%%% OLD OLD OLD %%% filter switching set to Input "Zero History" and Output "Immediately" SimAcqOFF # DESIGN ITMY_L2_COILOUTF_UL 0 zpk([12],[109.984],1,"n") # DESIGN ITMY_L2_COILOUTF_LL 0 zpk([12],[109.984],1,"n") # DESIGN ITMY_L2_COILOUTF_UR 0 zpk([12],[109.984],1,"n") # DESIGN ITMY_L2_COILOUTF_LR 0 zpk([12],[109.984],1,"n") SimAcqON # DESIGN ITMY_L2_COILOUTF_UL 1 zpk([1.35],[80.4936],1,"n") # DESIGN ITMY_L2_COILOUTF_LL 1 zpk([1.35],[80.4936],1,"n") # DESIGN ITMY_L2_COILOUTF_UR 1 zpk([1.35],[80.4936],1,"n") # DESIGN ITMY_L2_COILOUTF_LR 1 zpk([1.35],[80.4936],1,"n") Sim LP # DESIGN ITMY_L2_COILOUTF_UL 2 zpk([6;19.9999],[0.5;249.809],1,"n") # DESIGN ITMY_L2_COILOUTF_LL 2 zpk([6;19.9999],[0.5;249.809],1,"n") # DESIGN ITMY_L2_COILOUTF_UR 2 zpk([6;19.9999],[0.5;249.809],1,"n") # DESIGN ITMY_L2_COILOUTF_LR 2 zpk([6;19.9999],[0.5;249.809],1,"n") AntiAcqOFF # DESIGN ITMY_L2_COILOUTF_UL 5 zpk([109.984],[12],1,"n") # DESIGN ITMY_L2_COILOUTF_LL 5 zpk([109.984],[12],1,"n") # DESIGN ITMY_L2_COILOUTF_UR 5 zpk([109.984],[12],1,"n") # DESIGN ITMY_L2_COILOUTF_LR 5 zpk([109.984],[12],1,"n") AntiAcqON # DESIGN ITMY_L2_COILOUTF_UL 6 zpk([80.4936],[1.35],1,"n") # DESIGN ITMY_L2_COILOUTF_LL 6 zpk([80.4936],[1.35],1,"n") # DESIGN ITMY_L2_COILOUTF_UR 6 zpk([80.4936],[1.35],1,"n") # DESIGN ITMY_L2_COILOUTF_LR 6 zpk([80.4936],[1.35],1,"n") AntiLP # DESIGN ITMY_L2_COILOUTF_UL 7 zpk([0.5;249.809],[6;19.9999],1,"n") # DESIGN ITMY_L2_COILOUTF_LL 7 zpk([0.5;249.809],[6;19.9999],1,"n") # DESIGN ITMY_L2_COILOUTF_UR 7 zpk([0.5;249.809],[6;19.9999],1,"n") # DESIGN ITMY_L2_COILOUTF_LR 7 zpk([0.5;249.809],[6;19.9999],1,"n") %%% NEW NEW NEW %%% filter switching set to Input "Always ON" and Output "Zero Crossing" SimAcqOFF # DESIGN ITMY_L2_COILOUTF_UL 0 zpk([12.1727],[113.5222],1,"n") # DESIGN ITMY_L2_COILOUTF_LL 0 zpk([12.2215],[114.0451],1,"n") # DESIGN ITMY_L2_COILOUTF_UR 0 zpk([12.1864],[113.6247],1,"n") # DESIGN ITMY_L2_COILOUTF_LR 0 zpk([12.1668],[113.3231],1,"n") SimAcqON # DESIGN ITMY_L2_COILOUTF_UL 1 zpk([1.3624;141.9997],[76.0372;163.3587],1,"n") # DESIGN ITMY_L2_COILOUTF_LL 1 zpk([1.3598;1.8606;145.0671],[1.8425;76.6348;166.5709],1,"n") # DESIGN ITMY_L2_COILOUTF_UR 1 zpk([1.3643;3.8835;144.8156],[3.8786;76.1218;165.9018],1,"n") # DESIGN ITMY_L2_COILOUTF_LR 1 zpk([1.3820;143.8058],[76.5642;165.8032],1,"n") Sim LP # DESIGN ITMY_L2_COILOUTF_UL 2 zpk([26.3245;26.3246;109.4214],[2.4481;25.2397;1221.3328],1,"n") # DESIGN ITMY_L2_COILOUTF_LL 2 zpk([27.4285;108.6187],[2.4441;1213.0449],1,"n") # DESIGN ITMY_L2_COILOUTF_UR 2 zpk([27.5209;106.6734;717.1573],[2.4495;713.9924;1198.7717],1,"n") # DESIGN ITMY_L2_COILOUTF_LR 2 zpk([26.4696;26.4698;107.4601],[2.4908;25.1114;1198.0896],1,"n") AntiAcqOFF # DESIGN ITMY_L2_COILOUTF_UL 5 zpk([113.5222],[12.1727],1,"n") # DESIGN ITMY_L2_COILOUTF_LL 5 zpk([114.0451],[12.2215],1,"n") # DESIGN ITMY_L2_COILOUTF_UR 5 zpk([113.6247],[12.1864],1,"n") # DESIGN ITMY_L2_COILOUTF_LR 5 zpk([113.3231],[12.1668],1,"n") AntiAcqON # DESIGN ITMY_L2_COILOUTF_UL 6 zpk([76.0372;163.3587],[1.3624;141.9997],1,"n") # DESIGN ITMY_L2_COILOUTF_LL 6 zpk([1.8425;76.6348;166.5709],[1.3598;1.8606;145.0671],1,"n") # DESIGN ITMY_L2_COILOUTF_UR 6 zpk([3.8786;76.1218;165.9018],[1.3643;3.8835;144.8156],1,"n") # DESIGN ITMY_L2_COILOUTF_LR 6 zpk([76.5642;165.8032],[1.3820;143.8058],1,"n") AntiLP # DESIGN ITMY_L2_COILOUTF_UL 7 zpk([2.4481;25.2397;1221.3328],[26.3245;26.3246;109.4214],1,"n") # DESIGN ITMY_L2_COILOUTF_LL 7 zpk([2.4441;1213.0449],[27.4285;108.6187],1,"n") # DESIGN ITMY_L2_COILOUTF_UR 7 zpk([2.4495;713.9924;1198.7717],[27.5209;106.6734;717.1573],1,"n") # DESIGN ITMY_L2_COILOUTF_LR 7 zpk([2.4908;25.1114;1198.0896],[26.4696;26.4698;107.4601],1,"n") AntiAOSEM # DESIGN ITMY_L2_COILOUTF_UL 8 zpk([119.3831;863.8511;2418.9031],[115.0271;717.4320;1320.7239;2871.9710],1,"n") # DESIGN ITMY_L2_COILOUTF_LL 8 zpk([115.9712;762.8220;1922.0311],[111.7524;672.5027;1180.3286;2313.5920],1,"n") # DESIGN ITMY_L2_COILOUTF_UR 8 zpk([114.7709;741.2987;1935.9688],[110.7484;659.3383;1192.7736;2356.6321],1,"n") # DESIGN ITMY_L2_COILOUTF_LR 8 zpk([125.1541;1086.7496+i*0.5036;1086.7496-i*0.5036],[120.1063;906.2079;909.9114;1803.1924],1,"n")