2018-08-16_02:26:11.660651Z ISC_DRMI executing state: PREP_DRMI (20) 2018-08-16_02:26:11.661237Z ISC_DRMI [PREP_DRMI.enter] 2018-08-16_02:26:11.700676Z ISC_DRMI REQUEST: PREP_DRMI_ASC 2018-08-16_02:26:11.701550Z ISC_DRMI STALL cleared 2018-08-16_02:26:11.702143Z ISC_DRMI calculating path: PREP_DRMI->PREP_DRMI_ASC 2018-08-16_02:26:11.804745Z ISC_DRMI REQUEST: PREP_DRMI_ASC 2018-08-16_02:26:11.805297Z ISC_DRMI calculating path: PREP_DRMI->PREP_DRMI_ASC 2018-08-16_02:26:11.916840Z ISC_DRMI [PREP_DRMI.main] ezca: H1:LSC-MICH2 => ONLY ON: INPUT, FM1, FM2, OUTPUT, DECIMATION 2018-08-16_02:26:11.929953Z ISC_DRMI [PREP_DRMI.main] ezca: H1:LSC-PD_DOF_MTRX_SETTING_3_16 => 0 2018-08-16_02:26:11.933769Z ISC_DRMI [PREP_DRMI.main] ezca: H1:LSC-MICH1_SW1S => 0 2018-08-16_02:26:12.184671Z ISC_DRMI [PREP_DRMI.main] ezca: H1:LSC-MICH1 => ONLY ON: DECIMATION, OUTPUT 2018-08-16_02:26:12.188044Z ISC_DRMI [PREP_DRMI.main] ezca: H1:LSC-PD_DOF_MTRX_SETTING_4_13 => 0 2018-08-16_02:26:12.210711Z ISC_DRMI [PREP_DRMI.main] ezca: H1:LSC-PRCL1_SW1S => 0 2018-08-16_02:26:12.336737Z ISC_DRMI [PREP_DRMI.main] ezca: H1:LSC-PRCL1_SW2S => 1536 2018-08-16_02:26:12.462423Z ISC_DRMI [PREP_DRMI.main] ezca: H1:LSC-PRCL1 => ONLY ON: DECIMATION, OUTPUT 2018-08-16_02:26:12.466004Z ISC_DRMI [PREP_DRMI.main] ezca: H1:LSC-PRCL1_SW1 => 1024 2018-08-16_02:26:12.721309Z ISC_DRMI [PREP_DRMI.main] ezca: H1:LSC-PRCL1 => ON: FM4 2018-08-16_02:26:12.848044Z ISC_DRMI [PREP_DRMI.main] ezca: H1:LSC-PRCL1_SW2 => 16 2018-08-16_02:26:12.974562Z ISC_DRMI [PREP_DRMI.main] ezca: H1:LSC-PRCL1 => ON: FM9 2018-08-16_02:26:13.109853Z ISC_DRMI [PREP_DRMI.main] ezca: H1:LSC-PRCL1_SW2 => 64 2018-08-16_02:26:13.235703Z ISC_DRMI [PREP_DRMI.main] ezca: H1:LSC-PRCL1 => ON: FM10 2018-08-16_02:26:13.244700Z ISC_DRMI [PREP_DRMI.main] ezca: H1:LSC-PD_DOF_MTRX_SETTING_5_13 => 0 2018-08-16_02:26:13.245401Z ISC_DRMI [PREP_DRMI.main] ezca: H1:LSC-PD_DOF_MTRX_SETTING_5_15 => 0 2018-08-16_02:26:13.249755Z ISC_DRMI [PREP_DRMI.main] ezca: H1:LSC-SRCL1_SW1S => 0 2018-08-16_02:26:13.375682Z ISC_DRMI [PREP_DRMI.main] ezca: H1:LSC-SRCL1_SW2S => 1536 2018-08-16_02:26:13.508279Z ISC_DRMI [PREP_DRMI.main] ezca: H1:LSC-SRCL1 => ONLY ON: DECIMATION, OUTPUT 2018-08-16_02:26:13.659527Z ISC_DRMI [PREP_DRMI.main] ezca: H1:LSC-SRCL1_SW2 => 16 2018-08-16_02:26:13.785542Z ISC_DRMI [PREP_DRMI.main] ezca: H1:LSC-SRCL1 => ON: FM9 2018-08-16_02:26:13.912905Z ISC_DRMI [PREP_DRMI.main] ezca: H1:LSC-SRCL1_SW2 => 64 2018-08-16_02:26:14.038906Z ISC_DRMI [PREP_DRMI.main] ezca: H1:LSC-SRCL1 => ON: FM10 2018-08-16_02:26:14.291015Z ISC_DRMI [PREP_DRMI.main] ezca: H1:LSC-PRCL2 => OFF: FM6 2018-08-16_02:26:14.543062Z ISC_DRMI [PREP_DRMI.main] ezca: H1:LSC-SRCL2 => OFF: FM6 2018-08-16_02:26:14.549320Z ISC_DRMI [PREP_DRMI.main] ezca: H1:LSC-PD_DOF_MTRX_SETTING_3_16 => 4 2018-08-16_02:26:14.550021Z ISC_DRMI [PREP_DRMI.main] ezca: H1:LSC-PD_DOF_MTRX_SETTING_4_13 => 3.5 2018-08-16_02:26:14.550772Z ISC_DRMI [PREP_DRMI.main] ezca: H1:LSC-PD_DOF_MTRX_SETTING_5_15 => 4 2018-08-16_02:26:14.551242Z ISC_DRMI [PREP_DRMI.main] ezca: H1:LSC-PD_DOF_MTRX_SETTING_5_13 => -5.508 2018-08-16_02:26:14.652629Z ISC_DRMI [PREP_DRMI.main] ezca: H1:LSC-PD_DOF_MTRX_LOAD_MATRIX => 1 2018-08-16_02:26:14.692752Z ISC_DRMI [PREP_DRMI.main] setting MICH trigger thresholds for DRMI with arms 2018-08-16_02:26:15.044617Z ISC_DRMI [PREP_DRMI.main] ezca: H1:ASC-MICH_P => ONLY ON: INPUT, FM1, FM3, FM7, FM10, OUTPUT, DECIMATION 2018-08-16_02:26:15.297135Z ISC_DRMI [PREP_DRMI.main] ezca: H1:ASC-MICH_Y => ONLY ON: INPUT, FM1, FM3, FM4, FM8, FM10, OUTPUT, DECIMATION 2018-08-16_02:26:15.424451Z ISC_DRMI [PREP_DRMI.main] ezca: H1:SUS-BS_M3_ISCINF_L_SW2 => 256 2018-08-16_02:26:15.549897Z ISC_DRMI [PREP_DRMI.main] ezca: H1:SUS-BS_M3_ISCINF_L => ON: LIMIT 2018-08-16_02:26:15.551333Z ISC_DRMI [PREP_DRMI.main] ezca: H1:SUS-BS_M3_ISCINF_L => OFF: FM4, FM5, FM6 2018-08-16_02:26:15.803240Z ISC_DRMI [PREP_DRMI.main] ezca: H1:SUS-BS_M1_LOCK_L => OFF: INPUT, FM1 2018-08-16_02:26:16.056535Z ISC_DRMI [PREP_DRMI.main] ezca: H1:SUS-BS_M2_LOCK_L => ON: FM4, FM5, FM9, FM10 2018-08-16_02:26:16.057902Z ISC_DRMI [PREP_DRMI.main] ezca: H1:SUS-BS_M3_LOCK_L_SW1 => 64 2018-08-16_02:26:16.308918Z ISC_DRMI [PREP_DRMI.main] ezca: H1:SUS-BS_M3_LOCK_L => ON: FM2 2018-08-16_02:26:16.310418Z ISC_DRMI [PREP_DRMI.main] ezca: H1:SUS-PRM_M1_LOCK_L_GAIN => 0 2018-08-16_02:26:16.311233Z ISC_DRMI [PREP_DRMI.main] ezca: H1:SUS-PRM_M1_LOCK_L => ONLY ON: FM2, FM4, FM6, FM8, FM9, FM10, INPUT, OUTPUT, DECIMATION 2018-08-16_02:26:16.311765Z ISC_DRMI [PREP_DRMI.main] ezca: H1:SUS-PRM_M2_LOCK_L => ONLY ON: INPUT, OUTPUT, DECIMATION 2018-08-16_02:26:16.312891Z ISC_DRMI [PREP_DRMI.main] ezca: H1:SUS-SRM_M1_LOCK_L_GAIN => 0 2018-08-16_02:26:16.330248Z ISC_DRMI [PREP_DRMI.main] ezca: H1:SUS-SRM_M1_LOCK_L => ONLY ON: FM2, FM4, FM6, FM8, FM10, INPUT, OUTPUT, DECIMATION 2018-08-16_02:26:16.331688Z ISC_DRMI [PREP_DRMI.main] ezca: H1:SUS-SRM_M2_LOCK_L => ONLY ON: INPUT, OUTPUT, DECIMATION 2018-08-16_02:26:16.333594Z ISC_DRMI [PREP_DRMI.main] ready for locking 2018-08-16_02:26:16.476767Z ISC_DRMI EDGE: PREP_DRMI->ACQUIRE_DRMI_1F 2018-08-16_02:26:16.477590Z ISC_DRMI calculating path: ACQUIRE_DRMI_1F->PREP_DRMI_ASC 2018-08-16_02:26:16.477970Z ISC_DRMI new target: DRMI_LOCKED 2018-08-16_02:26:16.479844Z ISC_DRMI executing state: ACQUIRE_DRMI_1F (30) 2018-08-16_02:26:16.479844Z ISC_DRMI [ACQUIRE_DRMI_1F.enter] 2018-08-16_02:26:16.482989Z ISC_DRMI [ACQUIRE_DRMI_1F.main] ezca: H1:LSC-MICH1_SW1 => 4 2018-08-16_02:26:16.483443Z ISC_DRMI [ACQUIRE_DRMI_1F.main] ezca: H1:LSC-MICH1 => ON: INPUT, OUTPUT 2018-08-16_02:26:16.484120Z ISC_DRMI [ACQUIRE_DRMI_1F.main] ezca: H1:LSC-MICH2 => ON: INPUT, OUTPUT 2018-08-16_02:26:16.484522Z ISC_DRMI [ACQUIRE_DRMI_1F.main] setting gains for DRMI with arms 2018-08-16_02:26:16.484900Z ISC_DRMI [ACQUIRE_DRMI_1F.main] ezca: H1:LSC-MICH1_GAIN => 2.8 2018-08-16_02:26:16.485747Z ISC_DRMI [ACQUIRE_DRMI_1F.main] ezca: H1:LSC-PRCL1_SW1 => 4 2018-08-16_02:26:16.486142Z ISC_DRMI [ACQUIRE_DRMI_1F.main] ezca: H1:LSC-PRCL1 => ON: INPUT, OUTPUT 2018-08-16_02:26:16.489634Z ISC_DRMI [ACQUIRE_DRMI_1F.main] ezca: H1:LSC-PRCL2 => ON: INPUT, OUTPUT 2018-08-16_02:26:16.490422Z ISC_DRMI [ACQUIRE_DRMI_1F.main] ezca: H1:LSC-PRCL1_GAIN => 16 2018-08-16_02:26:16.491160Z ISC_DRMI [ACQUIRE_DRMI_1F.main] ezca: H1:LSC-SRCL1_SW1 => 4 2018-08-16_02:26:16.491516Z ISC_DRMI [ACQUIRE_DRMI_1F.main] ezca: H1:LSC-SRCL1 => ON: INPUT, OUTPUT 2018-08-16_02:26:16.492437Z ISC_DRMI [ACQUIRE_DRMI_1F.main] ezca: H1:LSC-SRCL2 => ON: INPUT, OUTPUT 2018-08-16_02:26:16.493309Z ISC_DRMI [ACQUIRE_DRMI_1F.main] ezca: H1:LSC-SRCL1_GAIN => -30 2018-08-16_02:26:16.494002Z ISC_DRMI [ACQUIRE_DRMI_1F.main] ezca: H1:LSC-SRCL1_SW1 => 0 2018-08-16_02:26:16.744942Z ISC_DRMI [ACQUIRE_DRMI_1F.main] ezca: H1:LSC-SRCL1 => OFF: OFFSET