oli.patane@cdsws25$ py satampswap_bestpossible_filterupdate_ECR_E2400330.py -o TMSX All updated filters grabbed for TMSX TMSX M1 RT compensation filter updated to zpk([5.11],[0.0939],1,"n") TMSX M1 SD compensation filter updated to zpk([5.25],[0.096],1,"n") TMSX M1 F1 compensation filter updated to zpk([5.28],[0.0965],1,"n") TMSX M1 F2 compensation filter updated to zpk([5.17],[0.0947],1,"n") TMSX M1 F3 compensation filter updated to zpk([5.25],[0.0961],1,"n") TMSX M1 LF compensation filter updated to zpk([5.31],[0.0969],1,"n") write /opt/rtcds/userapps/release/sus/h1/filterfiles/H1SUSTMSX.txt Done writing updated filters for TMSX All done! Remember to double check and load in the filters for ['TMSX'] oli.patane@cdsws25$ py satampswap_bestpossible_filterupdate_ECR_E2400330.py -o ETMX_M0_R0_L1 All updated filters grabbed for ETMX ETMX L1 UL compensation filter updated to zpk([5.11],[0.0933],1,"n") ETMX L1 LL compensation filter updated to zpk([5.29],[0.0969],1,"n") ETMX L1 UR compensation filter updated to zpk([5.29],[0.0969],1,"n") ETMX L1 LR compensation filter updated to zpk([5.17],[0.0943],1,"n") ETMX M0 F1 compensation filter updated to zpk([5.31],[0.0971],1,"n") ETMX M0 F2 compensation filter updated to zpk([5.33],[0.0973],1,"n") ETMX M0 F3 compensation filter updated to zpk([5.36],[0.0979],1,"n") ETMX M0 SD compensation filter updated to zpk([5.21],[0.0953],1,"n") ETMX M0 LF compensation filter updated to zpk([5.18],[0.0948],1,"n") ETMX M0 RT compensation filter updated to zpk([5.21],[0.0954],1,"n") ETMX R0 LF compensation filter updated to zpk([5.3],[0.0969],1,"n") ETMX R0 RT compensation filter updated to zpk([5.17],[0.0947],1,"n") ETMX R0 F1 compensation filter updated to zpk([5.18],[0.0947],1,"n") ETMX R0 F2 compensation filter updated to zpk([5.21],[0.0954],1,"n") ETMX R0 F3 compensation filter updated to zpk([5.3],[0.0969],1,"n") ETMX R0 SD compensation filter updated to zpk([5.18],[0.0948],1,"n") write /opt/rtcds/userapps/release/sus/h1/filterfiles/H1SUSETMX.txt Done writing updated filters for ETMX All done! Remember to double check and load in the filters for ['ETMX_M0_R0_L1'] oli.patane@cdsws25$ py satampswap_bestpossible_filterupdate_ECR_E2400330.py -o MC2 PR2 All updated filters grabbed for MC2 MC2 M1 RT compensation filter updated to zpk([5.33],[0.0975],1,"n") MC2 M1 SD compensation filter updated to zpk([5.18],[0.0947],1,"n") MC2 M1 T1 compensation filter updated to zpk([5.34],[0.0977],1,"n") MC2 M1 T2 compensation filter updated to zpk([5.23],[0.0956],1,"n") MC2 M1 T3 compensation filter updated to zpk([5.18],[0.0948],1,"n") MC2 M1 LF compensation filter updated to zpk([5.22],[0.0958],1,"n") write /opt/rtcds/userapps/release/sus/h1/filterfiles/H1SUSMC2.txt Done writing updated filters for MC2 All updated filters grabbed for PR2 PR2 M1 T3 compensation filter updated to zpk([5.37],[0.0979],1,"n") PR2 M1 LF compensation filter updated to zpk([5.29],[0.0967],1,"n") PR2 M1 RT compensation filter updated to zpk([5.24],[0.0958],1,"n") PR2 M1 SD compensation filter updated to zpk([5.31],[0.0969],1,"n") PR2 M1 T1 compensation filter updated to zpk([5.29],[0.0969],1,"n") PR2 M1 T2 compensation filter updated to zpk([5.25],[0.0962],1,"n") write /opt/rtcds/userapps/release/sus/h1/filterfiles/H1SUSPR2.txt Done writing updated filters for PR2 All done! Remember to double check and load in the filters for ['MC2', 'PR2']