7.840,
5512.38525,171.598,6590.95703,7.840,
5512.47705,171.598,6591.04883,7.840,
5512.56836,171.598,6591.14014,6.840,
5512.65967,171.598,6591.23193,6.840,
5512.75146,171.598,6591.32324,6.840,
5512.84277,171.598,6591.41455,5.840,
5512.93457,171.598,6591.50635,5.840,
5513.02588,170.598,6591.59766,5.840,
5513.11768,171.598,6591.68945,4.840,
5513.20898,171.598,6591.78076,4.840,
5513.30078,170.598,6591.87256,5.840,
5513.39209,170.598,6591.96387,4.840,
5513.48340,170.598,6592.05566,4.840,
5513.57520,170.598,6592.14697,4.840,
5513.66650,170.598,6592.23828,5.840,
5513.75830,170.598,6592.33008,4.840,
5513.84961,170.598,6592.42139,4.840,
5513.94141,169.598,6592.51318,3.840,
5514.03271,170.598,6592.60449,3.840,
5514.12402,170.598,6592.69629,2.840,
5514.21582,170.598,6592.78760,2.840,
5514.30713,169.598,6592.87891,2.840,
5514.39893,170.598,6592.97070,1.840,
5514.49023,170.598,6593.06201,2.840,
5514.58203,170.598,6593.15381,2.840,
5514.67334,170.598,6593.24512,2.840,
5514.76465,170.598,6593.33691,2.840,
5514.85645,169.598,6593.42822,3.840,
5514.94775,169.598,6593.51953,3.840,
5515.03955,169.598,6593.61133,3.840,
5515.13086,169.598,6593.70264,3.840,
5515.22266,169.598,6593.79443,4.840,
5515.31396,169.598,6593.88574,3.840,
5515.40576,169.598,6593.97754,3.840,
5515.49707,169.598,6594.06885,4.840,
5515.58838,169.598,6594.16064,3.840,
5515.68018,169.598,6594.25195,3.840,
5515.77148,169.598,6594.34326,4.840,
5515.86328,169.598,6594.43506,3.840,
5515.95459,168.598,6594.52637,3.840,
5516.04639,168.598,6594.61816,3.840,
5516.13770,168.598,6594.70947,4.840,
5516.22900,169.598,6594.80127,4.840,
5516.32080,169.598,6594.89258,3.840,
5516.41211,168.598,6594.98389,3.840,
5516.50391,168.598,6595.07568,3.840,
5516.59521,168.598,6595.16699,4.840,
5516.68701,168.598,6595.25879,3.840,
5516.77832,168.598,6595.35010,3.840,
5516.86963,168.598,6595.44189,4.840,
5516.96143,168.598,6595.53320,4.840,
5517.05273,168.598,6595.62451,4.840,
5517.14453,168.598,6595.71631,3.840,
5517.23584,168.598,6595.80762,4.840,
5517.32764,167.598,6595.89941,3.840,
5517.41895,168.598,6595.99072,3.840,
5517.51074,167.598,6596.08252,3.840,
5517.60205,167.598,6596.17383,4.840,
5517.69336,167.598,6596.26563,3.840,
5517.78516,167.598,6596.35693,3.840,
5517.87646,167.598,6596.44824,3.840,
5517.96826,167.598,6596.54004,4.840,
5518.05957,167.598,6596.63135,3.840,
5518.15137,167.598,6596.72314,3.840,
5518.24268,167.598,6596.81445,3.840,
5518.33398,167.598,6596.90625,3.840,
5518.42578,167.598,6596.99756,3.840,
5518.51709,167.598,6597.08887,4.840,
5518.60889,167.598,6597.18066,4.840,
5518.70020,167.598,6597.27197,3.840,
5518.79199,167.598,6597.36377,4.840,
5518.88330,167.598,6597.45508,4.840,
5518.97461,166.598,6597.54688,3.840,
5519.06641,166.598,6597.63818,4.840,
5519.15771,166.598,6597.72949,4.840,
5519.24951,167.598,6597.82129,3.840,
5519.34082,166.598,6597.91260,3.840,
5519.43262,166.598,6598.00439,4.840,
5519.52393,166.598,6598.09570,3.840,
5519.61523,166.598,6598.18750,3.840,
5519.70703,166.598,6598.27881,4.840,
5519.79834,166.598,6598.37061,4.840,
5519.89014,165.598,6598.46191,3.840,
5519.98145,166.598,6598.55322,3.840,
5520.07324,165.598,6598.64502,3.840,
5520.16455,166.598,6598.73633,3.840,
5520.25635,165.598,6598.82813,4.840,
5520.34766,166.598,6598.91943,4.840,
5520.43896,165.598,6599.01123,3.840,
5520.53076,165.598,6599.10254,4.840,
5520.62207,165.598,6599.19385,4.840,
5520.71387,165.598,6599.28564,4.840,
5520.80518,165.598,6599.37695,3.840,
5520.89697,165.598,6599.46875,4.840,
5520.98828,165.598,6599.56006,4.840,
5521.07959,165.598,6599.65186,3.840,
5521.17139,165.598,6599.74316,3.840,
5521.26270,165.598,6599.83447,3.840,
5521.35449,165.598,6599.92627,3.840,
5521.44580,166.598,6600.01758,3.840,
5521.53760,165.598,6600.10938,3.840,
5521.62891,164.598,6600.20068,4.840,
5521.72021,165.598,6600.29248,3.840,
5521.81201,164.598,6600.38379,3.840,
5521.90332,164.598,6600.47559,3.840,
5521.99512,164.598,6600.56689,3.840,
5522.08643,164.598,6600.65820,3.840,
5522.17822,164.598,6600.75000,4.840,
5522.26953,164.598,6600.84131,3.840,
5522.36133,163.598,6600.93311,3.840,
5522.45264,164.598,6601.02441,3.840,
5522.54395,163.598,6601.11621,3.840,
5522.63574,163.598,6601.20752,4.840,
5522.72705,163.598,6601.29883,3.840,
5522.81885,163.598,6601.39063,3.840,
5522.91016,164.598,6601.48193,4.840,
5523.00195,163.598,6601.57373,3.840,
5523.09326,163.598,6601.66504,3.840,
5523.18457,163.598,6601.75684,3.840,
5523.27637,163.598,6601.84814,3.840,
5523.36768,163.598,6601.93945,3.840,
5523.45947,163.598,6602.03125,3.840,
5523.55078,163.598,6602.12256,4.840,
5523.64258,163.598,6602.21436,3.840,
5523.73389,163.598,6602.30566,4.840,
5523.82520,163.598,6602.39746,4.840,
5523.91699,163.598,6602.48877,3.840,
5524.00830,163.598,6602.58057,3.840,
5524.10010,162.598,6602.67188,3.840,
5524.19141,163.598,6602.76318,4.840,
5524.28320,163.598,6602.85498,3.840,
5524.37451,163.598,6602.94629,3.840,
5524.46631,162.598,6603.03809,3.840,
5524.55762,162.598,6603.12939,3.840,
5524.64893,162.598,6603.22119,4.840,
5524.74072,162.598,6603.31250,3.840,
5524.83203,162.598,6603.40381,3.840,
5524.92383,162.598,6603.49561,3.840,
5525.01514,162.598,6603.58691,4.840,
5525.10693,162.598,6603.67871,3.840,
5525.19824,162.598,6603.77002,3.840,
5525.28955,161.598,6603.86182,3.840,
5525.38135,162.598,6603.95313,3.840,
5525.47266,162.598,6604.04443,3.840,
5525.56445,161.598,6604.13623,3.840,
5525.65576,161.598,6604.22754,3.840,
5525.74756,161.598,6604.31934,3.840,
5525.83887,162.598,6604.41064,3.840,
5525.93018,161.598,6604.50244,4.840,
5526.02197,161.598,6604.59375,3.840,
5526.11328,161.598,6604.68506,3.840,
5526.20508,161.598,6604.77686,4.840,
5526.29639,161.598,6604.86816,3.840,
5526.38818,161.598,6604.95996,3.840,
5526.47949,161.598,6605.05127,4.840,
5526.57129,161.598,6605.14307,3.840,
5526.66260,160.598,6605.23438,2.840,
5526.75391,160.598,6605.32617,3.840,
5526.84570,160.598,6605.41748,3.840,
5526.93701,160.598,6605.50879,3.840,
5527.02881,160.598,6605.60059,3.840,
5527.12012,160.598,6605.69189,3.840,
5527.21191,160.598,6605.78369,3.840,
5527.30322,161.598,6605.87500,3.840,
5527.39453,160.598,6605.96680,3.840,
5527.48633,160.598,6606.05811,3.840,
5527.57764,160.598,6606.14941,3.840,
5527.66943,160.598,6606.24121,3.840,
5527.76074,159.598,6606.33252,3.840,
5527.85254,160.598,6606.42432,3.840,
5527.94385,160.598,6606.51563,3.840,
5528.03516,159.598,6606.60742,3.840,
5528.12695,159.598,6606.69873,3.840,
5528.21826,159.598,6606.79004,3.840,
5528.31006,159.598,6606.88184,3.840,
5528.40137,159.598,6606.97314,3.840,
5528.49316,159.598,6607.06494,3.840,
5528.58447,159.598,6607.15625,3.840,
5528.67627,158.598,6607.24805,3.840,
5528.76758,159.598,6607.33936,3.840,
5528.85889,159.598,6607.43115,3.840,
5528.95068,159.598,6607.52246,3.840,
5529.04199,159.598,6607.61377,3.840,
5529.13379,159.598,6607.70557,2.840,
5529.22510,160.598,6607.79688,3.840,
5529.31689,160.598,6607.88867,3.840,
5529.40820,160.598,6607.97998,4.840,
5529.49951,159.598,6608.07178,3.840,
5529.59131,160.598,6608.16309,3.840,
5529.68262,159.598,6608.25439,3.840,
5529.77441,159.598,6608.34619,3.840,
5529.86572,159.598,6608.43750,3.840,
5529.95752,159.598,6608.52930,3.840,
5530.04883,159.598,6608.62061,3.840,
5530.14014,158.598,6608.71240,3.840,
5530.23193,158.598,6608.80371,3.840,
5530.32324,158.598,6608.89502,3.840,
5530.41504,158.598,6608.98682,4.840,
5530.50635,158.598,6609.07813,4.840,
5530.59814,158.598,6609.16992,4.840,
5530.68945,157.598,6609.26123,4.840,
5530.78076,157.598,6609.35303,4.840,
5530.87256,158.598,6609.44434,5.840,
5530.96387,158.598,6609.53613,4.840,
5531.05566,157.598,6609.62744,4.840,
5531.14697,157.598,6609.71875,4.840,
5531.23877,157.598,6609.81055,4.840,
5531.33008,156.598,6609.90186,4.840,
5531.42188,156.598,6609.99365,4.840,
5531.51318,157.598,6610.08496,4.840,
5531.60449,157.598,6610.17676,4.840,
5531.69629,157.598,6610.26807,3.840,
5531.78760,157.598,6610.35938,4.840,
5531.87939,156.598,6610.45117,3.840,
5531.97070,156.598,6610.54248,3.840,
5532.06250,156.598,6610.63428,3.840,
5532.15381,156.598,6610.72559,3.840,
5532.24512,156.598,6610.81738,3.840,
5532.33691,156.598,6610.90869,3.840,
5532.42822,156.598,6611.00000,3.840,
5532.52002,156.598,6611.09180,3.840,
5532.61133,156.598,6611.18311,4.840,
5532.70313,155.598,6611.27490,4.840,
5532.79443,156.598,6611.36621,5.840,
5532.88574,155.598,6611.45801,5.840,
5532.97754,155.598,6611.54932,6.840,
5533.06885,156.598,6611.64111,6.840,
5533.16064,156.598,6611.73242,6.840,
5533.25195,155.598,6611.82373,6.840,
5533.34375,156.598,6611.91553,7.840,
5533.43506,156.598,6612.00684,6.840,
5533.52686,155.598,6612.09863,6.840,
5533.61816,155.598,6612.18994,6.840,
5533.70947,155.598,6612.28174,6.840,
5533.80127,155.598,6612.37305,6.840,
5533.89258,155.598,6612.46436,5.840,
5533.98438,155.598,6612.55615,5.840,
5534.07568,155.598,6612.64746,5.840,
5534.16748,155.598,6612.73926,5.840,
5534.25879,155.598,6612.83057,4.840,
5534.35010,154.598,6612.92236,4.840,
5534.44189,155.598,6613.01367,4.840,
5534.53320,154.598,6613.10498,3.840,
5534.62500,155.598,6613.19678,3.840,
5534.71631,155.598,6613.28809,3.840,
5534.80811,154.598,6613.37988,4.840,
5534.89941,154.598,6613.47119,3.840,
5534.99072,155.598,6613.56299,3.840,
5535.08252,154.598,6613.65430,3.840,
5535.17383,154.598,6613.74609,3.840,
5535.26563,155.598,6613.83740,4.840,
5535.35693,154.598,6613.92871,3.840,
5535.44873,154.598,6614.02051,3.840,
5535.54004,154.598,6614.11182,3.840,
5535.63184,154.598,6614.20361,3.840,
5535.72314,154.598,6614.29492,3.840,
5535.81445,154.598,6614.38672,3.840,
5535.90625,153.598,6614.47803,3.840,
5535.99756,153.598,6614.56934,3.840,
5536.08936,154.598,6614.66113,3.840,
5536.18066,154.598,6614.75244,3.840,
5536.27246,153.598,6614.84424,3.840,
5536.36377,153.598,6614.93555,3.840,
5536.45508,153.598,6615.02734,3.840,
5536.54688,154.598,6615.11865,3.840,
5536.63818,153.598,6615.20996,3.840,
5536.72998,154.598,6615.30176,3.840,
5536.82129,153.598,6615.39307,3.840,
5536.91309,153.598,6615.48486,3.840,
5537.00439,153.598,6615.57617,3.840,
5537.09570,153.598,6615.66797,3.840,
5537.18750,153.598,6615.75928,3.840,
5537.27881,152.598,6615.85059,3.840,
5537.37061,153.598,6615.94238,3.840,
5537.46191,153.598,6616.03369,3.840,
5537.55371,153.598,6616.12549,3.840,
5537.64502,153.598,6616.21680,3.840,
5537.73682,153.598,6616.30859,3.840,
5537.82813,152.598,6616.39990,3.840,
5537.91943,153.598,6616.49170,3.840,
5538.01123,152.598,6616.58301,3.840,
5538.10254,152.598,6616.67432,3.840,
5538.19434,152.598,6616.76611,3.840,
5538.28564,152.598,6616.85742,2.840,
5538.37744,152.598,6616.94922,3.840,
5538.46875,152.598,6617.04053,3.840,
5538.56006,152.598,6617.13232,3.840,
5538.65186,152.598,6617.22363,2.840,
5538.74316,151.598,6617.31494,3.840,
5538.83496,151.598,6617.40674,3.840,
5538.92627,152.598,6617.49805,3.840,
5539.01807,152.598,6617.58984,3.840,
5539.10938,151.598,6617.68115,2.840,
5539.20068,151.598,6617.77295,3.840,
5539.29248,151.598,6617.86426,2.840,
5539.38379,151.598,6617.95557,3.840,
5539.47559,151.598,6618.04736,3.840,
5539.56689,151.598,6618.13867,3.840,
5539.65869,151.598,6618.23047,3.840,
5539.75000,151.598,6618.32178,3.840,
5539.84180,151.598,6618.41357,2.840,
5539.93311,151.598,6618.50488,3.840,
5540.02441,151.598,6618.59668,3.840,
5540.11621,151.598,6618.68799,3.840,
5540.20752,151.598,6618.77930,2.840,
5540.29932,150.598,6618.87109,3.840,
5540.39063,151.598,6618.96240,3.840,
5540.48242,151.598,6619.05420,3.840,
5540.57373,150.598,6619.14551,3.840,
5540.66504,150.598,6619.23730,3.840,
5540.75684,150.598,6619.32861,3.840,
5540.84814,150.598,6619.41992,3.840,
5540.93994,150.598,6619.51172,3.840,
5541.03125,150.598,6619.60303,2.840,
5541.12305,150.598,6619.69482,3.840,
5541.21436,150.598,6619.78613,3.840,
5541.30566,150.598,6619.87793,3.840,
5541.39746,150.598,6619.96924,3.840,
5541.48877,150.598,6620.06055,3.840,
5541.58057,149.598,6620.15234,3.840,
5541.67188,150.598,6620.24365,3.840,
5541.76367,150.598,6620.33545,2.840,
5541.85498,149.598,6620.42676,3.840,
5541.94678,150.598,6620.51855,2.840,
5542.03809,150.598,6620.60986,2.840,
5542.12939,149.598,6620.70166,3.840,
5542.22119,150.598,6620.79297,3.840,
5542.31250,149.598,6620.88428,3.840,
5542.40430,149.598,6620.97607,2.840,
5542.49561,149.598,6621.06738,3.840,
5542.58740,149.598,6621.15918,3.840,
5542.67871,149.598,6621.25049,2.840,
5542.77002,148.598,6621.34229,3.840,
5542.86182,149.598,6621.43359,3.840,
5542.95313,149.598,6621.52490,2.840,
5543.04492,148.598,6621.61670,3.840,
5543.13623,149.598,6621.70801,3.840,
5543.22803,149.598,6621.79980,3.840,
5543.31934,148.598,6621.89111,3.840,
5543.41064,149.598,6621.98291,3.840,
5543.50244,149.598,6622.07422,2.840,
5543.59375,148.598,6622.16553,2.840,
5543.68555,149.598,6622.25732,3.840,
5543.77686,148.598,6622.34863,3.840,
5543.86865,148.598,6622.44043,3.840,
5543.95996,148.598,6622.53174,2.840,
5544.05127,148.598,6622.62354,3.840,
5544.14307,148.598,6622.71484,2.840,
5544.23438,147.598,6622.80664,3.840,
5544.32617,147.598,6622.89795,2.840,
5544.41748,148.598,6622.98926,3.840,
5544.50928,147.598,6623.08105,3.840,
5544.60059,147.598,6623.17236,2.840,
5544.69238,147.598,6623.26416,3.840,
5544.78369,147.598,6623.35547,2.840,
5544.87500,148.598,6623.44727,2.840,
5544.96680,147.598,6623.53857,3.840,
5545.05811,147.598,6623.62988,2.840,
5545.14990,147.598,6623.72168,3.840,
5545.24121,147.598,6623.81299,3.840,
5545.33301,147.598,6623.90479,2.840,
5545.42432,147.598,6623.99609,3.840,
5545.51563,147.598,6624.08789,3.840,
5545.60742,147.598,6624.17920,3.840,
5545.69873,147.598,6624.27051,2.840,
5545.79053,147.598,6624.36230,3.840,
5545.88184,147.598,6624.45361,3.840,
5545.97363,147.598,6624.54541,2.840,
5546.06494,147.598,6624.63672,2.840,
5546.15625,146.598,6624.72852,3.840,
5546.24805,147.598,6624.81982,3.840,
5546.33936,147.598,6624.91162,3.840,
5546.43115,146.598,6625.00293,3.840,
5546.52246,147.598,6625.09424,3.840,
5546.61426,147.598,6625.18604,3.840,
5546.70557,146.598,6625.27734,3.840,
5546.79736,146.598,6625.36914,2.840,
5546.88867,146.598,6625.46045,3.840,
5546.97998,146.598,6625.55225,3.840,
5547.07178,146.598,6625.64355,3.840,
5547.16309,146.598,6625.73486,3.840,
5547.25488,146.598,6625.82666,2.840,
5547.34619,145.598,6625.91797,3.840,
5547.43799,146.598,6626.00977,3.840,
5547.52930,145.598,6626.10107,2.840,
5547.62061,145.598,6626.19287,3.840,
5547.71240,145.598,6626.28418,3.840,
5547.80371,146.598,6626.37549,2.840,
5547.89551,145.598,6626.46729,2.840,
5547.98682,145.598,6626.55859,2.840,
5548.07861,145.598,6626.65039,2.840,
5548.16992,145.598,6626.74170,2.840,
5548.26123,145.598,6626.83350,2.840,
5548.35303,145.598,6626.92480,2.840,
5548.44434,145.598,6627.01660,3.840,
5548.53613,145.598,6627.10791,2.840,
5548.62744,144.598,6627.19922,2.840,
5548.71924,145.598,6627.29102,3.840,
5548.81055,145.598,6627.38232,2.840,
5548.90234,145.598,6627.47412,2.840,
5548.99365,145.598,6627.56543,2.840,
5549.08496,145.598,6627.65723,2.840,
5549.17676,144.598,6627.74854,2.840,
5549.26807,145.598,6627.83984,2.840,
5549.35986,145.598,6627.93164,2.840,
5549.45117,144.598,6628.02295,2.840,
5549.54297,144.598,6628.11475,3.840,
5549.63428,144.598,6628.20605,3.840,
5549.72559,144.598,6628.29785,3.840,
5549.81738,144.598,6628.38916,3.840,
5549.90869,145.598,6628.48047,4.840,
5550.00049,144.598,6628.57227,3.840,
5550.09180,144.598,6628.66357,4.840,
5550.18359,143.598,6628.75537,4.840,
5550.27490,143.598,6628.84668,3.840,
5550.36621,143.598,6628.93848,3.840,
5550.45801,143.598,6629.02979,3.840,
5550.54932,143.598,6629.12109,3.840,
5550.64111,143.598,6629.21289,3.840,
5550.73242,143.598,6629.30420,3.840,
5550.82422,143.598,6629.39600,2.840,
5550.91553,143.598,6629.48730,2.840,
5551.00732,143.598,6629.57910,3.840,
5551.09863,143.598,6629.67041,3.840,
5551.18994,143.598,6629.76221,2.840,
5551.28174,143.598,6629.85352,2.840,
5551.37305,143.598,6629.94482,3.840,
5551.46484,144.598,6630.03662,1.840,
5551.55615,143.598,6630.12793,1.840,
5551.64795,143.598,6630.21973,1.840,
5551.73926,143.598,6630.31104,0.840,
5551.83057,143.598,6630.40283,0.840,
5551.92236,143.598,6630.49414,0.840,
5552.01367,143.598,6630.58545,1.840,
5552.10547,143.598,6630.67725,1.840,
5552.19678,143.598,6630.76855,0.840,
5552.28857,143.598,6630.86035,1.840,
5552.37988,142.598,6630.95166,1.840,
5552.47119,142.598,6631.04346,1.840,
5552.56299,142.598,6631.13477,2.840,
5552.65430,142.598,6631.22607,2.840,
5552.74609,142.598,6631.31787,2.840,
5552.83740,142.598,6631.40918,3.840,
5552.92920,142.598,6631.50098,3.840,
5553.02051,142.598,6631.59229,2.840,
5553.11230,142.598,6631.68408,3.840,
5553.20361,141.598,6631.77539,3.840,
5553.29492,141.598,6631.86719,2.840,
5553.38672,142.598,6631.95850,2.840,
5553.47803,141.598,6632.04980,2.840,
5553.56982,142.598,6632.14160,3.840,
5553.66113,142.598,6632.23291,2.840,
5553.75293,141.598,6632.32471,2.840,
5553.84424,141.598,6632.41602,2.840,
5553.93555,141.598,6632.50781,2.840,
5554.02734,141.598,6632.59912,2.840,
5554.11865,141.598,6632.69043,2.840,
5554.21045,141.598,6632.78223,2.840,
5554.30176,141.598,6632.87354,3.840,
5554.39355,141.598,6632.96533,2.840,
5554.48486,141.598,6633.05664,2.840,
5554.57617,141.598,6633.14844,2.840,
5554.66797,141.598,6633.23975,2.840,
5554.75928,140.598,6633.33105,2.840,
5554.85107,141.598,6633.42285,2.840,
5554.94238,140.598,6633.51416,2.840,
5555.03418,140.598,6633.60596,2.840,
5555.12549,140.598,6633.69727,2.840,
5555.21729,140.598,6633.78906,2.840,
5555.30859,140.598,6633.88037,2.840,
5555.39990,140.598,6633.97217,2.840,
5555.49170,140.598,6634.06348,2.840,
5555.58301,140.598,6634.15479,2.840,
5555.67480,140.598,6634.24658,2.840,
5555.76611,140.598,6634.33789,3.840,
5555.85791,140.598,6634.42969,2.840,
5555.94922,140.598,6634.52100,2.840,
5556.04053,140.598,6634.61279,3.840,
5556.13232,140.598,6634.70410,2.840,
5556.22363,140.598,6634.79541,2.840,
5556.31543,140.598,6634.88721,3.840,
5556.40674,139.598,6634.97852,2.840,
5556.49854,139.598,6635.07031,2.840,
5556.58984,140.598,6635.16162,2.840,
5556.68115,140.598,6635.25342,2.840,
5556.77295,140.598,6635.34473,2.840,
5556.86426,139.598,6635.43604,2.840,
5556.95605,140.598,6635.52783,2.840,
5557.04736,140.598,6635.61914,2.840,
5557.13916,139.598,6635.71094,2.840,
5557.23047,139.598,6635.80225,3.840,
5557.32178,140.598,6635.89404,2.840,
5557.41357,139.598,6635.98535,2.840,
5557.50488,139.598,6636.07715,2.840,
5557.59668,139.598,6636.16846,2.840,
5557.68799,139.598,6636.25977,2.840,
5557.77979,139.598,6636.35156,2.840,
5557.87109,139.598,6636.44287,3.840,
5557.96289,139.598,6636.53467,2.840,
5558.05420,139.598,6636.62598,2.840,
5558.14551,139.598,6636.71777,2.840,
5558.23730,138.598,6636.80908,2.840,
5558.32861,138.598,6636.90039,2.840,
5558.42041,138.598,6636.99219,2.840,
5558.51172,138.598,6637.08350,2.840,
5558.60352,138.598,6637.17529,2.840,
5558.69482,138.598,6637.26660,3.840,
5558.78613,138.598,6637.35840,3.840,
5558.87793,138.598,6637.44971,2.840,
5558.96924,138.598,6637.54102,3.840,
5559.06104,138.598,6637.63281,2.840,
5559.15234,138.598,6637.72412,2.840,
5559.24414,137.598,6637.81592,2.840,
5559.33545,138.598,6637.90723,3.840,
5559.42676,138.598,6637.99902,3.840,
5559.51855,139.598,6638.09033,2.840,
5559.60986,137.598,6638.18213,2.840,
5559.70166,138.598,6638.27344,2.840,
5559.79297,137.598,6638.36475,3.840,
5559.88477,137.598,6638.45654,3.840,
5559.97607,137.598,6638.54785,3.840,
5560.06787,137.598,6638.63965,2.840,
5560.15918,137.598,6638.73096,3.840,
5560.25049,137.598,6638.82275,3.840,
5560.34229,137.598,6638.91406,3.840,
5560.43359,136.598,6639.00537,3.840,
5560.52539,137.598,6639.09717,3.840,
5560.61670,136.598,6639.18848,3.840,
5560.70850,137.598,6639.28027,2.840,
5560.79980,136.598,6639.37158,3.840,
5560.89111,137.598,6639.46338,3.840,
5560.98291,137.598,6639.55469,2.840,
5561.07422,136.598,6639.64600,2.840,
5561.16602,136.598,6639.73779,2.840,
5561.25732,137.598,6639.82910,3.840,
5561.34912,136.598,6639.92090,3.840,
5561.44043,136.598,6640.01221,3.840,
5561.53174,136.598,6640.10400,3.840,
5561.62354,136.598,6640.19531,3.840,
5561.71484,136.598,6640.28662,2.840,
5561.80664,136.598,6640.37842,3.840,
5561.89795,136.598,6640.46973,3.840,
5561.98975,136.598,6640.56152,2.840,
5562.08105,135.598,6640.65283,3.840,
5562.17285,136.598,6640.74463,3.840,
5562.26416,136.598,6640.83594,3.840,
5562.35547,135.598,6640.92773,3.840,
5562.44727,136.598,6641.01904,3.840,
5562.53857,135.598,6641.11035,2.840,
5562.63037,135.598,6641.20215,3.840,
5562.72168,135.598,6641.29346,2.840,
5562.81348,136.598,6641.38525,2.840,
5562.90479,135.598,6641.47656,2.840,
5562.99609,135.598,6641.56836,3.840,
5563.08789,135.598,6641.65967,3.840,
5563.17920,135.598,6641.75098,2.840,
5563.27100,135.598,6641.84277,2.840,
5563.36230,134.598,6641.93408,2.840,
5563.45410,134.598,6642.02588,2.840,
5563.54541,134.598,6642.11719,2.840,
5563.63672,134.598,6642.20898,3.840,
5563.72852,134.598,6642.30029,2.840,
5563.81982,134.598,6642.39160,2.840,
5563.91162,135.598,6642.48340,2.840,
5564.00293,135.598,6642.57471,2.840,
5564.09473,134.598,6642.66650,2.840,
5564.18604,134.598,6642.75781,2.840,
5564.27783,134.598,6642.84961,2.840,
5564.36914,134.598,6642.94092,3.840,
5564.46045,134.598,6643.03271,2.840,
5564.55225,134.598,6643.12402,3.840,
5564.64355,134.598,6643.21533,2.840,
5564.73535,133.598,6643.30713,2.840,
5564.82666,133.598,6643.39844,2.840,
5564.91846,134.598,6643.49023,2.840,
5565.00977,134.598,6643.58154,2.840,
5565.10107,133.598,6643.67334,2.840,
5565.19287,133.598,6643.76465,2.840,
5565.28418,134.598,6643.85596,2.840,
5565.37598,134.598,6643.94775,2.840,
5565.46729,133.598,6644.03906,2.840,
5565.55908,133.598,6644.13086,3.840,
5565.65039,133.598,6644.22217,2.840,
5565.74170,133.598,6644.31396,2.840,
5565.83350,133.598,6644.40527,3.840,
5565.92480,133.598,6644.49658,3.840,
5566.01660,133.598,6644.58838,4.840,
5566.10791,132.598,6644.67969,3.840,
5566.19971,133.598,6644.77148,2.840,
5566.29102,132.598,6644.86279,2.840,
5566.38281,132.598,6644.95459,3.840,
5566.47412,133.598,6645.04590,3.840,
5566.56543,132.598,6645.13770,2.840,
5566.65723,132.598,6645.22900,2.840,
5566.74854,132.598,6645.32031,2.840,
5566.84033,133.598,6645.41211,2.840,
5566.93164,132.598,6645.50342,2.840,
5567.02344,132.598,6645.59521,3.840,
5567.11475,132.598,6645.68652,2.840,
5567.20605,132.598,6645.77832,2.840,
5567.29785,132.598,6645.86963,2.840,
5567.38916,132.598,6645.96094,2.840,
5567.48096,132.598,6646.05273,2.840,
5567.57227,131.598,6646.14404,1.840,
5567.66406,132.598,6646.23584,1.840,
5567.75537,132.598,6646.32715,1.840,
5567.84668,132.598,6646.41895,1.840,
5567.93848,132.598,6646.51025,1.840,
5568.02979,132.598,6646.60156,1.840,
5568.12158,132.598,6646.69336,1.840,
5568.21289,132.598,6646.78467,2.840,
5568.30469,132.598,6646.87646,2.840,
5568.39600,132.598,6646.96777,2.840,
5568.48730,132.598,6647.05957,2.840,
5568.57910,132.598,6647.15088,2.840,
5568.67041,131.598,6647.24268,2.840,
5568.76221,131.598,6647.33398,2.840,
5568.85352,131.598,6647.42529,2.840,
5568.94531,131.598,6647.51709,2.840,
5569.03662,131.598,6647.60840,2.840,
5569.12842,131.598,6647.70020,2.840,
5569.21973,131.598,6647.79150,2.840,
5569.31104,130.598,6647.88330,2.840,
5569.40283,131.598,6647.97461,2.840,
5569.49414,131.598,6648.06592,2.840,
5569.58594,131.598,6648.15771,2.840,
5569.67725,131.598,6648.24902,1.840,
5569.76904,131.598,6648.34082,1.840,
5569.86035,130.598,6648.43213,0.840,
5569.95166,130.598,6648.52393,0.840,
5570.04346,129.598,6648.61523,-0.160,
5570.13477,129.598,6648.70654,-0.160,
5570.22656,129.598,6648.79834,-0.160,
5570.31787,129.598,6648.88965,0.840,
5570.40967,130.598,6648.98145,0.840,
5570.50098,129.598,6649.07275,0.840,
5570.59229,129.598,6649.16455,0.840,
5570.68408,130.598,6649.25586,0.840,
5570.77539,130.598,6649.34766,1.840,
5570.86719,129.598,6649.43896,1.840,
5570.95850,129.598,6649.53027,1.840,
5571.05029,130.598,6649.62207,1.840,
5571.14160,129.598,6649.71338,1.840,
5571.23340,129.598,6649.80518,2.840,
5571.32471,130.598,6649.89648,2.840,
5571.41602,129.598,6649.98828,2.840,
5571.50781,129.598,6650.07959,2.840,
5571.59912,129.598,6650.17090,2.840,
5571.69092,130.598,6650.26270,3.840,
5571.78223,129.598,6650.35400,2.840,
5571.87402,129.598,6650.44580,3.840,
5571.96533,129.598,6650.53711,3.840,
5572.05664,129.598,6650.62891,2.840,
5572.14844,128.598,6650.72021,2.840,
5572.23975,129.598,6650.81152,3.840,
5572.33154,128.598,6650.90332,2.840,
5572.42285,129.598,6650.99463,3.840,
5572.51465,129.598,6651.08643,3.840,
5572.60596,129.598,6651.17773,2.840,
5572.69727,129.598,6651.26953,2.840,
5572.78906,129.598,6651.36084,3.840,
5572.88037,129.598,6651.45264,2.840,
5572.97217,129.598,6651.54395,2.840,
5573.06348,128.598,6651.63525,3.840,
5573.15527,128.598,6651.72705,3.840,
5573.24658,128.598,6651.81836,3.840,
5573.33838,128.598,6651.91016,3.840,
5573.42969,128.598,6652.00146,3.840,
5573.52100,128.598,6652.09326,3.840,
5573.61279,128.598,6652.18457,2.840,
5573.70410,128.598,6652.27588,3.840,
5573.79590,128.598,6652.36768,3.840,
5573.88721,128.598,6652.45898,2.840,
5573.97900,128.598,6652.55078,2.840,
5574.07031,127.598,6652.64209,3.840,
5574.16162,128.598,6652.73389,2.840,
5574.25342,128.598,6652.82520,3.840,
5574.34473,127.598,6652.91650,2.840,
5574.43652,127.598,6653.00830,3.840,
5574.52783,127.598,6653.09961,2.840,
5574.61963,127.598,6653.19141,2.840,
5574.71094,127.598,6653.28271,3.840,
5574.80225,127.598,6653.37451,3.840,
5574.89404,127.598,6653.46582,3.840,
5574.98535,127.598,6653.55713,3.840,
5575.07715,127.598,6653.64893,3.840,
5575.16846,126.598,6653.74023,3.840,
5575.26025,126.598,6653.83203,3.840,
5575.35156,127.598,6653.92334,3.840,
5575.44336,127.598,6654.01514,3.840,
5575.53467,127.598,6654.10645,3.840,
5575.62598,127.598,6654.19824,3.840,
5575.71777,127.598,6654.28955,3.840,
5575.80908,127.598,6654.38086,3.840,
5575.90088,127.598,6654.47266,3.840,
5575.99219,127.598,6654.56396,3.840,
5576.08398,126.598,6654.65576,3.840,
5576.17529,126.598,6654.74707,3.840,
5576.26660,127.598,6654.83887,4.840,
5576.35840,126.598,6654.93018,3.840,
5576.44971,126.598,6655.02148,3.840,
5576.54150,127.598,6655.11328,3.840,
5576.63281,126.598,6655.20459,3.840,
5576.72461,126.598,6655.29639,3.840,
5576.81592,126.598,6655.38770,3.840,
5576.90723,126.598,6655.47949,3.840,
5576.99902,125.598,6655.57080,2.840,
5577.09033,126.598,6655.66211,2.840,
5577.18213,126.598,6655.75391,3.840,
5577.27344,125.598,6655.84521,3.840,
5577.36523,125.598,6655.93701,3.840,
5577.45654,126.598,6656.02832,3.840,
5577.54834,125.598,6656.12012,2.840,
5577.63965,125.598,6656.21143,2.840,
5577.73096,126.598,6656.30322,3.840,
5577.82275,126.598,6656.39453,2.840,
5577.91406,125.598,6656.48584,2.840,
5578.00586,125.598,6656.57764,3.840,
5578.09717,125.598,6656.66895,3.840,
5578.18896,125.598,6656.76074,3.840,
5578.28027,125.598,6656.85205,2.840,
5578.37158,124.598,6656.94385,3.840,
5578.46338,125.598,6657.03516,3.840,
5578.55469,125.598,6657.12646,2.840,
5578.64648,125.598,6657.21826,2.840,
5578.73779,125.598,6657.30957,2.840,
5578.82959,125.598,6657.40137,2.840,
5578.92090,124.598,6657.49268,3.840,
5579.01221,125.598,6657.58447,3.840,
5579.10400,125.598,6657.67578,2.840,
5579.19531,124.598,6657.76709,3.840,
5579.28711,124.598,6657.85889,2.840,
5579.37842,124.598,6657.95020,3.840,
5579.47021,124.598,6658.04199,2.840,
5579.56152,124.598,6658.13330,2.840,
5579.65332,124.598,6658.22510,3.840,
5579.74463,124.598,6658.31641,3.840,
5579.83594,124.598,6658.40820,2.840,
5579.92773,124.598,6658.49951,3.840,
5580.01904,125.598,6658.59082,3.840,
5580.11084,124.598,6658.68262,3.840,
5580.20215,124.598,6658.77393,2.840,
5580.29395,123.598,6658.86572,3.840,
5580.38525,124.598,6658.95703,2.840,
5580.47656,124.598,6659.04883,3.840,
5580.56836,124.598,6659.14014,3.840,
5580.65967,124.598,6659.23145,3.840,
5580.75146,124.598,6659.32324,3.840,
5580.84277,124.598,6659.41455,3.840,
5580.93457,124.598,6659.50635,3.840,
5581.02588,123.598,6659.59766,3.840,
5581.11719,123.598,6659.68945,3.840,
5581.20898,123.598,6659.78076,3.840,
5581.30029,123.598,6659.87207,3.840,
5581.39209,123.598,6659.96387,3.840,
5581.48340,124.598,6660.05518,3.840,
5581.57520,124.598,6660.14697,3.840,
5581.66650,123.598,6660.23828,3.840,
5581.75781,123.598,6660.33008,3.840,
5581.84961,123.598,6660.42139,3.840,
5581.94092,123.598,6660.51318,3.840,
5582.03271,123.598,6660.60449,2.840,
5582.12402,123.598,6660.69580,3.840,
5582.21582,123.598,6660.78760,3.840,
5582.30713,122.598,6660.87891,3.840,
5582.39893,122.598,6660.97070,3.840,
5582.49023,122.598,6661.06201,3.840,
5582.58154,122.598,6661.15381,3.840,
5582.67334,123.598,6661.24512,3.840,
5582.76465,123.598,6661.33643,3.840,
5582.85645,122.598,6661.42822,3.840,
5582.94775,123.598,6661.51953,3.840,
5583.03955,122.598,6661.61133,3.840,
5583.13086,122.598,6661.70264,3.840,
5583.22217,122.598,6661.79443,3.840,
5583.31396,122.598,6661.88574,3.840,
5583.40527,122.598,6661.97705,3.840,
5583.49707,122.598,6662.06885,2.840,
5583.58838,122.598,6662.16016,3.840,
5583.68018,122.598,6662.25195,3.840,
5583.77148,122.598,6662.34326,3.840,
5583.86279,122.598,6662.43506,3.840,
5583.95459,122.598,6662.52637,3.840,
5584.04590,121.598,6662.61816,2.840,
5584.13770,121.598,6662.70947,3.840,
5584.22900,122.598,6662.80078,3.840,
5584.32080,121.598,6662.89258,3.840,
5584.41211,122.598,6662.98389,3.840,
5584.50391,122.598,6663.07568,3.840,
5584.59521,122.598,6663.16699,3.840,
5584.68652,121.598,6663.25879,3.840,
5584.77832,121.598,6663.35010,3.840,
5584.86963,121.598,6663.44141,3.840,
5584.96143,121.598,6663.53320,3.840,
5585.05273,121.598,6663.62451,4.840,
5585.14453,121.598,6663.71631,4.840,
5585.23584,121.598,6663.80762,4.840,
5585.32715,121.598,6663.89941,5.840,
5585.41895,120.598,6663.99072,6.840,
5585.51025,120.598,6664.08203,6.840,
5585.60205,121.598,6664.17383,6.840,
5585.69336,120.598,6664.26514,6.840,
5585.78516,121.598,6664.35693,6.840,
5585.87646,121.598,6664.44824,5.840,
5585.96777,120.598,6664.54004,5.840,
5586.05957,121.598,6664.63135,5.840,
5586.15088,120.598,6664.72314,4.840,
5586.24268,120.598,6664.81445,4.840,
5586.33398,121.598,6664.90576,4.840,
5586.42578,121.598,6664.99756,4.840,
5586.51709,120.598,6665.08887,4.840,
5586.60889,120.598,6665.18066,4.840,
5586.70020,120.598,6665.27197,4.840,
5586.79150,120.598,6665.36377,3.840,
5586.88330,120.598,6665.45508,3.840,
5586.97461,120.598,6665.54639,3.840,
5587.06641,120.598,6665.63818,3.840,
5587.15771,120.598,6665.72949,3.840,
5587.24951,120.598,6665.82129,3.840,
5587.34082,121.598,6665.91260,3.840,
5587.43213,120.598,6666.00439,2.840,
5587.52393,120.598,6666.09570,1.840,
5587.61523,120.598,6666.18701,1.840,
5587.70703,120.598,6666.27881,-0.160,
5587.79834,120.598,6666.37012,-1.160,
5587.89014,120.598,6666.46191,-1.160,
5587.98145,120.598,6666.55322,-0.160,
5588.07275,120.598,6666.64502,-1.160,
5588.16455,120.598,6666.73633,-1.160,
5588.25586,120.598,6666.82764,-0.160,
5588.34766,119.598,6666.91943,-0.160,
5588.43896,119.598,6667.01074,-0.160,
5588.53076,119.598,6667.10254,0.840,
5588.62207,119.598,6667.19385,0.840,
5588.71387,119.598,6667.28564,0.840,
5588.80518,120.598,6667.37695,1.840,
5588.89648,119.598,6667.46875,1.840,
5588.98828,118.598,6667.56006,1.840,
5589.07959,119.598,6667.65137,2.840,
5589.17139,119.598,6667.74316,1.840,
5589.26270,119.598,6667.83447,2.840,
5589.35449,119.598,6667.92627,2.840,
5589.44580,119.598,6668.01758,3.840,
5589.53711,118.598,6668.10938,2.840,
5589.62891,118.598,6668.20068,3.840,
5589.72021,118.598,6668.29199,3.840,
5589.81201,118.598,6668.38379,3.840,
5589.90332,117.598,6668.47510,3.840,
5589.99512,118.598,6668.56689,3.840,
5590.08643,118.598,6668.65820,3.840,
5590.17773,118.598,6668.75000,3.840,
5590.26953,119.598,6668.84131,3.840,
5590.36084,118.598,6668.93262,2.840,
5590.45264,118.598,6669.02441,3.840,
5590.54395,118.598,6669.11572,2.840,
5590.63574,118.598,6669.20752,2.840,
5590.72705,118.598,6669.29883,3.840,
5590.81885,118.598,6669.39063,2.840,
5590.91016,118.598,6669.48193,3.840,
5591.00146,118.598,6669.57373,3.840,
5591.09326,117.598,6669.66504,3.840,
5591.18457,118.598,6669.75635,3.840,
5591.27637,118.598,6669.84814,3.840,
5591.36768,117.598,6669.93945,3.840,
5591.45947,117.598,6670.03125,2.840,
5591.55078,117.598,6670.12256,3.840,
5591.64209,117.598,6670.21436,2.840,
5591.73389,118.598,6670.30566,3.840,
5591.82520,117.598,6670.39697,2.840,
5591.91699,117.598,6670.48877,2.840,
5592.00830,117.598,6670.58008,2.840,
5592.10010,117.598,6670.67188,3.840,
5592.19141,117.598,6670.76318,3.840,
5592.28271,117.598,6670.85498,3.840,
5592.37451,117.598,6670.94629,4.840,
5592.46582,117.598,6671.03760,3.840,
5592.55762,117.598,6671.12939,3.840,
5592.64893,117.598,6671.22070,2.840,
5592.74072,117.598,6671.31250,3.840,
5592.83203,117.598,6671.40381,3.840,
5592.92334,116.598,6671.49561,2.840,
5593.01514,116.598,6671.58691,3.840,
5593.10645,117.598,6671.67871,3.840,
5593.19824,117.598,6671.77002,3.840,
5593.28955,117.598,6671.86133,2.840,
5593.38135,117.598,6671.95313,2.840,
5593.47266,117.598,6672.04443,2.840,
5593.56445,116.598,6672.13623,3.840,
5593.65576,116.598,6672.22754,2.840,
5593.74707,116.598,6672.31934,3.840,
5593.83887,116.598,6672.41064,3.840,
5593.93018,116.598,6672.50195,2.840,
5594.02197,116.598,6672.59375,2.840,
5594.11328,116.598,6672.68506,3.840,
5594.20508,116.598,6672.77686,2.840,
5594.29639,116.598,6672.86816,3.840,
5594.38770,116.598,6672.95996,3.840,
5594.47949,116.598,6673.05127,3.840,
5594.57080,115.598,6673.14258,3.840,
5594.66260,116.598,6673.23438,3.840,
5594.75391,116.598,6673.32568,2.840,
5594.84570,115.598,6673.41748,2.840,
5594.93701,115.598,6673.50879,2.840,
5595.02832,116.598,6673.60059,2.840,
5595.12012,115.598,6673.69189,2.840,
5595.21143,115.598,6673.78369,3.840,
5595.30322,115.598,6673.87500,3.840,
5595.39453,115.598,6673.96631,3.840,
5595.48633,114.598,6674.05811,3.840,
5595.57764,115.598,6674.14941,2.840,
5595.66943,115.598,6674.24121,3.840,
5595.76074,114.598,6674.33252,3.840,
5595.85205,115.598,6674.42432,3.840,
5595.94385,115.598,6674.51563,3.840,
5596.03516,115.598,6674.60693,3.840,
5596.12695,115.598,6674.69873,2.840,
5596.21826,115.598,6674.79004,3.840,
5596.31006,115.598,6674.88184,3.840,
5596.40137,115.598,6674.97314,3.840,
5596.49268,115.598,6675.06494,3.840,
5596.58447,115.598,6675.15625,2.840,
5596.67578,115.598,6675.24756,2.840,
5596.76758,115.598,6675.33936,3.840,
5596.85889,114.598,6675.43066,3.840,
5596.95068,114.598,6675.52246,2.840,
5597.04199,114.598,6675.61377,2.840,
5597.13330,114.598,6675.70557,2.840,
5597.22510,114.598,6675.79688,2.840,
5597.31641,114.598,6675.88867,2.840,
5597.40820,114.598,6675.97998,3.840,
5597.49951,114.598,6676.07129,2.840,
5597.59131,115.598,6676.16309,2.840,
5597.68262,114.598,6676.25439,2.840,
5597.77441,114.598,6676.34619,2.840,
5597.86572,113.598,6676.43750,2.840,
5597.95703,114.598,6676.52930,2.840,
5598.04883,114.598,6676.62061,3.840,
5598.14014,113.598,6676.71191,2.840,
5598.23193,113.598,6676.80371,2.840,
5598.32324,114.598,6676.89502,3.840,
5598.41504,113.598,6676.98682,2.840,
5598.50635,113.598,6677.07813,2.840,
5598.59766,113.598,6677.16992,2.840,
5598.68945,113.598,6677.26123,3.840,
5598.78076,113.598,6677.35254,2.840,
5598.87256,113.598,6677.44434,3.840,
5598.96387,113.598,6677.53564,2.840,
5599.05566,113.598,6677.62744,2.840,
5599.14697,113.598,6677.71875,2.840,
5599.23828,113.598,6677.81055,3.840,
5599.33008,113.598,6677.90186,2.840,
5599.42139,113.598,6677.99316,2.840,
5599.51318,113.598,6678.08496,3.840,
5599.60449,113.598,6678.17627,2.840,
5599.69629,112.598,6678.26807,3.840,
5599.78760,112.598,6678.35938,3.840,
5599.87939,112.598,6678.45117,3.840,
5599.97070,112.598,6678.54248,2.840,
5600.06201,112.598,6678.63428,3.840,
5600.15381,113.598,6678.72559,2.840,
5600.24512,112.598,6678.81689,3.840,
5600.33691,112.598,6678.90869,2.840,
5600.42822,112.598,6679.00000,3.840,
5600.52002,112.598,6679.09180,2.840,
5600.61133,112.598,6679.18311,2.840,
5600.70264,112.598,6679.27490,2.840,
5600.79443,111.598,6679.36621,3.840,
5600.88574,111.598,6679.45752,2.840,
5600.97754,111.598,6679.54932,2.840,
5601.06885,112.598,6679.64063,3.840,
5601.16064,112.598,6679.73242,3.840,
5601.25195,111.598,6679.82373,2.840,
5601.34326,112.598,6679.91553,3.840,
5601.43506,112.598,6680.00684,3.840,
5601.52637,111.598,6680.09814,3.840,
5601.61816,111.598,6680.18994,3.840,
5601.70947,111.598,6680.28125,3.840,
5601.80127,111.598,6680.37305,3.840,
5601.89258,111.598,6680.46436,2.840,
5601.98438,112.598,6680.55615,2.840,
5602.07568,111.598,6680.64746,2.840,
5602.16699,111.598,6680.73926,2.840,
5602.25879,111.598,6680.83057,2.840,
5602.35010,111.598,6680.92188,2.840,
5602.44189,111.598,6681.01367,2.840,
5602.53320,111.598,6681.10498,3.840,
5602.62500,111.598,6681.19678,3.840,
5602.71631,111.598,6681.28809,3.840,
5602.80762,110.598,6681.37988,2.840,
5602.89941,110.598,6681.47119,2.840,
5602.99072,110.598,6681.56250,2.840,
5603.08252,110.598,6681.65430,2.840,
5603.17383,111.598,6681.74561,1.840,
5603.26563,110.598,6681.83740,1.840,
5603.35693,110.598,6681.92871,1.840,
5603.44824,111.598,6682.02051,1.840,
5603.54004,111.598,6682.11182,1.840,
5603.63135,110.598,6682.20313,0.840,
5603.72314,110.598,6682.29492,1.840,
5603.81445,110.598,6682.38623,1.840,
5603.90625,110.598,6682.47803,1.840,
5603.99756,110.598,6682.56934,1.840,
5604.08936,110.598,6682.66113,2.840,
5604.18066,110.598,6682.75244,2.840,
5604.27197,110.598,6682.84424,2.840,
5604.36377,110.598,6682.93555,2.840,
5604.45508,110.598,6683.02686,3.840,
5604.54688,110.598,6683.11865,2.840,
5604.63818,110.598,6683.20996,2.840,
5604.72998,110.598,6683.30176,2.840,
5604.82129,110.598,6683.39307,2.840,
5604.91260,110.598,6683.48486,2.840,
5605.00439,110.598,6683.57617,2.840,
5605.09570,110.598,6683.66748,2.840,
5605.18750,110.598,6683.75928,2.840,
5605.27881,109.598,6683.85059,2.840,
5605.37061,110.598,6683.94238,3.840,
5605.46191,109.598,6684.03369,3.840,
5605.55322,109.598,6684.12549,4.840,
5605.64502,110.598,6684.21680,4.840,
5605.73633,109.598,6684.30811,5.840,
5605.82813,109.598,6684.39990,4.840,
5605.91943,109.598,6684.49121,5.840,
5606.01123,109.598,6684.58301,5.840,
5606.10254,109.598,6684.67432,5.840,
5606.19385,109.598,6684.76611,5.840,
5606.28564,109.598,6684.85742,5.840,
5606.37695,110.598,6684.94922,4.840,
5606.46875,108.598,6685.04053,4.840,
5606.56006,109.598,6685.13184,4.840,
5606.65186,108.598,6685.22363,4.840,
5606.74316,108.598,6685.31494,3.840,
5606.83496,108.598,6685.40674,3.840,
5606.92627,108.598,6685.49805,3.840,
5607.01758,108.598,6685.58984,3.840,
5607.10938,108.598,6685.68115,3.840,
5607.20068,107.598,6685.77246,3.840,
5607.29248,108.598,6685.86426,3.840,
5607.38379,107.598,6685.95557,2.840,
5607.47559,107.598,6686.04736,2.840,
5607.56689,108.598,6686.13867,3.840,
5607.65820,108.598,6686.23047,2.840,
5607.75000,108.598,6686.32178,3.840,
5607.84131,108.598,6686.41309,3.840,
5607.93311,108.598,6686.50488,2.840,
5608.02441,107.598,6686.59619,2.840,
5608.11621,107.598,6686.68799,2.840,
5608.20752,107.598,6686.77930,3.840,
5608.29883,107.598,6686.87109,2.840,
5608.39063,107.598,6686.96240,2.840,
5608.48193,108.598,6687.05420,3.840,
5608.57373,107.598,6687.14551,2.840,
5608.66504,107.598,6687.23682,2.840,
5608.75684,108.598,6687.32861,2.840,
5608.84814,108.598,6687.41992,2.840,
5608.93994,107.598,6687.51172,2.840,
5609.03125,107.598,6687.60303,2.840,
5609.12256,107.598,6687.69482,2.840,
5609.21436,107.598,6687.78613,2.840,
5609.30566,107.598,6687.87744,2.840,
5609.39746,107.598,6687.96924,2.840,
5609.48877,107.598,6688.06055,2.840,
5609.58057,106.598,6688.15234,2.840,
5609.67188,106.598,6688.24365,3.840,
5609.76318,106.598,6688.33545,2.840,
5609.85498,106.598,6688.42676,2.840,
5609.94629,107.598,6688.51807,3.840,
5610.03809,107.598,6688.60986,2.840,
5610.12939,106.598,6688.70117,3.840,
5610.22119,106.598,6688.79297,2.840,
5610.31250,107.598,6688.88428,3.840,
5610.40381,106.598,6688.97607,2.840,
5610.49561,106.598,6689.06738,2.840,
5610.58691,106.598,6689.15918,3.840,
5610.67871,106.598,6689.25049,2.840,
5610.77002,107.598,6689.34180,2.840,
5610.86182,106.598,6689.43359,2.840,
5610.95313,106.598,6689.52490,2.840,
5611.04492,106.598,6689.61670,2.840,
5611.13623,106.598,6689.70801,2.840,
5611.22754,106.598,6689.79980,2.840,
5611.31934,106.598,6689.89111,2.840,
5611.41064,106.598,6689.98242,2.840,
5611.50244,105.598,6690.07422,2.840,
5611.59375,106.598,6690.16553,2.840,
5611.68555,105.598,6690.25732,2.840,
5611.77686,106.598,6690.34863,2.840,
5611.86816,106.598,6690.44043,2.840,
5611.95996,105.598,6690.53174,2.840,
5612.05127,105.598,6690.62305,3.840,
5612.14307,106.598,6690.71484,3.840,
5612.23438,106.598,6690.80615,2.840,
5612.32617,105.598,6690.89795,2.840,
5612.41748,106.598,6690.98926,2.840,
5612.50879,105.598,6691.08105,2.840,
5612.60059,105.598,6691.17236,2.840,
5612.69189,105.598,6691.26367,2.840,
5612.78369,106.598,6691.35547,2.840,
5612.87500,105.598,6691.44678,2.840,
5612.96680,105.598,6691.53857,2.840,
5613.05811,105.598,6691.62988,3.840,
5613.14990,105.598,6691.72168,2.840,
5613.24121,104.598,6691.81299,2.840,
5613.33252,105.598,6691.90479,2.840,
5613.42432,104.598,6691.99609,2.840,
5613.51563,105.598,6692.08740,2.840,
5613.60742,105.598,6692.17920,2.840,
5613.69873,105.598,6692.27051,1.840,
5613.79053,105.598,6692.36230,2.840,
5613.88184,105.598,6692.45361,2.840,
5613.97314,105.598,6692.54541,2.840,
5614.06494,105.598,6692.63672,2.840,
5614.15625,105.598,6692.72803,2.840,
5614.24805,105.598,6692.81982,3.840,
5614.33936,105.598,6692.91113,3.840,
5614.43115,104.598,6693.00293,2.840,
5614.52246,104.598,6693.09424,2.840,
5614.61377,104.598,6693.18604,2.840,
5614.70557,104.598,6693.27734,2.840,
5614.79688,104.598,6693.36865,2.840,
5614.88867,104.598,6693.46045,2.840,
5614.97998,104.598,6693.55176,2.840,
5615.07178,104.598,6693.64355,2.840,
5615.16309,104.598,6693.73486,2.840,
5615.25488,104.598,6693.82666,2.840,
5615.34619,104.598,6693.91797,2.840,
5615.43750,103.598,6694.00977,2.840,
5615.52930,104.598,6694.10107,3.840,
5615.62061,103.598,6694.19238,2.840,
5615.71240,104.598,6694.28418,2.840,
5615.80371,104.598,6694.37549,3.840,
5615.89551,104.598,6694.46729,3.840,
5615.98682,103.598,6694.55859,2.840,
5616.07813,103.598,6694.65039,3.840,
5616.16992,103.598,6694.74170,3.840,
5616.26123,103.598,6694.83301,2.840,
5616.35303,103.598,6694.92480,2.840,
5616.44434,103.598,6695.01611,3.840,
5616.53613,103.598,6695.10791,2.840,
5616.62744,104.598,6695.19922,2.840,
5616.71875,103.598,6695.29102,2.840,
5616.81055,103.598,6695.38232,3.840,
5616.90186,102.598,6695.47363,2.840,
5616.99365,103.598,6695.56543,2.840,
5617.08496,103.598,6695.65674,2.840,
5617.17676,103.598,6695.74854,2.840,
5617.26807,103.598,6695.83984,3.840,
5617.35986,103.598,6695.93164,2.840,
5617.45117,103.598,6696.02295,3.840,
5617.54248,103.598,6696.11475,2.840,
5617.63428,102.598,6696.20605,2.840,
5617.72559,102.598,6696.29736,2.840,
5617.81738,102.598,6696.38916,2.840,
5617.90869,102.598,6696.48047,2.840,
5618.00049,102.598,6696.57227,2.840,
5618.09180,102.598,6696.66357,2.840,
5618.18311,102.598,6696.75537,2.840,
5618.27490,102.598,6696.84668,2.840,
5618.36621,102.598,6696.93799,2.840,
5618.45801,102.598,6697.02979,2.840,
5618.54932,102.598,6697.12109,2.840,
5618.64111,102.598,6697.21289,2.840,
5618.73242,101.598,6697.30420,2.840,
5618.82373,101.598,6697.39600,2.840,
5618.91553,102.598,6697.48730,2.840,
5619.00684,101.598,6697.57861,2.840,
5619.09863,101.598,6697.67041,2.840,
5619.18994,102.598,6697.76172,2.840,
5619.28174,102.598,6697.85352,2.840,
5619.37305,101.598,6697.94482,2.840,
5619.46436,101.598,6698.03662,2.840,
5619.55615,102.598,6698.12793,2.840,
5619.64746,102.598,6698.21973,2.840,
5619.73926,101.598,6698.31104,2.840,
5619.83057,102.598,6698.40234,3.840,
5619.92236,101.598,6698.49414,1.840,
5620.01367,101.598,6698.58545,2.840,
5620.10547,102.598,6698.67725,2.840,
5620.19678,101.598,6698.76855,3.840,
5620.28809,101.598,6698.86035,2.840,
5620.37988,101.598,6698.95166,1.840,
5620.47119,101.598,6699.04297,1.840,
5620.56299,101.598,6699.13477,1.840,
5620.65430,101.598,6699.22607,0.840,
5620.74609,101.598,6699.31787,1.840,
5620.83740,101.598,6699.40918,0.840,
5620.92871,100.598,6699.50098,1.840,
5621.02051,101.598,6699.59229,1.840,
5621.11182,101.598,6699.68359,1.840,
5621.20361,101.598,6699.77539,1.840,
5621.29492,101.598,6699.86670,1.840,
5621.38672,101.598,6699.95850,2.840,
5621.47803,100.598,6700.04980,2.840,
5621.56934,100.598,6700.14160,2.840,
5621.66113,100.598,6700.23291,3.840,
5621.75244,100.598,6700.32471,3.840,
5621.84424,100.598,6700.41602,3.840,
5621.93555,100.598,6700.50732,3.840,
5622.02734,100.598,6700.59912,3.840,
5622.11865,100.598,6700.69043,3.840,
5622.21045,100.598,6700.78223,2.840,
5622.30176,100.598,6700.87354,2.840,
5622.39307,99.598,6700.96533,2.840,
5622.48486,101.598,6701.05664,2.840,
5622.57617,100.598,6701.14795,3.840,
5622.66797,100.598,6701.23975,2.840,
5622.75928,100.598,6701.33105,2.840,
5622.85107,100.598,6701.42285,2.840,
5622.94238,100.598,6701.51416,2.840,
5623.03369,100.598,6701.60596,2.840,
5623.12549,100.598,6701.69727,2.840,
5623.21680,100.598,6701.78857,2.840,
5623.30859,100.598,6701.88037,2.840,
5623.39990,99.598,6701.97168,2.840,
5623.49170,100.598,6702.06348,1.840,
5623.58301,99.598,6702.15479,1.840,
5623.67432,100.598,6702.24658,1.840,
5623.76611,99.598,6702.33789,1.840,
5623.85742,99.598,6702.42969,1.840,
5623.94922,99.598,6702.52100,1.840,
5624.04053,99.598,6702.61230,1.840,
5624.13232,99.598,6702.70410,1.840,
5624.22363,99.598,6702.79541,1.840,
5624.31543,99.598,6702.88721,1.840,
5624.40674,99.598,6702.97852,1.840,
5624.49805,99.598,6703.07031,2.840,
5624.58984,99.598,6703.16162,2.840,
5624.68115,99.598,6703.25293,2.840,
5624.77295,99.598,6703.34473,2.840,
5624.86426,99.598,6703.43604,2.840,
5624.95605,99.598,6703.52783,2.840,
5625.04736,99.598,6703.61914,1.840,
5625.13867,99.598,6703.71094,2.840,
5625.23047,99.598,6703.80225,2.840,
5625.32178,99.598,6703.89355,2.840,
5625.41357,100.598,6703.98535,2.840,
5625.50488,99.598,6704.07666,2.840,
5625.59668,100.598,6704.16846,2.840,
5625.68799,99.598,6704.25977,2.840,
5625.77930,99.598,6704.35156,2.840,
5625.87109,100.598,6704.44287,2.840,
5625.96240,99.598,6704.53418,2.840,
5626.05420,99.598,6704.62598,2.840,
5626.14551,99.598,6704.71729,2.840,
5626.23730,99.598,6704.80908,2.840,
5626.32861,99.598,6704.90039,2.840,
5626.42041,99.598,6704.99219,2.840,
5626.51172,99.598,6705.08350,2.840,
5626.60303,99.598,6705.17529,2.840,
5626.69482,98.598,6705.26660,2.840,
5626.78613,99.598,6705.35791,2.840,
5626.87793,99.598,6705.44971,2.840,
5626.96924,98.598,6705.54102,2.840,
5627.06104,98.598,6705.63281,2.840,
5627.15234,98.598,6705.72412,2.840,
5627.24365,98.598,6705.81592,2.840,
5627.33545,98.598,6705.90723,2.840,
5627.42676,98.598,6705.99854,2.840,
5627.51855,98.598,6706.09033,2.840,
5627.60986,98.598,6706.18164,2.840,
5627.70166,98.598,6706.27344,2.840,
5627.79297,99.598,6706.36475,2.840,
5627.88428,98.598,6706.45654,2.840,
5627.97607,98.598,6706.54785,2.840,
5628.06738,98.598,6706.63916,2.840,
5628.15918,98.598,6706.73096,2.840,
5628.25049,98.598,6706.82227,2.840,
5628.34229,99.598,6706.91406,2.840,
5628.43359,98.598,6707.00537,1.840,
5628.52539,98.598,6707.09717,1.840,
5628.61670,98.598,6707.18848,1.840,
5628.70801,98.598,6707.28027,2.840,
5628.79980,97.598,6707.37158,1.840,
5628.89111,97.598,6707.46289,1.840,
5628.98291,97.598,6707.55469,2.840,
5629.07422,97.598,6707.64600,2.840,
5629.16602,97.598,6707.73779,2.840,
5629.25732,96.598,6707.82910,1.840,
5629.34863,97.598,6707.92090,1.840,
5629.44043,97.598,6708.01221,2.840,
5629.53174,97.598,6708.10352,1.840,
5629.62354,97.598,6708.19531,2.840,
5629.71484,97.598,6708.28662,2.840,
5629.80664,97.598,6708.37842,2.840,
5629.89795,97.598,6708.46973,2.840,
5629.98926,96.598,6708.56152,2.840,
5630.08105,97.598,6708.65283,2.840,
5630.17236,97.598,6708.74414,2.840,
5630.26416,97.598,6708.83594,2.840,
5630.35547,96.598,6708.92725,2.840,
5630.44727,97.598,6709.01904,2.840,
5630.53857,97.598,6709.11035,2.840,
5630.62988,96.598,6709.20215,2.840,
5630.72168,96.598,6709.29346,2.840,
5630.81299,96.598,6709.38525,2.840,
5630.90479,96.598,6709.47656,1.840,
5630.99609,96.598,6709.56787,1.840,
5631.08789,96.598,6709.65967,2.840,
5631.17920,96.598,6709.75098,2.840,
5631.27100,96.598,6709.84277,1.840,
5631.36230,96.598,6709.93408,2.840,
5631.45361,96.598,6710.02588,2.840,
5631.54541,96.598,6710.11719,1.840,
5631.63672,96.598,6710.20850,1.840,
5631.72852,96.598,6710.30029,2.840,
5631.81982,96.598,6710.39160,2.840,
5631.91162,96.598,6710.48340,2.840,
5632.00293,96.598,6710.57471,1.840,
5632.09424,96.598,6710.66650,2.840,
5632.18604,95.598,6710.75781,1.840,
5632.27734,95.598,6710.84912,1.840,
5632.36914,95.598,6710.94092,2.840,
5632.46045,95.598,6711.03223,2.840,
5632.55225,95.598,6711.12402,1.840,
5632.64355,95.598,6711.21533,1.840,
5632.73486,96.598,6711.30713,2.840,
5632.82666,95.598,6711.39844,1.840,
5632.91797,96.598,6711.49023,1.840,
5633.00977,95.598,6711.58154,2.840,
5633.10107,95.598,6711.67285,1.840,
5633.19287,95.598,6711.76465,1.840,
5633.28418,95.598,6711.85596,1.840,
5633.37598,94.598,6711.94775,2.840,
5633.46729,95.598,6712.03906,1.840,
5633.55859,95.598,6712.13086,1.840,
5633.65039,94.598,6712.22217,2.840,
5633.74170,94.598,6712.31348,1.840,
5633.83350,94.598,6712.40527,1.840,
5633.92480,94.598,6712.49658,1.840,
5634.01660,95.598,6712.58838,1.840,
5634.10791,94.598,6712.67969,1.840,
5634.19922,95.598,6712.77148,1.840,
5634.29102,94.598,6712.86279,1.840,
5634.38232,94.598,6712.95410,1.840,
5634.47412,94.598,6713.04590,1.840,
5634.56543,94.598,6713.13721,1.840,
5634.65723,94.598,6713.22900,1.840,
5634.74854,95.598,6713.32031,1.840,
5634.83984,94.598,6713.41211,2.840,
5634.93164,94.598,6713.50342,2.840,
5635.02295,95.598,6713.59521,1.840,
5635.11475,95.598,6713.68652,2.840,
5635.20605,94.598,6713.77783,1.840,
5635.29785,94.598,6713.86963,1.840,
5635.38916,94.598,6713.96094,1.840,
5635.48096,94.598,6714.05273,1.840,
5635.57227,94.598,6714.14404,1.840,
5635.66357,95.598,6714.23584,1.840,
5635.75537,94.598,6714.32715,1.840,
5635.84668,94.598,6714.41846,1.840,
5635.93848,94.598,6714.51025,2.840,
5636.02979,94.598,6714.60156,1.840,
5636.12158,94.598,6714.69336,1.840,
5636.21289,94.598,6714.78467,1.840,
5636.30420,94.598,6714.87646,2.840,
5636.39600,94.598,6714.96777,1.840,
5636.48730,93.598,6715.05908,1.840,
5636.57910,94.598,6715.15088,1.840,
5636.67041,94.598,6715.24219,2.840,
5636.76221,93.598,6715.33398,1.840,
5636.85352,93.598,6715.42529,1.840,
5636.94482,94.598,6715.51709,2.840,
5637.03662,93.598,6715.60840,1.840,
5637.12793,93.598,6715.69971,1.840,
5637.21973,94.598,6715.79150,1.840,
5637.31104,93.598,6715.88281,1.840,
5637.40283,94.598,6715.97461,1.840,
5637.49414,93.598,6716.06592,1.840,
5637.58594,93.598,6716.15771,2.840,
5637.67725,93.598,6716.24902,1.840,
5637.76855,93.598,6716.34082,1.840,
5637.86035,93.598,6716.43213,1.840,
5637.95166,93.598,6716.52344,2.840,
5638.04346,93.598,6716.61523,1.840,
5638.13477,93.598,6716.70654,1.840,
5638.22656,93.598,6716.79834,0.840,
5638.31787,92.598,6716.88965,0.840,
5638.40918,93.598,6716.98145,-0.160,
5638.50098,93.598,6717.07275,0.840,
5638.59229,93.598,6717.16406,0.840,
5638.68408,93.598,6717.25586,-0.160,
5638.77539,93.598,6717.34717,0.840,
5638.86719,93.598,6717.43896,0.840,
5638.95850,92.598,6717.53027,0.840,
5639.04980,93.598,6717.62207,0.840,
5639.14160,93.598,6717.71338,1.840,
5639.23291,93.598,6717.80469,1.840,
5639.32471,92.598,6717.89648,1.840,
5639.41602,93.598,6717.98779,1.840,
5639.50781,92.598,6718.07959,1.840,
5639.59912,92.598,6718.17090,1.840,
5639.69092,92.598,6718.26270,1.840,
5639.78223,92.598,6718.35400,1.840,
5639.87354,92.598,6718.44580,1.840,
5639.96533,92.598,6718.53711,1.840,
5640.05664,93.598,6718.62842,1.840,
5640.14844,92.598,6718.72021,1.840,
5640.23975,92.598,6718.81152,1.840,
5640.33154,92.598,6718.90332,1.840,
5640.42285,92.598,6718.99463,1.840,
5640.51416,92.598,6719.08643,1.840,
5640.60596,92.598,6719.17773,1.840,
5640.69727,92.598,6719.26904,1.840,
5640.78906,91.598,6719.36084,1.840,
5640.88037,92.598,6719.45215,2.840,
5640.97217,92.598,6719.54395,2.840,
5641.06348,92.598,6719.63525,2.840,
5641.15479,91.598,6719.72705,3.840,
5641.24658,92.598,6719.81836,2.840,
5641.33789,92.598,6719.90967,3.840,
5641.42969,91.598,6720.00146,3.840,
5641.52100,92.598,6720.09277,2.840,
5641.61279,91.598,6720.18457,3.840,
5641.70410,91.598,6720.27588,2.840,
5641.79590,92.598,6720.36768,2.840,
5641.88721,91.598,6720.45898,2.840,
5641.97852,91.598,6720.55078,2.840,
5642.07031,91.598,6720.64209,2.840,
5642.16162,92.598,6720.73340,2.840,
5642.25342,91.598,6720.82520,2.840,
5642.34473,91.598,6720.91650,2.840,
5642.43652,91.598,6721.00830,1.840,
5642.52783,91.598,6721.09961,1.840,
5642.61914,91.598,6721.19141,1.840,
5642.71094,91.598,6721.28271,1.840,
5642.80225,91.598,6721.37402,1.840,
5642.89404,91.598,6721.46582,1.840,
5642.98535,92.598,6721.55713,1.840,
5643.07715,91.598,6721.64893,1.840,
5643.16846,91.598,6721.74023,1.840,
5643.25977,91.598,6721.83203,1.840,
5643.35156,91.598,6721.92334,2.840,
5643.44287,91.598,6722.01465,1.840,
5643.53467,90.598,6722.10645,1.840,
5643.62598,91.598,6722.19775,1.840,
5643.71777,91.598,6722.28955,2.840,
5643.80908,90.598,6722.38086,1.840,
5643.90039,90.598,6722.47266,1.840,
5643.99219,90.598,6722.56396,2.840,
5644.08350,91.598,6722.65576,2.840,
5644.17529,90.598,6722.74707,1.840,
5644.26660,91.598,6722.83838,1.840,
5644.35840,91.598,6722.93018,2.840,
5644.44971,90.598,6723.02148,1.840,
5644.54150,91.598,6723.11328,1.840,
5644.63281,90.598,6723.20459,1.840,
5644.72412,90.598,6723.29639,1.840,
5644.81592,90.598,6723.38770,1.840,
5644.90723,90.598,6723.47900,1.840,
5644.99902,89.598,6723.57080,1.840,
5645.09033,90.598,6723.66211,1.840,
5645.18213,90.598,6723.75391,1.840,
5645.27344,90.598,6723.84521,1.840,
5645.36475,89.598,6723.93701,1.840,
5645.45654,90.598,6724.02832,1.840,
5645.54785,90.598,6724.11963,1.840,
5645.63965,90.598,6724.21143,0.840,
5645.73096,90.598,6724.30273,1.840,
5645.82275,90.598,6724.39453,1.840,
5645.91406,90.598,6724.48584,1.840,
5646.00537,90.598,6724.57764,1.840,
5646.09717,89.598,6724.66895,1.840,
5646.18848,90.598,6724.76074,2.840,
5646.28027,89.598,6724.85205,1.840,
5646.37158,90.598,6724.94336,1.840,
5646.46338,90.598,6725.03516,1.840,
5646.55469,90.598,6725.12646,1.840,
5646.64648,89.598,6725.21826,1.840,
5646.73779,90.598,6725.30957,1.840,
5646.82910,89.598,6725.40137,1.840,
5646.92090,89.598,6725.49268,1.840,
5647.01221,89.598,6725.58398,1.840,
5647.10400,89.598,6725.67578,1.840,
5647.19531,89.598,6725.76709,2.840,
5647.28711,88.598,6725.85889,1.840,
5647.37842,89.598,6725.95020,1.840,
5647.46973,88.598,6726.04199,1.840,
5647.56152,88.598,6726.13330,1.840,
5647.65283,89.598,6726.22461,1.840,
5647.74463,88.598,6726.31641,1.840,
5647.83594,88.598,6726.40771,1.840,
5647.92773,88.598,6726.49951,1.840,
5648.01904,88.598,6726.59082,1.840,
5648.11035,88.598,6726.68262,1.840,
5648.20215,88.598,6726.77393,1.840,
5648.29346,88.598,6726.86572,1.840,
5648.38525,88.598,6726.95703,1.840,
5648.47656,88.598,6727.04834,1.840,
5648.56836,88.598,6727.14014,1.840,
5648.65967,88.598,6727.23145,1.840,
5648.75146,88.598,6727.32324,1.840,
5648.84277,89.598,6727.41455,1.840,
5648.93408,89.598,6727.50635,1.840,
5649.02588,88.598,6727.59766,0.840,
5649.11719,88.598,6727.68896,1.840,
5649.20898,88.598,6727.78076,1.840,
5649.30029,87.598,6727.87207,1.840,
5649.39209,87.598,6727.96387,1.840,
5649.48340,88.598,6728.05518,1.840,
5649.57471,88.598,6728.14697,1.840,
5649.66650,87.598,6728.23828,1.840,
5649.75781,87.598,6728.32959,1.840,
5649.84961,88.598,6728.42139,1.840,
5649.94092,87.598,6728.51270,1.840,
5650.03271,88.598,6728.60449,1.840,
5650.12402,88.598,6728.69580,1.840,
5650.21533,88.598,6728.78760,1.840,
5650.30713,88.598,6728.87891,0.840,
5650.39844,87.598,6728.97021,1.840,
5650.49023,87.598,6729.06201,1.840,
5650.58154,88.598,6729.15332,1.840,
5650.67334,88.598,6729.24512,0.840,
5650.76465,88.598,6729.33643,1.840,
5650.85645,88.598,6729.42822,1.840,
5650.94775,87.598,6729.51953,1.840,
5651.03906,88.598,6729.61133,0.840,
5651.13086,88.598,6729.70264,0.840,
5651.22217,87.598,6729.79395,1.840,
5651.31396,88.598,6729.88574,0.840,
5651.40527,88.598,6729.97705,1.840,
5651.49707,87.598,6730.06885,1.840,
5651.58838,87.598,6730.16016,1.840,
5651.67969,87.598,6730.25195,0.840,
5651.77148,87.598,6730.34326,1.840,
5651.86279,87.598,6730.43457,1.840,
5651.95459,87.598,6730.52637,0.840,
5652.04590,87.598,6730.61768,1.840,
5652.13770,87.598,6730.70947,0.840,
5652.22900,87.598,6730.80078,0.840,
5652.32031,87.598,6730.89258,1.840,
5652.41211,87.598,6730.98389,1.840,
5652.50342,87.598,6731.07520,0.840,
5652.59521,86.598,6731.16699,0.840,
5652.68652,86.598,6731.25830,1.840,
5652.77832,86.598,6731.35010,1.840,
5652.86963,86.598,6731.44141,1.840,
5652.96143,86.598,6731.53320,1.840,
5653.05273,86.598,6731.62451,0.840,
5653.14404,86.598,6731.71631,1.840,
5653.23584,87.598,6731.80762,0.840,
5653.32715,86.598,6731.89893,0.840,
5653.41895,87.598,6731.99072,0.840,
5653.51025,86.598,6732.08203,1.840,
5653.60205,86.598,6732.17383,0.840,
5653.69336,86.598,6732.26514,1.840,
5653.78467,86.598,6732.35693,0.840,
5653.87646,87.598,6732.44824,1.840,
5653.96777,86.598,6732.53955,1.840,
5654.05957,86.598,6732.63135,1.840,
5654.15088,86.598,6732.72266,1.840,
5654.24268,85.598,6732.81445,0.840,
5654.33398,86.598,6732.90576,1.840,
5654.42529,86.598,6732.99756,1.840,
5654.51709,85.598,6733.08887,1.840,
5654.60840,86.598,6733.18018,0.840,
5654.70020,86.598,6733.27197,1.840,
5654.79150,86.598,6733.36328,0.840,
5654.88330,86.598,6733.45508,0.840,
5654.97461,86.598,6733.54639,0.840,
5655.06592,85.598,6733.63818,1.840,
5655.15771,86.598,6733.72949,0.840,
5655.24902,85.598,6733.82129,0.840,
5655.34082,86.598,6733.91260,1.840,
5655.43213,85.598,6734.00391,0.840,
5655.52393,85.598,6734.09570,0.840,
5655.61523,86.598,6734.18701,1.840,
5655.70703,85.598,6734.27881,0.840,
5655.79834,85.598,6734.37012,0.840,
5655.88965,85.598,6734.46191,0.840,
5655.98145,85.598,6734.55322,-0.160,
5656.07275,85.598,6734.64453,-0.160,
5656.16455,85.598,6734.73633,-2.160,
5656.25586,85.598,6734.82764,-2.160,
5656.34766,85.598,6734.91943,-2.160,
5656.43896,85.598,6735.01074,-2.160,
5656.53027,85.598,6735.10254,-2.160,
5656.62207,85.598,6735.19385,-2.160,
5656.71338,85.598,6735.28516,-1.160,
5656.80518,85.598,6735.37695,-1.160,
5656.89648,85.598,6735.46826,-1.160,
5656.98828,84.598,6735.56006,-0.160,
5657.07959,84.598,6735.65137,-1.160,
5657.17090,85.598,6735.74316,-0.160,
5657.26270,85.598,6735.83447,-0.160,
5657.35400,84.598,6735.92627,-0.160,
5657.44580,85.598,6736.01758,0.840,
5657.53711,85.598,6736.10889,0.840,
5657.62891,85.598,6736.20068,0.840,
5657.72021,85.598,6736.29199,0.840,
5657.81201,84.598,6736.38379,0.840,
5657.90332,85.598,6736.47510,0.840,
5657.99463,84.598,6736.56689,0.840,
5658.08643,85.598,6736.65820,0.840,
5658.17773,84.598,6736.74951,0.840,
5658.26953,84.598,6736.84131,1.840,
5658.36084,85.598,6736.93262,1.840,
5658.45264,84.598,6737.02441,2.840,
5658.54395,84.598,6737.11572,3.840,
5658.63525,84.598,6737.20752,3.840,
5658.72705,83.598,6737.29883,4.840,
5658.81836,83.598,6737.39014,5.840,
5658.91016,84.598,6737.48193,5.840,
5659.00146,84.598,6737.57324,4.840,
5659.09326,84.598,6737.66504,5.840,
5659.18457,83.598,6737.75635,4.840,
5659.27588,84.598,6737.84814,4.840,
5659.36768,84.598,6737.93945,4.840,
5659.45898,84.598,6738.03125,3.840,
5659.55078,84.598,6738.12256,3.840,
5659.64209,83.598,6738.21387,3.840,
5659.73389,83.598,6738.30566,3.840,
5659.82520,83.598,6738.39697,2.840,
5659.91699,84.598,6738.48877,2.840,
5660.00830,83.598,6738.58008,2.840,
5660.09961,83.598,6738.67188,2.840,
5660.19141,83.598,6738.76318,1.840,
5660.28271,83.598,6738.85449,1.840,
5660.37451,83.598,6738.94629,1.840,
5660.46582,83.598,6739.03760,0.840,
5660.55762,84.598,6739.12939,0.840,
5660.64893,83.598,6739.22070,1.840,
5660.74023,83.598,6739.31250,0.840,
5660.83203,83.598,6739.40381,0.840,
5660.92334,83.598,6739.49512,1.840,
5661.01514,83.598,6739.58691,0.840,
5661.10645,83.598,6739.67822,0.840,
5661.19824,83.598,6739.77002,1.840,
5661.28955,83.598,6739.86133,0.840,
5661.38086,83.598,6739.95313,1.840,
5661.47266,83.598,6740.04443,0.840,
5661.56396,83.598,6740.13574,0.840,
5661.65576,82.598,6740.22754,0.840,
5661.74707,82.598,6740.31885,0.840,
5661.83887,83.598,6740.41064,1.840,
5661.93018,82.598,6740.50195,0.840,
5662.02197,83.598,6740.59375,0.840,
5662.11328,83.598,6740.68506,0.840,
5662.20459,82.598,6740.77686,-0.160,
5662.29639,82.598,6740.86816,0.840,
5662.38770,83.598,6740.95947,0.840,
5662.47949,82.598,6741.05127,0.840,
5662.57080,82.598,6741.14258,0.840,
5662.66260,82.598,6741.23438,0.840,
5662.75391,82.598,6741.32568,0.840,
5662.84521,82.598,6741.41748,0.840,
5662.93701,82.598,6741.50879,0.840,
5663.02832,82.598,6741.60010,0.840,
5663.12012,82.598,6741.69189,0.840,
5663.21143,82.598,6741.78320,0.840,
5663.30322,82.598,6741.87500,0.840,
5663.39453,81.598,6741.96631,0.840,
5663.48584,82.598,6742.05811,0.840,
5663.57764,82.598,6742.14941,0.840,
5663.66895,82.598,6742.24072,0.840,
5663.76074,81.598,6742.33252,0.840,
5663.85205,82.598,6742.42383,-0.160,
5663.94385,82.598,6742.51563,0.840,
5664.03516,82.598,6742.60693,0.840,
5664.12695,82.598,6742.69873,0.840,
5664.21826,82.598,6742.79004,0.840,
5664.30957,82.598,6742.88184,1.840,
5664.40137,81.598,6742.97314,0.840,
5664.49268,81.598,6743.06445,0.840,
5664.58447,81.598,6743.15625,0.840,
5664.67578,81.598,6743.24756,0.840,
5664.76758,81.598,6743.33936,0.840,
5664.85889,82.598,6743.43066,0.840,
5664.95020,82.598,6743.52246,0.840,
5665.04199,81.598,6743.61377,-0.160,
5665.13330,82.598,6743.70508,0.840,
5665.22510,81.598,6743.79688,0.840,
5665.31641,81.598,6743.88818,0.840,
5665.40820,81.598,6743.97998,-0.160,
5665.49951,81.598,6744.07129,0.840,
5665.59082,81.598,6744.16309,0.840,
5665.68262,80.598,6744.25439,0.840,
5665.77393,80.598,6744.34570,0.840,
5665.86572,79.598,6744.43750,0.840,
5665.95703,80.598,6744.52881,0.840,
5666.04883,79.598,6744.62061,0.840,
5666.14014,80.598,6744.71191,0.840,
5666.23193,80.598,6744.80371,0.840,
5666.32324,81.598,6744.89502,0.840,
5666.41455,81.598,6744.98682,-0.160,
5666.50635,80.598,6745.07813,0.840,
5666.59766,80.598,6745.16943,0.840,
5666.68945,80.598,6745.26123,0.840,
5666.78076,80.598,6745.35254,0.840,
5666.87256,81.598,6745.44434,0.840,
5666.96387,80.598,6745.53564,0.840,
5667.05518,80.598,6745.62744,1.840,
5667.14697,80.598,6745.71875,0.840,
5667.23828,81.598,6745.81006,0.840,
5667.33008,80.598,6745.90186,0.840,
5667.42139,80.598,6745.99316,1.840,
5667.51318,80.598,6746.08496,0.840,
5667.60449,80.598,6746.17627,0.840,
5667.69580,80.598,6746.26807,0.840,
5667.78760,80.598,6746.35938,-0.160,
5667.87891,80.598,6746.45068,-0.160,
5667.97070,80.598,6746.54248,0.840,
5668.06201,80.598,6746.63379,0.840,
5668.15381,80.598,6746.72559,-0.160,
5668.24512,80.598,6746.81689,-0.160,
5668.33643,80.598,6746.90869,-0.160,
5668.42822,80.598,6747.00000,-0.160,
5668.51953,80.598,6747.09180,0.840,
5668.61133,79.598,6747.18311,-0.160,
5668.70264,79.598,6747.27441,0.840,
5668.79443,80.598,6747.36621,-0.160,
5668.88574,79.598,6747.45752,0.840,
5668.97754,79.598,6747.54932,0.840,
5669.06885,79.598,6747.64063,0.840,
5669.16016,79.598,6747.73242,0.840,
5669.25195,79.598,6747.82373,0.840,
5669.34326,80.598,6747.91504,0.840,
5669.43506,79.598,6748.00684,0.840,
5669.52637,79.598,6748.09814,0.840,
5669.61816,79.598,6748.18994,0.840,
5669.70947,79.598,6748.28125,0.840,
5669.80078,79.598,6748.37305,0.840,
5669.89258,79.598,6748.46436,-0.160,
5669.98389,79.598,6748.55566,0.840,
5670.07568,79.598,6748.64746,0.840,
5670.16699,79.598,6748.73877,0.840,
5670.25879,79.598,6748.83057,0.840,
5670.35010,79.598,6748.92188,0.840,
5670.44141,79.598,6749.01367,0.840,
5670.53320,79.598,6749.10498,-0.160,
5670.62451,79.598,6749.19678,0.840,
5670.71631,78.598,6749.28809,0.840,
5670.80762,79.598,6749.37939,0.840,
5670.89941,79.598,6749.47119,-0.160,
5670.99072,79.598,6749.56250,0.840,
5671.08252,79.598,6749.65430,0.840,
5671.17383,79.598,6749.74561,-0.160,
5671.26514,78.598,6749.83740,0.840,
5671.35693,78.598,6749.92871,0.840,
5671.44824,78.598,6750.02002,0.840,
5671.54004,79.598,6750.11182,-0.160,
5671.63135,78.598,6750.20313,0.840,
5671.72314,78.598,6750.29492,0.840,
5671.81445,78.598,6750.38623,0.840,
5671.90576,78.598,6750.47803,0.840,
5671.99756,78.598,6750.56934,0.840,
5672.08887,78.598,6750.66064,0.840,
5672.18066,78.598,6750.75244,0.840,
5672.27197,79.598,6750.84375,0.840,
5672.36377,78.598,6750.93555,-0.160,
5672.45508,78.598,6751.02686,0.840,
5672.54639,78.598,6751.11865,0.840,
5672.63818,77.598,6751.20996,0.840,
5672.72949,77.598,6751.30176,0.840,
5672.82129,77.598,6751.39307,0.840,
5672.91260,77.598,6751.48438,0.840,
5673.00439,77.598,6751.57617,0.840,
5673.09570,78.598,6751.66748,0.840,
5673.18750,77.598,6751.75928,0.840,
5673.27881,77.598,6751.85059,0.840,
5673.37012,77.598,6751.94238,0.840,
5673.46191,77.598,6752.03369,0.840,
5673.55322,77.598,6752.12500,0.840,
5673.64502,77.598,6752.21680,0.840,
5673.73633,78.598,6752.30811,-0.160,
5673.82813,77.598,6752.39990,0.840,
5673.91943,77.598,6752.49121,-0.160,
5674.01074,78.598,6752.58301,-0.160,
5674.10254,77.598,6752.67432,-0.160,
5674.19385,77.598,6752.76563,-0.160,
5674.28564,77.598,6752.85742,-1.160,
5674.37695,77.598,6752.94873,-0.160,
5674.46875,77.598,6753.04053,-0.160,
5674.56006,77.598,6753.13184,-0.160,
5674.65137,76.598,6753.22363,-0.160,
5674.74316,77.598,6753.31494,-0.160,
5674.83447,76.598,6753.40625,-0.160,
5674.92627,76.598,6753.49805,0.840,
5675.01758,76.598,6753.58936,-0.160,
5675.10938,76.598,6753.68115,0.840,
5675.20068,77.598,6753.77246,0.840,
5675.29248,76.598,6753.86426,-0.160,
5675.38379,77.598,6753.95557,0.840,
5675.47510,76.598,6754.04736,0.840,
5675.56689,76.598,6754.13867,-0.160,
5675.65820,77.598,6754.22998,0.840,
5675.75000,76.598,6754.32178,0.840,
5675.84131,76.598,6754.41309,0.840,
5675.93311,77.598,6754.50488,0.840,
5676.02441,75.598,6754.59619,0.840,
5676.11572,76.598,6754.68799,0.840,
5676.20752,77.598,6754.77930,0.840,
5676.29883,76.598,6754.87061,0.840,
5676.39063,76.598,6754.96240,1.840,
5676.48193,76.598,6755.05371,0.840,
5676.57373,76.598,6755.14551,2.840,
5676.66504,77.598,6755.23682,1.840,
5676.75635,76.598,6755.32861,2.840,
5676.84814,76.598,6755.41992,2.840,
5676.93945,76.598,6755.51123,1.840,
5677.03125,76.598,6755.60303,2.840,
5677.12256,77.598,6755.69434,2.840,
5677.21436,76.598,6755.78613,2.840,
5677.30566,76.598,6755.87744,2.840,
5677.39746,76.598,6755.96924,1.840,
5677.48877,75.598,6756.06055,1.840,
5677.58008,75.598,6756.15234,1.840,
5677.67188,76.598,6756.24365,0.840,
5677.76318,76.598,6756.33496,0.840,
5677.85498,75.598,6756.42676,0.840,
5677.94629,75.598,6756.51807,0.840,
5678.03809,76.598,6756.60986,0.840,
5678.12939,76.598,6756.70117,0.840,
5678.22070,75.598,6756.79297,0.840,
5678.31250,76.598,6756.88428,-0.160,
5678.40381,75.598,6756.97559,0.840,
5678.49561,75.598,6757.06738,0.840,
5678.58691,76.598,6757.15869,0.840,
5678.67871,75.598,6757.25049,-0.160,
5678.77002,75.598,6757.34180,0.840,
5678.86133,75.598,6757.43359,0.840,
5678.95313,75.598,6757.52490,0.840,
5679.04443,75.598,6757.61621,0.840,
5679.13623,75.598,6757.70801,-0.160,
5679.22754,75.598,6757.79932,0.840,
5679.31934,75.598,6757.89111,-0.160,
5679.41064,75.598,6757.98242,0.840,
5679.50244,75.598,6758.07422,-0.160,
5679.59375,75.598,6758.16553,0.840,
5679.68506,74.598,6758.25732,0.840,
5679.77686,75.598,6758.34863,-0.160,
5679.86816,75.598,6758.43994,-0.160,
5679.95996,75.598,6758.53174,-0.160,
5680.05127,75.598,6758.62305,-0.160,
5680.14307,75.598,6758.71484,0.840,
5680.23438,75.598,6758.80615,0.840,
5680.32568,75.598,6758.89795,-0.160,
5680.41748,75.598,6758.98926,-0.160,
5680.50879,74.598,6759.08057,-0.160,
5680.60059,74.598,6759.17236,0.840,
5680.69189,75.598,6759.26367,-0.160,
5680.78369,74.598,6759.35547,-0.160,
5680.87500,74.598,6759.44678,0.840,
5680.96631,74.598,6759.53857,-0.160,
5681.05811,75.598,6759.62988,0.840,
5681.14941,74.598,6759.72119,-0.160,
5681.24121,74.598,6759.81299,0.840,
5681.33252,74.598,6759.90430,-0.160,
5681.42432,74.598,6759.99609,-0.160,
5681.51563,74.598,6760.08740,-0.160,
5681.60693,74.598,6760.17920,-0.160,
5681.69873,74.598,6760.27051,0.840,
5681.79004,74.598,6760.36230,-0.160,
5681.88184,74.598,6760.45361,-0.160,
5681.97314,74.598,6760.54492,-0.160,
5682.06494,74.598,6760.63672,-0.160,
5682.15625,74.598,6760.72803,0.840,
5682.24805,74.598,6760.81982,-0.160,
5682.33936,74.598,6760.91113,-0.160,
5682.43066,74.598,6761.00293,-0.160,
5682.52246,75.598,6761.09424,-0.160,
5682.61377,75.598,6761.18555,-0.160,
5682.70557,74.598,6761.27734,-0.160,
5682.79688,74.598,6761.36865,-0.160,
5682.88867,74.598,6761.46045,-0.160,
5682.97998,74.598,6761.55176,-0.160,
5683.07129,74.598,6761.64355,-0.160,
5683.16309,74.598,6761.73486,-0.160,
5683.25439,74.598,6761.82617,-0.160,
5683.34619,73.598,6761.91797,0.840,
5683.43750,73.598,6762.00928,-0.160,
5683.52930,73.598,6762.10107,-0.160,
5683.62061,73.598,6762.19238,-0.160,
5683.71191,73.598,6762.28418,0.840,
5683.80371,73.598,6762.37549,-0.160,
5683.89502,73.598,6762.46729,-0.160,
5683.98682,73.598,6762.55859,-0.160,
5684.07813,73.598,6762.64990,-0.160,
5684.16992,72.598,6762.74170,-0.160,
5684.26123,73.598,6762.83301,-0.160,
5684.35303,73.598,6762.92480,-0.160,
5684.44434,73.598,6763.01611,-0.160,
5684.53564,73.598,6763.10791,0.840,
5684.62744,73.598,6763.19922,0.840,
5684.71875,73.598,6763.29053,-0.160,
5684.81055,73.598,6763.38232,-0.160,
5684.90186,73.598,6763.47363,0.840,
5684.99365,73.598,6763.56543,-0.160,
5685.08496,73.598,6763.65674,-0.160,
5685.17627,73.598,6763.74854,-0.160,
5685.26807,73.598,6763.83984,-0.160,
5685.35938,73.598,6763.93115,-0.160,
5685.45117,73.598,6764.02295,-0.160,
5685.54248,72.598,6764.11426,-0.160,
5685.63428,72.598,6764.20605,0.840,
5685.72559,72.598,6764.29736,-0.160,
5685.81689,72.598,6764.38916,-0.160,
5685.90869,72.598,6764.48047,-0.160,
5686.00000,72.598,6764.57227,-0.160,
5686.09180,72.598,6764.66357,0.840,
5686.18311,72.598,6764.75488,-0.160,
5686.27490,72.598,6764.84668,-0.160,
5686.36621,71.598,6764.93799,-0.160,
5686.45801,71.598,6765.02979,-0.160,
5686.54932,72.598,6765.12109,0.840,
5686.64063,72.598,6765.21289,-0.160,
5686.73242,71.598,6765.30420,0.840,
5686.82373,72.598,6765.39551,-0.160,
5686.91553,72.598,6765.48730,-0.160,
5687.00684,72.598,6765.57861,-0.160,
5687.09863,72.598,6765.67041,-0.160,
5687.18994,71.598,6765.76172,-0.160,
5687.28125,71.598,6765.85352,-0.160,
5687.37305,71.598,6765.94482,0.840,
5687.46436,72.598,6766.03613,-0.160,
5687.55615,71.598,6766.12793,0.840,
5687.64746,71.598,6766.21924,0.840,
5687.73926,71.598,6766.31104,-0.160,
5687.83057,71.598,6766.40234,0.840,
5687.92188,71.598,6766.49414,0.840,
5688.01367,70.598,6766.58545,0.840,
5688.10498,71.598,6766.67676,-0.160,
5688.19678,71.598,6766.76855,0.840,
5688.28809,71.598,6766.85986,-0.160,
5688.37988,72.598,6766.95166,-0.160,
5688.47119,71.598,6767.04297,0.840,
5688.56299,71.598,6767.13477,0.840,
5688.65430,71.598,6767.22607,-0.160,
5688.74561,71.598,6767.31787,-0.160,
5688.83740,71.598,6767.40918,0.840,
5688.92871,71.598,6767.50049,0.840,
5689.02051,71.598,6767.59229,-0.160,
5689.11182,71.598,6767.68359,0.840,
5689.20361,71.598,6767.77539,0.840,
5689.29492,71.598,6767.86670,0.840,
5689.38623,71.598,6767.95850,-0.160,
5689.47803,70.598,6768.04980,-0.160,
5689.56934,70.598,6768.14111,-0.160,
5689.66113,71.598,6768.23291,-0.160,
5689.75244,71.598,6768.32422,0.840,
5689.84424,71.598,6768.41602,-0.160,
5689.93555,71.598,6768.50732,-0.160,
5690.02686,71.598,6768.59912,-0.160,
5690.11865,71.598,6768.69043,-0.160,
5690.20996,71.598,6768.78174,-0.160,
5690.30176,71.598,6768.87354,-0.160,
5690.39307,71.598,6768.96484,-0.160,
5690.48486,71.598,6769.05664,0.840,
5690.57617,71.598,6769.14795,-0.160,
5690.66797,69.598,6769.23975,0.840,
5690.75928,70.598,6769.33105,-0.160,
5690.85059,70.598,6769.42285,-0.160,
5690.94238,70.598,6769.51416,0.840,
5691.03369,70.598,6769.60547,0.840,
5691.12549,70.598,6769.69727,0.840,
5691.21680,70.598,6769.78857,-0.160,
5691.30859,71.598,6769.88037,-0.160,
5691.39990,71.598,6769.97168,-0.160,
5691.49121,70.598,6770.06348,-0.160,
5691.58301,70.598,6770.15479,-0.160,
5691.67432,70.598,6770.24609,-0.160,
5691.76611,71.598,6770.33789,-0.160,
5691.85742,70.598,6770.42920,-0.160,
5691.94922,70.598,6770.52100,-1.160,
5692.04053,70.598,6770.61230,-2.160,
5692.13184,69.598,6770.70410,-2.160,
5692.22363,69.598,6770.79541,-1.160,
5692.31494,69.598,6770.88672,-1.160,
5692.40674,69.598,6770.97852,-2.160,
5692.49805,69.598,6771.06982,-1.160,
5692.58984,69.598,6771.16162,-1.160,
5692.68115,70.598,6771.25293,-1.160,
5692.77246,70.598,6771.34473,-1.160,
5692.86426,69.598,6771.43604,-1.160,
5692.95557,69.598,6771.52783,-1.160,
5693.04736,69.598,6771.61914,-0.160,
5693.13867,69.598,6771.71045,-0.160,
5693.23047,69.598,6771.80225,-0.160,
5693.32178,69.598,6771.89355,-0.160,
5693.41357,69.598,6771.98535,0.840,
5693.50488,69.598,6772.07666,-0.160,
5693.59619,69.598,6772.16846,-0.160,
5693.68799,69.598,6772.25977,-0.160,
5693.77930,69.598,6772.35107,0.840,
5693.87109,69.598,6772.44287,-0.160,
5693.96240,69.598,6772.53418,1.840,
5694.05420,69.598,6772.62598,1.840,
5694.14551,68.598,6772.71729,1.840,
5694.23682,69.598,6772.80908,2.840,
5694.32861,69.598,6772.90039,2.840,
5694.41992,69.598,6772.99170,2.840,
5694.51172,69.598,6773.08350,3.840,
5694.60303,69.598,6773.17480,4.840,
5694.69482,69.598,6773.26660,4.840,
5694.78613,69.598,6773.35791,3.840,
5694.87744,69.598,6773.44971,4.840,
5694.96924,69.598,6773.54102,4.840,
5695.06055,69.598,6773.63281,3.840,
5695.15234,69.598,6773.72412,3.840,
5695.24365,69.598,6773.81543,3.840,
5695.33545,68.598,6773.90723,2.840,
5695.42676,68.598,6773.99854,3.840,
5695.51855,68.598,6774.09033,3.840,
5695.60986,68.598,6774.18164,2.840,
5695.70117,69.598,6774.27344,1.840,
5695.79297,68.598,6774.36475,1.840,
5695.88428,68.598,6774.45605,1.840,
5695.97607,68.598,6774.54785,1.840,
5696.06738,68.598,6774.63916,0.840,
5696.15918,68.598,6774.73096,0.840,
5696.25049,68.598,6774.82227,0.840,
5696.34180,68.598,6774.91406,0.840,
5696.43359,68.598,6775.00537,0.840,
5696.52490,68.598,6775.09668,0.840,
5696.61670,68.598,6775.18848,0.840,
5696.70801,67.598,6775.27979,-0.160,
5696.79980,67.598,6775.37158,-0.160,
5696.89111,67.598,6775.46289,-0.160,
5696.98242,68.598,6775.55469,-0.160,
5697.07422,67.598,6775.64600,0.840,
5697.16553,68.598,6775.73779,0.840,
5697.25732,68.598,6775.82910,-0.160,
5697.34863,68.598,6775.92041,-0.160,
5697.44043,68.598,6776.01221,-0.160,
5697.53174,67.598,6776.10352,-0.160,
5697.62354,68.598,6776.19531,0.840,
5697.71484,67.598,6776.28662,0.840,
5697.80615,67.598,6776.37842,1.840,
5697.89795,68.598,6776.46973,0.840,
5697.98926,67.598,6776.56104,0.840,
5698.08105,67.598,6776.65283,0.840,
5698.17236,67.598,6776.74414,0.840,
5698.26416,67.598,6776.83594,0.840,
5698.35547,67.598,6776.92725,0.840,
5698.44678,67.598,6777.01904,1.840,
5698.53857,67.598,6777.11035,0.840,
5698.62988,67.598,6777.20166,1.840,
5698.72168,67.598,6777.29346,0.840,
5698.81299,67.598,6777.38477,0.840,
5698.90479,68.598,6777.47656,0.840,
5698.99609,67.598,6777.56787,0.840,
5699.08740,67.598,6777.65967,0.840,
5699.17920,67.598,6777.75098,0.840,
5699.27051,67.598,6777.84229,1.840,
5699.36230,67.598,6777.93408,0.840,
5699.45361,67.598,6778.02539,0.840,
5699.54541,67.598,6778.11719,0.840,
5699.63672,66.598,6778.20850,0.840,
5699.72852,67.598,6778.30029,0.840,
5699.81982,67.598,6778.39160,0.840,
5699.91113,67.598,6778.48340,0.840,
5700.00293,66.598,6778.57471,0.840,
5700.09424,67.598,6778.66602,0.840,
5700.18604,66.598,6778.75781,0.840,
5700.27734,66.598,6778.84912,0.840,
5700.36914,66.598,6778.94092,0.840,
5700.46045,66.598,6779.03223,0.840,
5700.55176,67.598,6779.12402,0.840,
5700.64355,66.598,6779.21533,0.840,
5700.73486,66.598,6779.30664,1.840,
5700.82666,66.598,6779.39844,1.840,
5700.91797,66.598,6779.48975,0.840,
5701.00977,66.598,6779.58154,0.840,
5701.10107,66.598,6779.67285,0.840,
5701.19238,66.598,6779.76465,0.840,
5701.28418,66.598,6779.85596,0.840,
5701.37549,66.598,6779.94727,1.840,
5701.46729,65.598,6780.03906,0.840,
5701.55859,66.598,6780.13037,0.840,
5701.65039,65.598,6780.22217,0.840,
5701.74170,66.598,6780.31348,0.840,
5701.83350,66.598,6780.40527,0.840,
5701.92480,66.598,6780.49658,0.840,
5702.01611,66.598,6780.58838,0.840,
5702.10791,66.598,6780.67969,0.840,
5702.19922,66.598,6780.77100,0.840,
5702.29102,66.598,6780.86279,0.840,
5702.38232,65.598,6780.95410,0.840,
5702.47412,65.598,6781.04590,0.840,
5702.56543,65.598,6781.13721,0.840,
5702.65674,65.598,6781.22900,0.840,
5702.74854,65.598,6781.32031,0.840,
5702.83984,65.598,6781.41162,0.840,
5702.93164,65.598,6781.50342,0.840,
5703.02295,65.598,6781.59473,0.840,
5703.11475,65.598,6781.68652,0.840,
5703.20605,65.598,6781.77783,-0.160,
5703.29736,66.598,6781.86963,0.840,
5703.38916,65.598,6781.96094,-0.160,
5703.48047,65.598,6782.05225,0.840,
5703.57227,65.598,6782.14404,0.840,
5703.66357,65.598,6782.23535,1.840,
5703.75537,66.598,6782.32715,0.840,
5703.84668,65.598,6782.41846,0.840,
5703.93848,65.598,6782.51025,0.840,
5704.02979,65.598,6782.60156,0.840,
5704.12109,64.598,6782.69336,0.840,
5704.21289,64.598,6782.78467,1.840,
5704.30420,65.598,6782.87598,0.840,
5704.39600,64.598,6782.96777,0.840,
5704.48730,65.598,6783.05908,0.840,
5704.57910,64.598,6783.15088,0.840,
5704.67041,65.598,6783.24219,0.840,
5704.76172,65.598,6783.33398,0.840,
5704.85352,64.598,6783.42529,1.840,
5704.94482,65.598,6783.51660,-0.160,
5705.03662,64.598,6783.60840,0.840,
5705.12793,64.598,6783.69971,1.840,
5705.21973,65.598,6783.79150,0.840,
5705.31104,64.598,6783.88281,0.840,
5705.40234,64.598,6783.97461,0.840,
5705.49414,64.598,6784.06592,0.840,
5705.58545,64.598,6784.15723,0.840,
5705.67725,64.598,6784.24902,0.840,
5705.76855,64.598,6784.34033,0.840,
5705.86035,65.598,6784.43213,0.840,
5705.95166,65.598,6784.52344,0.840,
5706.04297,64.598,6784.61523,0.840,
5706.13477,64.598,6784.70654,0.840,
5706.22607,64.598,6784.79834,0.840,
5706.31787,64.598,6784.88965,0.840,
5706.40918,64.598,6784.98096,0.840,
5706.50098,64.598,6785.07275,0.840,
5706.59229,64.598,6785.16406,0.840,
5706.68408,64.598,6785.25586,0.840,
5706.77539,64.598,6785.34717,0.840,
5706.86670,63.598,6785.43896,0.840,
5706.95850,64.598,6785.53027,0.840,
5707.04980,64.598,6785.62158,0.840,
5707.14160,64.598,6785.71338,0.840,
5707.23291,64.598,6785.80469,0.840,
5707.32471,64.598,6785.89648,0.840,
5707.41602,65.598,6785.98779,0.840,
5707.50732,64.598,6786.07959,0.840,
5707.59912,64.598,6786.17090,0.840,
5707.69043,64.598,6786.26221,0.840,
5707.78223,64.598,6786.35400,0.840,
5707.87354,64.598,6786.44531,0.840,
5707.96533,64.598,6786.53711,0.840,
5708.05664,64.598,6786.62842,0.840,
5708.14795,63.598,6786.72021,1.840,
5708.23975,63.598,6786.81152,1.840,
5708.33105,63.598,6786.90332,0.840,
5708.42285,64.598,6786.99463,0.840,
5708.51416,63.598,6787.08594,1.840,
5708.60596,63.598,6787.17773,0.840,
5708.69727,63.598,6787.26904,0.840,
5708.78906,63.598,6787.36084,1.840,
5708.88037,64.598,6787.45215,0.840,
5708.97168,63.598,6787.54395,0.840,
5709.06348,64.598,6787.63525,0.840,
5709.15479,64.598,6787.72656,0.840,
5709.24658,63.598,6787.81836,0.840,
5709.33789,63.598,6787.90967,0.840,
5709.42969,63.598,6788.00146,0.840,
5709.52100,63.598,6788.09277,1.840,
5709.61230,63.598,6788.18457,1.840,
5709.70410,63.598,6788.27588,1.840,
5709.79541,63.598,6788.36719,1.840,
5709.88721,63.598,6788.45898,2.840,
5709.97852,63.598,6788.55029,2.840,
5710.07031,62.598,6788.64209,2.840,
5710.16162,63.598,6788.73340,2.840,
5710.25293,63.598,6788.82520,2.840,
5710.34473,62.598,6788.91650,2.840,
5710.43604,62.598,6789.00830,2.840,
5710.52783,63.598,6789.09961,2.840,
5710.61914,63.598,6789.19092,2.840,
5710.71094,63.598,6789.28271,2.840,
5710.80225,63.598,6789.37402,2.840,
5710.89404,62.598,6789.46582,2.840,
5710.98535,62.598,6789.55713,2.840,
5711.07666,63.598,6789.64893,1.840,
5711.16846,62.598,6789.74023,1.840,
5711.25977,62.598,6789.83154,1.840,
5711.35156,62.598,6789.92334,1.840,
5711.44287,62.598,6790.01465,1.840,
5711.53467,62.598,6790.10645,1.840,
5711.62598,62.598,6790.19775,1.840,
5711.71729,62.598,6790.28955,0.840,
5711.80908,63.598,6790.38086,0.840,
5711.90039,62.598,6790.47217,0.840,
5711.99219,62.598,6790.56396,-0.160,
5712.08350,62.598,6790.65527,-0.160,
5712.17529,62.598,6790.74707,-0.160,
5712.26660,62.598,6790.83838,-1.160,
5712.35791,62.598,6790.93018,-1.160,
5712.44971,62.598,6791.02148,-0.160,
5712.54102,61.598,6791.11279,-1.160,
5712.63281,61.598,6791.20459,-1.160,
5712.72412,61.598,6791.29590,-1.160,
5712.81592,61.598,6791.38770,-1.160,
5712.90723,62.598,6791.47900,-1.160,
5712.99902,62.598,6791.57080,-1.160,
5713.09033,61.598,6791.66211,-2.160,
5713.18164,61.598,6791.75391,-1.160,
5713.27344,62.598,6791.84521,-2.160,
5713.36475,61.598,6791.93652,-1.160,
5713.45654,62.598,6792.02832,-1.160,
5713.54785,61.598,6792.11963,-1.160,
5713.63965,62.598,6792.21143,-1.160,
5713.73096,61.598,6792.30273,-1.160,
5713.82227,61.598,6792.39453,-1.160,
5713.91406,62.598,6792.48584,-0.160,
5714.00537,61.598,6792.57715,-0.160,
5714.09717,61.598,6792.66895,-0.160,
5714.18848,61.598,6792.76025,0.840,
5714.28027,61.598,6792.85205,0.840,
5714.37158,61.598,6792.94336,0.840,
5714.46289,61.598,6793.03516,0.840,
5714.55469,61.598,6793.12646,0.840,
5714.64600,61.598,6793.21777,0.840,
5714.73779,62.598,6793.30957,-0.160,
5714.82910,61.598,6793.40088,0.840,
5714.92090,61.598,6793.49268,0.840,
5715.01221,61.598,6793.58398,-0.160,
5715.10400,61.598,6793.67578,0.840,
5715.19531,61.598,6793.76709,0.840,
5715.28662,61.598,6793.85889,0.840,
5715.37842,61.598,6793.95020,0.840,
5715.46973,61.598,6794.04150,0.840,
5715.56152,60.598,6794.13330,0.840,
5715.65283,60.598,6794.22461,0.840,
5715.74463,61.598,6794.31641,0.840,
5715.83594,61.598,6794.40771,0.840,
5715.92725,61.598,6794.49951,0.840,
5716.01904,61.598,6794.59082,0.840,
5716.11035,61.598,6794.68213,-0.160,
5716.20215,61.598,6794.77393,0.840,
5716.29346,61.598,6794.86523,0.840,
5716.38525,61.598,6794.95703,0.840,
5716.47656,60.598,6795.04834,0.840,
5716.56787,61.598,6795.14014,0.840,
5716.65967,61.598,6795.23145,-0.160,
5716.75098,60.598,6795.32275,0.840,
5716.84277,60.598,6795.41455,0.840,
5716.93408,61.598,6795.50586,-0.160,
5717.02588,61.598,6795.59766,-0.160,
5717.11719,60.598,6795.68896,-0.160,
5717.20898,61.598,6795.78076,-0.160,
5717.30029,60.598,6795.87207,0.840,
5717.39160,60.598,6795.96387,0.840,
5717.48340,60.598,6796.05518,-0.160,
5717.57471,60.598,6796.14648,0.840,
5717.66650,61.598,6796.23828,0.840,
5717.75781,60.598,6796.32959,0.840,
5717.84961,60.598,6796.42139,0.840,
5717.94092,60.598,6796.51270,0.840,
5718.03223,60.598,6796.60449,0.840,
5718.12402,60.598,6796.69580,-0.160,
5718.21533,60.598,6796.78711,0.840,
5718.30713,60.598,6796.87891,1.840,
5718.39844,60.598,6796.97021,0.840,
5718.49023,60.598,6797.06201,0.840,
5718.58154,59.598,6797.15332,0.840,
5718.67285,60.598,6797.24512,0.840,
5718.76465,60.598,6797.33643,0.840,
5718.85596,59.598,6797.42773,0.840,
5718.94775,59.598,6797.51953,0.840,
5719.03906,60.598,6797.61084,0.840,
5719.13086,60.598,6797.70264,0.840,
5719.22217,59.598,6797.79395,-0.160,
5719.31348,59.598,6797.88574,0.840,
5719.40527,60.598,6797.97705,0.840,
5719.49658,59.598,6798.06885,0.840,
5719.58838,59.598,6798.16016,0.840,
5719.67969,59.598,6798.25146,-0.160,
5719.77148,59.598,6798.34326,0.840,
5719.86279,59.598,6798.43457,0.840,
5719.95459,59.598,6798.52637,0.840,
5720.04590,58.598,6798.61768,0.840,
5720.13721,58.598,6798.70947,0.840,
5720.22900,58.598,6798.80078,0.840,
5720.32031,58.598,6798.89209,0.840,
5720.41211,58.598,6798.98389,0.840,
5720.50342,58.598,6799.07520,0.840,
5720.59521,59.598,6799.16699,0.840,
5720.68652,59.598,6799.25830,0.840,
5720.77783,59.598,6799.35010,0.840,
5720.86963,59.598,6799.44141,-0.160,
5720.96094,59.598,6799.53271,0.840,
5721.05273,59.598,6799.62451,0.840,
5721.14404,59.598,6799.71582,0.840,
5721.23584,59.598,6799.80762,1.840,
5721.32715,59.598,6799.89893,0.840,
5721.41846,58.598,6799.99072,0.840,
5721.51025,59.598,6800.08203,-0.160,
5721.60156,59.598,6800.17383,0.840,
5721.69336,59.598,6800.26514,0.840,
5721.78467,59.598,6800.35645,0.840,
5721.87646,59.598,6800.44824,-0.160,
5721.96777,58.598,6800.53955,0.840,
5722.05957,59.598,6800.63135,0.840,
5722.15088,58.598,6800.72266,-0.160,
5722.24219,58.598,6800.81445,0.840,
5722.33398,58.598,6800.90576,0.840,
5722.42529,58.598,6800.99707,-0.160,
5722.51709,57.598,6801.08887,0.840,
5722.60840,57.598,6801.18018,0.840,
5722.70020,57.598,6801.27197,0.840,
5722.79150,57.598,6801.36328,0.840,
5722.88281,57.598,6801.45508,0.840,
5722.97461,57.598,6801.54639,0.840,
5723.06592,57.598,6801.63770,0.840,
5723.15771,57.598,6801.72949,0.840,
5723.24902,58.598,6801.82080,0.840,
5723.34082,58.598,6801.91260,0.840,
5723.43213,58.598,6802.00391,0.840,
5723.52344,58.598,6802.09570,0.840,
5723.61523,58.598,6802.18701,0.840,
5723.70654,58.598,6802.27832,0.840,
5723.79834,58.598,6802.37012,0.840,
5723.88965,57.598,6802.46143,0.840,
5723.98145,58.598,6802.55322,-0.160,
5724.07275,58.598,6802.64453,0.840,
5724.16455,58.598,6802.73633,0.840,
5724.25586,58.598,6802.82764,-0.160,
5724.34717,57.598,6802.91943,0.840,
5724.43896,57.598,6803.01074,0.840,
5724.53027,58.598,6803.10205,-0.160,
5724.62207,57.598,6803.19385,0.840,
5724.71338,58.598,6803.28516,0.840,
5724.80518,57.598,6803.37695,0.840,
5724.89648,58.598,6803.46826,-0.160,
5724.98779,58.598,6803.56006,-0.160,
5725.07959,58.598,6803.65137,0.840,
5725.17090,57.598,6803.74268,0.840,
5725.26270,58.598,6803.83447,0.840,
5725.35400,57.598,6803.92578,0.840,
5725.44580,57.598,6804.01758,-0.160,
5725.53711,57.598,6804.10889,0.840,
5725.62842,57.598,6804.20068,1.840,
5725.72021,57.598,6804.29199,0.840,
5725.81152,57.598,6804.38330,0.840,
5725.90332,57.598,6804.47510,-0.160,
5725.99463,56.598,6804.56641,0.840,
5726.08643,57.598,6804.65820,-0.160,
5726.17773,57.598,6804.74951,0.840,
5726.26953,56.598,6804.84131,0.840,
5726.36084,57.598,6804.93262,0.840,
5726.45215,57.598,6805.02441,-0.160,
5726.54395,57.598,6805.11572,-0.160,
5726.63525,57.598,6805.20703,0.840,
5726.72705,57.598,6805.29883,-0.160,
5726.81836,57.598,6805.39014,-0.160,
5726.91016,57.598,6805.48193,-0.160,
5727.00146,57.598,6805.57324,-0.160,
5727.09277,57.598,6805.66504,0.840,
5727.18457,57.598,6805.75635,-0.160,
5727.27588,57.598,6805.84766,-0.160,
5727.36768,57.598,6805.93945,-0.160,
5727.45898,57.598,6806.03076,0.840,
5727.55078,56.598,6806.12256,-0.160,
5727.64209,57.598,6806.21387,-0.160,
5727.73340,57.598,6806.30566,-0.160,
5727.82520,57.598,6806.39697,-1.160,
5727.91650,57.598,6806.48828,-1.160,
5728.00830,57.598,6806.58008,-1.160,
5728.09961,56.598,6806.67139,-0.160,
5728.19141,57.598,6806.76318,-1.160,
5728.28271,57.598,6806.85449,-1.160,
5728.37451,56.598,6806.94629,-0.160,
5728.46582,57.598,6807.03760,-0.160,
5728.55713,56.598,6807.12939,-0.160,
5728.64893,56.598,6807.22070,-0.160,
5728.74023,56.598,6807.31201,-0.160,
5728.83203,56.598,6807.40381,-0.160,
5728.92334,56.598,6807.49512,0.840,
5729.01514,56.598,6807.58691,0.840,
5729.10645,56.598,6807.67822,-0.160,
5729.19775,56.598,6807.77002,0.840,
5729.28955,56.598,6807.86133,0.840,
5729.38086,57.598,6807.95264,0.840,
5729.47266,56.598,6808.04443,-0.160,
5729.56396,56.598,6808.13574,-0.160,
5729.65576,56.598,6808.22754,-0.160,
5729.74707,56.598,6808.31885,-0.160,
5729.83838,56.598,6808.41064,-0.160,
5729.93018,56.598,6808.50195,0.840,
5730.02148,56.598,6808.59326,0.840,
5730.11328,56.598,6808.68506,-0.160,
5730.20459,56.598,6808.77637,0.840,
5730.29639,55.598,6808.86816,0.840,
5730.38770,56.598,6808.95947,0.840,
5730.47900,56.598,6809.05127,0.840,
5730.57080,56.598,6809.14258,0.840,
5730.66211,56.598,6809.23438,0.840,
5730.75391,56.598,6809.32568,0.840,
5730.84521,56.598,6809.41699,0.840,
5730.93701,55.598,6809.50879,-0.160,
5731.02832,55.598,6809.60010,-0.160,
5731.12012,56.598,6809.69189,-0.160,
5731.21143,55.598,6809.78320,-0.160,
5731.30273,55.598,6809.87500,-0.160,
5731.39453,55.598,6809.96631,-0.160,
5731.48584,55.598,6810.05762,-0.160,
5731.57764,55.598,6810.14941,-0.160,
5731.66895,55.598,6810.24072,-0.160,
5731.76074,55.598,6810.33252,-0.160,
5731.85205,55.598,6810.42383,-0.160,
5731.94336,55.598,6810.51563,-0.160,
5732.03516,55.598,6810.60693,-0.160,
5732.12646,55.598,6810.69824,-0.160,
5732.21826,55.598,6810.79004,-0.160,
5732.30957,56.598,6810.88135,-0.160,
5732.40137,55.598,6810.97314,-0.160,
5732.49268,55.598,6811.06445,-0.160,
5732.58398,55.598,6811.15625,-0.160,
5732.67578,55.598,6811.24756,-0.160,
5732.76709,55.598,6811.33936,-0.160,
5732.85889,55.598,6811.43066,-0.160,
5732.95020,55.598,6811.52197,0.840,
5733.04199,55.598,6811.61377,-0.160,
5733.13330,55.598,6811.70508,-0.160,
5733.22510,55.598,6811.79688,-0.160,
5733.31641,55.598,6811.88818,-0.160,
5733.40771,55.598,6811.97998,-0.160,
5733.49951,54.598,6812.07129,-0.160,
5733.59082,54.598,6812.16260,0.840,
5733.68262,54.598,6812.25439,-0.160,
5733.77393,55.598,6812.34570,-0.160,
5733.86572,54.598,6812.43750,-0.160,
5733.95703,55.598,6812.52881,0.840,
5734.04834,54.598,6812.62061,-0.160,
5734.14014,55.598,6812.71191,-0.160,
5734.23145,55.598,6812.80322,-0.160,
5734.32324,54.598,6812.89502,-0.160,
5734.41455,55.598,6812.98633,-0.160,
5734.50635,54.598,6813.07813,-0.160,
5734.59766,54.598,6813.16943,-0.160,
5734.68896,54.598,6813.26123,-0.160,
5734.78076,54.598,6813.35254,-0.160,
5734.87207,54.598,6813.44434,-0.160,
5734.96387,54.598,6813.53564,-0.160,
5735.05518,54.598,6813.62695,-0.160,
5735.14697,54.598,6813.71875,-0.160,
5735.23828,55.598,6813.81006,-1.160,
5735.33008,54.598,6813.90186,-0.160,
5735.42139,53.598,6813.99316,-0.160,
5735.51270,54.598,6814.08496,-0.160,
5735.60449,54.598,6814.17627,-0.160,
5735.69580,54.598,6814.26758,-0.160,
5735.78760,53.598,6814.35938,-0.160,
5735.87891,54.598,6814.45068,0.840,
5735.97070,54.598,6814.54248,-0.160,
5736.06201,54.598,6814.63379,-0.160,
5736.15332,53.598,6814.72559,-0.160,
5736.24512,54.598,6814.81689,-0.160,
5736.33643,53.598,6814.90820,-0.160,
5736.42822,53.598,6815.00000,-0.160,
5736.51953,53.598,6815.09131,-0.160,
5736.61133,54.598,6815.18311,-0.160,
5736.70264,54.598,6815.27441,-0.160,
5736.79395,53.598,6815.36621,-0.160,
5736.88574,53.598,6815.45752,-0.160,
5736.97705,54.598,6815.54883,-0.160,
5737.06885,53.598,6815.64063,-0.160,
5737.16016,54.598,6815.73193,-0.160,
5737.25195,53.598,6815.82373,-0.160,
5737.34326,53.598,6815.91504,-0.160,
5737.43506,53.598,6816.00684,-0.160,
5737.52637,53.598,6816.09814,-0.160,
5737.61768,53.598,6816.18994,-0.160,
5737.70947,53.598,6816.28125,-0.160,
5737.80078,53.598,6816.37256,-0.160,
5737.89258,53.598,6816.46436,-0.160,
5737.98389,53.598,6816.55566,-0.160,
5738.07568,53.598,6816.64746,-0.160,
5738.16699,54.598,6816.73877,-0.160,
5738.25830,53.598,6816.83057,-0.160,
5738.35010,53.598,6816.92188,-0.160,
5738.44141,53.598,6817.01318,-0.160,
5738.53320,53.598,6817.10498,-0.160,
5738.62451,54.598,6817.19629,-0.160,
5738.71631,54.598,6817.28809,-0.160,
5738.80762,53.598,6817.37939,-0.160,
5738.89893,53.598,6817.47119,-0.160,
5738.99072,53.598,6817.56250,-1.160,
5739.08203,53.598,6817.65381,-0.160,
5739.17383,53.598,6817.74561,-0.160,
5739.26514,52.598,6817.83691,-1.160,
5739.35693,53.598,6817.92871,-1.160,
5739.44824,52.598,6818.02002,-0.160,
5739.54004,52.598,6818.11182,-0.160,
5739.63135,53.598,6818.20313,-0.160,
5739.72266,52.598,6818.29492,-1.160,
5739.81445,52.598,6818.38623,-1.160,
5739.90576,53.598,6818.47754,-1.160,
5739.99756,52.598,6818.56934,-0.160,
5740.08887,52.598,6818.66064,-0.160,
5740.18066,52.598,6818.75244,-1.160,
5740.27197,52.598,6818.84375,-0.160,
5740.36328,52.598,6818.93555,-0.160,
5740.45508,53.598,6819.02686,-0.160,
5740.54639,53.598,6819.11816,-0.160,
5740.63818,53.598,6819.20996,-0.160,
5740.72949,54.598,6819.30127,-1.160,
5740.82129,54.598,6819.39307,-1.160,
5740.91260,54.598,6819.48438,-0.160,
5741.00391,53.598,6819.57617,-0.160,
5741.09570,54.598,6819.66748,-1.160,
5741.18701,53.598,6819.75879,-1.160,
5741.27881,53.598,6819.85059,-1.160,
5741.37012,52.598,6819.94189,-1.160,
5741.46191,52.598,6820.03369,-1.160,
5741.55322,52.598,6820.12500,-1.160,
5741.64502,52.598,6820.21680,-0.160,
5741.73633,52.598,6820.30811,-0.160,
5741.82764,52.598,6820.39990,-1.160,
5741.91943,51.598,6820.49121,-0.160,
5742.01074,51.598,6820.58252,-0.160,
5742.10254,51.598,6820.67432,-0.160,
5742.19385,51.598,6820.76563,-0.160,
5742.28564,51.598,6820.85742,-0.160,
5742.37695,51.598,6820.94873,-1.160,
5742.46826,51.598,6821.04053,-0.160,
5742.56006,52.598,6821.13184,-0.160,
5742.65137,52.598,6821.22314,-1.160,
5742.74316,51.598,6821.31494,-1.160,
5742.83447,51.598,6821.40625,-1.160,
5742.92627,51.598,6821.49805,-1.160,
5743.01758,51.598,6821.58936,-0.160,
5743.10889,51.598,6821.68115,-1.160,
5743.20068,51.598,6821.77246,-0.160,
5743.29199,51.598,6821.86377,-0.160,
5743.38379,51.598,6821.95557,-1.160,
5743.47510,51.598,6822.04688,-0.160,
5743.56689,51.598,6822.13867,-1.160,
5743.65820,51.598,6822.22998,-0.160,
5743.74951,51.598,6822.32178,-1.160,
5743.84131,51.598,6822.41309,-0.160,
5743.93262,51.598,6822.50488,-0.160,
5744.02441,51.598,6822.59619,-1.160,
5744.11572,51.598,6822.68750,-1.160,
5744.20752,51.598,6822.77930,-1.160,
5744.29883,51.598,6822.87061,-1.160,
5744.39063,51.598,6822.96240,-1.160,
5744.48193,50.598,6823.05371,-1.160,
5744.57324,51.598,6823.14551,-0.160,
5744.66504,51.598,6823.23682,-0.160,
5744.75635,51.598,6823.32813,-1.160,
5744.84814,51.598,6823.41992,-1.160,
5744.93945,50.598,6823.51123,-0.160,
5745.03125,50.598,6823.60303,-0.160,
5745.12256,51.598,6823.69434,-1.160,
5745.21387,51.598,6823.78613,-0.160,
5745.30566,50.598,6823.87744,-0.160,
5745.39697,51.598,6823.96875,-1.160,
5745.48877,51.598,6824.06055,-1.160,
5745.58008,50.598,6824.15186,-1.160,
5745.67188,50.598,6824.24365,-1.160,
5745.76318,51.598,6824.33496,-1.160,
5745.85449,50.598,6824.42676,-1.160,
5745.94629,50.598,6824.51807,-1.160,
5746.03760,51.598,6824.60986,-0.160,
5746.12939,50.598,6824.70117,-0.160,
5746.22070,50.598,6824.79248,-0.160,
5746.31250,50.598,6824.88428,-0.160,
5746.40381,50.598,6824.97559,-1.160,
5746.49561,50.598,6825.06738,-1.160,
5746.58691,50.598,6825.15869,-1.160,
5746.67822,50.598,6825.25049,-1.160,
5746.77002,50.598,6825.34180,-2.160,
5746.86133,50.598,6825.43311,-1.160,
5746.95313,51.598,6825.52490,-2.160,
5747.04443,50.598,6825.61621,-2.160,
5747.13623,50.598,6825.70801,-1.160,
5747.22754,50.598,6825.79932,-2.160,
5747.31885,50.598,6825.89111,-2.160,
5747.41064,50.598,6825.98242,-2.160,
5747.50195,50.598,6826.07373,-1.160,
5747.59375,50.598,6826.16553,-1.160,
5747.68506,50.598,6826.25684,-2.160,
5747.77686,50.598,6826.34863,-2.160,
5747.86816,50.598,6826.43994,-2.160,
5747.95947,50.598,6826.53174,-1.160,
5748.05127,50.598,6826.62305,-1.160,
5748.14258,50.598,6826.71484,-1.160,
5748.23438,50.598,6826.80615,-1.160,
5748.32568,50.598,6826.89746,-1.160,
5748.41748,50.598,6826.98926,-1.160,
5748.50879,50.598,6827.08057,-1.160,
5748.60059,50.598,6827.17236,-1.160,
5748.69189,50.598,6827.26367,-0.160,
5748.78320,50.598,6827.35547,-0.160,
5748.87500,50.598,6827.44678,0.840,
5748.96631,49.598,6827.53809,0.840,
5749.05811,50.598,6827.62988,0.840,
5749.14941,50.598,6827.72119,0.840,
5749.24121,49.598,6827.81299,0.840,
5749.33252,49.598,6827.90430,-0.160,
5749.42383,50.598,6827.99609,-0.160,
5749.51563,49.598,6828.08740,0.840,
5749.60693,49.598,6828.17871,-0.160,
5749.69873,49.598,6828.27051,-0.160,
5749.79004,49.598,6828.36182,-0.160,
5749.88184,50.598,6828.45361,-0.160,
5749.97314,49.598,6828.54492,-0.160,
5750.06445,50.598,6828.63672,-1.160,
5750.15625,49.598,6828.72803,-1.160,
5750.24756,49.598,6828.81934,-1.160,
5750.33936,49.598,6828.91113,-1.160,
5750.43066,49.598,6829.00244,-0.160,
5750.52246,49.598,6829.09424,-0.160,
5750.61377,49.598,6829.18555,-1.160,
5750.70557,48.598,6829.27734,-1.160,
5750.79688,49.598,6829.36865,-1.160,
5750.88818,49.598,6829.46045,-1.160,
5750.97998,49.598,6829.55176,-1.160,
5751.07129,49.598,6829.64307,-1.160,
5751.16309,49.598,6829.73486,-1.160,
5751.25439,49.598,6829.82617,-1.160,
5751.34619,49.598,6829.91797,-1.160,
5751.43750,49.598,6830.00928,-1.160,
5751.52881,49.598,6830.10107,-1.160,
5751.62061,49.598,6830.19238,-1.160,
5751.71191,49.598,6830.28369,-1.160,
5751.80371,49.598,6830.37549,-1.160,
5751.89502,49.598,6830.46680,-1.160,
5751.98682,49.598,6830.55859,-1.160,
5752.07813,49.598,6830.64990,-1.160,
5752.16943,48.598,6830.74170,-1.160,
5752.26123,48.598,6830.83301,-1.160,
5752.35254,48.598,6830.92432,-2.160,
5752.44434,48.598,6831.01611,-1.160,
5752.53564,48.598,6831.10742,-1.160,
5752.62744,47.598,6831.19922,-1.160,
5752.71875,48.598,6831.29053,-1.160,
5752.81055,48.598,6831.38232,-1.160,
5752.90186,49.598,6831.47363,-1.160,
5752.99316,48.598,6831.56543,-1.160,
5753.08496,49.598,6831.65674,-1.160,
5753.17627,48.598,6831.74805,-1.160,
5753.26807,48.598,6831.83984,-1.160,
5753.35938,48.598,6831.93115,-1.160,
5753.45117,48.598,6832.02295,-1.160,
5753.54248,48.598,6832.11426,-1.160,
5753.63379,48.598,6832.20605,-1.160,
5753.72559,48.598,6832.29736,-1.160,
5753.81689,48.598,6832.38867,-1.160,
5753.90869,48.598,6832.48047,-1.160,
5754.00000,48.598,6832.57178,-1.160,
5754.09180,48.598,6832.66357,-1.160,
5754.18311,47.598,6832.75488,-1.160,
5754.27441,48.598,6832.84668,-1.160,
5754.36621,48.598,6832.93799,-2.160,
5754.45752,47.598,6833.02930,-2.160,
5754.54932,48.598,6833.12109,-2.160,
5754.64063,48.598,6833.21240,-2.160,
5754.73242,48.598,6833.30420,-2.160,
5754.82373,47.598,6833.39551,-2.160,
5754.91504,47.598,6833.48730,-1.160,
5755.00684,47.598,6833.57861,-1.160,
5755.09814,48.598,6833.67041,-1.160,
5755.18994,48.598,6833.76172,-2.160,
5755.28125,48.598,6833.85303,-1.160,
5755.37305,47.598,6833.94482,-1.160,
5755.46436,47.598,6834.03613,-1.160,
5755.55615,47.598,6834.12793,-2.160,
5755.64746,48.598,6834.21924,-2.160,
5755.73877,48.598,6834.31104,-1.160,
5755.83057,48.598,6834.40234,-2.160,
5755.92188,47.598,6834.49365,-2.160,
5756.01367,47.598,6834.58545,-2.160,
5756.10498,48.598,6834.67676,-1.160,
5756.19678,48.598,6834.76855,-2.160,
5756.28809,48.598,6834.85986,-1.160,
5756.37939,47.598,6834.95166,-0.160,
5756.47119,47.598,6835.04297,-2.160,
5756.56250,47.598,6835.13428,-1.160,
5756.65430,47.598,6835.22607,-1.160,
5756.74561,47.598,6835.31738,-2.160,
5756.83740,47.598,6835.40918,-2.160,
5756.92871,47.598,6835.50049,-1.160,
5757.02002,47.598,6835.59229,-2.160,
5757.11182,47.598,6835.68359,-1.160,
5757.20313,48.598,6835.77539,-1.160,
5757.29492,47.598,6835.86670,-2.160,
5757.38623,47.598,6835.95801,-1.160,
5757.47803,47.598,6836.04980,-1.160,
5757.56934,47.598,6836.14111,-1.160,
5757.66113,47.598,6836.23291,-2.160,
5757.75244,47.598,6836.32422,-1.160,
5757.84375,46.598,6836.41602,-1.160,
5757.93555,47.598,6836.50732,-2.160,
5758.02686,46.598,6836.59863,-2.160,
5758.11865,47.598,6836.69043,-1.160,
5758.20996,47.598,6836.78174,-1.160,
5758.30176,46.598,6836.87354,-1.160,
5758.39307,46.598,6836.96484,-1.160,
5758.48438,46.598,6837.05664,-1.160,
5758.57617,47.598,6837.14795,-1.160,
5758.66748,47.598,6837.23926,-2.160,
5758.75928,46.598,6837.33105,-1.160,
5758.85059,46.598,6837.42236,-1.160,
5758.94238,46.598,6837.51416,-2.160,
5759.03369,47.598,6837.60547,-2.160,
5759.12500,46.598,6837.69727,-2.160,
5759.21680,47.598,6837.78857,-2.160,
5759.30811,47.598,6837.88037,-1.160,
5759.39990,47.598,6837.97168,-1.160,
5759.49121,47.598,6838.06299,-2.160,
5759.58301,47.598,6838.15479,-2.160,
5759.67432,47.598,6838.24609,-2.160,
5759.76611,46.598,6838.33789,-1.160,
5759.85742,46.598,6838.42920,-2.160,
5759.94873,46.598,6838.52100,-2.160,
5760.04053,46.598,6838.61230,-1.160,
5760.13184,47.598,6838.70361,-2.160,
5760.22363,47.598,6838.79541,-2.160,
5760.31494,46.598,6838.88672,-2.160,
5760.40674,46.598,6838.97852,-1.160,
5760.49805,47.598,6839.06982,-2.160,
5760.58936,46.598,6839.16162,-1.160,
5760.68115,46.598,6839.25293,-1.160,
5760.77246,46.598,6839.34424,-1.160,
5760.86426,46.598,6839.43604,-1.160,
5760.95557,46.598,6839.52734,-1.160,
5761.04736,46.598,6839.61914,-1.160,
5761.13867,46.598,6839.71045,-2.160,
5761.22998,46.598,6839.80225,-1.160,
5761.32178,46.598,6839.89355,-2.160,
5761.41309,46.598,6839.98486,-1.160,
5761.50488,45.598,6840.07666,-2.160,
5761.59619,46.598,6840.16797,-2.160,
5761.68799,45.598,6840.25977,-2.160,
5761.77930,46.598,6840.35107,-2.160,
5761.87109,45.598,6840.44287,-2.160,
5761.96240,46.598,6840.53418,-2.160,
5762.05371,46.598,6840.62598,-2.160,
5762.14551,45.598,6840.71729,-2.160,
5762.23682,45.598,6840.80859,-1.160,
5762.32861,45.598,6840.90039,-2.160,
5762.41992,45.598,6840.99170,-2.160,
5762.51172,45.598,6841.08350,-2.160,
5762.60303,45.598,6841.17480,-2.160,
5762.69434,45.598,6841.26660,-2.160,
5762.78613,45.598,6841.35791,-2.160,
5762.87744,45.598,6841.44922,-2.160,
5762.96924,45.598,6841.54102,-2.160,
5763.06055,46.598,6841.63232,-2.160,
5763.15234,45.598,6841.72412,-2.160,
5763.24365,45.598,6841.81543,-2.160,
5763.33496,45.598,6841.90723,-2.160,
5763.42676,45.598,6841.99854,-2.160,
5763.51807,45.598,6842.08984,-2.160,
5763.60986,46.598,6842.18164,-3.160,
5763.70117,45.598,6842.27295,-2.160,
5763.79297,46.598,6842.36475,-2.160,
5763.88428,45.598,6842.45605,-2.160,
5763.97607,45.598,6842.54785,-3.160,
5764.06738,45.598,6842.63916,-3.160,
5764.15869,45.598,6842.73096,-2.160,
5764.25049,45.598,6842.82227,-3.160,
5764.34180,45.598,6842.91357,-3.160,
5764.43359,45.598,6843.00537,-4.160,
5764.52490,46.598,6843.09668,-4.160,
5764.61670,45.598,6843.18848,-3.160,
5764.70801,45.598,6843.27979,-3.160,
5764.79932,45.598,6843.37158,-3.160,
5764.89111,45.598,6843.46289,-3.160,
5764.98242,45.598,6843.55420,-3.160,
5765.07422,45.598,6843.64600,-3.160,
5765.16553,44.598,6843.73730,-2.160,
5765.25732,45.598,6843.82910,-2.160,
5765.34863,45.598,6843.92041,-2.160,
5765.43994,44.598,6844.01221,-2.160,
5765.53174,45.598,6844.10352,-2.160,
5765.62305,45.598,6844.19482,-2.160,
5765.71484,44.598,6844.28662,-2.160,
5765.80615,45.598,6844.37793,-2.160,
5765.89795,44.598,6844.46973,-2.160,
5765.98926,45.598,6844.56104,-2.160,
5766.08105,44.598,6844.65283,-2.160,
5766.17236,44.598,6844.74414,-1.160,
5766.26367,45.598,6844.83594,-1.160,
5766.35547,44.598,6844.92725,-0.160,
5766.44678,44.598,6845.01855,-0.160,
5766.53857,44.598,6845.11035,-0.160,
5766.62988,45.598,6845.20166,0.840,
5766.72168,44.598,6845.29346,1.840,
5766.81299,44.598,6845.38477,0.840,
5766.90430,44.598,6845.47656,1.840,
5766.99609,44.598,6845.56787,1.840,
5767.08740,44.598,6845.65918,1.840,
5767.17920,45.598,6845.75098,1.840,
5767.27051,45.598,6845.84229,1.840,
5767.36230,44.598,6845.93408,1.840,
5767.45361,45.598,6846.02539,0.840,
5767.54492,45.598,6846.11719,0.840,
5767.63672,45.598,6846.20850,0.840,
5767.72803,44.598,6846.29980,0.840,
5767.81982,45.598,6846.39160,0.840,
5767.91113,44.598,6846.48291,-0.160,
5768.00293,44.598,6846.57471,-0.160,
5768.09424,44.598,6846.66602,-0.160,
5768.18555,44.598,6846.75781,-1.160,
5768.27734,44.598,6846.84912,-0.160,
5768.36865,44.598,6846.94092,-1.160,
5768.46045,44.598,6847.03223,-1.160,
5768.55176,44.598,6847.12354,-1.160,
5768.64355,44.598,6847.21533,-1.160,
5768.73486,44.598,6847.30664,-1.160,
5768.82666,44.598,6847.39844,-1.160,
5768.91797,44.598,6847.48975,-1.160,
5769.00928,44.598,6847.58154,-2.160,
5769.10107,44.598,6847.67285,-2.160,
5769.19238,45.598,6847.76416,-2.160,
5769.28418,44.598,6847.85596,-2.160,
5769.37549,44.598,6847.94727,-2.160,
5769.46729,44.598,6848.03906,-1.160,
5769.55859,44.598,6848.13037,-0.160,
5769.64990,44.598,6848.22217,-2.160,
5769.74170,44.598,6848.31348,-2.160,
5769.83301,44.598,6848.40479,-1.160,
5769.92480,44.598,6848.49658,-2.160,
5770.01611,44.598,6848.58789,-2.160,
5770.10791,44.598,6848.67969,-1.160,
5770.19922,44.598,6848.77100,-2.160,
5770.29053,44.598,6848.86279,-2.160,
5770.38232,44.598,6848.95410,-2.160,
5770.47363,43.598,6849.04590,-2.160,
5770.56543,44.598,6849.13721,-2.160,
5770.65674,43.598,6849.22852,-2.160,
5770.74854,44.598,6849.32031,-2.160,
5770.83984,44.598,6849.41162,-2.160,
5770.93164,44.598,6849.50342,-2.160,
5771.02295,43.598,6849.59473,-1.160,
5771.11426,43.598,6849.68652,-2.160,
5771.20605,43.598,6849.77783,-2.160,
5771.29736,44.598,6849.86914,-1.160,
5771.38916,44.598,6849.96094,-2.160,
5771.48047,44.598,6850.05225,-2.160,
5771.57227,43.598,6850.14404,-2.160,
5771.66357,43.598,6850.23535,-2.160,
5771.75488,44.598,6850.32715,-2.160,
5771.84668,44.598,6850.41846,-2.160,
5771.93799,43.598,6850.50977,-2.160,
5772.02979,43.598,6850.60156,-2.160,
5772.12109,44.598,6850.69287,-2.160,
5772.21289,43.598,6850.78467,-2.160,
5772.30420,43.598,6850.87598,-2.160,
5772.39551,43.598,6850.96777,-2.160,
5772.48730,43.598,6851.05908,-1.160,
5772.57861,43.598,6851.15088,-2.160,
5772.67041,43.598,6851.24219,-2.160,
5772.76172,43.598,6851.33350,-2.160,
5772.85352,43.598,6851.42529,-1.160,
5772.94482,43.598,6851.51660,-2.160,
5773.03662,43.598,6851.60840,-2.160,
5773.12793,43.598,6851.69971,-1.160,
5773.21924,43.598,6851.79150,-2.160,
5773.31104,44.598,6851.88281,-2.160,
5773.40234,44.598,6851.97412,-2.160,
5773.49414,43.598,6852.06592,-2.160,
5773.58545,43.598,6852.15723,-2.160,
5773.67725,43.598,6852.24902,-2.160,
5773.76855,43.598,6852.34033,-2.160,
5773.85986,43.598,6852.43213,-2.160,
5773.95166,43.598,6852.52344,-2.160,
5774.04297,43.598,6852.61475,-2.160,
5774.13477,43.598,6852.70654,-2.160,
5774.22607,43.598,6852.79785,-2.160,
5774.31787,43.598,6852.88965,-2.160,
5774.40918,43.598,6852.98096,-2.160,
5774.50049,43.598,6853.07275,-2.160,
5774.59229,43.598,6853.16406,-2.160,
5774.68359,42.598,6853.25537,-2.160,
5774.77539,43.598,6853.34717,-2.160,
5774.86670,43.598,6853.43848,-2.160,
5774.95850,43.598,6853.53027,-2.160,
5775.04980,43.598,6853.62158,-2.160,
5775.14160,43.598,6853.71338,-2.160,
5775.23291,42.598,6853.80469,-2.160,
5775.32422,43.598,6853.89648,-2.160,
5775.41602,43.598,6853.98779,-2.160,
5775.50732,43.598,6854.07910,-2.160,
5775.59912,42.598,6854.17090,-2.160,
5775.69043,43.598,6854.26221,-2.160,
5775.78223,42.598,6854.35400,-2.160,
5775.87354,42.598,6854.44531,-2.160,
5775.96484,42.598,6854.53711,-2.160,
5776.05664,42.598,6854.62842,-2.160,
5776.14795,42.598,6854.71973,-2.160,
5776.23975,42.598,6854.81152,-2.160,
5776.33105,42.598,6854.90283,-2.160,
5776.42285,42.598,6854.99463,-2.160,
5776.51416,42.598,6855.08594,-2.160,
5776.60547,42.598,6855.17773,-2.160,
5776.69727,42.598,6855.26904,-2.160,
5776.78857,42.598,6855.36035,-2.160,
5776.88037,42.598,6855.45215,-1.160,
5776.97168,42.598,6855.54346,-2.160,
5777.06348,42.598,6855.63525,-2.160,
5777.15479,42.598,6855.72656,-2.160,
5777.24658,42.598,6855.81836,-2.160,
5777.33789,42.598,6855.90967,-2.160,
5777.42920,42.598,6856.00146,-2.160,
5777.52100,42.598,6856.09277,-1.160,
5777.61230,43.598,6856.18408,-2.160,
5777.70410,43.598,6856.27588,-2.160,
5777.79541,42.598,6856.36719,-2.160,
5777.88721,43.598,6856.45898,-1.160,
5777.97852,43.598,6856.55029,-2.160,
5778.06982,43.598,6856.64209,-2.160,
5778.16162,43.598,6856.73340,-2.160,
5778.25293,43.598,6856.82471,-2.160,
5778.34473,42.598,6856.91650,-1.160,
5778.43604,42.598,6857.00781,-1.160,
5778.52783,42.598,6857.09961,-2.160,
5778.61914,41.598,6857.19092,-2.160,
5778.71045,41.598,6857.28271,-1.160,
5778.80225,42.598,6857.37402,-1.160,
5778.89355,42.598,6857.46533,-2.160,
5778.98535,41.598,6857.55713,-2.160,
5779.07666,42.598,6857.64844,-1.160,
5779.16846,41.598,6857.74023,-2.160,
5779.25977,41.598,6857.83154,-2.160,
5779.35156,42.598,6857.92334,-2.160,
5779.44287,42.598,6858.01465,-2.160,
5779.53418,41.598,6858.10645,-2.160,
5779.62598,42.598,6858.19775,-2.160,
5779.71729,42.598,6858.28906,-2.160,
5779.80908,42.598,6858.38086,-1.160,
5779.90039,42.598,6858.47217,-1.160,
5779.99219,41.598,6858.56396,-1.160,
5780.08350,41.598,6858.65527,-2.160,
5780.17480,42.598,6858.74707,-2.160,
5780.26660,42.598,6858.83838,-1.160,
5780.35791,42.598,6858.92969,-2.160,
5780.44971,42.598,6859.02148,-2.160,
5780.54102,42.598,6859.11279,-2.160,
5780.63281,42.598,6859.20459,-2.160,
5780.72412,42.598,6859.29590,-2.160,
5780.81543,41.598,6859.38770,-2.160,
5780.90723,42.598,6859.47900,-2.160,
5780.99854,42.598,6859.57031,-2.160,
5781.09033,42.598,6859.66211,-2.160,
5781.18164,42.598,6859.75342,-2.160,
5781.27344,42.598,6859.84521,-1.160,
5781.36475,41.598,6859.93652,-2.160,
5781.45605,41.598,6860.02832,-1.160,
5781.54785,42.598,6860.11963,-2.160,
5781.63916,42.598,6860.21143,-2.160,
5781.73096,41.598,6860.30273,-2.160,
5781.82227,41.598,6860.39404,-2.160,
5781.91406,41.598,6860.48584,-2.160,
5782.00537,42.598,6860.57715,-2.160,
5782.09717,42.598,6860.66895,-2.160,
5782.18848,41.598,6860.76025,-1.160,
5782.27979,42.598,6860.85205,-1.160,
5782.37158,41.598,6860.94336,-0.160,
5782.46289,41.598,6861.03467,-0.160,
5782.55469,42.598,6861.12646,-0.160,
5782.64600,42.598,6861.21777,-1.160,
5782.73779,42.598,6861.30957,-0.160,
5782.82910,41.598,6861.40088,-0.160,
5782.92041,41.598,6861.49268,-1.160,
5783.01221,41.598,6861.58398,-1.160,
5783.10352,41.598,6861.67529,-1.160,
5783.19531,41.598,6861.76709,-1.160,
5783.28662,41.598,6861.85840,-1.160,
5783.37842,41.598,6861.95020,-1.160,
5783.46973,42.598,6862.04150,-2.160,
5783.56104,42.598,6862.13330,-2.160,
5783.65283,41.598,6862.22461,-2.160,
5783.74414,42.598,6862.31641,-2.160,
5783.83594,41.598,6862.40771,-2.160,
5783.92725,41.598,6862.49902,-1.160,
5784.01904,41.598,6862.59082,-2.160,
5784.11035,41.598,6862.68213,-2.160,
5784.20215,41.598,6862.77393,-1.160,
5784.29346,41.598,6862.86523,-2.160,
5784.38477,41.598,6862.95703,-2.160,
5784.47656,41.598,6863.04834,-2.160,
5784.56787,41.598,6863.13965,-4.160,
5784.65967,41.598,6863.23145,-4.160,
5784.75098,41.598,6863.32275,-5.160,
5784.84277,41.598,6863.41455,-6.160,
5784.93408,41.598,6863.50586,-6.160,
5785.02539,41.598,6863.59766,-6.160,
5785.11719,41.598,6863.68896,-6.160,
5785.20850,41.598,6863.78027,-6.160,
5785.30029,42.598,6863.87207,-6.160,
5785.39160,41.598,6863.96338,-5.160,
5785.48340,40.598,6864.05518,-4.160,
5785.57471,41.598,6864.14648,-4.160,
5785.66602,41.598,6864.23828,-3.160,
5785.75781,41.598,6864.32959,-3.160,
5785.84912,41.598,6864.42139,-2.160,
5785.94092,41.598,6864.51270,-2.160,
5786.03223,41.598,6864.60400,-2.160,
5786.12402,41.598,6864.69580,-2.160,
5786.21533,41.598,6864.78711,-2.160,
5786.30713,41.598,6864.87891,-2.160,
5786.39844,41.598,6864.97021,-2.160,
5786.48975,41.598,6865.06201,-2.160,
5786.58154,41.598,6865.15332,-2.160,
5786.67285,40.598,6865.24463,-1.160,
5786.76465,41.598,6865.33643,-2.160,
5786.85596,41.598,6865.42773,-2.160,
5786.94775,41.598,6865.51953,-2.160,
5787.03906,40.598,6865.61084,-2.160,
5787.13037,41.598,6865.70264,-1.160,
5787.22217,40.598,6865.79395,-2.160,
5787.31348,40.598,6865.88525,-1.160,
5787.40527,40.598,6865.97705,-2.160,
5787.49658,40.598,6866.06836,-2.160,
5787.58838,41.598,6866.16016,-1.160,
5787.67969,40.598,6866.25146,-2.160,
5787.77100,40.598,6866.34326,-2.160,
5787.86279,40.598,6866.43457,-2.160,
5787.95410,40.598,6866.52588,-2.160,
5788.04590,40.598,6866.61768,-2.160,
5788.13721,40.598,6866.70898,-2.160,
5788.22900,40.598,6866.80078,-2.160,
5788.32031,40.598,6866.89209,-2.160,
5788.41211,40.598,6866.98389,-2.160,
5788.50342,40.598,6867.07520,-2.160,
5788.59473,40.598,6867.16699,-1.160,
5788.68652,40.598,6867.25830,-2.160,
5788.77783,40.598,6867.34961,-2.160,
5788.86963,40.598,6867.44141,-2.160,
5788.96094,40.598,6867.53271,-2.160,
5789.05273,40.598,6867.62451,-2.160,
5789.14404,40.598,6867.71582,-1.160,
5789.23535,40.598,6867.80762,-2.160,
5789.32715,40.598,6867.89893,-2.160,
5789.41846,40.598,6867.99023,-2.160,
5789.51025,40.598,6868.08203,-2.160,
5789.60156,40.598,6868.17334,-2.160,
5789.69336,40.598,6868.26514,-2.160,
5789.78467,40.598,6868.35645,-2.160,
5789.87598,40.598,6868.44824,-2.160,
5789.96777,40.598,6868.53955,-2.160,
5790.05908,40.598,6868.63086,-1.160,
5790.15088,40.598,6868.72266,-2.160,
5790.24219,40.598,6868.81396,-2.160,
5790.33398,40.598,6868.90576,-1.160,
5790.42529,40.598,6868.99707,-1.160,
5790.51709,40.598,6869.08887,-2.160,
5790.60840,39.598,6869.18018,-1.160,
5790.69971,39.598,6869.27197,-1.160,
5790.79150,40.598,6869.36328,-2.160,
5790.88281,40.598,6869.45459,-1.160,
5790.97461,39.598,6869.54639,-1.160,
5791.06592,40.598,6869.63770,-2.160,
5791.15771,40.598,6869.72949,-1.160,
5791.24902,39.598,6869.82080,-2.160,
5791.34033,40.598,6869.91260,-2.160,
5791.43213,40.598,6870.00391,-2.160,
5791.52344,39.598,6870.09521,-1.160,
5791.61523,39.598,6870.18701,-2.160,
5791.70654,40.598,6870.27832,-2.160,
5791.79834,39.598,6870.37012,-1.160,
5791.88965,39.598,6870.46143,-1.160,
5791.98096,40.598,6870.55322,-2.160,
5792.07275,39.598,6870.64453,-2.160,
5792.16406,39.598,6870.73584,-1.160,
5792.25586,40.598,6870.82764,-2.160,
5792.34717,40.598,6870.91895,-2.160,
5792.43896,39.598,6871.01074,-2.160,
5792.53027,40.598,6871.10205,-2.160,
5792.62158,39.598,6871.19385,-2.160,
5792.71338,39.598,6871.28516,-2.160,
5792.80469,40.598,6871.37695,-2.160,
5792.89648,40.598,6871.46826,-2.160,
5792.98779,40.598,6871.55957,-2.160,
5793.07959,39.598,6871.65137,-2.160,
5793.17090,39.598,6871.74268,-2.160,
5793.26270,39.598,6871.83447,-2.160,
5793.35400,39.598,6871.92578,-2.160,
5793.44531,39.598,6872.01758,-2.160,
5793.53711,39.598,6872.10889,-1.160,
5793.62842,39.598,6872.20020,-2.160,
5793.72021,39.598,6872.29199,-2.160,
5793.81152,40.598,6872.38330,-2.160,
5793.90332,40.598,6872.47510,-2.160,
5793.99463,39.598,6872.56641,-2.160,
5794.08594,39.598,6872.65820,-2.160,
5794.17773,40.598,6872.74951,-2.160,
5794.26904,40.598,6872.84082,-2.160,
5794.36084,39.598,6872.93262,-2.160,
5794.45215,39.598,6873.02393,-1.160,
5794.54395,39.598,6873.11572,-2.160,
5794.63525,39.598,6873.20703,-1.160,
5794.72656,39.598,6873.29883,-2.160,
5794.81836,39.598,6873.39014,-2.160,
5794.90967,39.598,6873.48193,-1.160,
5795.00146,39.598,6873.57324,-2.160,
5795.09277,40.598,6873.66455,-2.160,
5795.18457,39.598,6873.75635,-2.160,
5795.27588,40.598,6873.84766,-2.160,
5795.36768,39.598,6873.93945,-2.160,
5795.45898,39.598,6874.03076,-2.160,
5795.55029,39.598,6874.12256,-2.160,
5795.64209,39.598,6874.21387,-1.160,
5795.73340,39.598,6874.30518,-2.160,
5795.82520,39.598,6874.39697,-2.160,
5795.91650,39.598,6874.48828,-1.160,
5796.00830,39.598,6874.58008,-2.160,
5796.09961,39.598,6874.67139,-1.160,
5796.19092,38.598,6874.76318,-2.160,
5796.28271,38.598,6874.85449,-1.160,
5796.37402,39.598,6874.94580,-2.160,
5796.46582,39.598,6875.03760,-1.160,
5796.55713,39.598,6875.12891,-1.160,
5796.64893,39.598,6875.22070,-1.160,
5796.74023,39.598,6875.31201,-2.160,
5796.83154,39.598,6875.40381,-2.160,
5796.92334,39.598,6875.49512,-2.160,
5797.01465,38.598,6875.58691,-2.160,
5797.10645,37.598,6875.67822,-2.160,
5797.19775,38.598,6875.76953,-2.160,
5797.28955,38.598,6875.86133,-2.160,
5797.38086,38.598,6875.95264,-2.160,
5797.47266,38.598,6876.04443,-2.160,
5797.56396,38.598,6876.13574,-2.160,
5797.65527,38.598,6876.22754,-2.160,
5797.74707,38.598,6876.31885,-2.160,
5797.83838,38.598,6876.41016,-2.160,
5797.93018,38.598,6876.50195,-2.160,
5798.02148,39.598,6876.59326,-2.160,
5798.11328,38.598,6876.68506,-2.160,
5798.20459,39.598,6876.77637,-2.160,
5798.29590,39.598,6876.86816,-2.160,
5798.38770,38.598,6876.95947,-2.160,
5798.47900,39.598,6877.05078,-2.160,
5798.57080,38.598,6877.14258,-2.160,
5798.66211,39.598,6877.23389,-2.160,
5798.75391,38.598,6877.32568,-2.160,
5798.84521,38.598,6877.41699,-1.160,
5798.93652,38.598,6877.50879,-1.160,
5799.02832,38.598,6877.60010,-2.160,
5799.11963,38.598,6877.69141,-2.160,
5799.21143,38.598,6877.78320,-2.160,
5799.30273,38.598,6877.87451,-2.160,
5799.39453,38.598,6877.96631,-2.160,
5799.48584,38.598,6878.05762,-2.160,
5799.57764,38.598,6878.14941,-1.160,
5799.66895,39.598,6878.24072,-2.160,
5799.76025,38.598,6878.33252,-2.160,
5799.85205,38.598,6878.42383,-2.160,
5799.94336,38.598,6878.51514,-2.160,
5800.03516,38.598,6878.60693,-3.160,
5800.12646,38.598,6878.69824,-3.160,
5800.21826,37.598,6878.79004,-3.160,
5800.30957,38.598,6878.88135,-2.160,
5800.40088,38.598,6878.97314,-3.160,
5800.49268,38.598,6879.06445,-4.160,
5800.58398,38.598,6879.15576,-3.160,
5800.67578,38.598,6879.24756,-4.160,
5800.76709,38.598,6879.33887,-4.160,
5800.85889,38.598,6879.43066,-3.160,
5800.95020,38.598,6879.52197,-3.160,
5801.04150,38.598,6879.61377,-3.160,
5801.13330,38.598,6879.70508,-3.160,
5801.22461,38.598,6879.79639,-3.160,
5801.31641,38.598,6879.88818,-3.160,
5801.40771,38.598,6879.97949,-3.160,
5801.49951,38.598,6880.07129,-3.160,
5801.59082,38.598,6880.16260,-3.160,
5801.68262,38.598,6880.25439,-3.160,
5801.77393,38.598,6880.34570,-2.160,
5801.86523,38.598,6880.43750,-2.160,
5801.95703,38.598,6880.52881,-2.160,
5802.04834,38.598,6880.62012,-2.160,
5802.14014,37.598,6880.71191,-2.160,
5802.23145,38.598,6880.80322,-2.160,
5802.32324,37.598,6880.89502,-2.160,
5802.41455,38.598,6880.98633,-1.160,
5802.50586,37.598,6881.07813,-1.160,
5802.59766,38.598,6881.16943,-0.160,
5802.68896,38.598,6881.26074,-0.160,
5802.78076,38.598,6881.35254,0.840,
5802.87207,37.598,6881.44385,0.840,
5802.96387,37.598,6881.53564,1.840,
5803.05518,38.598,6881.62695,1.840,
5803.14648,37.598,6881.71875,1.840,
5803.23828,38.598,6881.81006,2.840,
5803.32959,37.598,6881.90137,1.840,
5803.42139,38.598,6881.99316,0.840,
5803.51270,37.598,6882.08447,0.840,
5803.60449,38.598,6882.17627,0.840,
5803.69580,38.598,6882.26758,0.840,
5803.78760,37.598,6882.35938,0.840,
5803.87891,38.598,6882.45068,0.840,
5803.97021,38.598,6882.54248,-0.160,
5804.06201,38.598,6882.63379,-0.160,
5804.15332,37.598,6882.72510,-0.160,
5804.24512,37.598,6882.81689,-1.160,
5804.33643,37.598,6882.90820,-1.160,
5804.42822,37.598,6883.00000,-1.160,
5804.51953,37.598,6883.09131,-0.160,
5804.61084,38.598,6883.18311,-1.160,
5804.70264,37.598,6883.27441,-0.160,
5804.79395,37.598,6883.36572,-1.160,
5804.88574,37.598,6883.45752,-2.160,
5804.97705,37.598,6883.54883,-1.160,
5805.06885,37.598,6883.64063,-1.160,
5805.16016,37.598,6883.73193,-1.160,
5805.25146,37.598,6883.82373,-1.160,
5805.34326,37.598,6883.91504,-1.160,
5805.43457,37.598,6884.00635,-1.160,
5805.52637,38.598,6884.09814,-1.160,
5805.61768,37.598,6884.18945,-1.160,
5805.70947,37.598,6884.28125,-1.160,
5805.80078,37.598,6884.37256,-1.160,
5805.89209,37.598,6884.46436,-2.160,
5805.98389,37.598,6884.55566,-1.160,
5806.07520,37.598,6884.64746,-2.160,
5806.16699,37.598,6884.73877,-1.160,
5806.25830,37.598,6884.83008,-2.160,
5806.35010,37.598,6884.92188,-1.160,
5806.44141,37.598,6885.01318,-2.160,
5806.53320,36.598,6885.10498,-1.160,
5806.62451,37.598,6885.19629,-2.160,
5806.71582,37.598,6885.28809,-2.160,
5806.80762,37.598,6885.37939,-2.160,
5806.89893,36.598,6885.47070,-2.160,
5806.99072,37.598,6885.56250,-2.160,
5807.08203,37.598,6885.65381,-2.160,
5807.17383,37.598,6885.74561,-2.160,
5807.26514,37.598,6885.83691,-2.160,
5807.35645,37.598,6885.92871,-2.160,
5807.44824,36.598,6886.02002,-2.160,
5807.53955,37.598,6886.11133,-2.160,
5807.63135,37.598,6886.20313,-2.160,
5807.72266,37.598,6886.29443,-2.160,
5807.81445,36.598,6886.38623,-2.160,
5807.90576,37.598,6886.47754,-2.160,
5807.99707,36.598,6886.56934,-2.160,
5808.08887,37.598,6886.66064,-2.160,
5808.18018,36.598,6886.75244,-2.160,
5808.27197,36.598,6886.84375,-2.160,
5808.36328,36.598,6886.93506,-2.160,
5808.45508,37.598,6887.02686,-2.160,
5808.54639,37.598,6887.11816,-2.160,
5808.63818,37.598,6887.20996,-2.160,
5808.72949,37.598,6887.30127,-2.160,
5808.82080,36.598,6887.39307,-2.160,
5808.91260,37.598,6887.48438,-2.160,
5809.00391,36.598,6887.57568,-2.160,
5809.09570,36.598,6887.66748,-1.160,
5809.18701,37.598,6887.75879,-2.160,
5809.27881,36.598,6887.85059,-2.160,
5809.37012,36.598,6887.94189,-2.160,
5809.46143,36.598,6888.03369,-2.160,
5809.55322,36.598,6888.12500,-2.160,
5809.64453,36.598,6888.21631,-2.160,
5809.73633,36.598,6888.30811,-1.160,
5809.82764,36.598,6888.39941,-1.160,
5809.91943,37.598,6888.49121,-2.160,
5810.01074,36.598,6888.58252,-1.160,
5810.10205,36.598,6888.67432,-2.160,
5810.19385,36.598,6888.76563,-2.160,
5810.28516,36.598,6888.85742,-2.160,
5810.37695,36.598,6888.94873,-2.160,
5810.46826,36.598,6889.04004,-2.160,
5810.56006,36.598,6889.13184,-2.160,
5810.65137,36.598,6889.22314,-2.160,
5810.74316,36.598,6889.31494,-2.160,
5810.83447,36.598,6889.40625,-2.160,
5810.92578,36.598,6889.49805,-2.160,
5811.01758,36.598,6889.58936,-2.160,
5811.10889,36.598,6889.68066,-2.160,
5811.20068,36.598,6889.77246,-1.160,
5811.29199,36.598,6889.86377,-1.160,
5811.38379,37.598,6889.95557,-2.160,
5811.47510,37.598,6890.04688,-2.160,
5811.56641,36.598,6890.13867,-2.160,
5811.65820,36.598,6890.22998,-2.160,
5811.74951,36.598,6890.32129,-2.160,
5811.84131,36.598,6890.41309,-2.160,
5811.93262,36.598,6890.50439,-2.160,
5812.02441,37.598,6890.59619,-1.160,
5812.11572,36.598,6890.68750,-1.160,
5812.20703,36.598,6890.77930,-1.160,
5812.29883,36.598,6890.87061,-1.160,
5812.39014,36.598,6890.96191,-2.160,
5812.48193,36.598,6891.05371,-1.160,
5812.57324,36.598,6891.14502,-2.160,
5812.66504,36.598,6891.23682,-2.160,
5812.75635,35.598,6891.32813,-1.160,
5812.84814,37.598,6891.41992,-1.160,
5812.93945,36.598,6891.51123,-1.160,
5813.03076,36.598,6891.60303,-1.160,
5813.12256,36.598,6891.69434,-1.160,
5813.21387,36.598,6891.78564,-1.160,
5813.30566,36.598,6891.87744,-1.160,
5813.39697,36.598,6891.96875,-1.160,
5813.48877,36.598,6892.06055,-1.160,
5813.58008,36.598,6892.15186,-2.160,
5813.67139,35.598,6892.24365,-1.160,
5813.76318,36.598,6892.33496,-1.160,
5813.85449,36.598,6892.42627,-1.160,
5813.94629,35.598,6892.51807,-1.160,
5814.03760,36.598,6892.60938,-1.160,
5814.12939,36.598,6892.70117,-1.160,
5814.22070,35.598,6892.79248,-2.160,
5814.31201,36.598,6892.88428,-2.160,
5814.40381,36.598,6892.97559,-1.160,
5814.49512,36.598,6893.06689,-1.160,
5814.58691,35.598,6893.15869,-1.160,
5814.67822,35.598,6893.25000,-2.160,
5814.77002,36.598,6893.34180,-2.160,
5814.86133,36.598,6893.43311,-1.160,
5814.95313,35.598,6893.52490,-1.160,
5815.04443,36.598,6893.61621,-2.160,
5815.13574,35.598,6893.70801,-1.160,
5815.22754,35.598,6893.79932,-1.160,
5815.31885,35.598,6893.89063,-1.160,
5815.41064,35.598,6893.98242,-2.160,
5815.50195,35.598,6894.07373,-1.160,
5815.59375,35.598,6894.16553,-2.160,
5815.68506,35.598,6894.25684,-1.160,
5815.77637,36.598,6894.34863,-2.160,
5815.86816,36.598,6894.43994,-2.160,
5815.95947,36.598,6894.53125,-2.160,
5816.05127,36.598,6894.62305,-1.160,
5816.14258,36.598,6894.71436,-1.160,
5816.23438,35.598,6894.80615,-2.160,
5816.32568,36.598,6894.89746,-2.160,
5816.41699,35.598,6894.98926,-1.160,
5816.50879,35.598,6895.08057,-1.160,
5816.60010,35.598,6895.17188,-1.160,
5816.69189,35.598,6895.26367,-1.160,
5816.78320,35.598,6895.35498,-1.160,
5816.87500,35.598,6895.44678,-2.160,
5816.96631,35.598,6895.53809,-2.160,
5817.05811,35.598,6895.62988,-1.160,
5817.14941,35.598,6895.72119,-1.160,
5817.24072,35.598,6895.81299,-1.160,
5817.33252,35.598,6895.90430,-2.160,
5817.42383,35.598,6895.99561,-2.160,
5817.51563,35.598,6896.08740,-2.160,
5817.60693,35.598,6896.17871,-2.160,
5817.69873,34.598,6896.27051,-2.160,
5817.79004,34.598,6896.36182,-1.160,
5817.88135,34.598,6896.45361,-1.160,
5817.97314,35.598,6896.54492,-2.160,
5818.06445,35.598,6896.63623,-1.160,
5818.15625,35.598,6896.72803,-1.160,
5818.24756,34.598,6896.81934,-1.160,
5818.33936,35.598,6896.91113,-0.160,
5818.43066,34.598,6897.00244,0.840,
5818.52197,35.598,6897.09424,0.840,
5818.61377,35.598,6897.18555,0.840,
5818.70508,35.598,6897.27686,0.840,
5818.79688,35.598,6897.36865,0.840,
5818.88818,35.598,6897.45996,0.840,
5818.97998,35.598,6897.55176,0.840,
5819.07129,35.598,6897.64307,0.840,
5819.16260,35.598,6897.73486,0.840,
5819.25439,35.598,6897.82617,0.840,
5819.34570,35.598,6897.91797,0.840,
5819.43750,34.598,6898.00928,-0.160,
5819.52881,34.598,6898.10059,-0.160,
5819.62061,35.598,6898.19238,-0.160,
5819.71191,34.598,6898.28369,-0.160,
5819.80371,34.598,6898.37549,-1.160,
5819.89502,34.598,6898.46680,-1.160,
5819.98633,35.598,6898.55859,-1.160,
5820.07813,35.598,6898.64990,-1.160,
5820.16943,35.598,6898.74121,-2.160,
5820.26123,35.598,6898.83301,-2.160,
5820.35254,34.598,6898.92432,-1.160,
5820.44434,34.598,6899.01611,-2.160,
5820.53564,34.598,6899.10742,-2.160,
5820.62695,35.598,6899.19922,-2.160,
5820.71875,34.598,6899.29053,-3.160,
5820.81006,35.598,6899.38184,-3.160,
5820.90186,35.598,6899.47363,-5.160,
5820.99316,34.598,6899.56494,-5.160,
5821.08496,34.598,6899.65674,-5.160,
5821.17627,34.598,6899.74805,-6.160,
5821.26758,34.598,6899.83984,-6.160,
5821.35938,34.598,6899.93115,-5.160,
5821.45068,34.598,6900.02295,-5.160,
5821.54248,34.598,6900.11426,-5.160,
5821.63379,35.598,6900.20557,-4.160,
5821.72559,34.598,6900.29736,-4.160,
5821.81689,34.598,6900.38867,-4.160,
5821.90869,34.598,6900.48047,-3.160,
5822.00000,34.598,6900.57178,-3.160,
5822.09131,34.598,6900.66357,-3.160,
5822.18311,34.598,6900.75488,-2.160,
5822.27441,34.598,6900.84619,-2.160,
5822.36621,34.598,6900.93799,-2.160,
5822.45752,34.598,6901.02930,-2.160,
5822.54932,34.598,6901.12109,-2.160,
5822.64063,34.598,6901.21240,-2.160,
5822.73193,34.598,6901.30420,-2.160,
5822.82373,34.598,6901.39551,-2.160,
5822.91504,34.598,6901.48682,-2.160,
5823.00684,34.598,6901.57861,-2.160,
5823.09814,34.598,6901.66992,-2.160,
5823.18994,34.598,6901.76172,-2.160,
5823.28125,34.598,6901.85303,-2.160,
5823.37256,34.598,6901.94482,-2.160,
5823.46436,34.598,6902.03613,-1.160,
5823.55566,34.598,6902.12744,-2.160,
5823.64746,34.598,6902.21924,-1.160,
5823.73877,34.598,6902.31055,-1.160,
5823.83057,34.598,6902.40234,-2.160,
5823.92188,34.598,6902.49365,-2.160,
5824.01367,34.598,6902.58545,-1.160,
5824.10498,34.598,6902.67676,-1.160,
5824.19629,34.598,6902.76855,-1.160,
5824.28809,34.598,6902.85986,-1.160,
5824.37939,34.598,6902.95117,-2.160,
5824.47119,34.598,6903.04297,-1.160,
5824.56250,35.598,6903.13428,-2.160,
5824.65430,34.598,6903.22607,-2.160,
5824.74561,34.598,6903.31738,-1.160,
5824.83691,34.598,6903.40918,-2.160,
5824.92871,34.598,6903.50049,-2.160,
5825.02002,34.598,6903.59180,-1.160,
5825.11182,34.598,6903.68359,-2.160,
5825.20313,34.598,6903.77490,-1.160,
5825.29492,34.598,6903.86670,-2.160,
5825.38623,34.598,6903.95801,-2.160,
5825.47754,34.598,6904.04980,-2.160,
5825.56934,33.598,6904.14111,-2.160,
5825.66064,34.598,6904.23242,-2.160,
5825.75244,34.598,6904.32422,-2.160,
5825.84375,34.598,6904.41553,-2.160,
5825.93555,33.598,6904.50732,-2.160,
5826.02686,34.598,6904.59863,-2.160,
5826.11865,34.598,6904.69043,-2.160,
5826.20996,33.598,6904.78174,-2.160,
5826.30127,34.598,6904.87354,-2.160,
5826.39307,34.598,6904.96484,-2.160,
5826.48438,33.598,6905.05615,-2.160,
5826.57617,34.598,6905.14795,-2.160,
5826.66748,34.598,6905.23926,-1.160,
5826.75928,33.598,6905.33105,-2.160,
5826.85059,33.598,6905.42236,-2.160,
5826.94189,34.598,6905.51416,-2.160,
5827.03369,33.598,6905.60547,-2.160,
5827.12500,33.598,6905.69678,-2.160,
5827.21680,34.598,6905.78857,-1.160,
5827.30811,34.598,6905.87988,-2.160,
5827.39990,33.598,6905.97168,-1.160,
5827.49121,34.598,6906.06299,-1.160,
5827.58252,34.598,6906.15479,-1.160,
5827.67432,34.598,6906.24609,-2.160,
5827.76563,34.598,6906.33740,-2.160,
5827.85742,34.598,6906.42920,-2.160,
5827.94873,34.598,6906.52051,-2.160,
5828.04053,34.598,6906.61230,-2.160,
5828.13184,33.598,6906.70361,-1.160,
5828.22363,34.598,6906.79541,-2.160,
5828.31494,33.598,6906.88672,-2.160,
5828.40625,33.598,6906.97852,-2.160,
5828.49805,33.598,6907.06982,-2.160,
5828.58936,33.598,6907.16113,-1.160,
5828.68115,33.598,6907.25293,-2.160,
5828.77246,33.598,6907.34424,-2.160,
5828.86426,33.598,6907.43604,-2.160,
5828.95557,34.598,6907.52734,-2.160,
5829.04688,33.598,6907.61914,-2.160,
5829.13867,34.598,6907.71045,-2.160,
5829.22998,33.598,6907.80176,-2.160,
5829.32178,33.598,6907.89355,-2.160,
5829.41309,33.598,6907.98486,-2.160,
5829.50488,33.598,6908.07666,-2.160,
5829.59619,33.598,6908.16797,-1.160,
5829.68750,33.598,6908.25977,-2.160,
5829.77930,33.598,6908.35107,-2.160,
5829.87061,33.598,6908.44238,-2.160,
5829.96240,33.598,6908.53418,-2.160,
5830.05371,33.598,6908.62549,-1.160,
5830.14551,33.598,6908.71729,-2.160,
5830.23682,33.598,6908.80859,-1.160,
5830.32813,33.598,6908.90039,-1.160,
5830.41992,33.598,6908.99170,-2.160,
5830.51123,33.598,6909.08350,-2.160,
5830.60303,33.598,6909.17480,-1.160,
5830.69434,33.598,6909.26611,-2.160,
5830.78613,33.598,6909.35791,-2.160,
5830.87744,33.598,6909.44922,-2.160,
5830.96924,33.598,6909.54102,-2.160,
5831.06055,33.598,6909.63232,-1.160,
5831.15186,33.598,6909.72412,-2.160,
5831.24365,33.598,6909.81543,-2.160,
5831.33496,33.598,6909.90674,-2.160,
5831.42676,33.598,6909.99854,-2.160,
5831.51807,33.598,6910.08984,-2.160,
5831.60986,33.598,6910.18164,-2.160,
5831.70117,33.598,6910.27295,-2.160,
5831.79248,33.598,6910.36475,-2.160,
5831.88428,33.598,6910.45605,-2.160,
5831.97559,33.598,6910.54736,-2.160,
5832.06738,33.598,6910.63916,-2.160,
5832.15869,33.598,6910.73047,-2.160,
5832.25049,33.598,6910.82227,-2.160,
5832.34180,33.598,6910.91357,-2.160,
5832.43311,33.598,6911.00537,-1.160,
5832.52490,33.598,6911.09668,-1.160,
5832.61621,33.598,6911.18848,-2.160,
5832.70801,33.598,6911.27979,-2.160,
5832.79932,33.598,6911.37109,-1.160,
5832.89111,33.598,6911.46289,-2.160,
5832.98242,32.598,6911.55420,-2.160,
5833.07422,33.598,6911.64600,-1.160,
5833.16553,32.598,6911.73730,-1.160,
5833.25684,32.598,6911.82910,-1.160,
5833.34863,33.598,6911.92041,-2.160,
5833.43994,32.598,6912.01172,-2.160,
5833.53174,32.598,6912.10352,-2.160,
5833.62305,32.598,6912.19482,-1.160,
5833.71484,33.598,6912.28662,-1.160,
5833.80615,32.598,6912.37793,-2.160,
5833.89746,32.598,6912.46973,-1.160,
5833.98926,33.598,6912.56104,-0.160,
5834.08057,33.598,6912.65234,-1.160,
5834.17236,32.598,6912.74414,-1.160,
5834.26367,33.598,6912.83545,-1.160,
5834.35547,33.598,6912.92725,-1.160,
5834.44678,33.598,6913.01855,-1.160,
5834.53809,33.598,6913.11035,-2.160,
5834.62988,34.598,6913.20166,-1.160,
5834.72119,33.598,6913.29346,-2.160,
5834.81299,33.598,6913.38477,-2.160,
5834.90430,33.598,6913.47607,-1.160,
5834.99609,33.598,6913.56787,-2.160,
5835.08740,32.598,6913.65918,-2.160,
5835.17920,33.598,6913.75098,-2.160,
5835.27051,32.598,6913.84229,-2.160,
5835.36182,33.598,6913.93408,-2.160,
5835.45361,32.598,6914.02539,-1.160,
5835.54492,32.598,6914.11670,-1.160,
5835.63672,32.598,6914.20850,-2.160,
5835.72803,32.598,6914.29980,-2.160,
5835.81982,33.598,6914.39160,-2.160,
5835.91113,32.598,6914.48291,-2.160,
5836.00244,31.598,6914.57471,-2.160,
5836.09424,32.598,6914.66602,-1.160,
5836.18555,32.598,6914.75732,-1.160,
5836.27734,33.598,6914.84912,-2.160,
5836.36865,32.598,6914.94043,-1.160,
5836.46045,32.598,6915.03223,-2.160,
5836.55176,32.598,6915.12354,-2.160,
5836.64307,32.598,6915.21533,-2.160,
5836.73486,32.598,6915.30664,-2.160,
5836.82617,32.598,6915.39795,-2.160,
5836.91797,32.598,6915.48975,-1.160,
5837.00928,32.598,6915.58105,-1.160,
5837.10107,32.598,6915.67285,-2.160,
5837.19238,32.598,6915.76416,-2.160,
5837.28418,32.598,6915.85596,-1.160,
5837.37549,32.598,6915.94727,-2.160,
5837.46680,32.598,6916.03906,-2.160,
5837.55859,32.598,6916.13037,-2.160,
5837.64990,32.598,6916.22168,-1.160,
5837.74170,33.598,6916.31348,-2.160,
5837.83301,32.598,6916.40479,-2.160,
5837.92480,32.598,6916.49658,-2.160,
5838.01611,32.598,6916.58789,-2.160,
5838.10742,32.598,6916.67969,-2.160,
5838.19922,32.598,6916.77100,-2.160,
5838.29053,32.598,6916.86230,-2.160,
5838.38232,32.598,6916.95410,-2.160,
5838.47363,32.598,6917.04541,-2.160,
5838.56543,32.598,6917.13721,-2.160,
5838.65674,32.598,6917.22852,-2.160,
5838.74805,31.598,6917.32031,-2.160,
5838.83984,32.598,6917.41162,-1.160,
5838.93115,32.598,6917.50293,-1.160,
5839.02295,32.598,6917.59473,-1.160,
5839.11426,32.598,6917.68604,-1.160,
5839.20605,33.598,6917.77783,-0.160,
5839.29736,32.598,6917.86914,-0.160,
5839.38916,32.598,6917.96094,-0.160,
5839.48047,32.598,6918.05225,-0.160,
5839.57178,31.598,6918.14404,0.840,
5839.66357,31.598,6918.23535,-0.160,
5839.75488,31.598,6918.32666,-0.160,
5839.84668,32.598,6918.41846,0.840,
5839.93799,31.598,6918.50977,-0.160,
5840.02979,31.598,6918.60156,-0.160,
5840.12109,32.598,6918.69287,-0.160,
5840.21240,31.598,6918.78467,-0.160,
5840.30420,31.598,6918.87598,-1.160,
5840.39551,31.598,6918.96729,-1.160,
5840.48730,31.598,6919.05908,-1.160,
5840.57861,31.598,6919.15039,-1.160,
5840.67041,32.598,6919.24219,-1.160,
5840.76172,31.598,6919.33350,-1.160,
5840.85303,31.598,6919.42529,-1.160,
5840.94482,31.598,6919.51660,-2.160,
5841.03613,31.598,6919.60791,-1.160,
5841.12793,32.598,6919.69971,-2.160,
5841.21924,31.598,6919.79102,-1.160,
5841.31104,31.598,6919.88281,-1.160,
5841.40234,31.598,6919.97412,-2.160,
5841.49414,31.598,6920.06592,-2.160,
5841.58545,31.598,6920.15723,-2.160,
5841.67676,31.598,6920.24902,-2.160,
5841.76855,31.598,6920.34033,-2.160,
5841.85986,31.598,6920.43164,-2.160,
5841.95166,31.598,6920.52344,-2.160,
5842.04297,31.598,6920.61475,-2.160,
5842.13477,31.598,6920.70654,-2.160,
5842.22607,31.598,6920.79785,-2.160,
5842.31738,32.598,6920.88965,-3.160,
5842.40918,32.598,6920.98096,-3.160,
5842.50049,31.598,6921.07227,-2.160,
5842.59229,31.598,6921.16406,-2.160,
5842.68359,31.598,6921.25537,-2.160,
5842.77539,31.598,6921.34717,-2.160,
5842.86670,31.598,6921.43848,-2.160,
5842.95801,31.598,6921.53027,-2.160,
5843.04980,31.598,6921.62158,-2.160,
5843.14111,31.598,6921.71289,-2.160,
5843.23291,31.598,6921.80469,-2.160,
5843.32422,31.598,6921.89600,-2.160,
5843.41602,30.598,6921.98779,-2.160,
5843.50732,31.598,6922.07910,-2.160,
5843.59863,32.598,6922.17090,-2.160,
5843.69043,31.598,6922.26221,-2.160,
5843.78174,32.598,6922.35400,-2.160,
5843.87354,32.598,6922.44531,-3.160,
5843.96484,31.598,6922.53662,-2.160,
5844.05664,32.598,6922.62842,-2.160,
5844.14795,31.598,6922.71973,-2.160,
5844.23975,31.598,6922.81152,-2.160,
5844.33105,31.598,6922.90283,-2.160,
5844.42236,31.598,6922.99463,-2.160,
5844.51416,31.598,6923.08594,-3.160,
5844.60547,31.598,6923.17725,-2.160,
5844.69727,31.598,6923.26904,-3.160,
5844.78857,31.598,6923.36035,-2.160,
5844.88037,30.598,6923.45215,-2.160,
5844.97168,31.598,6923.54346,-2.160,
5845.06299,32.598,6923.63525,-2.160,
5845.15479,31.598,6923.72656,-2.160,
5845.24609,31.598,6923.81787,-2.160,
5845.33789,31.598,6923.90967,-2.160,
5845.42920,31.598,6924.00098,-2.160,
5845.52100,31.598,6924.09277,-2.160,
5845.61230,31.598,6924.18408,-2.160,
5845.70361,31.598,6924.27588,-1.160,
5845.79541,30.598,6924.36719,-2.160,
5845.88672,30.598,6924.45898,-2.160,
5845.97852,31.598,6924.55029,-2.160,
5846.06982,31.598,6924.64160,-2.160,
5846.16162,31.598,6924.73340,-2.160,
5846.25293,31.598,6924.82471,-2.160,
5846.34473,31.598,6924.91650,-2.160,
5846.43604,31.598,6925.00781,-2.160,
5846.52734,32.598,6925.09961,-2.160,
5846.61914,31.598,6925.19092,-2.160,
5846.71045,31.598,6925.28223,-2.160,
5846.80225,30.598,6925.37402,-2.160,
5846.89355,31.598,6925.46533,-2.160,
5846.98535,31.598,6925.55713,-2.160,
5847.07666,31.598,6925.64844,-2.160,
5847.16797,31.598,6925.74023,-2.160,
5847.25977,31.598,6925.83154,-2.160,
5847.35107,30.598,6925.92285,-2.160,
5847.44287,31.598,6926.01465,-2.160,
5847.53418,31.598,6926.10596,-2.160,
5847.62598,30.598,6926.19775,-2.160,
5847.71729,31.598,6926.28906,-2.160,
5847.80859,30.598,6926.38086,-2.160,
5847.90039,31.598,6926.47217,-2.160,
5847.99170,31.598,6926.56396,-2.160,
5848.08350,31.598,6926.65527,-2.160,
5848.17480,31.598,6926.74658,-2.160,
5848.26660,30.598,6926.83838,-2.160,
5848.35791,31.598,6926.92969,-2.160,
5848.44971,31.598,6927.02148,-2.160,
5848.54102,31.598,6927.11279,-2.160,
5848.63232,30.598,6927.20459,-1.160,
5848.72412,31.598,6927.29590,-2.160,
5848.81543,31.598,6927.38721,-2.160,
5848.90723,30.598,6927.47900,-2.160,
5848.99854,30.598,6927.57031,-2.160,
5849.09033,31.598,6927.66211,-2.160,
5849.18164,31.598,6927.75342,-2.160,
5849.27295,30.598,6927.84521,-2.160,
5849.36475,30.598,6927.93652,-2.160,
5849.45605,31.598,6928.02783,-2.160,
5849.54785,30.598,6928.11963,-2.160,
5849.63916,31.598,6928.21094,-2.160,
5849.73096,30.598,6928.30273,-2.160,
5849.82227,30.598,6928.39404,-2.160,
5849.91357,30.598,6928.48584,-2.160,
5850.00537,30.598,6928.57715,-2.160,
5850.09668,30.598,6928.66846,-2.160,
5850.18848,30.598,6928.76025,-2.160,
5850.27979,31.598,6928.85156,-2.160,
5850.37158,31.598,6928.94336,-2.160,
5850.46289,30.598,6929.03467,-2.160,
5850.55469,31.598,6929.12646,-2.160,
5850.64600,30.598,6929.21777,-2.160,
5850.73730,30.598,6929.30957,-1.160,
5850.82910,30.598,6929.40088,-2.160,
5850.92041,31.598,6929.49219,-2.160,
5851.01221,30.598,6929.58398,-2.160,
5851.10352,30.598,6929.67529,-2.160,
5851.19531,31.598,6929.76709,-1.160,
5851.28662,30.598,6929.85840,-2.160,
5851.37793,30.598,6929.95020,-2.160,
5851.46973,30.598,6930.04150,-2.160,
5851.56104,30.598,6930.13281,-1.160,
5851.65283,30.598,6930.22461,-2.160,
5851.74414,30.598,6930.31592,-2.160,
5851.83594,30.598,6930.40771,-2.160,
5851.92725,30.598,6930.49902,-2.160,
5852.01855,30.598,6930.59082,-2.160,
5852.11035,30.598,6930.68213,-2.160,
5852.20166,31.598,6930.77344,-2.160,
5852.29346,31.598,6930.86523,-2.160,
5852.38477,32.598,6930.95654,-2.160,
5852.47656,32.598,6931.04834,-2.160,
5852.56787,32.598,6931.13965,-2.160,
5852.65967,32.598,6931.23145,-2.160,
5852.75098,32.598,6931.32275,-3.160,
5852.84229,32.598,6931.41455,-3.160,
5852.93408,31.598,6931.50586,-2.160,
5853.02539,32.598,6931.59717,-1.160,
5853.11719,31.598,6931.68896,-2.160,
5853.20850,30.598,6931.78027,-2.160,
5853.30029,30.598,6931.87207,-1.160,
5853.39160,30.598,6931.96338,-2.160,
5853.48291,30.598,6932.05518,-2.160,
5853.57471,30.598,6932.14648,-2.160,
5853.66602,30.598,6932.23779,-2.160,
5853.75781,30.598,6932.32959,-2.160,
5853.84912,30.598,6932.42090,-2.160,
5853.94092,30.598,6932.51270,-2.160,
5854.03223,30.598,6932.60400,-2.160,
5854.12354,30.598,6932.69580,-2.160,
5854.21533,30.598,6932.78711,-2.160,
5854.30664,30.598,6932.87842,-2.160,
5854.39844,29.598,6932.97021,-2.160,
5854.48975,30.598,6933.06152,-1.160,
5854.58154,30.598,6933.15332,-2.160,
5854.67285,29.598,6933.24463,-2.160,
5854.76416,29.598,6933.33643,-2.160,
5854.85596,29.598,6933.42773,-2.160,
5854.94727,30.598,6933.51953,-3.160,
5855.03906,30.598,6933.61084,-3.160,
5855.13037,30.598,6933.70215,-3.160,
5855.22217,30.598,6933.79395,-4.160,
5855.31348,30.598,6933.88525,-4.160,
5855.40527,30.598,6933.97705,-3.160,
5855.49658,30.598,6934.06836,-4.160,
5855.58789,30.598,6934.16016,-3.160,
5855.67969,30.598,6934.25146,-3.160,
5855.77100,30.598,6934.34277,-3.160,
5855.86279,30.598,6934.43457,-3.160,
5855.95410,30.598,6934.52588,-2.160,
5856.04590,30.598,6934.61768,-2.160,
5856.13721,30.598,6934.70898,-2.160,
5856.22852,29.598,6934.80078,-2.160,
5856.32031,29.598,6934.89209,-2.160,
5856.41162,30.598,6934.98340,-2.160,
5856.50342,30.598,6935.07520,-2.160,
5856.59473,29.598,6935.16650,-2.160,
5856.68652,29.598,6935.25830,-2.160,
5856.77783,30.598,6935.34961,-2.160,
5856.86914,29.598,6935.44141,-2.160,
5856.96094,29.598,6935.53271,-2.160,
5857.05225,30.598,6935.62451,-2.160,
5857.14404,29.598,6935.71582,-2.160,
5857.23535,30.598,6935.80713,-3.160,
5857.32715,30.598,6935.89893,-3.160,
5857.41846,30.598,6935.99023,-2.160,
5857.51025,30.598,6936.08203,-4.160,
5857.60156,30.598,6936.17334,-4.160,
5857.69287,29.598,6936.26514,-4.160,
5857.78467,29.598,6936.35645,-4.160,
5857.87598,29.598,6936.44775,-4.160,
5857.96777,30.598,6936.53955,-3.160,
5858.05908,29.598,6936.63086,-4.160,
5858.15088,29.598,6936.72266,-4.160,
5858.24219,30.598,6936.81396,-4.160,
5858.33350,30.598,6936.90576,-4.160,
5858.42529,29.598,6936.99707,-4.160,
5858.51660,30.598,6937.08838,-4.160,
5858.60840,30.598,6937.18018,-4.160,
5858.69971,29.598,6937.27148,-3.160,
5858.79150,29.598,6937.36328,-3.160,
5858.88281,30.598,6937.45459,-3.160,
5858.97412,30.598,6937.54639,-3.160,
5859.06592,29.598,6937.63770,-2.160,
5859.15723,29.598,6937.72949,-2.160,
5859.24902,29.598,6937.82080,-2.160,
5859.34033,29.598,6937.91211,-2.160,
5859.43213,29.598,6938.00391,-2.160,
5859.52344,29.598,6938.09521,-2.160,
5859.61523,29.598,6938.18701,-2.160,
5859.70654,30.598,6938.27832,-2.160,
5859.79785,29.598,6938.37012,-2.160,
5859.88965,30.598,6938.46143,-2.160,
5859.98096,29.598,6938.55273,-1.160,
5860.07275,29.598,6938.64453,-1.160,
5860.16406,30.598,6938.73584,-2.160,
5860.25586,29.598,6938.82764,-2.160,
5860.34717,29.598,6938.91895,-1.160,
5860.43848,29.598,6939.01074,-1.160,
5860.53027,29.598,6939.10205,-2.160,
5860.62158,29.598,6939.19336,-1.160,
5860.71338,29.598,6939.28516,-2.160,
5860.80469,29.598,6939.37646,-2.160,
5860.89648,29.598,6939.46826,-2.160,
5860.98779,29.598,6939.55957,-2.160,
5861.07910,29.598,6939.65137,-2.160,
5861.17090,29.598,6939.74268,-2.160,
5861.26221,29.598,6939.83398,-2.160,
5861.35400,29.598,6939.92578,-2.160,
5861.44531,29.598,6940.01709,-2.160,
5861.53711,29.598,6940.10889,-2.160,
5861.62842,29.598,6940.20020,-2.160,
5861.72021,29.598,6940.29199,-2.160,
5861.81152,29.598,6940.38330,-2.160,
5861.90283,29.598,6940.47510,-2.160,
5861.99463,29.598,6940.56641,-2.160,
5862.08594,29.598,6940.65771,-2.160,
5862.17773,29.598,6940.74951,-2.160,
5862.26904,29.598,6940.84082,-2.160,
5862.36084,29.598,6940.93262,-2.160,
5862.45215,28.598,6941.02393,-2.160,
5862.54346,29.598,6941.11572,-2.160,
5862.63525,29.598,6941.20703,-2.160,
5862.72656,28.598,6941.29834,-2.160,
5862.81836,29.598,6941.39014,-2.160,
5862.90967,29.598,6941.48145,-2.160,
5863.00146,29.598,6941.57324,-2.160,
5863.09277,29.598,6941.66455,-2.160,
5863.18408,29.598,6941.75635,-2.160,
5863.27588,28.598,6941.84766,-1.160,
5863.36719,29.598,6941.93896,-2.160,
5863.45898,29.598,6942.03076,-1.160,
5863.55029,29.598,6942.12207,-2.160,
5863.64209,28.598,6942.21387,-2.160,
5863.73340,29.598,6942.30518,-2.160,
5863.82520,28.598,6942.39697,-2.160,
5863.91650,28.598,6942.48828,-2.160,
5864.00781,29.598,6942.58008,-2.160,
5864.09961,29.598,6942.67139,-2.160,
5864.19092,29.598,6942.76270,-2.160,
5864.28271,28.598,6942.85449,-2.160,
5864.37402,29.598,6942.94580,-2.160,
5864.46582,28.598,6943.03760,-2.160,
5864.55713,29.598,6943.12891,-2.160,
5864.64844,29.598,6943.22070,-2.160,
5864.74023,29.598,6943.31201,-1.160,
5864.83154,28.598,6943.40332,-2.160,
5864.92334,29.598,6943.49512,-1.160,
5865.01465,29.598,6943.58643,-2.160,
5865.10645,29.598,6943.67822,-2.160,
5865.19775,28.598,6943.76953,-2.160,
5865.28906,29.598,6943.86133,-2.160,
5865.38086,29.598,6943.95264,-2.160,
5865.47217,28.598,6944.04395,-2.160,
5865.56396,30.598,6944.13574,-2.160,
5865.65527,29.598,6944.22705,-2.160,
5865.74707,28.598,6944.31885,-3.160,
5865.83838,28.598,6944.41016,-2.160,
5865.93018,29.598,6944.50195,-2.160,
5866.02148,29.598,6944.59326,-2.160,
5866.11279,29.598,6944.68506,-2.160,
5866.20459,28.598,6944.77637,-1.160,
5866.29590,29.598,6944.86768,-2.160,
5866.38770,28.598,6944.95947,-2.160,
5866.47900,29.598,6945.05078,-1.160,
5866.57080,28.598,6945.14258,-1.160,
5866.66211,28.598,6945.23389,-2.160,
5866.75342,28.598,6945.32568,-2.160,
5866.84521,28.598,6945.41699,-2.160,
5866.93652,28.598,6945.50830,-2.160,
5867.02832,29.598,6945.60010,-2.160,
5867.11963,28.598,6945.69141,-2.160,
5867.21143,28.598,6945.78320,-2.160,
5867.30273,28.598,6945.87451,-2.160,
5867.39404,28.598,6945.96631,-1.160,
5867.48584,28.598,6946.05762,-2.160,
5867.57715,28.598,6946.14893,-2.160,
5867.66895,28.598,6946.24072,-1.160,
5867.76025,29.598,6946.33203,-2.160,
5867.85205,28.598,6946.42383,-2.160,
5867.94336,28.598,6946.51514,-2.160,
5868.03467,28.598,6946.60693,-2.160,
5868.12646,28.598,6946.69824,-1.160,
5868.21777,28.598,6946.79004,-2.160,
5868.30957,28.598,6946.88135,-1.160,
5868.40088,28.598,6946.97266,-1.160,
5868.49268,28.598,6947.06445,-2.160,
5868.58398,28.598,6947.15576,-2.160,
5868.67578,28.598,6947.24756,-1.160,
5868.76709,28.598,6947.33887,-1.160,
5868.85840,28.598,6947.43066,-2.160,
5868.95020,28.598,6947.52197,-1.160,
5869.04150,28.598,6947.61328,-1.160,
5869.13330,28.598,6947.70508,-0.160,
5869.22461,28.598,6947.79639,-1.160,
5869.31641,28.598,6947.88818,-1.160,
5869.40771,28.598,6947.97949,-1.160,
5869.49902,28.598,6948.07129,-1.160,
5869.59082,28.598,6948.16260,-1.160,
5869.68213,28.598,6948.25391,-1.160,
5869.77393,27.598,6948.34570,-1.160,
5869.86523,28.598,6948.43701,-2.160,
5869.95703,28.598,6948.52881,-2.160,
5870.04834,27.598,6948.62012,-1.160,
5870.13965,27.598,6948.71191,-1.160,
5870.23145,28.598,6948.80322,-2.160,
5870.32275,27.598,6948.89502,-2.160,
5870.41455,28.598,6948.98633,-2.160,
5870.50586,28.598,6949.07764,-1.160,
5870.59766,28.598,6949.16943,-2.160,
5870.68896,27.598,6949.26074,-2.160,
5870.78076,27.598,6949.35254,-1.160,
5870.87207,27.598,6949.44385,-2.160,
5870.96338,28.598,6949.53564,-1.160,
5871.05518,27.598,6949.62695,-1.160,
5871.14648,28.598,6949.71826,-1.160,
5871.23828,28.598,6949.81006,-2.160,
5871.32959,28.598,6949.90137,-1.160,
5871.42139,29.598,6949.99316,-1.160,
5871.51270,29.598,6950.08447,-1.160,
5871.60400,28.598,6950.17627,-2.160,
5871.69580,28.598,6950.26758,-1.160,
5871.78711,28.598,6950.35889,-2.160,
5871.87891,27.598,6950.45068,-2.160,
5871.97021,28.598,6950.54199,-1.160,
5872.06201,28.598,6950.63379,-1.160,
5872.15332,27.598,6950.72510,-1.160,
5872.24463,27.598,6950.81689,-1.160,
5872.33643,27.598,6950.90820,-1.160,
5872.42773,27.598,6951.00000,-1.160,
5872.51953,27.598,6951.09131,-1.160,
5872.61084,27.598,6951.18262,-1.160,
5872.70264,28.598,6951.27441,-1.160,
5872.79395,28.598,6951.36572,-1.160,
5872.88574,29.598,6951.45752,-1.160,
5872.97705,28.598,6951.54883,-1.160,
5873.06836,28.598,6951.64063,-1.160,
5873.16016,28.598,6951.73193,-1.160,
5873.25146,28.598,6951.82324,-0.160,
5873.34326,28.598,6951.91504,-0.160,
5873.43457,28.598,6952.00635,0.840,
5873.52637,28.598,6952.09814,1.840,
5873.61768,27.598,6952.18945,0.840,
5873.70898,27.598,6952.28125,0.840,
5873.80078,27.598,6952.37256,1.840,
5873.89209,27.598,6952.46387,1.840,
5873.98389,27.598,6952.55566,1.840,
5874.07520,27.598,6952.64697,0.840,
5874.16699,27.598,6952.73877,0.840,
5874.25830,27.598,6952.83008,-0.160,
5874.34961,28.598,6952.92188,-0.160,
5874.44141,27.598,6953.01318,-0.160,
5874.53271,27.598,6953.10449,-0.160,
5874.62451,27.598,6953.19629,-1.160,
5874.71582,27.598,6953.28760,-1.160,
5874.80762,27.598,6953.37939,-1.160,
5874.89893,27.598,6953.47070,-1.160,
5874.99072,27.598,6953.56250,-1.160,
5875.08203,27.598,6953.65381,-1.160,
5875.17334,27.598,6953.74561,-1.160,
5875.26514,27.598,6953.83691,-1.160,
5875.35645,27.598,6953.92822,-1.160,
5875.44824,27.598,6954.02002,-1.160,
5875.53955,27.598,6954.11133,-1.160,
5875.63135,27.598,6954.20313,-0.160,
5875.72266,27.598,6954.29443,-0.160,
5875.81396,27.598,6954.38623,-1.160,
5875.90576,27.598,6954.47754,-0.160,
5875.99707,27.598,6954.56885,-1.160,
5876.08887,27.598,6954.66064,-1.160,
5876.18018,27.598,6954.75195,-1.160,
5876.27197,27.598,6954.84375,-1.160,
5876.36328,27.598,6954.93506,-1.160,
5876.45459,27.598,6955.02686,-1.160,
5876.54639,27.598,6955.11816,-1.160,
5876.63770,27.598,6955.20947,-1.160,
5876.72949,27.598,6955.30127,-1.160,
5876.82080,27.598,6955.39258,-1.160,
5876.91260,26.598,6955.48438,-0.160,
5877.00391,26.598,6955.57568,-1.160,
5877.09570,26.598,6955.66748,-1.160,
5877.18701,26.598,6955.75879,-1.160,
5877.27832,28.598,6955.85059,-1.160,
5877.37012,27.598,6955.94189,-1.160,
5877.46143,27.598,6956.03320,-1.160,
5877.55322,27.598,6956.12500,-1.160,
5877.64453,27.598,6956.21631,-1.160,
5877.73633,27.598,6956.30811,-0.160,
5877.82764,27.598,6956.39941,-1.160,
5877.91895,26.598,6956.49121,-1.160,
5878.01074,27.598,6956.58252,-1.160,
5878.10205,27.598,6956.67383,-1.160,
5878.19385,27.598,6956.76563,-0.160,
5878.28516,27.598,6956.85693,-1.160,
5878.37695,27.598,6956.94873,-1.160,
5878.46826,27.598,6957.04004,-1.160,
5878.55957,26.598,6957.13184,-1.160,
5878.65137,26.598,6957.22314,-1.160,
5878.74268,26.598,6957.31445,-0.160,
5878.83447,27.598,6957.40625,-2.160,
5878.92578,26.598,6957.49756,-1.160,
5879.01758,26.598,6957.58936,-1.160,
5879.10889,27.598,6957.68066,-1.160,
5879.20068,27.598,6957.77246,-1.160,
5879.29199,26.598,6957.86377,-1.160,
5879.38330,27.598,6957.95557,-0.160,
5879.47510,27.598,6958.04688,-1.160,
5879.56641,26.598,6958.13818,-1.160,
5879.65820,26.598,6958.22998,-0.160,
5879.74951,26.598,6958.32129,-1.160,
5879.84131,26.598,6958.41309,-1.160,
5879.93262,26.598,6958.50439,-1.160,
5880.02393,27.598,6958.59619,-1.160,
5880.11572,26.598,6958.68750,-1.160,
5880.20703,27.598,6958.77881,-0.160,
5880.29883,26.598,6958.87061,-1.160,
5880.39014,27.598,6958.96191,-1.160,
5880.48193,26.598,6959.05371,-1.160,
5880.57324,26.598,6959.14502,-1.160,
5880.66455,27.598,6959.23682,-1.160,
5880.75635,26.598,6959.32813,-1.160,
5880.84766,26.598,6959.41943,-0.160,
5880.93945,26.598,6959.51123,-1.160,
5881.03076,26.598,6959.60254,-1.160,
5881.12256,26.598,6959.69434,-1.160,
5881.21387,26.598,6959.78564,-0.160,
5881.30518,27.598,6959.87744,-1.160,
5881.39697,26.598,6959.96875,-1.160,
5881.48828,27.598,6960.06055,-1.160,
5881.58008,26.598,6960.15186,-1.160,
5881.67139,27.598,6960.24316,-1.160,
5881.76318,26.598,6960.33496,-1.160,
5881.85449,26.598,6960.42627,-1.160,
5881.94629,27.598,6960.51807,-1.160,
5882.03760,26.598,6960.60938,-1.160,
5882.12891,26.598,6960.70117,-1.160,
5882.22070,27.598,6960.79248,-1.160,
5882.31201,26.598,6960.88379,-0.160,
5882.40381,26.598,6960.97559,-1.160,
5882.49512,26.598,6961.06689,-1.160,
5882.58691,26.598,6961.15869,-1.160,
5882.67822,26.598,6961.25000,-0.160,
5882.76953,26.598,6961.34180,-1.160,
5882.86133,26.598,6961.43311,-1.160,
5882.95264,26.598,6961.52441,-1.160,
5883.04443,26.598,6961.61621,-1.160,
5883.13574,27.598,6961.70752,-1.160,
5883.22754,26.598,6961.79932,-1.160,
5883.31885,26.598,6961.89063,-0.160,
5883.41016,26.598,6961.98242,-1.160,
5883.50195,26.598,6962.07373,-1.160,
5883.59326,27.598,6962.16553,-1.160,
5883.68506,26.598,6962.25684,-1.160,
5883.77637,27.598,6962.34814,-0.160,
5883.86816,26.598,6962.43994,-1.160,
5883.95947,26.598,6962.53125,-1.160,
5884.05127,26.598,6962.62305,-0.160,
5884.14258,26.598,6962.71436,-1.160,
5884.23389,26.598,6962.80615,-0.160,
5884.32568,26.598,6962.89746,-1.160,
5884.41699,26.598,6962.98877,-1.160,
5884.50879,26.598,6963.08057,-0.160,
5884.60010,27.598,6963.17188,-0.160,
5884.69189,26.598,6963.26367,-0.160,
5884.78320,26.598,6963.35498,-1.160,
5884.87451,26.598,6963.44678,-0.160,
5884.96631,26.598,6963.53809,-1.160,
5885.05762,26.598,6963.62939,-1.160,
5885.14941,26.598,6963.72119,-0.160,
5885.24072,27.598,6963.81250,-0.160,
5885.33252,26.598,6963.90430,-1.160,
5885.42383,26.598,6963.99561,-1.160,
5885.51514,26.598,6964.08740,-1.160,
5885.60693,26.598,6964.17871,-1.160,
5885.69824,25.598,6964.27051,-1.160,
5885.79004,26.598,6964.36182,-1.160,
5885.88135,25.598,6964.45313,-1.160,
5885.97314,25.598,6964.54492,-1.160,
5886.06445,26.598,6964.63623,-1.160,
5886.15625,26.598,6964.72803,-1.160,
5886.24756,26.598,6964.81934,-1.160,
5886.33887,26.598,6964.91113,-1.160,
5886.43066,26.598,6965.00244,-1.160,
5886.52197,25.598,6965.09375,-1.160,
5886.61377,26.598,6965.18555,-1.160,
5886.70508,25.598,6965.27686,-0.160,
5886.79688,26.598,6965.36865,-1.160,
5886.88818,26.598,6965.45996,-1.160,
5886.97949,25.598,6965.55176,-1.160,
5887.07129,26.598,6965.64307,-1.160,
5887.16260,25.598,6965.73438,-1.160,
5887.25439,26.598,6965.82617,-1.160,
5887.34570,25.598,6965.91748,-0.160,
5887.43750,25.598,6966.00928,-1.160,
5887.52881,25.598,6966.10059,-1.160,
5887.62012,25.598,6966.19238,-1.160,
5887.71191,25.598,6966.28369,-1.160,
5887.80322,24.598,6966.37500,-1.160,
5887.89502,24.598,6966.46680,-1.160,
5887.98633,25.598,6966.55811,-1.160,
5888.07813,24.598,6966.64990,-1.160,
5888.16943,24.598,6966.74121,-0.160,
5888.26123,24.598,6966.83301,-1.160,
5888.35254,24.598,6966.92432,-1.160,
5888.44385,25.598,6967.01611,-1.160,
5888.53564,25.598,6967.10742,-1.160,
5888.62695,25.598,6967.19873,-1.160,
5888.71875,25.598,6967.29053,-1.160,
5888.81006,25.598,6967.38184,-0.160,
5888.90186,25.598,6967.47363,-1.160,
5888.99316,26.598,6967.56494,-1.160,
5889.08447,25.598,6967.65674,-1.160,
5889.17627,26.598,6967.74805,-0.160,
5889.26758,25.598,6967.83936,-0.160,
5889.35938,25.598,6967.93115,-0.160,
5889.45068,26.598,6968.02246,-1.160,
5889.54248,25.598,6968.11426,-0.160,
5889.63379,26.598,6968.20557,-0.160,
5889.72510,25.598,6968.29736,-1.160,
5889.81689,26.598,6968.38867,-1.160,
5889.90820,26.598,6968.47998,-1.160,
5890.00000,25.598,6968.57178,-1.160,
5890.09131,25.598,6968.66309,-0.160,
5890.18311,25.598,6968.75488,-0.160,
5890.27441,25.598,6968.84619,-0.160,
5890.36621,24.598,6968.93799,-0.160,
5890.45752,25.598,6969.02930,-0.160,
5890.54883,24.598,6969.12109,-1.160,
5890.64063,24.598,6969.21240,-1.160,
5890.73193,25.598,6969.30371,-1.160,
5890.82373,24.598,6969.39551,-1.160,
5890.91504,25.598,6969.48682,-0.160,
5891.00684,25.598,6969.57861,-0.160,
5891.09814,25.598,6969.66992,-0.160,
5891.18945,25.598,6969.76172,-0.160,
5891.28125,25.598,6969.85303,-1.160,
5891.37256,25.598,6969.94434,-1.160,
5891.46436,25.598,6970.03613,-1.160,
5891.55566,25.598,6970.12744,-2.160,
5891.64746,25.598,6970.21924,-2.160,
5891.73877,25.598,6970.31055,-2.160,
5891.83008,24.598,6970.40234,-1.160,
5891.92188,26.598,6970.49365,-2.160,
5892.01318,25.598,6970.58496,-2.160,
5892.10498,25.598,6970.67676,-1.160,
5892.19629,25.598,6970.76807,-1.160,
5892.28809,26.598,6970.85986,-1.160,
5892.37939,25.598,6970.95117,-1.160,
5892.47070,26.598,6971.04297,-0.160,
5892.56250,25.598,6971.13428,0.840,
5892.65381,25.598,6971.22607,-0.160,
5892.74561,25.598,6971.31738,-0.160,
5892.83691,25.598,6971.40869,-0.160,
5892.92871,25.598,6971.50049,-0.160,
5893.02002,25.598,6971.59180,-0.160,
5893.11182,25.598,6971.68359,0.840,
5893.20313,25.598,6971.77490,-0.160,
5893.29443,25.598,6971.86670,-0.160,
5893.38623,26.598,6971.95801,-0.160,
5893.47754,25.598,6972.04932,-0.160,
5893.56934,25.598,6972.14111,-1.160,
5893.66064,25.598,6972.23242,-1.160,
5893.75244,25.598,6972.32422,-0.160,
5893.84375,26.598,6972.41553,-0.160,
5893.93506,25.598,6972.50732,-0.160,
5894.02686,25.598,6972.59863,-0.160,
5894.11816,25.598,6972.68994,-0.160,
5894.20996,25.598,6972.78174,-0.160,
5894.30127,25.598,6972.87305,-1.160,
5894.39307,25.598,6972.96484,-0.160,
5894.48438,26.598,6973.05615,-1.160,
5894.57568,25.598,6973.14795,-1.160,
5894.66748,25.598,6973.23926,-1.160,
5894.75879,25.598,6973.33105,-2.160,
5894.85059,25.598,6973.42236,-1.160,
5894.94189,25.598,6973.51367,-1.160,
5895.03369,25.598,6973.60547,-2.160,
5895.12500,25.598,6973.69678,-1.160,
5895.21680,25.598,6973.78857,-2.160,
5895.30811,25.598,6973.87988,-1.160,
5895.39941,25.598,6973.97168,-1.160,
5895.49121,25.598,6974.06299,-1.160,
5895.58252,25.598,6974.15430,-1.160,
5895.67432,25.598,6974.24609,-1.160,
5895.76563,25.598,6974.33740,-1.160,
5895.85742,24.598,6974.42920,-1.160,
5895.94873,25.598,6974.52051,-0.160,
5896.04004,25.598,6974.61230,-1.160,
5896.13184,24.598,6974.70361,-0.160,
5896.22314,24.598,6974.79492,-0.160,
5896.31494,25.598,6974.88672,-1.160,
5896.40625,24.598,6974.97803,-1.160,
5896.49805,25.598,6975.06982,-0.160,
5896.58936,25.598,6975.16113,-0.160,
5896.68066,25.598,6975.25293,-1.160,
5896.77246,24.598,6975.34424,-1.160,
5896.86377,25.598,6975.43604,-0.160,
5896.95557,25.598,6975.52734,-1.160,
5897.04688,25.598,6975.61865,-1.160,
5897.13867,25.598,6975.71045,-1.160,
5897.22998,25.598,6975.80176,-1.160,
5897.32178,25.598,6975.89355,-1.160,
5897.41309,24.598,6975.98486,-0.160,
5897.50439,24.598,6976.07666,-1.160,
5897.59619,24.598,6976.16797,-0.160,
5897.68750,25.598,6976.25928,-0.160,
5897.77930,26.598,6976.35107,-1.160,
5897.87061,24.598,6976.44238,-0.160,
5897.96240,24.598,6976.53418,-1.160,
5898.05371,25.598,6976.62549,-0.160,
5898.14502,25.598,6976.71729,-0.160,
5898.23682,24.598,6976.80859,-0.160,
5898.32813,24.598,6976.89990,-0.160,
5898.41992,25.598,6976.99170,-0.160,
5898.51123,24.598,6977.08301,-0.160,
5898.60303,24.598,6977.17480,-0.160,
5898.69434,25.598,6977.26611,-0.160,
5898.78564,24.598,6977.35791,-0.160,
5898.87744,24.598,6977.44922,-0.160,
5898.96875,25.598,6977.54053,-0.160,
5899.06055,25.598,6977.63232,-0.160,
5899.15186,25.598,6977.72363,-0.160,
5899.24365,24.598,6977.81543,-0.160,
5899.33496,25.598,6977.90674,-0.160,
5899.42676,25.598,6977.99854,-0.160,
5899.51807,24.598,6978.08984,-0.160,
5899.60938,25.598,6978.18164,-0.160,
5899.70117,25.598,6978.27295,-1.160,
5899.79248,24.598,6978.36426,-1.160,
5899.88428,24.598,6978.45605,-0.160,
5899.97559,25.598,6978.54736,-0.160,
5900.06738,24.598,6978.63916,-1.160,
5900.15869,25.598,6978.73047,-0.160,
5900.25000,24.598,6978.82227,-0.160,
5900.34180,24.598,6978.91357,-1.160,
5900.43311,24.598,6979.00488,-0.160,
5900.52490,25.598,6979.09668,-0.160,
5900.61621,25.598,6979.18799,-0.160,
5900.70801,25.598,6979.27979,-0.160,
5900.79932,25.598,6979.37109,-0.160,
5900.89063,24.598,6979.46289,-0.160,
5900.98242,25.598,6979.55420,-1.160,
5901.07373,25.598,6979.64551,-1.160,
5901.16553,25.598,6979.73730,-0.160,
5901.25684,25.598,6979.82861,-0.160,
5901.34863,24.598,6979.92041,-0.160,
5901.43994,25.598,6980.01172,-0.160,
5901.53174,25.598,6980.10352,-0.160,
5901.62305,24.598,6980.19482,-1.160,
5901.71436,25.598,6980.28662,-0.160,
5901.80615,24.598,6980.37793,-0.160,
5901.89746,24.598,6980.46924,-0.160,
5901.98926,24.598,6980.56104,-0.160,
5902.08057,24.598,6980.65234,-0.160,
5902.17236,25.598,6980.74414,-0.160,
5902.26367,24.598,6980.83545,-0.160,
5902.35498,24.598,6980.92725,-0.160,
5902.44678,24.598,6981.01855,-1.160,
5902.53809,24.598,6981.10986,-1.160,
5902.62988,25.598,6981.20166,-0.160,
5902.72119,24.598,6981.29297,-1.160,
5902.81299,24.598,6981.38477,-0.160,
5902.90430,24.598,6981.47607,-0.160,
5902.99561,24.598,6981.56787,-0.160,
5903.08740,24.598,6981.65918,-0.160,
5903.17871,24.598,6981.75049,-0.160,
5903.27051,24.598,6981.84229,-0.160,
5903.36182,24.598,6981.93359,-1.160,
5903.45361,24.598,6982.02539,-0.160,
5903.54492,24.598,6982.11670,-0.160,
5903.63672,25.598,6982.20850,-0.160,
5903.72803,24.598,6982.29980,-0.160,
5903.81934,24.598,6982.39160,-0.160,
5903.91113,24.598,6982.48291,-0.160,
5904.00244,24.598,6982.57422,-0.160,
5904.09424,25.598,6982.66602,-1.160,
5904.18555,24.598,6982.75732,-0.160,
5904.27734,24.598,6982.84912,-0.160,
5904.36865,24.598,6982.94043,-0.160,
5904.45996,24.598,6983.03223,-0.160,
5904.55176,24.598,6983.12354,-0.160,
5904.64307,24.598,6983.21484,-0.160,
5904.73486,23.598,6983.30664,-0.160,
5904.82617,24.598,6983.39795,-0.160,
5904.91797,24.598,6983.48975,-0.160,
5905.00928,24.598,6983.58105,-0.160,
5905.10059,24.598,6983.67285,-1.160,
5905.19238,24.598,6983.76416,-0.160,
5905.28369,24.598,6983.85547,-1.160,
5905.37549,23.598,6983.94727,-0.160,
5905.46680,24.598,6984.03857,-0.160,
5905.55859,24.598,6984.13037,-1.160,
5905.64990,24.598,6984.22168,-1.160,
5905.74121,24.598,6984.31348,0.840,
5905.83301,24.598,6984.40479,-0.160,
5905.92432,24.598,6984.49658,-0.160,
5906.01611,24.598,6984.58789,-0.160,
5906.10742,24.598,6984.67920,-0.160,
5906.19922,24.598,6984.77100,-1.160,
5906.29053,24.598,6984.86230,-0.160,
5906.38232,24.598,6984.95410,-0.160,
5906.47363,24.598,6985.04541,-1.160,
5906.56494,24.598,6985.13721,-1.160,
5906.65674,24.598,6985.22852,-0.160,
5906.74805,24.598,6985.31982,-0.160,
5906.83984,23.598,6985.41162,-1.160,
5906.93115,23.598,6985.50293,-0.160,
5907.02295,24.598,6985.59473,-0.160,
5907.11426,24.598,6985.68604,-0.160,
5907.20557,24.598,6985.77783,-0.160,
5907.29736,23.598,6985.86914,-0.160,
5907.38867,24.598,6985.96045,-0.160,
5907.48047,23.598,6986.05225,-0.160,
5907.57178,24.598,6986.14355,-0.160,
5907.66357,24.598,6986.23535,-0.160,
5907.75488,24.598,6986.32666,-0.160,
5907.84619,24.598,6986.41846,-0.160,
5907.93799,24.598,6986.50977,-0.160,
5908.02930,24.598,6986.60156,-1.160,
5908.12109,24.598,6986.69287,-0.160,
5908.21240,24.598,6986.78418,-0.160,
5908.30420,24.598,6986.87598,-1.160,
5908.39551,24.598,6986.96729,-0.160,
5908.48730,24.598,6987.05908,-0.160,
5908.57861,25.598,6987.15039,-1.160,
5908.66992,25.598,6987.24219,-0.160,
5908.76172,25.598,6987.33350,-0.160,
5908.85303,24.598,6987.42480,-0.160,
5908.94482,25.598,6987.51660,-0.160,
5909.03613,24.598,6987.60791,-0.160,
5909.12793,24.598,6987.69971,-0.160,
5909.21924,24.598,6987.79102,-0.160,
5909.31055,23.598,6987.88281,0.840,
5909.40234,24.598,6987.97412,0.840,
5909.49365,24.598,6988.06543,-0.160,
5909.58545,24.598,6988.15723,-0.160,
5909.67676,24.598,6988.24854,0.840,
5909.76855,23.598,6988.34033,0.840,
5909.85986,24.598,6988.43164,0.840,
5909.95117,24.598,6988.52344,1.840,
5910.04297,24.598,6988.61475,1.840,
5910.13428,24.598,6988.70654,1.840,
5910.22607,24.598,6988.79785,0.840,
5910.31738,23.598,6988.88916,0.840,
5910.40918,23.598,6988.98096,0.840,
5910.50049,23.598,6989.07227,-0.160,
5910.59229,24.598,6989.16406,0.840,
5910.68359,23.598,6989.25537,-0.160,
5910.77490,23.598,6989.34717,-0.160,
5910.86670,24.598,6989.43848,-0.160,
5910.95801,24.598,6989.52979,-0.160,
5911.04980,24.598,6989.62158,-0.160,
5911.14111,24.598,6989.71289,-1.160,
5911.23291,24.598,6989.80469,-0.160,
5911.32422,24.598,6989.89600,-1.160,
5911.41553,24.598,6989.98779,-1.160,
5911.50732,24.598,6990.07910,-0.160,
5911.59863,24.598,6990.17041,0.840,
5911.69043,24.598,6990.26221,-0.160,
5911.78174,23.598,6990.35352,-0.160,
5911.87354,24.598,6990.44531,0.840,
5911.96484,24.598,6990.53662,0.840,
5912.05615,23.598,6990.62842,-0.160,
5912.14795,24.598,6990.71973,0.840,
5912.23926,24.598,6990.81104,-0.160,
5912.33105,23.598,6990.90283,-0.160,
5912.42236,24.598,6990.99414,-0.160,
5912.51416,24.598,6991.08594,-1.160,
5912.60547,23.598,6991.17725,-0.160,
5912.69727,23.598,6991.26904,-0.160,
5912.78857,24.598,6991.36035,-0.160,
5912.87988,24.598,6991.45215,-1.160,
5912.97168,23.598,6991.54346,-1.160,
5913.06299,24.598,6991.63477,-1.160,
5913.15479,23.598,6991.72656,-1.160,
5913.24609,24.598,6991.81787,-0.160,
5913.33789,23.598,6991.90967,-1.160,
5913.42920,24.598,6992.00098,-1.160,
5913.52051,23.598,6992.09277,-1.160,
5913.61230,24.598,6992.18408,-1.160,
5913.70361,24.598,6992.27539,-0.160,
5913.79541,24.598,6992.36719,-1.160,
5913.88672,24.598,6992.45850,-1.160,
5913.97852,23.598,6992.55029,-1.160,
5914.06982,24.598,6992.64160,-1.160,
5914.16113,23.598,6992.73340,-0.160,
5914.25293,24.598,6992.82471,-0.160,
5914.34424,23.598,6992.91602,-0.160,
5914.43604,24.598,6993.00781,-1.160,
5914.52734,23.598,6993.09912,-0.160,
5914.61914,23.598,6993.19092,-0.160,
5914.71045,24.598,6993.28223,-0.160,
5914.80225,23.598,6993.37402,-0.160,
5914.89355,23.598,6993.46533,-0.160,
5914.98486,23.598,6993.55713,-0.160,
5915.07666,23.598,6993.64844,-0.160,
5915.16797,23.598,6993.73975,-1.160,
5915.25977,23.598,6993.83154,-1.160,
5915.35107,24.598,6993.92285,-1.160,
5915.44287,23.598,6994.01465,-1.160,
5915.53418,24.598,6994.10596,-1.160,
5915.62549,24.598,6994.19775,-1.160,
5915.71729,23.598,6994.28906,-1.160,
5915.80859,23.598,6994.38037,-1.160,
5915.90039,23.598,6994.47217,-1.160,
5915.99170,23.598,6994.56348,-0.160,
5916.08350,23.598,6994.65527,-1.160,
5916.17480,23.598,6994.74658,-1.160,
5916.26611,23.598,6994.83838,-0.160,
5916.35791,23.598,6994.92969,-1.160,
5916.44922,23.598,6995.02100,-1.160,
5916.54102,23.598,6995.11279,-1.160,
5916.63232,23.598,6995.20410,-1.160,
5916.72412,23.598,6995.29590,-1.160,
5916.81543,23.598,6995.38721,-1.160,
5916.90674,23.598,6995.47900,-1.160,
5916.99854,24.598,6995.57031,-0.160,
5917.08984,23.598,6995.66211,-0.160,
5917.18164,24.598,6995.75342,-1.160,
5917.27295,23.598,6995.84473,-1.160,
5917.36475,24.598,6995.93652,-1.160,
5917.45605,24.598,6996.02783,-1.160,
5917.54785,23.598,6996.11963,-1.160,
5917.63916,23.598,6996.21094,-1.160,
5917.73047,23.598,6996.30273,-1.160,
5917.82227,23.598,6996.39404,-1.160,
5917.91357,23.598,6996.48535,-1.160,
5918.00537,23.598,6996.57715,-1.160,
5918.09668,24.598,6996.66846,-1.160,
5918.18848,23.598,6996.76025,-1.160,
5918.27979,24.598,6996.85156,-1.160,
5918.37109,24.598,6996.94336,-1.160,
5918.46289,24.598,6997.03467,-1.160,
5918.55420,23.598,6997.12598,-1.160,
5918.64600,24.598,6997.21777,-1.160,
5918.73730,24.598,6997.30908,-1.160,
5918.82910,23.598,6997.40088,-1.160,
5918.92041,23.598,6997.49219,-0.160,
5919.01172,24.598,6997.58398,-1.160,
5919.10352,23.598,6997.67529,-1.160,
5919.19482,23.598,6997.76709,-1.160,
5919.28662,23.598,6997.85840,-1.160,
5919.37793,23.598,6997.94971,-1.160,
5919.46973,23.598,6998.04150,-1.160,
5919.56104,23.598,6998.13281,-1.160,
5919.65283,23.598,6998.22461,-1.160,
5919.74414,23.598,6998.31592,-1.160,
5919.83545,23.598,6998.40771,-1.160,
5919.92725,23.598,6998.49902,-1.160,
5920.01855,23.598,6998.59033,-1.160,
5920.11035,22.598,6998.68213,-1.160,
5920.20166,23.598,6998.77344,-1.160,
5920.29346,23.598,6998.86523,-1.160,
5920.38477,23.598,6998.95654,-0.160,
5920.47607,23.598,6999.04834,-1.160,
5920.56787,23.598,6999.13965,-1.160,
5920.65918,23.598,6999.23096,-1.160,
5920.75098,23.598,6999.32275,-1.160,
5920.84229,23.598,6999.41406,-1.160,
5920.93408,23.598,6999.50586,-1.160,
5921.02539,23.598,6999.59717,-0.160,
5921.11670,23.598,6999.68896,-1.160,
5921.20850,24.598,6999.78027,-1.160,
5921.29980,23.598,6999.87207,-1.160,
5921.39160,23.598,6999.96338,-1.160,
5921.48291,23.598,7000.05469,-1.160,
5921.57471,23.598,7000.14648,-1.160,
5921.66602,23.598,7000.23779,-1.160,
5921.75781,23.598,7000.32959,-1.160,
5921.84912,23.598,7000.42090,-1.160,
5921.94043,23.598,7000.51270,-1.160,
5922.03223,23.598,7000.60400,-1.160,
5922.12354,23.598,7000.69531,-1.160,
5922.21533,23.598,7000.78711,-1.160,
5922.30664,23.598,7000.87842,-1.160,
5922.39844,23.598,7000.97021,-2.160,
5922.48975,23.598,7001.06152,-1.160,
5922.58105,23.598,7001.15332,-1.160,
5922.67285,23.598,7001.24463,-2.160,
5922.76416,23.598,7001.33594,-2.160,
5922.85596,23.598,7001.42773,-2.160,
5922.94727,23.598,7001.51904,-1.160,
5923.03906,23.598,7001.61084,-1.160,
5923.13037,23.598,7001.70215,-1.160,
5923.22168,23.598,7001.79395,-1.160,
5923.31348,23.598,7001.88525,-1.160,
5923.40479,23.598,7001.97656,-1.160,
5923.49658,23.598,7002.06836,-1.160,
5923.58789,23.598,7002.15967,-1.160,
5923.67969,23.598,7002.25146,-1.160,
5923.77100,23.598,7002.34277,-1.160,
5923.86279,23.598,7002.43457,-0.160,
5923.95410,23.598,7002.52588,-1.160,
5924.04541,22.598,7002.61768,-0.160,
5924.13721,24.598,7002.70898,-1.160,
5924.22852,23.598,7002.80029,-1.160,
5924.32031,23.598,7002.89209,-1.160,
5924.41162,23.598,7002.98340,-1.160,
5924.50342,23.598,7003.07520,-1.160,
5924.59473,23.598,7003.16650,-1.160,
5924.68604,23.598,7003.25830,-1.160,
5924.77783,23.598,7003.34961,-0.160,
5924.86914,23.598,7003.44092,-1.160,
5924.96094,23.598,7003.53271,-1.160,
5925.05225,23.598,7003.62402,-1.160,
5925.14404,23.598,7003.71582,-1.160,
5925.23535,23.598,7003.80713,-1.160,
5925.32666,23.598,7003.89893,-1.160,
5925.41846,23.598,7003.99023,-1.160,
5925.50977,23.598,7004.08154,-1.160,
5925.60156,23.598,7004.17334,-1.160,
5925.69287,23.598,7004.26465,-1.160,
5925.78467,23.598,7004.35645,-1.160,
5925.87598,23.598,7004.44775,-1.160,
5925.96777,23.598,7004.53955,-1.160,
5926.05908,23.598,7004.63086,-1.160,
5926.15039,23.598,7004.72266,-1.160,
5926.24219,23.598,7004.81396,-0.160,
5926.33350,23.598,7004.90527,-0.160,
5926.42529,22.598,7004.99707,-1.160,
5926.51660,22.598,7005.08838,-0.160,
5926.60840,23.598,7005.18018,-1.160,
5926.69971,23.598,7005.27148,-1.160,
5926.79102,22.598,7005.36328,-1.160,
5926.88281,22.598,7005.45459,-1.160,
5926.97412,23.598,7005.54590,-1.160,
5927.06592,23.598,7005.63770,-2.160,
5927.15723,23.598,7005.72900,-2.160,
5927.24902,23.598,7005.82080,-2.160,
5927.34033,24.598,7005.91211,-2.160,
5927.43164,24.598,7006.00391,-2.160,
5927.52344,25.598,7006.09521,-2.160,
5927.61475,24.598,7006.18652,-1.160,
5927.70654,24.598,7006.27832,-1.160,
5927.79785,23.598,7006.36963,-0.160,
5927.88965,23.598,7006.46143,-0.160,
5927.98096,23.598,7006.55273,-0.160,
5928.07275,23.598,7006.64453,-0.160,
5928.16406,23.598,7006.73584,-0.160,
5928.25537,23.598,7006.82764,-0.160,
5928.34717,23.598,7006.91895,-0.160,
5928.43848,23.598,7007.01025,-0.160,
5928.53027,24.598,7007.10205,-1.160,
5928.62158,23.598,7007.19336,-1.160,
5928.71338,22.598,7007.28516,-1.160,
5928.80469,23.598,7007.37646,-1.160,
5928.89600,22.598,7007.46826,-1.160,
5928.98779,23.598,7007.55957,-1.160,
5929.07910,23.598,7007.65088,-1.160,
5929.17090,22.598,7007.74268,-0.160,
5929.26221,23.598,7007.83398,-0.160,
5929.35400,22.598,7007.92578,-0.160,
5929.44531,22.598,7008.01709,-0.160,
5929.53662,22.598,7008.10889,0.840,
5929.62842,22.598,7008.20020,0.840,
5929.71973,22.598,7008.29150,0.840,
5929.81152,22.598,7008.38330,0.840,
5929.90283,23.598,7008.47461,0.840,
5929.99463,23.598,7008.56641,0.840,
5930.08594,23.598,7008.65771,0.840,
5930.17725,23.598,7008.74951,-0.160,
5930.26904,22.598,7008.84082,-0.160,
5930.36035,23.598,7008.93262,-0.160,
5930.45215,22.598,7009.02393,-0.160,
5930.54346,23.598,7009.11523,-0.160,
5930.63525,23.598,7009.20703,-0.160,
5930.72656,23.598,7009.29834,-1.160,
5930.81836,23.598,7009.39014,-1.160,
5930.90967,22.598,7009.48145,-1.160,
5931.00098,22.598,7009.57324,-1.160,
5931.09277,22.598,7009.66455,-1.160,
5931.18408,22.598,7009.75586,-1.160,
5931.27588,22.598,7009.84766,-1.160,
5931.36719,22.598,7009.93896,-1.160,
5931.45898,23.598,7010.03076,-1.160,
5931.55029,22.598,7010.12207,-1.160,
5931.64160,22.598,7010.21387,-1.160,
5931.73340,23.598,7010.30518,-1.160,
5931.82471,22.598,7010.39648,-1.160,
5931.91650,22.598,7010.48828,-1.160,
5932.00781,23.598,7010.57959,-1.160,
5932.09961,23.598,7010.67139,-0.160,
5932.19092,22.598,7010.76270,-1.160,
5932.28223,22.598,7010.85449,-1.160,
5932.37402,22.598,7010.94580,-1.160,
5932.46533,22.598,7011.03760,-1.160,
5932.55713,22.598,7011.12891,-1.160,
5932.64844,22.598,7011.22021,-2.160,
5932.74023,23.598,7011.31201,-1.160,
5932.83154,23.598,7011.40332,-1.160,
5932.92334,23.598,7011.49512,-1.160,
5933.01465,23.598,7011.58643,-2.160,
5933.10596,23.598,7011.67822,-1.160,
5933.19775,22.598,7011.76953,-1.160,
5933.28906,22.598,7011.86084,-1.160,
5933.38086,22.598,7011.95264,-1.160,
5933.47217,23.598,7012.04395,-1.160,
5933.56396,22.598,7012.13574,-0.160,
5933.65527,23.598,7012.22705,-1.160,
5933.74658,22.598,7012.31885,-1.160,
5933.83838,22.598,7012.41016,-1.160,
5933.92969,22.598,7012.50146,-1.160,
5934.02148,22.598,7012.59326,-1.160,
5934.11279,22.598,7012.68457,-1.160,
5934.20459,22.598,7012.77637,-1.160,
5934.29590,22.598,7012.86768,-1.160,
5934.38721,23.598,7012.95947,-1.160,
5934.47900,22.598,7013.05078,-1.160,
5934.57031,22.598,7013.14258,-1.160,
5934.66211,22.598,7013.23389,-1.160,
5934.75342,22.598,7013.32520,-1.160,
5934.84521,23.598,7013.41699,-1.160,
5934.93652,23.598,7013.50830,-1.160,
5935.02832,23.598,7013.60010,-0.160,
5935.11963,22.598,7013.69141,-1.160,
5935.21094,22.598,7013.78320,-1.160,
5935.30273,22.598,7013.87451,-1.160,
5935.39404,22.598,7013.96582,-1.160,
5935.48584,22.598,7014.05762,-1.160,
5935.57715,22.598,7014.14893,-1.160,
5935.66895,22.598,7014.24072,-1.160,
5935.76025,22.598,7014.33203,-1.160,
5935.85156,23.598,7014.42383,-1.160,
5935.94336,22.598,7014.51514,-1.160,
5936.03467,22.598,7014.60645,-1.160,
5936.12646,22.598,7014.69824,-1.160,
5936.21777,22.598,7014.78955,-1.160,
5936.30957,22.598,7014.88135,-1.160,
5936.40088,22.598,7014.97266,-1.160,
5936.49219,23.598,7015.06445,-0.160,
5936.58398,22.598,7015.15576,-1.160,
5936.67529,22.598,7015.24707,-1.160,
5936.76709,22.598,7015.33887,-1.160,
5936.85840,22.598,7015.43018,-1.160,
5936.95020,22.598,7015.52197,-1.160,
5937.04150,22.598,7015.61328,-1.160,
5937.13330,22.598,7015.70508,-1.160,
5937.22461,22.598,7015.79639,-1.160,
5937.31592,22.598,7015.88818,-2.160,
5937.40771,22.598,7015.97949,-1.160,
5937.49902,23.598,7016.07080,-2.160,
5937.59082,22.598,7016.16260,-1.160,
5937.68213,23.598,7016.25391,-1.160,
5937.77393,22.598,7016.34570,-1.160,
5937.86523,22.598,7016.43701,-2.160,
5937.95654,22.598,7016.52881,-0.160,
5938.04834,22.598,7016.62012,-1.160,
5938.13965,22.598,7016.71143,-1.160,
5938.23145,22.598,7016.80322,-1.160,
5938.32275,22.598,7016.89453,-1.160,
5938.41455,22.598,7016.98633,-1.160,
5938.50586,22.598,7017.07764,-1.160,
5938.59717,22.598,7017.16943,-1.160,
5938.68896,22.598,7017.26074,-1.160,
5938.78027,22.598,7017.35205,-1.160,
5938.87207,22.598,7017.44385,-1.160,
5938.96338,21.598,7017.53516,-1.160,
5939.05518,21.598,7017.62695,-1.160,
5939.14648,22.598,7017.71826,-1.160,
5939.23828,22.598,7017.81006,-1.160,
5939.32959,22.598,7017.90137,-1.160,
5939.42090,22.598,7017.99316,-0.160,
5939.51270,22.598,7018.08447,-1.160,
5939.60400,21.598,7018.17578,-1.160,
5939.69580,21.598,7018.26758,-1.160,
5939.78711,22.598,7018.35889,-1.160,
5939.87891,21.598,7018.45068,-1.160,
5939.97021,21.598,7018.54199,-2.160,
5940.06152,21.598,7018.63379,-1.160,
5940.15332,22.598,7018.72510,-1.160,
5940.24463,22.598,7018.81641,-1.160,
5940.33643,22.598,7018.90820,-1.160,
5940.42773,21.598,7018.99951,-1.160,
5940.51953,21.598,7019.09131,-1.160,
5940.61084,21.598,7019.18262,-2.160,
5940.70215,22.598,7019.27441,-1.160,
5940.79395,22.598,7019.36572,-1.160,
5940.88525,22.598,7019.45703,-1.160,
5940.97705,22.598,7019.54883,-1.160,
5941.06836,22.598,7019.64014,-2.160,
5941.16016,22.598,7019.73193,-2.160,
5941.25146,21.598,7019.82324,-1.160,
5941.34326,22.598,7019.91504,-1.160,
5941.43457,22.598,7020.00635,-1.160,
5941.52588,21.598,7020.09814,-2.160,
5941.61768,22.598,7020.18945,-1.160,
5941.70898,23.598,7020.28076,-2.160,
5941.80078,22.598,7020.37256,-2.160,
5941.89209,21.598,7020.46387,-2.160,
5941.98389,21.598,7020.55566,-2.160,
5942.07520,22.598,7020.64697,-2.160,
5942.16650,22.598,7020.73877,-2.160,
5942.25830,22.598,7020.83008,-2.160,
5942.34961,21.598,7020.92139,-1.160,
5942.44141,21.598,7021.01318,-1.160,
5942.53271,22.598,7021.10449,-1.160,
5942.62451,22.598,7021.19629,-2.160,
5942.71582,21.598,7021.28760,-2.160,
5942.80713,21.598,7021.37939,-1.160,
5942.89893,22.598,7021.47070,-2.160,
5942.99023,21.598,7021.56201,-1.160,
5943.08203,21.598,7021.65381,-2.160,
5943.17334,22.598,7021.74512,-2.160,
5943.26514,22.598,7021.83691,-2.160,
5943.35645,22.598,7021.92822,-2.160,
5943.44775,22.598,7022.02002,-2.160,
5943.53955,22.598,7022.11133,-2.160,
5943.63086,22.598,7022.20313,-2.160,
5943.72266,22.598,7022.29443,-1.160,
5943.81396,22.598,7022.38574,-1.160,
5943.90576,22.598,7022.47754,-1.160,
5943.99707,22.598,7022.56885,-2.160,
5944.08887,22.598,7022.66064,-1.160,
5944.18018,22.598,7022.75195,-1.160,
5944.27148,22.598,7022.84375,-2.160,
5944.36328,22.598,7022.93506,-1.160,
5944.45459,22.598,7023.02637,-1.160,
5944.54639,21.598,7023.11816,-2.160,
5944.63770,22.598,7023.20947,-1.160,
5944.72949,22.598,7023.30127,-1.160,
5944.82080,22.598,7023.39258,-1.160,
5944.91211,22.598,7023.48438,-2.160,
5945.00391,22.598,7023.57568,-2.160,
5945.09521,22.598,7023.66699,-2.160,
5945.18701,21.598,7023.75879,-3.160,
5945.27832,22.598,7023.85010,-3.160,
5945.37012,21.598,7023.94189,-3.160,
5945.46143,22.598,7024.03320,-3.160,
5945.55273,22.598,7024.12500,-3.160,
5945.64453,23.598,7024.21631,-3.160,
5945.73584,23.598,7024.30811,-3.160,
5945.82764,23.598,7024.39941,-3.160,
5945.91895,23.598,7024.49072,-3.160,
5946.01074,23.598,7024.58252,-2.160,
5946.10205,23.598,7024.67383,-2.160,
5946.19385,23.598,7024.76563,-2.160,
5946.28516,23.598,7024.85693,-2.160,
5946.37646,22.598,7024.94873,-2.160,
5946.46826,22.598,7025.04004,-1.160,
5946.55957,22.598,7025.13135,-2.160,
5946.65137,22.598,7025.22314,-1.160,
5946.74268,22.598,7025.31445,-1.160,
5946.83447,22.598,7025.40625,-1.160,
5946.92578,21.598,7025.49756,-1.160,
5947.01709,21.598,7025.58936,-1.160,
5947.10889,21.598,7025.68066,-1.160,
5947.20020,21.598,7025.77197,-1.160,
5947.29199,21.598,7025.86377,-2.160,
5947.38330,21.598,7025.95508,-1.160,
5947.47510,22.598,7026.04688,-0.160,
5947.56641,22.598,7026.13818,-0.160,
5947.65771,21.598,7026.22998,-0.160,
5947.74951,21.598,7026.32129,0.840,
5947.84082,22.598,7026.41309,1.840,
5947.93262,21.598,7026.50439,0.840,
5948.02393,21.598,7026.59570,1.840,
5948.11572,21.598,7026.68750,1.840,
5948.20703,22.598,7026.77881,1.840,
5948.29883,21.598,7026.87061,0.840,
5948.39014,21.598,7026.96191,1.840,
5948.48145,21.598,7027.05371,0.840,
5948.57324,21.598,7027.14502,0.840,
5948.66455,21.598,7027.23633,0.840,
5948.75635,21.598,7027.32813,0.840,
5948.84766,21.598,7027.41943,-0.160,
5948.93945,22.598,7027.51123,-0.160,
5949.03076,22.598,7027.60254,-0.160,
5949.12207,22.598,7027.69434,-0.160,
5949.21387,21.598,7027.78564,-0.160,
5949.30518,22.598,7027.87695,-1.160,
5949.39697,22.598,7027.96875,-1.160,
5949.48828,22.598,7028.06006,-2.160,
5949.58008,22.598,7028.15186,-1.160,
5949.67139,22.598,7028.24316,-1.160,
5949.76270,21.598,7028.33496,-1.160,
5949.85449,22.598,7028.42627,-2.160,
5949.94580,22.598,7028.51758,-2.160,
5950.03760,21.598,7028.60938,-2.160,
5950.12891,21.598,7028.70068,-1.160,
5950.22070,22.598,7028.79248,-1.160,
5950.31201,21.598,7028.88379,-2.160,
5950.40381,21.598,7028.97559,-1.160,
5950.49512,22.598,7029.06689,-1.160,
5950.58643,22.598,7029.15869,-2.160,
5950.67822,21.598,7029.25000,-2.160,
5950.76953,21.598,7029.34131,-2.160,
5950.86133,22.598,7029.43311,-1.160,
5950.95264,21.598,7029.52441,-1.160,
5951.04443,21.598,7029.61621,-2.160,
5951.13574,22.598,7029.70752,-1.160,
5951.22705,22.598,7029.79932,-1.160,
5951.31885,21.598,7029.89063,-2.160,
5951.41016,21.598,7029.98193,-1.160,
5951.50195,22.598,7030.07373,-1.160,
5951.59326,21.598,7030.16504,-2.160,
5951.68506,21.598,7030.25684,-1.160,
5951.77637,21.598,7030.34814,-1.160,
5951.86768,21.598,7030.43994,-1.160,
5951.95947,22.598,7030.53125,-2.160,
5952.05078,21.598,7030.62256,-2.160,
5952.14258,22.598,7030.71436,-2.160,
5952.23389,21.598,7030.80566,-1.160,
5952.32568,21.598,7030.89746,-1.160,
5952.41699,22.598,7030.98877,-1.160,
5952.50879,22.598,7031.08057,-1.160,
5952.60010,21.598,7031.17188,-1.160,
5952.69141,21.598,7031.26367,-1.160,
5952.78320,22.598,7031.35498,-1.160,
5952.87451,22.598,7031.44629,-2.160,
5952.96631,21.598,7031.53809,-1.160,
5953.05762,22.598,7031.62939,-1.160,
5953.14941,21.598,7031.72119,-1.160,
5953.24072,22.598,7031.81250,-1.160,
5953.33203,22.598,7031.90430,-1.160,
5953.42383,21.598,7031.99561,-1.160,
5953.51514,21.598,7032.08691,-1.160,
5953.60693,21.598,7032.17871,-1.160,
5953.69824,22.598,7032.27002,-2.160,
5953.79004,21.598,7032.36182,-1.160,
5953.88135,21.598,7032.45313,-1.160,
5953.97266,21.598,7032.54492,-1.160,
5954.06445,21.598,7032.63623,-1.160,
5954.15576,21.598,7032.72754,-2.160,
5954.24756,21.598,7032.81934,-1.160,
5954.33887,21.598,7032.91064,-1.160,
5954.43066,21.598,7033.00244,-1.160,
5954.52197,21.598,7033.09375,-1.160,
5954.61328,21.598,7033.18555,-2.160,
5954.70508,21.598,7033.27686,-2.160,
5954.79639,21.598,7033.36865,-1.160,
5954.88818,22.598,7033.45996,-1.160,
5954.97949,22.598,7033.55127,-1.160,
5955.07129,21.598,7033.64307,-2.160,
5955.16260,21.598,7033.73438,-1.160,
5955.25439,21.598,7033.82617,-1.160,
5955.34570,21.598,7033.91748,-1.160,
5955.43701,21.598,7034.00928,-1.160,
5955.52881,21.598,7034.10059,-0.160,
5955.62012,21.598,7034.19189,-1.160,
5955.71191,20.598,7034.28369,-1.160,
5955.80322,21.598,7034.37500,-1.160,
5955.89502,21.598,7034.46680,-1.160,
5955.98633,21.598,7034.55811,-1.160,
5956.07764,22.598,7034.64990,-1.160,
5956.16943,21.598,7034.74121,-1.160,
5956.26074,21.598,7034.83252,-1.160,
5956.35254,22.598,7034.92432,-1.160,
5956.44385,21.598,7035.01563,-1.160,
5956.53564,21.598,7035.10742,-1.160,
5956.62695,21.598,7035.19873,-1.160,
5956.71826,21.598,7035.29053,-1.160,
5956.81006,21.598,7035.38184,-2.160,
5956.90137,21.598,7035.47363,-1.160,
5956.99316,21.598,7035.56494,-0.160,
5957.08447,21.598,7035.65625,-1.160,
5957.17627,21.598,7035.74805,-1.160,
5957.26758,21.598,7035.83936,-1.160,
5957.35938,21.598,7035.93115,-1.160,
5957.45068,21.598,7036.02246,-1.160,
5957.54199,21.598,7036.11426,-1.160,
5957.63379,21.598,7036.20557,-1.160,
5957.72510,21.598,7036.29688,-1.160,
5957.81689,21.598,7036.38867,-1.160,
5957.90820,21.598,7036.47998,-1.160,
5958.00000,21.598,7036.57178,-1.160,
5958.09131,21.598,7036.66309,-1.160,
5958.18262,21.598,7036.75488,-1.160,
5958.27441,21.598,7036.84619,-1.160,
5958.36572,21.598,7036.93750,-1.160,
5958.45752,21.598,7037.02930,-1.160,
5958.54883,21.598,7037.12061,-1.160,
5958.64063,20.598,7037.21240,-1.160,
5958.73193,21.598,7037.30371,-1.160,
5958.82324,20.598,7037.39551,-1.160,
5958.91504,20.598,7037.48682,-1.160,
5959.00635,20.598,7037.57861,-2.160,
5959.09814,21.598,7037.66992,-1.160,
5959.18945,21.598,7037.76123,-1.160,
5959.28125,21.598,7037.85303,-1.160,
5959.37256,20.598,7037.94434,-1.160,
5959.46436,21.598,7038.03613,-2.160,
5959.55566,20.598,7038.12744,-1.160,
5959.64697,20.598,7038.21924,-1.160,
5959.73877,21.598,7038.31055,-1.160,
5959.83008,21.598,7038.40186,-1.160,
5959.92188,21.598,7038.49365,-1.160,
5960.01318,21.598,7038.58496,-2.160,
5960.10498,21.598,7038.67676,-1.160,
5960.19629,20.598,7038.76807,-1.160,
5960.28760,20.598,7038.85986,-1.160,
5960.37939,21.598,7038.95117,-1.160,
5960.47070,21.598,7039.04248,-1.160,
5960.56250,20.598,7039.13428,-2.160,
5960.65381,21.598,7039.22559,-2.160,
5960.74561,21.598,7039.31738,-1.160,
5960.83691,21.598,7039.40869,-2.160,
5960.92822,21.598,7039.50049,-1.160,
5961.02002,21.598,7039.59180,-2.160,
5961.11133,21.598,7039.68311,-2.160,
5961.20313,21.598,7039.77490,-2.160,
5961.29443,21.598,7039.86621,-1.160,
5961.38623,21.598,7039.95801,-1.160,
5961.47754,21.598,7040.04932,-2.160,
5961.56934,22.598,7040.14111,-1.160,
5961.66064,22.598,7040.23242,-1.160,
5961.75195,22.598,7040.32422,-1.160,
5961.84375,21.598,7040.41553,-1.160,
5961.93506,21.598,7040.50684,-1.160,
5962.02686,21.598,7040.59863,-1.160,
5962.11816,21.598,7040.68994,-1.160,
5962.20996,22.598,7040.78174,-1.160,
5962.30127,21.598,7040.87305,-2.160,
5962.39258,22.598,7040.96484,-2.160,
5962.48438,21.598,7041.05615,-1.160,
5962.57568,21.598,7041.14746,-1.160,
5962.66748,21.598,7041.23926,-1.160,
5962.75879,21.598,7041.33057,-1.160,
5962.85059,21.598,7041.42236,-1.160,
5962.94189,21.598,7041.51367,-1.160,
5963.03320,21.598,7041.60547,-1.160,
5963.12500,21.598,7041.69678,-0.160,
5963.21631,21.598,7041.78809,-0.160,
5963.30811,21.598,7041.87988,0.840,
5963.39941,21.598,7041.97119,0.840,
5963.49121,21.598,7042.06299,0.840,
5963.58252,21.598,7042.15430,1.840,
5963.67432,20.598,7042.24609,0.840,
5963.76563,20.598,7042.33740,0.840,
5963.85693,19.598,7042.42920,0.840,
5963.94873,19.598,7042.52051,0.840,
5964.04004,19.598,7042.61182,0.840,
5964.13184,19.598,7042.70361,0.840,
5964.22314,19.598,7042.79492,-0.160,
5964.31494,18.598,7042.88672,0.840,
5964.40625,19.598,7042.97803,0.840,
5964.49756,19.598,7043.06982,-0.160,
5964.58936,19.598,7043.16113,-0.160,
5964.68066,20.598,7043.25244,-0.160,
5964.77246,19.598,7043.34424,-0.160,
5964.86377,20.598,7043.43555,-0.160,
5964.95557,20.598,7043.52734,-0.160,
5965.04688,20.598,7043.61865,-1.160,
5965.13818,20.598,7043.71045,-0.160,
5965.22998,20.598,7043.80176,-1.160,
5965.32129,20.598,7043.89307,-1.160,
5965.41309,20.598,7043.98486,-2.160,
5965.50439,20.598,7044.07617,-2.160,
5965.59619,21.598,7044.16797,-2.160,
5965.68750,20.598,7044.25928,-3.160,
5965.77930,21.598,7044.35107,-2.160,
5965.87061,21.598,7044.44238,-2.160,
5965.96191,21.598,7044.53418,-2.160,
5966.05371,20.598,7044.62549,-2.160,
5966.14502,20.598,7044.71680,-2.160,
5966.23682,20.598,7044.80859,-2.160,
5966.32813,20.598,7044.89990,-2.160,
5966.41992,21.598,7044.99170,-1.160,
5966.51123,20.598,7045.08301,-2.160,
5966.60254,21.598,7045.17480,-2.160,
5966.69434,20.598,7045.26611,-2.160,
5966.78564,21.598,7045.35742,-2.160,
5966.87744,21.598,7045.44922,-2.160,
5966.96875,20.598,7045.54053,-2.160,
5967.06055,21.598,7045.63232,-2.160,
5967.15186,21.598,7045.72363,-1.160,
5967.24316,20.598,7045.81543,-1.160,
5967.33496,20.598,7045.90674,-1.160,
5967.42627,20.598,7045.99805,-1.160,
5967.51807,20.598,7046.08984,-1.160,
5967.60938,21.598,7046.18115,-1.160,
5967.70117,20.598,7046.27295,-0.160,
5967.79248,21.598,7046.36426,-1.160,
5967.88379,20.598,7046.45605,-1.160,
5967.97559,20.598,7046.54736,-1.160,
5968.06689,20.598,7046.63916,-1.160,
5968.15869,20.598,7046.73047,-1.160,
5968.25000,20.598,7046.82178,-1.160,
5968.34180,20.598,7046.91357,-1.160,
5968.43311,20.598,7047.00488,-1.160,
5968.52490,20.598,7047.09668,-1.160,
5968.61621,20.598,7047.18799,-1.160,
5968.70752,20.598,7047.27979,-0.160,
5968.79932,19.598,7047.37109,-1.160,
5968.89063,20.598,7047.46240,-1.160,
5968.98242,20.598,7047.55420,-1.160,
5969.07373,20.598,7047.64551,-1.160,
5969.16553,20.598,7047.73730,-1.160,
5969.25684,20.598,7047.82861,-1.160,
5969.34814,20.598,7047.92041,-1.160,
5969.43994,20.598,7048.01172,-2.160,
5969.53125,21.598,7048.10303,-1.160,
5969.62305,21.598,7048.19482,-1.160,
5969.71436,20.598,7048.28613,-1.160,
5969.80615,20.598,7048.37793,-1.160,
5969.89746,20.598,7048.46924,-1.160,
5969.98877,20.598,7048.56104,-1.160,
5970.08057,20.598,7048.65234,-1.160,
5970.17188,20.598,7048.74414,-0.160,
5970.26367,20.598,7048.83545,-1.160,
5970.35498,20.598,7048.92676,-1.160,
5970.44678,20.598,7049.01855,-0.160,
5970.53809,21.598,7049.10986,-0.160,
5970.62988,20.598,7049.20166,-0.160,
5970.72119,20.598,7049.29297,-1.160,
5970.81250,20.598,7049.38477,-1.160,
5970.90430,19.598,7049.47607,-1.160,
5970.99561,20.598,7049.56738,-1.160,
5971.08740,20.598,7049.65918,-1.160,
5971.17871,20.598,7049.75049,-1.160,
5971.27051,20.598,7049.84229,-1.160,
5971.36182,20.598,7049.93359,-1.160,
5971.45313,20.598,7050.02539,-0.160,
5971.54492,20.598,7050.11670,-1.160,
5971.63623,20.598,7050.20801,-0.160,
5971.72803,20.598,7050.29980,-0.160,
5971.81934,20.598,7050.39111,-1.160,
5971.91113,20.598,7050.48291,-0.160,
5972.00244,20.598,7050.57422,-1.160,
5972.09375,20.598,7050.66602,-1.160,
5972.18555,19.598,7050.75732,-0.160,
5972.27686,20.598,7050.84912,-0.160,
5972.36865,20.598,7050.94043,-1.160,
5972.45996,20.598,7051.03174,-1.160,
5972.55176,20.598,7051.12354,-1.160,
5972.64307,20.598,7051.21484,-0.160,
5972.73486,20.598,7051.30664,-0.160,
5972.82617,20.598,7051.39795,-1.160,
5972.91748,20.598,7051.48975,-0.160,
5973.00928,20.598,7051.58105,-1.160,
5973.10059,20.598,7051.67236,-0.160,
5973.19238,20.598,7051.76416,-0.160,
5973.28369,20.598,7051.85547,-0.160,
5973.37549,19.598,7051.94727,-1.160,
5973.46680,19.598,7052.03857,-1.160,
5973.55811,19.598,7052.13037,-0.160,
5973.64990,19.598,7052.22168,-1.160,
5973.74121,19.598,7052.31299,-1.160,
5973.83301,20.598,7052.40479,-1.160,
5973.92432,20.598,7052.49609,-1.160,
5974.01611,19.598,7052.58789,-2.160,
5974.10742,19.598,7052.67920,-1.160,
5974.19873,20.598,7052.77100,-1.160,
5974.29053,20.598,7052.86230,-1.160,
5974.38184,20.598,7052.95361,-1.160,
5974.47363,20.598,7053.04541,-1.160,
5974.56494,19.598,7053.13672,-1.160,
5974.65674,20.598,7053.22852,-1.160,
5974.74805,19.598,7053.31982,-1.160,
5974.83984,20.598,7053.41162,-1.160,
5974.93115,19.598,7053.50293,-1.160,
5975.02246,20.598,7053.59473,-1.160,
5975.11426,20.598,7053.68604,-1.160,
5975.20557,20.598,7053.77734,-1.160,
5975.29736,20.598,7053.86914,-1.160,
5975.38867,20.598,7053.96045,-1.160,
5975.48047,20.598,7054.05225,-1.160,
5975.57178,19.598,7054.14355,-1.160,
5975.66309,19.598,7054.23535,-0.160,
5975.75488,19.598,7054.32666,-1.160,
5975.84619,19.598,7054.41797,-1.160,
5975.93799,20.598,7054.50977,-0.160,
5976.02930,19.598,7054.60107,-0.160,
5976.12109,20.598,7054.69287,-0.160,
5976.21240,19.598,7054.78418,-0.160,
5976.30371,19.598,7054.87598,-0.160,
5976.39551,19.598,7054.96729,-1.160,
5976.48682,19.598,7055.05859,-1.160,
5976.57861,20.598,7055.15039,-0.160,
5976.66992,19.598,7055.24170,-1.160,
5976.76172,19.598,7055.33350,-0.160,
5976.85303,20.598,7055.42480,-1.160,
5976.94482,20.598,7055.51660,-1.160,
5977.03613,19.598,7055.60791,-1.160,
5977.12744,19.598,7055.69971,-1.160,
5977.21924,19.598,7055.79102,-1.160,
5977.31055,20.598,7055.88232,-1.160,
5977.40234,19.598,7055.97412,-1.160,
5977.49365,19.598,7056.06543,-0.160,
5977.58545,19.598,7056.15723,-1.160,
5977.67676,20.598,7056.24854,-1.160,
5977.76807,19.598,7056.34033,-1.160,
5977.85986,19.598,7056.43164,-1.160,
5977.95117,19.598,7056.52295,-1.160,
5978.04297,20.598,7056.61475,-1.160,
5978.13428,19.598,7056.70605,-1.160,
5978.22607,19.598,7056.79785,-1.160,
5978.31738,20.598,7056.88916,-1.160,
5978.40869,20.598,7056.98096,-0.160,
5978.50049,19.598,7057.07227,-1.160,
5978.59180,20.598,7057.16357,-1.160,
5978.68359,19.598,7057.25537,-1.160,
5978.77490,20.598,7057.34668,-0.160,
5978.86670,20.598,7057.43848,-1.160,
5978.95801,20.598,7057.52979,-0.160,
5979.04980,20.598,7057.62158,-0.160,
5979.14111,20.598,7057.71289,-1.160,
5979.23242,19.598,7057.80469,-1.160,
5979.32422,19.598,7057.89600,-0.160,
5979.41553,20.598,7057.98730,-1.160,
5979.50732,19.598,7058.07910,-1.160,
5979.59863,19.598,7058.17041,-0.160,
5979.69043,20.598,7058.26221,-0.160,
5979.78174,20.598,7058.35352,-0.160,
5979.87305,19.598,7058.44531,-1.160,
5979.96484,20.598,7058.53662,-0.160,
5980.05615,20.598,7058.62793,-0.160,
5980.14795,19.598,7058.71973,-1.160,
5980.23926,19.598,7058.81104,-1.160,
5980.33105,20.598,7058.90283,-0.160,
5980.42236,19.598,7058.99414,-0.160,
5980.51367,19.598,7059.08594,-0.160,
5980.60547,20.598,7059.17725,-0.160,
5980.69678,19.598,7059.26855,-0.160,
5980.78857,19.598,7059.36035,-1.160,
5980.87988,19.598,7059.45166,-0.160,
5980.97168,19.598,7059.54346,-1.160,
5981.06299,19.598,7059.63477,-0.160,
5981.15430,19.598,7059.72656,-0.160,
5981.24609,19.598,7059.81787,0.840,
5981.33740,18.598,7059.90967,0.840,
5981.42920,18.598,7060.00098,0.840,
5981.52051,18.598,7060.09229,0.840,
5981.61230,19.598,7060.18408,0.840,
5981.70361,19.598,7060.27539,1.840,
5981.79541,19.598,7060.36719,0.840,
5981.88672,19.598,7060.45850,1.840,
5981.97803,19.598,7060.55029,0.840,
5982.06982,19.598,7060.64160,0.840,
5982.16113,20.598,7060.73291,1.840,
5982.25293,19.598,7060.82471,0.840,
5982.34424,20.598,7060.91602,0.840,
5982.43604,20.598,7061.00781,0.840,
5982.52734,20.598,7061.09912,0.840,
5982.61865,19.598,7061.19092,-0.160,
5982.71045,20.598,7061.28223,-0.160,
5982.80176,19.598,7061.37354,-0.160,
5982.89355,19.598,7061.46533,-0.160,
5982.98486,19.598,7061.55664,-0.160,
5983.07666,19.598,7061.64844,-0.160,
5983.16797,19.598,7061.73975,-0.160,
5983.25928,19.598,7061.83154,-0.160,
5983.35107,20.598,7061.92285,-0.160,
5983.44238,19.598,7062.01465,-1.160,
5983.53418,19.598,7062.10596,-1.160,
5983.62549,19.598,7062.19727,-2.160,
5983.71729,20.598,7062.28906,-2.160,
5983.80859,19.598,7062.38037,-3.160,
5983.90039,19.598,7062.47217,-3.160,
5983.99170,20.598,7062.56348,-3.160,
5984.08301,19.598,7062.65527,-4.160,
5984.17480,19.598,7062.74658,-4.160,
5984.26611,20.598,7062.83789,-3.160,
5984.35791,19.598,7062.92969,-3.160,
5984.44922,19.598,7063.02100,-4.160,
5984.54102,19.598,7063.11279,-3.160,
5984.63232,19.598,7063.20410,-2.160,
5984.72363,19.598,7063.29590,-2.160,
5984.81543,19.598,7063.38721,-1.160,
5984.90674,20.598,7063.47852,-2.160,
5984.99854,19.598,7063.57031,-2.160,
5985.08984,19.598,7063.66162,-2.160,
5985.18164,19.598,7063.75342,-1.160,
5985.27295,19.598,7063.84473,-1.160,
5985.36426,19.598,7063.93652,-1.160,
5985.45605,20.598,7064.02783,-1.160,
5985.54736,19.598,7064.11914,-1.160,
5985.63916,19.598,7064.21094,-1.160,
5985.73047,19.598,7064.30225,-1.160,
5985.82227,20.598,7064.39404,-1.160,
5985.91357,19.598,7064.48535,-1.160,
5986.00537,19.598,7064.57715,-1.160,
5986.09668,19.598,7064.66846,-1.160,
5986.18799,19.598,7064.76025,-1.160,
5986.27979,19.598,7064.85156,-0.160,
5986.37109,19.598,7064.94287,-1.160,
5986.46289,19.598,7065.03467,-0.160,
5986.55420,19.598,7065.12598,-0.160,
5986.64600,19.598,7065.21777,-1.160,
5986.73730,19.598,7065.30908,-0.160,
5986.82861,19.598,7065.40088,-0.160,
5986.92041,19.598,7065.49219,-0.160,
5987.01172,19.598,7065.58350,-0.160,
5987.10352,20.598,7065.67529,-0.160,
5987.19482,19.598,7065.76660,-1.160,
5987.28662,19.598,7065.85840,-0.160,
5987.37793,19.598,7065.94971,-1.160,
5987.46924,19.598,7066.04150,-1.160,
5987.56104,19.598,7066.13281,-0.160,
5987.65234,19.598,7066.22412,-0.160,
5987.74414,19.598,7066.31592,-0.160,
5987.83545,19.598,7066.40723,-0.160,
5987.92725,19.598,7066.49902,-0.160,
5988.01855,19.598,7066.59033,-0.160,
5988.11035,19.598,7066.68213,-0.160,
5988.20166,19.598,7066.77344,-1.160,
5988.29297,19.598,7066.86523,-0.160,
5988.38477,19.598,7066.95654,-0.160,
5988.47607,19.598,7067.04785,-0.160,
5988.56787,19.598,7067.13965,-0.160,
5988.65918,19.598,7067.23096,-0.160,
5988.75098,19.598,7067.32275,-0.160,
5988.84229,19.598,7067.41406,-0.160,
5988.93359,19.598,7067.50586,-0.160,
5989.02539,19.598,7067.59717,-0.160,
5989.11670,19.598,7067.68848,-0.160,
5989.20850,19.598,7067.78027,0.840,
5989.29980,19.598,7067.87158,-0.160,
5989.39160,19.598,7067.96338,-0.160,
5989.48291,19.598,7068.05469,-0.160,
5989.57422,19.598,7068.14648,-0.160,
5989.66602,19.598,7068.23779,-0.160,
5989.75732,19.598,7068.32910,-0.160,
5989.84912,19.598,7068.42090,-0.160,
5989.94043,19.598,7068.51221,-0.160,
5990.03223,20.598,7068.60400,-0.160,
5990.12354,19.598,7068.69531,-1.160,
5990.21533,20.598,7068.78711,-1.160,
5990.30664,19.598,7068.87842,-1.160,
5990.39795,19.598,7068.97021,-1.160,
5990.48975,19.598,7069.06152,-1.160,
5990.58105,19.598,7069.15283,-0.160,
5990.67285,19.598,7069.24463,-0.160,
5990.76416,19.598,7069.33594,-0.160,
5990.85596,19.598,7069.42773,-1.160,
5990.94727,19.598,7069.51904,-0.160,
5991.03857,19.598,7069.61084,-0.160,
5991.13037,19.598,7069.70215,-0.160,
5991.22168,19.598,7069.79346,-1.160,
5991.31348,19.598,7069.88525,-0.160,
5991.40479,19.598,7069.97656,-0.160,
5991.49658,20.598,7070.06836,-0.160,
5991.58789,19.598,7070.15967,-1.160,
5991.67920,19.598,7070.25146,-0.160,
5991.77100,19.598,7070.34277,-0.160,
5991.86230,19.598,7070.43408,-1.160,
5991.95410,19.598,7070.52588,-0.160,
5992.04541,19.598,7070.61719,-0.160,
5992.13721,19.598,7070.70898,-0.160,
5992.22852,19.598,7070.80029,-0.160,
5992.31982,19.598,7070.89209,-1.160,
5992.41162,19.598,7070.98340,-0.160,
5992.50293,19.598,7071.07520,-0.160,
5992.59473,19.598,7071.16650,-0.160,
5992.68604,19.598,7071.25781,-1.160,
5992.77783,18.598,7071.34961,-0.160,
5992.86914,19.598,7071.44092,-0.160,
5992.96094,19.598,7071.53271,-1.160,
5993.05225,19.598,7071.62402,-1.160,
5993.14355,19.598,7071.71582,-1.160,
5993.23535,19.598,7071.80713,-1.160,
5993.32666,19.598,7071.89844,-1.160,
5993.41846,19.598,7071.99023,-1.160,
5993.50977,19.598,7072.08154,-1.160,
5993.60156,19.598,7072.17334,-0.160,
5993.69287,19.598,7072.26465,-0.160,
5993.78418,19.598,7072.35645,-0.160,
5993.87598,19.598,7072.44775,-0.160,
5993.96729,19.598,7072.53906,-0.160,
5994.05908,19.598,7072.63086,-0.160,
5994.15039,19.598,7072.72217,-1.160,
5994.24219,19.598,7072.81396,-1.160,
5994.33350,19.598,7072.90527,-1.160,
5994.42480,20.598,7072.99707,-0.160,
5994.51660,19.598,7073.08838,-1.160,
5994.60791,19.598,7073.18018,-1.160,
5994.69971,19.598,7073.27148,-0.160,
5994.79102,19.598,7073.36279,-1.160,
5994.88281,19.598,7073.45459,-1.160,
5994.97412,19.598,7073.54590,-0.160,
5995.06592,19.598,7073.63770,-0.160,
5995.15723,19.598,7073.72900,-1.160,
5995.24854,19.598,7073.82080,-1.160,
5995.34033,19.598,7073.91211,-0.160,
5995.43164,19.598,7074.00342,-0.160,
5995.52344,18.598,7074.09521,-1.160,
5995.61475,19.598,7074.18652,-0.160,
5995.70654,19.598,7074.27832,-0.160,
5995.79785,19.598,7074.36963,-1.160,
5995.88916,19.598,7074.46143,-0.160,
5995.98096,19.598,7074.55273,-0.160,
5996.07227,19.598,7074.64404,-0.160,
5996.16406,19.598,7074.73584,-1.160,
5996.25537,19.598,7074.82715,-0.160,
5996.34717,19.598,7074.91895,-0.160,
5996.43848,19.598,7075.01025,-1.160,
5996.52979,19.598,7075.10205,0.840,
5996.62158,19.598,7075.19336,-0.160,
5996.71289,19.598,7075.28516,-1.160,
5996.80469,19.598,7075.37646,-0.160,
5996.89600,19.598,7075.46777,-0.160,
5996.98779,19.598,7075.55957,-0.160,
5997.07910,19.598,7075.65088,-0.160,
5997.17090,19.598,7075.74268,-1.160,
5997.26221,19.598,7075.83398,-0.160,
5997.35352,19.598,7075.92578,-1.160,
5997.44531,19.598,7076.01709,-1.160,
5997.53662,19.598,7076.10840,-0.160,
5997.62842,19.598,7076.20020,-1.160,
5997.71973,19.598,7076.29150,-0.160,
5997.81152,19.598,7076.38330,-0.160,
5997.90283,19.598,7076.47461,-1.160,
5997.99414,19.598,7076.56641,-0.160,
5998.08594,19.598,7076.65771,-0.160,
5998.17725,19.598,7076.74902,-0.160,
5998.26904,19.598,7076.84082,-1.160,
5998.36035,19.598,7076.93213,-0.160,
5998.45215,19.598,7077.02393,-0.160,
5998.54346,19.598,7077.11523,-0.160,
5998.63477,18.598,7077.20703,-0.160,
5998.72656,18.598,7077.29834,-0.160,
5998.81787,18.598,7077.38965,-1.160,
5998.90967,19.598,7077.48145,-1.160,
5999.00098,19.598,7077.57275,-0.160,
5999.09277,19.598,7077.66455,-0.160,
5999.18408,19.598,7077.75586,-0.160,
5999.27588,20.598,7077.84766,-0.160,
5999.36719,20.598,7077.93896,-0.160,
5999.45850,19.598,7078.03076,-0.160,
5999.55029,19.598,7078.12207,-0.160,
5999.64160,20.598,7078.21338,0.840,
5999.73340,19.598,7078.30518,-0.160,
5999.82471,19.598,7078.39648,0.840,
5999.91650,19.598,7078.48828,0.840,
6000.00781,19.598,7078.57959,0.840,
6000.09912,19.598,7078.67139,-0.160,
6000.19092,19.598,7078.76270,0.840,
6000.28223,19.598,7078.85400,-0.160,
6000.37402,19.598,7078.94580,-0.160,
6000.46533,19.598,7079.03711,-0.160,
6000.55713,19.598,7079.12891,-0.160,
6000.64844,19.598,7079.22021,-0.160,
6000.73975,19.598,7079.31201,-0.160,
6000.83154,19.598,7079.40332,-0.160,
6000.92285,18.598,7079.49463,0.840,
6001.01465,19.598,7079.58643,-0.160,
6001.10596,18.598,7079.67773,-0.160,
6001.19775,19.598,7079.76953,-0.160,
6001.28906,19.598,7079.86084,-0.160,
6001.38086,19.598,7079.95264,-1.160,
6001.47217,18.598,7080.04395,-0.160,
6001.56348,19.598,7080.13574,-1.160,
6001.65527,18.598,7080.22705,-1.160,
6001.74658,19.598,7080.31836,-2.160,
6001.83838,19.598,7080.41016,-2.160,
6001.92969,19.598,7080.50146,-3.160,
6002.02148,19.598,7080.59326,-3.160,
6002.11279,18.598,7080.68457,-4.160,
6002.20410,19.598,7080.77637,-4.160,
6002.29590,19.598,7080.86768,-4.160,
6002.38721,19.598,7080.95898,-3.160,
6002.47900,19.598,7081.05078,-5.160,
6002.57031,19.598,7081.14209,-4.160,
6002.66211,19.598,7081.23389,-3.160,
6002.75342,19.598,7081.32520,-3.160,
6002.84473,18.598,7081.41699,-3.160,
6002.93652,19.598,7081.50830,-2.160,
6003.02783,18.598,7081.59961,-2.160,
6003.11963,19.598,7081.69141,-2.160,
6003.21094,19.598,7081.78271,-2.160,
6003.30273,19.598,7081.87451,-2.160,
6003.39404,18.598,7081.96582,-1.160,
6003.48584,18.598,7082.05762,-2.160,
6003.57715,19.598,7082.14893,-1.160,
6003.66846,19.598,7082.24072,-1.160,
6003.76025,19.598,7082.33203,-1.160,
6003.85156,19.598,7082.42334,-0.160,
6003.94336,19.598,7082.51514,-0.160,
6004.03467,18.598,7082.60645,-1.160,
6004.12646,19.598,7082.69824,-1.160,
6004.21777,19.598,7082.78955,-1.160,
6004.30908,18.598,7082.88135,-1.160,
6004.40088,18.598,7082.97266,-0.160,
6004.49219,19.598,7083.06396,-0.160,
6004.58398,19.598,,,
6004.67529,19.598,,,
6004.76709,19.598,,,
6004.85840,19.598,,,
6004.94971,19.598,,,
6005.04150,18.598,,,
6005.13281,19.598,,,
6005.22461,19.598,,,
6005.31592,19.598,,,
6005.40771,18.598,,,
6005.49902,19.598,,,
6005.59033,18.598,,,
6005.68213,18.598,,,
6005.77344,18.598,,,
6005.86523,18.598,,,
6005.95654,18.598,,,
6006.04834,18.598,,,
6006.13965,19.598,,,
6006.23145,18.598,,,
6006.32275,19.598,,,
6006.41406,19.598,,,
6006.50586,19.598,,,
6006.59717,19.598,,,
6006.68896,19.598,,,
6006.78027,19.598,,,
6006.87207,19.598,,,
6006.96338,19.598,,,
6007.05469,19.598,,,
6007.14648,19.598,,,
6007.23779,18.598,,,
6007.32959,19.598,,,
6007.42090,19.598,,,
6007.51270,19.598,,,
6007.60400,19.598,,,
6007.69531,19.598,,,
6007.78711,19.598,,,
6007.87842,19.598,,,
6007.97021,19.598,,,
6008.06152,18.598,,,
6008.15332,19.598,,,
6008.24463,19.598,,,
6008.33643,19.598,,,
6008.42773,18.598,,,
6008.51904,18.598,,,
6008.61084,19.598,,,
6008.70215,18.598,,,
6008.79395,18.598,,,
6008.88525,18.598,,,
6008.97705,18.598,,,
6009.06836,19.598,,,
6009.15967,19.598,,,
6009.25146,19.598,,,
6009.34277,19.598,,,
6009.43457,19.598,,,
6009.52588,19.598,,,
6009.61768,19.598,,,
6009.70898,18.598,,,
6009.80029,19.598,,,
6009.89209,18.598,,,
6009.98340,19.598,,,
6010.07520,19.598,,,
6010.16650,19.598,,,
6010.25830,18.598,,,
6010.34961,19.598,,,
6010.44141,18.598,,,
6010.53271,19.598,,,
6010.62402,18.598,,,
6010.71582,19.598,,,
6010.80713,18.598,,,
6010.89893,19.598,,,
6010.99023,19.598,,,
6011.08203,19.598,,,
6011.17334,19.598,,,
6011.26465,19.598,,,
6011.35645,18.598,,,
6011.44775,18.598,,,
6011.53955,18.598,,,
6011.63086,18.598,,,
6011.72266,19.598,,,
6011.81396,18.598,,,
6011.90527,19.598,,,
6011.99707,18.598,,,
6012.08838,19.598,,,
6012.18018,19.598,,,
6012.27148,19.598,,,
6012.36328,18.598,,,
6012.45459,18.598,,,
6012.54639,19.598,,,
6012.63770,18.598,,,
6012.72900,19.598,,,
6012.82080,19.598,,,
6012.91211,18.598,,,
6013.00391,18.598,,,
6013.09521,18.598,,,
6013.18701,18.598,,,
6013.27832,18.598,,,
6013.36963,18.598,,,
6013.46143,19.598,,,
6013.55273,18.598,,,
6013.64453,19.598,,,
6013.73584,19.598,,,
6013.82764,18.598,,,
6013.91895,18.598,,,
6014.01025,18.598,,,
6014.10205,18.598,,,
6014.19336,18.598,,,
6014.28516,18.598,,,
6014.37646,18.598,,,
6014.46826,18.598,,,
6014.55957,18.598,,,
6014.65137,18.598,,,
6014.74268,18.598,,,
6014.83398,18.598,,,
6014.92578,19.598,,,
6015.01709,18.598,,,
6015.10889,18.598,,,
6015.20020,18.598,,,
6015.29199,18.598,,,
6015.38330,18.598,,,
6015.47461,19.598,,,
6015.56641,19.598,,,
6015.65771,19.598,,,
6015.74951,19.598,,,
6015.84082,19.598,,,
6015.93262,18.598,,,
6016.02393,18.598,,,
6016.11523,18.598,,,
6016.20703,18.598,,,
6016.29834,18.598,,,
6016.39014,18.598,,,
6016.48145,18.598,,,
6016.57324,18.598,,,
6016.66455,18.598,,,
6016.75586,18.598,,,
6016.84766,19.598,,,
6016.93896,19.598,,,
6017.03076,19.598,,,
6017.12207,19.598,,,
6017.21387,18.598,,,
6017.30518,19.598,,,
6017.39697,19.598,,,
6017.48828,19.598,,,
6017.57959,19.598,,,
6017.67139,19.598,,,
6017.76270,19.598,,,
6017.85449,20.598,,,
6017.94580,19.598,,,
6018.03760,19.598,,,
6018.12891,19.598,,,
6018.22021,19.598,,,
6018.31201,19.598,,,
6018.40332,19.598,,,
6018.49512,19.598,,,
6018.58643,19.598,,,
6018.67822,18.598,,,
6018.76953,18.598,,,
6018.86084,18.598,,,
6018.95264,19.598,,,
6019.04395,18.598,,,
6019.13574,19.598,,,
6019.22705,18.598,,,
6019.31885,19.598,,,
6019.41016,19.598,,,
6019.50195,19.598,,,
6019.59326,18.598,,,
6019.68457,19.598,,,
6019.77637,19.598,,,
6019.86768,18.598,,,
6019.95947,19.598,,,
6020.05078,18.598,,,
6020.14258,19.598,,,
6020.23389,18.598,,,
6020.32520,18.598,,,
6020.41699,18.598,,,
6020.50830,18.598,,,
6020.60010,18.598,,,
6020.69141,19.598,,,
6020.78320,19.598,,,
6020.87451,19.598,,,
6020.96582,19.598,,,
6021.05762,19.598,,,
6021.14893,19.598,,,
6021.24072,18.598,,,
6021.33203,19.598,,,
6021.42383,19.598,,,
6021.51514,18.598,,,
6021.60693,18.598,,,
6021.69824,19.598,,,
6021.78955,18.598,,,
6021.88135,18.598,,,
6021.97266,18.598,,,
6022.06445,19.598,,,
6022.15576,18.598,,,
6022.24756,19.598,,,
6022.33887,19.598,,,
6022.43018,19.598,,,
6022.52197,19.598,,,
6022.61328,19.598,,,
6022.70508,18.598,,,
6022.79639,19.598,,,
6022.88818,19.598,,,
6022.97949,19.598,,,
6023.07080,18.598,,,
6023.16260,18.598,,,
6023.25391,18.598,,,
6023.34570,18.598,,,
6023.43701,19.598,,,
6023.52881,19.598,,,
6023.62012,18.598,,,
6023.71191,19.598,,,
6023.80322,18.598,,,
6023.89453,19.598,,,
6023.98633,19.598,,,
6024.07764,18.598,,,
6024.16943,19.598,,,
6024.26074,19.598,,,
6024.35254,19.598,,,
6024.44385,19.598,,,
6024.53516,18.598,,,
6024.62695,18.598,,,
6024.71826,19.598,,,
6024.81006,19.598,,,
6024.90137,19.598,,,
6024.99316,19.598,,,
6025.08447,19.598,,,
6025.17578,19.598,,,
6025.26758,19.598,,,
6025.35889,19.598,,,
6025.45068,19.598,,,
6025.54199,18.598,,,
6025.63379,19.598,,,
6025.72510,18.598,,,
6025.81689,19.598,,,
6025.90820,19.598,,,
6025.99951,19.598,,,
6026.09131,18.598,,,
6026.18262,19.598,,,
6026.27441,18.598,,,
6026.36572,18.598,,,
6026.45752,18.598,,,
6026.54883,19.598,,,
6026.64014,19.598,,,
6026.73193,19.598,,,
6026.82324,19.598,,,
6026.91504,19.598,,,
6027.00635,18.598,,,
6027.09814,19.598,,,
6027.18945,19.598,,,
6027.28076,19.598,,,
6027.37256,18.598,,,
6027.46387,19.598,,,
6027.55566,19.598,,,
6027.64697,18.598,,,
6027.73877,19.598,,,
6027.83008,18.598,,,
6027.92188,19.598,,,
6028.01318,18.598,,,
6028.10449,19.598,,,
6028.19629,19.598,,,
6028.28760,18.598,,,
6028.37939,19.598,,,
6028.47070,19.598,,,
6028.56250,19.598,,,
6028.65381,19.598,,,
6028.74512,19.598,,,
6028.83691,19.598,,,
6028.92822,19.598,,,
6029.02002,19.598,,,
6029.11133,19.598,,,
6029.20313,18.598,,,
6029.29443,18.598,,,
6029.38574,18.598,,,
6029.47754,18.598,,,
6029.56885,19.598,,,
6029.66064,19.598,,,
6029.75195,19.598,,,
6029.84375,19.598,,,
6029.93506,19.598,,,
6030.02637,19.598,,,
6030.11816,19.598,,,
6030.20947,19.598,,,
6030.30127,19.598,,,
6030.39258,18.598,,,
6030.48438,18.598,,,
6030.57568,18.598,,,
6030.66748,19.598,,,
6030.75879,18.598,,,
6030.85010,19.598,,,
6030.94189,19.598,,,
6031.03320,19.598,,,
6031.12500,18.598,,,
6031.21631,18.598,,,
6031.30811,18.598,,,
6031.39941,18.598,,,
6031.49072,19.598,,,
6031.58252,19.598,,,
6031.67383,19.598,,,
6031.76563,18.598,,,
6031.85693,19.598,,,
6031.94873,19.598,,,
6032.04004,19.598,,,
6032.13135,18.598,,,
6032.22314,19.598,,,
6032.31445,18.598,,,
6032.40625,19.598,,,
6032.49756,19.598,,,
6032.58936,19.598,,,
6032.68066,19.598,,,
6032.77246,19.598,,,
6032.86377,18.598,,,
6032.95508,19.598,,,
6033.04688,19.598,,,
6033.13818,18.598,,,
6033.22998,19.598,,,
6033.32129,18.598,,,
6033.41309,19.598,,,
6033.50439,18.598,,,
6033.59570,19.598,,,
6033.68750,18.598,,,
6033.77881,18.598,,,
6033.87061,19.598,,,
6033.96191,19.598,,,
6034.05371,19.598,,,
6034.14502,19.598,,,
6034.23633,19.598,,,
6034.32813,19.598,,,
6034.41943,19.598,,,
6034.51123,19.598,,,
6034.60254,19.598,,,
6034.69434,19.598,,,
6034.78564,19.598,,,
6034.87744,19.598,,,
6034.96875,19.598,,,
6035.06006,18.598,,,
6035.15186,19.598,,,
6035.24316,18.598,,,
6035.33496,18.598,,,
6035.42627,19.598,,,
6035.51807,19.598,,,
6035.60938,18.598,,,
6035.70068,18.598,,,
6035.79248,19.598,,,
6035.88379,19.598,,,
6035.97559,19.598,,,
6036.06689,19.598,,,
6036.15869,18.598,,,
6036.25000,18.598,,,
6036.34131,19.598,,,
6036.43311,19.598,,,
6036.52441,18.598,,,
6036.61621,18.598,,,
6036.70752,19.598,,,
6036.79932,19.598,,,
6036.89063,18.598,,,
6036.98242,19.598,,,
6037.07373,19.598,,,
6037.16504,18.598,,,
6037.25684,18.598,,,
6037.34814,18.598,,,
6037.43994,18.598,,,
6037.53125,18.598,,,
6037.62305,19.598,,,
6037.71436,18.598,,,
6037.80566,18.598,,,
6037.89746,18.598,,,
6037.98877,18.598,,,
6038.08057,18.598,,,
6038.17188,18.598,,,
6038.26367,19.598,,,
6038.35498,19.598,,,
6038.44629,18.598,,,
6038.53809,18.598,,,
6038.62939,18.598,,,
6038.72119,18.598,,,
6038.81250,18.598,,,
6038.90430,18.598,,,
6038.99561,18.598,,,
6039.08740,18.598,,,
6039.17871,18.598,,,
6039.27002,18.598,,,
6039.36182,18.598,,,
6039.45313,18.598,,,
6039.54492,18.598,,,
6039.63623,18.598,,,
6039.72803,18.598,,,
6039.81934,19.598,,,
6039.91064,18.598,,,
6040.00244,19.598,,,
6040.09375,19.598,,,
6040.18555,19.598,,,
6040.27686,18.598,,,
6040.36865,18.598,,,
6040.45996,18.598,,,
6040.55127,19.598,,,
6040.64307,18.598,,,
6040.73438,18.598,,,
6040.82617,18.598,,,
6040.91748,18.598,,,
6041.00928,18.598,,,
6041.10059,18.598,,,
6041.19238,18.598,,,
6041.28369,19.598,,,
6041.37500,18.598,,,
6041.46680,18.598,,,
6041.55811,19.598,,,
6041.64990,18.598,,,
6041.74121,19.598,,,
6041.83301,19.598,,,
6041.92432,18.598,,,
6042.01563,18.598,,,
6042.10742,18.598,,,
6042.19873,18.598,,,
6042.29053,18.598,,,
6042.38184,18.598,,,
6042.47363,18.598,,,
6042.56494,19.598,,,
6042.65625,18.598,,,
6042.74805,19.598,,,
6042.83936,18.598,,,
6042.93115,18.598,,,
6043.02246,18.598,,,
6043.11426,18.598,,,
6043.20557,18.598,,,
6043.29688,18.598,,,
6043.38867,19.598,,,
6043.47998,18.598,,,
6043.57178,18.598,,,
6043.66309,18.598,,,
6043.75488,18.598,,,
6043.84619,18.598,,,
6043.93799,18.598,,,
6044.02930,18.598,,,
6044.12061,18.598,,,
6044.21240,18.598,,,
6044.30371,18.598,,,
6044.39551,18.598,,,
6044.48682,18.598,,,
6044.57861,18.598,,,
6044.66992,18.598,,,
6044.76123,19.598,,,
6044.85303,19.598,,,
6044.94434,18.598,,,
6045.03613,19.598,,,
6045.12744,18.598,,,
6045.21924,18.598,,,
6045.31055,18.598,,,
6045.40186,18.598,,,
6045.49365,18.598,,,
6045.58496,18.598,,,
6045.67676,18.598,,,
6045.76807,18.598,,,
6045.85986,19.598,,,
6045.95117,18.598,,,
6046.04297,18.598,,,
6046.13428,18.598,,,
6046.22559,18.598,,,
6046.31738,18.598,,,
6046.40869,18.598,,,
6046.50049,18.598,,,
6046.59180,18.598,,,
6046.68359,18.598,,,
6046.77490,18.598,,,
6046.86621,18.598,,,
6046.95801,18.598,,,
6047.04932,18.598,,,
6047.14111,18.598,,,
6047.23242,18.598,,,
6047.32422,18.598,,,
6047.41553,18.598,,,
6047.50684,17.598,,,
6047.59863,18.598,,,
6047.68994,17.598,,,
6047.78174,18.598,,,
6047.87305,18.598,,,
6047.96484,17.598,,,
6048.05615,18.598,,,
6048.14795,18.598,,,
6048.23926,17.598,,,
6048.33057,17.598,,,
6048.42236,17.598,,,
6048.51367,18.598,,,
6048.60547,18.598,,,
6048.69678,18.598,,,
6048.78857,17.598,,,
6048.87988,17.598,,,
6048.97119,18.598,,,
6049.06299,18.598,,,
6049.15430,18.598,,,
6049.24609,18.598,,,
6049.33740,18.598,,,
6049.42920,18.598,,,
6049.52051,18.598,,,
6049.61182,18.598,,,
6049.70361,18.598,,,
6049.79492,18.598,,,
6049.88672,18.598,,,
6049.97803,18.598,,,
6050.06982,18.598,,,
6050.16113,18.598,,,
6050.25293,18.598,,,
6050.34424,17.598,,,
6050.43555,17.598,,,
6050.52734,17.598,,,
6050.61865,18.598,,,
6050.71045,18.598,,,
6050.80176,18.598,,,
6050.89355,18.598,,,
6050.98486,18.598,,,
6051.07617,19.598,,,
6051.16797,19.598,,,
6051.25928,19.598,,,
6051.35107,19.598,,,
6051.44238,20.598,,,
6051.53418,20.598,,,
6051.62549,19.598,,,
6051.71680,19.598,,,
6051.80859,19.598,,,
6051.89990,18.598,,,
6051.99170,18.598,,,
6052.08301,18.598,,,
6052.17480,18.598,,,
6052.26611,17.598,,,
6052.35791,18.598,,,
6052.44922,18.598,,,
6052.54053,17.598,,,
6052.63232,18.598,,,
6052.72363,17.598,,,
6052.81543,17.598,,,
6052.90674,18.598,,,
6052.99854,18.598,,,
6053.08984,18.598,,,
6053.18115,17.598,,,
6053.27295,18.598,,,
6053.36426,18.598,,,
6053.45605,18.598,,,
6053.54736,18.598,,,
6053.63916,18.598,,,
6053.73047,17.598,,,
6053.82178,18.598,,,
6053.91357,18.598,,,
6054.00488,18.598,,,
6054.09668,17.598,,,
6054.18799,17.598,,,
6054.27979,18.598,,,
6054.37109,17.598,,,
6054.46240,18.598,,,
6054.55420,18.598,,,
6054.64551,17.598,,,
6054.73730,18.598,,,
6054.82861,18.598,,,
6054.92041,18.598,,,
6055.01172,17.598,,,
6055.10352,18.598,,,
6055.19482,18.598,,,
6055.28613,17.598,,,
6055.37793,17.598,,,
6055.46924,18.598,,,
6055.56104,18.598,,,
6055.65234,18.598,,,
6055.74414,18.598,,,
6055.83545,18.598,,,
6055.92676,18.598,,,
6056.01855,18.598,,,
6056.10986,18.598,,,
6056.20166,18.598,,,
6056.29297,18.598,,,
6056.38477,18.598,,,
6056.47607,18.598,,,
6056.56738,18.598,,,
6056.65918,18.598,,,
6056.75049,18.598,,,
6056.84229,18.598,,,
6056.93359,18.598,,,
6057.02539,17.598,,,
6057.11670,17.598,,,
6057.20850,17.598,,,
6057.29980,17.598,,,
6057.39111,18.598,,,
6057.48291,17.598,,,
6057.57422,18.598,,,
6057.66602,18.598,,,
6057.75732,17.598,,,
6057.84912,17.598,,,
6057.94043,17.598,,,
6058.03174,18.598,,,
6058.12354,17.598,,,
6058.21484,18.598,,,
6058.30664,17.598,,,
6058.39795,18.598,,,
6058.48975,18.598,,,
6058.58105,18.598,,,
6058.67236,17.598,,,
6058.76416,18.598,,,
6058.85547,18.598,,,
6058.94727,18.598,,,
6059.03857,18.598,,,
6059.13037,18.598,,,
6059.22168,17.598,,,
6059.31348,17.598,,,
6059.40479,18.598,,,
6059.49609,18.598,,,
6059.58789,17.598,,,
6059.67920,17.598,,,
6059.77100,17.598,,,
6059.86230,17.598,,,
6059.95410,17.598,,,
6060.04541,17.598,,,
6060.13672,17.598,,,
6060.22852,17.598,,,
6060.31982,18.598,,,
6060.41162,18.598,,,
6060.50293,17.598,,,
6060.59473,17.598,,,
6060.68604,17.598,,,
6060.77734,16.598,,,
6060.86914,17.598,,,
6060.96045,17.598,,,
6061.05225,17.598,,,
6061.14355,17.598,,,
6061.23535,17.598,,,
6061.32666,17.598,,,
6061.41846,17.598,,,
6061.50977,17.598,,,
6061.60107,17.598,,,
6061.69287,17.598,,,
6061.78418,17.598,,,
6061.87598,17.598,,,
6061.96729,17.598,,,
6062.05908,17.598,,,
6062.15039,18.598,,,
6062.24170,17.598,,,
6062.33350,17.598,,,
6062.42480,17.598,,,
6062.51660,18.598,,,
6062.60791,17.598,,,
6062.69971,17.598,,,
6062.79102,17.598,,,
6062.88232,17.598,,,
6062.97412,17.598,,,
6063.06543,17.598,,,
6063.15723,17.598,,,
6063.24854,18.598,,,
6063.34033,17.598,,,
6063.43164,18.598,,,
6063.52344,17.598,,,
6063.61475,17.598,,,
6063.70605,17.598,,,
6063.79785,17.598,,,
6063.88916,17.598,,,
6063.98096,17.598,,,
6064.07227,17.598,,,
6064.16406,17.598,,,
6064.25537,17.598,,,
6064.34668,17.598,,,
6064.43848,17.598,,,
6064.52979,17.598,,,
6064.62158,17.598,,,
6064.71289,18.598,,,
6064.80469,17.598,,,
6064.89600,17.598,,,
6064.98730,17.598,,,
6065.07910,17.598,,,
6065.17041,17.598,,,
6065.26221,17.598,,,
6065.35352,17.598,,,
6065.44531,17.598,,,
6065.53662,17.598,,,
6065.62842,17.598,,,
6065.71973,17.598,,,
6065.81104,17.598,,,
6065.90283,17.598,,,
6065.99414,17.598,,,
6066.08594,17.598,,,
6066.17725,18.598,,,
6066.26904,17.598,,,
6066.36035,17.598,,,
6066.45166,17.598,,,
6066.54346,17.598,,,
6066.63477,17.598,,,
6066.72656,17.598,,,
6066.81787,18.598,,,
6066.90967,17.598,,,
6067.00098,17.598,,,
6067.09229,17.598,,,
6067.18408,17.598,,,
6067.27539,17.598,,,
6067.36719,17.598,,,
6067.45850,17.598,,,
6067.55029,17.598,,,
6067.64160,18.598,,,
6067.73291,17.598,,,
6067.82471,17.598,,,
6067.91602,17.598,,,
6068.00781,18.598,,,
6068.09912,17.598,,,
6068.19092,17.598,,,
6068.28223,17.598,,,
6068.37402,16.598,,,
6068.46533,16.598,,,
6068.55664,16.598,,,
6068.64844,16.598,,,
6068.73975,16.598,,,
6068.83154,16.598,,,
6068.92285,17.598,,,
6069.01465,17.598,,,
6069.10596,17.598,,,
6069.19727,17.598,,,
6069.28906,17.598,,,
6069.38037,17.598,,,
6069.47217,17.598,,,
6069.56348,17.598,,,
6069.65527,17.598,,,
6069.74658,17.598,,,
6069.83789,17.598,,,
6069.92969,17.598,,,
6070.02100,17.598,,,
6070.11279,17.598,,,
6070.20410,17.598,,,
6070.29590,17.598,,,
6070.38721,17.598,,,
6070.47900,17.598,,,
6070.57031,17.598,,,
6070.66162,17.598,,,
6070.75342,17.598,,,
6070.84473,17.598,,,
6070.93652,17.598,,,
6071.02783,17.598,,,
6071.11963,17.598,,,
6071.21094,17.598,,,
6071.30225,17.598,,,
6071.39404,17.598,,,
6071.48535,17.598,,,
6071.57715,16.598,,,
6071.66846,17.598,,,
6071.76025,17.598,,,
6071.85156,17.598,,,
6071.94287,17.598,,,
6072.03467,18.598,,,
6072.12598,17.598,,,
6072.21777,17.598,,,
6072.30908,17.598,,,
6072.40088,17.598,,,
6072.49219,17.598,,,
6072.58398,17.598,,,
6072.67529,17.598,,,
6072.76660,17.598,,,
6072.85840,17.598,,,
6072.94971,17.598,,,
6073.04150,17.598,,,
6073.13281,17.598,,,
6073.22461,17.598,,,
6073.31592,17.598,,,
6073.40723,17.598,,,
6073.49902,17.598,,,
6073.59033,17.598,,,
6073.68213,17.598,,,
6073.77344,17.598,,,
6073.86523,17.598,,,
6073.95654,17.598,,,
6074.04785,17.598,,,
6074.13965,17.598,,,
6074.23096,17.598,,,
6074.32275,17.598,,,
6074.41406,17.598,,,
6074.50586,17.598,,,
6074.59717,17.598,,,
6074.68896,17.598,,,
6074.78027,17.598,,,
6074.87158,17.598,,,
6074.96338,17.598,,,
6075.05469,17.598,,,
6075.14648,17.598,,,
6075.23779,17.598,,,
6075.32959,17.598,,,
6075.42090,17.598,,,
6075.51221,17.598,,,
6075.60400,17.598,,,
6075.69531,17.598,,,
6075.78711,16.598,,,
6075.87842,17.598,,,
6075.97021,17.598,,,
6076.06152,17.598,,,
6076.15283,17.598,,,
6076.24463,17.598,,,
6076.33594,17.598,,,
6076.42773,17.598,,,
6076.51904,17.598,,,
6076.61084,17.598,,,
6076.70215,17.598,,,
6076.79395,17.598,,,
6076.88525,17.598,,,
6076.97656,17.598,,,
6077.06836,17.598,,,
6077.15967,17.598,,,
6077.25146,17.598,,,
6077.34277,17.598,,,
6077.43457,17.598,,,
6077.52588,17.598,,,
6077.61719,17.598,,,
6077.70898,16.598,,,
6077.80029,17.598,,,
6077.89209,17.598,,,
6077.98340,16.598,,,
6078.07520,17.598,,,
6078.16650,17.598,,,
6078.25781,16.598,,,
6078.34961,16.598,,,
6078.44092,17.598,,,
6078.53271,17.598,,,
6078.62402,17.598,,,
6078.71582,17.598,,,
6078.80713,17.598,,,
6078.89893,16.598,,,
6078.99023,17.598,,,
6079.08154,17.598,,,
6079.17334,17.598,,,
6079.26465,17.598,,,
6079.35645,18.598,,,
6079.44775,17.598,,,
6079.53955,17.598,,,
6079.63086,17.598,,,
6079.72217,17.598,,,
6079.81396,16.598,,,
6079.90527,17.598,,,
6079.99707,17.598,,,
6080.08838,17.598,,,
6080.18018,17.598,,,
6080.27148,17.598,,,
6080.36279,17.598,,,
6080.45459,17.598,,,
6080.54590,16.598,,,
6080.63770,17.598,,,
6080.72900,17.598,,,
6080.82080,17.598,,,
6080.91211,17.598,,,
6081.00342,17.598,,,
6081.09521,16.598,,,
6081.18652,17.598,,,
6081.27832,17.598,,,
6081.36963,17.598,,,
6081.46143,16.598,,,
6081.55273,17.598,,,
6081.64453,17.598,,,
6081.73584,16.598,,,
6081.82715,17.598,,,
6081.91895,16.598,,,
6082.01025,16.598,,,
6082.10205,17.598,,,
6082.19336,17.598,,,
6082.28516,17.598,,,
6082.37646,17.598,,,
6082.46777,16.598,,,
6082.55957,16.598,,,
6082.65088,17.598,,,
6082.74268,16.598,,,
6082.83398,16.598,,,
6082.92578,16.598,,,
6083.01709,16.598,,,
6083.10840,16.598,,,
6083.20020,16.598,,,
6083.29150,17.598,,,
6083.38330,16.598,,,
6083.47461,15.598,,,
6083.56641,16.598,,,
6083.65771,16.598,,,
6083.74951,17.598,,,
6083.84082,16.598,,,
6083.93213,16.598,,,
6084.02393,16.598,,,
6084.11523,17.598,,,
6084.20703,17.598,,,
6084.29834,17.598,,,
6084.39014,17.598,,,
6084.48145,17.598,,,
6084.57275,17.598,,,
6084.66455,17.598,,,
6084.75586,17.598,,,
6084.84766,17.598,,,
6084.93896,17.598,,,
6085.03076,17.598,,,
6085.12207,17.598,,,
6085.21338,17.598,,,
6085.30518,16.598,,,
6085.39648,17.598,,,
6085.48828,17.598,,,
6085.57959,17.598,,,
6085.67139,16.598,,,
6085.76270,17.598,,,
6085.85449,17.598,,,
6085.94580,18.598,,,
6086.03711,18.598,,,
6086.12891,18.598,,,
6086.22021,18.598,,,
6086.31201,18.598,,,
6086.40332,18.598,,,
6086.49512,18.598,,,
6086.58643,18.598,,,
6086.67773,18.598,,,
6086.76953,17.598,,,
6086.86084,17.598,,,
6086.95264,18.598,,,
6087.04395,18.598,,,
6087.13574,17.598,,,
6087.22705,17.598,,,
6087.31836,17.598,,,
6087.41016,17.598,,,
6087.50146,17.598,,,
6087.59326,16.598,,,
6087.68457,16.598,,,
6087.77637,16.598,,,
6087.86768,16.598,,,
6087.95947,17.598,,,
6088.05078,16.598,,,
6088.14209,17.598,,,
6088.23389,17.598,,,
6088.32520,17.598,,,
6088.41699,17.598,,,
6088.50830,17.598,,,
6088.60010,17.598,,,
6088.69141,17.598,,,
6088.78271,17.598,,,
6088.87451,17.598,,,
6088.96582,16.598,,,
6089.05762,16.598,,,
6089.14893,16.598,,,
6089.24072,16.598,,,
6089.33203,16.598,,,
6089.42334,16.598,,,
6089.51514,17.598,,,
6089.60645,17.598,,,
6089.69824,17.598,,,
6089.78955,16.598,,,
6089.88135,16.598,,,
6089.97266,16.598,,,
6090.06445,17.598,,,
6090.15576,16.598,,,
6090.24707,16.598,,,
6090.33887,16.598,,,
6090.43018,16.598,,,
6090.52197,16.598,,,
6090.61328,16.598,,,
6090.70508,16.598,,,
6090.79639,17.598,,,
6090.88770,16.598,,,
6090.97949,16.598,,,
6091.07080,17.598,,,
6091.16260,16.598,,,
6091.25391,17.598,,,
6091.34570,16.598,,,
6091.43701,16.598,,,
6091.52832,17.598,,,
6091.62012,17.598,,,
6091.71143,17.598,,,
6091.80322,16.598,,,
6091.89453,16.598,,,
6091.98633,16.598,,,
6092.07764,16.598,,,
6092.16895,17.598,,,
6092.26074,16.598,,,
6092.35205,16.598,,,
6092.44385,16.598,,,
6092.53516,17.598,,,
6092.62695,16.598,,,
6092.71826,17.598,,,
6092.81006,16.598,,,
6092.90137,16.598,,,
6092.99268,17.598,,,
6093.08447,17.598,,,
6093.17578,16.598,,,
6093.26758,16.598,,,
6093.35889,16.598,,,
6093.45068,17.598,,,
6093.54199,17.598,,,
6093.63330,16.598,,,
6093.72510,17.598,,,
6093.81641,16.598,,,
6093.90820,17.598,,,
6093.99951,17.598,,,
6094.09131,17.598,,,
6094.18262,17.598,,,
6094.27393,17.598,,,
6094.36572,17.598,,,
6094.45703,16.598,,,
6094.54883,16.598,,,
6094.64014,16.598,,,
6094.73193,17.598,,,
6094.82324,17.598,,,
6094.91504,16.598,,,
6095.00635,16.598,,,
6095.09766,16.598,,,
6095.18945,16.598,,,
6095.28076,17.598,,,
6095.37256,17.598,,,
6095.46387,16.598,,,
6095.55566,16.598,,,
6095.64697,16.598,,,
6095.73828,16.598,,,
6095.83008,16.598,,,
6095.92139,16.598,,,
6096.01318,16.598,,,
6096.10449,16.598,,,
6096.19629,17.598,,,
6096.28760,16.598,,,
6096.37891,16.598,,,
6096.47070,16.598,,,
6096.56201,16.598,,,
6096.65381,17.598,,,
6096.74512,16.598,,,
6096.83691,16.598,,,
6096.92822,17.598,,,
6097.02002,17.598,,,
6097.11133,17.598,,,
6097.20264,17.598,,,
6097.29443,17.598,,,
6097.38574,17.598,,,
6097.47754,17.598,,,
6097.56885,17.598,,,
6097.66064,17.598,,,
6097.75195,17.598,,,
6097.84326,17.598,,,
6097.93506,16.598,,,
6098.02637,17.598,,,
6098.11816,17.598,,,
6098.20947,16.598,,,
6098.30127,17.598,,,
6098.39258,17.598,,,
6098.48389,16.598,,,
6098.57568,16.598,,,
6098.66699,16.598,,,
6098.75879,16.598,,,
6098.85010,17.598,,,
6098.94189,17.598,,,
6099.03320,16.598,,,
6099.12500,16.598,,,
6099.21631,16.598,,,
6099.30762,16.598,,,
6099.39941,16.598,,,
6099.49072,17.598,,,
6099.58252,16.598,,,
6099.67383,16.598,,,
6099.76563,16.598,,,
6099.85693,17.598,,,
6099.94824,17.598,,,
6100.04004,17.598,,,
6100.13135,16.598,,,
6100.22314,17.598,,,
6100.31445,16.598,,,
6100.40625,17.598,,,
6100.49756,16.598,,,
6100.58887,17.598,,,
6100.68066,16.598,,,
6100.77197,17.598,,,
6100.86377,17.598,,,
6100.95508,16.598,,,
6101.04688,16.598,,,
6101.13818,17.598,,,
6101.22998,17.598,,,
6101.32129,17.598,,,
6101.41260,17.598,,,
6101.50439,17.598,,,
6101.59570,17.598,,,
6101.68750,16.598,,,
6101.77881,16.598,,,
6101.87061,17.598,,,
6101.96191,16.598,,,
6102.05322,17.598,,,
6102.14502,16.598,,,
6102.23633,16.598,,,
6102.32813,16.598,,,
6102.41943,16.598,,,
6102.51123,16.598,,,
6102.60254,16.598,,,
6102.69385,17.598,,,
6102.78564,17.598,,,
6102.87695,16.598,,,
6102.96875,17.598,,,
6103.06006,17.598,,,
6103.15186,16.598,,,
6103.24316,17.598,,,
6103.33496,16.598,,,
6103.42627,16.598,,,
6103.51758,16.598,,,
6103.60938,15.598,,,
6103.70068,16.598,,,
6103.79248,16.598,,,
6103.88379,16.598,,,
6103.97559,16.598,,,
6104.06689,16.598,,,
6104.15820,16.598,,,
6104.25000,17.598,,,
6104.34131,17.598,,,
6104.43311,17.598,,,
6104.52441,17.598,,,
6104.61621,17.598,,,
6104.70752,17.598,,,
6104.79883,17.598,,,
6104.89063,17.598,,,
6104.98193,17.598,,,
6105.07373,17.598,,,
6105.16504,17.598,,,
6105.25684,16.598,,,
6105.34814,17.598,,,
6105.43945,16.598,,,
6105.53125,16.598,,,
6105.62256,16.598,,,
6105.71436,16.598,,,
6105.80566,16.598,,,
6105.89746,16.598,,,
6105.98877,16.598,,,
6106.08057,16.598,,,
6106.17188,16.598,,,
6106.26318,16.598,,,
6106.35498,16.598,,,
6106.44629,16.598,,,
6106.53809,16.598,,,
6106.62939,17.598,,,
6106.72119,16.598,,,
6106.81250,16.598,,,
6106.90381,17.598,,,
6106.99561,16.598,,,
6107.08691,16.598,,,
6107.17871,16.598,,,
6107.27002,16.598,,,
6107.36182,16.598,,,
6107.45313,16.598,,,
6107.54443,16.598,,,
6107.63623,16.598,,,
6107.72754,16.598,,,
6107.81934,17.598,,,
6107.91064,16.598,,,
6108.00244,16.598,,,
6108.09375,16.598,,,
6108.18555,16.598,,,
6108.27686,16.598,,,
6108.36816,16.598,,,
6108.45996,16.598,,,
6108.55127,16.598,,,
6108.64307,17.598,,,
6108.73438,16.598,,,
6108.82617,16.598,,,
6108.91748,16.598,,,
6109.00879,16.598,,,
6109.10059,16.598,,,
6109.19189,16.598,,,
6109.28369,16.598,,,
6109.37500,16.598,,,
6109.46680,16.598,,,
6109.55811,16.598,,,
6109.64941,16.598,,,
6109.74121,16.598,,,
6109.83252,16.598,,,
6109.92432,16.598,,,
6110.01563,16.598,,,
6110.10742,16.598,,,
6110.19873,16.598,,,
6110.29053,17.598,,,
6110.38184,16.598,,,
6110.47314,16.598,,,
6110.56494,16.598,,,
6110.65625,16.598,,,
6110.74805,16.598,,,
6110.83936,16.598,,,
6110.93115,16.598,,,
6111.02246,16.598,,,
6111.11377,16.598,,,
6111.20557,16.598,,,
6111.29688,16.598,,,
6111.38867,16.598,,,
6111.47998,15.598,,,
6111.57178,17.598,,,
6111.66309,16.598,,,
6111.75439,16.598,,,
6111.84619,16.598,,,
6111.93750,16.598,,,
6112.02930,16.598,,,
6112.12061,16.598,,,
6112.21240,16.598,,,
6112.30371,16.598,,,
6112.39551,16.598,,,
6112.48682,16.598,,,
6112.57813,17.598,,,
6112.66992,16.598,,,
6112.76123,16.598,,,
6112.85303,16.598,,,
6112.94434,16.598,,,
6113.03613,17.598,,,
6113.12744,16.598,,,
6113.21875,16.598,,,
6113.31055,16.598,,,
6113.40186,17.598,,,
6113.49365,16.598,,,
6113.58496,16.598,,,
6113.67676,16.598,,,
6113.76807,17.598,,,
6113.85938,16.598,,,
6113.95117,16.598,,,
6114.04248,16.598,,,
6114.13428,16.598,,,
6114.22559,16.598,,,
6114.31738,16.598,,,
6114.40869,16.598,,,
6114.50049,17.598,,,
6114.59180,16.598,,,
6114.68311,16.598,,,
6114.77490,16.598,,,
6114.86621,16.598,,,
6114.95801,17.598,,,
6115.04932,16.598,,,
6115.14111,17.598,,,
6115.23242,17.598,,,
6115.32373,16.598,,,
6115.41553,16.598,,,
6115.50684,16.598,,,
6115.59863,16.598,,,
6115.68994,16.598,,,
6115.78174,16.598,,,
6115.87305,16.598,,,
6115.96436,17.598,,,
6116.05615,16.598,,,
6116.14746,16.598,,,
6116.23926,16.598,,,
6116.33057,17.598,,,
6116.42236,16.598,,,
6116.51367,16.598,,,
6116.60498,16.598,,,
6116.69678,16.598,,,
6116.78809,16.598,,,
6116.87988,16.598,,,
6116.97119,16.598,,,
6117.06299,16.598,,,
6117.15430,17.598,,,
6117.24609,15.598,,,
6117.33740,16.598,,,
6117.42871,17.598,,,
6117.52051,16.598,,,
6117.61182,16.598,,,
6117.70361,17.598,,,
6117.79492,16.598,,,
6117.88672,16.598,,,
6117.97803,16.598,,,
6118.06934,16.598,,,
6118.16113,16.598,,,
6118.25244,16.598,,,
6118.34424,16.598,,,
6118.43555,15.598,,,
6118.52734,16.598,,,
6118.61865,16.598,,,
6118.70996,15.598,,,
6118.80176,16.598,,,
6118.89307,16.598,,,
6118.98486,16.598,,,
6119.07617,16.598,,,
6119.16797,16.598,,,
6119.25928,16.598,,,
6119.35107,16.598,,,
6119.44238,16.598,,,
6119.53369,17.598,,,
6119.62549,16.598,,,
6119.71680,15.598,,,
6119.80859,16.598,,,
6119.89990,15.598,,,
6119.99170,15.598,,,
6120.08301,16.598,,,
6120.17432,16.598,,,
6120.26611,15.598,,,
6120.35742,16.598,,,
6120.44922,16.598,,,
6120.54053,16.598,,,
6120.63232,15.598,,,
6120.72363,15.598,,,
6120.81494,16.598,,,
6120.90674,16.598,,,
6120.99805,16.598,,,
6121.08984,16.598,,,
6121.18115,15.598,,,
6121.27295,16.598,,,
6121.36426,15.598,,,
6121.45605,16.598,,,
6121.54736,15.598,,,
6121.63867,16.598,,,
6121.73047,15.598,,,
6121.82178,15.598,,,
6121.91357,15.598,,,
6122.00488,15.598,,,
6122.09668,16.598,,,
6122.18799,16.598,,,
6122.27930,16.598,,,
6122.37109,16.598,,,
6122.46240,16.598,,,
6122.55420,17.598,,,
6122.64551,17.598,,,
6122.73730,16.598,,,
6122.82861,16.598,,,
6122.91992,16.598,,,
6123.01172,16.598,,,
6123.10303,16.598,,,
6123.19482,16.598,,,
6123.28613,16.598,,,
6123.37793,16.598,,,
6123.46924,17.598,,,
6123.56104,16.598,,,
6123.65234,16.598,,,
6123.74365,16.598,,,
6123.83545,16.598,,,
6123.92676,15.598,,,
6124.01855,15.598,,,
6124.10986,16.598,,,
6124.20166,16.598,,,
6124.29297,16.598,,,
6124.38428,16.598,,,
6124.47607,15.598,,,
6124.56738,15.598,,,
6124.65918,16.598,,,
6124.75049,17.598,,,
6124.84229,16.598,,,
6124.93359,16.598,,,
6125.02490,16.598,,,
6125.11670,16.598,,,
6125.20801,16.598,,,
6125.29980,16.598,,,
6125.39111,16.598,,,
6125.48291,16.598,,,
6125.57422,16.598,,,
6125.66602,16.598,,,
6125.75732,15.598,,,
6125.84863,15.598,,,
6125.94043,16.598,,,
6126.03174,15.598,,,
6126.12354,15.598,,,
6126.21484,16.598,,,
6126.30664,16.598,,,
6126.39795,16.598,,,
6126.48926,15.598,,,
6126.58105,15.598,,,
6126.67236,15.598,,,
6126.76416,15.598,,,
6126.85547,16.598,,,
6126.94727,16.598,,,
6127.03857,15.598,,,
6127.12988,15.598,,,
6127.22168,16.598,,,
6127.31299,15.598,,,
6127.40479,15.598,,,
6127.49609,16.598,,,
6127.58789,16.598,,,
6127.67920,16.598,,,
6127.77100,16.598,,,
6127.86230,15.598,,,
6127.95361,15.598,,,
6128.04541,16.598,,,
6128.13672,16.598,,,
6128.22852,15.598,,,
6128.31982,15.598,,,
6128.41162,16.598,,,
6128.50293,15.598,,,
6128.59424,16.598,,,
6128.68604,16.598,,,
6128.77734,15.598,,,
6128.86914,15.598,,,
6128.96045,15.598,,,
6129.05225,16.598,,,
6129.14355,16.598,,,
6129.23486,15.598,,,
6129.32666,16.598,,,
6129.41797,15.598,,,
6129.50977,15.598,,,
6129.60107,16.598,,,
6129.69287,16.598,,,
6129.78418,16.598,,,
6129.87549,16.598,,,
6129.96729,16.598,,,
6130.05859,15.598,,,
6130.15039,15.598,,,
6130.24170,16.598,,,
6130.33350,16.598,,,
6130.42480,15.598,,,
6130.51660,16.598,,,
6130.60791,16.598,,,
6130.69922,15.598,,,
6130.79102,16.598,,,
6130.88232,16.598,,,
6130.97412,15.598,,,
6131.06543,16.598,,,
6131.15723,16.598,,,
6131.24854,16.598,,,
6131.33984,16.598,,,
6131.43164,16.598,,,
6131.52295,16.598,,,
6131.61475,16.598,,,
6131.70605,15.598,,,
6131.79785,16.598,,,
6131.88916,15.598,,,
6131.98047,16.598,,,
6132.07227,16.598,,,
6132.16357,16.598,,,
6132.25537,16.598,,,
6132.34668,16.598,,,
6132.43848,15.598,,,
6132.52979,16.598,,,
6132.62158,16.598,,,
6132.71289,16.598,,,
6132.80420,16.598,,,
6132.89600,15.598,,,
6132.98730,16.598,,,
6133.07910,15.598,,,
6133.17041,16.598,,,
6133.26221,16.598,,,
6133.35352,16.598,,,
6133.44482,16.598,,,
6133.53662,16.598,,,
6133.62793,16.598,,,
6133.71973,16.598,,,
6133.81104,16.598,,,
6133.90283,15.598,,,
6133.99414,15.598,,,
6134.08545,16.598,,,
6134.17725,15.598,,,
6134.26855,16.598,,,
6134.36035,15.598,,,
6134.45166,15.598,,,
6134.54346,15.598,,,
6134.63477,16.598,,,
6134.72656,16.598,,,
6134.81787,16.598,,,
6134.90918,16.598,,,
6135.00098,16.598,,,
6135.09229,16.598,,,
6135.18408,16.598,,,
6135.27539,15.598,,,
6135.36719,15.598,,,
6135.45850,16.598,,,
6135.54980,15.598,,,
6135.64160,15.598,,,
6135.73291,15.598,,,
6135.82471,15.598,,,
6135.91602,15.598,,,
6136.00781,15.598,,,
6136.09912,15.598,,,
6136.19043,15.598,,,
6136.28223,15.598,,,
6136.37354,15.598,,,
6136.46533,15.598,,,
6136.55664,15.598,,,
6136.64844,15.598,,,
6136.73975,16.598,,,
6136.83154,15.598,,,
6136.92285,15.598,,,
6137.01416,15.598,,,
6137.10596,15.598,,,
6137.19727,15.598,,,
6137.28906,15.598,,,
6137.38037,15.598,,,
6137.47217,15.598,,,
6137.56348,15.598,,,
6137.65479,15.598,,,
6137.74658,15.598,,,
6137.83789,15.598,,,
6137.92969,15.598,,,
6138.02100,15.598,,,
6138.11279,15.598,,,
6138.20410,15.598,,,
6138.29541,15.598,,,
6138.38721,15.598,,,
6138.47852,15.598,,,
6138.57031,16.598,,,
6138.66162,16.598,,,
6138.75342,15.598,,,
6138.84473,15.598,,,
6138.93652,15.598,,,
6139.02783,15.598,,,
6139.11914,15.598,,,
6139.21094,15.598,,,
6139.30225,15.598,,,
6139.39404,15.598,,,
6139.48535,15.598,,,
6139.57715,15.598,,,
6139.66846,15.598,,,
6139.75977,15.598,,,
6139.85156,15.598,,,
6139.94287,15.598,,,
6140.03467,15.598,,,
6140.12598,16.598,,,
6140.21777,15.598,,,
6140.30908,16.598,,,
6140.40039,16.598,,,
6140.49219,15.598,,,
6140.58350,15.598,,,
6140.67529,15.598,,,
6140.76660,15.598,,,
6140.85840,15.598,,,
6140.94971,15.598,,,
6141.04150,15.598,,,
6141.13281,15.598,,,
6141.22412,15.598,,,
6141.31592,15.598,,,
6141.40723,15.598,,,
6141.49902,15.598,,,
6141.59033,15.598,,,
6141.68213,15.598,,,
6141.77344,14.598,,,
6141.86475,15.598,,,
6141.95654,15.598,,,
6142.04785,15.598,,,
6142.13965,15.598,,,
6142.23096,15.598,,,
6142.32275,15.598,,,
6142.41406,15.598,,,
6142.50537,15.598,,,
6142.59717,15.598,,,
6142.68848,15.598,,,
6142.78027,15.598,,,
6142.87158,15.598,,,
6142.96338,15.598,,,
6143.05469,14.598,,,
6143.14600,15.598,,,
6143.23779,15.598,,,
6143.32910,15.598,,,
6143.42090,15.598,,,
6143.51221,15.598,,,
6143.60400,15.598,,,
6143.69531,15.598,,,
6143.78711,15.598,,,
6143.87842,14.598,,,
6143.96973,15.598,,,
6144.06152,15.598,,,
6144.15283,14.598,,,
6144.24463,15.598,,,
6144.33594,15.598,,,
6144.42773,15.598,,,
6144.51904,15.598,,,
6144.61035,15.598,,,
6144.70215,15.598,,,
6144.79346,15.598,,,
6144.88525,15.598,,,
6144.97656,15.598,,,
6145.06836,15.598,,,
6145.15967,15.598,,,
6145.25098,15.598,,,
6145.34277,15.598,,,
6145.43408,14.598,,,
6145.52588,15.598,,,
6145.61719,15.598,,,
6145.70898,15.598,,,
6145.80029,15.598,,,
6145.89209,15.598,,,
6145.98340,15.598,,,
6146.07471,15.598,,,
6146.16650,15.598,,,
6146.25781,15.598,,,
6146.34961,15.598,,,
6146.44092,15.598,,,
6146.53271,15.598,,,
6146.62402,15.598,,,
6146.71533,15.598,,,
6146.80713,15.598,,,
6146.89844,15.598,,,
6146.99023,15.598,,,
6147.08154,14.598,,,
6147.17334,14.598,,,
6147.26465,15.598,,,
6147.35596,15.598,,,
6147.44775,15.598,,,
6147.53906,15.598,,,
6147.63086,14.598,,,
6147.72217,15.598,,,
6147.81396,15.598,,,
6147.90527,15.598,,,
6147.99707,15.598,,,
6148.08838,15.598,,,
6148.17969,15.598,,,
6148.27148,15.598,,,
6148.36279,15.598,,,
6148.45459,15.598,,,
6148.54590,15.598,,,
6148.63770,15.598,,,
6148.72900,14.598,,,
6148.82031,14.598,,,
6148.91211,14.598,,,
6149.00342,14.598,,,
6149.09521,14.598,,,
6149.18652,15.598,,,
6149.27832,14.598,,,
6149.36963,14.598,,,
6149.46094,14.598,,,
6149.55273,15.598,,,
6149.64404,15.598,,,
6149.73584,14.598,,,
6149.82715,15.598,,,
6149.91895,14.598,,,
6150.01025,14.598,,,
6150.10205,15.598,,,
6150.19336,15.598,,,
6150.28467,15.598,,,
6150.37646,15.598,,,
6150.46777,15.598,,,
6150.55957,14.598,,,
6150.65088,14.598,,,
6150.74268,14.598,,,
6150.83398,15.598,,,
6150.92529,14.598,,,
6151.01709,14.598,,,
6151.10840,15.598,,,
6151.20020,14.598,,,
6151.29150,14.598,,,
6151.38330,14.598,,,
6151.47461,15.598,,,
6151.56592,14.598,,,
6151.65771,15.598,,,
6151.74902,15.598,,,
6151.84082,15.598,,,
6151.93213,14.598,,,
6152.02393,14.598,,,
6152.11523,14.598,,,
6152.20703,15.598,,,
6152.29834,14.598,,,
6152.38965,14.598,,,
6152.48145,15.598,,,
6152.57275,15.598,,,
6152.66455,15.598,,,
6152.75586,15.598,,,
6152.84766,15.598,,,
6152.93896,15.598,,,
6153.03027,15.598,,,
6153.12207,14.598,,,
6153.21338,15.598,,,
6153.30518,15.598,,,
6153.39648,14.598,,,
6153.48828,14.598,,,
6153.57959,14.598,,,
6153.67090,14.598,,,
6153.76270,14.598,,,
6153.85400,15.598,,,
6153.94580,14.598,,,
6154.03711,15.598,,,
6154.12891,15.598,,,
6154.22021,14.598,,,
6154.31152,14.598,,,
6154.40332,14.598,,,
6154.49463,15.598,,,
6154.58643,15.598,,,
6154.67773,15.598,,,
6154.76953,15.598,,,
6154.86084,15.598,,,
6154.95264,14.598,,,
6155.04395,14.598,,,
6155.13525,14.598,,,
6155.22705,14.598,,,
6155.31836,14.598,,,
6155.41016,15.598,,,
6155.50146,15.598,,,
6155.59326,15.598,,,
6155.68457,14.598,,,
6155.77588,15.598,,,
6155.86768,14.598,,,
6155.95898,15.598,,,
6156.05078,15.598,,,
6156.14209,14.598,,,
6156.23389,14.598,,,
6156.32520,14.598,,,
6156.41650,14.598,,,
6156.50830,14.598,,,
6156.59961,15.598,,,
6156.69141,15.598,,,
6156.78271,14.598,,,
6156.87451,14.598,,,
6156.96582,15.598,,,
6157.05762,14.598,,,
6157.14893,15.598,,,
6157.24023,14.598,,,
6157.33203,14.598,,,
6157.42334,15.598,,,
6157.51514,15.598,,,
6157.60645,15.598,,,
6157.69824,14.598,,,
6157.78955,15.598,,,
6157.88086,14.598,,,
6157.97266,14.598,,,
6158.06396,14.598,,,
6158.15576,15.598,,,
6158.24707,14.598,,,
6158.33887,15.598,,,
6158.43018,15.598,,,
6158.52148,14.598,,,
6158.61328,14.598,,,
6158.70459,14.598,,,
6158.79639,14.598,,,
6158.88770,14.598,,,
6158.97949,15.598,,,
6159.07080,15.598,,,
6159.16260,14.598,,,
6159.25391,14.598,,,
6159.34521,14.598,,,
6159.43701,14.598,,,
6159.52832,14.598,,,
6159.62012,14.598,,,
6159.71143,14.598,,,
6159.80322,14.598,,,
6159.89453,15.598,,,
6159.98584,15.598,,,
6160.07764,14.598,,,
6160.16895,14.598,,,
6160.26074,14.598,,,
6160.35205,14.598,,,
6160.44385,15.598,,,
6160.53516,15.598,,,
6160.62646,14.598,,,
6160.71826,14.598,,,
6160.80957,14.598,,,
6160.90137,14.598,,,
6160.99268,14.598,,,
6161.08447,14.598,,,
6161.17578,14.598,,,
6161.26758,15.598,,,
6161.35889,15.598,,,
6161.45020,14.598,,,
6161.54199,15.598,,,
6161.63330,15.598,,,
6161.72510,14.598,,,
6161.81641,15.598,,,
6161.90820,15.598,,,
6161.99951,15.598,,,
6162.09082,15.598,,,
6162.18262,15.598,,,
6162.27393,15.598,,,
6162.36572,14.598,,,
6162.45703,14.598,,,
6162.54883,15.598,,,
6162.64014,14.598,,,
6162.73145,15.598,,,
6162.82324,15.598,,,
6162.91455,15.598,,,
6163.00635,15.598,,,
6163.09766,14.598,,,
6163.18945,14.598,,,
6163.28076,14.598,,,
6163.37256,15.598,,,
6163.46387,14.598,,,
6163.55518,14.598,,,
6163.64697,14.598,,,
6163.73828,14.598,,,
6163.83008,14.598,,,
6163.92139,14.598,,,
6164.01318,14.598,,,
6164.10449,14.598,,,
6164.19580,15.598,,,
6164.28760,15.598,,,
6164.37891,14.598,,,
6164.47070,14.598,,,
6164.56201,14.598,,,
6164.65381,14.598,,,
6164.74512,14.598,,,
6164.83643,15.598,,,
6164.92822,14.598,,,
6165.01953,14.598,,,
6165.11133,14.598,,,
6165.20264,14.598,,,
6165.29443,14.598,,,
6165.38574,14.598,,,
6165.47754,14.598,,,
6165.56885,14.598,,,
6165.66016,14.598,,,
6165.75195,15.598,,,
6165.84326,14.598,,,
6165.93506,15.598,,,
6166.02637,14.598,,,
6166.11816,14.598,,,
6166.20947,14.598,,,
6166.30078,14.598,,,
6166.39258,15.598,,,
6166.48389,14.598,,,
6166.57568,14.598,,,
6166.66699,14.598,,,
6166.75879,14.598,,,
6166.85010,14.598,,,
6166.94141,14.598,,,
6167.03320,14.598,,,
6167.12451,14.598,,,
6167.21631,15.598,,,
6167.30762,14.598,,,
6167.39941,15.598,,,
6167.49072,14.598,,,
6167.58203,14.598,,,
6167.67383,15.598,,,
6167.76514,14.598,,,
6167.85693,14.598,,,
6167.94824,14.598,,,
6168.04004,14.598,,,
6168.13135,14.598,,,
6168.22314,14.598,,,
6168.31445,14.598,,,
6168.40576,14.598,,,
6168.49756,14.598,,,
6168.58887,14.598,,,
6168.68066,15.598,,,
6168.77197,14.598,,,
6168.86377,14.598,,,
6168.95508,14.598,,,
6169.04639,14.598,,,
6169.13818,14.598,,,
6169.22949,15.598,,,
6169.32129,14.598,,,
6169.41260,14.598,,,
6169.50439,14.598,,,
6169.59570,14.598,,,
6169.68701,14.598,,,
6169.77881,14.598,,,
6169.87012,14.598,,,
6169.96191,14.598,,,
6170.05322,14.598,,,
6170.14502,15.598,,,
6170.23633,14.598,,,
6170.32813,14.598,,,
6170.41943,15.598,,,
6170.51074,14.598,,,
6170.60254,14.598,,,
6170.69385,14.598,,,
6170.78564,15.598,,,
6170.87695,13.598,,,
6170.96875,14.598,,,
6171.06006,14.598,,,
6171.15137,14.598,,,
6171.24316,14.598,,,
6171.33447,14.598,,,
6171.42627,14.598,,,
6171.51758,14.598,,,
6171.60938,14.598,,,
6171.70068,14.598,,,
6171.79199,14.598,,,
6171.88379,14.598,,,
6171.97510,14.598,,,
6172.06689,14.598,,,
6172.15820,14.598,,,
6172.25000,15.598,,,
6172.34131,14.598,,,
6172.43311,14.598,,,
6172.52441,14.598,,,
6172.61572,14.598,,,
6172.70752,14.598,,,
6172.79883,14.598,,,
6172.89063,14.598,,,
6172.98193,14.598,,,
6173.07373,15.598,,,
6173.16504,15.598,,,
6173.25635,14.598,,,
6173.34814,14.598,,,
6173.43945,14.598,,,
6173.53125,15.598,,,
6173.62256,15.598,,,
6173.71436,14.598,,,
6173.80566,14.598,,,
6173.89697,14.598,,,
6173.98877,14.598,,,
6174.08008,14.598,,,
6174.17188,15.598,,,
6174.26318,14.598,,,
6174.35498,14.598,,,
6174.44629,15.598,,,
6174.53809,14.598,,,
6174.62939,14.598,,,
6174.72070,14.598,,,
6174.81250,15.598,,,
6174.90381,14.598,,,
6174.99561,14.598,,,
6175.08691,15.598,,,
6175.17871,14.598,,,
6175.27002,15.598,,,
6175.36133,14.598,,,
6175.45313,14.598,,,
6175.54443,14.598,,,
6175.63623,14.598,,,
6175.72754,14.598,,,
6175.81934,14.598,,,
6175.91064,14.598,,,
6176.00195,14.598,,,
6176.09375,14.598,,,
6176.18506,14.598,,,
6176.27686,14.598,,,
6176.36816,14.598,,,
6176.45996,14.598,,,
6176.55127,14.598,,,
6176.64307,14.598,,,
6176.73438,14.598,,,
6176.82568,13.598,,,
6176.91748,14.598,,,
6177.00879,14.598,,,
6177.10059,14.598,,,
6177.19189,14.598,,,
6177.28369,15.598,,,
6177.37500,15.598,,,
6177.46631,16.598,,,
6177.55811,15.598,,,
6177.64941,15.598,,,
6177.74121,15.598,,,
6177.83252,15.598,,,
6177.92432,14.598,,,
6178.01563,15.598,,,
6178.10693,15.598,,,
6178.19873,14.598,,,
6178.29004,14.598,,,
6178.38184,14.598,,,
6178.47314,14.598,,,
6178.56494,14.598,,,
6178.65625,14.598,,,
6178.74756,14.598,,,
6178.83936,14.598,,,
6178.93066,14.598,,,
6179.02246,14.598,,,
6179.11377,14.598,,,
6179.20557,14.598,,,
6179.29688,14.598,,,
6179.38867,14.598,,,
6179.47998,14.598,,,
6179.57129,14.598,,,
6179.66309,14.598,,,
6179.75439,13.598,,,
6179.84619,14.598,,,
6179.93750,14.598,,,
6180.02930,14.598,,,
6180.12061,14.598,,,
6180.21191,14.598,,,
6180.30371,14.598,,,
6180.39502,14.598,,,
6180.48682,15.598,,,
6180.57813,14.598,,,
6180.66992,13.598,,,
6180.76123,14.598,,,
6180.85254,14.598,,,
6180.94434,14.598,,,
6181.03564,14.598,,,
6181.12744,15.598,,,
6181.21875,14.598,,,
6181.31055,14.598,,,
6181.40186,14.598,,,
6181.49365,14.598,,,
6181.58496,14.598,,,
6181.67627,14.598,,,
6181.76807,14.598,,,
6181.85938,15.598,,,
6181.95117,14.598,,,
6182.04248,14.598,,,
6182.13428,15.598,,,
6182.22559,14.598,,,
6182.31689,14.598,,,
6182.40869,15.598,,,
6182.50000,14.598,,,
6182.59180,15.598,,,
6182.68311,15.598,,,
6182.77490,14.598,,,
6182.86621,14.598,,,
6182.95752,14.598,,,
6183.04932,14.598,,,
6183.14063,14.598,,,
6183.23242,14.598,,,
6183.32373,15.598,,,
6183.41553,14.598,,,
6183.50684,14.598,,,
6183.59863,15.598,,,
6183.68994,14.598,,,
6183.78125,14.598,,,
6183.87305,15.598,,,
6183.96436,14.598,,,
6184.05615,14.598,,,
6184.14746,14.598,,,
6184.23926,14.598,,,
6184.33057,14.598,,,
6184.42188,13.598,,,
6184.51367,14.598,,,
6184.60498,14.598,,,
6184.69678,14.598,,,
6184.78809,15.598,,,
6184.87988,14.598,,,
6184.97119,14.598,,,
6185.06250,14.598,,,
6185.15430,14.598,,,
6185.24561,13.598,,,
6185.33740,14.598,,,
6185.42871,14.598,,,
6185.52051,14.598,,,
6185.61182,14.598,,,
6185.70361,14.598,,,
6185.79492,14.598,,,
6185.88623,14.598,,,
6185.97803,14.598,,,
6186.06934,14.598,,,
6186.16113,14.598,,,
6186.25244,15.598,,,
6186.34424,14.598,,,
6186.43555,14.598,,,
6186.52686,13.598,,,
6186.61865,14.598,,,
6186.70996,14.598,,,
6186.80176,14.598,,,
6186.89307,14.598,,,
6186.98486,14.598,,,
6187.07617,14.598,,,
6187.16748,14.598,,,
6187.25928,14.598,,,
6187.35059,14.598,,,
6187.44238,14.598,,,
6187.53369,14.598,,,
6187.62549,14.598,,,
6187.71680,14.598,,,
6187.80859,14.598,,,
6187.89990,14.598,,,
6187.99121,14.598,,,
6188.08301,14.598,,,
6188.17432,14.598,,,
6188.26611,14.598,,,
6188.35742,14.598,,,
6188.44922,15.598,,,
6188.54053,14.598,,,
6188.63184,14.598,,,
6188.72363,14.598,,,
6188.81494,14.598,,,
6188.90674,14.598,,,
6188.99805,14.598,,,
6189.08984,14.598,,,
6189.18115,15.598,,,
6189.27246,14.598,,,
6189.36426,14.598,,,
6189.45557,14.598,,,
6189.54736,14.598,,,
6189.63867,14.598,,,
6189.73047,14.598,,,
6189.82178,14.598,,,
6189.91357,14.598,,,
6190.00488,14.598,,,
6190.09619,13.598,,,
6190.18799,14.598,,,
6190.27930,13.598,,,
6190.37109,14.598,,,
6190.46240,14.598,,,
6190.55420,13.598,,,
6190.64551,15.598,,,
6190.73682,14.598,,,
6190.82861,14.598,,,
6190.91992,14.598,,,
6191.01172,14.598,,,
6191.10303,14.598,,,
6191.19482,14.598,,,
6191.28613,14.598,,,
6191.37744,14.598,,,
6191.46924,14.598,,,
6191.56055,14.598,,,
6191.65234,14.598,,,
6191.74365,14.598,,,
6191.83545,14.598,,,
6191.92676,13.598,,,
6192.01807,14.598,,,
6192.10986,13.598,,,
6192.20117,14.598,,,
6192.29297,14.598,,,
6192.38428,14.598,,,
6192.47607,14.598,,,
6192.56738,14.598,,,
6192.65918,14.598,,,
6192.75049,14.598,,,
6192.84180,14.598,,,
6192.93359,14.598,,,
6193.02490,14.598,,,
6193.11670,15.598,,,
6193.20801,14.598,,,
6193.29980,14.598,,,
6193.39111,14.598,,,
6193.48242,14.598,,,
6193.57422,14.598,,,
6193.66553,14.598,,,
6193.75732,14.598,,,
6193.84863,14.598,,,
6193.94043,14.598,,,
6194.03174,14.598,,,
6194.12305,14.598,,,
6194.21484,14.598,,,
6194.30615,14.598,,,
6194.39795,14.598,,,
6194.48926,13.598,,,
6194.58105,14.598,,,
6194.67236,14.598,,,
6194.76416,14.598,,,
6194.85547,13.598,,,
6194.94678,14.598,,,
6195.03857,14.598,,,
6195.12988,14.598,,,
6195.22168,15.598,,,
6195.31299,15.598,,,
6195.40479,14.598,,,
6195.49609,14.598,,,
6195.58740,13.598,,,
6195.67920,13.598,,,
6195.77051,13.598,,,
6195.86230,13.598,,,
6195.95361,13.598,,,
6196.04541,13.598,,,
6196.13672,13.598,,,
6196.22803,13.598,,,
6196.31982,13.598,,,
6196.41113,13.598,,,
6196.50293,14.598,,,
6196.59424,13.598,,,
6196.68604,13.598,,,
6196.77734,13.598,,,
6196.86914,13.598,,,
6196.96045,13.598,,,
6197.05176,13.598,,,
6197.14355,13.598,,,
6197.23486,13.598,,,
6197.32666,13.598,,,
6197.41797,14.598,,,
6197.50977,13.598,,,
6197.60107,13.598,,,
6197.69238,14.598,,,
6197.78418,13.598,,,
6197.87549,13.598,,,
6197.96729,14.598,,,
6198.05859,13.598,,,
6198.15039,13.598,,,
6198.24170,13.598,,,
6198.33301,13.598,,,
6198.42480,13.598,,,
6198.51611,13.598,,,
6198.60791,14.598,,,
6198.69922,14.598,,,
6198.79102,13.598,,,
6198.88232,13.598,,,
6198.97412,13.598,,,
6199.06543,13.598,,,
6199.15674,13.598,,,
6199.24854,14.598,,,
6199.33984,14.598,,,
6199.43164,14.598,,,
6199.52295,14.598,,,
6199.61475,13.598,,,
6199.70605,13.598,,,
6199.79736,13.598,,,
6199.88916,13.598,,,
6199.98047,13.598,,,
6200.07227,13.598,,,
6200.16357,13.598,,,
6200.25537,13.598,,,
6200.34668,13.598,,,
6200.43799,13.598,,,
6200.52979,13.598,,,
6200.62109,13.598,,,
6200.71289,13.598,,,
6200.80420,13.598,,,
6200.89600,13.598,,,
6200.98730,13.598,,,
6201.07910,13.598,,,
6201.17041,13.598,,,
6201.26172,13.598,,,
6201.35352,13.598,,,
6201.44482,13.598,,,
6201.53662,13.598,,,
6201.62793,13.598,,,
6201.71973,13.598,,,
6201.81104,13.598,,,
6201.90234,13.598,,,
6201.99414,14.598,,,
6202.08545,13.598,,,
6202.17725,13.598,,,
6202.26855,13.598,,,
6202.36035,14.598,,,
6202.45166,14.598,,,
6202.54297,14.598,,,
6202.63477,14.598,,,
6202.72607,13.598,,,
6202.81787,13.598,,,
6202.90918,14.598,,,
6203.00098,14.598,,,
6203.09229,13.598,,,
6203.18408,13.598,,,
6203.27539,14.598,,,
6203.36670,13.598,,,
6203.45850,13.598,,,
6203.54980,13.598,,,
6203.64160,13.598,,,
6203.73291,13.598,,,
6203.82471,14.598,,,
6203.91602,13.598,,,
6204.00732,13.598,,,
6204.09912,13.598,,,
6204.19043,13.598,,,
6204.28223,13.598,,,
6204.37354,13.598,,,
6204.46533,13.598,,,
6204.55664,13.598,,,
6204.64795,13.598,,,
6204.73975,13.598,,,
6204.83105,13.598,,,
6204.92285,13.598,,,
6205.01416,13.598,,,
6205.10596,13.598,,,
6205.19727,13.598,,,
6205.28857,14.598,,,
6205.38037,13.598,,,
6205.47168,13.598,,,
6205.56348,13.598,,,
6205.65479,13.598,,,
6205.74658,13.598,,,
6205.83789,13.598,,,
6205.92969,13.598,,,
6206.02100,14.598,,,
6206.11230,13.598,,,
6206.20410,13.598,,,
6206.29541,13.598,,,
6206.38721,13.598,,,
6206.47852,13.598,,,
6206.57031,13.598,,,
6206.66162,13.598,,,
6206.75293,14.598,,,
6206.84473,13.598,,,
6206.93604,13.598,,,
6207.02783,13.598,,,
6207.11914,13.598,,,
6207.21094,13.598,,,
6207.30225,13.598,,,
6207.39355,13.598,,,
6207.48535,13.598,,,
6207.57666,13.598,,,
6207.66846,13.598,,,
6207.75977,13.598,,,
6207.85156,13.598,,,
6207.94287,13.598,,,
6208.03467,13.598,,,
6208.12598,13.598,,,
6208.21729,13.598,,,
6208.30908,13.598,,,
6208.40039,13.598,,,
6208.49219,13.598,,,
6208.58350,13.598,,,
6208.67529,13.598,,,
6208.76660,12.598,,,
6208.85791,13.598,,,
6208.94971,13.598,,,
6209.04102,13.598,,,
6209.13281,13.598,,,
6209.22412,13.598,,,
6209.31592,13.598,,,
6209.40723,13.598,,,
6209.49854,13.598,,,
6209.59033,13.598,,,
6209.68164,13.598,,,
6209.77344,13.598,,,
6209.86475,13.598,,,
6209.95654,13.598,,,
6210.04785,13.598,,,
6210.13965,13.598,,,
6210.23096,13.598,,,
6210.32227,13.598,,,
6210.41406,13.598,,,
6210.50537,13.598,,,
6210.59717,13.598,,,
6210.68848,14.598,,,
6210.78027,13.598,,,
6210.87158,13.598,,,
6210.96289,13.598,,,
6211.05469,13.598,,,
6211.14600,14.598,,,
6211.23779,13.598,,,
6211.32910,14.598,,,
6211.42090,14.598,,,
6211.51221,14.598,,,
6211.60352,14.598,,,
6211.69531,14.598,,,
6211.78662,15.598,,,
6211.87842,14.598,,,
6211.96973,14.598,,,
6212.06152,14.598,,,
6212.15283,13.598,,,
6212.24463,13.598,,,
6212.33594,13.598,,,
6212.42725,14.598,,,
6212.51904,13.598,,,
6212.61035,13.598,,,
6212.70215,13.598,,,
6212.79346,13.598,,,
6212.88525,13.598,,,
6212.97656,14.598,,,
6213.06787,14.598,,,
6213.15967,13.598,,,
6213.25098,13.598,,,
6213.34277,14.598,,,
6213.43408,14.598,,,
6213.52588,13.598,,,
6213.61719,14.598,,,
6213.70850,14.598,,,
6213.80029,14.598,,,
6213.89160,14.598,,,
6213.98340,14.598,,,
6214.07471,14.598,,,
6214.16650,13.598,,,
6214.25781,14.598,,,
6214.34961,13.598,,,
6214.44092,13.598,,,
6214.53223,13.598,,,
6214.62402,13.598,,,
6214.71533,13.598,,,
6214.80713,13.598,,,
6214.89844,13.598,,,
6214.99023,13.598,,,
6215.08154,13.598,,,
6215.17285,13.598,,,
6215.26465,13.598,,,
6215.35596,13.598,,,
6215.44775,13.598,,,
6215.53906,13.598,,,
6215.63086,13.598,,,
6215.72217,13.598,,,
6215.81348,14.598,,,
6215.90527,13.598,,,
6215.99658,13.598,,,
6216.08838,14.598,,,
6216.17969,14.598,,,
6216.27148,13.598,,,
6216.36279,13.598,,,
6216.45410,13.598,,,
6216.54590,13.598,,,
6216.63721,13.598,,,
6216.72900,13.598,,,
6216.82031,13.598,,,
6216.91211,13.598,,,
6217.00342,13.598,,,
6217.09521,13.598,,,
6217.18652,13.598,,,
6217.27783,13.598,,,
6217.36963,13.598,,,
6217.46094,13.598,,,
6217.55273,13.598,,,
6217.64404,13.598,,,
6217.73584,13.598,,,
6217.82715,13.598,,,
6217.91846,13.598,,,
6218.01025,13.598,,,
6218.10156,13.598,,,
6218.19336,13.598,,,
6218.28467,13.598,,,
6218.37646,13.598,,,
6218.46777,14.598,,,
6218.55908,13.598,,,
6218.65088,14.598,,,
6218.74219,13.598,,,
6218.83398,13.598,,,
6218.92529,13.598,,,
6219.01709,13.598,,,
6219.10840,13.598,,,
6219.20020,13.598,,,
6219.29150,12.598,,,
6219.38281,13.598,,,
6219.47461,13.598,,,
6219.56592,13.598,,,
6219.65771,12.598,,,
6219.74902,13.598,,,
6219.84082,14.598,,,
6219.93213,13.598,,,
6220.02344,13.598,,,
6220.11523,13.598,,,
6220.20654,13.598,,,
6220.29834,13.598,,,
6220.38965,13.598,,,
6220.48145,13.598,,,
6220.57275,13.598,,,
6220.66406,13.598,,,
6220.75586,13.598,,,
6220.84717,12.598,,,
6220.93896,13.598,,,
6221.03027,13.598,,,
6221.12207,12.598,,,
6221.21338,12.598,,,
6221.30518,12.598,,,
6221.39648,13.598,,,
6221.48779,13.598,,,
6221.57959,13.598,,,
6221.67090,13.598,,,
6221.76270,13.598,,,
6221.85400,13.598,,,
6221.94580,13.598,,,
6222.03711,13.598,,,
6222.12842,13.598,,,
6222.22021,13.598,,,
6222.31152,13.598,,,
6222.40332,13.598,,,
6222.49463,13.598,,,
6222.58643,13.598,,,
6222.67773,13.598,,,
6222.76904,13.598,,,
6222.86084,13.598,,,
6222.95215,13.598,,,
6223.04395,13.598,,,
6223.13525,13.598,,,
6223.22705,13.598,,,
6223.31836,13.598,,,
6223.41016,13.598,,,
6223.50146,13.598,,,
6223.59277,13.598,,,
6223.68457,13.598,,,
6223.77588,13.598,,,
6223.86768,13.598,,,
6223.95898,13.598,,,
6224.05078,13.598,,,
6224.14209,13.598,,,
6224.23340,13.598,,,
6224.32520,14.598,,,
6224.41650,13.598,,,
6224.50830,13.598,,,
6224.59961,13.598,,,
6224.69141,13.598,,,
6224.78271,13.598,,,
6224.87402,13.598,,,
6224.96582,13.598,,,
6225.05713,13.598,,,
6225.14893,12.598,,,
6225.24023,13.598,,,
6225.33203,13.598,,,
6225.42334,13.598,,,
6225.51514,13.598,,,
6225.60645,13.598,,,
6225.69775,14.598,,,
6225.78955,14.598,,,
6225.88086,13.598,,,
6225.97266,13.598,,,
6226.06396,13.598,,,
6226.15576,13.598,,,
6226.24707,13.598,,,
6226.33838,13.598,,,
6226.43018,13.598,,,
6226.52148,13.598,,,
6226.61328,14.598,,,
6226.70459,13.598,,,
6226.79639,13.598,,,
6226.88770,13.598,,,
6226.97900,13.598,,,
6227.07080,13.598,,,
6227.16211,13.598,,,
6227.25391,13.598,,,
6227.34521,13.598,,,
6227.43701,14.598,,,
6227.52832,13.598,,,
6227.62012,13.598,,,
6227.71143,14.598,,,
6227.80273,13.598,,,
6227.89453,13.598,,,
6227.98584,13.598,,,
6228.07764,14.598,,,
6228.16895,13.598,,,
6228.26074,13.598,,,
6228.35205,13.598,,,
6228.44336,13.598,,,
6228.53516,13.598,,,
6228.62646,13.598,,,
6228.71826,14.598,,,
6228.80957,13.598,,,
6228.90137,13.598,,,
6228.99268,13.598,,,
6229.08398,13.598,,,
6229.17578,13.598,,,
6229.26709,13.598,,,
6229.35889,13.598,,,
6229.45020,13.598,,,
6229.54199,13.598,,,
6229.63330,12.598,,,
6229.72461,13.598,,,
6229.81641,13.598,,,
6229.90771,13.598,,,
6229.99951,12.598,,,
6230.09082,12.598,,,
6230.18262,13.598,,,
6230.27393,12.598,,,
6230.36572,12.598,,,
6230.45703,12.598,,,
6230.54834,12.598,,,
6230.64014,12.598,,,
6230.73145,12.598,,,
6230.82324,12.598,,,
6230.91455,12.598,,,
6231.00635,12.598,,,
6231.09766,12.598,,,
6231.18896,13.598,,,
6231.28076,12.598,,,
6231.37207,13.598,,,
6231.46387,12.598,,,
6231.55518,13.598,,,
6231.64697,14.598,,,
6231.73828,13.598,,,
6231.82959,13.598,,,
6231.92139,13.598,,,
6232.01270,13.598,,,
6232.10449,13.598,,,
6232.19580,13.598,,,
6232.28760,13.598,,,
6232.37891,13.598,,,
6232.47070,13.598,,,
6232.56201,12.598,,,
6232.65332,12.598,,,
6232.74512,12.598,,,
6232.83643,11.598,,,
6232.92822,11.598,,,
6233.01953,11.598,,,
6233.11133,12.598,,,
6233.20264,11.598,,,
6233.29395,12.598,,,
6233.38574,12.598,,,
6233.47705,12.598,,,
6233.56885,12.598,,,
6233.66016,13.598,,,
6233.75195,12.598,,,
6233.84326,12.598,,,
6233.93457,13.598,,,
6234.02637,12.598,,,
6234.11768,12.598,,,
6234.20947,13.598,,,
6234.30078,12.598,,,
6234.39258,13.598,,,
6234.48389,12.598,,,
6234.57568,13.598,,,
6234.66699,13.598,,,
6234.75830,12.598,,,
6234.85010,13.598,,,
6234.94141,13.598,,,
6235.03320,13.598,,,
6235.12451,13.598,,,
6235.21631,13.598,,,
6235.30762,13.598,,,
6235.39893,13.598,,,
6235.49072,13.598,,,
6235.58203,13.598,,,
6235.67383,13.598,,,
6235.76514,13.598,,,
6235.85693,13.598,,,
6235.94824,13.598,,,
6236.03955,14.598,,,
6236.13135,13.598,,,
6236.22266,12.598,,,
6236.31445,12.598,,,
6236.40576,13.598,,,
6236.49756,13.598,,,
6236.58887,12.598,,,
6236.68066,13.598,,,
6236.77197,13.598,,,
6236.86328,12.598,,,
6236.95508,13.598,,,
6237.04639,13.598,,,
6237.13818,13.598,,,
6237.22949,13.598,,,
6237.32129,13.598,,,
6237.41260,13.598,,,
6237.50391,13.598,,,
6237.59570,13.598,,,
6237.68701,13.598,,,
6237.77881,13.598,,,
6237.87012,14.598,,,
6237.96191,13.598,,,
6238.05322,13.598,,,
6238.14453,13.598,,,
6238.23633,14.598,,,
6238.32764,13.598,,,
6238.41943,13.598,,,
6238.51074,13.598,,,
6238.60254,13.598,,,
6238.69385,13.598,,,
6238.78564,13.598,,,
6238.87695,13.598,,,
6238.96826,13.598,,,
6239.06006,13.598,,,
6239.15137,13.598,,,
6239.24316,12.598,,,
6239.33447,13.598,,,
6239.42627,13.598,,,
6239.51758,13.598,,,
6239.60889,13.598,,,
6239.70068,13.598,,,
6239.79199,13.598,,,
6239.88379,12.598,,,
6239.97510,13.598,,,
6240.06689,12.598,,,
6240.15820,13.598,,,
6240.24951,12.598,,,
6240.34131,13.598,,,
6240.43262,14.598,,,
6240.52441,13.598,,,
6240.61572,13.598,,,
6240.70752,13.598,,,
6240.79883,13.598,,,
6240.89063,13.598,,,
6240.98193,13.598,,,
6241.07324,13.598,,,
6241.16504,13.598,,,
6241.25635,12.598,,,
6241.34814,13.598,,,
6241.43945,13.598,,,
6241.53125,13.598,,,
6241.62256,13.598,,,
6241.71387,13.598,,,
6241.80566,13.598,,,
6241.89697,14.598,,,
6241.98877,13.598,,,
6242.08008,13.598,,,
6242.17188,13.598,,,
6242.26318,13.598,,,
6242.35449,13.598,,,
6242.44629,13.598,,,
6242.53760,13.598,,,
6242.62939,13.598,,,
6242.72070,12.598,,,
6242.81250,12.598,,,
6242.90381,13.598,,,
6242.99512,12.598,,,
6243.08691,13.598,,,
6243.17822,12.598,,,
6243.27002,12.598,,,
6243.36133,12.598,,,
6243.45313,13.598,,,
6243.54443,12.598,,,
6243.63623,12.598,,,
6243.72754,13.598,,,
6243.81885,13.598,,,
6243.91064,12.598,,,
6244.00195,12.598,,,
6244.09375,13.598,,,
6244.18506,12.598,,,
6244.27686,12.598,,,
6244.36816,12.598,,,
6244.45947,12.598,,,
6244.55127,12.598,,,
6244.64258,12.598,,,
6244.73438,12.598,,,
6244.82568,13.598,,,
6244.91748,13.598,,,
6245.00879,13.598,,,
6245.10010,12.598,,,
6245.19189,13.598,,,
6245.28320,13.598,,,
6245.37500,12.598,,,
6245.46631,12.598,,,
6245.55811,12.598,,,
6245.64941,13.598,,,
6245.74121,12.598,,,
6245.83252,12.598,,,
6245.92383,13.598,,,
6246.01563,12.598,,,
6246.10693,12.598,,,
6246.19873,13.598,,,
6246.29004,13.598,,,
6246.38184,12.598,,,
6246.47314,13.598,,,
6246.56445,12.598,,,
6246.65625,13.598,,,
6246.74756,12.598,,,
6246.83936,13.598,,,
6246.93066,12.598,,,
6247.02246,12.598,,,
6247.11377,12.598,,,
6247.20508,12.598,,,
6247.29688,12.598,,,
6247.38818,13.598,,,
6247.47998,12.598,,,
6247.57129,12.598,,,
6247.66309,12.598,,,
6247.75439,13.598,,,
6247.84619,13.598,,,
6247.93750,12.598,,,
6248.02881,12.598,,,
6248.12061,13.598,,,
6248.21191,12.598,,,
6248.30371,13.598,,,
6248.39502,13.598,,,
6248.48682,12.598,,,
6248.57813,12.598,,,
6248.66943,13.598,,,
6248.76123,12.598,,,
6248.85254,13.598,,,
6248.94434,12.598,,,
6249.03564,12.598,,,
6249.12744,12.598,,,
6249.21875,12.598,,,
6249.31006,12.598,,,
6249.40186,13.598,,,
6249.49316,13.598,,,
6249.58496,12.598,,,
6249.67627,12.598,,,
6249.76807,12.598,,,
6249.85938,12.598,,,
6249.95117,12.598,,,
6250.04248,12.598,,,
6250.13379,13.598,,,
6250.22559,12.598,,,
6250.31689,12.598,,,
6250.40869,12.598,,,
6250.50000,12.598,,,
6250.59180,12.598,,,
6250.68311,13.598,,,
6250.77441,12.598,,,
6250.86621,12.598,,,
6250.95752,12.598,,,
6251.04932,12.598,,,
6251.14063,12.598,,,
6251.23242,12.598,,,
6251.32373,12.598,,,
6251.41504,12.598,,,
6251.50684,11.598,,,
6251.59814,12.598,,,
6251.68994,12.598,,,
6251.78125,12.598,,,
6251.87305,12.598,,,
6251.96436,12.598,,,
6252.05615,12.598,,,
6252.14746,12.598,,,
6252.23877,12.598,,,
6252.33057,13.598,,,
6252.42188,12.598,,,
6252.51367,13.598,,,
6252.60498,14.598,,,
6252.69678,14.598,,,
6252.78809,13.598,,,
6252.87939,14.598,,,
6252.97119,13.598,,,
6253.06250,13.598,,,
6253.15430,13.598,,,
6253.24561,13.598,,,
6253.33740,13.598,,,
6253.42871,12.598,,,
6253.52002,13.598,,,
6253.61182,13.598,,,
6253.70313,12.598,,,
6253.79492,12.598,,,
6253.88623,13.598,,,
6253.97803,12.598,,,
6254.06934,12.598,,,
6254.16064,12.598,,,
6254.25244,12.598,,,
6254.34375,12.598,,,
6254.43555,12.598,,,
6254.52686,12.598,,,
6254.61865,12.598,,,
6254.70996,12.598,,,
6254.80176,12.598,,,
6254.89307,12.598,,,
6254.98438,12.598,,,
6255.07617,13.598,,,
6255.16748,11.598,,,
6255.25928,12.598,,,
6255.35059,12.598,,,
6255.44238,12.598,,,
6255.53369,12.598,,,
6255.62500,12.598,,,
6255.71680,12.598,,,
6255.80811,12.598,,,
6255.89990,12.598,,,
6255.99121,12.598,,,
6256.08301,11.598,,,
6256.17432,12.598,,,
6256.26563,12.598,,,
6256.35742,12.598,,,
6256.44873,11.598,,,
6256.54053,12.598,,,
6256.63184,12.598,,,
6256.72363,12.598,,,
6256.81494,11.598,,,
6256.90674,12.598,,,
6256.99805,12.598,,,
6257.08936,12.598,,,
6257.18115,12.598,,,
6257.27246,12.598,,,
6257.36426,12.598,,,
6257.45557,12.598,,,
6257.54736,12.598,,,
6257.63867,11.598,,,
6257.72998,12.598,,,
6257.82178,12.598,,,
6257.91309,12.598,,,
6258.00488,12.598,,,
6258.09619,12.598,,,
6258.18799,12.598,,,
6258.27930,12.598,,,
6258.37061,12.598,,,
6258.46240,12.598,,,
6258.55371,12.598,,,
6258.64551,12.598,,,
6258.73682,11.598,,,
6258.82861,12.598,,,
6258.91992,11.598,,,
6259.01172,11.598,,,
6259.10303,12.598,,,
6259.19434,12.598,,,
6259.28613,12.598,,,
6259.37744,11.598,,,
6259.46924,12.598,,,
6259.56055,12.598,,,
6259.65234,12.598,,,
6259.74365,12.598,,,
6259.83496,11.598,,,
6259.92676,12.598,,,
6260.01807,12.598,,,
6260.10986,11.598,,,
6260.20117,12.598,,,
6260.29297,11.598,,,
6260.38428,12.598,,,
6260.47559,11.598,,,
6260.56738,11.598,,,
6260.65869,12.598,,,
6260.75049,11.598,,,
6260.84180,11.598,,,
6260.93359,12.598,,,
6261.02490,11.598,,,
6261.11670,11.598,,,
6261.20801,12.598,,,
6261.29932,11.598,,,
6261.39111,11.598,,,
6261.48242,11.598,,,
6261.57422,11.598,,,
6261.66553,11.598,,,
6261.75732,11.598,,,
6261.84863,11.598,,,
6261.93994,11.598,,,
6262.03174,11.598,,,
6262.12305,11.598,,,
6262.21484,11.598,,,
6262.30615,12.598,,,
6262.39795,12.598,,,
6262.48926,12.598,,,
6262.58057,11.598,,,
6262.67236,12.598,,,
6262.76367,12.598,,,
6262.85547,11.598,,,
6262.94678,11.598,,,
6263.03857,12.598,,,
6263.12988,12.598,,,
6263.22168,11.598,,,
6263.31299,12.598,,,
6263.40430,12.598,,,
6263.49609,11.598,,,
6263.58740,11.598,,,
6263.67920,12.598,,,
6263.77051,11.598,,,
6263.86230,12.598,,,
6263.95361,11.598,,,
6264.04492,12.598,,,
6264.13672,11.598,,,
6264.22803,11.598,,,
6264.31982,11.598,,,
6264.41113,11.598,,,
6264.50293,11.598,,,
6264.59424,11.598,,,
6264.68555,11.598,,,
6264.77734,11.598,,,
6264.86865,12.598,,,
6264.96045,11.598,,,
6265.05176,11.598,,,
6265.14355,11.598,,,
6265.23486,12.598,,,
6265.32666,12.598,,,
6265.41797,11.598,,,
6265.50928,11.598,,,
6265.60107,11.598,,,
6265.69238,11.598,,,
6265.78418,11.598,,,
6265.87549,11.598,,,
6265.96729,11.598,,,
6266.05859,12.598,,,
6266.14990,12.598,,,
6266.24170,11.598,,,
6266.33301,11.598,,,
6266.42480,11.598,,,
6266.51611,11.598,,,
6266.60791,11.598,,,
6266.69922,12.598,,,
6266.79053,12.598,,,
6266.88232,11.598,,,
6266.97363,11.598,,,
6267.06543,12.598,,,
6267.15674,12.598,,,
6267.24854,12.598,,,
6267.33984,11.598,,,
6267.43115,12.598,,,
6267.52295,12.598,,,
6267.61426,11.598,,,
6267.70605,11.598,,,
6267.79736,11.598,,,
6267.88916,12.598,,,
6267.98047,12.598,,,
6268.07227,11.598,,,
6268.16357,11.598,,,
6268.25488,12.598,,,
6268.34668,11.598,,,
6268.43799,11.598,,,
6268.52979,11.598,,,
6268.62109,11.598,,,
6268.71289,11.598,,,
6268.80420,11.598,,,
6268.89551,11.598,,,
6268.98730,11.598,,,
6269.07861,11.598,,,
6269.17041,11.598,,,
6269.26172,11.598,,,
6269.35352,11.598,,,
6269.44482,11.598,,,
6269.53613,11.598,,,
6269.62793,11.598,,,
6269.71924,12.598,,,
6269.81104,11.598,,,
6269.90234,11.598,,,
6269.99414,11.598,,,
6270.08545,11.598,,,
6270.17725,12.598,,,
6270.26855,11.598,,,
6270.35986,11.598,,,
6270.45166,12.598,,,
6270.54297,11.598,,,
6270.63477,11.598,,,
6270.72607,11.598,,,
6270.81787,11.598,,,
6270.90918,11.598,,,
6271.00049,12.598,,,
6271.09229,11.598,,,
6271.18359,11.598,,,
6271.27539,11.598,,,
6271.36670,11.598,,,
6271.45850,11.598,,,
6271.54980,11.598,,,
6271.64111,11.598,,,
6271.73291,10.598,,,
6271.82422,11.598,,,
6271.91602,11.598,,,
6272.00732,11.598,,,
6272.09912,11.598,,,
6272.19043,11.598,,,
6272.28223,11.598,,,
6272.37354,10.598,,,
6272.46484,11.598,,,
6272.55664,10.598,,,
6272.64795,11.598,,,
6272.73975,11.598,,,
6272.83105,11.598,,,
6272.92285,11.598,,,
6273.01416,11.598,,,
6273.10547,11.598,,,
6273.19727,12.598,,,
6273.28857,12.598,,,
6273.38037,12.598,,,
6273.47168,13.598,,,
6273.56348,13.598,,,
6273.65479,12.598,,,
6273.74609,13.598,,,
6273.83789,12.598,,,
6273.92920,11.598,,,
6274.02100,12.598,,,
6274.11230,12.598,,,
6274.20410,11.598,,,
6274.29541,11.598,,,
6274.38721,11.598,,,
6274.47852,11.598,,,
6274.56982,10.598,,,
6274.66162,11.598,,,
6274.75293,11.598,,,
6274.84473,11.598,,,
6274.93604,11.598,,,
6275.02783,11.598,,,
6275.11914,11.598,,,
6275.21045,11.598,,,
6275.30225,11.598,,,
6275.39355,11.598,,,
6275.48535,10.598,,,
6275.57666,11.598,,,
6275.66846,11.598,,,
6275.75977,10.598,,,
6275.85107,11.598,,,
6275.94287,11.598,,,
6276.03418,11.598,,,
6276.12598,11.598,,,
6276.21729,11.598,,,
6276.30908,11.598,,,
6276.40039,11.598,,,
6276.49219,11.598,,,
6276.58350,11.598,,,
6276.67480,10.598,,,
6276.76660,11.598,,,
6276.85791,11.598,,,
6276.94971,11.598,,,
6277.04102,11.598,,,
6277.13281,11.598,,,
6277.22412,11.598,,,
6277.31543,11.598,,,
6277.40723,11.598,,,
6277.49854,11.598,,,
6277.59033,11.598,,,
6277.68164,11.598,,,
6277.77344,11.598,,,
6277.86475,11.598,,,
6277.95605,11.598,,,
6278.04785,11.598,,,
6278.13916,11.598,,,
6278.23096,10.598,,,
6278.32227,11.598,,,
6278.41406,11.598,,,
6278.50537,11.598,,,
6278.59668,11.598,,,
6278.68848,10.598,,,
6278.77979,11.598,,,
6278.87158,11.598,,,
6278.96289,11.598,,,
6279.05469,11.598,,,
6279.14600,11.598,,,
6279.23779,11.598,,,
6279.32910,11.598,,,
6279.42041,11.598,,,
6279.51221,11.598,,,
6279.60352,11.598,,,
6279.69531,11.598,,,
6279.78662,11.598,,,
6279.87842,11.598,,,
6279.96973,11.598,,,
6280.06104,11.598,,,
6280.15283,11.598,,,
6280.24414,11.598,,,
6280.33594,11.598,,,
6280.42725,11.598,,,
6280.51904,11.598,,,
6280.61035,11.598,,,
6280.70166,10.598,,,
6280.79346,11.598,,,
6280.88477,11.598,,,
6280.97656,10.598,,,
6281.06787,11.598,,,
6281.15967,11.598,,,
6281.25098,10.598,,,
6281.34277,11.598,,,
6281.43408,11.598,,,
6281.52539,11.598,,,
6281.61719,11.598,,,
6281.70850,11.598,,,
6281.80029,11.598,,,
6281.89160,11.598,,,
6281.98340,11.598,,,
6282.07471,11.598,,,
6282.16602,10.598,,,
6282.25781,11.598,,,
6282.34912,11.598,,,
6282.44092,11.598,,,
6282.53223,11.598,,,
6282.62402,11.598,,,
6282.71533,10.598,,,
6282.80664,10.598,,,
6282.89844,11.598,,,
6282.98975,10.598,,,
6283.08154,11.598,,,
6283.17285,10.598,,,
6283.26465,11.598,,,
6283.35596,11.598,,,
6283.44775,10.598,,,
6283.53906,11.598,,,
6283.63037,11.598,,,
6283.72217,10.598,,,
6283.81348,11.598,,,
6283.90527,11.598,,,
6283.99658,10.598,,,
6284.08838,11.598,,,
6284.17969,11.598,,,
6284.27100,11.598,,,
6284.36279,11.598,,,
6284.45410,11.598,,,
6284.54590,11.598,,,
6284.63721,10.598,,,
6284.72900,11.598,,,
6284.82031,11.598,,,
6284.91162,10.598,,,
6285.00342,10.598,,,
6285.09473,11.598,,,
6285.18652,10.598,,,
6285.27783,10.598,,,
6285.36963,10.598,,,
6285.46094,10.598,,,
6285.55273,10.598,,,
6285.64404,10.598,,,
6285.73535,10.598,,,
6285.82715,11.598,,,
6285.91846,11.598,,,
6286.01025,11.598,,,
6286.10156,11.598,,,
6286.19336,10.598,,,
6286.28467,11.598,,,
6286.37598,11.598,,,
6286.46777,11.598,,,
6286.55908,11.598,,,
6286.65088,11.598,,,
6286.74219,11.598,,,
6286.83398,10.598,,,
6286.92529,11.598,,,
6287.01660,11.598,,,
6287.10840,11.598,,,
6287.19971,11.598,,,
6287.29150,11.598,,,
6287.38281,10.598,,,
6287.47461,11.598,,,
6287.56592,11.598,,,
6287.65771,11.598,,,
6287.74902,10.598,,,
6287.84033,11.598,,,
6287.93213,10.598,,,
6288.02344,11.598,,,
6288.11523,10.598,,,
6288.20654,11.598,,,
6288.29834,10.598,,,
6288.38965,11.598,,,
6288.48096,11.598,,,
6288.57275,10.598,,,
6288.66406,10.598,,,
6288.75586,11.598,,,
6288.84717,11.598,,,
6288.93896,11.598,,,
6289.03027,10.598,,,
6289.12158,11.598,,,
6289.21338,10.598,,,
6289.30469,11.598,,,
6289.39648,11.598,,,
6289.48779,11.598,,,
6289.57959,10.598,,,
6289.67090,10.598,,,
6289.76270,11.598,,,
6289.85400,11.598,,,
6289.94531,11.598,,,
6290.03711,11.598,,,
6290.12842,10.598,,,
6290.22021,11.598,,,
6290.31152,11.598,,,
6290.40332,11.598,,,
6290.49463,11.598,,,
6290.58594,10.598,,,
6290.67773,11.598,,,
6290.76904,11.598,,,
6290.86084,11.598,,,
6290.95215,11.598,,,
6291.04395,10.598,,,
6291.13525,10.598,,,
6291.22656,10.598,,,
6291.31836,10.598,,,
6291.40967,10.598,,,
6291.50146,11.598,,,
6291.59277,11.598,,,
6291.68457,11.598,,,
6291.77588,11.598,,,
6291.86719,11.598,,,
6291.95898,11.598,,,
6292.05029,10.598,,,
6292.14209,11.598,,,
6292.23340,10.598,,,
6292.32520,11.598,,,
6292.41650,11.598,,,
6292.50830,11.598,,,
6292.59961,11.598,,,
6292.69092,11.598,,,
6292.78271,11.598,,,
6292.87402,11.598,,,
6292.96582,11.598,,,
6293.05713,11.598,,,
6293.14893,11.598,,,
6293.24023,10.598,,,
6293.33154,11.598,,,
6293.42334,10.598,,,
6293.51465,11.598,,,
6293.60645,10.598,,,
6293.69775,11.598,,,
6293.78955,11.598,,,
6293.88086,10.598,,,
6293.97217,10.598,,,
6294.06396,10.598,,,
6294.15527,10.598,,,
6294.24707,10.598,,,
6294.33838,10.598,,,
6294.43018,10.598,,,
6294.52148,10.598,,,
6294.61328,11.598,,,
6294.70459,12.598,,,
6294.79590,11.598,,,
6294.88770,12.598,,,
6294.97900,12.598,,,
6295.07080,12.598,,,
6295.16211,12.598,,,
6295.25391,12.598,,,
6295.34521,11.598,,,
6295.43652,11.598,,,
6295.52832,11.598,,,
6295.61963,11.598,,,
6295.71143,10.598,,,
6295.80273,10.598,,,
6295.89453,11.598,,,
6295.98584,10.598,,,
6296.07715,11.598,,,
6296.16895,11.598,,,
6296.26025,11.598,,,
6296.35205,10.598,,,
6296.44336,10.598,,,
6296.53516,10.598,,,
6296.62646,10.598,,,
6296.71826,10.598,,,
6296.80957,10.598,,,
6296.90088,10.598,,,
6296.99268,10.598,,,
6297.08398,10.598,,,
6297.17578,10.598,,,
6297.26709,10.598,,,
6297.35889,10.598,,,
6297.45020,10.598,,,
6297.54150,10.598,,,
6297.63330,10.598,,,
6297.72461,10.598,,,
6297.81641,10.598,,,
6297.90771,10.598,,,
6297.99951,11.598,,,
6298.09082,10.598,,,
6298.18213,11.598,,,
6298.27393,10.598,,,
6298.36523,10.598,,,
6298.45703,10.598,,,
6298.54834,10.598,,,
6298.64014,10.598,,,
6298.73145,10.598,,,
6298.82324,10.598,,,
6298.91455,10.598,,,
6299.00586,10.598,,,
6299.09766,10.598,,,
6299.18896,10.598,,,
6299.28076,10.598,,,
6299.37207,10.598,,,
6299.46387,10.598,,,
6299.55518,11.598,,,
6299.64648,11.598,,,
6299.73828,10.598,,,
6299.82959,10.598,,,
6299.92139,10.598,,,
6300.01270,11.598,,,
6300.10449,11.598,,,
6300.19580,11.598,,,
6300.28711,11.598,,,
6300.37891,10.598,,,
6300.47021,11.598,,,
6300.56201,11.598,,,
6300.65332,9.598,,,
6300.74512,10.598,,,
6300.83643,10.598,,,
6300.92822,10.598,,,
6301.01953,10.598,,,
6301.11084,10.598,,,
6301.20264,10.598,,,
6301.29395,10.598,,,
6301.38574,10.598,,,
6301.47705,10.598,,,
6301.56885,10.598,,,
6301.66016,10.598,,,
6301.75146,10.598,,,
6301.84326,10.598,,,
6301.93457,11.598,,,
6302.02637,11.598,,,
6302.11768,10.598,,,
6302.20947,10.598,,,
6302.30078,10.598,,,
6302.39209,10.598,,,
6302.48389,10.598,,,
6302.57520,10.598,,,
6302.66699,10.598,,,
6302.75830,9.598,,,
6302.85010,10.598,,,
6302.94141,10.598,,,
6303.03320,9.598,,,
6303.12451,10.598,,,
6303.21582,10.598,,,
6303.30762,10.598,,,
6303.39893,11.598,,,
6303.49072,10.598,,,
6303.58203,10.598,,,
6303.67383,10.598,,,
6303.76514,10.598,,,
6303.85645,11.598,,,
6303.94824,10.598,,,
6304.03955,10.598,,,
6304.13135,11.598,,,
6304.22266,10.598,,,
6304.31445,10.598,,,
6304.40576,10.598,,,
6304.49707,10.598,,,
6304.58887,10.598,,,
6304.68018,10.598,,,
6304.77197,10.598,,,
6304.86328,10.598,,,
6304.95508,10.598,,,
6305.04639,10.598,,,
6305.13770,10.598,,,
6305.22949,10.598,,,
6305.32080,10.598,,,
6305.41260,10.598,,,
6305.50391,10.598,,,
6305.59570,10.598,,,
6305.68701,10.598,,,
6305.77881,10.598,,,
6305.87012,10.598,,,
6305.96143,10.598,,,
6306.05322,10.598,,,
6306.14453,10.598,,,
6306.23633,10.598,,,
6306.32764,11.598,,,
6306.41943,10.598,,,
6306.51074,10.598,,,
6306.60205,10.598,,,
6306.69385,10.598,,,
6306.78516,10.598,,,
6306.87695,10.598,,,
6306.96826,10.598,,,
6307.06006,10.598,,,
6307.15137,9.598,,,
6307.24268,10.598,,,
6307.33447,9.598,,,
6307.42578,10.598,,,
6307.51758,10.598,,,
6307.60889,9.598,,,
6307.70068,10.598,,,
6307.79199,10.598,,,
6307.88379,10.598,,,
6307.97510,10.598,,,
6308.06641,10.598,,,
6308.15820,10.598,,,
6308.24951,9.598,,,
6308.34131,10.598,,,
6308.43262,10.598,,,
6308.52441,10.598,,,
6308.61572,9.598,,,
6308.70703,9.598,,,
6308.79883,10.598,,,
6308.89014,10.598,,,
6308.98193,10.598,,,
6309.07324,10.598,,,
6309.16504,9.598,,,
6309.25635,10.598,,,
6309.34766,10.598,,,
6309.43945,9.598,,,
6309.53076,9.598,,,
6309.62256,9.598,,,
6309.71387,10.598,,,
6309.80566,10.598,,,
6309.89697,10.598,,,
6309.98877,9.598,,,
6310.08008,10.598,,,
6310.17139,10.598,,,
6310.26318,10.598,,,
6310.35449,9.598,,,
6310.44629,10.598,,,
6310.53760,10.598,,,
6310.62939,10.598,,,
6310.72070,10.598,,,
6310.81201,10.598,,,
6310.90381,10.598,,,
6310.99512,10.598,,,
6311.08691,9.598,,,
6311.17822,10.598,,,
6311.27002,9.598,,,
6311.36133,9.598,,,
6311.45264,10.598,,,
6311.54443,10.598,,,
6311.63574,9.598,,,
6311.72754,9.598,,,
6311.81885,10.598,,,
6311.91064,9.598,,,
6312.00195,9.598,,,
6312.09375,9.598,,,
6312.18506,10.598,,,
6312.27637,9.598,,,
6312.36816,9.598,,,
6312.45947,10.598,,,
6312.55127,9.598,,,
6312.64258,9.598,,,
6312.73438,10.598,,,
6312.82568,9.598,,,
6312.91699,9.598,,,
6313.00879,10.598,,,
6313.10010,9.598,,,
6313.19189,9.598,,,
6313.28320,10.598,,,
6313.37500,10.598,,,
6313.46631,9.598,,,
6313.55762,10.598,,,
6313.64941,10.598,,,
6313.74072,10.598,,,
6313.83252,9.598,,,
6313.92383,10.598,,,
6314.01563,10.598,,,
6314.10693,9.598,,,
6314.19873,10.598,,,
6314.29004,10.598,,,
6314.38135,9.598,,,
6314.47314,9.598,,,
6314.56445,10.598,,,
6314.65625,9.598,,,
6314.74756,9.598,,,
6314.83936,9.598,,,
6314.93066,9.598,,,
6315.02197,9.598,,,
6315.11377,10.598,,,
6315.20508,10.598,,,
6315.29688,9.598,,,
6315.38818,9.598,,,
6315.47998,10.598,,,
6315.57129,9.598,,,
6315.66260,9.598,,,
6315.75439,9.598,,,
6315.84570,9.598,,,
6315.93750,9.598,,,
6316.02881,10.598,,,
6316.12061,9.598,,,
6316.21191,9.598,,,
6316.30322,9.598,,,
6316.39502,9.598,,,
6316.48633,9.598,,,
6316.57813,10.598,,,
6316.66943,10.598,,,
6316.76123,9.598,,,
6316.85254,9.598,,,
6316.94434,9.598,,,
6317.03564,9.598,,,
6317.12695,8.598,,,
6317.21875,8.598,,,
6317.31006,9.598,,,
6317.40186,8.598,,,
6317.49316,8.598,,,
6317.58496,8.598,,,
6317.67627,8.598,,,
6317.76758,8.598,,,
6317.85938,9.598,,,
6317.95068,9.598,,,
6318.04248,10.598,,,
6318.13379,9.598,,,
6318.22559,9.598,,,
6318.31689,9.598,,,
6318.40820,9.598,,,
6318.50000,9.598,,,
6318.59131,9.598,,,
6318.68311,9.598,,,
6318.77441,9.598,,,
6318.86621,9.598,,,
6318.95752,9.598,,,
6319.04932,9.598,,,
6319.14063,9.598,,,
6319.23193,9.598,,,
6319.32373,9.598,,,
6319.41504,9.598,,,
6319.50684,10.598,,,
6319.59814,9.598,,,
6319.68994,9.598,,,
6319.78125,9.598,,,
6319.87256,9.598,,,
6319.96436,10.598,,,
6320.05566,9.598,,,
6320.14746,9.598,,,
6320.23877,9.598,,,
6320.33057,9.598,,,
6320.42188,9.598,,,
6320.51318,9.598,,,
6320.60498,9.598,,,
6320.69629,9.598,,,
6320.78809,10.598,,,
6320.87939,9.598,,,
6320.97119,9.598,,,
6321.06250,9.598,,,
6321.15430,9.598,,,
6321.24561,9.598,,,
6321.33691,10.598,,,
6321.42871,9.598,,,
6321.52002,9.598,,,
6321.61182,10.598,,,
6321.70313,9.598,,,
6321.79492,9.598,,,
6321.88623,9.598,,,
6321.97754,9.598,,,
6322.06934,9.598,,,
6322.16064,9.598,,,
6322.25244,9.598,,,
6322.34375,9.598,,,
6322.43555,10.598,,,
6322.52686,9.598,,,
6322.61816,9.598,,,
6322.70996,9.598,,,
6322.80127,9.598,,,
6322.89307,9.598,,,
6322.98438,9.598,,,
6323.07617,9.598,,,
6323.16748,9.598,,,
6323.25928,9.598,,,
6323.35059,9.598,,,
6323.44189,9.598,,,
6323.53369,9.598,,,
6323.62500,9.598,,,
6323.71680,9.598,,,
6323.80811,9.598,,,
6323.89990,9.598,,,
6323.99121,9.598,,,
6324.08252,9.598,,,
6324.17432,9.598,,,
6324.26563,9.598,,,
6324.35742,9.598,,,
6324.44873,9.598,,,
6324.54053,9.598,,,
6324.63184,9.598,,,
6324.72314,9.598,,,
6324.81494,9.598,,,
6324.90625,8.598,,,
6324.99805,9.598,,,
6325.08936,9.598,,,
6325.18115,9.598,,,
6325.27246,9.598,,,
6325.36426,10.598,,,
6325.45557,9.598,,,
6325.54688,9.598,,,
6325.63867,9.598,,,
6325.72998,9.598,,,
6325.82178,9.598,,,
6325.91309,9.598,,,
6326.00488,9.598,,,
6326.09619,9.598,,,
6326.18750,9.598,,,
6326.27930,8.598,,,
6326.37061,9.598,,,
6326.46240,9.598,,,
6326.55371,9.598,,,
6326.64551,9.598,,,
6326.73682,9.598,,,
6326.82813,9.598,,,
6326.91992,9.598,,,
6327.01123,9.598,,,
6327.10303,9.598,,,
6327.19434,9.598,,,
6327.28613,9.598,,,
6327.37744,8.598,,,
6327.46924,9.598,,,
6327.56055,8.598,,,
6327.65186,9.598,,,
6327.74365,9.598,,,
6327.83496,9.598,,,
6327.92676,8.598,,,
6328.01807,9.598,,,
6328.10986,8.598,,,
6328.20117,9.598,,,
6328.29248,9.598,,,
6328.38428,9.598,,,
6328.47559,9.598,,,
6328.56738,9.598,,,
6328.65869,9.598,,,
6328.75049,9.598,,,
6328.84180,9.598,,,
6328.93311,9.598,,,
6329.02490,9.598,,,
6329.11621,8.598,,,
6329.20801,8.598,,,
6329.29932,8.598,,,
6329.39111,9.598,,,
6329.48242,9.598,,,
6329.57373,9.598,,,
6329.66553,9.598,,,
6329.75684,8.598,,,
6329.84863,9.598,,,
6329.93994,9.598,,,
6330.03174,9.598,,,
6330.12305,8.598,,,
6330.21484,9.598,,,
6330.30615,8.598,,,
6330.39746,8.598,,,
6330.48926,9.598,,,
6330.58057,9.598,,,
6330.67236,8.598,,,
6330.76367,9.598,,,
6330.85547,8.598,,,
6330.94678,9.598,,,
6331.03809,9.598,,,
6331.12988,9.598,,,
6331.22119,10.598,,,
6331.31299,8.598,,,
6331.40430,9.598,,,
6331.49609,9.598,,,
6331.58740,9.598,,,
6331.67871,9.598,,,
6331.77051,9.598,,,
6331.86182,8.598,,,
6331.95361,8.598,,,
6332.04492,9.598,,,
6332.13672,9.598,,,
6332.22803,8.598,,,
6332.31982,9.598,,,
6332.41113,9.598,,,
6332.50244,8.598,,,
6332.59424,8.598,,,
6332.68555,10.598,,,
6332.77734,8.598,,,
6332.86865,9.598,,,
6332.96045,9.598,,,
6333.05176,9.598,,,
6333.14307,8.598,,,
6333.23486,9.598,,,
6333.32617,8.598,,,
6333.41797,8.598,,,
6333.50928,8.598,,,
6333.60107,9.598,,,
6333.69238,8.598,,,
6333.78369,8.598,,,
6333.87549,8.598,,,
6333.96680,9.598,,,
6334.05859,9.598,,,
6334.14990,9.598,,,
6334.24170,9.598,,,
6334.33301,9.598,,,
6334.42480,9.598,,,
6334.51611,9.598,,,
6334.60742,9.598,,,
6334.69922,8.598,,,
6334.79053,8.598,,,
6334.88232,8.598,,,
6334.97363,8.598,,,
6335.06543,8.598,,,
6335.15674,8.598,,,
6335.24805,8.598,,,
6335.33984,8.598,,,
6335.43115,8.598,,,
6335.52295,9.598,,,
6335.61426,9.598,,,
6335.70605,9.598,,,
6335.79736,9.598,,,
6335.88867,8.598,,,
6335.98047,9.598,,,
6336.07178,9.598,,,
6336.16357,9.598,,,
6336.25488,8.598,,,
6336.34668,9.598,,,
6336.43799,9.598,,,
6336.52979,8.598,,,
6336.62109,8.598,,,
6336.71240,9.598,,,
6336.80420,8.598,,,
6336.89551,8.598,,,
6336.98730,8.598,,,
6337.07861,9.598,,,
6337.17041,8.598,,,
6337.26172,9.598,,,
6337.35303,8.598,,,
6337.44482,8.598,,,
6337.53613,8.598,,,
6337.62793,8.598,,,
6337.71924,7.598,,,
6337.81104,8.598,,,
6337.90234,8.598,,,
6337.99365,8.598,,,
6338.08545,7.598,,,
6338.17676,8.598,,,
6338.26855,8.598,,,
6338.35986,8.598,,,
6338.45166,8.598,,,
6338.54297,9.598,,,
6338.63477,8.598,,,
6338.72607,8.598,,,
6338.81738,8.598,,,
6338.90918,8.598,,,
6339.00049,8.598,,,
6339.09229,8.598,,,
6339.18359,9.598,,,
6339.27539,8.598,,,
6339.36670,8.598,,,
6339.45801,9.598,,,
6339.54980,8.598,,,
6339.64111,9.598,,,
6339.73291,8.598,,,
6339.82422,8.598,,,
6339.91602,8.598,,,
6340.00732,9.598,,,
6340.09863,8.598,,,
6340.19043,8.598,,,
6340.28174,8.598,,,
6340.37354,8.598,,,
6340.46484,8.598,,,
6340.55664,8.598,,,
6340.64795,8.598,,,
6340.73975,8.598,,,
6340.83105,8.598,,,
6340.92236,8.598,,,
6341.01416,8.598,,,
6341.10547,8.598,,,
6341.19727,8.598,,,
6341.28857,8.598,,,
6341.38037,8.598,,,
6341.47168,8.598,,,
6341.56299,8.598,,,
6341.65479,8.598,,,
6341.74609,8.598,,,
6341.83789,8.598,,,
6341.92920,8.598,,,
6342.02100,8.598,,,
6342.11230,8.598,,,
6342.20361,9.598,,,
6342.29541,8.598,,,
6342.38672,8.598,,,
6342.47852,8.598,,,
6342.56982,8.598,,,
6342.66162,8.598,,,
6342.75293,8.598,,,
6342.84424,8.598,,,
6342.93604,9.598,,,
6343.02734,8.598,,,
6343.11914,8.598,,,
6343.21045,8.598,,,
6343.30225,8.598,,,
6343.39355,8.598,,,
6343.48535,8.598,,,
6343.57666,8.598,,,
6343.66797,8.598,,,
6343.75977,8.598,,,
6343.85107,8.598,,,
6343.94287,8.598,,,
6344.03418,8.598,,,
6344.12598,8.598,,,
6344.21729,8.598,,,
6344.30859,8.598,,,
6344.40039,9.598,,,
6344.49170,8.598,,,
6344.58350,8.598,,,
6344.67480,8.598,,,
6344.76660,8.598,,,
6344.85791,8.598,,,
6344.94922,8.598,,,
6345.04102,8.598,,,
6345.13232,8.598,,,
6345.22412,8.598,,,
6345.31543,8.598,,,
6345.40723,8.598,,,
6345.49854,8.598,,,
6345.59033,8.598,,,
6345.68164,8.598,,,
6345.77295,7.598,,,
6345.86475,8.598,,,
6345.95605,8.598,,,
6346.04785,8.598,,,
6346.13916,8.598,,,
6346.23096,8.598,,,
6346.32227,8.598,,,
6346.41357,8.598,,,
6346.50537,8.598,,,
6346.59668,7.598,,,
6346.68848,8.598,,,
6346.77979,8.598,,,
6346.87158,8.598,,,
6346.96289,8.598,,,
6347.05420,8.598,,,
6347.14600,7.598,,,
6347.23730,8.598,,,
6347.32910,8.598,,,
6347.42041,8.598,,,
6347.51221,8.598,,,
6347.60352,8.598,,,
6347.69531,8.598,,,
6347.78662,8.598,,,
6347.87793,8.598,,,
6347.96973,8.598,,,
6348.06104,8.598,,,
6348.15283,8.598,,,
6348.24414,8.598,,,
6348.33594,8.598,,,
6348.42725,8.598,,,
6348.51855,8.598,,,
6348.61035,8.598,,,
6348.70166,8.598,,,
6348.79346,9.598,,,
6348.88477,8.598,,,
6348.97656,8.598,,,
6349.06787,8.598,,,
6349.15918,8.598,,,
6349.25098,8.598,,,
6349.34229,8.598,,,
6349.43408,8.598,,,
6349.52539,8.598,,,
6349.61719,8.598,,,
6349.70850,7.598,,,
6349.80029,8.598,,,
6349.89160,7.598,,,
6349.98291,8.598,,,
6350.07471,7.598,,,
6350.16602,7.598,,,
6350.25781,8.598,,,
6350.34912,7.598,,,
6350.44092,8.598,,,
6350.53223,7.598,,,
6350.62354,7.598,,,
6350.71533,8.598,,,
6350.80664,8.598,,,
6350.89844,8.598,,,
6350.98975,7.598,,,
6351.08154,7.598,,,
6351.17285,7.598,,,
6351.26416,7.598,,,
6351.35596,8.598,,,
6351.44727,7.598,,,
6351.53906,8.598,,,
6351.63037,8.598,,,
6351.72217,8.598,,,
6351.81348,8.598,,,
6351.90527,7.598,,,
6351.99658,7.598,,,
6352.08789,8.598,,,
6352.17969,7.598,,,
6352.27100,7.598,,,
6352.36279,8.598,,,
6352.45410,7.598,,,
6352.54590,7.598,,,
6352.63721,7.598,,,
6352.72852,7.598,,,
6352.82031,7.598,,,
6352.91162,8.598,,,
6353.00342,7.598,,,
6353.09473,7.598,,,
6353.18652,8.598,,,
6353.27783,7.598,,,
6353.36914,8.598,,,
6353.46094,8.598,,,
6353.55225,7.598,,,
6353.64404,8.598,,,
6353.73535,7.598,,,
6353.82715,8.598,,,
6353.91846,7.598,,,
6354.00977,7.598,,,
6354.10156,7.598,,,
6354.19287,8.598,,,
6354.28467,7.598,,,
6354.37598,8.598,,,
6354.46777,7.598,,,
6354.55908,8.598,,,
6354.65088,8.598,,,
6354.74219,8.598,,,
6354.83350,8.598,,,
6354.92529,7.598,,,
6355.01660,8.598,,,
6355.10840,8.598,,,
6355.19971,8.598,,,
6355.29150,8.598,,,
6355.38281,8.598,,,
6355.47412,7.598,,,
6355.56592,7.598,,,
6355.65723,8.598,,,
6355.74902,8.598,,,
6355.84033,7.598,,,
6355.93213,7.598,,,
6356.02344,8.598,,,
6356.11475,8.598,,,
6356.20654,8.598,,,
6356.29785,7.598,,,
6356.38965,7.598,,,
6356.48096,7.598,,,
6356.57275,7.598,,,
6356.66406,7.598,,,
6356.75586,7.598,,,
6356.84717,7.598,,,
6356.93848,7.598,,,
6357.03027,7.598,,,
6357.12158,7.598,,,
6357.21338,8.598,,,
6357.30469,7.598,,,
6357.39648,7.598,,,
6357.48779,7.598,,,
6357.57910,8.598,,,
6357.67090,7.598,,,
6357.76221,7.598,,,
6357.85400,8.598,,,
6357.94531,7.598,,,
6358.03711,8.598,,,
6358.12842,7.598,,,
6358.21973,7.598,,,
6358.31152,7.598,,,
6358.40283,8.598,,,
6358.49463,7.598,,,
6358.58594,7.598,,,
6358.67773,7.598,,,
6358.76904,8.598,,,
6358.86084,7.598,,,
6358.95215,7.598,,,
6359.04346,8.598,,,
6359.13525,7.598,,,
6359.22656,7.598,,,
6359.31836,7.598,,,
6359.40967,7.598,,,
6359.50146,7.598,,,
6359.59277,7.598,,,
6359.68408,7.598,,,
6359.77588,7.598,,,
6359.86719,7.598,,,
6359.95898,7.598,,,
6360.05029,7.598,,,
6360.14209,7.598,,,
6360.23340,8.598,,,
6360.32471,8.598,,,
6360.41650,8.598,,,
6360.50781,9.598,,,
6360.59961,8.598,,,
6360.69092,8.598,,,
6360.78271,8.598,,,
6360.87402,8.598,,,
6360.96582,8.598,,,
6361.05713,8.598,,,
6361.14844,8.598,,,
6361.24023,8.598,,,
6361.33154,7.598,,,
6361.42334,7.598,,,
6361.51465,8.598,,,
6361.60645,8.598,,,
6361.69775,7.598,,,
6361.78906,8.598,,,
6361.88086,7.598,,,
6361.97217,8.598,,,
6362.06396,7.598,,,
6362.15527,7.598,,,
6362.24707,7.598,,,
6362.33838,7.598,,,
6362.42969,7.598,,,
6362.52148,7.598,,,
6362.61279,7.598,,,
6362.70459,7.598,,,
6362.79590,7.598,,,
6362.88770,7.598,,,
6362.97900,7.598,,,
6363.07080,8.598,,,
6363.16211,7.598,,,
6363.25342,7.598,,,
6363.34521,7.598,,,
6363.43652,8.598,,,
6363.52832,7.598,,,
6363.61963,8.598,,,
6363.71143,8.598,,,
6363.80273,7.598,,,
6363.89404,7.598,,,
6363.98584,7.598,,,
6364.07715,7.598,,,
6364.16895,7.598,,,
6364.26025,8.598,,,
6364.35205,7.598,,,
6364.44336,7.598,,,
6364.53467,7.598,,,
6364.62646,6.598,,,
6364.71777,7.598,,,
6364.80957,7.598,,,
6364.90088,8.598,,,
6364.99268,7.598,,,
6365.08398,7.598,,,
6365.17578,8.598,,,
6365.26709,7.598,,,
6365.35840,7.598,,,
6365.45020,7.598,,,
6365.54150,7.598,,,
6365.63330,7.598,,,
6365.72461,7.598,,,
6365.81641,7.598,,,
6365.90771,7.598,,,
6365.99902,6.598,,,
6366.09082,7.598,,,
6366.18213,7.598,,,
6366.27393,6.598,,,
6366.36523,8.598,,,
6366.45703,7.598,,,
6366.54834,7.598,,,
6366.63965,7.598,,,
6366.73145,7.598,,,
6366.82275,7.598,,,
6366.91455,7.598,,,
6367.00586,7.598,,,
6367.09766,7.598,,,
6367.18896,6.598,,,
6367.28027,7.598,,,
6367.37207,7.598,,,
6367.46338,7.598,,,
6367.55518,7.598,,,
6367.64648,7.598,,,
6367.73828,7.598,,,
6367.82959,8.598,,,
6367.92139,7.598,,,
6368.01270,7.598,,,
6368.10400,7.598,,,
6368.19580,7.598,,,
6368.28711,6.598,,,
6368.37891,7.598,,,
6368.47021,7.598,,,
6368.56201,7.598,,,
6368.65332,7.598,,,
6368.74463,7.598,,,
6368.83643,7.598,,,
6368.92773,7.598,,,
6369.01953,7.598,,,
6369.11084,7.598,,,
6369.20264,7.598,,,
6369.29395,7.598,,,
6369.38525,7.598,,,
6369.47705,7.598,,,
6369.56836,7.598,,,
6369.66016,6.598,,,
6369.75146,7.598,,,
6369.84326,7.598,,,
6369.93457,6.598,,,
6370.02637,6.598,,,
6370.11768,7.598,,,
6370.20898,6.598,,,
6370.30078,6.598,,,
6370.39209,7.598,,,
6370.48389,7.598,,,
6370.57520,6.598,,,
6370.66699,7.598,,,
6370.75830,7.598,,,
6370.84961,6.598,,,
6370.94141,6.598,,,
6371.03271,7.598,,,
6371.12451,7.598,,,
6371.21582,7.598,,,
6371.30762,7.598,,,
6371.39893,7.598,,,
6371.49023,7.598,,,
6371.58203,7.598,,,
6371.67334,7.598,,,
6371.76514,7.598,,,
6371.85645,7.598,,,
6371.94824,7.598,,,
6372.03955,7.598,,,
6372.13135,7.598,,,
6372.22266,8.598,,,
6372.31396,6.598,,,
6372.40576,7.598,,,
6372.49707,7.598,,,
6372.58887,6.598,,,
6372.68018,7.598,,,
6372.77197,7.598,,,
6372.86328,7.598,,,
6372.95459,7.598,,,
6373.04639,6.598,,,
6373.13770,6.598,,,
6373.22949,7.598,,,
6373.32080,7.598,,,
6373.41260,6.598,,,
6373.50391,6.598,,,
6373.59521,7.598,,,
6373.68701,7.598,,,
6373.77832,7.598,,,
6373.87012,7.598,,,
6373.96143,7.598,,,
6374.05322,7.598,,,
6374.14453,7.598,,,
6374.23633,7.598,,,
6374.32764,7.598,,,
6374.41895,8.598,,,
6374.51074,6.598,,,
6374.60205,6.598,,,
6374.69385,7.598,,,
6374.78516,7.598,,,
6374.87695,7.598,,,
6374.96826,7.598,,,
6375.05957,7.598,,,
6375.15137,7.598,,,
6375.24268,7.598,,,
6375.33447,7.598,,,
6375.42578,7.598,,,
6375.51758,7.598,,,
6375.60889,7.598,,,
6375.70020,7.598,,,
6375.79199,7.598,,,
6375.88330,6.598,,,
6375.97510,7.598,,,
6376.06641,7.598,,,
6376.15820,7.598,,,
6376.24951,7.598,,,
6376.34131,7.598,,,
6376.43262,7.598,,,
6376.52393,7.598,,,
6376.61572,7.598,,,
6376.70703,6.598,,,
6376.79883,7.598,,,
6376.89014,7.598,,,
6376.98193,7.598,,,
6377.07324,7.598,,,
6377.16455,7.598,,,
6377.25635,7.598,,,
6377.34766,7.598,,,
6377.43945,7.598,,,
6377.53076,7.598,,,
6377.62256,7.598,,,
6377.71387,7.598,,,
6377.80518,6.598,,,
6377.89697,6.598,,,
6377.98828,7.598,,,
6378.08008,7.598,,,
6378.17139,6.598,,,
6378.26318,6.598,,,
6378.35449,7.598,,,
6378.44580,7.598,,,
6378.53760,6.598,,,
6378.62891,7.598,,,
6378.72070,6.598,,,
6378.81201,6.598,,,
6378.90381,7.598,,,
6378.99512,6.598,,,
6379.08691,6.598,,,
6379.17822,6.598,,,
6379.26953,7.598,,,
6379.36133,6.598,,,
6379.45264,6.598,,,
6379.54443,7.598,,,
6379.63574,6.598,,,
6379.72754,6.598,,,
6379.81885,6.598,,,
6379.91016,7.598,,,
6380.00195,6.598,,,
6380.09326,6.598,,,
6380.18506,7.598,,,
6380.27637,6.598,,,
6380.36816,6.598,,,
6380.45947,6.598,,,
6380.55078,6.598,,,
6380.64258,7.598,,,
6380.73389,6.598,,,
6380.82568,7.598,,,
6380.91699,7.598,,,
6381.00879,6.598,,,
6381.10010,6.598,,,
6381.19189,7.598,,,
6381.28320,6.598,,,
6381.37451,7.598,,,
6381.46631,6.598,,,
6381.55762,6.598,,,
6381.64941,6.598,,,
6381.74072,7.598,,,
6381.83252,7.598,,,
6381.92383,6.598,,,
6382.01514,7.598,,,
6382.10693,6.598,,,
6382.19824,6.598,,,
6382.29004,6.598,,,
6382.38135,6.598,,,
6382.47314,7.598,,,
6382.56445,6.598,,,
6382.65576,7.598,,,
6382.74756,7.598,,,
6382.83887,7.598,,,
6382.93066,7.598,,,
6383.02197,6.598,,,
6383.11377,6.598,,,
6383.20508,6.598,,,
6383.29688,6.598,,,
6383.38818,6.598,,,
6383.47949,6.598,,,
6383.57129,6.598,,,
6383.66260,6.598,,,
6383.75439,7.598,,,
6383.84570,6.598,,,
6383.93750,7.598,,,
6384.02881,7.598,,,
6384.12012,6.598,,,
6384.21191,7.598,,,
6384.30322,6.598,,,
6384.39502,7.598,,,
6384.48633,7.598,,,
6384.57813,7.598,,,
6384.66943,7.598,,,
6384.76074,7.598,,,
6384.85254,7.598,,,
6384.94385,6.598,,,
6385.03564,7.598,,,
6385.12695,6.598,,,
6385.21875,6.598,,,
6385.31006,6.598,,,
6385.40186,7.598,,,
6385.49316,6.598,,,
6385.58447,6.598,,,
6385.67627,6.598,,,
6385.76758,7.598,,,
6385.85938,6.598,,,
6385.95068,6.598,,,
6386.04248,7.598,,,
6386.13379,6.598,,,
6386.22510,6.598,,,
6386.31689,6.598,,,
6386.40820,6.598,,,
6386.50000,6.598,,,
6386.59131,6.598,,,
6386.68311,6.598,,,
6386.77441,6.598,,,
6386.86572,7.598,,,
6386.95752,7.598,,,
6387.04883,7.598,,,
6387.14063,6.598,,,
6387.23193,7.598,,,
6387.32373,7.598,,,
6387.41504,6.598,,,
6387.50684,7.598,,,
6387.59814,7.598,,,
6387.68945,6.598,,,
6387.78125,6.598,,,
6387.87256,6.598,,,
6387.96436,6.598,,,
6388.05566,6.598,,,
6388.14746,6.598,,,
6388.23877,6.598,,,
6388.33008,7.598,,,
6388.42188,7.598,,,
6388.51318,6.598,,,
6388.60498,6.598,,,
6388.69629,6.598,,,
6388.78809,7.598,,,
6388.87939,6.598,,,
6388.97070,6.598,,,
6389.06250,6.598,,,
6389.15381,6.598,,,
6389.24561,6.598,,,
6389.33691,6.598,,,
6389.42871,6.598,,,
6389.52002,6.598,,,
6389.61182,6.598,,,
6389.70313,6.598,,,
6389.79443,7.598,,,
6389.88623,6.598,,,
6389.97754,6.598,,,
6390.06934,6.598,,,
6390.16064,6.598,,,
6390.25244,6.598,,,
6390.34375,6.598,,,
6390.43506,6.598,,,
6390.52686,6.598,,,
6390.61816,6.598,,,
6390.70996,6.598,,,
6390.80127,6.598,,,
6390.89307,7.598,,,
6390.98438,6.598,,,
6391.07568,6.598,,,
6391.16748,6.598,,,
6391.25879,7.598,,,
6391.35059,6.598,,,
6391.44189,6.598,,,
6391.53369,6.598,,,
6391.62500,6.598,,,
6391.71631,6.598,,,
6391.80811,6.598,,,
6391.89941,6.598,,,
6391.99121,6.598,,,
6392.08252,6.598,,,
6392.17432,6.598,,,
6392.26563,6.598,,,
6392.35742,6.598,,,
6392.44873,6.598,,,
6392.54004,6.598,,,
6392.63184,6.598,,,
6392.72314,7.598,,,
6392.81494,6.598,,,
6392.90625,6.598,,,
6392.99805,6.598,,,
6393.08936,6.598,,,
6393.18066,6.598,,,
6393.27246,6.598,,,
6393.36377,6.598,,,
6393.45557,6.598,,,
6393.54688,6.598,,,
6393.63867,6.598,,,
6393.72998,6.598,,,
6393.82129,6.598,,,
6393.91309,6.598,,,
6394.00439,6.598,,,
6394.09619,6.598,,,
6394.18750,6.598,,,
6394.27930,6.598,,,
6394.37061,6.598,,,
6394.46240,6.598,,,
6394.55371,6.598,,,
6394.64502,6.598,,,
6394.73682,6.598,,,
6394.82813,6.598,,,
6394.91992,6.598,,,
6395.01123,6.598,,,
6395.10303,6.598,,,
6395.19434,6.598,,,
6395.28564,5.598,,,
6395.37744,5.598,,,
6395.46875,5.598,,,
6395.56055,6.598,,,
6395.65186,5.598,,,
6395.74365,6.598,,,
6395.83496,6.598,,,
6395.92627,6.598,,,
6396.01807,6.598,,,
6396.10938,6.598,,,
6396.20117,6.598,,,
6396.29248,6.598,,,
6396.38428,5.598,,,
6396.47559,5.598,,,
6396.56738,5.598,,,
6396.65869,6.598,,,
6396.75000,5.598,,,
6396.84180,6.598,,,
6396.93311,5.598,,,
6397.02490,6.598,,,
6397.11621,6.598,,,
6397.20801,6.598,,,
6397.29932,6.598,,,
6397.39063,5.598,,,
6397.48242,5.598,,,
6397.57373,5.598,,,
6397.66553,6.598,,,
6397.75684,6.598,,,
6397.84863,5.598,,,
6397.93994,6.598,,,
6398.03125,6.598,,,
6398.12305,5.598,,,
6398.21436,5.598,,,
6398.30615,6.598,,,
6398.39746,5.598,,,
6398.48926,5.598,,,
6398.58057,6.598,,,
6398.67236,6.598,,,
6398.76367,5.598,,,
6398.85498,5.598,,,
6398.94678,6.598,,,
6399.03809,6.598,,,
6399.12988,5.598,,,
6399.22119,6.598,,,
6399.31299,5.598,,,
6399.40430,5.598,,,
6399.49561,6.598,,,
6399.58740,5.598,,,
6399.67871,5.598,,,
6399.77051,5.598,,,
6399.86182,5.598,,,
6399.95361,5.598,,,
6400.04492,5.598,,,
6400.13623,5.598,,,
6400.22803,5.598,,,
6400.31934,5.598,,,
6400.41113,6.598,,,
6400.50244,5.598,,,
6400.59424,5.598,,,
6400.68555,5.598,,,
6400.77734,6.598,,,
6400.86865,5.598,,,
6400.95996,5.598,,,
6401.05176,5.598,,,
6401.14307,5.598,,,
6401.23486,5.598,,,
6401.32617,5.598,,,
6401.41797,5.598,,,
6401.50928,6.598,,,
6401.60059,5.598,,,
6401.69238,5.598,,,
6401.78369,5.598,,,
6401.87549,5.598,,,
6401.96680,5.598,,,
6402.05859,5.598,,,
6402.14990,5.598,,,
6402.24121,5.598,,,
6402.33301,5.598,,,
6402.42432,5.598,,,
6402.51611,5.598,,,
6402.60742,5.598,,,
6402.69922,5.598,,,
6402.79053,5.598,,,
6402.88232,6.598,,,
6402.97363,6.598,,,
6403.06494,5.598,,,
6403.15674,5.598,,,
6403.24805,5.598,,,
6403.33984,4.598,,,
6403.43115,5.598,,,
6403.52295,5.598,,,
6403.61426,5.598,,,
6403.70557,5.598,,,
6403.79736,5.598,,,
6403.88867,5.598,,,
6403.98047,5.598,,,
6404.07178,5.598,,,
6404.16357,5.598,,,
6404.25488,5.598,,,
6404.34619,5.598,,,
6404.43799,6.598,,,
6404.52930,5.598,,,
6404.62109,5.598,,,
6404.71240,5.598,,,
6404.80420,5.598,,,
6404.89551,5.598,,,
6404.98682,5.598,,,
6405.07861,5.598,,,
6405.16992,5.598,,,
6405.26172,5.598,,,
6405.35303,5.598,,,
6405.44482,5.598,,,
6405.53613,5.598,,,
6405.62793,5.598,,,
6405.71924,4.598,,,
6405.81055,5.598,,,
6405.90234,6.598,,,
6405.99365,5.598,,,
6406.08545,4.598,,,
6406.17676,4.598,,,
6406.26855,5.598,,,
6406.35986,5.598,,,
6406.45117,5.598,,,
6406.54297,5.598,,,
6406.63428,5.598,,,
6406.72607,5.598,,,
6406.81738,5.598,,,
6406.90918,6.598,,,
6407.00049,4.598,,,
6407.09180,5.598,,,
6407.18359,5.598,,,
6407.27490,5.598,,,
6407.36670,6.598,,,
6407.45801,5.598,,,
6407.54980,5.598,,,
6407.64111,5.598,,,
6407.73291,5.598,,,
6407.82422,5.598,,,
6407.91553,5.598,,,
6408.00732,5.598,,,
6408.09863,5.598,,,
6408.19043,4.598,,,
6408.28174,5.598,,,
6408.37354,4.598,,,
6408.46484,5.598,,,
6408.55615,4.598,,,
6408.64795,5.598,,,
6408.73926,4.598,,,
6408.83105,5.598,,,
6408.92236,5.598,,,
6409.01416,5.598,,,
6409.10547,5.598,,,
6409.19678,5.598,,,
6409.28857,5.598,,,
6409.37988,5.598,,,
6409.47168,5.598,,,
6409.56299,5.598,,,
6409.65479,5.598,,,
6409.74609,5.598,,,
6409.83789,5.598,,,
6409.92920,5.598,,,
6410.02051,5.598,,,
6410.11230,5.598,,,
6410.20361,5.598,,,
6410.29541,5.598,,,
6410.38672,5.598,,,
6410.47852,5.598,,,
6410.56982,5.598,,,
6410.66113,4.598,,,
6410.75293,4.598,,,
6410.84424,5.598,,,
6410.93604,5.598,,,
6411.02734,5.598,,,
6411.11914,5.598,,,
6411.21045,5.598,,,
6411.30176,4.598,,,
6411.39355,4.598,,,
6411.48486,4.598,,,
6411.57666,4.598,,,
6411.66797,4.598,,,
6411.75977,5.598,,,
6411.85107,5.598,,,
6411.94287,4.598,,,
6412.03418,5.598,,,
6412.12549,4.598,,,
6412.21729,4.598,,,
6412.30859,5.598,,,
6412.40039,5.598,,,
6412.49170,5.598,,,
6412.58350,5.598,,,
6412.67480,5.598,,,
6412.76611,5.598,,,
6412.85791,4.598,,,
6412.94922,5.598,,,
6413.04102,5.598,,,
6413.13232,4.598,,,
6413.22412,5.598,,,
6413.31543,5.598,,,
6413.40674,5.598,,,
6413.49854,4.598,,,
6413.58984,4.598,,,
6413.68164,5.598,,,
6413.77295,4.598,,,
6413.86475,5.598,,,
6413.95605,5.598,,,
6414.04785,5.598,,,
6414.13916,5.598,,,
6414.23047,4.598,,,
6414.32227,5.598,,,
6414.41357,5.598,,,
6414.50537,5.598,,,
6414.59668,5.598,,,
6414.68848,5.598,,,
6414.77979,5.598,,,
6414.87109,5.598,,,
6414.96289,4.598,,,
6415.05420,5.598,,,
6415.14600,5.598,,,
6415.23730,5.598,,,
6415.32910,4.598,,,
6415.42041,5.598,,,
6415.51172,5.598,,,
6415.60352,4.598,,,
6415.69482,5.598,,,
6415.78662,5.598,,,
6415.87793,4.598,,,
6415.96973,4.598,,,
6416.06104,5.598,,,
6416.15234,5.598,,,
6416.24414,5.598,,,
6416.33545,5.598,,,
6416.42725,4.598,,,
6416.51855,4.598,,,
6416.61035,4.598,,,
6416.70166,5.598,,,
6416.79346,5.598,,,
6416.88477,4.598,,,
6416.97607,5.598,,,
6417.06787,4.598,,,
6417.15918,4.598,,,
6417.25098,4.598,,,
6417.34229,5.598,,,
6417.43408,4.598,,,
6417.52539,5.598,,,
6417.61670,5.598,,,
6417.70850,4.598,,,
6417.79980,4.598,,,
6417.89160,4.598,,,
6417.98291,5.598,,,
6418.07471,5.598,,,
6418.16602,5.598,,,
6418.25732,5.598,,,
6418.34912,4.598,,,
6418.44043,5.598,,,
6418.53223,4.598,,,
6418.62354,5.598,,,
6418.71533,5.598,,,
6418.80664,5.598,,,
6418.89844,5.598,,,
6418.98975,5.598,,,
6419.08105,5.598,,,
6419.17285,5.598,,,
6419.26416,4.598,,,
6419.35596,5.598,,,
6419.44727,5.598,,,
6419.53906,4.598,,,
6419.63037,5.598,,,
6419.72168,4.598,,,
6419.81348,5.598,,,
6419.90479,3.598,,,
6419.99658,4.598,,,
6420.08789,4.598,,,
6420.17969,5.598,,,
6420.27100,4.598,,,
6420.36230,4.598,,,
6420.45410,4.598,,,
6420.54541,5.598,,,
6420.63721,4.598,,,
6420.72852,5.598,,,
6420.82031,5.598,,,
6420.91162,5.598,,,
6421.00342,5.598,,,
6421.09473,4.598,,,
6421.18604,4.598,,,
6421.27783,5.598,,,
6421.36914,4.598,,,
6421.46094,4.598,,,
6421.55225,4.598,,,
6421.64404,5.598,,,
6421.73535,4.598,,,
6421.82666,5.598,,,
6421.91846,4.598,,,
6422.00977,5.598,,,
6422.10156,4.598,,,
6422.19287,4.598,,,
6422.28467,4.598,,,
6422.37598,4.598,,,
6422.46729,5.598,,,
6422.55908,5.598,,,
6422.65039,4.598,,,
6422.74219,5.598,,,
6422.83350,4.598,,,
6422.92529,4.598,,,
6423.01660,4.598,,,
6423.10840,4.598,,,
6423.19971,4.598,,,
6423.29102,4.598,,,
6423.38281,4.598,,,
6423.47412,5.598,,,
6423.56592,5.598,,,
6423.65723,4.598,,,
6423.74902,5.598,,,
6423.84033,4.598,,,
6423.93164,4.598,,,
6424.02344,4.598,,,
6424.11475,4.598,,,
6424.20654,4.598,,,
6424.29785,4.598,,,
6424.38965,4.598,,,
6424.48096,4.598,,,
6424.57227,4.598,,,
6424.66406,4.598,,,
6424.75537,4.598,,,
6424.84717,4.598,,,
6424.93848,5.598,,,
6425.03027,4.598,,,
6425.12158,4.598,,,
6425.21338,4.598,,,
6425.30469,4.598,,,
6425.39600,4.598,,,
6425.48779,4.598,,,
6425.57910,4.598,,,
6425.67090,4.598,,,
6425.76221,4.598,,,
6425.85400,5.598,,,
6425.94531,4.598,,,
6426.03662,4.598,,,
6426.12842,4.598,,,
6426.21973,4.598,,,
6426.31152,4.598,,,
6426.40283,5.598,,,
6426.49463,4.598,,,
6426.58594,4.598,,,
6426.67725,4.598,,,
6426.76904,4.598,,,
6426.86035,4.598,,,
6426.95215,4.598,,,
6427.04346,4.598,,,
6427.13525,4.598,,,
6427.22656,4.598,,,
6427.31836,4.598,,,
6427.40967,4.598,,,
6427.50098,3.598,,,
6427.59277,4.598,,,
6427.68408,4.598,,,
6427.77588,4.598,,,
6427.86719,4.598,,,
6427.95898,4.598,,,
6428.05029,4.598,,,
6428.14160,4.598,,,
6428.23340,4.598,,,
6428.32471,4.598,,,
6428.41650,4.598,,,
6428.50781,4.598,,,
6428.59961,4.598,,,
6428.69092,4.598,,,
6428.78223,4.598,,,
6428.87402,4.598,,,
6428.96533,4.598,,,
6429.05713,4.598,,,
6429.14844,4.598,,,
6429.24023,4.598,,,
6429.33154,5.598,,,
6429.42285,4.598,,,
6429.51465,4.598,,,
6429.60596,4.598,,,
6429.69775,4.598,,,
6429.78906,4.598,,,
6429.88086,5.598,,,
6429.97217,4.598,,,
6430.06396,4.598,,,
6430.15527,5.598,,,
6430.24658,5.598,,,
6430.33838,5.598,,,
6430.42969,5.598,,,
6430.52148,5.598,,,
6430.61279,5.598,,,
6430.70459,5.598,,,
6430.79590,5.598,,,
6430.88721,5.598,,,
6430.97900,4.598,,,
6431.07031,4.598,,,
6431.16211,4.598,,,
6431.25342,4.598,,,
6431.34521,4.598,,,
6431.43652,4.598,,,
6431.52783,4.598,,,
6431.61963,4.598,,,
6431.71094,5.598,,,
6431.80273,5.598,,,
6431.89404,4.598,,,
6431.98584,5.598,,,
6432.07715,5.598,,,
6432.16895,5.598,,,
6432.26025,5.598,,,
6432.35156,5.598,,,
6432.44336,5.598,,,
6432.53467,4.598,,,
6432.62646,5.598,,,
6432.71777,5.598,,,
6432.80957,4.598,,,
6432.90088,5.598,,,
6432.99219,5.598,,,
6433.08398,4.598,,,
6433.17529,4.598,,,
6433.26709,4.598,,,
6433.35840,4.598,,,
6433.45020,4.598,,,
6433.54150,4.598,,,
6433.63281,4.598,,,
6433.72461,4.598,,,
6433.81592,4.598,,,
6433.90771,4.598,,,
6433.99902,4.598,,,
6434.09082,4.598,,,
6434.18213,4.598,,,
6434.27393,4.598,,,
6434.36523,4.598,,,
6434.45654,3.598,,,
6434.54834,4.598,,,
6434.63965,3.598,,,
6434.73145,4.598,,,
6434.82275,4.598,,,
6434.91455,4.598,,,
6435.00586,4.598,,,
6435.09717,4.598,,,
6435.18896,4.598,,,
6435.28027,3.598,,,
6435.37207,4.598,,,
6435.46338,3.598,,,
6435.55518,4.598,,,
6435.64648,4.598,,,
6435.73779,3.598,,,
6435.82959,4.598,,,
6435.92090,4.598,,,
6436.01270,4.598,,,
6436.10400,4.598,,,
6436.19580,4.598,,,
6436.28711,4.598,,,
6436.37891,4.598,,,
6436.47021,4.598,,,
6436.56152,4.598,,,
6436.65332,4.598,,,
6436.74463,4.598,,,
6436.83643,4.598,,,
6436.92773,4.598,,,
6437.01953,4.598,,,
6437.11084,3.598,,,
6437.20215,4.598,,,
6437.29395,4.598,,,
6437.38525,4.598,,,
6437.47705,4.598,,,
6437.56836,4.598,,,
6437.66016,4.598,,,
6437.75146,4.598,,,
6437.84277,4.598,,,
6437.93457,3.598,,,
6438.02588,4.598,,,
6438.11768,5.598,,,
6438.20898,4.598,,,
6438.30078,4.598,,,
6438.39209,4.598,,,
6438.48389,4.598,,,
6438.57520,4.598,,,
6438.66650,4.598,,,
6438.75830,5.598,,,
6438.84961,4.598,,,
6438.94141,4.598,,,
6439.03271,4.598,,,
6439.12451,4.598,,,
6439.21582,4.598,,,
6439.30713,4.598,,,
6439.39893,4.598,,,
6439.49023,4.598,,,
6439.58203,4.598,,,
6439.67334,4.598,,,
6439.76514,4.598,,,
6439.85645,4.598,,,
6439.94775,4.598,,,
6440.03955,4.598,,,
6440.13086,4.598,,,
6440.22266,4.598,,,
6440.31396,4.598,,,
6440.40576,3.598,,,
6440.49707,4.598,,,
6440.58838,4.598,,,
6440.68018,4.598,,,
6440.77148,3.598,,,
6440.86328,3.598,,,
6440.95459,4.598,,,
6441.04639,4.598,,,
6441.13770,3.598,,,
6441.22949,4.598,,,
6441.32080,3.598,,,
6441.41211,4.598,,,
6441.50391,4.598,,,
6441.59521,4.598,,,
6441.68701,3.598,,,
6441.77832,3.598,,,
6441.87012,4.598,,,
6441.96143,3.598,,,
6442.05273,4.598,,,
6442.14453,4.598,,,
6442.23584,4.598,,,
6442.32764,4.598,,,
6442.41895,4.598,,,
6442.51074,4.598,,,
6442.60205,4.598,,,
6442.69336,4.598,,,
6442.78516,4.598,,,
6442.87646,3.598,,,
6442.96826,4.598,,,
6443.05957,4.598,,,
6443.15137,4.598,,,
6443.24268,3.598,,,
6443.33447,4.598,,,
6443.42578,3.598,,,
6443.51709,3.598,,,
6443.60889,3.598,,,
6443.70020,3.598,,,
6443.79199,3.598,,,
6443.88330,3.598,,,
6443.97510,4.598,,,
6444.06641,3.598,,,
6444.15771,4.598,,,
6444.24951,4.598,,,
6444.34082,3.598,,,
6444.43262,3.598,,,
6444.52393,3.598,,,
6444.61572,3.598,,,
6444.70703,3.598,,,
6444.79834,3.598,,,
6444.89014,3.598,,,
6444.98145,3.598,,,
6445.07324,3.598,,,
6445.16455,3.598,,,
6445.25635,3.598,,,
6445.34766,3.598,,,
6445.43945,4.598,,,
6445.53076,4.598,,,
6445.62207,4.598,,,
6445.71387,3.598,,,
6445.80518,4.598,,,
6445.89697,4.598,,,
6445.98828,4.598,,,
6446.08008,3.598,,,
6446.17139,4.598,,,
6446.26270,4.598,,,
6446.35449,4.598,,,
6446.44580,3.598,,,
6446.53760,3.598,,,
6446.62891,3.598,,,
6446.72070,4.598,,,
6446.81201,4.598,,,
6446.90332,4.598,,,
6446.99512,4.598,,,
6447.08643,4.598,,,
6447.17822,4.598,,,
6447.26953,4.598,,,
6447.36133,4.598,,,
6447.45264,4.598,,,
6447.54443,4.598,,,
6447.63574,4.598,,,
6447.72705,4.598,,,
6447.81885,3.598,,,
6447.91016,4.598,,,
6448.00195,3.598,,,
6448.09326,3.598,,,
6448.18506,4.598,,,
6448.27637,4.598,,,
6448.36768,4.598,,,
6448.45947,4.598,,,
6448.55078,4.598,,,
6448.64258,4.598,,,
6448.73389,3.598,,,
6448.82568,4.598,,,
6448.91699,4.598,,,
6449.00830,4.598,,,
6449.10010,4.598,,,
6449.19141,3.598,,,
6449.28320,4.598,,,
6449.37451,4.598,,,
6449.46631,4.598,,,
6449.55762,4.598,,,
6449.64941,4.598,,,
6449.74072,4.598,,,
6449.83203,4.598,,,
6449.92383,4.598,,,
6450.01514,3.598,,,
6450.10693,3.598,,,
6450.19824,4.598,,,
6450.29004,3.598,,,
6450.38135,4.598,,,
6450.47266,4.598,,,
6450.56445,3.598,,,
6450.65576,3.598,,,
6450.74756,4.598,,,
6450.83887,4.598,,,
6450.93066,3.598,,,
6451.02197,4.598,,,
6451.11328,3.598,,,
6451.20508,3.598,,,
6451.29639,4.598,,,
6451.38818,3.598,,,
6451.47949,3.598,,,
6451.57129,3.598,,,
6451.66260,3.598,,,
6451.75439,3.598,,,
6451.84570,3.598,,,
6451.93701,3.598,,,
6452.02881,3.598,,,
6452.12012,3.598,,,
6452.21191,3.598,,,
6452.30322,3.598,,,
6452.39502,4.598,,,
6452.48633,3.598,,,
6452.57764,3.598,,,
6452.66943,3.598,,,
6452.76074,4.598,,,
6452.85254,3.598,,,
6452.94385,3.598,,,
6453.03564,3.598,,,
6453.12695,4.598,,,
6453.21826,3.598,,,
6453.31006,3.598,,,
6453.40137,3.598,,,
6453.49316,3.598,,,
6453.58447,3.598,,,
6453.67627,3.598,,,
6453.76758,3.598,,,
6453.85889,3.598,,,
6453.95068,3.598,,,
6454.04199,3.598,,,
6454.13379,4.598,,,
6454.22510,4.598,,,
6454.31689,3.598,,,
6454.40820,4.598,,,
6454.50000,4.598,,,
6454.59131,3.598,,,
6454.68262,4.598,,,
6454.77441,3.598,,,
6454.86572,4.598,,,
6454.95752,4.598,,,
6455.04883,4.598,,,
6455.14063,3.598,,,
6455.23193,4.598,,,
6455.32324,4.598,,,
6455.41504,3.598,,,
6455.50635,4.598,,,
6455.59814,4.598,,,
6455.68945,4.598,,,
6455.78125,3.598,,,
6455.87256,4.598,,,
6455.96387,4.598,,,
6456.05566,4.598,,,
6456.14697,4.598,,,
6456.23877,4.598,,,
6456.33008,4.598,,,
6456.42188,4.598,,,
6456.51318,4.598,,,
6456.60498,3.598,,,
6456.69629,3.598,,,
6456.78760,3.598,,,
6456.87939,3.598,,,
6456.97070,3.598,,,
6457.06250,3.598,,,
6457.15381,4.598,,,
6457.24561,4.598,,,
6457.33691,4.598,,,
6457.42822,3.598,,,
6457.52002,4.598,,,
6457.61133,4.598,,,
6457.70313,3.598,,,
6457.79443,4.598,,,
6457.88623,3.598,,,
6457.97754,3.598,,,
6458.06885,3.598,,,
6458.16064,3.598,,,
6458.25195,3.598,,,
6458.34375,3.598,,,
6458.43506,4.598,,,
6458.52686,3.598,,,
6458.61816,4.598,,,
6458.70996,4.598,,,
6458.80127,4.598,,,
6458.89258,3.598,,,
6458.98438,4.598,,,
6459.07568,3.598,,,
6459.16748,3.598,,,
6459.25879,4.598,,,
6459.35059,4.598,,,
6459.44189,3.598,,,
6459.53320,3.598,,,
6459.62500,4.598,,,
6459.71631,3.598,,,
6459.80811,3.598,,,
6459.89941,4.598,,,
6459.99121,3.598,,,
6460.08252,4.598,,,
6460.17383,3.598,,,
6460.26563,4.598,,,
6460.35693,4.598,,,
6460.44873,3.598,,,
6460.54004,4.598,,,
6460.63184,3.598,,,
6460.72314,4.598,,,
6460.81494,3.598,,,
6460.90625,4.598,,,
6460.99756,3.598,,,
6461.08936,3.598,,,
6461.18066,4.598,,,
6461.27246,4.598,,,
6461.36377,3.598,,,
6461.45557,3.598,,,
6461.54688,4.598,,,
6461.63818,3.598,,,
6461.72998,3.598,,,
6461.82129,3.598,,,
6461.91309,3.598,,,
6462.00439,3.598,,,
6462.09619,3.598,,,
6462.18750,3.598,,,
6462.27881,3.598,,,
6462.37061,3.598,,,
6462.46191,3.598,,,
6462.55371,3.598,,,
6462.64502,3.598,,,
6462.73682,3.598,,,
6462.82813,4.598,,,
6462.91992,4.598,,,
6463.01123,4.598,,,
6463.10254,4.598,,,
6463.19434,4.598,,,
6463.28564,4.598,,,
6463.37744,4.598,,,
6463.46875,4.598,,,
6463.56055,4.598,,,
6463.65186,4.598,,,
6463.74316,4.598,,,
6463.83496,3.598,,,
6463.92627,4.598,,,
6464.01807,3.598,,,
6464.10938,3.598,,,
6464.20117,3.598,,,
6464.29248,3.598,,,
6464.38379,3.598,,,
6464.47559,4.598,,,
6464.56689,4.598,,,
6464.65869,3.598,,,
6464.75000,3.598,,,
6464.84180,3.598,,,
6464.93311,3.598,,,
6465.02490,3.598,,,
6465.11621,4.598,,,
6465.20752,4.598,,,
6465.29932,3.598,,,
6465.39063,3.598,,,
6465.48242,4.598,,,
6465.57373,4.598,,,
6465.66553,3.598,,,
6465.75684,4.598,,,
6465.84814,4.598,,,
6465.93994,4.598,,,
6466.03125,3.598,,,
6466.12305,3.598,,,
6466.21436,4.598,,,
6466.30615,4.598,,,
6466.39746,4.598,,,
6466.48877,3.598,,,
6466.58057,3.598,,,
6466.67188,4.598,,,
6466.76367,3.598,,,
6466.85498,3.598,,,
6466.94678,4.598,,,
6467.03809,3.598,,,
6467.12939,3.598,,,
6467.22119,3.598,,,
6467.31250,3.598,,,
6467.40430,4.598,,,
6467.49561,3.598,,,
6467.58740,4.598,,,
6467.67871,3.598,,,
6467.77051,4.598,,,
6467.86182,4.598,,,
6467.95313,4.598,,,
6468.04492,3.598,,,
6468.13623,4.598,,,
6468.22803,3.598,,,
6468.31934,4.598,,,
6468.41113,4.598,,,
6468.50244,3.598,,,
6468.59375,4.598,,,
6468.68555,3.598,,,
6468.77686,4.598,,,
6468.86865,5.598,,,
6468.95996,4.598,,,
6469.05176,4.598,,,
6469.14307,4.598,,,
6469.23438,4.598,,,
6469.32617,4.598,,,
6469.41748,4.598,,,
6469.50928,4.598,,,
6469.60059,4.598,,,
6469.69238,3.598,,,
6469.78369,4.598,,,
6469.87549,3.598,,,
6469.96680,4.598,,,
6470.05811,3.598,,,
6470.14990,3.598,,,
6470.24121,4.598,,,
6470.33301,5.598,,,
6470.42432,4.598,,,
6470.51611,4.598,,,
6470.60742,4.598,,,
6470.69873,4.598,,,
6470.79053,4.598,,,
6470.88184,4.598,,,
6470.97363,4.598,,,
6471.06494,4.598,,,
6471.15674,4.598,,,
6471.24805,4.598,,,
6471.33936,4.598,,,
6471.43115,4.598,,,
6471.52246,3.598,,,
6471.61426,3.598,,,
6471.70557,3.598,,,
6471.79736,4.598,,,
6471.88867,4.598,,,
6471.98047,4.598,,,
6472.07178,3.598,,,
6472.16309,4.598,,,
6472.25488,4.598,,,
6472.34619,4.598,,,
6472.43799,4.598,,,
6472.52930,4.598,,,
6472.62109,4.598,,,
6472.71240,4.598,,,
6472.80371,4.598,,,
6472.89551,4.598,,,
6472.98682,4.598,,,
6473.07861,3.598,,,
6473.16992,4.598,,,
6473.26172,4.598,,,
6473.35303,4.598,,,
6473.44434,4.598,,,
6473.53613,4.598,,,
6473.62744,4.598,,,
6473.71924,4.598,,,
6473.81055,4.598,,,
6473.90234,4.598,,,
6473.99365,4.598,,,
6474.08545,4.598,,,
6474.17676,4.598,,,
6474.26807,4.598,,,
6474.35986,4.598,,,
6474.45117,5.598,,,
6474.54297,4.598,,,
6474.63428,4.598,,,
6474.72607,5.598,,,
6474.81738,4.598,,,
6474.90869,4.598,,,
6475.00049,4.598,,,
6475.09180,4.598,,,
6475.18359,4.598,,,
6475.27490,4.598,,,
6475.36670,4.598,,,
6475.45801,4.598,,,
6475.54932,4.598,,,
6475.64111,3.598,,,
6475.73242,4.598,,,
6475.82422,3.598,,,
6475.91553,4.598,,,
6476.00732,3.598,,,
6476.09863,4.598,,,
6476.19043,4.598,,,
6476.28174,4.598,,,
6476.37305,4.598,,,
6476.46484,4.598,,,
6476.55615,4.598,,,
6476.64795,4.598,,,
6476.73926,4.598,,,
6476.83105,4.598,,,
6476.92236,4.598,,,
6477.01367,3.598,,,
6477.10547,4.598,,,
6477.19678,4.598,,,
6477.28857,4.598,,,
6477.37988,3.598,,,
6477.47168,4.598,,,
6477.56299,3.598,,,
6477.65430,4.598,,,
6477.74609,4.598,,,
6477.83740,4.598,,,
6477.92920,4.598,,,
6478.02051,4.598,,,
6478.11230,4.598,,,
6478.20361,4.598,,,
6478.29492,4.598,,,
6478.38672,4.598,,,
6478.47803,4.598,,,
6478.56982,4.598,,,
6478.66113,4.598,,,
6478.75293,4.598,,,
6478.84424,3.598,,,
6478.93604,4.598,,,
6479.02734,3.598,,,
6479.11865,4.598,,,
6479.21045,4.598,,,
6479.30176,3.598,,,
6479.39355,4.598,,,
6479.48486,4.598,,,
6479.57666,3.598,,,
6479.66797,3.598,,,
6479.75928,3.598,,,
6479.85107,4.598,,,
6479.94238,3.598,,,
6480.03418,3.598,,,
6480.12549,3.598,,,
6480.21729,4.598,,,
6480.30859,3.598,,,
6480.39990,3.598,,,
6480.49170,3.598,,,
6480.58301,3.598,,,
6480.67480,4.598,,,
6480.76611,3.598,,,
6480.85791,3.598,,,
6480.94922,3.598,,,
6481.04102,3.598,,,
6481.13232,4.598,,,
6481.22363,3.598,,,
6481.31543,3.598,,,
6481.40674,4.598,,,
6481.49854,3.598,,,
6481.58984,3.598,,,
6481.68164,4.598,,,
6481.77295,4.598,,,
6481.86426,3.598,,,
6481.95605,4.598,,,
6482.04736,5.598,,,
6482.13916,4.598,,,
6482.23047,4.598,,,
6482.32227,4.598,,,
6482.41357,3.598,,,
6482.50488,3.598,,,
6482.59668,3.598,,,
6482.68799,3.598,,,
6482.77979,4.598,,,
6482.87109,3.598,,,
6482.96289,3.598,,,
6483.05420,3.598,,,
6483.14600,3.598,,,
6483.23730,3.598,,,
6483.32861,3.598,,,
6483.42041,3.598,,,
6483.51172,4.598,,,
6483.60352,4.598,,,
6483.69482,3.598,,,
6483.78662,3.598,,,
6483.87793,3.598,,,
6483.96924,3.598,,,
6484.06104,3.598,,,
6484.15234,4.598,,,
6484.24414,4.598,,,
6484.33545,3.598,,,
6484.42725,3.598,,,
6484.51855,3.598,,,
6484.60986,3.598,,,
6484.70166,3.598,,,
6484.79297,4.598,,,
6484.88477,3.598,,,
6484.97607,4.598,,,
6485.06787,4.598,,,
6485.15918,4.598,,,
6485.25098,3.598,,,
6485.34229,4.598,,,
6485.43359,4.598,,,
6485.52539,3.598,,,
6485.61670,3.598,,,
6485.70850,3.598,,,
6485.79980,3.598,,,
6485.89160,3.598,,,
6485.98291,3.598,,,
6486.07422,3.598,,,
6486.16602,3.598,,,
6486.25732,3.598,,,
6486.34912,3.598,,,
6486.44043,4.598,,,
6486.53223,3.598,,,
6486.62354,4.598,,,
6486.71484,3.598,,,
6486.80664,3.598,,,
6486.89795,3.598,,,
6486.98975,4.598,,,
6487.08105,3.598,,,
6487.17285,4.598,,,
6487.26416,3.598,,,
6487.35596,3.598,,,
6487.44727,4.598,,,
6487.53857,3.598,,,
6487.63037,3.598,,,
6487.72168,3.598,,,
6487.81348,4.598,,,
6487.90479,4.598,,,
6487.99658,4.598,,,
6488.08789,3.598,,,
6488.17920,4.598,,,
6488.27100,3.598,,,
6488.36230,3.598,,,
6488.45410,3.598,,,
6488.54541,3.598,,,
6488.63721,3.598,,,
6488.72852,3.598,,,
6488.81982,3.598,,,
6488.91162,3.598,,,
6489.00293,3.598,,,
6489.09473,3.598,,,
6489.18604,3.598,,,
6489.27783,3.598,,,
6489.36914,4.598,,,
6489.46094,3.598,,,
6489.55225,3.598,,,
6489.64355,3.598,,,
6489.73535,3.598,,,
6489.82666,3.598,,,
6489.91846,4.598,,,
6490.00977,4.598,,,
6490.10156,3.598,,,
6490.19287,3.598,,,
6490.28418,3.598,,,
6490.37598,3.598,,,
6490.46729,3.598,,,
6490.55908,3.598,,,
6490.65039,3.598,,,
6490.74219,3.598,,,
6490.83350,4.598,,,
6490.92480,3.598,,,
6491.01660,3.598,,,
6491.10791,3.598,,,
6491.19971,3.598,,,
6491.29102,3.598,,,
6491.38281,3.598,,,
6491.47412,3.598,,,
6491.56543,3.598,,,
6491.65723,3.598,,,
6491.74854,3.598,,,
6491.84033,3.598,,,
6491.93164,3.598,,,
6492.02344,3.598,,,
6492.11475,3.598,,,
6492.20654,3.598,,,
6492.29785,4.598,,,
6492.38916,3.598,,,
6492.48096,3.598,,,
6492.57227,3.598,,,
6492.66406,3.598,,,
6492.75537,4.598,,,
6492.84717,3.598,,,
6492.93848,3.598,,,
6493.02979,3.598,,,
6493.12158,3.598,,,
6493.21289,3.598,,,
6493.30469,3.598,,,
6493.39600,3.598,,,
6493.48779,3.598,,,
6493.57910,3.598,,,
6493.67041,3.598,,,
6493.76221,3.598,,,
6493.85352,3.598,,,
6493.94531,3.598,,,
6494.03662,3.598,,,
6494.12842,3.598,,,
6494.21973,3.598,,,
6494.31152,3.598,,,
6494.40283,3.598,,,
6494.49414,3.598,,,
6494.58594,3.598,,,
6494.67725,2.598,,,
6494.76904,3.598,,,
6494.86035,3.598,,,
6494.95215,3.598,,,
6495.04346,2.598,,,
6495.13477,2.598,,,
6495.22656,4.598,,,
6495.31787,2.598,,,
6495.40967,3.598,,,
6495.50098,3.598,,,
6495.59277,3.598,,,
6495.68408,3.598,,,
6495.77539,3.598,,,
6495.86719,3.598,,,
6495.95850,3.598,,,
6496.05029,2.598,,,
6496.14160,3.598,,,
6496.23340,2.598,,,
6496.32471,3.598,,,
6496.41650,3.598,,,
6496.50781,3.598,,,
6496.59912,3.598,,,
6496.69092,3.598,,,
6496.78223,3.598,,,
6496.87402,3.598,,,
6496.96533,3.598,,,
6497.05713,3.598,,,
6497.14844,2.598,,,
6497.23975,2.598,,,
6497.33154,3.598,,,
6497.42285,3.598,,,
6497.51465,3.598,,,
6497.60596,3.598,,,
6497.69775,3.598,,,
6497.78906,2.598,,,
6497.88037,2.598,,,
6497.97217,2.598,,,
6498.06348,3.598,,,
6498.15527,3.598,,,
6498.24658,3.598,,,
6498.33838,2.598,,,
6498.42969,2.598,,,
6498.52148,2.598,,,
6498.61279,3.598,,,
6498.70410,2.598,,,
6498.79590,3.598,,,
6498.88721,3.598,,,
6498.97900,2.598,,,
6499.07031,2.598,,,
6499.16211,2.598,,,
6499.25342,2.598,,,
6499.34473,2.598,,,
6499.43652,3.598,,,
6499.52783,3.598,,,
6499.61963,3.598,,,
6499.71094,3.598,,,
6499.80273,3.598,,,
6499.89404,3.598,,,
6499.98535,2.598,,,
6500.07715,2.598,,,
6500.16846,2.598,,,
6500.26025,3.598,,,
6500.35156,2.598,,,
6500.44336,3.598,,,
6500.53467,2.598,,,
6500.62646,2.598,,,
6500.71777,2.598,,,
6500.80908,3.598,,,
6500.90088,2.598,,,
6500.99219,3.598,,,
6501.08398,3.598,,,
6501.17529,2.598,,,
6501.26709,3.598,,,
6501.35840,3.598,,,
6501.44971,2.598,,,
6501.54150,2.598,,,
6501.63281,3.598,,,
6501.72461,3.598,,,
6501.81592,2.598,,,
6501.90771,2.598,,,
6501.99902,2.598,,,
6502.09033,2.598,,,
6502.18213,2.598,,,
6502.27344,2.598,,,
6502.36523,2.598,,,
6502.45654,2.598,,,
6502.54834,2.598,,,
6502.63965,2.598,,,
6502.73145,2.598,,,
6502.82275,3.598,,,
6502.91406,2.598,,,
6503.00586,2.598,,,
6503.09717,3.598,,,
6503.18896,3.598,,,
6503.28027,3.598,,,
6503.37207,2.598,,,
6503.46338,2.598,,,
6503.55469,2.598,,,
6503.64648,2.598,,,
6503.73779,2.598,,,
6503.82959,2.598,,,
6503.92090,2.598,,,
6504.01270,2.598,,,
6504.10400,2.598,,,
6504.19531,2.598,,,
6504.28711,2.598,,,
6504.37842,2.598,,,
6504.47021,3.598,,,
6504.56152,2.598,,,
6504.65332,2.598,,,
6504.74463,2.598,,,
6504.83594,2.598,,,
6504.92773,1.598,,,
6505.01904,2.598,,,
6505.11084,2.598,,,
6505.20215,1.598,,,
6505.29395,2.598,,,
6505.38525,1.598,,,
6505.47705,2.598,,,
6505.56836,2.598,,,
6505.65967,2.598,,,
6505.75146,2.598,,,
6505.84277,2.598,,,
6505.93457,2.598,,,
6506.02588,2.598,,,
6506.11768,2.598,,,
6506.20898,2.598,,,
6506.30029,2.598,,,
6506.39209,2.598,,,
6506.48340,2.598,,,
6506.57520,2.598,,,
6506.66650,2.598,,,
6506.75830,2.598,,,
6506.84961,2.598,,,
6506.94092,2.598,,,
6507.03271,2.598,,,
6507.12402,2.598,,,
6507.21582,2.598,,,
6507.30713,2.598,,,
6507.39893,2.598,,,
6507.49023,2.598,,,
6507.58203,2.598,,,
6507.67334,2.598,,,
6507.76465,2.598,,,
6507.85645,2.598,,,
6507.94775,2.598,,,
6508.03955,2.598,,,
6508.13086,1.598,,,
6508.22266,2.598,,,
6508.31396,1.598,,,
6508.40527,2.598,,,
6508.49707,1.598,,,
6508.58838,2.598,,,
6508.68018,2.598,,,
6508.77148,2.598,,,
6508.86328,1.598,,,
6508.95459,2.598,,,
6509.04590,2.598,,,
6509.13770,1.598,,,
6509.22900,1.598,,,
6509.32080,2.598,,,
6509.41211,2.598,,,
6509.50391,1.598,,,
6509.59521,2.598,,,
6509.68701,2.598,,,
6509.77832,2.598,,,
6509.86963,2.598,,,
6509.96143,2.598,,,
6510.05273,2.598,,,
6510.14453,1.598,,,
6510.23584,1.598,,,
6510.32764,2.598,,,
6510.41895,1.598,,,
6510.51025,2.598,,,
6510.60205,2.598,,,
6510.69336,1.598,,,
6510.78516,1.598,,,
6510.87646,2.598,,,
6510.96826,1.598,,,
6511.05957,1.598,,,
6511.15088,2.598,,,
6511.24268,1.598,,,
6511.33398,2.598,,,
6511.42578,2.598,,,
6511.51709,2.598,,,
6511.60889,2.598,,,
6511.70020,2.598,,,
6511.79199,2.598,,,
6511.88330,2.598,,,
6511.97461,2.598,,,
6512.06641,2.598,,,
6512.15771,2.598,,,
6512.24951,2.598,,,
6512.34082,2.598,,,
6512.43262,2.598,,,
6512.52393,1.598,,,
6512.61523,1.598,,,
6512.70703,2.598,,,
6512.79834,3.598,,,
6512.89014,2.598,,,
6512.98145,2.598,,,
6513.07324,2.598,,,
6513.16455,2.598,,,
6513.25586,2.598,,,
6513.34766,2.598,,,
6513.43896,2.598,,,
6513.53076,1.598,,,
6513.62207,1.598,,,
6513.71387,2.598,,,
6513.80518,1.598,,,
6513.89697,1.598,,,
6513.98828,1.598,,,
6514.07959,1.598,,,
6514.17139,1.598,,,
6514.26270,1.598,,,
6514.35449,1.598,,,
6514.44580,1.598,,,
6514.53760,1.598,,,
6514.62891,1.598,,,
6514.72021,2.598,,,
6514.81201,2.598,,,
6514.90332,2.598,,,
6514.99512,1.598,,,
6515.08643,2.598,,,
6515.17822,2.598,,,
6515.26953,2.598,,,
6515.36084,1.598,,,
6515.45264,2.598,,,
6515.54395,2.598,,,
6515.63574,2.598,,,
6515.72705,2.598,,,
6515.81885,1.598,,,
6515.91016,2.598,,,
6516.00146,2.598,,,
6516.09326,1.598,,,
6516.18457,1.598,,,
6516.27637,1.598,,,
6516.36768,1.598,,,
6516.45947,1.598,,,
6516.55078,1.598,,,
6516.64258,0.598,,,
6516.73389,1.598,,,
6516.82520,1.598,,,
6516.91699,1.598,,,
6517.00830,1.598,,,
6517.10010,1.598,,,
6517.19141,1.598,,,
6517.28320,1.598,,,
6517.37451,1.598,,,
6517.46582,1.598,,,
6517.55762,1.598,,,
6517.64893,1.598,,,
6517.74072,1.598,,,
6517.83203,1.598,,,
6517.92383,1.598,,,
6518.01514,1.598,,,
6518.10645,1.598,,,
6518.19824,1.598,,,
6518.28955,1.598,,,
6518.38135,1.598,,,
6518.47266,1.598,,,
6518.56445,1.598,,,
6518.65576,1.598,,,
6518.74756,1.598,,,
6518.83887,1.598,,,
6518.93018,1.598,,,
6519.02197,1.598,,,
6519.11328,1.598,,,
6519.20508,1.598,,,
6519.29639,1.598,,,
6519.38818,1.598,,,
6519.47949,1.598,,,
6519.57080,1.598,,,
6519.66260,0.598,,,
6519.75391,1.598,,,
6519.84570,1.598,,,
6519.93701,1.598,,,
6520.02881,1.598,,,
6520.12012,1.598,,,
6520.21143,1.598,,,
6520.30322,1.598,,,
6520.39453,1.598,,,
6520.48633,0.598,,,
6520.57764,1.598,,,
6520.66943,1.598,,,
6520.76074,0.598,,,
6520.85254,1.598,,,
6520.94385,0.598,,,
6521.03516,1.598,,,
6521.12695,0.598,,,
6521.21826,1.598,,,
6521.31006,1.598,,,
6521.40137,0.598,,,
6521.49316,1.598,,,
6521.58447,1.598,,,
6521.67578,1.598,,,
6521.76758,1.598,,,
6521.85889,1.598,,,
6521.95068,1.598,,,
6522.04199,1.598,,,
6522.13379,1.598,,,
6522.22510,1.598,,,
6522.31641,1.598,,,
6522.40820,1.598,,,
6522.49951,1.598,,,
6522.59131,0.598,,,
6522.68262,0.598,,,
6522.77441,0.598,,,
6522.86572,0.598,,,
6522.95752,0.598,,,
6523.04883,1.598,,,
6523.14014,1.598,,,
6523.23193,0.598,,,
6523.32324,0.598,,,
6523.41504,0.598,,,
6523.50635,0.598,,,
6523.59814,0.598,,,
6523.68945,0.598,,,
6523.78076,1.598,,,
6523.87256,0.598,,,
6523.96387,0.598,,,
6524.05566,0.598,,,
6524.14697,0.598,,,
6524.23877,0.598,,,
6524.33008,0.598,,,
6524.42139,0.598,,,
6524.51318,1.598,,,
6524.60449,1.598,,,
6524.69629,1.598,,,
6524.78760,0.598,,,
6524.87939,0.598,,,
6524.97070,0.598,,,
6525.06250,0.598,,,
6525.15381,0.598,,,
6525.24512,0.598,,,
6525.33691,0.598,,,
6525.42822,0.598,,,
6525.52002,0.598,,,
6525.61133,0.598,,,
6525.70313,0.598,,,
6525.79443,0.598,,,
6525.88574,0.598,,,
6525.97754,1.598,,,
6526.06885,0.598,,,
6526.16064,1.598,,,
6526.25195,0.598,,,
6526.34375,0.598,,,
6526.43506,0.598,,,
6526.52637,0.598,,,
6526.61816,0.598,,,
6526.70947,0.598,,,
6526.80127,0.598,,,
6526.89258,0.598,,,
6526.98438,-0.402,,,
6527.07568,0.598,,,
6527.16748,0.598,,,
6527.25879,0.598,,,
6527.35010,0.598,,,
6527.44189,0.598,,,
6527.53320,0.598,,,
6527.62500,0.598,,,
6527.71631,0.598,,,
6527.80811,0.598,,,
6527.89941,0.598,,,
6527.99072,0.598,,,
6528.08252,0.598,,,
6528.17383,0.598,,,
6528.26563,0.598,,,
6528.35693,0.598,,,
6528.44873,-0.402,,,
6528.54004,0.598,,,
6528.63135,0.598,,,
6528.72314,-0.402,,,
6528.81445,0.598,,,
6528.90625,1.598,,,
6528.99756,0.598,,,
6529.08936,0.598,,,
6529.18066,0.598,,,
6529.27197,0.598,,,
6529.36377,0.598,,,
6529.45508,0.598,,,
6529.54688,0.598,,,
6529.63818,-0.402,,,
6529.72998,0.598,,,
6529.82129,0.598,,,
6529.91309,0.598,,,
6530.00439,0.598,,,
6530.09570,0.598,,,
6530.18750,0.598,,,
6530.27881,0.598,,,
6530.37061,1.598,,,
6530.46191,0.598,,,
6530.55371,0.598,,,
6530.64502,0.598,,,
6530.73633,0.598,,,
6530.82813,0.598,,,
6530.91943,0.598,,,
6531.01123,0.598,,,
6531.10254,0.598,,,
6531.19434,0.598,,,
6531.28564,0.598,,,
6531.37695,0.598,,,
6531.46875,-0.402,,,
6531.56006,-0.402,,,
6531.65186,-0.402,,,
6531.74316,0.598,,,
6531.83496,0.598,,,
6531.92627,0.598,,,
6532.01807,0.598,,,
6532.10938,0.598,,,
6532.20068,0.598,,,
6532.29248,0.598,,,
6532.38379,0.598,,,
6532.47559,1.598,,,
6532.56689,0.598,,,
6532.65869,0.598,,,
6532.75000,0.598,,,
6532.84131,0.598,,,
6532.93311,0.598,,,
6533.02441,0.598,,,
6533.11621,0.598,,,
6533.20752,0.598,,,
6533.29932,1.598,,,
6533.39063,0.598,,,
6533.48193,1.598,,,
6533.57373,0.598,,,
6533.66504,1.598,,,
6533.75684,1.598,,,
6533.84814,0.598,,,
6533.93994,0.598,,,
6534.03125,-0.402,,,
6534.12305,0.598,,,
6534.21436,0.598,,,
6534.30566,-0.402,,,
6534.39746,0.598,,,
6534.48877,-0.402,,,
6534.58057,-0.402,,,
6534.67188,-0.402,,,
6534.76367,0.598,,,
6534.85498,0.598,,,
6534.94629,-0.402,,,
6535.03809,0.598,,,
6535.12939,0.598,,,
6535.22119,0.598,,,
6535.31250,-0.402,,,
6535.40430,0.598,,,
6535.49561,0.598,,,
6535.58691,-0.402,,,
6535.67871,0.598,,,
6535.77002,0.598,,,
6535.86182,0.598,,,
6535.95313,0.598,,,
6536.04492,0.598,,,
6536.13623,-0.402,,,
6536.22803,0.598,,,
6536.31934,0.598,,,
6536.41064,0.598,,,
6536.50244,0.598,,,
6536.59375,0.598,,,
6536.68555,0.598,,,
6536.77686,-0.402,,,
6536.86865,0.598,,,
6536.95996,0.598,,,
6537.05127,0.598,,,
6537.14307,-0.402,,,
6537.23438,0.598,,,
6537.32617,-0.402,,,
6537.41748,-0.402,,,
6537.50928,0.598,,,
6537.60059,-0.402,,,
6537.69189,0.598,,,
6537.78369,0.598,,,
6537.87500,0.598,,,
6537.96680,0.598,,,
6538.05811,0.598,,,
6538.14990,0.598,,,
6538.24121,0.598,,,
6538.33301,0.598,,,
6538.42432,0.598,,,
6538.51563,0.598,,,
6538.60742,0.598,,,
6538.69873,-0.402,,,
6538.79053,0.598,,,
6538.88184,-0.402,,,
6538.97363,0.598,,,
6539.06494,0.598,,,
6539.15625,0.598,,,
6539.24805,-0.402,,,
6539.33936,-0.402,,,
6539.43115,-0.402,,,
6539.52246,-0.402,,,
6539.61426,0.598,,,
6539.70557,0.598,,,
6539.79688,0.598,,,
6539.88867,-0.402,,,
6539.97998,0.598,,,
6540.07178,-0.402,,,
6540.16309,-0.402,,,
6540.25488,0.598,,,
6540.34619,0.598,,,
6540.43750,-0.402,,,
6540.52930,-0.402,,,
6540.62061,0.598,,,
6540.71240,0.598,,,
6540.80371,-0.402,,,
6540.89551,-0.402,,,
6540.98682,0.598,,,
6541.07861,-0.402,,,
6541.16992,-0.402,,,
6541.26123,0.598,,,
6541.35303,0.598,,,
6541.44434,-0.402,,,
6541.53613,-0.402,,,
6541.62744,-0.402,,,
6541.71924,-0.402,,,
6541.81055,0.598,,,
6541.90186,-0.402,,,
6541.99365,0.598,,,
6542.08496,0.598,,,
6542.17676,-0.402,,,
6542.26807,0.598,,,
6542.35986,-0.402,,,
6542.45117,-0.402,,,
6542.54248,-0.402,,,
6542.63428,-0.402,,,
6542.72559,0.598,,,
6542.81738,-0.402,,,
6542.90869,-0.402,,,
6543.00049,-0.402,,,
6543.09180,-0.402,,,
6543.18359,-0.402,,,
6543.27490,-0.402,,,
6543.36621,-0.402,,,
6543.45801,-0.402,,,
6543.54932,-0.402,,,
6543.64111,-0.402,,,
6543.73242,-0.402,,,
6543.82422,-0.402,,,
6543.91553,-0.402,,,
6544.00684,0.598,,,
6544.09863,0.598,,,
6544.18994,-0.402,,,
6544.28174,-0.402,,,
6544.37305,-0.402,,,
6544.46484,-0.402,,,
6544.55615,-0.402,,,
6544.64746,-0.402,,,
6544.73926,-0.402,,,
6544.83057,-0.402,,,
6544.92236,-0.402,,,
6545.01367,0.598,,,
6545.10547,-0.402,,,
6545.19678,-0.402,,,
6545.28857,-0.402,,,
6545.37988,-0.402,,,
6545.47119,0.598,,,
6545.56299,-0.402,,,
6545.65430,0.598,,,
6545.74609,-0.402,,,
6545.83740,0.598,,,
6545.92920,-0.402,,,
6546.02051,0.598,,,
6546.11182,-0.402,,,
6546.20361,0.598,,,
6546.29492,-0.402,,,
6546.38672,-0.402,,,
6546.47803,0.598,,,
6546.56982,-0.402,,,
6546.66113,-0.402,,,
6546.75244,0.598,,,
6546.84424,-0.402,,,
6546.93555,-0.402,,,
6547.02734,0.598,,,
6547.11865,-0.402,,,
6547.21045,0.598,,,
6547.30176,-0.402,,,
6547.39355,0.598,,,
6547.48486,-0.402,,,
6547.57617,0.598,,,
6547.66797,-0.402,,,
6547.75928,-0.402,,,
6547.85107,-0.402,,,
6547.94238,0.598,,,
6548.03418,-0.402,,,
6548.12549,-0.402,,,
6548.21680,-0.402,,,
6548.30859,0.598,,,
6548.39990,-0.402,,,
6548.49170,0.598,,,
6548.58301,0.598,,,
6548.67480,-0.402,,,
6548.76611,-0.402,,,
6548.85742,-0.402,,,
6548.94922,-0.402,,,
6549.04053,-0.402,,,
6549.13232,-0.402,,,
6549.22363,-0.402,,,
6549.31543,-0.402,,,
6549.40674,-0.402,,,
6549.49854,-0.402,,,
6549.58984,-0.402,,,
6549.68115,0.598,,,
6549.77295,0.598,,,
6549.86426,0.598,,,
6549.95605,0.598,,,
6550.04736,-0.402,,,
6550.13916,0.598,,,
6550.23047,-0.402,,,
6550.32178,-0.402,,,
6550.41357,-0.402,,,
6550.50488,-0.402,,,
6550.59668,-0.402,,,
6550.68799,-0.402,,,
6550.77979,-0.402,,,
6550.87109,0.598,,,
6550.96240,0.598,,,
6551.05420,0.598,,,
6551.14551,0.598,,,
6551.23730,-0.402,,,
6551.32861,-0.402,,,
6551.42041,-0.402,,,
6551.51172,-0.402,,,
6551.60352,0.598,,,
6551.69482,-0.402,,,
6551.78613,0.598,,,
6551.87793,-0.402,,,
6551.96924,-0.402,,,
6552.06104,0.598,,,
6552.15234,-0.402,,,
6552.24414,-0.402,,,
6552.33545,-0.402,,,
6552.42676,-0.402,,,
6552.51855,-0.402,,,
6552.60986,-0.402,,,
6552.70166,-0.402,,,
6552.79297,-1.402,,,
6552.88477,-0.402,,,
6552.97607,-0.402,,,
6553.06738,-1.402,,,
6553.15918,-0.402,,,
6553.25049,-0.402,,,
6553.34229,0.598,,,
6553.43359,0.598,,,
6553.52539,0.598,,,
6553.61670,0.598,,,
6553.70801,0.598,,,
6553.79980,1.598,,,
6553.89111,0.598,,,
6553.98291,0.598,,,
6554.07422,0.598,,,
6554.16602,0.598,,,
6554.25732,0.598,,,
6554.34912,-0.402,,,
6554.44043,-0.402,,,
6554.53174,0.598,,,
6554.62354,-0.402,,,
6554.71484,-0.402,,,
6554.80664,-0.402,,,
6554.89795,-0.402,,,
6554.98975,-0.402,,,
6555.08105,-0.402,,,
6555.17236,-0.402,,,
6555.26416,-0.402,,,
6555.35547,-0.402,,,
6555.44727,-0.402,,,
6555.53857,-0.402,,,
6555.63037,-0.402,,,
6555.72168,-0.402,,,
6555.81299,-0.402,,,
6555.90479,-0.402,,,
6555.99609,-0.402,,,
6556.08789,-0.402,,,
6556.17920,-0.402,,,
6556.27100,-0.402,,,
6556.36230,-0.402,,,
6556.45410,-0.402,,,
6556.54541,-0.402,,,
6556.63672,-0.402,,,
6556.72852,0.598,,,
6556.81982,-0.402,,,
6556.91162,0.598,,,
6557.00293,-0.402,,,
6557.09473,-0.402,,,
6557.18604,-0.402,,,
6557.27734,0.598,,,
6557.36914,0.598,,,
6557.46045,-0.402,,,
6557.55225,-0.402,,,
6557.64355,-0.402,,,
6557.73535,-0.402,,,
6557.82666,-0.402,,,
6557.91797,-0.402,,,
6558.00977,0.598,,,
6558.10107,0.598,,,
6558.19287,0.598,,,
6558.28418,0.598,,,
6558.37598,0.598,,,
6558.46729,-0.402,,,
6558.55908,0.598,,,
6558.65039,0.598,,,
6558.74170,0.598,,,
6558.83350,-0.402,,,
6558.92480,0.598,,,
6559.01660,-0.402,,,
6559.10791,-0.402,,,
6559.19971,-0.402,,,
6559.29102,0.598,,,
6559.38232,0.598,,,
6559.47412,-0.402,,,
6559.56543,-0.402,,,
6559.65723,0.598,,,
6559.74854,-0.402,,,
6559.84033,-0.402,,,
6559.93164,0.598,,,
6560.02295,-0.402,,,
6560.11475,-0.402,,,
6560.20605,-0.402,,,
6560.29785,-0.402,,,
6560.38916,-0.402,,,
6560.48096,-0.402,,,
6560.57227,-0.402,,,
6560.66406,-0.402,,,
6560.75537,-0.402,,,
6560.84668,-0.402,,,
6560.93848,-0.402,,,
6561.02979,-0.402,,,
6561.12158,0.598,,,
6561.21289,-0.402,,,
6561.30469,-0.402,,,
6561.39600,-0.402,,,
6561.48730,-0.402,,,
6561.57910,-0.402,,,
6561.67041,-0.402,,,
6561.76221,0.598,,,
6561.85352,-0.402,,,
6561.94531,-0.402,,,
6562.03662,-0.402,,,
6562.12793,-0.402,,,
6562.21973,-0.402,,,
6562.31104,0.598,,,
6562.40283,-0.402,,,
6562.49414,-0.402,,,
6562.58594,0.598,,,
6562.67725,-0.402,,,
6562.76904,-0.402,,,
6562.86035,-0.402,,,
6562.95166,0.598,,,
6563.04346,-0.402,,,
6563.13477,-0.402,,,
6563.22656,-0.402,,,
6563.31787,-0.402,,,
6563.40967,-0.402,,,
6563.50098,-0.402,,,
6563.59229,-0.402,,,
6563.68408,-0.402,,,
6563.77539,-0.402,,,
6563.86719,-0.402,,,
6563.95850,-0.402,,,
6564.05029,0.598,,,
6564.14160,-0.402,,,
6564.23291,-0.402,,,
6564.32471,-0.402,,,
6564.41602,-0.402,,,
6564.50781,-0.402,,,
6564.59912,-0.402,,,
6564.69092,-0.402,,,
6564.78223,-0.402,,,
6564.87402,-0.402,,,
6564.96533,-0.402,,,
6565.05664,-0.402,,,
6565.14844,-0.402,,,
6565.23975,-0.402,,,
6565.33154,-0.402,,,
6565.42285,0.598,,,
6565.51465,0.598,,,
6565.60596,-0.402,,,
6565.69727,-0.402,,,
6565.78906,-0.402,,,
6565.88037,-0.402,,,
6565.97217,-0.402,,,
6566.06348,-0.402,,,
6566.15527,-0.402,,,
6566.24658,-0.402,,,
6566.33789,-0.402,,,
6566.42969,0.598,,,
6566.52100,0.598,,,
6566.61279,-0.402,,,
6566.70410,0.598,,,
6566.79590,-0.402,,,
6566.88721,0.598,,,
6566.97852,0.598,,,
6567.07031,-0.402,,,
6567.16162,-0.402,,,
6567.25342,-0.402,,,
6567.34473,-0.402,,,
6567.43652,-0.402,,,
6567.52783,-0.402,,,
6567.61963,0.598,,,
6567.71094,0.598,,,
6567.80225,-0.402,,,
6567.89404,-0.402,,,
6567.98535,-0.402,,,
6568.07715,-0.402,,,
6568.16846,0.598,,,
6568.26025,0.598,,,
6568.35156,-0.402,,,
6568.44287,0.598,,,
6568.53467,0.598,,,
6568.62598,-0.402,,,
6568.71777,0.598,,,
6568.80908,-0.402,,,
6568.90088,-0.402,,,
6568.99219,-0.402,,,
6569.08350,-0.402,,,
6569.17529,-0.402,,,
6569.26660,-0.402,,,
6569.35840,-0.402,,,
6569.44971,-0.402,,,
6569.54150,-0.402,,,
6569.63281,0.598,,,
6569.72461,-0.402,,,
6569.81592,-0.402,,,
6569.90723,0.598,,,
6569.99902,-0.402,,,
6570.09033,-0.402,,,
6570.18213,-0.402,,,
6570.27344,-0.402,,,
6570.36523,-0.402,,,
6570.45654,-0.402,,,
6570.54785,-0.402,,,
6570.63965,-0.402,,,
6570.73096,-0.402,,,
6570.82275,-0.402,,,
6570.91406,-0.402,,,
6571.00586,-0.402,,,
6571.09717,-0.402,,,
6571.18848,-0.402,,,
6571.28027,-0.402,,,
6571.37158,-0.402,,,
6571.46338,-0.402,,,
6571.55469,-0.402,,,
6571.64648,-0.402,,,
6571.73779,-0.402,,,
6571.82959,-0.402,,,
6571.92090,-0.402,,,
6572.01221,-0.402,,,
6572.10400,-0.402,,,
6572.19531,-0.402,,,
6572.28711,-0.402,,,
6572.37842,-0.402,,,
6572.47021,-0.402,,,
6572.56152,-0.402,,,
6572.65283,-1.402,,,
6572.74463,-1.402,,,
6572.83594,-0.402,,,
6572.92773,-1.402,,,
6573.01904,-1.402,,,
6573.11084,-0.402,,,
6573.20215,-0.402,,,
6573.29346,-0.402,,,
6573.38525,-0.402,,,
6573.47656,-0.402,,,
6573.56836,-0.402,,,
6573.65967,-0.402,,,
6573.75146,-0.402,,,
6573.84277,-0.402,,,
6573.93457,-0.402,,,
6574.02588,0.598,,,
6574.11719,-0.402,,,
6574.20898,-0.402,,,
6574.30029,0.598,,,
6574.39209,0.598,,,
6574.48340,-0.402,,,
6574.57520,0.598,,,
6574.66650,0.598,,,
6574.75781,-0.402,,,
6574.84961,0.598,,,
6574.94092,0.598,,,
6575.03271,-0.402,,,
6575.12402,-0.402,,,
6575.21582,-0.402,,,
6575.30713,-0.402,,,
6575.39844,-0.402,,,
6575.49023,-0.402,,,
6575.58154,0.598,,,
6575.67334,0.598,,,
6575.76465,0.598,,,
6575.85645,-0.402,,,
6575.94775,-0.402,,,
6576.03955,-0.402,,,
6576.13086,-0.402,,,
6576.22217,-0.402,,,
6576.31396,0.598,,,
6576.40527,0.598,,,
6576.49707,-0.402,,,
6576.58838,-0.402,,,
6576.68018,-0.402,,,
6576.77148,0.598,,,
6576.86279,-0.402,,,
6576.95459,-0.402,,,
6577.04590,0.598,,,
6577.13770,-0.402,,,
6577.22900,0.598,,,
6577.32080,-0.402,,,
6577.41211,-0.402,,,
6577.50342,0.598,,,
6577.59521,-0.402,,,
6577.68652,0.598,,,
6577.77832,-0.402,,,
6577.86963,-0.402,,,
6577.96143,0.598,,,
6578.05273,-0.402,,,
6578.14404,0.598,,,
6578.23584,-0.402,,,
6578.32715,0.598,,,
6578.41895,0.598,,,
6578.51025,-0.402,,,
6578.60205,0.598,,,
6578.69336,0.598,,,
6578.78516,-0.402,,,
6578.87646,0.598,,,
6578.96777,0.598,,,
6579.05957,0.598,,,
6579.15088,0.598,,,
6579.24268,0.598,,,
6579.33398,0.598,,,
6579.42578,-0.402,,,
6579.51709,0.598,,,
6579.60840,-0.402,,,
6579.70020,-0.402,,,
6579.79150,0.598,,,
6579.88330,-0.402,,,
6579.97461,-0.402,,,
6580.06641,-0.402,,,
6580.15771,0.598,,,
6580.24902,-0.402,,,
6580.34082,-0.402,,,
6580.43213,-0.402,,,
6580.52393,-0.402,,,
6580.61523,0.598,,,
6580.70703,-0.402,,,
6580.79834,-0.402,,,
6580.89014,-0.402,,,
6580.98145,-0.402,,,
6581.07275,-0.402,,,
6581.16455,-0.402,,,
6581.25586,-0.402,,,
6581.34766,-0.402,,,
6581.43896,-0.402,,,
6581.53076,-0.402,,,
6581.62207,0.598,,,
6581.71338,-0.402,,,
6581.80518,-0.402,,,
6581.89648,-0.402,,,
6581.98828,0.598,,,
6582.07959,-0.402,,,
6582.17139,0.598,,,
6582.26270,0.598,,,
6582.35400,0.598,,,
6582.44580,-0.402,,,
6582.53711,-0.402,,,
6582.62891,0.598,,,
6582.72021,-0.402,,,
6582.81201,-0.402,,,
6582.90332,-0.402,,,
6582.99512,-0.402,,,
6583.08643,0.598,,,
6583.17773,-0.402,,,
6583.26953,-0.402,,,
6583.36084,-0.402,,,
6583.45264,-0.402,,,
6583.54395,-0.402,,,
6583.63574,-0.402,,,
6583.72705,-0.402,,,
6583.81836,-0.402,,,
6583.91016,-0.402,,,
6584.00146,-0.402,,,
6584.09326,-0.402,,,
6584.18457,-0.402,,,
6584.27637,-0.402,,,
6584.36768,-0.402,,,
6584.45898,-0.402,,,
6584.55078,0.598,,,
6584.64209,-0.402,,,
6584.73389,-0.402,,,
6584.82520,0.598,,,
6584.91699,-0.402,,,
6585.00830,-0.402,,,
6585.10010,-0.402,,,
6585.19141,-0.402,,,
6585.28271,-0.402,,,
6585.37451,-0.402,,,
6585.46582,-0.402,,,
6585.55762,-0.402,,,
6585.64893,-0.402,,,
6585.74072,-0.402,,,
6585.83203,-0.402,,,
6585.92334,-0.402,,,
6586.01514,0.598,,,
6586.10645,0.598,,,
6586.19824,-0.402,,,
6586.28955,-0.402,,,
6586.38135,-0.402,,,
6586.47266,-0.402,,,
6586.56396,-0.402,,,
6586.65576,-0.402,,,
6586.74707,-0.402,,,
6586.83887,-0.402,,,
6586.93018,-0.402,,,
6587.02197,-0.402,,,
6587.11328,-0.402,,,
6587.20508,-0.402,,,
6587.29639,-0.402,,,
6587.38770,-0.402,,,
6587.47949,-0.402,,,
6587.57080,-0.402,,,
6587.66260,-0.402,,,
6587.75391,-0.402,,,
6587.84570,-0.402,,,
6587.93701,-0.402,,,
6588.02832,-0.402,,,
6588.12012,0.598,,,
6588.21143,-0.402,,,
6588.30322,-0.402,,,
6588.39453,-0.402,,,
6588.48633,-0.402,,,
6588.57764,-0.402,,,
6588.66895,-0.402,,,
6588.76074,-0.402,,,
6588.85205,-0.402,,,
6588.94385,-0.402,,,
6589.03516,-0.402,,,
6589.12695,-0.402,,,
6589.21826,-1.402,,,
6589.31006,-1.402,,,
6589.40137,-1.402,,,
6589.49268,-1.402,,,
6589.58447,-0.402,,,
6589.67578,-0.402,,,
6589.76758,-1.402,,,
6589.85889,-0.402,,,
6589.95068,-0.402,,,
6590.04199,-0.402,,,
6590.13330,-1.402,,,
6590.22510,-0.402,,,
6590.31641,-0.402,,,
6590.40820,-0.402,,,
6590.49951,-0.402,,,
6590.59131,-0.402,,,
6590.68262,-0.402,,,
6590.77393,-0.402,,,
6590.86572,-0.402,,,
6590.95703,-0.402,,,
6591.04883,-0.402,,,
6591.14014,-1.402,,,
6591.23193,-0.402,,,
6591.32324,-1.402,,,
6591.41455,-1.402,,,
6591.50635,-1.402,,,
6591.59766,-1.402,,,
6591.68945,-2.402,,,
6591.78076,-2.402,,,
6591.87256,-1.402,,,
6591.96387,-2.402,,,
6592.05566,-1.402,,,
6592.14697,-1.402,,,
6592.23828,-0.402,,,
6592.33008,-1.402,,,
6592.42139,-0.402,,,
6592.51318,-1.402,,,
6592.60449,-0.402,,,
6592.69629,-0.402,,,
6592.78760,-0.402,,,
6592.87891,-0.402,,,
6592.97070,-0.402,,,
6593.06201,-0.402,,,
6593.15381,-0.402,,,
6593.24512,-0.402,,,
6593.33691,-0.402,,,
6593.42822,-0.402,,,
6593.51953,-0.402,,,
6593.61133,-0.402,,,
6593.70264,-0.402,,,
6593.79443,-0.402,,,
6593.88574,-0.402,,,
6593.97754,-0.402,,,
6594.06885,-0.402,,,
6594.16064,-0.402,,,
6594.25195,-0.402,,,
6594.34326,-0.402,,,
6594.43506,-1.402,,,
6594.52637,-0.402,,,
6594.61816,-0.402,,,
6594.70947,-0.402,,,
6594.80127,0.598,,,
6594.89258,-0.402,,,
6594.98389,0.598,,,
6595.07568,-0.402,,,
6595.16699,-0.402,,,
6595.25879,-0.402,,,
6595.35010,-0.402,,,
6595.44189,-0.402,,,
6595.53320,-0.402,,,
6595.62451,-0.402,,,
6595.71631,-0.402,,,
6595.80762,-0.402,,,
6595.89941,-0.402,,,
6595.99072,-0.402,,,
6596.08252,-0.402,,,
6596.17383,-0.402,,,
6596.26563,-0.402,,,
6596.35693,-0.402,,,
6596.44824,-0.402,,,
6596.54004,-0.402,,,
6596.63135,-0.402,,,
6596.72314,-0.402,,,
6596.81445,-0.402,,,
6596.90625,-0.402,,,
6596.99756,-0.402,,,
6597.08887,-0.402,,,
6597.18066,-0.402,,,
6597.27197,-0.402,,,
6597.36377,-0.402,,,
6597.45508,-0.402,,,
6597.54688,-0.402,,,
6597.63818,-0.402,,,
6597.72949,-0.402,,,
6597.82129,-0.402,,,
6597.91260,-0.402,,,
6598.00439,-0.402,,,
6598.09570,-0.402,,,
6598.18750,-0.402,,,
6598.27881,-0.402,,,
6598.37061,-0.402,,,
6598.46191,-0.402,,,
6598.55322,-0.402,,,
6598.64502,-0.402,,,
6598.73633,-1.402,,,
6598.82813,-1.402,,,
6598.91943,-1.402,,,
6599.01123,-1.402,,,
6599.10254,-1.402,,,
6599.19385,-0.402,,,
6599.28564,-0.402,,,
6599.37695,-0.402,,,
6599.46875,-0.402,,,
6599.56006,-1.402,,,
6599.65186,-1.402,,,
6599.74316,-0.402,,,
6599.83447,-0.402,,,
6599.92627,-0.402,,,
6600.01758,-0.402,,,
6600.10938,-1.402,,,
6600.20068,-0.402,,,
6600.29248,-1.402,,,
6600.38379,-0.402,,,
6600.47559,-0.402,,,
6600.56689,-1.402,,,
6600.65820,-0.402,,,
6600.75000,-0.402,,,
6600.84131,-0.402,,,
6600.93311,-0.402,,,
6601.02441,-0.402,,,
6601.11621,-0.402,,,
6601.20752,-0.402,,,
6601.29883,-0.402,,,
6601.39063,-0.402,,,
6601.48193,-0.402,,,
6601.57373,-0.402,,,
6601.66504,-0.402,,,
6601.75684,-1.402,,,
6601.84814,-1.402,,,
6601.93945,-1.402,,,
6602.03125,-0.402,,,
6602.12256,-0.402,,,
6602.21436,-0.402,,,
6602.30566,-0.402,,,
6602.39746,-1.402,,,
6602.48877,-0.402,,,
6602.58057,-0.402,,,
6602.67188,-1.402,,,
6602.76318,-1.402,,,
6602.85498,-1.402,,,
6602.94629,-0.402,,,
6603.03809,-0.402,,,
6603.12939,-0.402,,,
6603.22119,-0.402,,,
6603.31250,-0.402,,,
6603.40381,-0.402,,,
6603.49561,-0.402,,,
6603.58691,-0.402,,,
6603.67871,-1.402,,,
6603.77002,-0.402,,,
6603.86182,-0.402,,,
6603.95313,-0.402,,,
6604.04443,-0.402,,,
6604.13623,-0.402,,,
6604.22754,-0.402,,,
6604.31934,-0.402,,,
6604.41064,-1.402,,,
6604.50244,-1.402,,,
6604.59375,-1.402,,,
6604.68506,-0.402,,,
6604.77686,-0.402,,,
6604.86816,-1.402,,,
6604.95996,-0.402,,,
6605.05127,-1.402,,,
6605.14307,-1.402,,,
6605.23438,-0.402,,,
6605.32617,-0.402,,,
6605.41748,-0.402,,,
6605.50879,-1.402,,,
6605.60059,-0.402,,,
6605.69189,-0.402,,,
6605.78369,-1.402,,,
6605.87500,-1.402,,,
6605.96680,-0.402,,,
6606.05811,-1.402,,,
6606.14941,-1.402,,,
6606.24121,-0.402,,,
6606.33252,-0.402,,,
6606.42432,-1.402,,,
6606.51563,-0.402,,,
6606.60742,-0.402,,,
6606.69873,-0.402,,,
6606.79004,-1.402,,,
6606.88184,-0.402,,,
6606.97314,-0.402,,,
6607.06494,-0.402,,,
6607.15625,-0.402,,,
6607.24805,-0.402,,,
6607.33936,-1.402,,,
6607.43115,-1.402,,,
6607.52246,-1.402,,,
6607.61377,-1.402,,,
6607.70557,-1.402,,,
6607.79688,-1.402,,,
6607.88867,-0.402,,,
6607.97998,-0.402,,,
6608.07178,-0.402,,,
6608.16309,-0.402,,,
6608.25439,-0.402,,,
6608.34619,-0.402,,,
6608.43750,-0.402,,,
6608.52930,-0.402,,,
6608.62061,-0.402,,,
6608.71240,-0.402,,,
6608.80371,-0.402,,,
6608.89502,-0.402,,,
6608.98682,-0.402,,,
6609.07813,-0.402,,,
6609.16992,-1.402,,,
6609.26123,-0.402,,,
6609.35303,-0.402,,,
6609.44434,-0.402,,,
6609.53613,-0.402,,,
6609.62744,0.598,,,
6609.71875,-0.402,,,
6609.81055,-0.402,,,
6609.90186,-0.402,,,
6609.99365,-0.402,,,
6610.08496,-1.402,,,
6610.17676,-0.402,,,
6610.26807,-0.402,,,
6610.35938,-0.402,,,
6610.45117,-0.402,,,
6610.54248,-0.402,,,
6610.63428,0.598,,,
6610.72559,-0.402,,,
6610.81738,-0.402,,,
6610.90869,0.598,,,
6611.00000,-0.402,,,
6611.09180,-0.402,,,
6611.18311,-0.402,,,
6611.27490,-1.402,,,
6611.36621,-1.402,,,
6611.45801,-0.402,,,
6611.54932,-0.402,,,
6611.64111,-1.402,,,
6611.73242,-1.402,,,
6611.82373,-0.402,,,
6611.91553,-1.402,,,
6612.00684,-0.402,,,
6612.09863,-1.402,,,
6612.18994,-1.402,,,
6612.28174,-1.402,,,
6612.37305,-0.402,,,
6612.46436,-0.402,,,
6612.55615,-1.402,,,
6612.64746,-0.402,,,
6612.73926,-1.402,,,
6612.83057,-1.402,,,
6612.92236,-0.402,,,
6613.01367,-0.402,,,
6613.10498,-0.402,,,
6613.19678,-1.402,,,
6613.28809,-0.402,,,
6613.37988,-0.402,,,
6613.47119,-1.402,,,
6613.56299,-1.402,,,
6613.65430,-0.402,,,
6613.74609,-1.402,,,
6613.83740,-0.402,,,
6613.92871,-0.402,,,
6614.02051,-1.402,,,
6614.11182,-1.402,,,
6614.20361,-0.402,,,
6614.29492,-1.402,,,
6614.38672,-1.402,,,
6614.47803,-0.402,,,
6614.56934,-0.402,,,
6614.66113,-0.402,,,
6614.75244,-0.402,,,
6614.84424,-0.402,,,
6614.93555,-1.402,,,
6615.02734,-0.402,,,
6615.11865,-0.402,,,
6615.20996,-0.402,,,
6615.30176,-0.402,,,
6615.39307,-0.402,,,
6615.48486,-0.402,,,
6615.57617,-0.402,,,
6615.66797,-0.402,,,
6615.75928,-0.402,,,
6615.85059,-0.402,,,
6615.94238,-0.402,,,
6616.03369,-0.402,,,
6616.12549,-0.402,,,
6616.21680,-1.402,,,
6616.30859,-0.402,,,
6616.39990,-0.402,,,
6616.49170,-1.402,,,
6616.58301,-1.402,,,
6616.67432,-0.402,,,
6616.76611,-0.402,,,
6616.85742,-0.402,,,
6616.94922,-0.402,,,
6617.04053,-0.402,,,
6617.13232,-0.402,,,
6617.22363,-0.402,,,
6617.31494,-0.402,,,
6617.40674,-1.402,,,
6617.49805,-0.402,,,
6617.58984,-0.402,,,
6617.68115,-0.402,,,
6617.77295,-1.402,,,
6617.86426,-0.402,,,
6617.95557,-0.402,,,
6618.04736,-0.402,,,
6618.13867,-0.402,,,
6618.23047,-0.402,,,
6618.32178,-1.402,,,
6618.41357,-0.402,,,
6618.50488,-0.402,,,
6618.59668,-0.402,,,
6618.68799,-0.402,,,
6618.77930,-0.402,,,
6618.87109,-0.402,,,
6618.96240,-0.402,,,
6619.05420,-0.402,,,
6619.14551,-0.402,,,
6619.23730,-0.402,,,
6619.32861,-1.402,,,
6619.41992,-0.402,,,
6619.51172,-0.402,,,
6619.60303,-0.402,,,
6619.69482,0.598,,,
6619.78613,-0.402,,,
6619.87793,-0.402,,,
6619.96924,-0.402,,,
6620.06055,-0.402,,,
6620.15234,-0.402,,,
6620.24365,-0.402,,,
6620.33545,-0.402,,,
6620.42676,-0.402,,,
6620.51855,-1.402,,,
6620.60986,-1.402,,,
6620.70166,-0.402,,,
6620.79297,-0.402,,,
6620.88428,-1.402,,,
6620.97607,-0.402,,,
6621.06738,-1.402,,,
6621.15918,-0.402,,,
6621.25049,-1.402,,,
6621.34229,-0.402,,,
6621.43359,-1.402,,,
6621.52490,-0.402,,,
6621.61670,-0.402,,,
6621.70801,-1.402,,,
6621.79980,-0.402,,,
6621.89111,-1.402,,,
6621.98291,-1.402,,,
6622.07422,-1.402,,,
6622.16553,-1.402,,,
6622.25732,-1.402,,,
6622.34863,-1.402,,,
6622.44043,-1.402,,,
6622.53174,-0.402,,,
6622.62354,-0.402,,,
6622.71484,-0.402,,,
6622.80664,-0.402,,,
6622.89795,-0.402,,,
6622.98926,-1.402,,,
6623.08105,-0.402,,,
6623.17236,-0.402,,,
6623.26416,-0.402,,,
6623.35547,-0.402,,,
6623.44727,-0.402,,,
6623.53857,-0.402,,,
6623.62988,-0.402,,,
6623.72168,-1.402,,,
6623.81299,-1.402,,,
6623.90479,-1.402,,,
6623.99609,-0.402,,,
6624.08789,-0.402,,,
6624.17920,-1.402,,,
6624.27051,-0.402,,,
6624.36230,-0.402,,,
6624.45361,-0.402,,,
6624.54541,-1.402,,,
6624.63672,-1.402,,,
6624.72852,-0.402,,,
6624.81982,-1.402,,,
6624.91162,-0.402,,,
6625.00293,-1.402,,,
6625.09424,-1.402,,,
6625.18604,-1.402,,,
6625.27734,-1.402,,,
6625.36914,-1.402,,,
6625.46045,-1.402,,,
6625.55225,-0.402,,,
6625.64355,-1.402,,,
6625.73486,-1.402,,,
6625.82666,-0.402,,,
6625.91797,-0.402,,,
6626.00977,-0.402,,,
6626.10107,-1.402,,,
6626.19287,-1.402,,,
6626.28418,-0.402,,,
6626.37549,-0.402,,,
6626.46729,-0.402,,,
6626.55859,-0.402,,,
6626.65039,-0.402,,,
6626.74170,-0.402,,,
6626.83350,-0.402,,,
6626.92480,-0.402,,,
6627.01660,-0.402,,,
6627.10791,-0.402,,,
6627.19922,-0.402,,,
6627.29102,-1.402,,,
6627.38232,-1.402,,,
6627.47412,-1.402,,,
6627.56543,-1.402,,,
6627.65723,-1.402,,,
6627.74854,-2.402,,,
6627.83984,-1.402,,,
6627.93164,-1.402,,,
6628.02295,-1.402,,,
6628.11475,-1.402,,,
6628.20605,-1.402,,,
6628.29785,-0.402,,,
6628.38916,-1.402,,,
6628.48047,-0.402,,,
6628.57227,-0.402,,,
6628.66357,-0.402,,,
6628.75537,-0.402,,,
6628.84668,-0.402,,,
6628.93848,-0.402,,,
6629.02979,-0.402,,,
6629.12109,-0.402,,,
6629.21289,-0.402,,,
6629.30420,-0.402,,,
6629.39600,-0.402,,,
6629.48730,-0.402,,,
6629.57910,-1.402,,,
6629.67041,-1.402,,,
6629.76221,-2.402,,,
6629.85352,-2.402,,,
6629.94482,-2.402,,,
6630.03662,-3.402,,,
6630.12793,-2.402,,,
6630.21973,-2.402,,,
6630.31104,-2.402,,,
6630.40283,-2.402,,,
6630.49414,-1.402,,,
6630.58545,-1.402,,,
6630.67725,-1.402,,,
6630.76855,-1.402,,,
6630.86035,-1.402,,,
6630.95166,-1.402,,,
6631.04346,-0.402,,,
6631.13477,-0.402,,,
6631.22607,-1.402,,,
6631.31787,-1.402,,,
6631.40918,-0.402,,,
6631.50098,-1.402,,,
6631.59229,-1.402,,,
6631.68408,-0.402,,,
6631.77539,-0.402,,,
6631.86719,-0.402,,,
6631.95850,-1.402,,,
6632.04980,-0.402,,,
6632.14160,-0.402,,,
6632.23291,-1.402,,,
6632.32471,-0.402,,,
6632.41602,-0.402,,,
6632.50781,-0.402,,,
6632.59912,-0.402,,,
6632.69043,-0.402,,,
6632.78223,-0.402,,,
6632.87354,-0.402,,,
6632.96533,-0.402,,,
6633.05664,-0.402,,,
6633.14844,-1.402,,,
6633.23975,-0.402,,,
6633.33105,-0.402,,,
6633.42285,-1.402,,,
6633.51416,-0.402,,,
6633.60596,-0.402,,,
6633.69727,-0.402,,,
6633.78906,-0.402,,,
6633.88037,-0.402,,,
6633.97217,-0.402,,,
6634.06348,-0.402,,,
6634.15479,-0.402,,,
6634.24658,-0.402,,,
6634.33789,-0.402,,,
6634.42969,-0.402,,,
6634.52100,-0.402,,,
6634.61279,-1.402,,,
6634.70410,-0.402,,,
6634.79541,-0.402,,,
6634.88721,-0.402,,,
6634.97852,-0.402,,,
6635.07031,-0.402,,,
6635.16162,-0.402,,,
6635.25342,-0.402,,,
6635.34473,-0.402,,,
6635.43604,-0.402,,,
6635.52783,-1.402,,,
6635.61914,-0.402,,,
6635.71094,-1.402,,,
6635.80225,-0.402,,,
6635.89404,-0.402,,,
6635.98535,-0.402,,,
6636.07715,-0.402,,,
6636.16846,-0.402,,,
6636.25977,-0.402,,,
6636.35156,-0.402,,,
6636.44287,-1.402,,,
6636.53467,-0.402,,,
6636.62598,-0.402,,,
6636.71777,-0.402,,,
6636.80908,-1.402,,,
6636.90039,-0.402,,,
6636.99219,-1.402,,,
6637.08350,-1.402,,,
6637.17529,-0.402,,,
6637.26660,-0.402,,,
6637.35840,-0.402,,,
6637.44971,-0.402,,,
6637.54102,-0.402,,,
6637.63281,-0.402,,,
6637.72412,-1.402,,,
6637.81592,-0.402,,,
6637.90723,-1.402,,,
6637.99902,-1.402,,,
6638.09033,-0.402,,,
6638.18213,-1.402,,,
6638.27344,-0.402,,,
6638.36475,-1.402,,,
6638.45654,-0.402,,,
6638.54785,-1.402,,,
6638.63965,-1.402,,,
6638.73096,-0.402,,,
6638.82275,-0.402,,,
6638.91406,-1.402,,,
6639.00537,-0.402,,,
6639.09717,-0.402,,,
6639.18848,-0.402,,,
6639.28027,-0.402,,,
6639.37158,-0.402,,,
6639.46338,-0.402,,,
6639.55469,-0.402,,,
6639.64600,-0.402,,,
6639.73779,-0.402,,,
6639.82910,-1.402,,,
6639.92090,-1.402,,,
,,,,