Cluster id415 1. 348.11422542 Tooth of 1.10864403 Hz comb n=314 2. 74.7505935 Tooth of 1.6611243 Hz comb n=45 3. 11.475 Calibration line (thermalization line DARM_EXC) 4. 15.175 Calibration line (thermalization line DARM_EXC) 5. 24.4 Calibration line (thermalization line DARM_EXC) 6. 11.975 Temporary calibration line intermod -17.100+17.600+11.475 Hz; segments determined from aLOGs/Fscans; 1 day-resolution 7. 17.65 Temporary calibration line intermod 2*8.825 Hz; segments determined from aLOGs/Fscans; 1 day-resolution 8. 20.3 Temporary calibration line intermod 8.825+11.475 Hz; segments determined from aLOGs/Fscans; 1 day-resolution 9. 24.0 Temporary calibration line intermod 8.825+15.175 Hz; segments determined from aLOGs/Fscans; 1 day-resolution 10. 24.9 Temporary calibration line intermod -17.100+17.600+24.400 Hz; segments determined from aLOGs/Fscans; 1 day-resolution 11. 26.475 Temporary calibration line intermod 3*8.825 Hz; segments determined from aLOGs/Fscans; 1 day-resolution 12. 29.125 Temporary calibration line intermod -16.400+3*15.175 Hz; segments determined from aLOGs/Fscans; 1 day-resolution 13. 31.775 Temporary calibration line intermod 8.825+2*11.475 Hz; segments determined from aLOGs/Fscans; 1 day-resolution 14. 32.775 Temporary calibration line intermod 17.600+15.175 Hz; segments determined from aLOGs/Fscans; 1 day-resolution 15. 33.225 Temporary calibration line intermod 8.825+24.400 Hz; segments determined from aLOGs/Fscans; 1 day-resolution 16. 33.325 Temporary calibration line intermod 8.925+24.400 Hz; segments determined from aLOGs/Fscans; 1 day-resolution 17. 35.475 Temporary calibration line intermod 8.825+11.475+15.175 Hz; segments determined from aLOGs/Fscans; 1 day-resolution 18. 35.875 Temporary calibration line intermod 11.475+24.400 Hz; segments determined from aLOGs/Fscans; 1 day-resolution 19. 35.975 Temporary calibration line intermod 11.575+24.400 Hz; segments determined from aLOGs/Fscans; 1 day-resolution 20. 39.575 Temporary calibration line intermod 15.175+24.400 Hz; segments determined from aLOGs/Fscans; 1 day-resolution 21. 39.975 Temporary calibration line intermod -8.925+24.500+24.400 Hz; segments determined from aLOGs/Fscans; 1 day-resolution 22. 40.8 Temporary calibration line intermod 16.400+24.400 Hz; segments determined from aLOGs/Fscans; 1 day-resolution 23. 41.5 Temporary calibration line intermod 17.100+24.400 Hz; segments determined from aLOGs/Fscans; 1 day-resolution 24. 42.0 Temporary calibration line intermod 17.600+24.400 Hz; segments determined from aLOGs/Fscans; 1 day-resolution 25. 42.05 Temporary calibration line intermod -77.730+102.130+2*8.825 Hz; segments determined from aLOGs/Fscans; 1 day-resolution 26. 44.7 Temporary calibration line intermod 8.825+11.475+24.400 Hz; segments determined from aLOGs/Fscans; 1 day-resolution 27. 48.4 Temporary calibration line intermod 2*8.925+2*15.275 Hz; segments determined from aLOGs/Fscans; 1 day-resolution 28. 48.8 Temporary calibration line intermod 2*24.400 Hz; segments determined from aLOGs/Fscans; 1 day-resolution 29. 48.9 Temporary calibration line intermod 24.500+24.400 Hz; segments determined from aLOGs/Fscans; 1 day-resolution 30. 50.325 Temporary calibration line intermod 17.100+8.825+24.400 Hz; segments determined from aLOGs/Fscans; 1 day-resolution 31. 51.05 Temporary calibration line intermod 15.600+17.600+2*8.925 Hz; segments determined from aLOGs/Fscans; 1 day-resolution 32. 54.75 Temporary calibration line intermod 8.925+3*15.275 Hz; segments determined from aLOGs/Fscans; 1 day-resolution 33. 57.625 Temporary calibration line intermod 8.825+2*24.400 Hz; segments determined from aLOGs/Fscans; 1 day-resolution 34. 60.275 Temporary calibration line intermod 11.475+2*24.400 Hz; segments determined from aLOGs/Fscans; 1 day-resolution 35. 63.975 Temporary calibration line intermod 15.175+2*24.400 Hz; segments determined from aLOGs/Fscans; 1 day-resolution 36. 68.7 Temporary calibration line intermod 16.400+17.100+2*17.600 Hz; segments determined from aLOGs/Fscans; 1 day-resolution 37. 32.825 Unidentified line !1 working 38. 401.475 Unidentified peak !1 working 39. 419.125 Unidentified peak !1 working 40. 477.50167 Unidentified peak; possible violin mode contamination !1 working 41. 486.32667 Unidentified peak; possible violin mode contamination !1 working 42. 486.72667 Unidentified peak; possible violin mode contamination !1 working 43. 490.42667 Unidentified peak; possible violin mode contamination !1 working 44. 495.15167 Unidentified peak; possible violin mode contamination !1 working 45. 495.55167 Unidentified peak; possible violin mode contamination !1 working 46. 497.80181 Unidentified peak; possible violin mode contamination !1 working 47. 499.15181 Unidentified peak; possible violin mode contamination !1 working 48. 499.25167 Unidentified peak; possible violin mode contamination !1 working 49. 501.90167 Unidentified peak; possible violin mode contamination !1 working 50. 517.07667 Unidentified peak; possible violin mode contamination !1 working 51. 519.55167 Unidentified peak; possible violin mode contamination !1 working 52. 519.65181 Unidentified peak; possible violin mode contamination !1 working 53. 522.20167 Unidentified peak; possible violin mode contamination !1 working 54. 525.90167 Unidentified peak; possible violin mode contamination !1 working 55. 526.30167 Unidentified peak; possible violin mode contamination !1 working 56. 531.02667 Unidentified peak; possible violin mode contamination !1 working 57. 534.72667 Unidentified peak; possible violin mode contamination !1 working 58. 535.12667 Unidentified peak; possible violin mode contamination !1 working 59. 543.95167 Unidentified peak !1 working 60. 959.89347 Unidentified peak; possible violin mode contamination !1 working 61. 964.6475 Unidentified peak; possible violin mode contamination !1 working 62. 969.11847 Unidentified peak; possible violin mode contamination !1 working 63. 972.81847 Unidentified peak; possible violin mode contamination !1 working 64. 973.4725 Unidentified peak; possible violin mode contamination !1 working 65. 975.46847 Unidentified peak; possible violin mode contamination !1 working 66. 975.89431 Unidentified peak; possible violin mode contamination !1 working 67. 977.5725 Unidentified peak; possible violin mode contamination !1 working 68. 979.91778 Unidentified peak; possible violin mode contamination !1 working 69. 980.2225 Unidentified peak; possible violin mode contamination !1 working 70. 982.04347 Unidentified peak; possible violin mode contamination !1 working 71. 984.29347 Unidentified peak; possible violin mode contamination !1 working 72. 984.41639 Unidentified peak; possible violin mode contamination !1 working 73. 984.69347 Unidentified peak; possible violin mode contamination !1 working 74. 985.11931 Unidentified peak; possible violin mode contamination !1 working 75. 991.04347 Unidentified peak; possible violin mode contamination !1 working 76. 991.46931 Unidentified peak; possible violin mode contamination !1 working 77. 993.11847 Unidentified peak; possible violin mode contamination !1 working 78. 993.51847 Unidentified peak; possible violin mode contamination !1 working 79. 995.76847 Unidentified peak; possible violin mode contamination !1 working 80. 997.21847 Unidentified peak; possible violin mode contamination !1 working 81. 997.56778 Unidentified peak; possible violin mode contamination !1 working 82. 997.8725 Unidentified peak; possible violin mode contamination !1 working 83. 1002.34347 Unidentified peak; possible violin mode contamination !1 working 84. 1015.04347 Unidentified peak; possible violin mode contamination !1 working 85. 1015.46931 Unidentified peak; possible violin mode contamination !1 working 86. 1017.51847 Unidentified peak; possible violin mode contamination !1 working 87. 1017.64139 Unidentified peak; possible violin mode contamination !1 working 88. 1020.16847 Unidentified peak; possible violin mode contamination !1 working 89. 1021.61847 Unidentified peak; possible violin mode contamination !1 working 90. 1022.2725 Unidentified peak; possible violin mode contamination !1 working 91. 1023.86847 Unidentified peak; possible violin mode contamination !1 working 92. 1024.26847 Unidentified peak; possible violin mode contamination !1 working 93. 1024.69431 Unidentified peak; possible violin mode contamination !1 working 94. 1026.34347 Unidentified peak; possible violin mode contamination !1 working 95. 1028.99347 Unidentified peak; possible violin mode contamination !1 working 96. 1032.69347 Unidentified peak; possible violin mode contamination !1 working 97. 1033.09347 Unidentified peak; possible violin mode contamination !1 working 98. 1035.34347 Unidentified peak; possible violin mode contamination !1 working 99. 1041.91847 Unidentified peak; possible violin mode contamination !1 working 100. 1044.56847 Unidentified peak; possible violin mode contamination !1 working 101. 1048.26847 Unidentified peak; possible violin mode contamination !1 working 102. 1440.62194444 Unidentified peak; possible violin mode contamination !1 working 103. 1444.18722222 Unidentified peak; possible violin mode contamination !1 working 104. 1446.89486111 Unidentified peak; possible violin mode contamination !1 working 105. 1449.44694444 Unidentified peak; possible violin mode contamination !1 working 106. 1449.84694444 Unidentified peak; possible violin mode contamination !1 working 107. 1452.09694 Unidentified peak; possible violin mode contamination !1 working 108. 1453.54694444 Unidentified peak; possible violin mode contamination !1 working 109. 1455.70277778 Unidentified peak; possible violin mode contamination !1 working 110. 1456.19694444 Unidentified peak; possible violin mode contamination !1 working 111. 1457.11222222 Unidentified peak; possible violin mode contamination !1 working 112. 1457.57041667 Unidentified peak; possible violin mode contamination !1 working 113. 1458.56430556 Unidentified peak; possible violin mode contamination !1 working 114. 1458.74361 Unidentified peak; possible violin mode contamination !1 working 115. 1459.76222222 Unidentified peak; possible violin mode contamination !1 working 116. 1461.393611 Tracked Line 117. 1462.46986111 Unidentified peak; possible violin mode contamination !1 working 118. 1475.19083333 Unidentified peak; possible violin mode contamination !1 working 119. 1476.21430556 Unidentified peak; possible violin mode contamination !1 working 120. 1476.49694444 Unidentified peak; possible violin mode contamination !1 working 121. 1477.41222222 Unidentified peak; possible violin mode contamination !1 working 122. 1480.11986111 Unidentified peak; possible violin mode contamination !1 working 123. 1480.19694444 Unidentified peak; possible violin mode contamination !1 working 124. 1489.42194444 Unidentified peak; possible violin mode contamination !1 working 125. 1490.76583333 Unidentified peak; possible violin mode contamination !1 working 126. 1508.41583 Unidentified peak; possible violin mode contamination !1 working 127. 1511.06583 Unidentified peak; possible violin mode contamination !1 working 128. 1523.99083 Unidentified peak; possible violin mode contamination !1 working 129. 1532.81583 Unidentified peak; possible violin mode contamination !1 working Cluster id433 1. 1923.0 Tooth of 1.0 Hz comb n=1923 2. 231.70660227 Tooth of 1.10864403 Hz comb n=209 3. 300.44253213 Tooth of 1.10864403 Hz comb n=271 4. 38.2058589 Tooth of 1.6611243 Hz comb n=23 5. 637.9842304 Tooth of 4.9842518 Hz comb n=128 6. 1032.6968579 Tooth of 9.4742831 Hz comb n=109 7. 1023.9037092 Tooth of 9.4805899 Hz comb n=108 8. 48.825 Temporary calibration line intermod 15.600+8.825+24.400 Hz; segments determined from aLOGs/Fscans; 1 day-resolution 9. 49.625 Temporary calibration line intermod 16.400+8.825+24.400 Hz; segments determined from aLOGs/Fscans; 1 day-resolution 10. 50.825 Temporary calibration line intermod 16.400+3*11.475 Hz; segments determined from aLOGs/Fscans; 1 day-resolution 11. 40.0 Unidentified peak !1 working 12. 951.46847 Unidentified peak; possible violin mode contamination !1 working 13. 955.8225 Unidentified peak; possible violin mode contamination !1 working 14. 964.39347 Unidentified peak; possible violin mode contamination !1 working 15. 966.46847 Unidentified peak; possible violin mode contamination !1 working 16. 967.89347 Unidentified peak; possible violin mode contamination !1 working 17. 971.76847 Unidentified peak; possible violin mode contamination !1 working 18. 979.16847 Unidentified peak; possible violin mode contamination !1 working 19. 982.26847 Unidentified peak; possible violin mode contamination !1 working 20. 983.46847 Unidentified peak; possible violin mode contamination !1 working 21. 984.19347 Unidentified peak; possible violin mode contamination !1 working 22. 984.26847 Unidentified peak; possible violin mode contamination !1 working 23. 996.81847 Unidentified peak; possible violin mode contamination !1 working 24. 997.11847 Unidentified peak; possible violin mode contamination !1 working 25. 997.34139 Unidentified peak; possible violin mode contamination !1 working 26. 1013.4475 Unidentified peak; possible violin mode contamination !1 working 27. 1015.26847 Unidentified peak; possible violin mode contamination !1 working 28. 1016.26847 Unidentified peak; possible violin mode contamination !1 working 29. 1017.46847 Unidentified peak; possible violin mode contamination !1 working 30. 1017.61847 Unidentified peak; possible violin mode contamination !1 working 31. 1017.91847 Unidentified peak; possible violin mode contamination !1 working 32. 1020.26847 Unidentified peak; possible violin mode contamination !1 working 33. 1020.29139 Unidentified peak; possible violin mode contamination !1 working 34. 1024.16847 Unidentified peak; possible violin mode contamination !1 working 35. 1026.44347 Unidentified peak; possible violin mode contamination !1 working 36. 1026.74347 Unidentified peak; possible violin mode contamination !1 working 37. 1033.11847 Unidentified peak; possible violin mode contamination !1 working 38. 1033.19347 Unidentified peak; possible violin mode contamination !1 working 39. 1033.21639 Unidentified peak; possible violin mode contamination !1 working 40. 1035.11847 Unidentified peak; possible violin mode contamination !1 working 41. 1045.61847 Unidentified peak; possible violin mode contamination !1 working 42. 1047.04347 Unidentified peak; possible violin mode contamination !1 working 43. 1052.99347 Unidentified peak; possible violin mode contamination !1 working 44. 1057.49347 Unidentified peak; possible violin mode contamination !1 working 45. 1059.74347 Unidentified peak; possible violin mode contamination !1 working 46. 1440.12763889 Unidentified peak; possible violin mode contamination !1 working 47. 1442.98930556 Unidentified peak; possible violin mode contamination !1 working 48. 1444.72194444 Unidentified peak; possible violin mode contamination !1 working 49. 1448.37847222 Unidentified peak; possible violin mode contamination !1 working 50. 1449.35263889 Unidentified peak; possible violin mode contamination !1 working 51. 1452.21430556 Unidentified peak; possible violin mode contamination !1 working 52. 1453.05277778 Unidentified peak; possible violin mode contamination !1 working 53. 1455.71986111 Unidentified peak; possible violin mode contamination !1 working 54. 1456.11986111 Unidentified peak; possible violin mode contamination !1 working 55. 1457.60347 Unidentified peak; possible violin mode contamination !1 working 56. 1459.81986111 Unidentified peak; possible violin mode contamination !1 working 57. 1476.00277778 Unidentified peak; possible violin mode contamination !1 working 58. 1478.86430556 Unidentified peak; possible violin mode contamination !1 working 59. 1486.46986111 Unidentified peak; possible violin mode contamination !1 working 60. 1488.92777778 Unidentified peak; possible violin mode contamination !1 working 61. 1503.17486 Unidentified peak; possible violin mode contamination !1 working 62. 1503.48833 Unidentified peak; possible violin mode contamination !1 working 63. 1505.82486 Unidentified peak; possible violin mode contamination !1 working 64. 1507.18833 Unidentified peak; possible violin mode contamination !1 working 65. 1509.20542 Unidentified peak; possible violin mode contamination !1 working 66. 1516.41333 Unidentified peak; possible violin mode contamination !1 working 67. 1527.4825 Unidentified peak; possible violin mode contamination !1 working