pts/1 h1boot1 ~ # ssh h1seih23 Last login: Fri Oct 19 10:26:30 PDT 2018 from h1boot1 on ssh h1seih23 ~ # cat /proc/h1iopseih23/status startGpsTime=1223992537 uptime=43137 cpuTimeEverMax=11 cpuTimeEverMaxWhen=600 adcHoldTime=14 adcHoldTimeEverMax=18 adcHoldTimeEverMaxWhen=1224000994 adcHoldTimeMax=16 adcHoldTimeMin=13 adcHoldTimeAvg=14 usrTime=1 usrHoldTime=2 cycle=27554 gps=1224035674 buildDate=Sep 17 2018 22:00:28 cpuTimeMax(cur,past sec)=3,6 cpuTimeMaxCycle(cur,past sec)=21,0 cycleHist: 3=65466@17 4=68@65535 5=1@1 6=1@0 DAC #0 16-bit fifo_status=3 (empty) DAC #1 16-bit fifo_status=2 (OK) ADC #0 read time MAX=17 Current=14 ADC #1 read time MAX=1 Current=0 ADC #2 read time MAX=0 Current=0 ADC #3 read time MAX=0 Current=0 ADC #4 read time MAX=0 Current=0 ADC #5 read time MAX=0 Current=0 ipcErrBits=0x0 h1seih23 ~ # dmesg |tail [2650410.010452] h1isiham3: IPC Name = H1:ISI-HAM3_SUSPOINT_MC2_L_OUT_IPC 40 ffffc90019900380 ffffc900199fc388 [2650410.010453] h1isiham3: IPC Name = H1:ISI-HAM3_SUSPOINT_PR2_L_OUT_IPC 41 ffffc90019900390 ffffc900199fc398 [2650410.010460] h1isiham3: Setting card local=0 global = 1 channel=8 dac usage [2650410.010461] h1isiham3: Setting card local=0 global = 1 channel=9 dac usage [2650410.010463] h1isiham3: Setting card local=0 global = 1 channel=10 dac usage [2650410.010464] h1isiham3: Setting card local=0 global = 1 channel=11 dac usage [2650410.010465] h1isiham3: Setting card local=0 global = 1 channel=12 dac usage [2650410.010467] h1isiham3: Setting card local=0 global = 1 channel=13 dac usage [2650410.010468] h1isiham3: waiting to sync 42880 [2650410.355348] h1isiham3: Synched 345136 h1seih23 ~ # exit logout Connection to h1seih23 closed. h1boot1 ~ # ssh h1seih45 Last login: Fri Oct 19 10:30:40 PDT 2018 from h1boot1 on ssh h1seih45 ~ # cat /proc/h1iopseih45/status startGpsTime=1223992577 uptime=43194 cpuTimeEverMax=9 cpuTimeEverMaxWhen=600 adcHoldTime=15 adcHoldTimeEverMax=18 adcHoldTimeEverMaxWhen=1223994094 adcHoldTimeMax=16 adcHoldTimeMin=12 adcHoldTimeAvg=14 usrTime=1 usrHoldTime=2 cycle=39336 gps=1224035771 buildDate=Sep 17 2018 22:03:03 cpuTimeMax(cur,past sec)=3,6 cpuTimeMaxCycle(cur,past sec)=21,0 cycleHist: 3=65472@17 4=62@65535 5=1@1 6=1@0 DAC #0 16-bit fifo_status=3 (empty) DAC #1 16-bit fifo_status=2 (OK) ADC #0 read time MAX=17 Current=14 ADC #1 read time MAX=2 Current=0 ADC #2 read time MAX=1 Current=0 ADC #3 read time MAX=0 Current=0 ADC #4 read time MAX=0 Current=0 ADC #5 read time MAX=0 Current=0 ipcErrBits=0x0 h1seih45 ~ # dmesg|tail [2650453.260744] h1isiham5: IPC Name = H1:ISI-HAM5_SUSPOINT_SRM_L_OUT_IPC 61 ffffc900199004d0 ffffc900199fc4d8 [2650453.260745] h1isiham5: IPC Name = H1:ISI-HAM5_SUSPOINT_ZM2_L_OUT_IPC 62 ffffc900199004e0 ffffc900199fc4e8 [2650453.260750] h1isiham5: Setting card local=0 global = 1 channel=8 dac usage [2650453.260751] h1isiham5: Setting card local=0 global = 1 channel=9 dac usage [2650453.260752] h1isiham5: Setting card local=0 global = 1 channel=10 dac usage [2650453.260753] h1isiham5: Setting card local=0 global = 1 channel=11 dac usage [2650453.260755] h1isiham5: Setting card local=0 global = 1 channel=12 dac usage [2650453.260756] h1isiham5: Setting card local=0 global = 1 channel=13 dac usage [2650453.260757] h1isiham5: waiting to sync 36928 [2650453.696828] h1isiham5: Synched 436395 h1seih45 ~ # exit logout Connection to h1seih45 closed. h1boot1 ~ #