Quick PMC optimization L05 start: 11.02mm L06 start: 5.0mm Adjust both lenses many mm in each direction, no real improvement Look to require more exhaustive work for opti, will move on to FSS work as higher priority Return lense to start positions MEDM appears to be having sporadic issues, intermittent freezing. FSS optimization Power budget: PBS01 IN: 296.0 mW SP AOM IN: 296.0 mW SP AOM OUT: 131.0 mW SP AOM Diff Efficiency: 44.3% DP AOM OUT: 83.3 mW DP AOM Diff Efficiency: 63.6% Adjust AOM to improve diffraction efficiency FSS optimization Power budget: SP AOM OUT: 201.8 mW SP AOM Diff Efficiency: 68.2% DP AOM OUT: 147.2 mW DP AOM Diff Efficiency: 72.9% RefCav locked w/ no issue, TPD ~= 0.33V Adjust pico mirrors to max TPD TPD = 0.94V Tweak alignment onto RefCav RFPD Unlocked: 1.250V Locked: 0.23V Visibility: 81.6% Leaving enclosure to turn off environmental controls for further tweaks Measure FSS TF from outside.