"4395A REV1.12" "DATE: Apr 25 1994" "CHANNEL: 1" "MEASURE TYPE: A/R" "FORMAT TYPE: LOG MAG" "NUMBER of POINTS: 201" "SWEEP TIME: 886.8 ms" "SWEEP TYPE: LOG FREQ" "SOURCE POWER: -10 dBm" "IF BANDWIDTH: 1 kHz" "Frequency" "Data Trace Real" "Data Trace Imag" "Memory Trace Real" "Memory Trace Imag" 1.000000000000E+04 -2.947550E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.028531200000E+04 -2.947825E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.057062400000E+04 -2.951978E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.085593500000E+04 -2.955940E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.114124700000E+04 -2.958795E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.142655900000E+04 -2.961942E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.171187100000E+04 -2.963106E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.199718300000E+04 -2.965572E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.228249500000E+04 -2.965854E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.256780600000E+04 -2.968987E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.285311800000E+04 -2.969930E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.313843000000E+04 -2.974911E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.346852900000E+04 -2.974464E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.384786000000E+04 -2.978665E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.422719000000E+04 -2.978901E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.460652100000E+04 -2.979337E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.498585100000E+04 -2.983892E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.536518200000E+04 -2.984220E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.574451300000E+04 -2.985219E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.612384300000E+04 -2.986537E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.650317400000E+04 -2.985895E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.688250400000E+04 -2.986341E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.726183500000E+04 -2.987997E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.769553300000E+04 -2.991626E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.819391400000E+04 -2.989126E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.869229500000E+04 -2.990633E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.919067600000E+04 -2.991618E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.968905700000E+04 -2.994318E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.018743700000E+04 -2.993901E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.068581800000E+04 -2.994775E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.118419900000E+04 -2.995095E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.168258000000E+04 -2.994809E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.218096100000E+04 -2.997191E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.267934200000E+04 -2.996180E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.324915300000E+04 -2.997642E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.390394700000E+04 -2.997280E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.455874100000E+04 -2.997866E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.521353600000E+04 -2.998223E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.586833000000E+04 -2.998512E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.652312400000E+04 -2.999230E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.717791800000E+04 -2.999366E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.783271200000E+04 -2.998862E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.848750700000E+04 -3.000502E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.914230100000E+04 -2.999458E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.979709500000E+04 -3.000832E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.054573700000E+04 -3.000385E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.140603400000E+04 -3.001687E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.226633100000E+04 -3.003645E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.312662800000E+04 -3.002314E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.398692500000E+04 -3.003844E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.484722100000E+04 -3.003582E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.570751800000E+04 -3.004327E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.656781500000E+04 -3.003598E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.742811200000E+04 -3.004473E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.828840900000E+04 -3.004390E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.914870600000E+04 -3.007040E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.013230400000E+04 -3.008231E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.126259900000E+04 -3.007195E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.239289400000E+04 -3.008945E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.352318900000E+04 -3.009139E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.465348400000E+04 -3.009580E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.578377900000E+04 -3.012293E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.691407400000E+04 -3.013305E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.804436900000E+04 -3.015624E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.917466400000E+04 -3.017630E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.030495900000E+04 -3.020124E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.143525400000E+04 -3.021794E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.272754800000E+04 -3.024202E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.421257800000E+04 -3.026373E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.569760900000E+04 -3.029058E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.718263900000E+04 -3.034162E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.866766900000E+04 -3.040576E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.015269900000E+04 -3.044331E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.163773000000E+04 -3.048639E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.312276000000E+04 -3.055028E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.460779000000E+04 -3.059889E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.609282100000E+04 -3.067821E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.757785100000E+04 -3.074205E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.927572100000E+04 -3.084360E+01 0.000000E+00 0.000000E+00 0.000000E+00 7.122681800000E+04 -3.093483E+01 0.000000E+00 0.000000E+00 0.000000E+00 7.317791400000E+04 -3.104332E+01 0.000000E+00 0.000000E+00 0.000000E+00 7.512901100000E+04 -3.116698E+01 0.000000E+00 0.000000E+00 0.000000E+00 7.708010800000E+04 -3.131353E+01 0.000000E+00 0.000000E+00 0.000000E+00 7.903120500000E+04 -3.146378E+01 0.000000E+00 0.000000E+00 0.000000E+00 8.098230100000E+04 -3.158912E+01 0.000000E+00 0.000000E+00 0.000000E+00 8.293339800000E+04 -3.176925E+01 0.000000E+00 0.000000E+00 0.000000E+00 8.488449500000E+04 -3.194168E+01 0.000000E+00 0.000000E+00 0.000000E+00 8.683559100000E+04 -3.209974E+01 0.000000E+00 0.000000E+00 0.000000E+00 8.878668800000E+04 -3.226879E+01 0.000000E+00 0.000000E+00 0.000000E+00 9.101742300000E+04 -3.249934E+01 0.000000E+00 0.000000E+00 0.000000E+00 9.358085800000E+04 -3.272134E+01 0.000000E+00 0.000000E+00 0.000000E+00 9.614429300000E+04 -3.301707E+01 0.000000E+00 0.000000E+00 0.000000E+00 9.870772800000E+04 -3.330610E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.012711630000E+05 -3.359666E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.038345980000E+05 -3.392220E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.063980320000E+05 -3.421121E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.089614670000E+05 -3.453323E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.115249020000E+05 -3.484645E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.140883370000E+05 -3.519644E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.166517720000E+05 -3.554100E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.195826070000E+05 -3.589729E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.229944410000E+05 -3.636243E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.264062740000E+05 -3.683027E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.298181080000E+05 -3.729431E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.332299410000E+05 -3.774683E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.366417750000E+05 -3.821923E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.400536080000E+05 -3.868547E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.434654420000E+05 -3.912774E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.468772750000E+05 -3.958916E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.502891090000E+05 -4.004750E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.537009420000E+05 -4.048788E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.571127760000E+05 -4.092305E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.610601800000E+05 -4.147079E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.655963150000E+05 -4.196661E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.701324490000E+05 -4.251466E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.746685840000E+05 -4.306049E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.792047180000E+05 -4.356590E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.837408530000E+05 -4.405122E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.882769870000E+05 -4.450969E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.928131220000E+05 -4.501809E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.973492560000E+05 -4.557753E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.018853910000E+05 -4.621416E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.064215250000E+05 -4.748022E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.116077960000E+05 -4.867757E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.175675650000E+05 -5.017498E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.235273330000E+05 -5.162104E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.294871020000E+05 -5.252655E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.354468710000E+05 -5.361744E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.414066390000E+05 -5.410691E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.473664080000E+05 -5.475147E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.533261770000E+05 -5.449436E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.592859460000E+05 -5.413340E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.652457140000E+05 -5.360040E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.712054830000E+05 -5.298577E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.780194280000E+05 -5.242316E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.858496290000E+05 -5.177464E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.936798290000E+05 -5.113924E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.015100300000E+05 -5.063185E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.093402300000E+05 -5.006850E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.171704310000E+05 -4.956618E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.250006320000E+05 -4.918436E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.328308320000E+05 -4.884727E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.406610330000E+05 -4.855703E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.484912330000E+05 -4.817609E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.563214340000E+05 -4.784002E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.652738880000E+05 -4.761814E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.755615430000E+05 -4.728636E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.858491970000E+05 -4.707565E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.961368520000E+05 -4.694494E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.064245060000E+05 -4.670222E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.167121610000E+05 -4.648359E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.269998150000E+05 -4.635088E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.372874700000E+05 -4.623993E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.475751240000E+05 -4.608326E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.578627790000E+05 -4.594231E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.681504330000E+05 -4.592318E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.799125520000E+05 -4.580075E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.934289150000E+05 -4.569762E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.069452780000E+05 -4.563389E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.204616420000E+05 -4.560812E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.339780050000E+05 -4.547830E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.474943680000E+05 -4.537413E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.610107310000E+05 -4.525539E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.745270940000E+05 -4.526956E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.880434580000E+05 -4.512894E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.015598210000E+05 -4.516162E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.150761840000E+05 -4.507088E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.305297630000E+05 -4.501007E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.482881430000E+05 -4.494765E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.660465220000E+05 -4.494201E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.838049020000E+05 -4.496618E+01 0.000000E+00 0.000000E+00 0.000000E+00 7.015632810000E+05 -4.491024E+01 0.000000E+00 0.000000E+00 0.000000E+00 7.193216610000E+05 -4.480489E+01 0.000000E+00 0.000000E+00 0.000000E+00 7.370800400000E+05 -4.479359E+01 0.000000E+00 0.000000E+00 0.000000E+00 7.548384200000E+05 -4.483385E+01 0.000000E+00 0.000000E+00 0.000000E+00 7.725967990000E+05 -4.476736E+01 0.000000E+00 0.000000E+00 0.000000E+00 7.903551790000E+05 -4.473844E+01 0.000000E+00 0.000000E+00 0.000000E+00 8.081135580000E+05 -4.474102E+01 0.000000E+00 0.000000E+00 0.000000E+00 8.284171350000E+05 -4.475420E+01 0.000000E+00 0.000000E+00 0.000000E+00 8.517488580000E+05 -4.468670E+01 0.000000E+00 0.000000E+00 0.000000E+00 8.750805810000E+05 -4.480299E+01 0.000000E+00 0.000000E+00 0.000000E+00 8.984123050000E+05 -4.480736E+01 0.000000E+00 0.000000E+00 0.000000E+00 9.217440280000E+05 -4.474902E+01 0.000000E+00 0.000000E+00 0.000000E+00 9.450757510000E+05 -4.484608E+01 0.000000E+00 0.000000E+00 0.000000E+00 9.684074740000E+05 -4.478698E+01 0.000000E+00 0.000000E+00 0.000000E+00 9.917391970000E+05 -4.483662E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.015070921000E+06 -4.509447E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.038402644000E+06 -4.516356E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.061734367000E+06 -4.525526E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.088410080000E+06 -4.523470E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.119463709000E+06 -4.520752E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.150517338000E+06 -4.525282E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.181570967000E+06 -4.515479E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.212624596000E+06 -4.518638E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.243678225000E+06 -4.512794E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.274731855000E+06 -4.525855E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.305785484000E+06 -4.519073E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.336839113000E+06 -4.516765E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.367892742000E+06 -4.522607E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.398946371000E+06 -4.522039E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.430000000000E+06 -4.528556E+01 0.000000E+00 0.000000E+00 0.000000E+00 "CHANNEL: 2" "MEASURE TYPE: A/R" "FORMAT TYPE: PHASE (DEG)" "NUMBER of POINTS: 201" "SWEEP TIME: 886.8 ms" "SWEEP TYPE: LOG FREQ" "SOURCE POWER: -10 dBm" "IF BANDWIDTH: 1 kHz" "Frequency" "Data Trace Real" "Data Trace Imag" "Memory Trace Real" "Memory Trace Imag" 1.000000000000E+04 -2.993108E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.028531200000E+04 -2.958949E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.057062400000E+04 -2.932718E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.085593500000E+04 -2.920263E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.114124700000E+04 -2.898194E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.142655900000E+04 -2.862983E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.171187100000E+04 -2.851462E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.199718300000E+04 -2.833531E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.228249500000E+04 -2.830075E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.256780600000E+04 -2.809920E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.285311800000E+04 -2.802657E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.313843000000E+04 -2.775290E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.346852900000E+04 -2.753013E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.384786000000E+04 -2.762298E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.422719000000E+04 -2.735682E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.460652100000E+04 -2.722768E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.498585100000E+04 -2.735194E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.536518200000E+04 -2.719933E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.574451300000E+04 -2.729267E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.612384300000E+04 -2.736381E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.650317400000E+04 -2.727054E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.688250400000E+04 -2.733335E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.726183500000E+04 -2.713953E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.769553300000E+04 -2.749989E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.819391400000E+04 -2.732823E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.869229500000E+04 -2.764337E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.919067600000E+04 -2.767507E+01 0.000000E+00 0.000000E+00 0.000000E+00 1.968905700000E+04 -2.798607E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.018743700000E+04 -2.797394E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.068581800000E+04 -2.821047E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.118419900000E+04 -2.827036E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.168258000000E+04 -2.855658E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.218096100000E+04 -2.878639E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.267934200000E+04 -2.898685E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.324915300000E+04 -2.941123E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.390394700000E+04 -2.955779E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.455874100000E+04 -2.993050E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.521353600000E+04 -3.045282E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.586833000000E+04 -3.090819E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.652312400000E+04 -3.132797E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.717791800000E+04 -3.169122E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.783271200000E+04 -3.211823E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.848750700000E+04 -3.256570E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.914230100000E+04 -3.287151E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.979709500000E+04 -3.335414E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.054573700000E+04 -3.384095E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.140603400000E+04 -3.463918E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.226633100000E+04 -3.512393E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.312662800000E+04 -3.588842E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.398692500000E+04 -3.666135E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.484722100000E+04 -3.719710E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.570751800000E+04 -3.788351E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.656781500000E+04 -3.861329E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.742811200000E+04 -3.920443E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.828840900000E+04 -4.003350E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.914870600000E+04 -4.078534E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.013230400000E+04 -4.163606E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.126259900000E+04 -4.258382E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.239289400000E+04 -4.371291E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.352318900000E+04 -4.471428E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.465348400000E+04 -4.571624E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.578377900000E+04 -4.683350E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.691407400000E+04 -4.794804E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.804436900000E+04 -4.900887E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.917466400000E+04 -5.003600E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.030495900000E+04 -5.132335E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.143525400000E+04 -5.251501E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.272754800000E+04 -5.381855E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.421257800000E+04 -5.542904E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.569760900000E+04 -5.697651E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.718263900000E+04 -5.850618E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.866766900000E+04 -6.017268E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.015269900000E+04 -6.189051E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.163773000000E+04 -6.360378E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.312276000000E+04 -6.517182E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.460779000000E+04 -6.690305E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.609282100000E+04 -6.869015E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.757785100000E+04 -7.035468E+01 0.000000E+00 0.000000E+00 0.000000E+00 6.927572100000E+04 -7.240592E+01 0.000000E+00 0.000000E+00 0.000000E+00 7.122681800000E+04 -7.466601E+01 0.000000E+00 0.000000E+00 0.000000E+00 7.317791400000E+04 -7.697312E+01 0.000000E+00 0.000000E+00 0.000000E+00 7.512901100000E+04 -7.932111E+01 0.000000E+00 0.000000E+00 0.000000E+00 7.708010800000E+04 -8.171431E+01 0.000000E+00 0.000000E+00 0.000000E+00 7.903120500000E+04 -8.413901E+01 0.000000E+00 0.000000E+00 0.000000E+00 8.098230100000E+04 -8.644977E+01 0.000000E+00 0.000000E+00 0.000000E+00 8.293339800000E+04 -8.881786E+01 0.000000E+00 0.000000E+00 0.000000E+00 8.488449500000E+04 -9.109904E+01 0.000000E+00 0.000000E+00 0.000000E+00 8.683559100000E+04 -9.341862E+01 0.000000E+00 0.000000E+00 0.000000E+00 8.878668800000E+04 -9.572935E+01 0.000000E+00 0.000000E+00 0.000000E+00 9.101742300000E+04 -9.840454E+01 0.000000E+00 0.000000E+00 0.000000E+00 9.358085800000E+04 -1.013195E+02 0.000000E+00 0.000000E+00 0.000000E+00 9.614429300000E+04 -1.044380E+02 0.000000E+00 0.000000E+00 0.000000E+00 9.870772800000E+04 -1.074305E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.012711630000E+05 -1.103777E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.038345980000E+05 -1.131307E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.063980320000E+05 -1.160260E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.089614670000E+05 -1.190874E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.115249020000E+05 -1.217584E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.140883370000E+05 -1.246464E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.166517720000E+05 -1.272409E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.195826070000E+05 -1.303901E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.229944410000E+05 -1.340125E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.264062740000E+05 -1.377133E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.298181080000E+05 -1.410702E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.332299410000E+05 -1.444962E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.366417750000E+05 -1.481971E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.400536080000E+05 -1.514767E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.434654420000E+05 -1.552215E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.468772750000E+05 -1.588739E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.502891090000E+05 -1.621417E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.537009420000E+05 -1.656923E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.571127760000E+05 -1.692920E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.610601800000E+05 -1.734044E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.655963150000E+05 -1.782746E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.701324490000E+05 1.765487E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.746685840000E+05 1.722230E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.792047180000E+05 1.666668E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.837408530000E+05 1.623272E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.882769870000E+05 1.568925E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.928131220000E+05 1.511455E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.973492560000E+05 1.460987E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.018853910000E+05 1.398358E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.064215250000E+05 1.338356E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.116077960000E+05 1.278057E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.175675650000E+05 1.181281E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.235273330000E+05 1.081663E+02 0.000000E+00 0.000000E+00 0.000000E+00 2.294871020000E+05 9.619871E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.354468710000E+05 8.377495E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.414066390000E+05 6.912460E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.473664080000E+05 5.616936E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.533261770000E+05 4.375974E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.592859460000E+05 3.175886E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.652457140000E+05 2.199541E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.712054830000E+05 1.300073E+01 0.000000E+00 0.000000E+00 0.000000E+00 2.780194280000E+05 5.886056E+00 0.000000E+00 0.000000E+00 0.000000E+00 2.858496290000E+05 -1.253104E+00 0.000000E+00 0.000000E+00 0.000000E+00 2.936798290000E+05 -7.550137E+00 0.000000E+00 0.000000E+00 0.000000E+00 3.015100300000E+05 -1.314469E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.093402300000E+05 -1.809697E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.171704310000E+05 -2.296747E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.250006320000E+05 -2.709540E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.328308320000E+05 -2.964753E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.406610330000E+05 -3.358196E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.484912330000E+05 -3.671456E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.563214340000E+05 -3.977735E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.652738880000E+05 -4.350243E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.755615430000E+05 -4.663372E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.858491970000E+05 -5.057345E+01 0.000000E+00 0.000000E+00 0.000000E+00 3.961368520000E+05 -5.355956E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.064245060000E+05 -5.712404E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.167121610000E+05 -6.035780E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.269998150000E+05 -6.284019E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.372874700000E+05 -6.628784E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.475751240000E+05 -6.911639E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.578627790000E+05 -7.113071E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.681504330000E+05 -7.430322E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.799125520000E+05 -7.662973E+01 0.000000E+00 0.000000E+00 0.000000E+00 4.934289150000E+05 -8.042225E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.069452780000E+05 -8.288145E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.204616420000E+05 -8.612061E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.339780050000E+05 -8.901570E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.474943680000E+05 -9.219182E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.610107310000E+05 -9.471871E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.745270940000E+05 -9.794025E+01 0.000000E+00 0.000000E+00 0.000000E+00 5.880434580000E+05 -1.008746E+02 0.000000E+00 0.000000E+00 0.000000E+00 6.015598210000E+05 -1.032759E+02 0.000000E+00 0.000000E+00 0.000000E+00 6.150761840000E+05 -1.064363E+02 0.000000E+00 0.000000E+00 0.000000E+00 6.305297630000E+05 -1.093291E+02 0.000000E+00 0.000000E+00 0.000000E+00 6.482881430000E+05 -1.128519E+02 0.000000E+00 0.000000E+00 0.000000E+00 6.660465220000E+05 -1.168463E+02 0.000000E+00 0.000000E+00 0.000000E+00 6.838049020000E+05 -1.201431E+02 0.000000E+00 0.000000E+00 0.000000E+00 7.015632810000E+05 -1.235662E+02 0.000000E+00 0.000000E+00 0.000000E+00 7.193216610000E+05 -1.275440E+02 0.000000E+00 0.000000E+00 0.000000E+00 7.370800400000E+05 -1.306199E+02 0.000000E+00 0.000000E+00 0.000000E+00 7.548384200000E+05 -1.340984E+02 0.000000E+00 0.000000E+00 0.000000E+00 7.725967990000E+05 -1.372363E+02 0.000000E+00 0.000000E+00 0.000000E+00 7.903551790000E+05 -1.407071E+02 0.000000E+00 0.000000E+00 0.000000E+00 8.081135580000E+05 -1.440959E+02 0.000000E+00 0.000000E+00 0.000000E+00 8.284171350000E+05 -1.474561E+02 0.000000E+00 0.000000E+00 0.000000E+00 8.517488580000E+05 -1.518402E+02 0.000000E+00 0.000000E+00 0.000000E+00 8.750805810000E+05 -1.556199E+02 0.000000E+00 0.000000E+00 0.000000E+00 8.984123050000E+05 -1.591810E+02 0.000000E+00 0.000000E+00 0.000000E+00 9.217440280000E+05 -1.625994E+02 0.000000E+00 0.000000E+00 0.000000E+00 9.450757510000E+05 -1.657948E+02 0.000000E+00 0.000000E+00 0.000000E+00 9.684074740000E+05 -1.696557E+02 0.000000E+00 0.000000E+00 0.000000E+00 9.917391970000E+05 -1.728794E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.015070921000E+06 -1.762820E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.038402644000E+06 -1.786000E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.061734367000E+06 1.786568E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.088410080000E+06 1.753410E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.119463709000E+06 1.721587E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.150517338000E+06 1.683269E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.181570967000E+06 1.651853E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.212624596000E+06 1.612864E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.243678225000E+06 1.577475E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.274731855000E+06 1.533958E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.305785484000E+06 1.496215E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.336839113000E+06 1.454581E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.367892742000E+06 1.412542E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.398946371000E+06 1.379157E+02 0.000000E+00 0.000000E+00 0.000000E+00 1.430000000000E+06 1.339051E+02 0.000000E+00 0.000000E+00 0.000000E+00