Thorlabs Beam M² Data Export Date MM-DD-YYYY;07-09-2026 Time HH:MM:SS;08:45:04 Beam Profiler Model;BP209-VIS Serial Number;M00280451 Profiler Azimuth Angle ;[deg]; Wavelength;[nm];1064 Resolution;[µm];1.2 Beam Quality Measurement;M2 Beam Diameter Measure Method;Beam Width Clip (1/e²) * * * * * * * * * * After Lens Measurement Results * * * * * * * * * * Parameter;Unit;Result; M²x'; ;1.28; M²y'; ;1.25; Rayleigh Length X';mm;15.02; Rayleigh Length Y';mm;15.15; Beam Waist Diameter X';µm;161.22; Beam Waist Diameter Y';µm;160.20; Beam Waist Asymmetrie; ;0.99; Beam Waist Position X';mm;129.70; Beam Waist Position Y';mm;128.20; Astigmatism;mm;1.51; Relative Astigmatism; ;0.10; Divergence Angle X';deg;0.615; Divergence Angle Y';deg;0.606; Divergence Asymmetry;%;0.986; * * * * * * * * * * Original Waist Measurement Results * * * * * * * * * * Parameter;Unit;Result; M²x'; ;1.28; M²y'; ;1.25; Rayleigh Length X';mm;1467.61; Rayleigh Length Y';mm;1619.11; Beam Waist Diameter X';µm;1593.51; Beam Waist Diameter Y';µm;1656.35; Beam Waist Asymmetrie; ;1.04; Beam Waist Position X';mm;2316.75; Beam Waist Position Y';mm;2347.70; Astigmatism;mm;30.95; Relative Astigmatism; ;0.02; Divergence Angle X';deg;0.062; Divergence Angle Y';deg;0.059; Divergence Asymmetry;%;0.942; * * * * * * * * * * BEAM DIAMETERS * * * * * * * * * * Z;X';Y'; 200.00;776.96;779.49; 180.00;565.76;575.48; 160.00;359.35;371.88; 140.00;186.45;196.25; 127.79;161.93;157.79; 125.97;166.17;160.72; 124.16;173.80;166.20; 122.33;181.62;172.66; 120.52;190.86;180.43; 120.00;193.36;183.71; 118.70;202.17;191.05; 116.88;214.31;202.30; 100.00;358.58;341.16; 80.00;553.43;537.41; 60.00;761.43;736.85; 40.00;972.76;945.59; 20.00;1188.41;1153.61; 0.00;1403.70;1363.85;