ETMX - Accepting lower bias voltage - latest A2L DRIVEALIGN gains - 20 bit DAC filter in ESDOUTF bank - Moving the bias voltage into rampable OFFSET of DC bias bank instead of separate INBIAS EPICs record, accepted the lower bias of 9.3 instead of 9.5 because 20 bit DAC saturates at lower voltage value. - Violin mode matrix 02_20 from 1.0 set to zero (controlled by guardian?) - accepting latest alignment offsets ETMY - latest A2L gains - reverted UIM and PUM calibation line clock gains to turn them ON - accepted violin mode matrices 2_6 (from 0 to 1) and 3_6 (from 1 to 0) - ISCINF L decimation was off, reverted to ON - accepted FM2 of violin damp mode 1 - accepting the turn OFF of O2 distribution filters in L3 DRIVEALIGN L2L - accepting ISCINF L and DRIVEALIGN L3 L gains set to 1 (must be related to attempting feed forward on the ETMs) ITMX - L2L drivalign gain reverted from -91 to 0 (done during LOW_NOISE_ETMX_ESD stage of lock aquitision) - L3_LOCK_L gain is at 1, reverting zero (controlled by guardian, I think) - L2_LOCK_L input is ON. Reverting to OFF. (used in DRMI LSC feed-forward, but looking to change this to ETMs) - Violin notches in ISCINF bank reverted to ON - Lock gain set to zero (likely controlled by transition from ETMX > ITMX > ETMX) - latest A2L gains - Violin mode mode matrix gains from 1.0 to zero (controled by guardian?) - ISCINF violin notched turned OFF (moved to MICH? see LHO aLOG 45036) - latest alignment offsets ITMY - accepting latest A2L drivalign gains - accepting violin mode matrix 2_11 from 0.0 to 1.0 - accepting turning on mode 11, and several phase tuning filters. - revertin ITMY ESD bias voltage ramp from 60 to 30 - accepting ITMY ESD LOCK L ramp of 1 sec - accepting latest alignment offsets. BS - accepted latest alignment offsets TMSX - accepted latest alignment offsets TMSY - accepted latest alignment offsets SUS IMs - accepted latest alignment offsets (IM1, IM2, IM3, IM4) SUS OMC - accepted latest alignment offsets (OMC, OM1, OM2, OM3) SRM - accepted latest alignment offsets SR3 - accepted latest alignment offsets SR2 - accepted latest alignment offsets PRM - accepted latest alignment offsets PR2 - accepted latest alignment offsets PR3 - accepted latest alignment offsets MC1 - Reverting M1 tramps from 2 to 10 secs - accepted latest alignment offsets MC2 - accepted latest alignment offsets MC3 - Reverting M1 tramps from 2 to 10 secs - accepted latest alignment offsets SUS HTTS - accepted latest alignment offsets (RM1 RM2)