(diskless)controls@h1sush7:~$ /opt/DIS/sbin/dis_diag -V 9 ================================================================================ Dolphin diagnostic tool -- dis_diag version 5.20.1 (Tue Feb 14 21:18:20 UTC 2023) ================================================================================ dis_diag compiled in 64 bit mode Driver : Dolphin IRM (GX) 5.20.1 Sept 12th 2022 (rev DIS_RELEASE_5_20_1_SEPT_12_2022) Date : Wed 09 Oct 2024 04:02:12 PM PDT System : Linux h1sush7 4.19.0-23-amd64 #1 SMP Debian 4.19.269-1 (2022-12-20) x86_64 GNU/Linux Number of configured local adapters found: 1 Adapter 0 > Type : IXH611 Mode : NTB NodeId : 92 Serial number : IXH611-CE-002475 IXH chip family : IDT_LOGAN IXH chip vendorId : 0x111d IXH chip device : 0x8091 IXH chip revision : ZC EEPROM version : 08 EEPROM vendor info : 0x0000 EEPROM swmode[3:0] : 0010 EEPROM images : 03 Card revision : CE Topology type : Switch Topology Autodetect : No Number of enabled links : 1 Max payload size (MPS) : 256 Multicast group size : 16 MB Multicast groups : 4 BAR2 (Prefetch space) : 256 MB BAR4 : 64 MB BAR5 : 8 MB Clock mode slot : Port Clock mode link : Port PCIe slot hwport : P00 PCIe slot state : x8, Gen2 (5 GT/s) PCIe slot capabilities : x8, Gen2 (5 GT/s) ************************* IXH ADAPTER 0 LINK 0 STATE ************************* Link 0 state : ENABLED Link 0 state : x8, Gen2 (5 GT/s) Link 0 required : x8, Gen2 (5 GT/s) Link 0 capabilities : x8, Gen2 (5 GT/s) Link 0 hwport : P08 Link 0 cable inserted : 1 Link 0 active : 1 Link 0 configuration : NTB **************************** IXH ADAPTER 0 STATUS **************************** Chip temperature : 65 C / 149 F Adapter state : 1 EEPROM init done : 1 *************** IXH ADAPTER 0, PARTNER INFORMATION FOR LINK 0 *************** Partner switch type : IXS600, 8 chassis ports (x8) Partner connector type : iPass Partner board type : IXS600 Partner switch topology : SINGLE Partner switch no : SUB2, chassis port 1 Partner link state : x8, Gen2 (5 GT/s) Partner link capabilities : NA Partner logical links : 8 (x8) ***************************** TEST OF ADAPTER 0 ***************************** OK: IXH chip alive in adapter 0. OK: Link alive in adapter 0. ==> Local adapter 0 ok. [WARN] Node 68 not reachable, but is an entry in the dishosts.conf file [WARN] Node 72 not reachable, but is an entry in the dishosts.conf file [WARN] Node 76 not reachable, but is an entry in the dishosts.conf file [WARN] Node 80 not reachable, but is an entry in the dishosts.conf file [WARN] Node 84 not reachable, but is an entry in the dishosts.conf file [WARN] Node 100 not reachable, but is an entry in the dishosts.conf file [WARN] Node 104 not reachable, but is an entry in the dishosts.conf file ************************ TOPOLOGY SEEN FROM ADAPTER 0 ************************ Adapters found: 19 ----- List of all nodes found: Nodes detected: 0004 0008 0012 0016 0020 0024 0028 0032 Nodes detected: 0036 0040 0044 0048 0052 0056 0060 0064 0088 0092 0096 ******************* INTERRUPT INFORMATION FOR ADAPTER NO 0 ******************* Interrupt counters for IX adapter 0: No of total interrupt ......................... : 55 No of doorbell interrupts ..................... : 0 No of message interrupts ...................... : 0 No of switch events ........................... : 55 No of slot up events .......................... : 0 No of slot down events ........................ : 0 No of uncorrectable slot error events ......... : 0 No of correctable slot error events ........... : 1 No of TLP throttle events ..................... : 0 No of completion timeout synthesis events ..... : 0 No of unclaimed interrupts .................... : 0 ************** INTERRUPT INFORMATION FOR ADAPTER NO 0 - LINK 0 ************** Interrupt counters for IX adapter 0 - Link 0: No of total interrupt ......................... : 0 No of link up events .......................... : 1 No of link down events ........................ : 1 No of uncorrectable link error events ......... : 6990 No of correctable link error events .......... : 4 ******** PCIe CABLE LINK ERROR INFORMATION FOR ADAPTER NO 0 - Link 0 ******** NACK error cnt - PCIe Cable Link 0 ............ : 0 NACK DLLP transmitted ......................: 0 NACK DLLP received .........................: 0 Uncorrectable error cnt - PCIe Cable Link 0 ... : 6990 dlperr cnt ................................ : 0 sdownerr cnt .............................. : 0 poisoned cnt .............................. : 0 fcperr cnt ................................ : 0 compto cnt ................................ : 0 cabort cnt ................................ : 0 uecomp cnt ................................ : 0 rcvovr cnt ................................ : 0 malformed cnt ............................. : 0 ecrc_cnt .................................. : 0 ur_cnt .................................... : 6990 acsv_cnt .................................. : 0 uie_cnt ................................... : 0 mcblktlp cnt .............................. : 0 atopeb cnt ................................ : 0 tlppbe cnt ................................ : 0 poisoned tlppbe cnt ....................... : 0 Correctable error cnt - PCIe Cable Link 0 ..... : 4 rcverr cnt ................................ : 4 badtlp cnt ................................ : 0 baddllp cnt ............................... : 0 rplyrovr cnt .............................. : 0 rplyto cnt ................................ : 0 advisorynf cnt ............................ : 0 cie cnt ................................... : 0 hlo cnt ................................... : 0 **************** PCIe SLOT ERROR INFORMATION FOR ADAPTER NO 0 **************** NACK error cnt - PCIe Slot .................... : 0 NACK DLLP transmitted ......................: 0 NACK DLLP received .........................: 0 Total uncorrectable error cnt - PCIe Slot ..... : 0 dlperr cnt ................................ : 0 sdownerr cnt .............................. : 0 poisoned cnt .............................. : 0 fcperr cnt ................................ : 0 compto cnt ................................ : 0 cabort cnt ................................ : 0 uecomp cnt ................................ : 0 rcvovr cnt ................................ : 0 malformed cnt ............................. : 0 ecrc_cnt .................................. : 0 ur_cnt .................................... : 0 acsv_cnt .................................. : 0 uie_cnt ................................... : 0 mcblktlp cnt .............................. : 0 atopeb cnt ................................ : 0 tlppbe cnt ................................ : 0 poisoned tlppbe cnt ....................... : 0 Total correctable error cnt - PCIe Slot ....... : 1 rcverr cnt ................................ : 1 badtlp cnt ................................ : 0 baddllp cnt ............................... : 1 rplyrovr cnt .............................. : 0 rplyto cnt ................................ : 0 advisorynf cnt ............................ : 0 cie cnt ................................... : 0 hlo cnt ................................... : 0 ********************** LINK RESET CNT FOR ADAPTER NO 0 ********************** Driver initialization : 0 Link check problems (RTG) : 0 Max link check attempts reached (RTG/FE) : 0 Fatal error detected : 0 Link watchdog failure : 0 IOCTL Enabled SCI link (IM) : 0 IOCTL Disable SCI link (IM) : 0 IOCTL Reset issued by user interface (IM) : 0 IOCTL Retrain issued by user interface (IM) : 0 IOCTL Prepare reconfiguration (IM) : 0 IOCTL Enable routing tables (IM) : 0 Stuck cable link : 0 Stuck link Serdes : 2654 Unexpected link width : 0 Unexpected link speed : 0 Generic test module : 0 Production test : 0 Power management : 0 ******************** LINK RESET HISTORY FOR ADAPTER NO 0 ******************** Reset reason[0] is the first occurrence ************************* DUMP OF ADAPTER NO 0 CSR'S ************************* Adapter 0: dump of CSR's in IXH chip VID, DID, offset 0x0000, has the value 0x8091111d PCICMD, PCISTS, offset 0x0004, has the value 0x00100507 RID, CCODE, offset 0x0008, has the value 0x06800002 CLS, LTIMER, HDR, BIST, offset 0x000c, has the value 0x00800008 BAR0, offset 0x0010, has the value 0xc4801000 BAR1, offset 0x0014, has the value 0x00000000 BAR2, offset 0x0018, has the value 0xf000000c BAR3, offset 0x001c, has the value 0x000039ff BAR4, offset 0x0020, has the value 0xc0000000 BAR5, offset 0x0024, has the value 0xc4000000 SUBVID, SUBID, offset 0x002c, has the value 0x161111c8 EROMBASE, offset 0x0030, has the value 0x00000000 CAPPTR, offset 0x0034, has the value 0x00000040 INTRLINE, INTRPIN, MAXLAT, offset 0x003c, has the value 0x0000010b PCIECAP, offset 0x0040, has the value 0x0002c010 PCIEDCAP, offset 0x0044, has the value 0x00008fe4 PCIEDCTL, offset 0x0048, has the value 0x000b593f PCIELCAP, offset 0x004c, has the value 0x00016c82 PCIELCTL, PCIELSTS, offset 0x0050, has the value 0x00820000 PCIEDCAP2, offset 0x0064, has the value 0x0000041f PCIEDCTL2, PCIEDSTS2, offset 0x0068, has the value 0x00000000 PCIELCAP2, offset 0x006c, has the value 0x00000000 PCIELCTL2, PCIELSTS2, offset 0x0070, has the value 0x00010000 PCICTL, offset 0x0078, has the value 0x00000000 SSIDSSVIDCAP, offset 0x00f0, has the value 0x0000000d SSIDSSVID, offset 0x00f4, has the value 0x161111c8 AERUES, offset 0x0104, has the value 0x00100000 SNUMCAP, offset 0x0180, has the value 0x20010003 SNUMLDW, offset 0x0184, has the value 0x000009ab SNUMUDW, offset 0x0188, has the value 0x00004345 PCIEVCECAP, offset 0x0200, has the value 0x00000000 NTCTL, offset 0x0400, has the value 0x00000003 NTINTSTS, offset 0x0404, has the value 0x00000000 NTINTMASK, offset 0x0408, has the value 0x00000070 NTSDATA, offset 0x040c, has the value 0x00000000 NTGSIGNAL, offset 0x0410, has the value 0x00000000 NTIERRORMASK0, offset 0x0414, has the value 0xffb80000 NTIERRORMASK1, offset 0x0418, has the value 0x01ffffff INDBELLSTS, offset 0x0428, has the value 0x00000000 INDBELLMSK, offset 0x042c, has the value 0x00000000 PTCCTL0, offset 0x0510, has the value 0x00000000 PTCCTL1, offset 0x0514, has the value 0x00000000 PTCDATA, offset 0x0518, has the value 0x00000000 PTCSTS, offset 0x051c, has the value 0x00000000 Adapter 0: dump of switch and status registers in IXH chip SWCTL, offset 0x0000, has the value 0x00190000 BCVSTS, offset 0x0004, has the value 0x00002582 PCLKMODE, offset 0x0008, has the value 0x00000101 SWPART0CTL, offset 0x0100, has the value 0x00000005 SWPART0STS, offset 0x0104, has the value 0x0000c120 SWPART1CTL, offset 0x0120, has the value 0x00000005 SWPART1STS, offset 0x0124, has the value 0x0000d123 SWPORT0CTL, offset 0x0200, has the value 0x00000007 SWPORT0STS, offset 0x0204, has the value 0x700001d3 SWPORT8CTL, offset 0x0300, has the value 0x00000018 SWPORT8STS, offset 0x0304, has the value 0x80000613 SESTS, offset 0x0c00, has the value 0x00000000 SEMSK, offset 0x0c04, has the value 0xfffefe30 SEPMSK, offset 0x0c08, has the value 0x00000000 SELINKUPSTS, offset 0x0c0c, has the value 0x00000000 SELINKUPMSK, offset 0x0c10, has the value 0x00fffefe SELINKDNSTS, offset 0x0c14, has the value 0x00000000 SELINKDNMSK, offset 0x0c18, has the value 0x00fffefe SEFRSTSTS, offset 0x0c1c, has the value 0x00000000 SEFRSTMSK, offset 0x0c20, has the value 0x000000ff SEFHSTSTS, offset 0x0c24, has the value 0x00000000 SEFHSTMSK, offset 0x0c28, has the value 0x000000ff SEGSIGSTS, offset 0x0c30, has the value 0x00000000 SEGSIGMSK, offset 0x0c34, has the value 0x000000ff SSIGNAL, offset 0x0c38, has the value 0x00000000 S4TXLCTL0, offset 0x1084, has the value 0x0004002e S4TXLCTL1, offset 0x1088, has the value 0xcad57860 S5TXLCTL0, offset 0x10a4, has the value 0x0004002e S5TXLCTL1, offset 0x10a8, has the value 0xcad57860 GPIOD, offset 0x1178, has the value 0x00000042 SMBUSSTS, offset 0x1188, has the value 0x2100a0ee GPECTL, offset 0x11b0, has the value 0x00000000 GPESTS, offset 0x11b4, has the value 0x00000000 TMPCTL, offset 0x11d4, has the value 0x00000000 TMPSTS, offset 0x11d8, has the value 0xaa8e4482 *********************** SESSION STATUS FROM ADAPTER 0 *********************** Currently no sessions detected ************************* DUMP OF IRM CONFIG SETTING ************************* impl_session : TRUE dmaAllowed : TRUE ccoherprop : TRUE stampSize : 0 linkMessagesEnabled : TRUE linkMessagesEnabled : TRUE maxVcNumber : 2048 useNonBlockBarriers : TRUE notesOnLogFileOnly : FALSE linkWatchdogMaxRetries : 1 linkWatchdogPeriod : 3 readyToGoDelay : 200 useOsConfig : FALSE IRM Config : 0x3302 PSB Config : 0x8 LC Config : 0x1 Memory Pre-Alloc Size : 0 MB Disable force link training : 0 Min link width : x8 Min link speed : Gen2 Interrupt polling : Immediate (1000, 100) DMA polling : Immediate (1000, 100) ---------------------------------- dis_diag discovered 0 note(s). dis_diag discovered 7 warning(s). dis_diag discovered 0 error(s). TEST RESULT: *PASSED*