$ python3 satampswap_bestpossible_filterupdate_ECR_E2400330.py -o PR2_M2_M3 SR2_M2_M3 All updated filters grabbed for PR2 PR2 M2 UL compensation filter updated to zpk([5.22],[0.0956],1,"n") PR2 M2 LL compensation filter updated to zpk([5.28],[0.0967],1,"n") PR2 M2 UR compensation filter updated to zpk([5.34],[0.0978],1,"n") PR2 M2 LR compensation filter updated to zpk([5.3],[0.0969],1,"n") PR2 M3 UL compensation filter updated to zpk([5.22],[0.0957],1,"n") PR2 M3 LL compensation filter updated to zpk([5.17],[0.0949],1,"n") PR2 M3 UR compensation filter updated to zpk([5.33],[0.0977],1,"n") PR2 M3 LR compensation filter updated to zpk([5.16],[0.0946],1,"n") write /opt/rtcds/userapps/release/sus/h1/filterfiles/H1SUSPR2.txt Done writing updated filters for PR2 All updated filters grabbed for SR2 SR2 M2 UL compensation filter updated to zpk([5.24],[0.0961],1,"n") SR2 M2 LL compensation filter updated to zpk([5.27],[0.0965],1,"n") SR2 M2 UR compensation filter updated to zpk([5.23],[0.0961],1,"n") SR2 M2 LR compensation filter updated to zpk([5.26],[0.0963],1,"n") SR2 M3 UL compensation filter updated to zpk([5.27],[0.0964],1,"n") SR2 M3 LL compensation filter updated to zpk([5.21],[0.0954],1,"n") SR2 M3 UR compensation filter updated to zpk([5.22],[0.0955],1,"n") SR2 M3 LR compensation filter updated to zpk([5.26],[0.0964],1,"n") write /opt/rtcds/userapps/release/sus/h1/filterfiles/H1SUSSR2.txt Done writing updated filters for SR2 All done! Remember to double check and load in the filters for ['PR2_M2_M3', 'SR2_M2_M3']