ASC Yaw Sensing Matrix, [ct/rad] (26th Feb 2020)

dof: DHARD CHARD DSOFT CSOFT
AS_A_DC_YAW 1.5e+12 -153 1.2e+11 -25 2.5e+10 -100 2.2e+10 108
AS_A_RF36_I_YAW 3.4e+13 -177 5.3e+12 -84 6.65e+12 -18 3.1e+12 130
AS_A_RF36_Q_YAW 8.9e+13 -28 2.9e+12 -49 1.08e+13 -15 1.0e+12 -39
AS_A_RF45_I_YAW 2.04e+13 -6 7.17e+11 164 6.08e+11 5 7.7e+10 16
AS_A_RF45_Q_YAW 5.14e+13 -22 1.6e+12 173 8.19e+11 47 1.9e+11 105
AS_B_DC_YAW 9.3e+11 37 9.2e+10 -97 2.1e+10 -43 2.7e+10 -50
AS_B_RF36_I_YAW 6.8e+13 -170 6.6e+12 -52 1.20e+13 161 3.9e+12 106
AS_B_RF36_Q_YAW 4.1e+13 -111 7.9e+12 170 1.07e+13 169 9.3e+11 -50
AS_B_RF45_I_YAW 4.7e+12 -47 4.3e+11 -164 3.28e+11 -12 2.7e+11 68
AS_B_RF45_Q_YAW 4.33e+13 160 1.62e+12 -4 6.03e+11 -91 2.5e+11 -106
AS_C_YAW 2.71e+06 -163 1.0e+05 -38 6.3e+04 129 4.3e+04 -126
REFL_A_DC_YAW 2.2e+12 -56 4.0e+10 -37 6.7e+10 109 3.9e+10 -7
REFL_A_RF9_I_YAW 1.0e+14 130 1.5e+13 82 1.2e+13 80 4.6e+12 63
REFL_A_RF9_Q_YAW 6.5e+13 -168 1.9e+13 18 2.2e+12 23 1.7e+12 67
REFL_A_RF45_I_YAW 4.4e+14 149 1.0e+14 36 3.9e+13 65 1.3e+13 49
REFL_A_RF45_Q_YAW 1.8e+14 132 3.8e+13 38 1.2e+13 56 4.2e+12 52
REFL_B_DC_YAW 8.7e+11 -94 1.7e+11 20 1.4e+10 106 4.3e+10 -36
REFL_B_RF9_I_YAW 7.7e+13 8 2.10e+13 153 2.4e+12 102 5.3e+12 -4
REFL_B_RF9_Q_YAW 2.9e+13 123 6.4e+12 -94 2.4e+12 -123 2.6e+12 -167
REFL_B_RF45_I_YAW 1.9e+14 43 7.0e+13 -169 1.4e+13 -127 6.4e+12 -168
REFL_B_RF45_Q_YAW 1.4e+13 -110 1.4e+13 -148 5.7e+12 -117 2.6e+12 -93
POP_X_RF_I_YAW 1.1e+14 -172 1.6e+13 -58 6.3e+12 -105 2.9e+12 178
POP_X_RF_Q_YAW 3.9e+13 161 5.3e+12 -169 2.0e+12 -75 4.0e+12 118
POP_A_YAW 6.2e+09 -48 3.91e+09 -21 3.5e+08 45 2.0e+08 -50
POP_B_YAW 3.3e+10 -50 3.19e+09 159 4.9e+08 -124 5.5e+08 147
X_TR_A_YAW 2.9e+11 165 1.93e+11 159 8.6e+09 -121 2.5e+09 -31
X_TR_B_YAW 2.0e+11 166 1.49e+11 160 3.87e+10 -26 3.80e+10 -32
Y_TR_A_YAW 3.9e+11 159 3.30e+11 -21 2.02e+10 155 1.5e+10 -10
Y_TR_B_YAW 2.4e+11 152 1.10e+11 -25 4.18e+10 -22 3.68e+10 150