OMC Scan 50 W input, single bounce, ITMX 100 s scan starting at GPS 1335042817 Time (s) fit to frequency (MHz) with ninth-order polynomial fit --------------------- 00 Order Label Freq [MHz] OMC sum [mA] Power Ratio to CA_00 CA_{00} 0.10377 67.56 0.91791 CA_{00} 264.9079 67.32 0.91465 9_{00}+ 9.1128 0.81 0.011005 9_{00}- 255.7089 0.82 0.011141 45_{00}+ 45.4159 1.36 0.018478 45_{00}- 219.2532 1.37 0.018614 118_{00}+ 117.9948 0.01 0.00013587 --------------------- First Order Label Freq [MHz] OMC sum [mA] Power Ratio to CA_10 CA_{10} 206.994 1.53 1 9_{10}- 197.8867 0.02 0.013072 9_{10}+ 216.2283 0.03 0.019608 45_{10}- 161.332 0.03 0.019608 45_{10}+ 252.702 0.1 0.065359 --------------------- Second Order Label Freq [MHz] OMC sum [mA] Power Ratio to CA_20 CA_{20} 149.2012 3.22 1 9_{20}- 140.1139 0.04 0.012422 9_{20}+ 158.3238 0.05 0.015528 45_{20}- 103.7204 0.07 0.021739 45_{20}+ 194.8723 0.07 0.021739 --------------------- Sideband Modulations Label Freq [MHz] OMC sum [mA] SB mod 36.3053 0.029689 SB mod 54.5062 0.019508 SB mod 210.0747 0.035 --------------------- Carriers Order 3-9 Label Freq [MHz] OMC sum [mA] CA_{30} 91.577 0.12062 CA_{40} 33.915 0.21563 CA_{60} 183.5921 0.067716 CA_{70} 125.7584 0.016655 Lower Sideband 9 Order 3-9 Label Freq [MHz] OMC sum [mA] 9_{30}- 82.4908 0.0052615 9_{40}- 24.8538 0.01791 9_{60}- 173.6316 0.0097664 --------------------- Upper Sideband 9 Order 3-9 Label Freq [MHz] OMC sum [mA] 9_{30}+ 100.6785 0.01039 --------------------- Lower Sideband 45 Order 3-5 Label Freq [MHz] OMC sum [mA] --------------------- Upper Sideband 45 Order 3-6 Label Freq [MHz] OMC sum [mA] 45_{30}+ 137.0903 0.012419 45_{40}+ 79.3573 0.0065417 45_{60}+ 228.3969 0.023487 -------------------- The RF9 upper sideband modulation depth is 0.21699. The RF9 lower sideband modulation depth is 0.2187. The RF45 upper sideband modulation depth is 0.27898. The RF45 lower sideband modulation depth is 0.27943. Note: if single bounce scan is taken with input beam greater than 50W, there is carrier saturation. Modulation depths are incorrect in this case.