dis_status 2.0 - 2017-09-29 Found 3 configured adapter(s) Gathering information on adapter 0 COMMAND: /opt/DIS/sbin/dis_diag -a 0 ================================================================================ Dolphin diagnostic tool -- dis_diag version 5.7.0 (Tue Nov 20 09:15:53 PST 2018) ================================================================================ dis_diag compiled in 64 bit mode Driver : Dolphin IRM (GX) 5.7.0 Aug 8th 2018 (rev 8a53628) Date : Mon Oct 14 15:55:27 PDT 2019 System : Linux h1cdsrfm 3.0.8 #2 SMP Fri Mar 4 14:45:06 CST 2016 x86_64 Intel(R) Xeon(R) CPU E5-2640 v4 @ 2.40GHz GenuineIntel GNU/Linux Number of configured local adapters found: 1 Adapter 0 > Type : IXH611 Mode : NTB NodeId : 96 Serial number : IXH611-CE-002365 IXH chip family : IDT_LOGAN IXH chip vendorId : 0x111d IXH chip device : 0x8091 IXH chip revision : 0x2 (ZC) EEPROM version : 08 EEPROM vendor info : 0x0000 EEPROM swmode[3:0] : 0010 EEPROM images : 03 Card revision : CE Topology type : Switch Topology Autodetect : Yes Number of enabled links : 1 Max payload size (MPS) : 256 Multicast group size : 16 MB BAR2 (Prefetch space) : 256 MB BAR4 : 64 MB BAR5 : 8 MB Clock mode slot : Port Clock mode link : Port PCIe slot state : x8, Gen2 (5 GT/s) PCIe slot capabilities : x8, Gen2 (5 GT/s) ************************* IXH ADAPTER 0 LINK 0 STATE ************************* Link 0 uptime : 0 seconds Link 0 state : ENABLED Link 0 state : x8, Gen2 (5 GT/s) Link 0 required : x8, Gen1 (2.5 GT/s) Link 0 capabilities : x8, Gen2 (5 GT/s) Link 0 cable inserted : 1 Link 0 active : 1 Link 0 configuration : NTB **************************** IXH ADAPTER 0 STATUS **************************** Chip temperature : 63 C *************** IXH ADAPTER 0, PARTNER INFORMATION FOR LINK 0 *************** Partner board type : IXS600 Partner switch no : TOP, Port 5 Partner number of ports : 8 ***************************** TEST OF ADAPTER 0 ***************************** OK: IXH chip alive in adapter 0. OK: Link alive in adapter 0. ==> Local adapter 0 ok. [WARN] Node 68 not reachable, but is an entry in the dishosts.conf file [WARN] Node 72 not reachable, but is an entry in the dishosts.conf file [WARN] Node 76 not reachable, but is an entry in the dishosts.conf file [WARN] Node 80 not reachable, but is an entry in the dishosts.conf file [WARN] Node 84 not reachable, but is an entry in the dishosts.conf file [WARN] Node 88 not reachable, but is an entry in the dishosts.conf file [WARN] Node 100 not reachable, but is an entry in the dishosts.conf file [WARN] Node 104 not reachable, but is an entry in the dishosts.conf file ************************ TOPOLOGY SEEN FROM ADAPTER 0 ************************ Adapters found: 16 ----- List of all nodes found: Nodes detected: 0008 0012 0016 0020 0024 0028 0032 0036 0040 0044 0048 0052 0056 0060 Nodes detected: 0064 0096 *********************** SESSION STATUS FROM ADAPTER 0 *********************** Currently no sessions detected ---------------------------------- dis_diag discovered 0 note(s). dis_diag discovered 8 warning(s). dis_diag discovered 0 error(s). TEST RESULT: *PASSED* COMMAND: /opt/DIS/sbin/dis_tool get-error-info 0 0 NACKs error counters - PCIe cable link 0: ----------------------------------------------- Total NACK error cnt ............. 0 NACK DLLP transmitted .......... 0 NACK DLLP received ............. 0 Uncorrectable error counters - PCIe cable link 0: ----------------------------------------------- Total uncorrectable error cnt .... 0 dlperr_cnt ..................... 0 sdoenerr_cnt ................... 0 poisoned_cnt ................... 0 fcperr_cnt ..................... 0 compto_cnt ..................... 0 cabort_cnt ..................... 0 uecomp_cnt ..................... 0 rcvovr_cnt ..................... 0 malformed_cnt .................. 0 ecrc_cnt ....................... 0 ur_cnt ......................... 0 acsv_cnt ....................... 0 uie_cnt ........................ 0 mcblktlp_cnt ................... 0 atopeb_cnt ..................... 0 tlppbe_cnt ..................... 0 Correctable error counters - PCIe cable link 0: --------------------------------------------- Total correctable error cnt ...... 0 rcverr_cnt ..................... 0 badtlp_cnt ..................... 0 baddllp_cnt .................... 0 rplyrovr_cnt ................... 0 rplyto_cnt ..................... 0 advisorynf ..................... 0 cie_cnt ........................ 0 hlo_cnt ........................ 0 NACKs error counters - PCIe SLOT : ----------------------------------------------- Total NACK error cnt ............. 0 NACK DLLP transmitted .......... 0 NACK DLLP received ............. 0 Uncorrectable error counters - PCIe SLOT: ----------------------------------------- Total uncorrectable error cnt .... 0 dlperr_cnt ..................... 0 sdoenerr_cnt ................... 0 poisoned_cnt ................... 0 fcperr_cnt ..................... 0 compto_cnt ..................... 0 cabort_cnt ..................... 0 uecomp_cnt ..................... 0 rcvovr_cnt ..................... 0 malformed_cnt .................. 0 ecrc_cnt ....................... 0 ur_cnt ......................... 0 acsv_cnt ....................... 0 uie_cnt ........................ 0 mcblktlp_cnt ................... 0 atopeb_cnt ..................... 0 tlppbe_cnt ..................... 0 Correctable error counters - PCIe SLOT: --------------------------------------- Total correctable error cnt ...... 0 rcverr_cnt ..................... 0 badtlp_cnt ..................... 0 baddllp_cnt .................... 0 rplyrovr_cnt ................... 0 rplyto_cnt ..................... 0 advisorynf ..................... 0 cie_cnt ........................ 0 hlo_cnt ........................ 0 COMMAND: /opt/DIS/sbin/dis_tool get-drvinfo 0 Adapter Number ....................................... : 0 Local NodeId ......................................... : 96 (0x60) Serial Number ........................................ : 002365 Topology type......................................... : Switch Topology autodetect .................................. : TRUE PCIe link width ...................................... : x8 SCI_LOG (console) messages enabled ................... : FALSE Coherent IO........................................... : Yes Max DMA size ......................................... : 0 (0x0) Cable out ............................................ : NO Pending Any Error..................................... : 0 Pending FATAL error................................... : 0 Debug ................................................ : FALSE Max Cluster NodeId ................................... : 104 Any Error Cnt ........................................ : 1 ReadyToGo flag - link 0 .............................. : TRUE ReadyToGo flag - link 1 .............................. : FALSE ReadyToGo flag - link 2 .............................. : FALSE ReadyToGo flag - link 3 .............................. : FALSE COMMAND: /opt/DIS/sbin/dis_tool get-drv-adapter-info 0 Adapter Number ................................. : 0 Adapter Type ................................... : IXH611 Number of cable ports .......................... : 1 Adapter State .................................. : 0x1 Chip temperature ............................... : 63 C Stop user access enabled (stopUser) ............ : 0 EEPROM initialization done .................... : 1 EEPROM initialization error ................... : 0 EEPROM number of images .........................: 3 EEPROM SWMODE [3:0] .............................: 0010 Clock mode slot .................................: Port Clock mode link .................................: Port GPIO data .......................................: 0x42 Upstream Cable DIP-sw (GPIO).....................: OFF Upstream Edge DIP-sw (GPIO) .....................: OFF EEPROM-select DIP-sw (GPIO) .....................: OFF Link LED yellow (GPIO) ..........................: OFF Link LED green (GPIO) ...........................: ON Cable link state (GPIO) .........................: UP Cable link active (GPIO) ........................: ACTIVE Max payload size (MPS) ..........................: 256 Multicast group size ............................: 16 MB COMMAND: /opt/DIS/sbin/dis_tool get-interruptinfo 0 Interrupt Status for IXH611 adapter 0: -- Normal operation interrupts -- No of dmaDone.............................: 0 No of rem ints............................: 0 No of software packet ints................: 0 No of dma ints............................: 0 No of Doorbell............................: 0 No of unlocked mbx interrupts.............: 0 No of Locked HW mbx interrupts............: 0 -- Error interrupts -- No of fatal errors........................: 0 No of dmaErr..............................: 0 No of handleDMAintr(incl.ErrInt)........... 0 -- IRM internal counters -- No of handleprobeerror.(no int)...........: 0 No of heartbeat alive check failed......... 0 No of user access stopped.................. 0 COMMAND: /opt/DIS/sbin/dis_tool get-link-reset-cnt 0 Link reset reasons: Driver initialization : 0 Link check problems (RTG) : 0 Max link check attempts reached (RTG/FE) : 0 Fatal error detected : 0 Link watchdog failure : 0 IOCTL Enabled SCI link (IM) : 0 IOCTL Disable SCI link (IM) : 0 IOCTL Reset issued by user interface (IM) : 0 IOCTL Retrains issued by user interface (IM) : 0 IOCTL Prepare reconfiguration (IM) : 0 IOCTL Enable routing tables (IM) : 0 Stuck cable link : 0 Stuck link Serdes : 0 Unexpected link width : 0 Unexpected link speed (Gen1) : 0 Generic test module : 0 Production test : 0 Power management : 0 COMMAND: /opt/DIS/sbin/dis_tool get-link-reset-history 0 The last 0 reasons for doing a link reset. Reset reason[0] is the first occurrence COMMAND: /opt/DIS/sbin/dis_diag -V 9 -a 0 ================================================================================ Dolphin diagnostic tool -- dis_diag version 5.7.0 (Tue Nov 20 09:15:53 PST 2018) ================================================================================ dis_diag compiled in 64 bit mode Driver : Dolphin IRM (GX) 5.7.0 Aug 8th 2018 (rev 8a53628) Date : Mon Oct 14 15:55:28 PDT 2019 System : Linux h1cdsrfm 3.0.8 #2 SMP Fri Mar 4 14:45:06 CST 2016 x86_64 Intel(R) Xeon(R) CPU E5-2640 v4 @ 2.40GHz GenuineIntel GNU/Linux Number of configured local adapters found: 1 Adapter 0 > Type : IXH611 Mode : NTB NodeId : 96 Serial number : IXH611-CE-002365 IXH chip family : IDT_LOGAN IXH chip vendorId : 0x111d IXH chip device : 0x8091 IXH chip revision : 0x2 (ZC) EEPROM version : 08 EEPROM vendor info : 0x0000 EEPROM swmode[3:0] : 0010 EEPROM images : 03 Card revision : CE Topology type : Switch Topology Autodetect : Yes Number of enabled links : 1 Max payload size (MPS) : 256 Multicast group size : 16 MB BAR2 (Prefetch space) : 256 MB BAR4 : 64 MB BAR5 : 8 MB Clock mode slot : Port Clock mode link : Port PCIe slot state : x8, Gen2 (5 GT/s) PCIe slot capabilities : x8, Gen2 (5 GT/s) ************************* IXH ADAPTER 0 LINK 0 STATE ************************* Link 0 uptime : 0 seconds Link 0 state : ENABLED Link 0 state : x8, Gen2 (5 GT/s) Link 0 required : x8, Gen1 (2.5 GT/s) Link 0 capabilities : x8, Gen2 (5 GT/s) Link 0 cable inserted : 1 Link 0 active : 1 Link 0 configuration : NTB **************************** IXH ADAPTER 0 STATUS **************************** Chip temperature : 63 C Adapter state : 1 EEPROM init done : 1 *************** IXH ADAPTER 0, PARTNER INFORMATION FOR LINK 0 *************** Partner board type : IXS600 Partner switch no : TOP, Port 5 Partner number of ports : 8 ***************************** TEST OF ADAPTER 0 ***************************** OK: IXH chip alive in adapter 0. OK: Link alive in adapter 0. ==> Local adapter 0 ok. [WARN] Node 68 not reachable, but is an entry in the dishosts.conf file [WARN] Node 72 not reachable, but is an entry in the dishosts.conf file [WARN] Node 76 not reachable, but is an entry in the dishosts.conf file [WARN] Node 80 not reachable, but is an entry in the dishosts.conf file [WARN] Node 84 not reachable, but is an entry in the dishosts.conf file [WARN] Node 88 not reachable, but is an entry in the dishosts.conf file [WARN] Node 100 not reachable, but is an entry in the dishosts.conf file [WARN] Node 104 not reachable, but is an entry in the dishosts.conf file ************************ TOPOLOGY SEEN FROM ADAPTER 0 ************************ Adapters found: 16 ----- List of all nodes found: Nodes detected: 0008 0012 0016 0020 0024 0028 0032 0036 0040 0044 0048 0052 0056 0060 Nodes detected: 0064 0096 ******************* INTERRUPT INFORMATION FOR ADAPTER NO 0 ******************* Interrupt counters for IX adapter 0: No of total interrupt ......................... : 1 No of doorbell interrupts ..................... : 0 No of message interrupts ...................... : 0 No of switch events ........................... : 1 No of slot up events .......................... : 0 No of slot down events ........................ : 0 No of uncorrectable slot error events ......... : 0 No of correctable slot error events ........... : 0 No of unclaimed interrupts .................... : 0 ************** INTERRUPT INFORMATION FOR ADAPTER NO 0 - LINK 0 ************** Interrupt counters for IX adapter 0 - Link 0: No of total interrupt ......................... : 0 No of link up events .......................... : 0 No of link down events ........................ : 0 No of uncorrectable link error events ......... : 0 No of correctable link error events .......... : 0 ******** PCIe CABLE LINK ERROR INFORMATION FOR ADAPTER NO 0 - Link 0 ******** NACK error cnt - PCIe Cable Link 0 ............ : 0 NACK DLLP transmitted ......................: 0 NACK DLLP received .........................: 0 Uncorrectable error cnt - PCIe Cable Link 0 ... : 0 dlperr cnt ................................ : 0 sdoenerr cnt .............................. : 0 poisoned cnt .............................. : 0 fcperr cnt ................................ : 0 compto cnt ................................ : 0 cabort cnt ................................ : 0 uecomp cnt ................................ : 0 rcvovr cnt ................................ : 0 malformed cnt ............................. : 0 ecrc_cnt .................................. : 0 ur_cnt .................................... : 0 acsv_cnt .................................. : 0 uie_cnt ................................... : 0 mcblktlp cnt .............................. : 0 atopeb cnt ................................ : 0 tlppbe cnt ................................ : 0 Correctable error cnt - PCIe Cable Link 0 ..... : 0 rcverr cnt ................................ : 0 badtlp cnt ................................ : 0 baddllp cnt ............................... : 0 rplyrovr cnt .............................. : 0 rplyto cnt ................................ : 0 advisorynf cnt ............................ : 0 cie cnt ................................... : 0 hlo cnt ................................... : 0 **************** PCIe SLOT ERROR INFORMATION FOR ADAPTER NO 0 **************** NACK error cnt - PCIe Slot .................... : 0 NACK DLLP transmitted ......................: 0 NACK DLLP received .........................: 0 Total uncorrectable error cnt - PCIe Slot ..... : 0 dlperr cnt ................................ : 0 sdoenerr cnt .............................. : 0 poisoned cnt .............................. : 0 fcperr cnt ................................ : 0 compto cnt ................................ : 0 cabort cnt ................................ : 0 uecomp cnt ................................ : 0 rcvovr cnt ................................ : 0 malformed cnt ............................. : 0 ecrc_cnt .................................. : 0 ur_cnt .................................... : 0 acsv_cnt .................................. : 0 uie_cnt ................................... : 0 mcblktlp cnt .............................. : 0 atopeb cnt ................................ : 0 tlppbe cnt ................................ : 0 Total correctable error cnt - PCIe Slot ....... : 0 rcverr cnt ................................ : 0 badtlp cnt ................................ : 0 baddllp cnt ............................... : 0 rplyrovr cnt .............................. : 0 rplyto cnt ................................ : 0 advisorynf cnt ............................ : 0 cie cnt ................................... : 0 hlo cnt ................................... : 0 ********************** LINK RESET CNT FOR ADAPTER NO 0 ********************** Driver initialization : 0 Link check problems (RTG) : 0 Max link check attempts reached (RTG/FE) : 0 Fatal error detected : 0 Link watchdog failure : 0 IOCTL Enabled SCI link (IM) : 0 IOCTL Disable SCI link (IM) : 0 IOCTL Reset issued by user interface (IM) : 0 IOCTL Retrain issued by user interface (IM) : 0 IOCTL Prepare reconfiguration (IM) : 0 IOCTL Enable routing tables (IM) : 0 Stuck cable link : 0 Stuck link Serdes : 0 Unexpected link width : 0 Unexpected link speed : 0 Generic test module : 0 Production test : 0 Power management : 0 ******************** LINK RESET HISTORY FOR ADAPTER NO 0 ******************** Reset reason[0] is the first occurrence ************************* DUMP OF ADAPTER NO 0 CSR'S ************************* Adapter 0: dump of CSR's in IXH chip VID, DID, offset 0x0000, has the value 0x8091111d PCICMD, PCISTS, offset 0x0004, has the value 0x00100407 RID, CCODE, offset 0x0008, has the value 0x06800002 CLS, LTIMER, HDR, BIST, offset 0x000c, has the value 0x00800010 BAR0, offset 0x0010, has the value 0xf8801000 BAR1, offset 0x0014, has the value 0x00000000 BAR2, offset 0x0018, has the value 0xd000000c BAR3, offset 0x001c, has the value 0x00000000 BAR4, offset 0x0020, has the value 0xf4000000 BAR5, offset 0x0024, has the value 0xf8000000 SUBVID, SUBID, offset 0x002c, has the value 0x161111c8 EROMBASE, offset 0x0030, has the value 0x00000000 CAPPTR, offset 0x0034, has the value 0x00000040 INTRLINE, INTRPIN, MAXLAT, offset 0x003c, has the value 0x0000010b PCIECAP, offset 0x0040, has the value 0x0002c010 PCIEDCAP, offset 0x0044, has the value 0x00648fe4 PCIEDCTL, offset 0x0048, has the value 0x0000582f PCIELCAP, offset 0x004c, has the value 0x00016c82 PCIELCTL, PCIELSTS, offset 0x0050, has the value 0x00820000 PCIEDCAP2, offset 0x0064, has the value 0x0000041f PCIEDCTL2, PCIEDSTS2, offset 0x0068, has the value 0x00000000 PCIELCAP2, offset 0x006c, has the value 0x00000000 PCIELCTL2, PCIELSTS2, offset 0x0070, has the value 0x00000000 PCICTL, offset 0x0078, has the value 0x00000000 SSIDSSVIDCAP, offset 0x00f0, has the value 0x0000000d SSIDSSVID, offset 0x00f4, has the value 0x161111c8 AERUES, offset 0x0104, has the value 0x00000000 SNUMCAP, offset 0x0180, has the value 0x20010003 SNUMLDW, offset 0x0184, has the value 0x0000093d SNUMUDW, offset 0x0188, has the value 0x00004345 PCIEVCECAP, offset 0x0200, has the value 0x00000000 NTCTL, offset 0x0400, has the value 0x00000003 NTINTSTS, offset 0x0404, has the value 0x00000000 NTINTMASK, offset 0x0408, has the value 0x00000070 NTSDATA, offset 0x040c, has the value 0x00000000 NTGSIGNAL, offset 0x0410, has the value 0x00000000 NTIERRORMASK0, offset 0x0414, has the value 0xffb80000 NTIERRORMASK1, offset 0x0418, has the value 0x01ffffff INDBELLSTS, offset 0x0428, has the value 0x00000000 INDBELLMSK, offset 0x042c, has the value 0x00000000 PTCCTL0, offset 0x0510, has the value 0x00000000 PTCCTL1, offset 0x0514, has the value 0x00000000 PTCDATA, offset 0x0518, has the value 0x00000000 PTCSTS, offset 0x051c, has the value 0x00000000 Adapter 0: dump of switch and status registers in IXH chip SWCTL, offset 0x0000, has the value 0x00190000 BCVSTS, offset 0x0004, has the value 0x00002582 PCLKMODE, offset 0x0008, has the value 0x00000101 SWPART0CTL, offset 0x0100, has the value 0x00000005 SWPART0STS, offset 0x0104, has the value 0x0000c120 SWPART1CTL, offset 0x0120, has the value 0x00000005 SWPART1STS, offset 0x0124, has the value 0x0000d123 SWPORT0CTL, offset 0x0200, has the value 0x00000007 SWPORT0STS, offset 0x0204, has the value 0x700001d3 SWPORT8CTL, offset 0x0300, has the value 0x00000018 SWPORT8STS, offset 0x0304, has the value 0x80000613 SESTS, offset 0x0c00, has the value 0x00000000 SEMSK, offset 0x0c04, has the value 0xfffefe30 SEPMSK, offset 0x0c08, has the value 0x00000000 SELINKUPSTS, offset 0x0c0c, has the value 0x00000000 SELINKUPMSK, offset 0x0c10, has the value 0x00fffefe SELINKDNSTS, offset 0x0c14, has the value 0x00000000 SELINKDNMSK, offset 0x0c18, has the value 0x00fffefe SEFRSTSTS, offset 0x0c1c, has the value 0x00000000 SEFRSTMSK, offset 0x0c20, has the value 0x000000ff SEFHSTSTS, offset 0x0c24, has the value 0x00000000 SEFHSTMSK, offset 0x0c28, has the value 0x000000ff SEGSIGSTS, offset 0x0c30, has the value 0x00000000 SEGSIGMSK, offset 0x0c34, has the value 0x000000ff SSIGNAL, offset 0x0c38, has the value 0x00000000 S4TXLCTL0, offset 0x1084, has the value 0x0004002e S4TXLCTL1, offset 0x1088, has the value 0xcad57860 S5TXLCTL0, offset 0x10a4, has the value 0x0004002e S5TXLCTL1, offset 0x10a8, has the value 0xcad57860 GPIOD, offset 0x1178, has the value 0x00000042 SMBUSSTS, offset 0x1188, has the value 0x2100a0ee GPECTL, offset 0x11b0, has the value 0x00000000 GPESTS, offset 0x11b4, has the value 0x00000000 TMPCTL, offset 0x11d4, has the value 0x00000000 TMPSTS, offset 0x11d8, has the value 0xaa7f7b7e *********************** SESSION STATUS FROM ADAPTER 0 *********************** Currently no sessions detected ************************* DUMP OF IRM CONFIG SETTING ************************* impl_session : TRUE dmaAllowed : TRUE ccoherprop : TRUE stampSize : 0 linkMessagesEnabled : TRUE linkMessagesEnabled : TRUE maxVcNumber : 2048 useNonBlockBarriers : TRUE notesOnLogFileOnly : FALSE linkWatchdogMaxRetries : 1 linkWatchdogPeriod : 2 readyToGoDelay : 200 useOsConfig : FALSE IRM Config : 0x1200 PSB Config : 0x8 LC Config : 0x1 Memory Pre-Alloc Size : 0 MB Disable force link training : 1 Min link width : x8 Min link speed : Gen1 Interrupt polling : Immediate (1000, 100) DMA polling : Immediate (1000, 100) ---------------------------------- dis_diag discovered 0 note(s). dis_diag discovered 8 warning(s). dis_diag discovered 0 error(s). TEST RESULT: *PASSED* Gathering information on adapter 1 COMMAND: /opt/DIS/sbin/dis_diag -a 1 ================================================================================ Dolphin diagnostic tool -- dis_diag version 5.7.0 (Tue Nov 20 09:15:53 PST 2018) ================================================================================ dis_diag compiled in 64 bit mode Driver : Dolphin IRM (GX) 5.7.0 Aug 8th 2018 (rev 8a53628) Date : Mon Oct 14 15:55:29 PDT 2019 System : Linux h1cdsrfm 3.0.8 #2 SMP Fri Mar 4 14:45:06 CST 2016 x86_64 Intel(R) Xeon(R) CPU E5-2640 v4 @ 2.40GHz GenuineIntel GNU/Linux Number of configured local adapters found: 1 Adapter 1 > Type : IXH611 Mode : NTB NodeId : 100 Serial number : IXH611-CE-002344 IXH chip family : IDT_LOGAN IXH chip vendorId : 0x111d IXH chip device : 0x8091 IXH chip revision : 0x2 (ZC) EEPROM version : 08 EEPROM vendor info : 0x0000 EEPROM swmode[3:0] : 0010 EEPROM images : 03 Card revision : CE Topology type : Switch Topology Autodetect : Yes Number of enabled links : 1 Max payload size (MPS) : 256 Multicast group size : 16 MB BAR2 (Prefetch space) : 256 MB BAR4 : 64 MB BAR5 : 8 MB Clock mode slot : Port Clock mode link : Port PCIe slot state : x1, Gen2 (5 GT/s) PCIe slot capabilities : x8, Gen2 (5 GT/s) ************************* IXH ADAPTER 1 LINK 0 STATE ************************* Link 0 uptime : 0 seconds Link 0 state : ENABLED Link 0 state : x8, Gen2 (5 GT/s) Link 0 required : x8, Gen1 (2.5 GT/s) Link 0 capabilities : x8, Gen2 (5 GT/s) Link 0 cable inserted : 1 Link 0 active : 1 Link 0 configuration : NTB **************************** IXH ADAPTER 1 STATUS **************************** Chip temperature : 83 C *************** IXH ADAPTER 1, PARTNER INFORMATION FOR LINK 0 *************** Partner board type : IXS600 Partner switch no : TOP, Port 7 Partner number of ports : 8 ***************************** TEST OF ADAPTER 1 ***************************** OK: IXH chip alive in adapter 1. [WARN] IXH Adapter 1 - PCIe slot link width is only x1 OK: Link alive in adapter 1. ==> Local adapter 1 has 1 warnings. ==> Local adapter 1 ok. [WARN] Node 8 not reachable, but is an entry in the dishosts.conf file [WARN] Node 12 not reachable, but is an entry in the dishosts.conf file [WARN] Node 16 not reachable, but is an entry in the dishosts.conf file [WARN] Node 20 not reachable, but is an entry in the dishosts.conf file [WARN] Node 24 not reachable, but is an entry in the dishosts.conf file [WARN] Node 28 not reachable, but is an entry in the dishosts.conf file [WARN] Node 32 not reachable, but is an entry in the dishosts.conf file [WARN] Node 36 not reachable, but is an entry in the dishosts.conf file [WARN] Node 40 not reachable, but is an entry in the dishosts.conf file [WARN] Node 44 not reachable, but is an entry in the dishosts.conf file [WARN] Node 48 not reachable, but is an entry in the dishosts.conf file [WARN] Node 52 not reachable, but is an entry in the dishosts.conf file [WARN] Node 56 not reachable, but is an entry in the dishosts.conf file [WARN] Node 60 not reachable, but is an entry in the dishosts.conf file [WARN] Node 64 not reachable, but is an entry in the dishosts.conf file [WARN] Node 68 not reachable, but is an entry in the dishosts.conf file [WARN] Node 72 not reachable, but is an entry in the dishosts.conf file [WARN] Node 76 not reachable, but is an entry in the dishosts.conf file [WARN] Node 96 not reachable, but is an entry in the dishosts.conf file [WARN] Node 104 not reachable, but is an entry in the dishosts.conf file ************************ TOPOLOGY SEEN FROM ADAPTER 1 ************************ Adapters found: 4 ----- List of all nodes found: Nodes detected: 0080 0084 0088 0100 *********************** SESSION STATUS FROM ADAPTER 1 *********************** Currently no sessions detected ---------------------------------- dis_diag discovered 0 note(s). dis_diag discovered 21 warning(s). dis_diag discovered 0 error(s). TEST RESULT: *PASSED* COMMAND: /opt/DIS/sbin/dis_tool get-error-info 1 0 NACKs error counters - PCIe cable link 0: ----------------------------------------------- Total NACK error cnt ............. 0 NACK DLLP transmitted .......... 0 NACK DLLP received ............. 0 Uncorrectable error counters - PCIe cable link 0: ----------------------------------------------- Total uncorrectable error cnt .... 0 dlperr_cnt ..................... 0 sdoenerr_cnt ................... 0 poisoned_cnt ................... 0 fcperr_cnt ..................... 0 compto_cnt ..................... 0 cabort_cnt ..................... 0 uecomp_cnt ..................... 0 rcvovr_cnt ..................... 0 malformed_cnt .................. 0 ecrc_cnt ....................... 0 ur_cnt ......................... 0 acsv_cnt ....................... 0 uie_cnt ........................ 0 mcblktlp_cnt ................... 0 atopeb_cnt ..................... 0 tlppbe_cnt ..................... 0 Correctable error counters - PCIe cable link 0: --------------------------------------------- Total correctable error cnt ...... 0 rcverr_cnt ..................... 0 badtlp_cnt ..................... 0 baddllp_cnt .................... 0 rplyrovr_cnt ................... 0 rplyto_cnt ..................... 0 advisorynf ..................... 0 cie_cnt ........................ 0 hlo_cnt ........................ 0 NACKs error counters - PCIe SLOT : ----------------------------------------------- Total NACK error cnt ............. 0 NACK DLLP transmitted .......... 0 NACK DLLP received ............. 0 Uncorrectable error counters - PCIe SLOT: ----------------------------------------- Total uncorrectable error cnt .... 0 dlperr_cnt ..................... 0 sdoenerr_cnt ................... 0 poisoned_cnt ................... 0 fcperr_cnt ..................... 0 compto_cnt ..................... 0 cabort_cnt ..................... 0 uecomp_cnt ..................... 0 rcvovr_cnt ..................... 0 malformed_cnt .................. 0 ecrc_cnt ....................... 0 ur_cnt ......................... 0 acsv_cnt ....................... 0 uie_cnt ........................ 0 mcblktlp_cnt ................... 0 atopeb_cnt ..................... 0 tlppbe_cnt ..................... 0 Correctable error counters - PCIe SLOT: --------------------------------------- Total correctable error cnt ...... 0 rcverr_cnt ..................... 0 badtlp_cnt ..................... 0 baddllp_cnt .................... 0 rplyrovr_cnt ................... 0 rplyto_cnt ..................... 0 advisorynf ..................... 0 cie_cnt ........................ 0 hlo_cnt ........................ 0 COMMAND: /opt/DIS/sbin/dis_tool get-drvinfo 1 Adapter Number ....................................... : 1 Local NodeId ......................................... : 100 (0x64) Serial Number ........................................ : 002344 Topology type......................................... : Switch Topology autodetect .................................. : TRUE PCIe link width ...................................... : x1 SCI_LOG (console) messages enabled ................... : FALSE Coherent IO........................................... : Yes Max DMA size ......................................... : 0 (0x0) Cable out ............................................ : NO Pending Any Error..................................... : 0 Pending FATAL error................................... : 0 Debug ................................................ : FALSE Max Cluster NodeId ................................... : 104 Any Error Cnt ........................................ : 1 ReadyToGo flag - link 0 .............................. : TRUE ReadyToGo flag - link 1 .............................. : FALSE ReadyToGo flag - link 2 .............................. : FALSE ReadyToGo flag - link 3 .............................. : FALSE COMMAND: /opt/DIS/sbin/dis_tool get-drv-adapter-info 1 Adapter Number ................................. : 1 Adapter Type ................................... : IXH611 Number of cable ports .......................... : 1 Adapter State .................................. : 0x1 Chip temperature ............................... : 83 C Stop user access enabled (stopUser) ............ : 0 EEPROM initialization done .................... : 1 EEPROM initialization error ................... : 0 EEPROM number of images .........................: 3 EEPROM SWMODE [3:0] .............................: 0010 Clock mode slot .................................: Port Clock mode link .................................: Port GPIO data .......................................: 0x42 Upstream Cable DIP-sw (GPIO).....................: OFF Upstream Edge DIP-sw (GPIO) .....................: OFF EEPROM-select DIP-sw (GPIO) .....................: OFF Link LED yellow (GPIO) ..........................: OFF Link LED green (GPIO) ...........................: ON Cable link state (GPIO) .........................: UP Cable link active (GPIO) ........................: ACTIVE Max payload size (MPS) ..........................: 256 Multicast group size ............................: 16 MB COMMAND: /opt/DIS/sbin/dis_tool get-interruptinfo 1 Interrupt Status for IXH611 adapter 1: -- Normal operation interrupts -- No of dmaDone.............................: 0 No of rem ints............................: 0 No of software packet ints................: 0 No of dma ints............................: 0 No of Doorbell............................: 0 No of unlocked mbx interrupts.............: 0 No of Locked HW mbx interrupts............: 0 -- Error interrupts -- No of fatal errors........................: 0 No of dmaErr..............................: 0 No of handleDMAintr(incl.ErrInt)........... 0 -- IRM internal counters -- No of handleprobeerror.(no int)...........: 0 No of heartbeat alive check failed......... 0 No of user access stopped.................. 0 COMMAND: /opt/DIS/sbin/dis_tool get-link-reset-cnt 1 Link reset reasons: Driver initialization : 0 Link check problems (RTG) : 0 Max link check attempts reached (RTG/FE) : 0 Fatal error detected : 0 Link watchdog failure : 0 IOCTL Enabled SCI link (IM) : 0 IOCTL Disable SCI link (IM) : 0 IOCTL Reset issued by user interface (IM) : 0 IOCTL Retrains issued by user interface (IM) : 0 IOCTL Prepare reconfiguration (IM) : 0 IOCTL Enable routing tables (IM) : 0 Stuck cable link : 0 Stuck link Serdes : 0 Unexpected link width : 0 Unexpected link speed (Gen1) : 0 Generic test module : 0 Production test : 0 Power management : 0 COMMAND: /opt/DIS/sbin/dis_tool get-link-reset-history 1 The last 0 reasons for doing a link reset. Reset reason[0] is the first occurrence COMMAND: /opt/DIS/sbin/dis_diag -V 9 -a 1 ================================================================================ Dolphin diagnostic tool -- dis_diag version 5.7.0 (Tue Nov 20 09:15:53 PST 2018) ================================================================================ dis_diag compiled in 64 bit mode Driver : Dolphin IRM (GX) 5.7.0 Aug 8th 2018 (rev 8a53628) Date : Mon Oct 14 15:55:29 PDT 2019 System : Linux h1cdsrfm 3.0.8 #2 SMP Fri Mar 4 14:45:06 CST 2016 x86_64 Intel(R) Xeon(R) CPU E5-2640 v4 @ 2.40GHz GenuineIntel GNU/Linux Number of configured local adapters found: 1 Adapter 1 > Type : IXH611 Mode : NTB NodeId : 100 Serial number : IXH611-CE-002344 IXH chip family : IDT_LOGAN IXH chip vendorId : 0x111d IXH chip device : 0x8091 IXH chip revision : 0x2 (ZC) EEPROM version : 08 EEPROM vendor info : 0x0000 EEPROM swmode[3:0] : 0010 EEPROM images : 03 Card revision : CE Topology type : Switch Topology Autodetect : Yes Number of enabled links : 1 Max payload size (MPS) : 256 Multicast group size : 16 MB BAR2 (Prefetch space) : 256 MB BAR4 : 64 MB BAR5 : 8 MB Clock mode slot : Port Clock mode link : Port PCIe slot state : x1, Gen2 (5 GT/s) PCIe slot capabilities : x8, Gen2 (5 GT/s) ************************* IXH ADAPTER 1 LINK 0 STATE ************************* Link 0 uptime : 0 seconds Link 0 state : ENABLED Link 0 state : x8, Gen2 (5 GT/s) Link 0 required : x8, Gen1 (2.5 GT/s) Link 0 capabilities : x8, Gen2 (5 GT/s) Link 0 cable inserted : 1 Link 0 active : 1 Link 0 configuration : NTB **************************** IXH ADAPTER 1 STATUS **************************** Chip temperature : 83 C Adapter state : 1 EEPROM init done : 1 *************** IXH ADAPTER 1, PARTNER INFORMATION FOR LINK 0 *************** Partner board type : IXS600 Partner switch no : TOP, Port 7 Partner number of ports : 8 ***************************** TEST OF ADAPTER 1 ***************************** OK: IXH chip alive in adapter 1. [WARN] IXH Adapter 1 - PCIe slot link width is only x1 OK: Link alive in adapter 1. ==> Local adapter 1 has 1 warnings. ==> Local adapter 1 ok. [WARN] Node 8 not reachable, but is an entry in the dishosts.conf file [WARN] Node 12 not reachable, but is an entry in the dishosts.conf file [WARN] Node 16 not reachable, but is an entry in the dishosts.conf file [WARN] Node 20 not reachable, but is an entry in the dishosts.conf file [WARN] Node 24 not reachable, but is an entry in the dishosts.conf file [WARN] Node 28 not reachable, but is an entry in the dishosts.conf file [WARN] Node 32 not reachable, but is an entry in the dishosts.conf file [WARN] Node 36 not reachable, but is an entry in the dishosts.conf file [WARN] Node 40 not reachable, but is an entry in the dishosts.conf file [WARN] Node 44 not reachable, but is an entry in the dishosts.conf file [WARN] Node 48 not reachable, but is an entry in the dishosts.conf file [WARN] Node 52 not reachable, but is an entry in the dishosts.conf file [WARN] Node 56 not reachable, but is an entry in the dishosts.conf file [WARN] Node 60 not reachable, but is an entry in the dishosts.conf file [WARN] Node 64 not reachable, but is an entry in the dishosts.conf file [WARN] Node 68 not reachable, but is an entry in the dishosts.conf file [WARN] Node 72 not reachable, but is an entry in the dishosts.conf file [WARN] Node 76 not reachable, but is an entry in the dishosts.conf file [WARN] Node 96 not reachable, but is an entry in the dishosts.conf file [WARN] Node 104 not reachable, but is an entry in the dishosts.conf file ************************ TOPOLOGY SEEN FROM ADAPTER 1 ************************ Adapters found: 4 ----- List of all nodes found: Nodes detected: 0080 0084 0088 0100 ******************* INTERRUPT INFORMATION FOR ADAPTER NO 1 ******************* Interrupt counters for IX adapter 1: No of total interrupt ......................... : 1 No of doorbell interrupts ..................... : 0 No of message interrupts ...................... : 0 No of switch events ........................... : 1 No of slot up events .......................... : 0 No of slot down events ........................ : 0 No of uncorrectable slot error events ......... : 0 No of correctable slot error events ........... : 0 No of unclaimed interrupts .................... : 0 ************** INTERRUPT INFORMATION FOR ADAPTER NO 1 - LINK 0 ************** Interrupt counters for IX adapter 1 - Link 0: No of total interrupt ......................... : 0 No of link up events .......................... : 0 No of link down events ........................ : 0 No of uncorrectable link error events ......... : 0 No of correctable link error events .......... : 0 ******** PCIe CABLE LINK ERROR INFORMATION FOR ADAPTER NO 1 - Link 0 ******** NACK error cnt - PCIe Cable Link 0 ............ : 0 NACK DLLP transmitted ......................: 0 NACK DLLP received .........................: 0 Uncorrectable error cnt - PCIe Cable Link 0 ... : 0 dlperr cnt ................................ : 0 sdoenerr cnt .............................. : 0 poisoned cnt .............................. : 0 fcperr cnt ................................ : 0 compto cnt ................................ : 0 cabort cnt ................................ : 0 uecomp cnt ................................ : 0 rcvovr cnt ................................ : 0 malformed cnt ............................. : 0 ecrc_cnt .................................. : 0 ur_cnt .................................... : 0 acsv_cnt .................................. : 0 uie_cnt ................................... : 0 mcblktlp cnt .............................. : 0 atopeb cnt ................................ : 0 tlppbe cnt ................................ : 0 Correctable error cnt - PCIe Cable Link 0 ..... : 0 rcverr cnt ................................ : 0 badtlp cnt ................................ : 0 baddllp cnt ............................... : 0 rplyrovr cnt .............................. : 0 rplyto cnt ................................ : 0 advisorynf cnt ............................ : 0 cie cnt ................................... : 0 hlo cnt ................................... : 0 **************** PCIe SLOT ERROR INFORMATION FOR ADAPTER NO 1 **************** NACK error cnt - PCIe Slot .................... : 0 NACK DLLP transmitted ......................: 0 NACK DLLP received .........................: 0 Total uncorrectable error cnt - PCIe Slot ..... : 0 dlperr cnt ................................ : 0 sdoenerr cnt .............................. : 0 poisoned cnt .............................. : 0 fcperr cnt ................................ : 0 compto cnt ................................ : 0 cabort cnt ................................ : 0 uecomp cnt ................................ : 0 rcvovr cnt ................................ : 0 malformed cnt ............................. : 0 ecrc_cnt .................................. : 0 ur_cnt .................................... : 0 acsv_cnt .................................. : 0 uie_cnt ................................... : 0 mcblktlp cnt .............................. : 0 atopeb cnt ................................ : 0 tlppbe cnt ................................ : 0 Total correctable error cnt - PCIe Slot ....... : 0 rcverr cnt ................................ : 0 badtlp cnt ................................ : 0 baddllp cnt ............................... : 0 rplyrovr cnt .............................. : 0 rplyto cnt ................................ : 0 advisorynf cnt ............................ : 0 cie cnt ................................... : 0 hlo cnt ................................... : 0 ********************** LINK RESET CNT FOR ADAPTER NO 1 ********************** Driver initialization : 0 Link check problems (RTG) : 0 Max link check attempts reached (RTG/FE) : 0 Fatal error detected : 0 Link watchdog failure : 0 IOCTL Enabled SCI link (IM) : 0 IOCTL Disable SCI link (IM) : 0 IOCTL Reset issued by user interface (IM) : 0 IOCTL Retrain issued by user interface (IM) : 0 IOCTL Prepare reconfiguration (IM) : 0 IOCTL Enable routing tables (IM) : 0 Stuck cable link : 0 Stuck link Serdes : 0 Unexpected link width : 0 Unexpected link speed : 0 Generic test module : 0 Production test : 0 Power management : 0 ******************** LINK RESET HISTORY FOR ADAPTER NO 1 ******************** Reset reason[0] is the first occurrence ************************* DUMP OF ADAPTER NO 1 CSR'S ************************* Adapter 1: dump of CSR's in IXH chip VID, DID, offset 0x0000, has the value 0x8091111d PCICMD, PCISTS, offset 0x0004, has the value 0x00100407 RID, CCODE, offset 0x0008, has the value 0x06800002 CLS, LTIMER, HDR, BIST, offset 0x000c, has the value 0x00800010 BAR0, offset 0x0010, has the value 0xf0801000 BAR1, offset 0x0014, has the value 0x00000000 BAR2, offset 0x0018, has the value 0xc000000c BAR3, offset 0x001c, has the value 0x00000000 BAR4, offset 0x0020, has the value 0xec000000 BAR5, offset 0x0024, has the value 0xf0000000 SUBVID, SUBID, offset 0x002c, has the value 0x161111c8 EROMBASE, offset 0x0030, has the value 0x00000000 CAPPTR, offset 0x0034, has the value 0x00000040 INTRLINE, INTRPIN, MAXLAT, offset 0x003c, has the value 0x00000105 PCIECAP, offset 0x0040, has the value 0x0002c010 PCIEDCAP, offset 0x0044, has the value 0x00008fe4 PCIEDCTL, offset 0x0048, has the value 0x0000582f PCIELCAP, offset 0x004c, has the value 0x00016c82 PCIELCTL, PCIELSTS, offset 0x0050, has the value 0x00120000 PCIEDCAP2, offset 0x0064, has the value 0x0000041f PCIEDCTL2, PCIEDSTS2, offset 0x0068, has the value 0x00000000 PCIELCAP2, offset 0x006c, has the value 0x00000000 PCIELCTL2, PCIELSTS2, offset 0x0070, has the value 0x00000000 PCICTL, offset 0x0078, has the value 0x00000000 SSIDSSVIDCAP, offset 0x00f0, has the value 0x0000000d SSIDSSVID, offset 0x00f4, has the value 0x161111c8 AERUES, offset 0x0104, has the value 0x00000000 SNUMCAP, offset 0x0180, has the value 0x20010003 SNUMLDW, offset 0x0184, has the value 0x00000928 SNUMUDW, offset 0x0188, has the value 0x00004345 PCIEVCECAP, offset 0x0200, has the value 0x00000000 NTCTL, offset 0x0400, has the value 0x00000003 NTINTSTS, offset 0x0404, has the value 0x00000000 NTINTMASK, offset 0x0408, has the value 0x00000070 NTSDATA, offset 0x040c, has the value 0x00000000 NTGSIGNAL, offset 0x0410, has the value 0x00000000 NTIERRORMASK0, offset 0x0414, has the value 0xffb80000 NTIERRORMASK1, offset 0x0418, has the value 0x01ffffff INDBELLSTS, offset 0x0428, has the value 0x00000000 INDBELLMSK, offset 0x042c, has the value 0x00000000 PTCCTL0, offset 0x0510, has the value 0x00000000 PTCCTL1, offset 0x0514, has the value 0x00000000 PTCDATA, offset 0x0518, has the value 0x00000000 PTCSTS, offset 0x051c, has the value 0x00000000 Adapter 1: dump of switch and status registers in IXH chip SWCTL, offset 0x0000, has the value 0x00190000 BCVSTS, offset 0x0004, has the value 0x00002582 PCLKMODE, offset 0x0008, has the value 0x00000101 SWPART0CTL, offset 0x0100, has the value 0x00000005 SWPART0STS, offset 0x0104, has the value 0x0000c120 SWPART1CTL, offset 0x0120, has the value 0x00000005 SWPART1STS, offset 0x0124, has the value 0x0000d123 SWPORT0CTL, offset 0x0200, has the value 0x00000007 SWPORT0STS, offset 0x0204, has the value 0x700001d3 SWPORT8CTL, offset 0x0300, has the value 0x00000018 SWPORT8STS, offset 0x0304, has the value 0x80000613 SESTS, offset 0x0c00, has the value 0x00000000 SEMSK, offset 0x0c04, has the value 0xfffefe30 SEPMSK, offset 0x0c08, has the value 0x00000000 SELINKUPSTS, offset 0x0c0c, has the value 0x00000000 SELINKUPMSK, offset 0x0c10, has the value 0x00fffefe SELINKDNSTS, offset 0x0c14, has the value 0x00000000 SELINKDNMSK, offset 0x0c18, has the value 0x00fffefe SEFRSTSTS, offset 0x0c1c, has the value 0x00000000 SEFRSTMSK, offset 0x0c20, has the value 0x000000ff SEFHSTSTS, offset 0x0c24, has the value 0x00000000 SEFHSTMSK, offset 0x0c28, has the value 0x000000ff SEGSIGSTS, offset 0x0c30, has the value 0x00000000 SEGSIGMSK, offset 0x0c34, has the value 0x000000ff SSIGNAL, offset 0x0c38, has the value 0x00000000 S4TXLCTL0, offset 0x1084, has the value 0x0004002e S4TXLCTL1, offset 0x1088, has the value 0xcad57860 S5TXLCTL0, offset 0x10a4, has the value 0x0004002e S5TXLCTL1, offset 0x10a8, has the value 0xcad57860 GPIOD, offset 0x1178, has the value 0x00000042 SMBUSSTS, offset 0x1188, has the value 0x2100a0ee GPECTL, offset 0x11b0, has the value 0x00000000 GPESTS, offset 0x11b4, has the value 0x00000000 TMPCTL, offset 0x11d4, has the value 0x00000000 TMPSTS, offset 0x11d8, has the value 0xaaa6a1a6 *********************** SESSION STATUS FROM ADAPTER 1 *********************** Currently no sessions detected ************************* DUMP OF IRM CONFIG SETTING ************************* impl_session : TRUE dmaAllowed : TRUE ccoherprop : TRUE stampSize : 0 linkMessagesEnabled : TRUE linkMessagesEnabled : TRUE maxVcNumber : 2048 useNonBlockBarriers : TRUE notesOnLogFileOnly : FALSE linkWatchdogMaxRetries : 1 linkWatchdogPeriod : 2 readyToGoDelay : 200 useOsConfig : FALSE IRM Config : 0x1200 PSB Config : 0x8 LC Config : 0x1 Memory Pre-Alloc Size : 0 MB Disable force link training : 1 Min link width : x8 Min link speed : Gen1 Interrupt polling : Immediate (1000, 100) DMA polling : Immediate (1000, 100) ---------------------------------- dis_diag discovered 0 note(s). dis_diag discovered 21 warning(s). dis_diag discovered 0 error(s). TEST RESULT: *PASSED* Gathering information on adapter 2 COMMAND: /opt/DIS/sbin/dis_diag -a 2 ================================================================================ Dolphin diagnostic tool -- dis_diag version 5.7.0 (Tue Nov 20 09:15:53 PST 2018) ================================================================================ dis_diag compiled in 64 bit mode Driver : Dolphin IRM (GX) 5.7.0 Aug 8th 2018 (rev 8a53628) Date : Mon Oct 14 15:55:30 PDT 2019 System : Linux h1cdsrfm 3.0.8 #2 SMP Fri Mar 4 14:45:06 CST 2016 x86_64 Intel(R) Xeon(R) CPU E5-2640 v4 @ 2.40GHz GenuineIntel GNU/Linux Number of configured local adapters found: 1 Adapter 2 > Type : IXH611 Mode : NTB NodeId : 104 Serial number : IXH611-CE-002348 IXH chip family : IDT_LOGAN IXH chip vendorId : 0x111d IXH chip device : 0x8091 IXH chip revision : 0x2 (ZC) EEPROM version : 08 EEPROM vendor info : 0x0000 EEPROM swmode[3:0] : 0010 EEPROM images : 03 Card revision : CE Topology type : Switch Topology Autodetect : No Number of enabled links : 1 Max payload size (MPS) : 256 Multicast group size : 16 MB BAR2 (Prefetch space) : 256 MB BAR4 : 64 MB BAR5 : 8 MB Clock mode slot : Port Clock mode link : Port PCIe slot state : x1, Gen2 (5 GT/s) PCIe slot capabilities : x8, Gen2 (5 GT/s) ************************* IXH ADAPTER 2 LINK 0 STATE ************************* Link 0 downtime : 709 seconds Link 0 state : DISABLED PROBLEM: Link 0 state : DISABLED Possible explanation(s): - Cable not inserted or faulty. - Remote node not powered. - Switch not powered or properly connected. Link 0 configuration : NTB Link 0 required : x8, Gen1 (2.5 GT/s) Link 0 capabilities : x8, Gen2 (5 GT/s) **************************** IXH ADAPTER 2 STATUS **************************** Chip temperature : 90 C *************** IXH ADAPTER 2, PARTNER INFORMATION FOR LINK 0 *************** Partner information not available ***************************** TEST OF ADAPTER 2 ***************************** OK: IXH chip alive in adapter 2. [WARN] IXH Adapter 2 - PCIe slot link width is only x1 OK: Link alive in adapter 2. ==> Local adapter 2 has 1 warnings. ==> Local adapter 2 ok. [WARN] Node 8 not reachable, but is an entry in the dishosts.conf file [WARN] Node 12 not reachable, but is an entry in the dishosts.conf file [WARN] Node 16 not reachable, but is an entry in the dishosts.conf file [WARN] Node 20 not reachable, but is an entry in the dishosts.conf file [WARN] Node 24 not reachable, but is an entry in the dishosts.conf file [WARN] Node 28 not reachable, but is an entry in the dishosts.conf file [WARN] Node 32 not reachable, but is an entry in the dishosts.conf file [WARN] Node 36 not reachable, but is an entry in the dishosts.conf file [WARN] Node 40 not reachable, but is an entry in the dishosts.conf file [WARN] Node 44 not reachable, but is an entry in the dishosts.conf file [WARN] Node 48 not reachable, but is an entry in the dishosts.conf file [WARN] Node 52 not reachable, but is an entry in the dishosts.conf file [WARN] Node 56 not reachable, but is an entry in the dishosts.conf file [WARN] Node 60 not reachable, but is an entry in the dishosts.conf file [WARN] Node 64 not reachable, but is an entry in the dishosts.conf file [WARN] Node 68 not reachable, but is an entry in the dishosts.conf file [WARN] Node 72 not reachable, but is an entry in the dishosts.conf file [WARN] Node 76 not reachable, but is an entry in the dishosts.conf file [WARN] Node 80 not reachable, but is an entry in the dishosts.conf file [WARN] Node 84 not reachable, but is an entry in the dishosts.conf file [WARN] Node 88 not reachable, but is an entry in the dishosts.conf file [WARN] Node 96 not reachable, but is an entry in the dishosts.conf file [WARN] Node 100 not reachable, but is an entry in the dishosts.conf file ************************ TOPOLOGY SEEN FROM ADAPTER 2 ************************ Adapters found: 1 ----- List of all nodes found: Nodes detected: 0104 *********************** SESSION STATUS FROM ADAPTER 2 *********************** Currently no sessions detected ---------------------------------- dis_diag discovered 0 note(s). dis_diag discovered 24 warning(s). dis_diag discovered 1 error(s). TEST RESULT: *FAILED* COMMAND: /opt/DIS/sbin/dis_tool get-error-info 2 0 NACKs error counters - PCIe cable link 0: ----------------------------------------------- Total NACK error cnt ............. 0 NACK DLLP transmitted .......... 0 NACK DLLP received ............. 0 Uncorrectable error counters - PCIe cable link 0: ----------------------------------------------- Total uncorrectable error cnt .... 0 dlperr_cnt ..................... 0 sdoenerr_cnt ................... 0 poisoned_cnt ................... 0 fcperr_cnt ..................... 0 compto_cnt ..................... 0 cabort_cnt ..................... 0 uecomp_cnt ..................... 0 rcvovr_cnt ..................... 0 malformed_cnt .................. 0 ecrc_cnt ....................... 0 ur_cnt ......................... 0 acsv_cnt ....................... 0 uie_cnt ........................ 0 mcblktlp_cnt ................... 0 atopeb_cnt ..................... 0 tlppbe_cnt ..................... 0 Correctable error counters - PCIe cable link 0: --------------------------------------------- Total correctable error cnt ...... 0 rcverr_cnt ..................... 0 badtlp_cnt ..................... 0 baddllp_cnt .................... 0 rplyrovr_cnt ................... 0 rplyto_cnt ..................... 0 advisorynf ..................... 0 cie_cnt ........................ 0 hlo_cnt ........................ 0 NACKs error counters - PCIe SLOT : ----------------------------------------------- Total NACK error cnt ............. 0 NACK DLLP transmitted .......... 0 NACK DLLP received ............. 0 Uncorrectable error counters - PCIe SLOT: ----------------------------------------- Total uncorrectable error cnt .... 0 dlperr_cnt ..................... 0 sdoenerr_cnt ................... 0 poisoned_cnt ................... 0 fcperr_cnt ..................... 0 compto_cnt ..................... 0 cabort_cnt ..................... 0 uecomp_cnt ..................... 0 rcvovr_cnt ..................... 0 malformed_cnt .................. 0 ecrc_cnt ....................... 0 ur_cnt ......................... 0 acsv_cnt ....................... 0 uie_cnt ........................ 0 mcblktlp_cnt ................... 0 atopeb_cnt ..................... 0 tlppbe_cnt ..................... 0 Correctable error counters - PCIe SLOT: --------------------------------------- Total correctable error cnt ...... 0 rcverr_cnt ..................... 0 badtlp_cnt ..................... 0 baddllp_cnt .................... 0 rplyrovr_cnt ................... 0 rplyto_cnt ..................... 0 advisorynf ..................... 0 cie_cnt ........................ 0 hlo_cnt ........................ 0 COMMAND: /opt/DIS/sbin/dis_tool get-drvinfo 2 Adapter Number ....................................... : 2 Local NodeId ......................................... : 104 (0x68) Serial Number ........................................ : 002348 Topology type......................................... : Switch Topology autodetect .................................. : FALSE PCIe link width ...................................... : x1 SCI_LOG (console) messages enabled ................... : FALSE Coherent IO........................................... : Yes Max DMA size ......................................... : 0 (0x0) Cable out ............................................ : NO Pending Any Error..................................... : 0 Pending FATAL error................................... : 0 Debug ................................................ : FALSE Max Cluster NodeId ................................... : 104 Any Error Cnt ........................................ : 1 ReadyToGo flag - link 0 .............................. : FALSE ReadyToGo flag - link 1 .............................. : FALSE ReadyToGo flag - link 2 .............................. : FALSE ReadyToGo flag - link 3 .............................. : FALSE COMMAND: /opt/DIS/sbin/dis_tool get-drv-adapter-info 2 Adapter Number ................................. : 2 Adapter Type ................................... : IXH611 Number of cable ports .......................... : 1 Adapter State .................................. : 0x2 Chip temperature ............................... : 90 C Stop user access enabled (stopUser) ............ : 0 EEPROM initialization done .................... : 1 EEPROM initialization error ................... : 0 EEPROM number of images .........................: 3 EEPROM SWMODE [3:0] .............................: 0010 Clock mode slot .................................: Port Clock mode link .................................: Port GPIO data .......................................: 0x42 Upstream Cable DIP-sw (GPIO).....................: OFF Upstream Edge DIP-sw (GPIO) .....................: OFF EEPROM-select DIP-sw (GPIO) .....................: OFF Link LED yellow (GPIO) ..........................: OFF Link LED green (GPIO) ...........................: ON Cable link state (GPIO) .........................: UP Cable link active (GPIO) ........................: ACTIVE Max payload size (MPS) ..........................: 256 Multicast group size ............................: 16 MB COMMAND: /opt/DIS/sbin/dis_tool get-interruptinfo 2 Interrupt Status for IXH611 adapter 2: -- Normal operation interrupts -- No of dmaDone.............................: 0 No of rem ints............................: 0 No of software packet ints................: 0 No of dma ints............................: 0 No of Doorbell............................: 0 No of unlocked mbx interrupts.............: 0 No of Locked HW mbx interrupts............: 0 -- Error interrupts -- No of fatal errors........................: 0 No of dmaErr..............................: 0 No of handleDMAintr(incl.ErrInt)........... 0 -- IRM internal counters -- No of handleprobeerror.(no int)...........: 0 No of heartbeat alive check failed......... 0 No of user access stopped.................. 0 COMMAND: /opt/DIS/sbin/dis_tool get-link-reset-cnt 2 Link reset reasons: Driver initialization : 0 Link check problems (RTG) : 0 Max link check attempts reached (RTG/FE) : 0 Fatal error detected : 0 Link watchdog failure : 0 IOCTL Enabled SCI link (IM) : 0 IOCTL Disable SCI link (IM) : 0 IOCTL Reset issued by user interface (IM) : 0 IOCTL Retrains issued by user interface (IM) : 0 IOCTL Prepare reconfiguration (IM) : 0 IOCTL Enable routing tables (IM) : 0 Stuck cable link : 0 Stuck link Serdes : 0 Unexpected link width : 0 Unexpected link speed (Gen1) : 0 Generic test module : 0 Production test : 0 Power management : 0 COMMAND: /opt/DIS/sbin/dis_tool get-link-reset-history 2 The last 0 reasons for doing a link reset. Reset reason[0] is the first occurrence COMMAND: /opt/DIS/sbin/dis_diag -V 9 -a 2 ================================================================================ Dolphin diagnostic tool -- dis_diag version 5.7.0 (Tue Nov 20 09:15:53 PST 2018) ================================================================================ dis_diag compiled in 64 bit mode Driver : Dolphin IRM (GX) 5.7.0 Aug 8th 2018 (rev 8a53628) Date : Mon Oct 14 15:55:30 PDT 2019 System : Linux h1cdsrfm 3.0.8 #2 SMP Fri Mar 4 14:45:06 CST 2016 x86_64 Intel(R) Xeon(R) CPU E5-2640 v4 @ 2.40GHz GenuineIntel GNU/Linux Number of configured local adapters found: 1 Adapter 2 > Type : IXH611 Mode : NTB NodeId : 104 Serial number : IXH611-CE-002348 IXH chip family : IDT_LOGAN IXH chip vendorId : 0x111d IXH chip device : 0x8091 IXH chip revision : 0x2 (ZC) EEPROM version : 08 EEPROM vendor info : 0x0000 EEPROM swmode[3:0] : 0010 EEPROM images : 03 Card revision : CE Topology type : Switch Topology Autodetect : No Number of enabled links : 1 Max payload size (MPS) : 256 Multicast group size : 16 MB BAR2 (Prefetch space) : 256 MB BAR4 : 64 MB BAR5 : 8 MB Clock mode slot : Port Clock mode link : Port PCIe slot state : x1, Gen2 (5 GT/s) PCIe slot capabilities : x8, Gen2 (5 GT/s) ************************* IXH ADAPTER 2 LINK 0 STATE ************************* Link 0 downtime : 710 seconds Link 0 state : DISABLED PROBLEM: Link 0 state : DISABLED Possible explanation(s): - Cable not inserted or faulty. - Remote node not powered. - Switch not powered or properly connected. Link 0 configuration : NTB Link 0 required : x8, Gen1 (2.5 GT/s) Link 0 capabilities : x8, Gen2 (5 GT/s) **************************** IXH ADAPTER 2 STATUS **************************** Chip temperature : 90 C Adapter state : 2 EEPROM init done : 1 *************** IXH ADAPTER 2, PARTNER INFORMATION FOR LINK 0 *************** Partner information not available ***************************** TEST OF ADAPTER 2 ***************************** OK: IXH chip alive in adapter 2. [WARN] IXH Adapter 2 - PCIe slot link width is only x1 OK: Link alive in adapter 2. ==> Local adapter 2 has 1 warnings. ==> Local adapter 2 ok. [WARN] Node 8 not reachable, but is an entry in the dishosts.conf file [WARN] Node 12 not reachable, but is an entry in the dishosts.conf file [WARN] Node 16 not reachable, but is an entry in the dishosts.conf file [WARN] Node 20 not reachable, but is an entry in the dishosts.conf file [WARN] Node 24 not reachable, but is an entry in the dishosts.conf file [WARN] Node 28 not reachable, but is an entry in the dishosts.conf file [WARN] Node 32 not reachable, but is an entry in the dishosts.conf file [WARN] Node 36 not reachable, but is an entry in the dishosts.conf file [WARN] Node 40 not reachable, but is an entry in the dishosts.conf file [WARN] Node 44 not reachable, but is an entry in the dishosts.conf file [WARN] Node 48 not reachable, but is an entry in the dishosts.conf file [WARN] Node 52 not reachable, but is an entry in the dishosts.conf file [WARN] Node 56 not reachable, but is an entry in the dishosts.conf file [WARN] Node 60 not reachable, but is an entry in the dishosts.conf file [WARN] Node 64 not reachable, but is an entry in the dishosts.conf file [WARN] Node 68 not reachable, but is an entry in the dishosts.conf file [WARN] Node 72 not reachable, but is an entry in the dishosts.conf file [WARN] Node 76 not reachable, but is an entry in the dishosts.conf file [WARN] Node 80 not reachable, but is an entry in the dishosts.conf file [WARN] Node 84 not reachable, but is an entry in the dishosts.conf file [WARN] Node 88 not reachable, but is an entry in the dishosts.conf file [WARN] Node 96 not reachable, but is an entry in the dishosts.conf file [WARN] Node 100 not reachable, but is an entry in the dishosts.conf file ************************ TOPOLOGY SEEN FROM ADAPTER 2 ************************ Adapters found: 1 ----- List of all nodes found: Nodes detected: 0104 ******************* INTERRUPT INFORMATION FOR ADAPTER NO 2 ******************* Interrupt counters for IX adapter 2: No of total interrupt ......................... : 0 No of doorbell interrupts ..................... : 0 No of message interrupts ...................... : 0 No of switch events ........................... : 0 No of slot up events .......................... : 0 No of slot down events ........................ : 0 No of uncorrectable slot error events ......... : 0 No of correctable slot error events ........... : 0 No of unclaimed interrupts .................... : 0 ************** INTERRUPT INFORMATION FOR ADAPTER NO 2 - LINK 0 ************** Interrupt counters for IX adapter 2 - Link 0: No of total interrupt ......................... : 0 No of link up events .......................... : 0 No of link down events ........................ : 0 No of uncorrectable link error events ......... : 0 No of correctable link error events .......... : 0 ******** PCIe CABLE LINK ERROR INFORMATION FOR ADAPTER NO 2 - Link 0 ******** NACK error cnt - PCIe Cable Link 0 ............ : 0 NACK DLLP transmitted ......................: 0 NACK DLLP received .........................: 0 Uncorrectable error cnt - PCIe Cable Link 0 ... : 0 dlperr cnt ................................ : 0 sdoenerr cnt .............................. : 0 poisoned cnt .............................. : 0 fcperr cnt ................................ : 0 compto cnt ................................ : 0 cabort cnt ................................ : 0 uecomp cnt ................................ : 0 rcvovr cnt ................................ : 0 malformed cnt ............................. : 0 ecrc_cnt .................................. : 0 ur_cnt .................................... : 0 acsv_cnt .................................. : 0 uie_cnt ................................... : 0 mcblktlp cnt .............................. : 0 atopeb cnt ................................ : 0 tlppbe cnt ................................ : 0 Correctable error cnt - PCIe Cable Link 0 ..... : 0 rcverr cnt ................................ : 0 badtlp cnt ................................ : 0 baddllp cnt ............................... : 0 rplyrovr cnt .............................. : 0 rplyto cnt ................................ : 0 advisorynf cnt ............................ : 0 cie cnt ................................... : 0 hlo cnt ................................... : 0 **************** PCIe SLOT ERROR INFORMATION FOR ADAPTER NO 2 **************** NACK error cnt - PCIe Slot .................... : 0 NACK DLLP transmitted ......................: 0 NACK DLLP received .........................: 0 Total uncorrectable error cnt - PCIe Slot ..... : 0 dlperr cnt ................................ : 0 sdoenerr cnt .............................. : 0 poisoned cnt .............................. : 0 fcperr cnt ................................ : 0 compto cnt ................................ : 0 cabort cnt ................................ : 0 uecomp cnt ................................ : 0 rcvovr cnt ................................ : 0 malformed cnt ............................. : 0 ecrc_cnt .................................. : 0 ur_cnt .................................... : 0 acsv_cnt .................................. : 0 uie_cnt ................................... : 0 mcblktlp cnt .............................. : 0 atopeb cnt ................................ : 0 tlppbe cnt ................................ : 0 Total correctable error cnt - PCIe Slot ....... : 0 rcverr cnt ................................ : 0 badtlp cnt ................................ : 0 baddllp cnt ............................... : 0 rplyrovr cnt .............................. : 0 rplyto cnt ................................ : 0 advisorynf cnt ............................ : 0 cie cnt ................................... : 0 hlo cnt ................................... : 0 ********************** LINK RESET CNT FOR ADAPTER NO 2 ********************** Driver initialization : 0 Link check problems (RTG) : 0 Max link check attempts reached (RTG/FE) : 0 Fatal error detected : 0 Link watchdog failure : 0 IOCTL Enabled SCI link (IM) : 0 IOCTL Disable SCI link (IM) : 0 IOCTL Reset issued by user interface (IM) : 0 IOCTL Retrain issued by user interface (IM) : 0 IOCTL Prepare reconfiguration (IM) : 0 IOCTL Enable routing tables (IM) : 0 Stuck cable link : 0 Stuck link Serdes : 0 Unexpected link width : 0 Unexpected link speed : 0 Generic test module : 0 Production test : 0 Power management : 0 ******************** LINK RESET HISTORY FOR ADAPTER NO 2 ******************** Reset reason[0] is the first occurrence ************************* DUMP OF ADAPTER NO 2 CSR'S ************************* Adapter 2: dump of CSR's in IXH chip VID, DID, offset 0x0000, has the value 0x8091111d PCICMD, PCISTS, offset 0x0004, has the value 0x00100407 RID, CCODE, offset 0x0008, has the value 0x06800002 CLS, LTIMER, HDR, BIST, offset 0x000c, has the value 0x00800010 BAR0, offset 0x0010, has the value 0xe8801000 BAR1, offset 0x0014, has the value 0x00000000 BAR2, offset 0x0018, has the value 0xb000000c BAR3, offset 0x001c, has the value 0x00000000 BAR4, offset 0x0020, has the value 0xe4000000 BAR5, offset 0x0024, has the value 0xe8000000 SUBVID, SUBID, offset 0x002c, has the value 0x161111c8 EROMBASE, offset 0x0030, has the value 0x00000000 CAPPTR, offset 0x0034, has the value 0x00000040 INTRLINE, INTRPIN, MAXLAT, offset 0x003c, has the value 0x00000105 PCIECAP, offset 0x0040, has the value 0x0002c010 PCIEDCAP, offset 0x0044, has the value 0x00008fe4 PCIEDCTL, offset 0x0048, has the value 0x0000582f PCIELCAP, offset 0x004c, has the value 0x00016c82 PCIELCTL, PCIELSTS, offset 0x0050, has the value 0x00120000 PCIEDCAP2, offset 0x0064, has the value 0x0000041f PCIEDCTL2, PCIEDSTS2, offset 0x0068, has the value 0x00000000 PCIELCAP2, offset 0x006c, has the value 0x00000000 PCIELCTL2, PCIELSTS2, offset 0x0070, has the value 0x00000000 PCICTL, offset 0x0078, has the value 0x00000000 SSIDSSVIDCAP, offset 0x00f0, has the value 0x0000000d SSIDSSVID, offset 0x00f4, has the value 0x161111c8 AERUES, offset 0x0104, has the value 0x00000000 SNUMCAP, offset 0x0180, has the value 0x20010003 SNUMLDW, offset 0x0184, has the value 0x0000092c SNUMUDW, offset 0x0188, has the value 0x00004345 PCIEVCECAP, offset 0x0200, has the value 0x00000000 NTCTL, offset 0x0400, has the value 0x00000003 NTINTSTS, offset 0x0404, has the value 0x00000000 NTINTMASK, offset 0x0408, has the value 0x00000070 NTSDATA, offset 0x040c, has the value 0x00000000 NTGSIGNAL, offset 0x0410, has the value 0x00000000 NTIERRORMASK0, offset 0x0414, has the value 0xffb80000 NTIERRORMASK1, offset 0x0418, has the value 0x01ffffff INDBELLSTS, offset 0x0428, has the value 0x00000000 INDBELLMSK, offset 0x042c, has the value 0x00000000 PTCCTL0, offset 0x0510, has the value 0x00000000 PTCCTL1, offset 0x0514, has the value 0x00000000 PTCDATA, offset 0x0518, has the value 0x00000000 PTCSTS, offset 0x051c, has the value 0x00000000 Adapter 2: dump of switch and status registers in IXH chip SWCTL, offset 0x0000, has the value 0x00190000 BCVSTS, offset 0x0004, has the value 0x00002582 PCLKMODE, offset 0x0008, has the value 0x00000101 SWPART0CTL, offset 0x0100, has the value 0x00000005 SWPART0STS, offset 0x0104, has the value 0x0000c120 SWPART1CTL, offset 0x0120, has the value 0x00000005 SWPART1STS, offset 0x0124, has the value 0x0000d123 SWPORT0CTL, offset 0x0200, has the value 0x00000007 SWPORT0STS, offset 0x0204, has the value 0x700001d3 SWPORT8CTL, offset 0x0300, has the value 0x00000018 SWPORT8STS, offset 0x0304, has the value 0x80000613 SESTS, offset 0x0c00, has the value 0x00010000 SEMSK, offset 0x0c04, has the value 0xfffffe30 SEPMSK, offset 0x0c08, has the value 0x00000000 SELINKUPSTS, offset 0x0c0c, has the value 0x00000000 SELINKUPMSK, offset 0x0c10, has the value 0x00fffefe SELINKDNSTS, offset 0x0c14, has the value 0x00000000 SELINKDNMSK, offset 0x0c18, has the value 0x00fffefe SEFRSTSTS, offset 0x0c1c, has the value 0x00000000 SEFRSTMSK, offset 0x0c20, has the value 0x000000ff SEFHSTSTS, offset 0x0c24, has the value 0x00000000 SEFHSTMSK, offset 0x0c28, has the value 0x000000ff SEGSIGSTS, offset 0x0c30, has the value 0x00000000 SEGSIGMSK, offset 0x0c34, has the value 0x000000ff SSIGNAL, offset 0x0c38, has the value 0x00000000 S4TXLCTL0, offset 0x1084, has the value 0x0004002e S4TXLCTL1, offset 0x1088, has the value 0xcad57872 S5TXLCTL0, offset 0x10a4, has the value 0x0004002e S5TXLCTL1, offset 0x10a8, has the value 0xcad57872 GPIOD, offset 0x1178, has the value 0x00000042 SMBUSSTS, offset 0x1188, has the value 0x2100a0ee GPECTL, offset 0x11b0, has the value 0x00000000 GPESTS, offset 0x11b4, has the value 0x00000000 TMPCTL, offset 0x11d4, has the value 0x00000000 TMPSTS, offset 0x11d8, has the value 0xaab6b1b5 *********************** SESSION STATUS FROM ADAPTER 2 *********************** Currently no sessions detected ************************* DUMP OF IRM CONFIG SETTING ************************* impl_session : TRUE dmaAllowed : TRUE ccoherprop : TRUE stampSize : 0 linkMessagesEnabled : TRUE linkMessagesEnabled : TRUE maxVcNumber : 2048 useNonBlockBarriers : TRUE notesOnLogFileOnly : FALSE linkWatchdogMaxRetries : 1 linkWatchdogPeriod : 2 readyToGoDelay : 200 useOsConfig : FALSE IRM Config : 0x1200 PSB Config : 0x8 LC Config : 0x1 Memory Pre-Alloc Size : 0 MB Disable force link training : 1 Min link width : x8 Min link speed : Gen1 Interrupt polling : Immediate (1000, 100) DMA polling : Immediate (1000, 100) ---------------------------------- dis_diag discovered 0 note(s). dis_diag discovered 24 warning(s). dis_diag discovered 1 error(s). TEST RESULT: *FAILED* COMMAND: /bin/dmesg [ 0.000000] Initializing cgroup subsys cpuset [ 0.000000] Initializing cgroup subsys cpu [ 0.000000] Linux version 3.0.8 (root@x2boot3) (gcc version 4.4.3 (Gentoo 4.4.3-r2 p1.2) ) #2 SMP Fri Mar 4 14:45:06 CST 2016 [ 0.000000] Command line: ip=dhcp ro root=/dev/nfs nfsroot=10.101.0.12:/diskless/root BOOT_IMAGE=bzImage-3.0.8-cs [ 0.000000] BIOS-provided physical RAM map: [ 0.000000] BIOS-e820: 0000000000000000 - 000000000009b000 (usable) [ 0.000000] BIOS-e820: 000000000009b000 - 00000000000a0000 (reserved) [ 0.000000] BIOS-e820: 00000000000e0000 - 0000000000100000 (reserved) [ 0.000000] BIOS-e820: 0000000000100000 - 0000000078f58000 (usable) [ 0.000000] BIOS-e820: 0000000078f58000 - 00000000798a6000 (reserved) [ 0.000000] BIOS-e820: 00000000798a6000 - 0000000079d45000 (ACPI NVS) [ 0.000000] BIOS-e820: 0000000079d45000 - 0000000090000000 (reserved) [ 0.000000] BIOS-e820: 00000000fed1c000 - 00000000fed45000 (reserved) [ 0.000000] BIOS-e820: 00000000ff000000 - 0000000100000000 (reserved) [ 0.000000] BIOS-e820: 0000000100000000 - 0000000880000000 (usable) [ 0.000000] NX (Execute Disable) protection: active [ 0.000000] DMI 3.0 present. [ 0.000000] DMI: Supermicro Super Server/X10SRW-F, BIOS 2.0a 08/02/2016 [ 0.000000] e820 update range: 0000000000000000 - 0000000000010000 (usable) ==> (reserved) [ 0.000000] e820 remove range: 00000000000a0000 - 0000000000100000 (usable) [ 0.000000] No AGP bridge found [ 0.000000] last_pfn = 0x880000 max_arch_pfn = 0x400000000 [ 0.000000] MTRR default type: write-back [ 0.000000] MTRR fixed ranges enabled: [ 0.000000] 00000-9FFFF write-back [ 0.000000] A0000-BFFFF uncachable [ 0.000000] C0000-FFFFF write-protect [ 0.000000] MTRR variable ranges enabled: [ 0.000000] 0 base 000080000000 mask 3FFF80000000 uncachable [ 0.000000] 1 base 380000000000 mask 3FC000000000 uncachable [ 0.000000] 2 base 0000B0000000 mask 3FFFF0000000 write-through [ 0.000000] 3 base 0000C0000000 mask 3FFFE0000000 write-through [ 0.000000] 4 disabled [ 0.000000] 5 disabled [ 0.000000] 6 disabled [ 0.000000] 7 disabled [ 0.000000] 8 disabled [ 0.000000] 9 disabled [ 0.000000] x86 PAT enabled: cpu 0, old 0x7040600070406, new 0x7010600070106 [ 0.000000] last_pfn = 0x78f58 max_arch_pfn = 0x400000000 [ 0.000000] found SMP MP-table at [ffff8800000fce50] fce50 [ 0.000000] initial memory mapped : 0 - 20000000 [ 0.000000] Base memory trampoline at [ffff880000095000] 95000 size 20480 [ 0.000000] Using GB pages for direct mapping [ 0.000000] init_memory_mapping: 0000000000000000-0000000078f58000 [ 0.000000] 0000000000 - 0040000000 page 1G [ 0.000000] 0040000000 - 0078e00000 page 2M [ 0.000000] 0078e00000 - 0078f58000 page 4k [ 0.000000] kernel direct mapping tables up to 78f58000 @ 1fffd000-20000000 [ 0.000000] init_memory_mapping: 0000000100000000-0000000880000000 [ 0.000000] 0100000000 - 0880000000 page 1G [ 0.000000] kernel direct mapping tables up to 880000000 @ 78f57000-78f58000 [ 0.000000] ACPI: RSDP 00000000000f05b0 00024 (v02 SUPERM) [ 0.000000] ACPI: XSDT 00000000798a60a0 000BC (v01 01072009 AMI 00010013) [ 0.000000] ACPI: FACP 00000000798d9838 0010C (v05 SUPERM SMCI--MB 01072009 AMI 00010013) [ 0.000000] ACPI Warning: FADT (revision 5) is longer than ACPI 2.0 version, truncating length 268 to 244 (20110413/tbfadt-288) [ 0.000000] ACPI: DSDT 00000000798a61f0 33641 (v02 SUPERM SMCI--MB 01072009 INTL 20091013) [ 0.000000] ACPI: FACS 0000000079d43f80 00040 [ 0.000000] ACPI: APIC 00000000798d9948 000E4 (v03 SUPERM SMCI--MB 01072009 AMI 00010013) [ 0.000000] ACPI: FPDT 00000000798d9a30 00044 (v01 SUPERM SMCI--MB 01072009 AMI 00010013) [ 0.000000] ACPI: FIDT 00000000798d9a78 0009C (v01 SUPERM SMCI--MB 01072009 AMI 00010013) [ 0.000000] ACPI: SPMI 00000000798d9b18 00040 (v05 SUPERM SMCI--MB 00000000 AMI. 00000000) [ 0.000000] ACPI: MCFG 00000000798d9b58 0003C (v01 SUPERM SMCI--MB 01072009 MSFT 00000097) [ 0.000000] ACPI: UEFI 00000000798d9b98 00042 (v01 SUPERM SMCI--MB 01072009 00000000) [ 0.000000] ACPI: HPET 00000000798d9be0 00038 (v01 SUPERM SMCI--MB 00000001 INTL 20091013) [ 0.000000] ACPI: WDDT 00000000798d9c18 00040 (v01 SUPERM SMCI--MB 00000000 INTL 20091013) [ 0.000000] ACPI: SSDT 00000000798d9c58 1717F (v02 SUPERM PmMgt 00000001 INTL 20120913) [ 0.000000] ACPI: NITR 00000000798f0dd8 00071 (v02 SUPERM SMCI--MB 00000001 INTL 20091013) [ 0.000000] ACPI: SSDT 00000000798f0e50 0264C (v02 SUPERM SpsNm 00000002 INTL 20120913) [ 0.000000] ACPI: SSDT 00000000798f34a0 00064 (v02 SUPERM SpsNvs 00000002 INTL 20120913) [ 0.000000] ACPI: PRAD 00000000798f3508 00102 (v02 SUPERM SMCI--MB 00000002 INTL 20120913) [ 0.000000] ACPI: DMAR 00000000798f3610 000CC (v01 SUPERM SMCI--MB 00000001 INTL 20091013) [ 0.000000] ACPI: HEST 00000000798f36e0 0027C (v01 SUPERM SMCI--MB 00000001 INTL 00000001) [ 0.000000] ACPI: BERT 00000000798f3960 00030 (v01 SUPERM SMCI--MB 00000001 INTL 00000001) [ 0.000000] ACPI: ERST 00000000798f3990 00230 (v01 SUPERM SMCI--MB 00000001 INTL 00000001) [ 0.000000] ACPI: EINJ 00000000798f3bc0 00130 (v01 SUPERM SMCI--MB 00000001 INTL 00000001) [ 0.000000] ACPI: Local APIC address 0xfee00000 [ 0.000000] No NUMA configuration found [ 0.000000] Faking a node at 0000000000000000-0000000880000000 [ 0.000000] Initmem setup node 0 0000000000000000-0000000880000000 [ 0.000000] NODE_DATA [000000087fffb000 - 000000087fffffff] [ 0.000000] [ffffea0000000000-ffffea001dbfffff] PMD -> [ffff88085f600000-ffff88087b5fffff] on node 0 [ 0.000000] Zone PFN ranges: [ 0.000000] DMA 0x00000010 -> 0x00001000 [ 0.000000] DMA32 0x00001000 -> 0x00100000 [ 0.000000] Normal 0x00100000 -> 0x00880000 [ 0.000000] Movable zone start PFN for each node [ 0.000000] early_node_map[3] active PFN ranges [ 0.000000] 0: 0x00000010 -> 0x0000009b [ 0.000000] 0: 0x00000100 -> 0x00078f58 [ 0.000000] 0: 0x00100000 -> 0x00880000 [ 0.000000] On node 0 totalpages: 8359651 [ 0.000000] DMA zone: 56 pages used for memmap [ 0.000000] DMA zone: 6 pages reserved [ 0.000000] DMA zone: 3917 pages, LIFO batch:0 [ 0.000000] DMA32 zone: 14280 pages used for memmap [ 0.000000] DMA32 zone: 477072 pages, LIFO batch:31 [ 0.000000] Normal zone: 107520 pages used for memmap [ 0.000000] Normal zone: 7756800 pages, LIFO batch:31 [ 0.000000] ACPI: PM-Timer IO Port: 0x408 [ 0.000000] ACPI: Local APIC address 0xfee00000 [ 0.000000] ACPI: LAPIC (acpi_id[0x00] lapic_id[0x00] enabled) [ 0.000000] ACPI: LAPIC (acpi_id[0x02] lapic_id[0x02] enabled) [ 0.000000] ACPI: LAPIC (acpi_id[0x04] lapic_id[0x04] enabled) [ 0.000000] ACPI: LAPIC (acpi_id[0x06] lapic_id[0x06] enabled) [ 0.000000] ACPI: LAPIC (acpi_id[0x08] lapic_id[0x08] enabled) [ 0.000000] ACPI: LAPIC (acpi_id[0x10] lapic_id[0x10] enabled) [ 0.000000] ACPI: LAPIC (acpi_id[0x12] lapic_id[0x12] enabled) [ 0.000000] ACPI: LAPIC (acpi_id[0x14] lapic_id[0x14] enabled) [ 0.000000] ACPI: LAPIC (acpi_id[0x16] lapic_id[0x16] enabled) [ 0.000000] ACPI: LAPIC (acpi_id[0x18] lapic_id[0x18] enabled) [ 0.000000] ACPI: LAPIC_NMI (acpi_id[0x00] high edge lint[0x1]) [ 0.000000] ACPI: LAPIC_NMI (acpi_id[0x02] high edge lint[0x1]) [ 0.000000] ACPI: LAPIC_NMI (acpi_id[0x04] high edge lint[0x1]) [ 0.000000] ACPI: LAPIC_NMI (acpi_id[0x06] high edge lint[0x1]) [ 0.000000] ACPI: LAPIC_NMI (acpi_id[0x08] high edge lint[0x1]) [ 0.000000] ACPI: LAPIC_NMI (acpi_id[0x10] high edge lint[0x1]) [ 0.000000] ACPI: LAPIC_NMI (acpi_id[0x12] high edge lint[0x1]) [ 0.000000] ACPI: LAPIC_NMI (acpi_id[0x14] high edge lint[0x1]) [ 0.000000] ACPI: LAPIC_NMI (acpi_id[0x16] high edge lint[0x1]) [ 0.000000] ACPI: LAPIC_NMI (acpi_id[0x18] high edge lint[0x1]) [ 0.000000] ACPI: IOAPIC (id[0x01] address[0xfec00000] gsi_base[0]) [ 0.000000] IOAPIC[0]: apic_id 1, version 32, address 0xfec00000, GSI 0-23 [ 0.000000] ACPI: IOAPIC (id[0x02] address[0xfec01000] gsi_base[24]) [ 0.000000] IOAPIC[1]: apic_id 2, version 32, address 0xfec01000, GSI 24-47 [ 0.000000] ACPI: INT_SRC_OVR (bus 0 bus_irq 0 global_irq 2 dfl dfl) [ 0.000000] ACPI: INT_SRC_OVR (bus 0 bus_irq 9 global_irq 9 high level) [ 0.000000] ACPI: IRQ0 used by override. [ 0.000000] ACPI: IRQ2 used by override. [ 0.000000] ACPI: IRQ9 used by override. [ 0.000000] Using ACPI (MADT) for SMP configuration information [ 0.000000] ACPI: HPET id: 0x8086a701 base: 0xfed00000 [ 0.000000] SMP: Allowing 10 CPUs, 0 hotplug CPUs [ 0.000000] nr_irqs_gsi: 64 [ 0.000000] PM: Registered nosave memory: 000000000009b000 - 00000000000a0000 [ 0.000000] PM: Registered nosave memory: 00000000000a0000 - 00000000000e0000 [ 0.000000] PM: Registered nosave memory: 00000000000e0000 - 0000000000100000 [ 0.000000] PM: Registered nosave memory: 0000000078f58000 - 00000000798a6000 [ 0.000000] PM: Registered nosave memory: 00000000798a6000 - 0000000079d45000 [ 0.000000] PM: Registered nosave memory: 0000000079d45000 - 0000000090000000 [ 0.000000] PM: Registered nosave memory: 0000000090000000 - 00000000fed1c000 [ 0.000000] PM: Registered nosave memory: 00000000fed1c000 - 00000000fed45000 [ 0.000000] PM: Registered nosave memory: 00000000fed45000 - 00000000ff000000 [ 0.000000] PM: Registered nosave memory: 00000000ff000000 - 0000000100000000 [ 0.000000] Allocating PCI resources starting at 90000000 (gap: 90000000:6ed1c000) [ 0.000000] setup_percpu: NR_CPUS:64 nr_cpumask_bits:64 nr_cpu_ids:10 nr_node_ids:1 [ 0.000000] PERCPU: Embedded 24 pages/cpu @ffff88087f000000 s69504 r8192 d20608 u524288 [ 0.000000] pcpu-alloc: s69504 r8192 d20608 u524288 alloc=1*2097152 [ 0.000000] pcpu-alloc: [0] 00 01 02 03 [0] 04 05 06 07 [ 0.000000] pcpu-alloc: [0] 08 09 -- -- [ 0.000000] Built 1 zonelists in Zone order, mobility grouping on. Total pages: 8237789 [ 0.000000] Policy zone: Normal [ 0.000000] Kernel command line: ip=dhcp ro root=/dev/nfs nfsroot=10.101.0.12:/diskless/root BOOT_IMAGE=bzImage-3.0.8-cs [ 0.000000] PID hash table entries: 4096 (order: 3, 32768 bytes) [ 0.000000] xsave/xrstor: enabled xstate_bv 0x7, cntxt size 0x340 [ 0.000000] Checking aperture... [ 0.000000] No AGP bridge found [ 0.000000] Calgary: detecting Calgary via BIOS EBDA area [ 0.000000] Calgary: Unable to locate Rio Grande table in EBDA - bailing! [ 0.000000] Memory: 32900396k/35651584k available (5422k kernel code, 2212980k absent, 538208k reserved, 5299k data, 616k init) [ 0.000000] SLUB: Genslabs=15, HWalign=64, Order=0-3, MinObjects=0, CPUs=10, Nodes=1 [ 0.000000] Hierarchical RCU implementation. [ 0.000000] NR_IRQS:4352 nr_irqs:1168 16 [ 0.000000] Extended CMOS year: 2000 [ 0.000000] Console: colour VGA+ 80x25 [ 0.000000] console [tty0] enabled [ 0.000000] hpet clockevent registered [ 0.000000] Fast TSC calibration using PIT [ 0.001000] Detected 2400.436 MHz processor. [ 0.000002] Calibrating delay loop (skipped), value calculated using timer frequency.. 4800.87 BogoMIPS (lpj=2400436) [ 0.000677] pid_max: default: 32768 minimum: 301 [ 0.003290] Dentry cache hash table entries: 4194304 (order: 13, 33554432 bytes) [ 0.009223] Inode-cache hash table entries: 2097152 (order: 12, 16777216 bytes) [ 0.011920] Mount-cache hash table entries: 256 [ 0.012343] Initializing cgroup subsys cpuacct [ 0.012681] Initializing cgroup subsys freezer [ 0.013039] CPU: Physical Processor ID: 0 [ 0.013373] CPU: Processor Core ID: 0 [ 0.013710] mce: CPU supports 22 MCE banks [ 0.014080] CPU0: Thermal monitoring enabled (TM1) [ 0.014440] using mwait in idle threads. [ 0.014819] ACPI: Core revision 20110413 [ 0.036714] DMAR: Host address width 46 [ 0.037058] DMAR: DRHD base: 0x000000fbffc000 flags: 0x1 [ 0.037400] IOMMU 0: reg_base_addr fbffc000 ver 1:0 cap 8d2078c106f0466 ecap f020de [ 0.038014] DMAR: RMRR base: 0x0000007ba6e000 end: 0x0000007ba7dfff [ 0.038354] DMAR: ATSR flags: 0x0 [ 0.038687] DMAR: RHSA base: 0x000000fbffc000 proximity domain: 0x0 [ 0.039208] Not enabling x2apic, Intr-remapping init failed. [ 0.039547] Switched APIC routing to physical flat. [ 0.040281] ..TIMER: vector=0x30 apic1=0 pin1=2 apic2=-1 pin2=-1 [ 0.050607] CPU0: Intel(R) Xeon(R) CPU E5-2640 v4 @ 2.40GHz stepping 01 [ 0.152686] Performance Events: no PEBS fmt2+, generic architected perfmon, Intel PMU driver. [ 0.161143] ... version: 3 [ 0.161477] ... bit width: 48 [ 0.161813] ... generic registers: 8 [ 0.162148] ... value mask: 0000ffffffffffff [ 0.162485] ... max period: 000000007fffffff [ 0.162823] ... fixed-purpose events: 3 [ 0.163157] ... event mask: 00000007000000ff [ 0.163581] Booting Node 0, Processors #1 [ 0.163713] smpboot cpu 1: start_ip = 95000 [ 0.254676] #2 [ 0.254742] smpboot cpu 2: start_ip = 95000 [ 0.345495] #3 [ 0.345561] smpboot cpu 3: start_ip = 95000 [ 0.436314] #4 [ 0.436379] smpboot cpu 4: start_ip = 95000 [ 0.527231] #5 [ 0.527297] smpboot cpu 5: start_ip = 95000 [ 0.618057] #6 [ 0.618122] smpboot cpu 6: start_ip = 95000 [ 0.708888] #7 [ 0.708953] smpboot cpu 7: start_ip = 95000 [ 0.799714] #8 [ 0.799780] smpboot cpu 8: start_ip = 95000 [ 0.890539] #9 Ok. [ 0.890871] smpboot cpu 9: start_ip = 95000 [ 0.981374] Brought up 10 CPUs [ 0.981708] Total of 10 processors activated (47994.31 BogoMIPS). [ 0.991529] kworker/u:0 used greatest stack depth: 5760 bytes left [ 0.991661] PM: Registering ACPI NVS region at 798a6000 (4845568 bytes) [ 0.991803] Time: 22:42:37 Date: 10/14/19 [ 0.991825] NET: Registered protocol family 16 [ 0.992994] ACPI FADT declares the system doesn't support PCIe ASPM, so disable it [ 0.993606] ACPI: bus type pci registered [ 0.994021] PCI: MMCONFIG for domain 0000 [bus 00-ff] at [mem 0x80000000-0x8fffffff] (base 0x80000000) [ 0.994634] PCI: MMCONFIG at [mem 0x80000000-0x8fffffff] reserved in E820 [ 1.007185] PCI: Using configuration type 1 for base access [ 1.012507] bio: create slab at 0 [ 1.020552] ACPI: EC: Look up EC in DSDT [ 1.039871] [Firmware Bug]: ACPI: BIOS _OSI(Linux) query ignored [ 1.102492] ACPI: Interpreter enabled [ 1.102828] ACPI: (supports S0 S4 S5) [ 1.103354] ACPI: BIOS offers _GTS [ 1.103687] ACPI: If "acpi.gts=1" improves suspend, please notify linux-acpi@vger.kernel.org [ 1.104299] ACPI: Using IOAPIC for interrupt routing [ 1.121618] ACPI: No dock devices found. [ 1.121955] PCI: Using host bridge windows from ACPI; if necessary, use "pci=nocrs" and report a bug [ 2.120501] ACPI: PCI Root Bridge [UNC0] (domain 0000 [bus ff]) [ 2.120929] pci 0000:ff:0b.0: [8086:6f81] type 0 class 0x000880 [ 2.120960] pci 0000:ff:0b.1: [8086:6f36] type 0 class 0x001101 [ 2.120988] pci 0000:ff:0b.2: [8086:6f37] type 0 class 0x001101 [ 2.121015] pci 0000:ff:0b.3: [8086:6f76] type 0 class 0x000880 [ 2.121044] pci 0000:ff:0c.0: [8086:6fe0] type 0 class 0x000880 [ 2.121070] pci 0000:ff:0c.1: [8086:6fe1] type 0 class 0x000880 [ 2.121097] pci 0000:ff:0c.2: [8086:6fe2] type 0 class 0x000880 [ 2.121124] pci 0000:ff:0c.3: [8086:6fe3] type 0 class 0x000880 [ 2.121152] pci 0000:ff:0c.4: [8086:6fe4] type 0 class 0x000880 [ 2.121178] pci 0000:ff:0c.5: [8086:6fe5] type 0 class 0x000880 [ 2.121205] pci 0000:ff:0c.6: [8086:6fe6] type 0 class 0x000880 [ 2.121231] pci 0000:ff:0c.7: [8086:6fe7] type 0 class 0x000880 [ 2.121258] pci 0000:ff:0d.0: [8086:6fe8] type 0 class 0x000880 [ 2.121285] pci 0000:ff:0d.1: [8086:6fe9] type 0 class 0x000880 [ 2.121315] pci 0000:ff:0f.0: [8086:6ff8] type 0 class 0x000880 [ 2.121341] pci 0000:ff:0f.1: [8086:6ff9] type 0 class 0x000880 [ 2.121370] pci 0000:ff:0f.4: [8086:6ffc] type 0 class 0x000880 [ 2.121398] pci 0000:ff:0f.5: [8086:6ffd] type 0 class 0x000880 [ 2.121426] pci 0000:ff:0f.6: [8086:6ffe] type 0 class 0x000880 [ 2.121454] pci 0000:ff:10.0: [8086:6f1d] type 0 class 0x000880 [ 2.121481] pci 0000:ff:10.1: [8086:6f34] type 0 class 0x001101 [ 2.121510] pci 0000:ff:10.5: [8086:6f1e] type 0 class 0x000880 [ 2.121535] pci 0000:ff:10.6: [8086:6f7d] type 0 class 0x001101 [ 2.121561] pci 0000:ff:10.7: [8086:6f1f] type 0 class 0x000880 [ 2.121588] pci 0000:ff:12.0: [8086:6fa0] type 0 class 0x000880 [ 2.121598] pci 0000:ff:12.0: reg 14: [mem 0x00000000-0x0000000f] [ 2.121603] pci 0000:ff:12.0: reg 18: [mem 0x00000000-0x0000003f] [ 2.121608] pci 0000:ff:12.0: reg 1c: [mem 0x00000000-0x0000000f] [ 2.121612] pci 0000:ff:12.0: reg 20: [mem 0x00000000-0x0000003f] [ 2.121617] pci 0000:ff:12.0: reg 24: [mem 0x00000000-0x0000000f] [ 2.121627] pci 0000:ff:12.1: [8086:6f30] type 0 class 0x001101 [ 2.121663] pci 0000:ff:13.0: [8086:6fa8] type 0 class 0x000880 [ 2.121701] pci 0000:ff:13.1: [8086:6f71] type 0 class 0x000880 [ 2.121739] pci 0000:ff:13.2: [8086:6faa] type 0 class 0x000880 [ 2.121776] pci 0000:ff:13.3: [8086:6fab] type 0 class 0x000880 [ 2.121813] pci 0000:ff:13.4: [8086:6fac] type 0 class 0x000880 [ 2.121851] pci 0000:ff:13.5: [8086:6fad] type 0 class 0x000880 [ 2.121888] pci 0000:ff:13.6: [8086:6fae] type 0 class 0x000880 [ 2.121919] pci 0000:ff:13.7: [8086:6faf] type 0 class 0x000880 [ 2.121951] pci 0000:ff:14.0: [8086:6fb0] type 0 class 0x000880 [ 2.121989] pci 0000:ff:14.1: [8086:6fb1] type 0 class 0x000880 [ 2.122027] pci 0000:ff:14.2: [8086:6fb2] type 0 class 0x000880 [ 2.122064] pci 0000:ff:14.3: [8086:6fb3] type 0 class 0x000880 [ 2.122101] pci 0000:ff:14.4: [8086:6fbc] type 0 class 0x000880 [ 2.122132] pci 0000:ff:14.5: [8086:6fbd] type 0 class 0x000880 [ 2.122164] pci 0000:ff:14.6: [8086:6fbe] type 0 class 0x000880 [ 2.122195] pci 0000:ff:14.7: [8086:6fbf] type 0 class 0x000880 [ 2.122228] pci 0000:ff:15.0: [8086:6fb4] type 0 class 0x000880 [ 2.122266] pci 0000:ff:15.1: [8086:6fb5] type 0 class 0x000880 [ 2.122304] pci 0000:ff:15.2: [8086:6fb6] type 0 class 0x000880 [ 2.122342] pci 0000:ff:15.3: [8086:6fb7] type 0 class 0x000880 [ 2.122383] pci 0000:ff:16.0: [8086:6f68] type 0 class 0x000880 [ 2.122421] pci 0000:ff:16.6: [8086:6f6e] type 0 class 0x000880 [ 2.122452] pci 0000:ff:16.7: [8086:6f6f] type 0 class 0x000880 [ 2.122482] pci 0000:ff:17.0: [8086:6fd0] type 0 class 0x000880 [ 2.122515] pci 0000:ff:17.4: [8086:6fb8] type 0 class 0x000880 [ 2.122544] pci 0000:ff:17.5: [8086:6fb9] type 0 class 0x000880 [ 2.122573] pci 0000:ff:17.6: [8086:6fba] type 0 class 0x000880 [ 2.122602] pci 0000:ff:17.7: [8086:6fbb] type 0 class 0x000880 [ 2.122636] pci 0000:ff:1e.0: [8086:6f98] type 0 class 0x000880 [ 2.122663] pci 0000:ff:1e.1: [8086:6f99] type 0 class 0x000880 [ 2.122691] pci 0000:ff:1e.2: [8086:6f9a] type 0 class 0x000880 [ 2.122719] pci 0000:ff:1e.3: [8086:6fc0] type 0 class 0x000880 [ 2.122724] pci 0000:ff:1e.3: reg 10: [mem 0x00000010-0x0000001f pref] [ 2.122748] pci 0000:ff:1e.4: [8086:6f9c] type 0 class 0x000880 [ 2.122778] pci 0000:ff:1f.0: [8086:6f88] type 0 class 0x000880 [ 2.122806] pci 0000:ff:1f.2: [8086:6f8a] type 0 class 0x000880 [ 2.122840] ACPI: PCI Interrupt Routing Table [\_SB_.UNC0._PRT] [ 2.125076] pci0000:ff: Requesting ACPI _OSC control (0x1d) [ 2.126447] pci0000:ff: ACPI _OSC control (0x15) granted [ 3.126761] ACPI: PCI Root Bridge [PCI0] (domain 0000 [bus 00-fe]) [ 3.127182] pci_root PNP0A08:00: host bridge window [io 0x0000-0x0cf7] [ 3.127532] pci_root PNP0A08:00: host bridge window [io 0x1000-0xffff] [ 3.127882] pci_root PNP0A08:00: host bridge window [mem 0x000a0000-0x000bffff] [ 3.128504] pci_root PNP0A08:00: host bridge window [mem 0xfedb0000-0xfedb000f] [ 3.129127] pci_root PNP0A08:00: host bridge window [mem 0xfedc0000-0xfedc000f] [ 3.129749] pci_root PNP0A08:00: host bridge window [mem 0x90000000-0xfbffbfff] [ 3.130378] pci 0000:00:00.0: [8086:6f00] type 0 class 0x000600 [ 3.130420] pci 0000:00:01.0: [8086:6f02] type 1 class 0x000604 [ 3.130452] pci 0000:00:01.0: PME# supported from D0 D3hot D3cold [ 3.130454] pci 0000:00:01.0: PME# disabled [ 3.130470] pci 0000:00:02.0: [8086:6f04] type 1 class 0x000604 [ 3.130501] pci 0000:00:02.0: PME# supported from D0 D3hot D3cold [ 3.130504] pci 0000:00:02.0: PME# disabled [ 3.130522] pci 0000:00:02.2: [8086:6f06] type 1 class 0x000604 [ 3.130553] pci 0000:00:02.2: PME# supported from D0 D3hot D3cold [ 3.130555] pci 0000:00:02.2: PME# disabled [ 3.130573] pci 0000:00:03.0: [8086:6f08] type 1 class 0x000604 [ 3.130604] pci 0000:00:03.0: PME# supported from D0 D3hot D3cold [ 3.130607] pci 0000:00:03.0: PME# disabled [ 3.130623] pci 0000:00:03.2: [8086:6f0a] type 1 class 0x000604 [ 3.130654] pci 0000:00:03.2: PME# supported from D0 D3hot D3cold [ 3.130656] pci 0000:00:03.2: PME# disabled [ 3.130673] pci 0000:00:04.0: [8086:6f20] type 0 class 0x000880 [ 3.130684] pci 0000:00:04.0: reg 10: [mem 0xe8b2c000-0xe8b2ffff 64bit] [ 3.130726] pci 0000:00:04.1: [8086:6f21] type 0 class 0x000880 [ 3.130734] pci 0000:00:04.1: reg 10: [mem 0xe8b28000-0xe8b2bfff 64bit] [ 3.130776] pci 0000:00:04.2: [8086:6f22] type 0 class 0x000880 [ 3.130785] pci 0000:00:04.2: reg 10: [mem 0xe8b24000-0xe8b27fff 64bit] [ 3.130826] pci 0000:00:04.3: [8086:6f23] type 0 class 0x000880 [ 3.130835] pci 0000:00:04.3: reg 10: [mem 0xe8b20000-0xe8b23fff 64bit] [ 3.130877] pci 0000:00:04.4: [8086:6f24] type 0 class 0x000880 [ 3.130885] pci 0000:00:04.4: reg 10: [mem 0xe8b1c000-0xe8b1ffff 64bit] [ 3.130928] pci 0000:00:04.5: [8086:6f25] type 0 class 0x000880 [ 3.130936] pci 0000:00:04.5: reg 10: [mem 0xe8b18000-0xe8b1bfff 64bit] [ 3.130978] pci 0000:00:04.6: [8086:6f26] type 0 class 0x000880 [ 3.130987] pci 0000:00:04.6: reg 10: [mem 0xe8b14000-0xe8b17fff 64bit] [ 3.131028] pci 0000:00:04.7: [8086:6f27] type 0 class 0x000880 [ 3.131037] pci 0000:00:04.7: reg 10: [mem 0xe8b10000-0xe8b13fff 64bit] [ 3.131077] pci 0000:00:05.0: [8086:6f28] type 0 class 0x000880 [ 3.131119] pci 0000:00:05.1: [8086:6f29] type 0 class 0x000880 [ 3.131164] pci 0000:00:05.2: [8086:6f2a] type 0 class 0x000880 [ 3.131206] pci 0000:00:05.4: [8086:6f2c] type 0 class 0x000800 [ 3.131212] pci 0000:00:05.4: reg 10: [mem 0xe8b39000-0xe8b39fff] [ 3.131265] pci 0000:00:11.0: [8086:8d7c] type 0 class 0x00ff00 [ 3.131365] pci 0000:00:11.4: [8086:8d62] type 0 class 0x000106 [ 3.131383] pci 0000:00:11.4: reg 10: [io 0xf110-0xf117] [ 3.131391] pci 0000:00:11.4: reg 14: [io 0xf100-0xf103] [ 3.131399] pci 0000:00:11.4: reg 18: [io 0xf0f0-0xf0f7] [ 3.131407] pci 0000:00:11.4: reg 1c: [io 0xf0e0-0xf0e3] [ 3.131415] pci 0000:00:11.4: reg 20: [io 0xf020-0xf03f] [ 3.131423] pci 0000:00:11.4: reg 24: [mem 0xe8b38000-0xe8b387ff] [ 3.131454] pci 0000:00:11.4: PME# supported from D3hot [ 3.131457] pci 0000:00:11.4: PME# disabled [ 3.131483] pci 0000:00:14.0: [8086:8d31] type 0 class 0x000c03 [ 3.131501] pci 0000:00:14.0: reg 10: [mem 0xe8b00000-0xe8b0ffff 64bit] [ 3.131549] pci 0000:00:14.0: PME# supported from D3hot D3cold [ 3.131552] pci 0000:00:14.0: PME# disabled [ 3.131569] pci 0000:00:16.0: [8086:8d3a] type 0 class 0x000780 [ 3.131587] pci 0000:00:16.0: reg 10: [mem 0xe8b37000-0xe8b3700f 64bit] [ 3.131636] pci 0000:00:16.0: PME# supported from D0 D3hot D3cold [ 3.131639] pci 0000:00:16.0: PME# disabled [ 3.131655] pci 0000:00:16.1: [8086:8d3b] type 0 class 0x000780 [ 3.131673] pci 0000:00:16.1: reg 10: [mem 0xe8b36000-0xe8b3600f 64bit] [ 3.131723] pci 0000:00:16.1: PME# supported from D0 D3hot D3cold [ 3.131726] pci 0000:00:16.1: PME# disabled [ 3.131755] pci 0000:00:1a.0: [8086:8d2d] type 0 class 0x000c03 [ 3.131775] pci 0000:00:1a.0: reg 10: [mem 0xe8b34000-0xe8b343ff] [ 3.131844] pci 0000:00:1a.0: PME# supported from D0 D3hot D3cold [ 3.131848] pci 0000:00:1a.0: PME# disabled [ 3.131866] pci 0000:00:1c.0: [8086:8d10] type 1 class 0x000604 [ 3.131916] pci 0000:00:1c.0: PME# supported from D0 D3hot D3cold [ 3.131919] pci 0000:00:1c.0: PME# disabled [ 3.131938] pci 0000:00:1c.2: [8086:8d14] type 1 class 0x000604 [ 3.131988] pci 0000:00:1c.2: PME# supported from D0 D3hot D3cold [ 3.131991] pci 0000:00:1c.2: PME# disabled [ 3.132010] pci 0000:00:1c.4: [8086:8d18] type 1 class 0x000604 [ 3.132061] pci 0000:00:1c.4: PME# supported from D0 D3hot D3cold [ 3.132063] pci 0000:00:1c.4: PME# disabled [ 3.132092] pci 0000:00:1d.0: [8086:8d26] type 0 class 0x000c03 [ 3.132112] pci 0000:00:1d.0: reg 10: [mem 0xe8b33000-0xe8b333ff] [ 3.132181] pci 0000:00:1d.0: PME# supported from D0 D3hot D3cold [ 3.132185] pci 0000:00:1d.0: PME# disabled [ 3.132206] pci 0000:00:1f.0: [8086:8d44] type 0 class 0x000601 [ 3.132312] pci 0000:00:1f.2: [8086:8d02] type 0 class 0x000106 [ 3.132327] pci 0000:00:1f.2: reg 10: [io 0xf070-0xf077] [ 3.132334] pci 0000:00:1f.2: reg 14: [io 0xf060-0xf063] [ 3.132341] pci 0000:00:1f.2: reg 18: [io 0xf050-0xf057] [ 3.132348] pci 0000:00:1f.2: reg 1c: [io 0xf040-0xf043] [ 3.132354] pci 0000:00:1f.2: reg 20: [io 0xf000-0xf01f] [ 3.132361] pci 0000:00:1f.2: reg 24: [mem 0xe8b32000-0xe8b327ff] [ 3.132388] pci 0000:00:1f.2: PME# supported from D3hot [ 3.132390] pci 0000:00:1f.2: PME# disabled [ 3.132403] pci 0000:00:1f.3: [8086:8d22] type 0 class 0x000c05 [ 3.132416] pci 0000:00:1f.3: reg 10: [mem 0xe8b31000-0xe8b310ff 64bit] [ 3.132436] pci 0000:00:1f.3: reg 20: [io 0x0580-0x059f] [ 3.132483] pci 0000:00:01.0: PCI bridge to [bus 01-01] [ 3.132832] pci 0000:00:01.0: bridge window [io 0xf000-0x0000] (disabled) [ 3.132835] pci 0000:00:01.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 3.132839] pci 0000:00:01.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 3.132864] pci 0000:00:02.0: PCI bridge to [bus 02-02] [ 3.133211] pci 0000:00:02.0: bridge window [io 0xf000-0x0000] (disabled) [ 3.133214] pci 0000:00:02.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 3.133217] pci 0000:00:02.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 3.133254] pci 0000:03:00.0: [111d:8091] type 1 class 0x000604 [ 3.133334] pci 0000:03:00.0: PME# supported from D0 D3hot D3cold [ 3.133337] pci 0000:03:00.0: PME# disabled [ 3.133373] pci 0000:03:00.1: [111d:8091] type 0 class 0x000680 [ 3.133391] pci 0000:03:00.1: reg 10: [mem 0xf8801000-0xf8801fff] [ 3.133425] pci 0000:03:00.1: reg 18: [mem 0xd0000000-0xdfffffff 64bit pref] [ 3.133438] pci 0000:03:00.1: reg 20: [mem 0xf4000000-0xf7ffffff] [ 3.133452] pci 0000:03:00.1: reg 24: [mem 0xf8000000-0xf87fffff] [ 3.133527] pci 0000:03:00.2: [111d:8091] type 0 class 0x000880 [ 3.133541] pci 0000:03:00.2: reg 10: [mem 0xf8800000-0xf8800fff] [ 3.133661] pci 0000:00:02.2: PCI bridge to [bus 03-04] [ 3.134009] pci 0000:00:02.2: bridge window [io 0xf000-0x0000] (disabled) [ 3.134011] pci 0000:00:02.2: bridge window [mem 0xf4000000-0xf88fffff] [ 3.134015] pci 0000:00:02.2: bridge window [mem 0xd0000000-0xdfffffff 64bit pref] [ 3.134090] pci 0000:03:00.0: PCI bridge to [bus 04-04] [ 3.134442] pci 0000:03:00.0: bridge window [io 0xfff000-0x0000] (disabled) [ 3.134446] pci 0000:03:00.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 3.134454] pci 0000:03:00.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 3.134498] pci 0000:05:00.0: [10b5:8608] type 1 class 0x000604 [ 3.134508] pci 0000:05:00.0: reg 10: [mem 0xf0a00000-0xf0a1ffff] [ 3.134552] pci 0000:05:00.0: PME# supported from D0 D3hot D3cold [ 3.134555] pci 0000:05:00.0: PME# disabled [ 3.134578] pci 0000:00:03.0: PCI bridge to [bus 05-0d] [ 3.134926] pci 0000:00:03.0: bridge window [io 0xf000-0x0000] (disabled) [ 3.134928] pci 0000:00:03.0: bridge window [mem 0xec000000-0xf0afffff] [ 3.134932] pci 0000:00:03.0: bridge window [mem 0xc0000000-0xcfffffff 64bit pref] [ 3.134985] pci 0000:06:01.0: [10b5:8608] type 1 class 0x000604 [ 3.135038] pci 0000:06:01.0: PME# supported from D0 D3hot D3cold [ 3.135041] pci 0000:06:01.0: PME# disabled [ 3.135082] pci 0000:05:00.0: PCI bridge to [bus 06-0d] [ 3.135431] pci 0000:05:00.0: bridge window [io 0xfff000-0x0000] (disabled) [ 3.135434] pci 0000:05:00.0: bridge window [mem 0xec000000-0xf09fffff] [ 3.135439] pci 0000:05:00.0: bridge window [mem 0xc0000000-0xcfffffff 64bit pref] [ 3.135970] pci 0000:07:00.0: [10b5:8606] type 1 class 0x000604 [ 3.136415] pci 0000:07:00.0: reg 10: [mem 0xf0900000-0xf091ffff] [ 3.138508] pci 0000:07:00.0: PME# supported from D0 D3hot D3cold [ 3.138598] pci 0000:07:00.0: PME# disabled [ 3.139712] pci 0000:06:01.0: PCI bridge to [bus 07-0d] [ 3.140060] pci 0000:06:01.0: bridge window [io 0xfff000-0x0000] (disabled) [ 3.140064] pci 0000:06:01.0: bridge window [mem 0xec000000-0xf09fffff] [ 3.140069] pci 0000:06:01.0: bridge window [mem 0xc0000000-0xcfffffff 64bit pref] [ 3.142490] pci 0000:08:01.0: [10b5:8606] type 1 class 0x000604 [ 3.145072] pci 0000:08:01.0: PME# supported from D0 D3hot D3cold [ 3.145162] pci 0000:08:01.0: PME# disabled [ 3.146452] pci 0000:08:05.0: [10b5:8606] type 1 class 0x000604 [ 3.149034] pci 0000:08:05.0: PME# supported from D0 D3hot D3cold [ 3.149124] pci 0000:08:05.0: PME# disabled [ 3.150343] pci 0000:08:07.0: [10b5:8606] type 1 class 0x000604 [ 3.152924] pci 0000:08:07.0: PME# supported from D0 D3hot D3cold [ 3.153014] pci 0000:08:07.0: PME# disabled [ 3.154216] pci 0000:08:09.0: [10b5:8606] type 1 class 0x000604 [ 3.156797] pci 0000:08:09.0: PME# supported from D0 D3hot D3cold [ 3.156887] pci 0000:08:09.0: PME# disabled [ 3.158531] pci 0000:07:00.0: PCI bridge to [bus 08-0d] [ 3.159054] pci 0000:07:00.0: bridge window [io 0xfff000-0x0000] (disabled) [ 3.159144] pci 0000:07:00.0: bridge window [mem 0xec000000-0xf08fffff] [ 3.159323] pci 0000:07:00.0: bridge window [mem 0xc0000000-0xcfffffff 64bit pref] [ 3.161255] pci 0000:08:01.0: PCI bridge to [bus 09-09] [ 3.161776] pci 0000:08:01.0: bridge window [io 0xfff000-0x0000] (disabled) [ 3.161866] pci 0000:08:01.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 3.162046] pci 0000:08:01.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 3.164005] pci 0000:08:05.0: PCI bridge to [bus 0a-0a] [ 3.164525] pci 0000:08:05.0: bridge window [io 0xfff000-0x0000] (disabled) [ 3.164616] pci 0000:08:05.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 3.164796] pci 0000:08:05.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 3.166755] pci 0000:08:07.0: PCI bridge to [bus 0b-0b] [ 3.167276] pci 0000:08:07.0: bridge window [io 0xfff000-0x0000] (disabled) [ 3.167366] pci 0000:08:07.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 3.167545] pci 0000:08:07.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 3.169781] pci 0000:0c:00.0: [111d:8091] type 1 class 0x000604 [ 3.172085] pci 0000:0c:00.0: PME# supported from D0 D3hot D3cold [ 3.172177] pci 0000:0c:00.0: PME# disabled [ 3.173227] pci 0000:0c:00.1: [111d:8091] type 0 class 0x000680 [ 3.173687] pci 0000:0c:00.1: reg 10: [mem 0xf0801000-0xf0801fff] [ 3.174515] pci 0000:0c:00.1: reg 18: [mem 0xc0000000-0xcfffffff 64bit pref] [ 3.174838] pci 0000:0c:00.1: reg 20: [mem 0xec000000-0xefffffff] [ 3.175161] pci 0000:0c:00.1: reg 24: [mem 0xf0000000-0xf07fffff] [ 3.177356] pci 0000:0c:00.2: [111d:8091] type 0 class 0x000880 [ 3.177812] pci 0000:0c:00.2: reg 10: [mem 0xf0800000-0xf0800fff] [ 3.181656] pci 0000:08:09.0: PCI bridge to [bus 0c-0d] [ 3.182175] pci 0000:08:09.0: bridge window [io 0xfff000-0x0000] (disabled) [ 3.182265] pci 0000:08:09.0: bridge window [mem 0xec000000-0xf08fffff] [ 3.182444] pci 0000:08:09.0: bridge window [mem 0xc0000000-0xcfffffff 64bit pref] [ 3.185344] pci 0000:0c:00.0: PCI bridge to [bus 0d-0d] [ 3.185868] pci 0000:0c:00.0: bridge window [io 0xfff000-0x0000] (disabled) [ 3.185960] pci 0000:0c:00.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 3.186144] pci 0000:0c:00.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 3.187396] pci 0000:0e:00.0: [10b5:8608] type 1 class 0x000604 [ 3.187406] pci 0000:0e:00.0: reg 10: [mem 0xe8a00000-0xe8a1ffff] [ 3.187449] pci 0000:0e:00.0: PME# supported from D0 D3hot D3cold [ 3.187452] pci 0000:0e:00.0: PME# disabled [ 3.187474] pci 0000:00:03.2: PCI bridge to [bus 0e-16] [ 3.187818] pci 0000:00:03.2: bridge window [io 0xf000-0x0000] (disabled) [ 3.187820] pci 0000:00:03.2: bridge window [mem 0xe4000000-0xe8afffff] [ 3.187824] pci 0000:00:03.2: bridge window [mem 0xb0000000-0xbfffffff 64bit pref] [ 3.187874] pci 0000:0f:01.0: [10b5:8608] type 1 class 0x000604 [ 3.187927] pci 0000:0f:01.0: PME# supported from D0 D3hot D3cold [ 3.187930] pci 0000:0f:01.0: PME# disabled [ 3.187970] pci 0000:0e:00.0: PCI bridge to [bus 0f-16] [ 3.188315] pci 0000:0e:00.0: bridge window [io 0xfff000-0x0000] (disabled) [ 3.188318] pci 0000:0e:00.0: bridge window [mem 0xe4000000-0xe89fffff] [ 3.188323] pci 0000:0e:00.0: bridge window [mem 0xb0000000-0xbfffffff 64bit pref] [ 3.188857] pci 0000:10:00.0: [10b5:8606] type 1 class 0x000604 [ 3.189306] pci 0000:10:00.0: reg 10: [mem 0xe8900000-0xe891ffff] [ 3.191431] pci 0000:10:00.0: PME# supported from D0 D3hot D3cold [ 3.191522] pci 0000:10:00.0: PME# disabled [ 3.192645] pci 0000:0f:01.0: PCI bridge to [bus 10-16] [ 3.192989] pci 0000:0f:01.0: bridge window [io 0xfff000-0x0000] (disabled) [ 3.192993] pci 0000:0f:01.0: bridge window [mem 0xe4000000-0xe89fffff] [ 3.192998] pci 0000:0f:01.0: bridge window [mem 0xb0000000-0xbfffffff 64bit pref] [ 3.195421] pci 0000:11:01.0: [10b5:8606] type 1 class 0x000604 [ 3.198024] pci 0000:11:01.0: PME# supported from D0 D3hot D3cold [ 3.198114] pci 0000:11:01.0: PME# disabled [ 3.199416] pci 0000:11:05.0: [10b5:8606] type 1 class 0x000604 [ 3.202033] pci 0000:11:05.0: PME# supported from D0 D3hot D3cold [ 3.202124] pci 0000:11:05.0: PME# disabled [ 3.203336] pci 0000:11:07.0: [10b5:8606] type 1 class 0x000604 [ 3.205937] pci 0000:11:07.0: PME# supported from D0 D3hot D3cold [ 3.206028] pci 0000:11:07.0: PME# disabled [ 3.207240] pci 0000:11:09.0: [10b5:8606] type 1 class 0x000604 [ 3.209842] pci 0000:11:09.0: PME# supported from D0 D3hot D3cold [ 3.209932] pci 0000:11:09.0: PME# disabled [ 3.211607] pci 0000:10:00.0: PCI bridge to [bus 11-16] [ 3.212127] pci 0000:10:00.0: bridge window [io 0xfff000-0x0000] (disabled) [ 3.212218] pci 0000:10:00.0: bridge window [mem 0xe4000000-0xe88fffff] [ 3.212399] pci 0000:10:00.0: bridge window [mem 0xb0000000-0xbfffffff 64bit pref] [ 3.214329] pci 0000:11:01.0: PCI bridge to [bus 12-12] [ 3.214849] pci 0000:11:01.0: bridge window [io 0xfff000-0x0000] (disabled) [ 3.214940] pci 0000:11:01.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 3.215121] pci 0000:11:01.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 3.217096] pci 0000:11:05.0: PCI bridge to [bus 13-13] [ 3.217617] pci 0000:11:05.0: bridge window [io 0xfff000-0x0000] (disabled) [ 3.217708] pci 0000:11:05.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 3.217889] pci 0000:11:05.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 3.219864] pci 0000:11:07.0: PCI bridge to [bus 14-14] [ 3.220399] pci 0000:11:07.0: bridge window [io 0xfff000-0x0000] (disabled) [ 3.220490] pci 0000:11:07.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 3.220672] pci 0000:11:07.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 3.222926] pci 0000:15:00.0: [111d:8091] type 1 class 0x000604 [ 3.225230] pci 0000:15:00.0: PME# supported from D0 D3hot D3cold [ 3.225323] pci 0000:15:00.0: PME# disabled [ 3.226381] pci 0000:15:00.1: [111d:8091] type 0 class 0x000680 [ 3.226845] pci 0000:15:00.1: reg 10: [mem 0xe8801000-0xe8801fff] [ 3.227680] pci 0000:15:00.1: reg 18: [mem 0xb0000000-0xbfffffff 64bit pref] [ 3.228005] pci 0000:15:00.1: reg 20: [mem 0xe4000000-0xe7ffffff] [ 3.228330] pci 0000:15:00.1: reg 24: [mem 0xe8000000-0xe87fffff] [ 3.230558] pci 0000:15:00.2: [111d:8091] type 0 class 0x000880 [ 3.231016] pci 0000:15:00.2: reg 10: [mem 0xe8800000-0xe8800fff] [ 3.234873] pci 0000:11:09.0: PCI bridge to [bus 15-16] [ 3.235392] pci 0000:11:09.0: bridge window [io 0xfff000-0x0000] (disabled) [ 3.235483] pci 0000:11:09.0: bridge window [mem 0xe4000000-0xe88fffff] [ 3.235664] pci 0000:11:09.0: bridge window [mem 0xb0000000-0xbfffffff 64bit pref] [ 3.238588] pci 0000:15:00.0: PCI bridge to [bus 16-16] [ 3.239109] pci 0000:15:00.0: bridge window [io 0xfff000-0x0000] (disabled) [ 3.239202] pci 0000:15:00.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 3.239387] pci 0000:15:00.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 3.240671] pci 0000:00:1c.0: PCI bridge to [bus 17-17] [ 3.241012] pci 0000:00:1c.0: bridge window [io 0xf000-0x0000] (disabled) [ 3.241015] pci 0000:00:1c.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 3.241019] pci 0000:00:1c.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 3.241072] pci 0000:18:00.0: [1a03:1150] type 1 class 0x000604 [ 3.241164] pci 0000:18:00.0: supports D1 D2 [ 3.241166] pci 0000:18:00.0: PME# supported from D0 D1 D2 D3hot D3cold [ 3.241170] pci 0000:18:00.0: PME# disabled [ 3.241199] pci 0000:00:1c.2: PCI bridge to [bus 18-19] [ 3.241539] pci 0000:00:1c.2: bridge window [io 0xe000-0xefff] [ 3.241542] pci 0000:00:1c.2: bridge window [mem 0xf9000000-0xfa0fffff] [ 3.241547] pci 0000:00:1c.2: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 3.241632] pci 0000:19:00.0: [1a03:2000] type 0 class 0x000300 [ 3.241659] pci 0000:19:00.0: reg 10: [mem 0xf9000000-0xf9ffffff] [ 3.241673] pci 0000:19:00.0: reg 14: [mem 0xfa000000-0xfa01ffff] [ 3.241686] pci 0000:19:00.0: reg 18: [io 0xe000-0xe07f] [ 3.241767] pci 0000:19:00.0: supports D1 D2 [ 3.241769] pci 0000:19:00.0: PME# supported from D0 D1 D2 D3hot D3cold [ 3.241773] pci 0000:19:00.0: PME# disabled [ 3.241840] pci 0000:18:00.0: PCI bridge to [bus 19-19] [ 3.242184] pci 0000:18:00.0: bridge window [io 0xe000-0xefff] [ 3.242189] pci 0000:18:00.0: bridge window [mem 0xf9000000-0xfa0fffff] [ 3.242196] pci 0000:18:00.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 3.242257] pci 0000:1a:00.0: [8086:1521] type 0 class 0x000200 [ 3.242272] pci 0000:1a:00.0: reg 10: [mem 0xfa220000-0xfa23ffff] [ 3.242291] pci 0000:1a:00.0: reg 18: [io 0xd020-0xd03f] [ 3.242302] pci 0000:1a:00.0: reg 1c: [mem 0xfa244000-0xfa247fff] [ 3.242365] pci 0000:1a:00.0: PME# supported from D0 D3hot D3cold [ 3.242369] pci 0000:1a:00.0: PME# disabled [ 3.242415] pci 0000:1a:00.0: reg 184: [mem 0x00000000-0x00003fff 64bit pref] [ 3.242438] pci 0000:1a:00.0: reg 190: [mem 0x00000000-0x00003fff 64bit pref] [ 3.242469] pci 0000:1a:00.1: [8086:1521] type 0 class 0x000200 [ 3.242483] pci 0000:1a:00.1: reg 10: [mem 0xfa200000-0xfa21ffff] [ 3.242504] pci 0000:1a:00.1: reg 18: [io 0xd000-0xd01f] [ 3.242515] pci 0000:1a:00.1: reg 1c: [mem 0xfa240000-0xfa243fff] [ 3.242578] pci 0000:1a:00.1: PME# supported from D0 D3hot D3cold [ 3.242582] pci 0000:1a:00.1: PME# disabled [ 3.242622] pci 0000:1a:00.1: reg 184: [mem 0x00000000-0x00003fff 64bit pref] [ 3.242645] pci 0000:1a:00.1: reg 190: [mem 0x00000000-0x00003fff 64bit pref] [ 3.242674] pci 0000:00:1c.4: PCI bridge to [bus 1a-1a] [ 3.243014] pci 0000:00:1c.4: bridge window [io 0xd000-0xdfff] [ 3.243017] pci 0000:00:1c.4: bridge window [mem 0xfa200000-0xfa2fffff] [ 3.243022] pci 0000:00:1c.4: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 3.243044] pci_bus 0000:00: on NUMA node 0 (pxm 0) [ 3.243046] ACPI: PCI Interrupt Routing Table [\_SB_.PCI0._PRT] [ 3.243161] ACPI: PCI Interrupt Routing Table [\_SB_.PCI0.RP03._PRT] [ 3.243180] ACPI: PCI Interrupt Routing Table [\_SB_.PCI0.RP03.BR7A._PRT] [ 3.243203] ACPI: PCI Interrupt Routing Table [\_SB_.PCI0.RP05._PRT] [ 3.243244] ACPI: PCI Interrupt Routing Table [\_SB_.PCI0.BR1A._PRT] [ 3.243281] ACPI: PCI Interrupt Routing Table [\_SB_.PCI0.BR2A._PRT] [ 3.243321] ACPI: PCI Interrupt Routing Table [\_SB_.PCI0.BR2C._PRT] [ 3.243370] ACPI: PCI Interrupt Routing Table [\_SB_.PCI0.BR3A._PRT] [ 3.243410] ACPI: PCI Interrupt Routing Table [\_SB_.PCI0.BR3C._PRT] [ 3.243632] pci0000:00: Requesting ACPI _OSC control (0x1d) [ 3.244422] pci0000:00: ACPI _OSC control (0x15) granted [ 3.256303] ACPI: PCI Interrupt Link [LNKA] (IRQs 3 4 5 6 7 10 *11 12 14 15) [ 3.257402] ACPI: PCI Interrupt Link [LNKB] (IRQs 3 4 5 6 7 *10 11 12 14 15) [ 3.258501] ACPI: PCI Interrupt Link [LNKC] (IRQs 3 4 *5 6 10 11 12 14 15) [ 3.259538] ACPI: PCI Interrupt Link [LNKD] (IRQs 3 4 5 6 10 *11 12 14 15) [ 3.260589] ACPI: PCI Interrupt Link [LNKE] (IRQs 3 4 5 6 7 10 11 12 14 15) *0, disabled. [ 3.262073] ACPI: PCI Interrupt Link [LNKF] (IRQs 3 4 5 6 7 10 11 12 14 15) *0, disabled. [ 3.263558] ACPI: PCI Interrupt Link [LNKG] (IRQs 3 4 5 6 7 10 11 12 14 15) *0, disabled. [ 3.265044] ACPI: PCI Interrupt Link [LNKH] (IRQs 3 4 5 6 7 10 11 12 14 15) *0, disabled. [ 3.266629] vgaarb: device added: PCI:0000:19:00.0,decodes=io+mem,owns=io+mem,locks=none [ 3.267238] vgaarb: loaded [ 3.267572] vgaarb: bridge control possible 0000:19:00.0 [ 3.268005] SCSI subsystem initialized [ 3.268410] libata version 3.00 loaded. [ 3.268529] usbcore: registered new interface driver usbfs [ 3.268890] usbcore: registered new interface driver hub [ 3.269258] usbcore: registered new device driver usb [ 3.269755] Advanced Linux Sound Architecture Driver Version 1.0.24. [ 3.270111] PCI: Using ACPI for IRQ routing [ 3.275696] PCI: pci_cache_line_size set to 64 bytes [ 3.276555] pci 0000:ff:1e.3: no compatible bridge window for [mem 0x00000010-0x0000001f pref] [ 3.277943] reserve RAM buffer: 000000000009b000 - 000000000009ffff [ 3.277945] reserve RAM buffer: 0000000078f58000 - 000000007bffffff [ 3.278116] cfg80211: Calling CRDA to update world regulatory domain [ 3.278628] hpet0: at MMIO 0xfed00000, IRQs 2, 8, 0, 0, 0, 0, 0, 0 [ 3.279516] hpet0: 8 comparators, 64-bit 14.318180 MHz counter [ 3.281901] Switching to clocksource hpet [ 3.282285] pnp: PnP ACPI init [ 3.282373] Switched to NOHz mode on CPU #3 [ 3.282384] Switched to NOHz mode on CPU #8 [ 3.282395] Switched to NOHz mode on CPU #2 [ 3.282404] Switched to NOHz mode on CPU #7 [ 3.282421] Switched to NOHz mode on CPU #9 [ 3.282434] Switched to NOHz mode on CPU #6 [ 3.282441] Switched to NOHz mode on CPU #1 [ 3.282459] Switched to NOHz mode on CPU #5 [ 3.282466] Switched to NOHz mode on CPU #4 [ 3.285665] Switched to NOHz mode on CPU #0 [ 3.286012] ACPI: bus type pnp registered [ 3.286421] pnp 00:00: [bus ff] [ 3.286506] pnp 00:00: Plug and Play ACPI device, IDs PNP0a03 (active) [ 3.286641] pnp 00:01: [bus 00-fe] [ 3.286642] pnp 00:01: [io 0x0cf8-0x0cff] [ 3.286644] pnp 00:01: [io 0x0000-0x0cf7 window] [ 3.286645] pnp 00:01: [io 0x1000-0xffff window] [ 3.286647] pnp 00:01: [mem 0x000a0000-0x000bffff window] [ 3.286648] pnp 00:01: [mem 0xfedb0000-0xfedb000f window] [ 3.286650] pnp 00:01: [mem 0xfedc0000-0xfedc000f window] [ 3.286651] pnp 00:01: [mem 0x90000000-0xfbffbfff window] [ 3.286653] pnp 00:01: [mem 0x00000000 window] [ 3.286740] pnp 00:01: Plug and Play ACPI device, IDs PNP0a08 PNP0a03 (active) [ 3.286745] pnp 00:02: [mem 0xfec00000-0xfecfffff] [ 3.286779] pnp 00:02: Plug and Play ACPI device, IDs PNP0003 (active) [ 3.286793] pnp 00:03: [io 0x0000-0x000f] [ 3.286794] pnp 00:03: [io 0x0081-0x0083] [ 3.286795] pnp 00:03: [io 0x0087] [ 3.286796] pnp 00:03: [io 0x0089-0x008b] [ 3.286797] pnp 00:03: [io 0x008f] [ 3.286799] pnp 00:03: [io 0x00c0-0x00df] [ 3.286800] pnp 00:03: [dma 4] [ 3.286834] pnp 00:03: Plug and Play ACPI device, IDs PNP0200 (active) [ 3.286839] pnp 00:04: [io 0x0070-0x0071] [ 3.286840] pnp 00:04: [io 0x0074-0x0077] [ 3.286846] pnp 00:04: [irq 8] [ 3.286881] pnp 00:04: Plug and Play ACPI device, IDs PNP0b00 (active) [ 3.286886] pnp 00:05: [io 0x00f0] [ 3.286890] pnp 00:05: [irq 13] [ 3.286922] pnp 00:05: Plug and Play ACPI device, IDs PNP0c04 (active) [ 3.286928] pnp 00:06: [io 0x0061] [ 3.286962] pnp 00:06: Plug and Play ACPI device, IDs PNP0800 (active) [ 3.286989] pnp 00:07: [mem 0xfed00000-0xfed003ff] [ 3.287023] pnp 00:07: Plug and Play ACPI device, IDs PNP0103 (active) [ 3.287030] pnp 00:08: [io 0x0500-0x057f] [ 3.287031] pnp 00:08: [io 0x0400-0x047f] [ 3.287032] pnp 00:08: [io 0x0092] [ 3.287033] pnp 00:08: [io 0x0010-0x001f] [ 3.287036] pnp 00:08: [io 0x0072-0x0073] [ 3.287037] pnp 00:08: [io 0x0080] [ 3.287038] pnp 00:08: [io 0x0084-0x0086] [ 3.287039] pnp 00:08: [io 0x0088] [ 3.287041] pnp 00:08: [io 0x008c-0x008e] [ 3.287042] pnp 00:08: [io 0x0090-0x009f] [ 3.287043] pnp 00:08: [io 0x0580-0x059f] [ 3.287044] pnp 00:08: [io 0x0600-0x061f] [ 3.287045] pnp 00:08: [io 0x0880-0x0883] [ 3.287046] pnp 00:08: [io 0x0800-0x081f] [ 3.287048] pnp 00:08: [mem 0xfed1c000-0xfed3ffff] [ 3.287049] pnp 00:08: [mem 0xfed45000-0xfed8bfff] [ 3.287050] pnp 00:08: [mem 0xff000000-0xffffffff] [ 3.287051] pnp 00:08: [mem 0xfee00000-0xfeefffff] [ 3.287053] pnp 00:08: [mem 0xfed12000-0xfed1200f] [ 3.287054] pnp 00:08: [mem 0xfed12010-0xfed1201f] [ 3.287055] pnp 00:08: [mem 0xfed1b000-0xfed1bfff] [ 3.287158] system 00:08: [io 0x0500-0x057f] has been reserved [ 3.287497] system 00:08: [io 0x0400-0x047f] has been reserved [ 3.287845] system 00:08: [io 0x0580-0x059f] has been reserved [ 3.288184] system 00:08: [io 0x0600-0x061f] has been reserved [ 3.288523] system 00:08: [io 0x0880-0x0883] has been reserved [ 3.288867] system 00:08: [io 0x0800-0x081f] has been reserved [ 3.289207] system 00:08: [mem 0xfed1c000-0xfed3ffff] has been reserved [ 3.289548] system 00:08: [mem 0xfed45000-0xfed8bfff] has been reserved [ 3.289894] system 00:08: [mem 0xff000000-0xffffffff] has been reserved [ 3.290234] system 00:08: [mem 0xfee00000-0xfeefffff] has been reserved [ 3.290575] system 00:08: [mem 0xfed12000-0xfed1200f] has been reserved [ 3.290921] system 00:08: [mem 0xfed12010-0xfed1201f] has been reserved [ 3.291262] system 00:08: [mem 0xfed1b000-0xfed1bfff] has been reserved [ 3.291603] system 00:08: Plug and Play ACPI device, IDs PNP0c02 (active) [ 3.291729] pnp 00:09: [io 0x0000-0xffffffffffffffff disabled] [ 3.291731] pnp 00:09: [io 0x0a00-0x0a0f] [ 3.291732] pnp 00:09: [io 0x0a10-0x0a1f] [ 3.291733] pnp 00:09: [io 0x0a20-0x0a2f] [ 3.291734] pnp 00:09: [io 0x0a30-0x0a3f] [ 3.291735] pnp 00:09: [io 0x0a40-0x0a4f] [ 3.291810] system 00:09: [io 0x0a00-0x0a0f] has been reserved [ 3.292149] system 00:09: [io 0x0a10-0x0a1f] has been reserved [ 3.292489] system 00:09: [io 0x0a20-0x0a2f] has been reserved [ 3.292834] system 00:09: [io 0x0a30-0x0a3f] has been reserved [ 3.293173] system 00:09: [io 0x0a40-0x0a4f] has been reserved [ 3.293513] system 00:09: Plug and Play ACPI device, IDs PNP0c02 (active) [ 3.293681] pnp 00:0a: [io 0x03f8-0x03ff] [ 3.293685] pnp 00:0a: [irq 4] [ 3.293687] pnp 00:0a: [dma 0 disabled] [ 3.293744] pnp 00:0a: Plug and Play ACPI device, IDs PNP0501 (active) [ 3.293898] pnp 00:0b: [io 0x02f8-0x02ff] [ 3.293901] pnp 00:0b: [irq 3] [ 3.293902] pnp 00:0b: [dma 0 disabled] [ 3.293957] pnp 00:0b: Plug and Play ACPI device, IDs PNP0501 (active) [ 3.294019] pnp 00:0c: [io 0x0ca2] [ 3.294021] pnp 00:0c: [io 0x0ca3] [ 3.294055] pnp 00:0c: Plug and Play ACPI device, IDs IPI0001 (active) [ 3.294476] pnp: PnP ACPI: found 13 devices [ 3.294818] ACPI: ACPI bus type pnp unregistered [ 3.302057] PCI: max bus depth: 6 pci_try_num: 7 [ 3.305388] pci 0000:1a:00.0: reg 184: [mem 0x00000000-0x00003fff 64bit pref] [ 3.305402] pci 0000:1a:00.0: reg 190: [mem 0x00000000-0x00003fff 64bit pref] [ 3.305417] pci 0000:1a:00.1: reg 184: [mem 0x00000000-0x00003fff 64bit pref] [ 3.305431] pci 0000:1a:00.1: reg 190: [mem 0x00000000-0x00003fff 64bit pref] [ 3.305438] pci 0000:ff:12.0: BAR 2: can't assign mem (size 0x40) [ 3.305783] pci 0000:ff:12.0: BAR 4: can't assign mem (size 0x40) [ 3.306122] pci 0000:ff:12.0: BAR 1: can't assign mem (size 0x10) [ 3.306463] pci 0000:ff:12.0: BAR 3: can't assign mem (size 0x10) [ 3.306807] pci 0000:ff:12.0: BAR 5: can't assign mem (size 0x10) [ 3.307147] pci 0000:ff:1e.3: BAR 0: trying firmware assignment [mem 0x00000010-0x0000001f pref] [ 3.307762] pci 0000:ff:1e.3: BAR 0: [mem 0x00000010-0x0000001f pref] conflicts with reserved [mem 0x00000000-0x0000ffff] [ 3.308377] pci 0000:ff:1e.3: BAR 0: can't assign mem pref (size 0x10) [ 3.308729] pci 0000:00:1c.4: BAR 15: assigned [mem 0x90000000-0x900fffff 64bit pref] [ 3.309338] pci 0000:00:01.0: PCI bridge to [bus 01-01] [ 3.309680] pci 0000:00:01.0: bridge window [io disabled] [ 3.310019] pci 0000:00:01.0: bridge window [mem disabled] [ 3.310358] pci 0000:00:01.0: bridge window [mem pref disabled] [ 3.310703] pci 0000:00:02.0: PCI bridge to [bus 02-02] [ 3.311040] pci 0000:00:02.0: bridge window [io disabled] [ 3.311380] pci 0000:00:02.0: bridge window [mem disabled] [ 3.311724] pci 0000:00:02.0: bridge window [mem pref disabled] [ 3.312065] pci 0000:03:00.0: PCI bridge to [bus 04-04] [ 3.312402] pci 0000:03:00.0: bridge window [io disabled] [ 3.312751] pci 0000:03:00.0: bridge window [mem disabled] [ 3.313092] pci 0000:03:00.0: bridge window [mem pref disabled] [ 3.313439] pci 0000:00:02.2: PCI bridge to [bus 03-04] [ 3.313780] pci 0000:00:02.2: bridge window [io disabled] [ 3.314120] pci 0000:00:02.2: bridge window [mem 0xf4000000-0xf88fffff] [ 3.314461] pci 0000:00:02.2: bridge window [mem 0xd0000000-0xdfffffff 64bit pref] [ 3.315078] pci 0000:08:09.0: BAR 13: can't assign io (size 0x1000) [ 3.315419] pci 0000:08:07.0: BAR 14: can't assign mem (size 0x200000) [ 3.315764] pci 0000:08:07.0: BAR 15: can't assign mem pref (size 0x200000) [ 3.316105] pci 0000:08:07.0: BAR 13: can't assign io (size 0x1000) [ 3.316446] pci 0000:08:05.0: BAR 14: can't assign mem (size 0x200000) [ 3.316791] pci 0000:08:05.0: BAR 15: can't assign mem pref (size 0x200000) [ 3.317133] pci 0000:08:05.0: BAR 13: can't assign io (size 0x1000) [ 3.317472] pci 0000:08:01.0: BAR 14: can't assign mem (size 0x200000) [ 3.325487] pci 0000:08:01.0: BAR 15: can't assign mem pref (size 0x200000) [ 3.325833] pci 0000:08:01.0: BAR 13: can't assign io (size 0x1000) [ 3.326173] pci 0000:08:01.0: PCI bridge to [bus 09-09] [ 3.326512] pci 0000:08:01.0: bridge window [io disabled] [ 3.326989] pci 0000:08:01.0: bridge window [mem disabled] [ 3.327415] pci 0000:08:01.0: bridge window [mem pref disabled] [ 3.327937] pci 0000:08:05.0: PCI bridge to [bus 0a-0a] [ 3.328274] pci 0000:08:05.0: bridge window [io disabled] [ 3.328748] pci 0000:08:05.0: bridge window [mem disabled] [ 3.329175] pci 0000:08:05.0: bridge window [mem pref disabled] [ 3.329695] pci 0000:08:07.0: PCI bridge to [bus 0b-0b] [ 3.330032] pci 0000:08:07.0: bridge window [io disabled] [ 3.330503] pci 0000:08:07.0: bridge window [mem disabled] [ 3.330934] pci 0000:08:07.0: bridge window [mem pref disabled] [ 3.331452] pci 0000:0c:00.0: PCI bridge to [bus 0d-0d] [ 3.331794] pci 0000:0c:00.0: bridge window [io disabled] [ 3.332270] pci 0000:0c:00.0: bridge window [mem disabled] [ 3.332703] pci 0000:0c:00.0: bridge window [mem pref disabled] [ 3.333226] pci 0000:08:09.0: PCI bridge to [bus 0c-0d] [ 3.333563] pci 0000:08:09.0: bridge window [io disabled] [ 3.334039] pci 0000:08:09.0: bridge window [mem 0xec000000-0xf08fffff] [ 3.334469] pci 0000:08:09.0: bridge window [mem 0xc0000000-0xcfffffff 64bit pref] [ 3.335259] pci 0000:07:00.0: PCI bridge to [bus 08-0d] [ 3.335596] pci 0000:07:00.0: bridge window [io disabled] [ 3.336072] pci 0000:07:00.0: bridge window [mem 0xec000000-0xf08fffff] [ 3.336502] pci 0000:07:00.0: bridge window [mem 0xc0000000-0xcfffffff 64bit pref] [ 3.337292] pci 0000:06:01.0: PCI bridge to [bus 07-0d] [ 3.337633] pci 0000:06:01.0: bridge window [io disabled] [ 3.337974] pci 0000:06:01.0: bridge window [mem 0xec000000-0xf09fffff] [ 3.338317] pci 0000:06:01.0: bridge window [mem 0xc0000000-0xcfffffff 64bit pref] [ 3.338933] pci 0000:05:00.0: PCI bridge to [bus 06-0d] [ 3.339270] pci 0000:05:00.0: bridge window [io disabled] [ 3.339615] pci 0000:05:00.0: bridge window [mem 0xec000000-0xf09fffff] [ 3.339958] pci 0000:05:00.0: bridge window [mem 0xc0000000-0xcfffffff 64bit pref] [ 3.340569] pci 0000:00:03.0: PCI bridge to [bus 05-0d] [ 3.340909] pci 0000:00:03.0: bridge window [io disabled] [ 3.341249] pci 0000:00:03.0: bridge window [mem 0xec000000-0xf0afffff] [ 3.341591] pci 0000:00:03.0: bridge window [mem 0xc0000000-0xcfffffff 64bit pref] [ 3.342207] pci 0000:11:09.0: BAR 13: can't assign io (size 0x1000) [ 3.342547] pci 0000:11:07.0: BAR 14: can't assign mem (size 0x200000) [ 3.342893] pci 0000:11:07.0: BAR 15: can't assign mem pref (size 0x200000) [ 3.343234] pci 0000:11:07.0: BAR 13: can't assign io (size 0x1000) [ 3.343574] pci 0000:11:05.0: BAR 14: can't assign mem (size 0x200000) [ 3.343920] pci 0000:11:05.0: BAR 15: can't assign mem pref (size 0x200000) [ 3.344261] pci 0000:11:05.0: BAR 13: can't assign io (size 0x1000) [ 3.344605] pci 0000:11:01.0: BAR 14: can't assign mem (size 0x200000) [ 3.344946] pci 0000:11:01.0: BAR 15: can't assign mem pref (size 0x200000) [ 3.345287] pci 0000:11:01.0: BAR 13: can't assign io (size 0x1000) [ 3.345630] pci 0000:11:01.0: PCI bridge to [bus 12-12] [ 3.345968] pci 0000:11:01.0: bridge window [io disabled] [ 3.346440] pci 0000:11:01.0: bridge window [mem disabled] [ 3.346871] pci 0000:11:01.0: bridge window [mem pref disabled] [ 3.347389] pci 0000:11:05.0: PCI bridge to [bus 13-13] [ 3.347729] pci 0000:11:05.0: bridge window [io disabled] [ 3.348202] pci 0000:11:05.0: bridge window [mem disabled] [ 3.348632] pci 0000:11:05.0: bridge window [mem pref disabled] [ 3.349151] pci 0000:11:07.0: PCI bridge to [bus 14-14] [ 3.349488] pci 0000:11:07.0: bridge window [io disabled] [ 3.349963] pci 0000:11:07.0: bridge window [mem disabled] [ 3.350391] pci 0000:11:07.0: bridge window [mem pref disabled] [ 3.350913] pci 0000:15:00.0: PCI bridge to [bus 16-16] [ 3.351250] pci 0000:15:00.0: bridge window [io disabled] [ 3.351730] pci 0000:15:00.0: bridge window [mem disabled] [ 3.352161] pci 0000:15:00.0: bridge window [mem pref disabled] [ 3.352689] pci 0000:11:09.0: PCI bridge to [bus 15-16] [ 3.353026] pci 0000:11:09.0: bridge window [io disabled] [ 3.353498] pci 0000:11:09.0: bridge window [mem 0xe4000000-0xe88fffff] [ 3.353932] pci 0000:11:09.0: bridge window [mem 0xb0000000-0xbfffffff 64bit pref] [ 3.354722] pci 0000:10:00.0: PCI bridge to [bus 11-16] [ 3.355060] pci 0000:10:00.0: bridge window [io disabled] [ 3.355532] pci 0000:10:00.0: bridge window [mem 0xe4000000-0xe88fffff] [ 3.355966] pci 0000:10:00.0: bridge window [mem 0xb0000000-0xbfffffff 64bit pref] [ 3.356756] pci 0000:0f:01.0: PCI bridge to [bus 10-16] [ 3.357093] pci 0000:0f:01.0: bridge window [io disabled] [ 3.357434] pci 0000:0f:01.0: bridge window [mem 0xe4000000-0xe89fffff] [ 3.357780] pci 0000:0f:01.0: bridge window [mem 0xb0000000-0xbfffffff 64bit pref] [ 3.358391] pci 0000:0e:00.0: PCI bridge to [bus 0f-16] [ 3.358731] pci 0000:0e:00.0: bridge window [io disabled] [ 3.359073] pci 0000:0e:00.0: bridge window [mem 0xe4000000-0xe89fffff] [ 3.359415] pci 0000:0e:00.0: bridge window [mem 0xb0000000-0xbfffffff 64bit pref] [ 3.360029] pci 0000:00:03.2: PCI bridge to [bus 0e-16] [ 3.360366] pci 0000:00:03.2: bridge window [io disabled] [ 3.360709] pci 0000:00:03.2: bridge window [mem 0xe4000000-0xe8afffff] [ 3.361051] pci 0000:00:03.2: bridge window [mem 0xb0000000-0xbfffffff 64bit pref] [ 3.361664] pci 0000:00:1c.0: PCI bridge to [bus 17-17] [ 3.362001] pci 0000:00:1c.0: bridge window [io disabled] [ 3.362342] pci 0000:00:1c.0: bridge window [mem disabled] [ 3.362685] pci 0000:00:1c.0: bridge window [mem pref disabled] [ 3.363028] pci 0000:18:00.0: PCI bridge to [bus 19-19] [ 3.363367] pci 0000:18:00.0: bridge window [io 0xe000-0xefff] [ 3.363714] pci 0000:18:00.0: bridge window [mem 0xf9000000-0xfa0fffff] [ 3.364058] pci 0000:18:00.0: bridge window [mem pref disabled] [ 3.364403] pci 0000:00:1c.2: PCI bridge to [bus 18-19] [ 3.364745] pci 0000:00:1c.2: bridge window [io 0xe000-0xefff] [ 3.365086] pci 0000:00:1c.2: bridge window [mem 0xf9000000-0xfa0fffff] [ 3.365429] pci 0000:00:1c.2: bridge window [mem pref disabled] [ 3.365788] pci 0000:1a:00.0: reg 184: [mem 0x00000000-0x00003fff 64bit pref] [ 3.365802] pci 0000:1a:00.0: reg 190: [mem 0x00000000-0x00003fff 64bit pref] [ 3.365817] pci 0000:1a:00.0: reg 184: [mem 0x00000000-0x00003fff 64bit pref] [ 3.365831] pci 0000:1a:00.1: reg 184: [mem 0x00000000-0x00003fff 64bit pref] [ 3.365845] pci 0000:1a:00.0: reg 184: [mem 0x00000000-0x00003fff 64bit pref] [ 3.365860] pci 0000:1a:00.0: reg 190: [mem 0x00000000-0x00003fff 64bit pref] [ 3.365874] pci 0000:1a:00.1: reg 190: [mem 0x00000000-0x00003fff 64bit pref] [ 3.365888] pci 0000:1a:00.0: reg 184: [mem 0x00000000-0x00003fff 64bit pref] [ 3.365903] pci 0000:1a:00.0: reg 190: [mem 0x00000000-0x00003fff 64bit pref] [ 3.365917] pci 0000:1a:00.1: reg 184: [mem 0x00000000-0x00003fff 64bit pref] [ 3.365931] pci 0000:1a:00.0: reg 184: [mem 0x00000000-0x00003fff 64bit pref] [ 3.365946] pci 0000:1a:00.0: reg 184: [mem 0x00000000-0x00003fff 64bit pref] [ 3.365948] pci 0000:1a:00.0: BAR 7: assigned [mem 0x90000000-0x9001ffff 64bit pref] [ 3.366564] pci 0000:1a:00.0: BAR 7: set to [mem 0x90000000-0x9001ffff 64bit pref] (PCI address [0x90000000-0x9001ffff]) [ 3.367192] pci 0000:1a:00.0: reg 190: [mem 0x00000000-0x00003fff 64bit pref] [ 3.367206] pci 0000:1a:00.0: reg 190: [mem 0x00000000-0x00003fff 64bit pref] [ 3.367208] pci 0000:1a:00.0: BAR 10: assigned [mem 0x90020000-0x9003ffff 64bit pref] [ 3.367823] pci 0000:1a:00.0: BAR 10: set to [mem 0x90020000-0x9003ffff 64bit pref] (PCI address [0x90020000-0x9003ffff]) [ 3.368451] pci 0000:1a:00.1: reg 184: [mem 0x00000000-0x00003fff 64bit pref] [ 3.368465] pci 0000:1a:00.1: reg 184: [mem 0x00000000-0x00003fff 64bit pref] [ 3.368467] pci 0000:1a:00.1: BAR 7: assigned [mem 0x90040000-0x9005ffff 64bit pref] [ 3.369083] pci 0000:1a:00.1: BAR 7: set to [mem 0x90040000-0x9005ffff 64bit pref] (PCI address [0x90040000-0x9005ffff]) [ 3.369714] pci 0000:1a:00.1: reg 190: [mem 0x00000000-0x00003fff 64bit pref] [ 3.369728] pci 0000:1a:00.1: reg 190: [mem 0x00000000-0x00003fff 64bit pref] [ 3.369730] pci 0000:1a:00.1: BAR 10: assigned [mem 0x90060000-0x9007ffff 64bit pref] [ 3.370343] pci 0000:1a:00.1: BAR 10: set to [mem 0x90060000-0x9007ffff 64bit pref] (PCI address [0x90060000-0x9007ffff]) [ 3.370961] pci 0000:00:1c.4: PCI bridge to [bus 1a-1a] [ 3.371299] pci 0000:00:1c.4: bridge window [io 0xd000-0xdfff] [ 3.371644] pci 0000:00:1c.4: bridge window [mem 0xfa200000-0xfa2fffff] [ 3.371986] pci 0000:00:1c.4: bridge window [mem 0x90000000-0x900fffff 64bit pref] [ 3.372611] pci 0000:00:01.0: PCI INT A -> GSI 26 (level, low) -> IRQ 26 [ 3.372953] pci 0000:00:01.0: setting latency timer to 64 [ 3.372960] pci 0000:00:02.0: PCI INT A -> GSI 32 (level, low) -> IRQ 32 [ 3.373301] pci 0000:00:02.0: setting latency timer to 64 [ 3.373305] pci 0000:00:02.2: PCI INT A -> GSI 32 (level, low) -> IRQ 32 [ 3.373650] pci 0000:00:02.2: setting latency timer to 64 [ 3.373657] pci 0000:03:00.0: setting latency timer to 64 [ 3.373665] pci 0000:00:03.0: PCI INT A -> GSI 40 (level, low) -> IRQ 40 [ 3.374007] pci 0000:00:03.0: setting latency timer to 64 [ 3.374012] pci 0000:05:00.0: PCI INT A -> GSI 40 (level, low) -> IRQ 40 [ 3.374354] pci 0000:05:00.0: setting latency timer to 64 [ 3.374362] pci 0000:06:01.0: PCI INT A -> GSI 44 (level, low) -> IRQ 44 [ 3.374707] pci 0000:06:01.0: setting latency timer to 64 [ 3.374800] pci 0000:07:00.0: PCI INT A -> GSI 44 (level, low) -> IRQ 44 [ 3.375229] pci 0000:07:00.0: setting latency timer to 64 [ 3.375368] pci 0000:08:01.0: PCI INT A -> GSI 45 (level, low) -> IRQ 45 [ 3.375801] pci 0000:08:01.0: setting latency timer to 64 [ 3.375938] pci 0000:08:05.0: PCI INT A -> GSI 45 (level, low) -> IRQ 45 [ 3.376367] pci 0000:08:05.0: setting latency timer to 64 [ 3.376503] pci 0000:08:07.0: PCI INT A -> GSI 40 (level, low) -> IRQ 40 [ 3.376936] pci 0000:08:07.0: setting latency timer to 64 [ 3.377073] pci 0000:08:09.0: PCI INT A -> GSI 45 (level, low) -> IRQ 45 [ 3.377502] pci 0000:08:09.0: setting latency timer to 64 [ 3.377733] pci 0000:0c:00.0: setting latency timer to 64 [ 3.377782] pci 0000:00:03.2: PCI INT A -> GSI 40 (level, low) -> IRQ 40 [ 3.378123] pci 0000:00:03.2: setting latency timer to 64 [ 3.378131] pci 0000:0e:00.0: PCI INT A -> GSI 42 (level, low) -> IRQ 42 [ 3.378473] pci 0000:0e:00.0: setting latency timer to 64 [ 3.378478] pci 0000:0f:01.0: PCI INT A -> GSI 45 (level, low) -> IRQ 45 [ 3.378824] pci 0000:0f:01.0: setting latency timer to 64 [ 3.378917] pci 0000:10:00.0: PCI INT A -> GSI 45 (level, low) -> IRQ 45 [ 3.379347] pci 0000:10:00.0: setting latency timer to 64 [ 3.379485] pci 0000:11:01.0: PCI INT A -> GSI 44 (level, low) -> IRQ 44 [ 3.379918] pci 0000:11:01.0: setting latency timer to 64 [ 3.380056] pci 0000:11:05.0: PCI INT A -> GSI 44 (level, low) -> IRQ 44 [ 3.380485] pci 0000:11:05.0: setting latency timer to 64 [ 3.380626] pci 0000:11:07.0: PCI INT A -> GSI 42 (level, low) -> IRQ 42 [ 3.381056] pci 0000:11:07.0: setting latency timer to 64 [ 3.381194] pci 0000:11:09.0: PCI INT A -> GSI 44 (level, low) -> IRQ 44 [ 3.381627] pci 0000:11:09.0: setting latency timer to 64 [ 3.381857] pci 0000:15:00.0: setting latency timer to 64 [ 3.381910] pci 0000:00:1c.0: PCI INT A -> GSI 16 (level, low) -> IRQ 16 [ 3.382252] pci 0000:00:1c.0: setting latency timer to 64 [ 3.382259] pci 0000:00:1c.2: PCI INT C -> GSI 18 (level, low) -> IRQ 18 [ 3.382604] pci 0000:00:1c.2: setting latency timer to 64 [ 3.382613] pci 0000:18:00.0: setting latency timer to 64 [ 3.382619] pci 0000:00:1c.4: PCI INT A -> GSI 16 (level, low) -> IRQ 16 [ 3.382961] pci 0000:00:1c.4: setting latency timer to 64 [ 3.382965] pci_bus 0000:00: resource 4 [io 0x0000-0x0cf7] [ 3.382966] pci_bus 0000:00: resource 5 [io 0x1000-0xffff] [ 3.382968] pci_bus 0000:00: resource 6 [mem 0x000a0000-0x000bffff] [ 3.382969] pci_bus 0000:00: resource 7 [mem 0xfedb0000-0xfedb000f] [ 3.382971] pci_bus 0000:00: resource 8 [mem 0xfedc0000-0xfedc000f] [ 3.382972] pci_bus 0000:00: resource 9 [mem 0x90000000-0xfbffbfff] [ 3.382974] pci_bus 0000:03: resource 1 [mem 0xf4000000-0xf88fffff] [ 3.382976] pci_bus 0000:03: resource 2 [mem 0xd0000000-0xdfffffff 64bit pref] [ 3.382977] pci_bus 0000:05: resource 1 [mem 0xec000000-0xf0afffff] [ 3.382979] pci_bus 0000:05: resource 2 [mem 0xc0000000-0xcfffffff 64bit pref] [ 3.382980] pci_bus 0000:06: resource 1 [mem 0xec000000-0xf09fffff] [ 3.382982] pci_bus 0000:06: resource 2 [mem 0xc0000000-0xcfffffff 64bit pref] [ 3.382983] pci_bus 0000:07: resource 1 [mem 0xec000000-0xf09fffff] [ 3.382985] pci_bus 0000:07: resource 2 [mem 0xc0000000-0xcfffffff 64bit pref] [ 3.382986] pci_bus 0000:08: resource 1 [mem 0xec000000-0xf08fffff] [ 3.382988] pci_bus 0000:08: resource 2 [mem 0xc0000000-0xcfffffff 64bit pref] [ 3.382990] pci_bus 0000:0c: resource 1 [mem 0xec000000-0xf08fffff] [ 3.382991] pci_bus 0000:0c: resource 2 [mem 0xc0000000-0xcfffffff 64bit pref] [ 3.382993] pci_bus 0000:0e: resource 1 [mem 0xe4000000-0xe8afffff] [ 3.382994] pci_bus 0000:0e: resource 2 [mem 0xb0000000-0xbfffffff 64bit pref] [ 3.382996] pci_bus 0000:0f: resource 1 [mem 0xe4000000-0xe89fffff] [ 3.382997] pci_bus 0000:0f: resource 2 [mem 0xb0000000-0xbfffffff 64bit pref] [ 3.382999] pci_bus 0000:10: resource 1 [mem 0xe4000000-0xe89fffff] [ 3.383001] pci_bus 0000:10: resource 2 [mem 0xb0000000-0xbfffffff 64bit pref] [ 3.383002] pci_bus 0000:11: resource 1 [mem 0xe4000000-0xe88fffff] [ 3.383004] pci_bus 0000:11: resource 2 [mem 0xb0000000-0xbfffffff 64bit pref] [ 3.383005] pci_bus 0000:15: resource 1 [mem 0xe4000000-0xe88fffff] [ 3.383007] pci_bus 0000:15: resource 2 [mem 0xb0000000-0xbfffffff 64bit pref] [ 3.383009] pci_bus 0000:18: resource 0 [io 0xe000-0xefff] [ 3.383010] pci_bus 0000:18: resource 1 [mem 0xf9000000-0xfa0fffff] [ 3.383012] pci_bus 0000:19: resource 0 [io 0xe000-0xefff] [ 3.383013] pci_bus 0000:19: resource 1 [mem 0xf9000000-0xfa0fffff] [ 3.383015] pci_bus 0000:1a: resource 0 [io 0xd000-0xdfff] [ 3.383016] pci_bus 0000:1a: resource 1 [mem 0xfa200000-0xfa2fffff] [ 3.383017] pci_bus 0000:1a: resource 2 [mem 0x90000000-0x900fffff 64bit pref] [ 3.383034] NET: Registered protocol family 2 [ 3.383689] IP route cache hash table entries: 524288 (order: 10, 4194304 bytes) [ 3.385211] TCP established hash table entries: 524288 (order: 11, 8388608 bytes) [ 3.386733] TCP bind hash table entries: 65536 (order: 8, 1048576 bytes) [ 3.387178] TCP: Hash tables configured (established 524288 bind 65536) [ 3.387518] TCP reno registered [ 3.387892] UDP hash table entries: 16384 (order: 7, 524288 bytes) [ 3.388326] UDP-Lite hash table entries: 16384 (order: 7, 524288 bytes) [ 3.388776] NET: Registered protocol family 1 [ 3.389162] RPC: Registered named UNIX socket transport module. [ 3.389501] RPC: Registered udp transport module. [ 3.389842] RPC: Registered tcp transport module. [ 3.390178] RPC: Registered tcp NFSv4.1 backchannel transport module. [ 3.390648] pci 0000:00:1a.0: EHCI: BIOS handoff [ 3.406540] pci 0000:00:1d.0: EHCI: BIOS handoff [ 3.423256] pci 0000:19:00.0: Boot video device [ 3.423263] PCI: CLS 64 bytes, default 64 [ 3.423293] PCI-DMA: Using software bounce buffering for IO (SWIOTLB) [ 3.423638] Placing 64MB software IO TLB between ffff880074f58000 - ffff880078f58000 [ 3.424245] software IO TLB at phys 0x74f58000 - 0x78f58000 [ 3.427044] audit: initializing netlink socket (disabled) [ 3.427386] type=2000 audit(1571092959.099:1): initialized [ 3.462785] HugeTLB registered 2 MB page size, pre-allocated 0 pages [ 3.465650] VFS: Disk quotas dquot_6.5.2 [ 3.466043] Dquot-cache hash table entries: 512 (order 0, 4096 bytes) [ 3.467147] Installing knfsd (copyright (C) 1996 okir@monad.swb.de). [ 3.467732] msgmni has been set to 32768 [ 3.468377] Block layer SCSI generic (bsg) driver version 0.4 loaded (major 253) [ 3.468992] io scheduler noop registered [ 3.469326] io scheduler deadline registered [ 3.469713] io scheduler cfq registered (default) [ 3.477937] pcieport 0000:00:01.0: setting latency timer to 64 [ 3.477963] pcieport 0000:00:01.0: irq 64 for MSI/MSI-X [ 3.478037] pcieport 0000:00:02.0: setting latency timer to 64 [ 3.478058] pcieport 0000:00:02.0: irq 65 for MSI/MSI-X [ 3.478126] pcieport 0000:00:02.2: setting latency timer to 64 [ 3.478145] pcieport 0000:00:02.2: irq 66 for MSI/MSI-X [ 3.478215] pcieport 0000:00:03.0: setting latency timer to 64 [ 3.478235] pcieport 0000:00:03.0: irq 67 for MSI/MSI-X [ 3.478302] pcieport 0000:00:03.2: setting latency timer to 64 [ 3.478323] pcieport 0000:00:03.2: irq 68 for MSI/MSI-X [ 3.478408] pcieport 0000:00:1c.0: setting latency timer to 64 [ 3.478439] pcieport 0000:00:1c.0: irq 69 for MSI/MSI-X [ 3.478525] pcieport 0000:00:1c.2: setting latency timer to 64 [ 3.478556] pcieport 0000:00:1c.2: irq 70 for MSI/MSI-X [ 3.478640] pcieport 0000:00:1c.4: setting latency timer to 64 [ 3.478671] pcieport 0000:00:1c.4: irq 71 for MSI/MSI-X [ 3.478758] pcieport 0000:03:00.0: setting latency timer to 64 [ 3.478884] pcieport 0000:05:00.0: setting latency timer to 64 [ 3.478920] pcieport 0000:05:00.0: irq 72 for MSI/MSI-X [ 3.479004] pcieport 0000:06:01.0: setting latency timer to 64 [ 3.479040] pcieport 0000:06:01.0: irq 73 for MSI/MSI-X [ 3.479482] pcieport 0000:07:00.0: setting latency timer to 64 [ 3.481131] pcieport 0000:07:00.0: irq 74 for MSI/MSI-X [ 3.483317] pcieport 0000:08:01.0: setting latency timer to 64 [ 3.484969] pcieport 0000:08:01.0: irq 75 for MSI/MSI-X [ 3.487184] pcieport 0000:08:05.0: setting latency timer to 64 [ 3.488836] pcieport 0000:08:05.0: irq 76 for MSI/MSI-X [ 3.491045] pcieport 0000:08:07.0: setting latency timer to 64 [ 3.492697] pcieport 0000:08:07.0: irq 77 for MSI/MSI-X [ 3.494907] pcieport 0000:08:09.0: setting latency timer to 64 [ 3.496559] pcieport 0000:08:09.0: irq 78 for MSI/MSI-X [ 3.498642] pcieport 0000:0c:00.0: setting latency timer to 64 [ 3.500934] pcieport 0000:0e:00.0: setting latency timer to 64 [ 3.500970] pcieport 0000:0e:00.0: irq 79 for MSI/MSI-X [ 3.501055] pcieport 0000:0f:01.0: setting latency timer to 64 [ 3.501091] pcieport 0000:0f:01.0: irq 80 for MSI/MSI-X [ 3.501536] pcieport 0000:10:00.0: setting latency timer to 64 [ 3.503210] pcieport 0000:10:00.0: irq 81 for MSI/MSI-X [ 3.505418] pcieport 0000:11:01.0: setting latency timer to 64 [ 3.507081] pcieport 0000:11:01.0: irq 82 for MSI/MSI-X [ 3.509307] pcieport 0000:11:05.0: setting latency timer to 64 [ 3.510977] pcieport 0000:11:05.0: irq 83 for MSI/MSI-X [ 3.513205] pcieport 0000:11:07.0: setting latency timer to 64 [ 3.514872] pcieport 0000:11:07.0: irq 84 for MSI/MSI-X [ 3.517101] pcieport 0000:11:09.0: setting latency timer to 64 [ 3.518771] pcieport 0000:11:09.0: irq 85 for MSI/MSI-X [ 3.520876] pcieport 0000:15:00.0: setting latency timer to 64 [ 3.523459] input: Power Button as /devices/LNXSYSTM:00/device:00/PNP0C0C:00/input/input0 [ 3.524070] ACPI: Power Button [PWRB] [ 3.524461] input: Power Button as /devices/LNXSYSTM:00/LNXPWRBN:00/input/input1 [ 3.525069] ACPI: Power Button [PWRF] [ 3.525544] ACPI: acpi_idle registered with cpuidle [ 3.525789] Monitor-Mwait will be used to enter C-1 state [ 3.525809] Monitor-Mwait will be used to enter C-2 state [ 3.532153] Serial: 8250/16550 driver, 4 ports, IRQ sharing enabled [ 3.798507] serial8250: ttyS0 at I/O 0x3f8 (irq = 4) is a 16550A [ 4.075075] serial8250: ttyS1 at I/O 0x2f8 (irq = 3) is a 16550A [ 4.138105] 00:0a: ttyS0 at I/O 0x3f8 (irq = 4) is a 16550A [ 4.174976] 00:0b: ttyS1 at I/O 0x2f8 (irq = 3) is a 16550A [ 4.191767] Non-volatile memory driver v1.3 [ 4.192111] Linux agpgart interface v0.103 [ 4.192623] ipmi message handler version 39.2 [ 4.192969] ipmi device interface [ 4.193377] IPMI System Interface driver. [ 4.193764] ipmi_si: probing via ACPI [ 4.194113] ipmi_si 00:0c: [io 0x0ca2] regsize 1 spacing 1 irq 0 [ 4.194468] ipmi_si: Adding ACPI-specified kcs state machine [ 4.194906] ipmi_si: probing via SMBIOS [ 4.195247] ipmi_si: SMBIOS: io 0xca2 regsize 1 spacing 1 irq 0 [ 4.195600] ipmi_si: Adding SMBIOS-specified kcs state machine duplicate interface [ 4.196290] ipmi_si: probing via SPMI [ 4.196632] ipmi_si: SPMI: io 0xca2 regsize 1 spacing 1 irq 0 [ 4.196978] ipmi_si: Adding SPMI-specified kcs state machine duplicate interface [ 4.197667] ipmi_si: Trying ACPI-specified kcs state machine at i/o address 0xca2, slave address 0x0, irq 0 [ 4.226943] ipmi_si 00:0c: Found new BMC (man_id: 0x002a7c, prod_id: 0x0833, dev_id: 0x20) [ 4.227619] ipmi_si 00:0c: IPMI kcs interface initialized [ 4.228681] IPMI Watchdog: driver initialized [ 4.229025] Copyright (C) 2004 MontaVista Software - IPMI Powerdown via sys_reboot. [ 4.230013] IPMI poweroff: ATCA Detect mfg 0x2A7C prod 0x833 [ 4.230367] IPMI poweroff: Found a chassis style poweroff function [ 4.230758] [drm] Initialized drm 1.1.0 20060810 [ 4.231103] [drm:i915_init] *ERROR* drm/i915 can't work without intel_agp module! [ 4.233153] brd: module loaded [ 4.234214] loop: module loaded [ 4.234830] ahci 0000:00:11.4: version 3.0 [ 4.234843] ahci 0000:00:11.4: PCI INT A -> GSI 16 (level, low) -> IRQ 16 [ 4.235259] ahci 0000:00:11.4: irq 86 for MSI/MSI-X [ 4.235316] ahci 0000:00:11.4: AHCI 0001.0300 32 slots 4 ports 6 Gbps 0xf impl SATA mode [ 4.235940] ahci 0000:00:11.4: flags: 64bit ncq pm led clo pio slum part ems apst [ 4.236587] ahci 0000:00:11.4: setting latency timer to 64 [ 4.242732] scsi0 : ahci [ 4.243178] scsi1 : ahci [ 4.243617] scsi2 : ahci [ 4.244042] scsi3 : ahci [ 4.244502] ata1: SATA max UDMA/133 abar m2048@0xe8b38000 port 0xe8b38100 irq 86 [ 4.245122] ata2: SATA max UDMA/133 abar m2048@0xe8b38000 port 0xe8b38180 irq 86 [ 4.245748] ata3: SATA max UDMA/133 abar m2048@0xe8b38000 port 0xe8b38200 irq 86 [ 4.246372] ata4: SATA max UDMA/133 abar m2048@0xe8b38000 port 0xe8b38280 irq 86 [ 4.246996] work_for_cpu used greatest stack depth: 5560 bytes left [ 4.247387] ahci 0000:00:1f.2: PCI INT A -> GSI 16 (level, low) -> IRQ 16 [ 4.247763] ahci 0000:00:1f.2: irq 87 for MSI/MSI-X [ 4.247823] ahci 0000:00:1f.2: AHCI 0001.0300 32 slots 6 ports 6 Gbps 0x3f impl SATA mode [ 4.248456] ahci 0000:00:1f.2: flags: 64bit ncq pm led clo pio slum part ems apst [ 4.249077] ahci 0000:00:1f.2: setting latency timer to 64 [ 4.259012] scsi4 : ahci [ 4.259452] scsi5 : ahci [ 4.259873] scsi6 : ahci [ 4.260302] scsi7 : ahci [ 4.260724] scsi8 : ahci [ 4.261145] scsi9 : ahci [ 4.261617] ata5: SATA max UDMA/133 abar m2048@0xe8b32000 port 0xe8b32100 irq 87 [ 4.262244] ata6: SATA max UDMA/133 abar m2048@0xe8b32000 port 0xe8b32180 irq 87 [ 4.262864] ata7: SATA max UDMA/133 abar m2048@0xe8b32000 port 0xe8b32200 irq 87 [ 4.263491] ata8: SATA max UDMA/133 abar m2048@0xe8b32000 port 0xe8b32280 irq 87 [ 4.264111] ata9: SATA max UDMA/133 abar m2048@0xe8b32000 port 0xe8b32300 irq 87 [ 4.264738] ata10: SATA max UDMA/133 abar m2048@0xe8b32000 port 0xe8b32380 irq 87 [ 4.265816] e1000: Intel(R) PRO/1000 Network Driver - version 7.3.21-k8-NAPI [ 4.266177] e1000: Copyright (c) 1999-2006 Intel Corporation. [ 4.266565] e1000e: Intel(R) PRO/1000 Network Driver - 1.3.10-k2 [ 4.266911] e1000e: Copyright(c) 1999 - 2011 Intel Corporation. [ 4.267316] Intel(R) Gigabit Ethernet Network Driver - version 3.0.6-k2 [ 4.267664] Copyright (c) 2007-2011 Intel Corporation. [ 4.268053] igb 0000:1a:00.0: PCI INT A -> GSI 16 (level, low) -> IRQ 16 [ 4.268421] igb 0000:1a:00.0: setting latency timer to 64 [ 4.268689] igb 0000:1a:00.0: irq 88 for MSI/MSI-X [ 4.268693] igb 0000:1a:00.0: irq 89 for MSI/MSI-X [ 4.268697] igb 0000:1a:00.0: irq 90 for MSI/MSI-X [ 4.268701] igb 0000:1a:00.0: irq 91 for MSI/MSI-X [ 4.268706] igb 0000:1a:00.0: irq 92 for MSI/MSI-X [ 4.268710] igb 0000:1a:00.0: irq 93 for MSI/MSI-X [ 4.268714] igb 0000:1a:00.0: irq 94 for MSI/MSI-X [ 4.268718] igb 0000:1a:00.0: irq 95 for MSI/MSI-X [ 4.268723] igb 0000:1a:00.0: irq 96 for MSI/MSI-X [ 4.268746] igb 0000:1a:00.0: 0 vfs allocated [ 4.322893] igb 0000:1a:00.0: Intel(R) Gigabit Ethernet Network Connection [ 4.323251] igb 0000:1a:00.0: eth0: (PCIe:5.0Gb/s:Width x4) 0c:c4:7a:db:65:b0 [ 4.323681] igb 0000:1a:00.0: eth0: PBA No: 050B00-000 [ 4.324025] igb 0000:1a:00.0: Using MSI-X interrupts. 8 rx queue(s), 8 tx queue(s) [ 4.324696] igb 0000:1a:00.1: PCI INT B -> GSI 17 (level, low) -> IRQ 17 [ 4.325053] igb 0000:1a:00.1: setting latency timer to 64 [ 4.325326] igb 0000:1a:00.1: irq 97 for MSI/MSI-X [ 4.325330] igb 0000:1a:00.1: irq 98 for MSI/MSI-X [ 4.325335] igb 0000:1a:00.1: irq 99 for MSI/MSI-X [ 4.325339] igb 0000:1a:00.1: irq 100 for MSI/MSI-X [ 4.325343] igb 0000:1a:00.1: irq 101 for MSI/MSI-X [ 4.325347] igb 0000:1a:00.1: irq 102 for MSI/MSI-X [ 4.325351] igb 0000:1a:00.1: irq 103 for MSI/MSI-X [ 4.325358] igb 0000:1a:00.1: irq 104 for MSI/MSI-X [ 4.325363] igb 0000:1a:00.1: irq 105 for MSI/MSI-X [ 4.325385] igb 0000:1a:00.1: 0 vfs allocated [ 4.379879] igb 0000:1a:00.1: Intel(R) Gigabit Ethernet Network Connection [ 4.380237] igb 0000:1a:00.1: eth1: (PCIe:5.0Gb/s:Width x4) 0c:c4:7a:db:65:b1 [ 4.380666] igb 0000:1a:00.1: eth1: PBA No: 050B00-000 [ 4.381016] igb 0000:1a:00.1: Using MSI-X interrupts. 8 rx queue(s), 8 tx queue(s) [ 4.381682] e100: Intel(R) PRO/100 Network Driver, 3.5.24-k2-NAPI [ 4.382035] e100: Copyright(c) 1999-2006 Intel Corporation [ 4.382482] sky2: driver version 1.28 [ 4.382971] console [netcon0] enabled [ 4.383314] netconsole: network logging started [ 4.383800] ehci_hcd: USB 2.0 'Enhanced' Host Controller (EHCI) Driver [ 4.384155] ehci_hcd: block sizes: qh 112 qtd 96 itd 192 sitd 96 [ 4.384195] ehci_hcd 0000:00:1a.0: PCI INT C -> GSI 18 (level, low) -> IRQ 18 [ 4.384557] ehci_hcd 0000:00:1a.0: setting latency timer to 64 [ 4.384560] ehci_hcd 0000:00:1a.0: EHCI Host Controller [ 4.384916] drivers/usb/core/inode.c: creating file 'devices' [ 4.384919] drivers/usb/core/inode.c: creating file '001' [ 4.384977] ehci_hcd 0000:00:1a.0: new USB bus registered, assigned bus number 1 [ 4.385604] ehci_hcd 0000:00:1a.0: reset hcs_params 0x200002 dbg=2 cc=0 pcc=0 ordered !ppc ports=2 [ 4.385607] ehci_hcd 0000:00:1a.0: reset hcc_params 36881 caching frame 1024 64 bit addr [ 4.385621] ehci_hcd 0000:00:1a.0: support lpm [ 4.385630] ehci_hcd 0000:00:1a.0: debug port 2 [ 4.385982] ehci_hcd 0000:00:1a.0: reset command 0080002 (park)=0 ithresh=8 period=1024 Reset HALT [ 4.389850] ehci_hcd 0000:00:1a.0: cache line size of 64 is not supported [ 4.389852] ehci_hcd 0000:00:1a.0: supports USB remote wakeup [ 4.389863] ehci_hcd 0000:00:1a.0: irq 18, io mem 0xe8b34000 [ 4.390218] ehci_hcd 0000:00:1a.0: reset command 0080002 (park)=0 ithresh=8 period=1024 Reset HALT [ 4.394082] ehci_hcd 0000:00:1a.0: init command 0010001 (park)=0 ithresh=1 period=1024 RUN [ 4.399949] ehci_hcd 0000:00:1a.0: USB 2.0 started, EHCI 1.00 [ 4.400334] usb usb1: default language 0x0409 [ 4.400338] usb usb1: udev 1, busnum 1, minor = 0 [ 4.400340] usb usb1: New USB device found, idVendor=1d6b, idProduct=0002 [ 4.400687] usb usb1: New USB device strings: Mfr=3, Product=2, SerialNumber=1 [ 4.401311] usb usb1: Product: EHCI Host Controller [ 4.401654] usb usb1: Manufacturer: Linux 3.0.8 ehci_hcd [ 4.402003] usb usb1: SerialNumber: 0000:00:1a.0 [ 4.402399] usb usb1: usb_probe_device [ 4.402401] usb usb1: configuration #1 chosen from 1 choice [ 4.402409] usb usb1: adding 1-0:1.0 (config #1, interface 0) [ 4.402447] hub 1-0:1.0: usb_probe_interface [ 4.402448] hub 1-0:1.0: usb_probe_interface - got id [ 4.402450] hub 1-0:1.0: USB hub found [ 4.402793] hub 1-0:1.0: 2 ports detected [ 4.403140] hub 1-0:1.0: standalone hub [ 4.403141] hub 1-0:1.0: no power switching (usb 1.0) [ 4.403143] hub 1-0:1.0: individual port over-current protection [ 4.403144] hub 1-0:1.0: power on to power good time: 20ms [ 4.403147] hub 1-0:1.0: local power source is good [ 4.403148] hub 1-0:1.0: trying to enable port power on non-switchable hub [ 4.403160] drivers/usb/core/inode.c: creating file '001' [ 4.403209] work_for_cpu used greatest stack depth: 5448 bytes left [ 4.403570] ehci_hcd 0000:00:1d.0: PCI INT C -> GSI 18 (level, low) -> IRQ 18 [ 4.403929] ehci_hcd 0000:00:1d.0: setting latency timer to 64 [ 4.403944] ehci_hcd 0000:00:1d.0: EHCI Host Controller [ 4.404291] drivers/usb/core/inode.c: creating file '002' [ 4.404334] ehci_hcd 0000:00:1d.0: new USB bus registered, assigned bus number 2 [ 4.404964] ehci_hcd 0000:00:1d.0: reset hcs_params 0x200002 dbg=2 cc=0 pcc=0 ordered !ppc ports=2 [ 4.404966] ehci_hcd 0000:00:1d.0: reset hcc_params 36881 caching frame 1024 64 bit addr [ 4.404977] ehci_hcd 0000:00:1d.0: support lpm [ 4.404986] ehci_hcd 0000:00:1d.0: debug port 2 [ 4.405330] ehci_hcd 0000:00:1d.0: reset command 0080002 (park)=0 ithresh=8 period=1024 Reset HALT [ 4.409199] ehci_hcd 0000:00:1d.0: cache line size of 64 is not supported [ 4.409201] ehci_hcd 0000:00:1d.0: supports USB remote wakeup [ 4.409205] ehci_hcd 0000:00:1d.0: irq 18, io mem 0xe8b33000 [ 4.409551] ehci_hcd 0000:00:1d.0: reset command 0080002 (park)=0 ithresh=8 period=1024 Reset HALT [ 4.413431] ehci_hcd 0000:00:1d.0: init command 0010001 (park)=0 ithresh=1 period=1024 RUN [ 4.418919] ehci_hcd 0000:00:1d.0: USB 2.0 started, EHCI 1.00 [ 4.419294] usb usb2: default language 0x0409 [ 4.419301] usb usb2: udev 1, busnum 2, minor = 128 [ 4.419304] usb usb2: New USB device found, idVendor=1d6b, idProduct=0002 [ 4.419668] usb usb2: New USB device strings: Mfr=3, Product=2, SerialNumber=1 [ 4.420292] usb usb2: Product: EHCI Host Controller [ 4.420634] usb usb2: Manufacturer: Linux 3.0.8 ehci_hcd [ 4.420984] usb usb2: SerialNumber: 0000:00:1d.0 [ 4.421377] usb usb2: usb_probe_device [ 4.421378] usb usb2: configuration #1 chosen from 1 choice [ 4.421382] usb usb2: adding 2-0:1.0 (config #1, interface 0) [ 4.421417] hub 2-0:1.0: usb_probe_interface [ 4.421418] hub 2-0:1.0: usb_probe_interface - got id [ 4.421420] hub 2-0:1.0: USB hub found [ 4.421761] hub 2-0:1.0: 2 ports detected [ 4.422108] hub 2-0:1.0: standalone hub [ 4.422109] hub 2-0:1.0: no power switching (usb 1.0) [ 4.422110] hub 2-0:1.0: individual port over-current protection [ 4.422112] hub 2-0:1.0: power on to power good time: 20ms [ 4.422114] hub 2-0:1.0: local power source is good [ 4.422115] hub 2-0:1.0: trying to enable port power on non-switchable hub [ 4.422127] drivers/usb/core/inode.c: creating file '001' [ 4.422210] ohci_hcd: USB 1.1 'Open' Host Controller (OHCI) Driver [ 4.422557] ohci_hcd: block sizes: ed 80 td 96 [ 4.422601] uhci_hcd: USB Universal Host Controller Interface driver [ 4.423032] usbcore: registered new interface driver usblp [ 4.423376] Initializing USB Mass Storage driver... [ 4.423750] usbcore: registered new interface driver usb-storage [ 4.424103] USB Mass Storage support registered. [ 4.424476] usbcore: registered new interface driver libusual [ 4.424948] i8042: PNP: No PS/2 controller found. Probing ports directly. [ 4.425904] Refined TSC clocksource calibration: 2399.997 MHz. [ 4.426166] i8042: No controller found [ 4.426216] mousedev: PS/2 mouse device common for all mice [ 4.426436] rtc_cmos 00:04: RTC can wake from S4 [ 4.426594] rtc_cmos 00:04: rtc core: registered rtc_cmos as rtc0 [ 4.426640] rtc0: alarms up to one month, y3k, 114 bytes nvram, hpet irqs [ 4.426941] device-mapper: ioctl: 4.20.0-ioctl (2011-02-02) initialised: dm-devel@redhat.com [ 4.428157] cpuidle: using governor ladder [ 4.429124] Switching to clocksource tsc [ 4.430647] cpuidle: using governor menu [ 4.430991] EFI Variables Facility v0.08 2004-May-17 [ 4.431797] usbcore: registered new interface driver usbhid [ 4.432143] usbhid: USB HID core driver [ 4.432745] ALSA device list: [ 4.433085] No soundcards found. [ 4.433598] TCP cubic registered [ 4.433939] Initializing XFRM netlink socket [ 4.434511] NET: Registered protocol family 10 [ 4.435334] IPv6 over IPv4 tunneling driver [ 4.436038] NET: Registered protocol family 17 [ 4.436386] Registering the dns_resolver key type [ 4.436958] PM: Hibernation image not present or could not be loaded. [ 4.445862] __dma_request_channel: fail ((null)) [ 4.445873] Magic number: 7:97:755 [ 4.446216] ata_link link6: hash matches [ 4.446556] link6: hash matches [ 4.446921] pci 0000:ff:1e.4: hash matches [ 4.502811] ehci_hcd 0000:00:1a.0: GetStatus port:1 status 001803 0 ACK POWER sig=j CSC CONNECT [ 4.502815] hub 1-0:1.0: port 1: status 0501 change 0001 [ 4.521790] ehci_hcd 0000:00:1d.0: GetStatus port:1 status 001803 0 ACK POWER sig=j CSC CONNECT [ 4.521794] hub 2-0:1.0: port 1: status 0501 change 0001 [ 4.529805] ADDRCONF(NETDEV_UP): eth0: link is not ready [ 4.550741] ata2: SATA link down (SStatus 0 SControl 300) [ 4.551096] ata4: SATA link down (SStatus 0 SControl 300) [ 4.551450] ata3: SATA link down (SStatus 0 SControl 300) [ 4.552743] ata1: SATA link down (SStatus 0 SControl 300) [ 4.569710] ata7: SATA link down (SStatus 0 SControl 300) [ 4.577741] ata6: SATA link down (SStatus 0 SControl 300) [ 4.578094] ata8: SATA link down (SStatus 0 SControl 300) [ 4.578446] ata9: SATA link down (SStatus 0 SControl 300) [ 4.578797] ata10: SATA link down (SStatus 0 SControl 300) [ 4.579150] ata5: SATA link down (SStatus 0 SControl 300) [ 4.602661] hub 1-0:1.0: state 7 ports 2 chg 0002 evt 0000 [ 4.602668] hub 1-0:1.0: port 1, status 0501, change 0000, 480 Mb/s [ 4.611772] ADDRCONF(NETDEV_UP): eth1: link is not ready [ 4.653828] ehci_hcd 0000:00:1a.0: port 1 high speed [ 4.653832] ehci_hcd 0000:00:1a.0: GetStatus port:1 status 001005 0 ACK POWER sig=se0 PE CONNECT [ 4.704526] usb 1-1: new high speed USB device number 2 using ehci_hcd [ 4.755671] ehci_hcd 0000:00:1a.0: port 1 high speed [ 4.755679] ehci_hcd 0000:00:1a.0: GetStatus port:1 status 001005 0 ACK POWER sig=se0 PE CONNECT [ 4.818459] ehci_hcd 0000:00:1a.0: set dev address 2 for port 1 [ 4.818466] ehci_hcd 0000:00:1a.0: LPM: no device attached [ 4.818704] usb 1-1: udev 2, busnum 1, minor = 1 [ 4.818708] usb 1-1: New USB device found, idVendor=8087, idProduct=800a [ 4.819069] usb 1-1: New USB device strings: Mfr=0, Product=0, SerialNumber=0 [ 4.819525] usb 1-1: usb_probe_device [ 4.819527] usb 1-1: configuration #1 chosen from 1 choice [ 4.819577] usb 1-1: adding 1-1:1.0 (config #1, interface 0) [ 4.819609] hub 1-1:1.0: usb_probe_interface [ 4.819610] hub 1-1:1.0: usb_probe_interface - got id [ 4.819611] hub 1-1:1.0: USB hub found [ 4.820071] hub 1-1:1.0: 6 ports detected [ 4.820412] hub 1-1:1.0: standalone hub [ 4.820413] hub 1-1:1.0: individual port power switching [ 4.820414] hub 1-1:1.0: individual port over-current protection [ 4.820415] hub 1-1:1.0: Single TT [ 4.820416] hub 1-1:1.0: TT requires at most 8 FS bit times (666 ns) [ 4.820418] hub 1-1:1.0: power on to power good time: 0ms [ 4.820573] hub 1-1:1.0: local power source is good [ 4.820576] hub 1-1:1.0: enabling power on all ports [ 4.821335] drivers/usb/core/inode.c: creating file '002' [ 4.821354] hub 2-0:1.0: state 7 ports 2 chg 0002 evt 0000 [ 4.821361] hub 2-0:1.0: port 1, status 0501, change 0000, 480 Mb/s [ 4.872485] ehci_hcd 0000:00:1d.0: port 1 high speed [ 4.872489] ehci_hcd 0000:00:1d.0: GetStatus port:1 status 001005 0 ACK POWER sig=se0 PE CONNECT [ 4.921789] hub 1-1:1.0: port 5: status 0101 change 0001 [ 4.922038] hub 1-1:1.0: port 6: status 0101 change 0001 [ 4.923156] usb 2-1: new high speed USB device number 2 using ehci_hcd [ 4.974327] ehci_hcd 0000:00:1d.0: port 1 high speed [ 4.974331] ehci_hcd 0000:00:1d.0: GetStatus port:1 status 001005 0 ACK POWER sig=se0 PE CONNECT [ 5.022040] usb 1-1: link qh256-0001/ffff88085ec5f300 start 1 [1/0 us] [ 5.037118] ehci_hcd 0000:00:1d.0: set dev address 2 for port 1 [ 5.037125] ehci_hcd 0000:00:1d.0: LPM: no device attached [ 5.037362] usb 2-1: udev 2, busnum 2, minor = 129 [ 5.037381] usb 2-1: New USB device found, idVendor=8087, idProduct=8002 [ 5.037731] usb 2-1: New USB device strings: Mfr=0, Product=0, SerialNumber=0 [ 5.038197] usb 2-1: usb_probe_device [ 5.038199] usb 2-1: configuration #1 chosen from 1 choice [ 5.038236] usb 2-1: adding 2-1:1.0 (config #1, interface 0) [ 5.038275] hub 2-1:1.0: usb_probe_interface [ 5.038276] hub 2-1:1.0: usb_probe_interface - got id [ 5.038277] hub 2-1:1.0: USB hub found [ 5.038730] hub 2-1:1.0: 8 ports detected [ 5.039075] hub 2-1:1.0: standalone hub [ 5.039076] hub 2-1:1.0: individual port power switching [ 5.039077] hub 2-1:1.0: individual port over-current protection [ 5.039078] hub 2-1:1.0: Single TT [ 5.039079] hub 2-1:1.0: TT requires at most 8 FS bit times (666 ns) [ 5.039081] hub 2-1:1.0: power on to power good time: 0ms [ 5.039353] hub 2-1:1.0: local power source is good [ 5.039355] hub 2-1:1.0: enabling power on all ports [ 5.040377] drivers/usb/core/inode.c: creating file '002' [ 5.040387] hub 1-1:1.0: state 7 ports 6 chg 0060 evt 0000 [ 5.040481] hub 1-1:1.0: port 5, status 0101, change 0000, 12 Mb/s [ 5.051092] hub 1-1:1.0: port 5 not reset yet, waiting 10ms [ 5.113005] usb 1-1.5: new low speed USB device number 3 using ehci_hcd [ 5.124976] hub 1-1:1.0: port 5 not reset yet, waiting 10ms [ 5.140830] usb 2-1: link qh256-0001/ffff88085ec5f480 start 1 [1/0 us] [ 5.202395] usb 1-1.5: skipped 1 descriptor after interface [ 5.202401] usb 1-1.5: skipped 1 descriptor after interface [ 5.202983] usb 1-1.5: default language 0x0409 [ 5.206638] usb 1-1.5: udev 3, busnum 1, minor = 2 [ 5.206643] usb 1-1.5: New USB device found, idVendor=0557, idProduct=2221 [ 5.207008] usb 1-1.5: New USB device strings: Mfr=1, Product=2, SerialNumber=3 [ 5.207649] usb 1-1.5: Product: UC-10KM V1.3.124 [ 5.207994] usb 1-1.5: Manufacturer: ATEN [ 5.208337] usb 1-1.5: SerialNumber: USB Composite device [ 5.208803] usb 1-1.5: usb_probe_device [ 5.208805] usb 1-1.5: configuration #1 chosen from 1 choice [ 5.210258] usb 1-1.5: adding 1-1.5:1.0 (config #1, interface 0) [ 5.211620] usbhid 1-1.5:1.0: usb_probe_interface [ 5.211625] usbhid 1-1.5:1.0: usb_probe_interface - got id [ 5.216588] input: ATEN UC-10KM V1.3.124 as /devices/pci0000:00/0000:00:1a.0/usb1/1-1/1-1.5/1-1.5:1.0/input/input2 [ 5.217237] usb 1-1.5: link qh8-0601/ffff88085ec5f580 start 2 [1/2 us] [ 5.217373] generic-usb 0003:0557:2221.0001: input,hidraw0: USB HID v1.10 Keyboard [ATEN UC-10KM V1.3.124] on usb-0000:00:1a.0-1.5/input0 [ 5.218016] usb 1-1.5: adding 1-1.5:1.1 (config #1, interface 1) [ 5.219260] usbhid 1-1.5:1.1: usb_probe_interface [ 5.219264] usbhid 1-1.5:1.1: usb_probe_interface - got id [ 5.223665] input: ATEN UC-10KM V1.3.124 as /devices/pci0000:00/0000:00:1a.0/usb1/1-1/1-1.5/1-1.5:1.1/input/input3 [ 5.224459] generic-usb 0003:0557:2221.0002: input,hidraw1: USB HID v1.10 Mouse [ATEN UC-10KM V1.3.124] on usb-0000:00:1a.0-1.5/input1 [ 5.225103] drivers/usb/core/inode.c: creating file '003' [ 5.225192] hub 1-1:1.0: port 6, status 0101, change 0000, 12 Mb/s [ 5.235805] hub 1-1:1.0: port 6 not reset yet, waiting 10ms [ 5.297708] usb 1-1.6: new high speed USB device number 4 using ehci_hcd [ 5.308689] hub 1-1:1.0: port 6 not reset yet, waiting 10ms [ 5.382825] usb 1-1.6: udev 4, busnum 1, minor = 3 [ 5.382830] usb 1-1.6: New USB device found, idVendor=0557, idProduct=7000 [ 5.383188] usb 1-1.6: New USB device strings: Mfr=0, Product=0, SerialNumber=0 [ 5.383947] usb 1-1.6: usb_probe_device [ 5.383949] usb 1-1.6: configuration #1 chosen from 1 choice [ 5.384071] usb 1-1.6: adding 1-1.6:1.0 (config #1, interface 0) [ 5.384109] hub 1-1.6:1.0: usb_probe_interface [ 5.384110] hub 1-1.6:1.0: usb_probe_interface - got id [ 5.384112] hub 1-1.6:1.0: USB hub found [ 5.384565] hub 1-1.6:1.0: 4 ports detected [ 5.384908] hub 1-1.6:1.0: standalone hub [ 5.384909] hub 1-1.6:1.0: ganged power switching [ 5.384911] hub 1-1.6:1.0: global over-current protection [ 5.384912] hub 1-1.6:1.0: Single TT [ 5.384913] hub 1-1.6:1.0: TT requires at most 8 FS bit times (666 ns) [ 5.384914] hub 1-1.6:1.0: power on to power good time: 0ms [ 5.385189] hub 1-1.6:1.0: local power source is lost (inactive) [ 5.385190] hub 1-1.6:1.0: no over-current condition exists [ 5.385192] hub 1-1.6:1.0: enabling power on all ports [ 5.385694] drivers/usb/core/inode.c: creating file '004' [ 5.385704] hub 2-1:1.0: state 7 ports 8 chg 0000 evt 0000 [ 5.385705] hub 1-1:1.0: state 7 ports 6 chg 0000 evt 0020 [ 5.485546] hub 1-1.6:1.0: port 1: status 0101 change 0001 [ 5.585151] usb 1-1.6: link qh256-0001/ffff88085ec5f780 start 3 [1/0 us] [ 5.585208] hub 1-1.6:1.0: state 7 ports 4 chg 0002 evt 0000 [ 5.585423] hub 1-1.6:1.0: port 1, status 0101, change 0000, 12 Mb/s [ 5.667139] usb 1-1.6.1: new low speed USB device number 5 using ehci_hcd [ 5.768716] usb 1-1.6.1: skipped 1 descriptor after interface [ 5.768719] usb 1-1.6.1: skipped 1 descriptor after interface [ 5.768721] usb 1-1.6.1: udev 5, busnum 1, minor = 4 [ 5.768723] usb 1-1.6.1: New USB device found, idVendor=0557, idProduct=2419 [ 5.769077] usb 1-1.6.1: New USB device strings: Mfr=0, Product=0, SerialNumber=0 [ 5.769817] usb 1-1.6.1: usb_probe_device [ 5.769819] usb 1-1.6.1: configuration #1 chosen from 1 choice [ 5.769969] usb 1-1.6.1: adding 1-1.6.1:1.0 (config #1, interface 0) [ 5.770010] usbhid 1-1.6.1:1.0: usb_probe_interface [ 5.770011] usbhid 1-1.6.1:1.0: usb_probe_interface - got id [ 5.770567] input: HID 0557:2419 as /devices/pci0000:00/0000:00:1a.0/usb1/1-1/1-1.6/1-1.6.1/1-1.6.1:1.0/input/input4 [ 5.771211] usb 1-1.6.1: link qh8-0601/ffff88085ec5fa80 start 4 [1/2 us] [ 5.771344] generic-usb 0003:0557:2419.0003: input,hidraw2: USB HID v1.00 Keyboard [HID 0557:2419] on usb-0000:00:1a.0-1.6.1/input0 [ 5.771990] usb 1-1.6.1: adding 1-1.6.1:1.1 (config #1, interface 1) [ 5.772046] usbhid 1-1.6.1:1.1: usb_probe_interface [ 5.772048] usbhid 1-1.6.1:1.1: usb_probe_interface - got id [ 5.772848] input: HID 0557:2419 as /devices/pci0000:00/0000:00:1a.0/usb1/1-1/1-1.6/1-1.6.1/1-1.6.1:1.1/input/input5 [ 5.773611] generic-usb 0003:0557:2419.0004: input,hidraw3: USB HID v1.00 Mouse [HID 0557:2419] on usb-0000:00:1a.0-1.6.1/input1 [ 5.774252] drivers/usb/core/inode.c: creating file '005' [ 7.707212] igb: eth0 NIC Link is Up 1000 Mbps Full Duplex, Flow Control: RX [ 7.710307] ADDRCONF(NETDEV_CHANGE): eth0: link becomes ready [ 7.719793] Sending DHCP requests .., OK [ 11.142454] IP-Config: Got DHCP answer from 10.101.0.12, my address is 10.101.0.98 [ 11.187104] IP-Config: Complete: [ 11.187451] device=eth0, addr=10.101.0.98, mask=255.255.255.0, gw=10.101.0.1, [ 11.187990] host=10.101.0.98, domain=cds.ligo-wa.caltech.edu, nis-domain=(none), [ 11.188675] bootserver=10.101.0.12, rootserver=10.101.0.12, rootpath= [ 11.189583] md: Waiting for all devices to be available before autodetect [ 11.189932] md: If you don't use raid, use raid=noautodetect [ 11.190464] md: Autodetecting RAID arrays. [ 11.190810] md: Scanned 0 and added 0 devices. [ 11.191154] md: autorun ... [ 11.191501] md: ... autorun DONE. [ 11.195314] VFS: Mounted root (nfs filesystem) readonly on device 0:14. [ 11.196752] Freeing unused kernel memory: 616k freed [ 11.197195] Write protecting the kernel read-only data: 10240k [ 11.199409] Freeing unused kernel memory: 700k freed [ 11.204076] Freeing unused kernel memory: 1716k freed [ 11.323297] consoletype used greatest stack depth: 4192 bytes left [ 11.330539] stty used greatest stack depth: 4088 bytes left [ 11.513436] write_root_link used greatest stack depth: 3776 bytes left [ 11.578457] udev: starting version 149 [ 11.578492] udevd (1669): /proc/1669/oom_adj is deprecated, please use /proc/1669/oom_score_adj instead. [ 18.465910] eth0: no IPv6 routers present [ 23.851048] igb 0000:1a:00.1: changing MTU from 1500 to 9000 [ 23.965903] ADDRCONF(NETDEV_UP): eth1: link is not ready [ 23.990636] Symmetricom/Spectracom GPS card not found [ 24.213468] gpstime_sysfs_gps_offset_store success - new value = -315964782 [ 24.252072] Open-MX 1.5.4 initializing... [ 24.252083] Open-MX: attaching interfaces listed in 'eth1'... [ 24.252085] Open-MX: Attaching Ethernet interface 'eth1' as #0, MTU=9000 [ 24.252087] Open-MX: Interface 'eth1' is PCI device '0000:1a:00.1' managed by driver 'igb' [ 24.252090] Open-MX: attached 1 interfaces [ 24.252125] Open-MX initialized [ 55.956520] dis_kosif: Poll provider thread started [ 56.018443] dis_intel_dma: module license 'Proprietary' taints kernel. [ 56.018448] Disabling lock debugging due to kernel taint [ 56.018719] dis-intel-dma: Driver registered successfully [ 56.021764] dis-ix-dma: Probing device 111d:8091 [0880] [ 56.021785] dis_ix_dma 0000:03:00.2: PCI INT B -> GSI 37 (level, low) -> IRQ 37 [ 56.021791] Found write combining in PAT1 [ 56.021796] dis_ix_dma 0000:03:00.2: setting latency timer to 64 [ 56.021799] dis-ix-dma: Device dis-ix-dma0 supports DMA with 64-bit addressing [ 56.021863] dis-ix-dma: dis-ix-dma0 PCI BAR0 ioremap success with phys addr: f8800000, virt addr: ffffc90014048000, len: 1000 [ 56.022041] dis_ix_dma 0000:03:00.2: irq 106 for MSI/MSI-X [ 56.022077] dis-ix-dma: dis-ix-dma0: Initialized DMA device successfully [ 56.022257] dis-ix-dma: Probing device 111d:8091 [0880] [ 56.022360] dis_ix_dma 0000:0c:00.2: PCI INT B -> GSI 46 (level, low) -> IRQ 46 [ 56.022498] Found write combining in PAT1 [ 56.022590] dis_ix_dma 0000:0c:00.2: setting latency timer to 64 [ 56.022637] dis-ix-dma: Device dis-ix-dma1 supports DMA with 64-bit addressing [ 56.022650] dis-ix-dma: dis-ix-dma1 PCI BAR0 ioremap success with phys addr: f0800000, virt addr: ffffc90013f86000, len: 1000 [ 56.025636] dis_ix_dma 0000:0c:00.2: irq 107 for MSI/MSI-X [ 56.026180] dis-ix-dma: dis-ix-dma1: Initialized DMA device successfully [ 56.026207] dis-ix-dma: Probing device 111d:8091 [0880] [ 56.026308] dis_ix_dma 0000:15:00.2: PCI INT B -> GSI 46 (level, low) -> IRQ 46 [ 56.026447] Found write combining in PAT1 [ 56.026540] dis_ix_dma 0000:15:00.2: setting latency timer to 64 [ 56.026587] dis-ix-dma: Device dis-ix-dma2 supports DMA with 64-bit addressing [ 56.026598] dis-ix-dma: dis-ix-dma2 PCI BAR0 ioremap success with phys addr: e8800000, virt addr: ffffc90013f88000, len: 1000 [ 56.029617] dis_ix_dma 0000:15:00.2: irq 108 for MSI/MSI-X [ 56.030165] dis-ix-dma: dis-ix-dma2: Initialized DMA device successfully [ 56.030184] dis-ix-dma: Driver registered successfully [ 56.032688] dis-ix-ntb: Found write combining in PAT1 [ 56.032814] dis-ix-ntb: MCAST pool: Wanted 64 MB requested 64 MB, got: 64 MB, usable 64 MB, alignment 2^24 after 1 attempt(s) [ 56.033076] dis-ix-ntb: PIO pool: requested 160 MB, got 164 MB, largest contiguous: 164 MB, fragmented: No [ 56.033111] dis-ix-ntb: Probing device 03:00.1 0680: 111d:8091 [ 56.033127] dis_ix_ntb 0000:03:00.1: PCI INT A -> GSI 34 (level, low) -> IRQ 34 [ 56.033134] Found write combining in PAT1 [ 56.033141] dis-ix-ntb: Completion Timeout is non-fatal in device 8086:6f06 [ 56.033146] dis_ix_ntb 0000:03:00.1: setting latency timer to 64 [ 56.033150] dis-ix-ntb: Device 03:00.1 supports DMA with 64-bit addressing [ 56.033197] dis-ix-ntb: 03:00.1 PCI BAR0 ioremap_nocache/wc success with phys addr: f8801000, virt addr: ffffc90013f8a000, len: 1000 [ 56.037210] dis-ix-ntb: 03:00.1 PCI BAR4 ioremap_nocache/wc success with phys addr: f4000000, virt addr: ffffc90014080000, len: 4000000 [ 56.037713] dis-ix-ntb: 03:00.1 PCI BAR5 ioremap_nocache/wc success with phys addr: f8000000, virt addr: ffffc90018100000, len: 800000 [ 56.037725] dis-ix-ntb: dis-ix-ntb0: Detected port configuration x8 [ 56.037726] dis-ix-ntb: dis-ix-ntb0: Using 2 DMA channels [ 56.037728] dis-ix-ntb: dis-ix-ntb0: Internal DMA enabled - Global DMA enabled [ 56.037730] dis-ix-ntb: dis-ix-ntb0: IOMMU support not present [ 56.037745] dis-ix-ntb: dis-ix-ntb0: Found NTB device on port 0 [ 56.039022] dis-ix-ntb: Local adapter dis-ix-ntb0 serial number is IXH611-CE-002365 [ 56.039028] dis-ix-ntb: Enabling DMA on port 8 [ 56.089058] dis-ix-ntb: Number of images in the EEPROM: 3 [ 56.089327] dis-ix-ntb: dis-ix-ntb0: Read requester ID is 00:02.2 [ 56.089542] dis_ix_ntb 0000:03:00.1: irq 109 for MSI/MSI-X [ 56.089569] dis-ix-ntb: dis-ix-ntb0: Initialized NTB successfully [ 56.089676] dis-ix-ntb: Probing device 0c:00.1 0680: 111d:8091 [ 56.089775] dis_ix_ntb 0000:0c:00.1: PCI INT A -> GSI 45 (level, low) -> IRQ 45 [ 56.089914] Found write combining in PAT1 [ 56.090746] dis-ix-ntb: Completion Timeout is non-fatal in device 8086:6f08 [ 56.090839] dis_ix_ntb 0000:0c:00.1: setting latency timer to 64 [ 56.090887] dis-ix-ntb: Device 0c:00.1 supports DMA with 64-bit addressing [ 56.090903] dis-ix-ntb: 0c:00.1 PCI BAR0 ioremap_nocache/wc success with phys addr: f0801000, virt addr: ffffc90013f8c000, len: 1000 [ 56.094890] dis-ix-ntb: 0c:00.1 PCI BAR4 ioremap_nocache/wc success with phys addr: ec000000, virt addr: ffffc90018980000, len: 4000000 [ 56.095398] dis-ix-ntb: 0c:00.1 PCI BAR5 ioremap_nocache/wc success with phys addr: f0000000, virt addr: ffffc9001ca00000, len: 800000 [ 56.095676] dis-ix-ntb: dis-ix-ntb1: Detected port configuration x8 [ 56.095678] dis-ix-ntb: dis-ix-ntb1: Using 2 DMA channels [ 56.095679] dis-ix-ntb: dis-ix-ntb1: Internal DMA enabled - Global DMA enabled [ 56.095681] dis-ix-ntb: dis-ix-ntb1: IOMMU support not present [ 56.096053] dis-ix-ntb: dis-ix-ntb1: Found NTB device on port 0 [ 56.125941] dis-ix-ntb: Local adapter dis-ix-ntb1 serial number is IXH611-CE-002344 [ 56.126035] dis-ix-ntb: Enabling DMA on port 8 [ 56.177052] dis-ix-ntb: Number of images in the EEPROM: 3 [ 56.180649] dis-ix-ntb: dis-ix-ntb1: Read requester ID is 00:03.0 [ 56.183033] dis_ix_ntb 0000:0c:00.1: irq 110 for MSI/MSI-X [ 56.183502] dis-ix-ntb: dis-ix-ntb1: Initialized NTB successfully [ 56.183607] dis-ix-ntb: Probing device 15:00.1 0680: 111d:8091 [ 56.183706] dis_ix_ntb 0000:15:00.1: PCI INT A -> GSI 44 (level, low) -> IRQ 44 [ 56.183849] Found write combining in PAT1 [ 56.184682] dis-ix-ntb: Completion Timeout is non-fatal in device 8086:6f0a [ 56.184776] dis_ix_ntb 0000:15:00.1: setting latency timer to 64 [ 56.184824] dis-ix-ntb: Device 15:00.1 supports DMA with 64-bit addressing [ 56.184841] dis-ix-ntb: 15:00.1 PCI BAR0 ioremap_nocache/wc success with phys addr: e8801000, virt addr: ffffc90013f8e000, len: 1000 [ 56.188850] dis-ix-ntb: 15:00.1 PCI BAR4 ioremap_nocache/wc success with phys addr: e4000000, virt addr: ffffc9001d280000, len: 4000000 [ 56.189353] dis-ix-ntb: 15:00.1 PCI BAR5 ioremap_nocache/wc success with phys addr: e8000000, virt addr: ffffc90021300000, len: 800000 [ 56.189632] dis-ix-ntb: dis-ix-ntb2: Detected port configuration x8 [ 56.189634] dis-ix-ntb: dis-ix-ntb2: Using 2 DMA channels [ 56.189635] dis-ix-ntb: dis-ix-ntb2: Internal DMA enabled - Global DMA enabled [ 56.189637] dis-ix-ntb: dis-ix-ntb2: IOMMU support not present [ 56.190014] dis-ix-ntb: dis-ix-ntb2: Found NTB device on port 0 [ 56.220130] dis-ix-ntb: Local adapter dis-ix-ntb2 serial number is IXH611-CE-002348 [ 56.220224] dis-ix-ntb: Enabling DMA on port 8 [ 56.270922] dis-ix-ntb: Number of images in the EEPROM: 3 [ 56.274530] dis-ix-ntb: dis-ix-ntb2: Read requester ID is 00:03.2 [ 56.276932] dis_ix_ntb 0000:15:00.1: irq 111 for MSI/MSI-X [ 56.277404] dis-ix-ntb: dis-ix-ntb2: Initialized NTB successfully [ 56.277448] dis-ix-ntb: Driver registered successfully [ 56.341529] IXH Dolphin Driver : dis_irm.conf: Disabling link watchdog [ 56.341531] IXH Dolphin Driver : dis_irm.conf: Enabling resource outtage notes [ 56.341533] IXH Dolphin Driver : dis_irm.conf: Setting driver page size to 1048576 bytes [ 56.341535] IXH Dolphin Driver : dis_irm.conf: Page Size is 1024K bytes [ 56.341537] IXH Dolphin Driver : dis_irm.conf: Force link retraining property is disabled [ 56.341538] IXH Dolphin Driver : dis_irm.conf: Min accepted link speed is set to Gen1 [ 56.341540] IXH Dolphin Driver : dis_irm.conf: Session probing disabled while heartbeat is ok [ 56.341541] IXH Dolphin Driver : dis_irm.conf: IOMMU usage disabled [ 56.341543] IXH Dolphin Driver : Interrupt poll mode 2 (On: 1000, Off: 100) requested by default [ 56.341545] IXH Dolphin Driver : DMA poll mode 2 (On: 1000, Off: 100) requested by default [ 56.341548] IXH Dolphin Driver : MTRR not used [ 56.341549] IXH Dolphin Driver : 3 supported IX adapter card found on the system [ 56.341552] IXH Dolphin Driver : Found write combining in PAT1 [ 56.341553] IXH Dolphin Driver : version Dolphin IRM (GX) 5.7.0 Aug 8th 2018 (rev 8a53628) initializing [ 56.341555] IXH Dolphin Driver : 64 bit mode Compiled Thu Oct 11 15:27:36 UTC 2018 [ 56.341557] IXH Dolphin Driver : Session heartbeats disabled [ 56.341558] IXH Dolphin Driver : Link Watchdog disabled [ 56.341568] IXH Adapter 0 : Set min link width to x8 [ 56.341569] IXH Adapter 0 : Set min link speed to Gen1 [ 56.341571] IXH Instance 0 : Awaiting configuration (Serial number is 002365) [ 56.341573] IXH Adapter 1 : Set min link width to x8 [ 56.341575] IXH Adapter 1 : Set min link speed to Gen1 [ 56.341577] IXH Instance 1 : Awaiting configuration (Serial number is 002344) [ 56.341578] IXH Adapter 2 : Set min link width to x8 [ 56.341580] IXH Adapter 2 : Set min link speed to Gen1 [ 56.341581] IXH Instance 2 : Awaiting configuration (Serial number is 002348) [ 56.341583] IXH Adapter 100 : gen_init_device_pre initializing [ 56.341586] Adapter 100: virtadap_initialize_device_pre disable_automatic_rebuild = 0, task = ffff88085d7a50c0 [ 56.341588] IXH Dolphin Driver : successfully registered. Major number = 247 [ 63.760477] IXH Adapter 100 : Configured Adapter to nodeId=96 (GX nodeId=24) [ 63.761106] IXH Adapter 0 : Driver attaching device 0 [ 63.761114] IXH Adapter 0 : Local adapter type: IXH611 [ 63.761117] IXH Adapter 0 : Number of local link ports enabled: 1 [ 63.761126] dis-ix-ntb: dis-ix-ntb0: System DMA disabled [ 63.761131] dis-ix-ntb: dis-ix-ntb0: SystemId set to 24, topology TOPOLOGY_NOT_DETERMINED [ 63.761142] IXH Adapter 0 : IDT Logan adapter chip revision: ZC [ 63.761146] IXH Adapter 0 : EEPROM version NTB mode: 8 [ 63.761150] IXH Adapter 0 : Adapter serial number: IXH611-CE-002365 [ 63.761155] IXH Adapter 0 : PCIe slot - x8, (gen2) 5 GT/s [ 63.761158] IXH Adapter 0 : BAR2 size: 256 MB [ 63.761161] IXH Adapter 0 : BAR4 size: 64 MB [ 63.761164] IXH Adapter 0 : BAR5 size: 8 MB [ 63.761167] IXH Adapter 0 : Prefetch memory BAR2 size: 256 MB [ 63.761173] IXH Adapter 0 : Logan chip temperature = 62 C [ 63.761184] IXH Adapter 0 : EEPROM dip-switch swmode[3:0]: 0010 [ 63.761187] IXH Adapter 0 : Number of images in the EEPROM: 3 [ 63.761192] IXH Adapter 0 : Clock mode slot (P0): Local [ 63.761195] IXH Adapter 0 : Clock mode link (P8): Local [ 63.761200] IXH Adapter 0 : GPIO data: 0x42 [ 63.761203] IXH Adapter 0 : Multicast group size: 16 MB [ 63.761206] IXH Adapter 0 : Max payload size (MPS): 256 Bytes [ 63.761212] IXH Adapter 0 : Link[0] config: LINK_CONFIG_NTB [ 63.761218] IXH Adapter 0 : Adapter link 0 link width: x8 [ 63.761221] IXH Adapter 0 : Cable link 0 PCIe link - x8, (gen2) 5 GT/s [ 63.761225] IXH Adapter 0 : NodeId is 96 - Serial no : 002365 [ 63.761321] IXH Dolphin Driver : Using copy function sciMemCopy_No_FPU() [ 63.762612] IXH Adapter 101 : Configured Adapter to nodeId=100 (GX nodeId=25) [ 63.763042] IXH Adapter 1 : Driver attaching device 1 [ 63.763136] IXH Adapter 1 : Local adapter type: IXH611 [ 63.763138] IXH Adapter 1 : Number of local link ports enabled: 1 [ 63.763144] dis-ix-ntb: dis-ix-ntb1: System DMA disabled [ 63.763146] dis-ix-ntb: dis-ix-ntb1: SystemId set to 25, topology TOPOLOGY_NOT_DETERMINED [ 63.763198] IXH Adapter 1 : IDT Logan adapter chip revision: ZC [ 63.763248] IXH Adapter 1 : EEPROM version NTB mode: 8 [ 63.763250] IXH Adapter 1 : Adapter serial number: IXH611-CE-002344 [ 63.763296] IXH Adapter 1 : PCIe slot - x1, (gen2) 5 GT/s [ 63.763298] IXH Adapter 1 : BAR2 size: 256 MB [ 63.763300] IXH Adapter 1 : BAR4 size: 64 MB [ 63.763301] IXH Adapter 1 : BAR5 size: 8 MB [ 63.763303] IXH Adapter 1 : Prefetch memory BAR2 size: 256 MB [ 63.763351] IXH Adapter 1 : Logan chip temperature = 81 C [ 63.763493] IXH Adapter 1 : EEPROM dip-switch swmode[3:0]: 0010 [ 63.763494] IXH Adapter 1 : Number of images in the EEPROM: 3 [ 63.763542] IXH Adapter 1 : Clock mode slot (P0): Local [ 63.763543] IXH Adapter 1 : Clock mode link (P8): Local [ 63.763592] IXH Adapter 1 : GPIO data: 0x42 [ 63.763593] IXH Adapter 1 : Multicast group size: 16 MB [ 63.763594] IXH Adapter 1 : Max payload size (MPS): 256 Bytes [ 63.763643] IXH Adapter 1 : Link[0] config: LINK_CONFIG_NTB [ 63.763691] IXH Adapter 1 : Adapter link 0 link width: x8 [ 63.763693] IXH Adapter 1 : Cable link 0 PCIe link - x8, (gen2) 5 GT/s [ 63.763694] IXH Adapter 1 : NodeId is 100 - Serial no : 002344 [ 63.766016] IXH Adapter 102 : Configured Adapter to nodeId=104 (GX nodeId=26) [ 63.767094] IXH Adapter 2 : Driver attaching device 2 [ 63.767206] IXH Adapter 2 : Local adapter type: IXH611 [ 63.767207] IXH Adapter 2 : Number of local link ports enabled: 1 [ 63.767212] dis-ix-ntb: dis-ix-ntb2: System DMA disabled [ 63.767214] dis-ix-ntb: dis-ix-ntb2: SystemId set to 26, topology TOPOLOGY_NOT_DETERMINED [ 63.767216] IXH Adapter 2 : IDT Logan adapter chip revision: ZC [ 63.767264] IXH Adapter 2 : EEPROM version NTB mode: 8 [ 63.767266] IXH Adapter 2 : Adapter serial number: IXH611-CE-002348 [ 63.767313] IXH Adapter 2 : PCIe slot - x1, (gen2) 5 GT/s [ 63.767315] IXH Adapter 2 : BAR2 size: 256 MB [ 63.767316] IXH Adapter 2 : BAR4 size: 64 MB [ 63.767318] IXH Adapter 2 : BAR5 size: 8 MB [ 63.767319] IXH Adapter 2 : Prefetch memory BAR2 size: 256 MB [ 63.767368] IXH Adapter 2 : Logan chip temperature = 89 C [ 63.767511] IXH Adapter 2 : EEPROM dip-switch swmode[3:0]: 0010 [ 63.767512] IXH Adapter 2 : Number of images in the EEPROM: 3 [ 63.767560] IXH Adapter 2 : Clock mode slot (P0): Local [ 63.767562] IXH Adapter 2 : Clock mode link (P8): Local [ 63.767610] IXH Adapter 2 : GPIO data: 0x42 [ 63.767612] IXH Adapter 2 : Multicast group size: 16 MB [ 63.767613] IXH Adapter 2 : Max payload size (MPS): 256 Bytes [ 63.767662] IXH Adapter 2 : Link[0] config: LINK_CONFIG_NTB [ 63.767711] IXH Adapter 2 : Adapter link 0 link width: x8 [ 63.767712] IXH Adapter 2 : Cable link 0 PCIe link - x8, (gen2) 5 GT/s [ 63.767714] IXH Adapter 2 : NodeId is 104 - Serial no : 002348 [ 63.768237] IXH Adapter 0 : Set reachable remote node list. [ 63.768262] IXH Adapter 1 : Set reachable remote node list. [ 63.768297] IXH Adapter 2 : Set reachable remote node list. [ 63.865923] dis-ix-ntb: dis-ix-ntb0: Detected IXS600 (601) switch, TOP, port 5, global port 37 [ 63.866417] dis-ix-dma: Using NT interrupt [ 63.866423] IXH Adapter 0 : Topology is Switch - (autodetect) [ 63.866443] IXH Adapter 0 : Local adapter is connected to IXS600 switch, TOP, port 5 [ 63.866448] IXH Adapter 0 : Link 0 is operational - Link width: x8 - PCIe Gen 2 -- Downtime: 0 sec [ 63.868254] dis-ix-ntb: dis-ix-ntb1: Detected IXS600 (601) switch, TOP, port 7, global port 55 [ 63.869936] IXH Adapter 1 : Topology is Switch - (autodetect) [ 63.870177] IXH Adapter 1 : Local adapter is connected to IXS600 switch, TOP, port 7 [ 63.870226] IXH Adapter 1 : Link 0 is operational - Link width: x8 - PCIe Gen 2 -- Downtime: 0 sec [ 84.861593] IXH Adapter 2 : Configured Adapter to nodeId=104 (GX nodeId=26) [ 84.861805] IXH Adapter 2 : Adapter terminated [ 84.862017] IXH Adapter 2 : Driver attaching device 2 [ 84.862113] IXH Adapter 2 : Local adapter type: IXH611 [ 84.862115] IXH Adapter 2 : Number of local link ports enabled: 1 [ 84.862120] dis-ix-ntb: dis-ix-ntb2: System DMA disabled [ 84.862122] dis-ix-ntb: dis-ix-ntb2: SystemId set to 26, topology TOPOLOGY_SWITCH [ 84.862124] IXH Adapter 2 : IDT Logan adapter chip revision: ZC [ 84.862171] IXH Adapter 2 : EEPROM version NTB mode: 8 [ 84.862173] IXH Adapter 2 : Adapter serial number: IXH611-CE-002348 [ 84.862220] IXH Adapter 2 : PCIe slot - x1, (gen2) 5 GT/s [ 84.862222] IXH Adapter 2 : BAR2 size: 256 MB [ 84.862223] IXH Adapter 2 : BAR4 size: 64 MB [ 84.862225] IXH Adapter 2 : BAR5 size: 8 MB [ 84.862226] IXH Adapter 2 : Prefetch memory BAR2 size: 256 MB [ 84.862275] IXH Adapter 2 : Logan chip temperature = 89 C [ 84.862418] IXH Adapter 2 : EEPROM dip-switch swmode[3:0]: 0010 [ 84.862419] IXH Adapter 2 : Number of images in the EEPROM: 3 [ 84.862468] IXH Adapter 2 : Clock mode slot (P0): Local [ 84.862469] IXH Adapter 2 : Clock mode link (P8): Local [ 84.862518] IXH Adapter 2 : GPIO data: 0x42 [ 84.862519] IXH Adapter 2 : Multicast group size: 16 MB [ 84.862520] IXH Adapter 2 : Max payload size (MPS): 256 Bytes [ 84.862569] IXH Adapter 2 : Link[0] config: LINK_CONFIG_NTB [ 84.862618] IXH Adapter 2 : Adapter link 0 link width: x8 [ 84.862619] IXH Adapter 2 : Cable link 0 PCIe link - x8, (gen2) 5 GT/s [ 84.862621] IXH Adapter 2 : NodeId is 104 - Serial no : 002348 COMMAND: /usr/sbin/lspci 00:00.0 Host bridge: Intel Corporation Device 6f00 (rev 01) 00:01.0 PCI bridge: Intel Corporation Device 6f02 (rev 01) 00:02.0 PCI bridge: Intel Corporation Device 6f04 (rev 01) 00:02.2 PCI bridge: Intel Corporation Device 6f06 (rev 01) 00:03.0 PCI bridge: Intel Corporation Device 6f08 (rev 01) 00:03.2 PCI bridge: Intel Corporation Device 6f0a (rev 01) 00:04.0 System peripheral: Intel Corporation Device 6f20 (rev 01) 00:04.1 System peripheral: Intel Corporation Device 6f21 (rev 01) 00:04.2 System peripheral: Intel Corporation Device 6f22 (rev 01) 00:04.3 System peripheral: Intel Corporation Device 6f23 (rev 01) 00:04.4 System peripheral: Intel Corporation Device 6f24 (rev 01) 00:04.5 System peripheral: Intel Corporation Device 6f25 (rev 01) 00:04.6 System peripheral: Intel Corporation Device 6f26 (rev 01) 00:04.7 System peripheral: Intel Corporation Device 6f27 (rev 01) 00:05.0 System peripheral: Intel Corporation Device 6f28 (rev 01) 00:05.1 System peripheral: Intel Corporation Device 6f29 (rev 01) 00:05.2 System peripheral: Intel Corporation Device 6f2a (rev 01) 00:05.4 PIC: Intel Corporation Device 6f2c (rev 01) 00:11.0 Class ff00: Intel Corporation Device 8d7c (rev 05) 00:11.4 SATA controller: Intel Corporation Device 8d62 (rev 05) 00:14.0 USB Controller: Intel Corporation Device 8d31 (rev 05) 00:16.0 Communication controller: Intel Corporation Device 8d3a (rev 05) 00:16.1 Communication controller: Intel Corporation Device 8d3b (rev 05) 00:1a.0 USB Controller: Intel Corporation Device 8d2d (rev 05) 00:1c.0 PCI bridge: Intel Corporation Device 8d10 (rev d5) 00:1c.2 PCI bridge: Intel Corporation Device 8d14 (rev d5) 00:1c.4 PCI bridge: Intel Corporation Device 8d18 (rev d5) 00:1d.0 USB Controller: Intel Corporation Device 8d26 (rev 05) 00:1f.0 ISA bridge: Intel Corporation Device 8d44 (rev 05) 00:1f.2 SATA controller: Intel Corporation Device 8d02 (rev 05) 00:1f.3 SMBus: Intel Corporation Device 8d22 (rev 05) 03:00.0 PCI bridge: Integrated Device Technology, Inc. Device 8091 (rev 02) 03:00.1 Bridge: Integrated Device Technology, Inc. Device 8091 (rev 02) 03:00.2 System peripheral: Integrated Device Technology, Inc. Device 8091 (rev 02) 05:00.0 PCI bridge: PLX Technology, Inc. Device 8608 (rev ba) 06:01.0 PCI bridge: PLX Technology, Inc. Device 8608 (rev ba) 07:00.0 PCI bridge: PLX Technology, Inc. Device 8606 (rev ba) 08:01.0 PCI bridge: PLX Technology, Inc. Device 8606 (rev ba) 08:05.0 PCI bridge: PLX Technology, Inc. Device 8606 (rev ba) 08:07.0 PCI bridge: PLX Technology, Inc. Device 8606 (rev ba) 08:09.0 PCI bridge: PLX Technology, Inc. Device 8606 (rev ba) 0c:00.0 PCI bridge: Integrated Device Technology, Inc. Device 8091 (rev 02) 0c:00.1 Bridge: Integrated Device Technology, Inc. Device 8091 (rev 02) 0c:00.2 System peripheral: Integrated Device Technology, Inc. Device 8091 (rev 02) 0e:00.0 PCI bridge: PLX Technology, Inc. Device 8608 (rev ba) 0f:01.0 PCI bridge: PLX Technology, Inc. Device 8608 (rev ba) 10:00.0 PCI bridge: PLX Technology, Inc. Device 8606 (rev ba) 11:01.0 PCI bridge: PLX Technology, Inc. Device 8606 (rev ba) 11:05.0 PCI bridge: PLX Technology, Inc. Device 8606 (rev ba) 11:07.0 PCI bridge: PLX Technology, Inc. Device 8606 (rev ba) 11:09.0 PCI bridge: PLX Technology, Inc. Device 8606 (rev ba) 15:00.0 PCI bridge: Integrated Device Technology, Inc. Device 8091 (rev 02) 15:00.1 Bridge: Integrated Device Technology, Inc. Device 8091 (rev 02) 15:00.2 System peripheral: Integrated Device Technology, Inc. Device 8091 (rev 02) 18:00.0 PCI bridge: ASPEED Technology, Inc. Device 1150 (rev 03) 19:00.0 VGA compatible controller: ASPEED Technology, Inc. ASPEED Graphics Family (rev 30) 1a:00.0 Ethernet controller: Intel Corporation Device 1521 (rev 01) 1a:00.1 Ethernet controller: Intel Corporation Device 1521 (rev 01) ff:0b.0 System peripheral: Intel Corporation Device 6f81 (rev 01) ff:0b.1 Performance counters: Intel Corporation Device 6f36 (rev 01) ff:0b.2 Performance counters: Intel Corporation Device 6f37 (rev 01) ff:0b.3 System peripheral: Intel Corporation Device 6f76 (rev 01) ff:0c.0 System peripheral: Intel Corporation Device 6fe0 (rev 01) ff:0c.1 System peripheral: Intel Corporation Device 6fe1 (rev 01) ff:0c.2 System peripheral: Intel Corporation Device 6fe2 (rev 01) ff:0c.3 System peripheral: Intel Corporation Device 6fe3 (rev 01) ff:0c.4 System peripheral: Intel Corporation Device 6fe4 (rev 01) ff:0c.5 System peripheral: Intel Corporation Device 6fe5 (rev 01) ff:0c.6 System peripheral: Intel Corporation Device 6fe6 (rev 01) ff:0c.7 System peripheral: Intel Corporation Device 6fe7 (rev 01) ff:0d.0 System peripheral: Intel Corporation Device 6fe8 (rev 01) ff:0d.1 System peripheral: Intel Corporation Device 6fe9 (rev 01) ff:0f.0 System peripheral: Intel Corporation Device 6ff8 (rev 01) ff:0f.1 System peripheral: Intel Corporation Device 6ff9 (rev 01) ff:0f.4 System peripheral: Intel Corporation Device 6ffc (rev 01) ff:0f.5 System peripheral: Intel Corporation Device 6ffd (rev 01) ff:0f.6 System peripheral: Intel Corporation Device 6ffe (rev 01) ff:10.0 System peripheral: Intel Corporation Device 6f1d (rev 01) ff:10.1 Performance counters: Intel Corporation Device 6f34 (rev 01) ff:10.5 System peripheral: Intel Corporation Device 6f1e (rev 01) ff:10.6 Performance counters: Intel Corporation Device 6f7d (rev 01) ff:10.7 System peripheral: Intel Corporation Device 6f1f (rev 01) ff:12.0 System peripheral: Intel Corporation Device 6fa0 (rev 01) ff:12.1 Performance counters: Intel Corporation Device 6f30 (rev 01) ff:13.0 System peripheral: Intel Corporation Device 6fa8 (rev 01) ff:13.1 System peripheral: Intel Corporation Device 6f71 (rev 01) ff:13.2 System peripheral: Intel Corporation Device 6faa (rev 01) ff:13.3 System peripheral: Intel Corporation Device 6fab (rev 01) ff:13.4 System peripheral: Intel Corporation Device 6fac (rev 01) ff:13.5 System peripheral: Intel Corporation Device 6fad (rev 01) ff:13.6 System peripheral: Intel Corporation Device 6fae (rev 01) ff:13.7 System peripheral: Intel Corporation Device 6faf (rev 01) ff:14.0 System peripheral: Intel Corporation Device 6fb0 (rev 01) ff:14.1 System peripheral: Intel Corporation Device 6fb1 (rev 01) ff:14.2 System peripheral: Intel Corporation Device 6fb2 (rev 01) ff:14.3 System peripheral: Intel Corporation Device 6fb3 (rev 01) ff:14.4 System peripheral: Intel Corporation Device 6fbc (rev 01) ff:14.5 System peripheral: Intel Corporation Device 6fbd (rev 01) ff:14.6 System peripheral: Intel Corporation Device 6fbe (rev 01) ff:14.7 System peripheral: Intel Corporation Device 6fbf (rev 01) ff:15.0 System peripheral: Intel Corporation Device 6fb4 (rev 01) ff:15.1 System peripheral: Intel Corporation Device 6fb5 (rev 01) ff:15.2 System peripheral: Intel Corporation Device 6fb6 (rev 01) ff:15.3 System peripheral: Intel Corporation Device 6fb7 (rev 01) ff:16.0 System peripheral: Intel Corporation Device 6f68 (rev 01) ff:16.6 System peripheral: Intel Corporation Device 6f6e (rev 01) ff:16.7 System peripheral: Intel Corporation Device 6f6f (rev 01) ff:17.0 System peripheral: Intel Corporation Device 6fd0 (rev 01) ff:17.4 System peripheral: Intel Corporation Device 6fb8 (rev 01) ff:17.5 System peripheral: Intel Corporation Device 6fb9 (rev 01) ff:17.6 System peripheral: Intel Corporation Device 6fba (rev 01) ff:17.7 System peripheral: Intel Corporation Device 6fbb (rev 01) ff:1e.0 System peripheral: Intel Corporation Device 6f98 (rev 01) ff:1e.1 System peripheral: Intel Corporation Device 6f99 (rev 01) ff:1e.2 System peripheral: Intel Corporation Device 6f9a (rev 01) ff:1e.3 System peripheral: Intel Corporation Device 6fc0 (rev 01) ff:1e.4 System peripheral: Intel Corporation Device 6f9c (rev 01) ff:1f.0 System peripheral: Intel Corporation Device 6f88 (rev 01) ff:1f.2 System peripheral: Intel Corporation Device 6f8a (rev 01) COMMAND: /usr/sbin/lspci -vt -+-[0000:ff]-+-0b.0 Intel Corporation Device 6f81 | +-0b.1 Intel Corporation Device 6f36 | +-0b.2 Intel Corporation Device 6f37 | +-0b.3 Intel Corporation Device 6f76 | +-0c.0 Intel Corporation Device 6fe0 | +-0c.1 Intel Corporation Device 6fe1 | +-0c.2 Intel Corporation Device 6fe2 | +-0c.3 Intel Corporation Device 6fe3 | +-0c.4 Intel Corporation Device 6fe4 | +-0c.5 Intel Corporation Device 6fe5 | +-0c.6 Intel Corporation Device 6fe6 | +-0c.7 Intel Corporation Device 6fe7 | +-0d.0 Intel Corporation Device 6fe8 | +-0d.1 Intel Corporation Device 6fe9 | +-0f.0 Intel Corporation Device 6ff8 | +-0f.1 Intel Corporation Device 6ff9 | +-0f.4 Intel Corporation Device 6ffc | +-0f.5 Intel Corporation Device 6ffd | +-0f.6 Intel Corporation Device 6ffe | +-10.0 Intel Corporation Device 6f1d | +-10.1 Intel Corporation Device 6f34 | +-10.5 Intel Corporation Device 6f1e | +-10.6 Intel Corporation Device 6f7d | +-10.7 Intel Corporation Device 6f1f | +-12.0 Intel Corporation Device 6fa0 | +-12.1 Intel Corporation Device 6f30 | +-13.0 Intel Corporation Device 6fa8 | +-13.1 Intel Corporation Device 6f71 | +-13.2 Intel Corporation Device 6faa | +-13.3 Intel Corporation Device 6fab | +-13.4 Intel Corporation Device 6fac | +-13.5 Intel Corporation Device 6fad | +-13.6 Intel Corporation Device 6fae | +-13.7 Intel Corporation Device 6faf | +-14.0 Intel Corporation Device 6fb0 | +-14.1 Intel Corporation Device 6fb1 | +-14.2 Intel Corporation Device 6fb2 | +-14.3 Intel Corporation Device 6fb3 | +-14.4 Intel Corporation Device 6fbc | +-14.5 Intel Corporation Device 6fbd | +-14.6 Intel Corporation Device 6fbe | +-14.7 Intel Corporation Device 6fbf | +-15.0 Intel Corporation Device 6fb4 | +-15.1 Intel Corporation Device 6fb5 | +-15.2 Intel Corporation Device 6fb6 | +-15.3 Intel Corporation Device 6fb7 | +-16.0 Intel Corporation Device 6f68 | +-16.6 Intel Corporation Device 6f6e | +-16.7 Intel Corporation Device 6f6f | +-17.0 Intel Corporation Device 6fd0 | +-17.4 Intel Corporation Device 6fb8 | +-17.5 Intel Corporation Device 6fb9 | +-17.6 Intel Corporation Device 6fba | +-17.7 Intel Corporation Device 6fbb | +-1e.0 Intel Corporation Device 6f98 | +-1e.1 Intel Corporation Device 6f99 | +-1e.2 Intel Corporation Device 6f9a | +-1e.3 Intel Corporation Device 6fc0 | +-1e.4 Intel Corporation Device 6f9c | +-1f.0 Intel Corporation Device 6f88 | \-1f.2 Intel Corporation Device 6f8a \-[0000:00]-+-00.0 Intel Corporation Device 6f00 +-01.0-[01]-- +-02.0-[02]-- +-02.2-[03-04]--+-00.0-[04]-- | +-00.1 Integrated Device Technology, Inc. Device 8091 | \-00.2 Integrated Device Technology, Inc. Device 8091 +-03.0-[05-0d]----00.0-[06-0d]----01.0-[07-0d]----00.0-[08-0d]--+-01.0-[09]-- | +-05.0-[0a]-- | +-07.0-[0b]-- | \-09.0-[0c-0d]--+-00.0-[0d]-- | +-00.1 Integrated Device Technology, Inc. Device 8091 | \-00.2 Integrated Device Technology, Inc. Device 8091 +-03.2-[0e-16]----00.0-[0f-16]----01.0-[10-16]----00.0-[11-16]--+-01.0-[12]-- | +-05.0-[13]-- | +-07.0-[14]-- | \-09.0-[15-16]--+-00.0-[16]-- | +-00.1 Integrated Device Technology, Inc. Device 8091 | \-00.2 Integrated Device Technology, Inc. Device 8091 +-04.0 Intel Corporation Device 6f20 +-04.1 Intel Corporation Device 6f21 +-04.2 Intel Corporation Device 6f22 +-04.3 Intel Corporation Device 6f23 +-04.4 Intel Corporation Device 6f24 +-04.5 Intel Corporation Device 6f25 +-04.6 Intel Corporation Device 6f26 +-04.7 Intel Corporation Device 6f27 +-05.0 Intel Corporation Device 6f28 +-05.1 Intel Corporation Device 6f29 +-05.2 Intel Corporation Device 6f2a +-05.4 Intel Corporation Device 6f2c +-11.0 Intel Corporation Device 8d7c +-11.4 Intel Corporation Device 8d62 +-14.0 Intel Corporation Device 8d31 +-16.0 Intel Corporation Device 8d3a +-16.1 Intel Corporation Device 8d3b +-1a.0 Intel Corporation Device 8d2d +-1c.0-[17]-- +-1c.2-[18-19]----00.0-[19]----00.0 ASPEED Technology, Inc. ASPEED Graphics Family +-1c.4-[1a]--+-00.0 Intel Corporation Device 1521 | \-00.1 Intel Corporation Device 1521 +-1d.0 Intel Corporation Device 8d26 +-1f.0 Intel Corporation Device 8d44 +-1f.2 Intel Corporation Device 8d02 \-1f.3 Intel Corporation Device 8d22 COMMAND: /usr/sbin/lspci -vvv 00:00.0 Host bridge: Intel Corporation Device 6f00 (rev 01) Subsystem: Super Micro Computer Inc Device 0833 Control: I/O- Mem- BusMaster- SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- DisINTx+ Status: Cap+ 66MHz- UDF- FastB2B- ParErr- DEVSEL=fast >TAbort- SERR- Capabilities: [144] Vendor Specific Information Capabilities: [1d0] Vendor Specific Information Capabilities: [280] Vendor Specific Information Capabilities: [300] Vendor Specific Information 00:01.0 PCI bridge: Intel Corporation Device 6f02 (rev 01) (prog-if 00 [Normal decode]) Control: I/O+ Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- DisINTx+ Status: Cap+ 66MHz- UDF- FastB2B- ParErr- DEVSEL=fast >TAbort- SERR- TAbort- Reset- FastB2B- PriDiscTmr- SecDiscTmr- DiscTmrStat- DiscTmrSERREn- Capabilities: [40] Subsystem: Super Micro Computer Inc Device 0833 Capabilities: [60] MSI: Enable+ Count=1/2 Maskable+ 64bit- Address: fee00000 Data: 4079 Masking: 00000003 Pending: 00000000 Capabilities: [90] Express (v2) Root Port (Slot+), MSI 00 DevCap: MaxPayload 256 bytes, PhantFunc 0, Latency L0s <64ns, L1 <1us ExtTag- RBE+ FLReset- DevCtl: Report errors: Correctable- Non-Fatal- Fatal- Unsupported- RlxdOrd- ExtTag- PhantFunc- AuxPwr- NoSnoop- MaxPayload 128 bytes, MaxReadReq 128 bytes DevSta: CorrErr- UncorrErr- FatalErr- UnsuppReq- AuxPwr- TransPend- LnkCap: Port #1, Speed unknown, Width x8, ASPM unknown, Latency L0 <512ns, L1 <16us ClockPM- Surprise+ LLActRep+ BwNot+ LnkCtl: ASPM Disabled; RCB 64 bytes Disabled- Retrain- CommClk+ ExtSynch- ClockPM- AutWidDis- BWInt- AutBWInt- LnkSta: Speed 2.5GT/s, Width x0, TrErr- Train- SlotClk+ DLActive- BWMgmt- ABWMgmt- SltCap: AttnBtn- PwrCtrl- MRL- AttnInd- PwrInd- HotPlug- Surpise+ Slot # 0, PowerLimit 25.000000; Interlock- NoCompl- SltCtl: Enable: AttnBtn- PwrFlt- MRL- PresDet- CmdCplt- HPIrq- LinkChg- Control: AttnInd Off, PwrInd Off, Power- Interlock- SltSta: Status: AttnBtn- PowerFlt- MRL- CmdCplt- PresDet- Interlock- Changed: MRL- PresDet- LinkState- RootCtl: ErrCorrectable- ErrNon-Fatal- ErrFatal- PMEIntEna- CRSVisible- RootCap: CRSVisible- RootSta: PME ReqID 0000, PMEStatus- PMEPending- DevCap2: Completion Timeout: Range BCD, TimeoutDis+ ARIFwd+ DevCtl2: Completion Timeout: 50us to 50ms, TimeoutDis- ARIFwd- LnkCtl2: Target Link Speed: Unknown, EnterCompliance- SpeedDis-, Selectable De-emphasis: -6dB Transmit Margin: Normal Operating Range, EnterModifiedCompliance- ComplianceSOS- Compliance De-emphasis: -6dB LnkSta2: Current De-emphasis Level: -6dB Capabilities: [e0] Power Management version 3 Flags: PMEClk- DSI- D1- D2- AuxCurrent=0mA PME(D0+,D1-,D2-,D3hot+,D3cold+) Status: D0 NoSoftRst+ PME-Enable- DSel=0 DScale=0 PME- Capabilities: [100] Vendor Specific Information Capabilities: [110] Access Control Services ACSCap: SrcValid+ TransBlk+ ReqRedir+ CmpltRedir+ UpstreamFwd+ EgressCtrl- DirectTrans- ACSCtl: SrcValid- TransBlk- ReqRedir- CmpltRedir- UpstreamFwd- EgressCtrl- DirectTrans- Capabilities: [148] Advanced Error Reporting UESta: DLP- SDES- TLP- FCP- CmpltTO- CmpltAbrt- UnxCmplt- RxOF- MalfTLP- ECRC- UnsupReq- ACSViol- UEMsk: DLP- SDES- TLP- FCP- CmpltTO- CmpltAbrt- UnxCmplt- RxOF- MalfTLP- ECRC- UnsupReq- ACSViol- UESvrt: DLP+ SDES+ TLP- FCP+ CmpltTO- CmpltAbrt- UnxCmplt- RxOF+ MalfTLP+ ECRC- UnsupReq- ACSViol- CESta: RxErr- BadTLP- BadDLLP- Rollover- Timeout- NonFatalErr- CEMsk: RxErr- BadTLP- BadDLLP- Rollover- Timeout- NonFatalErr+ AERCap: First Error Pointer: 00, GenCap+ CGenEn- ChkCap+ ChkEn- Capabilities: [1d0] Vendor Specific Information Capabilities: [250] #19 Capabilities: [280] Vendor Specific Information Capabilities: [300] Vendor Specific Information Kernel driver in use: pcieport 00:02.0 PCI bridge: Intel Corporation Device 6f04 (rev 01) (prog-if 00 [Normal decode]) Control: I/O+ Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- DisINTx+ Status: Cap+ 66MHz- UDF- FastB2B- ParErr- DEVSEL=fast >TAbort- SERR- TAbort- Reset- FastB2B- PriDiscTmr- SecDiscTmr- DiscTmrStat- DiscTmrSERREn- Capabilities: [40] Subsystem: Super Micro Computer Inc Device 0833 Capabilities: [60] MSI: Enable+ Count=1/2 Maskable+ 64bit- Address: fee00000 Data: 4081 Masking: 00000003 Pending: 00000000 Capabilities: [90] Express (v2) Root Port (Slot+), MSI 00 DevCap: MaxPayload 256 bytes, PhantFunc 0, Latency L0s <64ns, L1 <1us ExtTag- RBE+ FLReset- DevCtl: Report errors: Correctable- Non-Fatal- Fatal- Unsupported- RlxdOrd- ExtTag- PhantFunc- AuxPwr- NoSnoop- MaxPayload 128 bytes, MaxReadReq 128 bytes DevSta: CorrErr- UncorrErr- FatalErr- UnsuppReq- AuxPwr- TransPend- LnkCap: Port #3, Speed unknown, Width x8, ASPM unknown, Latency L0 <512ns, L1 <16us ClockPM- Surprise+ LLActRep+ BwNot+ LnkCtl: ASPM Disabled; RCB 64 bytes Disabled- Retrain- CommClk+ ExtSynch- ClockPM- AutWidDis- BWInt- AutBWInt- LnkSta: Speed 2.5GT/s, Width x0, TrErr- Train- SlotClk+ DLActive- BWMgmt- ABWMgmt- SltCap: AttnBtn- PwrCtrl- MRL- AttnInd- PwrInd- HotPlug- Surpise+ Slot # 4, PowerLimit 25.000000; Interlock- NoCompl- SltCtl: Enable: AttnBtn- PwrFlt- MRL- PresDet- CmdCplt- HPIrq- LinkChg- Control: AttnInd Off, PwrInd Off, Power- Interlock- SltSta: Status: AttnBtn- PowerFlt- MRL- CmdCplt- PresDet- Interlock- Changed: MRL- PresDet- LinkState- RootCtl: ErrCorrectable- ErrNon-Fatal- ErrFatal- PMEIntEna- CRSVisible- RootCap: CRSVisible- RootSta: PME ReqID 0000, PMEStatus- PMEPending- DevCap2: Completion Timeout: Range BCD, TimeoutDis+ ARIFwd+ DevCtl2: Completion Timeout: 50us to 50ms, TimeoutDis- ARIFwd- LnkCtl2: Target Link Speed: Unknown, EnterCompliance- SpeedDis-, Selectable De-emphasis: -6dB Transmit Margin: Normal Operating Range, EnterModifiedCompliance- ComplianceSOS- Compliance De-emphasis: -6dB LnkSta2: Current De-emphasis Level: -6dB Capabilities: [e0] Power Management version 3 Flags: PMEClk- DSI- D1- D2- AuxCurrent=0mA PME(D0+,D1-,D2-,D3hot+,D3cold+) Status: D0 NoSoftRst+ PME-Enable- DSel=0 DScale=0 PME- Capabilities: [100] Vendor Specific Information Capabilities: [110] Access Control Services ACSCap: SrcValid+ TransBlk+ ReqRedir+ CmpltRedir+ UpstreamFwd+ EgressCtrl- DirectTrans- ACSCtl: SrcValid- TransBlk- ReqRedir- CmpltRedir- UpstreamFwd- EgressCtrl- DirectTrans- Capabilities: [148] Advanced Error Reporting UESta: DLP- SDES- TLP- FCP- CmpltTO- CmpltAbrt- UnxCmplt- RxOF- MalfTLP- ECRC- UnsupReq- ACSViol- UEMsk: DLP- SDES- TLP- FCP- CmpltTO- CmpltAbrt- UnxCmplt- RxOF- MalfTLP- ECRC- UnsupReq- ACSViol- UESvrt: DLP+ SDES+ TLP- FCP+ CmpltTO- CmpltAbrt- UnxCmplt- RxOF+ MalfTLP+ ECRC- UnsupReq- ACSViol- CESta: RxErr- BadTLP- BadDLLP- Rollover- Timeout- NonFatalErr- CEMsk: RxErr- BadTLP- BadDLLP- Rollover- Timeout- NonFatalErr+ AERCap: First Error Pointer: 00, GenCap+ CGenEn- ChkCap+ ChkEn- Capabilities: [1d0] Vendor Specific Information Capabilities: [250] #19 Capabilities: [280] Vendor Specific Information Capabilities: [300] Vendor Specific Information Kernel driver in use: pcieport 00:02.2 PCI bridge: Intel Corporation Device 6f06 (rev 01) (prog-if 00 [Normal decode]) Control: I/O+ Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- DisINTx+ Status: Cap+ 66MHz- UDF- FastB2B- ParErr- DEVSEL=fast >TAbort- SERR- TAbort- Reset- FastB2B- PriDiscTmr- SecDiscTmr- DiscTmrStat- DiscTmrSERREn- Capabilities: [40] Subsystem: Super Micro Computer Inc Device 0833 Capabilities: [60] MSI: Enable+ Count=1/2 Maskable+ 64bit- Address: fee00000 Data: 4089 Masking: 00000003 Pending: 00000000 Capabilities: [90] Express (v2) Root Port (Slot+), MSI 00 DevCap: MaxPayload 256 bytes, PhantFunc 0, Latency L0s <64ns, L1 <1us ExtTag- RBE+ FLReset- DevCtl: Report errors: Correctable- Non-Fatal- Fatal- Unsupported- RlxdOrd- ExtTag- PhantFunc- AuxPwr- NoSnoop- MaxPayload 256 bytes, MaxReadReq 128 bytes DevSta: CorrErr- UncorrErr- FatalErr- UnsuppReq- AuxPwr- TransPend- LnkCap: Port #5, Speed unknown, Width x8, ASPM unknown, Latency L0 <512ns, L1 <16us ClockPM- Surprise+ LLActRep+ BwNot+ LnkCtl: ASPM Disabled; RCB 64 bytes Disabled- Retrain- CommClk- ExtSynch- ClockPM- AutWidDis- BWInt- AutBWInt- LnkSta: Speed 5GT/s, Width x8, TrErr- Train- SlotClk+ DLActive+ BWMgmt+ ABWMgmt- SltCap: AttnBtn- PwrCtrl- MRL- AttnInd- PwrInd- HotPlug- Surpise+ Slot # 3, PowerLimit 25.000000; Interlock- NoCompl- SltCtl: Enable: AttnBtn- PwrFlt- MRL- PresDet- CmdCplt- HPIrq- LinkChg- Control: AttnInd Off, PwrInd Off, Power- Interlock- SltSta: Status: AttnBtn- PowerFlt- MRL- CmdCplt- PresDet+ Interlock- Changed: MRL- PresDet- LinkState- RootCtl: ErrCorrectable- ErrNon-Fatal- ErrFatal- PMEIntEna- CRSVisible- RootCap: CRSVisible- RootSta: PME ReqID 0000, PMEStatus- PMEPending- DevCap2: Completion Timeout: Range BCD, TimeoutDis+ ARIFwd+ DevCtl2: Completion Timeout: 50us to 50ms, TimeoutDis- ARIFwd- LnkCtl2: Target Link Speed: 5GT/s, EnterCompliance- SpeedDis-, Selectable De-emphasis: -6dB Transmit Margin: Normal Operating Range, EnterModifiedCompliance- ComplianceSOS- Compliance De-emphasis: -6dB LnkSta2: Current De-emphasis Level: -6dB Capabilities: [e0] Power Management version 3 Flags: PMEClk- DSI- D1- D2- AuxCurrent=0mA PME(D0+,D1-,D2-,D3hot+,D3cold+) Status: D0 NoSoftRst+ PME-Enable- DSel=0 DScale=0 PME- Capabilities: [100] Vendor Specific Information Capabilities: [110] Access Control Services ACSCap: SrcValid+ TransBlk+ ReqRedir+ CmpltRedir+ UpstreamFwd+ EgressCtrl- DirectTrans- ACSCtl: SrcValid- TransBlk- ReqRedir- CmpltRedir- UpstreamFwd- EgressCtrl- DirectTrans- Capabilities: [148] Advanced Error Reporting UESta: DLP- SDES- TLP- FCP- CmpltTO- CmpltAbrt- UnxCmplt- RxOF- MalfTLP- ECRC- UnsupReq- ACSViol- UEMsk: DLP- SDES- TLP- FCP- CmpltTO- CmpltAbrt- UnxCmplt- RxOF- MalfTLP- ECRC- UnsupReq- ACSViol- UESvrt: DLP+ SDES+ TLP- FCP+ CmpltTO- CmpltAbrt- UnxCmplt- RxOF+ MalfTLP+ ECRC- UnsupReq- ACSViol- CESta: RxErr- BadTLP- BadDLLP- Rollover- Timeout- NonFatalErr- CEMsk: RxErr- BadTLP- BadDLLP- Rollover- Timeout- NonFatalErr+ AERCap: First Error Pointer: 00, GenCap+ CGenEn- ChkCap+ ChkEn- Capabilities: [1d0] Vendor Specific Information Capabilities: [250] #19 Capabilities: [280] Vendor Specific Information Capabilities: [300] Vendor Specific Information Kernel driver in use: pcieport 00:03.0 PCI bridge: Intel Corporation Device 6f08 (rev 01) (prog-if 00 [Normal decode]) Control: I/O+ Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- DisINTx+ Status: Cap+ 66MHz- UDF- FastB2B- ParErr- DEVSEL=fast >TAbort- SERR- TAbort- Reset- FastB2B- PriDiscTmr- SecDiscTmr- DiscTmrStat- DiscTmrSERREn- Capabilities: [40] Subsystem: Super Micro Computer Inc Device 0833 Capabilities: [60] MSI: Enable+ Count=1/2 Maskable+ 64bit- Address: fee00000 Data: 4091 Masking: 00000003 Pending: 00000000 Capabilities: [90] Express (v2) Root Port (Slot+), MSI 00 DevCap: MaxPayload 256 bytes, PhantFunc 0, Latency L0s <64ns, L1 <1us ExtTag- RBE+ FLReset- DevCtl: Report errors: Correctable- Non-Fatal- Fatal- Unsupported- RlxdOrd- ExtTag- PhantFunc- AuxPwr- NoSnoop- MaxPayload 256 bytes, MaxReadReq 128 bytes DevSta: CorrErr- UncorrErr- FatalErr- UnsuppReq- AuxPwr- TransPend- LnkCap: Port #7, Speed unknown, Width x8, ASPM unknown, Latency L0 <512ns, L1 <16us ClockPM- Surprise+ LLActRep+ BwNot+ LnkCtl: ASPM Disabled; RCB 64 bytes Disabled- Retrain- CommClk- ExtSynch- ClockPM- AutWidDis- BWInt- AutBWInt- LnkSta: Speed 5GT/s, Width x1, TrErr- Train- SlotClk+ DLActive+ BWMgmt+ ABWMgmt- SltCap: AttnBtn- PwrCtrl- MRL- AttnInd- PwrInd- HotPlug- Surpise+ Slot # 1, PowerLimit 25.000000; Interlock- NoCompl- SltCtl: Enable: AttnBtn- PwrFlt- MRL- PresDet- CmdCplt- HPIrq- LinkChg- Control: AttnInd Off, PwrInd Off, Power- Interlock- SltSta: Status: AttnBtn- PowerFlt- MRL- CmdCplt- PresDet+ Interlock- Changed: MRL- PresDet- LinkState- RootCtl: ErrCorrectable- ErrNon-Fatal- ErrFatal- PMEIntEna- CRSVisible- RootCap: CRSVisible- RootSta: PME ReqID 0000, PMEStatus- PMEPending- DevCap2: Completion Timeout: Range BCD, TimeoutDis+ ARIFwd+ DevCtl2: Completion Timeout: 50us to 50ms, TimeoutDis- ARIFwd- LnkCtl2: Target Link Speed: 5GT/s, EnterCompliance- SpeedDis-, Selectable De-emphasis: -6dB Transmit Margin: Normal Operating Range, EnterModifiedCompliance- ComplianceSOS- Compliance De-emphasis: -6dB LnkSta2: Current De-emphasis Level: -6dB Capabilities: [e0] Power Management version 3 Flags: PMEClk- DSI- D1- D2- AuxCurrent=0mA PME(D0+,D1-,D2-,D3hot+,D3cold+) Status: D0 NoSoftRst+ PME-Enable- DSel=0 DScale=0 PME- Capabilities: [100] Vendor Specific Information Capabilities: [110] Access Control Services ACSCap: SrcValid+ TransBlk+ ReqRedir+ CmpltRedir+ UpstreamFwd+ EgressCtrl- DirectTrans- ACSCtl: SrcValid- TransBlk- ReqRedir- CmpltRedir- UpstreamFwd- EgressCtrl- DirectTrans- Capabilities: [148] Advanced Error Reporting UESta: DLP- SDES- TLP- FCP- CmpltTO- CmpltAbrt- UnxCmplt- RxOF- MalfTLP- ECRC- UnsupReq- ACSViol- UEMsk: DLP- SDES- TLP- FCP- CmpltTO- CmpltAbrt- UnxCmplt- RxOF- MalfTLP- ECRC- UnsupReq- ACSViol- UESvrt: DLP+ SDES+ TLP- FCP+ CmpltTO- CmpltAbrt- UnxCmplt- RxOF+ MalfTLP+ ECRC- UnsupReq- ACSViol- CESta: RxErr- BadTLP- BadDLLP- Rollover- Timeout- NonFatalErr- CEMsk: RxErr- BadTLP- BadDLLP- Rollover- Timeout- NonFatalErr+ AERCap: First Error Pointer: 00, GenCap+ CGenEn- ChkCap+ ChkEn- Capabilities: [1d0] Vendor Specific Information Capabilities: [250] #19 Capabilities: [280] Vendor Specific Information Capabilities: [300] Vendor Specific Information Kernel driver in use: pcieport 00:03.2 PCI bridge: Intel Corporation Device 6f0a (rev 01) (prog-if 00 [Normal decode]) Control: I/O+ Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- DisINTx+ Status: Cap+ 66MHz- UDF- FastB2B- ParErr- DEVSEL=fast >TAbort- SERR- TAbort- Reset- FastB2B- PriDiscTmr- SecDiscTmr- DiscTmrStat- DiscTmrSERREn- Capabilities: [40] Subsystem: Super Micro Computer Inc Device 0833 Capabilities: [60] MSI: Enable+ Count=1/2 Maskable+ 64bit- Address: fee00000 Data: 4099 Masking: 00000003 Pending: 00000000 Capabilities: [90] Express (v2) Root Port (Slot+), MSI 00 DevCap: MaxPayload 256 bytes, PhantFunc 0, Latency L0s <64ns, L1 <1us ExtTag- RBE+ FLReset- DevCtl: Report errors: Correctable- Non-Fatal- Fatal- Unsupported- RlxdOrd- ExtTag- PhantFunc- AuxPwr- NoSnoop- MaxPayload 256 bytes, MaxReadReq 128 bytes DevSta: CorrErr- UncorrErr- FatalErr- UnsuppReq- AuxPwr- TransPend- LnkCap: Port #9, Speed unknown, Width x8, ASPM unknown, Latency L0 <512ns, L1 <16us ClockPM- Surprise+ LLActRep+ BwNot+ LnkCtl: ASPM Disabled; RCB 64 bytes Disabled- Retrain- CommClk- ExtSynch- ClockPM- AutWidDis- BWInt- AutBWInt- LnkSta: Speed 5GT/s, Width x1, TrErr- Train- SlotClk+ DLActive+ BWMgmt+ ABWMgmt- SltCap: AttnBtn- PwrCtrl- MRL- AttnInd- PwrInd- HotPlug- Surpise+ Slot # 2, PowerLimit 25.000000; Interlock- NoCompl- SltCtl: Enable: AttnBtn- PwrFlt- MRL- PresDet- CmdCplt- HPIrq- LinkChg- Control: AttnInd Off, PwrInd Off, Power- Interlock- SltSta: Status: AttnBtn- PowerFlt- MRL- CmdCplt- PresDet+ Interlock- Changed: MRL- PresDet- LinkState- RootCtl: ErrCorrectable- ErrNon-Fatal- ErrFatal- PMEIntEna- CRSVisible- RootCap: CRSVisible- RootSta: PME ReqID 0000, PMEStatus- PMEPending- DevCap2: Completion Timeout: Range BCD, TimeoutDis+ ARIFwd+ DevCtl2: Completion Timeout: 50us to 50ms, TimeoutDis- ARIFwd- LnkCtl2: Target Link Speed: 5GT/s, EnterCompliance- SpeedDis-, Selectable De-emphasis: -6dB Transmit Margin: Normal Operating Range, EnterModifiedCompliance- ComplianceSOS- Compliance De-emphasis: -6dB LnkSta2: Current De-emphasis Level: -6dB Capabilities: [e0] Power Management version 3 Flags: PMEClk- DSI- D1- D2- AuxCurrent=0mA PME(D0+,D1-,D2-,D3hot+,D3cold+) Status: D0 NoSoftRst+ PME-Enable- DSel=0 DScale=0 PME- Capabilities: [100] Vendor Specific Information Capabilities: [110] Access Control Services ACSCap: SrcValid+ TransBlk+ ReqRedir+ CmpltRedir+ UpstreamFwd+ EgressCtrl- DirectTrans- ACSCtl: SrcValid- TransBlk- ReqRedir- CmpltRedir- UpstreamFwd- EgressCtrl- DirectTrans- Capabilities: [148] Advanced Error Reporting UESta: DLP- SDES- TLP- FCP- CmpltTO- CmpltAbrt- UnxCmplt- RxOF- MalfTLP- ECRC- UnsupReq- ACSViol- UEMsk: DLP- SDES- TLP- FCP- CmpltTO- CmpltAbrt- UnxCmplt- RxOF- MalfTLP- ECRC- UnsupReq- ACSViol- UESvrt: DLP+ SDES+ TLP- FCP+ CmpltTO- CmpltAbrt- UnxCmplt- RxOF+ MalfTLP+ ECRC- UnsupReq- ACSViol- CESta: RxErr- BadTLP- BadDLLP- Rollover- Timeout- NonFatalErr- CEMsk: RxErr- BadTLP- BadDLLP- Rollover- Timeout- NonFatalErr+ AERCap: First Error Pointer: 00, GenCap+ CGenEn- ChkCap+ ChkEn- Capabilities: [1d0] Vendor Specific Information Capabilities: [250] #19 Capabilities: [280] Vendor Specific Information Capabilities: [300] Vendor Specific Information Kernel driver in use: pcieport 00:04.0 System peripheral: Intel Corporation Device 6f20 (rev 01) Subsystem: Super Micro Computer Inc Device 0833 Control: I/O- Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- DisINTx- Status: Cap+ 66MHz- UDF- FastB2B- ParErr- DEVSEL=fast >TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- SERR- Capabilities: [110] Vendor Specific Information Capabilities: [120] Vendor Specific Information Capabilities: [130] Vendor Specific Information 00:05.2 System peripheral: Intel Corporation Device 6f2a (rev 01) Subsystem: Super Micro Computer Inc Device 0833 Control: I/O- Mem- BusMaster- SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- DisINTx- Status: Cap+ 66MHz- UDF- FastB2B- ParErr- DEVSEL=fast >TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- SERR- Kernel driver in use: ahci 00:14.0 USB Controller: Intel Corporation Device 8d31 (rev 05) (prog-if 30) Subsystem: Super Micro Computer Inc Device 0833 Control: I/O- Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- DisINTx- Status: Cap+ 66MHz- UDF- FastB2B+ ParErr- DEVSEL=medium >TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- Reset- FastB2B- PriDiscTmr- SecDiscTmr- DiscTmrStat- DiscTmrSERREn- Capabilities: [40] Express (v2) Root Port (Slot-), MSI 00 DevCap: MaxPayload 128 bytes, PhantFunc 0, Latency L0s <64ns, L1 <1us ExtTag- RBE+ FLReset- DevCtl: Report errors: Correctable- Non-Fatal- Fatal- Unsupported- RlxdOrd- ExtTag- PhantFunc- AuxPwr- NoSnoop- MaxPayload 128 bytes, MaxReadReq 128 bytes DevSta: CorrErr- UncorrErr- FatalErr- UnsuppReq- AuxPwr+ TransPend- LnkCap: Port #1, Speed 5GT/s, Width x1, ASPM L0s L1, Latency L0 <1us, L1 <4us ClockPM- Surprise- LLActRep+ BwNot+ LnkCtl: ASPM Disabled; RCB 64 bytes Disabled- Retrain- CommClk- ExtSynch- ClockPM- AutWidDis- BWInt- AutBWInt- LnkSta: Speed 2.5GT/s, Width x0, TrErr- Train- SlotClk+ DLActive- BWMgmt- ABWMgmt- RootCtl: ErrCorrectable- ErrNon-Fatal- ErrFatal- PMEIntEna- CRSVisible- RootCap: CRSVisible- RootSta: PME ReqID 0000, PMEStatus- PMEPending- DevCap2: Completion Timeout: Range ABC, TimeoutDis+ ARIFwd- DevCtl2: Completion Timeout: 50us to 50ms, TimeoutDis- ARIFwd- LnkCtl2: Target Link Speed: 5GT/s, EnterCompliance- SpeedDis-, Selectable De-emphasis: -6dB Transmit Margin: Normal Operating Range, EnterModifiedCompliance- ComplianceSOS- Compliance De-emphasis: -6dB LnkSta2: Current De-emphasis Level: -3.5dB Capabilities: [80] MSI: Enable+ Count=1/1 Maskable- 64bit- Address: fee00000 Data: 40a1 Capabilities: [90] Subsystem: Super Micro Computer Inc Device 0833 Capabilities: [a0] Power Management version 3 Flags: PMEClk- DSI- D1- D2- AuxCurrent=0mA PME(D0+,D1-,D2-,D3hot+,D3cold+) Status: D0 NoSoftRst- PME-Enable- DSel=0 DScale=0 PME- Kernel driver in use: pcieport 00:1c.2 PCI bridge: Intel Corporation Device 8d14 (rev d5) (prog-if 00 [Normal decode]) Control: I/O+ Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- DisINTx+ Status: Cap+ 66MHz- UDF- FastB2B- ParErr- DEVSEL=fast >TAbort- SERR- TAbort- Reset- FastB2B- PriDiscTmr- SecDiscTmr- DiscTmrStat- DiscTmrSERREn- Capabilities: [40] Express (v2) Root Port (Slot+), MSI 00 DevCap: MaxPayload 128 bytes, PhantFunc 0, Latency L0s <64ns, L1 <1us ExtTag- RBE+ FLReset- DevCtl: Report errors: Correctable- Non-Fatal- Fatal- Unsupported- RlxdOrd- ExtTag- PhantFunc- AuxPwr- NoSnoop- MaxPayload 128 bytes, MaxReadReq 128 bytes DevSta: CorrErr- UncorrErr- FatalErr- UnsuppReq- AuxPwr+ TransPend- LnkCap: Port #3, Speed 5GT/s, Width x1, ASPM L0s L1, Latency L0 <512ns, L1 <4us ClockPM- Surprise- LLActRep+ BwNot+ LnkCtl: ASPM Disabled; RCB 64 bytes Disabled- Retrain- CommClk+ ExtSynch- ClockPM- AutWidDis- BWInt- AutBWInt- LnkSta: Speed 2.5GT/s, Width x1, TrErr- Train- SlotClk+ DLActive+ BWMgmt+ ABWMgmt- SltCap: AttnBtn- PwrCtrl- MRL- AttnInd- PwrInd- HotPlug- Surpise- Slot # 0, PowerLimit 0.000000; Interlock- NoCompl+ SltCtl: Enable: AttnBtn- PwrFlt- MRL- PresDet- CmdCplt- HPIrq- LinkChg- Control: AttnInd Unknown, PwrInd Unknown, Power- Interlock- SltSta: Status: AttnBtn- PowerFlt- MRL- CmdCplt- PresDet+ Interlock- Changed: MRL- PresDet- LinkState- RootCtl: ErrCorrectable- ErrNon-Fatal- ErrFatal- PMEIntEna- CRSVisible- RootCap: CRSVisible- RootSta: PME ReqID 0000, PMEStatus- PMEPending- DevCap2: Completion Timeout: Range ABC, TimeoutDis+ ARIFwd- DevCtl2: Completion Timeout: 50us to 50ms, TimeoutDis- ARIFwd- LnkCtl2: Target Link Speed: 5GT/s, EnterCompliance- SpeedDis-, Selectable De-emphasis: -6dB Transmit Margin: Normal Operating Range, EnterModifiedCompliance- ComplianceSOS- Compliance De-emphasis: -6dB LnkSta2: Current De-emphasis Level: -3.5dB Capabilities: [80] MSI: Enable+ Count=1/1 Maskable- 64bit- Address: fee00000 Data: 40a9 Capabilities: [90] Subsystem: Super Micro Computer Inc Device 0833 Capabilities: [a0] Power Management version 3 Flags: PMEClk- DSI- D1- D2- AuxCurrent=0mA PME(D0+,D1-,D2-,D3hot+,D3cold+) Status: D0 NoSoftRst- PME-Enable- DSel=0 DScale=0 PME- Kernel driver in use: pcieport 00:1c.4 PCI bridge: Intel Corporation Device 8d18 (rev d5) (prog-if 00 [Normal decode]) Control: I/O+ Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- DisINTx+ Status: Cap+ 66MHz- UDF- FastB2B- ParErr- DEVSEL=fast >TAbort- SERR- TAbort- Reset- FastB2B- PriDiscTmr- SecDiscTmr- DiscTmrStat- DiscTmrSERREn- Capabilities: [40] Express (v2) Root Port (Slot+), MSI 00 DevCap: MaxPayload 128 bytes, PhantFunc 0, Latency L0s <64ns, L1 <1us ExtTag- RBE+ FLReset- DevCtl: Report errors: Correctable- Non-Fatal- Fatal- Unsupported- RlxdOrd- ExtTag- PhantFunc- AuxPwr- NoSnoop- MaxPayload 128 bytes, MaxReadReq 128 bytes DevSta: CorrErr- UncorrErr- FatalErr- UnsuppReq- AuxPwr+ TransPend- LnkCap: Port #5, Speed 5GT/s, Width x4, ASPM L0s L1, Latency L0 <512ns, L1 <4us ClockPM- Surprise- LLActRep+ BwNot+ LnkCtl: ASPM Disabled; RCB 64 bytes Disabled- Retrain- CommClk+ ExtSynch- ClockPM- AutWidDis- BWInt- AutBWInt- LnkSta: Speed 5GT/s, Width x4, TrErr- Train- SlotClk+ DLActive+ BWMgmt+ ABWMgmt+ SltCap: AttnBtn- PwrCtrl- MRL- AttnInd- PwrInd- HotPlug- Surpise- Slot # 0, PowerLimit 0.000000; Interlock- NoCompl+ SltCtl: Enable: AttnBtn- PwrFlt- MRL- PresDet- CmdCplt- HPIrq- LinkChg- Control: AttnInd Unknown, PwrInd Unknown, Power- Interlock- SltSta: Status: AttnBtn- PowerFlt- MRL- CmdCplt- PresDet+ Interlock- Changed: MRL- PresDet- LinkState- RootCtl: ErrCorrectable- ErrNon-Fatal- ErrFatal- PMEIntEna- CRSVisible- RootCap: CRSVisible- RootSta: PME ReqID 0000, PMEStatus- PMEPending- DevCap2: Completion Timeout: Range ABC, TimeoutDis+ ARIFwd- DevCtl2: Completion Timeout: 50us to 50ms, TimeoutDis- ARIFwd- LnkCtl2: Target Link Speed: 5GT/s, EnterCompliance- SpeedDis-, Selectable De-emphasis: -6dB Transmit Margin: Normal Operating Range, EnterModifiedCompliance- ComplianceSOS- Compliance De-emphasis: -6dB LnkSta2: Current De-emphasis Level: -6dB Capabilities: [80] MSI: Enable+ Count=1/1 Maskable- 64bit- Address: fee00000 Data: 40b1 Capabilities: [90] Subsystem: Super Micro Computer Inc Device 0833 Capabilities: [a0] Power Management version 3 Flags: PMEClk- DSI- D1- D2- AuxCurrent=0mA PME(D0+,D1-,D2-,D3hot+,D3cold+) Status: D0 NoSoftRst- PME-Enable- DSel=0 DScale=0 PME- Kernel driver in use: pcieport 00:1d.0 USB Controller: Intel Corporation Device 8d26 (rev 05) (prog-if 20 [EHCI]) Subsystem: Super Micro Computer Inc Device 0833 Control: I/O- Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- DisINTx- Status: Cap+ 66MHz- UDF- FastB2B+ ParErr- DEVSEL=medium >TAbort- SERR- TAbort- SERR- 00:1f.2 SATA controller: Intel Corporation Device 8d02 (rev 05) (prog-if 01 [AHCI 1.0]) Subsystem: Super Micro Computer Inc Device 0833 Control: I/O+ Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- DisINTx+ Status: Cap+ 66MHz+ UDF- FastB2B+ ParErr- DEVSEL=medium >TAbort- SERR- Kernel driver in use: ahci 00:1f.3 SMBus: Intel Corporation Device 8d22 (rev 05) Subsystem: Super Micro Computer Inc Device 0833 Control: I/O+ Mem+ BusMaster- SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- DisINTx- Status: Cap- 66MHz- UDF- FastB2B+ ParErr- DEVSEL=medium >TAbort- SERR- TAbort- SERR- TAbort- Reset- FastB2B- PriDiscTmr- SecDiscTmr- DiscTmrStat- DiscTmrSERREn- Capabilities: [40] Express (v2) Upstream Port, MSI 00 DevCap: MaxPayload 2048 bytes, PhantFunc 0, Latency L0s <64ns, L1 <1us ExtTag+ AttnBtn- AttnInd- PwrInd- RBE+ FLReset-SlotPowerLimit 25.000000W DevCtl: Report errors: Correctable- Non-Fatal- Fatal- Unsupported- RlxdOrd- ExtTag- PhantFunc- AuxPwr- NoSnoop- MaxPayload 256 bytes, MaxReadReq 128 bytes DevSta: CorrErr+ UncorrErr- FatalErr- UnsuppReq+ AuxPwr- TransPend- LnkCap: Port #0, Speed 5GT/s, Width x8, ASPM L0s L1, Latency L0 <4us, L1 <4us ClockPM- Surprise- LLActRep- BwNot- LnkCtl: ASPM Disabled; Disabled- Retrain- CommClk- ExtSynch- ClockPM- AutWidDis- BWInt- AutBWInt- LnkSta: Speed 5GT/s, Width x8, TrErr- Train- SlotClk- DLActive- BWMgmt- ABWMgmt- DevCap2: Completion Timeout: Not Supported, TimeoutDis- DevCtl2: Completion Timeout: 50us to 50ms, TimeoutDis- LnkCtl2: Target Link Speed: 5GT/s, EnterCompliance- SpeedDis-, Selectable De-emphasis: -6dB Transmit Margin: Normal Operating Range, EnterModifiedCompliance- ComplianceSOS- Compliance De-emphasis: -6dB LnkSta2: Current De-emphasis Level: -6dB Capabilities: [c0] Power Management version 3 Flags: PMEClk- DSI- D1- D2- AuxCurrent=0mA PME(D0+,D1-,D2-,D3hot+,D3cold+) Status: D0 NoSoftRst+ PME-Enable- DSel=0 DScale=0 PME- Capabilities: [f0] Subsystem: Dolphin Interconnect Solutions AS Device 0611 Capabilities: [100] Advanced Error Reporting UESta: DLP- SDES- TLP- FCP- CmpltTO- CmpltAbrt- UnxCmplt- RxOF- MalfTLP- ECRC- UnsupReq- ACSViol- UEMsk: DLP- SDES- TLP- FCP- CmpltTO- CmpltAbrt- UnxCmplt- RxOF- MalfTLP- ECRC- UnsupReq- ACSViol- UESvrt: DLP+ SDES+ TLP- FCP+ CmpltTO- CmpltAbrt- UnxCmplt- RxOF+ MalfTLP+ ECRC- UnsupReq- ACSViol- CESta: RxErr- BadTLP- BadDLLP- Rollover- Timeout- NonFatalErr+ CEMsk: RxErr- BadTLP- BadDLLP- Rollover- Timeout- NonFatalErr+ AERCap: First Error Pointer: 00, GenCap+ CGenEn- ChkCap+ ChkEn- Capabilities: [180] Device Serial Number 00-00-43-45-00-00-09-3d Capabilities: [200] Virtual Channel Capabilities: [330] #12 Kernel driver in use: pcieport 03:00.1 Bridge: Integrated Device Technology, Inc. Device 8091 (rev 02) Subsystem: Dolphin Interconnect Solutions AS Device 1611 Control: I/O+ Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- DisINTx+ Status: Cap+ 66MHz- UDF- FastB2B- ParErr- DEVSEL=fast >TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- Reset- FastB2B- PriDiscTmr- SecDiscTmr- DiscTmrStat- DiscTmrSERREn- Capabilities: [40] Power Management version 3 Flags: PMEClk- DSI- D1- D2- AuxCurrent=0mA PME(D0+,D1-,D2-,D3hot+,D3cold+) Status: D0 NoSoftRst+ PME-Enable- DSel=0 DScale=0 PME- Capabilities: [48] MSI: Enable+ Count=1/4 Maskable+ 64bit+ Address: 00000000fee00000 Data: 40b9 Masking: 00000001 Pending: 00000000 Capabilities: [68] Express (v2) Upstream Port, MSI 00 DevCap: MaxPayload 2048 bytes, PhantFunc 0, Latency L0s <64ns, L1 <1us ExtTag- AttnBtn- AttnInd- PwrInd- RBE+ FLReset-SlotPowerLimit 25.000000W DevCtl: Report errors: Correctable- Non-Fatal- Fatal- Unsupported- RlxdOrd- ExtTag- PhantFunc- AuxPwr- NoSnoop- MaxPayload 256 bytes, MaxReadReq 128 bytes DevSta: CorrErr+ UncorrErr- FatalErr- UnsuppReq+ AuxPwr- TransPend- LnkCap: Port #0, Speed 5GT/s, Width x4, ASPM L0s L1, Latency L0 <1us, L1 <2us ClockPM- Surprise- LLActRep- BwNot- LnkCtl: ASPM Disabled; Disabled- Retrain- CommClk- ExtSynch- ClockPM- AutWidDis- BWInt- AutBWInt- LnkSta: Speed 5GT/s, Width x1, TrErr- Train- SlotClk- DLActive- BWMgmt- ABWMgmt- DevCap2: Completion Timeout: Not Supported, TimeoutDis- DevCtl2: Completion Timeout: 50us to 50ms, TimeoutDis- LnkCtl2: Target Link Speed: 5GT/s, EnterCompliance- SpeedDis-, Selectable De-emphasis: -6dB Transmit Margin: Normal Operating Range, EnterModifiedCompliance- ComplianceSOS- Compliance De-emphasis: -6dB LnkSta2: Current De-emphasis Level: -6dB Capabilities: [a4] Subsystem: Adnaco Technology Inc. Device 0081 Capabilities: [100] Device Serial Number c9-81-17-79-b5-df-0e-00 Capabilities: [fb4] Advanced Error Reporting UESta: DLP- SDES- TLP- FCP- CmpltTO- CmpltAbrt- UnxCmplt- RxOF- MalfTLP- ECRC- UnsupReq- ACSViol- UEMsk: DLP- SDES- TLP- FCP- CmpltTO- CmpltAbrt- UnxCmplt- RxOF- MalfTLP- ECRC- UnsupReq- ACSViol- UESvrt: DLP+ SDES+ TLP- FCP+ CmpltTO- CmpltAbrt- UnxCmplt- RxOF+ MalfTLP+ ECRC- UnsupReq- ACSViol- CESta: RxErr- BadTLP- BadDLLP- Rollover- Timeout- NonFatalErr+ CEMsk: RxErr- BadTLP- BadDLLP- Rollover- Timeout- NonFatalErr+ AERCap: First Error Pointer: 1f, GenCap+ CGenEn- ChkCap+ ChkEn- Capabilities: [138] Power Budgeting Capabilities: [148] Virtual Channel Capabilities: [448] Vendor Specific Information Capabilities: [950] Vendor Specific Information Kernel driver in use: pcieport 06:01.0 PCI bridge: PLX Technology, Inc. Device 8608 (rev ba) (prog-if 00 [Normal decode]) Control: I/O+ Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- DisINTx+ Status: Cap+ 66MHz- UDF- FastB2B- ParErr- DEVSEL=fast >TAbort- SERR- TAbort- Reset- FastB2B- PriDiscTmr- SecDiscTmr- DiscTmrStat- DiscTmrSERREn- Capabilities: [40] Power Management version 3 Flags: PMEClk- DSI- D1- D2- AuxCurrent=0mA PME(D0+,D1-,D2-,D3hot+,D3cold+) Status: D0 NoSoftRst+ PME-Enable- DSel=0 DScale=0 PME- Capabilities: [48] MSI: Enable+ Count=1/4 Maskable+ 64bit+ Address: 00000000fee00000 Data: 40c1 Masking: 00000001 Pending: 00000000 Capabilities: [68] Express (v2) Downstream Port (Slot+), MSI 00 DevCap: MaxPayload 2048 bytes, PhantFunc 0, Latency L0s <64ns, L1 <1us ExtTag- RBE+ FLReset- DevCtl: Report errors: Correctable- Non-Fatal- Fatal- Unsupported- RlxdOrd- ExtTag- PhantFunc- AuxPwr- NoSnoop- MaxPayload 256 bytes, MaxReadReq 128 bytes DevSta: CorrErr+ UncorrErr- FatalErr- UnsuppReq+ AuxPwr- TransPend- LnkCap: Port #1, Speed 5GT/s, Width x4, ASPM L0s L1, Latency L0 <1us, L1 <2us ClockPM- Surprise+ LLActRep+ BwNot+ LnkCtl: ASPM Disabled; Disabled- Retrain- CommClk- ExtSynch- ClockPM- AutWidDis- BWInt- AutBWInt- LnkSta: Speed 5GT/s, Width x1, TrErr- Train- SlotClk- DLActive+ BWMgmt- ABWMgmt+ SltCap: AttnBtn- PwrCtrl- MRL- AttnInd- PwrInd- HotPlug- Surpise- Slot # 1, PowerLimit 25.000000; Interlock- NoCompl- SltCtl: Enable: AttnBtn- PwrFlt- MRL- PresDet- CmdCplt- HPIrq- LinkChg- Control: AttnInd Off, PwrInd Off, Power- Interlock- SltSta: Status: AttnBtn- PowerFlt- MRL- CmdCplt- PresDet+ Interlock- Changed: MRL- PresDet- LinkState- DevCap2: Completion Timeout: Not Supported, TimeoutDis- ARIFwd+ DevCtl2: Completion Timeout: 50us to 50ms, TimeoutDis- ARIFwd- LnkCtl2: Target Link Speed: 5GT/s, EnterCompliance- SpeedDis-, Selectable De-emphasis: -6dB Transmit Margin: Normal Operating Range, EnterModifiedCompliance- ComplianceSOS- Compliance De-emphasis: -6dB LnkSta2: Current De-emphasis Level: -6dB Capabilities: [a4] Subsystem: Adnaco Technology Inc. Device 0081 Capabilities: [100] Device Serial Number c9-81-17-79-b5-df-0e-00 Capabilities: [fb4] Advanced Error Reporting UESta: DLP- SDES- TLP- FCP- CmpltTO- CmpltAbrt- UnxCmplt- RxOF- MalfTLP- ECRC- UnsupReq- ACSViol- UEMsk: DLP- SDES- TLP- FCP- CmpltTO- CmpltAbrt- UnxCmplt- RxOF- MalfTLP- ECRC- UnsupReq- ACSViol- UESvrt: DLP+ SDES+ TLP- FCP+ CmpltTO- CmpltAbrt- UnxCmplt- RxOF+ MalfTLP+ ECRC- UnsupReq- ACSViol- CESta: RxErr- BadTLP- BadDLLP- Rollover- Timeout- NonFatalErr+ CEMsk: RxErr- BadTLP- BadDLLP- Rollover- Timeout- NonFatalErr+ AERCap: First Error Pointer: 1f, GenCap+ CGenEn- ChkCap+ ChkEn- Capabilities: [148] Virtual Channel Capabilities: [520] Access Control Services ACSCap: SrcValid+ TransBlk+ ReqRedir+ CmpltRedir+ UpstreamFwd+ EgressCtrl+ DirectTrans+ ACSCtl: SrcValid- TransBlk- ReqRedir- CmpltRedir- UpstreamFwd- EgressCtrl- DirectTrans- Capabilities: [950] Vendor Specific Information Kernel driver in use: pcieport 07:00.0 PCI bridge: PLX Technology, Inc. Device 8606 (rev ba) (prog-if 00 [Normal decode]) Control: I/O+ Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- DisINTx+ Status: Cap+ 66MHz- UDF- FastB2B- ParErr- DEVSEL=fast >TAbort- SERR- TAbort- Reset- FastB2B- PriDiscTmr- SecDiscTmr- DiscTmrStat- DiscTmrSERREn- Capabilities: [40] Power Management version 3 Flags: PMEClk- DSI- D1- D2- AuxCurrent=0mA PME(D0+,D1-,D2-,D3hot+,D3cold+) Status: D0 NoSoftRst+ PME-Enable- DSel=0 DScale=0 PME- Capabilities: [48] MSI: Enable+ Count=1/4 Maskable+ 64bit+ Address: 00000000fee00000 Data: 40c9 Masking: 00000001 Pending: 00000000 Capabilities: [68] Express (v2) Upstream Port, MSI 00 DevCap: MaxPayload 512 bytes, PhantFunc 0, Latency L0s <64ns, L1 <1us ExtTag- AttnBtn- AttnInd- PwrInd- RBE+ FLReset-SlotPowerLimit 25.000000W DevCtl: Report errors: Correctable- Non-Fatal- Fatal- Unsupported- RlxdOrd- ExtTag- PhantFunc- AuxPwr- NoSnoop- MaxPayload 256 bytes, MaxReadReq 128 bytes DevSta: CorrErr+ UncorrErr- FatalErr- UnsuppReq+ AuxPwr- TransPend- LnkCap: Port #0, Speed 5GT/s, Width x2, ASPM L0s L1, Latency L0 <1us, L1 <2us ClockPM- Surprise- LLActRep- BwNot- LnkCtl: ASPM Disabled; Disabled- Retrain- CommClk- ExtSynch- ClockPM- AutWidDis- BWInt- AutBWInt- LnkSta: Speed 5GT/s, Width x1, TrErr- Train- SlotClk- DLActive- BWMgmt- ABWMgmt- DevCap2: Completion Timeout: Not Supported, TimeoutDis- DevCtl2: Completion Timeout: 50us to 50ms, TimeoutDis- LnkCtl2: Target Link Speed: 5GT/s, EnterCompliance- SpeedDis-, Selectable De-emphasis: -6dB Transmit Margin: Normal Operating Range, EnterModifiedCompliance- ComplianceSOS- Compliance De-emphasis: -6dB LnkSta2: Current De-emphasis Level: -6dB Capabilities: [a4] Subsystem: Adnaco Technology Inc. Device 0061 Capabilities: [100] Device Serial Number c8-61-03-07-b5-df-0e-00 Capabilities: [fb4] Advanced Error Reporting UESta: DLP- SDES- TLP- FCP- CmpltTO- CmpltAbrt- UnxCmplt- RxOF- MalfTLP- ECRC- UnsupReq- ACSViol- UEMsk: DLP- SDES- TLP- FCP- CmpltTO- CmpltAbrt- UnxCmplt- RxOF- MalfTLP- ECRC- UnsupReq- ACSViol- UESvrt: DLP+ SDES+ TLP- FCP+ CmpltTO- CmpltAbrt- UnxCmplt- RxOF+ MalfTLP+ ECRC- UnsupReq- ACSViol- CESta: RxErr- BadTLP- BadDLLP- Rollover- Timeout- NonFatalErr+ CEMsk: RxErr- BadTLP- BadDLLP- Rollover- Timeout- NonFatalErr+ AERCap: First Error Pointer: 1f, GenCap+ CGenEn- ChkCap+ ChkEn- Capabilities: [138] Power Budgeting Capabilities: [148] Virtual Channel Capabilities: [448] Vendor Specific Information Capabilities: [950] Vendor Specific Information Kernel driver in use: pcieport 08:01.0 PCI bridge: PLX Technology, Inc. Device 8606 (rev ba) (prog-if 00 [Normal decode]) Control: I/O+ Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- DisINTx+ Status: Cap+ 66MHz- UDF- FastB2B- ParErr- DEVSEL=fast >TAbort- SERR- TAbort- Reset- FastB2B- PriDiscTmr- SecDiscTmr- DiscTmrStat- DiscTmrSERREn- Capabilities: [40] Power Management version 3 Flags: PMEClk- DSI- D1- D2- AuxCurrent=0mA PME(D0+,D1-,D2-,D3hot+,D3cold+) Status: D0 NoSoftRst+ PME-Enable- DSel=0 DScale=0 PME- Capabilities: [48] MSI: Enable+ Count=1/4 Maskable+ 64bit+ Address: 00000000fee00000 Data: 4022 Masking: 00000001 Pending: 00000000 Capabilities: [68] Express (v2) Downstream Port (Slot+), MSI 00 DevCap: MaxPayload 512 bytes, PhantFunc 0, Latency L0s <64ns, L1 <1us ExtTag- RBE+ FLReset- DevCtl: Report errors: Correctable- Non-Fatal- Fatal- Unsupported- RlxdOrd- ExtTag- PhantFunc- AuxPwr- NoSnoop- MaxPayload 128 bytes, MaxReadReq 128 bytes DevSta: CorrErr+ UncorrErr- FatalErr- UnsuppReq+ AuxPwr- TransPend- LnkCap: Port #1, Speed 5GT/s, Width x1, ASPM L0s L1, Latency L0 <2us, L1 <4us ClockPM- Surprise+ LLActRep+ BwNot+ LnkCtl: ASPM Disabled; Disabled- Retrain- CommClk- ExtSynch- ClockPM- AutWidDis- BWInt- AutBWInt- LnkSta: Speed 2.5GT/s, Width x0, TrErr- Train- SlotClk- DLActive- BWMgmt- ABWMgmt- SltCap: AttnBtn- PwrCtrl- MRL- AttnInd- PwrInd- HotPlug+ Surpise- Slot # 0, PowerLimit 0.000000; Interlock- NoCompl- SltCtl: Enable: AttnBtn- PwrFlt- MRL- PresDet- CmdCplt- HPIrq- LinkChg- Control: AttnInd Off, PwrInd Off, Power- Interlock- SltSta: Status: AttnBtn- PowerFlt- MRL- CmdCplt- PresDet- Interlock- Changed: MRL- PresDet- LinkState- DevCap2: Completion Timeout: Not Supported, TimeoutDis- ARIFwd+ DevCtl2: Completion Timeout: 50us to 50ms, TimeoutDis- ARIFwd- LnkCtl2: Target Link Speed: 5GT/s, EnterCompliance- SpeedDis-, Selectable De-emphasis: -6dB Transmit Margin: Normal Operating Range, EnterModifiedCompliance- ComplianceSOS- Compliance De-emphasis: -6dB LnkSta2: Current De-emphasis Level: -6dB Capabilities: [a4] Subsystem: Adnaco Technology Inc. Device 0061 Capabilities: [100] Device Serial Number c8-61-03-07-b5-df-0e-00 Capabilities: [fb4] Advanced Error Reporting UESta: DLP- SDES- TLP- FCP- CmpltTO- CmpltAbrt- UnxCmplt- RxOF- MalfTLP- ECRC- UnsupReq- ACSViol- UEMsk: DLP- SDES- TLP- FCP- CmpltTO- CmpltAbrt- UnxCmplt- RxOF- MalfTLP- ECRC- UnsupReq- ACSViol- UESvrt: DLP+ SDES+ TLP- FCP+ CmpltTO- CmpltAbrt- UnxCmplt- RxOF+ MalfTLP+ ECRC- UnsupReq- ACSViol- CESta: RxErr- BadTLP- BadDLLP- Rollover- Timeout- NonFatalErr+ CEMsk: RxErr- BadTLP- BadDLLP- Rollover- Timeout- NonFatalErr+ AERCap: First Error Pointer: 1f, GenCap+ CGenEn- ChkCap+ ChkEn- Capabilities: [148] Virtual Channel Capabilities: [520] Access Control Services ACSCap: SrcValid+ TransBlk+ ReqRedir+ CmpltRedir+ UpstreamFwd+ EgressCtrl+ DirectTrans+ ACSCtl: SrcValid- TransBlk- ReqRedir- CmpltRedir- UpstreamFwd- EgressCtrl- DirectTrans- Capabilities: [950] Vendor Specific Information Kernel driver in use: pcieport 08:05.0 PCI bridge: PLX Technology, Inc. Device 8606 (rev ba) (prog-if 00 [Normal decode]) Control: I/O+ Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- DisINTx+ Status: Cap+ 66MHz- UDF- FastB2B- ParErr- DEVSEL=fast >TAbort- SERR- TAbort- Reset- FastB2B- PriDiscTmr- SecDiscTmr- DiscTmrStat- DiscTmrSERREn- Capabilities: [40] Power Management version 3 Flags: PMEClk- DSI- D1- D2- AuxCurrent=0mA PME(D0+,D1-,D2-,D3hot+,D3cold+) Status: D0 NoSoftRst+ PME-Enable- DSel=0 DScale=0 PME- Capabilities: [48] MSI: Enable+ Count=1/4 Maskable+ 64bit+ Address: 00000000fee00000 Data: 402a Masking: 00000001 Pending: 00000000 Capabilities: [68] Express (v2) Downstream Port (Slot+), MSI 00 DevCap: MaxPayload 512 bytes, PhantFunc 0, Latency L0s <64ns, L1 <1us ExtTag- RBE+ FLReset- DevCtl: Report errors: Correctable- Non-Fatal- Fatal- Unsupported- RlxdOrd- ExtTag- PhantFunc- AuxPwr- NoSnoop- MaxPayload 128 bytes, MaxReadReq 128 bytes DevSta: CorrErr+ UncorrErr- FatalErr- UnsuppReq+ AuxPwr- TransPend- LnkCap: Port #5, Speed 5GT/s, Width x1, ASPM L0s L1, Latency L0 <2us, L1 <4us ClockPM- Surprise+ LLActRep+ BwNot+ LnkCtl: ASPM Disabled; Disabled- Retrain- CommClk- ExtSynch- ClockPM- AutWidDis- BWInt- AutBWInt- LnkSta: Speed 2.5GT/s, Width x0, TrErr- Train- SlotClk- DLActive- BWMgmt- ABWMgmt- SltCap: AttnBtn- PwrCtrl- MRL- AttnInd- PwrInd- HotPlug+ Surpise- Slot # 0, PowerLimit 0.000000; Interlock- NoCompl- SltCtl: Enable: AttnBtn- PwrFlt- MRL- PresDet- CmdCplt- HPIrq- LinkChg- Control: AttnInd Off, PwrInd Off, Power- Interlock- SltSta: Status: AttnBtn- PowerFlt- MRL- CmdCplt- PresDet- Interlock- Changed: MRL- PresDet- LinkState- DevCap2: Completion Timeout: Not Supported, TimeoutDis- ARIFwd+ DevCtl2: Completion Timeout: 50us to 50ms, TimeoutDis- ARIFwd- LnkCtl2: Target Link Speed: 5GT/s, EnterCompliance- SpeedDis-, Selectable De-emphasis: -6dB Transmit Margin: Normal Operating Range, EnterModifiedCompliance- ComplianceSOS- Compliance De-emphasis: -6dB LnkSta2: Current De-emphasis Level: -6dB Capabilities: [a4] Subsystem: Adnaco Technology Inc. Device 0061 Capabilities: [100] Device Serial Number c8-61-03-07-b5-df-0e-00 Capabilities: [fb4] Advanced Error Reporting UESta: DLP- SDES- TLP- FCP- CmpltTO- CmpltAbrt- UnxCmplt- RxOF- MalfTLP- ECRC- UnsupReq- ACSViol- UEMsk: DLP- SDES- TLP- FCP- CmpltTO- CmpltAbrt- UnxCmplt- RxOF- MalfTLP- ECRC- UnsupReq- ACSViol- UESvrt: DLP+ SDES+ TLP- FCP+ CmpltTO- CmpltAbrt- UnxCmplt- RxOF+ MalfTLP+ ECRC- UnsupReq- ACSViol- CESta: RxErr- BadTLP- BadDLLP- Rollover- Timeout- NonFatalErr+ CEMsk: RxErr- BadTLP- BadDLLP- Rollover- Timeout- NonFatalErr+ AERCap: First Error Pointer: 1f, GenCap+ CGenEn- ChkCap+ ChkEn- Capabilities: [148] Virtual Channel Capabilities: [520] Access Control Services ACSCap: SrcValid+ TransBlk+ ReqRedir+ CmpltRedir+ UpstreamFwd+ EgressCtrl+ DirectTrans+ ACSCtl: SrcValid- TransBlk- ReqRedir- CmpltRedir- UpstreamFwd- EgressCtrl- DirectTrans- Capabilities: [950] Vendor Specific Information Kernel driver in use: pcieport 08:07.0 PCI bridge: PLX Technology, Inc. Device 8606 (rev ba) (prog-if 00 [Normal decode]) Control: I/O+ Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- DisINTx+ Status: Cap+ 66MHz- UDF- FastB2B- ParErr- DEVSEL=fast >TAbort- SERR- TAbort- Reset- FastB2B- PriDiscTmr- SecDiscTmr- DiscTmrStat- DiscTmrSERREn- Capabilities: [40] Power Management version 3 Flags: PMEClk- DSI- D1- D2- AuxCurrent=0mA PME(D0+,D1-,D2-,D3hot+,D3cold+) Status: D0 NoSoftRst+ PME-Enable- DSel=0 DScale=0 PME- Capabilities: [48] MSI: Enable+ Count=1/4 Maskable+ 64bit+ Address: 00000000fee00000 Data: 4042 Masking: 00000001 Pending: 00000000 Capabilities: [68] Express (v2) Downstream Port (Slot+), MSI 00 DevCap: MaxPayload 512 bytes, PhantFunc 0, Latency L0s <64ns, L1 <1us ExtTag- RBE+ FLReset- DevCtl: Report errors: Correctable- Non-Fatal- Fatal- Unsupported- RlxdOrd- ExtTag- PhantFunc- AuxPwr- NoSnoop- MaxPayload 128 bytes, MaxReadReq 128 bytes DevSta: CorrErr+ UncorrErr- FatalErr- UnsuppReq+ AuxPwr- TransPend- LnkCap: Port #7, Speed 5GT/s, Width x1, ASPM L0s L1, Latency L0 <2us, L1 <4us ClockPM- Surprise+ LLActRep+ BwNot+ LnkCtl: ASPM Disabled; Disabled- Retrain- CommClk- ExtSynch- ClockPM- AutWidDis- BWInt- AutBWInt- LnkSta: Speed 2.5GT/s, Width x0, TrErr- Train- SlotClk- DLActive- BWMgmt- ABWMgmt- SltCap: AttnBtn- PwrCtrl- MRL- AttnInd- PwrInd- HotPlug+ Surpise- Slot # 0, PowerLimit 0.000000; Interlock- NoCompl- SltCtl: Enable: AttnBtn- PwrFlt- MRL- PresDet- CmdCplt- HPIrq- LinkChg- Control: AttnInd Off, PwrInd Off, Power- Interlock- SltSta: Status: AttnBtn- PowerFlt- MRL- CmdCplt- PresDet- Interlock- Changed: MRL- PresDet- LinkState- DevCap2: Completion Timeout: Not Supported, TimeoutDis- ARIFwd+ DevCtl2: Completion Timeout: 50us to 50ms, TimeoutDis- ARIFwd- LnkCtl2: Target Link Speed: 5GT/s, EnterCompliance- SpeedDis-, Selectable De-emphasis: -6dB Transmit Margin: Normal Operating Range, EnterModifiedCompliance- ComplianceSOS- Compliance De-emphasis: -6dB LnkSta2: Current De-emphasis Level: -6dB Capabilities: [a4] Subsystem: Adnaco Technology Inc. Device 0061 Capabilities: [100] Device Serial Number c8-61-03-07-b5-df-0e-00 Capabilities: [fb4] Advanced Error Reporting UESta: DLP- SDES- TLP- FCP- CmpltTO- CmpltAbrt- UnxCmplt- RxOF- MalfTLP- ECRC- UnsupReq- ACSViol- UEMsk: DLP- SDES- TLP- FCP- CmpltTO- CmpltAbrt- UnxCmplt- RxOF- MalfTLP- ECRC- UnsupReq- ACSViol- UESvrt: DLP+ SDES+ TLP- FCP+ CmpltTO- CmpltAbrt- UnxCmplt- RxOF+ MalfTLP+ ECRC- UnsupReq- ACSViol- CESta: RxErr- BadTLP- BadDLLP- Rollover- Timeout- NonFatalErr+ CEMsk: RxErr- BadTLP- BadDLLP- Rollover- Timeout- NonFatalErr+ AERCap: First Error Pointer: 1f, GenCap+ CGenEn- ChkCap+ ChkEn- Capabilities: [148] Virtual Channel Capabilities: [520] Access Control Services ACSCap: SrcValid+ TransBlk+ ReqRedir+ CmpltRedir+ UpstreamFwd+ EgressCtrl+ DirectTrans+ ACSCtl: SrcValid- TransBlk- ReqRedir- CmpltRedir- UpstreamFwd- EgressCtrl- DirectTrans- Capabilities: [950] Vendor Specific Information Kernel driver in use: pcieport 08:09.0 PCI bridge: PLX Technology, Inc. Device 8606 (rev ba) (prog-if 00 [Normal decode]) Control: I/O+ Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- DisINTx+ Status: Cap+ 66MHz- UDF- FastB2B- ParErr- DEVSEL=fast >TAbort- SERR- TAbort- Reset- FastB2B- PriDiscTmr- SecDiscTmr- DiscTmrStat- DiscTmrSERREn- Capabilities: [40] Power Management version 3 Flags: PMEClk- DSI- D1- D2- AuxCurrent=0mA PME(D0+,D1-,D2-,D3hot+,D3cold+) Status: D0 NoSoftRst+ PME-Enable- DSel=0 DScale=0 PME- Capabilities: [48] MSI: Enable+ Count=1/4 Maskable+ 64bit+ Address: 00000000fee00000 Data: 404a Masking: 00000001 Pending: 00000000 Capabilities: [68] Express (v2) Downstream Port (Slot+), MSI 00 DevCap: MaxPayload 512 bytes, PhantFunc 0, Latency L0s <64ns, L1 <1us ExtTag- RBE+ FLReset- DevCtl: Report errors: Correctable- Non-Fatal- Fatal- Unsupported- RlxdOrd- ExtTag- PhantFunc- AuxPwr- NoSnoop- MaxPayload 256 bytes, MaxReadReq 128 bytes DevSta: CorrErr+ UncorrErr- FatalErr- UnsuppReq+ AuxPwr- TransPend- LnkCap: Port #9, Speed 5GT/s, Width x1, ASPM L0s L1, Latency L0 <1us, L1 <2us ClockPM- Surprise+ LLActRep+ BwNot+ LnkCtl: ASPM Disabled; Disabled- Retrain- CommClk- ExtSynch- ClockPM- AutWidDis- BWInt- AutBWInt- LnkSta: Speed 5GT/s, Width x1, TrErr- Train- SlotClk- DLActive+ BWMgmt- ABWMgmt+ SltCap: AttnBtn- PwrCtrl- MRL- AttnInd- PwrInd- HotPlug+ Surpise- Slot # 0, PowerLimit 0.000000; Interlock- NoCompl- SltCtl: Enable: AttnBtn- PwrFlt- MRL- PresDet- CmdCplt- HPIrq- LinkChg- Control: AttnInd Off, PwrInd Off, Power- Interlock- SltSta: Status: AttnBtn- PowerFlt- MRL- CmdCplt- PresDet+ Interlock- Changed: MRL- PresDet- LinkState- DevCap2: Completion Timeout: Not Supported, TimeoutDis- ARIFwd+ DevCtl2: Completion Timeout: 50us to 50ms, TimeoutDis- ARIFwd- LnkCtl2: Target Link Speed: 5GT/s, EnterCompliance- SpeedDis-, Selectable De-emphasis: -6dB Transmit Margin: Normal Operating Range, EnterModifiedCompliance- ComplianceSOS- Compliance De-emphasis: -6dB LnkSta2: Current De-emphasis Level: -6dB Capabilities: [a4] Subsystem: Adnaco Technology Inc. Device 0061 Capabilities: [100] Device Serial Number c8-61-03-07-b5-df-0e-00 Capabilities: [fb4] Advanced Error Reporting UESta: DLP- SDES- TLP- FCP- CmpltTO- CmpltAbrt- UnxCmplt- RxOF- MalfTLP- ECRC- UnsupReq- ACSViol- UEMsk: DLP- SDES- TLP- FCP- CmpltTO- CmpltAbrt- UnxCmplt- RxOF- MalfTLP- ECRC- UnsupReq- ACSViol- UESvrt: DLP+ SDES+ TLP- FCP+ CmpltTO- CmpltAbrt- UnxCmplt- RxOF+ MalfTLP+ ECRC- UnsupReq- ACSViol- CESta: RxErr- BadTLP- BadDLLP- Rollover- Timeout- NonFatalErr+ CEMsk: RxErr- BadTLP- BadDLLP- Rollover- Timeout- NonFatalErr+ AERCap: First Error Pointer: 1f, GenCap+ CGenEn- ChkCap+ ChkEn- Capabilities: [148] Virtual Channel Capabilities: [520] Access Control Services ACSCap: SrcValid+ TransBlk+ ReqRedir+ CmpltRedir+ UpstreamFwd+ EgressCtrl+ DirectTrans+ ACSCtl: SrcValid- TransBlk- ReqRedir- CmpltRedir- UpstreamFwd- EgressCtrl- DirectTrans- Capabilities: [950] Vendor Specific Information Kernel driver in use: pcieport 0c:00.0 PCI bridge: Integrated Device Technology, Inc. Device 8091 (rev 02) (prog-if 00 [Normal decode]) Control: I/O+ Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- DisINTx- Status: Cap+ 66MHz- UDF- FastB2B- ParErr- DEVSEL=fast >TAbort- SERR- TAbort- Reset- FastB2B- PriDiscTmr- SecDiscTmr- DiscTmrStat- DiscTmrSERREn- Capabilities: [40] Express (v2) Upstream Port, MSI 00 DevCap: MaxPayload 2048 bytes, PhantFunc 0, Latency L0s <64ns, L1 <1us ExtTag+ AttnBtn- AttnInd- PwrInd- RBE+ FLReset-SlotPowerLimit 0.000000W DevCtl: Report errors: Correctable- Non-Fatal- Fatal- Unsupported- RlxdOrd- ExtTag- PhantFunc- AuxPwr- NoSnoop- MaxPayload 256 bytes, MaxReadReq 128 bytes DevSta: CorrErr+ UncorrErr- FatalErr- UnsuppReq+ AuxPwr- TransPend- LnkCap: Port #0, Speed 5GT/s, Width x8, ASPM L0s L1, Latency L0 <4us, L1 <4us ClockPM- Surprise- LLActRep- BwNot- LnkCtl: ASPM Disabled; Disabled- Retrain- CommClk- ExtSynch- ClockPM- AutWidDis- BWInt- AutBWInt- LnkSta: Speed 5GT/s, Width x1, TrErr- Train- SlotClk- DLActive- BWMgmt- ABWMgmt- DevCap2: Completion Timeout: Not Supported, TimeoutDis- DevCtl2: Completion Timeout: 50us to 50ms, TimeoutDis- LnkCtl2: Target Link Speed: 5GT/s, EnterCompliance- SpeedDis-, Selectable De-emphasis: -6dB Transmit Margin: Normal Operating Range, EnterModifiedCompliance- ComplianceSOS- Compliance De-emphasis: -6dB LnkSta2: Current De-emphasis Level: -6dB Capabilities: [c0] Power Management version 3 Flags: PMEClk- DSI- D1- D2- AuxCurrent=0mA PME(D0+,D1-,D2-,D3hot+,D3cold+) Status: D0 NoSoftRst+ PME-Enable- DSel=0 DScale=0 PME- Capabilities: [f0] Subsystem: Dolphin Interconnect Solutions AS Device 0611 Capabilities: [100] Advanced Error Reporting UESta: DLP- SDES- TLP- FCP- CmpltTO- CmpltAbrt- UnxCmplt- RxOF- MalfTLP- ECRC- UnsupReq- ACSViol- UEMsk: DLP- SDES- TLP- FCP- CmpltTO- CmpltAbrt- UnxCmplt- RxOF- MalfTLP- ECRC- UnsupReq- ACSViol- UESvrt: DLP+ SDES+ TLP- FCP+ CmpltTO- CmpltAbrt- UnxCmplt- RxOF+ MalfTLP+ ECRC- UnsupReq- ACSViol- CESta: RxErr- BadTLP- BadDLLP- Rollover- Timeout- NonFatalErr+ CEMsk: RxErr- BadTLP- BadDLLP- Rollover- Timeout- NonFatalErr+ AERCap: First Error Pointer: 00, GenCap+ CGenEn- ChkCap+ ChkEn- Capabilities: [180] Device Serial Number 00-00-43-45-00-00-09-28 Capabilities: [200] Virtual Channel Capabilities: [330] #12 Kernel driver in use: pcieport 0c:00.1 Bridge: Integrated Device Technology, Inc. Device 8091 (rev 02) Subsystem: Dolphin Interconnect Solutions AS Device 1611 Control: I/O+ Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- DisINTx+ Status: Cap+ 66MHz- UDF- FastB2B- ParErr- DEVSEL=fast >TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- Reset- FastB2B- PriDiscTmr- SecDiscTmr- DiscTmrStat- DiscTmrSERREn- Capabilities: [40] Power Management version 3 Flags: PMEClk- DSI- D1- D2- AuxCurrent=0mA PME(D0+,D1-,D2-,D3hot+,D3cold+) Status: D0 NoSoftRst+ PME-Enable- DSel=0 DScale=0 PME- Capabilities: [48] MSI: Enable+ Count=1/4 Maskable+ 64bit+ Address: 00000000fee00000 Data: 4052 Masking: 00000001 Pending: 00000000 Capabilities: [68] Express (v2) Upstream Port, MSI 00 DevCap: MaxPayload 2048 bytes, PhantFunc 0, Latency L0s <64ns, L1 <1us ExtTag- AttnBtn- AttnInd- PwrInd- RBE+ FLReset-SlotPowerLimit 25.000000W DevCtl: Report errors: Correctable- Non-Fatal- Fatal- Unsupported- RlxdOrd- ExtTag- PhantFunc- AuxPwr- NoSnoop- MaxPayload 256 bytes, MaxReadReq 128 bytes DevSta: CorrErr+ UncorrErr- FatalErr- UnsuppReq+ AuxPwr- TransPend- LnkCap: Port #0, Speed 5GT/s, Width x4, ASPM L0s L1, Latency L0 <1us, L1 <2us ClockPM- Surprise- LLActRep- BwNot- LnkCtl: ASPM Disabled; Disabled- Retrain- CommClk- ExtSynch- ClockPM- AutWidDis- BWInt- AutBWInt- LnkSta: Speed 5GT/s, Width x1, TrErr- Train- SlotClk- DLActive- BWMgmt- ABWMgmt- DevCap2: Completion Timeout: Not Supported, TimeoutDis- DevCtl2: Completion Timeout: 50us to 50ms, TimeoutDis- LnkCtl2: Target Link Speed: 5GT/s, EnterCompliance- SpeedDis-, Selectable De-emphasis: -6dB Transmit Margin: Normal Operating Range, EnterModifiedCompliance- ComplianceSOS- Compliance De-emphasis: -6dB LnkSta2: Current De-emphasis Level: -6dB Capabilities: [a4] Subsystem: Adnaco Technology Inc. Device 0081 Capabilities: [100] Device Serial Number c9-81-17-76-b5-df-0e-00 Capabilities: [fb4] Advanced Error Reporting UESta: DLP- SDES- TLP- FCP- CmpltTO- CmpltAbrt- UnxCmplt- RxOF- MalfTLP- ECRC- UnsupReq- ACSViol- UEMsk: DLP- SDES- TLP- FCP- CmpltTO- CmpltAbrt- UnxCmplt- RxOF- MalfTLP- ECRC- UnsupReq- ACSViol- UESvrt: DLP+ SDES+ TLP- FCP+ CmpltTO- CmpltAbrt- UnxCmplt- RxOF+ MalfTLP+ ECRC- UnsupReq- ACSViol- CESta: RxErr- BadTLP- BadDLLP- Rollover- Timeout- NonFatalErr+ CEMsk: RxErr- BadTLP- BadDLLP- Rollover- Timeout- NonFatalErr+ AERCap: First Error Pointer: 1f, GenCap+ CGenEn- ChkCap+ ChkEn- Capabilities: [138] Power Budgeting Capabilities: [148] Virtual Channel Capabilities: [448] Vendor Specific Information Capabilities: [950] Vendor Specific Information Kernel driver in use: pcieport 0f:01.0 PCI bridge: PLX Technology, Inc. Device 8608 (rev ba) (prog-if 00 [Normal decode]) Control: I/O+ Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- DisINTx+ Status: Cap+ 66MHz- UDF- FastB2B- ParErr- DEVSEL=fast >TAbort- SERR- TAbort- Reset- FastB2B- PriDiscTmr- SecDiscTmr- DiscTmrStat- DiscTmrSERREn- Capabilities: [40] Power Management version 3 Flags: PMEClk- DSI- D1- D2- AuxCurrent=0mA PME(D0+,D1-,D2-,D3hot+,D3cold+) Status: D0 NoSoftRst+ PME-Enable- DSel=0 DScale=0 PME- Capabilities: [48] MSI: Enable+ Count=1/4 Maskable+ 64bit+ Address: 00000000fee00000 Data: 405a Masking: 00000001 Pending: 00000000 Capabilities: [68] Express (v2) Downstream Port (Slot+), MSI 00 DevCap: MaxPayload 2048 bytes, PhantFunc 0, Latency L0s <64ns, L1 <1us ExtTag- RBE+ FLReset- DevCtl: Report errors: Correctable- Non-Fatal- Fatal- Unsupported- RlxdOrd- ExtTag- PhantFunc- AuxPwr- NoSnoop- MaxPayload 256 bytes, MaxReadReq 128 bytes DevSta: CorrErr+ UncorrErr- FatalErr- UnsuppReq+ AuxPwr- TransPend- LnkCap: Port #1, Speed 5GT/s, Width x4, ASPM L0s L1, Latency L0 <1us, L1 <2us ClockPM- Surprise+ LLActRep+ BwNot+ LnkCtl: ASPM Disabled; Disabled- Retrain- CommClk- ExtSynch- ClockPM- AutWidDis- BWInt- AutBWInt- LnkSta: Speed 5GT/s, Width x1, TrErr- Train- SlotClk- DLActive+ BWMgmt- ABWMgmt+ SltCap: AttnBtn- PwrCtrl- MRL- AttnInd- PwrInd- HotPlug- Surpise- Slot # 1, PowerLimit 25.000000; Interlock- NoCompl- SltCtl: Enable: AttnBtn- PwrFlt- MRL- PresDet- CmdCplt- HPIrq- LinkChg- Control: AttnInd Off, PwrInd Off, Power- Interlock- SltSta: Status: AttnBtn- PowerFlt- MRL- CmdCplt- PresDet+ Interlock- Changed: MRL- PresDet- LinkState- DevCap2: Completion Timeout: Not Supported, TimeoutDis- ARIFwd+ DevCtl2: Completion Timeout: 50us to 50ms, TimeoutDis- ARIFwd- LnkCtl2: Target Link Speed: 5GT/s, EnterCompliance- SpeedDis-, Selectable De-emphasis: -6dB Transmit Margin: Normal Operating Range, EnterModifiedCompliance- ComplianceSOS- Compliance De-emphasis: -6dB LnkSta2: Current De-emphasis Level: -6dB Capabilities: [a4] Subsystem: Adnaco Technology Inc. Device 0081 Capabilities: [100] Device Serial Number c9-81-17-76-b5-df-0e-00 Capabilities: [fb4] Advanced Error Reporting UESta: DLP- SDES- TLP- FCP- CmpltTO- CmpltAbrt- UnxCmplt- RxOF- MalfTLP- ECRC- UnsupReq- ACSViol- UEMsk: DLP- SDES- TLP- FCP- CmpltTO- CmpltAbrt- UnxCmplt- RxOF- MalfTLP- ECRC- UnsupReq- ACSViol- UESvrt: DLP+ SDES+ TLP- FCP+ CmpltTO- CmpltAbrt- UnxCmplt- RxOF+ MalfTLP+ ECRC- UnsupReq- ACSViol- CESta: RxErr- BadTLP- BadDLLP- Rollover- Timeout- NonFatalErr+ CEMsk: RxErr- BadTLP- BadDLLP- Rollover- Timeout- NonFatalErr+ AERCap: First Error Pointer: 1f, GenCap+ CGenEn- ChkCap+ ChkEn- Capabilities: [148] Virtual Channel Capabilities: [520] Access Control Services ACSCap: SrcValid+ TransBlk+ ReqRedir+ CmpltRedir+ UpstreamFwd+ EgressCtrl+ DirectTrans+ ACSCtl: SrcValid- TransBlk- ReqRedir- CmpltRedir- UpstreamFwd- EgressCtrl- DirectTrans- Capabilities: [950] Vendor Specific Information Kernel driver in use: pcieport 10:00.0 PCI bridge: PLX Technology, Inc. Device 8606 (rev ba) (prog-if 00 [Normal decode]) Control: I/O+ Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- DisINTx+ Status: Cap+ 66MHz- UDF- FastB2B- ParErr- DEVSEL=fast >TAbort- SERR- TAbort- Reset- FastB2B- PriDiscTmr- SecDiscTmr- DiscTmrStat- DiscTmrSERREn- Capabilities: [40] Power Management version 3 Flags: PMEClk- DSI- D1- D2- AuxCurrent=0mA PME(D0+,D1-,D2-,D3hot+,D3cold+) Status: D0 NoSoftRst+ PME-Enable- DSel=0 DScale=0 PME- Capabilities: [48] MSI: Enable+ Count=1/4 Maskable+ 64bit+ Address: 00000000fee00000 Data: 4062 Masking: 00000001 Pending: 00000000 Capabilities: [68] Express (v2) Upstream Port, MSI 00 DevCap: MaxPayload 512 bytes, PhantFunc 0, Latency L0s <64ns, L1 <1us ExtTag- AttnBtn- AttnInd- PwrInd- RBE+ FLReset-SlotPowerLimit 25.000000W DevCtl: Report errors: Correctable- Non-Fatal- Fatal- Unsupported- RlxdOrd- ExtTag- PhantFunc- AuxPwr- NoSnoop- MaxPayload 256 bytes, MaxReadReq 128 bytes DevSta: CorrErr+ UncorrErr- FatalErr- UnsuppReq+ AuxPwr- TransPend- LnkCap: Port #0, Speed 5GT/s, Width x2, ASPM L0s L1, Latency L0 <1us, L1 <2us ClockPM- Surprise- LLActRep- BwNot- LnkCtl: ASPM Disabled; Disabled- Retrain- CommClk- ExtSynch- ClockPM- AutWidDis- BWInt- AutBWInt- LnkSta: Speed 5GT/s, Width x1, TrErr- Train- SlotClk- DLActive- BWMgmt- ABWMgmt- DevCap2: Completion Timeout: Not Supported, TimeoutDis- DevCtl2: Completion Timeout: 50us to 50ms, TimeoutDis- LnkCtl2: Target Link Speed: 5GT/s, EnterCompliance- SpeedDis-, Selectable De-emphasis: -6dB Transmit Margin: Normal Operating Range, EnterModifiedCompliance- ComplianceSOS- Compliance De-emphasis: -6dB LnkSta2: Current De-emphasis Level: -6dB Capabilities: [a4] Subsystem: Adnaco Technology Inc. Device 0061 Capabilities: [100] Device Serial Number c8-61-03-23-b5-df-0e-00 Capabilities: [fb4] Advanced Error Reporting UESta: DLP- SDES- TLP- FCP- CmpltTO- CmpltAbrt- UnxCmplt- RxOF- MalfTLP- ECRC- UnsupReq- ACSViol- UEMsk: DLP- SDES- TLP- FCP- CmpltTO- CmpltAbrt- UnxCmplt- RxOF- MalfTLP- ECRC- UnsupReq- ACSViol- UESvrt: DLP+ SDES+ TLP- FCP+ CmpltTO- CmpltAbrt- UnxCmplt- RxOF+ MalfTLP+ ECRC- UnsupReq- ACSViol- CESta: RxErr- BadTLP- BadDLLP- Rollover- Timeout- NonFatalErr+ CEMsk: RxErr- BadTLP- BadDLLP- Rollover- Timeout- NonFatalErr+ AERCap: First Error Pointer: 1f, GenCap+ CGenEn- ChkCap+ ChkEn- Capabilities: [138] Power Budgeting Capabilities: [148] Virtual Channel Capabilities: [448] Vendor Specific Information Capabilities: [950] Vendor Specific Information Kernel driver in use: pcieport 11:01.0 PCI bridge: PLX Technology, Inc. Device 8606 (rev ba) (prog-if 00 [Normal decode]) Control: I/O+ Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- DisINTx+ Status: Cap+ 66MHz- UDF- FastB2B- ParErr- DEVSEL=fast >TAbort- SERR- TAbort- Reset- FastB2B- PriDiscTmr- SecDiscTmr- DiscTmrStat- DiscTmrSERREn- Capabilities: [40] Power Management version 3 Flags: PMEClk- DSI- D1- D2- AuxCurrent=0mA PME(D0+,D1-,D2-,D3hot+,D3cold+) Status: D0 NoSoftRst+ PME-Enable- DSel=0 DScale=0 PME- Capabilities: [48] MSI: Enable+ Count=1/4 Maskable+ 64bit+ Address: 00000000fee00000 Data: 406a Masking: 00000001 Pending: 00000000 Capabilities: [68] Express (v2) Downstream Port (Slot+), MSI 00 DevCap: MaxPayload 512 bytes, PhantFunc 0, Latency L0s <64ns, L1 <1us ExtTag- RBE+ FLReset- DevCtl: Report errors: Correctable- Non-Fatal- Fatal- Unsupported- RlxdOrd- ExtTag- PhantFunc- AuxPwr- NoSnoop- MaxPayload 128 bytes, MaxReadReq 128 bytes DevSta: CorrErr+ UncorrErr- FatalErr- UnsuppReq+ AuxPwr- TransPend- LnkCap: Port #1, Speed 5GT/s, Width x1, ASPM L0s L1, Latency L0 <2us, L1 <4us ClockPM- Surprise+ LLActRep+ BwNot+ LnkCtl: ASPM Disabled; Disabled- Retrain- CommClk- ExtSynch- ClockPM- AutWidDis- BWInt- AutBWInt- LnkSta: Speed 2.5GT/s, Width x0, TrErr- Train- SlotClk- DLActive- BWMgmt- ABWMgmt- SltCap: AttnBtn- PwrCtrl- MRL- AttnInd- PwrInd- HotPlug+ Surpise- Slot # 0, PowerLimit 0.000000; Interlock- NoCompl- SltCtl: Enable: AttnBtn- PwrFlt- MRL- PresDet- CmdCplt- HPIrq- LinkChg- Control: AttnInd Off, PwrInd Off, Power- Interlock- SltSta: Status: AttnBtn- PowerFlt- MRL- CmdCplt- PresDet- Interlock- Changed: MRL- PresDet- LinkState- DevCap2: Completion Timeout: Not Supported, TimeoutDis- ARIFwd+ DevCtl2: Completion Timeout: 50us to 50ms, TimeoutDis- ARIFwd- LnkCtl2: Target Link Speed: 5GT/s, EnterCompliance- SpeedDis-, Selectable De-emphasis: -6dB Transmit Margin: Normal Operating Range, EnterModifiedCompliance- ComplianceSOS- Compliance De-emphasis: -6dB LnkSta2: Current De-emphasis Level: -6dB Capabilities: [a4] Subsystem: Adnaco Technology Inc. Device 0061 Capabilities: [100] Device Serial Number c8-61-03-23-b5-df-0e-00 Capabilities: [fb4] Advanced Error Reporting UESta: DLP- SDES- TLP- FCP- CmpltTO- CmpltAbrt- UnxCmplt- RxOF- MalfTLP- ECRC- UnsupReq- ACSViol- UEMsk: DLP- SDES- TLP- FCP- CmpltTO- CmpltAbrt- UnxCmplt- RxOF- MalfTLP- ECRC- UnsupReq- ACSViol- UESvrt: DLP+ SDES+ TLP- FCP+ CmpltTO- CmpltAbrt- UnxCmplt- RxOF+ MalfTLP+ ECRC- UnsupReq- ACSViol- CESta: RxErr- BadTLP- BadDLLP- Rollover- Timeout- NonFatalErr+ CEMsk: RxErr- BadTLP- BadDLLP- Rollover- Timeout- NonFatalErr+ AERCap: First Error Pointer: 1f, GenCap+ CGenEn- ChkCap+ ChkEn- Capabilities: [148] Virtual Channel Capabilities: [520] Access Control Services ACSCap: SrcValid+ TransBlk+ ReqRedir+ CmpltRedir+ UpstreamFwd+ EgressCtrl+ DirectTrans+ ACSCtl: SrcValid- TransBlk- ReqRedir- CmpltRedir- UpstreamFwd- EgressCtrl- DirectTrans- Capabilities: [950] Vendor Specific Information Kernel driver in use: pcieport 11:05.0 PCI bridge: PLX Technology, Inc. Device 8606 (rev ba) (prog-if 00 [Normal decode]) Control: I/O+ Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- DisINTx+ Status: Cap+ 66MHz- UDF- FastB2B- ParErr- DEVSEL=fast >TAbort- SERR- TAbort- Reset- FastB2B- PriDiscTmr- SecDiscTmr- DiscTmrStat- DiscTmrSERREn- Capabilities: [40] Power Management version 3 Flags: PMEClk- DSI- D1- D2- AuxCurrent=0mA PME(D0+,D1-,D2-,D3hot+,D3cold+) Status: D0 NoSoftRst+ PME-Enable- DSel=0 DScale=0 PME- Capabilities: [48] MSI: Enable+ Count=1/4 Maskable+ 64bit+ Address: 00000000fee00000 Data: 4072 Masking: 00000001 Pending: 00000000 Capabilities: [68] Express (v2) Downstream Port (Slot+), MSI 00 DevCap: MaxPayload 512 bytes, PhantFunc 0, Latency L0s <64ns, L1 <1us ExtTag- RBE+ FLReset- DevCtl: Report errors: Correctable- Non-Fatal- Fatal- Unsupported- RlxdOrd- ExtTag- PhantFunc- AuxPwr- NoSnoop- MaxPayload 128 bytes, MaxReadReq 128 bytes DevSta: CorrErr+ UncorrErr- FatalErr- UnsuppReq+ AuxPwr- TransPend- LnkCap: Port #5, Speed 5GT/s, Width x1, ASPM L0s L1, Latency L0 <2us, L1 <4us ClockPM- Surprise+ LLActRep+ BwNot+ LnkCtl: ASPM Disabled; Disabled- Retrain- CommClk- ExtSynch- ClockPM- AutWidDis- BWInt- AutBWInt- LnkSta: Speed 2.5GT/s, Width x0, TrErr- Train- SlotClk- DLActive- BWMgmt- ABWMgmt- SltCap: AttnBtn- PwrCtrl- MRL- AttnInd- PwrInd- HotPlug+ Surpise- Slot # 0, PowerLimit 0.000000; Interlock- NoCompl- SltCtl: Enable: AttnBtn- PwrFlt- MRL- PresDet- CmdCplt- HPIrq- LinkChg- Control: AttnInd Off, PwrInd Off, Power- Interlock- SltSta: Status: AttnBtn- PowerFlt- MRL- CmdCplt- PresDet- Interlock- Changed: MRL- PresDet- LinkState- DevCap2: Completion Timeout: Not Supported, TimeoutDis- ARIFwd+ DevCtl2: Completion Timeout: 50us to 50ms, TimeoutDis- ARIFwd- LnkCtl2: Target Link Speed: 5GT/s, EnterCompliance- SpeedDis-, Selectable De-emphasis: -6dB Transmit Margin: Normal Operating Range, EnterModifiedCompliance- ComplianceSOS- Compliance De-emphasis: -6dB LnkSta2: Current De-emphasis Level: -6dB Capabilities: [a4] Subsystem: Adnaco Technology Inc. Device 0061 Capabilities: [100] Device Serial Number c8-61-03-23-b5-df-0e-00 Capabilities: [fb4] Advanced Error Reporting UESta: DLP- SDES- TLP- FCP- CmpltTO- CmpltAbrt- UnxCmplt- RxOF- MalfTLP- ECRC- UnsupReq- ACSViol- UEMsk: DLP- SDES- TLP- FCP- CmpltTO- CmpltAbrt- UnxCmplt- RxOF- MalfTLP- ECRC- UnsupReq- ACSViol- UESvrt: DLP+ SDES+ TLP- FCP+ CmpltTO- CmpltAbrt- UnxCmplt- RxOF+ MalfTLP+ ECRC- UnsupReq- ACSViol- CESta: RxErr- BadTLP- BadDLLP- Rollover- Timeout- NonFatalErr+ CEMsk: RxErr- BadTLP- BadDLLP- Rollover- Timeout- NonFatalErr+ AERCap: First Error Pointer: 1f, GenCap+ CGenEn- ChkCap+ ChkEn- Capabilities: [148] Virtual Channel Capabilities: [520] Access Control Services ACSCap: SrcValid+ TransBlk+ ReqRedir+ CmpltRedir+ UpstreamFwd+ EgressCtrl+ DirectTrans+ ACSCtl: SrcValid- TransBlk- ReqRedir- CmpltRedir- UpstreamFwd- EgressCtrl- DirectTrans- Capabilities: [950] Vendor Specific Information Kernel driver in use: pcieport 11:07.0 PCI bridge: PLX Technology, Inc. Device 8606 (rev ba) (prog-if 00 [Normal decode]) Control: I/O+ Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- DisINTx+ Status: Cap+ 66MHz- UDF- FastB2B- ParErr- DEVSEL=fast >TAbort- SERR- TAbort- Reset- FastB2B- PriDiscTmr- SecDiscTmr- DiscTmrStat- DiscTmrSERREn- Capabilities: [40] Power Management version 3 Flags: PMEClk- DSI- D1- D2- AuxCurrent=0mA PME(D0+,D1-,D2-,D3hot+,D3cold+) Status: D0 NoSoftRst+ PME-Enable- DSel=0 DScale=0 PME- Capabilities: [48] MSI: Enable+ Count=1/4 Maskable+ 64bit+ Address: 00000000fee00000 Data: 407a Masking: 00000001 Pending: 00000000 Capabilities: [68] Express (v2) Downstream Port (Slot+), MSI 00 DevCap: MaxPayload 512 bytes, PhantFunc 0, Latency L0s <64ns, L1 <1us ExtTag- RBE+ FLReset- DevCtl: Report errors: Correctable- Non-Fatal- Fatal- Unsupported- RlxdOrd- ExtTag- PhantFunc- AuxPwr- NoSnoop- MaxPayload 128 bytes, MaxReadReq 128 bytes DevSta: CorrErr+ UncorrErr- FatalErr- UnsuppReq+ AuxPwr- TransPend- LnkCap: Port #7, Speed 5GT/s, Width x1, ASPM L0s L1, Latency L0 <2us, L1 <4us ClockPM- Surprise+ LLActRep+ BwNot+ LnkCtl: ASPM Disabled; Disabled- Retrain- CommClk- ExtSynch- ClockPM- AutWidDis- BWInt- AutBWInt- LnkSta: Speed 2.5GT/s, Width x0, TrErr- Train- SlotClk- DLActive- BWMgmt- ABWMgmt- SltCap: AttnBtn- PwrCtrl- MRL- AttnInd- PwrInd- HotPlug+ Surpise- Slot # 0, PowerLimit 0.000000; Interlock- NoCompl- SltCtl: Enable: AttnBtn- PwrFlt- MRL- PresDet- CmdCplt- HPIrq- LinkChg- Control: AttnInd Off, PwrInd Off, Power- Interlock- SltSta: Status: AttnBtn- PowerFlt- MRL- CmdCplt- PresDet- Interlock- Changed: MRL- PresDet- LinkState- DevCap2: Completion Timeout: Not Supported, TimeoutDis- ARIFwd+ DevCtl2: Completion Timeout: 50us to 50ms, TimeoutDis- ARIFwd- LnkCtl2: Target Link Speed: 5GT/s, EnterCompliance- SpeedDis-, Selectable De-emphasis: -6dB Transmit Margin: Normal Operating Range, EnterModifiedCompliance- ComplianceSOS- Compliance De-emphasis: -6dB LnkSta2: Current De-emphasis Level: -6dB Capabilities: [a4] Subsystem: Adnaco Technology Inc. Device 0061 Capabilities: [100] Device Serial Number c8-61-03-23-b5-df-0e-00 Capabilities: [fb4] Advanced Error Reporting UESta: DLP- SDES- TLP- FCP- CmpltTO- CmpltAbrt- UnxCmplt- RxOF- MalfTLP- ECRC- UnsupReq- ACSViol- UEMsk: DLP- SDES- TLP- FCP- CmpltTO- CmpltAbrt- UnxCmplt- RxOF- MalfTLP- ECRC- UnsupReq- ACSViol- UESvrt: DLP+ SDES+ TLP- FCP+ CmpltTO- CmpltAbrt- UnxCmplt- RxOF+ MalfTLP+ ECRC- UnsupReq- ACSViol- CESta: RxErr- BadTLP- BadDLLP- Rollover- Timeout- NonFatalErr+ CEMsk: RxErr- BadTLP- BadDLLP- Rollover- Timeout- NonFatalErr+ AERCap: First Error Pointer: 1f, GenCap+ CGenEn- ChkCap+ ChkEn- Capabilities: [148] Virtual Channel Capabilities: [520] Access Control Services ACSCap: SrcValid+ TransBlk+ ReqRedir+ CmpltRedir+ UpstreamFwd+ EgressCtrl+ DirectTrans+ ACSCtl: SrcValid- TransBlk- ReqRedir- CmpltRedir- UpstreamFwd- EgressCtrl- DirectTrans- Capabilities: [950] Vendor Specific Information Kernel driver in use: pcieport 11:09.0 PCI bridge: PLX Technology, Inc. Device 8606 (rev ba) (prog-if 00 [Normal decode]) Control: I/O+ Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- DisINTx+ Status: Cap+ 66MHz- UDF- FastB2B- ParErr- DEVSEL=fast >TAbort- SERR- TAbort- Reset- FastB2B- PriDiscTmr- SecDiscTmr- DiscTmrStat- DiscTmrSERREn- Capabilities: [40] Power Management version 3 Flags: PMEClk- DSI- D1- D2- AuxCurrent=0mA PME(D0+,D1-,D2-,D3hot+,D3cold+) Status: D0 NoSoftRst+ PME-Enable- DSel=0 DScale=0 PME- Capabilities: [48] MSI: Enable+ Count=1/4 Maskable+ 64bit+ Address: 00000000fee00000 Data: 4082 Masking: 00000001 Pending: 00000000 Capabilities: [68] Express (v2) Downstream Port (Slot+), MSI 00 DevCap: MaxPayload 512 bytes, PhantFunc 0, Latency L0s <64ns, L1 <1us ExtTag- RBE+ FLReset- DevCtl: Report errors: Correctable- Non-Fatal- Fatal- Unsupported- RlxdOrd- ExtTag- PhantFunc- AuxPwr- NoSnoop- MaxPayload 256 bytes, MaxReadReq 128 bytes DevSta: CorrErr+ UncorrErr- FatalErr- UnsuppReq+ AuxPwr- TransPend- LnkCap: Port #9, Speed 5GT/s, Width x1, ASPM L0s L1, Latency L0 <1us, L1 <2us ClockPM- Surprise+ LLActRep+ BwNot+ LnkCtl: ASPM Disabled; Disabled- Retrain- CommClk- ExtSynch- ClockPM- AutWidDis- BWInt- AutBWInt- LnkSta: Speed 5GT/s, Width x1, TrErr- Train- SlotClk- DLActive+ BWMgmt- ABWMgmt+ SltCap: AttnBtn- PwrCtrl- MRL- AttnInd- PwrInd- HotPlug+ Surpise- Slot # 0, PowerLimit 0.000000; Interlock- NoCompl- SltCtl: Enable: AttnBtn- PwrFlt- MRL- PresDet- CmdCplt- HPIrq- LinkChg- Control: AttnInd Off, PwrInd Off, Power- Interlock- SltSta: Status: AttnBtn- PowerFlt- MRL- CmdCplt- PresDet+ Interlock- Changed: MRL- PresDet- LinkState- DevCap2: Completion Timeout: Not Supported, TimeoutDis- ARIFwd+ DevCtl2: Completion Timeout: 50us to 50ms, TimeoutDis- ARIFwd- LnkCtl2: Target Link Speed: 5GT/s, EnterCompliance- SpeedDis-, Selectable De-emphasis: -6dB Transmit Margin: Normal Operating Range, EnterModifiedCompliance- ComplianceSOS- Compliance De-emphasis: -6dB LnkSta2: Current De-emphasis Level: -6dB Capabilities: [a4] Subsystem: Adnaco Technology Inc. Device 0061 Capabilities: [100] Device Serial Number c8-61-03-23-b5-df-0e-00 Capabilities: [fb4] Advanced Error Reporting UESta: DLP- SDES- TLP- FCP- CmpltTO- CmpltAbrt- UnxCmplt- RxOF- MalfTLP- ECRC- UnsupReq- ACSViol- UEMsk: DLP- SDES- TLP- FCP- CmpltTO- CmpltAbrt- UnxCmplt- RxOF- MalfTLP- ECRC- UnsupReq- ACSViol- UESvrt: DLP+ SDES+ TLP- FCP+ CmpltTO- CmpltAbrt- UnxCmplt- RxOF+ MalfTLP+ ECRC- UnsupReq- ACSViol- CESta: RxErr- BadTLP- BadDLLP- Rollover- Timeout- NonFatalErr+ CEMsk: RxErr- BadTLP- BadDLLP- Rollover- Timeout- NonFatalErr+ AERCap: First Error Pointer: 1f, GenCap+ CGenEn- ChkCap+ ChkEn- Capabilities: [148] Virtual Channel Capabilities: [520] Access Control Services ACSCap: SrcValid+ TransBlk+ ReqRedir+ CmpltRedir+ UpstreamFwd+ EgressCtrl+ DirectTrans+ ACSCtl: SrcValid- TransBlk- ReqRedir- CmpltRedir- UpstreamFwd- EgressCtrl- DirectTrans- Capabilities: [950] Vendor Specific Information Kernel driver in use: pcieport 15:00.0 PCI bridge: Integrated Device Technology, Inc. Device 8091 (rev 02) (prog-if 00 [Normal decode]) Control: I/O+ Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- DisINTx- Status: Cap+ 66MHz- UDF- FastB2B- ParErr- DEVSEL=fast >TAbort- SERR- TAbort- Reset- FastB2B- PriDiscTmr- SecDiscTmr- DiscTmrStat- DiscTmrSERREn- Capabilities: [40] Express (v2) Upstream Port, MSI 00 DevCap: MaxPayload 2048 bytes, PhantFunc 0, Latency L0s <64ns, L1 <1us ExtTag+ AttnBtn- AttnInd- PwrInd- RBE+ FLReset-SlotPowerLimit 0.000000W DevCtl: Report errors: Correctable- Non-Fatal- Fatal- Unsupported- RlxdOrd- ExtTag- PhantFunc- AuxPwr- NoSnoop- MaxPayload 256 bytes, MaxReadReq 128 bytes DevSta: CorrErr+ UncorrErr- FatalErr- UnsuppReq+ AuxPwr- TransPend- LnkCap: Port #0, Speed 5GT/s, Width x8, ASPM L0s L1, Latency L0 <4us, L1 <4us ClockPM- Surprise- LLActRep- BwNot- LnkCtl: ASPM Disabled; Disabled- Retrain- CommClk- ExtSynch- ClockPM- AutWidDis- BWInt- AutBWInt- LnkSta: Speed 5GT/s, Width x1, TrErr- Train- SlotClk- DLActive- BWMgmt- ABWMgmt- DevCap2: Completion Timeout: Not Supported, TimeoutDis- DevCtl2: Completion Timeout: 50us to 50ms, TimeoutDis- LnkCtl2: Target Link Speed: 5GT/s, EnterCompliance- SpeedDis-, Selectable De-emphasis: -6dB Transmit Margin: Normal Operating Range, EnterModifiedCompliance- ComplianceSOS- Compliance De-emphasis: -6dB LnkSta2: Current De-emphasis Level: -6dB Capabilities: [c0] Power Management version 3 Flags: PMEClk- DSI- D1- D2- AuxCurrent=0mA PME(D0+,D1-,D2-,D3hot+,D3cold+) Status: D0 NoSoftRst+ PME-Enable- DSel=0 DScale=0 PME- Capabilities: [f0] Subsystem: Dolphin Interconnect Solutions AS Device 0611 Capabilities: [100] Advanced Error Reporting UESta: DLP- SDES- TLP- FCP- CmpltTO- CmpltAbrt- UnxCmplt- RxOF- MalfTLP- ECRC- UnsupReq- ACSViol- UEMsk: DLP- SDES- TLP- FCP- CmpltTO- CmpltAbrt- UnxCmplt- RxOF- MalfTLP- ECRC- UnsupReq- ACSViol- UESvrt: DLP+ SDES+ TLP- FCP+ CmpltTO- CmpltAbrt- UnxCmplt- RxOF+ MalfTLP+ ECRC- UnsupReq- ACSViol- CESta: RxErr- BadTLP- BadDLLP- Rollover- Timeout- NonFatalErr+ CEMsk: RxErr- BadTLP- BadDLLP- Rollover- Timeout- NonFatalErr+ AERCap: First Error Pointer: 00, GenCap+ CGenEn- ChkCap+ ChkEn- Capabilities: [180] Device Serial Number 00-00-43-45-00-00-09-2c Capabilities: [200] Virtual Channel Capabilities: [330] #12 Kernel driver in use: pcieport 15:00.1 Bridge: Integrated Device Technology, Inc. Device 8091 (rev 02) Subsystem: Dolphin Interconnect Solutions AS Device 1611 Control: I/O+ Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- DisINTx+ Status: Cap+ 66MHz- UDF- FastB2B- ParErr- DEVSEL=fast >TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- Reset- FastB2B- PriDiscTmr- SecDiscTmr- DiscTmrStat- DiscTmrSERREn- Capabilities: [50] MSI: Enable- Count=1/1 Maskable- 64bit+ Address: 0000000000000000 Data: 0000 Capabilities: [78] Power Management version 3 Flags: PMEClk- DSI- D1+ D2+ AuxCurrent=375mA PME(D0+,D1+,D2+,D3hot+,D3cold+) Status: D0 NoSoftRst+ PME-Enable- DSel=0 DScale=0 PME- Capabilities: [80] Express (v1) PCI/PCI-X Bridge, MSI 00 DevCap: MaxPayload 128 bytes, PhantFunc 0, Latency L0s <64ns, L1 <1us ExtTag+ AttnBtn- AttnInd- PwrInd- RBE- FLReset- DevCtl: Report errors: Correctable- Non-Fatal- Fatal- Unsupported- RlxdOrd- ExtTag- PhantFunc- AuxPwr- NoSnoop+ BrConfRtry- MaxPayload 128 bytes, MaxReadReq 512 bytes DevSta: CorrErr+ UncorrErr- FatalErr- UnsuppReq+ AuxPwr+ TransPend- LnkCap: Port #0, Speed 2.5GT/s, Width x1, ASPM L0s L1, Latency L0 <2us, L1 <16us ClockPM- Surprise- LLActRep- BwNot- LnkCtl: ASPM Disabled; Disabled- Retrain- CommClk+ ExtSynch- ClockPM- AutWidDis- BWInt- AutBWInt- LnkSta: Speed 2.5GT/s, Width x1, TrErr- Train- SlotClk+ DLActive- BWMgmt- ABWMgmt- Capabilities: [a4] Subsystem: Super Micro Computer Inc Device 0833 Capabilities: [100] Virtual Channel Capabilities: [800] Advanced Error Reporting UESta: DLP- SDES- TLP- FCP- CmpltTO- CmpltAbrt- UnxCmplt- RxOF- MalfTLP- ECRC- UnsupReq- ACSViol- UEMsk: DLP- SDES- TLP- FCP- CmpltTO- CmpltAbrt- UnxCmplt- RxOF- MalfTLP- ECRC- UnsupReq- ACSViol- UESvrt: DLP+ SDES+ TLP- FCP+ CmpltTO- CmpltAbrt- UnxCmplt- RxOF+ MalfTLP+ ECRC- UnsupReq- ACSViol- CESta: RxErr+ BadTLP- BadDLLP- Rollover- Timeout- NonFatalErr+ CEMsk: RxErr- BadTLP- BadDLLP- Rollover- Timeout- NonFatalErr+ AERCap: First Error Pointer: 00, GenCap- CGenEn- ChkCap- ChkEn- 19:00.0 VGA compatible controller: ASPEED Technology, Inc. ASPEED Graphics Family (rev 30) (prog-if 00 [VGA controller]) Subsystem: Super Micro Computer Inc Device 0833 Control: I/O+ Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- DisINTx- Status: Cap+ 66MHz- UDF- FastB2B- ParErr- DEVSEL=medium >TAbort- SERR- [disabled] Capabilities: [40] Power Management version 3 Flags: PMEClk- DSI- D1+ D2+ AuxCurrent=375mA PME(D0+,D1+,D2+,D3hot+,D3cold+) Status: D0 NoSoftRst- PME-Enable- DSel=0 DScale=0 PME- Capabilities: [50] MSI: Enable- Count=1/4 Maskable- 64bit+ Address: 0000000000000000 Data: 0000 1a:00.0 Ethernet controller: Intel Corporation Device 1521 (rev 01) Subsystem: Super Micro Computer Inc Device 1521 Control: I/O+ Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- DisINTx+ Status: Cap+ 66MHz- UDF- FastB2B- ParErr- DEVSEL=fast >TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- SERR- TAbort- SERR- (32-bit, prefetchable) [disabled] ff:1e.4 System peripheral: Intel Corporation Device 6f9c (rev 01) Subsystem: Super Micro Computer Inc Device 0833 Control: I/O- Mem- BusMaster- SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- DisINTx- Status: Cap- 66MHz- UDF- FastB2B- ParErr- DEVSEL=fast >TAbort- SERR- TAbort- SERR- TAbort- SERR-