2025-06-11_04:48:08.837035Z ISC_LOCK executing state: LOWNOISE_ASC (522) 2025-06-11_04:48:08.837412Z ISC_LOCK [LOWNOISE_ASC.enter] 2025-06-11_04:48:08.846780Z ISC_LOCK [LOWNOISE_ASC.main] ezca: H1:ASC-ADS_PIT3_OSC_CLKGAIN => 300 2025-06-11_04:48:08.847113Z ISC_LOCK [LOWNOISE_ASC.main] ezca: H1:ASC-ADS_PIT4_OSC_CLKGAIN => 300 2025-06-11_04:48:08.847399Z ISC_LOCK [LOWNOISE_ASC.main] ezca: H1:ASC-ADS_PIT5_OSC_CLKGAIN => 300 2025-06-11_04:48:08.847727Z ISC_LOCK [LOWNOISE_ASC.main] ezca: H1:ASC-ADS_YAW3_OSC_CLKGAIN => 300 2025-06-11_04:48:08.848129Z ISC_LOCK [LOWNOISE_ASC.main] ezca: H1:ASC-ADS_YAW4_OSC_CLKGAIN => 300 2025-06-11_04:48:08.848409Z ISC_LOCK [LOWNOISE_ASC.main] ezca: H1:ASC-ADS_YAW5_OSC_CLKGAIN => 300 2025-06-11_04:48:08.848618Z ISC_LOCK [LOWNOISE_ASC.main] timer['LoopShapeRamp'] = 5 2025-06-11_04:48:08.848789Z ISC_LOCK [LOWNOISE_ASC.main] timer['pwr'] = 0.125 2025-06-11_04:48:08.974108Z ISC_LOCK [LOWNOISE_ASC.run] timer['pwr'] done 2025-06-11_04:48:13.848815Z ISC_LOCK [LOWNOISE_ASC.run] timer['LoopShapeRamp'] done 2025-06-11_04:48:13.904597Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:ASC-CHARD_Y_GAIN => 200 2025-06-11_04:48:13.905193Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:ASC-CHARD_Y_SW1 => 256 2025-06-11_04:48:14.031028Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:ASC-CHARD_Y_SW2 => 20 2025-06-11_04:48:14.156369Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:ASC-CHARD_Y => ON: FM3, FM8, FM9 2025-06-11_04:48:14.157178Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:ASC-DHARD_Y_SW1 => 5392 2025-06-11_04:48:14.283009Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:ASC-DHARD_Y_SW2 => 4 2025-06-11_04:48:14.408349Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:ASC-DHARD_Y => ON: FM1, FM3, FM4, FM5, FM8 2025-06-11_04:48:14.408861Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:ASC-CSOFT_P_SMOOTH_ENABLE => 0 2025-06-11_04:48:14.409248Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:ASC-CSOFT_Y_SMOOTH_ENABLE => 0 2025-06-11_04:48:14.409606Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:ASC-DSOFT_P_SMOOTH_ENABLE => 0 2025-06-11_04:48:14.409975Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:ASC-DSOFT_Y_SMOOTH_ENABLE => 0 2025-06-11_04:48:14.410171Z ISC_LOCK [LOWNOISE_ASC.run] timer['LoopShapeRamp'] = 10 2025-06-11_04:48:24.410337Z ISC_LOCK [LOWNOISE_ASC.run] timer['LoopShapeRamp'] done 2025-06-11_04:48:24.462714Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:ASC-CHARD_P_TRAMP => 5 2025-06-11_04:48:24.589161Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:ASC-CHARD_P_SW2 => 16 2025-06-11_04:48:24.714616Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:ASC-CHARD_P => OFF: FM9 2025-06-11_04:48:24.715676Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:ASC-CHARD_P_SW1 => 256 2025-06-11_04:48:24.841609Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:ASC-CHARD_P_SW2 => 4 2025-06-11_04:48:24.966905Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:ASC-CHARD_P => ON: FM3, FM8 2025-06-11_04:48:24.967510Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:ASC-CHARD_P_GAIN => 208 2025-06-11_04:48:24.967807Z ISC_LOCK [LOWNOISE_ASC.run] timer['LoopShapeRamp'] = 5 2025-06-11_04:48:29.968096Z ISC_LOCK [LOWNOISE_ASC.run] timer['LoopShapeRamp'] done 2025-06-11_04:48:30.032683Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:ASC-DSOFT_Y_TRAMP => 5 2025-06-11_04:48:30.033138Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:ASC-DSOFT_Y_GAIN => 5 2025-06-11_04:48:30.033756Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:ASC-CSOFT_P_GAIN => 20 2025-06-11_04:48:30.034329Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:ASC-DSOFT_P_GAIN => 5 2025-06-11_04:48:30.034559Z ISC_LOCK [LOWNOISE_ASC.run] timer['LoopShapeRamp'] = 5 2025-06-11_04:48:35.034791Z ISC_LOCK [LOWNOISE_ASC.run] timer['LoopShapeRamp'] done 2025-06-11_04:48:35.092239Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:SUS-ITMX_M0_DAMP_Y_TRAMP => 10 2025-06-11_04:48:35.092760Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:SUS-ETMX_M0_DAMP_Y_TRAMP => 10 2025-06-11_04:48:35.093183Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:SUS-ITMY_M0_DAMP_Y_TRAMP => 10 2025-06-11_04:48:35.093992Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:SUS-ITMX_M0_DAMP_Y_GAIN => -0.5 2025-06-11_04:48:35.094272Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:SUS-ETMX_M0_DAMP_Y_GAIN => -0.5 2025-06-11_04:48:35.094742Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:SUS-ITMY_M0_DAMP_Y_GAIN => -0.5 2025-06-11_04:48:35.095133Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:SUS-ETMY_M0_DAMP_Y_GAIN => -0.5 2025-06-11_04:48:35.095352Z ISC_LOCK [LOWNOISE_ASC.run] timer['LoopShapeRamp'] = 10 2025-06-11_04:48:45.095610Z ISC_LOCK [LOWNOISE_ASC.run] timer['LoopShapeRamp'] done 2025-06-11_04:48:45.155739Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:SUS-SR2_M1_DAMP_P_GAIN => -0.2 2025-06-11_04:48:45.156105Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:SUS-SR2_M1_DAMP_Y_GAIN => -0.2 2025-06-11_04:48:45.156524Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:SUS-SR2_M1_DAMP_L_GAIN => -0.2 2025-06-11_04:48:45.156859Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:SUS-SR2_M1_DAMP_R_GAIN => -0.2 2025-06-11_04:48:45.157148Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:SUS-SR2_M1_DAMP_T_GAIN => -0.2 2025-06-11_04:48:45.157409Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:SUS-SR2_M1_DAMP_V_GAIN => -0.2 2025-06-11_04:48:45.157619Z ISC_LOCK [LOWNOISE_ASC.run] timer['LoopShapeRamp'] = 10 2025-06-11_04:48:55.157750Z ISC_LOCK [LOWNOISE_ASC.run] timer['LoopShapeRamp'] done 2025-06-11_04:48:55.218040Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:ASC-DHARD_P_SW1 => 1024 2025-06-11_04:48:55.469080Z ISC_LOCK [LOWNOISE_ASC.run] ezca: H1:ASC-DHARD_P => ON: FM4 2025-06-11_04:48:55.469331Z ISC_LOCK [LOWNOISE_ASC.run] timer['LoopShapeRamp'] = 5 2025-06-11_04:48:55.657977Z ISC_LOCK [LOWNOISE_ASC.run] Unstalling OMC_LOCK 2025-06-11_04:48:55.845135Z ISC_LOCK [LOWNOISE_ASC.run] Unstalling IMC_LOCK 2025-06-11_04:48:56.077743Z ISC_LOCK JUMP target: LOCKLOSS