"4395A REV1.12" "DATE: Jul 30 2019" "CHANNEL: 1" "MEASURE TYPE: A/R" "FORMAT TYPE: LOG MAG" "NUMBER of POINTS: 801" "SWEEP TIME: 47.23 s" "SWEEP TYPE: LOG FREQ" "SOURCE POWER: -20 dBm" "IF BANDWIDTH: 100 Hz" "Frequency" "Data Trace Real" "Data Trace Imag" "Memory Trace Real" "Memory Trace Imag" 1.000000000000E+03 3.358474E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.009991000000E+03 4.187819E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.019981000000E+03 3.644297E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.029972000000E+03 3.627631E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.039962000000E+03 3.815927E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.049953000000E+03 3.570232E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.059943000000E+03 3.936891E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.069934000000E+03 4.672989E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.079925000000E+03 3.928084E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.089915000000E+03 3.761012E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.099906000000E+03 3.632704E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.109896000000E+03 3.648750E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.119887000000E+03 3.984605E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.129877000000E+03 3.561785E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.139868000000E+03 4.525164E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.149859000000E+03 3.633480E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.159849000000E+03 4.482966E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.169840000000E+03 3.674482E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.179830000000E+03 3.456261E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.189821000000E+03 3.668633E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.199812000000E+03 3.996376E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.209802000000E+03 4.500324E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.219793000000E+03 3.991943E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.229783000000E+03 3.692572E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.239774000000E+03 3.181767E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.249764000000E+03 4.024118E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.259755000000E+03 3.946608E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.269746000000E+03 4.187793E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.279736000000E+03 4.454505E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.289727000000E+03 3.471049E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.299717000000E+03 4.218490E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.309708000000E+03 3.009647E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.319698000000E+03 3.658706E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.329689000000E+03 4.161224E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.341220000000E+03 3.781786E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.354559000000E+03 3.519504E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.367898000000E+03 3.530490E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.381237000000E+03 3.407373E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.394577000000E+03 3.363328E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.407916000000E+03 3.740400E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.421255000000E+03 3.397058E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.434594000000E+03 4.262398E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.447933000000E+03 6.587093E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.461272000000E+03 3.853868E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.474611000000E+03 4.824932E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.487950000000E+03 3.644251E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.501290000000E+03 3.863567E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.514629000000E+03 4.095721E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.527968000000E+03 3.960809E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.541307000000E+03 3.992523E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.554646000000E+03 4.651798E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.567985000000E+03 3.958680E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.581324000000E+03 3.690637E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.594663000000E+03 4.016538E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.608003000000E+03 4.901321E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.621342000000E+03 3.488891E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.634681000000E+03 4.071204E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.648020000000E+03 3.698997E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.661359000000E+03 4.846908E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.674698000000E+03 5.183764E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.688037000000E+03 4.708788E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.701376000000E+03 4.072691E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.714716000000E+03 4.139479E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.728055000000E+03 3.901242E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.741394000000E+03 3.686701E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.754733000000E+03 3.923072E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.768072000000E+03 3.628225E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.783405000000E+03 3.959402E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.801142000000E+03 3.641086E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.818879000000E+03 3.889075E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.836616000000E+03 4.133564E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.854353000000E+03 5.738476E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.872090000000E+03 3.756706E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.889826000000E+03 4.318764E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.907563000000E+03 4.238972E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.925300000000E+03 4.200865E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.943037000000E+03 4.438626E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.960774000000E+03 3.533281E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.978511000000E+03 4.409498E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.996248000000E+03 3.420187E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.013985000000E+03 3.474578E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.031722000000E+03 3.517401E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.049459000000E+03 3.620480E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.067196000000E+03 3.632315E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.084932000000E+03 4.441006E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.102669000000E+03 3.951640E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.120406000000E+03 3.771877E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.138143000000E+03 3.888089E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.155880000000E+03 3.989669E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.173617000000E+03 4.127769E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.191354000000E+03 3.327848E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.209091000000E+03 3.448603E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.226828000000E+03 4.212127E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.244565000000E+03 3.190639E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.262301000000E+03 3.497979E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.280038000000E+03 3.510650E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.297775000000E+03 3.352797E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.315512000000E+03 3.805108E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.333249000000E+03 4.667936E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.350986000000E+03 5.131861E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.371374000000E+03 3.702011E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.395065000000E+03 3.903909E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.418757000000E+03 4.017966E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.442448000000E+03 3.189330E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.466139000000E+03 5.184582E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.489831000000E+03 4.379616E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.513522000000E+03 3.613022E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.537214000000E+03 3.873720E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.560905000000E+03 5.835779E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.584596000000E+03 4.200769E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.608288000000E+03 3.785917E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.631979000000E+03 4.256665E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.655670000000E+03 4.820061E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.679362000000E+03 4.961415E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.703053000000E+03 3.768915E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.726744000000E+03 4.059621E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.750436000000E+03 4.001076E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.774127000000E+03 3.470609E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.797819000000E+03 3.927771E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.821510000000E+03 4.585603E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.845201000000E+03 3.843937E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.868893000000E+03 3.361299E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.892584000000E+03 3.886559E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.916275000000E+03 3.857124E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.939967000000E+03 3.384327E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.963658000000E+03 5.269847E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.987349000000E+03 3.744176E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.011041000000E+03 3.708169E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.034732000000E+03 4.013771E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.058424000000E+03 4.974805E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.082115000000E+03 4.293787E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.105806000000E+03 3.230727E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.129498000000E+03 4.162138E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.153189000000E+03 3.898997E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.180534000000E+03 3.257317E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.212166000000E+03 3.550222E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.243798000000E+03 4.163351E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.275430000000E+03 4.263243E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.307062000000E+03 4.104799E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.338694000000E+03 3.667431E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.370326000000E+03 4.441784E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.401958000000E+03 4.234021E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.433591000000E+03 5.292103E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.465223000000E+03 3.937029E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.496855000000E+03 4.751858E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.528487000000E+03 3.736520E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.560119000000E+03 3.691313E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.591751000000E+03 4.057989E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.623383000000E+03 3.833583E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.655015000000E+03 3.786927E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.686647000000E+03 5.464633E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.718279000000E+03 3.966212E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.749911000000E+03 3.974996E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.781543000000E+03 4.492148E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.813175000000E+03 5.294532E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.844807000000E+03 3.517913E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.876439000000E+03 3.901833E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.908071000000E+03 3.501992E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.939704000000E+03 4.202139E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.971336000000E+03 4.229820E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.002968000000E+03 3.984008E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.034600000000E+03 4.993235E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.066232000000E+03 3.730235E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.097864000000E+03 3.807793E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.129496000000E+03 3.780985E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.161128000000E+03 3.813773E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.192760000000E+03 4.040756E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.229120000000E+03 4.294724E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.271181000000E+03 4.121154E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.313242000000E+03 3.858325E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.355302000000E+03 3.501336E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.397363000000E+03 3.885152E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.439424000000E+03 4.106160E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.481485000000E+03 3.813216E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.523546000000E+03 3.828298E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.565607000000E+03 4.288013E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.607667000000E+03 4.173119E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.649728000000E+03 4.384353E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.691789000000E+03 3.672637E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.733850000000E+03 4.377934E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.775911000000E+03 4.990200E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.817971000000E+03 3.983818E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.860032000000E+03 3.497588E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.902093000000E+03 3.803330E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.944154000000E+03 3.773610E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.986215000000E+03 4.430502E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.028275000000E+03 4.594107E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.070336000000E+03 3.597160E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.112397000000E+03 4.549972E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.154458000000E+03 4.464623E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.196519000000E+03 3.579564E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.238580000000E+03 6.149498E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.280640000000E+03 4.015201E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.322701000000E+03 3.786814E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.364762000000E+03 4.201370E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.406823000000E+03 4.700276E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.448884000000E+03 4.133773E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.490944000000E+03 4.683830E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.533005000000E+03 3.910785E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.575066000000E+03 4.500460E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.623413000000E+03 3.824615E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.679594000000E+03 3.469532E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.735775000000E+03 3.471778E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.791956000000E+03 4.019319E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.848137000000E+03 4.198141E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.904318000000E+03 3.746621E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.960500000000E+03 3.974033E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.016681000000E+03 4.441152E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.072862000000E+03 3.492169E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.129043000000E+03 3.976909E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.185224000000E+03 4.247612E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.241405000000E+03 3.884713E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.297586000000E+03 4.849037E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.353767000000E+03 3.893438E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.409948000000E+03 3.866869E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.466129000000E+03 3.621166E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.522310000000E+03 3.802675E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.578492000000E+03 3.940929E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.634673000000E+03 5.350590E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.690854000000E+03 3.945594E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.747035000000E+03 5.633356E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.803216000000E+03 3.582079E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.859397000000E+03 4.016581E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.915578000000E+03 4.322612E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.971759000000E+03 4.043803E+01 0.000000E+00 0.000000E+00 0.000000E+00 7.027940000000E+03 3.590527E+01 0.000000E+00 0.000000E+00 0.000000E+00 7.084121000000E+03 3.561662E+01 0.000000E+00 0.000000E+00 0.000000E+00 7.140302000000E+03 3.538821E+01 0.000000E+00 0.000000E+00 0.000000E+00 7.196484000000E+03 3.810297E+01 0.000000E+00 0.000000E+00 0.000000E+00 7.252665000000E+03 3.893868E+01 0.000000E+00 0.000000E+00 0.000000E+00 7.308846000000E+03 3.433108E+01 0.000000E+00 0.000000E+00 0.000000E+00 7.365027000000E+03 4.225680E+01 0.000000E+00 0.000000E+00 0.000000E+00 7.421208000000E+03 3.401930E+01 0.000000E+00 0.000000E+00 0.000000E+00 7.477389000000E+03 3.778876E+01 0.000000E+00 0.000000E+00 0.000000E+00 7.542234000000E+03 4.488388E+01 0.000000E+00 0.000000E+00 0.000000E+00 7.617245000000E+03 3.923085E+01 0.000000E+00 0.000000E+00 0.000000E+00 7.692257000000E+03 5.540876E+01 0.000000E+00 0.000000E+00 0.000000E+00 7.767268000000E+03 4.704940E+01 0.000000E+00 0.000000E+00 0.000000E+00 7.842280000000E+03 4.530134E+01 0.000000E+00 0.000000E+00 0.000000E+00 7.917291000000E+03 4.528269E+01 0.000000E+00 0.000000E+00 0.000000E+00 7.992303000000E+03 4.355838E+01 0.000000E+00 0.000000E+00 0.000000E+00 8.067314000000E+03 5.191728E+01 0.000000E+00 0.000000E+00 0.000000E+00 8.142326000000E+03 4.104807E+01 0.000000E+00 0.000000E+00 0.000000E+00 8.217337000000E+03 4.114790E+01 0.000000E+00 0.000000E+00 0.000000E+00 8.292349000000E+03 4.279549E+01 0.000000E+00 0.000000E+00 0.000000E+00 8.367360000000E+03 3.624060E+01 0.000000E+00 0.000000E+00 0.000000E+00 8.442372000000E+03 4.036399E+01 0.000000E+00 0.000000E+00 0.000000E+00 8.517383000000E+03 4.183655E+01 0.000000E+00 0.000000E+00 0.000000E+00 8.592395000000E+03 3.871791E+01 0.000000E+00 0.000000E+00 0.000000E+00 8.667406000000E+03 4.931709E+01 0.000000E+00 0.000000E+00 0.000000E+00 8.742418000000E+03 4.472916E+01 0.000000E+00 0.000000E+00 0.000000E+00 8.817429000000E+03 4.769249E+01 0.000000E+00 0.000000E+00 0.000000E+00 8.892440000000E+03 4.421161E+01 0.000000E+00 0.000000E+00 0.000000E+00 8.967452000000E+03 4.536618E+01 0.000000E+00 0.000000E+00 0.000000E+00 9.042463000000E+03 4.798357E+01 0.000000E+00 0.000000E+00 0.000000E+00 9.117475000000E+03 5.877792E+01 0.000000E+00 0.000000E+00 0.000000E+00 9.192486000000E+03 5.020563E+01 0.000000E+00 0.000000E+00 0.000000E+00 9.267498000000E+03 4.135721E+01 0.000000E+00 0.000000E+00 0.000000E+00 9.342509000000E+03 4.154839E+01 0.000000E+00 0.000000E+00 0.000000E+00 9.417521000000E+03 4.546546E+01 0.000000E+00 0.000000E+00 0.000000E+00 9.492532000000E+03 5.928102E+01 0.000000E+00 0.000000E+00 0.000000E+00 9.567544000000E+03 4.048893E+01 0.000000E+00 0.000000E+00 0.000000E+00 9.642555000000E+03 4.494390E+01 0.000000E+00 0.000000E+00 0.000000E+00 9.717567000000E+03 4.286353E+01 0.000000E+00 0.000000E+00 0.000000E+00 9.792578000000E+03 4.713507E+01 0.000000E+00 0.000000E+00 0.000000E+00 9.867590000000E+03 4.415506E+01 0.000000E+00 0.000000E+00 0.000000E+00 9.942601000000E+03 5.069134E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.002882400000E+04 4.207214E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.012856600000E+04 4.412285E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.022830800000E+04 4.144586E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.032805000000E+04 3.835077E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.042779200000E+04 4.150248E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.052753400000E+04 3.889041E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.062727500000E+04 4.023021E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.072701700000E+04 4.670745E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.082675900000E+04 4.040947E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.092650100000E+04 5.022507E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.102624300000E+04 5.225405E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.112598500000E+04 4.444662E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.122572700000E+04 5.607240E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.132546900000E+04 4.364995E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.142521100000E+04 5.004314E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.152495300000E+04 4.203175E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.162469500000E+04 4.498718E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.172443600000E+04 4.010486E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.182417800000E+04 4.269921E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.192392000000E+04 4.602596E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.202366200000E+04 4.189224E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.212340400000E+04 4.464660E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.222314600000E+04 4.935817E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.232288800000E+04 4.269979E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.242263000000E+04 4.157454E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.252237200000E+04 4.335117E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.262211400000E+04 4.380356E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.272185500000E+04 4.277173E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.282159700000E+04 4.285027E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.292133900000E+04 4.376911E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.302108100000E+04 4.059060E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.312082300000E+04 4.183777E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.322056500000E+04 4.664404E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.333521400000E+04 4.199995E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.346844000000E+04 4.710190E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.360166700000E+04 3.922609E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.373489300000E+04 4.297658E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.386812000000E+04 5.149109E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.400134600000E+04 4.124451E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.413457200000E+04 4.787318E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.426779900000E+04 5.046058E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.440102500000E+04 4.787441E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.453425200000E+04 4.537458E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.466747800000E+04 4.643404E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.480070400000E+04 4.939487E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.493393100000E+04 5.042131E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.506715700000E+04 4.093837E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.520038400000E+04 4.509148E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.533361000000E+04 3.810406E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.546683600000E+04 4.344193E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.560006300000E+04 4.255408E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.573328900000E+04 3.570835E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.586651500000E+04 4.311998E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.599974200000E+04 5.041003E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.613296800000E+04 5.041545E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.626619500000E+04 4.333483E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.639942100000E+04 4.920921E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.653264700000E+04 5.553386E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.666587400000E+04 3.996240E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.679910000000E+04 5.200966E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.693232700000E+04 4.486278E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.706555300000E+04 4.414390E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.719877900000E+04 4.261140E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.733200600000E+04 5.390607E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.746523200000E+04 4.696756E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.759845900000E+04 3.926683E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.773168500000E+04 5.245832E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.788545500000E+04 4.061126E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.806333500000E+04 4.209808E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.824121500000E+04 3.952235E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.841909600000E+04 3.836987E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.859697600000E+04 3.607303E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.877485600000E+04 3.708057E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.895273600000E+04 3.535618E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.913061700000E+04 3.515517E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.930849700000E+04 3.414391E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.948637700000E+04 3.567215E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.966425700000E+04 3.317358E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.984213700000E+04 3.624968E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.002001800000E+04 3.232844E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.019789800000E+04 3.174762E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.037577800000E+04 3.061700E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.055365800000E+04 2.911988E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.073153900000E+04 3.037480E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.090941900000E+04 3.172461E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.108729900000E+04 2.891973E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.126517900000E+04 2.812714E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.144305900000E+04 2.880379E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.162094000000E+04 2.946786E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.179882000000E+04 2.788209E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.197670000000E+04 2.614664E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.215458000000E+04 2.742203E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.233246000000E+04 2.637325E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.251034100000E+04 2.657143E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.268822100000E+04 2.471946E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.286610100000E+04 2.583781E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.304398100000E+04 2.657093E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.322186200000E+04 2.439644E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.339974200000E+04 2.628051E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.357762200000E+04 2.442479E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.378208900000E+04 2.409215E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.401861400000E+04 2.498046E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.425514000000E+04 2.436548E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.449166500000E+04 2.312571E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.472819000000E+04 2.473233E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.496471600000E+04 2.379388E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.520124100000E+04 2.315635E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.543776600000E+04 2.392499E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.567429200000E+04 2.440100E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.591081700000E+04 2.462496E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.614734200000E+04 2.445455E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.638386700000E+04 2.523450E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.662039300000E+04 2.570044E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.685691800000E+04 2.449618E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.709344300000E+04 2.591636E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.732996900000E+04 2.532826E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.756649400000E+04 2.489524E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.780301900000E+04 2.615145E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.803954500000E+04 2.544818E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.827607000000E+04 2.571752E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.851259500000E+04 2.603577E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.874912100000E+04 2.586567E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.898564600000E+04 2.648333E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.922217100000E+04 2.518550E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.945869700000E+04 2.598794E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.969522200000E+04 2.541285E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.993174700000E+04 2.546475E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.016827200000E+04 2.541988E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.040479800000E+04 2.507560E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.064132300000E+04 2.545929E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.087784800000E+04 2.545505E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.111437400000E+04 2.540689E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.135089900000E+04 2.486425E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.162277700000E+04 2.534341E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.193870700000E+04 2.568249E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.225463600000E+04 2.577291E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.257056600000E+04 2.515677E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.288649500000E+04 2.579597E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.320242500000E+04 2.545503E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.351835400000E+04 2.477543E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.383428400000E+04 2.479857E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.415021300000E+04 2.491096E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.446614300000E+04 2.470038E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.478207200000E+04 2.433223E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.509800200000E+04 2.525955E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.541393100000E+04 2.466493E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.572986100000E+04 2.440932E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.604579000000E+04 2.465604E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.636172000000E+04 2.528678E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.667764900000E+04 2.428096E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.699357900000E+04 2.337517E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.730950800000E+04 2.397755E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.762543800000E+04 2.355641E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.794136700000E+04 2.345332E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.825729700000E+04 2.346307E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.857322600000E+04 2.368944E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.888915600000E+04 2.351028E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.920508500000E+04 2.399932E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.952101500000E+04 2.353394E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.983694400000E+04 2.302238E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.015287400000E+04 2.344896E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.046880300000E+04 2.323952E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.078473300000E+04 2.209386E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.110066200000E+04 2.277055E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.141659200000E+04 2.288545E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.173252100000E+04 2.277420E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.204845100000E+04 2.197827E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.241309800000E+04 2.181858E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.283491800000E+04 2.170468E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.325673900000E+04 2.157858E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.367855900000E+04 2.137347E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.410038000000E+04 2.118016E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.452220000000E+04 2.087391E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.494402100000E+04 2.076169E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.536584100000E+04 2.014895E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.578766200000E+04 2.079339E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.620948200000E+04 2.005019E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.663130300000E+04 2.062170E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.705312300000E+04 1.979317E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.747494400000E+04 1.963772E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.789676400000E+04 2.002466E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.831858500000E+04 1.960142E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.874040500000E+04 1.951110E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.916222600000E+04 1.897698E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.958404600000E+04 1.930322E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.000586600000E+04 1.848927E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.042768700000E+04 1.842117E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.084950700000E+04 1.855501E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.127132800000E+04 1.825553E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.169314800000E+04 1.848833E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.211496900000E+04 1.780360E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.253678900000E+04 1.796801E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.295861000000E+04 1.758099E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.338043000000E+04 1.715528E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.380225100000E+04 1.741114E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.422407100000E+04 1.734109E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.464589200000E+04 1.704061E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.506771200000E+04 1.730720E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.548953300000E+04 1.691157E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.591135300000E+04 1.653407E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.639622100000E+04 1.644186E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.695711100000E+04 1.601624E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.751800100000E+04 1.551071E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.807889100000E+04 1.573576E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.863978100000E+04 1.534619E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.920067100000E+04 1.477137E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.976156000000E+04 1.515794E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.032245000000E+04 1.490748E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.088334000000E+04 1.462007E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.144423000000E+04 1.458514E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.200512000000E+04 1.448471E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.256601000000E+04 1.416978E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.312690000000E+04 1.385663E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.368779000000E+04 1.375861E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.424868000000E+04 1.351006E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.480957000000E+04 1.348465E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.537046000000E+04 1.307266E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.593134900000E+04 1.286618E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.649223900000E+04 1.281375E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.705312900000E+04 1.273426E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.761401900000E+04 1.228400E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.817490900000E+04 1.220593E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.873579900000E+04 1.218621E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.929668900000E+04 1.213299E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.985757900000E+04 1.168324E+01 0.000000E+00 0.000000E+00 0.000000E+00 7.041846900000E+04 1.157413E+01 0.000000E+00 0.000000E+00 0.000000E+00 7.097935900000E+04 1.147501E+01 0.000000E+00 0.000000E+00 0.000000E+00 7.154024800000E+04 1.120286E+01 0.000000E+00 0.000000E+00 0.000000E+00 7.210113800000E+04 1.138771E+01 0.000000E+00 0.000000E+00 0.000000E+00 7.266202800000E+04 1.111784E+01 0.000000E+00 0.000000E+00 0.000000E+00 7.322291800000E+04 1.069082E+01 0.000000E+00 0.000000E+00 0.000000E+00 7.378380800000E+04 1.063299E+01 0.000000E+00 0.000000E+00 0.000000E+00 7.434469800000E+04 1.040892E+01 0.000000E+00 0.000000E+00 0.000000E+00 7.498942100000E+04 1.022143E+01 0.000000E+00 0.000000E+00 0.000000E+00 7.573860800000E+04 1.007453E+01 0.000000E+00 0.000000E+00 0.000000E+00 7.648779500000E+04 9.786540E+00 0.000000E+00 0.000000E+00 0.000000E+00 7.723698200000E+04 9.792793E+00 0.000000E+00 0.000000E+00 0.000000E+00 7.798616900000E+04 9.664831E+00 0.000000E+00 0.000000E+00 0.000000E+00 7.873535600000E+04 9.508204E+00 0.000000E+00 0.000000E+00 0.000000E+00 7.948454300000E+04 9.105919E+00 0.000000E+00 0.000000E+00 0.000000E+00 8.023373000000E+04 8.923097E+00 0.000000E+00 0.000000E+00 0.000000E+00 8.098291700000E+04 8.567611E+00 0.000000E+00 0.000000E+00 0.000000E+00 8.173210400000E+04 8.364490E+00 0.000000E+00 0.000000E+00 0.000000E+00 8.248129100000E+04 8.363505E+00 0.000000E+00 0.000000E+00 0.000000E+00 8.323047800000E+04 8.246366E+00 0.000000E+00 0.000000E+00 0.000000E+00 8.397966500000E+04 8.028214E+00 0.000000E+00 0.000000E+00 0.000000E+00 8.472885200000E+04 7.911836E+00 0.000000E+00 0.000000E+00 0.000000E+00 8.547803900000E+04 7.601622E+00 0.000000E+00 0.000000E+00 0.000000E+00 8.622722600000E+04 7.456774E+00 0.000000E+00 0.000000E+00 0.000000E+00 8.697641300000E+04 7.260653E+00 0.000000E+00 0.000000E+00 0.000000E+00 8.772559900000E+04 7.144703E+00 0.000000E+00 0.000000E+00 0.000000E+00 8.847478600000E+04 7.018668E+00 0.000000E+00 0.000000E+00 0.000000E+00 8.922397300000E+04 6.851475E+00 0.000000E+00 0.000000E+00 0.000000E+00 8.997316000000E+04 6.633250E+00 0.000000E+00 0.000000E+00 0.000000E+00 9.072234700000E+04 6.618249E+00 0.000000E+00 0.000000E+00 0.000000E+00 9.147153400000E+04 6.335300E+00 0.000000E+00 0.000000E+00 0.000000E+00 9.222072100000E+04 6.114187E+00 0.000000E+00 0.000000E+00 0.000000E+00 9.296990800000E+04 6.071683E+00 0.000000E+00 0.000000E+00 0.000000E+00 9.371909500000E+04 6.008150E+00 0.000000E+00 0.000000E+00 0.000000E+00 9.446828200000E+04 5.688461E+00 0.000000E+00 0.000000E+00 0.000000E+00 9.521746900000E+04 5.627600E+00 0.000000E+00 0.000000E+00 0.000000E+00 9.596665600000E+04 5.609375E+00 0.000000E+00 0.000000E+00 0.000000E+00 9.671584300000E+04 5.289362E+00 0.000000E+00 0.000000E+00 0.000000E+00 9.746503000000E+04 5.266540E+00 0.000000E+00 0.000000E+00 0.000000E+00 9.821421700000E+04 5.258874E+00 0.000000E+00 0.000000E+00 0.000000E+00 9.896340400000E+04 5.195169E+00 0.000000E+00 0.000000E+00 0.000000E+00 9.971259100000E+04 5.259688E+00 0.000000E+00 0.000000E+00 0.000000E+00 1.005773060000E+05 4.639144E+00 0.000000E+00 0.000000E+00 0.000000E+00 1.015776000000E+05 4.172076E+00 0.000000E+00 0.000000E+00 0.000000E+00 1.025778940000E+05 3.837515E+00 0.000000E+00 0.000000E+00 0.000000E+00 1.035781880000E+05 3.629276E+00 0.000000E+00 0.000000E+00 0.000000E+00 1.045784820000E+05 3.523772E+00 0.000000E+00 0.000000E+00 0.000000E+00 1.055787760000E+05 3.436456E+00 0.000000E+00 0.000000E+00 0.000000E+00 1.065790700000E+05 3.295933E+00 0.000000E+00 0.000000E+00 0.000000E+00 1.075793640000E+05 3.372174E+00 0.000000E+00 0.000000E+00 0.000000E+00 1.085796580000E+05 3.018199E+00 0.000000E+00 0.000000E+00 0.000000E+00 1.095799510000E+05 2.976655E+00 0.000000E+00 0.000000E+00 0.000000E+00 1.105802450000E+05 2.774661E+00 0.000000E+00 0.000000E+00 0.000000E+00 1.115805390000E+05 2.670067E+00 0.000000E+00 0.000000E+00 0.000000E+00 1.125808330000E+05 2.342401E+00 0.000000E+00 0.000000E+00 0.000000E+00 1.135811270000E+05 2.284667E+00 0.000000E+00 0.000000E+00 0.000000E+00 1.145814210000E+05 2.269408E+00 0.000000E+00 0.000000E+00 0.000000E+00 1.155817150000E+05 2.149364E+00 0.000000E+00 0.000000E+00 0.000000E+00 1.165820090000E+05 1.910923E+00 0.000000E+00 0.000000E+00 0.000000E+00 1.175823030000E+05 1.854962E+00 0.000000E+00 0.000000E+00 0.000000E+00 1.185825970000E+05 1.690519E+00 0.000000E+00 0.000000E+00 0.000000E+00 1.195828910000E+05 1.690338E+00 0.000000E+00 0.000000E+00 0.000000E+00 1.205831850000E+05 1.342290E+00 0.000000E+00 0.000000E+00 0.000000E+00 1.215834790000E+05 1.281779E+00 0.000000E+00 0.000000E+00 0.000000E+00 1.225837730000E+05 1.183562E+00 0.000000E+00 0.000000E+00 0.000000E+00 1.235840670000E+05 1.043342E+00 0.000000E+00 0.000000E+00 0.000000E+00 1.245843610000E+05 9.391483E-01 0.000000E+00 0.000000E+00 0.000000E+00 1.255846540000E+05 8.347183E-01 0.000000E+00 0.000000E+00 0.000000E+00 1.265849480000E+05 6.908677E-01 0.000000E+00 0.000000E+00 0.000000E+00 1.275852420000E+05 5.407394E-01 0.000000E+00 0.000000E+00 0.000000E+00 1.285855360000E+05 2.910341E-01 0.000000E+00 0.000000E+00 0.000000E+00 1.295858300000E+05 2.561065E-01 0.000000E+00 0.000000E+00 0.000000E+00 1.305861240000E+05 2.178676E-01 0.000000E+00 0.000000E+00 0.000000E+00 1.315864180000E+05 7.267233E-01 0.000000E+00 0.000000E+00 0.000000E+00 1.325867120000E+05 7.002780E-01 0.000000E+00 0.000000E+00 0.000000E+00 1.337365140000E+05 4.863270E-01 0.000000E+00 0.000000E+00 0.000000E+00 1.350665940000E+05 2.932419E-01 0.000000E+00 0.000000E+00 0.000000E+00 1.363966730000E+05 1.467845E-01 0.000000E+00 0.000000E+00 0.000000E+00 1.377267530000E+05 2.150995E-01 0.000000E+00 0.000000E+00 0.000000E+00 1.390568320000E+05 1.113223E-01 0.000000E+00 0.000000E+00 0.000000E+00 1.403869120000E+05 1.399436E-01 0.000000E+00 0.000000E+00 0.000000E+00 1.417169920000E+05 2.411056E-01 0.000000E+00 0.000000E+00 0.000000E+00 1.430470710000E+05 2.700016E-01 0.000000E+00 0.000000E+00 0.000000E+00 1.443771510000E+05 2.549199E-01 0.000000E+00 0.000000E+00 0.000000E+00 1.457072300000E+05 4.503927E-01 0.000000E+00 0.000000E+00 0.000000E+00 1.470373100000E+05 5.512981E-01 0.000000E+00 0.000000E+00 0.000000E+00 1.483673900000E+05 6.843004E-01 0.000000E+00 0.000000E+00 0.000000E+00 1.496974690000E+05 8.705642E-01 0.000000E+00 0.000000E+00 0.000000E+00 1.510275490000E+05 3.296694E-01 0.000000E+00 0.000000E+00 0.000000E+00 1.523576280000E+05 -1.455641E+00 0.000000E+00 0.000000E+00 0.000000E+00 1.536877080000E+05 -5.494421E+00 0.000000E+00 0.000000E+00 0.000000E+00 1.550177880000E+05 -5.617913E+00 0.000000E+00 0.000000E+00 0.000000E+00 1.563478670000E+05 -4.726921E+00 0.000000E+00 0.000000E+00 0.000000E+00 1.576779470000E+05 -4.152002E+00 0.000000E+00 0.000000E+00 0.000000E+00 1.590080260000E+05 -3.831615E+00 0.000000E+00 0.000000E+00 0.000000E+00 1.603381060000E+05 -3.545482E+00 0.000000E+00 0.000000E+00 0.000000E+00 1.616681850000E+05 -3.531705E+00 0.000000E+00 0.000000E+00 0.000000E+00 1.629982650000E+05 -3.394670E+00 0.000000E+00 0.000000E+00 0.000000E+00 1.643283450000E+05 -3.693024E+00 0.000000E+00 0.000000E+00 0.000000E+00 1.656584240000E+05 -3.547304E+00 0.000000E+00 0.000000E+00 0.000000E+00 1.669885040000E+05 -3.803544E+00 0.000000E+00 0.000000E+00 0.000000E+00 1.683185830000E+05 -4.295294E+00 0.000000E+00 0.000000E+00 0.000000E+00 1.696486630000E+05 -4.201202E+00 0.000000E+00 0.000000E+00 0.000000E+00 1.709787430000E+05 -4.450447E+00 0.000000E+00 0.000000E+00 0.000000E+00 1.723088220000E+05 -5.099546E+00 0.000000E+00 0.000000E+00 0.000000E+00 1.736389020000E+05 -6.400518E+00 0.000000E+00 0.000000E+00 0.000000E+00 1.749689810000E+05 -6.697724E+00 0.000000E+00 0.000000E+00 0.000000E+00 1.762990610000E+05 -5.966491E+00 0.000000E+00 0.000000E+00 0.000000E+00 1.778279410000E+05 -4.664641E+00 0.000000E+00 0.000000E+00 0.000000E+00 1.796045430000E+05 -4.460409E+00 0.000000E+00 0.000000E+00 0.000000E+00 1.813811460000E+05 -4.679451E+00 0.000000E+00 0.000000E+00 0.000000E+00 1.831577480000E+05 -4.680707E+00 0.000000E+00 0.000000E+00 0.000000E+00 1.849343500000E+05 -5.101787E+00 0.000000E+00 0.000000E+00 0.000000E+00 1.867109520000E+05 -5.874776E+00 0.000000E+00 0.000000E+00 0.000000E+00 1.884875550000E+05 -5.017881E+00 0.000000E+00 0.000000E+00 0.000000E+00 1.902641570000E+05 -4.966888E+00 0.000000E+00 0.000000E+00 0.000000E+00 1.920407590000E+05 -3.950814E+00 0.000000E+00 0.000000E+00 0.000000E+00 1.938173610000E+05 -4.029676E+00 0.000000E+00 0.000000E+00 0.000000E+00 1.955939640000E+05 -3.880485E+00 0.000000E+00 0.000000E+00 0.000000E+00 1.973705660000E+05 -4.434255E+00 0.000000E+00 0.000000E+00 0.000000E+00 1.991471680000E+05 -4.688124E+00 0.000000E+00 0.000000E+00 0.000000E+00 2.009237710000E+05 -5.625679E+00 0.000000E+00 0.000000E+00 0.000000E+00 2.027003730000E+05 -5.148962E+00 0.000000E+00 0.000000E+00 0.000000E+00 2.044769750000E+05 -4.771415E+00 0.000000E+00 0.000000E+00 0.000000E+00 2.062535770000E+05 -5.729377E+00 0.000000E+00 0.000000E+00 0.000000E+00 2.080301800000E+05 -6.307800E+00 0.000000E+00 0.000000E+00 0.000000E+00 2.098067820000E+05 -7.220996E+00 0.000000E+00 0.000000E+00 0.000000E+00 2.115833840000E+05 -7.255237E+00 0.000000E+00 0.000000E+00 0.000000E+00 2.133599860000E+05 -6.589758E+00 0.000000E+00 0.000000E+00 0.000000E+00 2.151365890000E+05 -7.061643E+00 0.000000E+00 0.000000E+00 0.000000E+00 2.169131910000E+05 -6.796558E+00 0.000000E+00 0.000000E+00 0.000000E+00 2.186897930000E+05 -7.218300E+00 0.000000E+00 0.000000E+00 0.000000E+00 2.204663960000E+05 -7.086810E+00 0.000000E+00 0.000000E+00 0.000000E+00 2.222429980000E+05 -6.566044E+00 0.000000E+00 0.000000E+00 0.000000E+00 2.240196000000E+05 -6.788789E+00 0.000000E+00 0.000000E+00 0.000000E+00 2.257962020000E+05 -6.885612E+00 0.000000E+00 0.000000E+00 0.000000E+00 2.275728050000E+05 -6.642635E+00 0.000000E+00 0.000000E+00 0.000000E+00 2.293494070000E+05 -6.581195E+00 0.000000E+00 0.000000E+00 0.000000E+00 2.311260090000E+05 -6.782503E+00 0.000000E+00 0.000000E+00 0.000000E+00 2.329026110000E+05 -6.822102E+00 0.000000E+00 0.000000E+00 0.000000E+00 2.346792140000E+05 -6.750770E+00 0.000000E+00 0.000000E+00 0.000000E+00 2.364558160000E+05 -6.522233E+00 0.000000E+00 0.000000E+00 0.000000E+00 2.385063800000E+05 -6.046164E+00 0.000000E+00 0.000000E+00 0.000000E+00 2.408784510000E+05 -4.298166E+00 0.000000E+00 0.000000E+00 0.000000E+00 2.432505210000E+05 -3.749862E+00 0.000000E+00 0.000000E+00 0.000000E+00 2.456225920000E+05 -5.318820E+00 0.000000E+00 0.000000E+00 0.000000E+00 2.479946630000E+05 -5.305234E+00 0.000000E+00 0.000000E+00 0.000000E+00 2.503667330000E+05 -6.098758E+00 0.000000E+00 0.000000E+00 0.000000E+00 2.527388040000E+05 -6.643691E+00 0.000000E+00 0.000000E+00 0.000000E+00 2.551108750000E+05 -6.746308E+00 0.000000E+00 0.000000E+00 0.000000E+00 2.574829460000E+05 -6.765053E+00 0.000000E+00 0.000000E+00 0.000000E+00 2.598550160000E+05 -6.335998E+00 0.000000E+00 0.000000E+00 0.000000E+00 2.622270870000E+05 -5.545580E+00 0.000000E+00 0.000000E+00 0.000000E+00 2.645991580000E+05 -4.992292E+00 0.000000E+00 0.000000E+00 0.000000E+00 2.669712280000E+05 -4.612929E+00 0.000000E+00 0.000000E+00 0.000000E+00 2.693432990000E+05 -4.774185E+00 0.000000E+00 0.000000E+00 0.000000E+00 2.717153700000E+05 -4.772422E+00 0.000000E+00 0.000000E+00 0.000000E+00 2.740874400000E+05 -5.268824E+00 0.000000E+00 0.000000E+00 0.000000E+00 2.764595110000E+05 -5.228004E+00 0.000000E+00 0.000000E+00 0.000000E+00 2.788315820000E+05 -5.396628E+00 0.000000E+00 0.000000E+00 0.000000E+00 2.812036520000E+05 -5.929716E+00 0.000000E+00 0.000000E+00 0.000000E+00 2.835757230000E+05 -6.011489E+00 0.000000E+00 0.000000E+00 0.000000E+00 2.859477940000E+05 -6.008506E+00 0.000000E+00 0.000000E+00 0.000000E+00 2.883198640000E+05 -6.128757E+00 0.000000E+00 0.000000E+00 0.000000E+00 2.906919350000E+05 -5.818779E+00 0.000000E+00 0.000000E+00 0.000000E+00 2.930640060000E+05 -5.303890E+00 0.000000E+00 0.000000E+00 0.000000E+00 2.954360770000E+05 -5.468496E+00 0.000000E+00 0.000000E+00 0.000000E+00 2.978081470000E+05 -5.900430E+00 0.000000E+00 0.000000E+00 0.000000E+00 3.001802180000E+05 -6.328559E+00 0.000000E+00 0.000000E+00 0.000000E+00 3.025522890000E+05 -6.714232E+00 0.000000E+00 0.000000E+00 0.000000E+00 3.049243590000E+05 -6.999012E+00 0.000000E+00 0.000000E+00 0.000000E+00 3.072964300000E+05 -7.037333E+00 0.000000E+00 0.000000E+00 0.000000E+00 3.096685010000E+05 -7.078398E+00 0.000000E+00 0.000000E+00 0.000000E+00 3.120405710000E+05 -7.249667E+00 0.000000E+00 0.000000E+00 0.000000E+00 3.144126420000E+05 -7.556409E+00 0.000000E+00 0.000000E+00 0.000000E+00 3.171392540000E+05 -7.861373E+00 0.000000E+00 0.000000E+00 0.000000E+00 3.202933700000E+05 -8.107238E+00 0.000000E+00 0.000000E+00 0.000000E+00 3.234474860000E+05 -8.249667E+00 0.000000E+00 0.000000E+00 0.000000E+00 3.266016010000E+05 -8.292590E+00 0.000000E+00 0.000000E+00 0.000000E+00 3.297557170000E+05 -8.310231E+00 0.000000E+00 0.000000E+00 0.000000E+00 3.329098330000E+05 -8.320411E+00 0.000000E+00 0.000000E+00 0.000000E+00 3.360639490000E+05 -8.371958E+00 0.000000E+00 0.000000E+00 0.000000E+00 3.392180640000E+05 -8.414163E+00 0.000000E+00 0.000000E+00 0.000000E+00 3.423721800000E+05 -8.580889E+00 0.000000E+00 0.000000E+00 0.000000E+00 3.455262960000E+05 -8.614905E+00 0.000000E+00 0.000000E+00 0.000000E+00 3.486804120000E+05 -8.791017E+00 0.000000E+00 0.000000E+00 0.000000E+00 3.518345270000E+05 -8.976521E+00 0.000000E+00 0.000000E+00 0.000000E+00 3.549886430000E+05 -8.903449E+00 0.000000E+00 0.000000E+00 0.000000E+00 3.581427590000E+05 -8.960232E+00 0.000000E+00 0.000000E+00 0.000000E+00 3.612968750000E+05 -8.972468E+00 0.000000E+00 0.000000E+00 0.000000E+00 3.644509900000E+05 -8.923818E+00 0.000000E+00 0.000000E+00 0.000000E+00 3.676051060000E+05 -9.131571E+00 0.000000E+00 0.000000E+00 0.000000E+00 3.707592220000E+05 -9.325478E+00 0.000000E+00 0.000000E+00 0.000000E+00 3.739133380000E+05 -9.162359E+00 0.000000E+00 0.000000E+00 0.000000E+00 3.770674530000E+05 -9.174279E+00 0.000000E+00 0.000000E+00 0.000000E+00 3.802215690000E+05 -9.326142E+00 0.000000E+00 0.000000E+00 0.000000E+00 3.833756850000E+05 -9.417896E+00 0.000000E+00 0.000000E+00 0.000000E+00 3.865298010000E+05 -9.817976E+00 0.000000E+00 0.000000E+00 0.000000E+00 3.896839160000E+05 -9.738625E+00 0.000000E+00 0.000000E+00 0.000000E+00 3.928380320000E+05 -9.641510E+00 0.000000E+00 0.000000E+00 0.000000E+00 3.959921480000E+05 -9.462385E+00 0.000000E+00 0.000000E+00 0.000000E+00 3.991462640000E+05 -9.466785E+00 0.000000E+00 0.000000E+00 0.000000E+00 4.023003790000E+05 -9.602320E+00 0.000000E+00 0.000000E+00 0.000000E+00 4.054544950000E+05 -9.711505E+00 0.000000E+00 0.000000E+00 0.000000E+00 4.086086110000E+05 -9.706347E+00 0.000000E+00 0.000000E+00 0.000000E+00 4.117627270000E+05 -9.780746E+00 0.000000E+00 0.000000E+00 0.000000E+00 4.149168420000E+05 -9.853478E+00 0.000000E+00 0.000000E+00 0.000000E+00 4.180709580000E+05 -1.005281E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.216965030000E+05 -1.002634E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.259094910000E+05 -1.013454E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.301224790000E+05 -1.019880E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.343354670000E+05 -1.021789E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.385484550000E+05 -1.039319E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.427614430000E+05 -1.051447E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.469744300000E+05 -1.054357E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.511874180000E+05 -1.057465E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.554004060000E+05 -1.056242E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.596133940000E+05 -1.060804E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.638263820000E+05 -1.070520E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.680393700000E+05 -1.086134E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.722523580000E+05 -1.086416E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.764653460000E+05 -1.092391E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.806783340000E+05 -1.098820E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.848913220000E+05 -1.105601E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.891043100000E+05 -1.111689E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.933172970000E+05 -1.121861E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.975302850000E+05 -1.106717E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.017432730000E+05 -1.111096E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.059562610000E+05 -1.117060E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.101692490000E+05 -1.122172E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.143822370000E+05 -1.129191E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.185952250000E+05 -1.137031E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.228082130000E+05 -1.152336E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.270212010000E+05 -1.150396E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.312341890000E+05 -1.156699E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.354471770000E+05 -1.196736E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.396601640000E+05 -1.175934E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.438731520000E+05 -1.194654E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.480861400000E+05 -1.181590E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.522991280000E+05 -1.186073E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.565121160000E+05 -1.192731E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.607251040000E+05 -1.202631E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.655877570000E+05 -1.209877E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.712128230000E+05 -1.217752E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.768378890000E+05 -1.225892E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.824629550000E+05 -1.226765E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.880880210000E+05 -1.245148E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.937130870000E+05 -1.246157E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.993381540000E+05 -1.244464E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.049632200000E+05 -1.239970E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.105882860000E+05 -1.260766E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.162133520000E+05 -1.268083E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.218384180000E+05 -1.277876E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.274634840000E+05 -1.275563E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.330885500000E+05 -1.282216E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.387136160000E+05 -1.296323E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.443386820000E+05 -1.306674E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.499637480000E+05 -1.310435E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.555888150000E+05 -1.307878E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.612138810000E+05 -1.306695E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.668389470000E+05 -1.308067E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.724640130000E+05 -1.326205E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.780890790000E+05 -1.335181E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.837141450000E+05 -1.352380E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.893392110000E+05 -1.347817E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.949642770000E+05 -1.342027E+01 0.000000E+00 0.000000E+00 0.000000E+00 7.005893430000E+05 -1.350820E+01 0.000000E+00 0.000000E+00 0.000000E+00 7.062144090000E+05 -1.350201E+01 0.000000E+00 0.000000E+00 0.000000E+00 7.118394750000E+05 -1.354938E+01 0.000000E+00 0.000000E+00 0.000000E+00 7.174645420000E+05 -1.367728E+01 0.000000E+00 0.000000E+00 0.000000E+00 7.230896080000E+05 -1.385470E+01 0.000000E+00 0.000000E+00 0.000000E+00 7.287146740000E+05 -1.390802E+01 0.000000E+00 0.000000E+00 0.000000E+00 7.343397400000E+05 -1.402569E+01 0.000000E+00 0.000000E+00 0.000000E+00 7.399648060000E+05 -1.417581E+01 0.000000E+00 0.000000E+00 0.000000E+00 7.455898720000E+05 -1.441664E+01 0.000000E+00 0.000000E+00 0.000000E+00 7.520556870000E+05 -1.564984E+01 0.000000E+00 0.000000E+00 0.000000E+00 7.595691510000E+05 -1.709406E+01 0.000000E+00 0.000000E+00 0.000000E+00 7.670826150000E+05 -1.397130E+01 0.000000E+00 0.000000E+00 0.000000E+00 7.745960790000E+05 -1.696351E+01 0.000000E+00 0.000000E+00 0.000000E+00 7.821095430000E+05 -1.143287E+01 0.000000E+00 0.000000E+00 0.000000E+00 7.896230070000E+05 -1.256861E+01 0.000000E+00 0.000000E+00 0.000000E+00 7.971364710000E+05 -1.278378E+01 0.000000E+00 0.000000E+00 0.000000E+00 8.046499350000E+05 -1.303471E+01 0.000000E+00 0.000000E+00 0.000000E+00 8.121633990000E+05 -1.319266E+01 0.000000E+00 0.000000E+00 0.000000E+00 8.196768630000E+05 -1.326769E+01 0.000000E+00 0.000000E+00 0.000000E+00 8.271903270000E+05 -1.339579E+01 0.000000E+00 0.000000E+00 0.000000E+00 8.347037910000E+05 -1.348082E+01 0.000000E+00 0.000000E+00 0.000000E+00 8.422172550000E+05 -1.346231E+01 0.000000E+00 0.000000E+00 0.000000E+00 8.497307190000E+05 -1.353800E+01 0.000000E+00 0.000000E+00 0.000000E+00 8.572441830000E+05 -1.363765E+01 0.000000E+00 0.000000E+00 0.000000E+00 8.647576470000E+05 -1.370131E+01 0.000000E+00 0.000000E+00 0.000000E+00 8.722711110000E+05 -1.376609E+01 0.000000E+00 0.000000E+00 0.000000E+00 8.797845760000E+05 -1.383782E+01 0.000000E+00 0.000000E+00 0.000000E+00 8.872980400000E+05 -1.380289E+01 0.000000E+00 0.000000E+00 0.000000E+00 8.948115040000E+05 -1.393374E+01 0.000000E+00 0.000000E+00 0.000000E+00 9.023249680000E+05 -1.405219E+01 0.000000E+00 0.000000E+00 0.000000E+00 9.098384320000E+05 -1.407736E+01 0.000000E+00 0.000000E+00 0.000000E+00 9.173518960000E+05 -1.397925E+01 0.000000E+00 0.000000E+00 0.000000E+00 9.248653600000E+05 -1.398523E+01 0.000000E+00 0.000000E+00 0.000000E+00 9.323788240000E+05 -1.418808E+01 0.000000E+00 0.000000E+00 0.000000E+00 9.398922880000E+05 -1.418902E+01 0.000000E+00 0.000000E+00 0.000000E+00 9.474057520000E+05 -1.418511E+01 0.000000E+00 0.000000E+00 0.000000E+00 9.549192160000E+05 -1.423622E+01 0.000000E+00 0.000000E+00 0.000000E+00 9.624326800000E+05 -1.438106E+01 0.000000E+00 0.000000E+00 0.000000E+00 9.699461440000E+05 -1.450662E+01 0.000000E+00 0.000000E+00 0.000000E+00 9.774596080000E+05 -1.411789E+01 0.000000E+00 0.000000E+00 0.000000E+00 9.849730720000E+05 -1.442562E+01 0.000000E+00 0.000000E+00 0.000000E+00 9.924865360000E+05 -1.444519E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.000000000000E+06 -1.440658E+01 0.000000E+00 0.000000E+00 0.000000E+00 "CHANNEL: 2" "MEASURE TYPE: A/R" "FORMAT TYPE: PHASE (DEG)" "NUMBER of POINTS: 801" "SWEEP TIME: 47.23 s" "SWEEP TYPE: LOG FREQ" "SOURCE POWER: -20 dBm" "IF BANDWIDTH: 100 Hz" "Frequency" "Data Trace Real" "Data Trace Imag" "Memory Trace Real" "Memory Trace Imag" 1.000000000000E+03 1.506158E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.009991000000E+03 1.455336E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.019981000000E+03 1.346142E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.029972000000E+03 5.477100E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.039962000000E+03 -3.740886E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.049953000000E+03 5.118205E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.059943000000E+03 1.494567E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.069934000000E+03 -4.590545E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.079925000000E+03 -1.631144E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.089915000000E+03 1.260991E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.099906000000E+03 -8.465089E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.109896000000E+03 3.419218E+00 0.000000E+00 0.000000E+00 0.000000E+00 1.119887000000E+03 1.153966E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.129877000000E+03 -1.654615E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.139868000000E+03 1.150927E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.149859000000E+03 -1.472798E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.159849000000E+03 1.158954E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.169840000000E+03 -5.025367E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.179830000000E+03 1.380423E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.189821000000E+03 -9.724258E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.199812000000E+03 7.601325E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.209802000000E+03 1.367168E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.219793000000E+03 -1.785531E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.229783000000E+03 -1.798711E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.239774000000E+03 1.417530E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.249764000000E+03 -1.184401E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.259755000000E+03 4.184910E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.269746000000E+03 6.711896E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.279736000000E+03 -3.983641E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.289727000000E+03 1.378342E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.299717000000E+03 1.997943E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.309708000000E+03 9.169637E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.319698000000E+03 1.895494E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.329689000000E+03 7.064252E+00 0.000000E+00 0.000000E+00 0.000000E+00 1.341220000000E+03 -1.749322E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.354559000000E+03 -1.563427E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.367898000000E+03 1.850871E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.381237000000E+03 1.706839E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.394577000000E+03 3.235482E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.407916000000E+03 1.676682E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.421255000000E+03 -4.862540E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.434594000000E+03 -1.699175E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.447933000000E+03 -1.760845E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.461272000000E+03 1.548262E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.474611000000E+03 1.721673E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.487950000000E+03 1.178449E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.501290000000E+03 -1.189876E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.514629000000E+03 1.312870E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.527968000000E+03 -1.623314E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.541307000000E+03 1.541684E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.554646000000E+03 5.395084E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.567985000000E+03 -1.646297E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.581324000000E+03 1.789650E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.594663000000E+03 1.404184E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.608003000000E+03 -1.553212E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.621342000000E+03 -1.468066E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.634681000000E+03 1.566698E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.648020000000E+03 -2.562889E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.661359000000E+03 6.531344E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.674698000000E+03 1.383635E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.688037000000E+03 5.863788E+00 0.000000E+00 0.000000E+00 0.000000E+00 1.701376000000E+03 1.118646E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.714716000000E+03 1.126864E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.728055000000E+03 -7.729064E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.741394000000E+03 -2.860616E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.754733000000E+03 8.981686E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.768072000000E+03 1.290309E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.783405000000E+03 -1.422068E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.801142000000E+03 8.009267E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.818879000000E+03 1.037769E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.836616000000E+03 -3.604618E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.854353000000E+03 8.150916E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.872090000000E+03 1.368795E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.889826000000E+03 6.616728E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.907563000000E+03 2.069574E+00 0.000000E+00 0.000000E+00 0.000000E+00 1.925300000000E+03 -1.267598E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.943037000000E+03 1.452400E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.960774000000E+03 8.810680E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.978511000000E+03 1.630223E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.996248000000E+03 1.706761E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.013985000000E+03 -1.777072E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.031722000000E+03 -1.395455E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.049459000000E+03 -2.684648E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.067196000000E+03 1.634287E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.084932000000E+03 7.844988E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.102669000000E+03 -2.048931E+00 0.000000E+00 0.000000E+00 0.000000E+00 2.120406000000E+03 1.017828E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.138143000000E+03 -7.093081E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.155880000000E+03 1.456119E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.173617000000E+03 1.166734E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.191354000000E+03 -1.029359E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.209091000000E+03 9.618238E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.226828000000E+03 1.281030E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.244565000000E+03 -1.655358E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.262301000000E+03 -1.525649E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.280038000000E+03 1.112416E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.297775000000E+03 1.200437E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.315512000000E+03 1.794501E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.333249000000E+03 -8.920627E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.350986000000E+03 1.479778E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.371374000000E+03 -3.237375E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.395065000000E+03 -9.188319E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.418757000000E+03 5.456569E+00 0.000000E+00 0.000000E+00 0.000000E+00 2.442448000000E+03 1.756532E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.466139000000E+03 -1.030918E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.489831000000E+03 -6.167912E+00 0.000000E+00 0.000000E+00 0.000000E+00 2.513522000000E+03 -1.113233E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.537214000000E+03 -1.077452E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.560905000000E+03 -1.105790E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.584596000000E+03 -6.220512E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.608288000000E+03 1.143505E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.631979000000E+03 1.725927E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.655670000000E+03 1.126561E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.679362000000E+03 8.719363E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.703053000000E+03 1.373178E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.726744000000E+03 -6.496491E+00 0.000000E+00 0.000000E+00 0.000000E+00 2.750436000000E+03 -1.034551E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.774127000000E+03 1.698719E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.797819000000E+03 9.677831E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.821510000000E+03 1.153191E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.845201000000E+03 1.524106E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.868893000000E+03 8.111635E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.892584000000E+03 5.800316E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.916275000000E+03 -1.263260E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.939967000000E+03 9.357074E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.963658000000E+03 -1.185547E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.987349000000E+03 -1.357741E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.011041000000E+03 -1.105311E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.034732000000E+03 -1.281081E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.058424000000E+03 1.629117E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.082115000000E+03 1.102097E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.105806000000E+03 1.581814E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.129498000000E+03 -1.020515E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.153189000000E+03 -1.173600E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.180534000000E+03 -9.609428E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.212166000000E+03 -1.362538E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.243798000000E+03 -1.297357E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.275430000000E+03 -7.022982E+00 0.000000E+00 0.000000E+00 0.000000E+00 3.307062000000E+03 -6.269557E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.338694000000E+03 1.183090E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.370326000000E+03 1.430706E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.401958000000E+03 -5.135126E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.433591000000E+03 -1.275993E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.465223000000E+03 1.007090E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.496855000000E+03 1.168978E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.528487000000E+03 1.063433E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.560119000000E+03 1.591258E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.591751000000E+03 -1.589329E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.623383000000E+03 -1.485400E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.655015000000E+03 -1.586515E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.686647000000E+03 1.022825E+00 0.000000E+00 0.000000E+00 0.000000E+00 3.718279000000E+03 -1.766304E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.749911000000E+03 1.619143E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.781543000000E+03 5.641459E+00 0.000000E+00 0.000000E+00 0.000000E+00 3.813175000000E+03 1.431094E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.844807000000E+03 1.318118E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.876439000000E+03 -7.680405E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.908071000000E+03 1.081488E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.939704000000E+03 -1.458218E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.971336000000E+03 -8.283711E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.002968000000E+03 -7.610790E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.034600000000E+03 1.640780E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.066232000000E+03 8.032503E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.097864000000E+03 1.536545E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.129496000000E+03 4.730331E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.161128000000E+03 -1.441495E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.192760000000E+03 1.234163E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.229120000000E+03 -1.730293E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.271181000000E+03 4.905172E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.313242000000E+03 1.529718E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.355302000000E+03 1.734903E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.397363000000E+03 1.076376E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.439424000000E+03 9.010429E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.481485000000E+03 1.689696E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.523546000000E+03 -1.707718E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.565607000000E+03 -6.465685E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.607667000000E+03 1.280993E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.649728000000E+03 1.642691E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.691789000000E+03 -1.751449E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.733850000000E+03 -1.569712E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.775911000000E+03 1.232101E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.817971000000E+03 1.399122E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.860032000000E+03 -1.552386E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.902093000000E+03 1.622889E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.944154000000E+03 1.202366E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.986215000000E+03 -1.734532E+02 0.000000E+00 0.000000E+00 0.000000E+00 5.028275000000E+03 -1.744114E+02 0.000000E+00 0.000000E+00 0.000000E+00 5.070336000000E+03 1.534805E+02 0.000000E+00 0.000000E+00 0.000000E+00 5.112397000000E+03 9.250823E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.154458000000E+03 9.320741E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.196519000000E+03 1.283349E+02 0.000000E+00 0.000000E+00 0.000000E+00 5.238580000000E+03 -6.291428E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.280640000000E+03 -1.016907E+02 0.000000E+00 0.000000E+00 0.000000E+00 5.322701000000E+03 -1.587687E+02 0.000000E+00 0.000000E+00 0.000000E+00 5.364762000000E+03 -1.719251E+02 0.000000E+00 0.000000E+00 0.000000E+00 5.406823000000E+03 -1.196156E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.448884000000E+03 1.501593E+02 0.000000E+00 0.000000E+00 0.000000E+00 5.490944000000E+03 1.339045E+02 0.000000E+00 0.000000E+00 0.000000E+00 5.533005000000E+03 1.319534E+02 0.000000E+00 0.000000E+00 0.000000E+00 5.575066000000E+03 1.394728E+02 0.000000E+00 0.000000E+00 0.000000E+00 5.623413000000E+03 1.468378E+02 0.000000E+00 0.000000E+00 0.000000E+00 5.679594000000E+03 -1.683260E+02 0.000000E+00 0.000000E+00 0.000000E+00 5.735775000000E+03 1.582333E+02 0.000000E+00 0.000000E+00 0.000000E+00 5.791956000000E+03 1.589470E+02 0.000000E+00 0.000000E+00 0.000000E+00 5.848137000000E+03 -1.316783E+02 0.000000E+00 0.000000E+00 0.000000E+00 5.904318000000E+03 -1.721570E+02 0.000000E+00 0.000000E+00 0.000000E+00 5.960500000000E+03 -1.549061E+02 0.000000E+00 0.000000E+00 0.000000E+00 6.016681000000E+03 1.433983E+02 0.000000E+00 0.000000E+00 0.000000E+00 6.072862000000E+03 1.787346E+02 0.000000E+00 0.000000E+00 0.000000E+00 6.129043000000E+03 1.342904E+02 0.000000E+00 0.000000E+00 0.000000E+00 6.185224000000E+03 1.602970E+02 0.000000E+00 0.000000E+00 0.000000E+00 6.241405000000E+03 -1.732063E+02 0.000000E+00 0.000000E+00 0.000000E+00 6.297586000000E+03 1.426882E+02 0.000000E+00 0.000000E+00 0.000000E+00 6.353767000000E+03 -1.639266E+02 0.000000E+00 0.000000E+00 0.000000E+00 6.409948000000E+03 -1.251998E+02 0.000000E+00 0.000000E+00 0.000000E+00 6.466129000000E+03 -1.781964E+02 0.000000E+00 0.000000E+00 0.000000E+00 6.522310000000E+03 1.674263E+02 0.000000E+00 0.000000E+00 0.000000E+00 6.578492000000E+03 -1.453556E+02 0.000000E+00 0.000000E+00 0.000000E+00 6.634673000000E+03 9.746233E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.690854000000E+03 -1.310757E+02 0.000000E+00 0.000000E+00 0.000000E+00 6.747035000000E+03 1.425604E+02 0.000000E+00 0.000000E+00 0.000000E+00 6.803216000000E+03 -1.650328E+02 0.000000E+00 0.000000E+00 0.000000E+00 6.859397000000E+03 -1.551464E+02 0.000000E+00 0.000000E+00 0.000000E+00 6.915578000000E+03 -1.495172E+02 0.000000E+00 0.000000E+00 0.000000E+00 6.971759000000E+03 -1.642524E+02 0.000000E+00 0.000000E+00 0.000000E+00 7.027940000000E+03 -1.682739E+02 0.000000E+00 0.000000E+00 0.000000E+00 7.084121000000E+03 -1.274449E+02 0.000000E+00 0.000000E+00 0.000000E+00 7.140302000000E+03 -1.646213E+02 0.000000E+00 0.000000E+00 0.000000E+00 7.196484000000E+03 -1.646961E+02 0.000000E+00 0.000000E+00 0.000000E+00 7.252665000000E+03 -1.643408E+02 0.000000E+00 0.000000E+00 0.000000E+00 7.308846000000E+03 -1.422077E+02 0.000000E+00 0.000000E+00 0.000000E+00 7.365027000000E+03 1.631306E+02 0.000000E+00 0.000000E+00 0.000000E+00 7.421208000000E+03 -1.474851E+02 0.000000E+00 0.000000E+00 0.000000E+00 7.477389000000E+03 1.705795E+02 0.000000E+00 0.000000E+00 0.000000E+00 7.542234000000E+03 -1.272061E+02 0.000000E+00 0.000000E+00 0.000000E+00 7.617245000000E+03 -1.005737E+02 0.000000E+00 0.000000E+00 0.000000E+00 7.692257000000E+03 1.158349E+02 0.000000E+00 0.000000E+00 0.000000E+00 7.767268000000E+03 -1.583036E+02 0.000000E+00 0.000000E+00 0.000000E+00 7.842280000000E+03 -1.025808E+02 0.000000E+00 0.000000E+00 0.000000E+00 7.917291000000E+03 -1.237907E+01 0.000000E+00 0.000000E+00 0.000000E+00 7.992303000000E+03 -1.150497E+02 0.000000E+00 0.000000E+00 0.000000E+00 8.067314000000E+03 -1.542826E+02 0.000000E+00 0.000000E+00 0.000000E+00 8.142326000000E+03 -8.772384E+01 0.000000E+00 0.000000E+00 0.000000E+00 8.217337000000E+03 -1.251476E+02 0.000000E+00 0.000000E+00 0.000000E+00 8.292349000000E+03 -1.746438E+02 0.000000E+00 0.000000E+00 0.000000E+00 8.367360000000E+03 -6.839736E+01 0.000000E+00 0.000000E+00 0.000000E+00 8.442372000000E+03 -1.369767E+02 0.000000E+00 0.000000E+00 0.000000E+00 8.517383000000E+03 -1.228630E+02 0.000000E+00 0.000000E+00 0.000000E+00 8.592395000000E+03 1.738606E+02 0.000000E+00 0.000000E+00 0.000000E+00 8.667406000000E+03 1.415715E+02 0.000000E+00 0.000000E+00 0.000000E+00 8.742418000000E+03 -1.394460E+02 0.000000E+00 0.000000E+00 0.000000E+00 8.817429000000E+03 -1.618518E+02 0.000000E+00 0.000000E+00 0.000000E+00 8.892440000000E+03 1.721183E+02 0.000000E+00 0.000000E+00 0.000000E+00 8.967452000000E+03 -1.194476E+02 0.000000E+00 0.000000E+00 0.000000E+00 9.042463000000E+03 -1.447533E+02 0.000000E+00 0.000000E+00 0.000000E+00 9.117475000000E+03 -1.276996E+02 0.000000E+00 0.000000E+00 0.000000E+00 9.192486000000E+03 -1.213280E+02 0.000000E+00 0.000000E+00 0.000000E+00 9.267498000000E+03 -1.610165E+02 0.000000E+00 0.000000E+00 0.000000E+00 9.342509000000E+03 -1.586790E+02 0.000000E+00 0.000000E+00 0.000000E+00 9.417521000000E+03 1.413829E+02 0.000000E+00 0.000000E+00 0.000000E+00 9.492532000000E+03 -8.371415E+01 0.000000E+00 0.000000E+00 0.000000E+00 9.567544000000E+03 -1.073500E+02 0.000000E+00 0.000000E+00 0.000000E+00 9.642555000000E+03 -8.695525E+01 0.000000E+00 0.000000E+00 0.000000E+00 9.717567000000E+03 -7.001472E+01 0.000000E+00 0.000000E+00 0.000000E+00 9.792578000000E+03 1.563977E+02 0.000000E+00 0.000000E+00 0.000000E+00 9.867590000000E+03 -1.589177E+02 0.000000E+00 0.000000E+00 0.000000E+00 9.942601000000E+03 1.179401E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.002882400000E+04 -1.517345E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.012856600000E+04 -6.091747E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.022830800000E+04 -1.219292E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.032805000000E+04 -1.593138E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.042779200000E+04 1.710466E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.052753400000E+04 -1.796053E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.062727500000E+04 -1.600780E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.072701700000E+04 1.358974E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.082675900000E+04 -1.580844E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.092650100000E+04 -1.592120E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.102624300000E+04 -9.116237E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.112598500000E+04 1.669836E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.122572700000E+04 3.557825E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.132546900000E+04 1.500724E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.142521100000E+04 -1.441869E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.152495300000E+04 6.709332E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.162469500000E+04 -1.497647E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.172443600000E+04 1.554779E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.182417800000E+04 5.835511E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.192392000000E+04 -4.939175E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.202366200000E+04 -1.252666E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.212340400000E+04 -1.417982E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.222314600000E+04 -1.308929E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.232288800000E+04 1.179918E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.242263000000E+04 1.784036E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.252237200000E+04 -1.273626E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.262211400000E+04 1.744457E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.272185500000E+04 -4.994414E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.282159700000E+04 -1.779817E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.292133900000E+04 -1.376906E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.302108100000E+04 7.053967E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.312082300000E+04 -1.420531E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.322056500000E+04 -5.544885E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.333521400000E+04 -1.341253E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.346844000000E+04 1.584434E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.360166700000E+04 8.213655E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.373489300000E+04 1.571072E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.386812000000E+04 1.463452E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.400134600000E+04 -1.319966E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.413457200000E+04 1.597761E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.426779900000E+04 -1.323422E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.440102500000E+04 1.157531E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.453425200000E+04 3.546677E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.466747800000E+04 9.264059E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.480070400000E+04 -3.611030E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.493393100000E+04 1.730537E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.506715700000E+04 1.372610E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.520038400000E+04 1.175339E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.533361000000E+04 1.079488E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.546683600000E+04 1.562636E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.560006300000E+04 1.369401E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.573328900000E+04 8.786243E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.586651500000E+04 6.209478E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.599974200000E+04 1.662583E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.613296800000E+04 7.649685E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.626619500000E+04 3.700311E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.639942100000E+04 9.548180E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.653264700000E+04 1.093035E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.666587400000E+04 6.142749E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.679910000000E+04 -1.605905E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.693232700000E+04 7.728189E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.706555300000E+04 7.843712E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.719877900000E+04 9.483220E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.733200600000E+04 2.376877E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.746523200000E+04 1.598008E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.759845900000E+04 7.261439E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.773168500000E+04 9.674293E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.788545500000E+04 1.117099E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.806333500000E+04 7.016712E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.824121500000E+04 8.682403E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.841909600000E+04 6.689130E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.859697600000E+04 5.840776E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.877485600000E+04 7.682658E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.895273600000E+04 7.556263E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.913061700000E+04 1.047861E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.930849700000E+04 5.391118E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.948637700000E+04 6.239273E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.966425700000E+04 8.667290E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.984213700000E+04 5.325071E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.002001800000E+04 9.999642E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.019789800000E+04 8.948052E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.037577800000E+04 9.626621E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.055365800000E+04 8.449308E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.073153900000E+04 8.042366E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.090941900000E+04 8.310658E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.108729900000E+04 6.913563E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.126517900000E+04 9.099641E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.144305900000E+04 9.631158E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.162094000000E+04 9.601572E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.179882000000E+04 1.052262E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.197670000000E+04 9.542452E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.215458000000E+04 1.089295E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.233246000000E+04 1.092437E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.251034100000E+04 1.043359E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.268822100000E+04 1.132372E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.286610100000E+04 1.302913E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.304398100000E+04 1.167996E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.322186200000E+04 1.269573E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.339974200000E+04 1.299448E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.357762200000E+04 1.254878E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.378208900000E+04 1.348681E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.401861400000E+04 1.400415E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.425514000000E+04 1.420264E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.449166500000E+04 1.438577E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.472819000000E+04 1.495455E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.496471600000E+04 1.405738E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.520124100000E+04 1.518187E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.543776600000E+04 1.549356E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.567429200000E+04 1.563636E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.591081700000E+04 1.513544E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.614734200000E+04 1.575641E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.638386700000E+04 1.590896E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.662039300000E+04 1.648723E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.685691800000E+04 1.667737E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.709344300000E+04 1.623350E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.732996900000E+04 1.607532E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.756649400000E+04 1.610060E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.780301900000E+04 1.675163E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.803954500000E+04 1.652443E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.827607000000E+04 1.663841E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.851259500000E+04 1.670648E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.874912100000E+04 1.660396E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.898564600000E+04 1.653690E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.922217100000E+04 1.590633E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.945869700000E+04 1.667416E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.969522200000E+04 1.691400E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.993174700000E+04 1.706797E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.016827200000E+04 1.693117E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.040479800000E+04 1.656182E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.064132300000E+04 1.691023E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.087784800000E+04 1.704200E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.111437400000E+04 1.668991E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.135089900000E+04 1.737875E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.162277700000E+04 1.678137E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.193870700000E+04 1.701046E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.225463600000E+04 1.656069E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.257056600000E+04 1.744056E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.288649500000E+04 1.714136E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.320242500000E+04 1.640372E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.351835400000E+04 1.732397E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.383428400000E+04 1.713941E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.415021300000E+04 1.694026E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.446614300000E+04 1.712670E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.478207200000E+04 1.690782E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.509800200000E+04 1.681673E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.541393100000E+04 1.661026E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.572986100000E+04 1.640443E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.604579000000E+04 1.648340E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.636172000000E+04 1.701670E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.667764900000E+04 1.670024E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.699357900000E+04 1.657263E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.730950800000E+04 1.670351E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.762543800000E+04 1.699147E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.794136700000E+04 1.628916E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.825729700000E+04 1.686406E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.857322600000E+04 1.697838E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.888915600000E+04 1.694093E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.920508500000E+04 1.692281E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.952101500000E+04 1.670193E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.983694400000E+04 1.670099E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.015287400000E+04 1.626732E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.046880300000E+04 1.634427E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.078473300000E+04 1.647774E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.110066200000E+04 1.670007E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.141659200000E+04 1.646381E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.173252100000E+04 1.668979E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.204845100000E+04 1.645809E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.241309800000E+04 1.659649E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.283491800000E+04 1.640390E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.325673900000E+04 1.655083E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.367855900000E+04 1.654264E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.410038000000E+04 1.646481E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.452220000000E+04 1.630015E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.494402100000E+04 1.648622E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.536584100000E+04 1.658694E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.578766200000E+04 1.654371E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.620948200000E+04 1.632749E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.663130300000E+04 1.677105E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.705312300000E+04 1.651247E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.747494400000E+04 1.664493E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.789676400000E+04 1.627256E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.831858500000E+04 1.615935E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.874040500000E+04 1.626341E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.916222600000E+04 1.608116E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.958404600000E+04 1.644091E+02 0.000000E+00 0.000000E+00 0.000000E+00 5.000586600000E+04 1.634909E+02 0.000000E+00 0.000000E+00 0.000000E+00 5.042768700000E+04 1.639329E+02 0.000000E+00 0.000000E+00 0.000000E+00 5.084950700000E+04 1.619753E+02 0.000000E+00 0.000000E+00 0.000000E+00 5.127132800000E+04 1.644609E+02 0.000000E+00 0.000000E+00 0.000000E+00 5.169314800000E+04 1.649687E+02 0.000000E+00 0.000000E+00 0.000000E+00 5.211496900000E+04 1.631098E+02 0.000000E+00 0.000000E+00 0.000000E+00 5.253678900000E+04 1.641838E+02 0.000000E+00 0.000000E+00 0.000000E+00 5.295861000000E+04 1.619939E+02 0.000000E+00 0.000000E+00 0.000000E+00 5.338043000000E+04 1.625047E+02 0.000000E+00 0.000000E+00 0.000000E+00 5.380225100000E+04 1.633163E+02 0.000000E+00 0.000000E+00 0.000000E+00 5.422407100000E+04 1.646768E+02 0.000000E+00 0.000000E+00 0.000000E+00 5.464589200000E+04 1.659996E+02 0.000000E+00 0.000000E+00 0.000000E+00 5.506771200000E+04 1.638608E+02 0.000000E+00 0.000000E+00 0.000000E+00 5.548953300000E+04 1.614961E+02 0.000000E+00 0.000000E+00 0.000000E+00 5.591135300000E+04 1.619210E+02 0.000000E+00 0.000000E+00 0.000000E+00 5.639622100000E+04 1.633237E+02 0.000000E+00 0.000000E+00 0.000000E+00 5.695711100000E+04 1.657865E+02 0.000000E+00 0.000000E+00 0.000000E+00 5.751800100000E+04 1.638142E+02 0.000000E+00 0.000000E+00 0.000000E+00 5.807889100000E+04 1.644374E+02 0.000000E+00 0.000000E+00 0.000000E+00 5.863978100000E+04 1.645004E+02 0.000000E+00 0.000000E+00 0.000000E+00 5.920067100000E+04 1.657677E+02 0.000000E+00 0.000000E+00 0.000000E+00 5.976156000000E+04 1.649677E+02 0.000000E+00 0.000000E+00 0.000000E+00 6.032245000000E+04 1.659089E+02 0.000000E+00 0.000000E+00 0.000000E+00 6.088334000000E+04 1.652737E+02 0.000000E+00 0.000000E+00 0.000000E+00 6.144423000000E+04 1.660514E+02 0.000000E+00 0.000000E+00 0.000000E+00 6.200512000000E+04 1.665228E+02 0.000000E+00 0.000000E+00 0.000000E+00 6.256601000000E+04 1.669007E+02 0.000000E+00 0.000000E+00 0.000000E+00 6.312690000000E+04 1.664034E+02 0.000000E+00 0.000000E+00 0.000000E+00 6.368779000000E+04 1.677055E+02 0.000000E+00 0.000000E+00 0.000000E+00 6.424868000000E+04 1.662230E+02 0.000000E+00 0.000000E+00 0.000000E+00 6.480957000000E+04 1.668873E+02 0.000000E+00 0.000000E+00 0.000000E+00 6.537046000000E+04 1.667743E+02 0.000000E+00 0.000000E+00 0.000000E+00 6.593134900000E+04 1.669914E+02 0.000000E+00 0.000000E+00 0.000000E+00 6.649223900000E+04 1.683689E+02 0.000000E+00 0.000000E+00 0.000000E+00 6.705312900000E+04 1.662418E+02 0.000000E+00 0.000000E+00 0.000000E+00 6.761401900000E+04 1.679178E+02 0.000000E+00 0.000000E+00 0.000000E+00 6.817490900000E+04 1.681158E+02 0.000000E+00 0.000000E+00 0.000000E+00 6.873579900000E+04 1.679441E+02 0.000000E+00 0.000000E+00 0.000000E+00 6.929668900000E+04 1.687522E+02 0.000000E+00 0.000000E+00 0.000000E+00 6.985757900000E+04 1.697096E+02 0.000000E+00 0.000000E+00 0.000000E+00 7.041846900000E+04 1.687958E+02 0.000000E+00 0.000000E+00 0.000000E+00 7.097935900000E+04 1.686034E+02 0.000000E+00 0.000000E+00 0.000000E+00 7.154024800000E+04 1.706178E+02 0.000000E+00 0.000000E+00 0.000000E+00 7.210113800000E+04 1.706145E+02 0.000000E+00 0.000000E+00 0.000000E+00 7.266202800000E+04 1.711184E+02 0.000000E+00 0.000000E+00 0.000000E+00 7.322291800000E+04 1.703899E+02 0.000000E+00 0.000000E+00 0.000000E+00 7.378380800000E+04 1.712795E+02 0.000000E+00 0.000000E+00 0.000000E+00 7.434469800000E+04 1.707353E+02 0.000000E+00 0.000000E+00 0.000000E+00 7.498942100000E+04 1.713195E+02 0.000000E+00 0.000000E+00 0.000000E+00 7.573860800000E+04 1.713134E+02 0.000000E+00 0.000000E+00 0.000000E+00 7.648779500000E+04 1.716118E+02 0.000000E+00 0.000000E+00 0.000000E+00 7.723698200000E+04 1.725193E+02 0.000000E+00 0.000000E+00 0.000000E+00 7.798616900000E+04 1.737549E+02 0.000000E+00 0.000000E+00 0.000000E+00 7.873535600000E+04 1.730266E+02 0.000000E+00 0.000000E+00 0.000000E+00 7.948454300000E+04 1.737187E+02 0.000000E+00 0.000000E+00 0.000000E+00 8.023373000000E+04 1.740752E+02 0.000000E+00 0.000000E+00 0.000000E+00 8.098291700000E+04 1.742514E+02 0.000000E+00 0.000000E+00 0.000000E+00 8.173210400000E+04 1.748893E+02 0.000000E+00 0.000000E+00 0.000000E+00 8.248129100000E+04 1.761215E+02 0.000000E+00 0.000000E+00 0.000000E+00 8.323047800000E+04 1.761226E+02 0.000000E+00 0.000000E+00 0.000000E+00 8.397966500000E+04 1.763622E+02 0.000000E+00 0.000000E+00 0.000000E+00 8.472885200000E+04 1.771667E+02 0.000000E+00 0.000000E+00 0.000000E+00 8.547803900000E+04 1.776598E+02 0.000000E+00 0.000000E+00 0.000000E+00 8.622722600000E+04 1.780039E+02 0.000000E+00 0.000000E+00 0.000000E+00 8.697641300000E+04 1.778487E+02 0.000000E+00 0.000000E+00 0.000000E+00 8.772559900000E+04 1.791601E+02 0.000000E+00 0.000000E+00 0.000000E+00 8.847478600000E+04 1.796463E+02 0.000000E+00 0.000000E+00 0.000000E+00 8.922397300000E+04 1.798890E+02 0.000000E+00 0.000000E+00 0.000000E+00 8.997316000000E+04 -1.794776E+02 0.000000E+00 0.000000E+00 0.000000E+00 9.072234700000E+04 -1.789502E+02 0.000000E+00 0.000000E+00 0.000000E+00 9.147153400000E+04 -1.793179E+02 0.000000E+00 0.000000E+00 0.000000E+00 9.222072100000E+04 -1.781792E+02 0.000000E+00 0.000000E+00 0.000000E+00 9.296990800000E+04 -1.779519E+02 0.000000E+00 0.000000E+00 0.000000E+00 9.371909500000E+04 -1.774687E+02 0.000000E+00 0.000000E+00 0.000000E+00 9.446828200000E+04 -1.779311E+02 0.000000E+00 0.000000E+00 0.000000E+00 9.521746900000E+04 -1.769786E+02 0.000000E+00 0.000000E+00 0.000000E+00 9.596665600000E+04 -1.778865E+02 0.000000E+00 0.000000E+00 0.000000E+00 9.671584300000E+04 -1.759906E+02 0.000000E+00 0.000000E+00 0.000000E+00 9.746503000000E+04 -1.760412E+02 0.000000E+00 0.000000E+00 0.000000E+00 9.821421700000E+04 -1.755487E+02 0.000000E+00 0.000000E+00 0.000000E+00 9.896340400000E+04 -1.757806E+02 0.000000E+00 0.000000E+00 0.000000E+00 9.971259100000E+04 -1.767082E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.005773060000E+05 -1.793907E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.015776000000E+05 -1.763819E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.025778940000E+05 -1.761339E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.035781880000E+05 -1.742339E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.045784820000E+05 -1.723090E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.055787760000E+05 -1.712252E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.065790700000E+05 -1.693996E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.075793640000E+05 -1.699535E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.085796580000E+05 -1.696800E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.095799510000E+05 -1.693177E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.105802450000E+05 -1.689455E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.115805390000E+05 -1.681491E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.125808330000E+05 -1.675722E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.135811270000E+05 -1.653497E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.145814210000E+05 -1.656976E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.155817150000E+05 -1.665547E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.165820090000E+05 -1.654601E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.175823030000E+05 -1.643479E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.185825970000E+05 -1.641207E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.195828910000E+05 -1.636230E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.205831850000E+05 -1.633646E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.215834790000E+05 -1.626759E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.225837730000E+05 -1.623751E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.235840670000E+05 -1.615886E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.245843610000E+05 -1.607829E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.255846540000E+05 -1.603510E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.265849480000E+05 -1.592865E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.275852420000E+05 -1.591624E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.285855360000E+05 -1.580153E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.295858300000E+05 -1.564424E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.305861240000E+05 -1.531739E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.315864180000E+05 -1.536555E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.325867120000E+05 -1.554080E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.337365140000E+05 -1.559096E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.350665940000E+05 -1.558815E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.363966730000E+05 -1.550980E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.377267530000E+05 -1.542259E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.390568320000E+05 -1.540506E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.403869120000E+05 -1.531944E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.417169920000E+05 -1.533371E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.430470710000E+05 -1.528065E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.443771510000E+05 -1.536979E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.457072300000E+05 -1.548954E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.470373100000E+05 -1.572787E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.483673900000E+05 -1.598414E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.496974690000E+05 -1.655273E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.510275490000E+05 -1.748048E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.523576280000E+05 1.743168E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.536877080000E+05 -1.787591E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.550177880000E+05 -1.597540E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.563478670000E+05 -1.522697E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.576779470000E+05 -1.494224E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.590080260000E+05 -1.484570E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.603381060000E+05 -1.486362E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.616681850000E+05 -1.482204E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.629982650000E+05 -1.490803E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.643283450000E+05 -1.493445E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.656584240000E+05 -1.483582E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.669885040000E+05 -1.506995E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.683185830000E+05 -1.490603E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.696486630000E+05 -1.479134E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.709787430000E+05 -1.508058E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.723088220000E+05 -1.527962E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.736389020000E+05 -1.484951E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.749689810000E+05 -1.383399E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.762990610000E+05 -1.311274E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.778279410000E+05 -1.305384E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.796045430000E+05 -1.351625E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.813811460000E+05 -1.361574E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.831577480000E+05 -1.349696E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.849343500000E+05 -1.371532E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.867109520000E+05 -1.323838E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.884875550000E+05 -1.292593E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.902641570000E+05 -1.268509E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.920407590000E+05 -1.280539E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.938173610000E+05 -1.290925E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.955939640000E+05 -1.339060E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.973705660000E+05 -1.372866E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.991471680000E+05 -1.376455E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.009237710000E+05 -1.379637E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.027003730000E+05 -1.306746E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.044769750000E+05 -1.359483E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.062535770000E+05 -1.391871E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.080301800000E+05 -1.390119E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.098067820000E+05 -1.348609E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.115833840000E+05 -1.274044E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.133599860000E+05 -1.274500E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.151365890000E+05 -1.273084E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.169131910000E+05 -1.240983E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.186897930000E+05 -1.252618E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.204663960000E+05 -1.210594E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.222429980000E+05 -1.193948E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.240196000000E+05 -1.207634E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.257962020000E+05 -1.196199E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.275728050000E+05 -1.181505E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.293494070000E+05 -1.178470E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.311260090000E+05 -1.187594E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.329026110000E+05 -1.149168E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.346792140000E+05 -1.140249E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.364558160000E+05 -1.107474E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.385063800000E+05 -1.070766E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.408784510000E+05 -1.074746E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.432505210000E+05 -1.198832E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.456225920000E+05 -1.251568E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.479946630000E+05 -1.185652E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.503667330000E+05 -1.257321E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.527388040000E+05 -1.219104E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.551108750000E+05 -1.183994E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.574829460000E+05 -1.145825E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.598550160000E+05 -1.105934E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.622270870000E+05 -1.105534E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.645991580000E+05 -1.119182E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.669712280000E+05 -1.147195E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.693432990000E+05 -1.190786E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.717153700000E+05 -1.207514E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.740874400000E+05 -1.220041E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.764595110000E+05 -1.231078E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.788315820000E+05 -1.244566E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.812036520000E+05 -1.248590E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.835757230000E+05 -1.237006E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.859477940000E+05 -1.214747E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.883198640000E+05 -1.231084E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.906919350000E+05 -1.208147E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.930640060000E+05 -1.242301E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.954360770000E+05 -1.283986E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.978081470000E+05 -1.302212E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.001802180000E+05 -1.308148E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.025522890000E+05 -1.309168E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.049243590000E+05 -1.298130E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.072964300000E+05 -1.286811E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.096685010000E+05 -1.289291E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.120405710000E+05 -1.305775E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.144126420000E+05 -1.307155E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.171392540000E+05 -1.299171E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.202933700000E+05 -1.285976E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.234474860000E+05 -1.271361E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.266016010000E+05 -1.263821E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.297557170000E+05 -1.260170E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.329098330000E+05 -1.255807E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.360639490000E+05 -1.253134E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.392180640000E+05 -1.262416E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.423721800000E+05 -1.258766E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.455262960000E+05 -1.255362E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.486804120000E+05 -1.257561E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.518345270000E+05 -1.249841E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.549886430000E+05 -1.234309E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.581427590000E+05 -1.238810E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.612968750000E+05 -1.232626E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.644509900000E+05 -1.238470E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.676051060000E+05 -1.249590E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.707592220000E+05 -1.235384E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.739133380000E+05 -1.232335E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.770674530000E+05 -1.242039E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.802215690000E+05 -1.245487E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.833756850000E+05 -1.249532E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.865298010000E+05 -1.256805E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.896839160000E+05 -1.227392E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.928380320000E+05 -1.224271E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.959921480000E+05 -1.231147E+02 0.000000E+00 0.000000E+00 0.000000E+00 3.991462640000E+05 -1.227382E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.023003790000E+05 -1.236690E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.054544950000E+05 -1.234731E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.086086110000E+05 -1.232212E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.117627270000E+05 -1.243651E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.149168420000E+05 -1.239054E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.180709580000E+05 -1.240482E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.216965030000E+05 -1.235477E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.259094910000E+05 -1.235906E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.301224790000E+05 -1.233996E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.343354670000E+05 -1.233149E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.385484550000E+05 -1.238843E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.427614430000E+05 -1.229008E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.469744300000E+05 -1.238880E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.511874180000E+05 -1.230964E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.554004060000E+05 -1.237488E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.596133940000E+05 -1.236506E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.638263820000E+05 -1.241095E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.680393700000E+05 -1.239323E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.722523580000E+05 -1.236268E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.764653460000E+05 -1.238665E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.806783340000E+05 -1.240677E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.848913220000E+05 -1.240432E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.891043100000E+05 -1.244010E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.933172970000E+05 -1.236416E+02 0.000000E+00 0.000000E+00 0.000000E+00 4.975302850000E+05 -1.245489E+02 0.000000E+00 0.000000E+00 0.000000E+00 5.017432730000E+05 -1.250787E+02 0.000000E+00 0.000000E+00 0.000000E+00 5.059562610000E+05 -1.251916E+02 0.000000E+00 0.000000E+00 0.000000E+00 5.101692490000E+05 -1.248854E+02 0.000000E+00 0.000000E+00 0.000000E+00 5.143822370000E+05 -1.250454E+02 0.000000E+00 0.000000E+00 0.000000E+00 5.185952250000E+05 -1.253302E+02 0.000000E+00 0.000000E+00 0.000000E+00 5.228082130000E+05 -1.250254E+02 0.000000E+00 0.000000E+00 0.000000E+00 5.270212010000E+05 -1.256058E+02 0.000000E+00 0.000000E+00 0.000000E+00 5.312341890000E+05 -1.252122E+02 0.000000E+00 0.000000E+00 0.000000E+00 5.354471770000E+05 -1.263550E+02 0.000000E+00 0.000000E+00 0.000000E+00 5.396601640000E+05 -1.257383E+02 0.000000E+00 0.000000E+00 0.000000E+00 5.438731520000E+05 -1.263268E+02 0.000000E+00 0.000000E+00 0.000000E+00 5.480861400000E+05 -1.255055E+02 0.000000E+00 0.000000E+00 0.000000E+00 5.522991280000E+05 -1.262161E+02 0.000000E+00 0.000000E+00 0.000000E+00 5.565121160000E+05 -1.265952E+02 0.000000E+00 0.000000E+00 0.000000E+00 5.607251040000E+05 -1.270586E+02 0.000000E+00 0.000000E+00 0.000000E+00 5.655877570000E+05 -1.265409E+02 0.000000E+00 0.000000E+00 0.000000E+00 5.712128230000E+05 -1.268277E+02 0.000000E+00 0.000000E+00 0.000000E+00 5.768378890000E+05 -1.274876E+02 0.000000E+00 0.000000E+00 0.000000E+00 5.824629550000E+05 -1.268052E+02 0.000000E+00 0.000000E+00 0.000000E+00 5.880880210000E+05 -1.277970E+02 0.000000E+00 0.000000E+00 0.000000E+00 5.937130870000E+05 -1.267434E+02 0.000000E+00 0.000000E+00 0.000000E+00 5.993381540000E+05 -1.270730E+02 0.000000E+00 0.000000E+00 0.000000E+00 6.049632200000E+05 -1.275569E+02 0.000000E+00 0.000000E+00 0.000000E+00 6.105882860000E+05 -1.284341E+02 0.000000E+00 0.000000E+00 0.000000E+00 6.162133520000E+05 -1.280067E+02 0.000000E+00 0.000000E+00 0.000000E+00 6.218384180000E+05 -1.279646E+02 0.000000E+00 0.000000E+00 0.000000E+00 6.274634840000E+05 -1.289252E+02 0.000000E+00 0.000000E+00 0.000000E+00 6.330885500000E+05 -1.281557E+02 0.000000E+00 0.000000E+00 0.000000E+00 6.387136160000E+05 -1.287091E+02 0.000000E+00 0.000000E+00 0.000000E+00 6.443386820000E+05 -1.289909E+02 0.000000E+00 0.000000E+00 0.000000E+00 6.499637480000E+05 -1.283744E+02 0.000000E+00 0.000000E+00 0.000000E+00 6.555888150000E+05 -1.297171E+02 0.000000E+00 0.000000E+00 0.000000E+00 6.612138810000E+05 -1.296275E+02 0.000000E+00 0.000000E+00 0.000000E+00 6.668389470000E+05 -1.297409E+02 0.000000E+00 0.000000E+00 0.000000E+00 6.724640130000E+05 -1.303396E+02 0.000000E+00 0.000000E+00 0.000000E+00 6.780890790000E+05 -1.303910E+02 0.000000E+00 0.000000E+00 0.000000E+00 6.837141450000E+05 -1.301237E+02 0.000000E+00 0.000000E+00 0.000000E+00 6.893392110000E+05 -1.305725E+02 0.000000E+00 0.000000E+00 0.000000E+00 6.949642770000E+05 -1.307199E+02 0.000000E+00 0.000000E+00 0.000000E+00 7.005893430000E+05 -1.306109E+02 0.000000E+00 0.000000E+00 0.000000E+00 7.062144090000E+05 -1.305951E+02 0.000000E+00 0.000000E+00 0.000000E+00 7.118394750000E+05 -1.309243E+02 0.000000E+00 0.000000E+00 0.000000E+00 7.174645420000E+05 -1.318872E+02 0.000000E+00 0.000000E+00 0.000000E+00 7.230896080000E+05 -1.317216E+02 0.000000E+00 0.000000E+00 0.000000E+00 7.287146740000E+05 -1.319218E+02 0.000000E+00 0.000000E+00 0.000000E+00 7.343397400000E+05 -1.321740E+02 0.000000E+00 0.000000E+00 0.000000E+00 7.399648060000E+05 -1.329254E+02 0.000000E+00 0.000000E+00 0.000000E+00 7.455898720000E+05 -1.327736E+02 0.000000E+00 0.000000E+00 0.000000E+00 7.520556870000E+05 -1.316694E+02 0.000000E+00 0.000000E+00 0.000000E+00 7.595691510000E+05 -1.280367E+02 0.000000E+00 0.000000E+00 0.000000E+00 7.670826150000E+05 -1.265706E+02 0.000000E+00 0.000000E+00 0.000000E+00 7.745960790000E+05 -1.292937E+02 0.000000E+00 0.000000E+00 0.000000E+00 7.821095430000E+05 -1.341050E+02 0.000000E+00 0.000000E+00 0.000000E+00 7.896230070000E+05 -1.349610E+02 0.000000E+00 0.000000E+00 0.000000E+00 7.971364710000E+05 -1.348880E+02 0.000000E+00 0.000000E+00 0.000000E+00 8.046499350000E+05 -1.358292E+02 0.000000E+00 0.000000E+00 0.000000E+00 8.121633990000E+05 -1.362611E+02 0.000000E+00 0.000000E+00 0.000000E+00 8.196768630000E+05 -1.367545E+02 0.000000E+00 0.000000E+00 0.000000E+00 8.271903270000E+05 -1.372875E+02 0.000000E+00 0.000000E+00 0.000000E+00 8.347037910000E+05 -1.381131E+02 0.000000E+00 0.000000E+00 0.000000E+00 8.422172550000E+05 -1.380357E+02 0.000000E+00 0.000000E+00 0.000000E+00 8.497307190000E+05 -1.391381E+02 0.000000E+00 0.000000E+00 0.000000E+00 8.572441830000E+05 -1.395195E+02 0.000000E+00 0.000000E+00 0.000000E+00 8.647576470000E+05 -1.396168E+02 0.000000E+00 0.000000E+00 0.000000E+00 8.722711110000E+05 -1.402331E+02 0.000000E+00 0.000000E+00 0.000000E+00 8.797845760000E+05 -1.406534E+02 0.000000E+00 0.000000E+00 0.000000E+00 8.872980400000E+05 -1.413727E+02 0.000000E+00 0.000000E+00 0.000000E+00 8.948115040000E+05 -1.421860E+02 0.000000E+00 0.000000E+00 0.000000E+00 9.023249680000E+05 -1.422106E+02 0.000000E+00 0.000000E+00 0.000000E+00 9.098384320000E+05 -1.428954E+02 0.000000E+00 0.000000E+00 0.000000E+00 9.173518960000E+05 -1.432345E+02 0.000000E+00 0.000000E+00 0.000000E+00 9.248653600000E+05 -1.439637E+02 0.000000E+00 0.000000E+00 0.000000E+00 9.323788240000E+05 -1.446781E+02 0.000000E+00 0.000000E+00 0.000000E+00 9.398922880000E+05 -1.450963E+02 0.000000E+00 0.000000E+00 0.000000E+00 9.474057520000E+05 -1.459288E+02 0.000000E+00 0.000000E+00 0.000000E+00 9.549192160000E+05 -1.464973E+02 0.000000E+00 0.000000E+00 0.000000E+00 9.624326800000E+05 -1.466476E+02 0.000000E+00 0.000000E+00 0.000000E+00 9.699461440000E+05 -1.478688E+02 0.000000E+00 0.000000E+00 0.000000E+00 9.774596080000E+05 -1.476248E+02 0.000000E+00 0.000000E+00 0.000000E+00 9.849730720000E+05 -1.489600E+02 0.000000E+00 0.000000E+00 0.000000E+00 9.924865360000E+05 -1.490872E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.000000000000E+06 -1.497773E+02 0.000000E+00 0.000000E+00 0.000000E+00