H1 SUS ITMY PUM Driver S1102654 /ligo/gitcommon/suspensions/ligo/electronics/fits/ fit_ITMY_PUM_driver_20220111.py no 2021-01-22 ~14:00 PST. The Answer: STATE 1 (ACQ OFF, LP OFF) SUMMARY UL -- [z]:[p] = [12.1728]:[113.5214] LL -- [z]:[p] = [12.2217]:[114.0444] UR -- [z]:[p] = [12.1865]:[113.624] LR -- [z]:[p] = [12.167]:[113.3223] STATE 2 (ACQ ON, LP OFF) SUMMARY UL -- [z]:[p] = [ 1.3605 3.2503 144.569 44618.5263]:[ 3.2453 76.3094 165.8424 34337.2341] LL -- [z]:[p] = [ 1.3603 1.8836 145.032 46343.9015]:[ 1.866 76.6325 166.5325 35320.1457] UR -- [z]:[p] = [ 1.3644 3.9862 144.7915 42212.5488]:[ 3.9812 76.1211 165.8732 32766.3716] LR -- [z]:[p] = [ 1.3814 8.3962 144.9408 43411.5415]:[ 8.3899 76.7451 166.784 33614.1043] STATE 3 (ACQ OFF, LP ON) SUMMARY UL -- [z]:[p] = [ 12.1946 27.5085 107.2517]:[ 2.4528 111.586 1219.6775] LL -- [z]:[p] = [ 12.2631 27.3909 107.1006]:[ 2.449 112.5326 1211.6746] UR -- [z]:[p] = [ 12.2127 27.5208 105.7357]:[ 2.4545 112.6425 1192.3429] LR -- [z]:[p] = [ 12.2265 27.838 106.9457]:[ 2.4953 112.9734 1196.3448] STATE3 / STATE 1 SUMMARY UL -- [z]:[p] = [ 26.3245 26.3246 109.4214]:[ 2.4481 25.2397 1221.3328] LL -- [z]:[p] = [ 27.4285 108.6187]:[ 2.4441 1213.0449] UR -- [z]:[p] = [ 27.5209 106.6734 717.1573]:[ 2.4495 713.9924 1198.7717] LR -- [z]:[p] = [ 26.4696 26.4698 107.4601]:[ 2.4908 25.1114 1198.0896]