H1 SUS ITMY PUM Driver S1102654 /ligo/gitcommon/suspensions/ligo/electronics/fits/ fit_ITMY_PUM_driver_20220111.py no 2021-01-22 ~14:00 PST. The Answer: STATE 1 (ACQ OFF, LP OFF) SUMMARY UL -- [z]:[p] = [12.1727]:[113.5222] LL -- [z]:[p] = [12.2215]:[114.0451] UR -- [z]:[p] = [12.1864]:[113.6247] LR -- [z]:[p] = [12.1668]:[113.3231] STATE 2 (ACQ ON, LP OFF) SUMMARY UL -- [z]:[p] = [ 1.3624 141.9997]:[ 76.0372 163.3587] LL -- [z]:[p] = [ 1.3598 1.8606 145.0671 43720.253 ]:[ 1.8425 76.6348 166.5709 33938.5445] UR -- [z]:[p] = [ 1.3643 3.8835 144.8156 39995.3588]:[ 3.8786 76.1218 165.9018 31555.6203] LR -- [z]:[p] = [ 1.382 -0.j 143.8058-0.j 7428.3484-1.188j 7428.3484+1.188j]:[ 76.5642 165.8032 7388.6901 7388.6901] STATE 3 (ACQ OFF, LP ON) SUMMARY UL -- [z]:[p] = [ 12.1946 27.5081 107.3093]:[ 2.4528 111.6466 1219.6593] LL -- [z]:[p] = [ 12.2631 27.3905 107.1468]:[ 2.449 112.5818 1211.6564] UR -- [z]:[p] = [ 12.2128 27.5203 105.7721]:[ 2.4546 112.6817 1192.3252] LR -- [z]:[p] = [ 12.2266 27.8375 106.9881]:[ 2.4953 113.0188 1196.327 ] STATE3 / STATE 1 SUMMARY UL -- [z]:[p] = [ 26.3245 26.3246 109.4214]:[ 2.4481 25.2397 1221.3328] LL -- [z]:[p] = [ 27.4285 108.6187]:[ 2.4441 1213.0449] UR -- [z]:[p] = [ 27.5209 106.6734 717.1573]:[ 2.4495 713.9924 1198.7717] LR -- [z]:[p] = [ 26.4696 26.4698 107.4601]:[ 2.4908 25.1114 1198.0896] AOSEM IMPEDANCE SUMMARY ## NOTE, HAD TO INCREASE THE IIRRATIONAL SEED FIT ORDER FROM 3 TO 4. UL -- [z]:[p] = [ 115.0271 717.432 1320.7239 2871.971 ]:[ 119.3831 863.8511 2418.9031 19190.8737] LL -- [z]:[p] = [ 111.7524 672.5027 1180.3286 2313.592 ]:[ 115.9712 762.822 1922.0311 18963.9914] UR -- [z]:[p] = [ 110.7484 659.3383 1192.7736 2356.6321]:[ 114.7709 741.2987 1935.9688 18813.8693] LR -- [z]:[p] = [ 120.1063 906.2079 909.9114 1803.1924]:[ 125.1541-0.j 1086.7496-0.5036j 1086.7496+0.5036j 17644.5404-0.j ]