corey.gray@zotws7:/opt/rtcds/userapps/release/sys/h1/scripts$ ./PEM_weekly_magnetic_injection.py Performing PEM injections through these channels: H1:PEM-CS_GDS_0_EXC H1:PEM-CS_GDS_0_EXC H1:PEM-EX_GDS_1_EXC H1:PEM-EX_GDS_1_EXC H1:PEM-EY_GDS_1_EXC H1:PEM-EY_GDS_1_EXC Use Control+C anytime to STOP ALL injections. Performing injection with gain 500000 from 10 to 100 Hz. Injecting through channel H1:PEM-CS_GDS_0_EXC for 90 seconds. *** Break *** segmentation violation =========================================================== There was a crash. This is the entire stack trace of all threads: =========================================================== Thread 4 (Thread 0x7f7e4b4c7700 (LWP 3472)): #0 0x00007f7e6c65c17f in pthread_cond_wait GLIBC_2.3.2 () from /lib/x86_64-linux-gnu/libpthread.so.0 #1 0x00007f7e65c8381d in syncWithHeartbeat () from /usr/lib/libtestpoint.so #2 0x00007f7e65c81834 in ?? () from /usr/lib/libtestpoint.so #3 0x00007f7e6c6564a4 in start_thread () from /lib/x86_64-linux-gnu/libpthread.so.0 #4 0x00007f7e6ba73d0f in clone () from /lib/x86_64-linux-gnu/libc.so.6 Thread 3 (Thread 0x7f7e4b5c8700 (LWP 3471)): #0 0x00007f7e6c65fc97 in do_sigwait () from /lib/x86_64-linux-gnu/libpthread.so.0 #1 0x00007f7e6c65fd0d in sigwait () from /lib/x86_64-linux-gnu/libpthread.so.0 #2 0x00007f7e65c83778 in installSignal () from /usr/lib/libtestpoint.so #3 0x00007f7e6c6564a4 in start_thread () from /lib/x86_64-linux-gnu/libpthread.so.0 #4 0x00007f7e6ba73d0f in clone () from /lib/x86_64-linux-gnu/libc.so.6 Thread 2 (Thread 0x7f7e5753f700 (LWP 3469)): #0 0x00007f7e6ba6c603 in select () from /lib/x86_64-linux-gnu/libc.so.6 #1 0x0000555d958edb89 in ?? () #2 0x0000555d9581a84a in PyEval_EvalFrameEx () #3 0x0000555d958189f5 in PyEval_EvalCodeEx () #4 0x0000555d95835778 in ?? () #5 0x0000555d958070c3 in PyObject_Call () #6 0x0000555d958213a0 in PyEval_EvalFrameEx () #7 0x0000555d9582014f in PyEval_EvalFrameEx () #8 0x0000555d9582014f in PyEval_EvalFrameEx () #9 0x0000555d958189f5 in PyEval_EvalCodeEx () #10 0x0000555d958355be in ?? () #11 0x0000555d958070c3 in PyObject_Call () #12 0x0000555d9584be1e in ?? () #13 0x0000555d958070c3 in PyObject_Call () #14 0x0000555d95824a10 in PyEval_CallObjectWithKeywords () #15 0x0000555d958ed722 in ?? () #16 0x00007f7e6c6564a4 in start_thread () from /lib/x86_64-linux-gnu/libpthread.so.0 #17 0x00007f7e6ba73d0f in clone () from /lib/x86_64-linux-gnu/libc.so.6 Thread 1 (Thread 0x7f7e6ca5c5c0 (LWP 3458)): #0 0x00007f7e6ba4304a in waitpid () from /lib/x86_64-linux-gnu/libc.so.6 #1 0x00007f7e6b9ca0ab in ?? () from /lib/x86_64-linux-gnu/libc.so.6 #2 0x00007f7e5a819519 in TUnixSystem::StackTrace() () from /usr/lib/x86_64-linux-gnu/libCore.so.5.34 #3 0x00007f7e5a81b63c in TUnixSystem::DispatchSignals(ESignals) () from /usr/lib/x86_64-linux-gnu/libCore.so.5.34 #4 #5 0x00007f7e676feb19 in awg_client () from /usr/lib/libawg.so #6 0x00007f7e676fee11 in awgSetChannel () from /usr/lib/libawg.so #7 0x00007f7e69227038 in ffi_call_unix64 () from /usr/lib/x86_64-linux-gnu/libffi.so.6 #8 0x00007f7e69226a9a in ffi_call () from /usr/lib/x86_64-linux-gnu/libffi.so.6 #9 0x00007f7e6943b224 in _ctypes_callproc () from /usr/lib/python2.7/lib-dynload/_ctypes.x86_64-linux-gnu.so #10 0x00007f7e6943abe5 in ?? () from /usr/lib/python2.7/lib-dynload/_ctypes.x86_64-linux-gnu.so #11 0x0000555d958070c3 in PyObject_Call () #12 0x0000555d9582035f in PyEval_EvalFrameEx () #13 0x0000555d9582014f in PyEval_EvalFrameEx () #14 0x0000555d9582014f in PyEval_EvalFrameEx () #15 0x0000555d958189f5 in PyEval_EvalCodeEx () #16 0x0000555d95820448 in PyEval_EvalFrameEx () #17 0x0000555d958189f5 in PyEval_EvalCodeEx () #18 0x0000555d95820448 in PyEval_EvalFrameEx () #19 0x0000555d958189f5 in PyEval_EvalCodeEx () #20 0x0000555d958187b9 in PyEval_EvalCode () #21 0x0000555d95848bff in ?? () #22 0x0000555d95843b52 in PyRun_FileExFlags () #23 0x0000555d9584369e in PyRun_SimpleFileExFlags () #24 0x0000555d957f4771 in Py_Main () #25 0x00007f7e6b9ab2e1 in __libc_start_main () from /lib/x86_64-linux-gnu/libc.so.6 #26 0x0000555d957f3f9a in _start () =========================================================== The lines below might hint at the cause of the crash. If they do not help you then please submit a bug report at http://root.cern.ch/bugs. Please post the ENTIRE stack trace from above as an attachment in addition to anything else that might help us fixing this issue. =========================================================== #5 0x00007f7e676feb19 in awg_client () from /usr/lib/libawg.so #6 0x00007f7e676fee11 in awgSetChannel () from /usr/lib/libawg.so #7 0x00007f7e69227038 in ffi_call_unix64 () from /usr/lib/x86_64-linux-gnu/libffi.so.6 #8 0x00007f7e69226a9a in ffi_call () from /usr/lib/x86_64-linux-gnu/libffi.so.6 #9 0x00007f7e6943b224 in _ctypes_callproc () from /usr/lib/python2.7/lib-dynload/_ctypes.x86_64-linux-gnu.so #10 0x00007f7e6943abe5 in ?? () from /usr/lib/python2.7/lib-dynload/_ctypes.x86_64-linux-gnu.so #11 0x0000555d958070c3 in PyObject_Call () #12 0x0000555d9582035f in PyEval_EvalFrameEx () #13 0x0000555d9582014f in PyEval_EvalFrameEx () #14 0x0000555d9582014f in PyEval_EvalFrameEx () #15 0x0000555d958189f5 in PyEval_EvalCodeEx () #16 0x0000555d95820448 in PyEval_EvalFrameEx () #17 0x0000555d958189f5 in PyEval_EvalCodeEx () #18 0x0000555d95820448 in PyEval_EvalFrameEx () #19 0x0000555d958189f5 in PyEval_EvalCodeEx () #20 0x0000555d958187b9 in PyEval_EvalCode () #21 0x0000555d95848bff in ?? () #22 0x0000555d95843b52 in PyRun_FileExFlags () #23 0x0000555d9584369e in PyRun_SimpleFileExFlags () #24 0x0000555d957f4771 in Py_Main () #25 0x00007f7e6b9ab2e1 in __libc_start_main () from /lib/x86_64-linux-gnu/libc.so.6 #26 0x0000555d957f3f9a in _start () =========================================================== Segmentation fault corey.gray@zotws7:/opt/rtcds/userapps/release/sys/h1/scripts$