mode 1 - current butter("BandPass",6,510.712,510.718)gain(120,"dB") mode 6 - current butter("BandPass",6,510.7258,510.7298)gain(120,"dB") mode 1 - NEW butter("BandPass",8,510.712,510.717)gain(120,"dB") mode 6 - NEW butter("BandPass",8,510.7243,510.7293)gain(120,"dB") ------------------------------------------ mode 11 - current butter("BandPass",4,1000.011,1000.111)gain(120,"dB") mode 12 - current butter("BandPass",4,1000.373,1000.473)gain(120,"dB") mode 18 butter("BandPass",6,1000.293,1000.299)gain(120,"dB") mode 20 butter("BandPass",6,1000.304,1000.310)gain(120,"dB") mode 11 - new filter butter("BandPass",6,1000.041,1000.081)gain(120,"dB") mode 12 - new filter butter("BandPass",8,1000.408,1000.448)gain(120,"dB") ------------------------------------------ peak frequencies, updated 10mar2020 ETMY: mode1: 510.715 mode 6: 510.7264 mode 7: 513.41 mode 8: 513.514 peak frequencies, updated 15mar2020 mode 11: 1000.0645 mode 12: 1000.426 mode 18: 1000.297 (change from 1000.296) mode 20: 1000.3085 (change from 1000.307)