guardctrl log -a "2025-02-02 16:08:00 UTC" -b "2025-02-02 16:10:00 UTC" SQZ_MANAGER 2025-02-02_16:08:01.949482Z SQZ_MANAGER REQUEST: RESET_SQZ_ASC_FDS 2025-02-02_16:08:01.950008Z SQZ_MANAGER calculating path: FREQ_DEP_SQZ->RESET_SQZ_ASC_FDS 2025-02-02_16:08:01.950008Z SQZ_MANAGER new target: RESET_SQZ_ASC_FDS 2025-02-02_16:08:42.439020Z SQZ_MANAGER EDGE: FREQ_DEP_SQZ->RESET_SQZ_ASC_FDS 2025-02-02_16:08:42.439991Z SQZ_MANAGER calculating path: RESET_SQZ_ASC_FDS->RESET_SQZ_ASC_FDS 2025-02-02_16:08:42.451368Z SQZ_MANAGER executing state: RESET_SQZ_ASC_FDS (97) 2025-02-02_16:08:42.451956Z SQZ_MANAGER [RESET_SQZ_ASC_FDS.main] Stopping SQZ_ANG_ADJUST 2025-02-02_16:08:42.453924Z SQZ_MANAGER [RESET_SQZ_ASC_FDS.main] ezca: H1:GRD-SQZ_ANG_ADJUST_REQUEST => DOWN 2025-02-02_16:08:42.455586Z SQZ_MANAGER [RESET_SQZ_ASC_FDS.main] turning off SQZ AS42 ASC 2025-02-02_16:08:42.456239Z SQZ_MANAGER [RESET_SQZ_ASC_FDS.main] ezca: H1:SQZ-ASC_WFS_SWITCH => 0 2025-02-02_16:08:42.456239Z SQZ_MANAGER [RESET_SQZ_ASC_FDS.main] gracefully clearing SQZ AS42 ASC 2025-02-02_16:08:42.457183Z SQZ_MANAGER [RESET_SQZ_ASC_FDS.main] ezca: H1:SQZ-ASC_POS_P_TRAMP => 2 2025-02-02_16:08:42.457767Z SQZ_MANAGER [RESET_SQZ_ASC_FDS.main] ezca: H1:SQZ-ASC_POS_P_GAIN => 0 2025-02-02_16:08:42.458464Z SQZ_MANAGER [RESET_SQZ_ASC_FDS.main] ezca: H1:SQZ-ASC_ANG_P_TRAMP => 2 2025-02-02_16:08:42.458959Z SQZ_MANAGER [RESET_SQZ_ASC_FDS.main] ezca: H1:SQZ-ASC_ANG_P_GAIN => 0 2025-02-02_16:08:42.459475Z SQZ_MANAGER [RESET_SQZ_ASC_FDS.main] ezca: H1:SQZ-ASC_POS_Y_TRAMP => 2 2025-02-02_16:08:42.460083Z SQZ_MANAGER [RESET_SQZ_ASC_FDS.main] ezca: H1:SQZ-ASC_POS_Y_GAIN => 0 2025-02-02_16:08:42.460406Z SQZ_MANAGER [RESET_SQZ_ASC_FDS.main] ezca: H1:SQZ-ASC_ANG_Y_TRAMP => 2 2025-02-02_16:08:42.460799Z SQZ_MANAGER [RESET_SQZ_ASC_FDS.main] ezca: H1:SQZ-ASC_ANG_Y_GAIN => 0 2025-02-02_16:08:42.461842Z SQZ_MANAGER [RESET_SQZ_ASC_FDS.main] ezca: H1:SUS-ZM4_M1_LOCK_P_GAIN => 0 2025-02-02_16:08:42.462586Z SQZ_MANAGER [RESET_SQZ_ASC_FDS.main] ezca: H1:SUS-ZM4_M1_LOCK_Y_GAIN => 0 2025-02-02_16:08:42.463284Z SQZ_MANAGER [RESET_SQZ_ASC_FDS.main] ezca: H1:SUS-ZM5_M1_LOCK_P_GAIN => 0 2025-02-02_16:08:42.463904Z SQZ_MANAGER [RESET_SQZ_ASC_FDS.main] ezca: H1:SUS-ZM5_M1_LOCK_Y_GAIN => 0 2025-02-02_16:08:44.465192Z SQZ_MANAGER [RESET_SQZ_ASC_FDS.main] ezca: H1:SQZ-ASC_POS_P_RSET => 2 2025-02-02_16:08:44.465666Z SQZ_MANAGER [RESET_SQZ_ASC_FDS.main] ezca: H1:SQZ-ASC_POS_P_TRAMP => 1 2025-02-02_16:08:44.465972Z SQZ_MANAGER [RESET_SQZ_ASC_FDS.main] ezca: H1:SQZ-ASC_POS_P_GAIN => 1 2025-02-02_16:08:44.466287Z SQZ_MANAGER [RESET_SQZ_ASC_FDS.main] ezca: H1:SQZ-ASC_ANG_P_RSET => 2 2025-02-02_16:08:44.466615Z SQZ_MANAGER [RESET_SQZ_ASC_FDS.main] ezca: H1:SQZ-ASC_ANG_P_TRAMP => 1 2025-02-02_16:08:44.466945Z SQZ_MANAGER [RESET_SQZ_ASC_FDS.main] ezca: H1:SQZ-ASC_ANG_P_GAIN => 1 2025-02-02_16:08:44.467237Z SQZ_MANAGER [RESET_SQZ_ASC_FDS.main] ezca: H1:SQZ-ASC_POS_Y_RSET => 2 2025-02-02_16:08:44.467645Z SQZ_MANAGER [RESET_SQZ_ASC_FDS.main] ezca: H1:SQZ-ASC_POS_Y_TRAMP => 1 2025-02-02_16:08:44.468132Z SQZ_MANAGER [RESET_SQZ_ASC_FDS.main] ezca: H1:SQZ-ASC_POS_Y_GAIN => 1 2025-02-02_16:08:44.468446Z SQZ_MANAGER [RESET_SQZ_ASC_FDS.main] ezca: H1:SQZ-ASC_ANG_Y_RSET => 2 2025-02-02_16:08:44.468905Z SQZ_MANAGER [RESET_SQZ_ASC_FDS.main] ezca: H1:SQZ-ASC_ANG_Y_TRAMP => 1 2025-02-02_16:08:44.469255Z SQZ_MANAGER [RESET_SQZ_ASC_FDS.main] ezca: H1:SQZ-ASC_ANG_Y_GAIN => 1 2025-02-02_16:08:44.469686Z SQZ_MANAGER [RESET_SQZ_ASC_FDS.main] ezca: H1:SUS-ZM4_M1_LOCK_P_RSET => 2 2025-02-02_16:08:44.470249Z SQZ_MANAGER [RESET_SQZ_ASC_FDS.main] ezca: H1:SUS-ZM4_M1_LOCK_P_GAIN => 1 2025-02-02_16:08:44.470516Z SQZ_MANAGER [RESET_SQZ_ASC_FDS.main] ezca: H1:SUS-ZM4_M1_LOCK_Y_RSET => 2 2025-02-02_16:08:44.471082Z SQZ_MANAGER [RESET_SQZ_ASC_FDS.main] ezca: H1:SUS-ZM4_M1_LOCK_Y_GAIN => 1 2025-02-02_16:08:44.471377Z SQZ_MANAGER [RESET_SQZ_ASC_FDS.main] ezca: H1:SUS-ZM5_M1_LOCK_P_RSET => 2 2025-02-02_16:08:44.471939Z SQZ_MANAGER [RESET_SQZ_ASC_FDS.main] ezca: H1:SUS-ZM5_M1_LOCK_P_GAIN => 1 2025-02-02_16:08:44.472224Z SQZ_MANAGER [RESET_SQZ_ASC_FDS.main] ezca: H1:SUS-ZM5_M1_LOCK_Y_RSET => 2 2025-02-02_16:08:44.472773Z SQZ_MANAGER [RESET_SQZ_ASC_FDS.main] ezca: H1:SUS-ZM5_M1_LOCK_Y_GAIN => 1 2025-02-02_16:08:44.472864Z SQZ_MANAGER [RESET_SQZ_ASC_FDS.main] done 2025-02-02_16:08:59.395795Z SQZ_MANAGER REQUEST: RESET_SQZ_ANG_FDS 2025-02-02_16:08:59.396277Z SQZ_MANAGER calculating path: RESET_SQZ_ASC_FDS->RESET_SQZ_ANG_FDS 2025-02-02_16:08:59.396463Z SQZ_MANAGER new target: SQZ_ASC_FDS 2025-02-02_16:08:59.446806Z SQZ_MANAGER EDGE: RESET_SQZ_ASC_FDS->SQZ_ASC_FDS 2025-02-02_16:08:59.452012Z SQZ_MANAGER calculating path: SQZ_ASC_FDS->RESET_SQZ_ANG_FDS 2025-02-02_16:08:59.452503Z SQZ_MANAGER new target: FREQ_DEP_SQZ 2025-02-02_16:08:59.454159Z SQZ_MANAGER executing state: SQZ_ASC_FDS (65) 2025-02-02_16:08:59.458734Z SQZ_MANAGER [SQZ_ASC_FDS.enter] 2025-02-02_16:08:59.460493Z SQZ_MANAGER [SQZ_ASC_FDS.main] ezca: H1:SQZ-ASC_WFS_SWITCH => 1 2025-02-02_16:08:59.460885Z SQZ_MANAGER [SQZ_ASC_FDS.main] timer['pause'] = 2 2025-02-02_16:09:01.461061Z SQZ_MANAGER [SQZ_ASC_FDS.run] timer['pause'] done 2025-02-02_16:09:01.510115Z SQZ_MANAGER [SQZ_ASC_FDS.run] engaged SQZ ASC 2025-02-02_16:09:01.630690Z SQZ_MANAGER EDGE: SQZ_ASC_FDS->FREQ_DEP_SQZ 2025-02-02_16:09:01.631665Z SQZ_MANAGER calculating path: FREQ_DEP_SQZ->RESET_SQZ_ANG_FDS 2025-02-02_16:09:01.633536Z SQZ_MANAGER new target: RESET_SQZ_ANG_FDS 2025-02-02_16:09:01.635199Z SQZ_MANAGER executing state: FREQ_DEP_SQZ (100) 2025-02-02_16:09:01.636938Z SQZ_MANAGER [FREQ_DEP_SQZ.enter] 2025-02-02_16:09:01.711464Z SQZ_MANAGER [FREQ_DEP_SQZ.run] ezca: H1:GRD-SQZ_ANG_ADJUST_REQUEST => ADJUST_SQZ_ANG_ADF 2025-02-02_16:09:02.197763Z SQZ_MANAGER EDGE: FREQ_DEP_SQZ->RESET_SQZ_ANG_FDS 2025-02-02_16:09:02.202704Z SQZ_MANAGER calculating path: RESET_SQZ_ANG_FDS->RESET_SQZ_ANG_FDS 2025-02-02_16:09:02.204120Z SQZ_MANAGER executing state: RESET_SQZ_ANG_FDS (91) 2025-02-02_16:09:02.206860Z SQZ_MANAGER [RESET_SQZ_ANG_FDS.main] timer['wait'] done 2025-02-02_16:09:02.207329Z SQZ_MANAGER [RESET_SQZ_ANG_FDS.main] timer['wait'] = 0 2025-02-02_16:09:02.207482Z SQZ_MANAGER [RESET_SQZ_ANG_FDS.main] Stopping SQZ_ANG_ADJUST 2025-02-02_16:09:02.208727Z SQZ_MANAGER [RESET_SQZ_ANG_FDS.main] ezca: H1:GRD-SQZ_ANG_ADJUST_REQUEST => DOWN 2025-02-02_16:09:02.268482Z SQZ_MANAGER [RESET_SQZ_ANG_FDS.run] USERMSG 0: Wating 60 seconds before going back to FDS. 2025-02-02_16:09:02.270869Z SQZ_MANAGER W: Traceback (most recent call last): 2025-02-02_16:09:02.270869Z File "/usr/lib/python3/dist-packages/guardian/worker.py", line 494, in run 2025-02-02_16:09:02.270869Z retval = statefunc() 2025-02-02_16:09:02.270869Z File "/usr/lib/python3/dist-packages/guardian/state.py", line 246, in __call__ 2025-02-02_16:09:02.270869Z main_return = self.func.__call__(state_obj, *args, **kwargs) 2025-02-02_16:09:02.270869Z File "/usr/lib/python3/dist-packages/guardian/state.py", line 246, in __call__ 2025-02-02_16:09:02.270869Z main_return = self.func.__call__(state_obj, *args, **kwargs) 2025-02-02_16:09:02.270869Z File "/usr/lib/python3/dist-packages/guardian/state.py", line 246, in __call__ 2025-02-02_16:09:02.270869Z main_return = self.func.__call__(state_obj, *args, **kwargs) 2025-02-02_16:09:02.270869Z [Previous line repeated 1 more time] 2025-02-02_16:09:02.270869Z File "/opt/rtcds/userapps/release/sqz/h1/guardian/SQZ_MANAGER.py", line 863, in run 2025-02-02_16:09:02.270869Z if self['wait']: 2025-02-02_16:09:02.270869Z TypeError: 'RESET_SQZ_ANG' object is not subscriptable 2025-02-02_16:09:02.271925Z SQZ_MANAGER [RESET_SQZ_ANG_FDS.run] USERMSG 1: USER CODE ERROR (see log) 2025-02-02_16:09:02.326734Z SQZ_MANAGER ERROR in state RESET_SQZ_ANG_FDS: see log for more info (LOAD to reset) 2025-02-02_16:09:34.758013Z SQZ_MANAGER MODE: MANUAL 2025-02-02_16:09:34.761968Z SQZ_MANAGER MANAGER: removed 2025-02-02_16:09:40.017463Z SQZ_MANAGER MODE: AUTO 2025-02-02_16:09:51.041070Z SQZ_MANAGER MODE: MANUAL