python3 OSEMcalib_DAMPcompensation.py OSEMcalib_DAMPcomp_SRM.txt Updating compensation gains for SRM L Old: old_Ellip50 - FilterDesign(design='zpk([0+i*80.47360000000103;0-i*80.47360000000103;0+i*176.2019999999996;0-i*176.2019999999996],[18.21489999999932+i*23.93060000000564;18.21489999999932-i*23.93060000000564;5.264060000000052+i*49.68549999999985;5.264060000000052-i*49.68549999999985],0.8912509999997833,"n")', rate=16384.0) write /opt/rtcds/userapps/release/sus/h1/filterfiles/H1SUSSRM.txt New: x0.571 - FilterDesign(design='zpk([],[],0.571,"n")', rate=16384.0) T Old: old_Ellip50 - FilterDesign(design='zpk([0+i*80.47360000000103;0-i*80.47360000000103;0+i*176.2019999999996;0-i*176.2019999999996],[18.21489999999932+i*23.93060000000564;18.21489999999932-i*23.93060000000564;5.264060000000052+i*49.68549999999985;5.264060000000052-i*49.68549999999985],0.8912509999997833,"n")', rate=16384.0) write /opt/rtcds/userapps/release/sus/h1/filterfiles/H1SUSSRM.txt New: x0.656 - FilterDesign(design='zpk([],[],0.656,"n")', rate=16384.0) V Old: old_Ellip50 - FilterDesign(design='zpk([0+i*80.47360000000103;0-i*80.47360000000103;0+i*176.2019999999996;0-i*176.2019999999996],[18.21489999999932+i*23.93060000000564;18.21489999999932-i*23.93060000000564;5.264060000000052+i*49.68549999999985;5.264060000000052-i*49.68549999999985],0.8912509999997833,"n")', rate=16384.0) write /opt/rtcds/userapps/release/sus/h1/filterfiles/H1SUSSRM.txt New: x0.565 - FilterDesign(design='zpk([],[],0.565,"n")', rate=16384.0) R Old: old_normR - FilterDesign(design='zpk([],[],0.435,"n")', rate=16384.0) write /opt/rtcds/userapps/release/sus/h1/filterfiles/H1SUSSRM.txt New: x0.565 - FilterDesign(design='zpk([],[],0.565,"n")', rate=16384.0) P Old: old_gain_P - FilterDesign(design='zpk([],[],0.174,"n")gain(1)', rate=16384.0) write /opt/rtcds/userapps/release/sus/h1/filterfiles/H1SUSSRM.txt New: x0.561 - FilterDesign(design='zpk([],[],0.561,"n")', rate=16384.0) Y Old: old_normY - FilterDesign(design='zpk([1.000000000000236],[1.000000000000236],0.435,"n")gain(1)', rate=16384.0) write /opt/rtcds/userapps/release/sus/h1/filterfiles/H1SUSSRM.txt New: x0.571 - FilterDesign(design='zpk([],[],0.571,"n")', rate=16384.0)