$ py satampswap_bestpossible_filterupdate_ECR_E2400330.py -o ITMX_L1 ITMY_L1 BS_M2 PRM_M2_M3 SRM_M2_M3 All updated filters grabbed for ITMX ITMX L1 UL compensation filter updated to zpk([5.23],[0.0958],1,"n") ITMX L1 LL compensation filter updated to zpk([5.28],[0.0966],1,"n") ITMX L1 UR compensation filter updated to zpk([5.14],[0.0941],1,"n") ITMX L1 LR compensation filter updated to zpk([5.23],[0.0955],1,"n") write /opt/rtcds/userapps/release/sus/h1/filterfiles/H1SUSITMX.txt Done writing updated filters for ITMX All updated filters grabbed for ITMY ITMY L1 UL compensation filter updated to zpk([5.23],[0.0956],1,"n") ITMY L1 LL compensation filter updated to zpk([5.28],[0.0966],1,"n") ITMY L1 UR compensation filter updated to zpk([5.34],[0.0978],1,"n") ITMY L1 LR compensation filter updated to zpk([5.27],[0.0966],1,"n") write /opt/rtcds/userapps/release/sus/h1/filterfiles/H1SUSITMY.txt Done writing updated filters for ITMY All updated filters grabbed for BS BS M2 UL compensation filter updated to zpk([5.31],[0.097],1,"n") BS M2 LL compensation filter updated to zpk([5.33],[0.0975],1,"n") BS M2 UR compensation filter updated to zpk([5.3],[0.0967],1,"n") BS M2 LR compensation filter updated to zpk([5.22],[0.0955],1,"n") write /opt/rtcds/userapps/release/sus/h1/filterfiles/H1SUSBS.txt Done writing updated filters for BS All updated filters grabbed for PRM PRM M2 UL compensation filter updated to zpk([5.24],[0.0961],1,"n") PRM M2 LL compensation filter updated to zpk([5.18],[0.095],1,"n") PRM M2 UR compensation filter updated to zpk([5.24],[0.0961],1,"n") PRM M2 LR compensation filter updated to zpk([5.25],[0.0962],1,"n") PRM M3 UL compensation filter updated to zpk([5.22],[0.0956],1,"n") PRM M3 LL compensation filter updated to zpk([5.27],[0.0967],1,"n") PRM M3 UR compensation filter updated to zpk([5.21],[0.0955],1,"n") PRM M3 LR compensation filter updated to zpk([5.18],[0.095],1,"n") write /opt/rtcds/userapps/release/sus/h1/filterfiles/H1SUSPRM.txt Done writing updated filters for PRM All updated filters grabbed for SRM SRM M2 UL compensation filter updated to zpk([5.22],[0.0955],1,"n") SRM M2 LL compensation filter updated to zpk([5.33],[0.0975],1,"n") SRM M2 UR compensation filter updated to zpk([5.19],[0.0951],1,"n") SRM M2 LR compensation filter updated to zpk([5.2],[0.0955],1,"n") SRM M3 UL compensation filter updated to zpk([5.37],[0.0983],1,"n") SRM M3 LL compensation filter updated to zpk([5.23],[0.0959],1,"n") SRM M3 UR compensation filter updated to zpk([5.23],[0.0955],1,"n") SRM M3 LR compensation filter updated to zpk([5.24],[0.0957],1,"n") write /opt/rtcds/userapps/release/sus/h1/filterfiles/H1SUSSRM.txt Done writing updated filters for SRM All done! Remember to double check and load in the filters for ['ITMX_L1', 'ITMY_L1', 'BS_M2', 'PRM_M2_M3', 'SRM_M2_M3']