# Frequency [Hz], LHO DARM noise median averaged asd bias corrected [m/rtHz] 0.000000000000000000e+00 inf 2.000000000000000000e+00 3.341545272915043336e-12 4.000000000000000000e+00 4.463139758363931105e-14 6.000000000000000000e+00 6.522737506193006593e-15 8.000000000000000000e+00 8.244815773952135849e-16 1.000000000000000000e+01 1.585489806348087151e-16 1.200000000000000000e+01 5.306470882854525565e-17 1.400000000000000000e+01 1.746596010425084898e-16 1.600000000000000000e+01 2.048548533886863517e-16 1.800000000000000000e+01 1.760418761433831357e-16 2.000000000000000000e+01 5.308258777432725544e-17 2.200000000000000000e+01 5.197428049952559142e-18 2.400000000000000000e+01 1.678437360084476381e-18 2.600000000000000000e+01 5.308898874380949196e-19 2.800000000000000000e+01 3.271101293885012911e-19 3.000000000000000000e+01 2.318596460313752356e-19 3.200000000000000000e+01 1.819862758314697724e-19 3.400000000000000000e+01 1.442132785417397025e-19 3.600000000000000000e+01 1.283981016078749590e-19 3.800000000000000000e+01 1.036478303294742184e-19 4.000000000000000000e+01 9.644297167942512729e-20 4.200000000000000000e+01 8.851543735552413807e-20 4.400000000000000000e+01 7.887321740038765262e-20 4.600000000000000000e+01 7.038048873287131547e-20 4.800000000000000000e+01 6.598632647776032204e-20 5.000000000000000000e+01 6.380591641429269433e-20 5.200000000000000000e+01 6.132610683505860206e-20 5.400000000000000000e+01 5.883253105077789197e-20 5.600000000000000000e+01 5.598617529071526541e-20 5.800000000000000000e+01 4.855386374223012543e-19 6.000000000000000000e+01 9.566947461912862798e-19 6.200000000000000000e+01 4.771300469761969200e-19 6.400000000000000000e+01 4.797774185928053439e-20 6.600000000000000000e+01 4.598001677813385129e-20 6.800000000000000000e+01 4.544846502268606403e-20 7.000000000000000000e+01 4.448641839846523551e-20 7.200000000000000000e+01 4.391105583870965889e-20 7.400000000000000000e+01 4.622619646346523168e-20 7.600000000000000000e+01 4.583495231268919099e-20 7.800000000000000000e+01 4.240723497901383287e-20 8.000000000000000000e+01 4.283052141491478284e-20 8.200000000000000000e+01 4.376743488211520977e-20 8.400000000000000000e+01 4.188339554893935711e-20 8.600000000000000000e+01 4.064172543240408701e-20 8.800000000000000000e+01 4.134786259631601450e-20 9.000000000000000000e+01 4.171103451544529570e-20 9.200000000000000000e+01 4.004035121240307369e-20 9.400000000000000000e+01 3.899300043012469281e-20 9.600000000000000000e+01 3.855370244073799468e-20 9.800000000000000000e+01 3.834332484450471095e-20 1.000000000000000000e+02 3.844290957125080267e-20 1.020000000000000000e+02 3.790924019502381579e-20 1.040000000000000000e+02 3.786355547229431194e-20 1.060000000000000000e+02 3.837496037309715891e-20 1.080000000000000000e+02 3.799876146649807581e-20 1.100000000000000000e+02 3.761961427915600259e-20 1.120000000000000000e+02 3.757907663885112972e-20 1.140000000000000000e+02 3.769507648570041450e-20 1.160000000000000000e+02 3.773088803303360089e-20 1.180000000000000000e+02 4.149283371100469804e-20 1.200000000000000000e+02 5.180743375455823958e-20 1.220000000000000000e+02 4.106068497877208237e-20 1.240000000000000000e+02 3.716479320651014418e-20 1.260000000000000000e+02 3.709534012587712819e-20 1.280000000000000000e+02 3.675050050700424859e-20 1.300000000000000000e+02 3.652762409224059116e-20 1.320000000000000000e+02 3.669595439731917091e-20 1.340000000000000000e+02 3.657129473850642024e-20 1.360000000000000000e+02 3.667659145282098065e-20 1.380000000000000000e+02 3.658596427526106679e-20 1.400000000000000000e+02 3.673449965884929781e-20 1.420000000000000000e+02 3.705216256413274946e-20 1.440000000000000000e+02 3.701687127206440019e-20 1.460000000000000000e+02 3.718154325118100189e-20 1.480000000000000000e+02 3.763110196708006496e-20 1.500000000000000000e+02 3.841260044837681303e-20 1.520000000000000000e+02 3.818426673037237299e-20 1.540000000000000000e+02 3.795928422061923492e-20 1.560000000000000000e+02 3.788236041108386527e-20 1.580000000000000000e+02 3.804925905829498920e-20 1.600000000000000000e+02 3.821733387199988970e-20 1.620000000000000000e+02 3.836042777499666139e-20 1.640000000000000000e+02 3.840485039478134624e-20 1.660000000000000000e+02 3.835687984571990614e-20 1.680000000000000000e+02 3.856649237287904997e-20 1.700000000000000000e+02 3.856636048171028440e-20 1.720000000000000000e+02 3.854102550537965259e-20 1.740000000000000000e+02 3.862531768307968495e-20 1.760000000000000000e+02 3.859644742359072251e-20 1.780000000000000000e+02 9.928628000802596913e-20 1.800000000000000000e+02 1.945241758219481788e-19 1.820000000000000000e+02 1.039165819710441965e-19 1.840000000000000000e+02 3.897235442639840309e-20 1.860000000000000000e+02 3.888594637818845777e-20 1.880000000000000000e+02 3.899925462367947345e-20 1.900000000000000000e+02 3.914529544222568398e-20 1.920000000000000000e+02 3.914515988901123216e-20 1.940000000000000000e+02 3.949425866693633810e-20 1.960000000000000000e+02 3.963222880296338818e-20 1.980000000000000000e+02 3.986289426287580225e-20 2.000000000000000000e+02 4.000118838618322081e-20 2.020000000000000000e+02 4.009199201970590989e-20 2.040000000000000000e+02 4.032286369818824666e-20 2.060000000000000000e+02 4.050430108717706563e-20 2.080000000000000000e+02 4.067660402419623719e-20 2.100000000000000000e+02 4.096490127308723043e-20 2.120000000000000000e+02 4.112240072928368239e-20 2.140000000000000000e+02 4.129728757296576760e-20 2.160000000000000000e+02 4.154129496818565742e-20 2.180000000000000000e+02 4.186575635588497164e-20 2.200000000000000000e+02 4.213881212353261752e-20 2.220000000000000000e+02 4.258423995677663268e-20 2.240000000000000000e+02 4.259052661975017433e-20 2.260000000000000000e+02 4.273039964732784240e-20 2.280000000000000000e+02 4.290857149573390767e-20 2.300000000000000000e+02 4.310697640052868883e-20 2.320000000000000000e+02 4.353260508822493712e-20 2.340000000000000000e+02 4.366381741306281820e-20 2.360000000000000000e+02 4.378718115008492466e-20 2.380000000000000000e+02 4.405049496299575852e-20 2.400000000000000000e+02 4.442904039030385075e-20 2.420000000000000000e+02 4.442875978275752252e-20 2.440000000000000000e+02 4.458921462354954515e-20 2.460000000000000000e+02 4.488792170462898936e-20 2.480000000000000000e+02 4.505984878906811879e-20 2.500000000000000000e+02 4.540465525474642549e-20 2.520000000000000000e+02 4.565951015997626632e-20 2.540000000000000000e+02 4.595567112898560362e-20 2.560000000000000000e+02 4.592356067394087971e-20 2.580000000000000000e+02 4.617928013631312514e-20 2.600000000000000000e+02 4.632273485386527549e-20 2.620000000000000000e+02 4.663860821365893676e-20 2.640000000000000000e+02 4.676427182099187488e-20 2.660000000000000000e+02 4.700391680063966123e-20 2.680000000000000000e+02 4.724787717865674898e-20 2.700000000000000000e+02 4.755011497101215958e-20 2.720000000000000000e+02 4.800797256770313832e-20 2.740000000000000000e+02 4.788832834334499474e-20 2.760000000000000000e+02 4.811034323316216038e-20 2.780000000000000000e+02 4.855802659036840566e-20 2.800000000000000000e+02 4.893126855270450321e-20 2.820000000000000000e+02 4.878938717957280728e-20 2.840000000000000000e+02 4.894646896574617779e-20 2.860000000000000000e+02 4.910941777213984007e-20 2.880000000000000000e+02 4.926802930025435537e-20 2.900000000000000000e+02 4.914897011257429710e-20 2.920000000000000000e+02 4.928610679073070867e-20 2.940000000000000000e+02 4.954663783667037912e-20 2.960000000000000000e+02 4.970766004423751595e-20 2.980000000000000000e+02 7.883167874035799259e-20 3.000000000000000000e+02 1.136406176103125810e-19 3.020000000000000000e+02 9.809891520730970787e-20 3.040000000000000000e+02 9.010365219763415920e-20 3.060000000000000000e+02 5.410939019931766089e-20 3.080000000000000000e+02 5.033189355130690415e-20 3.100000000000000000e+02 5.053173879411039348e-20 3.120000000000000000e+02 5.085603828552524604e-20 3.140000000000000000e+02 5.089791489858124053e-20 3.160000000000000000e+02 5.104440982354053452e-20 3.180000000000000000e+02 5.131373693911562356e-20 3.200000000000000000e+02 5.134617205558575866e-20 3.220000000000000000e+02 5.149447511782908026e-20 3.240000000000000000e+02 5.175064774068382389e-20 3.260000000000000000e+02 5.206022192195987376e-20 3.280000000000000000e+02 5.223269938949453225e-20 3.300000000000000000e+02 5.215514054834012003e-20 3.320000000000000000e+02 5.243438931860738574e-20 3.340000000000000000e+02 5.261210245859934787e-20 3.360000000000000000e+02 5.283336369019457360e-20 3.380000000000000000e+02 5.284836047848729443e-20 3.400000000000000000e+02 5.292115308016715292e-20 3.420000000000000000e+02 5.322039963801822242e-20 3.440000000000000000e+02 5.321950600197260289e-20 3.460000000000000000e+02 5.333663303708052742e-20 3.480000000000000000e+02 5.359712860293042129e-20 3.500000000000000000e+02 5.372725956861309497e-20 3.520000000000000000e+02 5.375125995351023199e-20 3.540000000000000000e+02 5.394024397672054621e-20 3.560000000000000000e+02 5.405652790483710299e-20 3.580000000000000000e+02 5.407036393853756074e-20 3.600000000000000000e+02 5.414330033962658464e-20 3.620000000000000000e+02 5.433869032779230583e-20 3.640000000000000000e+02 5.449633949277035962e-20 3.660000000000000000e+02 5.460745172782887736e-20 3.680000000000000000e+02 5.463805805237379534e-20 3.700000000000000000e+02 5.464868814236716196e-20 3.720000000000000000e+02 5.485164884506569708e-20 3.740000000000000000e+02 5.501218441559823396e-20 3.760000000000000000e+02 5.515622678216076702e-20 3.780000000000000000e+02 5.508046693093328900e-20 3.800000000000000000e+02 5.529325935953821907e-20 3.820000000000000000e+02 5.519437686388893239e-20 3.840000000000000000e+02 5.517289565889972581e-20 3.860000000000000000e+02 5.535401760341944119e-20 3.880000000000000000e+02 5.546358351272567121e-20 3.900000000000000000e+02 5.548265394517488194e-20 3.920000000000000000e+02 5.555455613954274193e-20 3.940000000000000000e+02 5.536082823988012619e-20 3.960000000000000000e+02 5.550933280179865877e-20 3.980000000000000000e+02 5.556343237956599009e-20 4.000000000000000000e+02 5.554827662733737410e-20 4.020000000000000000e+02 5.549348451099831911e-20 4.040000000000000000e+02 5.559077907164145389e-20 4.060000000000000000e+02 5.883179612544969111e-20 4.080000000000000000e+02 4.715073654628113973e-19 4.100000000000000000e+02 1.198029613941125641e-18 4.120000000000000000e+02 8.335077231766536529e-19 4.140000000000000000e+02 6.993679811159728776e-20 4.160000000000000000e+02 5.732131015550295403e-20 4.180000000000000000e+02 5.679825764792152607e-20 4.200000000000000000e+02 5.756711588171976846e-20 4.220000000000000000e+02 5.645559325968912108e-20 4.240000000000000000e+02 5.619788294568590218e-20 4.260000000000000000e+02 5.614048750094506417e-20 4.280000000000000000e+02 5.606487358084721562e-20 4.300000000000000000e+02 5.585795684763741005e-20 4.320000000000000000e+02 5.606138357202381536e-20 4.340000000000000000e+02 5.599582040481955975e-20 4.360000000000000000e+02 5.583074955422945217e-20 4.380000000000000000e+02 5.548548010646228825e-20 4.400000000000000000e+02 5.536560695812161877e-20 4.420000000000000000e+02 5.515486694106979704e-20 4.440000000000000000e+02 5.499000761432086914e-20 4.460000000000000000e+02 5.497716950922173965e-20 4.480000000000000000e+02 5.494354975489675846e-20 4.500000000000000000e+02 5.480290557387929340e-20 4.520000000000000000e+02 5.469605658503043265e-20 4.540000000000000000e+02 5.452297659301701529e-20 4.560000000000000000e+02 5.467148211204015598e-20 4.580000000000000000e+02 5.466148585457995873e-20 4.600000000000000000e+02 5.447658724720393356e-20 4.620000000000000000e+02 5.462536573447516908e-20 4.640000000000000000e+02 5.476334053973460043e-20 4.660000000000000000e+02 5.508914959868449961e-20 4.680000000000000000e+02 5.557297327391618409e-20 4.700000000000000000e+02 5.652176149002808524e-20 4.720000000000000000e+02 5.739241100783158996e-20 4.740000000000000000e+02 5.844711108631135833e-20 4.760000000000000000e+02 6.000495180964504503e-20 4.780000000000000000e+02 6.136630814398098701e-20 4.800000000000000000e+02 6.317070597005838579e-20 4.820000000000000000e+02 6.592465808149774445e-20 4.840000000000000000e+02 6.949589674935642891e-20 4.860000000000000000e+02 7.388883961313677640e-20 4.880000000000000000e+02 7.950770900166198289e-20 4.900000000000000000e+02 7.874131218671731196e-20 4.920000000000000000e+02 8.593652828615606677e-20 4.940000000000000000e+02 9.665921054538875205e-20 4.960000000000000000e+02 1.142782526531881911e-19 4.980000000000000000e+02 1.548503749416090765e-19 5.000000000000000000e+02 3.469379933866449255e-19 5.020000000000000000e+02 7.380962167355412310e-19 5.040000000000000000e+02 2.002805050160922160e-18 5.060000000000000000e+02 3.280412471065789124e-18 5.080000000000000000e+02 2.709398967835517269e-17 5.100000000000000000e+02 9.966452602984558590e-17 5.120000000000000000e+02 8.257303170468236685e-17 5.140000000000000000e+02 1.128600774931229543e-17 5.160000000000000000e+02 2.015176219116535744e-18 5.180000000000000000e+02 7.080713620839345840e-19 5.200000000000000000e+02 3.379723561858448919e-19 5.220000000000000000e+02 1.976975573646314974e-19 5.240000000000000000e+02 1.383702634178897924e-19 5.260000000000000000e+02 1.114702099115580415e-19 5.280000000000000000e+02 9.828809317503152614e-20 5.300000000000000000e+02 8.724392374618727725e-20 5.320000000000000000e+02 7.767513810355947489e-20 5.340000000000000000e+02 7.288049434029248170e-20 5.360000000000000000e+02 6.921932803898251534e-20 5.380000000000000000e+02 6.852101560553072103e-20 5.400000000000000000e+02 6.941183688969638008e-20 5.420000000000000000e+02 6.708236478519681124e-20 5.440000000000000000e+02 6.595648643975755782e-20 5.460000000000000000e+02 6.554659454309002988e-20 5.480000000000000000e+02 6.533840055259534637e-20 5.500000000000000000e+02 6.544419700471891053e-20 5.520000000000000000e+02 6.666702761182914134e-20 5.540000000000000000e+02 6.742792402939501447e-20 5.560000000000000000e+02 6.644740482852659241e-20 5.580000000000000000e+02 6.990896750398654502e-20 5.600000000000000000e+02 7.027934346681480762e-20 5.620000000000000000e+02 6.710585166062678951e-20 5.640000000000000000e+02 6.585810064719947118e-20 5.660000000000000000e+02 6.588482187701413671e-20 5.680000000000000000e+02 6.587473588500150885e-20 5.700000000000000000e+02 6.598819881744625407e-20 5.720000000000000000e+02 6.643003465805698394e-20 5.740000000000000000e+02 6.949075451880126536e-20 5.760000000000000000e+02 6.884457866709075251e-20 5.780000000000000000e+02 6.630477666233437428e-20 5.800000000000000000e+02 6.593467917364021493e-20 5.820000000000000000e+02 6.595057559119879535e-20 5.840000000000000000e+02 6.602013581507723471e-20 5.860000000000000000e+02 6.600389288445623567e-20 5.880000000000000000e+02 6.612757138976254828e-20 5.900000000000000000e+02 6.617671563532042935e-20 5.920000000000000000e+02 6.633961686034855271e-20 5.940000000000000000e+02 6.627495718952100924e-20 5.960000000000000000e+02 6.636077799010662277e-20 5.980000000000000000e+02 7.197284796041638080e-20 6.000000000000000000e+02 7.536969331253002641e-20 6.020000000000000000e+02 6.783234525993449567e-20 6.040000000000000000e+02 6.987608979357709359e-20 6.060000000000000000e+02 7.415121305760870608e-20 6.080000000000000000e+02 7.038809797286249951e-20 6.100000000000000000e+02 6.676005047691982195e-20 6.120000000000000000e+02 6.671626019208650537e-20 6.140000000000000000e+02 6.681649619302073123e-20 6.160000000000000000e+02 6.674823498535295510e-20 6.180000000000000000e+02 6.698501022646979853e-20 6.200000000000000000e+02 6.689876534987435410e-20 6.220000000000000000e+02 6.718899497257366398e-20 6.240000000000000000e+02 6.735668290700546556e-20 6.260000000000000000e+02 6.753014578917421362e-20 6.280000000000000000e+02 6.752293747869140131e-20 6.300000000000000000e+02 6.729496507637950685e-20 6.320000000000000000e+02 6.779380355306496197e-20 6.340000000000000000e+02 6.802369327633654858e-20 6.360000000000000000e+02 6.817288121897374230e-20 6.380000000000000000e+02 6.816434619312084734e-20 6.400000000000000000e+02 6.824749229658541762e-20 6.420000000000000000e+02 6.802518048332788844e-20 6.440000000000000000e+02 6.818721215307419014e-20 6.460000000000000000e+02 6.839406701080511263e-20 6.480000000000000000e+02 6.853429877989196357e-20 6.500000000000000000e+02 6.826859439021254186e-20 6.520000000000000000e+02 6.881705910910512081e-20 6.540000000000000000e+02 6.919261939883681636e-20 6.560000000000000000e+02 6.927658679691759833e-20 6.580000000000000000e+02 6.918114473712607399e-20 6.600000000000000000e+02 7.025447171179629422e-20 6.620000000000000000e+02 6.979774325415024036e-20 6.640000000000000000e+02 6.978947206860227437e-20 6.660000000000000000e+02 7.004376153745113664e-20 6.680000000000000000e+02 6.994785891727896030e-20 6.700000000000000000e+02 7.000060486755903913e-20 6.720000000000000000e+02 7.016347598795495275e-20 6.740000000000000000e+02 7.047194369482199538e-20 6.760000000000000000e+02 7.053779484880274221e-20 6.780000000000000000e+02 7.039192097238396781e-20 6.800000000000000000e+02 7.078623306164536362e-20 6.820000000000000000e+02 7.105946702181841454e-20 6.840000000000000000e+02 7.100695945127578090e-20 6.860000000000000000e+02 7.119500000386669138e-20 6.880000000000000000e+02 7.148235909902455050e-20 6.900000000000000000e+02 7.160353376506560998e-20 6.920000000000000000e+02 7.148082267362529306e-20 6.940000000000000000e+02 7.180513756479701571e-20 6.960000000000000000e+02 7.201289074716806502e-20 6.980000000000000000e+02 7.217154045979108070e-20 7.000000000000000000e+02 7.240594865498031405e-20 7.020000000000000000e+02 7.240290353482317965e-20 7.040000000000000000e+02 7.283675933434671865e-20 7.060000000000000000e+02 7.313873729759235485e-20 7.080000000000000000e+02 7.298746383341312422e-20 7.100000000000000000e+02 7.314041502379053888e-20 7.120000000000000000e+02 7.329577473930579907e-20 7.140000000000000000e+02 7.352859864088267552e-20 7.160000000000000000e+02 7.372741161846555929e-20 7.180000000000000000e+02 7.381415056787921291e-20 7.200000000000000000e+02 7.412539617205708939e-20 7.220000000000000000e+02 7.417258272580164435e-20 7.240000000000000000e+02 7.435588649683949851e-20 7.260000000000000000e+02 7.449857102208066653e-20 7.280000000000000000e+02 7.467519619487082289e-20 7.300000000000000000e+02 7.494636813796185961e-20 7.320000000000000000e+02 7.517191831027988552e-20 7.340000000000000000e+02 7.517845359318444875e-20 7.360000000000000000e+02 7.536362394053664761e-20 7.380000000000000000e+02 7.583199127640194064e-20 7.400000000000000000e+02 7.588786233752002514e-20 7.420000000000000000e+02 7.613417223902848039e-20 7.440000000000000000e+02 7.604518223184246538e-20 7.460000000000000000e+02 7.626986924185481138e-20 7.480000000000000000e+02 7.648169062549307129e-20 7.500000000000000000e+02 7.677467259096048518e-20 7.520000000000000000e+02 7.712633016085625795e-20 7.540000000000000000e+02 7.723981422366317510e-20 7.560000000000000000e+02 7.749013094336808805e-20 7.580000000000000000e+02 7.723867959025739176e-20 7.600000000000000000e+02 7.758496155280673891e-20 7.620000000000000000e+02 7.755625303320047059e-20 7.640000000000000000e+02 7.794860456352764599e-20 7.660000000000000000e+02 7.792621148242851422e-20 7.680000000000000000e+02 7.802845948724487375e-20 7.700000000000000000e+02 7.833765399662538098e-20 7.720000000000000000e+02 7.886306251507765637e-20 7.740000000000000000e+02 7.880895064878983963e-20 7.760000000000000000e+02 7.844373732691242140e-20 7.780000000000000000e+02 7.895562296472859216e-20 7.800000000000000000e+02 7.932747185997071344e-20 7.820000000000000000e+02 7.992942918280236365e-20 7.840000000000000000e+02 7.970817373303003691e-20 7.860000000000000000e+02 7.959274589130104981e-20 7.880000000000000000e+02 8.017642867661404054e-20 7.900000000000000000e+02 8.033647463738400265e-20 7.920000000000000000e+02 8.011638649976065284e-20 7.940000000000000000e+02 8.043196687684854283e-20 7.960000000000000000e+02 8.049488448053361943e-20 7.980000000000000000e+02 8.091786823407023475e-20 8.000000000000000000e+02 8.081870055920390926e-20 8.020000000000000000e+02 8.101295322690788731e-20 8.040000000000000000e+02 8.135493956420048511e-20 8.060000000000000000e+02 8.140027635702910021e-20 8.080000000000000000e+02 8.153067132175343775e-20 8.100000000000000000e+02 8.195020572645131412e-20 8.120000000000000000e+02 8.215872650669042181e-20 8.140000000000000000e+02 8.254476818023041806e-20 8.160000000000000000e+02 8.283174866616655459e-20 8.180000000000000000e+02 8.300220164445057031e-20 8.200000000000000000e+02 8.358856090490940025e-20 8.220000000000000000e+02 8.372803578679412308e-20 8.240000000000000000e+02 8.343987395542235965e-20 8.260000000000000000e+02 8.378003093607882362e-20 8.280000000000000000e+02 8.532619197866175963e-20 8.300000000000000000e+02 8.843051229101302163e-20 8.320000000000000000e+02 8.607269467851468756e-20 8.340000000000000000e+02 8.471935451063730109e-20 8.360000000000000000e+02 8.822394691521801096e-20 8.380000000000000000e+02 9.573989797033417613e-20 8.400000000000000000e+02 9.376932200526113262e-20 8.420000000000000000e+02 8.779241603448636600e-20 8.440000000000000000e+02 8.561673357955773932e-20 8.460000000000000000e+02 8.520425598155593694e-20 8.480000000000000000e+02 8.529202677629541074e-20 8.500000000000000000e+02 8.521469874936435592e-20 8.520000000000000000e+02 8.561097092621212663e-20 8.540000000000000000e+02 8.592489617903049440e-20 8.560000000000000000e+02 8.593506456322428854e-20 8.580000000000000000e+02 8.648453967361423805e-20 8.600000000000000000e+02 8.960930590010073437e-20 8.620000000000000000e+02 9.392605119168089711e-20 8.640000000000000000e+02 9.032416955617218219e-20 8.660000000000000000e+02 8.693656362235204298e-20 8.680000000000000000e+02 8.690598307731544462e-20 8.700000000000000000e+02 8.713792631581864517e-20 8.720000000000000000e+02 8.703937518108841580e-20 8.740000000000000000e+02 8.717955355169186354e-20 8.760000000000000000e+02 8.741955396369587634e-20 8.780000000000000000e+02 8.753522975089484534e-20 8.800000000000000000e+02 8.775208459654317461e-20 8.820000000000000000e+02 8.769454622808587378e-20 8.840000000000000000e+02 8.809425976630945182e-20 8.860000000000000000e+02 8.823175551462711301e-20 8.880000000000000000e+02 8.812485603441925830e-20 8.900000000000000000e+02 8.845436968721983109e-20 8.920000000000000000e+02 8.870529017796016682e-20 8.940000000000000000e+02 8.874392878062492031e-20 8.960000000000000000e+02 8.885239854350176099e-20 8.980000000000000000e+02 8.980131608912918930e-20 9.000000000000000000e+02 9.036274510177797982e-20 9.020000000000000000e+02 8.978434326930209729e-20 9.040000000000000000e+02 8.980523305984222150e-20 9.060000000000000000e+02 9.013324664534786301e-20 9.080000000000000000e+02 8.972725579878289329e-20 9.100000000000000000e+02 9.058347676838577513e-20 9.120000000000000000e+02 8.990969159396957776e-20 9.140000000000000000e+02 9.051115081269145934e-20 9.160000000000000000e+02 9.053983602749885024e-20 9.180000000000000000e+02 9.052297842708849460e-20 9.200000000000000000e+02 9.064740419284203054e-20 9.220000000000000000e+02 9.087591217799698393e-20 9.240000000000000000e+02 9.090948707787832335e-20 9.260000000000000000e+02 9.128418776615670668e-20 9.280000000000000000e+02 9.135532251940385387e-20 9.300000000000000000e+02 9.156292227154119255e-20 9.320000000000000000e+02 9.168772277401852573e-20 9.340000000000000000e+02 9.172534011824939678e-20 9.360000000000000000e+02 9.205731378083101026e-20 9.380000000000000000e+02 9.200299365839180503e-20 9.400000000000000000e+02 9.204074996245251545e-20 9.420000000000000000e+02 9.213712752394860155e-20 9.440000000000000000e+02 9.266321255815389115e-20 9.460000000000000000e+02 9.274969845814072361e-20 9.480000000000000000e+02 9.278429454589114823e-20 9.500000000000000000e+02 9.343329181518103536e-20 9.520000000000000000e+02 9.381209430986694657e-20 9.540000000000000000e+02 9.347785914235077828e-20 9.560000000000000000e+02 9.368579122294925138e-20 9.580000000000000000e+02 9.377009030263543292e-20 9.600000000000000000e+02 9.410490078797147938e-20 9.620000000000000000e+02 9.432590394094647756e-20 9.640000000000000000e+02 9.419099019266948009e-20 9.660000000000000000e+02 9.458695678989542516e-20 9.680000000000000000e+02 9.463382811888808450e-20 9.700000000000000000e+02 9.461571289002301304e-20 9.720000000000000000e+02 9.464982179758943499e-20 9.740000000000000000e+02 9.473766534061946138e-20 9.760000000000000000e+02 9.545609529180236355e-20 9.780000000000000000e+02 9.557138842276846587e-20 9.800000000000000000e+02 9.588424346087083980e-20 9.820000000000000000e+02 9.597350949212195988e-20 9.840000000000000000e+02 9.607366404438001031e-20 9.860000000000000000e+02 9.614478028687136992e-20 9.880000000000000000e+02 9.605202756507076947e-20 9.900000000000000000e+02 9.729168280957745993e-20 9.920000000000000000e+02 9.848696226920393445e-20 9.940000000000000000e+02 1.025826209723019206e-19 9.960000000000000000e+02 1.628477721188264131e-19 9.980000000000000000e+02 2.709846156352858014e-18 1.000000000000000000e+03 6.891817926252896337e-18 1.002000000000000000e+03 4.302799253149859884e-18 1.004000000000000000e+03 2.437586075891202756e-19 1.006000000000000000e+03 1.119804514017374410e-19 1.008000000000000000e+03 1.042797003258326770e-19 1.010000000000000000e+03 1.115847021404260720e-19 1.012000000000000000e+03 1.065210248880514894e-19 1.014000000000000000e+03 9.977576678659046217e-20 1.016000000000000000e+03 1.004296131879320541e-19 1.018000000000000000e+03 1.057749601076216657e-19 1.020000000000000000e+03 1.086514204205416299e-19 1.022000000000000000e+03 1.120470533931269190e-19 1.024000000000000000e+03 1.008693114157974474e-19 1.026000000000000000e+03 9.986266486419998191e-20 1.028000000000000000e+03 9.978446861729399155e-20 1.030000000000000000e+03 1.000367948768952943e-19 1.032000000000000000e+03 1.001371339257900283e-19 1.034000000000000000e+03 1.000959215844952486e-19 1.036000000000000000e+03 1.000675129360098053e-19 1.038000000000000000e+03 1.003824766222188939e-19 1.040000000000000000e+03 1.007865538275899178e-19 1.042000000000000000e+03 1.009364579572920927e-19 1.044000000000000000e+03 1.010089620441289716e-19 1.046000000000000000e+03 1.013500671445635898e-19 1.048000000000000000e+03 1.014885483473071837e-19 1.050000000000000000e+03 1.017869769603274073e-19 1.052000000000000000e+03 1.016949131339948227e-19 1.054000000000000000e+03 1.022307343324476174e-19 1.056000000000000000e+03 1.017547417384942815e-19 1.058000000000000000e+03 1.020118208039170937e-19 1.060000000000000000e+03 1.025593497270281631e-19 1.062000000000000000e+03 1.028445053551553609e-19 1.064000000000000000e+03 1.032499319604816851e-19 1.066000000000000000e+03 1.027819607344611122e-19 1.068000000000000000e+03 1.031618878239825371e-19 1.070000000000000000e+03 1.032813773296981152e-19 1.072000000000000000e+03 1.036358006623125260e-19 1.074000000000000000e+03 1.035484906344239989e-19 1.076000000000000000e+03 1.044679312762053635e-19 1.078000000000000000e+03 1.044284612639191452e-19 1.080000000000000000e+03 1.049951060958199414e-19 1.082000000000000000e+03 1.436209724098147926e-19 1.084000000000000000e+03 1.967451942178859979e-19 1.086000000000000000e+03 1.212007560717755743e-19 1.088000000000000000e+03 1.055372343917318996e-19 1.090000000000000000e+03 1.051542609611228836e-19 1.092000000000000000e+03 1.052835042326125025e-19 1.094000000000000000e+03 1.055424150695255159e-19 1.096000000000000000e+03 1.060101601226105734e-19 1.098000000000000000e+03 1.061647229043881880e-19 1.100000000000000000e+03 1.062356959649232034e-19 1.102000000000000000e+03 1.063504390906529562e-19 1.104000000000000000e+03 1.064449597271850880e-19 1.106000000000000000e+03 1.072984075007206276e-19 1.108000000000000000e+03 1.068930209151925206e-19 1.110000000000000000e+03 1.074523324220170120e-19 1.112000000000000000e+03 1.073794525820535605e-19 1.114000000000000000e+03 1.078793847571800130e-19 1.116000000000000000e+03 1.084225652058175795e-19 1.118000000000000000e+03 1.100226685579770904e-19 1.120000000000000000e+03 1.093723290395172657e-19 1.122000000000000000e+03 1.082155242358649461e-19 1.124000000000000000e+03 1.080313975817710409e-19 1.126000000000000000e+03 1.080275297300661300e-19 1.128000000000000000e+03 1.084674381317887020e-19 1.130000000000000000e+03 1.086367567960316072e-19 1.132000000000000000e+03 1.083515118088346751e-19 1.134000000000000000e+03 1.087446386690925141e-19 1.136000000000000000e+03 1.091223678362146754e-19 1.138000000000000000e+03 1.091829310051901942e-19 1.140000000000000000e+03 1.095167836381707701e-19 1.142000000000000000e+03 1.095131789579089685e-19 1.144000000000000000e+03 1.096702129715503480e-19 1.146000000000000000e+03 1.095702523424768478e-19 1.148000000000000000e+03 1.112606132550638152e-19 1.150000000000000000e+03 1.131822240598030768e-19 1.152000000000000000e+03 1.579103284593092344e-19 1.154000000000000000e+03 1.667454867751331258e-19 1.156000000000000000e+03 1.140991554758748290e-19 1.158000000000000000e+03 1.110987631183573811e-19 1.160000000000000000e+03 1.111047104302030031e-19 1.162000000000000000e+03 1.120556955961870619e-19 1.164000000000000000e+03 1.117994393312614496e-19 1.166000000000000000e+03 1.119439015205476882e-19 1.168000000000000000e+03 1.117895352744199970e-19 1.170000000000000000e+03 1.120376726590962150e-19 1.172000000000000000e+03 1.122758554258236511e-19 1.174000000000000000e+03 1.121695871939333136e-19 1.176000000000000000e+03 1.122164434305672687e-19 1.178000000000000000e+03 1.122071267867396226e-19 1.180000000000000000e+03 1.126988283755208306e-19 1.182000000000000000e+03 1.127932096480317084e-19 1.184000000000000000e+03 1.127362448976216965e-19 1.186000000000000000e+03 1.133498705477416547e-19 1.188000000000000000e+03 1.136920384428956376e-19 1.190000000000000000e+03 1.134975830560796649e-19 1.192000000000000000e+03 1.141093901850901781e-19 1.194000000000000000e+03 1.136651245946420377e-19 1.196000000000000000e+03 1.137194567280105121e-19 1.198000000000000000e+03 1.144621891499835609e-19 1.200000000000000000e+03 1.146233060078212961e-19 1.202000000000000000e+03 1.150102130604025040e-19 1.204000000000000000e+03 1.150500460248619190e-19 1.206000000000000000e+03 1.152028126385123718e-19 1.208000000000000000e+03 1.153598471115374913e-19 1.210000000000000000e+03 1.152583327528367811e-19 1.212000000000000000e+03 1.153309376979913671e-19 1.214000000000000000e+03 1.160295218872751672e-19 1.216000000000000000e+03 1.159285178537928658e-19 1.218000000000000000e+03 1.161230926604645438e-19 1.220000000000000000e+03 1.164876550667361821e-19 1.222000000000000000e+03 1.164435005843789380e-19 1.224000000000000000e+03 1.165279461112709332e-19 1.226000000000000000e+03 1.170128052203209216e-19 1.228000000000000000e+03 1.171438234216591997e-19 1.230000000000000000e+03 1.170612586799205414e-19 1.232000000000000000e+03 1.174923527537048747e-19 1.234000000000000000e+03 1.174648838476407775e-19 1.236000000000000000e+03 1.174768579230027107e-19 1.238000000000000000e+03 1.178386655122727241e-19 1.240000000000000000e+03 1.179572255440632285e-19 1.242000000000000000e+03 1.184191661301736974e-19 1.244000000000000000e+03 1.182048145543901555e-19 1.246000000000000000e+03 1.186159482873657498e-19 1.248000000000000000e+03 1.186885500015099646e-19 1.250000000000000000e+03 1.186306342827572272e-19 1.252000000000000000e+03 1.190346444393029942e-19 1.254000000000000000e+03 1.191882333919432443e-19 1.256000000000000000e+03 1.192720069003454811e-19 1.258000000000000000e+03 1.193272934292533504e-19 1.260000000000000000e+03 1.197330911906562999e-19 1.262000000000000000e+03 1.199070905309328859e-19 1.264000000000000000e+03 1.201398626059489899e-19 1.266000000000000000e+03 1.201937037756452053e-19 1.268000000000000000e+03 1.201055506024711065e-19 1.270000000000000000e+03 1.207117922782414511e-19 1.272000000000000000e+03 1.205806773061839345e-19 1.274000000000000000e+03 1.210153501875560323e-19 1.276000000000000000e+03 1.210956554028602640e-19 1.278000000000000000e+03 1.212858223360329760e-19 1.280000000000000000e+03 1.217392222923142332e-19 1.282000000000000000e+03 1.217944764902108567e-19 1.284000000000000000e+03 1.218312912068480454e-19 1.286000000000000000e+03 1.219195379127486489e-19 1.288000000000000000e+03 1.217388957830958295e-19 1.290000000000000000e+03 1.221187884366549537e-19 1.292000000000000000e+03 1.223286251173165582e-19 1.294000000000000000e+03 1.221723564509044531e-19 1.296000000000000000e+03 1.227319437941686424e-19 1.298000000000000000e+03 1.231394319059659598e-19 1.300000000000000000e+03 1.233864859909672461e-19 1.302000000000000000e+03 1.232520195587009116e-19 1.304000000000000000e+03 1.232949677621462364e-19 1.306000000000000000e+03 1.235034550503105479e-19 1.308000000000000000e+03 1.237394300875768579e-19 1.310000000000000000e+03 1.239928051975273054e-19 1.312000000000000000e+03 1.241244316454555890e-19 1.314000000000000000e+03 1.247308124457097952e-19 1.316000000000000000e+03 1.247405428092841935e-19 1.318000000000000000e+03 1.247812291577008146e-19 1.320000000000000000e+03 1.246406089771631868e-19 1.322000000000000000e+03 1.248978111695792124e-19 1.324000000000000000e+03 1.254148542954390140e-19 1.326000000000000000e+03 1.254173925139388069e-19 1.328000000000000000e+03 1.252532067503859772e-19 1.330000000000000000e+03 1.252560847020570064e-19 1.332000000000000000e+03 1.255315249519643600e-19 1.334000000000000000e+03 1.261835531245526485e-19 1.336000000000000000e+03 1.260820157356456765e-19 1.338000000000000000e+03 1.262967837516992062e-19 1.340000000000000000e+03 1.263661547206162291e-19 1.342000000000000000e+03 1.266008654561890921e-19 1.344000000000000000e+03 1.268794975107338064e-19 1.346000000000000000e+03 1.270518250765679110e-19 1.348000000000000000e+03 1.273215774443343475e-19 1.350000000000000000e+03 1.271363933025578888e-19 1.352000000000000000e+03 1.276663188609963815e-19 1.354000000000000000e+03 1.281345313481541385e-19 1.356000000000000000e+03 1.280201754213278695e-19 1.358000000000000000e+03 1.279056544044266098e-19 1.360000000000000000e+03 1.286887423860419096e-19 1.362000000000000000e+03 1.284274203104444722e-19 1.364000000000000000e+03 1.291583428845119972e-19 1.366000000000000000e+03 1.288078223039794161e-19 1.368000000000000000e+03 1.291223551612783282e-19 1.370000000000000000e+03 1.294910607658314050e-19 1.372000000000000000e+03 1.294135036091610265e-19 1.374000000000000000e+03 1.293288250223600026e-19 1.376000000000000000e+03 1.294033621461420507e-19 1.378000000000000000e+03 1.298128803725497353e-19 1.380000000000000000e+03 1.302483788215838503e-19 1.382000000000000000e+03 1.304200167387949444e-19 1.384000000000000000e+03 1.308200093490051796e-19 1.386000000000000000e+03 1.309506034871172998e-19 1.388000000000000000e+03 1.309088402485513446e-19 1.390000000000000000e+03 1.307513080562432112e-19 1.392000000000000000e+03 1.315492078711733202e-19 1.394000000000000000e+03 1.312644924654995280e-19 1.396000000000000000e+03 1.321871940204677116e-19 1.398000000000000000e+03 1.328977874243645983e-19 1.400000000000000000e+03 1.322810969809519392e-19 1.402000000000000000e+03 1.319792341240149070e-19 1.404000000000000000e+03 1.325226434930234114e-19 1.406000000000000000e+03 1.325250695013090402e-19 1.408000000000000000e+03 1.322244205577770678e-19 1.410000000000000000e+03 1.323648839886411071e-19 1.412000000000000000e+03 1.319928656184002690e-19 1.414000000000000000e+03 1.331254956247329574e-19 1.416000000000000000e+03 1.331519301389904360e-19 1.418000000000000000e+03 1.334394106434176392e-19 1.420000000000000000e+03 1.340377319617826862e-19 1.422000000000000000e+03 1.339751558935840481e-19 1.424000000000000000e+03 1.339046383428710587e-19 1.426000000000000000e+03 1.340366434635016057e-19 1.428000000000000000e+03 1.341016609344908341e-19 1.430000000000000000e+03 1.346822974681833593e-19 1.432000000000000000e+03 1.347013888315839675e-19 1.434000000000000000e+03 1.349647096671056985e-19 1.436000000000000000e+03 1.353373550584769634e-19 1.438000000000000000e+03 1.355028652078316078e-19 1.440000000000000000e+03 1.350469765973845867e-19 1.442000000000000000e+03 1.356135852606389262e-19 1.444000000000000000e+03 1.359777466947794733e-19 1.446000000000000000e+03 1.362774471220303215e-19 1.448000000000000000e+03 1.367006263787035004e-19 1.450000000000000000e+03 1.366696205708859551e-19 1.452000000000000000e+03 1.379011733751976749e-19 1.454000000000000000e+03 1.448975988869206014e-19 1.456000000000000000e+03 1.964735520009422179e-19 1.458000000000000000e+03 8.797303049906777744e-19 1.460000000000000000e+03 7.593058698524539258e-18 1.462000000000000000e+03 1.101983397360079529e-17 1.464000000000000000e+03 6.955737090500222633e-18 1.466000000000000000e+03 7.071435160040130568e-18 1.468000000000000000e+03 1.031885092303000243e-17 1.470000000000000000e+03 9.092063416223597069e-18 1.472000000000000000e+03 1.268697377250350733e-17 1.474000000000000000e+03 1.001235851105396756e-17 1.476000000000000000e+03 1.338322764563703805e-18 1.478000000000000000e+03 2.631888874746557415e-19 1.480000000000000000e+03 1.403557589141620420e-18 1.482000000000000000e+03 2.727934973985049259e-18 1.484000000000000000e+03 1.342860755564933450e-18 1.486000000000000000e+03 1.399911663690975508e-19 1.488000000000000000e+03 1.409711159586963330e-19 1.490000000000000000e+03 2.628545030051329838e-18 1.492000000000000000e+03 5.376863708247719902e-18 1.494000000000000000e+03 3.470775320265893292e-18 1.496000000000000000e+03 3.669855585358665916e-18 1.498000000000000000e+03 4.260338117080726718e-18 1.500000000000000000e+03 2.908019363905719679e-18 1.502000000000000000e+03 1.158095178885654481e-18 1.504000000000000000e+03 1.597671142411525150e-19 1.506000000000000000e+03 1.428921181321345586e-19 1.508000000000000000e+03 1.414003020219620958e-19 1.510000000000000000e+03 1.413175359433517490e-19 1.512000000000000000e+03 1.416775546035918801e-19 1.514000000000000000e+03 1.420254091389388665e-19 1.516000000000000000e+03 1.419260467501420696e-19 1.518000000000000000e+03 1.422717884858036013e-19 1.520000000000000000e+03 1.420978519796279227e-19 1.522000000000000000e+03 1.422757561963967488e-19 1.524000000000000000e+03 1.428279755253778919e-19 1.526000000000000000e+03 1.427516702030178564e-19 1.528000000000000000e+03 1.425288945898301399e-19 1.530000000000000000e+03 1.452870137337532534e-19 1.532000000000000000e+03 1.517870950308215347e-19 1.534000000000000000e+03 1.469307946300618616e-19 1.536000000000000000e+03 1.434642146024637984e-19 1.538000000000000000e+03 1.436138257238404768e-19 1.540000000000000000e+03 1.440910322930633534e-19 1.542000000000000000e+03 1.441208306811376120e-19 1.544000000000000000e+03 1.443112175865335508e-19 1.546000000000000000e+03 1.443931014257569400e-19 1.548000000000000000e+03 1.447944315392350613e-19 1.550000000000000000e+03 1.449625730006094850e-19 1.552000000000000000e+03 1.450186311341400348e-19 1.554000000000000000e+03 1.451503899990682719e-19 1.556000000000000000e+03 1.455279750324581438e-19 1.558000000000000000e+03 1.457123679477839236e-19 1.560000000000000000e+03 1.459765449728921221e-19 1.562000000000000000e+03 1.455481922073819591e-19 1.564000000000000000e+03 1.459245169955802702e-19 1.566000000000000000e+03 1.458657281114834379e-19 1.568000000000000000e+03 1.465635645972261273e-19 1.570000000000000000e+03 1.467399521445628012e-19 1.572000000000000000e+03 1.473346807349755814e-19 1.574000000000000000e+03 1.468733596364630409e-19 1.576000000000000000e+03 1.470933495100766902e-19 1.578000000000000000e+03 1.481234861077341097e-19 1.580000000000000000e+03 1.472423735618918046e-19 1.582000000000000000e+03 1.473301642980478751e-19 1.584000000000000000e+03 1.478807373321810890e-19 1.586000000000000000e+03 1.474147409132161033e-19 1.588000000000000000e+03 1.481565249851017469e-19 1.590000000000000000e+03 1.483248473690128329e-19 1.592000000000000000e+03 1.483063921268551425e-19 1.594000000000000000e+03 1.484687844484458533e-19 1.596000000000000000e+03 1.490071472107153182e-19 1.598000000000000000e+03 1.490538398774460322e-19 1.600000000000000000e+03 1.484788864900981966e-19 1.602000000000000000e+03 1.495464759960335241e-19 1.604000000000000000e+03 1.499498800834245919e-19 1.606000000000000000e+03 1.494661816830635662e-19 1.608000000000000000e+03 1.499750617608839524e-19 1.610000000000000000e+03 1.497099689949073011e-19 1.612000000000000000e+03 1.505498891843847769e-19 1.614000000000000000e+03 1.506166946584707687e-19 1.616000000000000000e+03 1.504035312785018322e-19 1.618000000000000000e+03 1.507281907267248691e-19 1.620000000000000000e+03 1.508655835461878974e-19 1.622000000000000000e+03 1.511197338458443724e-19 1.624000000000000000e+03 1.516888652646108450e-19 1.626000000000000000e+03 1.516335148171274796e-19 1.628000000000000000e+03 1.515859151898630310e-19 1.630000000000000000e+03 1.519223774314326945e-19 1.632000000000000000e+03 1.517213815410348045e-19 1.634000000000000000e+03 1.522274953174490962e-19 1.636000000000000000e+03 1.527851961498631981e-19 1.638000000000000000e+03 1.531548528728058673e-19 1.640000000000000000e+03 1.533318665054330579e-19 1.642000000000000000e+03 1.537726717263856703e-19 1.644000000000000000e+03 1.532765068149250625e-19 1.646000000000000000e+03 1.529773414007077879e-19 1.648000000000000000e+03 1.529840043728700272e-19 1.650000000000000000e+03 1.534255009105389546e-19 1.652000000000000000e+03 1.542875004200898883e-19 1.654000000000000000e+03 1.545584755222567693e-19 1.656000000000000000e+03 1.543663871073498031e-19 1.658000000000000000e+03 1.541176112567231934e-19 1.660000000000000000e+03 1.543309343277461260e-19 1.662000000000000000e+03 1.543570808934763950e-19 1.664000000000000000e+03 1.548492324345735101e-19 1.666000000000000000e+03 1.550675174154953155e-19 1.668000000000000000e+03 1.557449414847030838e-19 1.670000000000000000e+03 1.554902495847556649e-19 1.672000000000000000e+03 1.559480418305867314e-19 1.674000000000000000e+03 1.554719189131622157e-19 1.676000000000000000e+03 1.556340757156324500e-19 1.678000000000000000e+03 1.565397124503808295e-19 1.680000000000000000e+03 1.556606398309887455e-19 1.682000000000000000e+03 1.564360142548752694e-19 1.684000000000000000e+03 1.564690484623312258e-19 1.686000000000000000e+03 1.566001569767062054e-19 1.688000000000000000e+03 1.567349262234940008e-19 1.690000000000000000e+03 1.572340286016843478e-19 1.692000000000000000e+03 1.573074730429948757e-19 1.694000000000000000e+03 1.575890180403072284e-19 1.696000000000000000e+03 1.577894607481924210e-19 1.698000000000000000e+03 1.580047110790009582e-19 1.700000000000000000e+03 1.578317533547147474e-19 1.702000000000000000e+03 1.576969951054800207e-19 1.704000000000000000e+03 1.579224170845510579e-19 1.706000000000000000e+03 1.586198681110010384e-19 1.708000000000000000e+03 1.587251084075419695e-19 1.710000000000000000e+03 1.586329765661962324e-19 1.712000000000000000e+03 1.589341487932198418e-19 1.714000000000000000e+03 1.593264466028826658e-19 1.716000000000000000e+03 1.594050319709720379e-19 1.718000000000000000e+03 1.595170252304245299e-19 1.720000000000000000e+03 1.600852207499035297e-19 1.722000000000000000e+03 1.598216891669691288e-19 1.724000000000000000e+03 1.604100002155961910e-19 1.726000000000000000e+03 1.602951343781948173e-19 1.728000000000000000e+03 1.601510349968838255e-19 1.730000000000000000e+03 1.605119848989276541e-19 1.732000000000000000e+03 1.604196564660907261e-19 1.734000000000000000e+03 1.609036605996483265e-19 1.736000000000000000e+03 1.610154679946380059e-19 1.738000000000000000e+03 1.614207676614071713e-19 1.740000000000000000e+03 1.615432164537206435e-19 1.742000000000000000e+03 1.617801033067971556e-19 1.744000000000000000e+03 1.621640906623718824e-19 1.746000000000000000e+03 1.619030743966262816e-19 1.748000000000000000e+03 1.616594768297112781e-19 1.750000000000000000e+03 1.621973805685790220e-19 1.752000000000000000e+03 1.630137166084571807e-19 1.754000000000000000e+03 1.627552877928007281e-19 1.756000000000000000e+03 1.627211900640698521e-19 1.758000000000000000e+03 1.632259830315848795e-19 1.760000000000000000e+03 1.638596325013904071e-19 1.762000000000000000e+03 1.634920506867533785e-19 1.764000000000000000e+03 1.635306029977981934e-19 1.766000000000000000e+03 1.637853108178591964e-19 1.768000000000000000e+03 1.634572733502910369e-19 1.770000000000000000e+03 1.638244719703703950e-19 1.772000000000000000e+03 1.643470499871752098e-19 1.774000000000000000e+03 1.645450297237659205e-19 1.776000000000000000e+03 1.647953670342263026e-19 1.778000000000000000e+03 1.645425314512550898e-19 1.780000000000000000e+03 1.648162786873401164e-19 1.782000000000000000e+03 1.652203055920586322e-19 1.784000000000000000e+03 1.655700033630098471e-19 1.786000000000000000e+03 1.656241961846644582e-19 1.788000000000000000e+03 1.656068931153065407e-19 1.790000000000000000e+03 1.659541096691041037e-19 1.792000000000000000e+03 1.660186893668094551e-19 1.794000000000000000e+03 1.659909217965949105e-19 1.796000000000000000e+03 1.661116110904936574e-19 1.798000000000000000e+03 1.664673731057076002e-19 1.800000000000000000e+03 1.665998875148401188e-19 1.802000000000000000e+03 1.667070340433429909e-19 1.804000000000000000e+03 1.660859692946112096e-19 1.806000000000000000e+03 1.669493599247032631e-19 1.808000000000000000e+03 1.670406676481900673e-19 1.810000000000000000e+03 1.668562819379791710e-19 1.812000000000000000e+03 1.672419234230072259e-19 1.814000000000000000e+03 1.678337586123532065e-19 1.816000000000000000e+03 1.675635691655236729e-19 1.818000000000000000e+03 1.677430298034917880e-19 1.820000000000000000e+03 1.686116251669310072e-19 1.822000000000000000e+03 1.691441984790762053e-19 1.824000000000000000e+03 1.684236490181891155e-19 1.826000000000000000e+03 1.686296838062984045e-19 1.828000000000000000e+03 1.693725161666295176e-19 1.830000000000000000e+03 1.693376654995713196e-19 1.832000000000000000e+03 1.698168678222972132e-19 1.834000000000000000e+03 1.701382309000601345e-19 1.836000000000000000e+03 1.692424036073303249e-19 1.838000000000000000e+03 1.704158920912249529e-19 1.840000000000000000e+03 1.702561203112632101e-19 1.842000000000000000e+03 1.705211924123115459e-19 1.844000000000000000e+03 1.700074703722832545e-19 1.846000000000000000e+03 1.705518093440562977e-19 1.848000000000000000e+03 1.711745904199835717e-19 1.850000000000000000e+03 1.708967308870146955e-19 1.852000000000000000e+03 1.711129408625419394e-19 1.854000000000000000e+03 1.716226638697539552e-19 1.856000000000000000e+03 1.719022701162386123e-19 1.858000000000000000e+03 1.721363698357240986e-19 1.860000000000000000e+03 1.727166665068503157e-19 1.862000000000000000e+03 1.725134364022820521e-19 1.864000000000000000e+03 1.718642273000905311e-19 1.866000000000000000e+03 1.725235026812835523e-19 1.868000000000000000e+03 1.725175596559873335e-19 1.870000000000000000e+03 1.727739588657382267e-19 1.872000000000000000e+03 1.725471373616205947e-19 1.874000000000000000e+03 1.726199751850619859e-19 1.876000000000000000e+03 1.728151460660131588e-19 1.878000000000000000e+03 1.730524770819643261e-19 1.880000000000000000e+03 1.729114939104971588e-19 1.882000000000000000e+03 1.737446594055201997e-19 1.884000000000000000e+03 1.737505360848598726e-19 1.886000000000000000e+03 1.733957817353458453e-19 1.888000000000000000e+03 1.735649921942444092e-19 1.890000000000000000e+03 1.738648982879808408e-19 1.892000000000000000e+03 1.740378776751651272e-19 1.894000000000000000e+03 1.740540986740448054e-19 1.896000000000000000e+03 1.745481261415036788e-19 1.898000000000000000e+03 1.748737521976867845e-19 1.900000000000000000e+03 1.752462996076583459e-19 1.902000000000000000e+03 1.756599818466295092e-19 1.904000000000000000e+03 1.757491201790620472e-19 1.906000000000000000e+03 1.756738897009737141e-19 1.908000000000000000e+03 1.756052913411844139e-19 1.910000000000000000e+03 1.762369630707167481e-19 1.912000000000000000e+03 1.761870208638879192e-19 1.914000000000000000e+03 1.765810286515188327e-19 1.916000000000000000e+03 1.770359794159707099e-19 1.918000000000000000e+03 1.775107768283059052e-19 1.920000000000000000e+03 1.944706008729017617e-19 1.922000000000000000e+03 7.294647768439175176e-19 1.924000000000000000e+03 1.023596970151556011e-18 1.926000000000000000e+03 4.878181802153822191e-19 1.928000000000000000e+03 8.340074152345617470e-19 1.930000000000000000e+03 1.085488384061742300e-18 1.932000000000000000e+03 1.641378472681419334e-18 1.934000000000000000e+03 9.492305845746805830e-19 1.936000000000000000e+03 9.695276905506013740e-19 1.938000000000000000e+03 1.337314748550299495e-18 1.940000000000000000e+03 3.279901907563950351e-18 1.942000000000000000e+03 3.127258262387498084e-18 1.944000000000000000e+03 5.997235397223067020e-19 1.946000000000000000e+03 1.935188417249984548e-19 1.948000000000000000e+03 1.805231498660926008e-19 1.950000000000000000e+03 1.805124209421780464e-19 1.952000000000000000e+03 1.997216834213240058e-19 1.954000000000000000e+03 6.601269922745772727e-19 1.956000000000000000e+03 7.507388116380840492e-19 1.958000000000000000e+03 2.790785493011033136e-19 1.960000000000000000e+03 7.269779608750517440e-19 1.962000000000000000e+03 7.128865918531193608e-19 1.964000000000000000e+03 2.185359440770633398e-19 1.966000000000000000e+03 2.890729201053356483e-19 1.968000000000000000e+03 8.967724330374192419e-19 1.970000000000000000e+03 8.209667479471354411e-19 1.972000000000000000e+03 2.774742148379202655e-19 1.974000000000000000e+03 1.829704976201155259e-19 1.976000000000000000e+03 3.018413389621921753e-19 1.978000000000000000e+03 6.518284356743188052e-19 1.980000000000000000e+03 1.152955228849052006e-18 1.982000000000000000e+03 9.480226877713969246e-19 1.984000000000000000e+03 2.136447798745927354e-19 1.986000000000000000e+03 1.838039421387735972e-19 1.988000000000000000e+03 1.827223983082015431e-19 1.990000000000000000e+03 1.838739357870332043e-19 1.992000000000000000e+03 1.841006011536115472e-19 1.994000000000000000e+03 1.838675980158207335e-19 1.996000000000000000e+03 1.839950565014034990e-19 1.998000000000000000e+03 1.836938662919216598e-19 2.000000000000000000e+03 1.838227758269339260e-19 2.002000000000000000e+03 1.842539719584143402e-19 2.004000000000000000e+03 1.843103524305227583e-19 2.006000000000000000e+03 1.852575864011901464e-19 2.008000000000000000e+03 1.848823094251163591e-19 2.010000000000000000e+03 1.845086721136316412e-19 2.012000000000000000e+03 1.842995564329872249e-19 2.014000000000000000e+03 1.850999430923863958e-19 2.016000000000000000e+03 1.854606159096589617e-19 2.018000000000000000e+03 1.853602975712208049e-19 2.020000000000000000e+03 1.856565372258977897e-19 2.022000000000000000e+03 1.858150301837601257e-19 2.024000000000000000e+03 1.866758949378511389e-19 2.026000000000000000e+03 1.860467355107972460e-19 2.028000000000000000e+03 1.857755011009169276e-19 2.030000000000000000e+03 1.865348570040542653e-19 2.032000000000000000e+03 1.866468477458678671e-19 2.034000000000000000e+03 1.872793846084381200e-19 2.036000000000000000e+03 1.870387791707835926e-19 2.038000000000000000e+03 1.870301368672758994e-19 2.040000000000000000e+03 1.886132398315014018e-19 2.042000000000000000e+03 1.956438478210032150e-19 2.044000000000000000e+03 1.939027654981116054e-19 2.046000000000000000e+03 1.876918926336888701e-19 2.048000000000000000e+03 1.880622420973578976e-19 2.050000000000000000e+03 1.883116399694888376e-19 2.052000000000000000e+03 1.886523097130283595e-19 2.054000000000000000e+03 1.888209937951672563e-19 2.056000000000000000e+03 1.891835190738125170e-19 2.058000000000000000e+03 1.887609860530423104e-19 2.060000000000000000e+03 1.891233882785544812e-19 2.062000000000000000e+03 1.893275829464083586e-19 2.064000000000000000e+03 1.895471198213412538e-19 2.066000000000000000e+03 1.896871635137931792e-19 2.068000000000000000e+03 1.897452119684139058e-19 2.070000000000000000e+03 1.897976324316641388e-19 2.072000000000000000e+03 1.905995036067705693e-19 2.074000000000000000e+03 1.904796023797194496e-19 2.076000000000000000e+03 1.908606254958872556e-19 2.078000000000000000e+03 1.908519480756071893e-19 2.080000000000000000e+03 1.903114038568528391e-19 2.082000000000000000e+03 1.904832093376138090e-19 2.084000000000000000e+03 1.911823212597185372e-19 2.086000000000000000e+03 1.910365694953841687e-19 2.088000000000000000e+03 1.916358821080390037e-19 2.090000000000000000e+03 1.923595956199241591e-19 2.092000000000000000e+03 1.922555773228528020e-19 2.094000000000000000e+03 1.919989664516750263e-19 2.096000000000000000e+03 1.920600924587694926e-19 2.098000000000000000e+03 1.928851928945916780e-19 2.100000000000000000e+03 1.926183136002874422e-19 2.102000000000000000e+03 1.924877477297704007e-19 2.104000000000000000e+03 1.926545659232708330e-19 2.106000000000000000e+03 1.934698699353011055e-19 2.108000000000000000e+03 1.936442451249159843e-19 2.110000000000000000e+03 1.938001612164716718e-19 2.112000000000000000e+03 1.934377383638657902e-19 2.114000000000000000e+03 1.936026296548765654e-19 2.116000000000000000e+03 1.941743099268424165e-19 2.118000000000000000e+03 1.942516249511849683e-19 2.120000000000000000e+03 1.949148293547626046e-19 2.122000000000000000e+03 1.949102626174178833e-19 2.124000000000000000e+03 1.947894515423118783e-19 2.126000000000000000e+03 1.953815204168244496e-19 2.128000000000000000e+03 1.949401040946585014e-19 2.130000000000000000e+03 1.951018026657272338e-19 2.132000000000000000e+03 1.954972294247462171e-19 2.134000000000000000e+03 1.957468407597779835e-19 2.136000000000000000e+03 1.956478356036382188e-19 2.138000000000000000e+03 1.957222270730610103e-19 2.140000000000000000e+03 1.964229006380743188e-19 2.142000000000000000e+03 1.963894396527588719e-19 2.144000000000000000e+03 1.964609591744633596e-19 2.146000000000000000e+03 1.977102136850328156e-19 2.148000000000000000e+03 1.970612807177080384e-19 2.150000000000000000e+03 1.966900075271224505e-19 2.152000000000000000e+03 1.977668770411219688e-19 2.154000000000000000e+03 1.977754525016508549e-19 2.156000000000000000e+03 1.981658036944732895e-19 2.158000000000000000e+03 1.975091668946941671e-19 2.160000000000000000e+03 1.987742479052817073e-19 2.162000000000000000e+03 1.986549162008701954e-19 2.164000000000000000e+03 1.982342508109543254e-19 2.166000000000000000e+03 1.991076704547631417e-19 2.168000000000000000e+03 1.990839733704885543e-19 2.170000000000000000e+03 1.989460308966964290e-19 2.172000000000000000e+03 1.986114808714025558e-19 2.174000000000000000e+03 1.993881987666874906e-19 2.176000000000000000e+03 1.991763561603583504e-19 2.178000000000000000e+03 1.996921222377470643e-19 2.180000000000000000e+03 2.003375331441001273e-19 2.182000000000000000e+03 1.994623703528634781e-19 2.184000000000000000e+03 2.002374255887515778e-19 2.186000000000000000e+03 2.002654243947876840e-19 2.188000000000000000e+03 2.000869374822106382e-19 2.190000000000000000e+03 1.996829751942851123e-19 2.192000000000000000e+03 2.006267942607513895e-19 2.194000000000000000e+03 2.013086924671915926e-19 2.196000000000000000e+03 2.011297405620953342e-19 2.198000000000000000e+03 2.016624528332931265e-19 2.200000000000000000e+03 2.010372838942692693e-19 2.202000000000000000e+03 2.020859138495374276e-19 2.204000000000000000e+03 2.013928636668859270e-19 2.206000000000000000e+03 2.020515075977831873e-19 2.208000000000000000e+03 2.021847199640732003e-19 2.210000000000000000e+03 2.024975349605458698e-19 2.212000000000000000e+03 2.031446260211945766e-19 2.214000000000000000e+03 2.029443106890321650e-19 2.216000000000000000e+03 2.026920958000547774e-19 2.218000000000000000e+03 2.031779317229643515e-19 2.220000000000000000e+03 2.030284368112927303e-19 2.222000000000000000e+03 2.034029220520298249e-19 2.224000000000000000e+03 2.033528719484584005e-19 2.226000000000000000e+03 2.040674605078627005e-19 2.228000000000000000e+03 2.053665142300032548e-19 2.230000000000000000e+03 2.045904974087670845e-19 2.232000000000000000e+03 2.049535333580619858e-19 2.234000000000000000e+03 2.043892667091441843e-19 2.236000000000000000e+03 2.043605503786880807e-19 2.238000000000000000e+03 2.045822507164636358e-19 2.240000000000000000e+03 2.044546188216927198e-19 2.242000000000000000e+03 2.053690795371636795e-19 2.244000000000000000e+03 2.054081019087340426e-19 2.246000000000000000e+03 2.054145601350748584e-19 2.248000000000000000e+03 2.060761974549191417e-19 2.250000000000000000e+03 2.058552113260305273e-19 2.252000000000000000e+03 2.061818526588549492e-19 2.254000000000000000e+03 2.060805660609541500e-19 2.256000000000000000e+03 2.066493217131308488e-19 2.258000000000000000e+03 2.065137935183671402e-19 2.260000000000000000e+03 2.076622503928503217e-19 2.262000000000000000e+03 2.075094034476344049e-19 2.264000000000000000e+03 2.076459563231452531e-19 2.266000000000000000e+03 2.074524349107305425e-19 2.268000000000000000e+03 2.070008474131418494e-19 2.270000000000000000e+03 2.068179957357791824e-19 2.272000000000000000e+03 2.082215500259381765e-19 2.274000000000000000e+03 2.085732499546926691e-19 2.276000000000000000e+03 2.084488591515981829e-19 2.278000000000000000e+03 2.091418282237401442e-19 2.280000000000000000e+03 2.091424905459984714e-19 2.282000000000000000e+03 2.089414464651042188e-19 2.284000000000000000e+03 2.086480681233198278e-19 2.286000000000000000e+03 2.085343578429562827e-19 2.288000000000000000e+03 2.084610120884860800e-19 2.290000000000000000e+03 2.087481286289291856e-19 2.292000000000000000e+03 2.090434502569594389e-19 2.294000000000000000e+03 2.096504429811789568e-19 2.296000000000000000e+03 2.099901570835303033e-19 2.298000000000000000e+03 2.097165221927187690e-19 2.300000000000000000e+03 2.097207766832633656e-19 2.302000000000000000e+03 2.100550293794375232e-19 2.304000000000000000e+03 2.106760172697538002e-19 2.306000000000000000e+03 2.110378737926776084e-19 2.308000000000000000e+03 2.107851036068268562e-19 2.310000000000000000e+03 2.118559486295637395e-19 2.312000000000000000e+03 2.110444150494594787e-19 2.314000000000000000e+03 2.120365214958069497e-19 2.316000000000000000e+03 2.123969906189427125e-19 2.318000000000000000e+03 2.118496535113093012e-19 2.320000000000000000e+03 2.125028271561298782e-19 2.322000000000000000e+03 2.128784895327412109e-19 2.324000000000000000e+03 2.130958668325040985e-19 2.326000000000000000e+03 2.126662218870328222e-19 2.328000000000000000e+03 2.132298396117622202e-19 2.330000000000000000e+03 2.131516727442441902e-19 2.332000000000000000e+03 2.129823127197687663e-19 2.334000000000000000e+03 2.136125770014249043e-19 2.336000000000000000e+03 2.137745924042383724e-19 2.338000000000000000e+03 2.138665036227984068e-19 2.340000000000000000e+03 2.145901337444915775e-19 2.342000000000000000e+03 2.146187470429744137e-19 2.344000000000000000e+03 2.136608096693466339e-19 2.346000000000000000e+03 2.142900664260109850e-19 2.348000000000000000e+03 2.146970566080576661e-19 2.350000000000000000e+03 2.156352121125069648e-19 2.352000000000000000e+03 2.159389829897006711e-19 2.354000000000000000e+03 2.157515053849245861e-19 2.356000000000000000e+03 2.152675465597592366e-19 2.358000000000000000e+03 2.158187238432976233e-19 2.360000000000000000e+03 2.155313400773137689e-19 2.362000000000000000e+03 2.161570754617227336e-19 2.364000000000000000e+03 2.164046076537092107e-19 2.366000000000000000e+03 2.169620271863823129e-19 2.368000000000000000e+03 2.173584503624876710e-19 2.370000000000000000e+03 2.175373870380108177e-19 2.372000000000000000e+03 2.282441912044101775e-19 2.374000000000000000e+03 2.367510508801621848e-19 2.376000000000000000e+03 2.199913518869476293e-19 2.378000000000000000e+03 2.179627144777957086e-19 2.380000000000000000e+03 2.179744092553763061e-19 2.382000000000000000e+03 2.396446543896490014e-19 2.384000000000000000e+03 3.190738307868252666e-19 2.386000000000000000e+03 2.486763409486700081e-19 2.388000000000000000e+03 2.211602884634813993e-19 2.390000000000000000e+03 4.053773626652159410e-19 2.392000000000000000e+03 5.427425398448379306e-19 2.394000000000000000e+03 3.438543938441554086e-19 2.396000000000000000e+03 3.526132610084251727e-19 2.398000000000000000e+03 4.569488555721195491e-19 2.400000000000000000e+03 4.882170704086260898e-19 2.402000000000000000e+03 5.309375625111493621e-19 2.404000000000000000e+03 3.010238557753780543e-19 2.406000000000000000e+03 2.244695669563166324e-19 2.408000000000000000e+03 3.250544854178772535e-19 2.410000000000000000e+03 4.272980294919608597e-19 2.412000000000000000e+03 7.271014690273181884e-19 2.414000000000000000e+03 7.348645145396769906e-19 2.416000000000000000e+03 1.005845689378210997e-18 2.418000000000000000e+03 4.328627786457677776e-19 2.420000000000000000e+03 5.176943389407520205e-19 2.422000000000000000e+03 4.275756040554013050e-19 2.424000000000000000e+03 2.255835021037335228e-19 2.426000000000000000e+03 2.220005567406191857e-19 2.428000000000000000e+03 2.224431446064456241e-19 2.430000000000000000e+03 4.275079313792682608e-19 2.432000000000000000e+03 7.263267908163417194e-19 2.434000000000000000e+03 5.016617290540578616e-19 2.436000000000000000e+03 5.479363958654595817e-19 2.438000000000000000e+03 2.882090241951584793e-19 2.440000000000000000e+03 2.501590551189420314e-19 2.442000000000000000e+03 2.243694145422795832e-19 2.444000000000000000e+03 2.237857278835368661e-19 2.446000000000000000e+03 2.280279953307733388e-19 2.448000000000000000e+03 3.543675116065663929e-19 2.450000000000000000e+03 3.885703139529629549e-19 2.452000000000000000e+03 2.378629351624240916e-19 2.454000000000000000e+03 2.240756249605401828e-19 2.456000000000000000e+03 2.300804061285707582e-19 2.458000000000000000e+03 2.625163864318831062e-19 2.460000000000000000e+03 2.417206650167141426e-19 2.462000000000000000e+03 2.239855737605961872e-19 2.464000000000000000e+03 2.246852031568758478e-19 2.466000000000000000e+03 2.257077527711422134e-19 2.468000000000000000e+03 2.278696241072820762e-19 2.470000000000000000e+03 2.288259899188246757e-19 2.472000000000000000e+03 2.280257739332821128e-19 2.474000000000000000e+03 2.270118590967913676e-19 2.476000000000000000e+03 2.264270849663836361e-19 2.478000000000000000e+03 2.262886428547264086e-19 2.480000000000000000e+03 2.259701626200669965e-19 2.482000000000000000e+03 2.261968768156995196e-19 2.484000000000000000e+03 2.269853931464666827e-19 2.486000000000000000e+03 2.266488805081884663e-19 2.488000000000000000e+03 2.270719997272524727e-19 2.490000000000000000e+03 2.270036630098875443e-19 2.492000000000000000e+03 2.273332936737062759e-19 2.494000000000000000e+03 2.281761894737976709e-19 2.496000000000000000e+03 2.286967038890469645e-19 2.498000000000000000e+03 2.296409142251917147e-19 2.500000000000000000e+03 2.294419590989237602e-19 2.502000000000000000e+03 2.281266926938440067e-19 2.504000000000000000e+03 2.288435664045960425e-19 2.506000000000000000e+03 2.294228285197940300e-19 2.508000000000000000e+03 2.290964492100882668e-19 2.510000000000000000e+03 2.294180742136347196e-19 2.512000000000000000e+03 2.299701757832733870e-19 2.514000000000000000e+03 2.303085939840615236e-19 2.516000000000000000e+03 2.299989562110193207e-19 2.518000000000000000e+03 2.302525199610895092e-19 2.520000000000000000e+03 2.300508980662301673e-19 2.522000000000000000e+03 2.300845295557125071e-19 2.524000000000000000e+03 2.297797231446368326e-19 2.526000000000000000e+03 2.299210850791673093e-19 2.528000000000000000e+03 2.312685144628812186e-19 2.530000000000000000e+03 2.308246000757914729e-19 2.532000000000000000e+03 2.305241525084612302e-19 2.534000000000000000e+03 2.313321614181655229e-19 2.536000000000000000e+03 2.323015198722278504e-19 2.538000000000000000e+03 2.322725807812139651e-19 2.540000000000000000e+03 2.332463525498798448e-19 2.542000000000000000e+03 2.334664038364610233e-19 2.544000000000000000e+03 2.332983411878352298e-19 2.546000000000000000e+03 2.364507805935122132e-19 2.548000000000000000e+03 2.459974931749502243e-19 2.550000000000000000e+03 2.566701434550863205e-19 2.552000000000000000e+03 2.582234212350163705e-19 2.554000000000000000e+03 2.513541494087096371e-19 2.556000000000000000e+03 2.385618679892176384e-19 2.558000000000000000e+03 2.360260379447551617e-19 2.560000000000000000e+03 2.355513148833516481e-19 2.562000000000000000e+03 2.354377593999305060e-19 2.564000000000000000e+03 2.349199368120592591e-19 2.566000000000000000e+03 2.347914676663722134e-19 2.568000000000000000e+03 2.341430905920833631e-19 2.570000000000000000e+03 2.346207639833879531e-19 2.572000000000000000e+03 2.350017925568520718e-19 2.574000000000000000e+03 2.346751709489192855e-19 2.576000000000000000e+03 2.350686568101126640e-19 2.578000000000000000e+03 2.349642749481255900e-19 2.580000000000000000e+03 2.346992235551173432e-19 2.582000000000000000e+03 2.345608448987906711e-19 2.584000000000000000e+03 2.358471518761814364e-19 2.586000000000000000e+03 2.348592033715897681e-19 2.588000000000000000e+03 2.358323831210767564e-19 2.590000000000000000e+03 2.355805427540559290e-19 2.592000000000000000e+03 2.360804689588076789e-19 2.594000000000000000e+03 2.364548874235461507e-19 2.596000000000000000e+03 2.362554543028009216e-19 2.598000000000000000e+03 2.361373940356883284e-19 2.600000000000000000e+03 2.364372416238348637e-19 2.602000000000000000e+03 2.368865345279306422e-19 2.604000000000000000e+03 2.368310004682135487e-19 2.606000000000000000e+03 2.380868978649951160e-19 2.608000000000000000e+03 2.389294915184138065e-19 2.610000000000000000e+03 2.386421142826895461e-19 2.612000000000000000e+03 2.379190259095855381e-19 2.614000000000000000e+03 2.374378923882625790e-19 2.616000000000000000e+03 2.375553476329818866e-19 2.618000000000000000e+03 2.381780551312343312e-19 2.620000000000000000e+03 2.380855719964156002e-19 2.622000000000000000e+03 2.377782587237705406e-19 2.624000000000000000e+03 2.383695845666066712e-19 2.626000000000000000e+03 2.388443640061199069e-19 2.628000000000000000e+03 2.394365409156790882e-19 2.630000000000000000e+03 2.393524852447767978e-19 2.632000000000000000e+03 2.401974046148634693e-19 2.634000000000000000e+03 2.394894921607830387e-19 2.636000000000000000e+03 2.399001912731423415e-19 2.638000000000000000e+03 2.411593000989721327e-19 2.640000000000000000e+03 2.406765309933536049e-19 2.642000000000000000e+03 2.410315025624030765e-19 2.644000000000000000e+03 2.409930575647198492e-19 2.646000000000000000e+03 2.412277241160451863e-19 2.648000000000000000e+03 2.410575648361585847e-19 2.650000000000000000e+03 2.408627288061465279e-19 2.652000000000000000e+03 2.416691852256006725e-19 2.654000000000000000e+03 2.414024106936387479e-19 2.656000000000000000e+03 2.420261574266127937e-19 2.658000000000000000e+03 2.423026387803546409e-19 2.660000000000000000e+03 2.414490338391364537e-19 2.662000000000000000e+03 2.412433116998222893e-19 2.664000000000000000e+03 2.412023173057789056e-19 2.666000000000000000e+03 2.434475384070600611e-19 2.668000000000000000e+03 2.439797173026213183e-19 2.670000000000000000e+03 2.441801011521747214e-19 2.672000000000000000e+03 2.449133164250065095e-19 2.674000000000000000e+03 2.469000475172122339e-19 2.676000000000000000e+03 2.462570980296269783e-19 2.678000000000000000e+03 2.450918969243595263e-19 2.680000000000000000e+03 2.444499896971175626e-19 2.682000000000000000e+03 2.431121507519138084e-19 2.684000000000000000e+03 2.443588869507346773e-19 2.686000000000000000e+03 2.450129305755889844e-19 2.688000000000000000e+03 2.447221487419240376e-19 2.690000000000000000e+03 2.447960130387523923e-19 2.692000000000000000e+03 2.447404661826596658e-19 2.694000000000000000e+03 2.447284739981680571e-19 2.696000000000000000e+03 2.456094310706161459e-19 2.698000000000000000e+03 2.460004230343796297e-19 2.700000000000000000e+03 2.462411087078827806e-19 2.702000000000000000e+03 2.471226914990552639e-19 2.704000000000000000e+03 2.475641871410751170e-19 2.706000000000000000e+03 2.504210734773716382e-19 2.708000000000000000e+03 2.528929839766357394e-19 2.710000000000000000e+03 2.501714349502501335e-19 2.712000000000000000e+03 2.482723399774150284e-19 2.714000000000000000e+03 2.488007621332894577e-19 2.716000000000000000e+03 2.477901654007402620e-19 2.718000000000000000e+03 2.481271504845027381e-19 2.720000000000000000e+03 2.481398480156389112e-19 2.722000000000000000e+03 2.481619296901614372e-19 2.724000000000000000e+03 2.472058818675147415e-19 2.726000000000000000e+03 2.473486457666058604e-19 2.728000000000000000e+03 2.482950340858299411e-19 2.730000000000000000e+03 2.493705726755295966e-19 2.732000000000000000e+03 2.493576578590272381e-19 2.734000000000000000e+03 2.485846958659371468e-19 2.736000000000000000e+03 2.491063486021565781e-19 2.738000000000000000e+03 2.495139993634968645e-19 2.740000000000000000e+03 2.481962516607102354e-19 2.742000000000000000e+03 2.503091909775421356e-19 2.744000000000000000e+03 2.499130925424755102e-19 2.746000000000000000e+03 2.495495252959623864e-19 2.748000000000000000e+03 2.498516260285998843e-19 2.750000000000000000e+03 2.501447581001735980e-19 2.752000000000000000e+03 2.500106118675973375e-19 2.754000000000000000e+03 2.502341571300859565e-19 2.756000000000000000e+03 2.509934899358968811e-19 2.758000000000000000e+03 2.508990516391722850e-19 2.760000000000000000e+03 2.520631322605780166e-19 2.762000000000000000e+03 2.516859171234896423e-19 2.764000000000000000e+03 2.514777593533140197e-19 2.766000000000000000e+03 2.521011661488370030e-19 2.768000000000000000e+03 2.515375945983603553e-19 2.770000000000000000e+03 2.521494856118712865e-19 2.772000000000000000e+03 2.523804250963321897e-19 2.774000000000000000e+03 2.518767499542957286e-19 2.776000000000000000e+03 2.527259053028355286e-19 2.778000000000000000e+03 2.517024176394016748e-19 2.780000000000000000e+03 2.527619037475631753e-19 2.782000000000000000e+03 2.537123654556577777e-19 2.784000000000000000e+03 2.540797944831357245e-19 2.786000000000000000e+03 2.535725846554631596e-19 2.788000000000000000e+03 2.533537975445254558e-19 2.790000000000000000e+03 2.545519152043218179e-19 2.792000000000000000e+03 2.556493404374029474e-19 2.794000000000000000e+03 2.565675707908139937e-19 2.796000000000000000e+03 2.567231540791192209e-19 2.798000000000000000e+03 2.567413920030546740e-19 2.800000000000000000e+03 2.584383140966278799e-19 2.802000000000000000e+03 2.591364191381499269e-19 2.804000000000000000e+03 2.585943275379590901e-19 2.806000000000000000e+03 2.583798264223627196e-19 2.808000000000000000e+03 2.597390747841605047e-19 2.810000000000000000e+03 2.593891916625815048e-19 2.812000000000000000e+03 2.582952796392723215e-19 2.814000000000000000e+03 2.575731579471001345e-19 2.816000000000000000e+03 2.563945437123911289e-19 2.818000000000000000e+03 2.566086164388488190e-19 2.820000000000000000e+03 2.568115788571076096e-19 2.822000000000000000e+03 2.557354573596284663e-19 2.824000000000000000e+03 2.573049465806180040e-19 2.826000000000000000e+03 2.572919522655421824e-19 2.828000000000000000e+03 2.575610510231450029e-19 2.830000000000000000e+03 2.566708907209023865e-19 2.832000000000000000e+03 2.566992294565591573e-19 2.834000000000000000e+03 2.572483623057587838e-19 2.836000000000000000e+03 2.582053797761328574e-19 2.838000000000000000e+03 2.582719976477419177e-19 2.840000000000000000e+03 2.597588771539632809e-19 2.842000000000000000e+03 2.776303781869583550e-19 2.844000000000000000e+03 2.809785181950672331e-19 2.846000000000000000e+03 2.620245757234376751e-19 2.848000000000000000e+03 2.659896183019761682e-19 2.850000000000000000e+03 2.695749348213452296e-19 2.852000000000000000e+03 2.601414266465255188e-19 2.854000000000000000e+03 2.655431023236613761e-19 2.856000000000000000e+03 3.135298797789500941e-19 2.858000000000000000e+03 5.752317283626396191e-19 2.860000000000000000e+03 5.234916748499542722e-19 2.862000000000000000e+03 3.761674192648946231e-19 2.864000000000000000e+03 2.814457727844692841e-19 2.866000000000000000e+03 2.796130860531108228e-19 2.868000000000000000e+03 3.052926573971134360e-19 2.870000000000000000e+03 2.909817190053385883e-19 2.872000000000000000e+03 2.639415888776474298e-19 2.874000000000000000e+03 2.703861683832645585e-19 2.876000000000000000e+03 3.180092823836608727e-19 2.878000000000000000e+03 2.850566325217074265e-19 2.880000000000000000e+03 2.631268987337108865e-19 2.882000000000000000e+03 2.753691346604142830e-19 2.884000000000000000e+03 2.984073520544005852e-19 2.886000000000000000e+03 2.708351129732478595e-19 2.888000000000000000e+03 2.674093393361446837e-19 2.890000000000000000e+03 2.859226225253029306e-19 2.892000000000000000e+03 2.991690538910242956e-19 2.894000000000000000e+03 2.993554068880974520e-19 2.896000000000000000e+03 2.790633094614322766e-19 2.898000000000000000e+03 2.641945353486716925e-19 2.900000000000000000e+03 2.641848545798303701e-19 2.902000000000000000e+03 2.644520224377839303e-19 2.904000000000000000e+03 2.647937723357298121e-19 2.906000000000000000e+03 2.654591375384605117e-19 2.908000000000000000e+03 2.647092732601665930e-19 2.910000000000000000e+03 2.643184969269181306e-19 2.912000000000000000e+03 2.653447094768395498e-19 2.914000000000000000e+03 2.645948528084821055e-19 2.916000000000000000e+03 2.649119525114695915e-19 2.918000000000000000e+03 2.659896904026745103e-19 2.920000000000000000e+03 2.658534704792607736e-19 2.922000000000000000e+03 2.647675836141676515e-19 2.924000000000000000e+03 2.655672512689727643e-19 2.926000000000000000e+03 2.657895500889002050e-19 2.928000000000000000e+03 2.655359579525951737e-19 2.930000000000000000e+03 2.655733705975003739e-19 2.932000000000000000e+03 2.669437739529871357e-19 2.934000000000000000e+03 2.674559366090076654e-19 2.936000000000000000e+03 2.663778735105750003e-19 2.938000000000000000e+03 2.679071616822674641e-19 2.940000000000000000e+03 2.679129913787696959e-19 2.942000000000000000e+03 2.671454435830419032e-19 2.944000000000000000e+03 2.674680417753410742e-19 2.946000000000000000e+03 2.674214834463956418e-19 2.948000000000000000e+03 2.684875141766881734e-19 2.950000000000000000e+03 2.685811028133210129e-19 2.952000000000000000e+03 2.681123729079246234e-19 2.954000000000000000e+03 2.686193334268275785e-19 2.956000000000000000e+03 2.672676317783378144e-19 2.958000000000000000e+03 2.689652720181599431e-19 2.960000000000000000e+03 2.679862863630300700e-19 2.962000000000000000e+03 2.681449058678428986e-19 2.964000000000000000e+03 2.690069913139325226e-19 2.966000000000000000e+03 2.704899191459613706e-19 2.968000000000000000e+03 2.710327165698191894e-19 2.970000000000000000e+03 2.705719125938301977e-19 2.972000000000000000e+03 2.702641252792939365e-19 2.974000000000000000e+03 2.701579189500527073e-19 2.976000000000000000e+03 2.705520079216401115e-19 2.978000000000000000e+03 2.711301688551123081e-19 2.980000000000000000e+03 2.713192170195587913e-19 2.982000000000000000e+03 2.715640360212473720e-19 2.984000000000000000e+03 2.715045944970181329e-19 2.986000000000000000e+03 2.709570875678246734e-19 2.988000000000000000e+03 2.716630975479771615e-19 2.990000000000000000e+03 2.730291054070447451e-19 2.992000000000000000e+03 2.736675017185449047e-19 2.994000000000000000e+03 2.719185092883129157e-19 2.996000000000000000e+03 2.719534390720873893e-19 2.998000000000000000e+03 2.733844446505739341e-19 3.000000000000000000e+03 2.738501703546331813e-19 3.002000000000000000e+03 2.737685896997909561e-19 3.004000000000000000e+03 2.728691514732720987e-19 3.006000000000000000e+03 2.734286622127149759e-19 3.008000000000000000e+03 2.737032025947181438e-19 3.010000000000000000e+03 2.742327131689514368e-19 3.012000000000000000e+03 2.756645046915023684e-19 3.014000000000000000e+03 2.769049928650644495e-19 3.016000000000000000e+03 2.762167028884860566e-19 3.018000000000000000e+03 2.760305147238600460e-19 3.020000000000000000e+03 2.759521198512369287e-19 3.022000000000000000e+03 2.761609742818957735e-19 3.024000000000000000e+03 2.761124256547923567e-19 3.026000000000000000e+03 2.757416027706108425e-19 3.028000000000000000e+03 2.763808837861695633e-19 3.030000000000000000e+03 2.762997584622282214e-19 3.032000000000000000e+03 2.765558848740680038e-19 3.034000000000000000e+03 2.760877562211630563e-19 3.036000000000000000e+03 2.769868404021679850e-19 3.038000000000000000e+03 2.767286874171124968e-19 3.040000000000000000e+03 2.765878623668844686e-19 3.042000000000000000e+03 2.760881375648805279e-19 3.044000000000000000e+03 2.769317999659153872e-19 3.046000000000000000e+03 2.774782301566618124e-19 3.048000000000000000e+03 2.772693517983937351e-19 3.050000000000000000e+03 2.778346845679656409e-19 3.052000000000000000e+03 2.781691702725040808e-19 3.054000000000000000e+03 2.781209975956220561e-19 3.056000000000000000e+03 2.783024770113067264e-19 3.058000000000000000e+03 2.780158543598870614e-19 3.060000000000000000e+03 2.782678154987675464e-19 3.062000000000000000e+03 2.790562191222205489e-19 3.064000000000000000e+03 2.856132766148657632e-19 3.066000000000000000e+03 2.820062270405239277e-19 3.068000000000000000e+03 2.790979238495899610e-19 3.070000000000000000e+03 2.784030636514871238e-19 3.072000000000000000e+03 2.795564654778472469e-19 3.074000000000000000e+03 2.800675996107713994e-19 3.076000000000000000e+03 2.800623083597371697e-19 3.078000000000000000e+03 2.801218417174878717e-19 3.080000000000000000e+03 2.798123506395909007e-19 3.082000000000000000e+03 2.803857313870889553e-19 3.084000000000000000e+03 2.810724579154485881e-19 3.086000000000000000e+03 2.811517213141617223e-19 3.088000000000000000e+03 2.801080528807280253e-19 3.090000000000000000e+03 2.799527890500122699e-19 3.092000000000000000e+03 2.815823265476503197e-19 3.094000000000000000e+03 2.816532400898773045e-19 3.096000000000000000e+03 2.808706866298751012e-19 3.098000000000000000e+03 2.813064161187031280e-19 3.100000000000000000e+03 2.831895703941928090e-19 3.102000000000000000e+03 2.828817160348954364e-19 3.104000000000000000e+03 2.833102044335007040e-19 3.106000000000000000e+03 2.833161189320921165e-19 3.108000000000000000e+03 2.832422720653925595e-19 3.110000000000000000e+03 2.831925855453885686e-19 3.112000000000000000e+03 2.833552907667377850e-19 3.114000000000000000e+03 2.833805523661074159e-19 3.116000000000000000e+03 2.844526080257363409e-19 3.118000000000000000e+03 2.834833093127848265e-19 3.120000000000000000e+03 2.842123931137968768e-19 3.122000000000000000e+03 2.845494090444336964e-19 3.124000000000000000e+03 2.834511237181096971e-19 3.126000000000000000e+03 2.837889809319388133e-19 3.128000000000000000e+03 2.845157631354412073e-19 3.130000000000000000e+03 2.855696320364543804e-19 3.132000000000000000e+03 2.848721178270834184e-19 3.134000000000000000e+03 2.852465022389659350e-19 3.136000000000000000e+03 2.863404829064268225e-19 3.138000000000000000e+03 2.851960136800674123e-19 3.140000000000000000e+03 2.864358130902217597e-19 3.142000000000000000e+03 2.862537209857090670e-19 3.144000000000000000e+03 2.864680879255852828e-19 3.146000000000000000e+03 2.866633532547037815e-19 3.148000000000000000e+03 2.866715818975917589e-19 3.150000000000000000e+03 2.873926159079767967e-19 3.152000000000000000e+03 2.879891716782194494e-19 3.154000000000000000e+03 2.884664935082583349e-19 3.156000000000000000e+03 2.877365461008169105e-19 3.158000000000000000e+03 2.863690372901018031e-19 3.160000000000000000e+03 2.880616008728040829e-19 3.162000000000000000e+03 2.888758939597535798e-19 3.164000000000000000e+03 2.890142533789689172e-19 3.166000000000000000e+03 2.884990491536304101e-19 3.168000000000000000e+03 2.888292250946969355e-19 3.170000000000000000e+03 2.899166190913614424e-19 3.172000000000000000e+03 2.906136205315354499e-19 3.174000000000000000e+03 2.893352623186605094e-19 3.176000000000000000e+03 2.897255620748854658e-19 3.178000000000000000e+03 2.905796188044955560e-19 3.180000000000000000e+03 2.897230116414431863e-19 3.182000000000000000e+03 2.900125116637550688e-19 3.184000000000000000e+03 2.911316922390117082e-19 3.186000000000000000e+03 2.909245505980016065e-19 3.188000000000000000e+03 2.905181641664075497e-19 3.190000000000000000e+03 2.906924737629299052e-19 3.192000000000000000e+03 2.901777423807819727e-19 3.194000000000000000e+03 2.911748391005660989e-19 3.196000000000000000e+03 2.916031998499830481e-19 3.198000000000000000e+03 2.917927464749318898e-19 3.200000000000000000e+03 2.907909909585619159e-19 3.202000000000000000e+03 2.919390397316677142e-19 3.204000000000000000e+03 2.925511264162028917e-19 3.206000000000000000e+03 2.922615811629071790e-19 3.208000000000000000e+03 2.925459260707933999e-19 3.210000000000000000e+03 2.935174993943974403e-19 3.212000000000000000e+03 2.935689903074634053e-19 3.214000000000000000e+03 2.938418448637602459e-19 3.216000000000000000e+03 2.931714558689285857e-19 3.218000000000000000e+03 2.940666891913757293e-19 3.220000000000000000e+03 2.936333449568614831e-19 3.222000000000000000e+03 2.939755592731443166e-19 3.224000000000000000e+03 2.933822702999094502e-19 3.226000000000000000e+03 2.944620540644519632e-19 3.228000000000000000e+03 2.946332748028528619e-19 3.230000000000000000e+03 2.944017122888694975e-19 3.232000000000000000e+03 2.946761371474211770e-19 3.234000000000000000e+03 2.949002724876967997e-19 3.236000000000000000e+03 2.954035585047463238e-19 3.238000000000000000e+03 2.953935430631876387e-19 3.240000000000000000e+03 2.947737272102622655e-19 3.242000000000000000e+03 2.953302819915823379e-19 3.244000000000000000e+03 2.963131588554876278e-19 3.246000000000000000e+03 2.956650013108435678e-19 3.248000000000000000e+03 2.964387387463590342e-19 3.250000000000000000e+03 2.957729333755570998e-19 3.252000000000000000e+03 2.969345925310574617e-19 3.254000000000000000e+03 2.972227723046779136e-19 3.256000000000000000e+03 2.979445622842248066e-19 3.258000000000000000e+03 2.979842677390728611e-19 3.260000000000000000e+03 2.972759605127960700e-19 3.262000000000000000e+03 2.985663532046414853e-19 3.264000000000000000e+03 2.986738750181029152e-19 3.266000000000000000e+03 2.987907381780431241e-19 3.268000000000000000e+03 3.048249771153964095e-19 3.270000000000000000e+03 3.043904259172222950e-19 3.272000000000000000e+03 2.993415019277445836e-19 3.274000000000000000e+03 2.991742622620998144e-19 3.276000000000000000e+03 2.986668036803173267e-19 3.278000000000000000e+03 2.991912375672426856e-19 3.280000000000000000e+03 3.084160252005492785e-19 3.282000000000000000e+03 3.425351284546602381e-19 3.284000000000000000e+03 3.711366797226973188e-19 3.286000000000000000e+03 3.176652103313360611e-19 3.288000000000000000e+03 3.024925126348404070e-19 3.290000000000000000e+03 3.177624641645102863e-19 3.292000000000000000e+03 3.165411259212365820e-19 3.294000000000000000e+03 3.044966501471064443e-19 3.296000000000000000e+03 3.558559820155344225e-19 3.298000000000000000e+03 4.089278205298736029e-19 3.300000000000000000e+03 3.312321371663567934e-19 3.302000000000000000e+03 3.047212983387018298e-19 3.304000000000000000e+03 3.020673294572274717e-19 3.306000000000000000e+03 3.024328466379551825e-19 3.308000000000000000e+03 3.016532126239046457e-19 3.310000000000000000e+03 3.028926374131072744e-19 3.312000000000000000e+03 3.030517538835445759e-19 3.314000000000000000e+03 3.032175823473920218e-19 3.316000000000000000e+03 3.027534764215772380e-19 3.318000000000000000e+03 3.039691011829688853e-19 3.320000000000000000e+03 3.154423857688401638e-19 3.322000000000000000e+03 3.168094949235975539e-19 3.324000000000000000e+03 3.053962073360826359e-19 3.326000000000000000e+03 3.048734506687246512e-19 3.328000000000000000e+03 3.133334652174195095e-19 3.330000000000000000e+03 3.076771167581697671e-19 3.332000000000000000e+03 3.053184031964728783e-19 3.334000000000000000e+03 3.099127001655517874e-19 3.336000000000000000e+03 3.282695296302738159e-19 3.338000000000000000e+03 3.250130309937843410e-19 3.340000000000000000e+03 3.377222792070645596e-19 3.342000000000000000e+03 3.143681319923318101e-19 3.344000000000000000e+03 3.059064037082385465e-19 3.346000000000000000e+03 3.106003871140930597e-19 3.348000000000000000e+03 3.384694932579874969e-19 3.350000000000000000e+03 3.224436488288048838e-19 3.352000000000000000e+03 3.061580779343790942e-19 3.354000000000000000e+03 3.061500557894798610e-19 3.356000000000000000e+03 3.069384639870379555e-19 3.358000000000000000e+03 3.069161472813515731e-19 3.360000000000000000e+03 3.170978742953593459e-19 3.362000000000000000e+03 3.352979070561851946e-19 3.364000000000000000e+03 3.156303005532512631e-19 3.366000000000000000e+03 3.269524811726354167e-19 3.368000000000000000e+03 3.169364309037413169e-19 3.370000000000000000e+03 3.162604910160521684e-19 3.372000000000000000e+03 3.093388031693434258e-19 3.374000000000000000e+03 3.289184784961008599e-19 3.376000000000000000e+03 3.735314234598378051e-19 3.378000000000000000e+03 3.241487258935414581e-19 3.380000000000000000e+03 3.093105907168206638e-19 3.382000000000000000e+03 3.109031089507330568e-19 3.384000000000000000e+03 3.099637890567109986e-19 3.386000000000000000e+03 3.110311254093636726e-19 3.388000000000000000e+03 3.263422214246329911e-19 3.390000000000000000e+03 3.206302576087378399e-19 3.392000000000000000e+03 3.261560008666085805e-19 3.394000000000000000e+03 3.854127990705494225e-19 3.396000000000000000e+03 3.488908998780919678e-19 3.398000000000000000e+03 3.130926503848056563e-19 3.400000000000000000e+03 3.112662876627010238e-19 3.402000000000000000e+03 3.105717215703684469e-19 3.404000000000000000e+03 3.116169009755492339e-19 3.406000000000000000e+03 3.112111582136204633e-19 3.408000000000000000e+03 3.105210464766840408e-19 3.410000000000000000e+03 3.122911433555860585e-19 3.412000000000000000e+03 3.123512363506598796e-19 3.414000000000000000e+03 3.132365558441403420e-19 3.416000000000000000e+03 3.132586002137598978e-19 3.418000000000000000e+03 3.125889578755531140e-19 3.420000000000000000e+03 3.130262862816997074e-19 3.422000000000000000e+03 3.133520523849742423e-19 3.424000000000000000e+03 3.130683136723852580e-19 3.426000000000000000e+03 3.140006814818934242e-19 3.428000000000000000e+03 3.137598628023506407e-19 3.430000000000000000e+03 3.146127166646942949e-19 3.432000000000000000e+03 3.144079398005504883e-19 3.434000000000000000e+03 3.146813059002384554e-19 3.436000000000000000e+03 3.144552386014660336e-19 3.438000000000000000e+03 3.148020380672037979e-19 3.440000000000000000e+03 3.155450894117804152e-19 3.442000000000000000e+03 3.146395395840537342e-19 3.444000000000000000e+03 3.146841835111361625e-19 3.446000000000000000e+03 3.152326631447410999e-19 3.448000000000000000e+03 3.156040792395020394e-19 3.450000000000000000e+03 3.157998545031588336e-19 3.452000000000000000e+03 3.168917669681761150e-19 3.454000000000000000e+03 3.165806859925669821e-19 3.456000000000000000e+03 3.172420589739518572e-19 3.458000000000000000e+03 3.168560620013867519e-19 3.460000000000000000e+03 3.166088144898514118e-19 3.462000000000000000e+03 3.172508587889965026e-19 3.464000000000000000e+03 3.167881746164901540e-19 3.466000000000000000e+03 3.174871128929093234e-19 3.468000000000000000e+03 3.173883336850462490e-19 3.470000000000000000e+03 3.170817214120297578e-19 3.472000000000000000e+03 3.177920577410309881e-19 3.474000000000000000e+03 3.184961660023084722e-19 3.476000000000000000e+03 3.182111312119182083e-19 3.478000000000000000e+03 3.182083810455870927e-19 3.480000000000000000e+03 3.182998102821173418e-19 3.482000000000000000e+03 3.185603708402854790e-19 3.484000000000000000e+03 3.193059046487260533e-19 3.486000000000000000e+03 3.196896802379772806e-19 3.488000000000000000e+03 3.196489915716280658e-19 3.490000000000000000e+03 3.192166811231779151e-19 3.492000000000000000e+03 3.204429237915413351e-19 3.494000000000000000e+03 3.197540066702464093e-19 3.496000000000000000e+03 3.195256427630207557e-19 3.498000000000000000e+03 3.203255710609633126e-19 3.500000000000000000e+03 3.207086473205689744e-19 3.502000000000000000e+03 3.208442909980276899e-19 3.504000000000000000e+03 3.208196456784455369e-19 3.506000000000000000e+03 3.200792077858910617e-19 3.508000000000000000e+03 3.216886602814516440e-19 3.510000000000000000e+03 3.233023582286685132e-19 3.512000000000000000e+03 3.223289216831446595e-19 3.514000000000000000e+03 3.212790110004053448e-19 3.516000000000000000e+03 3.220136147444052249e-19 3.518000000000000000e+03 3.228172828932723935e-19 3.520000000000000000e+03 3.233099794439977088e-19 3.522000000000000000e+03 3.227845873109418688e-19 3.524000000000000000e+03 3.237865974452021560e-19 3.526000000000000000e+03 3.228362684800330891e-19 3.528000000000000000e+03 3.247854433309544840e-19 3.530000000000000000e+03 3.221034080901330176e-19 3.532000000000000000e+03 3.232934629972927145e-19 3.534000000000000000e+03 3.231904665886691506e-19 3.536000000000000000e+03 3.231265143713451972e-19 3.538000000000000000e+03 3.234204020347627788e-19 3.540000000000000000e+03 3.238557723799009212e-19 3.542000000000000000e+03 3.248380851075950013e-19 3.544000000000000000e+03 3.244625710292104898e-19 3.546000000000000000e+03 3.250098286918510610e-19 3.548000000000000000e+03 3.258210053831828069e-19 3.550000000000000000e+03 3.257390840755381822e-19 3.552000000000000000e+03 3.254303375630472021e-19 3.554000000000000000e+03 3.253659065500752468e-19 3.556000000000000000e+03 3.246246578735156968e-19 3.558000000000000000e+03 3.255196954009485725e-19 3.560000000000000000e+03 3.267735339464161634e-19 3.562000000000000000e+03 3.268606964094130226e-19 3.564000000000000000e+03 3.266230401475085449e-19 3.566000000000000000e+03 3.253692525633614368e-19 3.568000000000000000e+03 3.258992183320041394e-19 3.570000000000000000e+03 3.274988976273054111e-19 3.572000000000000000e+03 3.283164777169653648e-19 3.574000000000000000e+03 3.317537953343747655e-19 3.576000000000000000e+03 3.322158231935657653e-19 3.578000000000000000e+03 3.282019098258443221e-19 3.580000000000000000e+03 3.286752248100273987e-19 3.582000000000000000e+03 3.287654254995913828e-19 3.584000000000000000e+03 3.287362925441723171e-19 3.586000000000000000e+03 3.289447832042026788e-19 3.588000000000000000e+03 3.288736962884791902e-19 3.590000000000000000e+03 3.289976407813920723e-19 3.592000000000000000e+03 3.297102310319553977e-19 3.594000000000000000e+03 3.283616167487355719e-19 3.596000000000000000e+03 3.290818320796605239e-19 3.598000000000000000e+03 3.298562575772809868e-19 3.600000000000000000e+03 3.302654267124351262e-19 3.602000000000000000e+03 3.311678996630971340e-19 3.604000000000000000e+03 3.341182875135989208e-19 3.606000000000000000e+03 3.732157411994901602e-19 3.608000000000000000e+03 4.057882921961552761e-19 3.610000000000000000e+03 3.683236638667725666e-19 3.612000000000000000e+03 3.345499185589949681e-19 3.614000000000000000e+03 3.463295074927347135e-19 3.616000000000000000e+03 6.327025670341970433e-19 3.618000000000000000e+03 4.028270719410610695e-18 3.620000000000000000e+03 4.964780494580333223e-18 3.622000000000000000e+03 1.442238874815799063e-18 3.624000000000000000e+03 3.671776130587759276e-19 3.626000000000000000e+03 3.379936654755638298e-19 3.628000000000000000e+03 3.355429686671716584e-19 3.630000000000000000e+03 3.336796536440603686e-19 3.632000000000000000e+03 3.337112691875274022e-19 3.634000000000000000e+03 3.337988232595341849e-19 3.636000000000000000e+03 3.350456788727079680e-19 3.638000000000000000e+03 3.486383466081820432e-19 3.640000000000000000e+03 3.467047056473568339e-19 3.642000000000000000e+03 3.350475670249552504e-19 3.644000000000000000e+03 3.344535611784463470e-19 3.646000000000000000e+03 3.358243453178800051e-19 3.648000000000000000e+03 3.362661084750332556e-19 3.650000000000000000e+03 3.378671948268753126e-19 3.652000000000000000e+03 3.432146971029272856e-19 3.654000000000000000e+03 3.372101413202658221e-19 3.656000000000000000e+03 3.355080731289650606e-19 3.658000000000000000e+03 3.362701224637949905e-19 3.660000000000000000e+03 3.371294519107126915e-19 3.662000000000000000e+03 3.378469979406668761e-19 3.664000000000000000e+03 3.371875071102240617e-19 3.666000000000000000e+03 3.369936512948195122e-19 3.668000000000000000e+03 3.370619428398125808e-19 3.670000000000000000e+03 3.365422119711284864e-19 3.672000000000000000e+03 3.377062095565133593e-19 3.674000000000000000e+03 3.377075150634968646e-19 3.676000000000000000e+03 3.386399625357714846e-19 3.678000000000000000e+03 3.378761677821181195e-19 3.680000000000000000e+03 3.387296625865704726e-19 3.682000000000000000e+03 3.389016916825780056e-19 3.684000000000000000e+03 3.385181827887164542e-19 3.686000000000000000e+03 3.394209776017935517e-19 3.688000000000000000e+03 3.384829332219996743e-19 3.690000000000000000e+03 3.395749965285887281e-19 3.692000000000000000e+03 3.409920882727290147e-19 3.694000000000000000e+03 3.408121168767772453e-19 3.696000000000000000e+03 3.403470520979304807e-19 3.698000000000000000e+03 3.404267240726927698e-19 3.700000000000000000e+03 3.401731026812637753e-19 3.702000000000000000e+03 3.395626523889873598e-19 3.704000000000000000e+03 3.409163417073513503e-19 3.706000000000000000e+03 3.406912604028273765e-19 3.708000000000000000e+03 3.408652281222965485e-19 3.710000000000000000e+03 3.408350851447325856e-19 3.712000000000000000e+03 3.420432288233566616e-19 3.714000000000000000e+03 3.408509637349551822e-19 3.716000000000000000e+03 3.413706590931393911e-19 3.718000000000000000e+03 3.417520180688271288e-19 3.720000000000000000e+03 3.415285274310002881e-19 3.722000000000000000e+03 3.429235561320255714e-19 3.724000000000000000e+03 3.429279885312167733e-19 3.726000000000000000e+03 3.436021451520139721e-19 3.728000000000000000e+03 3.434093750578757699e-19 3.730000000000000000e+03 3.436918390755839867e-19 3.732000000000000000e+03 3.443896984855467742e-19 3.734000000000000000e+03 3.434631101097448923e-19 3.736000000000000000e+03 3.437306521224945726e-19 3.738000000000000000e+03 3.442609179818452417e-19 3.740000000000000000e+03 3.474717317866934290e-19 3.742000000000000000e+03 3.586248324042649588e-19 3.744000000000000000e+03 3.682293046026256872e-19 3.746000000000000000e+03 3.526506162428609561e-19 3.748000000000000000e+03 3.511361852286957909e-19 3.750000000000000000e+03 3.499901366744804877e-19 3.752000000000000000e+03 3.460831660975821003e-19 3.754000000000000000e+03 3.473958955726796827e-19 3.756000000000000000e+03 3.464751593901982390e-19 3.758000000000000000e+03 3.494537459821431461e-19 3.760000000000000000e+03 3.558525126415315880e-19 3.762000000000000000e+03 3.612867922493587310e-19 3.764000000000000000e+03 3.867750123023863108e-19 3.766000000000000000e+03 3.702296056383874957e-19 3.768000000000000000e+03 3.520476042368920762e-19 3.770000000000000000e+03 3.496167616976257729e-19 3.772000000000000000e+03 3.519753286650708328e-19 3.774000000000000000e+03 3.559430331297776853e-19 3.776000000000000000e+03 3.610363711207344212e-19 3.778000000000000000e+03 3.555236222984370907e-19 3.780000000000000000e+03 3.568901823454614428e-19 3.782000000000000000e+03 3.566692576144165112e-19 3.784000000000000000e+03 3.565843707849415640e-19 3.786000000000000000e+03 3.557101860514141013e-19 3.788000000000000000e+03 3.564313954654822900e-19 3.790000000000000000e+03 3.699874603871560331e-19 3.792000000000000000e+03 3.789706569224768547e-19 3.794000000000000000e+03 3.560376791880710324e-19 3.796000000000000000e+03 3.526009535631265746e-19 3.798000000000000000e+03 3.521459970386039976e-19 3.800000000000000000e+03 3.527487403755867800e-19 3.802000000000000000e+03 3.606648806780561693e-19 3.804000000000000000e+03 3.585766481105808919e-19 3.806000000000000000e+03 3.523224070844526129e-19 3.808000000000000000e+03 3.514080045954329929e-19 3.810000000000000000e+03 3.522814776122845927e-19 3.812000000000000000e+03 3.517275662910418632e-19 3.814000000000000000e+03 3.545614315706397445e-19 3.816000000000000000e+03 3.666508608628641105e-19 3.818000000000000000e+03 3.606323899357758146e-19 3.820000000000000000e+03 3.691714833573608709e-19 3.822000000000000000e+03 3.666129367825041202e-19 3.824000000000000000e+03 3.640335797303417169e-19 3.826000000000000000e+03 3.537863814629405707e-19 3.828000000000000000e+03 3.536823383243630335e-19 3.830000000000000000e+03 3.541088558675492915e-19 3.832000000000000000e+03 3.542186643283704508e-19 3.834000000000000000e+03 3.528877433243520521e-19 3.836000000000000000e+03 3.541752296746960768e-19 3.838000000000000000e+03 3.554336961083624620e-19 3.840000000000000000e+03 3.567715936915866424e-19 3.842000000000000000e+03 3.585799460380372358e-19 3.844000000000000000e+03 3.776967527420982430e-19 3.846000000000000000e+03 3.634051350677883166e-19 3.848000000000000000e+03 3.560865188626564062e-19 3.850000000000000000e+03 3.559569110578109322e-19 3.852000000000000000e+03 3.663050149580696331e-19 3.854000000000000000e+03 3.823323288906948716e-19 3.856000000000000000e+03 3.583391373993778360e-19 3.858000000000000000e+03 3.571130693975422955e-19 3.860000000000000000e+03 3.578478280285459739e-19 3.862000000000000000e+03 3.568634407900545104e-19 3.864000000000000000e+03 3.573933266061349732e-19 3.866000000000000000e+03 3.567533727272917684e-19 3.868000000000000000e+03 3.565875620192514848e-19 3.870000000000000000e+03 3.578235530882183485e-19 3.872000000000000000e+03 3.585390594960328451e-19 3.874000000000000000e+03 3.565929851620753036e-19 3.876000000000000000e+03 3.574654260773523485e-19 3.878000000000000000e+03 3.581841063686806337e-19 3.880000000000000000e+03 3.589955740460156195e-19 3.882000000000000000e+03 3.592379054663445136e-19 3.884000000000000000e+03 3.593430697766501139e-19 3.886000000000000000e+03 3.592750407800558833e-19 3.888000000000000000e+03 3.602907359437922781e-19 3.890000000000000000e+03 3.593451303833297307e-19 3.892000000000000000e+03 3.595078947253428581e-19 3.894000000000000000e+03 3.598670047204734925e-19 3.896000000000000000e+03 3.619457377020396124e-19 3.898000000000000000e+03 3.605004974103370351e-19 3.900000000000000000e+03 3.602589921793141700e-19 3.902000000000000000e+03 3.616927465346257608e-19 3.904000000000000000e+03 3.615727867088701969e-19 3.906000000000000000e+03 3.622151959014388764e-19 3.908000000000000000e+03 3.622852494874717329e-19 3.910000000000000000e+03 3.622003198760017357e-19 3.912000000000000000e+03 3.619401164066697178e-19 3.914000000000000000e+03 3.625469727310812517e-19 3.916000000000000000e+03 3.616774122772557542e-19 3.918000000000000000e+03 3.629088507608292877e-19 3.920000000000000000e+03 3.623626575933904720e-19 3.922000000000000000e+03 3.617028678879054497e-19 3.924000000000000000e+03 3.624205540366006409e-19 3.926000000000000000e+03 3.628438336765981848e-19 3.928000000000000000e+03 3.641945650674792243e-19 3.930000000000000000e+03 3.635308380632097738e-19 3.932000000000000000e+03 3.643825346689823071e-19 3.934000000000000000e+03 3.641735270737482429e-19 3.936000000000000000e+03 3.642974815713858963e-19 3.938000000000000000e+03 3.630654302545268834e-19 3.940000000000000000e+03 3.640025313838860423e-19 3.942000000000000000e+03 3.643883840815370469e-19 3.944000000000000000e+03 3.652986000940860431e-19 3.946000000000000000e+03 3.646361174843530162e-19 3.948000000000000000e+03 3.660366430619603049e-19 3.950000000000000000e+03 3.658822065229283713e-19 3.952000000000000000e+03 3.661046148507696489e-19 3.954000000000000000e+03 3.670383725701734497e-19 3.956000000000000000e+03 3.671523868034820015e-19 3.958000000000000000e+03 3.674811755769184806e-19 3.960000000000000000e+03 3.664566457780339437e-19 3.962000000000000000e+03 3.663435434976015005e-19 3.964000000000000000e+03 3.668750395201871069e-19 3.966000000000000000e+03 3.678667971745167162e-19 3.968000000000000000e+03 3.681472508577431242e-19 3.970000000000000000e+03 3.698202026491066409e-19 3.972000000000000000e+03 3.682277639239144728e-19 3.974000000000000000e+03 3.687004991436721387e-19 3.976000000000000000e+03 3.686164208891177681e-19 3.978000000000000000e+03 3.699851230923818905e-19 3.980000000000000000e+03 3.698743493759383064e-19 3.982000000000000000e+03 3.686506951268716680e-19 3.984000000000000000e+03 3.692008690465410259e-19 3.986000000000000000e+03 3.700282130314510974e-19 3.988000000000000000e+03 3.691395912355046145e-19 3.990000000000000000e+03 3.691204378228041679e-19 3.992000000000000000e+03 3.714485307863984735e-19 3.994000000000000000e+03 3.707611581860613234e-19 3.996000000000000000e+03 3.714965409296788489e-19 3.998000000000000000e+03 3.722576318594575402e-19 4.000000000000000000e+03 3.751669388826938111e-19 4.002000000000000000e+03 3.739617961436815347e-19 4.004000000000000000e+03 3.720151171923984565e-19 4.006000000000000000e+03 3.727804898470745227e-19 4.008000000000000000e+03 3.716250167405164421e-19 4.010000000000000000e+03 3.723805533772224839e-19 4.012000000000000000e+03 3.719553170912748822e-19 4.014000000000000000e+03 3.717708320723028443e-19 4.016000000000000000e+03 3.722234253841810345e-19 4.018000000000000000e+03 3.725970527534422228e-19 4.020000000000000000e+03 3.733917935196882386e-19 4.022000000000000000e+03 3.724131026841001708e-19 4.024000000000000000e+03 3.736888777851354149e-19 4.026000000000000000e+03 3.715440661804683680e-19 4.028000000000000000e+03 3.728621788788774325e-19 4.030000000000000000e+03 3.724201827057740228e-19 4.032000000000000000e+03 3.718952778973466545e-19 4.034000000000000000e+03 3.729602782437863338e-19 4.036000000000000000e+03 3.740716454483446927e-19 4.038000000000000000e+03 3.742529116832515382e-19 4.040000000000000000e+03 3.744769291871779651e-19 4.042000000000000000e+03 3.729181617493868383e-19 4.044000000000000000e+03 3.736090970208017876e-19 4.046000000000000000e+03 3.740052481341995932e-19 4.048000000000000000e+03 3.749440071829251304e-19 4.050000000000000000e+03 3.754263806489347395e-19 4.052000000000000000e+03 3.762347323636454186e-19 4.054000000000000000e+03 3.776544258623403961e-19 4.056000000000000000e+03 3.803434229039186089e-19 4.058000000000000000e+03 3.833051381606465194e-19 4.060000000000000000e+03 3.847511937917437504e-19 4.062000000000000000e+03 3.890542418994743352e-19 4.064000000000000000e+03 3.921934575401030264e-19 4.066000000000000000e+03 3.960516971723767648e-19 4.068000000000000000e+03 4.005202060058407639e-19 4.070000000000000000e+03 4.055395232692127998e-19 4.072000000000000000e+03 4.099937428197610805e-19 4.074000000000000000e+03 4.139263331532284880e-19 4.076000000000000000e+03 4.202833022256474917e-19 4.078000000000000000e+03 4.238736512699946942e-19 4.080000000000000000e+03 4.284351113124234076e-19 4.082000000000000000e+03 4.320872210614892998e-19 4.084000000000000000e+03 4.368702143248762876e-19 4.086000000000000000e+03 4.416440492901501127e-19 4.088000000000000000e+03 4.342958234085063930e-19 4.090000000000000000e+03 4.243961483683407426e-19 4.092000000000000000e+03 4.129115009866648443e-19 4.094000000000000000e+03 3.931982530430900607e-19 4.096000000000000000e+03 3.761456290338330026e-19 4.098000000000000000e+03 4.034528798308687733e-19 4.100000000000000000e+03 4.751412728522880268e-19 4.102000000000000000e+03 4.038298315869722946e-19 4.104000000000000000e+03 3.741309003553277689e-19 4.106000000000000000e+03 3.909975237477464393e-19 4.108000000000000000e+03 4.109984179831661776e-19 4.110000000000000000e+03 4.241557220256019308e-19 4.112000000000000000e+03 4.318060642132316978e-19 4.114000000000000000e+03 4.355522825458190714e-19 4.116000000000000000e+03 4.366916624206406717e-19 4.118000000000000000e+03 4.357988786298527385e-19 4.120000000000000000e+03 4.316184732596643583e-19 4.122000000000000000e+03 4.283093798048588115e-19 4.124000000000000000e+03 4.227075485554371638e-19 4.126000000000000000e+03 4.213636536042742525e-19 4.128000000000000000e+03 4.168991717019956074e-19 4.130000000000000000e+03 4.124669456518779770e-19 4.132000000000000000e+03 4.088389455641897808e-19 4.134000000000000000e+03 4.054367095700829046e-19 4.136000000000000000e+03 4.027330572149850266e-19 4.138000000000000000e+03 3.984851461831697787e-19 4.140000000000000000e+03 3.938050985550894234e-19 4.142000000000000000e+03 3.921143014869333840e-19 4.144000000000000000e+03 3.909810978115071992e-19 4.146000000000000000e+03 3.910133798674195029e-19 4.148000000000000000e+03 3.864788236573213467e-19 4.150000000000000000e+03 3.849370258873080583e-19 4.152000000000000000e+03 3.845890080391715005e-19 4.154000000000000000e+03 3.852210524337366167e-19 4.156000000000000000e+03 3.854291592716716616e-19 4.158000000000000000e+03 3.846509826985522150e-19 4.160000000000000000e+03 3.856602330045479561e-19 4.162000000000000000e+03 3.872422449964433252e-19 4.164000000000000000e+03 3.867611567451534852e-19 4.166000000000000000e+03 3.874561247198630914e-19 4.168000000000000000e+03 3.874589191594358982e-19 4.170000000000000000e+03 3.886155254326560175e-19 4.172000000000000000e+03 3.893312269553039109e-19 4.174000000000000000e+03 3.906878542158403863e-19 4.176000000000000000e+03 3.908656728915495473e-19 4.178000000000000000e+03 3.901558184610200188e-19 4.180000000000000000e+03 3.904216270720924711e-19 4.182000000000000000e+03 3.907957716069322387e-19 4.184000000000000000e+03 3.911623457366666747e-19 4.186000000000000000e+03 3.921061581348049810e-19 4.188000000000000000e+03 3.961813697454869707e-19 4.190000000000000000e+03 3.929093512235372605e-19 4.192000000000000000e+03 3.920423023819589641e-19 4.194000000000000000e+03 3.916657900436887086e-19 4.196000000000000000e+03 3.911089345050548121e-19 4.198000000000000000e+03 3.928624643605154403e-19 4.200000000000000000e+03 3.936528560224674420e-19 4.202000000000000000e+03 3.938392332428108441e-19 4.204000000000000000e+03 3.939660715440431219e-19 4.206000000000000000e+03 3.940953982736868091e-19 4.208000000000000000e+03 3.937766115975419425e-19 4.210000000000000000e+03 3.942134361957011902e-19 4.212000000000000000e+03 4.112313032875617389e-19 4.214000000000000000e+03 4.242555573444390410e-19 4.216000000000000000e+03 3.991727447485234650e-19 4.218000000000000000e+03 3.952632172405119370e-19 4.220000000000000000e+03 3.952099213494162404e-19 4.222000000000000000e+03 3.967924365169041135e-19 4.224000000000000000e+03 3.998210808978902549e-19 4.226000000000000000e+03 4.021487463068402030e-19 4.228000000000000000e+03 3.983781948011431639e-19 4.230000000000000000e+03 3.970259246082233664e-19 4.232000000000000000e+03 4.054795438993468730e-19 4.234000000000000000e+03 4.146828149008288412e-19 4.236000000000000000e+03 4.015408500380818094e-19 4.238000000000000000e+03 4.004931288043335156e-19 4.240000000000000000e+03 3.990025578773500200e-19 4.242000000000000000e+03 3.991512454725459162e-19 4.244000000000000000e+03 4.017656444244191716e-19 4.246000000000000000e+03 3.995280223079971722e-19 4.248000000000000000e+03 4.047775794654735758e-19 4.250000000000000000e+03 4.110631962182476577e-19 4.252000000000000000e+03 4.045006969687266678e-19 4.254000000000000000e+03 3.998553591081619657e-19 4.256000000000000000e+03 4.023989611143760933e-19 4.258000000000000000e+03 3.997041828622969037e-19 4.260000000000000000e+03 4.048894182522213376e-19 4.262000000000000000e+03 4.127911047382392677e-19 4.264000000000000000e+03 4.102510711053930446e-19 4.266000000000000000e+03 4.007522889877382091e-19 4.268000000000000000e+03 4.001483137046858880e-19 4.270000000000000000e+03 4.004161570595833942e-19 4.272000000000000000e+03 3.996279536136750445e-19 4.274000000000000000e+03 4.003808242260969111e-19 4.276000000000000000e+03 4.013285844655721021e-19 4.278000000000000000e+03 4.003100863445011652e-19 4.280000000000000000e+03 4.006305380546939289e-19 4.282000000000000000e+03 4.014520714266685791e-19 4.284000000000000000e+03 4.033772470538219472e-19 4.286000000000000000e+03 4.042022338973429180e-19 4.288000000000000000e+03 4.026964637725060144e-19 4.290000000000000000e+03 4.027461478098133585e-19 4.292000000000000000e+03 4.035436359800865153e-19 4.294000000000000000e+03 4.026001099280368492e-19 4.296000000000000000e+03 4.034671364542127029e-19 4.298000000000000000e+03 4.039130459000264548e-19 4.300000000000000000e+03 4.037251924563694915e-19 4.302000000000000000e+03 4.041311409292001714e-19 4.304000000000000000e+03 4.106940537785746096e-19 4.306000000000000000e+03 4.376744540869188704e-19 4.308000000000000000e+03 4.470437089474474099e-19 4.310000000000000000e+03 4.067799067029144074e-19 4.312000000000000000e+03 4.049205905277112684e-19 4.314000000000000000e+03 4.053418550593644576e-19 4.316000000000000000e+03 4.053637986524701687e-19 4.318000000000000000e+03 4.053692591194208200e-19 4.320000000000000000e+03 4.064831346910842090e-19 4.322000000000000000e+03 4.065448632325684382e-19 4.324000000000000000e+03 4.054601821404052111e-19 4.326000000000000000e+03 4.057579507599208395e-19 4.328000000000000000e+03 4.100502655301980981e-19 4.330000000000000000e+03 4.122086256054086032e-19 4.332000000000000000e+03 4.085054004974970896e-19 4.334000000000000000e+03 4.091593219336544124e-19 4.336000000000000000e+03 4.086437094336877866e-19 4.338000000000000000e+03 4.077122951747292412e-19 4.340000000000000000e+03 4.080905669793438050e-19 4.342000000000000000e+03 4.084115282840321918e-19 4.344000000000000000e+03 4.083935134559468625e-19 4.346000000000000000e+03 4.077763625331597296e-19 4.348000000000000000e+03 4.080236531084624336e-19 4.350000000000000000e+03 4.079148565411700243e-19 4.352000000000000000e+03 4.086704740504871552e-19 4.354000000000000000e+03 4.079700391606056842e-19 4.356000000000000000e+03 4.088741094777754191e-19 4.358000000000000000e+03 4.091765353964959748e-19 4.360000000000000000e+03 4.098690734875987218e-19 4.362000000000000000e+03 4.095676824944801023e-19 4.364000000000000000e+03 4.113227700191115919e-19 4.366000000000000000e+03 4.125207975527681646e-19 4.368000000000000000e+03 4.112095606733439712e-19 4.370000000000000000e+03 4.105125696194902125e-19 4.372000000000000000e+03 4.111071077794806644e-19 4.374000000000000000e+03 4.108801463480693087e-19 4.376000000000000000e+03 4.113512838802066849e-19 4.378000000000000000e+03 4.119229048608467485e-19 4.380000000000000000e+03 4.110784957750437356e-19 4.382000000000000000e+03 4.127720218031106877e-19 4.384000000000000000e+03 4.140613254786649880e-19 4.386000000000000000e+03 4.135208543739548110e-19 4.388000000000000000e+03 4.121576064906922883e-19 4.390000000000000000e+03 4.130821972322733051e-19 4.392000000000000000e+03 4.134490800405129223e-19 4.394000000000000000e+03 4.132894618659157907e-19 4.396000000000000000e+03 4.147655729707335740e-19 4.398000000000000000e+03 4.144401292839560847e-19 4.400000000000000000e+03 4.142339280445631833e-19 4.402000000000000000e+03 4.146007932235103614e-19 4.404000000000000000e+03 4.138771805961651353e-19 4.406000000000000000e+03 4.149054839112183489e-19 4.408000000000000000e+03 4.133755702862261740e-19 4.410000000000000000e+03 4.139768838411440506e-19 4.412000000000000000e+03 4.147127043378555202e-19 4.414000000000000000e+03 4.145327143879654119e-19 4.416000000000000000e+03 4.168175339120800548e-19 4.418000000000000000e+03 4.168835694571681882e-19 4.420000000000000000e+03 4.161426948556107362e-19 4.422000000000000000e+03 4.162547356417381225e-19 4.424000000000000000e+03 4.169192198785530864e-19 4.426000000000000000e+03 4.165466998737536005e-19 4.428000000000000000e+03 4.179476024350674895e-19 4.430000000000000000e+03 4.178063482357094694e-19 4.432000000000000000e+03 4.177608443433525865e-19 4.434000000000000000e+03 4.177747290642757068e-19 4.436000000000000000e+03 4.185948741976667614e-19 4.438000000000000000e+03 4.181274842012750572e-19 4.440000000000000000e+03 4.200037950991002673e-19 4.442000000000000000e+03 4.179977126087718913e-19 4.444000000000000000e+03 4.197089886429742798e-19 4.446000000000000000e+03 4.188959681760991992e-19 4.448000000000000000e+03 4.188418088099629470e-19 4.450000000000000000e+03 4.198968750265520836e-19 4.452000000000000000e+03 4.189204629592321091e-19 4.454000000000000000e+03 4.198739229440469475e-19 4.456000000000000000e+03 4.212482225133992064e-19 4.458000000000000000e+03 4.212683702007137410e-19 4.460000000000000000e+03 4.214349477005438094e-19 4.462000000000000000e+03 4.203284383779518945e-19 4.464000000000000000e+03 4.209826663860322254e-19 4.466000000000000000e+03 4.216343388757732227e-19 4.468000000000000000e+03 4.213136424820888147e-19 4.470000000000000000e+03 4.215606970944082512e-19 4.472000000000000000e+03 4.229590423351509611e-19 4.474000000000000000e+03 4.235300772244084129e-19 4.476000000000000000e+03 4.238366938353961071e-19 4.478000000000000000e+03 4.229382610497934733e-19 4.480000000000000000e+03 4.221008274638601789e-19 4.482000000000000000e+03 4.237190122668081405e-19 4.484000000000000000e+03 4.236546238176377207e-19 4.486000000000000000e+03 4.235297690693702201e-19 4.488000000000000000e+03 4.236014666407966927e-19 4.490000000000000000e+03 4.239024174103032911e-19 4.492000000000000000e+03 4.238230730415492571e-19 4.494000000000000000e+03 4.243559824254957778e-19 4.496000000000000000e+03 4.248625250048257224e-19 4.498000000000000000e+03 4.237201383055650809e-19 4.500000000000000000e+03 4.271553851374788341e-19 4.502000000000000000e+03 4.246982656267124844e-19 4.504000000000000000e+03 4.257084141203494202e-19 4.506000000000000000e+03 4.252961232638093769e-19 4.508000000000000000e+03 4.254301033634466411e-19 4.510000000000000000e+03 4.263234549684584285e-19 4.512000000000000000e+03 4.276681301592991504e-19 4.514000000000000000e+03 4.274661249515613801e-19 4.516000000000000000e+03 4.266131202834170208e-19 4.518000000000000000e+03 4.269113625268298380e-19 4.520000000000000000e+03 4.261933110963489700e-19 4.522000000000000000e+03 4.271490177279424542e-19 4.524000000000000000e+03 4.281838355082750653e-19 4.526000000000000000e+03 4.274411275194041834e-19 4.528000000000000000e+03 4.279537117495597998e-19 4.530000000000000000e+03 4.293252313440976326e-19 4.532000000000000000e+03 4.296914576789721153e-19 4.534000000000000000e+03 4.294150277933087564e-19 4.536000000000000000e+03 4.290584594574850831e-19 4.538000000000000000e+03 4.293106071042342214e-19 4.540000000000000000e+03 4.300375310906260682e-19 4.542000000000000000e+03 4.298210895838509001e-19 4.544000000000000000e+03 4.301568576446370967e-19 4.546000000000000000e+03 4.302249472698297736e-19 4.548000000000000000e+03 4.321690091024380667e-19 4.550000000000000000e+03 4.319162318881701960e-19 4.552000000000000000e+03 4.302919977987162307e-19 4.554000000000000000e+03 4.314668388759303896e-19 4.556000000000000000e+03 4.318720507567367300e-19 4.558000000000000000e+03 4.319366157016814608e-19 4.560000000000000000e+03 4.339107543753121521e-19 4.562000000000000000e+03 4.312524025402501457e-19 4.564000000000000000e+03 4.317563997606052802e-19 4.566000000000000000e+03 4.338375627373811810e-19 4.568000000000000000e+03 4.307390108761486815e-19 4.570000000000000000e+03 4.321280173934749336e-19 4.572000000000000000e+03 4.331105680874687870e-19 4.574000000000000000e+03 4.335590203997956115e-19 4.576000000000000000e+03 4.328596207374182583e-19 4.578000000000000000e+03 4.351330373271359728e-19 4.580000000000000000e+03 4.345566841094912758e-19 4.582000000000000000e+03 4.350225772455503558e-19 4.584000000000000000e+03 4.340964219840482279e-19 4.586000000000000000e+03 4.342794548625421349e-19 4.588000000000000000e+03 4.355999691554533035e-19 4.590000000000000000e+03 4.358704138601001114e-19 4.592000000000000000e+03 4.376682380691001959e-19 4.594000000000000000e+03 4.378277912907665844e-19 4.596000000000000000e+03 4.421936524680426154e-19 4.598000000000000000e+03 4.396816524017262968e-19 4.600000000000000000e+03 4.377701788343238663e-19 4.602000000000000000e+03 4.379910177164286477e-19 4.604000000000000000e+03 4.385744947875268889e-19 4.606000000000000000e+03 4.365857186011108257e-19 4.608000000000000000e+03 4.359333694520678906e-19 4.610000000000000000e+03 4.371332908874991829e-19 4.612000000000000000e+03 4.370172666148166122e-19 4.614000000000000000e+03 4.397224336245244385e-19 4.616000000000000000e+03 4.382187674185200633e-19 4.618000000000000000e+03 4.404010634735806440e-19 4.620000000000000000e+03 4.385212115615573959e-19 4.622000000000000000e+03 4.384516963180075786e-19 4.624000000000000000e+03 4.393962177024204657e-19 4.626000000000000000e+03 4.405862686077428608e-19 4.628000000000000000e+03 4.399859779196730671e-19 4.630000000000000000e+03 4.411645950216000700e-19 4.632000000000000000e+03 4.398815633989870358e-19 4.634000000000000000e+03 4.409494320103707293e-19 4.636000000000000000e+03 4.411077368699361825e-19 4.638000000000000000e+03 4.416698795525176318e-19 4.640000000000000000e+03 4.441094306851819462e-19 4.642000000000000000e+03 4.607538535765817743e-19 4.644000000000000000e+03 4.512681126943920673e-19 4.646000000000000000e+03 4.419751619206655484e-19 4.648000000000000000e+03 4.422426224649731741e-19 4.650000000000000000e+03 4.413305587641443793e-19 4.652000000000000000e+03 4.441786248642366240e-19 4.654000000000000000e+03 4.433140945254532429e-19 4.656000000000000000e+03 4.432952047802937805e-19 4.658000000000000000e+03 4.437234796603791223e-19 4.660000000000000000e+03 4.448717500517091577e-19 4.662000000000000000e+03 4.433886302048901477e-19 4.664000000000000000e+03 4.414176961235493597e-19 4.666000000000000000e+03 4.425744874155565734e-19 4.668000000000000000e+03 4.539272489917289059e-19 4.670000000000000000e+03 4.645125485462908321e-19 4.672000000000000000e+03 4.481073825127299359e-19 4.674000000000000000e+03 4.434512433731306360e-19 4.676000000000000000e+03 4.450393630921244898e-19 4.678000000000000000e+03 4.451416067469483406e-19 4.680000000000000000e+03 4.455941130626344202e-19 4.682000000000000000e+03 4.464297701867283191e-19 4.684000000000000000e+03 4.464530075242906300e-19 4.686000000000000000e+03 4.451245767040878960e-19 4.688000000000000000e+03 4.463002960031087019e-19 4.690000000000000000e+03 4.492252540376986324e-19 4.692000000000000000e+03 4.642752731167859888e-19 4.694000000000000000e+03 4.627429371961178981e-19 4.696000000000000000e+03 4.625032839125146888e-19 4.698000000000000000e+03 4.527903988642701532e-19 4.700000000000000000e+03 4.564941679345050280e-19 4.702000000000000000e+03 4.610647064654862144e-19 4.704000000000000000e+03 4.544821828150005348e-19 4.706000000000000000e+03 4.486040939896920347e-19 4.708000000000000000e+03 4.485620424329007281e-19 4.710000000000000000e+03 4.488453164754425764e-19 4.712000000000000000e+03 4.485298068522415879e-19 4.714000000000000000e+03 4.476979090800733044e-19 4.716000000000000000e+03 4.518129561239161045e-19 4.718000000000000000e+03 4.819564190295995960e-19 4.720000000000000000e+03 4.723782205424751114e-19 4.722000000000000000e+03 4.762299681443871628e-19 4.724000000000000000e+03 4.658912034175976254e-19 4.726000000000000000e+03 4.508470315411836091e-19 4.728000000000000000e+03 4.517200936105497059e-19 4.730000000000000000e+03 4.520651373734801922e-19 4.732000000000000000e+03 4.516220743702168997e-19 4.734000000000000000e+03 4.520602208721687276e-19 4.736000000000000000e+03 4.514896333598196149e-19 4.738000000000000000e+03 4.530275950519428729e-19 4.740000000000000000e+03 4.541473397990670038e-19 4.742000000000000000e+03 4.574449806872942829e-19 4.744000000000000000e+03 4.541690845048876875e-19 4.746000000000000000e+03 4.533338114598290082e-19 4.748000000000000000e+03 4.536709548545281267e-19 4.750000000000000000e+03 4.541696902284713325e-19 4.752000000000000000e+03 4.548464124398070138e-19 4.754000000000000000e+03 4.544354956449475489e-19 4.756000000000000000e+03 4.559759355420494665e-19 4.758000000000000000e+03 4.533444762763868246e-19 4.760000000000000000e+03 4.542334869107365243e-19 4.762000000000000000e+03 4.565304448909632056e-19 4.764000000000000000e+03 4.615092917199900168e-19 4.766000000000000000e+03 4.578656101749140056e-19 4.768000000000000000e+03 4.558102538108824715e-19 4.770000000000000000e+03 4.559827903062579103e-19 4.772000000000000000e+03 4.592247778004739230e-19 4.774000000000000000e+03 4.622777594237753388e-19 4.776000000000000000e+03 4.585244369798838575e-19 4.778000000000000000e+03 4.576215066116823274e-19 4.780000000000000000e+03 4.588232096928381499e-19 4.782000000000000000e+03 4.557426277327217394e-19 4.784000000000000000e+03 4.581868070204918235e-19 4.786000000000000000e+03 4.603759661784142762e-19 4.788000000000000000e+03 4.603777121414026209e-19 4.790000000000000000e+03 4.621443543338970684e-19 4.792000000000000000e+03 4.645450385967479247e-19 4.794000000000000000e+03 4.608508525923393441e-19 4.796000000000000000e+03 4.583891662947907108e-19 4.798000000000000000e+03 4.587587831877908449e-19 4.800000000000000000e+03 4.593108348868977313e-19 4.802000000000000000e+03 4.597178010075556082e-19 4.804000000000000000e+03 4.592859671722366833e-19 4.806000000000000000e+03 4.594539936311051555e-19 4.808000000000000000e+03 4.597099588604267189e-19 4.810000000000000000e+03 4.610775140757058977e-19 4.812000000000000000e+03 4.598193469770039502e-19 4.814000000000000000e+03 4.609876808813697939e-19 4.816000000000000000e+03 4.622003151865399375e-19 4.818000000000000000e+03 4.606050644089614542e-19 4.820000000000000000e+03 4.622718721485981206e-19 4.822000000000000000e+03 4.631607082226701255e-19 4.824000000000000000e+03 4.646048633665545482e-19 4.826000000000000000e+03 4.619567687323105587e-19 4.828000000000000000e+03 4.640552994633100588e-19 4.830000000000000000e+03 4.636359486598051681e-19 4.832000000000000000e+03 4.663301290178244972e-19 4.834000000000000000e+03 4.645294812797522254e-19 4.836000000000000000e+03 4.665987939671043118e-19 4.838000000000000000e+03 4.660311472320198698e-19 4.840000000000000000e+03 4.638751643616207018e-19 4.842000000000000000e+03 4.644476550444053139e-19 4.844000000000000000e+03 4.630626960459726427e-19 4.846000000000000000e+03 4.665699300697468925e-19 4.848000000000000000e+03 4.646857546112287827e-19 4.850000000000000000e+03 4.679574275515228908e-19 4.852000000000000000e+03 4.669866880193857970e-19 4.854000000000000000e+03 4.673153424920181718e-19 4.856000000000000000e+03 4.684511591112695347e-19 4.858000000000000000e+03 4.682623678337787844e-19 4.860000000000000000e+03 4.657605571936359779e-19 4.862000000000000000e+03 4.671769276918783929e-19 4.864000000000000000e+03 4.682364480198819193e-19 4.866000000000000000e+03 4.667341771891769342e-19 4.868000000000000000e+03 4.669190394933056421e-19 4.870000000000000000e+03 4.661998095481828018e-19 4.872000000000000000e+03 4.684535665635931538e-19 4.874000000000000000e+03 4.677512413509561346e-19 4.876000000000000000e+03 4.681976703982857003e-19 4.878000000000000000e+03 4.671634653695968575e-19 4.880000000000000000e+03 4.684501414681038104e-19 4.882000000000000000e+03 4.686851260496803524e-19 4.884000000000000000e+03 4.693152674251840183e-19 4.886000000000000000e+03 4.700437634774075948e-19 4.888000000000000000e+03 4.700295593844340256e-19 4.890000000000000000e+03 4.692023419652139859e-19 4.892000000000000000e+03 4.712725114829493711e-19 4.894000000000000000e+03 4.717148022692227184e-19 4.896000000000000000e+03 4.706282556253839688e-19 4.898000000000000000e+03 4.707284812300103860e-19 4.900000000000000000e+03 4.709901410879654023e-19 4.902000000000000000e+03 4.707921180539933736e-19 4.904000000000000000e+03 4.703786834383076570e-19 4.906000000000000000e+03 4.723862178168318818e-19 4.908000000000000000e+03 4.714724049575910307e-19 4.910000000000000000e+03 4.730566104431015671e-19 4.912000000000000000e+03 4.743876966261379644e-19 4.914000000000000000e+03 4.725443038882989364e-19 4.916000000000000000e+03 4.725972189101091550e-19 4.918000000000000000e+03 4.733097979680796678e-19 4.920000000000000000e+03 4.743685030336769159e-19 4.922000000000000000e+03 4.745971262560121797e-19 4.924000000000000000e+03 4.743488832602115277e-19 4.926000000000000000e+03 4.762984132963986146e-19 4.928000000000000000e+03 4.747688993204744796e-19 4.930000000000000000e+03 4.748129320198454118e-19 4.932000000000000000e+03 4.759595339818463806e-19 4.934000000000000000e+03 4.770580849295658965e-19 4.936000000000000000e+03 4.746638401038423763e-19 4.938000000000000000e+03 4.757829095567936141e-19 4.940000000000000000e+03 4.764519979659900077e-19 4.942000000000000000e+03 4.760379877857578250e-19 4.944000000000000000e+03 4.759716646780700502e-19 4.946000000000000000e+03 4.777168556255033805e-19 4.948000000000000000e+03 4.775034397512988784e-19 4.950000000000000000e+03 4.776459918101798807e-19 4.952000000000000000e+03 4.773952636536460187e-19 4.954000000000000000e+03 4.776135143126044464e-19 4.956000000000000000e+03 4.785114342363922029e-19 4.958000000000000000e+03 4.799145076721118902e-19 4.960000000000000000e+03 4.806343287482851355e-19 4.962000000000000000e+03 4.795008161951680760e-19 4.964000000000000000e+03 4.795278433323026425e-19 4.966000000000000000e+03 4.782371053515349840e-19 4.968000000000000000e+03 4.780526346633969253e-19 4.970000000000000000e+03 4.794602516734593858e-19 4.972000000000000000e+03 4.811089077700069097e-19 4.974000000000000000e+03 4.802807568703416922e-19 4.976000000000000000e+03 4.815463145831127143e-19 4.978000000000000000e+03 4.843753803291669700e-19 4.980000000000000000e+03 4.818678473177987663e-19 4.982000000000000000e+03 4.804461093397962738e-19 4.984000000000000000e+03 4.811842943131021083e-19 4.986000000000000000e+03 4.838404528152986160e-19 4.988000000000000000e+03 4.828688533519332720e-19 4.990000000000000000e+03 4.842299603848368676e-19 4.992000000000000000e+03 4.844885751585394281e-19 4.994000000000000000e+03 4.853664079687784745e-19 4.996000000000000000e+03 4.839658143737895487e-19 4.998000000000000000e+03 4.951321096154743716e-19 5.000000000000000000e+03 5.251936508458535491e-19 5.002000000000000000e+03 4.939806732189425191e-19 5.004000000000000000e+03 4.842184076209308712e-19 5.006000000000000000e+03 4.840662139881925863e-19 5.008000000000000000e+03 4.849730570547118379e-19 5.010000000000000000e+03 4.842087153197945681e-19 5.012000000000000000e+03 4.851393890605841302e-19 5.014000000000000000e+03 4.846272928208366191e-19 5.016000000000000000e+03 4.852986206004040244e-19 5.018000000000000000e+03 4.835180824830563204e-19 5.020000000000000000e+03 4.848009990974057153e-19 5.022000000000000000e+03 4.851778205525598815e-19 5.024000000000000000e+03 4.877549964097056933e-19 5.026000000000000000e+03 4.871746436925258599e-19 5.028000000000000000e+03 4.880239677291894543e-19 5.030000000000000000e+03 4.861976957242651628e-19 5.032000000000000000e+03 4.876791226473328947e-19 5.034000000000000000e+03 4.881858365930138478e-19 5.036000000000000000e+03 4.874529419679618594e-19 5.038000000000000000e+03 4.883969895661285005e-19 5.040000000000000000e+03 4.892615195041881640e-19 5.042000000000000000e+03 4.888011760746416526e-19 5.044000000000000000e+03 4.889475301809052213e-19 5.046000000000000000e+03 4.886338070247174299e-19 5.048000000000000000e+03 4.897087375999761717e-19 5.050000000000000000e+03 4.885869739520940325e-19 5.052000000000000000e+03 4.903678057628508476e-19 5.054000000000000000e+03 4.923954027287394234e-19 5.056000000000000000e+03 4.903856575114067181e-19 5.058000000000000000e+03 4.913623195035722582e-19 5.060000000000000000e+03 4.896310360430780274e-19 5.062000000000000000e+03 4.917572103982721007e-19 5.064000000000000000e+03 4.918994860093609972e-19 5.066000000000000000e+03 4.929638162832508894e-19 5.068000000000000000e+03 4.929967992301076348e-19 5.070000000000000000e+03 4.927091112422708776e-19 5.072000000000000000e+03 4.914167002504764668e-19 5.074000000000000000e+03 4.925065320463878415e-19 5.076000000000000000e+03 4.934817819824802684e-19 5.078000000000000000e+03 4.921974421295226355e-19 5.080000000000000000e+03 4.934007476071171022e-19 5.082000000000000000e+03 4.924889452389927867e-19 5.084000000000000000e+03 4.927608408093420471e-19 5.086000000000000000e+03 4.935110217961150461e-19 5.088000000000000000e+03 4.953249210986479285e-19 5.090000000000000000e+03 4.958168283919839511e-19 5.092000000000000000e+03 4.964808233499040510e-19 5.094000000000000000e+03 4.944614691035086124e-19 5.096000000000000000e+03 4.951702839252943483e-19 5.098000000000000000e+03 4.965505531164344196e-19 5.100000000000000000e+03 4.974061896918350132e-19 5.102000000000000000e+03 4.976785277841198642e-19 5.104000000000000000e+03 4.979249611776348620e-19 5.106000000000000000e+03 5.023919736491173657e-19 5.108000000000000000e+03 5.032758603065462797e-19 5.110000000000000000e+03 4.970641922832064770e-19 5.112000000000000000e+03 4.965352795177426109e-19 5.114000000000000000e+03 4.977271173687675132e-19 5.116000000000000000e+03 4.976608352368192419e-19 5.118000000000000000e+03 4.979207424894062615e-19 5.120000000000000000e+03 4.981463217374466967e-19 5.122000000000000000e+03 4.998014042059161480e-19 5.124000000000000000e+03 5.032207023978726382e-19 5.126000000000000000e+03 5.106566908335159355e-19 5.128000000000000000e+03 5.181084022724212299e-19 5.130000000000000000e+03 5.154441193436700926e-19 5.132000000000000000e+03 5.023961463268228761e-19 5.134000000000000000e+03 4.975947577979572785e-19 5.136000000000000000e+03 4.981885246068679251e-19 5.138000000000000000e+03 5.000508630508060375e-19 5.140000000000000000e+03 5.079396464697174761e-19 5.142000000000000000e+03 5.107117198813840936e-19 5.144000000000000000e+03 5.005625656584769965e-19 5.146000000000000000e+03 5.005643838475544338e-19 5.148000000000000000e+03 5.011227137191671770e-19 5.150000000000000000e+03 5.063936789130668133e-19 5.152000000000000000e+03 5.065785874175512666e-19 5.154000000000000000e+03 5.196614340045791557e-19 5.156000000000000000e+03 5.188766402883558775e-19 5.158000000000000000e+03 5.028698198395467832e-19 5.160000000000000000e+03 5.001237144849404756e-19 5.162000000000000000e+03 5.025100600774318702e-19 5.164000000000000000e+03 5.031094280444955210e-19 5.166000000000000000e+03 5.013124433006444361e-19 5.168000000000000000e+03 5.018790871126950304e-19 5.170000000000000000e+03 5.027295664487648287e-19 5.172000000000000000e+03 5.028802130295720793e-19 5.174000000000000000e+03 5.172411506627758459e-19 5.176000000000000000e+03 5.259268592421590671e-19 5.178000000000000000e+03 5.152155545285638957e-19 5.180000000000000000e+03 5.229387727363679552e-19 5.182000000000000000e+03 5.385595112585978985e-19 5.184000000000000000e+03 5.161991475082885051e-19 5.186000000000000000e+03 5.098309658471701376e-19 5.188000000000000000e+03 5.081154224529468984e-19 5.190000000000000000e+03 5.091135435365095050e-19 5.192000000000000000e+03 5.093372306609723270e-19 5.194000000000000000e+03 5.099917703290794416e-19 5.196000000000000000e+03 5.099363504373308601e-19 5.198000000000000000e+03 5.101051794485401429e-19 5.200000000000000000e+03 5.115962433679529990e-19 5.202000000000000000e+03 5.116136559117395482e-19 5.204000000000000000e+03 5.085858798620848654e-19 5.206000000000000000e+03 5.074798218179505079e-19 5.208000000000000000e+03 5.098627005471311288e-19 5.210000000000000000e+03 5.137810329174797557e-19 5.212000000000000000e+03 5.098725455540869569e-19 5.214000000000000000e+03 5.085732846320610847e-19 5.216000000000000000e+03 5.087046627126757766e-19 5.218000000000000000e+03 5.103273848958091130e-19 5.220000000000000000e+03 5.100286752824334708e-19 5.222000000000000000e+03 5.094359953141630553e-19 5.224000000000000000e+03 5.113538917757580976e-19 5.226000000000000000e+03 5.119542563797616209e-19 5.228000000000000000e+03 5.145748510446293810e-19 5.230000000000000000e+03 5.154948673914383696e-19 5.232000000000000000e+03 5.124858116781197584e-19 5.234000000000000000e+03 5.142776953653335550e-19 5.236000000000000000e+03 5.148622874495946094e-19 5.238000000000000000e+03 5.172855634058587928e-19 5.240000000000000000e+03 5.164993382562888672e-19 5.242000000000000000e+03 5.138511851618665077e-19 5.244000000000000000e+03 5.120853737255353773e-19 5.246000000000000000e+03 5.130272906913191038e-19 5.248000000000000000e+03 5.132596127169965594e-19 5.250000000000000000e+03 5.133833510407591761e-19 5.252000000000000000e+03 5.122790516163594531e-19 5.254000000000000000e+03 5.138599159050566788e-19 5.256000000000000000e+03 5.172547188571546395e-19 5.258000000000000000e+03 5.191180685539207501e-19 5.260000000000000000e+03 5.157925516853611671e-19 5.262000000000000000e+03 5.154744849922818114e-19 5.264000000000000000e+03 5.143820054528310045e-19 5.266000000000000000e+03 5.152586347106069000e-19 5.268000000000000000e+03 5.170568712203019036e-19 5.270000000000000000e+03 5.164318016071254846e-19 5.272000000000000000e+03 5.155345024480079341e-19 5.274000000000000000e+03 5.153817444137788749e-19 5.276000000000000000e+03 5.152019271618683277e-19 5.278000000000000000e+03 5.145427766326820459e-19 5.280000000000000000e+03 5.143582982321270952e-19 5.282000000000000000e+03 5.143534218697125732e-19 5.284000000000000000e+03 5.145473269837796846e-19 5.286000000000000000e+03 5.138511477999560111e-19 5.288000000000000000e+03 5.114639042164347247e-19 5.290000000000000000e+03 5.143003006722088866e-19 5.292000000000000000e+03 5.144294056804798623e-19 5.294000000000000000e+03 5.134794657237090112e-19 5.296000000000000000e+03 5.131949072473070231e-19 5.298000000000000000e+03 5.144593708430221874e-19 5.300000000000000000e+03 5.148176829914022184e-19 5.302000000000000000e+03 5.143277784090711352e-19 5.304000000000000000e+03 5.145617873421797602e-19 5.306000000000000000e+03 5.138988203702077722e-19 5.308000000000000000e+03 5.137621106959057904e-19 5.310000000000000000e+03 5.127466859326017576e-19 5.312000000000000000e+03 5.138355686324935356e-19 5.314000000000000000e+03 5.143605711233666632e-19 5.316000000000000000e+03 5.145060100000776902e-19 5.318000000000000000e+03 5.133619714204290078e-19 5.320000000000000000e+03 5.128807989784803592e-19 5.322000000000000000e+03 5.140623787689392618e-19 5.324000000000000000e+03 5.141004262050139677e-19 5.326000000000000000e+03 5.164847138345645617e-19 5.328000000000000000e+03 5.147056831123892147e-19 5.330000000000000000e+03 5.173413786054005191e-19 5.332000000000000000e+03 5.202831217308815342e-19 5.334000000000000000e+03 5.179687283165509281e-19 5.336000000000000000e+03 5.182297585144246595e-19 5.338000000000000000e+03 5.173387239022278100e-19 5.340000000000000000e+03 5.191756721361095002e-19 5.342000000000000000e+03 5.186775264050187572e-19 5.344000000000000000e+03 5.168672308719005112e-19 5.346000000000000000e+03 5.189323896195918582e-19 5.348000000000000000e+03 5.177554679760530885e-19 5.350000000000000000e+03 5.178912352596630866e-19 5.352000000000000000e+03 5.180440595797897702e-19 5.354000000000000000e+03 5.178163542453616983e-19 5.356000000000000000e+03 5.192233163172227902e-19 5.358000000000000000e+03 5.221126667257542078e-19 5.360000000000000000e+03 5.229062897289763876e-19 5.362000000000000000e+03 5.244018331919073051e-19 5.364000000000000000e+03 5.226443126095523373e-19 5.366000000000000000e+03 5.206467827045692610e-19 5.368000000000000000e+03 5.222351555978091787e-19 5.370000000000000000e+03 5.215188266883350880e-19 5.372000000000000000e+03 5.208890812434332367e-19 5.374000000000000000e+03 5.218442479516073498e-19 5.376000000000000000e+03 5.221560598045407466e-19 5.378000000000000000e+03 5.221295533006840244e-19 5.380000000000000000e+03 5.222298874313773929e-19 5.382000000000000000e+03 5.231610518821150605e-19 5.384000000000000000e+03 5.227419460644135930e-19 5.386000000000000000e+03 5.228168390291275233e-19 5.388000000000000000e+03 5.238892774608275373e-19 5.390000000000000000e+03 5.268154058979889254e-19 5.392000000000000000e+03 5.291659669548491214e-19 5.394000000000000000e+03 5.630797594008100312e-19 5.396000000000000000e+03 5.971791603189282799e-19 5.398000000000000000e+03 5.634313061366876437e-19 5.400000000000000000e+03 5.355205948495492956e-19 5.402000000000000000e+03 5.268689032598845399e-19 5.404000000000000000e+03 5.269770901290356447e-19 5.406000000000000000e+03 5.273882865193822424e-19 5.408000000000000000e+03 5.277116916316838037e-19 5.410000000000000000e+03 5.252210545260702559e-19 5.412000000000000000e+03 5.268880113327348847e-19 5.414000000000000000e+03 5.249475758188590328e-19 5.416000000000000000e+03 5.267049757742534156e-19 5.418000000000000000e+03 5.284285973786610462e-19 5.420000000000000000e+03 5.284920228451502502e-19 5.422000000000000000e+03 5.304429407761094079e-19 5.424000000000000000e+03 5.282754664654117288e-19 5.426000000000000000e+03 5.302046930631318463e-19 5.428000000000000000e+03 5.312445849221394264e-19 5.430000000000000000e+03 5.308378030788570673e-19 5.432000000000000000e+03 5.309560541591075632e-19 5.434000000000000000e+03 5.300271542007519467e-19 5.436000000000000000e+03 5.304370023490097869e-19 5.438000000000000000e+03 5.304122464322196649e-19 5.440000000000000000e+03 5.320562148880145243e-19 5.442000000000000000e+03 5.330621212763954703e-19 5.444000000000000000e+03 5.313758762534130710e-19 5.446000000000000000e+03 5.308959783349246175e-19 5.448000000000000000e+03 5.311238709630656637e-19 5.450000000000000000e+03 5.316062640059711090e-19 5.452000000000000000e+03 5.309987290973232542e-19 5.454000000000000000e+03 5.304930962429207732e-19 5.456000000000000000e+03 5.324623832915229683e-19 5.458000000000000000e+03 5.354449256857774522e-19 5.460000000000000000e+03 5.334597990402178312e-19 5.462000000000000000e+03 5.344049021916355333e-19 5.464000000000000000e+03 5.339944386528859596e-19 5.466000000000000000e+03 5.326672769823429120e-19 5.468000000000000000e+03 5.326168234728422200e-19 5.470000000000000000e+03 5.337607643145507718e-19 5.472000000000000000e+03 5.336341685025573711e-19 5.474000000000000000e+03 5.321862136229457683e-19 5.476000000000000000e+03 5.332492177867656667e-19 5.478000000000000000e+03 5.342242102605602086e-19 5.480000000000000000e+03 5.334988020298334223e-19 5.482000000000000000e+03 5.347596043806945387e-19 5.484000000000000000e+03 5.360556641796159645e-19 5.486000000000000000e+03 5.364910050944593523e-19 5.488000000000000000e+03 5.348680871896614640e-19 5.490000000000000000e+03 5.364224114877520306e-19 5.492000000000000000e+03 5.368596008988646028e-19 5.494000000000000000e+03 5.364257321128449813e-19 5.496000000000000000e+03 5.371952315437038805e-19 5.498000000000000000e+03 5.383906573060927830e-19 5.500000000000000000e+03 5.372898932613090822e-19 5.502000000000000000e+03 5.372689002427189898e-19 5.504000000000000000e+03 5.380691277087231141e-19 5.506000000000000000e+03 5.417653254970410314e-19 5.508000000000000000e+03 5.412076919588482577e-19 5.510000000000000000e+03 5.386499848645355720e-19 5.512000000000000000e+03 5.383302008611550259e-19 5.514000000000000000e+03 5.395719333874745731e-19 5.516000000000000000e+03 5.456613352672933290e-19 5.518000000000000000e+03 5.603434541872215387e-19 5.520000000000000000e+03 5.515153363793099906e-19 5.522000000000000000e+03 5.427581234679089991e-19 5.524000000000000000e+03 5.400300467733424441e-19 5.526000000000000000e+03 5.416141782947768765e-19 5.528000000000000000e+03 5.434620897821067840e-19 5.530000000000000000e+03 5.416275806703248217e-19 5.532000000000000000e+03 5.427485789174577785e-19 5.534000000000000000e+03 5.422884076315668308e-19 5.536000000000000000e+03 5.418079567821755956e-19 5.538000000000000000e+03 5.427249717538217054e-19 5.540000000000000000e+03 5.419662223700100489e-19 5.542000000000000000e+03 5.425840585220869232e-19 5.544000000000000000e+03 5.419722384424000845e-19 5.546000000000000000e+03 5.419763704697302889e-19 5.548000000000000000e+03 5.401299161273121873e-19 5.550000000000000000e+03 5.411097375247789737e-19 5.552000000000000000e+03 5.425906188351426008e-19 5.554000000000000000e+03 5.437469185396854336e-19 5.556000000000000000e+03 5.438279032004869072e-19 5.558000000000000000e+03 5.451384738865098962e-19 5.560000000000000000e+03 5.453528601594435691e-19 5.562000000000000000e+03 5.428011615477095940e-19 5.564000000000000000e+03 5.444432413226715421e-19 5.566000000000000000e+03 5.449141728643199516e-19 5.568000000000000000e+03 5.460478471543204907e-19 5.570000000000000000e+03 5.434324103215646367e-19 5.572000000000000000e+03 5.458973804538435538e-19 5.574000000000000000e+03 5.478597003819682214e-19 5.576000000000000000e+03 5.459524194276755781e-19 5.578000000000000000e+03 5.467115401241349948e-19 5.580000000000000000e+03 5.464272215480700709e-19 5.582000000000000000e+03 5.484332301720999281e-19 5.584000000000000000e+03 5.486522651148013599e-19 5.586000000000000000e+03 5.481200400771249121e-19 5.588000000000000000e+03 5.496283234282321512e-19 5.590000000000000000e+03 5.474981391959693628e-19 5.592000000000000000e+03 5.556805433714914327e-19 5.594000000000000000e+03 5.606327486524334847e-19 5.596000000000000000e+03 5.508304278938185603e-19 5.598000000000000000e+03 5.543192546204413776e-19 5.600000000000000000e+03 5.541397860613530684e-19 5.602000000000000000e+03 5.548358409853785103e-19 5.604000000000000000e+03 5.603071559044017303e-19 5.606000000000000000e+03 5.622146769886052724e-19 5.608000000000000000e+03 5.626365661545359045e-19 5.610000000000000000e+03 5.638698874232600368e-19 5.612000000000000000e+03 5.694895672221124467e-19 5.614000000000000000e+03 5.724249323031061625e-19 5.616000000000000000e+03 5.681079710563179554e-19 5.618000000000000000e+03 5.689516908418091292e-19 5.620000000000000000e+03 5.628581507894489322e-19 5.622000000000000000e+03 5.618788077769081572e-19 5.624000000000000000e+03 5.618214561702991256e-19 5.626000000000000000e+03 5.603694031770836129e-19 5.628000000000000000e+03 5.571754464210977471e-19 5.630000000000000000e+03 5.574806630669859784e-19 5.632000000000000000e+03 5.616380153678111353e-19 5.634000000000000000e+03 5.608460258977055295e-19 5.636000000000000000e+03 5.562502491930121454e-19 5.638000000000000000e+03 5.590985514933178822e-19 5.640000000000000000e+03 5.692089666209955976e-19 5.642000000000000000e+03 5.664904341149191598e-19 5.644000000000000000e+03 5.579542505982273811e-19 5.646000000000000000e+03 5.571669741230390970e-19 5.648000000000000000e+03 5.575167533147646615e-19 5.650000000000000000e+03 5.576294959492803019e-19 5.652000000000000000e+03 5.590549871308481814e-19 5.654000000000000000e+03 5.627511239925727010e-19 5.656000000000000000e+03 5.578269209342042690e-19 5.658000000000000000e+03 5.576527520869945801e-19 5.660000000000000000e+03 5.569280635063418950e-19 5.662000000000000000e+03 5.563552684969639560e-19 5.664000000000000000e+03 5.585887607057630405e-19 5.666000000000000000e+03 5.613839089340818609e-19 5.668000000000000000e+03 5.605472865168191476e-19 5.670000000000000000e+03 5.609919930822485694e-19 5.672000000000000000e+03 5.641984639074033031e-19 5.674000000000000000e+03 5.647657409404473380e-19 5.676000000000000000e+03 5.677760639190378075e-19 5.678000000000000000e+03 5.679658431431911351e-19 5.680000000000000000e+03 5.638930262702676986e-19 5.682000000000000000e+03 5.629917484875813621e-19 5.684000000000000000e+03 5.608806218999737220e-19 5.686000000000000000e+03 5.622454481767625660e-19 5.688000000000000000e+03 5.619294847069270912e-19 5.690000000000000000e+03 5.596116983927849994e-19 5.692000000000000000e+03 5.585468777301976053e-19 5.694000000000000000e+03 5.596093777741598925e-19 5.696000000000000000e+03 5.573760070029045731e-19 5.698000000000000000e+03 5.608855249977176719e-19 5.700000000000000000e+03 5.611431484455864562e-19 5.702000000000000000e+03 5.602799482373560206e-19 5.704000000000000000e+03 5.600265651944932229e-19 5.706000000000000000e+03 5.633706417327179939e-19 5.708000000000000000e+03 5.628307010327397754e-19 5.710000000000000000e+03 5.612238348719454105e-19 5.712000000000000000e+03 5.593499837542055795e-19 5.714000000000000000e+03 5.607475548570003805e-19 5.716000000000000000e+03 5.624211199939894011e-19 5.718000000000000000e+03 5.635335699688049649e-19 5.720000000000000000e+03 5.637036013348610700e-19 5.722000000000000000e+03 5.636839571558277891e-19 5.724000000000000000e+03 5.631437955030156404e-19 5.726000000000000000e+03 5.646094516659036266e-19 5.728000000000000000e+03 5.636561739567640886e-19 5.730000000000000000e+03 5.633859638227059207e-19 5.732000000000000000e+03 5.644961618486181239e-19 5.734000000000000000e+03 5.650237872438565160e-19 5.736000000000000000e+03 5.641197656266972753e-19 5.738000000000000000e+03 5.647709066557334183e-19 5.740000000000000000e+03 5.626836968977732153e-19 5.742000000000000000e+03 5.642159241890112353e-19 5.744000000000000000e+03 5.647785749649258236e-19 5.746000000000000000e+03 5.651404358472340221e-19 5.748000000000000000e+03 5.657773527482780223e-19 5.750000000000000000e+03 5.669615304821727528e-19 5.752000000000000000e+03 5.660442252106562643e-19 5.754000000000000000e+03 5.664503905815140473e-19 5.756000000000000000e+03 5.667072113784317118e-19 5.758000000000000000e+03 5.698219975239078390e-19 5.760000000000000000e+03 5.703816678671386599e-19 5.762000000000000000e+03 5.672473114753230979e-19 5.764000000000000000e+03 5.697860303419621407e-19 5.766000000000000000e+03 5.698005352638492056e-19 5.768000000000000000e+03 5.697019645619884835e-19 5.770000000000000000e+03 5.706031708294360698e-19 5.772000000000000000e+03 5.705404789168208588e-19 5.774000000000000000e+03 5.691476970326531910e-19 5.776000000000000000e+03 5.701676233829059899e-19 5.778000000000000000e+03 5.690656112252263849e-19 5.780000000000000000e+03 5.719631320615080507e-19 5.782000000000000000e+03 5.715107372929400925e-19 5.784000000000000000e+03 5.712786985373289626e-19 5.786000000000000000e+03 5.688539512950276677e-19 5.788000000000000000e+03 5.683604303898914593e-19 5.790000000000000000e+03 5.712124094650828845e-19 5.792000000000000000e+03 5.722981925043232216e-19 5.794000000000000000e+03 5.710441053945304557e-19 5.796000000000000000e+03 5.711149657714286330e-19 5.798000000000000000e+03 5.712705850900635673e-19 5.800000000000000000e+03 5.709113647367140442e-19 5.802000000000000000e+03 5.730178521762105924e-19 5.804000000000000000e+03 5.730966808810169654e-19 5.806000000000000000e+03 5.733417277253608259e-19 5.808000000000000000e+03 5.746270561036452732e-19 5.810000000000000000e+03 5.722493911193209391e-19 5.812000000000000000e+03 5.734382715032549992e-19 5.814000000000000000e+03 5.728731157181651131e-19 5.816000000000000000e+03 5.724604283695297428e-19 5.818000000000000000e+03 5.721807399265105600e-19 5.820000000000000000e+03 5.728259164639994614e-19 5.822000000000000000e+03 5.730741766029004456e-19 5.824000000000000000e+03 5.725892495817439546e-19 5.826000000000000000e+03 5.736542301191000910e-19 5.828000000000000000e+03 5.746665354930668449e-19 5.830000000000000000e+03 5.736477113849396272e-19 5.832000000000000000e+03 5.750233528742835265e-19 5.834000000000000000e+03 5.783591354737365356e-19 5.836000000000000000e+03 5.763611572405045315e-19 5.838000000000000000e+03 5.757121972853837570e-19 5.840000000000000000e+03 5.771158423389040756e-19 5.842000000000000000e+03 5.762196970719892892e-19 5.844000000000000000e+03 5.789518745452697963e-19 5.846000000000000000e+03 5.783408817761942412e-19 5.848000000000000000e+03 5.775654196705368837e-19 5.850000000000000000e+03 5.767496016645455402e-19 5.852000000000000000e+03 5.777494873091286592e-19 5.854000000000000000e+03 5.794148493074078836e-19 5.856000000000000000e+03 5.803240046753780365e-19 5.858000000000000000e+03 5.830928637788365117e-19 5.860000000000000000e+03 5.873446161591196279e-19 5.862000000000000000e+03 5.886705037655632536e-19 5.864000000000000000e+03 7.046602433288233100e-19 5.866000000000000000e+03 8.503586806193807541e-19 5.868000000000000000e+03 6.423739393497414645e-19 5.870000000000000000e+03 5.848978898748941578e-19 5.872000000000000000e+03 5.831479209405276035e-19 5.874000000000000000e+03 5.818718823245459825e-19 5.876000000000000000e+03 5.833906746824910736e-19 5.878000000000000000e+03 5.811393858009898864e-19 5.880000000000000000e+03 5.814244319743270638e-19 5.882000000000000000e+03 5.830466870027754725e-19 5.884000000000000000e+03 5.830864724457404559e-19 5.886000000000000000e+03 5.811449891359452398e-19 5.888000000000000000e+03 5.815573362886445675e-19 5.890000000000000000e+03 5.823780289338301042e-19 5.892000000000000000e+03 5.833044757116263191e-19 5.894000000000000000e+03 5.842808007629926973e-19 5.896000000000000000e+03 5.845039090672380159e-19 5.898000000000000000e+03 5.835357676243933950e-19 5.900000000000000000e+03 5.836483773158013306e-19 5.902000000000000000e+03 5.853188440893256244e-19 5.904000000000000000e+03 5.873541250261051207e-19 5.906000000000000000e+03 5.855046762524562733e-19 5.908000000000000000e+03 5.856141643412252230e-19 5.910000000000000000e+03 5.850205512391034492e-19 5.912000000000000000e+03 5.835203323891840940e-19 5.914000000000000000e+03 5.852626289649355938e-19 5.916000000000000000e+03 5.866293963553041503e-19 5.918000000000000000e+03 5.882871524093734275e-19 5.920000000000000000e+03 5.869831311502275057e-19 5.922000000000000000e+03 5.963111802872024475e-19 5.924000000000000000e+03 5.955078246499429949e-19 5.926000000000000000e+03 5.888872407545801060e-19 5.928000000000000000e+03 5.882634979943860383e-19 5.930000000000000000e+03 5.912005412960103169e-19 5.932000000000000000e+03 6.714001809093900681e-19 5.934000000000000000e+03 9.125036887722935768e-19 5.936000000000000000e+03 8.645542421245639236e-19 5.938000000000000000e+03 1.011339657523548822e-18 5.940000000000000000e+03 1.107823481032093060e-18 5.942000000000000000e+03 6.927874924650594984e-19 5.944000000000000000e+03 1.990658242280523895e-18 5.946000000000000000e+03 3.018194551656599478e-18 5.948000000000000000e+03 2.583858177699487624e-18 5.950000000000000000e+03 3.849434662791603428e-18 5.952000000000000000e+03 1.865424749952999183e-18 5.954000000000000000e+03 7.057117684341015096e-19 5.956000000000000000e+03 8.481105538063045477e-19 5.958000000000000000e+03 1.182462265528908538e-18 5.960000000000000000e+03 1.737449872200209976e-18 5.962000000000000000e+03 1.447060880493409736e-18 5.964000000000000000e+03 1.127539105340411747e-18 5.966000000000000000e+03 8.027471130925968265e-19 5.968000000000000000e+03 7.218248364261721560e-19 5.970000000000000000e+03 7.481127860129252480e-19 5.972000000000000000e+03 9.782856032664871625e-19 5.974000000000000000e+03 1.209472246169001462e-18 5.976000000000000000e+03 7.239454890436206548e-19 5.978000000000000000e+03 6.467299274000062318e-19 5.980000000000000000e+03 6.185085605019349095e-19 5.982000000000000000e+03 6.349441901380654466e-19 5.984000000000000000e+03 6.056415787176697189e-19 5.986000000000000000e+03 5.979675323987642739e-19 5.988000000000000000e+03 5.984534379074529538e-19 5.990000000000000000e+03 5.983510752727577991e-19 5.992000000000000000e+03 5.979356869793329476e-19 5.994000000000000000e+03 5.977792419562721477e-19 5.996000000000000000e+03 5.973141815042962000e-19 5.998000000000000000e+03 6.361377746091573608e-19 6.000000000000000000e+03 7.232845803008317563e-19 6.002000000000000000e+03 6.216567147005332709e-19 6.004000000000000000e+03 6.002203075375009878e-19 6.006000000000000000e+03 6.018599276681378995e-19 6.008000000000000000e+03 5.994734179937513029e-19 6.010000000000000000e+03 5.999203411845009010e-19 6.012000000000000000e+03 6.000790042203717870e-19 6.014000000000000000e+03 6.012892261606100390e-19 6.016000000000000000e+03 5.993799817002206205e-19 6.018000000000000000e+03 6.015054269647774208e-19 6.020000000000000000e+03 6.018072024284258250e-19 6.022000000000000000e+03 6.025028365276607104e-19 6.024000000000000000e+03 6.019559203998646532e-19 6.026000000000000000e+03 6.003850628856604140e-19 6.028000000000000000e+03 5.993375604731100322e-19 6.030000000000000000e+03 5.999246666300259547e-19 6.032000000000000000e+03 6.027137736207872693e-19 6.034000000000000000e+03 6.088292364557267968e-19 6.036000000000000000e+03 7.165513386897034474e-19 6.038000000000000000e+03 3.830574205185999995e-18 6.040000000000000000e+03 5.413904302531489505e-18 6.042000000000000000e+03 6.071670750708700471e-18 6.044000000000000000e+03 4.853399784599487494e-18 6.046000000000000000e+03 9.639013106638247123e-19 6.048000000000000000e+03 6.335548687015854270e-18 6.050000000000000000e+03 1.117298871649013735e-17 6.052000000000000000e+03 5.360480983106549234e-18 6.054000000000000000e+03 8.889216914533615289e-18 6.056000000000000000e+03 7.231883597951661809e-18 6.058000000000000000e+03 1.105146376973388216e-18 6.060000000000000000e+03 6.405448873402500664e-19 6.062000000000000000e+03 6.428877004301148137e-19 6.064000000000000000e+03 6.200078637212676419e-19 6.066000000000000000e+03 6.249271193619342576e-19 6.068000000000000000e+03 6.329663916291632002e-19 6.070000000000000000e+03 6.969032111291268370e-19 6.072000000000000000e+03 7.559505806342424545e-19 6.074000000000000000e+03 7.650022968492221821e-19 6.076000000000000000e+03 6.325015244416971295e-19 6.078000000000000000e+03 6.069756178471011778e-19 6.080000000000000000e+03 6.065421741051056421e-19 6.082000000000000000e+03 6.069187933164878111e-19 6.084000000000000000e+03 6.066104878814020520e-19 6.086000000000000000e+03 6.104676885162816732e-19 6.088000000000000000e+03 6.378393695634451112e-19 6.090000000000000000e+03 6.827495324418377441e-19 6.092000000000000000e+03 6.622447626653696818e-19 6.094000000000000000e+03 7.144735491159798410e-19 6.096000000000000000e+03 6.528206552397438015e-19 6.098000000000000000e+03 6.088449971165838481e-19 6.100000000000000000e+03 6.048418523778333374e-19 6.102000000000000000e+03 6.087840355813079511e-19 6.104000000000000000e+03 6.081112794606988911e-19 6.106000000000000000e+03 6.078600695032219863e-19 6.108000000000000000e+03 6.087782234845761560e-19 6.110000000000000000e+03 6.090609896573501837e-19 6.112000000000000000e+03 6.108590853421991852e-19 6.114000000000000000e+03 6.285076391776854277e-19 6.116000000000000000e+03 6.216070936212239297e-19 6.118000000000000000e+03 6.120346981365033759e-19 6.120000000000000000e+03 6.334004988910707064e-19 6.122000000000000000e+03 6.316353353144856864e-19 6.124000000000000000e+03 6.125743056705174496e-19 6.126000000000000000e+03 6.133588713086072417e-19 6.128000000000000000e+03 6.160699486758918032e-19 6.130000000000000000e+03 6.150156565937534720e-19 6.132000000000000000e+03 6.138657408237962579e-19 6.134000000000000000e+03 6.119509872198920613e-19 6.136000000000000000e+03 6.101974308669117422e-19 6.138000000000000000e+03 6.105154027880489484e-19 6.140000000000000000e+03 6.121234750613440279e-19 6.142000000000000000e+03 6.123583983996275411e-19 6.144000000000000000e+03 6.134567402219270196e-19 6.146000000000000000e+03 6.105791356455988882e-19 6.148000000000000000e+03 6.185111726558406912e-19 6.150000000000000000e+03 6.412325491022225980e-19 6.152000000000000000e+03 6.196173003743176097e-19 6.154000000000000000e+03 6.114739876589779176e-19 6.156000000000000000e+03 6.115442358758259092e-19 6.158000000000000000e+03 6.150086999418373501e-19 6.160000000000000000e+03 6.145851910238077647e-19 6.162000000000000000e+03 6.137078743599010673e-19 6.164000000000000000e+03 6.436829156483643202e-19 6.166000000000000000e+03 7.428324672476419439e-19 6.168000000000000000e+03 6.765348082208771494e-19 6.170000000000000000e+03 6.268277143175580390e-19 6.172000000000000000e+03 6.222271776167697911e-19 6.174000000000000000e+03 6.132471207112169504e-19 6.176000000000000000e+03 6.148548138008989505e-19 6.178000000000000000e+03 6.203172382024284295e-19 6.180000000000000000e+03 6.423532868357498513e-19 6.182000000000000000e+03 6.277208970795197976e-19 6.184000000000000000e+03 6.188473500393028451e-19 6.186000000000000000e+03 6.177344716877478344e-19 6.188000000000000000e+03 6.153587470420889292e-19 6.190000000000000000e+03 6.194695083681233528e-19 6.192000000000000000e+03 6.193765666081935910e-19 6.194000000000000000e+03 6.176252180061166428e-19 6.196000000000000000e+03 6.183893494154649489e-19 6.198000000000000000e+03 6.169723995516149887e-19 6.200000000000000000e+03 6.180367516104634613e-19 6.202000000000000000e+03 6.187047841566801625e-19 6.204000000000000000e+03 6.169918719302981926e-19 6.206000000000000000e+03 6.182618956659953468e-19 6.208000000000000000e+03 6.185254985176768132e-19 6.210000000000000000e+03 6.196035146062537439e-19 6.212000000000000000e+03 6.425120618730864362e-19 6.214000000000000000e+03 6.441146708406430598e-19 6.216000000000000000e+03 6.203080672030943435e-19 6.218000000000000000e+03 6.200283941695971275e-19 6.220000000000000000e+03 6.201702900083907904e-19 6.222000000000000000e+03 6.204651893573212324e-19 6.224000000000000000e+03 6.196363323284452065e-19 6.226000000000000000e+03 6.210419487705052952e-19 6.228000000000000000e+03 6.227852958997724388e-19 6.230000000000000000e+03 6.282370385661279489e-19 6.232000000000000000e+03 6.536089470471072548e-19 6.234000000000000000e+03 6.369634430607352135e-19 6.236000000000000000e+03 6.227799061000725240e-19 6.238000000000000000e+03 6.332793237216524189e-19 6.240000000000000000e+03 6.591413955914178531e-19 6.242000000000000000e+03 6.313479555234281387e-19 6.244000000000000000e+03 6.222097050678423593e-19 6.246000000000000000e+03 6.233464786836876924e-19 6.248000000000000000e+03 6.248897089561693776e-19 6.250000000000000000e+03 6.236568366360659637e-19 6.252000000000000000e+03 6.277318146063770729e-19 6.254000000000000000e+03 6.272829574830661085e-19 6.256000000000000000e+03 6.267911282587787255e-19 6.258000000000000000e+03 6.256407979055711409e-19 6.260000000000000000e+03 6.257265114634871236e-19 6.262000000000000000e+03 6.268427368249736706e-19 6.264000000000000000e+03 6.260289309302144356e-19 6.266000000000000000e+03 6.268580405895865095e-19 6.268000000000000000e+03 6.263166324242870477e-19 6.270000000000000000e+03 6.242726774432948310e-19 6.272000000000000000e+03 6.271455492488798746e-19 6.274000000000000000e+03 6.268312438669222815e-19 6.276000000000000000e+03 6.261270803772187631e-19 6.278000000000000000e+03 6.287915097198591121e-19 6.280000000000000000e+03 6.296784795761533194e-19 6.282000000000000000e+03 6.308373063333024438e-19 6.284000000000000000e+03 6.298551016300962794e-19 6.286000000000000000e+03 6.301431566419901968e-19 6.288000000000000000e+03 6.338915787150952551e-19 6.290000000000000000e+03 6.323296270883595818e-19 6.292000000000000000e+03 6.322338204855376906e-19 6.294000000000000000e+03 6.332957637111778998e-19 6.296000000000000000e+03 6.369135900268081350e-19 6.298000000000000000e+03 6.427756588843225610e-19 6.300000000000000000e+03 6.521706146267221258e-19 6.302000000000000000e+03 6.449957160456566042e-19 6.304000000000000000e+03 6.382424645176912564e-19 6.306000000000000000e+03 6.405132213229407448e-19 6.308000000000000000e+03 6.460787647611363184e-19 6.310000000000000000e+03 6.537496165949221894e-19 6.312000000000000000e+03 6.485179077989424744e-19 6.314000000000000000e+03 6.426849661096641836e-19 6.316000000000000000e+03 6.416616882158843817e-19 6.318000000000000000e+03 6.446672648104483890e-19 6.320000000000000000e+03 6.459530727712187464e-19 6.322000000000000000e+03 6.516456808159112550e-19 6.324000000000000000e+03 6.550168351031573279e-19 6.326000000000000000e+03 6.663146835295610130e-19 6.328000000000000000e+03 6.842752040988803602e-19 6.330000000000000000e+03 7.240021167243517156e-19 6.332000000000000000e+03 7.922617540622501182e-19 6.334000000000000000e+03 8.754682941788594030e-19 6.336000000000000000e+03 8.852872471368481068e-19 6.338000000000000000e+03 8.161610085234000007e-19 6.340000000000000000e+03 7.386800434108984267e-19 6.342000000000000000e+03 6.989324329420403151e-19 6.344000000000000000e+03 6.795539546314868598e-19 6.346000000000000000e+03 6.668062471577945546e-19 6.348000000000000000e+03 6.560758560610543978e-19 6.350000000000000000e+03 6.524281659345587230e-19 6.352000000000000000e+03 6.508186167050071086e-19 6.354000000000000000e+03 6.460228913902940618e-19 6.356000000000000000e+03 6.447576676905338038e-19 6.358000000000000000e+03 6.455503698449530804e-19 6.360000000000000000e+03 6.444404235236863563e-19 6.362000000000000000e+03 6.452591812530714827e-19 6.364000000000000000e+03 6.416257609855731241e-19 6.366000000000000000e+03 6.406824285802961954e-19 6.368000000000000000e+03 6.392889367494134354e-19 6.370000000000000000e+03 6.423152532851390286e-19 6.372000000000000000e+03 6.438051010486812664e-19 6.374000000000000000e+03 6.419509693333699961e-19 6.376000000000000000e+03 6.425765514638945181e-19 6.378000000000000000e+03 6.447622987115301235e-19 6.380000000000000000e+03 6.439905274143223060e-19 6.382000000000000000e+03 6.429613782496777827e-19 6.384000000000000000e+03 6.440603158373959728e-19 6.386000000000000000e+03 6.430101548421437355e-19 6.388000000000000000e+03 6.432681148205332330e-19 6.390000000000000000e+03 6.463288216655700099e-19 6.392000000000000000e+03 6.448324526542814414e-19 6.394000000000000000e+03 6.437631266507110780e-19 6.396000000000000000e+03 6.446860062632467868e-19 6.398000000000000000e+03 6.444285820393654175e-19 6.400000000000000000e+03 6.465168845477598862e-19 6.402000000000000000e+03 6.456544764659875592e-19 6.404000000000000000e+03 6.455152584921488141e-19 6.406000000000000000e+03 6.479961371210624573e-19 6.408000000000000000e+03 6.498508669126041718e-19 6.410000000000000000e+03 6.445899352966997661e-19 6.412000000000000000e+03 6.437059437394092225e-19 6.414000000000000000e+03 6.462586621436995104e-19 6.416000000000000000e+03 6.463417109089717026e-19 6.418000000000000000e+03 6.457880900333893597e-19 6.420000000000000000e+03 6.480189189628811817e-19 6.422000000000000000e+03 6.472663005435704615e-19 6.424000000000000000e+03 6.468178293321054669e-19 6.426000000000000000e+03 6.504365940306827385e-19 6.428000000000000000e+03 6.490251919767395156e-19 6.430000000000000000e+03 6.496423660567536476e-19 6.432000000000000000e+03 6.470772656286091531e-19 6.434000000000000000e+03 6.466642143738262763e-19 6.436000000000000000e+03 6.478159110159269620e-19 6.438000000000000000e+03 6.492052871081553781e-19 6.440000000000000000e+03 6.482096456306181545e-19 6.442000000000000000e+03 6.493158301293002563e-19 6.444000000000000000e+03 6.488812187527137719e-19 6.446000000000000000e+03 6.478959187259101938e-19 6.448000000000000000e+03 6.505974581919878750e-19 6.450000000000000000e+03 6.527683014257456343e-19 6.452000000000000000e+03 6.497073632173066426e-19 6.454000000000000000e+03 6.537590470161758419e-19 6.456000000000000000e+03 6.516228407189745663e-19 6.458000000000000000e+03 6.519009753855656470e-19 6.460000000000000000e+03 6.543368686740675497e-19 6.462000000000000000e+03 6.552294134838143737e-19 6.464000000000000000e+03 6.542628352373847765e-19 6.466000000000000000e+03 6.547500600703474027e-19 6.468000000000000000e+03 6.545023698922594517e-19 6.470000000000000000e+03 6.546181694481155794e-19 6.472000000000000000e+03 6.535090249781809216e-19 6.474000000000000000e+03 6.550616845659235443e-19 6.476000000000000000e+03 6.562650554290471419e-19 6.478000000000000000e+03 6.549935551204018525e-19 6.480000000000000000e+03 6.566514426991607047e-19 6.482000000000000000e+03 6.564431462579035516e-19 6.484000000000000000e+03 6.571107977838602599e-19 6.486000000000000000e+03 6.561852556486500672e-19 6.488000000000000000e+03 6.568172776223114539e-19 6.490000000000000000e+03 6.565043178703007532e-19 6.492000000000000000e+03 6.557625129905290346e-19 6.494000000000000000e+03 6.580096362714375001e-19 6.496000000000000000e+03 7.281991880936514542e-19 6.498000000000000000e+03 8.340840202029075360e-19 6.500000000000000000e+03 6.908868859199781726e-19 6.502000000000000000e+03 6.614312248468184187e-19 6.504000000000000000e+03 6.794810422309913632e-19 6.506000000000000000e+03 7.687423960957680335e-19 6.508000000000000000e+03 7.300427755310551532e-19 6.510000000000000000e+03 6.809590428428032668e-19 6.512000000000000000e+03 6.671554752066173793e-19 6.514000000000000000e+03 6.755192255849717741e-19 6.516000000000000000e+03 6.891550308107463276e-19 6.518000000000000000e+03 6.704850348280860137e-19 6.520000000000000000e+03 6.661074196462021410e-19 6.522000000000000000e+03 6.636267481864060978e-19 6.524000000000000000e+03 6.621113657358521639e-19 6.526000000000000000e+03 6.626740012149702353e-19 6.528000000000000000e+03 6.615179845600320461e-19 6.530000000000000000e+03 6.596985248328049279e-19 6.532000000000000000e+03 6.664066267368884755e-19 6.534000000000000000e+03 6.738370159692539957e-19 6.536000000000000000e+03 6.740424835280862435e-19 6.538000000000000000e+03 6.731057719401304570e-19 6.540000000000000000e+03 6.741737745818536054e-19 6.542000000000000000e+03 6.733674958528696202e-19 6.544000000000000000e+03 6.805882137763915423e-19 6.546000000000000000e+03 6.729368346890202572e-19 6.548000000000000000e+03 7.517908118087831416e-19 6.550000000000000000e+03 7.389315665951786732e-19 6.552000000000000000e+03 6.720977679350591061e-19 6.554000000000000000e+03 6.699239059685011920e-19 6.556000000000000000e+03 7.594398567467436359e-19 6.558000000000000000e+03 8.675033654520153848e-19 6.560000000000000000e+03 7.054753053680855848e-19 6.562000000000000000e+03 6.707463010897905303e-19 6.564000000000000000e+03 6.676254391546454930e-19 6.566000000000000000e+03 6.688568559051767286e-19 6.568000000000000000e+03 6.751062930559306635e-19 6.570000000000000000e+03 8.219539177991933364e-19 6.572000000000000000e+03 9.373199799613655637e-19 6.574000000000000000e+03 8.771888244722178366e-19 6.576000000000000000e+03 7.145298481312987548e-19 6.578000000000000000e+03 6.834944922212666489e-19 6.580000000000000000e+03 6.763920896138475029e-19 6.582000000000000000e+03 6.732105866679385223e-19 6.584000000000000000e+03 6.742318311770224654e-19 6.586000000000000000e+03 6.716644285312609541e-19 6.588000000000000000e+03 6.730342510999890499e-19 6.590000000000000000e+03 6.732028327067332184e-19 6.592000000000000000e+03 6.741724741098695352e-19 6.594000000000000000e+03 6.723036033404624451e-19 6.596000000000000000e+03 6.729485707661546635e-19 6.598000000000000000e+03 6.766809718667703958e-19 6.600000000000000000e+03 6.965876930995725160e-19 6.602000000000000000e+03 6.839060881109698926e-19 6.604000000000000000e+03 6.758956820632556590e-19 6.606000000000000000e+03 6.793023168544965448e-19 6.608000000000000000e+03 6.780547436556123790e-19 6.610000000000000000e+03 6.770840603339383909e-19 6.612000000000000000e+03 6.750967449140834753e-19 6.614000000000000000e+03 6.754344335806482318e-19 6.616000000000000000e+03 6.756422653633307245e-19 6.618000000000000000e+03 6.809725280808098160e-19 6.620000000000000000e+03 6.924573696993310792e-19 6.622000000000000000e+03 6.880873716843924071e-19 6.624000000000000000e+03 6.856384591512050078e-19 6.626000000000000000e+03 6.865054634595523373e-19 6.628000000000000000e+03 6.855351075289931707e-19 6.630000000000000000e+03 6.856005344487334380e-19 6.632000000000000000e+03 6.830145797409769232e-19 6.634000000000000000e+03 6.817992471046107367e-19 6.636000000000000000e+03 6.823717604000540043e-19 6.638000000000000000e+03 6.899985284172431312e-19 6.640000000000000000e+03 7.023722089656691654e-19 6.642000000000000000e+03 6.873676965389120987e-19 6.644000000000000000e+03 6.822090380821449862e-19 6.646000000000000000e+03 6.913834240820781751e-19 6.648000000000000000e+03 7.010325118875999644e-19 6.650000000000000000e+03 6.907698931471150443e-19 6.652000000000000000e+03 6.849793834917691643e-19 6.654000000000000000e+03 6.850385488100169132e-19 6.656000000000000000e+03 6.869754418647722383e-19 6.658000000000000000e+03 6.858150359764954276e-19 6.660000000000000000e+03 6.853080225807728337e-19 6.662000000000000000e+03 6.899249965964534708e-19 6.664000000000000000e+03 6.912049637107442689e-19 6.666000000000000000e+03 6.974810638595255481e-19 6.668000000000000000e+03 6.946992002332101972e-19 6.670000000000000000e+03 6.892418628643371971e-19 6.672000000000000000e+03 6.897460419876188173e-19 6.674000000000000000e+03 6.888032137576114895e-19 6.676000000000000000e+03 6.913197404285344701e-19 6.678000000000000000e+03 6.935969854658124536e-19 6.680000000000000000e+03 6.932414794769817461e-19 6.682000000000000000e+03 6.917879855906002923e-19 6.684000000000000000e+03 6.971754702023941553e-19 6.686000000000000000e+03 6.969434846817965524e-19 6.688000000000000000e+03 7.042909303268701421e-19 6.690000000000000000e+03 7.291283218095199920e-19 6.692000000000000000e+03 7.239725954328819220e-19 6.694000000000000000e+03 7.016977817403820788e-19 6.696000000000000000e+03 6.969139334232671436e-19 6.698000000000000000e+03 6.975609137079368529e-19 6.700000000000000000e+03 7.039957848162045715e-19 6.702000000000000000e+03 7.165761974855582788e-19 6.704000000000000000e+03 7.529283844297408617e-19 6.706000000000000000e+03 7.492970862429087671e-19 6.708000000000000000e+03 7.178553206115737732e-19 6.710000000000000000e+03 7.044897214347747012e-19 6.712000000000000000e+03 6.990800066923334987e-19 6.714000000000000000e+03 7.005173097298327638e-19 6.716000000000000000e+03 7.002294906611872541e-19 6.718000000000000000e+03 7.024791068715685834e-19 6.720000000000000000e+03 7.029556646158849859e-19 6.722000000000000000e+03 7.028845674036303172e-19 6.724000000000000000e+03 7.026395228513422316e-19 6.726000000000000000e+03 7.016599279030594065e-19 6.728000000000000000e+03 7.030549070958665537e-19 6.730000000000000000e+03 7.046652215426052342e-19 6.732000000000000000e+03 7.039052654817759297e-19 6.734000000000000000e+03 7.037405459719008063e-19 6.736000000000000000e+03 7.055112276162167582e-19 6.738000000000000000e+03 7.074299923627490512e-19 6.740000000000000000e+03 7.090352545924837328e-19 6.742000000000000000e+03 7.078385009687843455e-19 6.744000000000000000e+03 7.076703521956444047e-19 6.746000000000000000e+03 7.058453206742735357e-19 6.748000000000000000e+03 7.071687931276589562e-19 6.750000000000000000e+03 7.082972601294900878e-19 6.752000000000000000e+03 7.073377531387764746e-19 6.754000000000000000e+03 7.090800976363900673e-19 6.756000000000000000e+03 7.091140918651239975e-19 6.758000000000000000e+03 7.116204496145259156e-19 6.760000000000000000e+03 7.102435383378358512e-19 6.762000000000000000e+03 7.080680383144741318e-19 6.764000000000000000e+03 7.111031944073531369e-19 6.766000000000000000e+03 7.132584358075322091e-19 6.768000000000000000e+03 7.119442924674460172e-19 6.770000000000000000e+03 7.146432772988267827e-19 6.772000000000000000e+03 7.159382816757281844e-19 6.774000000000000000e+03 7.159570893208653225e-19 6.776000000000000000e+03 7.192161070548673462e-19 6.778000000000000000e+03 7.177294879563272728e-19 6.780000000000000000e+03 7.188835690962776238e-19 6.782000000000000000e+03 7.203553162565678510e-19 6.784000000000000000e+03 7.209319348076799008e-19 6.786000000000000000e+03 7.218079183835863190e-19 6.788000000000000000e+03 7.217981693099710858e-19 6.790000000000000000e+03 7.189617133447225201e-19 6.792000000000000000e+03 7.207936250447085194e-19 6.794000000000000000e+03 7.226517860360347215e-19 6.796000000000000000e+03 7.240246565118945112e-19 6.798000000000000000e+03 7.264267156003696510e-19 6.800000000000000000e+03 7.220128942197114370e-19 6.802000000000000000e+03 7.212968739382549000e-19 6.804000000000000000e+03 7.196633205105984279e-19 6.806000000000000000e+03 7.248656016424097625e-19 6.808000000000000000e+03 7.278731132898020734e-19 6.810000000000000000e+03 7.254694891149609369e-19 6.812000000000000000e+03 7.268273252573555311e-19 6.814000000000000000e+03 7.271273350519255330e-19 6.816000000000000000e+03 7.268082020665119091e-19 6.818000000000000000e+03 7.278022976517126215e-19 6.820000000000000000e+03 7.308268113240867843e-19 6.822000000000000000e+03 7.307424917966489708e-19 6.824000000000000000e+03 7.329271010376771945e-19 6.826000000000000000e+03 7.317733305522426478e-19 6.828000000000000000e+03 7.336784495852831292e-19 6.830000000000000000e+03 7.359284262561990721e-19 6.832000000000000000e+03 7.347025080859743671e-19 6.834000000000000000e+03 7.347640076907817485e-19 6.836000000000000000e+03 7.382264109749109070e-19 6.838000000000000000e+03 7.374866162731739522e-19 6.840000000000000000e+03 7.404967680338061229e-19 6.842000000000000000e+03 7.391060928528892562e-19 6.844000000000000000e+03 7.400471931596501016e-19 6.846000000000000000e+03 7.410050723771334328e-19 6.848000000000000000e+03 7.423449873990077227e-19 6.850000000000000000e+03 7.433966222809640534e-19 6.852000000000000000e+03 7.441080431740274277e-19 6.854000000000000000e+03 7.440751925546365842e-19 6.856000000000000000e+03 7.463431394930214656e-19 6.858000000000000000e+03 7.440314308861367368e-19 6.860000000000000000e+03 7.446858855329360319e-19 6.862000000000000000e+03 7.473276695749014539e-19 6.864000000000000000e+03 7.488306893199925855e-19 6.866000000000000000e+03 7.490303509637594326e-19 6.868000000000000000e+03 7.485334914422074455e-19 6.870000000000000000e+03 7.514744878155479071e-19 6.872000000000000000e+03 7.506866530572104738e-19 6.874000000000000000e+03 7.504693246199192509e-19 6.876000000000000000e+03 7.527139623664075712e-19 6.878000000000000000e+03 7.534041156539315040e-19 6.880000000000000000e+03 7.537604259049176265e-19 6.882000000000000000e+03 7.551034377362409118e-19 6.884000000000000000e+03 7.541740090048014746e-19 6.886000000000000000e+03 7.575216621470755642e-19 6.888000000000000000e+03 7.581734861899950853e-19 6.890000000000000000e+03 7.568153652911318640e-19 6.892000000000000000e+03 7.611093309211672969e-19 6.894000000000000000e+03 7.595634947778855323e-19 6.896000000000000000e+03 7.621570615659144861e-19 6.898000000000000000e+03 7.643956818700440086e-19 6.900000000000000000e+03 7.662121476105811233e-19 6.902000000000000000e+03 7.658001270947425545e-19 6.904000000000000000e+03 7.674144267380728912e-19 6.906000000000000000e+03 7.714415212251577240e-19 6.908000000000000000e+03 7.696875489360194115e-19 6.910000000000000000e+03 7.706864818026464959e-19 6.912000000000000000e+03 7.722832642043146974e-19 6.914000000000000000e+03 7.703495515233872586e-19 6.916000000000000000e+03 7.734448131739300189e-19 6.918000000000000000e+03 7.746541638109320040e-19 6.920000000000000000e+03 7.754320603334582127e-19 6.922000000000000000e+03 7.772801455717910155e-19 6.924000000000000000e+03 7.752731695854051820e-19 6.926000000000000000e+03 7.783199666254928674e-19 6.928000000000000000e+03 7.826112121705417717e-19 6.930000000000000000e+03 7.812845010842816998e-19 6.932000000000000000e+03 7.833960725118684338e-19 6.934000000000000000e+03 7.831835023112302037e-19 6.936000000000000000e+03 7.835005260850504075e-19 6.938000000000000000e+03 7.851924955789952370e-19 6.940000000000000000e+03 7.824565948741381834e-19 6.942000000000000000e+03 7.841794795690908566e-19 6.944000000000000000e+03 7.872931425676231772e-19 6.946000000000000000e+03 7.912104453284816971e-19 6.948000000000000000e+03 7.887768131242893716e-19 6.950000000000000000e+03 7.922527074090114289e-19 6.952000000000000000e+03 7.966528591135864406e-19 6.954000000000000000e+03 7.949131240766987362e-19 6.956000000000000000e+03 7.965956379953359254e-19 6.958000000000000000e+03 7.950043661127129646e-19 6.960000000000000000e+03 7.956304515129461907e-19 6.962000000000000000e+03 7.992034713855126815e-19 6.964000000000000000e+03 7.985972933663893382e-19 6.966000000000000000e+03 8.016103783853197059e-19 6.968000000000000000e+03 8.023587093970015830e-19 6.970000000000000000e+03 8.031262359396029163e-19 6.972000000000000000e+03 8.057105895264282704e-19 6.974000000000000000e+03 8.048462408941586355e-19 6.976000000000000000e+03 8.069495068905242877e-19 6.978000000000000000e+03 8.085971264388081750e-19 6.980000000000000000e+03 8.097906357031248144e-19 6.982000000000000000e+03 8.108192342600831071e-19 6.984000000000000000e+03 8.153583877842045385e-19 6.986000000000000000e+03 8.198643964966543076e-19 6.988000000000000000e+03 8.272605596502730231e-19 6.990000000000000000e+03 8.289353800329557268e-19 6.992000000000000000e+03 8.181377046923582988e-19 6.994000000000000000e+03 8.213133500713413811e-19 6.996000000000000000e+03 8.232051792191781547e-19 6.998000000000000000e+03 1.002842507679106224e-18 7.000000000000000000e+03 1.356058980676018041e-18 7.002000000000000000e+03 9.376457023804335366e-19 7.004000000000000000e+03 8.304283056713046083e-19 7.006000000000000000e+03 8.296775896869104825e-19 7.008000000000000000e+03 8.376868120300010298e-19 7.010000000000000000e+03 8.381410554612321642e-19 7.012000000000000000e+03 8.419869357779356621e-19 7.014000000000000000e+03 8.459494076451630695e-19 7.016000000000000000e+03 8.397552275202584735e-19 7.018000000000000000e+03 8.483243291090187916e-19 7.020000000000000000e+03 8.670553460507668349e-19 7.022000000000000000e+03 8.458738369563467093e-19 7.024000000000000000e+03 8.460130775124026686e-19 7.026000000000000000e+03 8.458700054380435332e-19 7.028000000000000000e+03 8.570535084030620355e-19 7.030000000000000000e+03 8.596644627205662350e-19 7.032000000000000000e+03 8.690971787727674674e-19 7.034000000000000000e+03 8.912186402904426633e-19 7.036000000000000000e+03 9.072052036093978262e-19 7.038000000000000000e+03 8.829673573524456336e-19 7.040000000000000000e+03 8.775876885894373217e-19 7.042000000000000000e+03 8.819564098433511301e-19 7.044000000000000000e+03 8.761213371892043124e-19 7.046000000000000000e+03 8.839707081878360589e-19 7.048000000000000000e+03 9.860467477366591578e-19 7.050000000000000000e+03 9.289208827702756219e-19 7.052000000000000000e+03 8.684042392723589188e-19 7.054000000000000000e+03 8.683135908634906293e-19 7.056000000000000000e+03 8.734671010538355205e-19 7.058000000000000000e+03 8.827833496833680218e-19 7.060000000000000000e+03 9.361419916031101854e-19 7.062000000000000000e+03 1.017278448347840473e-18 7.064000000000000000e+03 9.220323751967857172e-19 7.066000000000000000e+03 8.859641244321947642e-19 7.068000000000000000e+03 8.954128406196785049e-19 7.070000000000000000e+03 8.845946027331192639e-19 7.072000000000000000e+03 8.818269082164572968e-19 7.074000000000000000e+03 8.840073759076755067e-19 7.076000000000000000e+03 8.883796318626927067e-19 7.078000000000000000e+03 8.888915512916078420e-19 7.080000000000000000e+03 9.032105234269221087e-19 7.082000000000000000e+03 9.264135869023784191e-19 7.084000000000000000e+03 9.159997953375498242e-19 7.086000000000000000e+03 9.094376951552219194e-19 7.088000000000000000e+03 9.017596629810592809e-19 7.090000000000000000e+03 8.987046389646294621e-19 7.092000000000000000e+03 8.994524189557399139e-19 7.094000000000000000e+03 9.036635340839910766e-19 7.096000000000000000e+03 9.063288454560851099e-19 7.098000000000000000e+03 9.078641696674129488e-19 7.100000000000000000e+03 9.104284536326055934e-19 7.102000000000000000e+03 9.142726725618554213e-19 7.104000000000000000e+03 9.176361673978521635e-19 7.106000000000000000e+03 9.127097354932816934e-19 7.108000000000000000e+03 9.182699171527855809e-19 7.110000000000000000e+03 9.244736599704276663e-19 7.112000000000000000e+03 9.204165148679905886e-19 7.114000000000000000e+03 9.310101292555187838e-19 7.116000000000000000e+03 9.331710217191783212e-19 7.118000000000000000e+03 9.295065508951665213e-19 7.120000000000000000e+03 9.292679405563858135e-19 7.122000000000000000e+03 9.539959487759589514e-19 7.124000000000000000e+03 9.554110210468882612e-19 7.126000000000000000e+03 9.347363244084522234e-19 7.128000000000000000e+03 9.369010217157600060e-19 7.130000000000000000e+03 9.375471704323341041e-19 7.132000000000000000e+03 9.463264238769322466e-19 7.134000000000000000e+03 9.594860471339355291e-19 7.136000000000000000e+03 9.490350673094598370e-19 7.138000000000000000e+03 9.458310548182523465e-19 7.140000000000000000e+03 9.493954944265078187e-19 7.142000000000000000e+03 9.480509647108368685e-19 7.144000000000000000e+03 9.496342415037305578e-19 7.146000000000000000e+03 9.547038410048095152e-19 7.148000000000000000e+03 9.570598025254302545e-19 7.150000000000000000e+03 9.630507645494696104e-19 7.152000000000000000e+03 9.601028068096798122e-19 7.154000000000000000e+03 9.590578593217256993e-19 7.156000000000000000e+03 9.621977084271001212e-19 7.158000000000000000e+03 9.648118851565501048e-19 7.160000000000000000e+03 9.797621339882859489e-19 7.162000000000000000e+03 9.840435675190989460e-19 7.164000000000000000e+03 9.691875883310517953e-19 7.166000000000000000e+03 9.742325737078593481e-19 7.168000000000000000e+03 9.775152076887464934e-19 7.170000000000000000e+03 9.769320052389157470e-19 7.172000000000000000e+03 9.789487944072821612e-19 7.174000000000000000e+03 9.792398779564905721e-19 7.176000000000000000e+03 9.809237090973227438e-19 7.178000000000000000e+03 9.837106538882183003e-19 7.180000000000000000e+03 9.890835997581234143e-19 7.182000000000000000e+03 9.903531670137668319e-19 7.184000000000000000e+03 9.901168375240361035e-19 7.186000000000000000e+03 9.922425381928910653e-19 7.188000000000000000e+03 9.919828737109838322e-19 7.190000000000000000e+03 9.932371020323511626e-19 7.192000000000000000e+03 1.002995265079125108e-18 7.194000000000000000e+03 1.005910191276709826e-18 7.196000000000000000e+03 1.003082350896714628e-18 7.198000000000000000e+03 1.005985355643456593e-18 7.200000000000000000e+03 1.005746557783573659e-18 7.202000000000000000e+03 1.005106311786552204e-18 7.204000000000000000e+03 1.005001307552291444e-18 7.206000000000000000e+03 1.012375883750112310e-18 7.208000000000000000e+03 1.013151655167582967e-18 7.210000000000000000e+03 1.016066082628203186e-18 7.212000000000000000e+03 1.017453820389906063e-18 7.214000000000000000e+03 1.019630115100870576e-18 7.216000000000000000e+03 1.019431002196433379e-18 7.218000000000000000e+03 1.017054861151407603e-18 7.220000000000000000e+03 1.022018254321383102e-18 7.222000000000000000e+03 1.023187019660203009e-18 7.224000000000000000e+03 1.022506377878636564e-18 7.226000000000000000e+03 1.026239263493160793e-18 7.228000000000000000e+03 1.027131892682547483e-18 7.230000000000000000e+03 1.022606718234158343e-18 7.232000000000000000e+03 1.030730941861066761e-18 7.234000000000000000e+03 1.033774032764856236e-18 7.236000000000000000e+03 1.033476232101305707e-18 7.238000000000000000e+03 1.031150630732305128e-18 7.240000000000000000e+03 1.033612974598341084e-18 7.242000000000000000e+03 1.040443850876237763e-18 7.244000000000000000e+03 1.037243883146562441e-18 7.246000000000000000e+03 1.039618106803839742e-18 7.248000000000000000e+03 1.042991505315683229e-18 7.250000000000000000e+03 1.045670286474693824e-18 7.252000000000000000e+03 1.046898227934644969e-18 7.254000000000000000e+03 1.046834114466454528e-18 7.256000000000000000e+03 1.045758535738350198e-18 7.258000000000000000e+03 1.047888580060684819e-18 7.260000000000000000e+03 1.050507933451559663e-18 7.262000000000000000e+03 1.048856720391915128e-18 7.264000000000000000e+03 1.050771772500932231e-18 7.266000000000000000e+03 1.051661068584577566e-18 7.268000000000000000e+03 1.053977068000493539e-18 7.270000000000000000e+03 1.052169179718672559e-18 7.272000000000000000e+03 1.053135568929237828e-18 7.274000000000000000e+03 1.056966900959842789e-18 7.276000000000000000e+03 1.056750309181941758e-18 7.278000000000000000e+03 1.054673717481169363e-18 7.280000000000000000e+03 1.063709817602437361e-18 7.282000000000000000e+03 1.178021423208058339e-18 7.284000000000000000e+03 1.250240048909880160e-18 7.286000000000000000e+03 1.108215633583286478e-18 7.288000000000000000e+03 1.068721902822396754e-18 7.290000000000000000e+03 1.067732178027813434e-18 7.292000000000000000e+03 1.062481849546311967e-18 7.294000000000000000e+03 1.064325082069712729e-18 7.296000000000000000e+03 1.064123748552379518e-18 7.298000000000000000e+03 1.064907945161287581e-18 7.300000000000000000e+03 1.060124389873396023e-18 7.302000000000000000e+03 1.061908043636070209e-18 7.304000000000000000e+03 1.058382019191573167e-18 7.306000000000000000e+03 1.061566376579886984e-18 7.308000000000000000e+03 1.059813484129761494e-18 7.310000000000000000e+03 1.060315293042896564e-18 7.312000000000000000e+03 1.065609185128942172e-18 7.314000000000000000e+03 1.065096782886564652e-18 7.316000000000000000e+03 1.064680491366063658e-18 7.318000000000000000e+03 1.064554137002890723e-18 7.320000000000000000e+03 1.062445098149044237e-18 7.322000000000000000e+03 1.060336435564335135e-18 7.324000000000000000e+03 1.063945825719138876e-18 7.326000000000000000e+03 1.063958626975117094e-18 7.328000000000000000e+03 1.065792640741497960e-18 7.330000000000000000e+03 1.062990121367946161e-18 7.332000000000000000e+03 1.066740307541868749e-18 7.334000000000000000e+03 1.067130901856392455e-18 7.336000000000000000e+03 1.062009411139657151e-18 7.338000000000000000e+03 1.061814462702388556e-18 7.340000000000000000e+03 1.062597217237124243e-18 7.342000000000000000e+03 1.059073333254484796e-18 7.344000000000000000e+03 1.062437467539093677e-18 7.346000000000000000e+03 1.067495882778048340e-18 7.348000000000000000e+03 1.063239746808842224e-18 7.350000000000000000e+03 1.064029033131158441e-18 7.352000000000000000e+03 1.064566960075521202e-18 7.354000000000000000e+03 1.061539885352793544e-18 7.356000000000000000e+03 1.062041952685657023e-18 7.358000000000000000e+03 1.063291145398700645e-18 7.360000000000000000e+03 1.063047894831397873e-18 7.362000000000000000e+03 1.059990626800422382e-18 7.364000000000000000e+03 1.062699003505454274e-18 7.366000000000000000e+03 1.064522025471312952e-18 7.368000000000000000e+03 1.061415565966371723e-18 7.370000000000000000e+03 1.061313051116564348e-18 7.372000000000000000e+03 1.057842080824950365e-18 7.374000000000000000e+03 1.058065325637342716e-18 7.376000000000000000e+03 1.066909696034473000e-18 7.378000000000000000e+03 1.094211785101037516e-18 7.380000000000000000e+03 1.125402139087230872e-18 7.382000000000000000e+03 1.076806682048040181e-18 7.384000000000000000e+03 1.057967031693175391e-18 7.386000000000000000e+03 1.057617571244106610e-18 7.388000000000000000e+03 1.053907454576477179e-18 7.390000000000000000e+03 1.054716827480250225e-18 7.392000000000000000e+03 1.055430632965742217e-18 7.394000000000000000e+03 1.054582531095036656e-18 7.396000000000000000e+03 1.056194353911030192e-18 7.398000000000000000e+03 1.202636790473171867e-18 7.400000000000000000e+03 1.253161514385728444e-18 7.402000000000000000e+03 1.074953220752631382e-18 7.404000000000000000e+03 1.049934036609311345e-18 7.406000000000000000e+03 1.047879886619999739e-18 7.408000000000000000e+03 1.052272093603532329e-18 7.410000000000000000e+03 1.047439049088215799e-18 7.412000000000000000e+03 1.039707760729223422e-18 7.414000000000000000e+03 1.042192473058587143e-18 7.416000000000000000e+03 1.044594114233364237e-18 7.418000000000000000e+03 1.046252390265094761e-18 7.420000000000000000e+03 1.048899842487230799e-18 7.422000000000000000e+03 1.046664756008220856e-18 7.424000000000000000e+03 1.045616002349088853e-18 7.426000000000000000e+03 1.043536549957518015e-18 7.428000000000000000e+03 1.044561039634218637e-18 7.430000000000000000e+03 1.045133298868190759e-18 7.432000000000000000e+03 1.043178671511649002e-18 7.434000000000000000e+03 1.041450077175664582e-18 7.436000000000000000e+03 1.043119672655567526e-18 7.438000000000000000e+03 1.043773991932664808e-18 7.440000000000000000e+03 1.043495141428687737e-18 7.442000000000000000e+03 1.041070787797208528e-18 7.444000000000000000e+03 1.040615340158732921e-18 7.446000000000000000e+03 1.041280838667849187e-18 7.448000000000000000e+03 1.038364143321669874e-18 7.450000000000000000e+03 1.039837719215481546e-18 7.452000000000000000e+03 1.060740742583847571e-18 7.454000000000000000e+03 1.058233366662378447e-18 7.456000000000000000e+03 1.039555573454759308e-18 7.458000000000000000e+03 1.038993122471795270e-18 7.460000000000000000e+03 1.040808415886431951e-18 7.462000000000000000e+03 1.040422706932855647e-18 7.464000000000000000e+03 1.037356901767808336e-18 7.466000000000000000e+03 1.041187236068298832e-18 7.468000000000000000e+03 1.042238459020079217e-18 7.470000000000000000e+03 1.039322579207532007e-18 7.472000000000000000e+03 1.037685685524557892e-18 7.474000000000000000e+03 1.042002909245567649e-18 7.476000000000000000e+03 1.043525945700685031e-18 7.478000000000000000e+03 1.046480800325044350e-18 7.480000000000000000e+03 1.056077393406691200e-18 7.482000000000000000e+03 1.050070373771571123e-18 7.484000000000000000e+03 1.044328212872657640e-18 7.486000000000000000e+03 1.045835702138152512e-18 7.488000000000000000e+03 1.048705747309131452e-18 7.490000000000000000e+03 1.048552511908467647e-18 7.492000000000000000e+03 1.056822027840865100e-18 7.494000000000000000e+03 1.071750426289700838e-18 7.496000000000000000e+03 1.065339059072825885e-18 7.498000000000000000e+03 1.060747819114085360e-18 7.500000000000000000e+03 1.049710872628271175e-18 7.502000000000000000e+03 1.048422826242077800e-18 7.504000000000000000e+03 1.047683794557666402e-18 7.506000000000000000e+03 1.047550825586431806e-18 7.508000000000000000e+03 1.067152523212507613e-18 7.510000000000000000e+03 1.078026683204040439e-18 7.512000000000000000e+03 1.049707673066579764e-18 7.514000000000000000e+03 1.054608117444354034e-18 7.516000000000000000e+03 1.052693890105581136e-18 7.518000000000000000e+03 1.056000627748370871e-18 7.520000000000000000e+03 1.053442191030860357e-18 7.522000000000000000e+03 1.051964321347502280e-18 7.524000000000000000e+03 1.052323381160825644e-18 7.526000000000000000e+03 1.054865412987237917e-18 7.528000000000000000e+03 1.058628673742173610e-18 7.530000000000000000e+03 1.063802884587758835e-18 7.532000000000000000e+03 1.075126400422222680e-18 7.534000000000000000e+03 1.056462811799017039e-18 7.536000000000000000e+03 1.055392390325510351e-18 7.538000000000000000e+03 1.057731071418441268e-18 7.540000000000000000e+03 1.060539437794919161e-18 7.542000000000000000e+03 1.063017130955634792e-18 7.544000000000000000e+03 1.062102947932329488e-18 7.546000000000000000e+03 1.061455535750287268e-18 7.548000000000000000e+03 1.064089507030243364e-18 7.550000000000000000e+03 1.061886374601504887e-18 7.552000000000000000e+03 1.060227136375528519e-18 7.554000000000000000e+03 1.065347034574226567e-18 7.556000000000000000e+03 1.064499642753946365e-18 7.558000000000000000e+03 1.066204562956341535e-18 7.560000000000000000e+03 1.075408334706453510e-18 7.562000000000000000e+03 1.122673030473534117e-18 7.564000000000000000e+03 1.091148946494329735e-18 7.566000000000000000e+03 1.074799227882661573e-18 7.568000000000000000e+03 1.093530346071836973e-18 7.570000000000000000e+03 1.081006452449372625e-18 7.572000000000000000e+03 1.077819321840392441e-18 7.574000000000000000e+03 1.072822605863504315e-18 7.576000000000000000e+03 1.074097086497419444e-18 7.578000000000000000e+03 1.081865579935543123e-18 7.580000000000000000e+03 1.078796332632062101e-18 7.582000000000000000e+03 1.081935282496379200e-18 7.584000000000000000e+03 1.082034285223926842e-18 7.586000000000000000e+03 1.089998184756324049e-18 7.588000000000000000e+03 1.104118750677500610e-18 7.590000000000000000e+03 1.092752882393062236e-18 7.592000000000000000e+03 1.091643371600991186e-18 7.594000000000000000e+03 1.094439313742012672e-18 7.596000000000000000e+03 1.132331065167488361e-18 7.598000000000000000e+03 1.116114882661620717e-18 7.600000000000000000e+03 1.095413093363821844e-18 7.602000000000000000e+03 1.096537367482416877e-18 7.604000000000000000e+03 1.094664232292312499e-18 7.606000000000000000e+03 1.101165816721527115e-18 7.608000000000000000e+03 1.105782065379859527e-18 7.610000000000000000e+03 1.104015564428082816e-18 7.612000000000000000e+03 1.172328353918106700e-18 7.614000000000000000e+03 1.228347470239252995e-18 7.616000000000000000e+03 1.124135624405745449e-18 7.618000000000000000e+03 1.111461419780658798e-18 7.620000000000000000e+03 1.114720453262702821e-18 7.622000000000000000e+03 1.148403725384465288e-18 7.624000000000000000e+03 1.136663832020271553e-18 7.626000000000000000e+03 1.124954124905267012e-18 7.628000000000000000e+03 1.125296830885706297e-18 7.630000000000000000e+03 1.126760574660385166e-18 7.632000000000000000e+03 1.128721860097859097e-18 7.634000000000000000e+03 1.130706106820742015e-18 7.636000000000000000e+03 1.135209455759850281e-18 7.638000000000000000e+03 1.134840810403051454e-18 7.640000000000000000e+03 1.149370146016320296e-18 7.642000000000000000e+03 1.232483123615624362e-18 7.644000000000000000e+03 1.203703182876198001e-18 7.646000000000000000e+03 1.231735120218518913e-18 7.648000000000000000e+03 1.289345636878837972e-18 7.650000000000000000e+03 1.244127670216845708e-18 7.652000000000000000e+03 1.199338319526126896e-18 7.654000000000000000e+03 1.157387698926355008e-18 7.656000000000000000e+03 1.155490427112151798e-18 7.658000000000000000e+03 1.159634654088131751e-18 7.660000000000000000e+03 1.164478246857937424e-18 7.662000000000000000e+03 1.163580399168302918e-18 7.664000000000000000e+03 1.172912584459030933e-18 7.666000000000000000e+03 1.177612284789098323e-18 7.668000000000000000e+03 1.177418875076326550e-18 7.670000000000000000e+03 1.178364022695832613e-18 7.672000000000000000e+03 1.181291691207689529e-18 7.674000000000000000e+03 1.185445758020005885e-18 7.676000000000000000e+03 1.184680228724762232e-18 7.678000000000000000e+03 1.195675953157391962e-18 7.680000000000000000e+03 1.206593633516137145e-18 7.682000000000000000e+03 1.243430461936005130e-18 7.684000000000000000e+03 1.273750154383553781e-18 7.686000000000000000e+03 1.226504517140554928e-18 7.688000000000000000e+03 1.215406204737194012e-18 7.690000000000000000e+03 1.213802506947920134e-18 7.692000000000000000e+03 1.211787054951952596e-18 7.694000000000000000e+03 1.214884836101574457e-18 7.696000000000000000e+03 1.215665314588322331e-18 7.698000000000000000e+03 1.222070955822689537e-18 7.700000000000000000e+03 1.227538795632133970e-18 7.702000000000000000e+03 1.227839606853754635e-18 7.704000000000000000e+03 1.232717097659650383e-18 7.706000000000000000e+03 1.237522089878787319e-18 7.708000000000000000e+03 1.241837989190005155e-18 7.710000000000000000e+03 1.249678243118276954e-18 7.712000000000000000e+03 1.260375409817477236e-18 7.714000000000000000e+03 1.268701826253936464e-18 7.716000000000000000e+03 1.273540101452629534e-18 7.718000000000000000e+03 1.268811749729116205e-18 7.720000000000000000e+03 1.282804164078245561e-18 7.722000000000000000e+03 1.270200283125082791e-18 7.724000000000000000e+03 1.274690492675782465e-18 7.726000000000000000e+03 1.275317091135308540e-18 7.728000000000000000e+03 1.283434403862455512e-18 7.730000000000000000e+03 1.284977602409869855e-18 7.732000000000000000e+03 1.290331419483629244e-18 7.734000000000000000e+03 1.294926850777941083e-18 7.736000000000000000e+03 1.302327101624674766e-18 7.738000000000000000e+03 1.305156440399669513e-18 7.740000000000000000e+03 1.310633991628969325e-18 7.742000000000000000e+03 1.310611545993536823e-18 7.744000000000000000e+03 1.318281492512759492e-18 7.746000000000000000e+03 1.323645460416814604e-18 7.748000000000000000e+03 1.330486332109148670e-18 7.750000000000000000e+03 1.337220002874398018e-18 7.752000000000000000e+03 1.338069119780028507e-18 7.754000000000000000e+03 1.342397182059760016e-18 7.756000000000000000e+03 1.354304565246463129e-18 7.758000000000000000e+03 1.359706535594032936e-18 7.760000000000000000e+03 1.361851341967148612e-18 7.762000000000000000e+03 1.363012139160589275e-18 7.764000000000000000e+03 1.366766772762536523e-18 7.766000000000000000e+03 1.371339225097437388e-18 7.768000000000000000e+03 1.388759581055500777e-18 7.770000000000000000e+03 1.385035088548162122e-18 7.772000000000000000e+03 1.394578193698305116e-18 7.774000000000000000e+03 1.401821419508748391e-18 7.776000000000000000e+03 1.405053096716714494e-18 7.778000000000000000e+03 1.408446276597945244e-18 7.780000000000000000e+03 1.412336070483993434e-18 7.782000000000000000e+03 1.424353112539369297e-18 7.784000000000000000e+03 1.434424481177831793e-18 7.786000000000000000e+03 1.439735793293139658e-18 7.788000000000000000e+03 1.441690315862593577e-18 7.790000000000000000e+03 1.445620440921793738e-18 7.792000000000000000e+03 1.452247560358833374e-18 7.794000000000000000e+03 1.462527655532824276e-18 7.796000000000000000e+03 1.470879907291024497e-18 7.798000000000000000e+03 1.483299821860815739e-18 7.800000000000000000e+03 1.482330109170386133e-18 7.802000000000000000e+03 1.487429666864301717e-18 7.804000000000000000e+03 1.500899523375407028e-18 7.806000000000000000e+03 1.509802888876669405e-18 7.808000000000000000e+03 1.513663201308391197e-18 7.810000000000000000e+03 1.528314231330775026e-18 7.812000000000000000e+03 1.528449468345201844e-18 7.814000000000000000e+03 1.534024652778540004e-18 7.816000000000000000e+03 1.538247046053075261e-18 7.818000000000000000e+03 1.554866799092755046e-18 7.820000000000000000e+03 1.566302895501361748e-18 7.822000000000000000e+03 1.559226415903970765e-18 7.824000000000000000e+03 1.568638435898351485e-18 7.826000000000000000e+03 1.579281843691886701e-18 7.828000000000000000e+03 1.584100221598213835e-18 7.830000000000000000e+03 1.596783578717402183e-18 7.832000000000000000e+03 1.596586687065214084e-18 7.834000000000000000e+03 1.607110777703477129e-18 7.836000000000000000e+03 1.615786726389778891e-18 7.838000000000000000e+03 1.628158346196452956e-18 7.840000000000000000e+03 1.634349643609880376e-18 7.842000000000000000e+03 1.641788291762704578e-18 7.844000000000000000e+03 1.650162349808238292e-18 7.846000000000000000e+03 1.658017865283073581e-18 7.848000000000000000e+03 1.668637194047128136e-18 7.850000000000000000e+03 1.680260570879518311e-18 7.852000000000000000e+03 1.688373663016460396e-18 7.854000000000000000e+03 1.705160922040755904e-18 7.856000000000000000e+03 1.710999609466770811e-18 7.858000000000000000e+03 1.712616516938533326e-18 7.860000000000000000e+03 1.724364039989905845e-18 7.862000000000000000e+03 1.739093189189309814e-18 7.864000000000000000e+03 1.750803832844992496e-18 7.866000000000000000e+03 1.761188034965649874e-18 7.868000000000000000e+03 1.770308770310056867e-18 7.870000000000000000e+03 1.779725715069065397e-18 7.872000000000000000e+03 1.784316256388037274e-18 7.874000000000000000e+03 1.796556794452044751e-18 7.876000000000000000e+03 1.800988108700757533e-18 7.878000000000000000e+03 1.817859507759822023e-18 7.880000000000000000e+03 1.836475354000409166e-18 7.882000000000000000e+03 1.841713139958397758e-18 7.884000000000000000e+03 1.849772885431498638e-18 7.886000000000000000e+03 1.864498489043673761e-18 7.888000000000000000e+03 1.880337713087532300e-18 7.890000000000000000e+03 1.887048193140908141e-18 7.892000000000000000e+03 1.897553193539016664e-18 7.894000000000000000e+03 1.905941466115617815e-18 7.896000000000000000e+03 1.914744964894544843e-18 7.898000000000000000e+03 1.941315732229525138e-18 7.900000000000000000e+03 1.951891191447647130e-18 7.902000000000000000e+03 1.959575311512974935e-18 7.904000000000000000e+03 1.979417921368316458e-18 7.906000000000000000e+03 1.994264276068973244e-18 7.908000000000000000e+03 2.004069446971053420e-18 7.910000000000000000e+03 2.018471439474835148e-18 7.912000000000000000e+03 2.031813201784786736e-18 7.914000000000000000e+03 2.044251506548578355e-18 7.916000000000000000e+03 2.063062363794724167e-18 7.918000000000000000e+03 2.070738733226666701e-18 7.920000000000000000e+03 2.088849058752222408e-18 7.922000000000000000e+03 2.102684076826905967e-18 7.924000000000000000e+03 2.128176046948826563e-18 7.926000000000000000e+03 2.138515692983386953e-18 7.928000000000000000e+03 2.156129717790622952e-18 7.930000000000000000e+03 2.175640955072145666e-18 7.932000000000000000e+03 2.183367441988629220e-18 7.934000000000000000e+03 2.198084382540338903e-18 7.936000000000000000e+03 2.215493396660320711e-18 7.938000000000000000e+03 2.233780250204637781e-18 7.940000000000000000e+03 2.251633177216927601e-18 7.942000000000000000e+03 2.256705423845004586e-18 7.944000000000000000e+03 2.311800405776812245e-18 7.946000000000000000e+03 2.348204201787390084e-18 7.948000000000000000e+03 2.314550392614813108e-18 7.950000000000000000e+03 2.342255998688699932e-18 7.952000000000000000e+03 2.359386624284075717e-18 7.954000000000000000e+03 2.374618629672480169e-18 7.956000000000000000e+03 2.385571771814957023e-18 7.958000000000000000e+03 2.406897475495247720e-18 7.960000000000000000e+03 2.420458104772052718e-18 7.962000000000000000e+03 2.461164108324688441e-18 7.964000000000000000e+03 2.472568977250871159e-18 7.966000000000000000e+03 2.484200129587439535e-18 7.968000000000000000e+03 2.522409594581102754e-18 7.970000000000000000e+03 2.522184600491756011e-18 7.972000000000000000e+03 2.550773487705222394e-18 7.974000000000000000e+03 2.621343008466815080e-18 7.976000000000000000e+03 2.658262062811960280e-18 7.978000000000000000e+03 2.647374331249547185e-18 7.980000000000000000e+03 2.623859498240044088e-18 7.982000000000000000e+03 2.634279125219718079e-18 7.984000000000000000e+03 2.661756478160637767e-18 7.986000000000000000e+03 2.693204219984719520e-18 7.988000000000000000e+03 2.723415249490004079e-18 7.990000000000000000e+03 2.722173964808823370e-18 7.992000000000000000e+03 2.742250350503936605e-18 7.994000000000000000e+03 2.767539708510423789e-18 7.996000000000000000e+03 2.809869910702708890e-18 7.998000000000000000e+03 2.923880914628535999e-18 8.000000000000000000e+03 3.091551630320064565e-18 8.002000000000000000e+03 2.963045755550048573e-18 8.004000000000000000e+03 2.913418507054557798e-18 8.006000000000000000e+03 2.931529481398414497e-18 8.008000000000000000e+03 2.939420512959181560e-18 8.010000000000000000e+03 2.945923136786198543e-18 8.012000000000000000e+03 2.963065161173931648e-18 8.014000000000000000e+03 2.991603921396607014e-18 8.016000000000000000e+03 3.022285141209865394e-18 8.018000000000000000e+03 3.041455215044059355e-18 8.020000000000000000e+03 3.073902413802066180e-18 8.022000000000000000e+03 3.104264097389231707e-18 8.024000000000000000e+03 3.124885107287021976e-18 8.026000000000000000e+03 3.149671492728707667e-18 8.028000000000000000e+03 3.168464081503964708e-18 8.030000000000000000e+03 3.213362720611952121e-18 8.032000000000000000e+03 3.240177676923246028e-18 8.034000000000000000e+03 3.276135121097130156e-18 8.036000000000000000e+03 3.331141822334619551e-18 8.038000000000000000e+03 3.434324490119649930e-18 8.040000000000000000e+03 3.406846456264701187e-18 8.042000000000000000e+03 3.415322384275933714e-18 8.044000000000000000e+03 3.889793472624263230e-18 8.046000000000000000e+03 4.239314801896188756e-18 8.048000000000000000e+03 3.551392599364745551e-18 8.050000000000000000e+03 3.519697070069685288e-18 8.052000000000000000e+03 3.545287376371724076e-18 8.054000000000000000e+03 3.589574911434620475e-18 8.056000000000000000e+03 3.634091825605206814e-18 8.058000000000000000e+03 3.658888054407019726e-18 8.060000000000000000e+03 3.681512843161146010e-18 8.062000000000000000e+03 3.737105268854593839e-18 8.064000000000000000e+03 3.766293707680159390e-18 8.066000000000000000e+03 3.801174311357970311e-18 8.068000000000000000e+03 3.882282459743847735e-18 8.070000000000000000e+03 3.984846888538322049e-18 8.072000000000000000e+03 3.941678267944889826e-18 8.074000000000000000e+03 4.179689094257993751e-18 8.076000000000000000e+03 4.249562247705966719e-18 8.078000000000000000e+03 4.037925253477548762e-18 8.080000000000000000e+03 4.066140023177976003e-18 8.082000000000000000e+03 4.104990518620626536e-18 8.084000000000000000e+03 4.160433524203114275e-18 8.086000000000000000e+03 4.614807607039872640e-18 8.088000000000000000e+03 5.439720840085102662e-18 8.090000000000000000e+03 4.521393513532481049e-18 8.092000000000000000e+03 4.617481355293611257e-18 8.094000000000000000e+03 4.869683748566981220e-18 8.096000000000000000e+03 4.447442240446857173e-18 8.098000000000000000e+03 4.423913413277434162e-18 8.100000000000000000e+03 4.474125396378617866e-18 8.102000000000000000e+03 4.526686584394150399e-18 8.104000000000000000e+03 4.572670137496259786e-18 8.106000000000000000e+03 4.607645371826818603e-18 8.108000000000000000e+03 4.645316122746659142e-18 8.110000000000000000e+03 4.761982498510652026e-18 8.112000000000000000e+03 5.773435500398111325e-18 8.114000000000000000e+03 5.619063830334337447e-18 8.116000000000000000e+03 4.847040784034031182e-18 8.118000000000000000e+03 4.876365825306318191e-18 8.120000000000000000e+03 4.949760044612319732e-18 8.122000000000000000e+03 4.983474514908702884e-18 8.124000000000000000e+03 5.018703113454242126e-18 8.126000000000000000e+03 5.056327121952436826e-18 8.128000000000000000e+03 5.089708375145802447e-18 8.130000000000000000e+03 5.168919966620999926e-18 8.132000000000000000e+03 6.720937531921281554e-18 8.134000000000000000e+03 7.558710683188749354e-18 8.136000000000000000e+03 5.540687502369597999e-18 8.138000000000000000e+03 5.321081576208489303e-18 8.140000000000000000e+03 5.357222727574069162e-18 8.142000000000000000e+03 5.446069535143946029e-18 8.144000000000000000e+03 6.308063948115358915e-18 8.146000000000000000e+03 6.569581681702490634e-18 8.148000000000000000e+03 6.941898468351905026e-18 8.150000000000000000e+03 2.616617734087869392e-17 8.152000000000000000e+03 1.710799844744881930e-16 8.154000000000000000e+03 2.006073453781948122e-16 8.156000000000000000e+03 1.690573717420835292e-16 8.158000000000000000e+03 2.284654832250392159e-16 8.160000000000000000e+03 1.587097825813599180e-16 8.162000000000000000e+03 1.656782832381334520e-16 8.164000000000000000e+03 5.688083346157658668e-17 8.166000000000000000e+03 7.305135170098250935e-18 8.168000000000000000e+03 6.066508279396482797e-18 8.170000000000000000e+03 5.964732224974636150e-18 8.172000000000000000e+03 5.987879448448275265e-18 8.174000000000000000e+03 6.000754324025149718e-18 8.176000000000000000e+03 6.035271451754154323e-18 8.178000000000000000e+03 6.071633443564381558e-18 8.180000000000000000e+03 6.107073092773816242e-18 8.182000000000000000e+03 6.110803973872711344e-18 8.184000000000000000e+03 6.141317392317051874e-18 8.186000000000000000e+03 6.173863750907792778e-18 8.188000000000000000e+03 6.204465591878089105e-18 8.190000000000000000e+03 6.180608354159554082e-18 8.192000000000000000e+03 3.579935805863807840e-18