OMC Scan 50 W input, single bounce, ITMY 100 s scan starting at GPS 1335044281 Time (s) fit to frequency (MHz) with ninth-order polynomial fit --------------------- 00 Order Label Freq [MHz] OMC sum [mA] Power Ratio to CA_00 CA_{00} 0.11152 67.38 0.89611 CA_{00} 264.8946 67.3 0.89504 9_{00}+ 9.098 0.82 0.010905 9_{00}- 255.693 0.83 0.011038 45_{00}+ 45.4266 1.36 0.018087 45_{00}- 219.2944 1.35 0.017954 118_{00}+ 117.9819 0.01 0.00013299 --------------------- First Order Label Freq [MHz] OMC sum [mA] Power Ratio to CA_10 CA_{10} 206.9688 1.03 1 9_{10}- 197.7269 0.01 0.0097087 9_{10}+ 216.3017 0.04 0.038835 45_{10}- 161.3489 0.03 0.029126 45_{10}+ 252.681 0.09 0.087379 --------------------- Second Order Label Freq [MHz] OMC sum [mA] Power Ratio to CA_20 CA_{20} 149.1947 3.27 1 9_{20}- 140.125 0.05 0.015291 9_{20}+ 158.3054 0.05 0.015291 45_{20}- 103.7164 0.07 0.021407 45_{20}+ 194.8627 0.08 0.024465 --------------------- Sideband Modulations Label Freq [MHz] OMC sum [mA] SB mod 36.3252 0.028812 SB mod 54.4907 0.019369 SB mod 210.0961 0.03212 --------------------- Carriers Order 3-9 Label Freq [MHz] OMC sum [mA] CA_{30} 91.5786 0.22889 CA_{40} 33.9634 0.29551 CA_{60} 183.6604 0.090797 CA_{70} 125.7554 0.038965 Lower Sideband 9 Order 3-9 Label Freq [MHz] OMC sum [mA] 9_{30}- 82.516 0.012408 9_{60}- 173.6572 0.0095639 --------------------- Upper Sideband 9 Order 3-9 Label Freq [MHz] OMC sum [mA] 9_{30}+ 100.6921 0.0077796 --------------------- Lower Sideband 45 Order 3-5 Label Freq [MHz] OMC sum [mA] --------------------- Upper Sideband 45 Order 3-6 Label Freq [MHz] OMC sum [mA] 45_{30}+ 137.084 0.010803 45_{40}+ 79.3577 0.0061403 45_{60}+ 228.4407 0.023275 -------------------- The RF9 upper sideband modulation depth is 0.21792. The RF9 lower sideband modulation depth is 0.2189. The RF45 upper sideband modulation depth is 0.27844. The RF45 lower sideband modulation depth is 0.27774. Note: if single bounce scan is taken with input beam greater than 50W, there is carrier saturation. Modulation depths are incorrect in this case.