ASC Yaw Sensing Matrix, [W/rad] (26th Feb 2020)
| dof: |
DHARD
|
CHARD
|
DSOFT
|
CSOFT
|
|
AS_A_DC_YAW
|
2.2e+05
-153
|
1.8e+04
-25
|
3.7e+03
-100
|
3.2e+03
108
|
|
AS_A_RF36_I_YAW
|
7.9e+05
-177
|
1.2e+05
-84
|
1.54e+05
-18
|
7.2e+04
130
|
|
AS_A_RF36_Q_YAW
|
2.0e+06
-28
|
6.8e+04
-49
|
2.50e+05
-15
|
2.4e+04
-39
|
|
AS_A_RF45_I_YAW
|
1.79e+06
-6
|
6.27e+04
164
|
5.32e+04
5
|
6.8e+03
16
|
|
AS_A_RF45_Q_YAW
|
4.49e+06
-22
|
1.4e+05
173
|
7.16e+04
47
|
1.7e+04
105
|
|
AS_B_DC_YAW
|
1.3e+05
37
|
1.3e+04
-97
|
3.0e+03
-43
|
3.9e+03
-50
|
|
AS_B_RF36_I_YAW
|
1.1e+06
-170
|
1.1e+05
-52
|
1.97e+05
161
|
6.4e+04
106
|
|
AS_B_RF36_Q_YAW
|
6.7e+05
-111
|
1.3e+05
170
|
1.76e+05
169
|
1.5e+04
-50
|
|
AS_B_RF45_I_YAW
|
4.1e+05
-47
|
3.7e+04
-164
|
2.86e+04
-12
|
2.4e+04
68
|
|
AS_B_RF45_Q_YAW
|
3.79e+06
160
|
1.41e+05
-4
|
5.27e+04
-91
|
2.2e+04
-106
|
|
AS_C_YAW
|
4.41e-02
-163
|
1.7e-03
-38
|
1.0e-03
129
|
7.1e-04
-126
|
|
REFL_A_DC_YAW
|
3.2e+05
-56
|
5.8e+03
-37
|
9.7e+03
109
|
5.7e+03
-7
|
|
REFL_A_RF9_I_YAW
|
1.2e+06
130
|
1.7e+05
82
|
1.4e+05
80
|
5.3e+04
63
|
|
REFL_A_RF9_Q_YAW
|
7.5e+05
-168
|
2.2e+05
18
|
2.5e+04
23
|
1.9e+04
67
|
|
REFL_A_RF45_I_YAW
|
9.7e+06
149
|
2.3e+06
36
|
8.6e+05
65
|
2.7e+05
49
|
|
REFL_A_RF45_Q_YAW
|
4.0e+06
132
|
8.3e+05
38
|
2.6e+05
56
|
9.3e+04
52
|
|
REFL_B_DC_YAW
|
1.3e+05
-94
|
2.4e+04
20
|
2.1e+03
106
|
6.2e+03
-36
|
|
REFL_B_RF9_I_YAW
|
8.9e+05
8
|
2.43e+05
153
|
2.8e+04
102
|
6.1e+04
-4
|
|
REFL_B_RF9_Q_YAW
|
3.3e+05
123
|
7.4e+04
-94
|
2.8e+04
-123
|
2.9e+04
-167
|
|
REFL_B_RF45_I_YAW
|
4.1e+06
43
|
1.5e+06
-169
|
3.1e+05
-127
|
1.4e+05
-168
|
|
REFL_B_RF45_Q_YAW
|
3.1e+05
-110
|
3.1e+05
-148
|
1.3e+05
-117
|
5.8e+04
-93
|
|
POP_X_RF_I_YAW
|
8.9e+05
-172
|
1.3e+05
-58
|
5.2e+04
-105
|
2.4e+04
178
|
|
POP_X_RF_Q_YAW
|
3.2e+05
161
|
4.4e+04
-169
|
1.7e+04
-75
|
3.3e+04
118
|
|
POP_A_YAW
|
1.0e+03
-48
|
6.38e+02
-21
|
5.7e+01
45
|
3.3e+01
-50
|
|
POP_B_YAW
|
5.4e+03
-50
|
5.20e+02
159
|
7.9e+01
-124
|
9.0e+01
147
|
|
X_TR_A_YAW
|
3.3e+04
165
|
2.23e+04
159
|
9.9e+02
-121
|
2.8e+02
-31
|
|
X_TR_B_YAW
|
2.3e+04
166
|
1.72e+04
160
|
4.47e+03
-26
|
4.39e+03
-32
|
|
Y_TR_A_YAW
|
4.5e+04
159
|
3.81e+04
-21
|
2.33e+03
155
|
1.7e+03
-10
|
|
Y_TR_B_YAW
|
2.7e+04
152
|
1.27e+04
-25
|
4.82e+03
-22
|
4.24e+03
150
|