2025-06-11_03:19:36.276724Z ISC_LOCK executing state: LOWNOISE_ASC (522) 2025-06-11_03:19:36.277086Z ISC_LOCK [LOWNOISE_ASC.enter] 2025-06-11_03:19:36.285892Z ISC_LOCK [LOWNOISE_ASC.main] ezca: H1:ASC-ADS_PIT3_OSC_CLKGAIN => 300 2025-06-11_03:19:36.286543Z ISC_LOCK [LOWNOISE_ASC.main] ezca: H1:ASC-ADS_PIT4_OSC_CLKGAIN => 300 2025-06-11_03:19:36.286950Z ISC_LOCK [LOWNOISE_ASC.main] ezca: H1:ASC-ADS_PIT5_OSC_CLKGAIN => 300 2025-06-11_03:19:36.287428Z ISC_LOCK [LOWNOISE_ASC.main] ezca: H1:ASC-ADS_YAW3_OSC_CLKGAIN => 300 2025-06-11_03:19:36.287921Z ISC_LOCK [LOWNOISE_ASC.main] ezca: H1:ASC-ADS_YAW4_OSC_CLKGAIN => 300 2025-06-11_03:19:36.288282Z ISC_LOCK [LOWNOISE_ASC.main] ezca: H1:ASC-ADS_YAW5_OSC_CLKGAIN => 300 2025-06-11_03:19:36.288725Z ISC_LOCK [LOWNOISE_ASC.main] timer['LoopShapeRamp'] = 5 2025-06-11_03:19:36.289130Z ISC_LOCK [LOWNOISE_ASC.main] timer['pwr'] = 0.125 2025-06-11_03:19:36.414329Z ISC_LOCK [LOWNOISE_ASC.run] timer['pwr'] done 2025-06-11_03:19:41.288814Z ISC_LOCK [LOWNOISE_ASC.run] timer['LoopShapeRamp'] done 2025-06-11_03:19:41.347187Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:ASC-CHARD_Y_GAIN => 200 2025-06-11_03:19:41.348463Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:ASC-CHARD_Y_SW1 => 256 2025-06-11_03:19:41.474295Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:ASC-CHARD_Y_SW2 => 20 2025-06-11_03:19:41.599723Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:ASC-CHARD_Y => ON: FM3, FM8, FM9 2025-06-11_03:19:41.600563Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:ASC-DHARD_Y_SW1 => 5392 2025-06-11_03:19:41.726387Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:ASC-DHARD_Y_SW2 => 4 2025-06-11_03:19:41.851873Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:ASC-DHARD_Y => ON: FM1, FM3, FM4, FM5, FM8 2025-06-11_03:19:41.852458Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:ASC-CSOFT_P_SMOOTH_ENABLE => 0 2025-06-11_03:19:41.852884Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:ASC-CSOFT_Y_SMOOTH_ENABLE => 0 2025-06-11_03:19:41.853244Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:ASC-DSOFT_P_SMOOTH_ENABLE => 0 2025-06-11_03:19:41.853555Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:ASC-DSOFT_Y_SMOOTH_ENABLE => 0 2025-06-11_03:19:41.853790Z ISC_LOCK [LOWNOISE_ASC.run] timer['LoopShapeRamp'] = 10 2025-06-11_03:19:51.854029Z ISC_LOCK [LOWNOISE_ASC.run] timer['LoopShapeRamp'] done 2025-06-11_03:19:51.901592Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:ASC-CHARD_P_TRAMP => 5 2025-06-11_03:19:52.028052Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:ASC-CHARD_P_SW2 => 16 2025-06-11_03:19:52.153477Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:ASC-CHARD_P => OFF: FM9 2025-06-11_03:19:52.154305Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:ASC-CHARD_P_SW1 => 256 2025-06-11_03:19:52.280086Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:ASC-CHARD_P_SW2 => 4 2025-06-11_03:19:52.405417Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:ASC-CHARD_P => ON: FM3, FM8 2025-06-11_03:19:52.405840Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:ASC-CHARD_P_GAIN => 208 2025-06-11_03:19:52.406077Z ISC_LOCK [LOWNOISE_ASC.run] timer['LoopShapeRamp'] = 5 2025-06-11_03:19:57.406232Z ISC_LOCK [LOWNOISE_ASC.run] timer['LoopShapeRamp'] done 2025-06-11_03:19:57.464904Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:ASC-DSOFT_Y_TRAMP => 5 2025-06-11_03:19:57.465234Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:ASC-DSOFT_Y_GAIN => 5 2025-06-11_03:19:57.465910Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:ASC-CSOFT_P_GAIN => 20 2025-06-11_03:19:57.466497Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:ASC-DSOFT_P_GAIN => 5 2025-06-11_03:19:57.466801Z ISC_LOCK [LOWNOISE_ASC.run] timer['LoopShapeRamp'] = 5 2025-06-11_03:20:02.467350Z ISC_LOCK [LOWNOISE_ASC.run] timer['LoopShapeRamp'] done 2025-06-11_03:20:02.468010Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:SUS-ITMX_M0_DAMP_Y_TRAMP => 10 2025-06-11_03:20:02.468487Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:SUS-ETMX_M0_DAMP_Y_TRAMP => 10 2025-06-11_03:20:02.468925Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:SUS-ITMY_M0_DAMP_Y_TRAMP => 10 2025-06-11_03:20:02.469596Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:SUS-ITMX_M0_DAMP_Y_GAIN => -0.5 2025-06-11_03:20:02.469946Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:SUS-ETMX_M0_DAMP_Y_GAIN => -0.5 2025-06-11_03:20:02.470289Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:SUS-ITMY_M0_DAMP_Y_GAIN => -0.5 2025-06-11_03:20:02.470695Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:SUS-ETMY_M0_DAMP_Y_GAIN => -0.5 2025-06-11_03:20:02.470929Z ISC_LOCK [LOWNOISE_ASC.run] timer['LoopShapeRamp'] = 10 2025-06-11_03:20:12.471090Z ISC_LOCK [LOWNOISE_ASC.run] timer['LoopShapeRamp'] done 2025-06-11_03:20:12.528671Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:SUS-SR2_M1_DAMP_P_GAIN => -0.2 2025-06-11_03:20:12.528950Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:SUS-SR2_M1_DAMP_Y_GAIN => -0.2 2025-06-11_03:20:12.529214Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:SUS-SR2_M1_DAMP_L_GAIN => -0.2 2025-06-11_03:20:12.529574Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:SUS-SR2_M1_DAMP_R_GAIN => -0.2 2025-06-11_03:20:12.529806Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:SUS-SR2_M1_DAMP_T_GAIN => -0.2 2025-06-11_03:20:12.530065Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:SUS-SR2_M1_DAMP_V_GAIN => -0.2 2025-06-11_03:20:12.530291Z ISC_LOCK [LOWNOISE_ASC.run] timer['LoopShapeRamp'] = 10 2025-06-11_03:20:22.530430Z ISC_LOCK [LOWNOISE_ASC.run] timer['LoopShapeRamp'] done 2025-06-11_03:20:22.531673Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:ASC-DHARD_P_SW1 => 1024 2025-06-11_03:20:22.782742Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:ASC-DHARD_P => ON: FM4 2025-06-11_03:20:22.782960Z ISC_LOCK [LOWNOISE_ASC.run] timer['LoopShapeRamp'] = 5 2025-06-11_03:20:23.213314Z ISC_LOCK [LOWNOISE_ASC.run] Unstalling IMC_LOCK 2025-06-11_03:20:23.456998Z ISC_LOCK JUMP target: LOCKLOSS