OMC Scan 10 W input, single bounce 100 s scan starting at GPS 1333496192 Time (s) fit to frequency (MHz) with sixth-order polynomial fit --------------------- 00 Order ---- Label Freq [MHz] OMC sum [mA] Power Ratio to CA00 CA_{00} -0.015568 14.6815 0.98735 CA_{00} 264.8188 14.8697 1 9_{00}+ 9.1241 0.16801 0.011299 9_{00}- 255.7548 0.16974 0.011415 45_{00}+ 45.4872 0.27922 0.018778 45_{00}- 219.3458 0.28077 0.018882 118_{00}+ 117.9362 0.0015901 0.00010694 10 Order ---- Label Freq [MHz] OMC sum [mA] Power Ratio to CA10 CA_{10} 206.9218 0.26731 1 9_{10}- 197.7774 0.0042223 0.015796 9_{10}+ 216.0906 0.0074827 0.027993 45_{10}- 161.1443 0.0062464 0.023368 45_{10}+ 252.6086 0.016774 0.062752 20 Order ---- Label Freq [MHz] OMC sum [mA] Power Ratio to CA20 CA_{20} 149.1796 0.53702 1 9_{20}- 140.057 0.0069057 0.012859 9_{20}+ 158.2874 0.0071974 0.013403 45_{20}- 103.7107 0.010993 0.02047 45_{20}+ 194.9141 0.011189 0.020836 30-90 Order ---- Label Freq [MHz] OMC sum [mA] 9_{90}+ 18.295 0.0056471 9_{40}- 24.41 0.0034448 CA_{40} 33.51 0.017797 9_{40}+ 42.61 0.0049465 9_{80}- 57.92 0.00092137 CA_{80} 67.02 0.001088 9_{80}+ 76.12 0.00051011 9_{30}- 82.235 0.00064479 CA_{30} 91.335 0.01374 9_{30}+ 100.435 0.0010501 9_{70}- 115.745 0.00069253 CA_{70} 124.845 0.0017904 9_{70}+ 133.945 0.00082116 45_{30}+ 136.835 0.0014866 9_{60}- 173.57 0.002062 CA_{60} 182.67 0.0018643 9_{60}+ 191.77 0.0011425 9_{50}- 231.395 0.0020644 CA_{50} 240.495 0.0036392 9_{50}+ 249.595 0.0075339 -------------------- 9_{90}- (0.095 MHz) is indistinguishable from a lower order mode CA_{90} (9.195 MHz) is indistinguishable from a lower order mode 45_{30}- (45.835 MHz) is indistinguishable from a lower order mode 45_{40}- (252.82 MHz) is indistinguishable from a lower order mode 45_{50}- (194.995 MHz) is indistinguishable from a lower order mode -------------------- The RF9 upper sideband modulation depth is 0.21025. The RF9 lower sideband modulation depth is 0.2113. The RF45 upper sideband modulation depth is 0.2691. The RF45 lower sideband modulation depth is 0.26982.