Input: python3 /ligo/svncommon/SusSVN/sus/trunk/Common/PythonTools/satampswap_bestpossible_filterupdate_ECR_E2400330.py -o SR3 SRM BS PRM PR3 ITMX ITMY SR2 Output: All updated filters grabbed for SR3 SR3 M1 RT compensation filter updated to zpk([5.21],[0.0955],1,"n") SR3 M1 SD compensation filter updated to zpk([5.13],[0.094],1,"n") SR3 M1 T1 compensation filter updated to zpk([5.25],[0.096],1,"n") SR3 M1 T2 compensation filter updated to zpk([5.2],[0.095],1,"n") SR3 M1 T3 compensation filter updated to zpk([5.27],[0.096],1,"n") SR3 M1 LF compensation filter updated to zpk([5.16],[0.0945],1,"n") write /opt/rtcds/userapps/release/sus/h1/filterfiles/H1SUSSR3.txt Done writing updated filters for SR3 All updated filters grabbed for SRM SRM M1 T1 compensation filter updated to zpk([5.07],[0.093],1,"n") SRM M1 T2 compensation filter updated to zpk([5.2],[0.095],1,"n") SRM M1 T3 compensation filter updated to zpk([5.14],[0.094],1,"n") SRM M1 LF compensation filter updated to zpk([5.18],[0.095],1,"n") SRM M1 RT compensation filter updated to zpk([5.23],[0.096],1,"n") write /opt/rtcds/userapps/release/sus/h1/filterfiles/H1SUSSRM.txt Done writing updated filters for SRM All updated filters grabbed for BS BS M1 RT compensation filter updated to zpk([5.19],[0.096],1,"n") BS M1 SD compensation filter updated to zpk([5.11],[0.094],1,"n") BS M1 F1 compensation filter updated to zpk([5.19],[0.096],1,"n") BS M1 F2 compensation filter updated to zpk([5.23],[0.096],1,"n") BS M1 F3 compensation filter updated to zpk([5.26],[0.096],1,"n") BS M1 LF compensation filter updated to zpk([5.2],[0.095],1,"n") write /opt/rtcds/userapps/release/sus/h1/filterfiles/H1SUSBS.txt Done writing updated filters for BS All updated filters grabbed for PRM PRM M1 RT compensation filter updated to zpk([5.3],[0.0969],1,"n") PRM M1 SD compensation filter updated to zpk([5.22],[0.0955],1,"n") PRM M1 T1 compensation filter updated to zpk([5.3],[0.0969],1,"n") PRM M1 T2 compensation filter updated to zpk([5.2],[0.095],1,"n") PRM M1 T3 compensation filter updated to zpk([5.18],[0.095],1,"n") PRM M1 LF compensation filter updated to zpk([5.15],[0.094],1,"n") write /opt/rtcds/userapps/release/sus/h1/filterfiles/H1SUSPRM.txt Done writing updated filters for PRM All updated filters grabbed for PR3 PR3 M1 T1 compensation filter updated to zpk([5.35],[0.0975],1,"n") PR3 M1 T2 compensation filter updated to zpk([5.33],[0.0975],1,"n") PR3 M1 T3 compensation filter updated to zpk([5.19],[0.095],1,"n") PR3 M1 LF compensation filter updated to zpk([5.17],[0.0945],1,"n") PR3 M1 RT compensation filter updated to zpk([5.14],[0.094],1,"n") PR3 M1 SD compensation filter updated to zpk([5.24],[0.0955],1,"n") write /opt/rtcds/userapps/release/sus/h1/filterfiles/H1SUSPR3.txt Done writing updated filters for PR3 All updated filters grabbed for ITMX ITMX M0 F1 compensation filter updated to zpk([5.22],[0.0955],1,"n") ITMX M0 F2 compensation filter updated to zpk([5.35],[0.098],1,"n") ITMX M0 F3 compensation filter updated to zpk([5.18],[0.095],1,"n") ITMX M0 SD compensation filter updated to zpk([5.34],[0.0977],1,"n") ITMX M0 LF compensation filter updated to zpk([5.27],[0.0963],1,"n") ITMX M0 RT compensation filter updated to zpk([5.19],[0.095],1,"n") ITMX R0 LF compensation filter updated to zpk([5.26],[0.096],1,"n") ITMX R0 RT compensation filter updated to zpk([5.26],[0.096],1,"n") ITMX R0 F1 compensation filter updated to zpk([5.16],[0.0945],1,"n") ITMX R0 F2 compensation filter updated to zpk([5.26],[0.0963],1,"n") ITMX R0 F3 compensation filter updated to zpk([5.34],[0.0977],1,"n") ITMX R0 SD compensation filter updated to zpk([5.19],[0.095],1,"n") write /opt/rtcds/userapps/release/sus/h1/filterfiles/H1SUSITMX.txt Done writing updated filters for ITMX All updated filters grabbed for ITMY ITMY M0 F1 compensation filter updated to zpk([5.28],[0.0966],1,"n") ITMY M0 F2 compensation filter updated to zpk([5.25],[0.0961],1,"n") ITMY M0 F3 compensation filter updated to zpk([5.23],[0.096],1,"n") ITMY M0 SD compensation filter updated to zpk([5.18],[0.0951],1,"n") ITMY M0 LF compensation filter updated to zpk([5.18],[0.0947],1,"n") ITMY M0 RT compensation filter updated to zpk([5.3],[0.0969],1,"n") ITMY R0 LF compensation filter updated to zpk([5.29],[0.0969],1,"n") ITMY R0 RT compensation filter updated to zpk([5.28],[0.0965],1,"n") ITMY R0 F1 compensation filter updated to zpk([5.29],[0.0966],1,"n") ITMY R0 F2 compensation filter updated to zpk([5.23],[0.0957],1,"n") ITMY R0 F3 compensation filter updated to zpk([5.36],[0.0978],1,"n") ITMY R0 SD compensation filter updated to zpk([5.22],[0.0955],1,"n") write /opt/rtcds/userapps/release/sus/h1/filterfiles/H1SUSITMY.txt Done writing updated filters for ITMY All updated filters grabbed for SR2 SR2 M1 T1 compensation filter updated to zpk([5.22],[0.0955],1,"n") SR2 M1 T2 compensation filter updated to zpk([5.25],[0.096],1,"n") SR2 M1 T3 compensation filter updated to zpk([5.28],[0.0969],1,"n") SR2 M1 LF compensation filter updated to zpk([5.06],[0.0929],1,"n") SR2 M1 RT compensation filter updated to zpk([5.35],[0.0977],1,"n") SR2 M1 SD compensation filter updated to zpk([5.34],[0.0975],1,"n") write /opt/rtcds/userapps/release/sus/h1/filterfiles/H1SUSSR2.txt Done writing updated filters for SR2 All done! Remember to double check and load in the filters for ['SR3', 'SRM', 'BS', 'PRM', 'PR3', 'ITMX', 'ITMY', 'SR2']