OMC Scan 60 W input, single bounce, ITMY 100 s scan starting at GPS 1335044788 Time (s) fit to frequency (MHz) with ninth-order polynomial fit --------------------- 00 Order Label Freq [MHz] OMC sum [mA] Power Ratio to CA_00 CA_{00} 0.11418 70.28 0.90315 CA_{00} 264.888 70.44 0.90521 9_{00}+ 9.0966 0.97 0.012465 9_{00}- 255.6949 0.98 0.012594 45_{00}+ 45.4368 1.6 0.020561 45_{00}- 219.2012 1.63 0.020947 118_{00}+ 118.0344 0.01 0.00012851 --------------------- First Order Label Freq [MHz] OMC sum [mA] Power Ratio to CA_10 CA_{10} 207.074 4.7 1 9_{10}- 197.9282 0.03 0.006383 9_{10}+ 216.2325 0.04 0.0085106 45_{10}- 161.4323 0.07 0.014894 45_{10}+ 252.66 0.1 0.021277 --------------------- Second Order Label Freq [MHz] OMC sum [mA] Power Ratio to CA_20 CA_{20} 149.17 4.49 1 9_{20}- 140.0678 0.06 0.013363 9_{20}+ 158.3034 0.05 0.011136 45_{20}- 103.7051 0.09 0.020045 45_{20}+ 194.8381 0.08 0.017817 --------------------- Sideband Modulations Label Freq [MHz] OMC sum [mA] SB mod 36.3579 0.034092 SB mod 54.5044 0.022319 --------------------- Carriers Order 3-9 Label Freq [MHz] OMC sum [mA] CA_{30} 91.6055 0.21832 CA_{40} 33.9637 0.21102 CA_{60} 183.5373 0.15765 CA_{70} 125.7871 0.049681 Lower Sideband 9 Order 3-9 Label Freq [MHz] OMC sum [mA] 9_{30}- 82.5665 0.01313 9_{40}- 24.8667 0.022232 9_{60}- 173.5573 0.011475 --------------------- Upper Sideband 9 Order 3-9 Label Freq [MHz] OMC sum [mA] --------------------- Lower Sideband 45 Order 3-5 Label Freq [MHz] OMC sum [mA] --------------------- Upper Sideband 45 Order 3-6 Label Freq [MHz] OMC sum [mA] 45_{30}+ 137.0347 0.014025 45_{40}+ 79.4239 0.010412 45_{60}+ 228.3547 0.028026 -------------------- The RF9 upper sideband modulation depth is 0.23199. The RF9 lower sideband modulation depth is 0.23244. The RF45 upper sideband modulation depth is 0.29494. The RF45 lower sideband modulation depth is 0.29721. Note: if single bounce scan is taken with input beam greater than 50W, there is carrier saturation. Modulation depths are incorrect in this case.