francisco.llamas@cdsws22: python KappaToDrivealign.py -d -p -n Fetching from 1401031920 to 1401044520 Opening new connection to h1daqnds1... connected [h1daqnds1] set ALLOW_DATA_ON_TAPE='False' Checking channels list against NDS2 database... done Downloading data: |████████████████████████████████████████████████████████████████████| 12601.0/12601.0 (100%) ETA 00:00 Warning: IFO has been locked less than 3.5 hours. qt.qpa.xcb: QXcbConnection: XCB error: 3 (BadWindow), sequence: 2978, resource id: 22433536, major code: 40 (TranslateCoords), minor code: 0 Average H1:CAL-CS_TDEP_KAPPA_TST_OUTPUT is -2.2632% from 1. Accept changes of H1:SUS-ETMX_L3_DRIVEALIGN_L2L_GAIN from 184.649994 to 188.828973 and H1:CAL-CS_DARM_FE_ETMX_L3_DRIVEALIGN_L2L_GAIN from 184.649994 to 188.828973 Proceed? [yes/no] no No changes made to H1:SUS-ETMX_L3_DRIVEALIGN_L2L_GAIN and H1:CAL-CS_DARM_FE_ETMX_L3_DRIVEALIGN_L2L_GAIN Exiting now. ------------------------------------------------------------------------------------------------------------------------------------------ francisco.llamas@cdsws22: python KappaToDrivealign.py -d -p -n Fetching from 1401047305 to 1401059905 Opening new connection to h1daqnds1... connected [h1daqnds1] set ALLOW_DATA_ON_TAPE='False' Checking channels list against NDS2 database... done Downloading data: |████████████████████████████████████████████████████████████████████| 12601.0/12601.0 (100%) ETA 00:00 qt.qpa.xcb: QXcbConnection: XCB error: 3 (BadWindow), sequence: 2308, resource id: 22497966, major code: 40 (TranslateCoords), minor code: 0 qt.qpa.xcb: QXcbConnection: XCB error: 3 (BadWindow), sequence: 2967, resource id: 21604604, major code: 40 (TranslateCoords), minor code: 0 Average H1:CAL-CS_TDEP_KAPPA_TST_OUTPUT is -1.3376% from 1. Accept changes of H1:SUS-ETMX_L3_DRIVEALIGN_L2L_GAIN from 184.649994 to 187.119952 and H1:CAL-CS_DARM_FE_ETMX_L3_DRIVEALIGN_L2L_GAIN from 184.649994 to 187.119952 Proceed? [yes/no] no No changes made to H1:SUS-ETMX_L3_DRIVEALIGN_L2L_GAIN and H1:CAL-CS_DARM_FE_ETMX_L3_DRIVEALIGN_L2L_GAIN Exiting now. ------------------------------------------------------------------------------------------------------------------------------------------ francisco.llamas@cdsws22: python KappaToDrivealign.py -d -p Fetching from 1402261900 to 1402274500 Opening new connection to h1daqnds1... connected [h1daqnds1] set ALLOW_DATA_ON_TAPE='False' Checking channels list against NDS2 database... done Downloading data: |████████████████████████████████████████████████████████████████████| 12601.0/12601.0 (100%) ETA 00:00 Warning: IFO has been locked less than 3.5 hours. qt.qpa.xcb: QXcbConnection: XCB error: 3 (BadWindow), sequence: 1643, resource id: 22632808, major code: 40 (TranslateCoords), minor code: 0 Average H1:CAL-CS_TDEP_KAPPA_TST_OUTPUT is -1.6457% from 1. Accept changes of H1:SUS-ETMX_L3_DRIVEALIGN_L2L_GAIN from 184.649994 to 187.688763 and H1:CAL-CS_DARM_FE_ETMX_L3_DRIVEALIGN_L2L_GAIN from 184.649994 to 187.688763 Proceed? [yes/no] yes Changing H1:SUS-ETMX_L3_DRIVEALIGN_L2L_GAIN and H1:CAL-CS_DARM_FE_ETMX_L3_DRIVEALIGN_L2L_GAIN NOT WRITING: SUS-ETMX_L3_DRIVEALIGN_L2L_GAIN = 187.68876304596296 NOT WRITING: SUS-ETMX_L3_DRIVEALIGN_L2L_GAIN = 187.68876304596296