PDT: 2025-06-05 16:14:58.755364 PDT UTC: 2025-06-05 23:14:58.755364 UTC GPS: 1433200516.755364 2025-06-05 23:14:59,761 | INFO | File written out to: /ligo/groups/cal/H1/measurements/DARMOLG_SS/DARMOLG_SS_20250605T231459Z.hdf5 2025-06-05 23:14:59,771 | INFO | File written out to: /ligo/groups/cal/H1/measurements/PCALY2DARM_SS/PCALY2DARM_SS_20250605T231459Z.hdf5 2025-06-05 23:14:59,776 | INFO | File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_L1_SS/SUSETMX_L1_SS_20250605T231459Z.hdf5 2025-06-05 23:14:59,780 | INFO | File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_L2_SS/SUSETMX_L2_SS_20250605T231459Z.hdf5 2025-06-05 23:14:59,785 | INFO | File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_L3_SS/SUSETMX_L3_SS_20250605T231459Z.hdf5 2025-06-05 23:14:59,785 | INFO | Overall driving parameters: 2025-06-05 23:14:59,785 | INFO | Preparing to scan the following sweeps ['DARM_OLGTF', 'PCALY2DARMTF', 'L1_SUSETMX_iEXC2DARMTF', 'L2_SUSETMX_iEXC2DARMTF', 'L3_SUSETMX_iEXC2DARMTF'] 2025-06-05 23:14:59,785 | INFO | With parameters: BW: 0.14; DrivingCycles: 40; MinDriveTime: 3; Averages: 5; Overlap: 0; RampUpTime: 3; RampDownTime: 3; SettleTimePercent: 10; ScanTime: 1229 2025-06-05 23:14:59,785 | INFO | For DARM_OLGTF, prepaing EXC: H1:LSC-DARM1_EXC; A: ['H1:LSC-DARM1_IN2', 'H1:LSC-DARM1_EXC']; B: ['H1:LSC-DARM1_IN1', 'H1:LSC-DARM1_IN2'] 2025-06-05 23:14:59,787 | INFO | For PCALY2DARMTF, prepaing EXC: H1:CAL-PCALY_SWEPT_SINE_EXC; A: ['H1:CAL-PCALY_RX_PD_OUT_DQ', 'H1:CAL-PCALY_RX_PD_OUT_DQ', 'H1:CAL-PCALY_TX_PD_OUT_DQ']; B: ['H1:CAL-DELTAL_EXTERNAL_DQ', 'H1:LSC-DARM_IN1_DQ', 'H1:LSC-DARM_IN1_DQ'] 2025-06-05 23:14:59,789 | INFO | For L1_SUSETMX_iEXC2DARMTF, prepaing EXC: H1:SUS-ETMX_L1_CAL_EXC; A: ['H1:SUS-ETMX_L1_CAL_EXC']; B: ['H1:LSC-DARM_IN1_DQ'] 2025-06-05 23:14:59,791 | INFO | For L2_SUSETMX_iEXC2DARMTF, prepaing EXC: H1:SUS-ETMX_L2_CAL_EXC; A: ['H1:SUS-ETMX_L2_CAL_EXC']; B: ['H1:LSC-DARM_IN1_DQ'] 2025-06-05 23:14:59,792 | INFO | For L3_SUSETMX_iEXC2DARMTF, prepaing EXC: H1:SUS-ETMX_L3_CAL_EXC; A: ['H1:SUS-ETMX_L3_CAL_EXC']; B: ['H1:LSC-DARM_IN1_DQ'] 2025-06-05 23:14:59,808 | INFO | Start data collection while monitoring 5 processes 2025-06-05 23:15:10,811 | INFO | Scanning frequency 12.86 in Scan : L1_SUSETMX_iEXC2DARMTF on PID: 1152087 2025-06-05 23:15:10,812 | INFO | Drive, on L1_SUSETMX_iEXC2DARMTF, at frequency: 12.86, is now running for 24 seconds. 2025-06-05 23:15:10,812 | INFO | Scanning frequency 5.6 in Scan : DARM_OLGTF on PID: 1152080 2025-06-05 23:15:10,812 | INFO | Drive, on DARM_OLGTF, at frequency: 5.6, is now running for 44 seconds. 2025-06-05 23:15:10,813 | INFO | Scanning frequency 7.97 in Scan : PCALY2DARMTF on PID: 1152084 2025-06-05 23:15:10,813 | INFO | Drive, on PCALY2DARMTF, at frequency: 7.97, is now running for 34 seconds. testpoint_client 1.0.0 ndshosts: h1daqnds1 and h1daqnds0 getting host by name: h1daqnds1 found host 2025-06-05 23:15:10,815 | INFO | Scanning frequency 51.05 in Scan : L2_SUSETMX_iEXC2DARMTF on PID: 1152090 2025-06-05 23:15:10,815 | INFO | Scanning frequency 289.84 in Scan : L3_SUSETMX_iEXC2DARMTF on PID: 1152093 2025-06-05 23:15:10,815 | INFO | Drive, on L2_SUSETMX_iEXC2DARMTF, at frequency: 51.05, is now running for 23 seconds. 2025-06-05 23:15:10,816 | INFO | Drive, on L3_SUSETMX_iEXC2DARMTF, at frequency: 289.84, is now running for 23 seconds. found version 4 or newer test point interface testpoint_client 1.0.0 ndshosts: h1daqnds1 and h1daqnds0 getting host by name: h1daqnds1 found host found version 4 or newer test point interface testpoint_client 1.0.0 ndshosts: h1daqnds1 and h1daqnds0 getting host by name: h1daqnds1 found host found version 4 or newer test point interface testpoint_client 1.0.0 ndshosts: h1daqnds1 and h1daqnds0 getting host by name: h1daqnds1 found host found version 4 or newer test point interface testpoint_client 1.0.0 ndshosts: h1daqnds1 and h1daqnds0 getting host by name: h1daqnds1 found host found version 4 or newer test point interface 2025-06-05 23:15:46,910 | INFO | Drive, on L2_SUSETMX_iEXC2DARMTF, at frequency: 51.05, and amplitude 0.34489, is finished. GPS start and end time stamps: 1433200545, 1433200560 2025-06-05 23:15:46,911 | INFO | Scanning frequency 64.78 in Scan : L2_SUSETMX_iEXC2DARMTF on PID: 1152090 2025-06-05 23:15:46,911 | INFO | Drive, on L2_SUSETMX_iEXC2DARMTF, at frequency: 64.78, is now running for 23 seconds. 2025-06-05 23:15:48,015 | INFO | Drive, on L3_SUSETMX_iEXC2DARMTF, at frequency: 289.84, and amplitude 0.49024, is finished. GPS start and end time stamps: 1433200545, 1433200560 2025-06-05 23:15:48,015 | INFO | Scanning frequency 339.4 in Scan : L3_SUSETMX_iEXC2DARMTF on PID: 1152093 2025-06-05 23:15:48,015 | INFO | Drive, on L3_SUSETMX_iEXC2DARMTF, at frequency: 339.4, is now running for 23 seconds. 2025-06-05 23:15:49,131 | INFO | Drive, on L1_SUSETMX_iEXC2DARMTF, at frequency: 12.86, and amplitude 19.723, is finished. GPS start and end time stamps: 1433200545, 1433200561 2025-06-05 23:15:49,132 | INFO | Scanning frequency 14.44 in Scan : L1_SUSETMX_iEXC2DARMTF on PID: 1152087 2025-06-05 23:15:49,132 | INFO | Drive, on L1_SUSETMX_iEXC2DARMTF, at frequency: 14.44, is now running for 23 seconds. 2025-06-05 23:15:57,896 | INFO | Drive, on PCALY2DARMTF, at frequency: 7.97, and amplitude 14881.0, is finished. GPS start and end time stamps: 1433200545, 1433200571 2025-06-05 23:15:57,896 | INFO | Scanning frequency 8.31 in Scan : PCALY2DARMTF on PID: 1152084 2025-06-05 23:15:57,897 | INFO | Drive, on PCALY2DARMTF, at frequency: 8.31, is now running for 33 seconds. 2025-06-05 23:16:07,921 | INFO | Drive, on DARM_OLGTF, at frequency: 5.6, and amplitude 1.5e-07, is finished. GPS start and end time stamps: 1433200545, 1433200581 2025-06-05 23:16:07,921 | INFO | Scanning frequency 6.01 in Scan : DARM_OLGTF on PID: 1152080 2025-06-05 23:16:07,921 | INFO | Drive, on DARM_OLGTF, at frequency: 6.01, is now running for 42 seconds. 2025-06-05 23:16:12,997 | INFO | Drive, on L2_SUSETMX_iEXC2DARMTF, at frequency: 64.78, and amplitude 0.55147, is finished. GPS start and end time stamps: 1433200571, 1433200586 2025-06-05 23:16:12,997 | INFO | Scanning frequency 70.0 in Scan : L2_SUSETMX_iEXC2DARMTF on PID: 1152090 2025-06-05 23:16:12,998 | INFO | Drive, on L2_SUSETMX_iEXC2DARMTF, at frequency: 70.0, is now running for 23 seconds. 2025-06-05 23:16:14,127 | INFO | Drive, on L3_SUSETMX_iEXC2DARMTF, at frequency: 339.4, and amplitude 0.48665, is finished. GPS start and end time stamps: 1433200571, 1433200586 2025-06-05 23:16:14,127 | INFO | Scanning frequency 397.44 in Scan : L3_SUSETMX_iEXC2DARMTF on PID: 1152093 2025-06-05 23:16:14,127 | INFO | Drive, on L3_SUSETMX_iEXC2DARMTF, at frequency: 397.44, is now running for 23 seconds. 2025-06-05 23:16:15,249 | INFO | Drive, on L1_SUSETMX_iEXC2DARMTF, at frequency: 14.44, and amplitude 31.038, is finished. GPS start and end time stamps: 1433200571, 1433200586 2025-06-05 23:16:15,249 | INFO | Scanning frequency 15.6 in Scan : L1_SUSETMX_iEXC2DARMTF on PID: 1152087 2025-06-05 23:16:15,249 | INFO | Drive, on L1_SUSETMX_iEXC2DARMTF, at frequency: 15.6, is now running for 23 seconds. 2025-06-05 23:16:18,901 | ERROR | IFO not in Low Noise state, Sending Interrupts to excitations and main thread. 2025-06-05 23:16:18,902 | ERROR | Ramping Down Excitation on channel H1:SUS-ETMX_L3_CAL_EXC 2025-06-05 23:16:18,902 | ERROR | Ramping Down Excitation on channel H1:CAL-PCALY_SWEPT_SINE_EXC 2025-06-05 23:16:18,902 | ERROR | Ramping Down Excitation on channel H1:SUS-ETMX_L2_CAL_EXC 2025-06-05 23:16:18,902 | ERROR | Ramping Down Excitation on channel H1:LSC-DARM1_EXC 2025-06-05 23:16:18,902 | ERROR | Ramping Down Excitation on channel H1:SUS-ETMX_L1_CAL_EXC 2025-06-05 23:16:18,902 | ERROR | Aborting main thread and Data recording, if any. Cleaning up temporary file structure. PDT: 2025-06-05 16:16:23.262386 PDT UTC: 2025-06-05 23:16:23.262386 UTC GPS: 1433200601.262386