H1 SUS ETMX PUM Driver S1000343 /ligo/gitcommon/suspensions/ligo/electronics/fits/ fit_ITMY_PUM_driver_20220114.py on 2021-01-17 ~13:00 PST. The Answer: STATE 1 (ACQ OFF, LP OFF) SUMMARY UL -- [z]:[p] = [12.1988]:[113.7677] LL -- [z]:[p] = [12.035]:[112.1194] UR -- [z]:[p] = [12.4062]:[115.6627] LR -- [z]:[p] = [12.2958]:[114.455] STATE 2 (ACQ ON, LP OFF) SUMMARY UL -- [z]:[p] = [ 1.3672 6.2621 144.8179 44210.5072]:[ 6.253 76.5541 166.2772 33322.3727] LL -- [z]:[p] = [ 1.3687 6.3996 143.1718 43502.3703]:[ 6.3907 76.0563 165.0157 32808.4948] UR -- [z]:[p] = [ 1.3825 5.3008 147.0927 45076.969 ]:[ 5.2921 77.333 168.416 33770.4005] LR -- [z]:[p] = [ 1.3649 6.1991 145.6464 43736.6081]:[ 6.1896 76.2953 166.4675 33192.9401] STATE 3 (ACQ OFF, LP ON) SUMMARY UL -- [z]:[p] = [ 12.213 27.8208 107.8732]:[ 2.4837 112.3264 1219.5588] LL -- [z]:[p] = [ 12.0483 27.4544 106.6765]:[ 2.4512 112.0677 1191.2231] UR -- [z]:[p] = [ 12.4118 27.9012 107.2568]:[ 2.4882 114.8804 1205.9678] LR -- [z]:[p] = [ 12.3018 27.9066 107.3295]:[ 2.4874 113.6251 1207.7893] STATE3 / STATE 1 SUMMARY UL -- [z]:[p] = [ 27.7758 109.4614]:[ 2.4789 1221.2812] LL -- [z]:[p] = [ 27.4216 106.8961]:[ 2.4469 1192.9877] UR -- [z]:[p] = [ 27.8521 108.0965 1015.3983]:[ 2.4843 1005.7548 1219.1481] LR -- [z]:[p] = [ 27.8487 108.3217]:[ 2.4833 1209.543 ]