================================================================================ Dolphin diagnostic tool -- dis_diag version 5.7.0 (Tue Nov 20 09:15:53 PST 2018) ================================================================================ dis_diag compiled in 64 bit mode Driver : Dolphin IRM (GX) 5.7.0 Aug 8th 2018 (rev 8a53628) Date : Mon Oct 14 12:43:37 PDT 2019 System : Linux h1iscey 3.0.8 #2 SMP Fri Mar 4 14:45:06 CST 2016 x86_64 Intel(R) Xeon(R) CPU E5-1660 v4 @ 3.20GHz GenuineIntel GNU/Linux Number of configured local adapters found: 1 Adapter 0 > Type : IXH611 Mode : NTB NodeId : 76 Serial number : IXH611-CE-002374 IXH chip family : IDT_LOGAN IXH chip vendorId : 0x111d IXH chip device : 0x8091 IXH chip revision : 0x2 (ZC) EEPROM version : 97 EEPROM vendor info : 0x0000 EEPROM development ver : 1 EEPROM swmode[3:0] : 0010 EEPROM images : 03 Card revision : CE Topology type : Switch Topology Autodetect : No Number of enabled links : 1 Max payload size (MPS) : 256 Multicast group size : 16 MB BAR2 (Prefetch space) : 256 MB BAR4 : 64 MB BAR5 : 8 MB Clock mode slot : Port Clock mode link : Port PCIe slot state : x8, Gen1 (2.5 GT/s) PCIe slot capabilities : x8, Gen2 (5 GT/s) ************************* IXH ADAPTER 0 LINK 0 STATE ************************* Link 0 uptime : 3381 seconds Link 0 state : ENABLED Link 0 state : x8, Gen1 (2.5 GT/s) Link 0 required : x8, Gen1 (2.5 GT/s) Link 0 capabilities : x8, Gen1 (2.5 GT/s) Link 0 cable inserted : 1 Link 0 active : 1 Link 0 configuration : NTB **************************** IXH ADAPTER 0 STATUS **************************** Chip temperature : 77 C *************** IXH ADAPTER 0, PARTNER INFORMATION FOR LINK 0 *************** Partner board type : IXS600 Partner switch no : TOP, Port 3 Partner number of ports : 8 ***************************** TEST OF ADAPTER 0 ***************************** OK: IXH chip alive in adapter 0. [WARN] IXH Adapter 0 - PCIe slot link speed is only Gen1 OK: Link alive in adapter 0. ==> Local adapter 0 has 1 warnings. ==> Local adapter 0 ok. [WARN] Node 8 not reachable, but is an entry in the dishosts.conf file [WARN] Node 12 not reachable, but is an entry in the dishosts.conf file [WARN] Node 16 not reachable, but is an entry in the dishosts.conf file [WARN] Node 20 not reachable, but is an entry in the dishosts.conf file [WARN] Node 24 not reachable, but is an entry in the dishosts.conf file [WARN] Node 28 not reachable, but is an entry in the dishosts.conf file [WARN] Node 32 not reachable, but is an entry in the dishosts.conf file [WARN] Node 36 not reachable, but is an entry in the dishosts.conf file [WARN] Node 40 not reachable, but is an entry in the dishosts.conf file [WARN] Node 44 not reachable, but is an entry in the dishosts.conf file [WARN] Node 48 not reachable, but is an entry in the dishosts.conf file [WARN] Node 52 not reachable, but is an entry in the dishosts.conf file [WARN] Node 56 not reachable, but is an entry in the dishosts.conf file [WARN] Node 60 not reachable, but is an entry in the dishosts.conf file [WARN] Node 64 not reachable, but is an entry in the dishosts.conf file [WARN] Node 80 not reachable, but is an entry in the dishosts.conf file [WARN] Node 84 not reachable, but is an entry in the dishosts.conf file [WARN] Node 88 not reachable, but is an entry in the dishosts.conf file [WARN] Node 96 not reachable, but is an entry in the dishosts.conf file [WARN] Node 100 not reachable, but is an entry in the dishosts.conf file [WARN] Node 104 not reachable, but is an entry in the dishosts.conf file ************************ TOPOLOGY SEEN FROM ADAPTER 0 ************************ Adapters found: 3 ----- List of all nodes found: Nodes detected: 0068 0072 0076 *********************** SESSION STATUS FROM ADAPTER 0 *********************** Node 68: Session valid Node 72: Session valid Node 76: Session valid ---------------------------------- dis_diag discovered 0 note(s). dis_diag discovered 22 warning(s). dis_diag discovered 0 error(s). TEST RESULT: *PASSED*